TECHNICAL REPORT

DET NORSKE VERITAS

NERA SATCOM AS

EMC AND CLIMATIC TEST OF NERA F77 POWER SUPPLY

REPORT NO. 2004-3513 REVISION NO. 02

Page 2: NERA SATCOM AS - Welcome to Polaris Electronics A/S ... · technical report det norske veritas nera satcom as emc and climatic test of nera f77 power supply report no. 2004-3513 revision
Page 3: NERA SATCOM AS - Welcome to Polaris Electronics A/S ... · technical report det norske veritas nera satcom as emc and climatic test of nera f77 power supply report no. 2004-3513 revision

DET NORSKE VERITAS

Report No: 2004-3513, rev. 02

TECHNICAL REPORT

Page i Reference to part of this report which may lead to misinterpretation is not permissible.

aacabk81.doc

Table of Content Page

1 SCOPE OF WORK...................................................................................................... 1

2 TEST LABORATORY................................................................................................ 1

3 TEST PERIOD............................................................................................................. 2

4 ATTENDING REPRESENTATIVES......................................................................... 2

5 EQUIPMENT UNDER TEST ..................................................................................... 2 5.1 Equipment submitted for tests 2 5.2 Test configuration 2 5.3 Modes of operation 3 5.4 Modifications during testing 3

6 EVALUATION OF PERFORMANCE DURING THE TESTS................................. 3 6.1 Function testing and performance monitoring 3 6.2 Criteria of acceptance 4

7 TESTS.......................................................................................................................... 5 7.1 Power supply 5 7.1.1 Extreme power supply 5 7.2 Durability and resistance to environmental conditions 5 7.2.1 Dry heat 5 7.2.2 Damp heat 6 7.2.3 Low temperature 6 7.3 Unwanted electromagnetic emission 7 7.3.1 Conducted emissions 7 7.3.2 Radiated emissions 8 7.4 Immunity to electromagnetic environment 10 7.4.1 Conducted radiofrequency disturbance 10 7.4.2 Radiated disturbance 11 7.4.3 Electrostatic discharge 13

8 SUMMARY OF TEST RESULTS ............................................................................ 13

9 TEST FACILITIES AND INSTRUMENTS ............................................................. 14

Page 4: NERA SATCOM AS - Welcome to Polaris Electronics A/S ... · technical report det norske veritas nera satcom as emc and climatic test of nera f77 power supply report no. 2004-3513 revision

DET NORSKE VERITAS

Report No: 2004-3513, rev. 02

TECHNICAL REPORT

Page 1 Reference to part of this report which may lead to misinterpretation is not permissible.

aacabk81.doc

1 SCOPE OF WORK A new version of the 24 VDC power supply unit (NERA part no. 104259), which is an integrated module in the NERA F77 Main Communications Unit has been EMC and climatic tested in order to verify compliance with requirements stated in the EU Council Directive 89/336/EEC of 3 May 1989 relating to Electromagnetic Compatibility for ship bridge area application. The testing has been carried out according to relevant parts of the following standard:

• IEC 60945 (2002, Fourth edition): Maritime navigation and radio communication equipment and systems - General requirements - Methods of testing and required test results

Based on evaluation carried out by the manufacturer, only properties that are considered to may have been affected by changes of the new power supply version have been tested. For each test, reference is made to the relevant section or paragraph in the standard. Only one specimen of the NERA F77 power supply unit has been tested. The test results thus apply solely for this specimen.

2 TEST LABORATORY The tests were carried out in the Environmental Test Laboratory at Det Norske Veritas, Høvik, Norway. Laboratory accreditation: NORSK AKKREDITERING, No. TEST 034 P6 – Electromagnetic Compatibility P17 – Environmental Testing P20 – Safety Testing According to NS-EN ISO/IEC 17025. Valid through 22.04.2008. Ambient conditions in the laboratory:

Parameter Required (IEC 60068-1) Actual Temperature 15 – 35 °C 21.1 – 23.5 °C Humidity 25 – 75 % RH (30-60 for ESD) 25 – 35 % RH (32 during ESD) Barometric pressure 860 – 1060 mbar 992 – 1023 mbar

For details about the test facilities and instruments used, see Chapter 9.

Page 5: NERA SATCOM AS - Welcome to Polaris Electronics A/S ... · technical report det norske veritas nera satcom as emc and climatic test of nera f77 power supply report no. 2004-3513 revision

DET NORSKE VERITAS

Report No: 2004-3513, rev. 02

TECHNICAL REPORT

Page 2 Reference to part of this report which may lead to misinterpretation is not permissible.

aacabk81.doc

3 TEST PERIOD The tests were carried out during the time period 18-10 to 08-11-2004.

4 ATTENDING REPRESENTATIVES The following client representative was attending the set-up of the system for testing:

• Bjarne Arthurson

5 EQUIPMENT UNDER TEST

5.1 Equipment submitted for tests A test system assembly comprising the NERA F77 power supply (NERA part no. 104259), which is defined as the test specimen was submitted for test. The power supply is an integrated part of the NERA F77 Main Communications Unit. The NERA F77 power supply will from now on be referred to as EUT (Equipment Under Test).

5.2 Test configuration The following Auxiliary equipment (AE) was used in order to operate and function test the system:

• Antenna system, NERA no: 100788 with a dummy load in place of the antenna • Laptop PC, Toshiba Satellite Pro, 440CDT running the “VtLiteMarine” test program • DC power source The following input/output power and signal ports were identified as relevant for EMC testing: All input and output ports of all units that are conducting power or signals were subject to conducted immunity testing.

Page 6: NERA SATCOM AS - Welcome to Polaris Electronics A/S ... · technical report det norske veritas nera satcom as emc and climatic test of nera f77 power supply report no. 2004-3513 revision

DET NORSKE VERITAS

Report No: 2004-3513, rev. 02

TECHNICAL REPORT

Page 3 Reference to part of this report which may lead to misinterpretation is not permissible.

aacabk81.doc

Test set-up:

Test set-up for operation and monitoring of the EUT. Coupling networks and cabling modifications were applied as required to perform the tests according to the relevant standards.

5.3 Modes of operation The testing was carried out with the EUT • powered by 24 VDC from external source • running a test program that was set to operate the system at maximum RF power output level

5.4 Modifications during testing No modifications of the EUT were necessary to pass the tests.

6 EVALUATION OF PERFORMANCE DURING THE TESTS

6.1 Function testing and performance monitoring Correct function was verified during the tests by • observing the antenna visually • monitoring the RF power output as a function of the current drain from the external power

source and by monitoring the presence of the carrier frequency by means of a pick-up loop antenna and a spectrum analyser

• checking the ability to start up at test conditions

Power Supply NERA part no. 104259

24 VDC

Dummy load Spectrum analyser

Loop antenna Antenna system

F77 Main Comm. Unit

Page 7: NERA SATCOM AS - Welcome to Polaris Electronics A/S ... · technical report det norske veritas nera satcom as emc and climatic test of nera f77 power supply report no. 2004-3513 revision

DET NORSKE VERITAS

Report No: 2004-3513, rev. 02

TECHNICAL REPORT

Page 4 Reference to part of this report which may lead to misinterpretation is not permissible.

aacabk81.doc

6.2 Criteria of acceptance In order to pass each test, the EUT shall meet the following criteria:

• Perform in compliance with the test specifications and referenced standards • No unintentionally movement of the antenna shall occur • RF power output and carrier frequency shall remain unaffected by the test conditions • Not show signs of other malfunctions For EMC emission tests, the criteria of acceptance are described in the relevant Chapters. For the EMC immunity tests, the results are evaluated against performance criteria relating to the operating condition and functional specifications of the EUT defined as follows:

Performance Criterion A (For continuous phenomena): The Equipment Under Test shall continue to operate as intended during and after the test. The degradation of performance or loss is allowed as defined in the technical specification published by the manufacturer.

Performance Criterion B (For transient phenomena): The EUT shall continue to operate as intended after the tests. No degradation of performance or loss of function is allowed as defined in the technical specification published by the manufacturer. During the test, degradation or loss of function or performance which is self recoverable is however allowed but no change of actual operating state or stored data is allowed.

Performance Criterion C: Temporary degradation or loss of function or performance is allowed during the test, provided the function is self recoverable, or can be restored at the end of the test by the operation of the controls, as defined in the relevant equipment standard and in the technical specification provided by the manufacturer.

Page 8: NERA SATCOM AS - Welcome to Polaris Electronics A/S ... · technical report det norske veritas nera satcom as emc and climatic test of nera f77 power supply report no. 2004-3513 revision

DET NORSKE VERITAS

Report No: 2004-3513, rev. 02

TECHNICAL REPORT

Page 5 Reference to part of this report which may lead to misinterpretation is not permissible.

aacabk81.doc

7 TESTS

7.1 Power supply 7.1.1 Extreme power supply Test: 7.1 Extreme power supply Referenced standard: IEC 60092-101 The test was carried out at the following environmental test conditions:

Verification of function Environmental condition Normal power supply Extreme power supply

Dry heat Performance test Performance check Damp heat Performance check - Low temperature Performance test Performance check Normal temperature Performance test Performance check Test characteristics:

Power supply Voltage variation Frequency variation 24 VDC nominal +30 % / -10 % NA

Result: The EUT passed the test

7.2 Durability and resistance to environmental conditions 7.2.1 Dry heat Test: 8.2.2, Functional test Referenced standards: IEC 60068-2-2 Test characteristics: Test temperature: +55 °C Duration: 10 – 16 hours The EUT was placed in the chamber in operating mode at normal room temperature and relative humidity. The temperature was then raised to and maintained at test temperature for 16 hours. At the end of the soak period a performance test was carried out at normal power supply condition and a performance check was carried out at extreme power condition. Result: The EUT passed the test

Page 9: NERA SATCOM AS - Welcome to Polaris Electronics A/S ... · technical report det norske veritas nera satcom as emc and climatic test of nera f77 power supply report no. 2004-3513 revision

DET NORSKE VERITAS

Report No: 2004-3513, rev. 02

TECHNICAL REPORT

Page 6 Reference to part of this report which may lead to misinterpretation is not permissible.

aacabk81.doc

7.2.2 Damp heat Test: 8.3.1 Functional test

Referenced standard: IEC 60068-2-30 Test characteristics:

Parameters Severity levels Temperature Room temp. to +40ºC +40 ºC +40 ºC to room temp. Humidity Room cond. to 93 % RH 93 % RH 93 % RH to room cond. Duration 3 ±½ hrs 10 – 16 hrs 1 hour

The EUT was placed in the chamber at normal room temperature and relative humidity. The temperature was then raised to and maintained at test temperature for 16 hours. The EUT was switched on 30 min. after completion of the 16 hour period and kept operating for 2 hours while the temperature and humidity conditions of the chamber was maintained as specified. A performance check was carried out at normal power supply condition during this period. Result: The EUT passed the test

7.2.3 Low temperature Test: 8.4.2.2, Functional test Referenced standard: IEC 60068-2-1 Test: 8.4.2.3, Functional test Referenced standard: IEC 60068-2-1 Test characteristics: Test temperature: -15 °C, ± 3 °C

Duration: 10 – 16 hours The EUT was placed in the chamber at normal room temperature and relative humidity. The temperature was then reduced to and maintained at test temperature for 16 hours. The EUT was switched on 30 min. after completion of the 16 hour period and kept operating for 2 hours while the temperature conditions was maintained as specified. During this period, a performance test was carried out at normal power supply condition and a performance check was carried out at extreme power condition. Result: The EUT passed the test

Page 10: NERA SATCOM AS - Welcome to Polaris Electronics A/S ... · technical report det norske veritas nera satcom as emc and climatic test of nera f77 power supply report no. 2004-3513 revision

DET NORSKE VERITAS

Report No: 2004-3513, rev. 02

TECHNICAL REPORT

Page 7 Reference to part of this report which may lead to misinterpretation is not permissible.

aacabk81.doc

The total uncertainty for this test is as follows: • Uncertainty of the temperature: < ± 1.9 °C The uncertainty is calculated in accordance with NAMAS document NIS 80, and is given as 2 standard deviations.

7.3 Unwanted electromagnetic emission 7.3.1 Conducted emissions Test: 9.2 Referenced standard: CISPR 16-1 (test equipment) Acceptance criteria:

Frequency range Limits, quasi-peak 10 - 150 kHz 96 – 50 dBμV 0.15 – 0.35 MHz 60 dBμV – 50 dBμV 0.35 - 30 MHz 50 dBμV

Conducted emission was measured on the power input lines The conducted emission levels are shown below.

-15

0

20

40

60

80

100

[dBµV]

10k 20k 40k 100k 200k 400k 1M 2M 3M 5M 10M 30M [Hz]

MES 0975 006 CE +Pwr P LIM CE Maritime QP Bridge and deck zone

-15

0

20

40

60

80

100

[dBµV]

10k 20k 40k 100k 200k 400k 1M 2M 3M 5M 10M 30 [Hz]

MES 0975 007 CE -Pwr P LIM CE Maritime QP Bridge and deck zone

+24 VDC power line, peak detection -24 VDC power line, peak detection

Page 11: NERA SATCOM AS - Welcome to Polaris Electronics A/S ... · technical report det norske veritas nera satcom as emc and climatic test of nera f77 power supply report no. 2004-3513 revision

DET NORSKE VERITAS

Report No: 2004-3513, rev. 02

TECHNICAL REPORT

Page 8 Reference to part of this report which may lead to misinterpretation is not permissible.

aacabk81.doc

Result: The EUT passed the test

The total uncertainty for this test is as follows: • Uncertainty in measured values : ±2.3 dB The uncertainty is calculated in accordance with NAMAS document NIS 81, and is given as 2 standard deviations.

7.3.2 Radiated emissions Test: 9.3 Referenced standard: CISPR 16-1 (test site and equipment) Acceptance criteria:

Frequency range Limits, quasi-peak at 3 m 150 kHz – 300 kHz 80 – 52 dBμV/m 300 kHz – 30 MHz 52 – 34 dBμV/m 30 – 156 MHz 54 dBμV/m 156 –165 MHz 24 dBμV/m 165 – 2000 MHz 54 dBμV/m

In order to detect the highest emission levels, the tests were carried out with the EUT in varying azimuth orientations relative to the antenna and with antenna elevation adjusted between 1 and 4 m (fixed position and height 1.5 m below 30 MHz). The position of cables was varied to find the condition for maximum emission.

Page 12: NERA SATCOM AS - Welcome to Polaris Electronics A/S ... · technical report det norske veritas nera satcom as emc and climatic test of nera f77 power supply report no. 2004-3513 revision

DET NORSKE VERITAS

Report No: 2004-3513, rev. 02

TECHNICAL REPORT

Page 9 Reference to part of this report which may lead to misinterpretation is not permissible.

aacabk81.doc

EUT during radiated emission test

The measurements were performed at various azimuth orientations with the antenna 1.5 m above the ground plane. Distance to the antenna was 3 m. The quasipeak measurements were carried out for frequencies where the quasipeak limits were exceeded in max-peak detection measurement.

20

30

40

50

60

70

80

Level [dBµV/m]

150k 300k 500k 1M 2M 3M 4M 5M 7M 10M 30MFrequency [Hz]

MES 0975 014-017 LIM RE Maritime QP

23.9

26.0

28.0

30.0

32.0

34.0

36.0

38.0

40.0

41.2

Level [dBµV/m]

7.07M 10M 12M 14M 16M 19.2MFrequency [Hz]

MES 0975 018 000 L1.5 Q MES 0975 019 000 L1.5 Q LIM RE Maritime QP

Maximum radiated emission 150 kHz - 30 MHz, max-peak detection

Maximum radiated emission, quasi-peak detection

Page 13: NERA SATCOM AS - Welcome to Polaris Electronics A/S ... · technical report det norske veritas nera satcom as emc and climatic test of nera f77 power supply report no. 2004-3513 revision

DET NORSKE VERITAS

Report No: 2004-3513, rev. 02

TECHNICAL REPORT

Page 10 Reference to part of this report which may lead to misinterpretation is not permissible.

aacabk81.doc

Result: The EUT passed the test The total uncertainty for this test is as follows: • Uncertainty in measured values (30-600MHz, vertical polarization): ±5.5 dB • Uncertainty in measured values (30-200MHz, horizontal polarization): ±3.5 dB The uncertainty is calculated in accordance with NAMAS document NIS 81 and given as 2 standard deviations. Reference: DNV Test laboratory, Procedure for Equipment and Services, No 16.3.6, date 01.07.31

7.4 Immunity to electromagnetic environment

7.4.1 Conducted radiofrequency disturbance Test: 10.3 Acceptance criterion: A Referenced standard: IEC 61000-4-6 The following ports were tested: 24 VDC power input (decoupling via RF output port) RF output port (decoupling via DC power input port) Test characteristics:

Parameters Severity levels Frequency 0.15 – 80 MHz 2 – 3 – 4 – 6.2 – 8.2 – 12.6 –

16.5 – 18.8 – 22 and 25 MHz. Amplitude 3 Vrms 10 Vrms Modulation 80% AM, 0.4 kHz Sweep rate ≤1.5x10-3 dec./s No. of sweeps 1

Page 14: NERA SATCOM AS - Welcome to Polaris Electronics A/S ... · technical report det norske veritas nera satcom as emc and climatic test of nera f77 power supply report no. 2004-3513 revision

DET NORSKE VERITAS

Report No: 2004-3513, rev. 02

TECHNICAL REPORT

Page 11 Reference to part of this report which may lead to misinterpretation is not permissible.

aacabk81.doc

Set-up for conducted RF immunity testing on power port Result: The EUT passed the test The total uncertainty for this test is as follows: • Uncertainty in applied voltage: ±2.55 dB The uncertainty is calculated in accordance with NAMAS document NIS 81, and is given as 2 standard deviations.

7.4.2 Radiated disturbance Test: 10.4

Referenced standard: IEC 61000-4-3 Acceptance criterion: A Test characteristics:

Parameters Severity levels Frequency 80 – 1000 MHz 1 – 2 GHz Sweep rate 1.5x10-3 decade/s 0.5x10-3 decade/s Field strength 10 V/m Modulation 80% AM, 0.4 kHz Number of sweeps 1

Page 15: NERA SATCOM AS - Welcome to Polaris Electronics A/S ... · technical report det norske veritas nera satcom as emc and climatic test of nera f77 power supply report no. 2004-3513 revision

DET NORSKE VERITAS

Report No: 2004-3513, rev. 02

TECHNICAL REPORT

Page 12 Reference to part of this report which may lead to misinterpretation is not permissible.

aacabk81.doc

The distance between the antenna and the calibrated field area was 3 m EUT during radiated electromagnetic field immunity testing:

EUT set-up for radiated disturbance testing Result: The EUT passed the test The total uncertainty for this test is as follows: • Uncertainty in applied field strength (1m antenna distance): -2.2/+2.9 dB • Uncertainty in applied field strength (3m antenna distance): -2.0/+2.7 dB The uncertainty is calculated in accordance with NAMAS document NIS 81, and is given as 2 standard deviations.

Page 16: NERA SATCOM AS - Welcome to Polaris Electronics A/S ... · technical report det norske veritas nera satcom as emc and climatic test of nera f77 power supply report no. 2004-3513 revision

DET NORSKE VERITAS

Report No: 2004-3513, rev. 02

TECHNICAL REPORT

Page 13 Reference to part of this report which may lead to misinterpretation is not permissible.

aacabk81.doc

7.4.3 Electrostatic discharge Test: 10.9 Referenced standard: IEC 61000-4-2 Acceptance criterion: B Test characteristics:

Parameters Severity levels Amplitude Contact:

Air: ±6 kV ±8 kV

Number of discharges 10 per point/polarity Repetition rate 1 per s

Accessible conducting parts of the EUT were subject to contact discharge, while insulated accessible surfaces were subject to air discharge. Additionally, the EUT was exposed to the impact of contact discharge against a vertical coupling plane positioned 10 cm from the EUT. Contact discharge points: • 5 selected points on the power supply enclosure front and top Air discharge points: • No accessible surface of the EUT was insulated and relevant for contact discharge testing Result: The EUT passed the test

The total uncertainty for this test is as follows: • Uncertainty in risetime (10%/90%) in first peak of the discharge pulse: < ± 17% • Uncertainty in first peak value of the discharge pulse: < ± 8% • Uncertainty in the discharge pulse value at 30ns: < ± 30% • Uncertainty in the discharge pulse value at 60ns: < ± 30% The uncertainty is calculated in accordance with NAMAS document NIS 81, and is given as 2 standard deviations.

8 SUMMARY OF TEST RESULTS The EUT passed all the tests.

Page 17: NERA SATCOM AS - Welcome to Polaris Electronics A/S ... · technical report det norske veritas nera satcom as emc and climatic test of nera f77 power supply report no. 2004-3513 revision

DET NORSKE VERITAS

Report No: 2004-3513, rev. 02

TECHNICAL REPORT

Page 14 Reference to part of this report which may lead to misinterpretation is not permissible.

aacabk81.doc

9 TEST FACILITIES AND INSTRUMENTS

Instrument Description Make Model Serial number Power Amplifier Amplifier Research 100A250 20028 Signal Generator Rohde & Schwarz SML03 /B3 101019 Power Amplifier Amplifier Research 200W1000M7 12949 Power Amplifier Milmega AS0825-65 1006210 Log-periodic antenna Amplifier Research AT1080 17257 Horn Antenna Eaton 91888-2 537 Dual Directional Coupler Amplifier Research DC6280M1 14768 Field Monitor Amplifier Research FM2000 12784 Field Strength Probe Amplifier Research FP2080 20237 Bi-log Antenna Schaffner CBL6143 5092 Coaxial Attenuator 6dB Huber+Suhner 6806.17.A Batch 6692B SW for radiated immunity testing Rohde & Schwarz EMC32 NA SW for conducted RF susceptibilty Rohde & Schwarz EMC32 NA Turntable H. Deisel DS 420 - Controller H. Deisel HD 100 100/371 Bj:95 Antenna Mast H. Deisel MA 240 240/354 Bj:95 Electrostatic Discharge Generator EM Test DITO 1003-24 Coupling/Decoupling Network Lüthi CDN801- M2/M3 9450196 50-150 Ohm adaptor Lüthi CR100A 1 Coupling/Decoupling Network Lüthi CDN801-S8 9450209 Decoupling clamp Fischer Custom

Communications, Inc. FCC-2031-DCN 113

Artificial Mains Network EMCO 3825/2 1656 SW for emission testing Rohde & Schwarz ES-K1 1026.6790.02 EMI Test Receiver Rohde & Schwarz ESIB26 1088.7490 Signal Generator Rohde & Schwarz SML03 /B3 101475 Semi-anechoic Chamber Siemens Matsushita

Components NA NA

Climatic Chamber (2) Heraeus Vötsch VSKZ 04/90/S 44055 SW for Climatic Chamber Vötsch SIMPATI V 2.02

- o0o -