    Multi Hazard Building Design

    Earthquake Loads

    Consulting Engineers Partnership Ltd

    Grenville W Phillips IIBSc, BEng, MASc, MURP, CEng, MIStructE, MIHT, MAPM, MCSCE, MBAPE

  • 8/10/2019 NEHRP Revised

    2/26

    Design Spectral Response

    Acceleration SDS = 5% damped design spectral

    response acceleration at short periods =2/3 SMS

    SMS = Maximum considered earthquake

    spectral response accelerations for shortperiods = Fa.Ss

    Fa = Site Coefficient Ss = Mapped spectral accelerations for

    short periods.

  • 8/10/2019 NEHRP Revised

    3/26

    Site Classification

    Note: Top soil layer to be continuous 30 m (100 ft)

  • 8/10/2019 NEHRP Revised

    4/26

  • 8/10/2019 NEHRP Revised

    5/26

  • 8/10/2019 NEHRP Revised

    6/26

    Site Coefficient

  • 8/10/2019 NEHRP Revised

    7/26

  • 8/10/2019 NEHRP Revised

    8/26

    Seismic Use Group II

    Those that have a substantial public hazard due to occupancy or use including:

    1. Covered structures whose primary occupancy is public assembly with acapacity greater than 300 persons

    2. Educational structures through the 12th grade with a capacity greater than250 persons

    3. Day care centers with a capacity greater than 150 persons

    4. Medical facilities with greater than 50 resident incapacitated patients nototherwise designated a Seismic Use Group III structure

    5. Jails and detention facilities

    6. All structures with a capacity greater than 5,000 persons

    7. Power generating stations and other public utility facilities not included inSeismic Use Group III and required for continued operation

    8. Water treatment facilities required for primary treatment and disinfection forpotable water

    9. Waste water treatment facilities required for primary treatment.

  • 8/10/2019 NEHRP Revised

    9/26

    Seismic Use Group III

    Essential facilities required for post-earthquake recovery and those

    containing substantial quantities of hazardous substances including:1. Fire, rescue, and police stations

    2. Hospitals

    3. Designated medical facilities having emergency treatment facilities

    4. Designated emergency preparedness centers

    5. Designated emergency operation centers

    6. Designated emergency shelters

    7. Power generating stations or other utilities required as emergency back-up facilities for Seismic Use Group III facilities

    8. Emergency vehicle garages and emergency aircraft hangars9. Designated communication centers

    10. Aviation control towers and air traffic control centers

    11. Structures containing sufficient quantities of toxic or explosivesubstances deemed to be hazardous to the public

    12. Water treatment facilities required to maintain water pressure for firesuppression.

  • 8/10/2019 NEHRP Revised

    10/26

    1. Seismic Design Category A

    Minimum Lateral Force at level x (Fx)

    Fx = 1%.wx ; w = effective seismic weight

    Connections between separation joints Fp = 5%.weight of smaller portion

  • 8/10/2019 NEHRP Revised

    11/26

    2.2 Seismic Use Group I

    V = Seismic base shear

    W = effective seismic weight

    R = Response modification factor

    SDS = Design elastic response acceleration at short periods.

  • 8/10/2019 NEHRP Revised

    12/26

    2.3 Seismic Use Group I

    Minimum Lateral Force at level x (Fx)

    Design Storey Drift = 1% Storey Height

  • 8/10/2019 NEHRP Revised

    13/26

    VERTICAL FORCE

    DISTRIBUTION

  • 8/10/2019 NEHRP Revised

    14/26

    3.1 Equivalent Lateral Force

    Procedure

    V = seismic base shear

    Cs = seismic response coefficient

    R = Response modification factor

    SDS = Design elastic response acceleration at short periods.

    I = Occupancy Importance Factor

  • 8/10/2019 NEHRP Revised

    15/26

    Seismic Use Group I

    Occupancy Importance FactorsThose not assigned to Seismic Use Groups

    III or II

  • 8/10/2019 NEHRP Revised

    16/26

    The Four Main Types

    Bearing Walls?

    Shear Walls?

    Braced Frame?

    Moment Frame?

    25% Moment frame

    + shear walls or

    braced frame?

    Bearing wall system

    Building frame system

    Moment resisting

    frame system

    Dual system

    Yes

    Yes

    YesNo

    No

    No

    No

    Yes

    Yes

  • 8/10/2019 NEHRP Revised

    17/26

  • 8/10/2019 NEHRP Revised

    18/26

  • 8/10/2019 NEHRP Revised

    19/26

    3.2 Equivalent Lateral Force

    Procedure

    T = the fundamental period of the structure (in seconds) = 0.1N

    TL = Long-period transition period (in seconds)

    N = Number of storeys above ground level.

    Cs shall not be taken less than 0.01.

    For regular structures 5 stories or less

    with max period, T, of 0.5 sec, Cs, can becalculated using values of 1.5 and 0.6,

    respectively, for the mapped maximum

    considered earthquake spectral response

    acceleration parametersSS

    and S1.

  • 8/10/2019 NEHRP Revised

    20/26

    3.3 Equivalent Lateral Force

    Procedure

    Cvx = vertical distribution factor,

    V = total design lateral force or shear at the base of the structure,

    wi and wx = the portion of the total gravity load of the structure,W, located or assigned to Level i orx,

    hi and hx = the height from the base to Level i orx, and

    k= an exponent related to the effective fundamental period ofthe structure as follows: T =2.5, k = 2

  • 8/10/2019 NEHRP Revised

    21/26

    3.4 Equivalent Lateral Force

    Procedure

    Mx= Overturning moments at Level

    x,Fi = the portion of the seismic base shear, V, induced at

    Level i, and

    hi and hx = the height from the base to Level i orx.

  • 8/10/2019 NEHRP Revised

    22/26

    3.5 Equivalent Lateral Force

    Procedure

    x= deflections of Level

    x,Cd= the deflection amplification factor,

    xe = the deflections determined by an elastic analysis, and

    I = the occupancy importance factor

  • 8/10/2019 NEHRP Revised

    23/26

    3.6 Equivalent Lateral Force

    Procedure Allowable Storey Drift (inches)

    Seismic Use Group

    Building I II III

    Buildings other than masonry shear

    wall, 4 storeys or less

    0.025 hx 0.02 hx 0.015 hx

    Masonry cantilever shear wallbuildings

    0.01 hx 0.010 hx 0.010 hx

    Other masonry shear wall buildings 0.007 hx 0.007 hx 0.007 hx

    Masonry wall frame 0.013 hx 0.013 hx 0.010 hx

    All other buildings 0.020 hx 0.015 hx 0.010 hx

    hx = storey height below level x

    DISCONTINUOUS SOIL LAYER

  • 8/10/2019 NEHRP Revised

    24/26

    DISCONTINUOUS SOIL LAYER

    Shear Wave Velocity

    DISCONTINUOUS SOIL LAYER

  • 8/10/2019 NEHRP Revised

    25/26

    DISCONTINUOUS SOIL LAYER

    Standard Penetration ResistanceNi = the Standard Penetration Resistance determined in

    accordance with ASTM D 1586, as directly measured in thefield without corrections, and shall not be taken greater than

    100 blows/ft. Where refusal is met for a rock layer,Ni shall be

    taken as 100 blows/ft.

    DISCONTINUOUS SOIL LAYER

  • 8/10/2019 NEHRP Revised

    26/26

    DISCONTINUOUS SOIL LAYER

    Undrained Shear Strength sui = the undrained shear strength in psf

    (kPa), determined in accordance withASTM D 2166 or D 2850, and shall not be

    taken greater than 5,000 psf (250 kPa)