Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 2 of 40

Declaration

Neutron represents to the client that testing is done in accordance with standard procedures as applicableand that test instruments used has been calibrated with the standards traceable to National MeasurementLaboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A.

Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’sresponsibility to ensure that additional production units of this model are manufactured with the identicalelectrical and mechanical components. Neutron shall have no liability for any declarations, inferences orgeneralizations drawn by the client or others from Neutron issued reports.

Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government.

This report is the confidential property of the client. As a mutual protection to the clients, the public andNeutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval.

Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025requirements, and accredited by the conformity assessment authorities listed in this test report.

Limitation

For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in thistest report is (are) included in the conformity assessment authorities acceptance respective.

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 3 of 40

Table of Contents

Page

1 . CERTIFICATION 4

2 . SUMMARY OF TEST RESULTS 5

2.1 TEST FACILITY 6

2.2 MEASUREMENT UNCERTAINTY 6

3 . GENERAL INFORMATION 7

3.1 GENERAL DESCRIPTION OF EUT 7

3.2 DESCRIPTION OF TEST MODES 10

3.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11

3.4 DESCRIPTION OF SUPPORT UNITS 12

4 . EMC EMISSION TEST 13

4.1 CONDUCTED EMISSION MEASUREMENT 13 4.1.1 POWER LINE CONDUCTED EMISSION 13 4.1.2 MEASUREMENT INSTRUMENTS LIST 13 4.1.3 TEST PROCEDURE 14 4.1.4 DEVIATION FROM TEST STANDARD 14 4.1.5 TEST SETUP 14 4.1.6 BLOCK DIAGRAM OF TEST SETUP 15 4.1.7 EUT OPERATING CONDITIONS 15 4.1.8 TEST RESULTS 16

4.2 RADIATED EMISSION MEASUREMENT 26 4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT 26 4.2.2 MEASUREMENT INSTRUMENTS LIST 27 4.2.3 TEST PROCEDURE 27 4.2.4 DEVIATION FROM TEST STANDARD 27 4.2.5 TEST SETUP 28 4.2.6 BLOCK DIAGRAM OF TEST SETUP 28 4.2.7 EUT OPERATING CONDITIONS 28 4.2.8 TEST RESULTS 29

5 . EUT TEST PHOTO 39

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 4 of 40

1. CERTIFICATION E q u i p men t : Switching Power Supply Brand Name :

Model Name : EFS012XXXXYYYYOO (XXXX-Where XXXX represents output voltage, from 0050 to 0240; YYYY-Where YYYY represents output current, from 0040 to 0240; OO-Where OO represents country or area.)

A p p l i c a n t : Eastern Frontier Co., Ltd F a c t o r y : Eastern Frontier (Shenzhen) Co., Ltd

A d d r e s s : Factory Bldg., #A, Hua Fa Road Area, Da Lang Street, Bao An District, Shenzhen, China

Date of Test : May. 08, 2009 ~ May. 12, 2009 S t a n d a r d s :

FCC Part 15, Subpart B, Class B CISPR 22: 1997+A1: 2000, Class B ICES-003: 2004, Class B ANSI C63.4-2003

The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FCCE-1-0904C096) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality assessment standard and technical standard(s).

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 5 of 40

2. SUMMARY OF TEST RESULTS

Test procedures according to the technical standards:

EMC Emission

Standard Test Item Limit Judgment Remark

Conducted Emission Class B PASS FCC Part15, Subpart B CISPR 22:1997+A1: 2000

ICES-003: 2004 Radiated Emission Class B PASS

NOTE: (1) ” N/A” denotes test is not applicable in this Test Report.

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 6 of 40

2.1 TEST FACILITY The test facilities used to collect the test data in this report is C01/OS02 at the location of

No.132-1, Lane 329, Sec. 2, Palain Road, Shijr City, Taipei, Taiwan.

2.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a

standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95%。 A. Conducted Measurement :

Test Site Method Measurement Frequency Range U,(dB) NOTE C01 ANSI 150 KHz ~ 30MHz 1.94

B. Radiated Measurement :

Test Site Method Measurement Frequency Range

Ant. H / V U,(dB) NOTE

30MHz ~ 200MHz V 3.82 30MHz ~ 200MHz H 3.60

200MHz ~ 1,000MHz V 3.86 OS-01 ANSI

200MHz ~ 1,000MHz H 3.94 30MHz ~ 200MHz V 2.48 30MHz ~ 200MHz H 2.16

200MHz ~ 1,000MHz V 2.50 OS-02 ANSI

200MHz ~ 1,000MHz H 2.66

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 7 of 40

3. GENERAL INFORMATION

3.1 GENERAL DESCRIPTION OF EUT

Equipment Switching Power Supply

Brand Name

Model Name

EFS012XXXXYYYYOO (XXXX-Where XXXX represents output voltage, from 0050 to 0240; YYYY-Where YYYY represents output current, from 0040 to 0240; OO-Where OO represents country or area.)

OEM Brand/Model Name N/A

Model Difference N/A

Product Description

The EUT is a Switching Power Supply. Based on the application, features, or specification exhibited in User's Manual, the EUT is considered as an ITE/Computing Device. More details of EUT technical specification, please refer to the User's Manual.

Power Source AC Mains.

Power Rating AC I/P: 100-240V~ 50/60Hz 0.4A 12W More details please see note 2 in next page.

Connecting I/O Port(s) Please refer to the User's Manual Products Covered N/A EUT Modification(s) N/A

Note: 1. For a more detailed features description, please refer to the manufacturer’s specifications

or the User's Manual.

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 8 of 40

2.

Model Name Output Voltage (Vdc)

Output Current

(mA) Transformer Test model

EFS01200500240UL 5 2400 EFT-00172 *

EFS01200500230UL 5 2300 EFT-00172

EFS01200500220UL 5 2200 EFT-00172

EFS01200500210UL 5 2100 EFT-00172

EFS01200500200UL 5 2000 EFT-00172

EFS01200600200UL 6 2000 EFT-00172

EFS01200600190UL 6 1900 EFT-00172

EFS01200600180UL 6 1800 EFT-00172

EFS01200600170UL 6 1700 EFT-00172

EFS01200700170UL 7 1700 EFT-00186

EFS01200800150UL 8 1500 EFT-00186

EFS01200800140UL 8 1400 EFT-00186

EFS01200800130UL 8 1300 EFT-00186

EFS01200890134UL 8.9 1340 EFT-00186

EFS01200890130UL 8.9 1300 EFT-00186

EFS01200900133UL 9 1330 EFT-00187 *

EFS01200900130UL 9 1300 EFT-00187

EFS01200900120UL 9 1200 EFT-00187

EFS01200900110UL 9 1100 EFT-00187

EFS01200900100UL 9 1000 EFT-00187

EFS01201000120UL 10 1200 EFT-00187

EFS01201000130UL 10 1100 EFT-00187

EFS01201000100UL 10 1000 EFT-00187

EFS01201200100UL 12 1000 EFT-00187 *

EFS01201200090UL 12 900 EFT-00187

EFS01201200080UL 12 800 EFT-00187

EFS01201400085UL 14 850 EFT-00188

EFS01201400080UL 14 800 EFT-00188

EFS01201400070UL 14 700 EFT-00188

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 9 of 40

EFS01201500080UL 15 800 EFT-00188

EFS01201500070UL 15 700 EFT-00188

EFS01201600075UL 16 750 EFT-00188

EFS01201600070UL 16 700 EFT-00188

EFS01201800065UL 18 650 EFT-00189

EFS01201800060UL 18 600 EFT-00189

EFS01201900060UL 19 600 EFT-00189

EFS01201900050UL 19 500 EFT-00189

EFS01202000060UL 20 600 EFT-00189 *

EFS01202000050UL 20 500 EFT-00189

EFS01202090057UL 20.9 570 EFT-00189

EFS01202100057UL 21 570 EFT-00190

EFS01202100050UL 21 500 EFT-00190

EFS01202100040UL 21 400 EFT-00190

EFS01202200050UL 22 500 EFT-00190

EFS01202200040UL 22 400 EFT-00190

EFS01202300050UL 23 500 EFT-00190

EFS01202400050UL 24 500 EFT-00190 *

EFS01202400040UL 24 400 EFT-00190

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 10 of 40

3.2 DESCRIPTION OF TEST MODES

To investigate the maximum EMI emission characteristics generated from EUT, the test system was pre-scanning tested base on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively.

Pretest Mode Description

Mode 1 Full Load

For Conducted / Radiated Test

Final Test Mode Description

Mode 1 Full Load

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 11 of 40

3.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED

E-2 Dummy Load

C-1

C-1 DC Power Cable

E-1 EUT

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 12 of 40

3.3 DESCRIPTION OF SUPPORT UNITS

The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests.

Item Equipment Mfr/Brand Model/Type No. FCC ID Series No. Note

E-1 Switching

Power Supply

EFS012XXXXYYYYOO DOC N/A EUT

E-2 Dummy Load N/A N/A N/A N/A

Item Shielded Type Ferrite Core Length Note C-1 NO NO 1.8M

Note:

(1) The support equipment was authorized by Declaration of Conformity. (2) For detachable type I/O cable should be specified the length in cm in『Length』column.

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 13 of 40

4. EMC EMISSION TEST

4.1 CONDUCTED EMISSION MEASUREMENT 4.1.1 POWER LINE CONDUCTED EMISSION (FREQUENCY RANGE 150KHZ-30MHZ)

Class A (dBuV) Class B (dBuV) FREQUENCY (MHz)

Quasi-peak Average Quasi-peak Average 0.15 -0.5 79.00 66.00 66 – 56 * 56 – 46 * 0.50 -5.0 73.00 60.00 56.00 46.00 5.0 -30.0 73.00 60.00 60.00 50.00

Note: (1) The tighter limit applies at the band edges. (2) The limit of “ * “ marked band means the limitation decreases linearly with the

logarithm of the frequency in the range. 4.1.2 MEASUREMENT INSTRUMENTS LIST

Item Kind of Equipment Manufacturer Type No. Serial No. Calibrated until

1 Test Cable N/A SR03_C_01&02 N/A Oct. 19, 2009

2 LISN EMCO 3816/2 00042991 Jan. 21, 2010

3 Pulse Limiter Electro-Metrics EM-7600 112644 Dec. 28, 2009

4 50Ω Terminator N/A N/A N/A May. 12, 2010

5 EMI Test Receiver R&S ESCI 100082 Mar. 17, 2010

Remark: ” N/A” denotes No Model Name, Serial No. or No Calibration specified.

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 14 of 40

4.1.3 TEST PROCEDURE a. The EUT was placed 0.4 meters from the horizontal ground plane with EUT being connected

to the power mains through a line impedance stabilization network (LISN). All other support equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling impedance for the measuring instrument.

b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and forth in the center forming a bundle 30 to 40 cm long.

c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the cable may be terminated, if required, using the correct terminating impedance. The overall length shall not exceed 1 m.

d. LISN at least 80 cm from nearest part of EUT chassis. e. For the actual test configuration, please refer to the related Item –EUT Test Photos.

4.1.4 DEVIATION FROM TEST STANDARD No deviation 4.1.5 TEST SETUP

LISN

EUT Test Receiver40 cm

80 cm

Horizontal Reference Ground Plane

Vertical Reference Ground Plane

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 15 of 40

4.1.6 BLOCK DIAGRAM OF TEST SETUP

Dummy LoadL.I.S.N.#1

Test Receiver

AC Mains DC Power CableEUT

4.1.7 EUT OPERATING CONDITIONS The EUT exercise program used during radiated and/or conducted emission measurement was designed to exercise the various system components in a manner similar to a typical use.

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 16 of 40

4.1.8 TEST RESULTS E.U.T : Switching Power Supply Model Name : EFS012XXXXYYYYOO Temperature : 26°C Relative Humidity : 60 % Pressure : 1015 hPa Test Voltage : AC 120V/60Hz Test Mode : Full Load (5V/2.4A)

Freq. Terminal Margin(MHz) L/N QP-Mode AV-Mode QP-Mode AV-Mode (dB)

0.15 Line 59.44 38.35 65.77 55.77 -6.33 (QP)0.20 Line 59.24 43.44 63.76 53.76 -4.52 (QP)0.26 Line 53.95 39.34 61.40 51.40 -7.45 (QP)0.33 Line 48.20 33.73 59.58 49.58 -11.38 (QP)0.39 Line 41.53 * 58.02 48.02 -16.49 (QP)0.45 Line 39.71 * 56.79 46.79 -17.08 (QP)

Measured(dBuV) Limits(dBuV) Note

Remark

(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode withDetector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。Reading in which marked as AV means measurements by using are Average Mode with instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。

(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If the QP Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of Interference Voltage Measured。

(3) Measuring frequency range from 150KHz to 30MHz。

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 17 of 40

E.U.T : Switching Power Supply Model Name : EFS012XXXXYYYYOO Temperature : 26°C Relative Humidity : 60 % Pressure : 1015 hPa Test Voltage : AC 120V/60Hz Test Mode : Full Load (5V/2.4A)

Freq. Terminal Margin(MHz) L/N QP-Mode AV-Mode QP-Mode AV-Mode (dB)

0.15 Neutral 59.50 37.68 65.99 55.99 -6.49 (QP)0.19 Neutral 57.92 33.27 63.86 53.86 -5.94 (QP)0.26 Neutral 53.21 38.47 61.42 51.42 -8.21 (QP)0.33 Neutral 46.89 * 59.58 49.58 -12.69 (QP)0.40 Neutral 39.33 * 57.92 47.92 -18.59 (QP)

14.85 Neutral 45.95 * 60.00 50.00 -14.05 (QP)

Measured(dBuV) Limits(dBuV) Note

Remark

(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode withDetector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。Reading in which marked as AV means measurements by using are Average Mode with instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。

(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If the QP Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of Interference Voltage Measured。

(3) Measuring frequency range from 150KHz to 30MHz。

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 18 of 40

E.U.T : Switching Power Supply Model Name : EFS012XXXXYYYYOO Temperature : 26°C Relative Humidity : 60 % Pressure : 1015 hPa Test Voltage : AC 120V/60Hz Test Mode : Full Load (9V/1.33A)

Freq. Terminal Margin(MHz) L/N QP-Mode AV-Mode QP-Mode AV-Mode (dB)

0.15 Line 62.12 38.95 65.97 55.97 -3.85 (QP)0.20 Line 59.62 42.94 63.57 53.57 -3.95 (QP)0.26 Line 53.54 37.74 61.30 51.30 -7.76 (QP)0.33 Line 48.34 32.93 59.36 49.36 -11.02 (QP)0.40 Line 43.40 * 57.87 47.87 -14.47 (QP)0.47 Line 40.21 * 56.56 46.56 -16.35 (QP)

Measured(dBuV) Limits(dBuV) Note

Remark

(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode withDetector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。Reading in which marked as AV means measurements by using are Average Mode with instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。

(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If the QP Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of Interference Voltage Measured。

(3) Measuring frequency range from 150KHz to 30MHz。

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 19 of 40

E.U.T : Switching Power Supply Model Name : EFS012XXXXYYYYOO Temperature : 26°C Relative Humidity : 60 % Pressure : 1015 hPa Test Voltage : AC 120V/60Hz Test Mode : Full Load (9V/1.33A)

Freq. Terminal Margin(MHz) L/N QP-Mode AV-Mode QP-Mode AV-Mode (dB)

0.15 Neutral 61.11 38.38 66.00 56.00 -4.89 (QP)0.20 Neutral 58.01 42.77 63.63 53.63 -5.62 (QP)0.27 Neutral 52.11 37.07 61.27 51.27 -9.16 (QP)0.34 Neutral 48.07 34.46 59.33 49.33 -11.26 (QP)0.40 Neutral 43.73 * 57.90 47.90 -14.17 (QP)

12.66 Neutral 47.61 * 60.00 50.00 -12.39 (QP)

Measured(dBuV) Limits(dBuV) Note

Remark

(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode withDetector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。Reading in which marked as AV means measurements by using are Average Mode with instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。

(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If the QP Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of Interference Voltage Measured。

(3) Measuring frequency range from 150KHz to 30MHz。

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 20 of 40

E.U.T : Switching Power Supply Model Name : EFS012XXXXYYYYOO Temperature : 26°C Relative Humidity : 60 % Pressure : 1015 hPa Test Voltage : AC 120V/60Hz Test Mode : Full Load (12V/1A)

Freq. Terminal Margin(MHz) L/N QP-Mode AV-Mode QP-Mode AV-Mode (dB)

0.15 Line 56.11 35.35 66.00 56.00 -9.89 (QP)0.19 Line 57.14 40.94 64.11 54.11 -6.97 (QP)0.25 Line 50.88 36.34 61.66 51.66 -10.78 (QP)0.31 Line 45.93 * 59.85 49.85 -13.92 (QP)0.37 Line 41.30 * 58.42 48.42 -17.12 (QP)

13.34 Line 44.13 * 60.00 50.00 -15.87 (QP)

Measured(dBuV) Limits(dBuV) Note

Remark

(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode withDetector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。Reading in which marked as AV means measurements by using are Average Mode with instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。

(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If the QP Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of Interference Voltage Measured。

(3) Measuring frequency range from 150KHz to 30MHz。

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 21 of 40

E.U.T : Switching Power Supply Model Name : EFS012XXXXYYYYOO Temperature : 26°C Relative Humidity : 60 % Pressure : 1015 hPa Test Voltage : AC 120V/60Hz Test Mode : Full Load (12V/1A)

Freq. Terminal Margin(MHz) L/N QP-Mode AV-Mode QP-Mode AV-Mode (dB)

0.15 Neutral 56.29 35.58 65.88 55.88 -9.59 (QP)0.19 Neutral 56.18 39.97 64.14 54.14 -7.96 (QP)0.25 Neutral 50.66 36.16 61.77 51.77 -11.11 (QP)0.31 Neutral 44.86 * 59.89 49.89 -15.03 (QP)0.37 Neutral 40.29 * 58.40 48.40 -18.11 (QP)

12.71 Neutral 46.27 * 60.00 50.00 -13.73 (QP)

Measured(dBuV) Limits(dBuV) Note

Remark

(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode withDetector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。Reading in which marked as AV means measurements by using are Average Mode with instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。

(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If the QP Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of Interference Voltage Measured。

(3) Measuring frequency range from 150KHz to 30MHz。

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 22 of 40

E.U.T : Switching Power Supply Model Name : EFS012XXXXYYYYOO Temperature : 26°C Relative Humidity : 60 % Pressure : 1015 hPa Test Voltage : AC 120V/60Hz Test Mode : Full Load (20V/0.6A)

Freq. Terminal Margin(MHz) L/N QP-Mode AV-Mode QP-Mode AV-Mode (dB)

0.15 Line 60.61 37.35 66.00 56.00 -5.39 (QP)0.21 Line 60.55 39.54 63.41 53.41 -2.86 (QP)0.27 Line 53.99 39.24 61.27 51.27 -7.28 (QP)0.33 Line 47.31 28.83 59.45 49.45 -12.14 (QP)0.40 Line 43.68 * 57.96 47.96 -14.28 (QP)0.46 Line 40.70 * 56.69 46.69 -15.99 (QP)

Measured(dBuV) Limits(dBuV) Note

Remark

(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode withDetector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。Reading in which marked as AV means measurements by using are Average Mode with instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。

(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If the QP Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of Interference Voltage Measured。

(3) Measuring frequency range from 150KHz to 30MHz。

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 23 of 40

E.U.T : Switching Power Supply Model Name : EFS012XXXXYYYYOO Temperature : 26°C Relative Humidity : 60 % Pressure : 1015 hPa Test Voltage : AC 120V/60Hz Test Mode : Full Load (20V/0.6A)

Freq. Terminal Margin(MHz) L/N QP-Mode AV-Mode QP-Mode AV-Mode (dB)

0.16 Neutral 56.60 31.38 65.73 55.73 -9.13 (QP)0.17 Neutral 56.23 37.58 65.21 55.21 -8.98 (QP)0.20 Neutral 56.57 37.77 63.82 53.82 -7.25 (QP)0.27 Neutral 50.71 33.47 61.27 51.27 -10.56 (QP)0.33 Neutral 44.38 * 59.45 49.45 -15.07 (QP)

13.94 Neutral 48.59 42.20 60.00 50.00 -7.80 (AV)

Measured(dBuV) Limits(dBuV) Note

Remark

(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode withDetector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。Reading in which marked as AV means measurements by using are Average Mode with instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。

(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If the QP Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of Interference Voltage Measured。

(3) Measuring frequency range from 150KHz to 30MHz。

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 24 of 40

E.U.T : Switching Power Supply Model Name : EFS012XXXXYYYYOO Temperature : 26°C Relative Humidity : 60 % Pressure : 1015 hPa Test Voltage : AC 120V/60Hz Test Mode : Full Load (24V/0.5A)

Freq. Terminal Margin(MHz) L/N QP-Mode AV-Mode QP-Mode AV-Mode (dB)

0.15 Line 9.31 37.05 66.00 56.00 -18.95 (AV)0.17 Line 55.98 40.85 65.04 55.04 -9.06 (QP)0.20 Line 59.70 31.84 63.81 53.81 -4.11 (QP)0.26 Line 54.28 34.94 61.44 51.44 -7.16 (QP)0.33 Line 48.10 33.23 59.45 49.45 -11.35 (QP)0.38 Line 44.71 * 58.18 48.18 -13.47 (QP)

Measured(dBuV) Limits(dBuV) Note

Remark

(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode withDetector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。Reading in which marked as AV means measurements by using are Average Mode with instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。

(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If the QP Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of Interference Voltage Measured。

(3) Measuring frequency range from 150KHz to 30MHz。

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 25 of 40

E.U.T : Switching Power Supply Model Name : EFS012XXXXYYYYOO Temperature : 26°C Relative Humidity : 60 % Pressure : 1015 hPa Test Voltage : AC 120V/60Hz Test Mode : Full Load (24V/0.5A)

Freq. Terminal Margin(MHz) L/N QP-Mode AV-Mode QP-Mode AV-Mode (dB)

0.15 Neutral 59.17 36.98 66.00 56.00 -6.83 (QP)0.19 Neutral 58.86 40.87 64.08 54.08 -5.22 (QP)0.27 Neutral 53.00 39.37 61.14 51.14 -8.14 (QP)0.32 Neutral 46.98 * 59.73 49.73 -12.75 (QP)0.39 Neutral 42.92 * 58.15 48.15 -15.23 (QP)0.45 Neutral 38.53 * 56.86 46.86 -18.33 (QP)

Measured(dBuV) Limits(dBuV) Note

Remark

(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode withDetector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。Reading in which marked as AV means measurements by using are Average Mode with instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。

(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If the QP Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of Interference Voltage Measured。

(3) Measuring frequency range from 150KHz to 30MHz。

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 26 of 40

4.2 RADIATED EMISSION MEASUREMENT

4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT

Class A (at 10m) Class B (at 10m) FREQUENCY (MHz)

dBuV/m dBuV/m 30 – 230 40 30

230 – 1000 47 37 Notes: (1) The limit for radiated test was performed according to as following:

CISPR 22/ FCC PART 15B /ICES-003. (2) The tighter limit applies at the band edges. (3) Emission level (dBuV/m)=20log Emission level (uV/m).

LIMITS OF RADIATED EMISSION MEASUREMENT (Above 1000MHz)

Class A (dBuV/m) (at 3m) Class B (dBuV/m) (at 3m) FREQUENCY (MHz)

PEAK AVERAGE PEAK AVERAGE

Above 1000 80 60 74 54 Notes: (1) The limit for radiated test was performed according to FCC PART 15B. (2) The tighter limit applies at the band edges. (3) Emission level (dBuV/m)=20log Emission level (uV/m).

FREQUENCY RANGE OF RADIATED MEASUREMENT (For unintentional radiators)

Highest frequency generated or Upper frequency of

measurement used in the device or on which the device operates

or tunes (MHz)

Range (MHz)

Below 1.705 30 1.705 – 108 1000 108 – 500 2000

500 – 1000 5000

Above 1000 5th harmonic of the highest frequency or 40 GHz, whichever is lower

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 27 of 40

4.2.2 MEASUREMENT INSTRUMENTS LIST

Item Kind of Equipment Manufacturer Type No. Serial No. Calibrated until 1 Log-Bicon Antenna Schwarzbeck VULB 9160 3176 Jul. 24, 2009

2 Test Cable N/A 10M_OS01 N/A Oct. 20, 2009

3 Test Cable N/A OS01-1/-2 N/A Oct. 08, 2009

4 Pre-Amplifier Anritsu MH648A M09961 Dec. 29, 2009

5 Positioning Controller (OS01) MF MF7802 N/A N/A

6 Turn Table Chance Most CMTB-1.5 N/A N/A

7 Spectrum Analyzer (1G) R&S FSP-40 100129 Sep. 09, 2009

8 EMI Measuring Receiver SHCAFFNER SCR 3501 408 Nov. 24.2009

Remark: ” N/A” denotes No Model Name / Serial No. and No Calibration specified.

4.2.3 TEST PROCEDURE a. The measuring distance of at 10 m shall be used for measurements at frequency up to 1GHz.

For frequencies above 1GHz, any suitable measuring distance may be used. b. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3m or 10

meter open area test site. The table was rotated 360 degrees to determine the position of the highest radiation.

c. The height of the equipment or of the substitution antenna shall be 0.8 m; the height of the test antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the antenna are set to make the measurement.

d. The initial step in collecting radiated emission data is a spectrum analyzer peak detector mode pre-scanning the measurement frequency range. Significant peaks are then marked and then Quasi Peak detector mode re-measured.

e. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement performed.

f. For the actual test configuration, please refer to the related Item –EUT Test Photos.

4.2.4 DEVIATION FROM TEST STANDARD No deviation

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 28 of 40

4.2.5 TEST SETUP

Amp.

EUT

80 cm

Ground Plane

1-4 m

3 or 10 m

Test Receiver

4.2.6 BLOCK DIAGRAM OF TEST SETUP

Dummy LoadAC Mains

DC Power CableEUT

4.2.7 EUT OPERATING CONDITIONS The EUT tested system was configured as the statements of 4.1.7 Unless otherwise a special operating condition is specified in the follows during the testing.

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 29 of 40

4.2.8 TEST RESULTS E.U.T : Switching Power Supply Model Name : EFS012XXXXYYYYOO Temperature : 26°C Relative Humidity : 60 % Pressure : 1015 hPa Test Voltage : AC 120V/60Hz Test Mode : Full Load (5V/2.4A)

Freq. Ant. Reading(RA) Corr.Factor(CF) Measured(FS) Limits(QP) Margin(MHz) H/V (dBuV) (dB) (dBuV/m) (dBuV/m) (dB)47.46 V 30.98 -5.35 25.63 30.00 - 4.3794.99 V 29.51 -9.41 20.10 30.00 - 9.90117.30 V 30.10 -5.93 24.17 30.00 - 5.83 (QP)135.73 V 26.49 -4.63 21.86 30.00 - 8.14 (QP)152.22 V 27.60 -4.39 23.21 30.00 - 6.79223.03 V 32.83 -6.44 26.39 30.00 - 3.61 (QP)

Note

Remark: (1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak

Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW =120KHz, Swp. Time = 0.3 sec./MHz。

(2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes that the Peak reading compliance with the QP Limits and then QP Mode measurement didn‘t perform。

(3) Measuring frequency range from 30MHz to 1000MHz。 (4) If the peak scan value lower limit more than 20dB, then this signal data does not show

in table。

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 30 of 40

E.U.T : Switching Power Supply Model Name : EFS012XXXXYYYYOO Temperature : 26°C Relative Humidity : 60% Pressure : 1015 hPa Test Voltage : AC 120V/60Hz Test Mode : Full Load (5V/2.4A)

Freq. Ant. Reading(RA) Corr.Factor(CF) Measured(FS) Limits(QP) Margin(MHz) H/V (dBuV) (dB) (dBuV/m) (dBuV/m) (dB)

117.30 H 27.33 -5.93 21.40 30.00 - 8.60134.76 H 27.18 -4.68 22.50 30.00 - 7.50218.18 H 32.57 -6.87 25.70 30.00 - 4.30276.38 H 26.84 -3.74 23.10 37.00 - 13.90297.72 H 25.42 -3.02 22.40 37.00 - 14.60389.87 H 23.48 -0.78 22.70 37.00 - 14.30

Note

Remark: (1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak

Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW =120KHz, Swp. Time = 0.3 sec./MHz。

(2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes that the Peak reading compliance with the QP Limits and then QP Mode measurement didn‘t perform。

(3) Measuring frequency range from 30MHz to 1000MHz。 (4) If the peak scan value lower limit more than 20dB, then this signal data does not show

in table。

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 31 of 40

E.U.T : Switching Power Supply Model Name : EFS012XXXXYYYYOO Temperature : 26°C Relative Humidity : 60 % Pressure : 1015 hPa Test Voltage : AC 120V/60Hz Test Mode : Full Load (9V/1.33A)

Freq. Ant. Reading(RA) Corr.Factor(CF) Measured(FS) Limits(QP) Margin(MHz) H/V (dBuV) (dB) (dBuV/m) (dBuV/m) (dB)47.46 V 31.86 -5.35 26.51 30.00 - 3.4957.16 V 26.26 -5.56 20.70 30.00 - 9.3070.74 V 28.55 -7.83 20.72 30.00 - 9.2882.38 V 31.69 -9.45 22.24 30.00 - 7.76101.78 V 34.64 -8.21 26.43 30.00 - 3.57 (QP)135.73 V 29.28 -4.63 24.65 30.00 - 5.35

Note

Remark: (1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak

Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW =120KHz, Swp. Time = 0.3 sec./MHz。

(2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes that the Peak reading compliance with the QP Limits and then QP Mode measurement didn‘t perform。

(3) Measuring frequency range from 30MHz to 1000MHz。 (4) If the peak scan value lower limit more than 20dB, then this signal data does not show

in table。

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 32 of 40

E.U.T : Switching Power Supply Model Name : EFS012XXXXYYYYOO Temperature : 26°C Relative Humidity : 60% Pressure : 1015 hPa Test Voltage : AC 120V/60Hz Test Mode : Full Load (9V/1.33A)

Freq. Ant. Reading(RA) Corr.Factor(CF) Measured(FS) Limits(QP) Margin(MHz) H/V (dBuV) (dB) (dBuV/m) (dBuV/m) (dB)47.46 H 30.25 -5.35 24.90 30.00 - 5.10102.75 H 31.09 -7.99 23.10 30.00 - 6.90116.33 H 26.87 -5.97 20.90 30.00 - 9.10247.28 H 29.38 -4.88 24.50 37.00 - 12.50263.77 H 27.40 -4.30 23.10 37.00 - 13.90277.35 H 26.11 -3.71 22.40 37.00 - 14.60

Note

Remark: (1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak

Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW=120KHz, Swp. Time = 0.3 sec./MHz。

(2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes that the Peak reading compliance with the QP Limits and then QP Mode measurement didn‘t perform。

(3) Measuring frequency range from 30MHz to 1000MHz。 (4) If the peak scan value lower limit more than 20dB, then this signal data does not show

in table。

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 33 of 40

E.U.T : Switching Power Supply Model Name : EFS012XXXXYYYYOO Temperature : 26°C Relative Humidity : 60 % Pressure : 1015 hPa Test Voltage : AC 120V/60Hz Test Mode : Full Load (12V/1A)

Freq. Ant. Reading(RA) Corr.Factor(CF) Measured(FS) Limits(QP) Margin(MHz) H/V (dBuV) (dB) (dBuV/m) (dBuV/m) (dB)48.43 V 29.20 -5.34 23.86 30.00 - 6.14 (QP)101.78 V 28.61 -8.21 20.40 30.00 - 9.60122.15 V 26.42 -5.61 20.81 30.00 - 9.19146.40 V 25.30 -4.48 20.82 30.00 - 9.18221.09 V 27.55 -6.67 20.88 30.00 - 9.12285.11 V 26.53 -3.43 23.10 37.00 - 13.90

Note

Remark: (1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak

Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW =120KHz, Swp. Time = 0.3 sec./MHz。

(2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes that the Peak reading compliance with the QP Limits and then QP Mode measurement didn‘t perform。

(3) Measuring frequency range from 30MHz to 1000MHz。 (4) If the peak scan value lower limit more than 20dB, then this signal data does not show

in table。

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 34 of 40

E.U.T : Switching Power Supply Model Name : EFS012XXXXYYYYOO Temperature : 26°C Relative Humidity : 60% Pressure : 1015 hPa Test Voltage : AC 120V/60Hz Test Mode : Full Load (12V/1A)

Freq. Ant. Reading(RA) Corr.Factor(CF) Measured(FS) Limits(QP) Margin(MHz) H/V (dBuV) (dB) (dBuV/m) (dBuV/m) (dB)47.46 H 30.95 -5.35 25.60 30.00 - 4.40102.75 H 31.39 -7.99 23.40 30.00 - 6.60129.91 H 27.77 -4.87 22.90 30.00 - 7.10203.63 H 31.72 -7.02 24.70 30.00 - 5.30284.14 H 29.87 -3.47 26.40 37.00 - 10.60307.42 H 24.84 -2.74 22.10 37.00 - 14.90

Note

Remark: (1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak

Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW =120KHz, Swp. Time = 0.3 sec./MHz。

(2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes that the Peak reading compliance with the QP Limits and then QP Mode measurement didn‘t perform。

(3) Measuring frequency range from 30MHz to 1000MHz。 (4) If the peak scan value lower limit more than 20dB, then this signal data does not show

in table。

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 35 of 40

E.U.T : Switching Power Supply Model Name : EFS012XXXXYYYYOO Temperature : 26°C Relative Humidity : 60 % Pressure : 1015 hPa Test Voltage : AC 120V/60Hz Test Mode : Full Load (20V/0.6A)

Freq. Ant. Reading(RA) Corr.Factor(CF) Measured(FS) Limits(QP) Margin(MHz) H/V (dBuV) (dB) (dBuV/m) (dBuV/m) (dB)48.43 V 28.60 -5.34 23.26 30.00 - 6.74 (QP)82.38 V 31.31 -9.45 21.86 30.00 - 8.14112.45 V 26.95 -6.15 20.80 30.00 - 9.20139.61 V 28.87 -4.49 24.38 30.00 - 5.62237.58 V 29.17 -5.27 23.90 37.00 - 13.10370.47 V 23.38 -1.18 22.20 37.00 - 14.80

Note

Remark: (1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak

Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW =120KHz, Swp. Time = 0.3 sec./MHz。

(2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes that the Peak reading compliance with the QP Limits and then QP Mode measurement didn‘t perform。

(3) Measuring frequency range from 30MHz to 1000MHz。 (4) If the peak scan value lower limit more than 20dB, then this signal data does not show

in table。

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 36 of 40

E.U.T : Switching Power Supply Model Name : EFS012XXXXYYYYOO Temperature : 26°C Relative Humidity : 60% Pressure : 1015 hPa Test Voltage : AC 120V/60Hz Test Mode : Full Load (20V/0.6A)

Freq. Ant. Reading(RA) Corr.Factor(CF) Measured(FS) Limits(QP) Margin(MHz) H/V (dBuV) (dB) (dBuV/m) (dBuV/m) (dB)47.46 H 29.65 -5.35 24.30 30.00 - 5.70112.45 H 28.25 -6.15 22.10 30.00 - 7.90149.31 H 30.79 -4.49 26.30 30.00 - 3.70264.74 H 28.75 -4.25 24.50 37.00 - 12.50341.37 H 24.74 -1.84 22.90 37.00 - 14.10367.56 H 24.95 -1.25 23.70 37.00 - 13.30

Note

Remark: (1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak

Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW =120KHz, Swp. Time = 0.3 sec./MHz。

(2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes that the Peak reading compliance with the QP Limits and then QP Mode measurement didn‘t perform。

(3) Measuring frequency range from 30MHz to 1000MHz。 (4) If the peak scan value lower limit more than 20dB, then this signal data does not show

in table。

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 37 of 40

E.U.T : Switching Power Supply Model Name : EFS012XXXXYYYYOO Temperature : 26°C Relative Humidity : 60 % Pressure : 1015 hPa Test Voltage : AC 120V/60Hz Test Mode : Full Load (24V/0.5A)

Freq. Ant. Reading(RA) Corr.Factor(CF) Measured(FS) Limits(QP) Margin(MHz) H/V (dBuV) (dB) (dBuV/m) (dBuV/m) (dB)51.34 V 30.24 -5.37 24.87 30.00 - 5.13 (QP)74.62 V 31.78 -8.41 23.37 30.00 - 6.63112.45 V 26.38 -6.15 20.23 30.00 - 9.77146.40 V 26.93 -4.48 22.45 30.00 - 7.55 (QP)157.07 V 29.24 -4.17 25.07 30.00 - 4.93210.42 V 28.81 -7.12 21.69 30.00 - 8.31

Note

Remark: (1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak

Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW =120KHz, Swp. Time = 0.3 sec./MHz。

(2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes that the Peak reading compliance with the QP Limits and then QP Mode measurement didn‘t perform。

(3) Measuring frequency range from 30MHz to 1000MHz。 (4) If the peak scan value lower limit more than 20dB, then this signal data does not show

in table。

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 38 of 40

E.U.T : Switching Power Supply Model Name : EFS012XXXXYYYYOO Temperature : 26°C Relative Humidity : 60% Pressure : 1015 hPa Test Voltage : AC 120V/60Hz Test Mode : Full Load (24V/0.5A)

Freq. Ant. Reading(RA) Corr.Factor(CF) Measured(FS) Limits(QP) Margin(MHz) H/V (dBuV) (dB) (dBuV/m) (dBuV/m) (dB)51.34 H 25.67 -5.37 20.30 30.00 - 9.7076.56 H 29.60 -8.70 20.90 30.00 - 9.10146.40 H 26.28 -4.48 21.80 30.00 - 8.20158.04 H 24.43 -4.13 20.30 30.00 - 9.70212.36 H 29.16 -7.06 22.10 30.00 - 7.90320.03 H 25.11 -2.41 22.70 37.00 - 14.30

Note

Remark: (1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak

Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW =120KHz, Swp. Time = 0.3 sec./MHz。

(2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes that the Peak reading compliance with the QP Limits and then QP Mode measurement didn‘t perform。

(3) Measuring frequency range from 30MHz to 1000MHz。 (4) If the peak scan value lower limit more than 20dB, then this signal data does not show

in table。

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 39 of 40

5. EUT TEST PHOTO

Conducted Measurement Photos

Neutron Engineering Inc.

Report No.: NEI-FCCE-1-0904C096 Page 40 of 40

Radiated Measurement Photos