135-0234 rev C 01/10/2020 Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx) Installation Set

Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

135-0234 rev C 01/10/2020

Nevco

10mm/16mm/20mm/32mm

Message Centers

(x6xx)

Installation Set

Page 2: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

1/10/2020 135-0228Rev. C

Nevco Message Center

Installation Manual

Retain this manual in your permanent file.

Page 3: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

Table of Contents

INSTALLATION INSTRUCTIONS .............................................................................................. 1

UNPACKING THE EQUIPMENT ....................................................................................................... 1 MESSAGE CENTER MOUNTING ..................................................................................................... 1 MESSAGE CENTER CONNECTIONS ............................................................................................. 4

Ethernet Cables .................................................................................................................. 5 . SOFTWARE SETUP ....................................................................................................................... 6

Computer is Not connected to existing Network ................................................................... 6 Computer is Connected to an existing Network .................................................................... 7

INSTALLER’S TROUBLESHOOTING GUIDE ....................................................................... 8

GLOSSARY .................................................................................................................................. 10

Page 4: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

135-0228 Rev. C Page 1 1

Installation Instructions

Installation consists of four steps, Unpacking the Equipment, Message Center mounting, Connections, and

Software setup. Be sure to read and understand all of the instructions before installing the equipment. Consult

the “installer’s trouble shooting guide” following this section for verifications each step has been installed and

is working correctly.

1. Unpacking the Equipment

Inspect the shipping container for damage. If any damage can be seen, contact the carrier

immediately.

Carefully remove all equipment from its packing carton. Do not pry against the message center

in any way.

2. Message Center Mounting

Nevco strongly encourages you to check local codes before beginning the installation. You may

wish to contact a local architect, contractor, or sign installer for assistance. Your Nevco Sales

Representative may be able to assist you in finding professional installers who are familiar with

this type of equipment.

Always use good mechanical practices when mounting the message center.

Use plated fastening devices to prevent rust or corrosion.

Mount the optional temperature sensor / photocell out of direct sunlight to avoid an elevated

reading.

Mount the two wireless devices (if present) in clear line of sight with each other.

For indoor installations, install angle iron on wall or other structure prior to attaching the

message center. Angle iron and attachments (bolts, washers, etc.) are not included. See

installation drawings for approximate distance between angle iron supports.

For outdoor installations, install tubing laterals on columns prior to installing the message center.

Laterals should be welded or bolted to steel columns. Laterals and attachments (bolts, washers,

nuts, etc.) are not included. See installation drawings for approximate distance between lateral

supports. Brackets on message centers can be welded or bolted to the laterals.

Each message center comes with 2 lifting points on the top of the unit. When using the lifting

points, make sure cables are vertical and not putting an undue horizontal force on the lifting

points. Use of a spreader bar is recommended when using the lifting points.

For multi-section message centers, make sure the cabinets and supports line up vertically and

horizontally. Cabinets should be installed as tight as possible to each other. Where the sections

join together, a bracket shall be installed at the top and bottom. Half of the bracket should

support each section.

Your Message Center was designed so that it can be mounted in a variety of ways. Please

examine the installation drawings to determine the best mounting method for your location.

Access to all internal components is through the front, accessibility to the rear of the cabinet is

NOT necessary. The standard mounting brackets are shipped on the Message Center in a

“retracted” position and must be unbolted and rotated 180°, then reattached with the same bolts

before starting the installation.

Page 5: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

135-0228 Rev. C Page 2 2

Additional Suggested Mounting Methods

Indoor Mount

Outdoor Mount on Laterals

Page 6: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

135-0228 Rev. C Page 3 3

Standalone Indoor 10mm Message Centers:

Indoor 10mm Message Center Mounted With Other Product:

Note: Please see installation drawings for more details and options.

Page 7: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

135-0228 Rev. C Page 4 4

3. Message Center Connections

Each message center, whether it is made up of two cabinets end to end, or two cabinets back to back

(double sided), or a single cabinet, requires that power and signal be supplied to each cabinet by the

installer. All internal connections have been completed and tested at the factory.

Both power and data should enter each message center cabinet at its lower left corner as viewed from

the front. An access panel is provided for these connections. The “signal in”

conduit attaches to the panel and a junction box is mounted on the panel for

power connections. Similar access panels are installed on the back and

bottom of the cabinet. All three panels are interchangeable so that the one

with the junction box can be located in the most favorable position. The panel

with the junction box can be moved to either of the other locations without

disconnecting any cables inside the message center.

Be sure to reattach all panels so as to maintain a weather tight seal.

The optional temperature and light sensors should be mounted near this location and need to be

connected to a cable inside the message center behind the access panel.

At the lower right corner of the message center as viewed from the front is a similar

arrangement for the “signal out” if needed. Used for side 2 of a two sided message center,

and message centers made up of two cabinets mounted end to end.

Note: Please see installation drawings for more details.

Page 8: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

135-0228 Rev. C Page 5 5

Electrical Connections

Refer to installation prints for illustration of electrical

connections.

Power Service This sign is intended to be installed in

accordance with the requirements of Article 600

of the National Electrical Code and/or other

applicable local codes. This includes proper

grounding and bonding of the sign.

Consult table 1 for power requirements for your message

center model. Provide for a 30% safety factor to guard

against tripping of the circuit breaker under low line

conditions.

*Denoted values require 2 separate 20A breakers.

Be sure to include any lighted signs, and account for

double sided displays when sizing the supply wiring

necessary to support the circuit load.

A disconnect switch should be lockable or within sight of

the sign per NEC article 600.

Ethernet Cables

In a wired configuration, connect from the PC to the

controller with a crossover connection.

If rigid EMT is used, use ¾” rain-tight conduit fittings to

avoid cutting the ends off included pre-made cables.

WARNING! Take care not to reverse the connections on

the POE adapter as this will damage the controller. Refer to installation print and color coding for details.

Cabinet Dimensions

Current @ 120VAC

Current @ 240VAC

20mm Color

3x8 5.2 2.6

3x10 6.6 3.3

3x12 8.1 4.1

3x16 Left 5.2 2.6

3x16 Right 5.9 3.0

4x8 7.2 3.6

4x10 9.3 4.7

4x12 Left 5.2 2.6

4x12 Right 6.2 3.1

4x16 Left 7.2 3.6

4x16 Right 8.3 4.1

16mm Color

3x8 7.5 3.8

3x10 9.0 4.5

3x12 11.3 5.6

3x16 Left 7.5 3.8

3x16 Right 7.5 3.8

4x8 10.0 5.0

4x10 12.0 6.0

4x12 Left 7.0 3.5

4x12 Right 8.0 4.0

4x16 Left 10.0 5.0

4x16 Right 10.0 5.0

10mm Color

Outdoor

3x8 12.2 6.1

3x10 15.6 7.8

3x12 19.1 9.5

3x16 Left 12.2 6.1

3x16 Right 13.9 6.9

4x8 16.2 8.1

4x10 20.8 10.4

4x12 Left 11.6 5.8

4x12 Right 13.9 6.9

4x16 Left 16.2 8.1

4x16 Right 18.5 9.3

10mm Color Indoor

3x8 5.8 2.9

3x10 7.0 3.5

4x8 7.8 3.9

4x10 9.3 4.7

PC Wireless

AP

Wireless

Bridge POE Sign Sign Side 2 2.4Ghz

Wireless

T R

if double sided Rain-tight Box

POE

PC Sign Side 2 T R

if double sided Less than 325’

Sign

Figure 2 – Wired Configuration Ethernet

PC Sign Sign Side 2 T R

if double sided Rain-tight Box

Fiber 325’ – 1.2 Miles

Media Converter Media Converter

Figure 3 – Wired Configuration Fiber Optic

Figure 1 – Wireless Configuration

The diagrams below show Ethernet connections:

Ethernet Straight through cable

Ethernet Crossover cable

Page 9: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

135-0228 Rev. C Page 6 6

4. Software Setup

The message center can be connected to a dedicated computer for setting up new messages, or integrated as part

of an existing computer network. The system is shipped in the first case as described in “Not connected to

existing Network”.

Computer is Not connected to existing Network

The message center controller and wireless equipment (optional) are pre-configured to a default network

configuration. The IP address of the controller is set to 192.168.0.210. Wireless Bridge and AP are

192.168.0.211 and 192.168.0.212 respectively.

When the software is installed, the default projects are configured to talk to the default controller IP address.

Follow these steps to set the controlling PC’s IP address to one that can communicate with the message

center.

1. Click the start button and select Control Panel. Double click Network Connections. Double click your

network card or “Lan Connection”. On Win XP select properties. You will see the window on the left.

Select Internet Protocol (TCP/IP) and click Properties. You will see the window on the right.

2. Click the Radio Button “Use the following IP address” and enter 192.168.0.10 and the subnet mask

255.255.255.0 and click ok on each window. You may be prompted to insert your Win98/2000 CD.

3. When you open Nevco Composer™, the button in the lower right hand corner of the screen should say

“Update Message Center” showing that you are connected. (Be sure the license key is in the USB port

and the LED is on)

4. Consult the Nevco Composer™ user’s manual for troubleshooting.

If you are using a laptop, make sure to turn off the wireless LAN in the laptop (if present). This can be done

on most laptops by pressing a button in the area above the keyboard that looks like an antenna.

Page 10: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

135-0228 Rev. C Page 7 7

Computer is Connected to an existing Network

The message center controller and wireless equipment (optional) are pre-configured to a default network

configuration. The IP address of the controller is set to 192.168.0.210. Wireless Bridge and AP are

192.168.0.211 and 192.168.0.212 respectively.

The steps to change the IP address on each of the devices are explained in detail in the user’s manuals for

each device. Consult these manuals for more information. The wireless devices support DHCP, but the

message center’s IP address must be static. To integrate the equipment into your existing network, in this

order you must change the IP address on a computer, use that computer to change the message center IP

address, change the outdoor bridge IP address, and then change the Access Point IP address. Follow these

steps:

1. Connect the access point to the LAN with a straight through Ethernet cable. The unit is shipped with a

crossover cable for connecting directly to a PC.

2. Change a PC on the network’s IP address as instructed in “Not connected to an existing Network”

above.

3. Change the Message Center’s IP address by following these steps.

a. Install Nevco Composer™ on the Computer. Be sure to plug the license key into the USB port.

b. Enter “Password” as instructed in the manual. As long as the password remains “Password” you

will be prompted to change it each time the program is loaded.

c. Go to Message Center=>Configure Password and Message Center

d. Enter your current password and click connect on the right hand side of the window.

e. Enter the new IP address and subnet mask and click Update.

4. Change the Outdoor wireless client’s IP address by following these steps.

a. Open internet explorer and in the Address Bar type 192.168.0.211

b. Refer to the sticker in your user’s manual for the username and password.

c. A web page called Wireless Client Bridge will come up. Click on “TCP/IP Settings” and select

“LAN Interface”.

d. Change the network settings as necessary to fit your network topology and click “Apply

Changes”.

e. You may also want to change the wireless settings to suit your own security needs. Be sure to

change the Access Point to match in the next section.

5. Change the Access Point’s IP address by following these steps.

a. Open internet explorer and in the Address Bar type 192.168.0.212

b. Refer to the sticker in your user’s manual for the username and password.

c. A web page called Wireless LAN Access Point will come up.

d. Follow the same steps as 4, steps c - e. Make sure any security settings changed on the Client

Bridge match settings on the Access point.

6. You may now change your PC’s IP address back to its original configuration. Test the new

configuration by opening Nevco Composer™, going to Project=>Configure, enter the new IP address of

the message center and click “OK”. The status at the bottom of the screen should now be “Display

Connection = Ethernet”.

“Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at this own expense.”

Page 11: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

135-0228 Rev. C Page 8 8

PC POE

Rain-tight Box

If Outdoors

J G F

Power Power

J E

POE Wireless

AP

Wireless

Bridge

2.4Ghz

Wireless

H

C

Ethernet In

MESSAGE CENTER

B

Power In

Temperature & Light

Sensors

A

D

Ethernet Out

To side 2 (if applicable)

K

INSTALLER’S TROUBLESHOOTING GUIDE

The figure below labels the connections made by the installer from A – K. The chart below lists the problem that can be identified should each connection be faulty. Should a problem arise on any one component, consult the trouble shooting guide specific to that device.

.Note: All connections inside the Message Center have been made at the NEVCO Factory. Each Message Center requires Signal from the controlling PC. Each Message Center also requires Power (see Table 1).

Note: For double sided and/or double cabinet message centers. The input signal for subsequent cabinets comes from the output of the previous cabinet. A separate power circuit is required for each cabinet.

Page 12: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

135-0228 Rev. C Page 9 9

If the problem persists please contact the Nevco Service Department.

800-851-4040

Situation Symptom Connection Solution

The message

Center is not

displaying a

message

The fans on ALL power supplies are

running

C,D Replace crossover cable

In Composer, check the scheduling for the Project, then

click the button to send the project to message center

The fans on ALL power supplies are not

running

B

Check Power Switch on disconnect box inside message

center

Check connections in disconnect box (power hookup)

Check branch circuit; was there a photocell on an existing

sign install?

On a double sided Message

Center, One side is displaying the

message, the other is not

K,c Ensure an Ethernet straight through cable has been used, is

making a good connection at both ends.

“DSP” LED on controller IS

blinking, but the CASCAN card

has no LED’s blinking rapidly

(like DSP on the controller).

D Ensure an Ethernet crossover cable has been used, is

making a good connection at both ends.

I cannot

communicate

with the

message

center

No Red Power LED lit on

Wireless Bridge POE. E

Check branch circuit and power at the receptacle. Adapter

has LED indicator

No Red Power LED lit on

Wireless Access Point POE. J

Check branch circuit and power at the receptacle. Adapter

has LED indicator

LAN LED on Controller not ON

solid

D Ensure an Ethernet crossover cable has been used and is

making a good connection at both ends

F Ensure an Ethernet straight through cable has been used and

is making a good connection at both ends.

LAN LED on PC Ethernet port

not ON, or PC says “network

unplugged”, “not connected”.

H Ensure an Ethernet straight through cable has been used and

is making a good connection at both ends.

I

Ensure an Ethernet crossover cable has been used and is

making a good connection at both ends. Check to see that

the network interface is enabled and follow the procedure in

“Not connected to existing Network above.

User’s manual on CD with

wireless equipment explains how

to measure the wireless signal

strength

G Reorient the wireless device’s antennas to eliminate

obstructions between them

Part of

message

center

appears

“dead”

Only part of message center will

light

In Composer, check the zone section to make sure the

project is set to use the whole message center

Temperature

Sensor does

NOT work

Not installed A Install sensor in message center

Not enabled Make sure the temperature sensor is enabled in Composer

Light Sensor

does NOT

work

Not installed A Install sensor in message center

Not enabled Make sure the light sensor is set to auto in Composer

Page 13: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

135-0228 Rev. C Page 10 10

GLOSSARY

ACCESS POINT (WIRELESS AP)

A hardware device that allows wireless

communication devices to connect to a

network.

Can also be configured as a

WIRELESS BRIDGE

A hardware device used to connect two or

more network segments.

CASCAN card

Distributes the data inside the Message

Center.

CASCAN card

Page 14: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

135-0228 Rev. C Page 11

11

DISPLAY Panel A group of pixels. Several Display Panels are combined to form the message center.

DSP

Digital Signal Processing.

PIXEL

A group of one or more LEDs.

POE

Power Over Ethernet.

Used to inject power for use by

A device connected to the

Ethernet cable.

POWER SUPPLY

Converts the line voltage to 12 volts or 5 volts.

POWER SWITCH

Disconnects power to a portion of the message center components. Cabinet may contain more than

one.

RIBBON CABLE

Flat 16 conductor cable used to carry the data from the CASCAN card to the display panels and

from display panel to display panel.

WIRELESS BRIDGE A hardware device used to connect two or more network segments. (See Access Point)

X-6 (CONTROLLER)

Stores, processes, and distributes the message center data to the CASCAN card(s).

X-6 CONTROLLER

Page 15: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

DETAIL H

H

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

Important. Read before installation.This is not an engineered drawing. It is intended for representation purposes only. The dimensions called out on this drawing are intended to be used as a guide only, and are not intended to be suitable for all conditions. Information specific to the message center, such as assembly instructions and electrical connections, may be found in the installation manual for that message center. Nevco recommends that you consult a professional engineer or architect familiar with the area before attempting installation. They can verify that the selected mounting beams or posts along with the brackets, screws, and other hardware items provided by you or Nevco are adequate for your local conditions. If procedures are used that are not covered in this drawing, careful analysis of the installation is urged.

Bracket

Full lengthsteel angle

Mounted using steelangle or other structure

mounted to wall.See note top left.

Notes:1. Refer to sheet 3 for cabinet weights and dimensions.

C

11/27/2019

Message CenterIndoor Mounting

Instructions

1 4 JW241-0391

REAR VIEW

3/8" Serrated Flange Bolt Brackets may be boltedor welded to laterals

Page 16: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

Message CenterIndoor Mounting

Instructions

JW 2 4

241-0391

Two Section CabinetInstallation

Cabinets designed to join end to end.

Make sure panels of joining cabinets line up horizontally and make sure both cabinets are level.

If installing message center on laterals, shimming techniquescan be utilized to align and level the two cabinets.

Secure and level first cabinet prior to installing second cabinet.

11/27/2019

C

Page 17: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

C

11/27/2019

Message CenterIndoor Mounting

Instructions

3 4 JW241-0391

POWER/SIGNAL IN

MOUNTING LOCATIONS

Page 18: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

Message CenterIndoor Mounting

Instructions

Dim (C)Dim (D)

Back View of Cabinet(Dimensions to center of bracket)

2 1/4 in

Notes:1. Bracket orientation labels are found on back of message center2. 3/8" bolts to attach brackets to message center are provided by Nevco

12 in25/32 in

Side View of Cabinet

Bracket Mounting Locations

JW 11/27/2019

7/16 in

2 in

Dim (B)

5 in 5 in6 in

Dim (C)

2 1/4 in

Dim (A)

4 4 241-0391

C

Page 19: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

241-0392

1 5

Message CenterOutdoor Mounting

Instructions

JW 11/26/2019

C

Important. Read before installation.This is not an engineered drawing. It is intended for representation purposes only.The dimensions called out on this drawing are intended to be used as a guide only,and are not intended to be suitable for all conditions. Information specific to the message center, such as assembly instructions and electrical connections, may be found in the installation manual for that message center.Nevco recommends that you consult a professionalengineer or architect familiar with the area before attempting installation. They can verify that the selected mounting beams or posts along with the brackets, screws, and other hardware items provided by you or Nevco are adequate for your local soil conditions, wind loads and other conditions. If procedures are used that are not covered in this drawing, careful analysis of the installation is urged.

Coarse aggregate concreteMinimum 24" diameter.Minimum 5' deep.

Important: Bracing (angle, tubing, etc.) must fully support message center. Nevco recommends that you consult a local professional architect or engineer to verify the framework thecabinet will be mounted to.

Check Electrical Prints to determine conduit requirements. (Must meet electric codes.)

Suggested Column Separation

MessageCenterHeight

214"

214"

Upper and Lower Laterals should be placed 21

4" from the top and bottom of the message center as shown

Page 20: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

Message CenterOutdoor Mounting

Instructions

Dim (C)Dim (D)

Back View of Cabinet(Dimensions to center of bracket)

2 1/4 in

Notes:1. Bracket orientation labels are found on back of message center2. 3/8" bolts to attach brackets to message center are provided by Nevco

12 in25/32 in

Side View of Cabinet

Bracket Mounting Locations

JW 11/26/2019

7/16 in

2 in

Dim (B)

5 in 5 in6 in

Dim (C)

2 1/4 in

Dim (A)

2 5 241-0392

C

Page 21: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

DETAIL N

N

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

Wall

WALL MOUNTING

Brackets may be bolted or welded to laterals

3/8" Serrated Flange Bolt

MOUNTING ON COLUMNS

JW

Message CenterOutdoor Mounting

Instructions

11/26/2019 3 5

241-0392

C

Steel angle

Message Center

Bracket(see detailat lower left)

Drill screw

Page 22: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

DETAIL H

C

E

H

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

Double-Sided Mounting

Steel angle and tubing supplied by others

Angle bolted to backof message center

Square tubing welded to columns

MessageCenter

Column

Using Square Tubingfor Laterals

Using Angle for FlushMount

*Power/Signal Panel

3/8" -16 Serrated FlangeBolts supplied by Nevco

Angle welded or bolted to column depending on column location.

Full length angletop and bottom(supplied by others)

*Note:The installation methods shown above may require therelocation of power/signal panels.

Column

3/8 bolt/nut/washer

JW

Message CenterOutdoor Mounting

Instructions

11/26/2019 4 5 241-0392

C

Page 23: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

11/26/2019241-0392

5 5

C

Cabinets designed to join end to end.

Make sure panels of joining cabinets line up horizontally and that both cabinets are level.

See note 1

If installing message center on laterals, shimming techniquescan be utilized to align and level the two cabinets.

Install one cabinet at a time.

Make sure panels of joining cabinets line up horizontally and that both cabinets are level.

Message CenterOutdoor Mounting

Instructions

JW

Two-SectionMessage Centers

Page 24: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

White

GreenWirenuts Provided

Line

Neutral

Ground

Black

JW 4/25/2018275-0729

1 3

Power to Raintight Box

Fiber Optic Signalfrom Control Room

25' Crossover Ethernet Signal to Power/Signal-InAccess Panel.

Power from Branch Circuit

Raintight BoxApplies to installationsgreater then 325 ft.(See Sheet 2)

* Disconnect Switch

* National Electric code requires a disconnect switch within Sight of the sign or lockable within the building. If neither is available, install a disconnect at the sign.

Note: It is not necessary to remove message center display panels to make any of the above connections.

Grounded pigtail locatedinside 2x4 box. Must connect when connecting power.

Power/Signal-In panelcan be relocated to side,bottom or back of messagecenters for wall mounts oradjacent signs.

Feed panel through holeas shown to changelocation of access panels.

Sign Power Connections

Sign Power to 2x4 Box(consult installation instructionsfor amperage requirement)

Important. Read before installation.Power entrances are located on access panels

with 2x4 box. The location of this panel may very

between different message centers. Access panels can be

swapped to allow placement of incoming power/signal on

the side, back or bottom of the message center typically.

This sign is intended to be installed in accordance with

the requirements of Article 600 of the National Electrical

Code and/or other applicable local codes. This includes

proper grounding and bonding of the sign. All personnel

who work with electrical connections must be educated

in the safe procedures for installing and repairing

electrical connections before they are given the

responsibility of performing such tasks. Conduit and

fittings are supplied by installer.

Message CenterWired Installation

A

Page 25: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

275-07292 3 4/25/2018JW

Front View Showing Cabling(for control room and display side)

*Install media converter using two 2" pieces of velcro-type fastener provided by Nevco. Peal adhesive backing and place a strip on back of raintight box and a strip on the media converter. Press firmly to attach.

Adhesive-backed velcro material.

Media Converter

Media Converter Harness

Incoming Power

ETHERNET CABLEDisplay Side: 25' Signal-Inon message center. Control Room Side: 3' to Composer PC

* Media Converter (mount on back of raintight box)

12V AC/DC adaptorto Media Converter

Incoming Fiber Optic Signal

Notes: 1) Connect same color fiber optic cable to "TX"in the control room that is connected to "RX" at the outdoor junction box. Connect same color fiber optic cable to "RX" in the control room that is connected to "TX" at the outdoor junction box. Only attempt termination of fiber optic connections if properly trained and qualified. 2) The rain-tight box and components shown above are required at the display and in the control room. Make connections as shown both sides.

Box, outlet and cover suppliedby Nevco

Conduit fittings suppliedby others. Use only rain-tightfittings.

Message CenterWired Installation

NOTE: This Raintight box only appliesto installations greater then 325 ft.

A

SFP TO LC FIBER ADAPTER

Page 26: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

Power/Signal-In Panel

Power/Signal-In Panel

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

JW 4/25/2018275-0729

3 3

Important. Read before installation.Power entrances are located on access panels

with 2x4 box. The location of this panel may very

between different message centers. Access panels can be

swapped to allow placement of incoming power/signal on

the side, back or bottom of the message center typically.

This sign is intended to be installed in accordance with

the requirements of Article 600 of the National Electrical

Code and/or other applicable local codes. This includes

proper grounding and bonding of the sign. All personnel

who work with electrical connections must be educated

in the safe procedures for installing and repairing

electrical connections before they are given the

responsibility of performing such tasks. Conduit and

fittings are supplied by installer.

Multi-Section Message Center

Single Cabinet Message Center

Power

Temperature Sensor/Photo Cell

Connect ethernet from Signal-Outof first cabinet straight through to Signal-In of second cabinet.

Remove panel and re-mount accordingto label with 2x4 box on outside of cabinet.

Signal-Out

Power

For double sided messagecenters, connect cable hereand run straight through to Signal-In of second message center.

Signal Out(remove plug orknockout to make connection)

Power, Signal-In (ethernet connection from media converter)

Signal Out Signal OutSignal In

Power, Signal In

Message Center A

Message Center BSignal OutSignal In

Multi-Section, Double Sided Message Center

Power

PowerParent LeftChild Right

Child RightChild Left

Note: Cabinet to cabinet signal connections are straight through ethernet.

Cabinet 1 is identified byNevco logo next to Power/Signal-In panel.

Note: Remove knockouts in access panels where necessary to make connections.

Message CenterWired Installation

A

Page 27: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

Client Bridge

(see sheet 6 for mounting)

Signal Strength Meter

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

GroundWirenuts Provided

Green

Neutral

Line

White

Black3 bars required for addequate signal

275-0732

--

Grounded pigtail locatedinside 2x4 box. Must connect when connecting power.

Make connections by removingother access panel near Power/Signal-In panel. Replace all coverswhen connections have beenmade.

* Disconnect Switch

Sign Power to 2x4 Box(consult installation instructionsfor amperage requirement)

Power from Branch Circuit

Power to Raintight Box

Cross Over Ethernet Signal to Power/Signal-InAccess Panel.

Raintight Box(See Sheet 2)

Sign Power Connections

Feed panel through holeas shown to changelocation of access panels.

Power/Signal-In panelcan be relocated to side,bottom or back of messagecenters for wall mount oradjacent signs.

Note: It is not necessary to remove message center display panels to make any connections.

Important. Read before installation.Power entrances are located on access panels

with 2x4 box. The location of this panel may very

between different message centers. Access panels can be swapped to allow placement of

incoming power/signal on the side, back or bottom of the message center typically. This sign

is intended to be installed in accordance with the requirements of Article 600 of the National

Electrical Code and/or other applicable local codes. This includes proper grounding and

bonding of the sign. All personnel who work with electrical connections must be educated in

the safe procedures for installing and repairing electrical connections before they are given the

responsibility of performing such tasks. Conduit and fittings are supplied by installer.

* National Electric code requires a disconnect switch within Sight of the sign or lockable within the building. If neither is available, install a disconnect at the sign.

Client BridgeMount in Clear-Line-Of-Sightto wireless transmitter.

Note: For indoor installations, a raintight box is not required. Make connections same as above.

Ethernet Cable(straight through fromreceiver to POE)

Point client bridge ataccess point in controlroom to obtain required signal strength.

Message CenterWireless Installation

JW 1 5 5/17/2019

Page 28: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

POE

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

275-0732

Notes.1. Use raintight fittings.2. Indoor installations do not require a rain-tight box. Make connections same as above.

Inside Raintight Box(Door Removed for Clarity)

Power Over Ethernet Supply(POE) Mounting POE:1. Cut supplied adhesive-backed fastening material into (2) 2" pieces.2. Peal backing off of one piece and place on back of raintight box in desired location.3. Place second piece on back of POE.4. Press POE firmly onto back of raintight box.

Water-tight bushingsupplied by Nevco(for ethernet cableto wireless receiver)

25' Ethernet (color coded white) straight through from "POE" towireless receiver (supplied by Nevco)

Incoming Power

25' ethernet crossover from"LAN" to message center SIGNAL-IN. Color coded red.

Signal to message center

Power adaptersupplied byNevco.

Water-tight fittings required(supplied by others)

Box, outlet and coversupplied by Nevco.

Ethernet: Wireless Receiver

Ethernet; Message Center Signal

Message CenterWireless Installation

JW2 5

--

5/17/2019

Page 29: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

Power/Signal-In Panel

Power/Signal-In Panel

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

JW275-0732

3 5

Important. Read before installation.Power entrances are located on access panels

with 2x4 box. The location of this panel may very

between different message centers. Access panels can be

swapped to allow placement of incoming power/signal on

the side, back or bottom of the message center typically.

This sign is intended to be installed in accordance with

the requirements of Article 600 of the National Electrical

Code and/or other applicable local codes. This includes

proper grounding and bonding of the sign. All personnel

who work with electrical connections must be educated

in the safe procedures for installing and repairing

electrical connections before they are given the

responsibility of performing such tasks. Conduit and

fittings are supplied by installer.

Multi-Section Message Center

Single Cabinet Message Center

Power

Temperature Sensor/Photo Cell

Connect ethernet from Signal-Outof first cabinet straight through to Signal-In of second cabinet.

Remove panel and re-mount accordingto label with 2x4 box on outside of cabinet.

Signal-Out

Power

For double sided messagecenters, connect cable hereand run straight through to Signal-In of second message center.

Signal Out(remove plug orknockout to make connection)

Power, Signal-In (ethernet connection from media converter)

Signal Out Signal OutSignal In

Power, Signal In

Message Center A

Message Center BSignal OutSignal In

Multi-Section, Double Sided Message Center

Power

PowerParent LeftChild Right

Child RightChild Left

Note: Cabinet to cabinet signal connections are straight through ethernet.

Cabinet 1 is identified byNevco logo next to Power/Signal-In panel.

Note: Remove knockouts in access panels where necessary to make connections.

Message CenterWireless Installation

--

5/17/2019

Page 30: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

3' Crossover Cable(color coded red)

Access Point

Network cable to PCEthernet Interface(crossover)

ImportantWireless devices should be in Clear Line of Sight from each other. Penetration of obstacles by the wireless signal is dependant on the material of the obstacle as well as the overall distance between devices. Both units are suitable for outdoor installation. If building walls become a problem, mount the access point outside the building.

275-0732

Power Over Ethernet (POE) Supply

See ImportantNote Below

LAN

25' ethernet straightthrough. (color codedwhite)

Access Point

Client Bridge

Remove cover andplug into ethernetport closest to the center of the accesspoint.

JW 4 5

Message CenterWireless Installation

--

5/17/2019

Page 31: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

275-0732

Fasten client bridge to mounting bracket using2 supplied zip-ties.

Run zip-ties through twoholes in bracket and throughslot on client bridge.

Client bridge can be mountedto bracket at various angles toachieve optimum line of sightto access point in control room.

Bolt or clamp bracket tocolumn or other structure.(hardware supplied by others)

5/17/2019JW 5 5

Message CenterWireless Installation

--

Page 32: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

GroundWirenuts Provided

Green

Neutral

Line

White

Black

275-0852

--

Grounded pigtail locatedinside 2x4 box. Must connect when connecting power.

Make connections by removingother access panel near Power/Signal-In panel. Replace all coverswhen connections have beenmade.

* Disconnect Switch

Sign Power to 2x4 Box(consult installation instructionsfor amperage requirement)

Power from Branch Circuit

Power to Raintight Box

Ethernet Signal to Power/Signal-InAccess Panel.

Raintight Box(See Sheet 2)

Sign Power Connections

Feed panel through holeas shown to changelocation of access panels.

Power/Signal-In panelcan be relocated to side,bottom or back of messagecenters for wall mount oradjacent signs.

Note: It is not necessary to remove message center display panels to make any connections.

Important. Read before installation.Power entrances are located on access panels

with 2x4 box. The location of this panel may very

between different message centers. Access panels can be swapped to allow placement of

incoming power/signal on the side, back or bottom of the message center typically. This sign

is intended to be installed in accordance with the requirements of Article 600 of the National

Electrical Code and/or other applicable local codes. This includes proper grounding and

bonding of the sign. All personnel who work with electrical connections must be educated in

the safe procedures for installing and repairing electrical connections before they are given the

responsibility of performing such tasks. Conduit and fittings are supplied by installer.

* National Electric code requires a disconnect switch within Sight of the sign or lockable within the building. If neither is available, install a disconnect at the sign.

Note: For indoor installations, a raintightbox is not required. Make connections same as above.

Message CenterWired Installation <325'

MJM 1 3 1/9/2019

Ethernet ToPress Box(<325')

Page 33: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

275-0852

Notes.1. Use raintight fittings.2. Indoor installations do not require a rain-tight box. Make connections same as above.

Water-tight fittings required(Supplied by Others)

Message CenterWired Installation <325'

MJM 2 3

--

1/9/2019

NUC Computer

V3SS2

To PressBox (<325')

DVI to HDMI Cablefrom "NUC" to "V3SS2"

AC/DC AdaptersNUC & V3SS2(Nevco supplied)

Ethernet To MessageCenter From Port Aon V3SS2

4x4 Electrical Box(Nevco supplied)

Power cables hidden for clarity

Incomingpower

Water-tight fittingfor ethernet toPress Box (<325')(Nevco supplied)

Ethernet from NUCto Press Box (<325')

Ethernet to USBadaptor to LAN port on V3SS

Page 34: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

Power/Signal-In Panel

Power/Signal-In Panel

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

MJM275-0852

3 3

Important. Read before installation.Power entrances are located on access panels

with 2x4 box. The location of this panel may very

between different message centers. Access panels can be

swapped to allow placement of incoming power/signal on

the side, back or bottom of the message center typically.

This sign is intended to be installed in accordance with

the requirements of Article 600 of the National Electrical

Code and/or other applicable local codes. This includes

proper grounding and bonding of the sign. All personnel

who work with electrical connections must be educated

in the safe procedures for installing and repairing

electrical connections before they are given the

responsibility of performing such tasks. Conduit and

fittings are supplied by installer.

Multi-Section Message Center

Single Cabinet Message Center

Power

Connect ethernet from Signal-Outof first cabinet straight through to Signal-In of second cabinet.

Remove panel and re-mount accordingto label with 2x4 box on outside of cabinet.

Signal-Out

Power

For double sided messagecenters, connect cable hereand run straight through to Signal-In of second message center.

Signal Out(remove plug orknockout to make connection)

Power, Signal-In (ethernet connection from media converter)

Signal Out Signal OutSignal In

Power, Signal In

Message Center A

Message Center BSignal OutSignal In

Multi-Section, Double Sided Message Center

Power

PowerParent LeftChild Right

Parent RightChild Left

Note: Cabinet to cabinet signal connections are straight through ethernet.

Cabinet 1 is identified byNevco logo next to Power/Signal-In panel.

Note: Remove knockouts in access panels where necessary to make connections.

Message CenterWired Installation <325'

--

1/9/2019

Not Used

Page 35: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

Client Bridge

(see sheet 5 for mounting)

Signal Strength Meter

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

GroundWirenuts Provided

Green

Neutral

Line

White

Black3 bars required for addequate signal

275-0835

--

Grounded pigtail locatedinside 2x4 box. Must connect when connecting power.

Make connections by removingother access panel near Power/Signal-In panel. Replace all coverswhen connections have beenmade.

* Disconnect Switch

Sign Power to 2x4 Box(consult installation instructionsfor amperage requirement)

Power from Branch Circuit

Power to Raintight Box

Ethernet Signal to Power/Signal-InAccess Panel.

Raintight Box(See Sheet 2)

Sign Power Connections

Feed panel through holeas shown to changelocation of access panels.

Power/Signal-In panelcan be relocated to side,bottom or back of messagecenters for wall mount oradjacent signs.

Note: It is not necessary to remove message center display panels to make any connections.

Important. Read before installation.Power entrances are located on access panels

with 2x4 box. The location of this panel may very

between different message centers. Access panels can be swapped to allow placement of

incoming power/signal on the side, back or bottom of the message center typically. This sign

is intended to be installed in accordance with the requirements of Article 600 of the National

Electrical Code and/or other applicable local codes. This includes proper grounding and

bonding of the sign. All personnel who work with electrical connections must be educated in

the safe procedures for installing and repairing electrical connections before they are given the

responsibility of performing such tasks. Conduit and fittings are supplied by installer.

* National Electric code requires a disconnect switch within Sight of the sign or lockable within the building. If neither is available, install a disconnect at the sign.

Client BridgeMount in Clear-Line-Of-Sightto wireless transmitter.

Note: For indoor installations, a raintight box is not required. Make connections same as above.

Ethernet Cable(straight through fromreceiver to POE)

Point client bridge ataccess point in controlroom to obtain required signal strength.

Message CenterWireless Installation

DDS 1 5 1/9/2019

Page 36: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

275-0835

Notes.1. Use raintight fittings.2. Indoor installations do not require a rain-tight box. Make connections same as above.

Power Over Ethernet (POE)Mount with supplied adhesive-backed fastening material

Water-tight fittings required(supplied by others)

Message CenterWireless Installation

DDS 2 5

--

1/9/2019

NUC Computer

V3SS2

Ethernet Crossover Cablefrom "NUC" to "POE".(color coded red)

Connect to "POE" on Power Over Ethernet Supply. Straight through cable.

To Wireless Client Bridge

Power Over Ethernet Supply

DVI to HDMI Cablefrom "NUC" to "V3SS2"

AC/DC AdaptersNUC & V3SS2(Nevco supplied)

To Message CenterFrom Port A on V3SS2

4x4 Electrical Box(Nevco supplied)

Power cables hidden for clarity

Incomingpower

"POE"

NUC Computer

"LAN"

Crossover (red)25 ftStraight through

POE

Client Bridge

Water-tight fittingfor wireless Client Bridge (Nevco supplied)

Ethernet to USBadapter to LANport on V3SS

Page 37: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

Power/Signal-In Panel

Power/Signal-In Panel

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

DDS275-0835

3 5

Important. Read before installation.Power entrances are located on access panels

with 2x4 box. The location of this panel may very

between different message centers. Access panels can be

swapped to allow placement of incoming power/signal on

the side, back or bottom of the message center typically.

This sign is intended to be installed in accordance with

the requirements of Article 600 of the National Electrical

Code and/or other applicable local codes. This includes

proper grounding and bonding of the sign. All personnel

who work with electrical connections must be educated

in the safe procedures for installing and repairing

electrical connections before they are given the

responsibility of performing such tasks. Conduit and

fittings are supplied by installer.

Multi-Section Message Center

Single Cabinet Message Center

Power

Connect ethernet from Signal-Outof first cabinet straight through to Signal-In of second cabinet.

Remove panel and re-mount accordingto label with 2x4 box on outside of cabinet.

Signal-Out

Power

For double sided messagecenters, connect cable hereand run straight through to Signal-In of second message center.

Signal Out(remove plug orknockout to make connection)

Power, Signal-In (ethernet connection from media converter)

Signal Out Signal OutSignal In

Power, Signal In

Message Center A

Message Center BSignal OutSignal In

Multi-Section, Double Sided Message Center

Power

PowerMaster LeftSlave Right

Slave RightSlave Left

Note: Cabinet to cabinet signal connections are straight through ethernet.

Cabinet 1 is identified byNevco logo next to Power/Signal-In panel.

Note: Remove knockouts in access panels where necessary to make connections.

Message CenterWireless Installation

--

1/9/2019

Not Used

Page 38: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

3' Crossover Cable(color coded red)

Access Point

Network cable to PCEthernet Interface(crossover)

ImportantWireless devices should be in Clear Line of Sight from each other. Penetration of obstacles by the wireless signal is dependant on the material of the obstacle as well as the overall distance between devices. Both units are suitable for outdoor installation. If building walls become a problem, mount the access point outside the building.

275-0835

Power Over Ethernet (POE) Supply

See ImportantNote Below

LAN

25' ethernet straightthrough. (color codedwhite)

Access Point

Client Bridge

Remove cover andplug into ethernetport closest to the center of the accesspoint.

DDS 4 5

Message CenterWireless Installation

--

1/9/2019

Page 39: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

275-0835

Fasten client bridge to mounting bracket using2 supplied zip-ties.

Run zip-ties through twoholes in bracket and throughslot on client bridge.

Client bridge can be mountedto bracket at various angles toachieve optimum line of sightto access point in control room.

Bolt or clamp bracket tocolumn or other structure.(hardware supplied by others)

1/9/2019DDS 5 5

Message CenterWireless Installation

--

Page 40: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

DJW 2/20/2014 1 1

DWG-0693

Temperature SensorPhoto Cell

Locating the Sensors1) Place in a discrete location.2) Do not completely enclose the sensor box.3) Placing the sensors in direct sunlight can elevate the temperature readings.4) Automatically adjusts brightness from 7000-960 NITS.5) The software that runs the display will allow the operator to set brightness as well as the display frame speed etc. to meet local ordinances.

Connect cable from sensor toTemp. Sensor Photo Cell cablelocated behind Power/Signal-Inaccess panel. Install throughsupplied bushing.

* Power/Signal-In Access Panel

Remove other access panelto make connections and replace when finished. Wiresfor connections locatedinside cabinet.

* Connections can be made using supplied bushings and nuts or 1/2 conduit.

Note: It is not necessary to remove display panels to make any connections.

Message Center

Wired Installation

Power

Remove knockout onpanel here to makeconnection.

Signal-In- cross over from media converter- remove knockout label 'Signal In' on panel to make connection

Page 41: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

DETAIL M

SCALE .25

1

1

2

2

3

3

4

4

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Rev

Nevco, Inc. Greenville, Illinois 62246

MJM 10/22/2019 1 1 DWG-0893

Locating the Sensor1) Place in a discrete location.2) Do not completely enclose the sensor.3) Placing the sensor in direct sunlight can elevate the temperature readings.4) Automatically adjusts brightness from 7000-960 NITS.5) The software that runs the display will allow the operator to set brightness as well as the display frame speed etc. to meet local ordinances.

Connect cable from sensor toV3SS Sensor Port inside raintight box. Drill hole in rain tightbox and run cable through.Install raintight fitting.See 275-0852 for wiredSee 275-0835 for wireless

* Power/Signal-In Access Panel

Remove other access panelto make connections and replace when finished. Wiresfor connections locatedinside cabinet.

* Connections can be made using supplied bushings and nuts or 1/2 conduit.

10mm/16mmPhotocell

Installation

Power

Signal-In- cross over from media converter- remove knockout label 'Signal In' on panel to make connection

Sensor can be screweddirectly to the side of thecabinet using the attachedangle bracket.

Page 42: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

1

1

2

2

3

3

4

4

5

5

6

6

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Nevco, Inc. Greenville, Illinois 62246

Rev

Last ECO

10mm Message Center Installation

MJM 1 5

DWG-0808

9/19/2016

--

96 in 120 in

96 in 120 in

48 in

48 in

36 3

/32

in

36 3

/32

in

10mm Message Centers

3' x 8': 94 lbs. 3' x 10': 112 lbs.

4' x 8': 125 lbs. 4' x 10': 150 lbs.

Page 43: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

DETAIL A

A

1

1

2

2

3

3

4

4

5

5

6

6

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Nevco, Inc. Greenville, Illinois 62246

Rev

Last ECO

10mm Message Center Installation

MJM 9/19/2016 2 5

DWG-0808

--Installation Method One: Stand Alone Message Center

A

Step 1:Attach brackets to wall using the following dimensions. Anchor types should be evaluated and selected by anengineer or architect familiar with the building'sconstruction. (Attachment by Others)

Bolt cabinet to bracket using(4) 3/8" serrated flange boltsper bracket (Supplied by Nevco)Note orientation of brackets

B Message Center

C C

Step 2:Attach cabinet to brackets

12 in

1 in 1 in6 in

1 in 25/32 in

Page 44: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

1

1

2

2

3

3

4

4

5

5

6

6

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Nevco, Inc. Greenville, Illinois 62246

Rev

Last ECO

10mm Message Center Installation

MJM 9/19/2016 3 5

DWG-0808

--Installation Method Two:Message Center On Angle

Steel Supplied by OthersPart Description Size Length Quantity

A 8' Message Center Angle Steel Angle 2"x2"x1/8" 7' 2B 10' Message Center Angle Steel Angle 2"x2"x1/8" 9' 2

Step 1: Mount 2" x 2" x 1/8" angle to the wall. (Steel angles and connections by others)

A/B

2 in 2 in

Wall

C D

Step 2: Attach 12" angle bracketsto back of message center using (4)3/8" serrated flange bolts (suppliedby Nevco). Note orientation of brackets

Step 3: Attach 12" angle brackets totop message center brackets using3/8" bolts, washers, and nuts(Supplied by Nevco).

Provide Attachment to wall at minimum ofthree locations. Anchor types shouldbe evaluated and selected by an engineeror architect familiar with the building'sconstruction.

Page 45: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

1

1

2

2

3

3

4

4

5

5

6

6

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Nevco, Inc. Greenville, Illinois 62246

Rev

Last ECO

9/19/2016MJM

10mm Message Center Installation

DWG-0808

4 5

--Installation Method Two:Message Center On Angle

Step 4 Attach message centerto 2" x 2" Angle on wall using5/16" drill screws or 3/8" bolts(Supplied by Others)Minimum of 2 per bracket

8 in

Right Side View

Page 46: Nevco 10mm/16mm/20mm/32mm Message Centers (x6xx ... Centers... · connected to a cable inside the message center behind the access panel. At the lower right corner of the message

1

1

2

2

3

3

4

4

5

5

6

6

A A

B B

C C

D D

Drawn Date

Drawing No.

Sheet of

Nevco, Inc. Greenville, Illinois 62246

Rev

Last ECO

10mm Message Center Installation

MJM 9/19/2016 5 5

DWG-0808

--

Electrical ConnectionLocations

Rear View

Actual Full-Load Power Consumption (120-240VAC, 50/60 Hz) AmpsMessage Center @120VAC @208VAC @240VAC

3' x 8' 5.8A 3.4A 2.9A3' x 10' 7.0A 4.0A 3.5A4' x 8' 7.8A 4.5A 3.9A4' x 10' 9.3A 5.4A 4.7A

Shuttle Computer 0.8A 0.5A 0.4AImportant. Read before Installation.This display is intended to be installed in accordance withthe requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. All personnel who work with electrical connections must be educated inthe safe procedures for installing and repairing electrical connections before they are given the responsibility of performing such tasks. * National Electrical Code requires a disconnect switchwithin sight of sign or lockable within the building. If asubpanel is fed via a breaker from a main panel inside the building, ensure a lockable panel is installed.

Signal LocationPower Location

Connect power on message centerusing 15' power cable. Installer to providea receptacle for power connection

Connect 6' HDMI cable frommessage center to shuttlecomputer (If >6' required, extend up to 35' with HDMIstriaght patch cables)

Power for shuttleusing standard plug

Reference the following drawingsfor wiring options: Wireless: 275-0732Wired: 275-0729

Ethernet PortsHDMI Port

PowerShuttle Computer

1 3/4 in

7 1/2 in

6 1/2 in