InnovationsCatalogue 2009/2010
positionsensors
and objectrecognition
fluid sensorsand diagnostic
systems
bus,identification
and control systems
2
*Some offered information is available country-specific.
www.ifm.comInformation around the clock andaround the globe in 22 languages on the internet.
• Information- product innovations- company news- exhibition info- locations- jobs
• Documentation- data sheets- operating instructions- manuals- approvals- CAD data
• Communication*- request for documents- recall service- live advice- newsletter
• Selection- interactive product selection aids- configuration tools- data sheet direct
• Animation- virtual product animations- flash movies (video sequences)
• Application- applications- product recommendations- calculation aids
• Transaction*- e-shop processing- e-procurement catalogues- B2B services
3
Convenient order processingvia the e-shop** on the internet.
Secured authentication
Customer-related priceindication
Real time availability check
Personal product favourites
Online parcel tracking
Individual order history
Convenient quick input form
Simple order processing
Management of shippingaddresses
Confirmations by e-mail
**Already available in many countries.
4
Position sensors andobject recognition
... for hazardous areas: robust all around (11.2009)
... ring and tube sensors (11.2009)
... slot sensors - small, low price and versatile (11.2009)
... full metal housing sensors for heavy duty (04.2009)
Inductive sensors
Capacitive sensors
... ready for use at the push of a button (04.2009)
Magnetic sensors, cylinder sensors
… the low-cost alternative – T-slot reed sensors (11.2009)
Safety technology
... M30 design for direct detection of metal (11.2009)
… safety relays for the protection of operators and machinery (11.2009)
Valve sensors
... valve position in a new light (11.2009)
... the powerful O7 – small, compact, precise (11.2009)
... the new safety light curtains and safety light grids (11.2009)
... robust optical angle sensors and optical fork sensors (04.2009)
... the OG BasicLine now also in plastic (11.2009)
... OG wetline with cable connection (04.2009)
... for ATEX 3D: type O5 (04.2009)
... O5 now also available as cable version (04.2009)
... the new O4 now also with cable connection (04.2009)
... the new generation of OBF fibre optic amplifiers (04.2009)
Photoelectric sensors
... a quantum leap in optoelectronics: O3D vision sensor (04.2009)
... O3D camera: detection of objects and scenes in 3 dimensions (04.2009)
Object recognition
Flow sensors
... compact flow monitoring in hygienic areas (11.2009)
... magnetic-inductive flow sensor efector mid (11.2009)
... control monitor for the connection of flow sensors (11.2009)
... safe measurement of smallest quantities: the new SQ design (04.2009)
... ultrasonic flow rate sensor in robust inline design (04.2009)
... the new mechatronic flow sensors: SBU, SBY (04.2009)
Fluid sensorsand diagnostic systems
... the new generation of CANopen encoders (11.2009)
Encoders
6 - 78 - 9
10 - 1112 - 15
16 - 17
18 - 19
20 - 2122 - 23
24 - 25
26 - 2728 - 3132 - 3334 - 3536 - 3738 - 3940 - 4142 - 4344 - 45
52 - 5354 - 5556 - 5758 - 5960 - 6162 - 65
46 - 4748 - 49
50 - 51
5
... AS-i module with two IO-Link ports (04.2009)
... ATEX modules with quick mounting technology (04.2009)
Bus system AS-InterfaceBus systems
Connection technology Connection technology
... ecolink M12 for ATEX applications (11.2009)
... calibration-free transmitters with Profibus PA and ATEX (11.2009)
Temperature sensors
... diagnostic electronics for vibration sensors (11.2009)
... permanent machine protection made easy (04.2009)
... miniaturised vibration sensor efector octavis (04.2009)
... simply combined: machine protection and trend analysis (04.2009)
Diagnostic systems
Fluid sensorsand diagnostic systems
... a breath of fresh air in pneumatics, the pressure sensor PQ (11.2009)
... the new electronic contact manometer PG (04.2009)
... full-metal pressure sensors for hygienic applications (04.2009)
... the PK series: now also with one switching output (04.2009)
... small and at a low cost - the new pressure sensor PT (04.2009)
Pressure sensors
... multicode reader with infrared illumination (11.2009)
Multicode reading systems
... 32-bit ExtendedController for mobile vehicles (11.2009)
Control systems for mobile vehicles
Identification systems
Control systems
For further technical data please go to: www.ifm.com
88 - 8990 - 91
86 - 87
76 - 77
78 - 7980 - 8182 - 8384 - 85
66 - 6768 - 6970 - 7172 - 7374 - 75
92 - 93
94 - 95
6
Category 3D (zone 22) andcategory 3G (zone 2).
RectangularThe sensors of the IMC rectangular design are particularlysuited for use in conveying. The two clearly visible LEDsindicating the sensing and operating states can be seeneven under adverse installation conditions.
UnbeatableBoth the threaded body and the sensing face of the hous-ing are made of stainless steel.
Uniqueifm connectors of the ecolink series comply with the strictstandard requirements and may be used in hazardousareas of the categories 2D, 3D and 3G.
product news
Full-metal threaded housings fromM12 to M30.
Rectangular designs with sensing rangesup to 40 mm.
M12 ecolink connectors for a secureconnection.
High vibration and shock resistance.
Versions in 3 and 4-wire technology.
Inductive sensors for hazardousareas: Robust all around.
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
7
11.2009
Wiring diagram
L+
L
1
4
3
5957
50
M18
x1
4
M12
x1
70
24LED 4 x 90°
Dimensions
Accessories
Type Sensingrange [mm]
Ambienttemperature
[°C]
f
[Hz]
Housing material Orderno.
M12 connector · output function complementary · 4-wire DC PNP
rectangular 20 f 0...50100 PA IM504A
DimensionsLength[mm]
40 x 40
rectangular 40 nf 0...50100 PA IM503A40 x 40
M12 connector · output function · 3-wire DC PNP
M12 3 f 0...60100 high-grade stainless steel IF502AL = 60
M18 5 f 0...60100 high-grade stainless steel IG509AL = 70
M30 10 f 0...6050 high-grade stainless steel II501AL = 70
Applications:Silo hatches, elevators, etc.
IG509A
4940
M12
x1
174
M12
x1
LED 4 x 90°
60 IF502A
58
50
M30
x1,5
5
57
70
36
M12
x1
LED 4 x 90°
II501A
40
66
40
54
M12
x130
30 2
2
1
46
46
5,5
5,5
29,5
IM503A / IM504A
Angle bracket for type M30,stainless steel E10737
Angle bracket for type M12,stainless steel E10735
Angle bracket for type M18,stainless steel E10736
Mounting set, straight for clampmounting, high-grade stainless steel E11120
Connectors and splitter boxes
Type Description Orderno.
Socket, M12, 4-pole,2 m black, PUR cable EVC04A
Socket, M12, 4-pole,5 m black, PUR cable EVC05A
Connection cable, M12, 4-pole,2 m black, PUR cable EVC07A
Connection cable, M12, 4-pole,5 m black, PUR cable EVC12A
4
L
L+1
2
32:4:
Mounting set, angled for clampmounting, high-grade stainless steel E11119
1) LED yellow2) LED green
IF502A, IG509A, II501A IM503A, IM504A
Inductive sensors
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
For further technical data please go to: www.ifm.com
Type Description Orderno.
8
Inductive ring andtube sensors.
Static sensors operate like inductive proximity sensors.They generate an output signal as long as there is metalin the detection zone. So, feed processes for example withfalling screws or jam monitoring can be implemented.Dynamic sensors are used when particularly small partsare to be detected. During a damping operation a shortpulse is generated at the output of the sensor, adjustablefrom 0.1 to 150 ms. The high resolution is maintainedfor a long time even in case of metal contamination onthe tube.
product news
Static and dynamic versions.
High resolution: even steel balls withØ 0.6 mm are reliably detected.
Extremely quick with a response time of0.2 ms.
Pulse stretching and sensitivity adjustablevia potentiometer.
Choice between normally closed ornormally open.
Keep track of detail –detection of small metal parts.
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
9
11.2009
Operating voltage [V DC] 10…35
Current rating [mA] 200
Current consumption [mA] < 25
Voltage drop [V] < 2
Ambient temperature [°C] -25...70
Protection IP 67
Common technical data
Ring sensors
Ringdiameter
[mm]
Orderno.
M12 connector · Output function · 3-wire DC PNP
I7R20110.1
Operatingprinciple
static
ResolutionSteel ball[Ø mm]
1.5
Pulsestretching
[ms]
10...150
Response time /fall time
[ms]
0.5 / 10
I7R20310.1 dynamic 0.6 0.1...150 0.2 / 0.2
M12 connector · Output function · 3-wire DC NPN
I7R20210.1 static 1.5 10...150 0.5 / 10
Partspeed[ms]
< 35
< 35
I7R20515.1 static 2 10...150 0.5 / 10< 35
I7R20715.1 dynamic 0.8 0.1...150 0.2 / 0.2< 35
I7R20920.1 static 2.5 10...150 0.5 / 10< 35
I7R21120.1 dynamic 1 0.1...150 0.2 / 0.2< 35
I7R21325.1 static 3 10...150 0.5 / 10< 35
I7R21525.1 dynamic 1.2 0.1...150 0.2 / 0.2< 35
< 35
I7R20410.1 dynamic 0.6 0.1...150 0.2 / 0.2< 35
I7R20615.1 static 2 10...150 0.5 / 10< 35
I7R20815.1 dynamic 0.8 0.1...150 0.2 / 0.2< 35
I7R21020.1 static 2.5 10...150 0.5 / 10< 35
I7R21220.1 dynamic 1 0.1...150 0.2 / 0.2< 35
I7R21425.1 static 3 10...150 0.5 / 10< 35
I7R21625.1 dynamic 1.2 0.1...150 0.2 / 0.2< 35
Sensing range
[mm]
Orderno.
M8 connector · Output function · 3-wire DC PNP
I8500014
Operatingprinciple
static
ResolutionSteel ball[Ø mm]
3
Pulsestretching
[ms]
100
Response time /fall time
[ms]
0.5 / 100
I8500420 dynamic 1 100 0.2 / 100
Partspeed[ms]
< 35
< 35
M8 connector · Output function · 3-wire DC NPN
I8500114 static 3 100 0.5 / 100
I8500520 dynamic 1 100 0.2 / 100
< 35
< 35
M12 cable plug 0.09 m · Output function · 3-wire DC PNP
I8500214 static 3 100 0.5 / 100
I8500620 dynamic 1 100 0.2 / 100
< 35
< 35
M12 cable plug 0.09 m · Output function · 3-wire DC NPN
I8500314 static 3 100 0.5 / 100
I8500720 dynamic 1 100 0.2 / 100
< 35
< 35
Tube sensors
Connectors and splitter boxes
Type Description Orderno.
Socket, M12,2 m black, PUR cable EVC001
Socket, M12,5 m black, PUR cable EVC002
Socket, M12,2 m black, PUR cable EVC004
Socket, M12,5 m black, PUR cable EVC005
Inductive sensors
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
For further technical data please go to: www.ifm.com
10
Precise position detection forinstrumentation.
ApplicationsApplications for slot sensors can be found on measur-ing devices or instruments for metering pressures and flowrates. The sensors can be installed individually and ensurewear-free and non-contact switching. The sensor targetcan be made of different materials.
Typical applications:In a meter the sensor detects slots in a disc. In a vane-typeflow meter the pointer counterweight position is detectedby slot sensors.
VersionsThe new inductive slot sensors are approved for Cat-egory 1 ATEX gas and dust areas. The sensors can beoperated outside ATEX areas with 24 V.
product news
Standardised housing for easyinstallation.
Approvals to ATEX and IECEx.
Namur interface.
Wide temperature range.
Inductive slot sensors –small, low price and versatile.
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
11
11.2009
Operating voltage [V DC] 8.2
Current consumption [mA] < 1.2
Operating voltage [V]outside the hazardous area 5...25 DC
Immersion depth (side) [mm] 5...7
Slot sensors Slot width 2 mm and 3.5 mm
Wiring diagram
+BN
BU
82
15
1,5
1111
6
15
3,7
Dimensions
Type Description Orderno.
Accessories
Applications:fittings, measurement devices, valve boxes
Common technical data
N7S20A
195
3,5
15 102
1,8
10
N7S21A
ATEX category Orderno.
2-wire DC PNP
N7S20AII 1 D, 1 G
Slot width
[mm]
2
Ambienttemperature
[°C]
-40...100
Protection
IP 67, III
f
[Hz]
5000
N7S21AII 1 D, 1 G 3.5 -40...100 IP 67, III 3000
Housing:material
PBT
PBT
N7S23AII 1 D, 1 G 3.5 -40...100 IP 67, III 3000PBT
3
2
N7S20A, N7S23A N7S21A
N0033A2 channelrelay outputs
N0532A2 channel
optocoupleroutput
N0534A2 channeltransistorOutputs
N0530A1 channelrelay output
Switching amplifiers with ATEX approval
Inductive sensors
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
For further technical data please go to: www.ifm.com
12
Extremely resistant, excellentprice/performance ratio inM8 to M30 housings.
Ideal for metalworking applications.
Devices and connectors:adapted for use in oils.
Strong sensing face is resistant toimpacts.
Vibration and shock resistant.
Lasered type label: permanently legible.
MaterialsThe threaded body and the sensing face of the housingare made of stainless steel.
Oils and coolantsOils and coolants heavily impact the installed machinecomponents. The O-ring seal made of Viton combinedwith the corresponding ecolink connector ensures highprotection against malfunctions.
Application testsA series of tests qualified the sensors for use in harsh en-vironments:• Vibration test• Shock test• Impact test• Coolant test
Simply unbeatable!Full metal inductive sensors:
product news
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
13
04.2009
Operating voltage [V DC] 10...36
Current consumption [mA] < 20
Short-circuit protection, pulsed •
Reverse polarity / overload protection • / •
Voltage drop [V] < 2.5
Protection IP 67, IP 68 / III
Function displaySwitching status LED yellow (4 x 90°)
TypeIEC, IFC, IGC, IIC
Wiring diagram
L+
L
1
4
3
Dimensions
Type Description Orderno.
Accessories
Type Sensingrange[mm]
Ambienttemperature
[°C]
f
[Hz]
Iload
[mA]
Housing material Orderno.
M12 connector · output function · 3-wire DC PNP
M12 3 f -25...70100 100high-grade stainless steel IFC258
M18
DimensionsLength[mm]
L = 60
L = 70 5 f -25...70100 100high-grade stainless steel IGC248
M30 L = 70 10 f -25...7050 100high-grade stainless steel IIC224
Applications:Machine tools in combination with oils and coolants.
Common technical data
Angle bracket for type M30,stainless steel E10737
Mounting clip for type M12,stainless steel E11533
Mounting clip for type M18,stainless steel
Angle bracket for type M12,stainless steel E10735
Angle bracket for type M18,stainless steel E10736
E11534
Mounting clamp M12, PC E11047
Mounting clamp M18, PC E11048
Mounting clamp M30, PC E11049
Connectors and splitter boxes
Type Description Orderno.
M12 socket,2 m black, PUR cable EVC001
M12 socket,5 m black, PUR cable EVC002
M12 socket,2 m black, PUR cable EVC004
M12 socket,5 m black, PUR cable EVC005
Inductive sensors
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
For further technical data please go to: www.ifm.com
4940
M12
x1
174
M12
x1
LED 4 x 90°
60 IFC258
3042,5
M8x
1
4
13
M8x
1
LED 4 x 90°
50 IEC201
M18
x1
M12
x1
5057
7059
424LED 4 x 90°
IGC248
58
50
M30
x1,5
5
57
70
36
M12
x1
LED 4 x 90°
IIC224
M8 2 f -25...70100 100high-grade stainless steel IEC200L = 60
M8 connector · output function · 3-wire DC PNP
M8 2 f -25...70100 100high-grade stainless steel IEC201L = 50
14
Tough: extremely resistantin M8 to M30 housings.
Ideal for metalworking applications.
Non-stick coating against weld spatter.
Mechanically resistant to impacts onthe sensing face.
Vibration and shock resistant.
Lasered type label: permanently legible.
MaterialsThe threaded body and the sensing face of the housingare made of stainless steel.
Use in welding applicationsThe non-stick coating allows weld spatter to roll off thesensor. The high temperature range of up to 85 °C meansit can handle critical applications.
Application testsA series of tests qualified the sensors for tough applica-tions:• vibration test• shock test• impact test• wire brush test
sensors for heavy duty.Full metal housing inductive
product news
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
15
04.2009
Operating voltage [V DC] 10...36
Current consumption [mA] < 20
Short-circuit protection, pulsed •
Reverse polarity / overload protection • / •
Voltage drop [V] < 2.5
Protection rating IP 67
Function displaySwitching status LEDOperating status LED
yellow (4 x 90°)green
TypeIFR, IGR, IIR
Wiring diagram
L+
L
1
4
3
Dimensions
Type Description Orderno.
Accessories
Type Sensingrange[mm]
Ambienttemperature
[°C]
f
[Hz]
Iload
[mA]
Housing material Orderno.
M12 connector · output function · 3-wire DC PNP
M12 4 f 0...852 100high-grade stainless steel IFR200
M18
DimensionsLength[mm]
L = 60
L = 70 6 f 0...852 100high-grade stainless steel IGR200
M30 L = 70 12 f 0...852 100high-grade stainless steel IIR200
Applications:Metalworking and welding applications
Common technical data
Angle bracket for type M30,stainless steel E10737
Mounting clip for type M12,stainless steel E11533
Mounting clip for type M18,stainless steel
Angle bracket for type M12,stainless steel E10735
Angle bracket for type M18,stainless steel E10736
E11534
Mounting clamp M12, PC E11047
Mounting clamp M18, PC E11048
Mounting clamp M30, PC E11049
Inductive sensors
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
For further technical data please go to: www.ifm.com
M8 2 f 0...85100 100high-grade stainless steel IER200L = 60
4940
M12
x1
174
M12
x1
LED 4 x 90°
60 IFR200
M8x
1
4
13
M12
x1
6049
33
LED 4 x 90°
IER200
M18
x1
M12
x1
5057
7059
424LED 4 x 90°
IGR200
58
50
M30
x1,5
5
57
70
36
M12
x1
LED 4 x 90°
IIR200
Connectors and splitter boxes
Type Description Orderno.
M12 socket,2 m grey, PUR cable
M12 socket,5 m grey, PUR cable
M12 socket,2 m grey, PUR cable
M12 socket,5 m grey, PUR cable
EVW001
EVW002
EVW004
EVW005
16
product news
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
Capacitive sensor reducestype versions.
Easy pushbutton adjustment inthe application.
Automatic detection of PNP or NPNoutput loads.
Normally open / normally closedfreely selectable.
Clearly visible indication of theswitching status.
Easy mounting using fastening strips.
Detection of liquids on a bypass.
ApplicationCapacitive sensors detect bulk materials or liquids throughnon-metallic materials.The capacitive sensors of the KQ series can either be fixedon a flat surface or on tubes using mounting brackets andcable ties.Using optional accessories the sensors can be integratedinto a wide range of applications in a flexible and time-saving way.
Set-upThe new operating concept enables setting and adjust-ment of the output function by pressing just one push-button. The automatic detection of the load simplifiesthe connection to common controllers.
of a button.Ready for use at the push
17
04.2009
Capacitive sensors
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
For further technical data please go to: www.ifm.com
Applications:Detection of bulk material and liquids through non-metallic vessel walls
Type
[mm]
Sensingrange[mm]
Output functionProtectionTeachbutton
Output stage Orderno.
Connection cable 2 m PVC · 3 wires
48 x 20 x 14 12 nf programmableIP 65, IP 67, III• PNP / NPN* KQ6001
48 x 20 x 14 12 nf programmableIP 65, IP 67, III• PNP KQ6002
Connection cable with M8 plug · 3 wires
48 x 20 x 14 12 nf programmableIP 65, IP 67, III• PNP / NPN* KQ6003
48 x 20 x 14 12 nf programmableIP 65, IP 67, III• PNP KQ6004
Connection cable with M12 plug · 3 wires
48 x 20 x 14 12 nf
Settingrange[mm]
3...20
3...20
3...20
3...20
3...20 programmableIP 65, IP 67, III• PNP KQ6005
Operating voltage [V DC] 10...36
Current rating [mA] 100
Voltage drop [V] < 2.5
Switching frequency [Hz] 10
Switch point drift of Sr [%] ± 20
Switching hysteresis of Sr [%] 1...15
Short-circuit protection, pulsed •
Reverse polarity / overload protection • / •
Ambient temperature [°C] -25...80
Switching status LED yellow
EMC EN 60947-5-2
Material housingcover
pushbuttons
PBT reinforced glass fibrePC reinforced glass fibre
TPE-U
Further technical dataWiring diagram
Type Description Orderno.
Mounting adapter for free-standingmounting, PBT, pack quantity 1 piece E12153
Mounting adapter for free-standingmounting, PBT, pack quantity 10 pieces E12154
E12163
Accessories
* automatic detection of the load
Mounting adapter for pipe and tubemounting, PA, pack quantity 1 piece
E10880Fixing strap in connection with E12163,PA, pack quantity 5 pieces
Connectors and splitter boxes
Type Description Orderno.
M12 socket,2 m black, PUR cable EVC001
M12 socket,5 m black, PUR cable EVC002
M8 socket, 4 poles,2 m black, PUR cable E11199
M8 socket, 4 poles,5 m black, PUR cable E11200
Connection cable, M12, 4 poles,0.3 m black, pin 3: L+ pin 1: L- E11974
Connection cable, M8, 4 poles,0.2 m black, pin 3: L+ pin 1: L- E12155
KQ6002 KQ6004, KQ6005
KQ6001
KQ6003
L
L+BN
BK
BU L
L+BN
BK
BU
BN
BK
BU
L+
L
L+
L
1
4
3
L+
L
1
4
3
L+
L
1
4
3
18
T-slot cylinder sensors forthe AC/DC voltage range upto 120 V.
One reed contact for standard applicationsA reed element now also belongs to the family of T-slotcylinder sensors. Its response sensitivity to magnetic fieldchanges is comparable to that of common electroniccylinder sensors.
Good fixing and easy installationThe ifm sensor has the following advantages: it can belocked in the T-slot by its self-locking mechanism. Further-more, the fixing at the end of the housing allows excellentstrain relief.
Adapters for almost any cylinder profileThanks to the wide selection of adapter accessories theT-slot sensor can be fixed to almost every clean-line, tierod, integrated profile or trapezoidal slot cylinder.
product news
Connection as 2-wire PNP/NPN possible.
Wide temperature range of -25...70 °C.
Connection via cable, M8 or M12connector.
Self-locking mechanism for easysingle-handed installation.
Convenient: easy and quick fit “drop fromthe top” into a slot.
The low-cost alternative.T-slot reed sensors.
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
19
11.2009
Connection cable 2 m PUR · output function · 2-wire
Connection cable 0.3 m PUR with M8 connector rotatable · output function · 2-wire
Applications: T-slot cylinder sensors for use in industrial environments such as packagingor handling machines.
Type / Dimensions
[mm]
Electrical design Ambienttemperature
[°C]
Iload
[mA]
Housing material Orderno.
Connection cable 0.3 m PUR with M8 connector · output function · 2-wire
30.5 x 5 x 5 AC/DC, PNP/NPN -25...70 100PA, stainless steel MR0101
30.5 x 5 x 5 AC/DC, PNP/NPN -25...70 100PA, stainless steel MR0102
Connection cable 6 m PUR · output function · 2-wire
30.5 x 5 x 5 AC/DC, PNP/NPN -25...70 100PA, stainless steel MR0117
30.5 x 5 x 5 AC/DC, PNP/NPN -25...70 100PA, stainless steel MR0100
Connection cable 0.3 m PUR with M12 connector · output function · 2-wire
30.5 x 5 x 5 AC/DC, PNP/NPN
Operating voltage
[V]
5...50 AC / 5...60 DC
5...50 AC / 5...60 DC
5...120 AC/DC
5...120 AC/DC
5...120 AC/DC -25...70 100PA, stainless steel MR0107
L 30,5
5
M8x
1
37 6,5
5,1
5,71
Dimensions
LED display yellow
Repeatability [mm] ± 0.2
Switching frequency [Hz] 1000
Short-circuit protection –
Reverse-polarity protection –
Protection IP 67, II
Travel speed [m/s] > 10
Response sensitivity [mT] 2.1
Hysteresis [mm] typ. 1
Common technical data
1) fastening clamp
Connectors and splitter boxes
Type Description Orderno.
Socket, M8, 3-pole,2 m black, PUR cable E11486
Socket, M8, 3-pole,5 m black, PUR cable E11487
Socket, M8, 3-pole,2 m black, PUR cable E11489
Socket, M8, 3-pole,5 m black, PUR cable E11490
Example MR0101
Splitter box M8, 8 locations,5 m black, PUR cable, LED E11214
Accessories
Type Description Orderno.
Memorisation block for T-slot,PA, stainless steel E11798
Adapter for trapezoidal slot cylinders,aluminium alloy E11988
Adapter for tie rod / profile cylinders,clamping range 5...11 mm, aluminium E11797
Adapter for tie rod / profile cylinders,clamping range 9...15 mm, aluminium E11799
Adapter for SMC cylinders ECDQ2 series,aluminium E11890
Adapter for SMC cylinders CDQ2 series,aluminium E11891
Magnetic sensors,cylinder sensors
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
For further technical data please go to: www.ifm.com
20
Detection withoutmagnetic targetor coded actuator.
Requirement profiles for the fail-safe sensor:Reliable positioning on rotary indexing tables and machinetools. Reliable triggering of slow travel or switching offin end positions for presses, gantry robots and actuators.Reliable area monitoring for robots.The fail-safe sensor increases the uptime and safety ofyour installation and can be connected to certified safetyrelays without cross fault monitoring.Wear-free operation guarantees low maintenance costsof your installation. Faults such as coil break or coil shortcircuit are diagnosed and the sensor passes into the de-fined safe state. Even a cross fault between the supplyvoltage and one of the two outputs does not affect thesafety function of the sensor.
product news
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
Suitable for operator and machine safety.
Reliable end position monitoring onmoving machine parts.
Convenient connection to safety PLC,bus systems and logic.
No wear:maximum machine uptime and safety.
Certified to IEC 62061 SILcl2, ISO 13849-1PL d, complies with IEC 61508 SIL2.
Fail-safe inductive sensordirectly detects metal.
21
11.2009
Technical data (extract)
Certified to IEC 62061 SILcl2 and ISO 13849-1Complies with the requirements to IEC 61508 SIL2
Inductive safety applications are special applications which require a non-contact andsafe detection of a metal object.
M12 connector · Output function 2 PNP no (OSSD)
Type /design
Enable zone
[mm]
Protectionrating
Current rating
[mA]
Safety-related reliability(to IEC 61508)
Ambienttemperature
[°C]
Orderno.
M30 / nf 1001...15 GI711SIP 65 / IP 67 PFDavg < 1 x 10-3 / PFHD < 1,0 x 10-7/h -25...70
M30 / f 1001...10 GI712SIP 65 / IP 67 PFDavg < 1 x 10-3 / PFHD < 1,0 x 10-7/h -25...70
Category is history – now there is SIL and PL.In the past you were familiar with categorisation to EN954-1, this has been replaced by SIL and IEC 62061 andPL to ISO 13849-1.The qualitative approach is no longer sufficient so thequantitative approach has been added. The standardsIEC 62061 and ISO 13849-1 now consider also the aver-age probability of failure of components (called prob-abilistic approach).The new approaches have been developed also becausethe EN 954-1 did not take into account the time behav-iour (e.g. test interval, life time).These characteristics of the sensors or the individualcomponents are described in the Safety Integrity Level(SIL 1-3) and the Performance Level (PL a-e).ifm offers you “safe” assistance, today as well as in thefuture. www.ifm.com/gb/safeYou can find more information on the standards at:www.zvei.org or www.vdma.org
Evaluation unit
Type Description Orderno.
G1501SSafety relay
Relay outputs
G1503SSafety relay
Semiconductoroutputs
(BK)
3
1
4
2
L+
L
(BN)
A2
A1
(BU)
(WH)+24 V
IN1
GND
IN2
1
Wiring diagram
1) Evaluation unit or PLC
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
Safety technology
For further technical data please go to: www.ifm.com
Connectors and splitter boxes
Type Description Orderno.
M12 socket,2 m black, PUR cable EVC001
M12 socket,5 m black, PUR cable EVC002
M12 socket,2 m black, PUR cable EVC004
M12 socket,5 m black, PUR cable EVC005
Operating voltage [V] 24 DC (19.2...30 DC)
Short-circuit protection •
Reverse polarity protection •
Operating mode Permanent operation(maintenance-free)
Service life T [h] 87600(10 years)
Test interval T1 [h] = service life T
Status indication LEDSwitching statusOperating voltage
yellowgreen
22
Multifunctional withsemiconductor outputssuitable for your applications.
Options for connection to the G1503S
light barriers/ light curtains
two-hand control
ifm fail -safe sensors
E-stop protective guards
There are versatile options for connection to the safetyrelay. It performs monitoring tasks in safety applicationsin combination with different non-contact guards.The evaluation of the signals from safety light barriers,safety light curtains, electronic fail-safe sensors or me-chanical safety switches for protective guard contactsor electronic position sensors or mechanical positionswitches with or without cross-fault monitoring are onlya few applications.The safety relay has several multifunctional self-detect-ing and self-monitoring short-circuit protected inputsand outputs. The simultaneity monitoring of inputs andthe functions “monitored” or “automatic start” can beset as an option. The operation in two-hand control toEN 574 type IIIC in combination with electronic sensorsor mechanical switches is another advantage of thesafety relay.
product news
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
E-stop with cross-fault monitoring andoptional simultaneity monitoring.
Connection of mechanical safety switchesand fail-safe sensors.
For clocked fail-safe sensors fromifm electronic.
Two-hand control to EN 574, type IIIC,mechanical or electronic.
Certified to IEC 61508, ISO 13849-1,EN 574 type IIIC.
Safety relay for the protectionof operators and machinery.
23
11.2009
Technical data (extract)
Operating voltage [V] 24 DC (19.2...30 DC)
Short-circuit protection on input side •
Reverse polarity protection on input side •
Protection IP 20
Ambient temperature [°C] -25...55
Output current per safesemiconductor output (13, 14) 100 mA
Status indication LED1 x green1 x red
4 x yellow
Electrical design:Output function
2 safe short-circuit proofsemiconductor outputs
(positive switching)
Certified toSIL 3 (IEC 61508), ISO 13849-1
two-hand control type IIIC (EN 574)
Safety relay with semiconductor outputs for mechanical switches or electronic sensors,e.g. for light barriers, light curtains, fail-safe sensors or two-hand control.
Dimensions
25 105
35,5
100
LED
Type
[mm]
Housing material Enable current path Signal current path Feedback contacts Orderno.
100 x 25 x 105 PA G1503S2 x semiconductor 1 x PNP 1
You can find further information in the operating instructions.
G1503S
Fail-safe inductive sensors
Type Description Orderno.
GF711SEnable zone:0.5...4 mm, nf
GF711S
1) terminal strip for screw terminals
GM701SEnable zone:10...15 mm,
f / nf
GM705SEnable zone:4...20 mm,
f / nf
GM701S
Rectangular housing 40 x 40 mm
Threaded housing M12 x 1
GG711S
Threaded housing M18 x 1
GG711SEnable zone:1...8 mm, nf
GG712SEnable zone:1...5 mm, f
GI701S
Threaded housing M30 x 1.5
GI701SEnable zone:6...12 mm, nf
GI711SEnable zone:1...15 mm, nf
GI712SEnable zone:1...10 mm, f
Type Description Orderno.
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
Safety technology
For further technical data please go to: www.ifm.com
24
Unit with terminal chamberto complement the existingproduct range.
Unit with terminal chamberTwo captive screws above the cable gland enable an easyopening and closing of the terminal chamber.The wiring can be maintained if the sensor is replaced,thanks to the removable terminal block. As an option, asolenoid valve can be triggered.
Position indicationThe position of the actuator can be clearly seen fromalmost all angles due to the slightly raised position LED.
AccessoriesSoft rubber plugs are available to close the oblong holes.They prevent clogging of the screw heads and at the sametime result in a closed housing surface.
product news
Easy access and removable terminal strip.
Suitable for armoured cable.
Clearly visible position indicators.
Robust housing.
Lasered type label: permanently legible.
Valve position in a new light.
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
25
11.2009
Short-circuit protection •
Reverse polarity / overload protection • / •
Housing material PA
33
92
6,3
18,8
60
7,5
5,5
3060
Dimensions
Connection Current rating
[mA]
Ub
[V]
Protection Orderno.
3-wire · Output function no
terminal chamber 10010...30 DC IP 65, IP67 / II IN5409
Output stage
PNP
Ambienttemperature
[°C]
-25...80
Type Description Orderno.
Switching cam, Ø 53 mm, PA 6 E17320
Switching cam, Ø 65 mm, PA 6 E17327
Switching cam, Ø 102 mm, PA 6 E17328
Plugs for covering the oblong holes E12212
Screw plugs standard E12209
For a detailed selection tool sorted by actuatormanufacturers please go to:http://www.ifm.com/ifmgb/web/puck_sel.htm
Common technical data
Switching frequency [Hz] 500
Sensing range [mm] 4 nf
M20 x 1.5 fitting standard E12208
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
Valve sensors
For further technical data please go to: www.ifm.com
Accessories(to be ordered separately)
1) sensor 12) sensor 23) LED 4) LED
26
Powerful photoelectricsensors in a small design.
ApplicationsWhenever there is little space for sensors or when smallparts are to be detected, the small photoelectric sensorsof the O7 series are the ideal problem solvers. Typicalapplications are feeding and handling technology.
AdvantagesThe small light spot and the narrow light cone enable thedetection of small objects even over long distances. Withtheir fixed setting, the sensors are ready for operationimmediately after installation (plug & play). Diffuse reflec-tion sensors with background suppression with 30, 50 or100 mm range are available. Visible red light allows fastand simple alignment.
product news
Ideal for position detection in feedingand handling.
Through-beam, retro-reflective and diffusereflection sensors with fixed setting.
Visible red light for an easy alignment.
Diffuse reflection sensor with precisebackground suppression.
Small light spot for detecting smallobjects.
The youngest of the opto family:O7 – small, compact, precise.
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
27
11.2009
Applications:Handling technology, robotics and automation
Accessories
Type Description Orderno.
Mounting set for clamp mounting,stainless steel E21237
Mounting set for free-standingmounting, stainless steel E21238
Mounting set for free-standing mountingwith fine adjustment, stainless steel E21239
Mounting set with ball joint,galvanised, stainless steel E21240
Mounting rod, 120 mm, Ø 10 mm,M8 thread, stainless steel E21081
Cube for mounting on an aluminiumprofile, M8 thread, diecast zinc E20950
Prismatic reflector 50 x 50 mm,plastics E20744
M8 connector (3 poles) with 200 mm PUR cable · 3-wire DC PNP
TypeO7
Range
[mm]
Switchingfrequency
[Hz]
Currentconsumption
[mA]
Orderno.
1...30 750 20 O7H200
1...30 O7H201
0...50
750
750
20
20 O7H202
0...50 750 20 O7H203
0...100 750 20 O7H204
0...100
Light spotdiameter
[mm]
3
3
4.5
4.5
5
5
Light-on / dark-onmode
• / –
– / •
• / –
– / •
• / –
– / •750 20 O7H205
Operating voltage [V] 10...30 DC
Type of light red light 632 nm
Short-circuit protection, pulsed •
Current rating [mA] 100
Voltage drop [V] < 2,5
Reverse polarity / overload protection • / •
Ambient temperature [°C] -25...60
Function displaySwitching status LED yellow
Materials housinglens
cable
PAPMMA
PUR
Protection IP 65, III
Common technical data
System
Diffuse reflection sensor withbackground suppression
Diffuse reflection sensor withbackground suppression
Diffuse reflection sensor withbackground suppression
0...1000 1000 20 O7P200
0...1000
55
55
– / •
• / –1000 20 O7P201Retro-reflective sensor with
polarisation filter
0...1500 1000 10 O7E200
0...1500
–
–
– / •
• / –1000 10 O7E201Through-beam – receiver
0...1500 – 20 O7S20060 –Through-beam – transmitter
9
15
26 20,3
7,6
6,5
M3
LED 9
Example O7P200
Dimensions
For further technical data please go to: www.ifm.com
Photoelectric sensors
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
28
Slim design with ranges up to20 m and finger protection.
Type 2 and type 4 safety light curtainsto IEC 61496.
Now with SIL to IEC 61508 andPL to ISO 13849.
Finger protection with 6 m range.
Can be installed in L shape withoutdead band.
Easy to connect via the tried and testedM12 connector (5 or 8-pin).
Safe and certifiedThe safety light curtains and light grids have been devel-oped in accordance with the current standards and certi-fied by TÜV Süd. They meet the requirements type 2 / SIL2or type 4 / SIL3, helping you to stay on the safe side – nomatter what areas you want to protect.
VersionsVersatile versions in a slim design are available for appli-cations from finger protection to body protection. Rangesup to 12 or 20 m in resolutions (detection capacity) of 14,20, 30, 40, 50 and 90 mm. The light grids are availablein 2, 3 or 4-beam version.The protected area height is selectable from 160 mm to1510 mm in distances of 150 mm.They all have one thing in common: the very small housingdimensions of only 28 x 30 mm.
product news
Light frame, long reach.ifm light curtains:
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
29
Applications: access limitations and primary guarding, robot cells, pick-and-place machines,production lines in industrial automation.
Safety light curtains
Common technical data
Operating voltage [V] 19.2...28.8
Safety outputs (OSSDs) 2 x PNP
Current rating [mA] 2 x 400
Current consumption [mA]Transmitter
Receiver4283
Ambient temperature [°C] -10...55
Protection IP 65, IP 67
Dimensions (W x D) [mm] 28 x 30
Connectionmax. cable length [m]
M12 connector100
Safety categoryIEC 61496-1: 2004IEC 61496-2: 2006
IEC 61508: 1998ISO 13849-1: 2006
type 2 / type 4
SIL 2 / SIL 3PL d / PL e
Photoelectric sensors
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
OY040SOY039SOY038SOY037SOY036SOY035SOY034SOY033SOY032SOY031S
OY060SOY059SOY058SOY057SOY056SOY055SOY054SOY053SOY052SOY051S
OY080SOY079SOY078SOY077SOY076SOY075SOY074SOY073SOY072S
OY100SOY099SOY098SOY097SOY096SOY095SOY094S
30
40
50
90
Protected area width 0...4 m / 3...12 mType 2 / SIL2 / PLd
OY050SOY049SOY048SOY047SOY046SOY045SOY044SOY043SOY042SOY041S
OY070SOY069SOY068SOY067SOY066SOY065SOY064SOY063SOY062SOY061S
30
40
50
90
Protected area width 0...4 m / 3...12 mType 4 / SIL3 / PLe
Protected area width 0...4 m / 3...12 m
2 beamsin a distanceof 500 mm
3 beamsin a distanceof 400 mm
4 beamsin a distanceof 300 mm
Safety light grid
OY090SOY089SOY088SOY087SOY086SOY085SOY084SOY083SOY082S
OY110SOY109SOY108SOY107SOY106SOY105SOY104S
OY010SOY009SOY008SOY007SOY006SOY005SOY004SOY003SOY002SOY001S14
Protected area width 0...3 m / 1...6 m
1510136012101060910760610460310160
Protected area height[mm]
Type 4 / SIL3 / PLe
Resolution /detection capacity
[mm]
OY230SOY229SOY228SOY227SOY226SOY225SOY224SOY223SOY222SOY221S
OY250SOY249SOY248SOY247SOY246SOY245SOY244SOY243SOY242SOY241S
OY270SOY269SOY268SOY267SOY266SOY265SOY264SOY263SOY262SOY261S
OY290SOY289SOY288SOY287SOY286SOY285SOY284SOY283SOY282S
20
30
40
50
OY210SOY209SOY208SOY207SOY206SOY205SOY204S90
Protected area width 0...10 m / 3...20 m
Type 2SIL2PLd
OY113SOY112SOY111S
Protected area width 0...4 m / 3...12 m
OY116SOY115SOY114S
Protected area width 0...10 m / 3...20 m
OY122SOY121SOY120S
Type 4SIL3PLe
Type 4 / SIL3 / PLe
30
40 2010
3
1010,528
28
5,5
40
10
2010
1,5
M5
14,5
30
28
T
M12x1
1129
,561
,5L
R
Dimensions
Accessories
Type Description Orderno.
Vibration damper,set with 4 pcs., rubber, galvanised metal EY3001
Vibration damper,set with 6 pcs., rubber, galvanised metal EY3002
Laser adjustment aid for light curtains,visible red light 650 nm EY3099
Corner mirror
Description Orderno.
Corner mirror, length 250 mm,with angle bracket, aluminium, galvanised metal EY1001
Corner mirror, length 400 mm,with angle bracket, aluminium, galvanised metal EY1002
Corner mirror, length 540 mm,with angle bracket, aluminium, galvanised metal EY1003
Corner mirror, length 715 mm,with angle bracket, aluminium, galvanised metal EY1004
Corner mirror, length 885 mm,with angle bracket, aluminium, galvanised metal EY1005
Corner mirror, length 1060 mm,with angle bracket, aluminium, galvanised metal EY1006
Corner mirror, length 1230 mm,with angle bracket, aluminium, galvanised metal EY1007
Corner mirror, length 1400 mm,with angle bracket, aluminium, galvanised metal EY1008
Corner mirror, length 1450 mm,with angle bracket, aluminium, galvanised metal EY1009
Corner mirror, length 1600 mm,with angle bracket, aluminium, galvanised metal EY1010
T: transmitter, R: receiver1) LED 3-colour, 2) LED, 3) LED 2-colour
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
Easy installationThe units have a T-slot on the back for very easy installa-tion. Angle brackets are enclosed with all units. The resolution is ensured also for installation in L or Tshape. Given the short distance from the first light beam,the units can be installed without dead band on one side.
Easy wiringThe units are configured via the pin connection of the 5-or 8-pin M12 connector. To do so, you need no PC or soft-ware. Functions such as EDM (External Device Monitoring),restart or external muting (safety relay G2001S) can beimplemented.
Adjustable bracket axial ± 7°,set with 4 pcs., galvanised metal EY3004
Adjustable bracket axial ± 7°,set with 6 pcs., galvanised metal EY3005
Test probe for resolution, Ø 14 mm EY3006
Test probe for resolution, Ø 20 mm EY3007
Test probe for resolution, Ø 30 mm EY3008
Test probe for resolution, Ø 40 mm EY3009
Test probe for resolution, Ø 50 mm EY3010
Corner mirror with base
Type Description Orderno.
Corner mirror with base for2-beam light grids / light curtains EY1011
Corner mirror with base for3-beam light grids / light curtains EY1012
Corner mirror with base for4-beam light grids / light curtains EY1013
Corner mirror with base for light curtain> 1360 mm EY1014
Mounting base EY2005
31
11.2009
Connectors and splitter boxes
Type Description Orderno.
Socket, M12, 5 m, 8-pin, PUR
Socket, M12, 10 m, 8-pin, PUR
Socket, M12, 5 m, 8-pin, PUR
Socket, M12, 10 m, 8-pin, PUR
Socket, M12, 2 m, 5-pin, PUR
Socket, M12, 5 m, 5-pin, PUR
Socket, M12, 10 m, 5-pin, PUR
Socket, M12, 2 m, 5-pin, PUR
Socket, M12, 5 m, 5-pin, PUR
Socket, M12, 10 m, 5-pin, PUR
Evaluation unit
Type Description Orderno.
G1501S
Safety relay,multifunctional,
2relay outputs
G2001S
Safety relay,2
relay outputs,muting function
AS-i bus system
Type Description Orderno.
AC007S
Safe AS-iinput module,2 OSSD inputs
viaM12 connector
AC5003Flat cable
lower part,yellow/black
For further technical data please go to: www.ifm.com
Photoelectric sensors
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
G1503SSafety relay
Semiconductoroutputs
E12166
E12167
E12168
E12169
EVC070
EVC071
EVC072
EVC073
EVC074
EVC075
Adapter cables
Type Description Orderno.
Adapter cable for receiver light curtainAUTOMATIC start EY3090
Adapter cable for transmitter light curtainLONG RANGE > 3 m EY3091
Adapter cable for receiver light curtainSHORT RANGE < 4 m EY3092
AC031S
1-channel,enhanced, withintegrated safe
slave
AC032S
2-channel,enhanced, withintegrated safe
slave
AS-i safety monitor
SmartLine module
AC030SSafe SmartLineoutput module4 DI / 1 SO R
32
Robust optical forkand angle sensors with a highswitching frequency.
Quick set-up:no need to align transmitter and receiver.
Easy sensitivity setting via potentiometer.
Light-on/dark-on mode via rotary switch.
Across the whole fork width:fine and precise light beam!
Metal housing reduces distortion.
Optical sensors in new designsThe new ifm units with robust metal housing resist distor-tion compared to conventional plastic forks. Comparedto through-beam sensors, their advantage is that thetime-consuming alignment of transmitter and receiver isnot necessary.These optical sensors are used in particular for part moni-toring in feeder and handling systems. Further applica-tion examples are belt edge or double feed monitoringwith the exact sensitivity setting via potentiometer beingvery helpful. The fine light beam with its constant smalldiameter is also ideal for monitoring shaft imbalance.
from all angles.Easy, quick and precise
product news
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
33
04.2009
Optical fork sensor type OPU · M8 connector · 3-pole · infrared · PNP/NPN
TypesOPU / OPL
Fork depth(d)
[mm]
Smallest detectableobject
Ø [mm]
Switching frequency
[Hz]
Orderno.
17 OPU200
Fork width(w)
[mm]
10 0.3 10000
Operating voltage [V DC] 10...35
Short-circuit protection, pulsed •
Current rating [mA] 200
Ambient temperature [°C] -25...60
Reverse polarity / overload protection • / •
Housing materials Diecast zinc
Common technical data
Protection IP 67, III
OutputL = light-on modeD = dark-on mode
L / D, selectable
Optical fork sensor type OPU · M8 connector · 3-pole · red light · PNP
25 OPU20120 0.4 4000 L / D, selectable
35 OPU20230 0.5 4000 L / D, selectable
55 OPU20350 0.5 4000 L / D, selectable
55 OPU20480 0.5 4000 L / D, selectable
60 OPU205120 0.8 2000 L / D, selectable
Optical fork sensor type OPU · M8 connector · 3-pole · red light · NPN
25 OPU20720 0.4 4000 L / D, selectable
35 OPU20830 0.5 4000 L / D, selectable
55 OPU20950 0.5 4000 L / D, selectable
55 OPU21080 0.5 4000 L / D, selectable
60 OPU211120 0.8 2000 L / D, selectable
Optical angle sensor type OPL · M8 connector · 3-pole · PNP
Sensor width(z)
[mm]
Smallest detectableobject
Ø [mm]
Switching frequency
[Hz]
Orderno.
60 OPL200
Side lengths(x, y)[mm]
50 0.5 4000
OutputL = light-on modeD = dark-on mode
L / D, selectable
100 OPL20180 0.7 4000 L / D, selectable
Optical angle sensor type OPL · M8 connector · 3-pole · NPN
60 OPL20250 0.5 4000 L / D, selectable
100 OPL20380 0.7 4000 L / D, selectable
Dimensions
Connectors and splitter boxes
Type Description Orderno.
Socket, M8, 3-pole,2 m black, PUR cable E11486
Socket, M8, 3-pole,5 m black, PUR cable E11487
Socket, M8, 3-pole,2 m black, PUR cable E11489
Socket, M8, 3-pole,5 m black, PUR cable E11490
For further technical data please go to: www.ifm.com
Photoelectric sensors
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
1220
30
10
M8x
1
10
LED
4,34,5
4,5
4,5
12,5
1010
W=
50
5
D = 5580
Example OPU203
7510
Z60
Y=
5075
22,5
4,3
4,5
4,5
4250
X=50
M8x
14250
10,5LED
17,5 25
,5 35,5
10
Example OPL200
1) Potentiometer sensitivity2) Output function switch
34
Compact and powerful M18photoelectric sensors.
The low-cost alternativein PNP or NPN design.
Through-beam and retro-reflectivesensors with fixed setting (plug & play).
Diffuse reflection sensor:easy setting via potentiometer.
Universal mounting using systemcomponents and mounting accessories.
For standard applications in conveyingand materials handling.
ApplicationsThe OG type plastic sensors are especially designed forposition detection in conveying and materials handling.These sensors are designed to meet the technical require-ments of the market at an affordable price.
Cost savingSetting of the through-beam sensors and retro-reflectivesensors with polarisation filter is fixed. This means cost-saving rapid up-time after quick installation with theoptional accessories. The diffuse sensor has a potentio-meter for fine-tuning in the application.
now also in plastic.The OG BasicLine
product news
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
35
11.2009
Applications:conveying and materials handling
Diffuse reflection sensor · red light 645 nm · M12 connector · 3-wire
TypeOGT, OGP, OGS, OGE
Protection Switchingfrequency
[Hz]
Currentconsumption
[mA]
Orderno.
IP 65, III OGT100
Range
[mm]
10...400 1000 20
IP 67, III OGS100
IP 67, III
8000
8000
–
1000
20
8 OGE100
Current rating [mA] 200
Operating voltage [V DC] 10...30
Short-circuit protection, pulsed •
Ambient temperature [°C] -25...60
Voltage drop [V] < 2.5
Reverse polarity / overload protection • / •
Function display LEDOutput status yellow
Accessories
Type Description Orderno.
Clamp, for mounting rod Ø 12 mm,diecast zinc, steel E20720
Clamp, for mounting rod Ø 12 mm,diecast zinc, steel E20721
Cylinder bolt, M10 x 45 mm,galvanised steel E21208
Cube for mounting on an aluminiumprofile, M10 thread, diecast zinc E20951
Common technical data
Materials
Accessories(supplied with the device)
ABS, PMMA
2 plastic nuts
Connection M12 connector
IP 67, III50...2500 1000 20 OGP100
Light-on /dark-onmode
• / –
–
– / •
– / •
240°potentiometer
•
IP 65, III OGT10110...400 1000 20 – / • •
–
–
IP 67, III8000 1000 8 OGE101• / – –
–
IP 67, III50...2500 1000 20 OGP101• / – –
Retro-reflective sensor · red light 645 nm · M12 connector · 3-wire
Through-beam sensor – transmitter · red light 645 nm · M12 connector
Through-beam sensor – receiver · red light 645 nm · M12 connector · 3-wire
Connectors and splitter boxes
Type Description Orderno.
Socket, M12,2 m black, PUR cable EVC001
Socket, M12,5 m black, PUR cable EVC002
Socket, M12,2 m black, PUR cable EVC004
Socket, M12,5 m black, PUR cable EVC005
Angle bracket for type M18,stainless steel E10736
Mounting rod, 100 mm, Ø 12 mm,M10 thread, stainless steel E20938
Mounting rod, 200 mm, Ø 12 mm,M10 thread, stainless steel E20940
For further technical data please go to: www.ifm.com
Photoelectric sensors
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
IP 65, III OGT10210...400 1000 20
IP 67, III8000 1000 8 OGE102
IP 67, III50...2500 1000 20 OGP102
• / –
– / •
– / •
•
IP 65, III OGT10310...400 1000 20 – / • •
–
IP 67, III8000 1000 8 OGE103• / – –
–
IP 67, III50...2500 1000 20 OGP103• / – –
Electricaldesign
DC PNP
–
DC PNP
DC PNP
DC PNP
DC PNP
DC PNP
DC NPN
DC NPN
DC NPN
DC NPN
DC NPN
DC NPN
36
Photoelectric M18 sensorsoptimised for harshapplications in wet areas.
Selected materials, suited forfood applications.
Consistent use of ifm’s applicationknow-how.
Ideal sealing conceptIP 67, IP 68 and IP 69K.
Fixed ranges – simple set-up(plug & play).
Tested quality, confirmed byECOLAB certificate.
Applications for OG wetlineThe OG wetline series was specially developed for appli-cations in the food industry, such as in cheese plants,breweries or in the meat industry. The development wasable to benefit from ifm’s extensive application know-howand experience.
Robust stainless steel housing with cableThe stainless steel housing, plastic lens, food-grade seal-ing material as well as a 6 m long PVC cable qualify theOG wetline for wet areas in the food industry, in whichaggressive cleaning agents are used.
Fixed rangesThe OG wetline has fixed ranges. For the versions withbackground suppression there is a choice of 100 mm,200 mm or 300 mm range.
OG wetline with cable.
product news
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
37
04.2009
Applications:Hygienic and wet areas
6 m PVC cable · 3-wire DC PNP
TypeOG wetline
Range
[m]
Switchingfrequency
[Hz]
Currentconsumption
[mA]
Orderno.
0.1 1000 25
0.1
0.2
1000
1000
25
25
0.2 1000 25
0.3 1000 25
0.3
Light spotdiameter
[mm]
8
8
12
12
15
15
Light-on / dark-onmode
• / –
– / •
• / –
– / •
• / –
– / • 1000 25
Operating voltage [V] 10...36 DC
Type of light red light 624 nm
Short-circuit protection, pulsed •
Current rating [mA] 200*
Voltage drop [V] < 2.5
Reverse polarity / overload protection • / •
Ambient temperature [°C] -25...80
Function displaySwitching status LED yellow
Materials HousingLens
Sealing
high-grade stainless steelPMMAEPDM
Protection IP 67 / IP 68 / IP 69K, II
Accessories
Type Description Orderno.
Mounting set M18, long bracket withclamp Ø 12 mm, stainless steel E21207
Cylinder bolt, M10 x 45 mm,stainless steel E21209
Mounting set M18, short bracket withclamp Ø 12 mm, stainless steel E21206
Angle bracket for type M18,stainless steel E10736
Common technical data
System
Diffuse reflection sensor withbackground suppression
Diffuse reflection sensor withbackground suppression
Diffuse reflection sensor withbackground suppression
0.03...4 1000 15
0.03...4
160
160
– / •
• / – 1000 15Retro-reflective sensor with
polarisation filter
20 1000 10
20
–
–
– / •
• / – 1000 10Through-beam – receiver
20 – 15800 –Through-beam – transmitter
4459
80,461
LED 4 x 90°
5
M18
x1
424
Example OGH306
Mounting rod, 100 mm, Ø 12 mm,M10 thread, stainless steel E20938
Mounting rod, 200 mm, Ø 12 mm,M10 thread, stainless steel E20940
Dimensions
For further technical data please go to: www.ifm.com
Photoelectric sensors
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
*up to 60 °C, followed by a constant linear decreaseto 150 mA at 80 °C
Wiring diagram
BN
BK
BU
L+
L
L+
L
BN
BU
Transmitter
OGH306
OGH307
OGH308
OGH309
OGH310
OGH311
OGP302
OGP303
OGE302
OGE303
OGS301
38
For ATEX 3D areasaccording to the lateststandards.
Tried-and-tested photoelectric sensorsnow for hazardous areas.
Long ranges.
Highest precisionwith background suppression.
Quick setting by means of thenew teach method.
Universal mounting using systemcomponents and mounting accessories.
Applications in hazardous dust areasThese units comply with category 3D for use in zone 22hazardous areas with non-conductive dusts.
VersionsNew sensors for hazardous dust areas complement thesuccessful O5 opto family of ifm electronic. The newversions are based on the established O5 PerformanceLine diffuse reflection sensors with background sup-pression, retro-reflective sensors with polarisation filterand the through-beam system.
Mounting accessoriesThe ATEX sensor is compatible with the tried-and-testedmounting accessories and system components of theO5 series.
product news
hazardous dust areas.The new O5 for
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
39
04.2009
For further technical data please go to: www.ifm.com
Applications:position detection in packaging and conveying
Diffuse reflection sensor · red light 624 nm · M12 connector · background suppression · PNP · wiring diagram no. 1
Common technical data
Range
[mm]
Teach button Switchingfrequency
[Hz]
Protection Currentconsumption
[mA]
Orderno.
50...1800 • O5H51A1000 IP 65, III 25
Retro-reflective sensor · red light 624 nm · M12 connector · polarisation filter · PNP · wiring diagram no. 1
75...10000 • O5P51A2000 IP 65, III 20
Through-beam sensor · red light 624 nm · M12 connector · transmitter · PNP · wiring diagram no. 2
0...25000 – O5S51A– IP 65, III 20
Through-beam sensor · red light 624 nm · M12 connector · receiver · PNP · wiring diagram no. 1
0...25000 • O5E51A1000 IP 65, III 11
Light-on /dark-onmode
programmable
programmable
–
programmable
Operating voltage [V] 10...30 DC
Short-circuit protection, pulsed •
Current rating [mA] 100
Voltage drop [V] < 2.5
Reverse polarity /overload protection • / •
Ambient temperature [°C] -10...50
EMC DIN EN 60947-5-2
MaterialHousing / plug adapter
Front pane / LED windowBezel / protective bracket
PAPMMA
stainless steel
Connectors and splitter boxes
Type Description Orderno.
Socket, M12, 4-pole,2 m black, PUR cable EVC04A
Socket, M12, 4-pole,5 m black, PUR cable EVC05A
Socket, M12, 4-pole,10 m black, PUR cable EVC06A
Wiring diagrams of the units
L+
L
1
4
3
wiring diagram no. 1
1
3
L+
L
wiring diagram no. 2
System components
Type Description Orderno.
Prismatic reflector 50 x 50 mm E20744
Prismatic reflector 95 x 95 mm E20454
Prismatic reflector Ø 42 mm E20004
Prismatic reflector Ø 80 mm E20005
Approval
Photoelectric sensors
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
Clamp with M10 x 55 mm screw E20716
Clamp with M10 x 55 mm screw,stainless steel E20946
Cube for mounting on an aluminiumprofile, M10 thread, diecast zinc E20951
II 3D Ex tD A22 IP 65 T105 °C X
40
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
Photoelectric sensors withexcellent performance nowalso with cable.
The new standard for packagingand conveying.
Extremely long ranges.
Highest precisionwith background suppression.
Easy setting:The new Teach mode.
Universal mounting with systemcomponents and mounting accessories.
All-round photocellWith state-of-the-art technology as well as outstandingperformance and an excellent price /performance ratiothis range is perfect for universal use. Easy installation isensured by a clever mounting concept, with special fix-tures as well as an adapter plate. The 2 m PUR cable canbe cut to any length and thus allows quick and easyconnection to your controller.
Easy adjustmentThe innovative teach method means complex program-ming is no longer required. The unit features one buttoneach for teaching of a precise on and off state for thesensor signal.
The O5 family is growing.
product news
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
41
04.2009
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
Photoelectric sensors
Applications:Position detection in packaging and conveying
System components
Type Description Orderno.
Mounting bracket for rod, complete setincl. clamp, stainless steel E21212
Mounting bracket for rod, complete setincl. clamp, diecast zinc E21211
Protective bracket for rod, complete setincl. clamp, stainless steel E21142
Protective bracket for rod, complete setincl. clamp, diecast zinc E21210
Adapter plate for type OT and O5,stainless steel E21085
Angle bracket for free-standingmounting, stainless steel E21087
Fixing element dovetail,aluminium E21088
Common technical data
10...36 DC
•
200
< 2.5
• / •
-25...60
DIN EN 60947-5-2
PAPMMA
stainless steelTPU
Operating voltage [V]
18.5 x 70.3 x 46.8Dimensions (W x H x D) [mm]
Short-circuit protection, pulsed
Current rating [mA]
Voltage drop [V]
Reverse polarity / overload protection
Ambient temperature [°C]
IP 67, IIProtection
EMC
Material: HousingFront lens / LED window
Front frameOperator interface
For further technical data please go to: www.ifm-electronic.com
O5 fixing element with OC hole centres,aluminium E21114
Diffuse reflection sensor · red light 624 nm · 2 m PUR connection cable · background suppression · 3-wire DC PNP
Ranges
[mm]
Pushbutton Switchingfrequency
[Hz]
Spot Ø atmax. range
[mm]
Currentconsumption
[mA]
Orderno.
50...1800 • O5H5031000 50 25
Retro-reflective sensor · red light 624 nm · 2 m PUR connection cable · polarisation filter · 3-wire DC PNP
75...10000 • O5P5012000 250 20
Through-beam sensor · red light 624 nm · 2 m PUR connection cable · transmitter
0...25000 – O5S501– 625 20
Through-beam sensor · red light 624 nm · 2 m PUR connection cable · receiver · 3-wire DC PNP
0...25000 • O5E5011000 – 11
Light-on / dark-onmode
programmable
programmable
programmable
programmable
Example O5H503
Dimensions
Cylinder bolt, M10 x 120 mm,galvanised steel E21213
Cylinder bolt, M10 x 120 mm,stainless steel E21214
Rod, 200 mm, Ø 12 mm,M10 thread, stainless steel E20940
Prismatic reflector Ø 80 mm,plastic E20005
56
6,446,8
25
5
1
LED
6
2
5x9
25 2
6
1
LED
30,5
24,3
15,4
18,2
19,5
37
5
1) Programming buttons2) When a M5 mounting screw is used,
the max. tightening torque is 2 Nm
42
Photoelectric sensors withlong ranges now alsowith cable connection.
Background suppressed, through-beamand polarised sensors.
Easy and convenient settingvia pushbuttons.
Quality at an attractive price.
Universal mounting.
Wide selection of mounting accessoriesfor time-saving fixing.
Different industriesThis all-round photoelectric sensor with its long range isthe best choice for use in the wood, paper and automo-tive industries, transport and conveying as well as in steelprocessing.
PerformanceLine with cable connectionThe sensitivity is set easily via pushbuttons. The 2 m PURcable can be shortened to any length and thus allowsquick and easy connection to your controller.
Mounting accessoriesThe optional stainless steel bracket gives the best protec-tion. The wide selection of mounting accessories enablessimple, flexible and time-saving installation.
product news
Type O4: pre-cabled.
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
43
04.2009
Applications:wood, paper and automotive industries, transport and conveying, steel processing
System components
Type Description Orderno.
Angle bracket with hole centres, OA, OL,OS, WT, RK, E3JK, XUX (stainless steel)
Mounting brackets for rods,complete set incl. clamp, stainless steel
Mounting bracket for rod,complete set incl. clamp, diecast zinc
Protective bracket for rod,complete set incl. clamp, stainless steel
Protective bracket for rod,complete set incl. clamp, diecast zinc
Angle bracket forfree-standing mounting, stainless steel
Common technical data
Operating voltage [V] 10...36 DC
Short-circuit protection, pulsed •
Current rating [mA] 200
Voltage drop [V] < 2.5
Reverse polarity / overload protection • / •
Ambient temperature [°C] -25...60
Material housingoperator interface
bezel / protective bracket
PATP
stainless steel
Cylinder bolt, M10 x 120 mm,galvanised steel
Cylinder bolt, M10 x 120 mm,stainless steel
Rod, 200 mm, Ø 12 mm,M10 thread, stainless steel
Prismatic reflector Ø 80 mmplastic
Wall mounting (dove tail)with OL hole centres, aluminium
Photoelectric sensors
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
For further technical data please go to: www.ifm-electronic.com
Diffuse reflection sensor · red light 624 nm · 2 m PUR connection cable · background suppression · 3-wire DC PNP
Range
[mm]
Spot Ø atmax. range
[mm]
Protection Switchingfrequency
[Hz]
Currentconsumption
[mA]
Orderno.
Retro-reflective sensor · red light 624 nm · 2 m PUR connection cable · polarisation filter · 3-wire DC PNP
Through-beam sensor · red light 624 nm · 2 m PUR connection cable · transmitter · 3-wire DC PNP
Through-beam sensor · red light 624 nm · 2 m PUR connection cable · receiver · 3-wire DC PNP
Light-on /dark-on mode
Pushbutton
100...2600 50 (for range = 1 m) O4H501IP 67, II 1000 25 programmable•
0...22000 660 O4P501IP 67, II 2000 20 programmable•
0...80000 2400 O4S501IP 67, II – 20 – / ––
0...80000 – O4E501IP 67, II 1000 12 programmable•
Example O4H501
Dimensions
E21117
E21218
E21217
E21216
E21215
E21120
E21122
E21213
E21214
E20940
E20005
27
25,3
19,7
5
29,5 44
,538
,3
2
LED
7,963,8
LED
40
5
8,5
74,4
1
8,5
405x10
1
1) When a M5 mounting screw is used,the max. tightening torque is 2 Nm
2) Programming buttons
44
product news
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
New generationof the well-known OBFfibre-optic amplifiers.
High performance such as a highswitching frequency of 3000 Hz.
LED display to check operation,switching status and function.
Variable mounting options:DIN rail or free-standing mounting.
Easy parameter setting via pushbuttons.
Wide range of fibre optics andaccessories.
New generationThe new generation of fibre-optic amplifiers of type OBFhave an unbeatable price / performance ratio.
Variable installationThe sensors can be mounted on a DIN rail or using fixingholes. The simple ifm teach concept guarantees fast set-up. The sensor is ready for operation by pressing theprogramming buttons twice.
For demanding applicationsFor demanding applications extended functions such asmanual fine adjustment as well as pulse stretching (timedelay function) are available.
at a favourable price!High performance
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
45
04.2009
Photoelectric sensors
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
For further technical data please go to: www.ifm-electronic.com
Applications:Packaging and food industry
M12 connection · 4-pin · electrical design DC
TypeOBF
Numberof inputchannels
OutputL=light-on modeD=dark-on mode
AutomaticrecognitionPNP / NPN
Orderno.
1 OBF500L/D, programmable •
Forfibre optics
FE/FT-11
Range through-beam sensor
[mm]
1200
Range diffusereflection sensor
[mm]
100
Operating voltage [V] 10...30 DC
Type of light red light 630 nm
Voltage drop [V]Switching outputFunction check output
< 2.5< 2.5
Short-circuit protection, pulsed •
Reverse polarity / overload protection • / •
Ambient temperature [°C] -25...60
Current rating [mA]Switching outputFunction check output
10010
Protection IP 65, II
Switching frequency [Hz] 3000
Timer function [s] 0.001...0.09
Materials housing modified PPE
Connectors and splitter boxes
Type Description Orderno.
M12 socket,2 m black, PUR cable EVC001
M12 socket,5 m black, PUR cable EVC002
M12 socket,2 m black, PUR cable EVC004
M12 socket,5 m black, PUR cable EVC005
Acrylic fibre optic, through-beam system
Type DescriptionThrough-beam sensor
Orderno.
range 50 mm,sensing head aluminium E21103
range 150 mm,sensing head aluminium E20615
Further technical data
Type
[mm]
74 x 36 x 15
M8 connection · 4-pin · electrical design DC
1 OBF501L/D, programmable •FE/FT-11 1200 10074 x 36 x 15
2 m PVC connection cable · electrical design DC
1 OBF502L/D, programmable •FE/FT-11 1200 10074 x 36 x 15
M8 connection · 3-pin · electrical design DC
1 OBF503L/D, programmable •FE/FT-11 1200 10074 x 36 x 15
range 250 mm,sensing head aluminium E21102
range 1200 mm,sensing head aluminium E20752
range 60 mm, sensing headstainless steel (1.4301 / 304) E20751
range 140 mm, sensing headstainless steel (1.4305 / 303) E20714
M12 socket,2 m orange, PVC cable EVT064
M12 socket,5 m orange, PVC cable EVT001
M12 socket,2 m orange, PVC cable EVT067
M12 socket,5 m orange, PVC cable EVT004
Acrylic fibre optic, diffuse reflection system
Type DescriptionDiffuse reflection sensor
Orderno.
range 10 mm,sensing head aluminium E21106
range 20 mm,sensing head aluminium E20639
range 60 mm,sensing head aluminium E20758
range 70 mm,sensing head aluminium E21105
range 15 mm, sensing headstainless steel (1.4301 / 304) E20748
range 70 mm, sensing headstainless steel (1.4301 / 304) E20749
Accessories
Type Description Orderno.
cutter for acrylic fibres E20600
You can find more accessorieson our homepage
46
Visual assessment ofdistance, level or volume.
Detection of scenes and objects inthree dimensions at a glance.
Operating principle: time-of-flightmeasurement based on pmd technology.
Illumination, time-of-flight measurementand evaluation in one housing.
3,072 distance values per measurementfor detailed assessment of the application.
4...20 mA / 0...10 V analogue or 2 switch-ing outputs for indication of the results.
electronics: sensing in 3D.A quantum leap in opto-
product news
Object detection in three dimensions –efector pmd 3defector pmd 3d is the first industrial 3D sensor that candetect objects in three dimensions at a glance. The time-of-flight measurement in three dimensions enables theassessment of different applications, for example thedetection of volume, distance or level.Special feature: the time-of-flight measurement andevaluation are integrated on one chip. The sensor chiphas 64 x 48 pixels. Each pixel of this chip matrix evalu-ates its distance to the object. This results in 3,072 dis-tance values at the same time. The image of the objecton the chip matrix and the respective distance valuescorrespond to a 3D image.These values enable the detailed assessment of the ob-ject’s or scene’s characteristics up to a range of 6.5 mwith an unambiguous range up to 48 m.
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
47
04.2009
Applications:visual assessment of distance, level or volume.
Connectors and splitter boxes
Type Description Orderno.
Socket, M12,2 m PUR cable, 8-pole E11950
Socket, M12,5 m PUR cable, 8-pole E11807
Socket, M12,10 m PUR cable, 8-pole E11311
Accessories
Type Description Orderno.
Operating software for 3D sensor E3D200
Mounting set for clamp mounting,Ø 14 mm, stainless steel E3D103
Mounting rod, 100 mm, Ø 14 mm,M12 thread, stainless steel E20939
Technical dataO3D200
Angle of aperture 30° x 40°
Sampling rate /switching frequency [Hz] max. 25, adjustable
Type of sensorPhotonICs® PMD,
resolution:64 x 48 pixels
Function display LED 4 x yellow, 4 x green
Result display / dialogue 4-digit10-segment display
Operating voltage [V] 24 DC (± 10 %)
Illumination infrared (850 nm)
Current consumption [mA] < 1000 (max. 2500)
Current rating [mA] 100(per switching output)
HousingMaterial Front lens
LED window
diecast zincpolycarbonatepolycarbonate
Trigger
Switching inputs
external: 24 V PNP acc.to IEC 61131-2 type 2,
internal
max: 2 (configurable),24 V PNP acc.
to IEC 61131-2 type 2
Switching outputsmax: 2
(configurable)24 V PNP
Analogue output (configurable)
scalable
4...20 mA acc. toIEC 61131-2,
max. load 300 Ω0...10 V acc. toIEC 61131-2,
min. load 10 kΩ
Short-circuit protection, pulsed •
Overload protection •
Ambient temperature [°C] -10...50
Storage temperature [°C] -40...85
Protection IP 67, III
Parameter setting interface Ethernet 10 Base-T /100 Base-TX
Type Description Orderno.
Power supplies
DN2011
Switched-modepower supply
24 V DC, primary,output current
2.5 A, regulated
Parameter setting optionsvia PC / notebook or
10-segment display and2 buttons
Mounting rod, 200 mm, Ø 14 mm,stainless steel E21228
Mounting rod, 300 mm, Ø 14 mm,stainless steel E21229
Mounting rod, 500 mm, Ø 14 mm,stainless steel E21232
Object recognition
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
For further technical data please go to: www.ifm.com
Ethernet, gekreuztes Patchkabel,2 m, PUR-Kabel, M12 / RJ45 E11898
Ethernet, cross-over patch cable,10 m, PUR cable, M12 / RJ45 E12204
Ethernet, cross-over patch cable,20 m, PUR cable, M12 / RJ45 E12205
48
Detection of scenes andobjects in three dimensionsat a glance.
Operating principle: time-of-flightmeasurement based on pmd technology.
Illumination, time-of-flight measurementand evaluation in one housing.
Enormous range up to 6.5 m,unambiguous range even up to 48 m.
3,072 distance and grey values for thedetailed assessment of your application.
Integration via a PC parameter settingtool or software connection via SDK.
vation for vision integration.3D camera: a brilliant inno-
product news
pmd 3d cameraThe pmd 3d camera detects scenes and objects at aglance. PMD stands for Photonic Mixer Device and isthe basis of the on-chip time-of-flight measurementmethod. In addition to the lateral dimension, known asthe resolution of a camera chip, this quantum leap inindustrial vision also offers the associated depth informa-tion without the need for a separate second element.Because of the maximum range up to 6.5 m and anunambiguous range of 48 m, these 3,072 distance andgrey values enable a low-cost solution in a variety ofapplications. Applications include among others: packa-ging, storage and materials handling, airport logistics,collision avoidance, robotics, monitoring of space andpersons.The camera is smoothly integrated into its programmingenvironment via a software development kit (SDK).
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
49
04.2009
Applications: packaging, storage and materials handling, airport logistics, collision avoidance,robotics, monitoring of space and persons
Operating software for 3D camera E3D201
Object recognition
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
For further technical data please go to: www.ifm.com
Accessories
Type Description Orderno.
Technical dataO3D201
Angle of aperture 30° x 40°
Sampling rate /switching frequency [Hz] max. 25, adjustable
Type of sensorPhotonICs® PMD,
resolution:64 x 48 pixels
Function display LED 4 x yellow, 4 x green
Result display / dialogue 4-digit10-segment display
Operating voltage [V] 24 DC (± 10 %)
Illumination infrared (850 nm)
Current consumption [mA] < 1000 (max. 2500)
Current rating [mA] 100(per switching output)
HousingMaterial Front lens
LED window
diecast zincpolycarbonatepolycarbonate
Trigger
Switching inputs
external: 24 V PNP acc.to IEC 61131-2 type 2,
internal
max: 2 (configurable),24 V PNP acc.
to IEC 61131-2 type 2
Switching outputsmax: 2
(configurable)24 V PNP
Analogue output (configurable)
scalable
4...20 mA acc. toIEC 61131-2,
max. load 300 Ω0...10 V acc. toIEC 61131-2,
min. load 10 kΩ
Short-circuit protection, pulsed •
Overload protection •
Ambient temperature [°C] -10...50
Storage temperature [°C] -40...85
Protection IP 67, III
Parameter setting interface Ethernet 10 Base-T /100 Base-TX
Parameter setting optionsvia PC / notebook or
10-segment display and2 buttons
Connectors and splitter boxes
Type Description Orderno.
Socket, M12,2 m PUR cable, 8-pole E11950
Socket, M12,5 m PUR cable, 8-pole E11807
Socket, M12,10 m PUR cable, 8-pole E11311
Mounting set for clamp mounting,Ø 14 mm, stainless steel E3D103
Mounting rod, 100 mm, Ø 14 mm,M12 thread, stainless steel E20939
Type Description Orderno.
Power supplies
DN2011
Switched-modepower supply
24 V DC, primary,output current
2.5 A, regulated
Mounting rod, 200 mm, Ø 14 mm,stainless steel E21228
Mounting rod, 300 mm, Ø 14 mm,stainless steel E21229
Mounting rod, 500 mm, Ø 14 mm,stainless steel E21232
Ethernet, gekreuztes Patchkabel,2 m, PUR-Kabel, M12 / RJ45 E11898
Ethernet, cross-over patch cable,10 m, PUR cable, M12 / RJ45 E12204
Ethernet, cross-over patch cable,20 m, PUR cable, M12 / RJ45 E12205
50
Two versions:synchro flange orclamp flange.
Features and benefitsAbsolute encoders provide a clearly coded position valuefor each angular position.This value is also available directly after a power failure.There are two versions of absolute encoders: singleturnand multiturn. The singleturn resolves the mechanicalrevolution of the shaft. The multiturn can resolve up to4,096 revolutions in addition.The integrated setting options for the bus address, baudrate, bus termination and zero reset button enable aneasy set-up of the encoder. With the module or statusLED, easy diagnosis is possible on the encoder.
product news
Industrial standard housing foruniversal use.
Robust design.
Encoder profile DSP 406, class 1 and 2.
Easy pushbutton setup.
Clearly visible diagnostic LEDs.
The new generation ofCANopen encoders.
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
51
11.2009
Encoders
120°
42
20°
24
1
80
18
4
36
50 583
10,5
h7
Dimensions Resolution
Singleturn Multiturn
Orderno.
Singleturn encoder with terminal chamber
13 bit RN7003
Solidshaft
6
Flange
Synchro
13 bit RN700410Clamp
Accessories
Type Description Orderno.
Flexible coupling with clamp connection,Ø 6mm / Ø 6mm, aluminium E60064
Flexible coupling with clamp connection,Ø 6mm / Ø 10mm, aluminium E60066
Angle bracket for synchro flange,aluminium, black anodized E60034
Angle bracket for clamp flange,aluminium, black anodized E60035
Multiturn encoder with terminal chamber
RM70036Synchro 25 bit
25 bit RM700410Clamp
Fastening clamp for synchro flange,steel E60041
Spring disc coupling,Ø 6mm / Ø 6 mm, diecast zinc, PA E60121
Spring disc coupling,Ø 6mm / Ø 10 mm, diecast zinc, PA E60117
Singleturn and multiturn encoders with CANopen interface DS301according to the encoder profile DSP406 Class 1 and 2.
Operating voltage [V DC] 9...36
Current consumption [mA] 250
Accuracy ± 1 LSB
Ambient temperature [°C] -40...70
Protection rating at the shaft entry IP 66 to IEC 60529
Protection rating at the housing IP 67 to IEC 60529
Maximum mechanical [1/min]rotational speed 6000
Maximum mechanical [N]shaft load axial 10
Maximum mechanical [N]shaft load radial 20
Starting torque [Ncm] < 1 at 20°C
Shaft material stainless steel(1.4101/316)
Housing material aluminium
Vibration resistance [g] 10 (55-2000 Hz)to IEC 60068-2-6
Shock resistance [g] 100 (6 ms)to IEC 60068-2-27
Short-circuit and overload protection • / •
Type of code binary
Maximum baud rate 1 Mbit
Baud rate, address adjustable via DIP switchor software
Bus terminating resistor adjustable viaDIP switch
Programmable parameters
CAN parametersScaling
Preset valueBaud rate
Direction of rotationAddress
TypeRN, RM
Common technical data
1) M4 x 5
Synchro flange
120°
48
20°
24
1
70
18
1036 58
20
f8
10
1) M4 x 5
Clamp flange
Posi
tio
n s
enso
rs a
nd
ob
ject
rec
og
nit
ion
For further technical data please go to: www.ifm.com
52
Aseptoflex Vario – new G 1process connectionwith 4 sealing options.
Prepared and tested forprocess fittings of hygienic areas.
Suitable for medium temperaturesup to120 °C.
LED bar graph for indication ofswitch point and flow.
Process adapters available as accessories.
Material (wetted parts)high-grade stainless steel (1.4435 / 316L).
Easy handling and high functionalityAdjustment to the flow and setting of the switch pointsare carried out by pressing a pushbutton. Flow and switchpoint are indicated by multicolour LEDs directly on theunit. The unit offers high repeatability to ensure optimumprocess consistency.The sensor can be individually, in accordance with theapplication, adjusted using the teach function. At thesame time the sensor enables the detection of separationlayers (water / air).Electronic locking of the settings and factory reset of theparameters provide additional safety.
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms Compact flow monitoring
in hygienic areas.
product news
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
53
11.2009
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
Flow sensors
Setting rangeliquid / gaseous
[cm/s]
Greatest sensitivityliquid / gaseous
[cm/s]
Medium temperature
[°C]
Max.T0 gradient
[K/min]
Probe length
[mm]
Orderno.
M12 connector · output functions NC / NO
3...300 / 200...3000 3...100 / 200...800 -25...95 (120 max. 1 h) 150 20 SI6600
3...300 / 200...3000 3...100 / 200...800 -25...95 (120 max. 1 h) 300 38 SI6700
3...300 / 200...3000 3...100 / 200...800 -25...95 (120 max. 1 h) 300 55 SI6800
Further technical data
Operating voltage [V] 19...36 DC
Short-circuit protection, pulsed •
Housing materials
high-grade stainless steel(1.4435 / 316L),PC (Makrolon),
PBT-GF 20,EPDM/X (Santoprene);
O-ring: FKM
Materials(wetted parts)
high-grade stainless steel(1.4404 / 316L),
surfacecharacteristics: Ra < 0.4 / Rz 4
Protection IP 67 / IP 69K, III
Ambient temperature [°C] -25...60
Pressure resistance [bar] 30
Reverse polarity / overload protection • / •
TypeSI6600, SI6700, SI6800
Connectors and splitter boxes
Type Description Orderno.
Socket, M12, 4-pole,5 m orange, PVC cable EVT001
Socket, M12, 4-pole,10 m orange, PVC cable EVT002
Socket, M12, 4-pole,25 m orange, PVC cable EVT003
Socket, M12, 4-pole,5 m orange, PVC cable EVT004
Socket, M12, 4-pole,10 m orange, PVC cable EVT005
Socket, M12, 4-pole,25 m orange, PVC cable EVT006
Applications:Hygienic areas, viscous media
Current rating [mA] 250
Protective cover, PP colourless E40203
For further technical data please go to: www.ifm.com
Aseptoflex Vario – the new process connectionwith 4 sealing optionsThe new process connection Aseptoflex Vario with G 1thread enables sealing via a metal sealing edge, O-ringsof various materials (e.g. EPDM or FKM), a PEEK ring orcommon sealing materials (e.g. teflon tape). Variousprocess adapters (clamp, DIN11851 pipe fittings, etc.)are available as accessories.In addition, the G 1 thread fits into conventional adaptersand T-pieces. Sealing at the thread via an additional slotwhich can locate an O-ring or flat seal is possible.
Accessories
Type Description Orderno.
Aseptoflex Vario adapter on clamp 1-1.5"with PEEK / elastomeric O-ring E33201
Aseptoflex Vario adapter on clamp 1-1.5"with metal-on-metal sealing E33701
Aseptoflex Vario adapter on clamp 2"with PEEK / elastomeric O-ring E33202
Aseptoflex Vario adapter on clamp 2"with metal-on-metal sealing E33702
Aseptoflex Vario adapter to DIN 11851DN40 (1.5") with PEEK/elastomeric O-ring E33212
Aseptoflex Vario adapter to DIN 11851DN40 (1.5") with metal-on-metal sealing E33712
Aseptoflex Vario welding adapter E30122
FKM (Viton) sealing ringfor Aseptoflex Vario E30123
PEEK sealing ringfor Aseptoflex Vario E30124
54
With flow rate,totalising andtemperature indication.
High accuracy, repeatability andmeasurement dynamics.
Suitable for conductive media from20 μS/cm, flow rate up to 100 l/min.
Also available with EPDM O-ringfor drinking water applications.
Different process connections possibleusing adapters
4-digit alphanumeric LED displayfor representation of the units.
Magnetic-inductive flow sensor in water cycle forquantity monitoring.
Measurement techniqueThe flow sensor is based on Faraday’s principle of induc-tion.The conductive medium flowing through a pipe in a mag-netic field generates a voltage which is proportional tothe flow velocity or flow rate.
Device functionThis voltage is detected via electrodes and converted inthe evaluation electronics.Analogue, binary and pulse outputs offer various possi-bilities to process the measured data. Due to the flexibleprogramming by means of pushbuttons the flow sensorcan be adapted to different conditions. The sensor ismounted via an adapter. A high protection rating and arobust compact housing distinguish the sensor in the field.
MID flow sensor family.Addition to the
product news
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
55
11.2009
Measuring rangeflow
[l/min]
Pulse value Response timeflow[s]
Accuracyflow
Processconnection
Orderno.
M12 connector · DC PNP/NPN · with display · FKM O-rings
0...25 0.05 l...30 000 m3 < 0.150 (dAP = 0) ± (2 % MV + 0.5 % VMR) G 1/2 SM6000
Further technical data
Operating voltage [V] 20...30 DC
Short-circuit protection, pulsed •
Housing materials
high-grade stainless steel(316S12);
PBT-GF 20; PC;EPDM/X (Santoprene)
Sensor materialstainless steel (316S16);
PEEK(polyether-etherketone)
Protection rating, protection class IP 67, III
Output function OUT1SM6000, SM7000, SM8000SM6100, SM7100, SM8100
OUT2
normally open /normally closed
programmable or pulse
normally open /normally closed
programmable or analogue (4...20 mA / 0...10 V,
scalable)
Ambient temperature [°C] -10...60
Medium temperature [°C] -10...70
Pressure resistance [bar] 16
Reverse polarity / overload protection • / •
Measuring range temperature [°C] -20...80
TypeSM
Accessories
Type Description Orderno.
Connectors and splitter boxes
Type Description Orderno.
Socket, M12,2 m black, PUR cable EVC004
Socket, M12,5 m black, PUR cable EVC005
Applications:Conductive liquids (conductivity: ≥ 20 μS/cm / viscosity: < 70 mm2/s at 40 °C)
Flow sensors
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
Output function OUTSM6050
analogue(4...20 mA)
Output function OUTSM6004, SM7004, SM8004
2 x analogue(4...20 mA, scalable)
For further technical data please go to: www.ifm.com
0.2...50 0.1 l...50 000 m3 < 0.150 (dAP = 0) ± (2 % MV + 0.5 % VMR) G 3/4 SM7000
0.2...100 0.1 l...100 000 m3 < 0.150 (dAP = 0) ± (2 % MV + 0.5 % VMR) G 1 SM8000
Current rating [mA] 2 x 200
Socket, M12,10 m black, PUR cable EVC006
Adapter G 1/2 - G 3/4, pack quantity2 pcs., high-grade stainless steel E40189
Adapter G 1/2 - R 1/2, pack quantity2 pcs., high-grade stainless steel E40199
M12-Steckverbindung · DC PNP/NPN · with display · EPDM O-rings
0...25 0,05 l...30 000 m3 < 0.150 (dAP = 0) ± (2 % MV + 0.5 % VMR) G 1/2 SM6100
0.2...50 0,1 l...50 000 m3 < 0.150 (dAP = 0) ± (2 % MV + 0.5 % VMR) G 3/4 SM7100
0.2...100 0,1 l...100 000 m3 < 0.150 (dAP = 0) ± (2 % MV + 0.5 % VMR) G 1 SM8100
M12-Steckverbindung · DC · with display · FKM O-rings
0...25 – < 0.150 (dAP = 0) ± (2 % MV + 0.5 % VMR) G 1/2 SM6004
0.2...50 – < 0.150 (dAP = 0) ± (2 % MV + 0.5 % VMR) G 3/4 SM7004
0.2...100 – < 0.150 (dAP = 0) ± (2 % MV + 0.5 % VMR) G 1 SM8004
M12 connector · DC · without display · FKM O-rings
0...25 – < 0.150 (dAP = 0) ± (2 % MV + 0.5 % VMR) G 1/2 SM6050
Adapter, G 3/4 - R 1/2, pack quantity2 pcs., high-grade stainless steel E40178
Adapter, G 1 - R 1/2, pack quantity2 pcs., high-grade stainless steel E40179
Grounding clamp G 1/2 E40196
Grounding clamp G 3/4 E40197
Grounding clamp G 1 E40198
56
product news
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
On-site control monitorfor the flexible connection offlow sensors.
For the connection of sensors withlarge immersion depths.
For sensors made of ceramics,high-grade stainless steel and titanium.
Teach button allows easy scalingof the measuring range.
Flow and switch point are indicatedby LEDs directly on the unit.
Available in DC and AC versions.
Flow monitoring in a return pipe witha large nominal width.
High flexibilityStandardised M12 connections are used to connect con-trol monitor and sensor as well as the supply. This allowsthe use of an evaluation and display unit in differentapplications, e.g. for different immersion depths and awide range of aggressive liquids.
Easy handling and high functionalityAdjustment to the flow and setting of the switch pointsare carried out by pressing a pushbutton. Flow and switchpoint are indicated by a multicolour LED display. High re-peatability of the switch points offers an optimum choicefor use.Electronic locking of the settings and factory reset of theparameters provide additional safety.
for field applications.Modular flow monitoring
57
11.2009
Flow sensors
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
For further technical data please go to: www.ifm.com
Operatingvoltage
[V]
Currentconsumption
[mA]
Protection Power-ondelay time
[s]
Ambienttemperature
[°C]
Orderno.
M12 connector · electrical design DC PNP / AC, relay
19...36 DC < 75 IP 67 10 -20...60
Switch pointadjustment
viapushbuttons
Material
stainless steel(304S15) SR5900
Dimensions
Accessories
Type Description Orderno.
Protective cover,PP colourless E40203
Connectors and splitter boxes
Type Description Orderno.
Control monitor for flow sensors of the SF series
* aluminium oxide, 99.7 %
Setting rangeliquid / gaseous
[cm/s]
Mediumtemperature
[°C]
Responsetime[s]
Temperaturegradient[K/min]
Pressureresistance
[bar]
Orderno.
M12 connector · process connection adapter
3...300 / 200...3000 -25...80 1...10 300 300
Sensorlength[mm]
44
Material
stainless steel(316S12) SF5200
3...300 / 200...3000 -25...80 1...10 300 30 55 stainless steel(316S12) SF5201
M12 connector · process connection clamp adapter · with flexible immersion depth
3...300 / 200...3000 -25...80 1...10 30 30 191 stainless steel(316S12) SF6200
M12 connector · process connection G 1/4 male, G 1/2 male, adapter · for aggressive media
3...60 / - 5...70 2...20 7 30 12 ceramics* SF2405
3...60 / - 5...70 2...20 7 30 12 ceramics* SF3405
3...300 / 200...3000 -25...80 1...10 300 300 44 titanium (3.7035) SF5700
Sensors for connection to control monitor
M12 socket,2 m black, PUR cable EVC001
M12 socket,5 m black, PUR cable EVC002
M12 socket,2 m black, PUR cable EVC004
M12 socket,5 m black, PUR cable EVC005
Wiring diagram
1) LED display2) setting pushbutton3) connection for voltage supply and output signals4) connection for flow sensor
90...240 AC < 45 IP 67 10 -20...60 über Taster stainless steel(304S15) SR5906
27
64
M12
x1
4
1 2
835248
50
19,7
3
SR5900
L+
L
1
4
3
1
3
4
2
5
n.c.
L1
N
Out
SR5900 SR5906
58
product news
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
Inline measurement for smalldosing quantities.
Suitable for water and aqueous solutionsup to 200 ml/min.
With flow rate, totalising andtemperature indication.
Fast response time and high responsesensitivity.
4-digit alphanumeric LED display forrepresentation of the measured data.
Process connection G 1/8.
Sensor for the measurement of smallestdosing quantities.
Measurement techniqueThe volumetric flow sensor SQ operates according tothe calorimetric measuring principle. Two measuring el-ements as well as a heat source are located on the measur-ing pipe. The physical effect that a flowing mediumabsorbs heat energy and conducts it away is used. Theresulting temperature change is an indication of flow.
Device functionThis volumetric flow sensor has been designed for thedosing of water and aqueous solutions and offers a widerange of applications. The measuring pipe itself is insidethe unit, offering high protection against mechanicalstrain and measurement influences. Analogue, binary andpulse outputs offer various possibilities to process themeasured data.
smallest quantities at low cost.Safe measurement of the
59
04.2009
Flow sensors
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
For further technical data please go to: www.ifm.com
Measuring rangeFlow
[ml/min]
Pulse value
[ml]
Response timeFlow
[s]
AccuracyFlow
Processconnection
Orderno.
M12 connectors, gold-plated contacts · electrical design DC PNP
1...200 0.1...2 000 000 000 < 0.3 (dAP) = 0)* /2.5 (dAP = 0)**
≤ 100 ml/min: ± (5 % MV + 0.8 % VMR /> 100 ml/min: ± 15% MV) G 1/8 SQ0500
Further technical data
Operating voltage [V] 19...30 DC
Short-circuit protection, pulsed •
Housing materials
high-grade stainless steel(316S12), PC (APEC),Makrolon, PBT-GF 20,
Viton
Sensor material high-grade stainless steel(316S12)
Measuring range temperature [°C] 0…60
Pressure resistance [bar] 10
Reverse polarity / overload protection • / •
Current consumption [mA] < 110
TypeSQ0500
Dimensions
Connectors and splitter boxes
Type Description Orderno.
M12 socket,2 m black, PUR cable EVC004
M12 socket,5 m black, PUR cable EVC005
M12 socket,10 m black, PUR cable EVC006
L+
LOut 2Out 1
2:4: 3
4
2
1
L
L+
Out 2Out 1
2:4: 3
4
2
1
Wiring diagram
Application:Water and aqueous solutions
* for flow increase, ** for flow decrease
1) 4-digit alphanumeric display2) programming button
Current rating [mA] 2 x 250
M12
x1
100111
114
4,5
56
45
1 2
G8
1
48
65
3710
60
product news
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
Suitable for water, oil andglycol solutions.
For volumetric flow quantitiesup to 200 l /min.
Measurement of non-conductive wateralso possible.
Binary, analogue and pulse outputs forsignal processing.
Flow rate, totalising and mediumtemperature indication.
Different process connections possibleusing adapters.
Ultrasonic flow rate measurement in a water circuit forquantity monitoring.
Measuring principleThe ultrasonic flow rate sensor of type SU operatesaccording to the transit time difference principle.Two sound transducers are positioned in a defined pipelength. These sound transducers alternately emit soundpulses. The pulse trains emitted with the flow in the pipelength are transported faster to the receiver by the flow-ing medium. This transit time difference results in thecurrent volumetric flow quantity.
High functionalityIn addition to simple flow rate monitoring the SU alsomonitors the temperature of the medium. It is displayedon the unit and provided for signal processing. The sys-tem is particularly suited for monitoring cooling circuits.
robust inline design.Ultrasonic flow rate sensor in
61
04.2009
Flow sensors
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
For further technical data please go to: www.ifm.com
Measuring rangeFlow
[l/min]
Pulse value Response timeFlow
[s]
AccuracyFlow
Processconnection
Orderno.
M12 connectors · output function 2 x or analogue (4...20 mA / 0...10 V) · DC PNP/NPN
0...50 0.1 l...10 000 m3 < 0.250 (dAP = 0) < ± (3 % MV + 0.2 % VMR)* /< ± (5 % MV + 0.5 % VMR)** G 3/4 SU7000
0...100 0.1 l...10 000 m3 < 0.250 (dAP = 0) < ± (3 % MV + 0.2 % VMR)* /< ± (5 % MV + 0.5 % VMR)** G 1 SU8000
0...200 0.1 l...100 000 m3 < 0.250 (dAP = 0) < ± (3 % MV + 0.2 % VMR)* /< ± (8 % MV + 0.5 % VMR)** G 1 1/4 SU9000
M12 connectors · output function 2 x · DC PNP
0...50 – < 0.250 (dAP = 0) < ± (3 % MV + 0.2 % VMR)* /< ± (5 % MV + 0.5 % VMR)** G 3/4 SU7200
0...100 – < 0.250 (dAP = 0) < ± (3 % MV + 0.2 % VMR)* /< ± (5 % MV + 0.5 % VMR)** G 1 SU8200
Further technical data
Operating voltage [V] 19...30 DC
Short-circuit protection, pulsed •
Housing material housingseal
plug housing
cover film
AlMgSi0,5 anodised;Viton;
Optalloy-platedbrass
PA 6.6;polyamide
Sensor material
high-grade stainless steel(316 L); PPR (Hostalen);
Viton; PES (Ultrason 2010);Centellen 200
Pressure resistance [bar] 16
Protection IP 67, III
Reverse polarity / overload protection • / •
Measuring range temperature [°C] -10...80
TypeSU
Accessories
Type Description Orderno.
Adapter, G 3/4 - R 1/2, pack quantity2 pcs., high-grade stainless steel E40178
Adapter, G 1 - R 1/2, pack quantity2 pcs., high-grade stainless steel E40179
Adapter, G 1 - R 3/4, pack quantity2 pcs., high-grade stainless steel E40180
Connectors and splitter boxes
Type Description Orderno.
M12 socket,2 m black, PUR cable EVC004
M12 socket,5 m black, PUR cable EVC005
M12 socket,10 m black, PUR cable EVC006
Wiring diagram
Robust aluminium housing4-digit alphanumeric display for the units of measurement l /min, m3/h and °C
* for water,** for glycol (35 %) and oil (viscosity: 68 mm2/s at 40 °C)
Adapter, G 1 1/4 - R 1, pack quantity2 pcs., high-grade stainless steel E40205
SU7000, SU8000, SU9000
4
1
3
2 OUT2/InD
L+
L
BN
BUOUT1
WH
BK
L+
LOUT1OUT2
4:2:
4
2
1
3
SU9004
2
L
L+4
1
3Out 1Out 2
4:2:
SU7200, SU8200
M12 connectors · output function 2 x analogue (4...20 mA, scalable) · DC
0...200 – < 0.250 (dAP = 0) < ± (3 % MV + 0.2 % VMR)* /< ± (8 % MV + 0.5 % VMR)** G 1 1/4 SU9004
62
product news
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
Reliable flow control forinternal drill cooling.
Flow rates:25 l/min, 50 l/min, 75 l/min.
Pressure ranges up to 200 bar.
Switch points can be (pre)setcontinuously.
Binary or analogue signal output.
Response time ≤ 10 ms.
Mechatronic sensor on the high-pressure side of coolantlubrication of a machine tool.
Mechatronic flow sensorThe flow sensor works to the principle of spring-support-ed piston: The piston located in the valve seat in thehousing is lifted by the flowing medium against thespring resistance. The piston position is detected in abinary way via an inductive sensor or in an analogueway via a sensor with GMR cell.The spring resistance leads to reliable reset of the pistonto its initial position with decreasing flow. This ensuresposition-independent installation of the flow sensor pre-venting backflow.The switch points can be individually set and fixed via asetting screw. The robust mechanical design ensures useat high pressures and in harsh environments. The unitsare maintenance-free.
Fast, mechatronic flow sensor.
63
04.2009
Flow sensors
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
For further technical data please go to: www.ifm.com
Common technical data
Operating voltage [V] 24 DC (-15 % / + 10 %)
Short-circuit protection •
Materials (wetted parts)
brass,stainless steel (316S16),aluminium, anodised;O-ring: FPM (Viton)
Ambient temperature [°C] 0...60
Medium temperature [°C] 0...60
Switching status [LED] yellow (4 x 90°)
Process connection G 1/2
Reverse polarity / overload protection • / •
Repeatability 1 % of the final value
TypeSBU
Dimensions
Protection IP 67, III
30
G2
1
57
8015
0...1
67
40
18
G 21
8068
40
6,3
26
3
L+
L
1
4L+
L
1
3
2
Wiring diagram
SBU323, SBU324, SBU325
Example SBU323
SBU623, SBU624, SBU625
Setting range
[l/min]
Hysteresis
[l/min]
Responsetime[s]
Accuracy
[% of the final value]
Currentrating[mA]
Orderno.
M12 connector · output function NO · electrical design DC pnp
0.3...25 0.1...1 ≤ 0.01 ± 5 (not linear) 100 SBU323
M12 connector · output function analogue · electrical design DC
0.3...25 – ≤ 0.01 ± 5 (not linear) –
Analogue output
[V]
–
0.3...50 0.2...2 ≤ 0.01 ± 5 (not linear) 100 SBU324–
0.3...75 0.3...3 ≤ 0.01 ± 5 (not linear) 100 SBU325–
(0.3-1)...10 V (10000 Ω) SBU623
0.3...50 – ≤ 0.01 ± 5 (not linear) – (0.3-1)...10 V (10000 Ω) SBU624
0.3...75 – ≤ 0.01 ± 5 (not linear) – (0.3-1)...10 V (10000 Ω) SBU625
Connectors and splitter boxes
Type Description Orderno.
M12 socket,2 m black, PUR cable EVC001
M12 socket,5 m black, PUR cable EVC002
M12 socket,2 m black, PUR cable EVC004
M12 socket,5 m black, PUR cable EVC005
M12 socket,2 m orange, PVC cable EVT064
M12 socket,5 m orange, PVC cable EVT001
M12 socket,2 m orange, PVC cable EVT067
M12 socket,5 m orange, PVC cable EVT004
Application:Machine tools, internal drill cooling
64
product news
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
Binary volumetricflow sensors for liquids.
Volumetric flow quantities: 15 l/min,25 l/min, 50 l/min, 100 l/min, 200 l/min.
Fast response time ≤ 10 ms.
Easy handling: Switch points can be(pre)set continuously.
Binary switching output.
Pressure range 25 bar.
Mechatronic sensor in the coolant circuit of an inductionfurnace.
Mechatronic flow sensorThe flow sensor works to the principle of spring-support-ed piston: The piston located in the valve seat in thehousing is lifted by the flowing medium against thespring resistance. The piston position is detected via aninductive sensor and is output as a binary signal.The spring resistance leads to reliable reset of the pistonto its initial position with decreasing flow. This ensuresposition-independent installation of the flow sensor andbackflow is prevented.The switch points can be easily set and fixed via a settingscrew. The robust mechanical design ensures use in harshenvironments. The units are maintenance-free.
Robust mechatronic flow sensor.
65
04.2009
Flow sensors
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
For further technical data please go to: www.ifm.com
Common technical data
Materials (wetted parts)
stainless steel(304C15 / 301),
nickel-plated brass,Pocan; O-ring: NBR
Current rating [mA] 100
TypeSBY
Dimensions
113...123,576,5
32
97...
105,
5
G4
3
G4
3
3
L+
L
1
4
Wiring diagram
Example SBY332
Pressure loss
[bar]
M12 connector · output function NO · electrical design DC pnp
1...15 0.2...1 ≤ 0.01 ± 5 0.05...0.2 SBY332
Process connection
G 3/4
1...25 0.5...2 ≤ 0.01 ± 5 0.2...0.75 SBY333G 3/4
2...50 1...3 ≤ 0.01 ± 5 0.25...0.8 SBY334G 3/4
5...100 3...6 ≤ 0.01 ± 5 0.1...0.9 SBY346G 1
20...200 5...10 ≤ 0.01 ± 5 0.1...0.2 SBY357G 1 1/2
Application:Liquids
Setting range
[l/min]
Hysteresis
[l/min]
Responsetime[s]
Accuracy
[% of the final value]
Orderno.
Operating voltage [V] 24 DC (-15 % / + 10 %)
Short-circuit protection •
Ambient temperature [°C] 0...60
Medium temperature [°C] 0...85
Switching status [LED] yellow (4 x 90°)
Reverse polarity / overload protection • / •
Repeatability 1 % of the final value
Protection IP 67, III
Connectors and splitter boxes
Type Description Orderno.
M12 socket,2 m black, PUR cable EVC001
M12 socket,5 m black, PUR cable EVC002
M12 socket,2 m black, PUR cable EVC004
M12 socket,5 m black, PUR cable EVC005
M12 socket,2 m orange, PVC cable EVT064
M12 socket,5 m orange, PVC cable EVT001
M12 socket,2 m orange, PVC cable EVT067
M12 socket,5 m orange, PVC cable EVT004
All data refer to water.
66
Compact pressure sensorfor applications in roboticsand handling.
PQ pressure sensor – for pneumatic applicationsThe new pressure sensors of the PQ series are based on apiezoresistive measuring element and are distinguished byan extremely compact housing and a wide range of pos-sible applications. The units precisely measure the pressurein the negative pressure and overpressure range in pneu-matic applications. The silicon measuring cell is insensitiveto liquids (e.g. condensed water) and deposits that mightoccur in the system.
Technical detailsThe silicon measuring cell used guarantees a high overloadresistance as well as an accuracy of ± 0.5 %. The sensorcan be programmed using two pushbuttons. The two-colour, four-digit display makes the system pressure visiblefrom a distance in normal operation.
product news
Slanted display for good readabilityand handling.
Two-colour display for indication of theswitching status.
Easy installation using integratedmounting holes and accessories.
Two programmable switching outputsor one switching and diagnostic output.
Pressure range -1...1 bar or -1...10 bar.
A breath of fresh air inpneumatics.
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
67
11.2009
Accessories
Type Description Orderno.
DIN rail clip with 2 socket head screwsM4, stainless steel (1.4310/301) E37340
Adapter R1/8 - R 1/8, rotatable,nickel-plated brass E37350
T pipe mounting set G1/2 with reducer,nickel-plated brass E37360
Connector for standard tube,Ø 6 mm, 4 pcs. E30076
Connector for standard tube,Ø 8 mm, 4 pcs. E30077
Operating voltage [V DC] 18...32
Short-circuit protection, pulsed •
Reverse polarity protection •
Overvoltage protection up to 40 V
Current rating [mA] 100
Current consumption [mA] < 50
Accuracy / deviation(in % of the span)Switch point accuracyDeviation of the characteristics
HysteresisRepeatabilityLong-term stabilityTemperature coefficients (TEMPCO)in the temperature range 0...60 °C(in % of the span per 10K)Greatest TEMPCO of zeroGreatest TEMPCO of the span
< ± 0.5< ± 0.25 (BFSL)
< ± 0.5 (LS)< ± 0.25< ± 0.1
< ± 0.05
0.20.2
Type of pressure: relative pressurecompressed air
Common technical data
Switching frequency [Hz] ≤ 170
Medium temperature [°C] 0...60
Protection IP 65, III
Shock resistance 50 g
Vibration resistance 20 g
Housing materialsPBT (Pocan),FPM (Viton),
polyester
Materials (wetted parts)brass, FPM (Viton),
silicon (plated),PBT (Pocan)
M8 connector · output function 2 x programmable or 1 x + diagnosis
-1...1 20 PQ7809
-1...10 20 PQ7834
30
30
-0.97...1
-0.90...10
-0.98...0.99
-0.95...9.95
0.005
0.05
Process connection G 1/8PNP switching
Measuring rangeRelative pressure
[bar]
Orderno.
Poverloadmax.[bar]
Pburstmin.[bar]
Connectors and splitter boxes
Type Description Orderno.
Socket , M8,2 m black, PUR cable E11199
Socket , M8,5 m black, PUR cable E11200
Socket , M8,2 m black, PUR cable E11196
Socket , M8,5 m black, PUR cable E11197
Set pointSP1 / SP2
[bar]
Reset pointrP1 / rP2
[bar]
Stepincrement
[bar]
Mounting optionsThe sensor can be fixed to flat surfaces and profilesusing the two M4 drill holes on the front. It can be fixed toa DIN rail using the robust DIN rail clip, which is securedagainst inadvertent movement. The sensor is screwed tothe clip.Installation with an optional double nipple with 1/8"thread is even easier. Using this nipple, the sensor can befixed to the pipe or air-ducting plate and aligned at thesame time – quickly and easily.
Pressure sensors
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
For further technical data please go to: www.ifm.com
68
Good readability andelectronic signal processingmean reliable operation.
Optimum readability by electronicallydamped pointer display.
Rotatable display with LED bargraph forswitch point indication.
Output functions programmable viaLED display and optical touch fields.
Hygienic flush design and high totalaccuracy (0.2 %).
Aseptoflex Vario – new G 1 processconnection with 4 sealing options.
Electronic “contact manometer” PGIn the process industry mechanical contact manometersare often used because of their highly visible display. Theelectronic “contact manometer” of the series PG com-bines the high visibility of a manometer display with theadvantages of an electronic pressure sensor. Compared tomechanical contact manometers it features more variedoptions.The basic unit is a high-quality pressure sensor designedfor the process industry completed by an analogue dis-play with high readability. Especially the programmableswitching output and analogue output (scalable), thehigh overload protection as well as the integrated tem-perature compensation are worth mentioning. Themanometer has a resolution of 0.25 %. When discon-nected, the pointer is not visible.
sensor and analogue display.Fusion of electronic pressure
product news
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
69
04.2009
Output function switching output PNP/NPN programmable + analogue output programmable
-1...25 40 PG2793
-1...10 16 PG2794
-1...4 6.4
100
50
30
-1.00...33.76
-1.0...13.50
-1.00...5.40
5.24...40.00
1.5...16.00
0.00...6.40 PG2795
Flush manometer with G 1 process connection
Measuring rangeRelative pressure
[bar]
Orderno.
Extendeddisplay range
[bar]
Poverloadmax.[bar]
Analoguestart point
[bar]
Analogueend point
[bar]
-0.96...40.00
-0.98...16.00
-0.99...6.40
-0.124...2.5 4 PG2796
-0.05...1 1.6 PG2797
-0.0124...0.25 0.4
20
10
10
-0.124...3.370
-0.05...1.35
-0.0124...0.3376
0.500...4.000
0.2...1.60
0.05...0.40 PG2798
-0.120...4.000
-0.048...1.60
-0.012...0.40
Set pointSP1[bar]
-1.00...39.96
-1.00...15.98
-1.00...6.39
-0.124...3.996
-0.05...1.598
-0.0124...0.3996
-1...1 1.6 PG2799
-0.005...0.1 0.16
10
4
-1...1.1
-0.005...0.135
-0.5...1.6
0.02...0.16 PG2789
-0.998...1.6
-0.0048...0.16
-1...1.598
-0.005...0.1598
Reset pointrP1
[bar]
Connectors and splitter boxes
Type Description Orderno.
Operating voltage [V DC] 18...32
Current rating [mA] 250
Current consumption [mA] < 45
Programming options
hysteresis / window,NO / NC, switching logic,current output, damping,adaptation of displayed
values,scalable, display unit,
2-point calibration
Accuracy / deviation(in % of the span) turn down 1:1Deviation of the switch pointDeviation of the characteristicsLinearityHysteresisRepeatabilityLong-term stabilityTemperature coefficients (TEMPCO)in the temperature range 0...70 °C(in % of the span per 10 K)Greatest TEMPCO of zeroGreatest TEMPCO of the span
PG279x
< ± 0.2< ± 0.2
< ± 0.15< ± 0.15< ± 0.1< ± 0.1
< ± 0.05< ± 0.15
Type of pressure: relative pressureLiquids and gases
Common technical data
Medium temperature [°C] -25...125(145 max. 1 h)
Housing materials
high-grade stainless steel(316S12);
PTFE, FPM (Viton), PA,laminated safety glass
Materials (wetted parts)
high-grade stainless steel316L (1.4435);
ceramics (99.9 % Al2O3);PTFE
Socket, M12, 4-pole,5 m orange, PVC cable EVT004
Socket, M12, 4-pole,10 m orange, PVC cable EVT005
You can find suitable process adapters on ourwebsite at: www.ifm.com
Pressure sensors
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
For further technical data please go to: www.ifm.com
PG2789
< ± 0.5< ± 0.5
< ± 0.25< ± 0.2< ± 0.1< ± 0.1
< ± 0.1< ± 0.2
The electronic “contact manometer” features thefollowing advantages:• 3 units in one: analogue display, transmitter and
switch – without using relays or switching amplifiers• Parameterisable functions (switch points, NC / NO,
hysteresis etc.) facilitate the selection of units andreduce the variety of types
• Higher accuracy by electronic processing ofmeasured values
• High-quality 99.9 % ceramic measuring cellwith Aseptoflex Vario process adapter
• Wear-free, even in case of dynamic load changes• Excellent overload protection• Excellent vibration and shock resistance
(no filling for vibration absorber or pressure transfernecessary)
• Exact orientation by rotatable display• Hardened 4 mm safety glass• Low weight (no mechanics)• Easy specification of the right “manometer”
Aseptoflex Vario – the new process connectionwith 4 sealing optionsThe new process connection Aseptoflex Vario with G 1thread enables sealing via a metal sealing edge, O-ringsof various materials (e.g. EPDM or FKM), a PEEK ring orcommon sealing materials (e.g. teflon tape). Variousprocess adapters (clamp, DIN11851 pipe fittings, etc.)are available as accessories.In addition, the G 1 thread fits into conventional adaptersand T-pieces. Sealing at the thread via an additional slotwhich can locate an O-ring or flat seal is possible.
70
product news
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
Now with enhancedsealing system.
High overall accuracy (0.2 %) andelectronic temperature compensation.
Programmable analogue andswitching output.
Hygienic, flush design withhigh-purity ceramic measuring cell.
Aseptoflex Vario – new G 1 processconnection with 4 sealing options.
High temperature resistance, thereforesuitable for SIP and CIP processes.
Special stress – special materialsThe new pressure sensors of the PI27 series have a high-grade stainless steel housing (316S12). The housingdesign is, in particular, distinguished by its resistance tocleaning agents used in the food and pharma industrieswhose effectiveness is constantly increasing. Lasered,captive type labels are natural for these sensors.The excellent features and characteristics of the formerPI sensors are also provided by the new series: high pro-tection IP 69K, hygienic design, high temperature resis-tance, high-purity ceramic measuring cell, high-qualitymaterials (wetted parts) and last but not least intuitiveoperation.
hygienic applications.Full-metal pressure sensors for
71
04.2009
Pressure sensors
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
For further technical data please go to: www.ifm.com
Output function PNP/NPN programmable + analogue output programmable
-1...25 PI2793
-1...10 PI2794
-1...4
100
50
30
-1.00...18.74
-1.0...7.5
-1.00...3.00
5.24...25.00
1.5...10.00
0.00...4.00 PI2795
Accessories
Type Description Orderno.
Aseptoflex Vario adapter on clamp 1-1.5"with PEEK / elastomeric O-ring E33201
Aseptoflex Vario adapter on clamp 1-1.5"with metal-on-metal sealing E33701
Aseptoflex Vario adapter on clamp 2"with PEEK / elastomeric O-ring E33202
Aseptoflex Vario adapter on clamp 2"with metal-on-metal sealing E33702
Aseptoflex Vario adapter to DIN 11851DN40 (1.5") with PEEK/elastomeric O-ring E33212
Aseptoflex Vario adapter to DIN 11851DN40 (1.5") with metal-on-metal sealing E33712
Aseptoflex Vario welding adapter E30122
FKM (Viton) sealing ringfor Aseptoflex Vario E30123
Flush pressure sensors with G 1 process connection.
Measuring rangeRelative pressure
[bar]
Orderno.
Poverloadmax.[bar]
Analoguestart point
[bar]
Analogueend point
[bar]
-0.96...25.00
-0.98...10.00
-0.99...4.00
-0.124...2.5 PI2796
-0.05...1 PI2797
-0.0124...0.25
20
10
10
-0.124...1.880
-0.05...0.75
-0.0124...0.1874
0.500...2.500
0.2...1.00
0.05...0.25 PI2798
-0.120...2.500
-0.048...1.00
-0.012...0.25
Set pointSP1[bar]
-1.00...24.96
-1.00...9.98
-1.00...3.99
-0.124...2.496
-0.05...0.998
-0.0124...0.2496
-1...1 PI2799
-0.005...0.1
10
4
-1...0.5
-0.005...0.075
-0.5...1
0.02...0.1 PI2789
-0.998...1
-0.0048...0.1
-1...0.998
-0.005...0.098
Reset pointrP1
[bar]
0.02
0.01
0.005
0.002
0.001
0.0002
0.001
0.0001
Stepincrement
[bar]
Aseptoflex Vario – the new connection with4 sealing options.The advantage of the flexible Aseptoflex adaptation withmetal-on-metal sealing was kept and complementedwith a maintenance-free PEEK sealing. If you, however,prefer sealing by means of an O-ring, you can use thesame adapter. In this case, the flexible disk spring en-sures reliable. The sealing between the housing and theprocess connection ensures that the sensor can also bescrewed into the standard G 1 A thread sleeves usingthe common sealing technology.Various process adapters (clamp, DIN11851 pipe fitting,etc.) are available as accessories.
Operating voltage [V DC] 18...32
Current rating [mA] 250
Short-circuit protection, pulsed •
Reverse polarity / overload protection • / •
Integrated watchdog •
Current consumption [mA] < 50
Programming options
Hysteresis / window,NO / NC, output logic,
current output,damping, calibration of
displayed values,display can be rotated /deactivated, scalable,
display unit
Accuracy / deviation(in % of the span) turn down 1:1Deviation of the switch pointDeviation of the characteristicsLinearityHysteresisRepeatabilityLong-term stabilityTemperature coefficients (TEMPCO)in the temperature range 0...70 °C(in % of the span per 10 K)Greatest TEMPCO of zeroGreatest TEMPCO of the span
PI279x
< ± 0.2< ± 0.2
< ± 0.15< ± 0.15< ± 0.1< ± 0.1
< ± 0.05< ± 0.15
Type of pressure: relative pressureLiquids and gases
Common technical data
Medium temperature [°C] -25...125(145 max. 1 h)
Housing materials
stainless steel (316S16),PTFE, ULTEM,
FPM (Viton), PFA,PBT (Pocan)
Materials (wetted parts)
high-grade stainless steel316L (1.4435);
ceramics (99.9 % Al2O3);PTFE
Power-on delay time [s] 0.5
Response time switching output [s] 0.1
Protection IP 67 / IP 68 / IP 69K
PI2789
< ± 0.5< ± 0.5
< ± 0.25< ± 0.2< ± 0.1< ± 0.1
< ± 0.1< ± 0.2
PEEK sealing ringfor Aseptoflex Vario E30124
72
product news
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
Pressure sensors of thePK series – now alsowith 1 switching output.
One NO switching output with fixedhysteresis (2 %).
Mechanical locking prevents inadvertentswitch point manipulation.
Easy switch point setting via setting ringwith optimum readability.
Stainless steel measuring cell withoutseparate seal.
For use in refrigerating technology,hydraulic and pneumatic applications.
Another version of the PK seriesThe pressure sensors of the PK series are now also avail-able with only one switching output. This output is ratedas NO with 2 % hysteresis. In addition to hydraulic andpneumatic applications they are suitable for use in appli-cations where gas pressures up to 400 bar may arise.
The easy operating conceptThe ease of handling is fascinating: Due to the radial set-ting rings with a unit scale for optimum readability,every user can adjust the set point quickly and preciselyeven without pressure being applied. Due to the possiblemechanical locking inadvertent manipulation is excluded.Two clearly visible LEDs indicating the switching statusand readiness for operation provide the required trans-parency.
pressure sensor generation PK.Ingeniously simple: The innovative
73
04.2009
Pressure sensors
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
For further technical data please go to: www.ifm.com
Accessories
Type Description Orderno.
Protective cover for pressure sensorstype PK, transparent plastic E30094
Damping screw for pressure sensorstype PK E30057
Flange adapters G1/4 for pressure sensorsType PK, stainless steel, O-ring: NBR E30063
Operating voltage [V DC] 9.6 ... 32
Short-circuit protection, pulsed •
Reverse polarity protection •
Voltage drop [V] < 2
Current rating [mA] 500
Current consumption [mA] < 25
Accuracy / deviation(in % of the span)Switch point accuracyDeviation of the characteristics
RepeatabilityRepeatabilityTemperature influencein the temperature range 0...80 °C(in % of the span per 10 K)
< ± 2.5< ± 1.5 (BFSL)< ± 2.5 (LS)
< ± 0.5
0.5
Type of pressure: relative pressureLiquids and gases
Common technical data
Switching frequency [Hz] 100
Medium temperature [°C] -25...80
Protection IP 67
Housing materials
PBT (Pocan),PC (Makrolon),
FPM (Viton),high-grade stainless steel
(316S12)
Materials (wetted parts)high-grade stainless steel
(316S12),FPM (Viton)
Dimensions
61,6
12
M12 x127
27
71,6
G1 4/M5
7,5
21
1) tightening torque 25 Nm2) FPM seal / DIN 3869-14
2-wire connection technology
0...400 600 PK5520
0...250 400 PK5521
0...100 200
1600
1000
1000
12...400
7.5...250
3...100
8
5
2 PK5522
0...25 60 PK5523
0...10 25
500
300
0.75...25
0.5...10
0.5
0.2 PK5524
Stainless steel measuring cell welded without any sealProcess connection G 1/4 male, M5 female
Measuring rangeRelative pressure
[bar]
Orderno.
Poverloadmax.[bar]
Pburstingmin.[bar]
SetpointSP
[bar]
Hysteresisfixed[bar]
Connectors and splitter boxes
Type Description Orderno.
M12 socket,2 m black, PUR cable EVC001
M12 socket,5 m black, PUR cable EVC002
Wiring diagram
L+
L
1
4
3
74
product news
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
Pressure transmitterwith analogue voltage orcurrent output.
Compact type withG 1/4 process connection.
Pressure ranges adjusted to hydraulicapplications.
Robust metal housing,high protection rating.
For mobile and industrial applications.
Accuracy < ± 1 %.Repeatability < ± 0.1 %.
The sensorThe PT pressure sensor has a stainless steel measuring cellwith thick film DMS sensor element taken from the PKsensor series. Since the measuring cell is directly weldedwith the housing, no seal in contact with the medium isrequired.The measuring cells have high overload and burstingpressures and are resistant to pressure peaks.
The applicationsThe sensors of type PT are suitable for use in industrialand mobile applications, but also for special hydraulicand pneumatic applications with high operating pressure.The high vibration and shock resistance, the high protec-tion rating and the very good EMC resistance make thePT sensor particularly suitable for use in mobile machines.
the new PT pressure sensor.Small and at a low cost –
75
04.2009
Pressure sensors
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
For further technical data please go to: www.ifm.com
For industrial applications For mobile applications
Wiring diagram
L+
L
1
2
Operating voltage [V DC]PT3PT9
8.5...3216...32
Overload protection •
Reverse polarity protection •
Accuracy / deviation(in % of the span)Deviation of the characteristicsLinearity
HysteresisRepeatabilityTemperature coefficients (TEMPCO)in the temperature range -25...90 °C(in % of the span per 10 K)Temperature coefficient of zeroTemperature coefficient of the span
< ± 1< ± 0.25 (BFSL)
< ± 0.5 (LS)< ± 0.2< ± 0.1
0.40.2
Type of pressure: relative pressureLiquids and gases
Measuring rangeRelative pressure
[bar]
Poverloadmax.[bar]
Pburstingmin.[bar]
Orderno.
Output function 4…20 mA
0...400 600 1600 PT3540
0...250 400 1000 PT3541
0...100 200 1000 PT3542
0...25 60 500 PT3543
0...10 25 300 PT3544
Output function 0…10 V
Common technical data
Medium temperature [°C] -25…90
Protection IP 67 / IP 69K
Housing materialshigh-grade stainless steel
(316S12)TROGAMID
Materials (wetted parts)high-grade stainless steel
(316S12)FPM (Viton)
0...400 600 1600 PT9540
0...250 400 1000 PT9541
0...100 200 1000 PT9542
0...25 60 500 PT9543
0...10 25 300 PT9544
Output function 4…20 mA
0...400 600 1600 PT3550
0...250 400 1000 PT3551
0...100 200 1000 PT3552
0...25 60 500 PT3553
0...10 25 300 PT3554
Output function 0…10 V
0...400 600 1600 PT9550
0...250 400 1000 PT9551
0...100 200 1000 PT9552
0...25 60 500 PT9553
0...10 25 300 PT9554
Stainless steel measuring cell welded without any sealProcess connection G 1/4 male, M5 female
Measuring rangeRelative pressure
[bar]
Poverloadmax.[bar]
Pburstingmin.[bar]
Orderno.
EMC for PT355x / PT955x (mobile applications)EN 61000-4-2 ESD: 4 kV CD / 8 kV ADNoise immunity: according to the automotive directive95/54/EC / 04/104 EC / 05/83/ECISO 11452-2 HF fields: 100 V/m (400...2000 MHz)ISO 11452-4: 100 mA (1…400 Mhz) severity 4ISO 7637-2: severity 3Noise emission: to CISPR 25EN61000-6-1EN61000-6-2
EMC for PT354x / PT954x (industrial applications)EN 61000-4-2 ESD: 4 kV CD / 8 kV ADEN 61000-4-3 HF radiated: 10 V/m (80...1000 MHz)EN 61000-4-4 Burst: 4 kV coupling clampEN 61000-4-5 Surge: 1 kV signal for DC unitsEN 61000-4-6 HF conducted: 10 V
Connectors and splitter boxes
Type Description Orderno.
M12 socket,2 m black, PUR cable EVC001
M12 socket,5 m black, PUR cable EVC002
M12 socket,2 m black, PUR cable EVC004
M12 socket,5 m black, PUR cable EVC005
M12 socket,2 m black, PUR cable EVM001
M12 socket,5 m black, PUR cable EVM002
M12 socket,2 m black, PUR cable EVM004
M12 socket,5 m black, PUR cable EVM005
L+
L
1
3
2
PT3 PT9
individual type may differ
76
Temperature transmitterwith Profibus PA profile 3.01or 4...20 mA output.
TAD temperature transmitter in hygienic applications forCIP and SIP
No more calibrationThe use of two different sensor elements which monitoreach other in the process ensures that a developing sen-sor drift is immediately detected and reliably diagnosed.Furthermore, if one element fails, the process continueswith the second measuring element (backup function).
Profibus PA or 4...20 mA outputThe TAP series complements the tried-and-tested andcalibration-free TAD temperature sensors (4...20 mA).TAP transmitters communicate via the established bussystem Profibus PA. The unit supports the Profibus PAprofile 3.01 “Temperature Transmitter” including the ex-tension for “Installation and Maintenance”with optimiseddiagnostic capabilities
ATEX for the highest demandsThe Profibus PA sensors TAP18A and TAP98A are certifiedto ATEX II 1 G, 1/2 D.
calibration – with Profibus PA and ATEX.Temperature measurement without
Integrated drift monitoring,diagnostic and backup function.
Including free 5-point calibrationcertificate.
Precision of 0.2 K at -10...100 °Cand 0.3 K at -25...-10 / 100...150 °C.
Increased process safetydue to self-monitoring.
Cost savings due to elimination ofcalibration.
product news
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
77
11.2009
Accessories
Type Description Orderno.
Other technical data
Measuring range [°C] -25...150
AccuracyProcess value, drift monitoring(-10...100 °C) [°C](-25...-10 / 100...150 °C) [°C]
± 0.2± 0.3
Materials(wetted parts)
high-grade stainless steel(316S12)
Surface characteristics Ra: < 0.6
Connection M12 connector,Gold-plated contacts
Perm. overload pressure [bar] 50
Self-monitoring temperature sensorfor liquids and gases
Connectors and splitter boxes
Type Description Orderno.
M12 socket,5 m orange, PVC cable EVT001
M12 socket,10 m orange, PVC cable EVT002
M12 socket,5 m orange, PVC cable EVT004
M12 socket,10 m orange, PVC cable EVT005
Resolution [°C] < 0.05
Measuring element Pt1000 / NTC,thermically coupled
Electrical design Orderno.
TAP, Profibus PA profile 3.01, electrically separated, GSD file on supplied CD
Process connection Rod length
[mm]
Response timeT05 / T09
[s]
ATEXcategory
TAD transmitter 4…20 mA · 2-wire or 3-wire operating
4...20 mA (scalable)
4...20 mA (scalable)
Operatingvoltage[V DC]
4...20 mA (scalable)
4...20 mA (scalable)
Programming options: Parameter setting to Profibus PA profile temperature transmitter, version 3.01;I&M parameter, drift and diagnostic functions
Programming options: Threshold for drift warning / alarm; fail-safe; display unit; scaling of the analogue output;redundancy switching; performance diagnostic output; output logic; normally open / normally closed
Adapter G 1/2 female – clamp 1"–1.5" E33401
Adapter G 1/2 female – clamp 2" E33402
Welding adapter ball, G 1/2 E30055
Welding adapter collar, G 1/2 E30056
Temperature sensors
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
For further technical data please go to: www.ifm.com
* other Aseptoflex Vario adapters available
TAD981Aseptoflex Vario 33 15...32 –
TAD181Aseptoflex Vario 87,5 15...32 –
TAD991G 1/2 male 33 15...32 –
TAD191G 1/2 male 87,5
TAP98AProfibus PA Aseptoflex Vario 33 9...32 II 1 G, 1/2 D
TAP18AProfibus PA Aseptoflex Vario 87,5 9...32 II 1 G, 1/2 D
3 / 6
3 / 6
3 / 6
3 / 6
3 / 6
3 / 6 15...32 –
Wiring
PA
PA+2
4
1
3n.c.
n.c.
TAP
2
L+
L
1
L+
L3 BU
4 BK
2 WH
1 BN
2 WH
1 BN
TAD: 1) 2-wire operation, 2) 3-wire operation
Protection IP 68 / IP 69K
Aseptoflex Vario welding adapter*Ø 50 mm E30122
Sealing by O-ring
Aseptoflex Vario adapter*Clamp 2", ISO 2852 E33702
Metal-to-metal seal
Aseptoflex Vario adapter*Varivent type N, DN40 (1.5"), Ø 68 mm E33722
Metal-to-metal seal
Aseptoflex Vario adapter* pipe fitting,DN40 (1.5"), DIN 11851 E33712
Metal-to-metal seal
78
Now with freelyconfigurable operating hoursand event counters.
Freely adjustable counter functionIn addition to the existing functions such as diagnosis,monitoring and trend memory, up to 12 counters cannow be additionally configured and monitored via analarm threshold.Operating hours, load hours (e.g. due to the exceedingof a vibration value or temperature limit value) as well aspulses per time and in total are counted.The actual operating times and load values are automati-cally determined and forwarded to a higher-level system.Performance-based measures can then be introduced inSAP via the RTM software, for example.Further new functions are password protection with vary-ing access levels, broadcast search (to localise further VSEunits in the network), DHCP option and the extension ofthe history function by the counter values.
product news
Frequency-selective vibration monitoringof up to 4 measuring points.
2 analogue inputs for additional sensors.
Ethernet interface for integration intooperational data logging systems.
Load meter(impact, vibration, temperature).
Pulse rate meter (impacts) andpulse totaliser.
Extended diagnostic electronics formachine and operating conditions.
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
79
11.2009
Technical data
Voltage supply [V] 24 DC ±20 %
Protection IP 20, III
Ambient temperature [°C] 0...70
Housing DIN rail 2 inch
Inputs/outputs
Diagnostic electronicsVSE100
Dimensions
50
114
LEDs
2
1
105
35,5
Diagnostic electronics for efector octavisvibration sensors type VSA
Wiring diagram
L+ (24 V DC ±20 %)
1817
2019
1413
1615
2221
2423
65
87
21
43
109
1211
L-OU 1: switch/analog OU 2: switch
IN 1 (0/4...20 mA / pulse)GND 1IN 2 (0/4...20 mA / pulse)GND 2
1234
BNWHBUBK
4321
BKBUWHBN
I/O 7
3029
3231
3433
3635
2625
2827
4344
4142
4748
4546
3940
3738
GNDI/O 8GND
I/O 5GNDI/O 6GND
I/O 1GNDI/O 2GND
I/O 3GNDI/O 4GND
U-OUT (0...10 V)GND
U-IN 1 (0...10 V)GND 1U-IN 2 (0...10 V)GND 2
1234
BNWHBUBK
1234
BNWHBUBK
Data interface Ethernet TCP/IP,(10 / 100 Mbits)
1) Ethernet interface2) Combicon connector with screw terminals (option)
Accessories(to be ordered separately)
Type Description Orderno.
Parameter setting softwareversion 2.4 and higher VES003
octavis OPC server E30114
Cross-over patch cable2 m EC2080
Cross-over patch cable5 m E30112
4 sensor inputs 0...10 mA2 analogue inputs (0/4...20 mA
or 0...10 V or pulse 24 V)1 x digital alarm output
(PNP 100 mA)1x either digital
(PNP 100 mA) or analogue (0/4...20 mA / 0...10 V)
alarm output8 x digital inputs/outputs
(freely configurable) (PNP 100 mA) Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
Diagnostic systems
For further technical data please go to: www.ifm.com
80
Compact vibration monitorwith transmitterand switching output.
Permanent vibration monitoringaccording to ISO 10816.
Switching output with adjustable switchpoint and response delay.
Transmitter signal 4...20 mA for directdisplay at the control desk.
LED display on the unit.
Easy adjustment via two setting ringsallowing optimum read-out.
Monitoring of the overall vibration of rotatingcomponents (fans, centrifuges etc.).
Permanent vibration monitoringThe electronic VK type vibration monitor monitors onlinethe overall vibration condition of machines and equip-ment according to DIN ISO 10816. The sensor measuresthe rms vibration velocity on a non-rotating componentsurface. When an adjustable limit value is exceeded theunit sets to alarm via a switching contact.In addition the characteristic value is provided as currentsignal (4...20 mA) for connection to the process controlsystem.
Easy operating conceptThe easy set-up via 2 radial setting rings allows quicksetting of the switch point and response delay.The protective cap, which can be obtained as an acces-sory, ensures protection against tampering.
made easy.Permanent machine protection
product news
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
81
04.2009
Technical data
Analogue output4...20 mA
(4 mA = 0 mm/s;20 mA = 25 mm/s)
Response delay adjustable from1...60 seconds
Load resistance 500 Ohm
Operating voltage [V] 18...32 DC
Switching output
1 switching output NC,adjustable switch point,PNP, can withstand up to
500 mA
Reverse polarity protection •
Protection IP 67, III
Ambient temperature [°C] -25...80
Housing material high-grade stainless steel,plastic (Makrolon)
Frequency range [Hz] 10...1000
Measuring range [mm/s] 0...25
Measurand Vibration velocityrms
Connection M12 connector
Vibration monitorVKV021
Dimensions
63,7
11
M12 x127
27
73,1
M81
Vibration monitor VKSetting of the switch point and response delay via setting rings directly on the unit.Monitoring of the overall vibration condition of machines and equipment according to ISO 10816.
Accessories(to be ordered separately)
Type Description Orderno.
Protective cover,transparent plastic E30094
Connectors and splitter boxes(to be ordered separately)
Type Description Orderno..
Socket, M12,2 m black, PUR cable EVC001
Socket, M12,5 m black, PUR cable EVC002
Socket, M12,10 m black, PUR cable EVC003
1) Tightening torque 15 Nm
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
Diagnostic systems
For further technical data please go to: www.ifm.com
82
New design for connection tothe diagnostic electronics VSE.
Flat design of approx. 12 mm.
Shielded cable entry on side.
Integrated self-test.
Wide frequency range up to 10 kHz.
Vibration sensor VSA003The accelerometer is used to detect measurement valuesfor the octavis diagnostic electronics VSE.The flat design and the lateral entry of the shielded cablemake it possible to install the unit in locations which aredifficult to access.Using state-of-the-art silicon sensors the sensor sensitivityhas a long-term stability, is temperature-independent andinsensitive to mechanical and electrical interference.
Miniaturised vibration sensor.
product news
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
83
04.2009
Technical data
Measuring range [g] ± 17.5
Protection IP 67, III
Frequency range [Hz] 0...10000
Operating voltage [V] 9 DC
Current consumption [mA] < 15
Housing material stainless steel(316S12)
Contact temperature [°C] -20...80
Ambient temperature [°C] -30...100
Wiring
blue: GNDblack: Testbrown: L+white: Out
Connection PUR cable,1.5 m; 4 x 0.14 mm2
Vibration sensorVSA003
Dimensions
18
11,5
12
1500
5,5
Vibration sensor VSA003for connection to the external diagnostic electronics of the series VSE
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
Diagnostic systems
For further technical data please go to: www.ifm.com
84
Modified, compact vibrationdiagnostic unitwith trend memory.
Permanent vibration monitoringaccording to ISO 10816.
Integrated trend memory fordocumentation and evaluation.
Two switching outputs for warningand alarm.
Frequency-selective online diagnosis(e.g. rolling element bearing, unbalance).
Easy set-up using PC software.
Monitoring of the overall vibration of rotatingcomponents.
Permanent machine monitoring – extended byoverall velocity monitoring according to ISO 10816.The compact vibration diagnostic units of the series VEcombine vibration monitoring, diagnosis and trend mem-ory in a very small space.The integrated accelerometer permanently measures themachine vibrations at a non-rotating component surfaceand also calculates frequency-selective diagnostic valuesas an option in addition to the ISO characteristic values.All calculated characteristic values are stored in a non-volatile internal memory. With a freely adjustable memoryinterval the trend duration can be adapted to the user’sneeds. The unit is easy to use via PC software.
protection and trend analysis.Simply combined: machine
product news
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
85
04.2009
Products
Speed range: 500...6000 rpm
Dimensions
20 M5M
12x1
46,458,2
14
65,3
36
37,6
5,35
10
4
M8x
1
LED
1
Accessories
Type Description Orderno.
Parameter setting softwareversion 1.8 and higher VES001
Parameter setting cablefor RS-232 interface E11572
Parameter setting adapterUSB / RS-485 interface E30098
Power supply E30080
Connectors and splitter boxes
Type Description Orderno.
Socket, M12,2 m black, 5-pole, PUR cable EVC070
Socket, M12,5 m black, 5-pole, PUR cable EVC071
Socket, M12,10 m black, 5-pole, PUR cable EVC072
Common technical data
Current consumption [mA]100 (24 V DC)
(plus optional externalpulse pick-up)
Overload protection [g] 100
Operating voltage [V DC] 10...32
Measuring range ± 25 g(nominal ± 20)
Diagnostic methodspectral analysis,
envelope-curve FFT,trend analysis
Trend memory
2580 data setsas ring memory
per diagnostic quantityor g-monitor
Sensing principle:micromechancial accelerometer /
capacitive measuring principle / one measurement axis
Rolling element bearing diagnosis:2 g-monitors + 2 frequency-selective diagnostic
quantities (e.g. bearing condition)
Orderno.
VB1001
RS-232 interface, LED diagnosisProtection: IP 67, IIIAmbient temperature: -30...60 °CFrequency resolution adjustable: 1.25 or 0.125 HzSpeed range: 12...12000 rpm
Vibration diagnostic unit:2 g-monitors + 5 frequency-selective diagnostic
quantities (e.g. bearing condition)
Orderno.
VE1001
RS-485 interfaceProtection: IP 69K, IIIAmbient temperature: -30...75 °CFrequency resolution adjustable: 1.25 or 0.125 HzSpeed range: 12...12000 rpm
VE1101
Flu
id s
enso
rs a
nd
dia
gn
ost
ic s
yste
ms
Diagnostic systems
For further technical data please go to: www.ifm.com
1) Programming buttons
86
Connection technology complies withthe M12 standard (EN 61076).
With EC type examination certificatefor components from DEKRA EXAM.
The mechanical end stop protectsthe O-ring against destruction.
Nut secured against shock andvibration due to saw tooth contouredvibration protection.
ecolink –a new dimension in connection technology.
even in ATEX applications.ecolink M12, the safe connection
For applications inhazardous areas ATEX cat. 2D,3D and 3G.
ecolink M12 for demanding ATEX applicationsTo avoid the risk of explosion products used in hazardousareas are subject to strict requirements.ifm connectors of the ecolink series comply with thesestrict standard requirements and may be used in ATEXareas of the categories 2D, 3D and 3G.An approval body responsible for Germany, DEKRA EXAM,has type-tested and certified the connectors. The ATEXcomponent certificate is valid in all EU countries.To comply with the ATEX requirements the nut of theconnector has to be tightly screwed to the sensor so thatit is no longer possible to open it manually. Observe therecommended tightening torques of 1.2...1.5 Nm!
product news
Co
nn
ecti
on
tec
hn
olo
gy
bus,identification
and control systems
position sensors
and objectrecognition
fluid sensors and diagnostic
systems
87
11.2009
Technical data:Operating voltage:60 V AC / 60 V DCNominal current: 2 AProtection: IP 67
in locked condition withthe matching counterpart.
Tightening torque of the nut: 1.2...1.5 NmAmbient temperature: -20...60 °CVibration / shock: 750 g, 1 million cyclesCable characteristics: drag chain > 5 million cycles
Materials:Housing / moulded body: TPUContact carrier: GRIVORY GV-GHCoupling nut: high-grade stainless steel (316S12)Contacts: gold-platedSealing ring: VitonCable: PUR, halogen-free, silicone-free,4 x 0.34 mm2, Ø 4.9 mm
Approvals:EC type examination certificate for componentsfrom DEKRA EXAMIECEx BVS 08.0041 UBVS 08 ATEX E 109 UMarking:II 3G Ex nA II Ta: -20...60 °CII 2D Ex tD A21 IP67
Type Description Order no.
NEW
2 m EVC04A
5 m EVC05A
10 m EVC06A
Applications: Factory automation, machine tool industry, construction of machinery,hydraulics, conveying, mills and silos
15,5
M12x1 36,5
26,5
14
Dimensions
Example EVC04A
Sockets M12, 4-pole
Co
nn
ecti
on
tec
hn
olo
gy
Connection technology
For further technical data please go to: www.ifm.com
0.3 m EVC09A
0.6 m EVC10A
1 m EVC11A
2 m EVC07A
5 m EVC12A
10 m EVC13A
Jumper M12, 4-polig
31
1415,5
26,5
1415,5
36,5 36,5M12x1 M12x1
L
Example EVC09A
88
Easy parameter setting of the IO-Linkdevices.
Extended diagnosis for IO-Link devices.
Loss-free data transmission.
IO-Link master for sensors and actuators.
Communication down to the sensor.
AS-i module with 2 IO-Link portsand quick mounting technology
connection.AS-i and IO-Link – a good
AS-i module with 2 IO-Linkports.
AS-i and IO-LinkIO-Link is the intelligent connection between the device(sensor or actuator) on one side and PLC or field moduleon the other side.With the IO-Link AS-i module you combine the advan-tages of the AS-i wiring system with the standardisedIO-Link communication. Using the simple AS-i connec-tion technology you establish the data connection andenergy supply for IO-Link devices – sensors and actua-tors.The sensor settings can be saved via the AS-i module andtransferred to a new sensor, if necessary.
product news
Bu
s sy
stem
s
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
89
04.2009
Technical data
AC5225AS-i IO-Link module 2 ports
Advantages and customer benefits
• ParametersDuring set-up, sensors are fine-adjusted and switchpoints are set. These parameters can be saved in thesystem.If necessary, these parameters are returned to the sen-sors. This ensures error-free documentation and shortdowntimes.
• Exact data transmissionIO-Link and AS-i transfer analogue values in a digitalisedmanner, i.e. without conversion losses. Distorted sig-nals by electromagnetic interference or contact resis-tances are excluded.
• DiagnosisStatus LEDs indicate important AS-i and IO-Link oper-ating states. IO-Link devices transmit additional infor-mation via the standard M12 sensor cable. Exceedingthe operating temperature or measuring range, forexample, is reliably detected. Diagnostic informationcan be transmitted up to the control level. Additionalwiring is not necessary.
• AS-i connection technologyThe AS-i module provides a simple connection techno-logy for data and energy:The yellow flat cable can be inserted from three differ-ent directions. A slide locks upper part and lower part.Quick and secure installation are guaranteed.
ApplicationIO-Link devices are used where a high-precision exchangeof data and high plant uptime are required. Parameterscan be managed and saved centrally. This minimisescomplex parameter setting and shortens machine set-up times.
Applications:• Machine tools• Special machines
Operating voltage (AS-i) [V DC] 26.5...31.5
AS-i current consumption [mA] max. 300
IO-Link current consumption [mA] max. 200 per module (e.g.150 port 1 and 50 port 2)
Sensor supply from AS-i only •
Ambient temperature [°C] -25...70
Protection IP 67
AS-i specification 3.0
IO-Link specification 1.0
AS-i profile S-7.5.5
IO-Link function SIO (DI / DO) /IO-Link communication
Type Description Orderno.
IO-Link sensors (extract)
PP7550
Pressure sensorMeasuringpressure:
max. 400 bar
TN2531
Temperaturesensor
Measuring range:-40...150 °C
TR7432
Control monitorfor temperature
sensorsMeasuring range:
-40...300 °C
SI5010
Flow sensor forliquid and
gaseous mediaPressure
resistance:300 bar
Bu
s sy
stem
s
Bus system AS-interface
For further technical data please go to: www.ifm.com
90
AS-i modules category II 3D.
AS-i pneumatics category II 3D.
Flat cable splitter category II 3D.
Extended addressing mode.
Alignment of the flat cable in 3 directions.
quick mounting technology.AS-i ATEX modules with
Pneumatic digital andanalogue modules for zone 22(non-conductive dusts).
IntroductionIn level applications such as wheat and grain silos, con-centrated feed or animal feed plants there are increaseddemands on the AS-i system and the components used.Appropriate ClassicLine modules and AirBoxes are nowavailable for hazardous areas (zone 22, non-conductivedusts).
Special features• quick mounting of upper and lower parts• digital inputs and outputs and analogue inputs• alignment of the flat cable in 3 directions• extended addressing mode• AirBoxes with slide valves which are free
from overlapping• pressure peak resistance up to 12 bar
product news
Bu
s sy
stem
s
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
91
04.2009
Technical data
AirBox AC246A marking of the unit:II 3D Ex tD A22 IP6x T80 °C X Ta:-10…50 °C
Advantages and customer benefits• Easier installation, addressing and commissioning
The easy mounting of the AS-i modules onto the AS-iflat cable using the new quick mounting technologyprovides maximum security for the user.Slide valve technology, increased pressure peak resis-tance, new valve functions and extended addressingmode are the major new features of the AirBoxes.
• DecentralisationConventional parallel wiring means: many terminals,high wiring complexity and complicated maintenance.Using the yellow AS-i cable ensures that the I /O pointsin the installation can be reached via the shortestdistance. Installation complexity and maintenance arereduced to a minimum.In silo applications the transfer and withdrawal com-partments for transporting the bulk material are evenlydistributed across the installation.Here flap positions are detected, slide positions aresignalled or compartments are actively opened or closed.These tasks can easily be solved by means of the AS-iI /O modules or AirBoxes. The modules provide up to 4inputs and 4 outputs.The AirBoxes connecting an AS-i input module and apneumatic valve are available as 2 x 3 /2-way valve oras 1 x 5 /2-way valve in monostable or bistable design.
Accessories
Type Description Orderno.
Impact protection housing,high-grade stainless steel (430S15) E7000A
Valve function 1 x 5/2 ways
Current rating for 2 inputs [mA] 200
Ambient temperature [°C] -10...50
Protection IP 6x
Extended addressing mode –
Pressure range [bar] 3...8
Operating voltage (AS-i) [V] 26.5..31.6
5 31
4 2
Silencer for the exhaust,Connection piece: PP, filter: PE E75232
E7354A
Flat cable end seal,Housing: ULTRAMID, sealing: NBR E70413
Products
Description Orderno.
ClassicLine modules
ClassicLine 4DI II 3D AC505A*
ClassicLine 2DI 2DO-Y II 3D AC507A*
1 x 5/2 ways monostable, 2DI-Y, profile compatible AC246A*
1 x 5/2 ways bistable, 4DI-Y, A/B slave, AS-i AC551A*
ClassicLIne 4DO II 3D AC508A*
ClassicLine 2DO-Y 2DI-Y II 3D, A/B slave AC514A*
ClassicLine 4DI-Y II 3D, A/B slave AC515A*
ClassicLine 2AI C II 3D AC522A*
ClassicLine 4DI-Y 4DO-Y II 3D, A/B slave AC535A*
AirBoxes
2 x 3/2 ways, 2DI-Y, profile compatible AC542A*
5/2-way valve
* only in conjunction with impact protection housing E7000Aor equivalent protection provided by the user
Accessories
Type Description Orderno.
AS-i flat cable (EPDM), yellow AC4000
AS-i flat cable (EPDM), black AC4002
Splitter box for the flat cable, metal parts:high-grade stainless steel (316S12) E7377A
Bu
s sy
stem
s
Bus system AS-interface
For further technical data please go to: www.ifm.com
Flat cable insulation displacement con-nector, high-grade stainless steel (316S11)
Connectors and splitter boxes
Type Description Orderno.
Jumper, M12, 4-pole,1 m black, PUR cable EVC11A
Jumper, M12, 4-pole,2 m black, PUR cable EVC07A
92
Improved functions for allifm multicode readers.
Orientation-independent readingIndependent of the orientation and the number of codes,the high-performance algorithms automatically decode1D or 2D codes. The optimisation parameters for 1D codeshave been extended.
Code comparator system in the sensorComplex application programming is no longer necessarydue to adjustable, selective code identification and com-parison in the sensor. So, for example, a certain numberof characters in a code can be checked.
UpgradeNew functions include the output of the code position viathe process interface, adjustable total quality parameters,individual illumination settings for each configuration ina group, integrated fault memory and access protectionwith password.
product news
Iden
tifi
cati
on
sys
tem
s
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
New optimisation parameters for1D barcodes.
Adjustable code comparator in the sensor.
Extended barcode library now withRSS 1D barcodes.
Image transmission via process interface.
Selection of the quality parameters toISO / IEC 15415 and 16022.
The new multicode reader withinfrared illumination.
93
11.2009
Multicode reading systems
Type of sensor: CMOS image sensor,black/white, VGA resolution 640 x 480• Readable 2D codes
ECC200, PDF-417, QR• Readable 1D codes
Interleaved 2-of-5, Industrial 2-of-5, Code 39Code 128, Pharmacode, Code 93, CodabarEAN13, EAN13-Add-On 2, EAN13-Add-On 5EAN8, EAN8-Add-On 2, EAN8-Add-On 5UPC-A, UPC-A Add-On 2, UPC-A Add-On 5UPC-E, UPC-E Add-On 2, UPC-E Add-On 5RSS-14, RSS limited, RSS expanded codes
Connectors and splitter boxes
Type Description Orderno.
Socket, M12,2 m PUR cable, 8 poles E11950
Socket, M12,5 m PUR cable, 8 poles E11807
Ethernet, cross-over patch cable,2 m, PUR cable, M12 / RJ45 E11898
Ethernet, shielded patch cable,2 m, PUR cable, M12 / RJ45 E12090
Accessories
Type Description Orderno.
Operating software for multicode reader E2I200
OPC server for multicode reader E2I210
High-grade stainless steel mounting setfor rod mounting Ø 12 mm E2D110
High-grade stainless steel mounting setfor rod mounting Ø 14 mm E2D112
Clamp,high-grade stainless steel, Ø 12 mm E21110
Clamp,high-grade stainless steel, Ø 14 mm E21109
Clamp linking ring,high-grade stainless steel E21076
Common technical data
Operating voltage [V] 24 DC ± 10 %
Current rating [mA] 100 (per switching output)
Current consumption [mA] < 300
Ambient temperature [°C] -10...60
Protection IP 67, III
housingMaterial front lens
LED window
diecast zincglass
polycarbonate
Triggerexternal, 24 V PNP
internal, RS232, TCP/IP,EtherNet/IP
Switching outputs (configurable) max. 2 (configurable)100 mA
Connection external lighting 24 V DC PNP
Parameter setting /process data interface
Ethernet 10Base-T /100Base-TX, RS-232,
EtherNet/IP
Dimensions [mm] 60 x 42 x 53
Motion speed [m/s] max.7
Iden
tifi
cati
on
sys
tem
s
For further technical data please go to: www.ifm.com
Field of view [mm] red light
50 75 100
Operating distance [mm] Orderno.
O2I10020 x 14
O2I10246 x 32
28 x 20
61 x 44
36 x 26
77 x 56
200
68 x 50
140 x 100
Field of view [mm] red light
200 400 1000
Operating distance [mm] Orderno.
O2I10440 x 30 80 x 60 200 x 150
2000
400 x 300
ApplicationThere is a wide range of applications for the multicodereader in industry. From product tracking and productioncontrol to product identification it is used in the followingapplications:• automotive industry• production of solar installations• food industry• conveying• machine tools• print machinesThe standardised process interfaces RS232, Ethernet TCP/IP and EtherNet / IP ensure fast and easy integration in in-dustrial control technology.
Ethernet, cross-over patch cable,10 m, PUR cable, M12 / RJ45 E12204
Ethernet, cross-over patch cable,20 m, PUR cable, M12 / RJ45 E12205
Field of view [mm] infrared
O2I10120 x 14
O2I10346 x 32
28 x 20
61 x 44
36 x 26
77 x 56
68 x 50
140 x 100
Diffuser for O2I E21165
Protective plastic cover for O2I E21166
Protective glass cover for O2I E21168
Laser protection pane for O2I E21169
Field of view [mm] infrared
O2I10540 x 30 80 x 60 200 x 150 400 x 300
94
32 multifunctional inputs,32 multifunctional+ 16 digital outputs.
32-bit ExtendedController for mobile vehiclesThe mobile controller meets the requirements of modernelectronics, able to simultaneously perform proportionalfunctions with a large number of inputs and outputs.The ExtendedController was developed particularly foruse in off-highway and mobile vehicles on the basis ofthe current standards and long-term experience.Besides the multifunctional inputs and outputs eachcontrol module is equipped with 4 CAN interfaces. Theysupport all important bus protocols, different baud ratesand also the transparent and preprocessed data exchange.Programming to IEC 61131-3 ensures that all control func-tions can be easily integrated in the application program.
product news
Analogue and digital I /Os with diagnosticfunction for mobile applications.
Usable for complex control functionsin mobile vehicles.
4 CAN interfaces with CANopen andSAE J1939 protocol.
Freely programmable with CoDeSys 2.3to IEC 61131-3.
e1 type approval of theGerman Federal Office for Motor Traffic.
32-bit ExtendedController formobile vehicles.
Co
ntr
ol s
yste
ms
bus,identification
and control systems
fluid sensors and diagnostic
systems
position sensors
and objectrecognition
95
11.2009
Description Orderno.
ExtendedController 32 Bit CR0232
Connector, 55 poles (wirable) EC2013
Connection cable, plug 55 poles, 1.2 m EC2086
Programming cable with USB adapter, 2 m EC2096
Programming software CoDeSys, German version CP9006
Programming software CoDeSys, English version CP9008
ExtendedControllerCR0232
ProductsFunctions and advantages
• Mechanical structureBesides a reverse-polarity protected central plug formobile applications the control electronics integratedin a compact metal housing provides all the necessaryconnections for the inputs and outputs, communica-tion and programming. The RGB status LED displaysthe most important system messages.
• The electronicsThe core of the controller designed according to theapplicable standards for electronics for mobile applica-tions is a modern 32-bit processor. Monitoring andprotection functions enable safe operation even underextreme operating conditions.
• Configuration of the inputs and outputsBy means of the application software the inputs andoutputs can be configured to adapt to the respectiveapplication.Each input can be configured as a digital, frequency oranalogue input with diagnostic function. In additionthe inputs support the evaluation of positive and nega-tive digital input signals. The analogue inputs enableboth current and voltage measurement.In addition to the freely configurable digital or PWMoutputs with diagnostic capability, with and withoutcurrent control, digital outputs with diagnostic capabilityare also available.
• Parameter setting to IEC 61131-3 with CoDeSysProgramming with the standardised IEC 61131-3 lan-guages enables the user to create clear and easy appli-cation software. In addition, libraries are available forspecial functions of the controller.
• CAN interfaces with CANopen protocolThe ExtendedController is equipped with four CANinterfaces to ISO 11898. The data is exchanged withall connected bus participants via these interfaces. TheCANopen protocol enables quick and flexible connec-tion to the bus. For communication with the dieselengine and the power train all interfaces can be recon-figured to the J1939 protocol.
Applications:• Complex construction machines• Agricultural machines• Municipal vehicles
≤ 320
32
32
Voltage output5/10 V DC, 400 mA 1
Interface
4 x CAN1 x RS 232
1 x virt. COM port(USB)
Supported CAN protocols
CANopen(CiA DS 301 V4.01
and DSP 306)SAE J 1939
Program memory [MB] 1.25
Data memory RAM [kB] 256
Data memory FRAM [kB](non-volatile) 48
Data memory non-volatile [kB] 4
Data memory Auto save [kB] 4
Programming software CoDeSys V2.3
Standards and tests(extract)
CE,e1 (RL 2006/28/EC),
BN 411 002
Outputs digital (2 A) 16
Control systemsfor mobile vehicles
Co
ntr
ol s
yste
ms
For further technical data please go to: www.ifm.com
Technical data
Housingclosed
metal housing withflange fastening
Device connectionAMP connector 55 poles
latched, protected againstreverse polarity
Protection IP 67
Operating voltage [V DC] 10...32
Current consumption [mA]
Temperature range [°C] -40...85
Display RGB LED
Controller Infineon TriCore 1796
Number of inputs (can be configured)digital (positive / negative sensor signals)analogue (0...10 / 32 V, 0...20 mA,ratiometric)Frequency (≤ 30 kHz)
Number of outputs (can be configured)digital, positive / negative switchingPWM output (8 x 4 A, 8 x 2 A)current-controlled(8 x 4 A, 2 A)
ifm electronic –
ifm article no. 7511377 · Printed in Germany on non-chlorine paper.We reserve the right to make technical alterations without prior notice. · 10.2009
www.ifm.com
visit our website:
Overview ifm main catalogues:
Position sensorsand object recognition
Inductive sensorsCapacitive sensorsMagnetic sensors,cylinder sensorsSafety technologyValve sensorsPhotoelectric sensorsObject recognitionEncodersEvaluation systems,power suppliesConnection technology
Fluid sensorsand diagnostic systems
Level sensorsFlow sensorsPressure sensorsTemperature sensorsDiagnostic systemsEvaluation systems,power suppliesConnection technology
Bus systems
Bus system AS-interfacePower suppliesConnection technology
Identification systems
Multicode reading systemsRF-identification systemsPower suppliesConnection technology
Control systems
Control systemsfor mobile vehiclesConnection technology