nbsm metrology

Embed Size (px)

Citation preview

  • 7/29/2019 nbsm metrology

    1/3

    Items to be purchased in Scientific Metrology Division, NBSM for FY-2069/70

    Prepared on March 4, 2013

    1/3

    Item I, Laptops

    Hard Drive : >500GB SATA 5400rpm

    Display: > 15.6 inch, Led

    Processor: > Intel 2nd Gen Core i5 , Speed - >2.3GhZ, Bus Speed : >1333 MHz

    Graphics Memory: 1GB

    Memory: > 4GB DDR3 Speed: >1333 MHz

    Hard Drive Capacity: > 500GB Serial ATA - 5400.0 rpm

    Operating System: Microsoft Windows 8 64 bit , Microsoft Windows 7 Professional 64 bit

    Network & Communication : WAN, Bluetooth, Ethernet, USB, HDMI

    Power: >6 hours

    Item 2, Low temperature liquid baths

    Temperature ranges from30C to 150C

    Stability to 0.02 C

    Uniformity: 0.05 CAccuracy: 0.3C

    Calibration Depth: not less than 300 mm

    Computer communications: USB /RS-232/LAN/WAN

    Item 3, Thermometric Bridge (For calibration of SPRTs, Thermistors etc)

    Measuring Range

    Temperature: -50 to 600 C ;

    Resistance: 0 to 400

    Resolution

    Temperature: 0.1 mK (Pt 100)Resistance: 50 m

    Measurement Uncertainty: Within the values of its resolution (95% Confidence Level & at (202)C

    Sensor Connection: 4 wire

    Number of sensor inputs: 2

    Computer communications: USB/RS-232/LAN/WAN

    (Calibration Certificates from laboratories accredited as per ISO/IEC 17025 required)

    Assumed Cost: $8000

    Item 4: Laboratory Ice Cube makers

    Required No. : 1

    Production Capacity >30 Kg/24 HoursStorage Capacity > 1 Year

    Accessories Ice Cube Crusher (Mechanical)

    Assumed Cost: $1000

    Item 5: Data Logger with humidity and temperature sensor : 1 set

  • 7/29/2019 nbsm metrology

    2/3

    Items to be purchased in Scientific Metrology Division, NBSM for FY-2069/70

    Prepared on March 4, 2013

    2/3

    Temperature:

    Thermistor Probe Measurement Range:40 C to 125 C (40 F to 257 F)

    Internal Resolution: 0.1 C typ

    Thermistor Probe Temperature Accuracy (Overall Error): 0.5 C typ, 2.0 C max

    Alarm Threshold Range (Software-Selectable):40 C to 125 C (40 F to 257 F) range for both high

    alarms and low alarms

    Data Sampling

    Sampling Rate (Software-Selectable): 10 s, 30 s, 1 min, 5 min, 30 min, 1 hr, 6 hr, 12 hr

    Temperature Samples: More than 1,000,000 max

    Temperature Units: C or F

    Relative Humidity

    Measurement Range: 0% RH to 100% RH

    Accuracy (Overall Error Between 20% RH and 80 %RH): 3.0% RH typ

    Alarm Threshold Range: 0% RH to 100% RH (high and low alarms)

    Data Sampling

    Sampling Rate (Software-Selectable): 10 s, 30 s, 1 min, 5 min, 30 min, 1 hr, 6 hr, 12 hr

    Combined Temperature and Humidity Samples: More than 500,000 maxTemperature Units: C or F

    Other requirements

    Rechargeable battery-powered:

    Internal lithium polymer battery (rechargeable using included microUSB cable)

    Internal Storage:

    Logs more than 1 million temperature samples and more than 500,000 temperature/humidity samples

    LCD Display:

    Integrated LCD screen displays current readings, min/max readings, high and low alarm occurrences,

    and battery charge status

    Connectivity: USB, WiFi

    Software

    Item 6: Force Transducer for Calibration of Universal testing machine/ Compressive testing

    machine (1 Set)

    Capacity: 2 MN

    Class : 0.5 (as per ISO 376)

    Direction of force: Tensile and Compression

    Protection: IP67

    Normal Sensitivity: 2mV/V

    Calibration Certificate: from ISO 17025 accredited Laboratory

    Other requirements: Mounting for tensile and compressive mode, display unit

    Item 6: Force Transducer for Calibration of Universal testing machine/ Compressive testing

    machine (1 Set)

    Capacity: 500kN

    Class : 0.5 (as per ISO 376)

    Direction of force: Tensile and Compression

    Protection: IP67

  • 7/29/2019 nbsm metrology

    3/3

    Items to be purchased in Scientific Metrology Division, NBSM for FY-2069/70

    Prepared on March 4, 2013

    3/3

    Normal Sensitivity: 2mV/V

    Calibration Certificate: from ISO 17025 accredited Laboratory

    Other requirements: Mounting for tensile and compressive mode, display unit