4
NEUROENDOSCOPY W H E N P R E C I S I O N M A T T E R S NeuroPEN ChannelScope

NEUROENDOSCOPY - Clarus Medical LLC · Light Cable, ACMI-Olympus, 1 mm Graspers, 2.0 mm, 19.7 cm Long Light Cable, ACMI-Wolf/Dyonics, 1 mm Graspers, 2.0 mm, 28.5 cm Long Light Cable,

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: NEUROENDOSCOPY - Clarus Medical LLC · Light Cable, ACMI-Olympus, 1 mm Graspers, 2.0 mm, 19.7 cm Long Light Cable, ACMI-Wolf/Dyonics, 1 mm Graspers, 2.0 mm, 28.5 cm Long Light Cable,

N E U R O E N D O S C O P YW H E N P R E C I S I O N M A T T E R S

NeuroPEN

ChannelScope

Page 2: NEUROENDOSCOPY - Clarus Medical LLC · Light Cable, ACMI-Olympus, 1 mm Graspers, 2.0 mm, 19.7 cm Long Light Cable, ACMI-Wolf/Dyonics, 1 mm Graspers, 2.0 mm, 28.5 cm Long Light Cable,

S I N G L E - U S E N E U R O E N D O S C O P E SV I S U A L C O N F I R M A T I O N • E A S Y T O U S E

N e u r o P E N

S p e c i f i c a t i o n s

Designed for ventricular catheter placement.

Stylet handle enables unencumbered placement of ventricular catheters away from the choroid plexus and other anatomical structures.

Irrigation channel maintains clear field of view.

Small 1.1mm diameter endoscope.

2120-025

MODEL

2120-025 NeuroPEN, 15.5 cm Shaft

DESCRIPTION

Image

Illumination

IrrigationPort

1.1mmO.D.

15.5 cm

Endoscope

NeuroPEN

Page 3: NEUROENDOSCOPY - Clarus Medical LLC · Light Cable, ACMI-Olympus, 1 mm Graspers, 2.0 mm, 19.7 cm Long Light Cable, ACMI-Wolf/Dyonics, 1 mm Graspers, 2.0 mm, 28.5 cm Long Light Cable,

M I N I M I Z E C R O S S C O N T A M I N A T I O N R I S KL I G H T W E I G H T • C O S T E F F E C T I V E

C h a n n e l S c o p e

S p e c i f i c a t i o n s

Designed for intraventricular surgery.

Lightweight design removes the bulk and weight of the camera away from the hand.

High resolution endoscopes with 30,000 pixel fibers provide consistent, high-quality imagery.

The fiberoptic design permits the endoscope to be held in a retractor arm with minimal risk of damage to the optics.

Single use endoscopes eliminate costs associated with reprocessing or repair.

MODEL

2233-002

2233-005

1305-014

30K ChannelScope, 21.6 cm Shaft, WC Diameter 2 mm

30K ChannelScope, 13 cm Shaft, WC Diameter 2 mm

Peelaway Introducer Sheath, 14 FR, 5-Pack

DESCRIPTION

Image

2.13 mm I.D.Working Channel

Tip View 2233-005 and 2233-002

4.2 mm O.D.

Working Channel

Irrigation Channel

Illumination

13.0 cm or 21.6 cm

14 FR Peelaway Introducer Sheath(Needed for 2233-002 or 2233-005)

ChannelScope

Page 4: NEUROENDOSCOPY - Clarus Medical LLC · Light Cable, ACMI-Olympus, 1 mm Graspers, 2.0 mm, 19.7 cm Long Light Cable, ACMI-Wolf/Dyonics, 1 mm Graspers, 2.0 mm, 28.5 cm Long Light Cable,

A C C E S S O R I E S

Dia. 2.0 mm

19.7 cm or 28.5 cm

Cup Jaw Grasping Jaw

Optical CouplerREF No. 5189-001

Expansion RingREF No. 5189-901

EyepieceREF No. 5188-001

C L A R U S M E D I C A L , L L C | 7 6 3 . 5 2 5 . 8 4 0 3 | A D M I N @ C L A R U S - M E D I C A L . C O M

MODEL

MODEL

3221-002

5154-100

3220-002

5160-100

3241-002

5161-100

3240-002

5163-100

Forceps, Cup, 2 mm, 19.7 cm Long

Light Cable, ACMI-Storz, 1 mm

Forceps, Cup, 2 mm, 28.5 cm Long

Light Cable, ACMI-Olympus, 1 mm

Graspers, 2.0 mm, 19.7 cm Long

Light Cable, ACMI-Wolf/Dyonics, 1 mm

Graspers, 2.0 mm, 28.5 cm Long

Light Cable, ACMI-ACMI, 1 mm

DESCRIPTION

DESCRIPTION

V i d e o A d a p t e r s L i g h t C a b l e s(Type needed depends on camera)

910160-001-A