NETLink PRO PROFIBUS Ethernet gateway NETLink PRO PoE RFC 1006 (ISO on TCP) CPU-to-CPU communication (with S7-300* and S7-400*) Support for all common S7 engineering tools Dynamic address assignment using DHCP Security functions for securing TCP/IP access Switchable PLC write protection Up to 16 TCP connections Up to 32 MPI/PROFIBUS connections Easy configuration via web interface Variables can be monitored in a browser window Support for slave configuration Electrical isolation for MPI/PPI/PROFIBUS MPI/PPI/PROFIBUS from 9.6 kbps to 12 Mbps For S7-200*, S7-300*, S7-400* Powered Device (PD) as defined in IEEE 802.3af (POE) and 802.3at (POE+) In general, connection to each MPI/PROFIBUS terminal of the bus system or directly at the interfaces of active and passive participants is also possible. The PG socket integrated in the connector housing allows connection of additional devices. The integrated web interface offers parameterization, diagnostic, and security features, and for functional enhancements, the user can use our free diagnostic software SHTools to, for example, automatically perform firmware updates. The latest version is available for download. It draws its supply voltage through the CPU of the automation device, or optionally via externally supplied DC 24 V, or a CAT5 network cable using a PoE power supply unit. The NETLink PRO PoE enables the implementation of TCP/IP on the MPI/PPI/PROFIBUS with up to 32 simultaneously open connection channels. With the switchable single-master operation, passive bus participants can be addressed. The integration of SCADA, HMI, and OPC applications is possible via the widely used ISO on TCP (RFC 1006) protocol. The applications are automatically detected and forwarded by the NETLink PRO PoE. Technical specifications General information Order number 700-881-MPI21 Article name NETLink PRO PoE Scope of delivery NETLink PRO PoE, Quick Start Guide, CD with software, and manual Dimensions (DxWxH) 102 x 54 x 30 mm Weight Approx. 180 g Supported operating systems No limitation (the driver for SIMATIC NETLink-S7-NET only Windows XP, 2003R2, 7, 2008R2, 8.1, 2012R2, 10) POE PoE Betriebsspannung 48 V as per IEEE 802.3af/at PoE Leistungsklasse Class 1 (0.44 to 3.84 Watt) Communication interface Number 1 Type 10 Base-T Helmholz GmbH & Co. KG | Hannberger Weg 2 | 91091 Großenseebach | Germany Phone +49 9135 7380-0 | Fax +49 9135 7380-110 | [email protected] | www.helmholz.de Änderungen und Irrtümer vorbehalten. 03-2022

NETLink PRO PoE - Helmholz

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

NETLink PRO PROFIBUS Ethernet gatewayNETLink PRO PoE

RFC 1006 (ISO on TCP)CPU-to-CPU communication (with S7-300* and S7-400*)Support for all common S7 engineering toolsDynamic address assignment using DHCPSecurity functions for securing TCP/IP accessSwitchable PLC write protectionUp to 16 TCP connectionsUp to 32 MPI/PROFIBUS connectionsEasy configuration via web interfaceVariables can be monitored in a browser windowSupport for slave configurationElectrical isolation for MPI/PPI/PROFIBUSMPI/PPI/PROFIBUS from 9.6 kbps to 12 MbpsFor S7-200*, S7-300*, S7-400*Powered Device (PD) as defined in IEEE 802.3af (POE) and802.3at (POE+)

In general, connection to each MPI/PROFIBUS terminal of the bussystem or directly at the interfaces of active and passiveparticipants is also possible. The PG socket integrated in theconnector housing allows connection of additional devices. Theintegrated web interface offers parameterization, diagnostic, andsecurity features, and for functional enhancements, the user canuse our free diagnostic software SHTools to, for example,automatically perform firmware updates. The latest version isavailable for download.

It draws its supply voltage through the CPU of the automationdevice, or optionally via externally supplied DC 24 V, or a CAT5network cable using a PoE power supply unit. The NETLink PROPoE enables the implementation of TCP/IP on theMPI/PPI/PROFIBUS with up to 32 simultaneously openconnection channels. With the switchable single-masteroperation, passive bus participants can be addressed. Theintegration of SCADA, HMI, and OPC applications is possible viathe widely used ISO on TCP (RFC 1006) protocol. Theapplications are automatically detected and forwarded by theNETLink PRO PoE.

Technical specifications

General information

Order number 700-881-MPI21

Article name NETLink PRO PoE

Scope of delivery NETLink PRO PoE, Quick Start Guide, CD with software, andmanual

Dimensions (DxWxH) 102 x 54 x 30 mm

Weight Approx. 180 g

Supported operating systems No limitation (the driver for SIMATIC NETLink-S7-NET onlyWindows XP, 2003R2, 7, 2008R2, 8.1, 2012R2, 10)

POE

PoE Betriebsspannung 48 V as per IEEE 802.3af/at

PoE Leistungsklasse Class 1 (0.44 to 3.84 Watt)

Communication interface

Number 1

Type 10 Base-T

Helmholz GmbH & Co. KG | Hannberger Weg 2 | 91091 Großenseebach | GermanyPhone +49 9135 7380-0 | Fax +49 9135 7380-110 | [email protected] | www.helmholz.de

Änderungen und Irrtümer vorbehalten. 03-2022

100 Base-TX

Transmission rate 10/100 Mbps autom. detection

Physical layer Ethernet

Protocol FDL, RFC 1006

Connection RJ45

MPI/PPI/PROFIBUS interface

Number 1

Type RS485, isolated

Transmission rate max. 12 Mbps autom. detection

Connection SUB-D male connector, 9-pin. with PG interface and repeater

Status indicator 3 LEDs, 2 of them bi-color

Voltage supply 24 V DC, 18–30 V DC

Current draw Max. 150 mA with DC 24 V

Ambient conditions

Ambient temperature 0 °C ... +60°C

Transport and storage temperature -20 °C … +80 °C

Relative air humidity 95 % r H without condensation

Pollution degree 2

Protection rating IP20

Certifications CE

CE

RoHS Yes

REACH Yes

Powered by TCPDF (www.tcpdf.org)