ROI-S05945-052E 060823 Network Configuration Toolj Operation Manual (Java version) NEC Corporation Copyright © 2006

Net Cfg Tool

Embed Size (px)

Citation preview

Page 1: Net Cfg Tool

ROI-S05945-052E 060823

Network Configuration Toolj

Operation Manual

(Java version)

NEC Corporation

Copyright © 2006

Page 2: Net Cfg Tool

ROI-S05945

- i -

TABLE OF CONTENTS

DOCUMENT WARRANTY................................................................................................................. 1

1 NETWORK CONFIGURATION TOOLJ .................................................................................... 2 1.1 PURPOSE ................................................................................................................................... 2 CONVENTIONS USED IN THIS MANUAL ................................................................................................ 2 1.2 DEFINITIONS, ACRONYMS AND ABBREVIATIONS ....................................................................... 3

2 NETCFG TOOLJ OPERATION .................................................................................................. 4 2.1 THE NETCFG TOOLJ SCREEN.................................................................................................... 4 2.2 NETCFG TOOLJ COMMAND MENU STRUCTURE ........................................................................ 5 2.3 STARTING NETCFG TOOLJ ........................................................................................................ 6 2.4 EXITING NETCFG TOOLJ........................................................................................................... 6 2.5 CREATING A NEW NETWORK CONFIGURATION WORKSPACE .................................................... 7 2.6 OPENING AN EXISTING WORKSPACE (*.NCT) ............................................................................ 7 2.7 NETWORK PROPERTIES: NAMING THE INDIVIDUAL NETWORKS IN A WORKSPACE ................... 8 2.8 NETWORK PROPERTIES: NETWORK ADDRESS AND SUBNET SETTING....................................... 8 2.9 EDITING WORKSPACE.............................................................................................................. 10

2.9.1 Adding a New Network Element (NE).......................................................................... 10 2.9.2 Adding Back-to-back Line (cable).................................................................................. 10 2.9.3 Back-to-Back Line Color Codes ..................................................................................... 11 2.9.4 Deleting a Network Element (NE) ................................................................................ 11 2.9.5 Deleting a Line (cable) ................................................................................................... 12 2.9.6 Setting or Modifying NE Properties of Pasolink V3, Pasolink V4 and Pasolink-S.... 12 2.9.7 Setting NE Properties of Pasolink Mx and Pasolink+.................................................. 19 2.9.8 Setting NE Properties of PASOLINK NEO.................................................................. 27 2.9.9 Setting Properties of MIU (Line Concentrator) ........................................................... 35 2.9.10 Setting Properties of MIU (Hop) ................................................................................... 43 2.9.11 Setting Line Properties.................................................................................................. 52

2.10 CREATING CONFIGURATION .................................................................................................... 54 2.11 CHANGED NE LIST.................................................................................................................. 56 2.12 VIEWING THE SUBNET INFORMATION ..................................................................................... 57 2.13 EXPORTING NETWORK CONFIGURATION FILES ...................................................................... 58

2.13.1 Exporting Network Configuration Files for PNMS ..................................................... 58 2.13.2 Exporting Network Configuration Files for PM Card ................................................. 59

2.14 SAVING CURRENT WORKSPACE............................................................................................... 61 2.15 PRINTING CURRENT NETWORK............................................................................................... 62 2.16 ABOUT NETWORK CONFIGURATION TOOLJ............................................................................. 63

3 MULTIPLE CPMC WORKSPACE............................................................................................ 64

APPENDIX A: MIU SETTINGS....................................................................................................... 66

APPENDIX B: SUBNETS................................................................................................................. 67

APPENDIX C: CONFIGURATION OF DUAL MASTER MIU ....................................................... 70

APPENDIX D: INCORRECT CONFIGURATION OF MIU (LINE CONCENTRATOR)............... 71

APPENDIX E: INCORRECT CONFIGURATION OF PASOLINK MX/PASOLINK+.................... 72

APPENDIX F: NMS PORT SETTING OF MIU (LINE CONCENTRATOR / HOP)....................... 74

Page 3: Net Cfg Tool

ROI-S05945

- 1-

Document Warranty

1. The information contained in this document is subject to change without prior notice.

2. The NetCfg Toolj screen figures in this manual are only examples. Screens will vary according to equipment configuration, operation modes, setting parameters, NetCfg Toolj application program version, etc. Screens contained in this manual are current at publication, however, they may differ from actual screens on your NetCfg Toolj

.

Page 4: Net Cfg Tool

ROI-S05945

- 2 -

1 Network Configuration Toolj

The Network Configuration Toolj (NetCfg Toolj) is an optional application tool for the Pasolink Network Management System, which provides an easy to use graphical interface in building NEC PASOLINK networks. It is a powerful tool used to generate configuration files for the Pasolink Management Cards (PMC) and network connection data files for the Pasolink Network Management System (PNMS).

1.1 Purpose

This document illustrates the use of the NetCfg Toolj. The explanation focuses on the common functions of the NetCfg Toolj and therefore is for general-purpose operational use. Moreover, the NEC PNMS is also briefly described to provide users with an overall understanding of the NEC PASOLINK NMS.

Conventions Used in this Manual Font What the Font Represents Example Italic For manual titles or related document

names. Please refer to Pasolink Operation Manual for details.

Hostname Bold

Items on the user interface. Items on the computer display. File and directory names.

The Overall window ...

[Button] Buttons on the user interface. Click on [OK] button to continue ... Click on [Execute] button to send command.

Menu Items A menu name followed by a colon (:) means that you must select the menu and then item. When the item is followed by an arrow ( ), a cascading menu follows.

Select System Login/Logout

Page 5: Net Cfg Tool

ROI-S05945

- 3 -

1.2 Definitions, Acronyms and Abbreviations

PNMS Pasolink Network Management System PNMT Pasolink Network Management Terminal PMC/CTRL Pasolink Management Card. (for Pasolink V3/Pasolink

V4/Pasolink-S/MIU only.) Control (CTRL) Module for PASOLINK NEO/Pasolink Mx/Pasolink+ only.

CPMC / CPM (for Pasolink V3/ Pasolink V4/Pasolink-S/MIU only) Root NE (for PASOLINK NEO/ Pasolink Mx/Pasolink+ only)

Central PMC/CTRL. The PMC/CTRL located on the central station's IDU and is directly connected to the PNMS. Acts as the master in the HDLC chain and is responsible for polling other PMC/CTRL in its network. A “C” symbol is displayed as part of CPM NE icon. An “R” symbol is displayed as part of the Root NE icon.

RPMC / RPM (for Pasolink V3/ Pasolink V4/Pasolink-S/MIU only) Normal NE (for PASOLINK NEO/ Pasolink Mx/Pasolink+ only)

Remote PMC/CTRL. The PMC/CTRL located on the remote sites that are configured as slaves.

SCPMC / SCPM (for Pasolink V3/Pasolink V4/

Pasolink-S/MIU only)

Branch NE (for PASOLINK NEO/ Pasolink Mx/Pasolink+ only)

Sub-Central PMC/CTRL. A PMC/CTRL located in the remote site and is configured as slave to the CPMC/Root NE but is a master to the sub-network below it. An “S” symbol is displayed as part of SCPM NE icon. A “B” symbol is displayed as part of Branch NE icon. Furthermore, A light blue “B” symbol indicates that no further subnet group can be spawned from this subnet group, while a yellow “B” symbol indicates otherwise.

NE Network Element. Node. ODU Outdoor Unit IDU Indoor Unit HDLC High-level Data Link Control protocol DSC Digital Service Channel PPP Point to Point Protocol SNTP Simple Network Time Protocol

Page 6: Net Cfg Tool

ROI-S05945

- 4 -

2 NetCfg Toolj Operation

2.1 The NetCfg Toolj Screen

The NetCfg Toolj window is composed of the following main areas (Refer to Figure 1).

Title Bar The title bar is used to indicate the title of the window. Common Menu Bar The common menu bar of the window presents the System and Help options, and indicates which commands can be executed from among the various options. The Help function can also display a pdf version of this operation manual. One Touch Expandable Button / Divider Initially the PNMT screen is split evenly to display the data from the two NE’s within a hop by using a divider. Click this button to move the divider to the edge of the window.

Title Bar

Common Menu Bar

Common Tool Bar

One Touch Expandable Button

Figure 1 Standard Components of NetCfg Toolj window

Total no. of NEs selected in the network

Total no. of NE

Network overview

Workspace

Divider

Page 7: Net Cfg Tool

ROI-S05945

- 5 -

2.2 NetCfg Toolj Command Menu Structure

Main Menu File Edit Network Tools Help

File New Open Save Save As Print Area Print Export Changed NE List Exit Application

Edit Undo Redo Copy Paste Delete Select All Select Add Network Element Add BB Line

Network New Copy Paste Delete Properties

Tools Create Configuration Subnet Information

Configuration Files for PM Card

Setting Clear

Pasolink V3 Pasolink V4 Pasolink Mx Pasolink-S MIU (LineConcentrator) MIU (HOP) Pasolink+ STM-1 Pasolink+ STM-0 Pasolink+ PDH PASOLINK NEO(HOP)

NetConfigToolj.pdf Help Help About NetConfigToolj

Page 8: Net Cfg Tool

ROI-S05945

- 6 -

2.3 Starting NetCfg Toolj

To start NetCfg Toolj:

1. Go to Start Programs NetCfg Toolj NetCfg Toolj from the Windows OS Start menu.

2. NetCfg Toolj main window will be displayed.

2.4 Exiting NetCfg Toolj

To exit the NetCfg Toolj application:

1. Go to File Exit Application in the main menu.

Page 9: Net Cfg Tool

ROI-S05945

- 7 -

2.5 Creating a New Network Configuration Workspace

To start creating new workspace:

1. Go to File New in the main menu.

2. A blank workspace will be displayed.

3. If a workspace is currently loaded, a pop-up message will appear to remind the user to save the current workspace before opening a new one. Click the [Cancel] button and save the current workspace and repeat step 1.

4. Start creating and editing network configuration workspace.

2.6 Opening an Existing Workspace (*.nct)

NetCfg Toolj allows you to save a workspace in *.nct file format so that you can open and modify the current network configuration. Once you load an existing/current workspace you will be able to modify, delete or add NE’s in the network. (See also 2.13 Saving Current Workspace.)

To open an existing workspace:

1. Click on File Open in the main menu of the main window.

2. Select the *.nct file of the workspace from the list.

3. Click [Open] button.

4. If a workspace is currently loaded, a pop-up message will appear to remind the user to save the current workspace before opening a new one. Click [Cancel] button and save the current workspace and repeat step 1.

5. Verify that the correct workspace is opened in the main window.

Page 10: Net Cfg Tool

ROI-S05945

- 8 -

2.7 Network Properties: Naming the Individual Networks in a Workspace

Since one workspace can contain a number of networks, the NetCfg Toolj allows you to provide useful names to each of the networks. By default, Network-x, where x is the network number, is assigned.

To set the network name:

1. Click on Network Properties from the main menu or right click anywhere in the current Network window to open the Network Properties window.

2. Enter the desired name for this workspace/network in the Network Name box.

3. Click on [OK] button to save the new setting.

2.8 Network Properties: Network Address and Subnet Setting

The IP addresses assigned by the NetCfg Toolj to selected network depend on the assigned Network Address and Subnet Mask in the Network Properties window. (Please refer to the PNMS Engineering Manual for the network-sizing rule and IP addressing scheme.)

To set the subnet of the selected network:

1. Click on Network Properties from the main menu or right click anywhere in the current Network window to open the Network Properties window.

2. Click on Subnet category in the Network Properties window.

3. By default the NetCfg Toolj will utilize the private network address 172.18.0.0 with subnet mask 255.255.254.0. This subnet allocates 512 IP addresses to the selected network. You can modify this subnet by selecting the default subnet and clicking the [Modify] button.

Where the network was initially assigned a smaller subnet, you can add another subnet when the IP address runs out. Click on [Add] button to assign a new subnet to the selected network. (NOTE: A maximum number of five network addresses and subnet mask settings is possible)

** For example, network address 10.10.10.0 with subnet mask 255.255.255.192 was initially assigned to the selected network. This means only 64 addresses are initially allocated. If the number of NE’s exceeds 62, a new subnet must be assigned to the network to allocate new IP addresses for the new NE’s

NOTE: The maximum number of NE’s per CPMC network is 416 NE’s regardless to whether more than 416 IP addresses are assigned to the network. (See PNMS Engineering Manual)

Page 11: Net Cfg Tool

ROI-S05945

- 9 -

The ensuing window, Network Address window, allows you to modify the default subnet by either changing the Network Address or the Subnet mask to be used by the selected network. You can increase or decrease the allocated IP address on the selected network by modifying the subnet mask and the network address in this window. (Refer to Appendix B: Subnets to see the available subnets in the managed network.)

In the example shown below, where the network address is 172.18.0.64 with subnet mask 255.255.255.192 given to the selected network, NetCfg Toolj will allocate the IP address 172.18.0.65-126 to this network. Note that in this example 62 IP addresses were assigned. Another as the network address (172.18.0.64) and another as the broadcast address (172.18.0.127). Click on [OK] to save the new subnet.

When the [Add] button was clicked in step.3, the ensuing window enables you to define another subnet that will be added to the existing subnet. Click on [Add] button to save the new subnet. (NOTE: The maximum number of network addresses and subnet mask settings that can be regstered is 5.)

4. Click on [OK] button to save the new settings.

Page 12: Net Cfg Tool

ROI-S05945

- 10 -

2.9 Editing Workspace

2.9.1 Adding a New Network Element (NE)

The NetCfg Toolj supports Pasolink V3, Pasolink V4, Pasolink-S, MIU, Pasolink Mx , Pasolink+ and PASOLINK NEO network configurations. Therefore a network element can either be a Pasolink V3, Pasolink V4, Pasolink S, MIU or Pasolink Mx, Pasolink+., PASOLINK NEO. Note that the configuration is the same for Pasolink-S, Pasolink V3 and Pasolink V4 or Pasolink Mx and Pasolink+.

To add a new NE:

1. Click on icon in the tool bar or click on Edit Network Element Type from the main menu to add a network element. Select the type of NE that you would like to add from the pull-down list. Pasolink V3 is selected by default.

2. Click on the spot in the current workspace where you wish to add the NE.

3. Arrange the newly added hop according to desired position in the workspace. The NEs can be moved around the workspace by clicking on it and dragging it to the desired location in the workspace

2.9.2 Adding Back-to-back Line (cable)

To add a back-to-back line (cable):

1. Click on the icon in the tool bar or click on Edit Add BB Line from the main menu.

2. Click on one of the NE to be connected. Then click on the other NE to be connected by back-to-back line (cable) to the previously selected NE. Refer to the example given below.

Example: Connecting Pasolink No.002 with Pasolink No.008

Step 1. Click on icon. Click on Pasolink No. 002.

Step 2. Click on Pasolink No. 008.

Note: Multi-drop or branch lines (B-B) cannot be connected to the output or the NMS signal source -No.001 in this example. PMC NMS port splits only the input signal but not the output signal. This is a limitation of the PMC hardware.

Step 3. Set the line properties. (Refer to 2.8.10 Setting Line (cable) Properties.)

Page 13: Net Cfg Tool

ROI-S05945

- 11 -

2.9.3 Back-to-Back Line Color Codes

The NMS back-to-back connection between NE’s varies according to the type of NE’s connected, speed, synchronization, the port used and the type of protocol used. The NetCfg Toolj uses color-coded lines to allow the network designer to distinguish the various types of connection.

The following lists the color codes used by the NetCfg Toolj to represent the different back-to-back connection types.

Black: represents the common RS-485/RS-232C/9600bps/ASYNC multi-drop line between Pasolink, Line Concentrator, MIU and Pasolink-S NE’s.

Red: represents the 64kbps/RS-422/SYNC connections between NE1 and NE1 of Pasolink Mx/Pasolink+ NE’s.

Violet: represents the RS485/19200bps/ASYNC connections NE2 and NE1 of Pasolink Mx/Pasolink+ NE’s or RS485/9600bps/ASYNC connection between Pasolink V3/PasolinkV4/Pasolink-S/MIU and PASOLINK NEO/Pasolink Mx/Pasolink+ NE’s or RS485/19200bps/ASYNC connection between PASOLINK NEO/Pasolink Mx/Pasolink+ and Pasolink V3/PasolinkV4/Pasolink-S/MIU NE’s.

Blue: represents the LAN (Ethernet) back-to-back connection between Pasolink Mx/Pasolink+ NE’s.

2.9.4 Deleting a Network Element (NE)

To remove an NE:

1. Click on the desired NE.

2. Right-click on the NE to display the context menu.

3. Click on Delete in the context menu to remove the NE.

Page 14: Net Cfg Tool

ROI-S05945

- 12 -

2.9.5 Deleting a Line (cable)

To remove a line:

1. Right click on the line to display the context menu.

2. Click on Line Delete in the context menu to continue removing the line.

2.9.6 Setting or Modifying NE Properties of Pasolink V3, Pasolink V4 and Pasolink-S

2.9.6.1 To set or modify NE properties of Pasolink V3, Pasolink V4 and Pasolink-S:

1. Right click on the selected NE to display the context menu. (Or double click on the selected NE to open the NE Properties window.)

2. Click on Properties in the context menu to open the NE Properties window.

3. By default, the NE Properties window opens with the General category view, which shows the current configuration.

4. In this window, Equipment Type, NE Name, Area Name, Note, PMC Type, NE Name Position, and Antenna Direction can be defined or modified. The definitions of these parameters are listed in Table 2.1.

Page 15: Net Cfg Tool

ROI-S05945

- 13 -

Table 2.1 General Parameters of Pasolink V3, Pasolink V4 and Pasolink-S

Parameter Definition Equipment Type Specifies the type of equipment of the target NE. (Pasolink V3 or

Pasolink V4 or Pasolink-S) Network Element Name Defines the name of the NE. Maximum number of characters

possible is 32. Area Name Defines the name of the area where the NE is located. (Optional).

Maximum number of characters possible is 32. Note Optional note used to describe the selected NE. Maximum number

of characters possible is 100. PMC Type Defines the role of the NE in the network. It can either be a CPM,

RPM or Sub-CPM Name Position Defines the position where the NE Name will be displayed in

relation to the NE bitmap in the workspace Antenna Direction Defines the direction where the NE is facing in the workspace.

2.9.6.2 Editing Network Parameters of Pasolink V3, Pasolink V4 and Pasolink-S

To change the Network Parameters of Pasolink V3, Pasolink V4 and Pasolink-S:

1. Right click on the selected NE to display the context menu. (Or double click on the selected NE to open the NE Properties window.)

2. Click on Properties in the context menu to open the NE Properties window.

3. The NE Properties window will appear. Click on Network category to display the Network Parameters window.

a) CPMC Network

4. In the ensuing window, the IP Address for DPU Port, Opposite NE IP Address, IP Address for NMS Port and Subnet Mask can be viewed. When “Assign IP Address manually” check box or “Assign Subnet Mask manually” check box is selected, user will be able to modify IP Addresses, Subnet Masks and Subnet Names of both DPU and NMS ports. The definitions of these parameters are listed in Table 2.2.

Page 16: Net Cfg Tool

ROI-S05945

- 14 -

b) SCPMC Network

Table 2.2 Network Parameters of Pasolink V3, Pasolink V4 and Pasolink-S

Parameter Definition Assign IP Address manually By selecting this check box you can change the IP

Address the DPU and NMS ports. Assign Subnet Mask manually By selecting this check box you can change Subnet Mask

of both DPU and NMS ports. IP Address Defines the assigned IP Address of the selected NE. Subnet Mask Defines which part of the PMC IP Address will be masked

and defined as subnet. This also, defines what class of IP addressing is used. (i.e. Class A, Class B, Class C, etc.). Only 3 subnet masks are allowed: 16 (255.255.255.240) default, 8 (255.255.255.248) or 4 (255.255.255.252).

Subnet Name Defines the name of the DPU Port sub-network.

DPU Port

Opposite Network Element

Defines the IP Address of the opposite station

IP Address Defines the assigned IP Address of the selected NE. Subnet Mask Defines which part of the PMC IP Address will be masked

and defined as subnet. This also, defines what class of IP addressing is used. (i.e. Class A, Class B, Class C, etc.). Only 3 subnet masks are allowed: 16 (255.255.255.240) default, 8 (255.255.255.248) or 4 (255.255.255.252).

NMS Port

Subnet Name Defines the name of the NMS Port sub-network.

Page 17: Net Cfg Tool

ROI-S05945

- 15 -

2.9.6.3 Editing Port Configuration Parameters of Pasolink V3, Pasolink V4 and Pasolink-S

To change the Port Configuration Parameters of Pasolink V3, Pasolink V4 and Pasolink-S:

1. Right click on the selected NE to display the context menu. (Or double click on the selected NE to open the NE Properties window.)

2. Click on Properties in the context menu to open the NE Properties window.

3. The NE Properties window will appear. Click on Port category to display the Port Configuration Parameters window.

4. The DPU Port and NMS Port baud rates can be changed via this window. The definitions of these parameters are listed in Table 2.3.

Table 2.3 Port Configuration Parameters of Pasolink V3, Pasolink V4 and Pasolink-S

Parameter Definition Action Mode

Defines the role of the DPU Port of NE. * The possible modes are Master, Slave, and Repeater.

DPU Port

Baud Rate Defines the speed of the DPU Port in bits-per-second (bps).Action Mode Defines the role of the NMS Port of NE. * The possible

modes are Master, Slave, Repeater and Disabled. Baud Rate Defines the speed of the NMS Port in bits-per-second (bps).

NMS Port

Mode Defines the wiring (interface) protocol used * This item will not be defined until the Create Configuration process.

Page 18: Net Cfg Tool

ROI-S05945

- 16 -

2.9.6.4 Editing HDLC Configuration Parameters of Pasolink V3, Pasolink V4 and Pasolink-S

To change the HDLC Configuration Parameters of Pasolink V3, Pasolink V4 and Pasolink-S:

1. Right click on the selected NE to display the context menu. (Or double click on the selected NE to open the NE Properties window.)

2. Click on Properties in the context menu to open the NE Properties window.

3. The NE Properties window will appear. Click on HDLC category to display the HDLC Configuration Parameters window.

4. In this window, the Master Timeout, Master Interval, Slave Timeout, Auto Roll Change, Roll Change and High BER DPU Inhibit can be defined and changed. The definitions of these parameters are listed in Table 2.4.

Table 2.4 HDLC Configuration Parameters of Pasolink V3, Pasolink V4 and Pasolink-S

Parameter Definition Master Timeout The time in seconds after which the PMC will assume that it has lost the

communication link with the master PMC. Master Interval The interval in seconds at which the PMC will check for the polling

signal from the master PMC Slave Timeout The time in seconds after which the master PMC will assume that the

link with its slave PMC is lost. Auto Role Change If enabled, the PMC will automatically change its role from slave to

master PMC, once it has lost its link with the master PMC in the upper network. It will also automatically change back to slave once the link with the master is restored. This is normally set to "Enable".

Role Change Timeout The elapsed time in seconds that the slave PM card waits for the polling message from the CPMC before it changes itself to assume the role of the CPMC.

High BER DPU Inhibit If High BER DPU Inhibit is set to Enable, Hi BER alarm is inhibited. Then it will not be activated even if DPU port receives deficient data.

Page 19: Net Cfg Tool

ROI-S05945

- 17 -

2.9.6.5 Editing Other Parameters of Pasolink V3, Pasolink V4 and Pasolink-S

To change the Other Parameters of Pasolink V3, Pasolink V4 and Pasolink-S:

1. Right click on the selected NE to display the context menu. (Or double click on the selected NE to open the NE Properties window.)

2. Click on Properties in the context menu to open the NE Properties window.

3. The NE Properties window will appear. Click on Other category to display the Other Parameters window.

4. In this window, the Auto Set Time, Set Time Interval, Auto Write Back, and Write Back Interval can be changed. The definitions of these parameters are listed in Table 2.5.

Table 2.5 Other Parameters of Pasolink V3, Pasolink V4 and Pasolink-S

Parameter Definition Auto Set Time If enabled, the PMC automatically sets its time to match that of the

PNMS or the CPMC. Set Time Interval The time interval before the PMC periodically synchronizes its

time to the PNMS or CPMC. Auto Write Back If enabled, the PMC automatically writes the Log data and PM

data to the Flash ROM. Write Back Interval The time interval at which the PMC saves Log and PM data in the

Flash ROM.

Page 20: Net Cfg Tool

ROI-S05945

- 18 -

2.9.6.6 Editing PNMS Parameters (for CPMC only) of Pasolink V3, Pasolink V4 and Pasolink-S

This parameter is relevant only to the NE designated as CPMC.

To change the PNMS Parameters of Pasolink V3, Pasolink V4 and Pasolink-S:

1. Right click on the selected NE to display the context menu. (Or double click on the selected NE to open the NE Properties window.)

2. Click on Properties in the context menu to open the NE Properties window.

3. The NE Properties window will appear. Click on PNMS category to display the PNMS Parameters window.

4. In this window, the IP address and subnet mask information of the PNMS port are

defined. LAN or RS232/RS422 is selected as the connection mode and the corresponding parameters in the ensuing box are activated. These parameters are defined in Table 2.6.

Page 21: Net Cfg Tool

ROI-S05945

- 19 -

Table 2.6 PNMS Parameters of Pasolink V3, Pasolink V4 and Pasolink-S

Parameter Definition PNMS Connection Defines the type of connection used by the CPMC to the

PNMS. The CPMC can connect to the PNMS PC / Workstation either thru RS232C/RS422 (Dial-Up) or LAN (IP) connection. Pasolink V3, Pasolink V4: RS232C/RS422/LAN Pasolink-S: RS232C/RS422

IP Address IP address of LAN port of the target NE. Subnet Mask Subnet mask of LAN port mentioned above.

LAN

Default Gateway IP address of Default Gateway. Normally the IP address of the PNMS PC.

Connection Type Defines the type of connection used by the CPMC to the PNMS. The CPMC can connect to the PNMS PC either thru Direct connection (Dial-Up) or Router connection.

IP Address When the RS232C or RS422 PNMS connection is selected, the input fields are activated. The IP address is the one that is used by the RS232C or RS422 port of the Pasolink IDU.

RS232C/RS422

Subnet Mask Subnet Mask of the RS232C or RS422 port mentioned above.

2.9.7 Setting NE Properties of Pasolink Mx and Pasolink+

2.9.7.1 To set or modify the NE properties of Pasolink Mx/Pasolink+:

1. Right click on the selected NE to display the context menu (Or double click on the selected NE to open the NE Properties window.)

2. Click on Properties in the context menu to open the NE Properties window.

3. The NE Properties window will be displayed as shown below. The default view is the General category window, which shows the current configuration.

4. In this window, NE Name, Area Name, Note, CTRL Type, NE Name Position, and Antenna Direction can be changed. These parameters are defined in Table 2.7.

Page 22: Net Cfg Tool

ROI-S05945

- 20 -

Table 2.7 General Parameters of Pasolink Mx and Pasolink+

Parameter Definition Equipment Type The type of equipment: Pasolink Mx, Pasolink+ STM-1,

STM-0 and PDH. Network Element Name

The name of the NE in the network. Maximum number of characters possible is 32.

Area Name The area where the NE is located (optional). Maximum number of characters possible is 80.

System

Note Additional description, or remark on the NE (optional). Maximum number of characters possible is 100.

CTRL Type CTRL Type Role of the CTRL in the network. Root NE, Branch NE or Normal NE.

Name Position The position of the text in the workspace can be customized here.

Position/ Direction

Antenna Direction

The antenna icon in the workspace can be customized to face either Right or Left.

Port Information This provides the IP information of the available port in the selected NE. The IP address that the port uses and its subnet mask can be viewed in this section.

Page 23: Net Cfg Tool

ROI-S05945

- 21 -

2.9.7.2 Editing Radio/NE1 Parameters of Pasolink Mx and Pasolink+

To change the Radio/NE1 Parameters of Pasolink Mx and Pasolink+:

1. Right click on the selected NE to display the context menu. (Or double click on the selected NE to open the NE Properties window.)

2. Click on Properties in the context menu to open the NE Properties window.

3. The NE Properties window will appear. Click on the Radio/NE1 category to display the Radio/NE1 port information.

a) Root NE / Normal NE b) Branch NE

4. In this window, the IP Address information of the Radio/NE1 port is defined. If the CTRL

Type from the General category is set to “Root NE” or “Normal NE”, the IP address under “Bridge” is used. On the other hand, if “Branch NE” is set, the IP addresses under “Separate Interface” are used. The definitions of these parameters are listed in Table 2.8.

NOTE: The IP addresses, Subnet Masks can only be manually set if selected in “Assign IP Address manually” check box or “Assign Subnet Mask manually” check box.

Page 24: Net Cfg Tool

ROI-S05945

- 22 -

Table 2.8 Radio/NE1 Parameters of Pasolink Mx and Pasolink+

Parameter Definition Assign IP Address manually When “Assign IP Address manually” check box is

selected, user can modify IP Address (Radio/NE1). Assign Subnet Mask manually When “Assign Subnet Mask manually” check box is

selected, user can modify Subnet Mask (Radio/NE1). Bridge IP Address IP address of the Bridge or LAN port of the selected

NE Bridge Subnet Mask Subnet mask of the LAN port Bridge Subnet Name Defines the name of the Bridge Port sub-network. IP Address for Radio IP address of the DPU/Radio port. Subnet Mask for Radio Subnet mask of the DPU/Radio port Subnet Name for Radio Defines the name of the Radio port sub-network. IP Address for NE1 IP address of NE1 port Subnet Mask for NE1 Subnet mask of NE1 port

Network

Subnet Name for NE1 Defines the name of the NE1 port sub-network. Radio /Speed Speed of the DPU port of the selected NE Radio /Opposite IP Address

IP address of the opposite NE (DPU port).

NE1 /Speed Speed of the NE1 port of the target NE

Port Setting

NE1 /Mode The HDLC mode of NE1 port. Enabled only when NE1 (64000 bps is used). The possible modes are Master, Slave and Disabled.

2.9.7.3 Editing NE2 Parameters of Pasolink Mx and Pasolink+

To change the NE2 Parameters for Pasolink Mx and Pasolink+:

1. Right click on the selected NE to display the context menu. (Or double click on the selected NE to open the NE Properties window.)

2. Click on Properties in the context menu to open the NE Properties window.

3. The NE Properties window will appear. Click on the NE2 category to display the NE2 port information.

4. In this window, the IP Address of the NE2 port is defined. The definitions of these parameters are listed in Table 2.9.

Page 25: Net Cfg Tool

ROI-S05945

- 23 -

Table 2.9 NE2 Parameters of Pasolink Mx and Pasolink+

Parameter Definition Data Link Type of data link protocol used by NE2. This is always set

at HDLC when connected in multi-drop with another NE. The data link will be set to PPP when connected to a Pasolink V3/Pasolink V4/Pasolink-S/MIU CPMC.

IP Address IP address of NE2. Subnet Mask Subnet mask of NE2 port.

Common

Speed Speed of NE2 port. Mode Specifies if the NE2 port is used in HDLC. The NE2 port

can either be Master, Slave or blank. Terminal Auto Assign

Automatically allow the NetCfg Toolj to terminate the HDLC connection of the selected NE’s NE2 port, if it is the last port in the HDLC line. (Recommended)

HDLC

Terminate If “Terminal Auto Assign” is set to Manual, the NE2 port termination can be set to On or Off.

2.9.7.4 Editing LAN (B-B) Parameters of Pasolink Mx and Pasolink+

To change the LAN (B-B) Parameters of Pasolink Mx and Pasolink+:

1. Right click on the selected NE to display the context menu. (Or double click on the selected NE to open the NE Properties window.)

2. Click on Properties to open the NE Properties window.

3. The NE Properties window will appear. Click on the LAN (B-B) category to display the LAN (B-B) parameters.

4. The IP address and Subnet Mask of the LAN port are defined in this window. It is shown only if the back to back connection is set to LAN.

Page 26: Net Cfg Tool

ROI-S05945

- 24 -

2.9.7.5 Editing PNMS Parameters (for Root NE only) of Pasolink Mx and Pasolink+

This parameter is relevant only to NE designated as Root NE.

To change the PNMS Parameters:

1. Right click on the selected NE to display the context menu. (Or double click on the selected NE to open the NE Properties window.)

2. Click on Properties in the context menu to open the NE Properties window.

3. The NE Properties window will appear. Click on the PNMS category to display the PNMS parameters.

4. In this window, the IP Address and subnet mask information of the PNMS port are defined. The definitions of these parameters are listed in Table 2.10.

Table 2.10 PNMS Parameters of Pasolink Mx and Pasolink+

Parameter Definition PNMS Connection Defines the type of connection to the PNMS used by

the Root NE. The Root NE can connect to the PNMS PC either thru V.11 (Dial-UP) connection or LAN (IP) connection.

IP Address When the Ethernet connection is selected, the LAN input fields are activated. The IP address defines that it is used by the IDU LAN port. However, it is only used when the LAN port is used for connecting the PNMS IP address of LAN port of the NE. This is only set if the selected NE is a Root NE.

LAN

Subnet Mask Subnet mask of abovementioned LAN port . IP Address When the Dial-Up connection is selected, the V.11

input fields are activated. The IP address defines that it is used by the V.11 port of the IDU. Note that is only used when the V.11 port is used for PNMS connection.

Subnet Mask Subnet Mask of the V.11 port mentioned above.

V.11 (Default)

Speed Connection speed for dial-up access.

Page 27: Net Cfg Tool

ROI-S05945

- 25 -

2.9.7.6 Editing Routing Parameters of Pasolink Mx and Pasolink+

To change the Routing Parameters of Pasolink Mx and Pasolink+:

1. Right click on the selected NE to display the context menu. (Or double click on the selected NE to open the NE Properties window.)

2. Click on Properties to open the NE Properties window.

3. The NE Properties window will appear. Click on the Routing category to display the routing parameters.

4. The IP address of the Default Gateway can be set via this window. The Default Gateway IP address is normally the IP address of the PNMS PC / Workstation or the router associated with the PNMS.

2.9.7.7 Editing SNTP Parameters of Pasolink Mx and Pasolink+

Each NE support Simple Network Time Protocol, used to synchronize its internal clock to a defined Time-server in the network.

To change the SNTP Parameters for Pasolink Mx and Pasolink+:

1. Right click on the selected NE to display the context menu. (Or double click on the selected NE to open the NE Properties window.)

2. Click on Properties to open the NE Properties window.

3. The NE Properties window will appear. Click on the SNTP category to display the SNTP parameters.

Page 28: Net Cfg Tool

ROI-S05945

- 26 -

a) Root NE b) Other

4. The Time Synchronization mode can be set in this window. The time on the CRTL

module can either be synchronized to a time-server with SNTP in the network or set to None or no time synchronization. The IP address of the time-server as well as the Refresh Interval- (the time in seconds that has elapsed before the NE will try to synchronize its internal clock to a specified time-server) can be set in this window.

Page 29: Net Cfg Tool

ROI-S05945

- 27 -

2.9.8 Setting NE Properties of PASOLINK NEO

2.9.8.1 To set or modify the NE properties of PASOLINK NEO:

1. Right click on the selected NE to display the context menu (Or double click on the selected NE to open the NE Properties window.)

2. Click on Properties in the context menu to open the NE Properties window.

3. The NE Properties window will be displayed as shown below. The default is the General category window, which shows the current configuration.

4. In this window, NE Name, Area Name, Note, CTRL Type, Branch NE Type, NE Name Position, and Antenna Direction can be changed. The definitions of these parameters are listed in Table 2.11.

Table 2.11 General Parameters of PASOLINK NEO

Parameter Definition Equipment Type The type of equipment: PASOLINK NEO

Network Element Name

The name of the NE in the network. Maximum number of characters possible is 32.

Area Name The area where the NE is located (optional). Maximum number of characters possible is 80.

System

Note Additional description, or remarks on the NE (optional). Maximum number of characters possible is 100.

CTRL Type Role of the CTRL in the network. Root NE, Root NE (Bridge), Branch NE or Normal NE.

CTRL Type

Branch NE Type The number of Branch NEs: None,, 2, or 3 branches.

Name Position The position of the text in the workspace can be customized here.

Position/ Direction

Antenna Direction

The antenna icon in the workspace can be customized to face either Right or Left.

Port Information This provides the IP information of the available port in the selected NE. The IP address that the port uses and its subnet mask can be viewed in this section.

Page 30: Net Cfg Tool

ROI-S05945

- 28 -

2.9.8.2 Editing each Port Parameters of PASOLINK NEO

The Port category displayed in the Network overview changes according to the type of CTRL and Branch NE that is selected.

To change the respective Port Parameters for PASOLINK NEO:

1. Right click on the selected NE to display the context menu. (Or double click on the selected NE to open the NE Properties window.)

2. Click on Properties in the context menu to open the NE Properties window.

3. The NE Properties window will appear. Click on the respective Port category to display the corresponding port information. (Note: EM2(NE) Port, EM1(NMS) Port )

a) Radio/EM2 Port b) Radio/EM2/EM1 Port (Bridge) ---- Root NE --- Normal NE, Root Branch NE(No branch)

c) EM2/EM1 Port / Radio Port d) EM2 Port / Radio/EM1 Port --- Branch NE(2Brances) --- Branch NE(2Branches)

Port category Port category

Port category Port category

Page 31: Net Cfg Tool

ROI-S05945

- 29 -

e) Radio Port / EM2 Port / EM1 Port --- Branch NE (3Branches)

4. In this window, the IP Address for the respective port is defined. These parameters are defined in Table 2.12.

NOTE: The IP addresses, Subnet Masks can only be manually set if selected in the “Assign IP Address manually” or “Assign Subnet Mask manually” check box.

Table 2.12 Port Parameters of PASOLINK NEO

Parameter Definition Assign IP Address manually When “Assign IP Address manually” check box is

selected, user can modify IP Address. Assign Subnet Mask manually When “Assign Subnet Mask manually” check box is

selected, user can modify Subnet Mask. Primary When the “Primary” check box of a port is selected,

that port’s IP address becomes detectable by the PNMS.

IP Address IP address of the respective port. Subnet Mask Subnet mask of the respective port.

Network

Subnet Name Defines the name of the respective port sub-network.

Page 32: Net Cfg Tool

ROI-S05945

- 30 -

2.9.8.3 Editing Async Parameters of PASOLINK NEO

Whenever a PASOLINK NEO is connected via Async to another device (whether it is another PASOLINK NEO or not), the Async category is displayed in the Network overview.

To change the Async Parameters of PASOLINK NEO:

1. Right click on the selected NE to display the context menu. (Or double click on the selected NE to open the NE Properties window.)

2. Click on Properties in the context menu to open the NE Properties window.

3. The NE Properties window will appear. Click on the Async category to display the Async port information.

4. In this window, the IP Address of the Async port is defined. The definitions of these parameters are listed in Table 2.13.

Table 2.13 Async Parameters of PASOLINK NEO

Parameter Definition Data Link Type of data link protocol used by Async. This is always

set at HDLC when connected in multi-drop with another NE. The data link will be set to PPP when connected to a Pasolink V3/Pasolink V4/Pasolink-S/MIU CPMC.

IP Address IP address of Async port. Subnet Mask Subnet mask of Async port.

Common

Speed Speed of Async port. Mode Specifies if the Async port is used in HDLC. The Async

port can either be Master, Slave or blank. Terminal Auto Assign

Automatically allow the NetCfg Toolj to terminate the HDLC connection of the selected NE’s Async port, if it is the last port in the HDLC line. (Recommended)

HDLC

Terminate If “Terminal Auto Assign” is set to Manual, the Async port termination can be set to On or Off.

Page 33: Net Cfg Tool

ROI-S05945

- 31 -

2.9.8.4 Editing PNMS(EM1) Parameters (for Root NE only) of PASOLINK NEO

When Root NE is selected as the CTRL Type, the PNMS(EM1) category is displayed in the Network

overview.

To change the PNMS(EM1) Parameters:

1. Right click on the selected NE to display the context menu. (Or double click on the selected NE to open the NE Properties window.)

2. Click on Properties in the context menu to open the NE Properties window.

3. The NE Properties window will appear. Click on the PNMS (EM1) category to display the PNMS(EM1) parameters.

4. In this window, the IP Address and subnet mask and default gateway information of the PNMS(EM1) port are defined. The definitions of these parameters are listed in Table 2.14.

Table 2.14 PNMS(EM1) Parameters of PASOLINK NEO

Parameter Definition IP Address The IP address defines that it is used by the IDU

EM1(NMS) port. However, it is only used when the EM1(NMS) port is used for connecting the PNMS IP address. This is only set if the selected NE is a Root NE.

Subnet Mask Subnet mask of above mentioned EM1(NMS) port .

NMS

Default Gateway

Default Gateway of above mentioned EM1(NMS) port .Normally the IP address of the PNMS PC / Workstation or the router associated with the PNMS.

Page 34: Net Cfg Tool

ROI-S05945

- 32 -

2.9.8.5 Editing Routing Parameters of PASOLINK NEO

To indicate the Routing Parameters of PASOLINK NEO:

1. Right click on the selected NE to display the context menu. (Or double click on the selected NE to open the NE Properties window.)

2. Click on Properties to open the NE Properties window.

3. The NE Properties window will appear. Click on the Routing category to display the routing parameters.

4. The IP address of the Default Gateway can be indicated via this window. The Default Gateway IP address of Root NE is normally the IP address of the PNMS PC / Workstation or the router associated with the PNMS. The first subnet IP address is automatically set as the Default Gateway IP address for Branch /Normal NEs.

2.9.8.6 Editing SNTP Parameters of PASOLINK NEO

Each NE support Simple Network Time Protocol, used to synchronize its internal clock to a defined Time-server in the network.

To change the SNTP Parameters of PASOLINK NEO:

1. Right click on the selected NE to display the context menu. (Or double click on the selected NE to open the NE Properties window.)

2. Click on Properties to open the NE Properties window.

3. The NE Properties window will appear. Click on the SNTP category to display the SNTP parameters.

Page 35: Net Cfg Tool

ROI-S05945

- 33 -

a) Root NE, Root NE (Bridge) b) Other

4. The Time Synchronization mode can be set in this window. The time on the CRTL

module can either be synchronized to a time-server with SNTP in the network or set to None or no time synchronization. The IP address of the time-server as well as the Refresh Interval (the time in seconds that has elapsed before the NE will try to synchronize its internal clock to a specified time-server) can be set in this window.

Page 36: Net Cfg Tool

ROI-S05945

- 34 -

2.9.8.7 Editing IP Restriction Parameters (for Root NE [Bridge] only) of PASOLINK NEO

In network configurations where the Subnet is not supposed to be disconnected at the Root NE, IP addresses can be preset for devices connected ahead of the Root NE in the IP Restriction Category window (for instance: IP addresses for the PNMS computer or the router). When configuring (Create Configuration) with NetCfg Toolj, IP addresses (apart from any preregistered ones) are automatically assigned to other devices. When Root NE (Bridge) is selected as the CTRL Type, the IP Restriction category is displayed in the Network overview.

To set the IP Restriction Parameters of PASOLINK NEO:

1. Right click on the selected NE to display the context menu. (Or double click on the selected NE to open the NE Properties window.)

2. Click on Properties to open the NE Properties window.

3. The NE Properties window will appear. Click on the IP Restriction category to display the IP Restriction parameters.

4. To preset/register IP Addresses, use the Add/Modify/Remove buttons under Restricted IP Address for top subnet. (If no IP addresses need to be preset, simply proceed to the next step).

5. Under Default Gateway for the Root NE (Bridge), input the IP Address of the Default Gateway for the Root NE (Bridge).

No.01 No.02 No.03 No.04

PNMS Root NE (Bridge)

Normal NE Normal NE Normal NE

No.01 No.02 No.03 No.04

PNMS Root NE (Bridge)

Normal NE Normal NE Normal NE Router

Subnet

Page 37: Net Cfg Tool

ROI-S05945

- 35 -

2.9.9 Setting Properties of MIU (Line Concentrator)

A Line Concentrator is a Stand-alone MIU that is used as a CPMC to poll other NE’s in its sub-network

To modify the properties of MIU (Line Concentrator):

1. Right click on the selected MIU (Line Concentrator) to display the context menu. (Or double click on the selected MIU to open the Properties window of the selected Line Concentrator.)

2. Click on Properties in the context menu to open the Properties window of the selected Line Concentrator.

3. The Properties window of the Line Concentrator contains the parameters shown and defined in Table 2.15.

4. Click on [OK] button after completing the Line concentrator properties setup.

Page 38: Net Cfg Tool

ROI-S05945

- 36 -

Table 2.15 Properties of MIU (Line Concentrator)

Parameter Definition Equipment In Line Concentrator this field will display “Line

Concentrator” and will not be selectable (appears gray). Redundancy Not Applicable. Total PMC The total number of PMC’s needed to monitor the

selected equipment. NOTE: In case of Line concentrator, ONLY 1 PMC is possible. DO NOT set the Total PMC to a value greater than 1.

Type Not Applicable. Repeater Type Not Applicable. Bit Rate ID Not Applicable.

System

FASYNC Alarm Active

Not Applicable.

Name The name that will be associated with the selected Line concentrator symbol. Maximum number of characters possible is 29. NOTE: This is the primary name NE in the workspace. This name will NOT be associated to the configuration file for this NE. To set the name for the configuration file see section 2.9.9.1) Editing General Parameters of MIU (Line Concentrator), Table 2.16)

Name Position The position where the name of the selected Line concentrator will be displayed.

Symbol

Line Direction Defines on which side the NMS line will be added to the Line concentrator.

MIU CPMC Normal This button contains the NE properties of the Line concentrator. This contains the network, HDLC, port and other parameters connected to the NMS setting of the MIU. (See Appendix A: MIU Setting)

2.9.9.1 Setting NE Properties of MIU (Line Concentrator)

1) To set or edit General Parameters of MIU (Line Concentrator)

To set/change the General Configuration Parameters of MIU (Line Concentrator):

1. Right click on the selected Line Concentrator to display the context menu. (Or double click on the selected MIU to open the Properties window.)

2. Click on Properties from the context menu to open the Properties window of Line Concentrator.

3. Click on [CPMC Normal] button on the Properties window.

Page 39: Net Cfg Tool

ROI-S05945

- 37 -

4. The NE Properties window will appear. The default is the General category window, which shows the current configuration. The [Cancel] button will close the window without saving the changes.

5. In this window, the NE Name, Area Name, Note, Equipment Type and A/D Convert Type can be changed. The definitions of these parameters are listed in Table 2.16.

Table 2.16 General Parameters of MIU (Line Concentrator)

Parameter Definition NE Name The name that will be associated with the target NE.

This name will be applied in the configuration files. Maximum number of characters possible is 32.

Area Name The area where the NE is located (optional). Maximum number of characters possible is 32.

Note Additional description of the NE (optional). Maximum number of characters possible is 100.

PMC Usage Not Available Equipment Type Displayed as Line Concentrator (not selectable). Performance Monitor Input

Not Available.

System

A/D Convert Type The number of Analog-to-Digital conversions used in the MIU. The MIU is capable of processing a maximum of two (2) A/D conversions.

PMC Type Set as CPMC for line concentrators – cannot be modified.

2) Editing Network Parameters of MIU (Line Concentrator)

(Refer to 2.9.6.2 Editing Network Parameters of Pasolink V3, Pasolink V4 and Pasolink-S.)

Page 40: Net Cfg Tool

ROI-S05945

- 38 -

3) Editing HDLC Parameters of MIU (Line Concentrator)

To change the HDLC configuration parameters:

1. Right click on the selected Line concentrator to display the context menu. (Or double click on the selected MIU to open the Properties window.)

2. Click on Properties in the context menu to open the Properties window.

3. Click on [CPMC Normal] button on the Properties window

4. The NE Properties window will appear. Select HDLC category in the NE Properties window.

5. The HDLC parameters window contains the parameters concerning the HDLC settings of the target Line Concentrator. Note that the HDLC default values are the optimum (recommended) settings. The definition of the HDLC parameters is shown in Table 2.17.

Table 2.17 HDLC Parameters of MIU (Line Concentrator)

Parameter Definition Master Timeout The time in seconds after which the PMC will assume

that it has lost the communication link with the master PMC.

Master Interval The interval in seconds at which the PMC will check for the polling signal from the master PMC

HDLC Timer

Slave Timeout The time in seconds after which the master PMC will assume that the link with its slave PMC is lost.

Auto Role Change If enabled, the PMC will automatically change its role from slave to master PMC, once it has lost its link with the master PMC in the upper network. It will also automatically change back to slave once the link with the master is restored. This is normally set to "Enable".

Role Change

Role Change Timeout

The elapsed time in seconds that the slave PM card waits for the polling message from the CPMC before it changes over to assume the role of the CPMC.

HDLC Relay High BER DPU Inhibit

If High BER DPU Inhibit is set to Enable, Hi BER alarm is inhibited. This means that it will not be activated even if the DPU port receives degraded data.

Page 41: Net Cfg Tool

ROI-S05945

- 39 -

4) Editing Port Parameters of MIU (Line Concentrator)

To change the Port configuration parameters:

1. Right click on the selected Line Concentrator to display the context menu. (Or double click on the selected MIU to open the Properties window.)

2. Click on Properties in the context menu to open the Properties window.

3. Click on [CPMC Normal] button on the Properties window.

4. The MIU’s NE Properties window will appear.

5. Select the Port category. The Port category window contains the parameters defining the port settings of the target Line Concentrator. The definition of the Port parameters is shown in Table 2.18.

Table 2.18 Port Parameters of MIU (Line Concentrator)

Parameters Definition Action Mode Defines the role of the DPU Port of MIU.

Disabled for Line Concentrator. Baud Rate Not applicable.

DPU Port*

Mode Not applicable. Action Mode Defines the role of the NMS Port of MIU.

Set to Master for Line concentrators. Baud Rate Defines the speed of the NMS Port in bits-per-second

(bps). Mode Auto Assign If Mode Auto Assign is set to Manual, the mode on the

NMS port can be set to RS485_TX or RS485_RX. Mode Defines the wiring (interface) protocol used Terminal Auto Assign Automatically allow the NetCfg Toolj to terminate the

HDLC connection of the selected NE’s NMS port, if it is the last port in the HDLC line. (Recommended)

NMS Port

Terminate If Terminal Auto Assign is set to Manual, the termination on the NMS port can be set to Enable or Disable. Terminates the RS485 protocol line when enabled.

Page 42: Net Cfg Tool

ROI-S05945

- 40 -

5) Other Parameters of MIU (Line Concentrator)

To change the Other Parameters of MIU (Line Concentrator):

1. Right click on the selected Line Concentrator to display the context menu. (Or double click on the selected MIU to open the Properties window.)

2. Click on Properties in the context menu to open the MIU Properties window.

3. Click on [CPMC Normal] button of the Properties window.

4. The Line Concentrator’s NE Properties window will appear.

5. Select the Other category. The Other category window contains the parameters defining the Time and Flash ROM settings of the target Line Concentrator. The definition of the Other parameters is shown in Table 2.19.

Table 2.19 Other Parameters of MIU (Line Concentrator)

Parameter Definition Auto Set Time If enabled, the PMC automatically synchronizes its

time to that of the PNMS or the CPMC. Set Time

Set Time Interval The time interval before the PMC periodically synchronizes its time to that of the PNMS or CPMC.

Auto Write Back If enabled, the PMC automatically writes the Log data and PM data to the Flash ROM.

Flash ROM

Write Back Interval The time interval before the PMC writes the Log data and PM data to the Flash ROM.

6) Editing PNMS Parameters of MIU (Line Concentrator)

To change the PNMS configuration parameters of MIU (Line Concentrator):

1. Right click on the selected MIU to display the context menu. (Or double click on the selected MIU to open the Properties window.)

2. Click on [CPMC Normal] button in the Properties window.

Page 43: Net Cfg Tool

ROI-S05945

- 41 -

3. The Line Concentrator’s NE Properties window will appear. The default is the General category window, which shows the current configuration.

4. Select the PNMS category window, which contains the parameters defining the PNMS connection type, IP address, subnet mask, default gateway and other network parameters of the Line concentrator. When LAN or RS232/RS422 connections are selected, the corresponding parameters in the ensuing box are activated. Table 2.20.shows PNMS port parameters.

Page 44: Net Cfg Tool

ROI-S05945

- 42 -

Table 2.20 PNMS Parameters of MIU (Line Concentrator)

Parameter Definition PNMS Connection Defines the type of connection that the PMC in the Line

concentrator has the PNMS. There are three (3) possible PNMS connections allowed by the PMC namely: RS-232C: PNMS connects to the PMC using RS-232C/19.2kbps Asynchronous interface. RS-422: PNMS connects to the PMC using RS422/19.2kbps/V.11 Asynchronous Interface LAN: PMC connects directly to an Ethernet network using 10BaseT/10Mbps interface.

IP Address Defines the IP address that will be assigned to the LAN-PNMS port of the PMC.

Subnet Mask Defines the subnet mask used by the LAN port of the PMC.

LAN*

Default Gateway

Defines the IP address where of the machine where the traps from the PMC will be forwarded. In cases where the PNMS PC/WS is in the same network (LAN) as the PMC, this will normally be the IP address of the PNMS PC/WS. In case of WAN or networks wherein the PNMS is located in another network, this will be the IP address of the nearest router.

Connection Type

Specifies whether the RS232C/RS422 connection is Direct or through Router. Direct - connection means the PNMS PC connects to the CPMC using its local COM ports. Router – means that the CPMC is connected to the PNMS through a router. In this case the IP address must be in the same subnet as the router’s serial port.

IP Address Defines the IP address that will be assigned to the PNMS port of the PMC.

RS232C/RS422

Subnet Mask Defines the subnet mask used by the PNMS port of the PMC.

*Option –only available if the PMC used in the Line Concentrator supports LAN connection

Page 45: Net Cfg Tool

ROI-S05945

- 43 -

2.9.10 Setting Properties of MIU (Hop)

This is a type of MIU that is equipped with microwave radio and can be used as CPMC, SCPMC or RPMC. To modify MIU (Hop) properties:

1. Right click on the selected MIU (Hop) to display the context menu. (Or double click on the selected MIU to open the Properties window of the selected MIU.)

2. Click on Properties in the context menu to open the Properties window of the selected MIU (Hop).

3. The Properties window of the MIU contains the parameters shown and defined in Table 2.21.

4. Click on [OK] button after completing the MIU properties setup.

Page 46: Net Cfg Tool

ROI-S05945

- 44 -

Table 2.21 Properties of MIU (Hop)

Parameter Definition Equipment Specifies the type of equipment monitored by the MIU.

They are 2000S or 2300S or 2500S or 2600S or 3000S or 3500S or Other equipment.

Redundancy The redundancy of the selected equipment. (1+0, 1+ 1, or N+1 system.)

Total PMC The total number of PMC’s needed to monitor the selected equipment.

Type When the selected equipment is 2000S or 2500S or 2600S, the termination type is specified in this parameter. The equipment type specified above can either be Repeater or Terminal type.

Repeater Type The repeater type specifies the mode of repeating the signal at the 2600S radio. The 2600S can function as either a “Drop-In’s” or “Through” repeater. This is only available for 2600S radio that has the repeater function enabled. (See also Type.)

Bit Rate ID This parameter specifies the bit rate of the 2500S radio (32MB, 8x2MB or 4x2MB). When Other Equipment is selected the bit rate selection is (34MB, 17MB, or 8MB). This parameter is not available for other equipment types. This data is used for the Block Error Counter (BEC) of the Performance Monitor function.

System

FASYNC Alarm Active Specifies when the FASYNC alarm is active for the selected equipment. (Low Active or High Active) This data is used in UAS measurement of the Performance Monitor.

Name The primary name that will be associated with the target MIU’s symbol in the workspace. This name will be the displayed in the NetCfg Toolj workspace and will NOT be associated to the configuration files. Maximum number of characters possible is 29. To set the NE name for the configuration files, please go to section 2.9.10.1 1) Editing General Parameters of MIU (Hop), Table 2.22) and set the PMC’s individually –if more than one PMC is installed in the target MIU.

Name Position The position where the name of the target MIU will be displayed.

Symbol

Line Direction Defines which side the NMS line will be added to the MIU. MIU PMC Button

[CMPC/SCPCM/RPMC Normal/Additional/etc]

This button contains the NE properties of the MIU. This contains the network, HDLC, port and other parameters connected to the NMS setting of the MIU. It also describes the PMC type (CPMC, SCPMC, or RPMC) and the PMC Usage (Normal, Additional PC, Regular CH, or Protection CH). (See Appendix A: MIU Setting)

Page 47: Net Cfg Tool

ROI-S05945

- 45 -

2.9.10.1 Setting NE Properties of MIU (Hop)

1) Setting/editing the General Parameters of MIU (Hop)

To change the General Configuration Parameters of MIU (Hop):

1. Right click on the selected MIU to display the context menu. (Or double click on the selected MIU to open the Properties window.)

2. Click on Properties in the context menu to open the MIU Properties window.

3. Click on [CPMC (or SCPMC or RPMC) Normal] button in the Properties window.

4. The MIU’s NE Properties window will appear. The default is the General category window, which shows the current configuration. Click on [OK] button to save changes and close the window. [Cancel] button will close the window without saving the changes.

5. In this window, the NE Name, Area Name, Note, Equipment Type, Performance Monitoring, A/D Convert Type and PMC Type can be changed. The definitions of these parameters are listed in Table 2.22.

Page 48: Net Cfg Tool

ROI-S05945

- 46 -

Table 2.22 General Parameters of MIU (Hop)

Parameter Definition NE Name The name that will be assigned to the target NE. This

name will be applied in the configuration files. Maximum number of characters possible is 32.

Area Name The area where the NE is located (optional). Maximum number of characters possible is 32.

Note Additional description of the NE (optional). Maximum number of characters possible is 100.

PMC Usage If the selected MIU contains more than one PMC, the following PMC usage will apply: 1. ) For 1+0/1+1/Line Concentrator/Other Equipment system: a.) 1st PMC is used as Normal. b.) and the other PMC's are used as Additional PMC. 2.) For N+1 system: a) 1st PMC is used as Protection CH. b.) and the other PMC's are used as Regular CH or Additional PMC.

Equipment Type The type of equipment monitored by the target MIU. Performance Monitor Input

The number of MIU channels used for performance monitoring functions. The MIU can accommodate up to 2 CH for performance monitoring purposes.

System

A/D Convert Type

The number of Analog-to-Digital conversions used in the MIU. The MIU is capable of processing a maximum of two (2) A/D conversions.

PMC Type The role of the PMC in the target MIU NE in the HDLC chain.

2) Editing Network Parameters of MIU (Hop)

(Refer to 2.9.6.2 Editing Network Parameters of Pasolink V3, Pasolink V4 and Pasolink-S.)

3) Editing HDLC Parameters of MIU (Hop)

To change the HDLC configuration parameters of MIU (Hop):

1. Right click on the selected MIU to display the context menu. (Or double click on the selected MIU to open the Properties window.)

2. Click on Properties in the context menu to open the MIU Properties window.

3. Click on [CPMC (or SCPMC or RPMC) Normal] button in the Properties window.

4. The MIU’s NE Properties window will appear.

Page 49: Net Cfg Tool

ROI-S05945

- 47 -

5. Select the HDLC category. The HDLC category window contains the parameters concerning the HDLC settings of the target MIU. Note that the HDLC default values are the optimum (recommended) settings. The definition of the HDLC parameters is shown in Table 2.23.

Table 2.23 HDLC Parameters of MIU (Hop)

Parameters Definition Master Timeout

The time in seconds wherein the PMC will assume that it has lost communication link with the master PMC.

Master Interval The time in seconds where in the PMC will check for the polling signal from the master PMC.

HDLC Timer

Slave Timeout The time in seconds wherein the master PMC will assume that the link with its slave PMC is lost.

Auto Role Change

If enabled, the PMC will automatically change its role from slave to master PMC, once it has lost its link with the master PMC in the upper network. It will also automatically change back to slave once the link with the master is restored. This is normally set to "Enable".

Role Change

Role Change Timeout

The elapsed time in seconds that the slave PM card waits for the polling message from the CPMC before it changes itself to assume the role of the CPMC.

HDLC Relay High BER DPU Inhibit

If High BER DPU Inhibit is set to Enable, Hi BER alarm is inhibited. This means that it will not be activated even if the DPU port receives degraded data.

4) Editing Port Parameters of MIU (Hop)

To change the Port configuration parameters of MIU (Hop):

1. Right click on the selected MIU to display the context menu. (Or double click on the selected MIU to open the Properties window.)

2. Click on Properties in the context menu to open the MIU Properties window.

3. Click on [CPMC (or SCPMC or RPMC) Normal] button in the Properties window.

Page 50: Net Cfg Tool

ROI-S05945

- 48 -

4. The MIU’s NE Properties window will appear.

5. Select the Port category. The Port category window contains the parameters defining the port settings of the target MIU. The definition of the Port parameters is shown in Table 2.24.

Table 2.24 Port Parameters of MIU (Hop)

Parameters Definition Action Mode Defines the role of the DPU Port of MIU. Baud Rate Defines the speed of the DPU Port in bits-per-second (bps).

DPU Port

Mode Defines the protocol used in the DPU port. RS-422/RS232 and G.703 can be used in the MIU’s DPU port.

Action Mode Defines the role of the NMS Port of MIU. Baud Rate Defines the speed of the NMS Port in bits-per-second (bps). Mode Auto Assign

If Mode Auto Assign is set to Manual, the mode on the NMS port can be set to RS485_TX or RS485_RX.

Mode Defines the wiring (interface) protocol used Terminal Auto Assign

Automatically allow the NetCfg Toolj to terminate the HDLC connection of the selected NE’s NMS port, if it is the last port in the HDLC line. (Recommended)

NMS Port

Terminate If Terminal Auto Assign is set to Manual, the termination on the NMS port can be set to Enable or Disable. Terminates the RS485 protocol line when enabled

Page 51: Net Cfg Tool

ROI-S05945

- 49 -

5) Editing Other Parameters of MIU (Hop)

To change the Other parameters of MIU (Hop):

1. Right click on the selected MIU to display the context menu. (Or double click on the selected MIU to open the Properties window.)

2. Click on Properties in the context menu to open the MIU Properties window.

3. Click on [CMPC/RPMC Normal] button on the Properties window.

4. The MIU’s NE Properties window will appear.

5. Select the Other category. The Other category window contains the parameters defining the Time and Flash ROM settings of the target MIU. The definition of the other parameters is shown in Table 2.25.

Table 2.25 Other Parameters of MIU (Hop)

Parameter Definition Set Time Auto Set Time If enabled, the PMC automatically sets it time to match

that of the PNMS or the CPMC. Set Time Interval The time interval before the PMC periodically

synchronizes its time to the PNMS or CMPMC. Flash ROM Auto Write Back If enabled, the PMC automatically writes the Log data

and PM data to the Flash ROM. Write Back Interval The time interval before the PMC writes the Log data

and PM data to the Flash ROM.

Page 52: Net Cfg Tool

ROI-S05945

- 50 -

6) Editing PNMS Parameters of MIU (Hop)

To change the PNMS configuration parameters of MIU (Hop):

1. Right click on the selected MIU to display the context menu. (Or double click on the selected MIU to open the Properties window.)

2. Click on Properties in the context menu to open the MIU Properties window.

3. Click on [CPMC (or SCPMC or RPMC) Normal] button on the Properties window.

4. The MIU’s NE Properties window will appear. The default is the General category window, which shows the current configuration.

5. Select the PNMS category. The PNMS category window contains the parameters defining the PNMS connection type, IP address, subnet mask, default gateway and other network parameters of the Line concentrator. As connection LAN or RS232/RS422 is selected, the corresponding parameters in the ensuing box are applied. The definition of the PNMS port parameters is shown in Table 2.26.

Page 53: Net Cfg Tool

ROI-S05945

- 51 -

Table 2.26 PNMS Parameters of MIU (Hop)

Parameter Definition PNMS Connection Defines the type of connection that the PMC in the Line

concentrator has with the PNMS. There are three (3) possible PNMS connections allowed by the PMC namely: RS-232C: PNMS connects to the PMC using RS-232C/19.2kbps Asynchronous interface. RS-422: PNMS connects to the PMC using RS422/19.2kbps/V.11 Asynchronous Interface LAN: PMC connects directly to an Ethernet network using 10BaseT/10Mbps interface.

IP Address Defines the IP address that will be assigned to the LAN-PNMS port of the PMC.

Subnet Mask Defines the subnet mask used by the LAN port of the PMC.

LAN*

Default Gateway

Defines the IP address where of the machine where the traps from the PMC will be forwarded. In cases where the PNMS PC/WS is in the same network (LAN) as the PMC, this will be normally the IP address of the PNMS PC/WS. In case of WAN or networks wherein the PNMS is located in another network, this will be the IP address of the nearest router.

Connection Type

Specifies whether the RS232C/RS422 connection is Direct or through Router. Direct – connection means the PNMS PC connects to the CPMC using its local COM ports. Router – means that the CPMC is connected to the PNMS through a router. In this case the IP address must be in the same subnet as the router’s serial port.

IP Address Defines the IP address that will be assigned to the PNMS port of the PMC.

RS232C/RS422

Subnet Mask Defines the subnet mask used by the PNMS port of the PMC.

*Option –only available if the PMC used in the MIU supports LAN connection.

Page 54: Net Cfg Tool

ROI-S05945

- 52 -

2.9.11 Setting Line Properties

To modify line properties:

1. Right click on the line to display the context menu. (Or double click on the line to open the Line Properties window.)

2. Click on Line Properties in the context menu.

a) For Pasolink Mx/Pasolink+ b) For PasolinkV3/PasolinkV4/Pasolink-S/MIU

c) For PASOLINK NEO

3. The Line Properties window will appear. The Connect Mode(e.g. RS-485 or RS-232C) of any two NEs connected via back-to-back connection can be changed. Connect Port specifies the Pasolink Mx/Pasolink+ port where line (back-to-back) is to be connected – this is only available for Pasolink Mx/Pasolink+ NE’s. Pasolink Mx/Pasolink+ can have back-to-back connections on NE1, NE2 or LAN ports. PASOLINK NEO can have back-to-back connections on EM1(NMS), EM2(NE) or ASYNC ports. Any two NEs connected back-to-back can be assigned a Line Name.

Page 55: Net Cfg Tool

ROI-S05945

- 53 -

4. After user modifies Line Name in the Line Properties window, Line Name will be displayed on the Network window as follows.

Page 56: Net Cfg Tool

ROI-S05945

- 54 -

2.10 Creating Configuration The Create Configuration function allows flexible network configurations. This function can automatically configure PM Cards and PNMS. IP Addresses and PM Type are automatically assigned to the PM Cards in the workspace. (Configuration is carried out, based on the permissible number of NEs per network)

To create configurations:

1. Verify that the workspace is completed and that all the NEs and back-to-back (B-B) lines for this network have been inserted.

2. Click on Tools Create Configuration in the main menu.

3. The create configuration window wizard will be displayed. Click on [Next] button to

continue.

4. Check the “Automatically set PMC type” box if necessary on the ensuing window. By

ticking this box, NetCfg Toolj will automatically set PMC type and allocate NE's according to the maximum number of NE's that can be contained in a sub-network. Click on [Next] button to continue.

Page 57: Net Cfg Tool

ROI-S05945

- 55 -

5. A message box, stating the status of the configuration will appear. If no errors are encountered during the network configuration, this message will just prompt the user that process was “Completed successfully". Click on [Next] button to continue.

6. Click on [Finish] button to complete the procedure. The [Changed NEs List] button provides information of the NE’s that have been modified when the configuration was created. This is a useful feature when modifying an existing network configuration.

Note: Please refer to 2.11 for the explanation of [Changed NE List] button.

7. Slide the pointer over the NE’s displayed in the workspace to verify if all the NE’s have been assigned with appropriate IP address and names.

Page 58: Net Cfg Tool

ROI-S05945

- 56 -

2.11 Changed NE List This function provides a quick view of the NE’s whose parameters have been changed since the last update of the network. It indicates those NE’s whose configuration data needs to be downloaded to PM cards due to the changes. To make sure that the appropriate Changed NE List is displayed, complete the “Export Configuration File to PM Card” procedure for the active workspace and the downloading of configuration files to the PM Cards before extending or altering the network with the “Create Configuration” function.

This window appears at the end of the “Create Configurations” procedure (See 2.9 Creating Configuration) or click on File Changed NEs List in the main menu.

[Close] button can be used to close the window.

[Save] button can be used to save the listing to a csv file.

[Print] button can be used to print the listing via a printer.

Page 59: Net Cfg Tool

ROI-S05945

- 57 -

2.12 Viewing the Subnet Information NetCfg Toolj allows you to view the subnet information of the currently active or selected network. The subnet information contains the Network Address (and subnet mask) and IP addresses of the NE’s in the selected network.

To view the subnet information:

1. Click on Tools Subnet Information in the main menu.

[Close] button can be used to close the window. [Save] button can be used to save the listing in a csv file. [Print] button can be used to print the listing via a printer.

2. The Subnet Information contains the following information about the selected network:

Network Address column: The network address is divided into two parts –this division is represented by a slash (“/”). The IP address to the left of theslash ( /) is the network address of the NE and the one on the right is that of the subnet mask.

Network Element Name: the name which identifies a network element.

IP Address: The IP address assigned to the NE. For SCPMC’s with two IP addresses, this is normally the Primary IP address assigned to the NE.

Page 60: Net Cfg Tool

ROI-S05945

- 58 -

2.13 Exporting Network Configuration Files 2.13.1 Exporting Network Configuration Files for PNMS

This function exports the data file for the PNMS, which allows the network designer to easily modify the network. The NetCfg Toolj creates a network connection file, which can be later copied to the PNMS directory to facilitate the addition of new NE’s in the NMS network.

To export network configuration file for PMNS:

1. Click on File Export File for PNMS on the main menu.

2. Specify the directory or folder where the NetCfg2Pnms.dat file will be saved. Note: you can save the file in another file name just make sure that the file type is NetCfg TooljFiles (*.dat).

3. Click on [Save] button to continue the process.

4. Verify that the file saved in the specified folder.

Page 61: Net Cfg Tool

ROI-S05945

- 59 -

2.13.2 Exporting Network Configuration Files for PM Card

This function allows the user to create PM card configuration files automatically. NetCfg Toolj, creates the configuration for the given network and exports all configuration files (system.cfg and network.cfg) for each of the specified sites PMC's in the workspace.) This ultimately, saves time and minimizes the potential for error in the network design process.

To export network configuration file for PM Card:

1. Click on File Export Configuration Files for PM Card on the main menu.

2. Specify the directory of the folder where the PM Card network configuration file is to be exported. The exported file should be config (*.cfg) format. The file will be stored in /../PM-Card/Network-x folder.

3. Click on [OK] button to continue the process.

Page 62: Net Cfg Tool

ROI-S05945

- 60 -

4. Changed NEs List window will be displayed as shown below.

5. Click on [Close] button to continue the process.

[Save] button can be used to save the listing in a csv file. [Print] button can be used to print the listing via a printer

6. Warning message window will be displayed as shown below.

7. Click on [OK] button to continue the process.

Note: Contents of the Changed NEs List window are purged. Click on [Cancel] button if the contents of the Changed NEs List window are needed. The previous Changed NE List window will return.

8. Verify that the file has been saved in the designated folder.

Page 63: Net Cfg Tool

ROI-S05945

- 61 -

2.14 Saving Current Workspace This function allows the network designer to save the current workspace in an *.nct file format that can be opened using the NetCfg Toolj for future modifications in the network. It is recommended that the user save the existing workspace for an easier addition, and/or modification of the existing NMS network.

To save the current workspace:

1. Click on File Save from the main menu of the main window.

2. Specify the Folder and File Name where the current workspace is to be saved.

3. Click on [Save] button.

4. Verify that the workspace was saved in the selected folder.

Page 64: Net Cfg Tool

ROI-S05945

- 62 -

2.15 Printing Current Network This function allows the network designer to print the designed network. First please define

the area of the network to be printed.

To define the Print Area:

1. Click on File Print Area Setting from the main menu of the main window.

2. The default printing area (extending over the entire window) is outlined by a light-blue dotted line as shown below.

Page 65: Net Cfg Tool

ROI-S05945

- 63 -

3. To define a different printing area (Print Area), depress the left button of the mouse and draw a box around the desired area as shown below.

4. Click on File Print from the main menu of the main window to start printing.

2.16 About Network Configuration Toolj

To verify the version of the NetCfg Toolj being used:

1. Click on Help About NetCfg Toolj from the main menu of the main window.

2. Click on [OK] button to close the About NetCfg Toolj box.

Page 66: Net Cfg Tool

ROI-S05945

- 64 -

3 Multiple CPMC Workspace

In normal operation PNMS can manage more than one CPMC cluster. This section describes the multiple-CPMC configuration procedure for the PNMS.

By default, the NetCfg Toolj opens one workspace during startup. Each workspace represents one network and each network in turn represents one CPMC cluster or group. The default workspace is displayed as Network – 1 in the NetCfg Toolj window.

To add another CPMC cluster or group

1. Click on Network New. This will open a new workspace in the NetCfg Toolj. Note that each of the newly created workspaces has an asterisk (“*”) appended to its network name, for example, Network-1*, Network-2*, etc. the asterisk will disappear once Create Configuration is executed for this network.

2. Add new workspaces as necessary.

Page 67: Net Cfg Tool

ROI-S05945

- 65 -

3. You have to separately configure (Create Configuration) each workspace/network. Select the network that you wish to configure and then click on Tools Create Configuration.

Note: the configuration files cannot be exported until the asterisk (“*”) in the network name for all of the network workspaces disappears. Therefore, “Export” can only be executed after configuring (Create Configuration) each of the network workspaces.

4. The number of workspace depends on the network-sizing rule defined in the PNMS Engineering Manual.

Page 68: Net Cfg Tool

ROI-S05945

- 66 -

Appendix A: MIU Settings

To view the NE Properties for the individual MIU you have to double click on the CPMC folder of the MIU Property Tree. This appendix will explain the naming conventions used in the PMC setting catalogue shown below.

The name of the PMC button is comprised of two distinct parts: (1) PMC type, (2) PMC Usage. The PMC type can either be RPMC, CPMC or SCPMC depending on the role of the PMC in the HLDC polling.

The PMC Usage depends on the order of the PMC in the MIU and the redundancy. The table below illustrates the PMC usage convention used in the MIU.

Total PMC Redundant System PMC Type/PMC Usage RPMC Normal CPMC Normal

1+0/1+1

SCPMC Normal RPMC Protection CH CPMC Protection CH

N+1

SCPMC Protection CH RPMC Normal CPMC Normal

Total PMC = 1 (Line concentrator/other equipment with no redundancy).

Line Concentrator/ Other Equipment

SCPMC Normal 1+0/1+1 RPMC Additional PMC N+1 RPMC Regular CH For N+1 configuration, the default value of the PMC Usage is Regular CH. When adding new PMC’s the user must alter_the PMC usage of the additional PMC’s individually in the MIU properties window. When changing the PMC Usage a warning message will appear. (i.e when adding a new PMC on the existing system the new PMC should be labeled: Additional PMC.)

Total PMC >= 2

Line Concentrator RPMC Additional PMC The additional PMC’s are in a fixed sequence. When deleting a PMC, the NetCfg Toolj will first delete the last PMC to have been added first. This means you cannot add an additional PMC without deleting the PMC’s below it first.

(1) (2)

Page 69: Net Cfg Tool

ROI-S05945

- 67 -

Appendix B: Subnets

Table B1 Available IP Address and Subnet for Managed Network

Subnet Mask Number of available IP address /subnet Range Network Address

255.255.254.0 (Default)

512 (2 class-C subnets) (0~511) xxx.xxx.xxx.0

255.255.255.0 256 (1 class-C subnet) (0~255) xxx.xxx.xxx.0 (0~127) xxx.xxx.xxx.0 255.255.255.128 128 (2 subnets) (128~255) xxx.xxx.xxx.128 (0~63) xxx.xxx.xxx.0 (64~127) xxx.xxx.xxx.64 (128~191) xxx.xxx.xxx.128

255.255.255.192 64 (4 subnets)

(192~255) xxx.xxx.xxx.192 (0~31) xxx.xxx.xxx.0 (32~63) xxx.xxx.xxx.32 (64~95) xxx.xxx.xxx.64 (96~127) xxx.xxx.xxx.96 (128~159) xxx.xxx.xxx.128 (160~191) xxx.xxx.xxx.160 (192~223) xxx.xxx.xxx.192

255.255.255.224 32 (8 subnets)

(224~255) xxx.xxx.xxx.224 (0~15) xxx.xxx.xxx.0 (16~31) xxx.xxx.xxx.16 (32~47) xxx.xxx.xxx.32 (48~63) xxx.xxx.xxx.48 (64~79) xxx.xxx.xxx.64 (80~95) xxx.xxx.xxx.80 (96~111) xxx.xxx.xxx.96 (112~127) xxx.xxx.xxx.112 (128~143) xxx.xxx.xxx.128 (144~159) xxx.xxx.xxx.144 (160~175) xxx.xxx.xxx.160 (176~191) xxx.xxx.xxx.176 (192~207) xxx.xxx.xxx.192 (208~223) xxx.xxx.xxx.208 (224~239) xxx.xxx.xxx.224

255.255.255.240 16 (16 subnets)

(240~255) xxx.xxx.xxx.240 (0~7) xxx.xxx.xxx.0 (8~15) xxx.xxx.xxx.8 (16~23) xxx.xxx.xxx.16 (24~31) xxx.xxx.xxx.24 (32~39) xxx.xxx.xxx.32 (40~47) xxx.xxx.xxx.40 (48~55) xxx.xxx.xxx.48 (56~63) xxx.xxx.xxx.56 (64~71) xxx.xxx.xxx.64 (72~79) xxx.xxx.xxx.72 (80~87) xxx.xxx.xxx.80 (88~95) xxx.xxx.xxx.88

255.255.255.248

8 (32 subnets)

(96~103) xxx.xxx.xxx.96

Page 70: Net Cfg Tool

ROI-S05945

- 68 -

Subnet Mask Number of available IP address /subnet Range Network Address

(104~111) xxx.xxx.xxx.104 (112~119) xxx.xxx.xxx.112 (120~127) xxx.xxx.xxx.120 (128~135) xxx.xxx.xxx.128 (136~143) xxx.xxx.xxx.136 (144~151) xxx.xxx.xxx.144 (152~159) xxx.xxx.xxx.152 (160~167) xxx.xxx.xxx.160 (168~175) xxx.xxx.xxx.168 (176~183) xxx.xxx.xxx.176 (184~191) xxx.xxx.xxx.184 (192~199) xxx.xxx.xxx.192 (200~207) xxx.xxx.xxx.200 (208~215) xxx.xxx.xxx.208 (216~223) xxx.xxx.xxx.216 (224~231) xxx.xxx.xxx.224 (232~239) xxx.xxx.xxx.232 (240~247) xxx.xxx.xxx.240 (248~255) xxx.xxx.xxx.248 (0~3) xxx.xxx.xxx.0 (4~7) xxx.xxx.xxx.4 (8~11) xxx.xxx.xxx.8 (12~15) xxx.xxx.xxx.12 (16~19) xxx.xxx.xxx.16 (20~23) xxx.xxx.xxx.20 (24~27) xxx.xxx.xxx.24 (28~31) xxx.xxx.xxx.28 (32~35) xxx.xxx.xxx.32 (36~39) xxx.xxx.xxx.36 (40~43) xxx.xxx.xxx.40 (44~47) xxx.xxx.xxx.44 (48~51) xxx.xxx.xxx.48 (52~55) xxx.xxx.xxx.60 (56~59) xxx.xxx.xxx.56 (60~63) xxx.xxx.xxx.56 (64~67) xxx.xxx.xxx.64 (68~71) xxx.xxx.xxx.68 (72~75) xxx.xxx.xxx.72 (76~79) xxx.xxx.xxx.76 (80~83) xxx.xxx.xxx.80 (84~87) xxx.xxx.xxx.84 (88~91) xxx.xxx.xxx.88 (92~95) xxx.xxx.xxx.92 (96~99) xxx.xxx.xxx.96 (100~103) xxx.xxx.xxx.100 (104~107) xxx.xxx.xxx.104 (108~111) xxx.xxx.xxx.108 (112~115) xxx.xxx.xxx.112

255.255.255.252

4 (64 subnets)

(116~119) xxx.xxx.xxx.116

Page 71: Net Cfg Tool

ROI-S05945

- 69 -

Subnet Mask Number of available IP address /subnet Range Network Address

(120~123) xxx.xxx.xxx.120 (124~127) xxx.xxx.xxx.124 (128~131) xxx.xxx.xxx.128 (132~135) xxx.xxx.xxx.132 (136~139) xxx.xxx.xxx.136 (140~143) xxx.xxx.xxx.140 (144~147) xxx.xxx.xxx.144 (148~151) xxx.xxx.xxx.148 (152~155) xxx.xxx.xxx.152 (156~159) xxx.xxx.xxx.156 (160~163) xxx.xxx.xxx.160 (164~167) xxx.xxx.xxx.164 (168~171) xxx.xxx.xxx.168 (172~175) xxx.xxx.xxx.172 (176~179) xxx.xxx.xxx.176 (180~183) xxx.xxx.xxx.180 (184~187) xxx.xxx.xxx.184 (188~191) xxx.xxx.xxx.188 (192~195) xxx.xxx.xxx.192 (196~199) xxx.xxx.xxx.196 (200~203) xxx.xxx.xxx.200 (204~207) xxx.xxx.xxx.204 (208~211) xxx.xxx.xxx.208 (212~215) xxx.xxx.xxx.212 (216~219) xxx.xxx.xxx.216 (220~223) xxx.xxx.xxx.220 (224~227) xxx.xxx.xxx.224 (228~231) xxx.xxx.xxx.228 (232~235) xxx.xxx.xxx.232 (236~239) xxx.xxx.xxx.236 (240~243) xxx.xxx.xxx.240 (244~247) xxx.xxx.xxx.244 (248~251) xxx.xxx.xxx.240 (252~255) xxx.xxx.xxx.252

Page 72: Net Cfg Tool

ROI-S05945

- 70 -

Appendix C: Configuration of Dual Master MIU

At MIU (Line Concentrator) two ports, NMS port and DPU port are available. By default NetCfg Toolj assigns NMS port for the line connection, when the Back-to-Back (BB) line is added. Please use the Line Properties dialog box to change the port selection. Note that in the dual master configuration, only 1 port can be assigned to NMS and 1 other port needs to be assigned to DPU. Otherwise, errors may occur when you run Create Configuration.

Configuration of dual master MIU is described (as illustrated in the example):

1. As illustrated in the figure below, place all the NE symbols in the workspace first, connect them with MIU using BB line.

2. As shown in the figure above the

connections from No.002 and No.007 to No.001 are both assigned to NMS port. You need to use the Line Properties dialog box to convert one of the NMS ports into a DPU port as illustrated in the figure below.

3. After the line properties are modified, MIU

(No.001) will be assigned with 1 NMS port and 1 DPU port. Configuring (Create Configuration) will then be possible.

DPU NMS

Page 73: Net Cfg Tool

ROI-S05945

- 71 -

Appendix D: Incorrect Configuration of MIU (Line Concentrator)

Setting up MIU (Line Concentrator) in a Multi-Drop configuration, please use DPU port on the Master side of the Multi-Drop connection. This is due to the MIU hardware limitations.

1. As illustrated in the figure below, since DPU port is assigned on the Master side of the Multi-Drop, this is a correct configuration and configuring (Create Configuration) would be possible.

2. The configuration below is prohibited. Create Configuration will result in error, since MIU (No.007) may not be set to DPU Port on the Slave side of the Multi-Drop connection.

NMS DPU

Multi-Drop Connection

DPU NMS

Page 74: Net Cfg Tool

ROI-S05945

- 72 -

Appendix E: Incorrect Configuration of Pasolink Mx/Pasolink+

The following configuration is not possible in a mixed network of Pasolink Mx/Pasolink+ and PasolinkV3/PasolinkV4/Paso-S/MIU NE’s, when Pasolink Mx/Pasolink+ NE’s are placed close to the PNMS, and are followed by PasolinkV3/PasolinkV4/Paso-S/MIU.

1. Otherwise errors may occur during configuring (Create Configuration) due to the 19.2kbps IC limitation of the Pasolink Mx/Pasolink+. As illustrated in the example below, No.007 (Pasolink+) is connected to No.009 (Pasolink V3). No.009 becomes CPM, and its connection with No.007 (Pasolink+) is assigned to use PPP Protocol (19.2 kbps); however, the Pasolink+, No.005 and No.007 connection uses ASYNC (19.2 kbps). As a result, in the No.007, a 19.2K IC is required to serve two different protocols, which is not possible. Instead, SYNC (64K) IC is used for the connection.

PPP 19.2 kbps

ASYNC 19.2 kbps

Page 75: Net Cfg Tool

ROI-S05945

- 73 -

2. To change the connection of No.005 and No.007 from ASYNC to SYNC, please use the Line Properties dialog box. Please change the port for No.005 from NE2 to NE1.

3. After the line properties are modified, the configuration will be shown as below and configuring (Create Configuration) will then be possible.

PPP 19.2 kbps

SYNC 64 kbps

Page 76: Net Cfg Tool

ROI-S05945

- 74 -

NE2

NMS

<Pattern 2> NE2 <Pattern 1>

NMS

Appendix F: NMS Port Setting of MIU (Line Concentrator / Hop)

If an MIU (Line Concentrator or Hop type) is included in your system configuration, please confirm the following points related to MIU setting.

1. When the MIU (Line Concentrator or Hop type) is connected as a PASOLINK+ or

PASOLINK Mx multi-drop connection, please confirm that the NMS port is set for each MIU, for example, the connection of No.003 and No.004 in Pattern 1 or No.003 and No.005 in Pattern2.

2. Confirm that “Connect Port” of each MIU is set to “NMS” by opening “Line Properties”

between No.003 and No.004 in Pattern 1 or between No.003 and No.005 in Pattern 2.

Page 77: Net Cfg Tool

ROI-S05945

- 75 -

3. In the above example, please confirm that both MIU’s do not have the same “NMS Port” setting, by opening the “Port” category in “NE Properties”. If they are set to the same mode please reset the “NMS Port” mode for the CPM by selecting the “Manual” mode in the “Mode Auto Assign” setting from the “Port” category in “NE Properties”, so that the “NMS Ports” of both MIUs can communicate by connecting them with a straight cable.

Note: When a 2 system (NE) type MIU is used in the above configuration, please be sure that the “Connect Port” setting for both NEs is “NMS” and that the “Mode” setting of one “NMS Port” is “RS485_TX” and the other is “RS485_RX” or vice versa. If the same mode is set to both NMS Ports, the NMS Ports cannot communicate, because the NMS Ports for both NEs are internally connected by straight cable.

Page 78: Net Cfg Tool

ROI-S05945

- 76 -

NMSNMS

NMS NMS

The dotted square in the following figures shows examples of usage for 2 system (NE) type MIU.

NMS

NMS