R Project Description The project includes: The existing 44 kV transmission line would remain in place and operational until the new Eaton-area substation to Cloverly Substation segment is constructed and energized; at which time the 44 kV line would be removed. Station 3 : Project Description • Board 9 A 230 kilovolt (kV) double-circuit transmission line from the Western Area Power Administration (WAPA) Ault Substation to the new Xcel Energy Husky Substation. One circuit would be installed initially and operated at 230 kV. The new Husky Substation would replace the Xcel Energy Ault 44 kV Substation, which would be decommissioned. (In November 2018, a site plan for the new Husky Substation in the Town of Ault was submitted and was approved in February 2019.) A 230 kV transmission line would be constructed to support two circuits (double-circuit) from the new Husky Substation to a new Eaton-area substation. A 115 kV circuit would be installed initially and a 230 kV circuit would be installed in the future when additional electric service is needed. The new Eaton-area substation would replace the existing Xcel Energy Eaton 44 kV Substation, which would be decommissioned. The new Eaton-area substation would accommodate upgrades to the local electrical distribution system. A transmission line would be constructed to support two circuits (double circuit) from the new Eaton-area substation to Xcel’s existing Cloverly Substation. A 115 kV circuit would be installed initially and a 230 kV circuit would be installed in the future when additional electric service is needed.

NCAP OH3Boards Station3

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: NCAP OH3Boards Station3

R

Project Description

The project includes:

The existing 44 kV transmission line would remain in place and operational until

the new Eaton-area substation to Cloverly Substation segment is constructed and

energized; at which time the 44 kV line would be removed.

Station 3 : Project Description • Board 9

• A 230 kilovolt (kV) double-circuit transmission line from the Western Area Power Administration (WAPA) Ault Substation to the new Xcel Energy Husky Substation. One circuit would be installed initially and operated at 230 kV.

• The new Husky Substation would replace the Xcel Energy Ault 44 kV Substation, which would be decommissioned. (In November 2018, a site plan for the new Husky Substation in the Town of Ault was submitted and was approved in February 2019.)

• A 230 kV transmission line would be constructed to support two circuits (double-circuit) from the new Husky Substation to a new Eaton-area substation. A 115 kV circuit would be installed initially and a 230 kV circuit would be installed in the future when additional electric service is needed.

• The new Eaton-area substation would replace the existing Xcel Energy Eaton 44 kV Substation, which would be decommissioned. The new Eaton-area substation would accommodate upgrades to the local electrical distribution system.

• A transmission line would be constructed to support two circuits (double circuit) from the new Eaton-area substation to Xcel’s existing Cloverly Substation. A 115 kV circuit would be installed initially and a 230 kV circuit would be installed in the future when additional electric service is needed.

Page 2: NCAP OH3Boards Station3

Station 3 : Project Description • Board 10

N

Project Study Area

The information contained herein is demonstrative only, believed to be accurate and suitable for limited, internal Xcel Energy use only. Maps are not to scale. All matters depicted including but not limited to utility facilities, locations, and materials are preliminary only and subject to change without notice. Xcel Energy/Public Service Company of Colorado makes no warranty as to the accuracy or suitability of any information contained herein for use by third parties or for any particular purpose. The accuracy of this map and the information depicted should be verified prior to use. The user shall assume all risk and responsibility for any and all damages including consequential damages, which may arise from the user’s reliance on this information.

Project Study Area

Town Boundary

44 kV Existing Transmission

115 kV Existing Transmission

230 kV Existing Transmission

345 kV Existing Transmission

Existing Substation

Existing Cloverly Tap Point/Switch Gear

Planned 230 kV Transmission

Planned Husky Substation

Date: 10/11/2019

0 21

Miles

COUNTY RD 82COUNTY RD 82

COU

NTY

RD

43

COU

NTY

RD

43

COU

NTY

RD

43

COU

NTY

RD

43

COU

NTY

RD

33

COU

NTY

RD

33

COU

NTY

RD

33

COU

NTY

RD

33

COUNTY RD 74COUNTY RD 74

COUNTY RD 68COUNTY RD 68 COUNTY RD 68COUNTY RD 68

COUNTY RD 74COUNTY RD 74

CloverlySubstationCloverlySubstation