diagnostic ultrasound systemProduct Data No. MPDUS0017EA

V1.0

oUtliNENemioTM MX (SSA-590A) is a compact full-digital color diagnostic ultrasound system. This next-generation system has achieved high image quality and high sensitivity using advanced technologies. Superiorimagingperformance Nemio MX includes THI (Tissue Harmonic Imaging) in the standard configuration and generates high-quality B-mode images. Advanced DYNAMIC FLOWTM, which produces high-resolution blood flow images and is a feature of topof-the-line systems, and ApliPureTM, which is compounding technology for high contrast resolution, are supported. Thus, Nemio MX provides high-end imaging performance. Sophisticatedergonomics A 15-inch LCD monitor whose brightness has been adjusted appropriately for the display of ultrasound images is used in Nemio MX. The displayed images are easy-toview and their excellent visibility is relatively insensitive to the brightness of the room. A flexible multijoint arm supports the LCD monitor, allowing appropriate positioning for operations in the standing or sitting posture to be achieved easily. A lightweight body has been achieved through the use of the LCD monitor, making it much easier to move the system around in the hospital. Functions can be assigned freely to buttons on the operating panel to suit individual preferences. Also, operation protocols can be registered in advance, allowing examinations to be performed smoothly with simple operations (Sonoset). In addition, the B-mode image quality can be adjusted appropriately with a single operation using the IP dial or QuickScan. Efficientdatamanagement A large-capacity HDD is provided in the standard configuration, facilitating efficient management of acquired images. Filed images can be output via the USB port or stored on CD/DVD. DICOM is supported by the optional Advanced Data Management board. In addition, Stress Echo and the reporting function can be installed as options.

SyStEM MAtrix for SSA-590Ano. 1 Main unit unit model name SSA-590A remarks Including color Doppler, DVD drive, THI, PW, Sector, 15-inch LCD monitor, QuickScan, Sonoset PSP for 2D/CDI, QSP for CDI Enables CWD capabilities. Pencil transducer connector is included. Reference signal display unit + ECG cable PCG sensor Adds a 3rd transducer port. Foot SW + connector kit for Main unit. Data Management unit with filing, DICOM storage, and report functions Add QSP/PSP, 3rd transducer port, CW, Reference signal unit, Dynamic Flow and Directional Color Angio. ECG, CWD (without pencil transducer support). For digital printers Enables OB 4D scan using PVM-375MV. UIDM-590A, UIPS-590A, and UIQS-590A are required. For mounting a color printer or DVD recorder (with cables) For mounting a color printer and a DVD recorder (with cables) Enables directional display in Color Angio mode (Directional Color Angio). Enables trapezoid scan function. Enables High PRF PW Doppler.

2 B-PSP & CDI-PSP/QSP kit UIQS-590A 3 CW kit 4 Reference signal kit 5 6 7 8 9 Transducer selector M-TEE hanger kit Footswitch kit Gel warmer Data Management unit UICW-590A UJUR-590A UJUR-592A UIPS-590A UAEH-590A UZFS-590A UZGW-590A UIDM-590A UIUG-590A UICV-590A UZCA-590A UIMV-590A UZRI-590A UZRI-591A USDA-590A USTS-590A USHP-590A USTD-590A USHI-590A USTI-590A USAC-590A USDF-590A UDDS-590A UDSE-590A UDPA-590A

10 Premium kit 11 CV kit 12 Cable for printer 13 Mecha 4D kit Mounting kit for peripheral unit (for a single unit) Mounting kit for peripheral 15 unit (for 2 units) 16 DCA kit 17 Trapezoid scan kit 18 HPRF kit 19 TDI kit 20 CHI/FEI kit 14 21 TIC kit 22 ACM kit 23 Dynamic Flow kit 24 DICOM system kit 25 Stress Echo kit 26 Panoramic View kit

Enables Time-Intensity Curve generation. USHI-590A is required. Automated Cardiac Flow Measurement

2

MPDUS0017EA

trANSDUcEr oPtioNSmodel name PSM-20CT PSM-50AT PSM-70AT PSM-30BT PSM-37CT PEF-510MA PEF-704LA PVM-375AT PVM-672AT PVM-662AT PVM-651VT PVM-740RT PVM-787LA PVM-620ST PVF-620ST PVM-381AT PVF-381MT PVF-738H PVF-738F PVF-745V PVL-715RT PLM-503AT PLM-703AT PLM-805AT PLM-1202S PLM-1204AT PLF-308P PVM-375MV PC-19M PC-50V*1: *2: *3 *4

scan type Sector 90 Sector 90 Sector 90 Sector 90 Sector 90 Sector 90 Linear 34 mm Convex 70 Convex 62 Convex 62 Convex 143 Convex 144 Convex 85 Convex 144 Convex 144 Convex 75 Convex 75 Convex 32 Convex 32 Convex 38 Linear 53 mm Convex R53 143 Linear 32 mm Linear 32 mm Linear 56 mm Linear 25 mm Linear 32 mm Linear 85 mm Convex Pencil Pencil

Freq. (mHz) 2.0 5.0 7.0 3.0 3.75 5.0 7.0 3.75 6.0 6.0 6.0 7.0 7.0 6.0 6.0 3.75 3.75 7.0 7.0 7.0 7.0 7.0 5.0 7.5 8.0 12.0 12.0 3.75 3.75 1.9 5.0 3.0 6.0 10.0 3.7 5.0 6.0 10.0 6.0 8.0 8.0 7.5 10.0 10.0 7.5 7.5 6.0 6.0 10.0 10.0 10.0 12.0 10.0 8.5 11.0 12.0 14.0 14.0 5.0 6.0

multi-freq. (mHz) B-mode tHi 2.5 4.5 7.5 3.0 4.2 5.0 7.5 4.2 7.0 7.0 6.0 7.5 7.5 6.0 6.0 3.7 3.7 7.5 7.5 7.5 9.0 7.5 7.2 9.0 9.0 12.0 12.0 4.0 4.2 2.0 3.7 5.0 2.0 3.2 3.7 5.0 3.0 5.7 5.7 5.0 5.0 5.0 4.0 4.0 3.0 3.0 5.0 5.0 5.0 6.0 5.0 6.0 6.0 6.0 8.0 8.0 3.0 3.0 3.8 6.0 4.0 4.8 6.0 5.0 8.0 10.0 4.8 4.8 9.0 11.0 12.0 5.0 3.6 5.6 3.6 4.6 5.6 4.6 6.5 8.0 4.6 4.6 7.0 9.0 10.0 4.6

application Transcranial Doppler (Pediatric) Heart Pediatric heart Adult heart Abdominal Multiplane TEE Laparoscopic Abdomen Neonatal head Neonatal head Endovaginal Endorectal Laparoscopic Endocavitary Endocavitary Adult heart, abdomen Adult heart, abdomen Intraoperative Abdominal, small parts Intraoperative Endorectal (Biplane) Vascular Carotid Small parts Small parts Intraoperative Small parts Abdominal biopsy OB fetus Heart Doppler Peripheral Vascular*1 *1 *1

remarks

*4

*4 *1

*1

*4

*4

*2 *3 *3

UIQS-590A is required for THI. UIDM-590A, UIPS-590A, UIMV-590A, and UIQS-590A are required. Only for 3rd port. Premium kit and CV kit (UICV-590A) or UICW-590A is required. These transducers are no longer available for purchase. The transducers at the customer sites can still be used.

3

block chArt SyStEMSNemio MX Main unit SSA-590A B-PSP & CDI-PSP/QSP kit UIQS-590A CW kit UICW-590A Trapezoid scan kit USTS-590A Reference signal kit UJUR-590A Reference signal kit UJUR-592A Transducer selector UIPS-590A M-TEE hanger kit UAEH-590A Footswitch kit UZFS-590A Gel warmer UZGW-590A Data Management unit UIDM-590A DICOM system kit UDDS-590A Stress Echo kit UDSE-590A Panoramic View kit UDPA-590A Mecha 4D kit UIMV-590A* 4D transducer PVM-375MV

A

DCA kit USDA-590A HPRF kit USHP-590A TDI kit USTD-590A ACM kit USAC-590A CHI/FEI kit USHI-590A TIC kit USTI-590A Dynamic Flow kit USDF-590A Mounting kit for peripheral unit (for a single unit) UZRI-590A Mounting kit for peripheral unit (for 2 units) UZRI-591A

A

* UIQS-590A and UIPS-590A are required.

4

MPDUS0017EA

SPEcificAtioNSSystemTransducer: Focusing: M-serieswithEchoBooster (Chip-in-the-Tip) AutofocusingwithDigital Continuous Beam Former of ROI-tracing type Available

Imageprocessing:

Dynamic range: Edge enhancement: Automatic gain control: Postprocessing: Temporal smoothing: Spatial smoothing: Contrast enhancement: Framerate: CompoundingScan (ApliPure): AutoSTC/GAIN adjustment (QuickScan):

5IPtypesareavailable. The following parameters can be controlled. 30 to 100 dB (can be set independently for 2D and M) OFF, 1, 2, 3 4 types 2D, 8 types OFF, 1 to 5 4 types OFF, ON (can be set independently for 2D and THI) Max.391frames/s Available with all convex and linear transducers

ProtocolRegistration (SonoSet):

2D-andM-modesScanningmethods:

Electronicconvexscan Electronic linear scan Electronic sector scan Electronic trapezoid scan** Available with PLM-703AT, PLM-805AT, PLM-1204AT, PLM-503AT, PLM-1202S, PLF-308P, PEF-704LA, PVL-715RT

Scanwidth:

WIDE(100%)/WIDE-MIDDLE (80%)/MEDIUM(70%)/ NARROW(50%)/FREE(Min. 20) 2 to 24 cm, 1-cm steps L, H 10 Max. 5 (including THI) Single 1, 2, 4, 8 s/screen Moving bar 8 steps max. Continuous 62 to 100 dB for B-mode 52 to 110 dB for M-mode 8-step sliding VRs. Corresponds to the viewing depth

Available

2D Depth: Line density: Independent steering angle: Multiple frequencies: M-mode Channel: Sweep speed: Display method: Focusing Transmission: Reception: Gainadjustment Palm controller: STC (DGC):

4D(UIDM-590A,UIPS-590A,UIMV-590A, UIQS-590A,andPVT-375MVarerequired)Acquisitionmodes: Displaymodes:

3Ddisplaymodes: Reviewmodes:

Measurements: Imagestorage: Controlmethod:

4DLive,SingleSweep Singledisplayofa2Dimage, Single diplay of a 4D image, Single display of a planar image of a 4D image, Dual display of a 4D image and a planar image, 4-frame display of a 4D image and three planar images, Multiframe display of planar images of a 4D image Real-time,Freeze 4Dvolumecineplayback,movie play back, frame-by-frame playback Distance,angle,area 4Dvolume,movie(dynamic image), still image Operationfromthemainpanel (switches, paddle switches, rotary encoders)

5

SpectrumDoppler(SD)Mode:

Pulsed-WaveDoppler(PWD), Continuous-Wave Doppler with Pencil Transducer, Full Steerable Continuous-Wave Doppler (SCWD) 1.3 to 15.2 kHz, PWD 5.8 to 15.2 kHz, HPRF (USHP-580A is required) 4.0 to 47.6 kHz, CWD 31dB(1-dBsteps) PWD,7steps CWD, 7 steps 13steps(1to15mm) Reverse(toward/awayflow) display, Base shift, B-refresh (Manual, Time, ECG-Sync), D-expand, 2D/D-expand, Angle mark 20 max. (2 steps) 2D+SD(verticallayout,horizontal layout) SD Baseshift,VelocityRange Available

Pulserepetition frequency (PRF):

Gain: Dopplerfilter: Samplingwidth: Displaycontrol:

Independentsteering angle: Audiostereooutput Displayformat:

Velocityrange(scale) The following parameters can be changed with one dial. Alternative step: 16