248
SECTION - 1L Incandescent Lighting Fixture

Nb cat

Embed Size (px)

Citation preview

Page 1: Nb cat

SECTION - 1L

Incandescent Lighting Fixture

Page 2: Nb cat

SECTION 1L

Incandescent Lighting Fixtures INDEX

Model

Lamp Type / Watt. Certification for Explosion-proof

PAGEIncandescent lampIEC UL

20 60 100 150 200 300

VDY ● ● 1L - 1

SYL ● ● Ex e II T1 1L - 4

EML ● ● Ex d IIB T3 1L - 7

EUL ● ● Ex d IIB T3 1L - 9

EULS ●Ex d IIB T4

Ex DP II 12 IP551L - 12

EFL ● ● ●Ex d IIC T3

Ex d IIC T5

Class I Division 1,2

Group C,D1L - 15

POLE TYPE Flameproof, Increased Safety, Vaportight Type Pole 1L -19

Page 3: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Incandescent Lighting Fixtures

VDY Series

Weathertight

NEMA 3, 3R, 5

Application Features Standard Materials

VDY Series lighting fixtures are used ;

in manufacturing plants,

refineries, chemical,

petrochemical and other industrial

process facilities, wastewater and

sewage treatment plants,

offshore, dockside and other

harbor installations as well as

other heavy industrial

applications.

wherever the damaging effects of

wind, snow, sleet, or hot sun are

found.

in marine applications where

water spray and corrosive

atmospheres are considerations.

in paint spray booth suitability

provides efficient, economical

HID lighting for paint spray

areas.

in industrial areas, both indoors

and outdoors where long life and

low maintenance costs are

desired.

in Industrial locations requiring

elevated ambient capability.

The lighting fixture has simple

construction.

The screw neck globe and the

guard are screwed on to the

body applying the reflector in its

position by the guard.

Synthetic rubber gasket is used

between the body and globe, so

that the lamp housing is sealed

against vapors and dusts.

Relamping is easily done by

opening lower half of the guard

and unscrewing the globe.

H.I.D lighting fixture has external

type ballast.

Body : Die casting aluminium

Globe : Heat resistant hard glass

Reflector : White coating

aluminium

Mounting Box : Cast aluminium

alloy

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color,

contact us please.

< VDY >

Certification

Certified by KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas Safety

Corporation), and the others.

Compliance Technical DataIP55 Electrical Ratings

Rated Voltage AC110V/ 220V/ 240V/ DC110V

Rated Wattage 100W/ 200W

Rated Frequency 50Hz/ 60Hz

Entry Sizes 1/2", 3/4", 1"

Weight

Mounting Type Catalog No. Weight

Ceiling (Small) VDY 2105 2.2 kg

Ceiling (Large) VDY 2205 4.5 kg

If you need more information, contact us please.⇨

Page 4: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number

Lamp Watt Hub Size Pendant Ceiling 90° Bracket 40° Bracket

Incandescent

Lamp

1001/2" VDY 1105 VDY 2105 VDY 3105 VDY 4105

3/4" VDY 1103 VDY 2103 VDY 3103 VDY 4103

2001/2" VDY 1205 VDY 2205 VDY 3205 VDY 4205

3/4" VDY 1203 VDY 2203 VDY 3203 VDY 4203

Ordering Information

V D Y 1 1 0 5 ① ② ③ ④

VDY Lighting Fixture① : Mounting Type② : Lamp Wattage (W)③ : Entry Size④

1 - Pendant 10 - 100 1 - 1"

2 - Ceiling 20 - 200 3 - 3/4"

3 - 90° Bracket 5 - 1/2"

4 - 40° Bracket

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

<VDY 2105> 0 145 50 130

5 135 55 115Lamp : IL100 (1250 lm)+

With Globe and Guard+

Reflector : +

White Coating Aluminum

Reflector

10 150 60 95.0

15 180 65 80.0

20 150 70 90.0

25 140 75 25.0

30 160 80 15.0

35 145 85 5.0

40 130 90 0.0

45 135

Coefficients of Utilization - Zonal Cavity

%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall

Reflectance(ρw)50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity Ratio

RCR20% Effective Floor Cavity Reflectance

0 .64 .64 .64 .63 .63 .63 .60 .60 .60 .57 .57 .57 .55 .55 .55 .54

1 .57 .55 .54 .56 .54 .53 .54 .52 .51 .52 .51 .50 .50 .49 .48 .47

2 .52 .49 .46 .51 .48 .45 .49 .46 .44 .47 .45 .43 .45 .44 .42 .41

3 .46 .43 .40 .46 .42 .39 .44 .41 .39 .43 .40 .38 .41 .39 .38 .36

4 .42 .38 .35 .41 .38 .35 .40 .37 .34 .39 .36 .34 .38 .35 .33 .32

5 .38 .34 .31 .38 .34 .31 .37 .33 .30 .36 .33 .30 .35 .32 .30 .29

6 .35 .31 .28 .34 .30 .28 .34 .30 .27 .33 .30 .27 .32 .29 .27 .26

7 .32 .28 .25 .32 .28 .25 .31 .27 .25 .30 .27 .25 .29 .27 .24 .23

8 .30 .26 .23 .29 .25 .23 .29 .25 .23 .28 .25 .22 .27 .24 .22 .21

9 .28 .24 .21 .27 .23 .21 .27 .23 .21 .26 .23 .21 .26 .23 .21 .20

10 .26 .22 .19 .25 .22 .19 .25 .22 .19 .24 .21 .19 .24 .21 .19 .18

Page 5: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Dimension

< VDY Pendant Type > < VDY 90° Bracket Type >

< VDY Ceiling Type > < VDY 40° Bracket Type >

Page 6: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Incandescent Lighting Fixtures

SYL Series

Wet Locations

NEMA 3, 3R, 4, 7

Type of Explosion-proof

< SYL >

Increase Safety (Ex e II T1)

Application

SYL Series lighting fixtures are used ;

in heavy process industries having environments

where flammable or explosive vapors or gases, or

where combustible dusts are present.

in hazardous areas, both indoors and outdoors where

long life and low maintenance costs are desired.

in petroleum refineries, chemical, petrochemical and

other heavy process industry facilities.

where ignitable concentrations of flammable gases,

vapors or liquids can exist all of the time or some of

the time under normal operation conditions.

Features Certification Standard Materials

The globe frame is cast in one

piece with guard.

The globe is sealed into the

globe frame firmly with

synthetic rubber gaskets, and

the globe assembly is fitted to

the body by three socket head

captive screws.

All joint of lamp housing,

including the joint between the

top body and the terminal

plate, are sealed up with high

quality gaskets so as to restrict

breathing.

Certified by KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas

Safety Corporation), and the

others.

Enclosure : Aluminium sheet

Globe : Heat resistant hard glass

Globe Frame : Die casting aluminium

Mounting Box : Cast aluminium alloy

External Hardware :

Stainless steel

Compliance Standard Finish

NEMA 3 ,3R, 4, 7

IEC 60079-0, 1

IP55

MUNSELL No. 7.5BG 6/1.5

If you want another color, contact us

please.

Technical DataWeightElectrical Rating

Rated Voltage AC110V/ 220V/ 240V/ DC110V Mounting Type Catalog No. Weight

Rated Wattage 100W/ 200WCeiling SYL 2105 3.9 Kg

Entry Size 1/2", 3/4", 1"

If you need more information, contact us please. ⇨

Page 7: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

<SYL 2205> 0 137.0 50 132.7

5 143.4 55 149.8Lamp : IL200 (2920 lm)+

With Globe and Guard+ 10 149.8 60 102.7

15 128.4 65 98.5

20 134.9 70 34.2

25 137.0 75 15.0

30 107.0 80 6.4

35 107.0 85 4.3

40 102.7 90 2.2

45 111.3

Coefficients of Utilization - Zonal Cavity

%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall

Reflectance(ρw)50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity Ratio

RCR20% Effective Floor Cavity Reflectance

0 .62 .62 .62 .60 .60 .60 .58 .58 .58 .55 .55 .55 .53 .53 .53 .52

1 .55 .53 .51 .54 .52 .51 .52 .50 .49 .50 .49 .47 .48 .47 .46 .45

2 .49 .46 .44 .48 .45 .43 .46 .44 .42 .45 .43 .41 .43 .42 .40 .39

3 .44 .40 .37 .43 .40 .37 .42 .39 .36 .40 .38 .36 .39 .37 .35 .34

4 .40 .35 .32 .39 .35 .32 .38 .34 .32 .36 .34 .31 .35 .33 .31 .30

5 .36 .31 .28 .35 .31 .28 .34 .31 .28 .33 .30 .28 .32 .29 .27 .26

6 .32 .28 .25 .32 .28 .25 .31 .27 .25 .30 .27 .24 .29 .26 .24 .23

7 .29 .25 .22 .29 .25 .22 .28 .25 .22 .28 .24 .22 .27 .24 .22 .21

8 .27 .23 .20 .27 .23 .20 .26 .22 .20 .25 .22 .20 .25 .22 .20 .19

9 .25 .21 .18 .25 .21 .18 .24 .21 .18 .23 .20 .18 .23 .20 .18 .17

10 .23 .19 .17 .23 .19 .17 .22 .19 .17 .22 .19 .16 .21 .18 .16 .16

Ordering Number

Lamp WattHub

SizePendant Ceiling 90° Bracket 40° Bracket Certification

Incandescent

Lamp

1001/2" SYL 1105 SYL 2105 SYL 3105 SYL 4105

Ex e II T13/4" SYL 1103 SYL 2103 SYL 3103 SYL 4103

2001/2" SYL 1205 SYL 2205 SYL 3205 SYL 4205

3/4" SYL 1203 SYL 2203 SYL 3203 SYL 4203

Ordering Information

S Y L 1 1 0 5 ① ② ③ ④

SYL Lighting Fixture① ② Mounting Type Lamp Wattage (W)③ Entry Size④

1 - Pendant 10 - 100 1 - 1"

2 - Ceiling 20 - 200 3 - 3/4"

3 - 90° Bracket 5 - 1/2"

4 - 40° Bracket

Page 8: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Dimension

< SYL Ceiling Type > < SYL Pendant Type >

< SYL 90° Bracket Type > < SYL 40° Bracket Type >

Page 9: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Incandescent Lighting Fixtures

EML Series

Wet Locations

NEMA 3, 3R, 7

<EML 8024>

Type of Explosion-proof Flameproof (Ex d IIB T3)

Application

EML Series incandescent lighting fixtures are used ;

for flush or surface mounting on ceiling, wall or

pedant in conduit systems.

in hazardous areas, both indoors and outdoors where

enclosed and gasketed fixtures are required.

in tunnels, building entrances and similar locations,

where moisture, dirt, chemicals, vibration or rough

usage are a problem.

where ignitable concentrations of flammable gases,

vapors, liquids or dusts can exist some of the time

under normal operating conditions.

Features Designed to exclude dirt, moisture and corrosive

vapors from the interior of the fixtures and the

conduit system.

The globe-guard assembly in installed and removed

as a unit making it necessary to handle only one

piece in relamping.

All fixtures are rugged and corrosion-resistant.

Standard Materials

Enclosure : Cast aluminium alloy

Globe : Heat resistant hard glass

Globe Ring : Cast aluminium alloy

Guard : Stainless steel wire

Compliance IEC 60079-0, 1

NEMA 3, 3R, 7

IP 55

CertificationCertified by KOSHA (Korea Occupational Safety &

Health Agency), KGS (Korea Gas Safety Corporation),

and the others.

Weight

Mounting Type Catalog No. Weight

Ceiling EML 8024 4.7 Kg

Standard Finish Technical Data

MUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

Electrical Rating

Rated VoltageAC110V/ 220V/ 240V

DC110V

Rated Wattage 100W/ 150W/ 200W/ 300WOptionsEntry Size 1/2", 3/4", 1"

Guard : Stainless steel

Reflector : Aluminium Dome Reflector

Aluminium 30° Angle Reflector

Pole type pendant

* Atmosphere Temp : -20 ~ 55℃ ℃

Ordering Number

Lamp Watt Pendant Ceiling Bracket Certification

Incandescent Lamp

100 EML 8011 EML 8021 EML 8031

Ex d IIB T3150 EML 8014 EML 8024 EML 8034

200 EML 8012 EML 8022 EML 8032

300 EML 8013 EML 8023 EML 8033

* For Pole type, see pole section (1L-19)

If you need more information, contact us please. ⇨

Page 10: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

<EML 8021> 0 75 50 130

5 76 55 132Lamp : IL100 (1250 lm)+

With Globe and+

without Guard

10 80 60 139

15 88 65 143

20 92 70 147

25 101 75 151

30 111 80 150

35 118 85 150

40 126 90 150

45 129

Coefficients of Utilization - Zonal Cavity%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall

Reflectance(ρw)50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity Ratio

RCR20% Effective Floor Cavity Reflectance

0 .88 .88 .88 .86 .86 .86 .82 .82 .82 .78 .78 .78 .75 .75 .75 .74

1 .74 .70 .66 .72 .68 .65 .69 .66 .63 .66 .63 .61 .63 .61 .59 .57

2 .62 .55 .50 .60 .54 .49 .57 .52 .48 .55 .51 .47 .52 .49 .46 .44

3 .52 .45 .39 .51 .44 .39 .49 .43 .38 .47 .42 .37 .45 .40 .37 .35

4 .45 .38 .32 .44 .37 .32 .42 .36 .31 .40 .35 .31 .39 .34 .30 .28

5 .40 .32 .27 .39 .32 .26 .37 .31 .26 .36 .30 .26 .34 .29 .25 .24

6 .35 .28 .23 .35 .28 .23 .33 .27 .22 .32 .26 .22 .31 .26 .22 .20

7 .32 .25 .20 .31 .24 .20 .30 .24 .19 .29 .23 .19 .28 .23 .19 .17

8 .29 .22 .17 .28 .22 .17 .27 .21 .17 .26 .21 .17 .26 .21 .17 .15

9 .27 .20 .15 .26 .20 .15 .25 .19 .15 .24 .19 .15 .24 .19 .15 .14

10 .30 .24 .20 .29 .24 .20 .29 .24 .20 .28 .23 .20 .27 .23 .20 .19

Dimension

<EML Ceiling Type> < EML Pendant Type > < EML Bracket Type>

Page 11: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Incandescent Lighting Fixtures

EUL Series

Wet Locations

Factory Sealed

NEMA 3, 3R, 7

Type of Explosion-proof

Flameproof (Ex d IIB T3)

<EUL 3021>

Features

The body is cast in one piece,

and the upper part of which

forms a terminal chamber.

Globe assembly is securely

hinged to the body.

Mounting box has four-way

conduit entries and a large

access cover for wiring.

The globe holder is fixed to the

base of the body with special

flameproof and weatherproof

flanged joint.

The guard is so constructed that

can be hinged down for

cleaning the globe.

Application

EUL Series lighting fixtures are used ;

in tunnels, building entrances and

similar locations where moisture,

dirt, chemicals or rough usage are

a problem.

in heavy process industries having

environments where flammable or

explosive vapors or gases, or where

combustible dusts are present.

in areas where combustible dusts

and flammable vapors are present

simultaneously.

in hazardous areas, both indoors

and

outdoors where long life and low

maintenance costs are desired.

where high light output is needed

but space is limited.

where ignitable concentrations of

flammable gases, vapors, liquids or

dusts can exist some of the time

under normal operating conditions.

Compliance

IEC 60079-0, 1

NEMA 3, 3R, 7

IP 55

Certification

Certified by KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas Safety

Corporation), and the others.

Standard Materials Standard Finish

Enclosure : Die casting aluminium

Globe : Heat resistant hard glass

Inner Reflector : High purity aluminium

External Hardware : Stainless steel

Mounting Box : Cast aluminium alloy

MUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

Technical Data Weight

Electrical Rating Mounting Type Catalog No. Weight

Rated Voltage AC110V/ 220V/ 240V/ DC110V Ceiling EUL 3022 3.7 ㎏

Rated Wattage 100W/ 200W

Rated Frequency 50Hz/ 60Hz

Entry Size 1/2", 3/4", 1"

If you need more information, contact us please. ⇨

Page 12: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number

Lamp Watt Pendant Ceiling 90° Bracket 40° Bracket Certification

Incandescent Lamp100 EUL 3011 EUL 3021 EUL 3031 EUL 3041

Ex d IIB T3200 EUL 3012 EUL 3022 EUL 3032 EUL 3042

* For Pole type, see pole section (1L-19)

Ordering Information Temperature Performance Data

E U L 3 0 2 1 Lamp Ambient Flameproof Dust-Ignition

① ② ③ Type Watt. Temp ( )℃ "d" "DP"

EUL Lighting Fixture① Mounting Type②

Incandescent

10040 T4 11

1 - Pendant 55 T3 -

Wattage (W)③ 2 - Ceiling200

40 T4 11

1 - 100 3 - 90° Bracket 55 T3 -

2 - 200 4 - 40° Bracket

Dimension

<Ceiling Type> <Pendant Type> <90° Bracket Type > <40° Bracket Type >

Page 13: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Photometric Data

Angle /1000㏅ ㏐ Angle /1000㏅ ㏐

<EUL 3021> 0 167 50 133

5 180 55 132Lamp : IL100 (1250lm)+

With Guard+ 10 138 60 158

15 140 65 119

20 136 70 120

25 146 75 107

30 175 80 91.8

35 171 85 27.7

40 162 90 10.1

45 153

Coefficients of Utilization - Zonal Cavity%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance

0 .87 .87 .87 .85 .85 .85 .81 .81 .81 .78 .78 .78 .75 .75 .75 .73

1 .76 .73 .70 .74 .71 .69 .71 .69 .67 .68 .66 .65 .66 .64 .63 .61

2 .67 .62 .57 .65 .61 .57 .63 .59 .55 .60 .57 .54 .58 .55 .53 .51

3 .59 .53 .48 .57 .52 .47 .55 .50 .47 .53 .49 .46 .51 .48 .45 .43

4 .52 .46 .41 .51 .45 .40 .49 .44 .40 .47 .43 .39 .46 .42 .39 .37

5 .46 .40 .35 .46 .39 .35 .44 .39 .35 .43 .38 .34 .41 .37 .34 .32

6 .42 .35 .31 .41 .35 .31 .40 .34 .30 .39 .34 .30 .38 .33 .30 .28

7 .38 .32 .27 .38 .32 .27 .36 .31 .27 .35 .30 .27 .34 .30 .27 .25

8 .35 .29 .25 .34 .29 .24 .33 .28 .24 .33 .28 .24 .32 .27 .24 .23

9 .32 .26 .22 .32 .26 .22 .31 .26 .22 .30 .25 .22 .29 .25 .22 .21

10 .30 .24 .20 .29 .24 .20 .29 .24 .20 .28 .23 .20 .27 .23 .20 .19

Angle /1000㏅ ㏐ Angle /1000㏅ ㏐

<EUL 3022> 0 172 50 83.8

5 157 55 85.3Lamp : IL200 (2920lm)+

With Guard+ 10 166 60 70.7

15 152 65 82.1

20 138 70 92.5

25 143 75 84.6

30 127 80 78.3

35 103 85 79.2

40 92.5 90 95.4

45 87.9

Coefficients of Utilization - Zonal Cavity%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance

0 .70 .70 .70 .69 .69 .69 .66 .66 .66 .63 .63 .63 .60 .60 .60 .59

1 .60 .57 .54 .59 .56 .54 .56 .54 .52 .54 .52 .50 .52 .50 .49 .47

2 .52 .47 .43 .50 .46 .43 .48 .45 .42 .46 .43 .41 .44 .42 .40 .38

3 .45 .40 .36 .44 .39 .35 .42 .38 .35 .41 .37 .34 .39 .36 .33 .32

4 .40 .34 .30 .39 .34 .30 .38 .33 .30 .36 .32 .29 .35 .32 .29 .27

5 .36 .30 .26 .35 .30 .26 .34 .29 .26 .33 .29 .26 .32 .28 .25 .24

6 .33 .27 .23 .32 .27 .23 .31 .26 .23 .30 .26 .23 .29 .25 .23 .21

7 .30 .25 .21 .29 .24 .21 .29 .24 .21 .28 .24 .21 .27 .23 .20 .19

8 .28 .23 .19 .27 .22 .19 .26 .22 .19 .26 .22 .19 .25 .21 .19 .18

9 .26 .21 .18 .25 .21 .17 .25 .20 .17 .24 .20 .17 .23 .20 .17 .16

10 .24 .19 .16 .24 .19 .16 .23 .19 .16 .23 .19 .16 .22 .19 .16 .15

Page 14: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Incandescent / Compact Fluorescent

Lighting Fixtures

EULS Series

Wet Locations

Factory Sealed

NEMA 3, 3R, 7

Type of Explosion-proof

Flameproof (Ex d IIB T4)

Dust Ignition-proof (Ex DP II 12 IP55)

Application Features

EULS Series lighting fixtures are used ;

in tunnels, building entrances

and similar locations where

moisture, dirt, chemicals or

rough usage are a problem.

in heavy process industries

having environments where

flammable or explosive vapors or

gases, or where combustible

dusts are present.

in areas where combustible

dusts and flammable vapors are

present simultaneously.

in hazardous areas, both indoors

and outdoors where long life

and low maintenance costs are

desired.

where high light output is

needed but space is limited.

where ignitable concentrations of

flammable gases, vapors, liquids

or dusts can exist some of the

time under normal operating

conditions.

< EULS >

Globe assembly is securely

hinged to the body.

Mounting box has four-way

conduit entries and a large

access opening cover for wiring.

Standard Materials

Enclosure :

Die casting aluminium

Globe :

Heat resistant hard glass

Inner Reflector :

High purity aluminium

External Hardware :

Stainless steel

Mounting Box : Cast aluminium

alloy

Compliance & Certification Standard Finish

Certified by KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas Safety

Corporation), and the others.

IEC 60079- 0.1

NENA 3.3R.7

MUNSELL No. 7.5BG 6/1.5

If you want another color,

contact us please.

Technical Data Weight

Electrical Rating Mounting Type Catalog No. Weight

Rated Voltage AC110V/ 220V/ 240V/ DC110V Ceiling EULS 3021 2.8 ㎏

Rated Wattage IL 100W/ CFL 20W

Rated Frequency 50Hz/ 60Hz

Entry Size 1/2", 3/4", 1"

If you need more information, contact us please. ⇨

Page 15: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number

Lamp Watt Pendant Ceiling90°

Bracket

40°

BracketCertification

Incandescent Lamp 100 EULS 3021 Ex d IIB T4

Compact Self Ballast Fluorescent Lamp 20 EULS 3022 Ex DP II 12

* Pendant , 90° and 40° Bracket types are order-made items.

Ordering Information Temperature Performance Data

E U LS 3 0 2 1 Lamp Ambient Flameproof Dust-Ignition

① ② ③ ④ Type Watt. Temp ( )℃ "d" "DP"

, EULS Lighting Fixture① ② Watt④ Incandescent 100

40 T4 -

0 - 20 55 - -

Mounting Type③ 1 - 100 Compact

Fluorescent20

40 T5 12

1 - Pendant 55 - -

2 - Ceiling

3 - 90° Bracket

4 - 40° Bracket

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

<EULS 3021> 0 124 50 109

5 108 55 139Lamp : IL 100 (1250 )+ ㏐

With Globe and Guard+ 10 96.5 60 131

15 128 65 123

20 126 70 128

25 124 75 107

30 118 80 66.8

35 111 85 19.6

40 128 90 10.8

45 124

Coefficients of Utilization - Zonal Cavity%Effective Ceiling

Cavity

Reflectance( cc)ρ

80 70 50 30 10 0

%Wall

Reflectance(ρw)50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity Ratio

RCR20% Effective Floor Cavity Reflectance

0 .77 .77 .77 .76 .76 .76 .72 .72 .72 .69 .69 .69 .66 .66 .66 .65

1 .68 .65 .63 .66 .64 .62 .64 .61 .60 .61 .59 .58 .59 .57 .56 .55

2 .59 .55 .51 .58 .54 .50 .55 .52 .49 .53 .50 .48 .51 .49 .47 .45

3 .52 .46 .42 .51 .46 .42 .49 .44 .41 .47 .43 .40 .45 .42 .39 .38

4 .45 .40 .35 .45 .39 .35 .43 .38 .34 .41 .37 .34 .40 .36 .34 .32

5 .40 .35 .30 .40 .34 .30 .38 .33 .30 .37 .33 .29 .36 .32 .29 .28

6 .36 .30 .26 .36 .30 .26 .35 .30 .26 .33 .29 .26 .32 .28 .25 .24

7 .33 .27 .23 .32 .27 .23 .31 .26 .23 .30 .26 .23 .29 .25 .22 .21

8 .30 .24 .21 .30 .24 .20 .29 .24 .20 .28 .23 .20 .27 .23 .20 .19

9 .28 .22 .19 .27 .22 .18 .26 .22 .18 .26 .21 .18 .25 .21 .18 .17

10 .26 .20 .17 .25 .20 .17 .25 .20 .17 .24 .20 .17 .23 .19 .17 .15

Page 16: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Angle cd/1000 lm Angle cd/1000 lm

<EULS 3022> 0 47.8 50 94.2

5 48.5 55 97.7Lamp : CFL20 (1200 )+ ㏐

With Globe and Guard+ 10 49.3 60 99.9

15 51.3 65 101

20 56.3 70 102

25 61.8 75 101

30 70.3 80 98.4

35 78.0 85 94.2

40 83.7 90 90.7

45 89.4

Coefficients of Utilization - Zonal Cavity%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance

0 .67 .67 .67 .66 .66 .66 .63 .63 .63 .60 .60 .60 .57 .57 .57 .56

1 .56 .54 .51 .55 .52 .50 .53 .50 .48 .50 .49 .47 .48 .47 .45 .44

2 .47 .43 .39 .46 .42 .38 .44 .40 .37 .42 .39 .36 .40 .38 .35 .34

3 .40 .35 .30 .39 .34 .30 .37 .33 .29 .36 .32 .29 .34 .31 .28 .27

4 .35 .29 .24 .34 .29 .24 .32 .28 .24 .31 .27 .24 .30 .26 .23 .22

5 .30 .25 .20 .30 .24 .20 .29 .24 .20 .27 .23 .20 .26 .22 .19 .18

6 .27 .21 .17 .27 .21 .17 .25 .21 .17 .24 .20 .17 .23 .20 .17 .15

7 .24 .19 .15 .24 .19 .15 .23 .18 .15 .22 .18 .15 .21 .17 .14 .13

8 .22 .17 .13 .22 .17 .13 .21 .16 .13 .20 .16 .13 .19 .16 .13 .12

9 .20 .15 .12 .20 .15 .12 .19 .15 .11 .18 .14 .11 .18 14 .11 .10

10 .18 .14 .10 .18 .13 .10 .18 .13 .10 .17 .13 .10 .16 .13 .10 .09

Dimension

< Ceiling Type>

Page 17: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Incandescent Lighting Fixtures

EFL Series

Wet Locations

Factory Sealed

NEMA 3, 3R, 7

Type of Explosion-proof

Class I Division 1,2 Group C,D

Flameproof (Ex d IIC T3)Features

Application

<EFL 6021>

Factory sealed - no external seal

required

Easy to assemble and relamping

Light weight

Corrosion resistant

Inner reflector eliminates upward

spill light

EFL Series lighting fixtures are used ;

in locations which are hazardous

due to the presence of

flammable vapors or gases and

where dampness or corrosion are

present.

as pendant, ceiling, wall bracket

or bulkhead fixtures, indoor for

general area or room lighting and

outdoor for spot lighting.

Standard Materials

Enclosure :

Die casting aluminium

Globe : Heat resistant hard glass

Inner Reflector :

Extra pure aluminium

Guard : Die casting aluminium

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color,

contact us please.

Certification Compliance

UL Listed File No. E 131747

Certified by UL (Underwriters Laboratories Inc.),

KOSHA (Korea Occupational Safety & Health

Agency), KGS (Korea Gas Safety Corporation), and

the others.

NEC - Class I Division 1,2 Group C,D,

UL 844 - Lighting Fixtures for Use in Hazardous

(Classified) Locations

IEC 60079-0, 1

NEMA 3, 3R, 7

IP 55

Technical Data Weight

Electrical Rating Mounting Type Catalog No. Weight

Rated Voltage Max. 240V (120V/ 220V for UL Listed) Pendant EFL 6011 5.3 ㎏

Rated Wattage 100W/ 200W/ 300W Ceiling EFL 6021 5.2 ㎏

Rated Frequency 50Hz/ 60Hz Bulkhead EFL 6043 7.3 ㎏

Entry Size 1/2", 3/4", 1" Bracket EFL 6033 8.1 ㎏

Ordering Number

Lamp Watt Pendant Ceiling Bracket Bulkhead Certification

Incandescent

100 EFL 6011 EFL 6021 EFL 6031 EFL 6041

Class I Division 1,2 Group C,D

Ex d IIC T3200 EFL 6012 EFL 6022 EFL 6032 EFL 6042

300 EFL 6013 EFL 6023 EFL 6033 EFL 6043

If you need more information, contact us please ⇨

Page 18: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Information Temperature Performance Data

E F L 6 0 1 1 Lamp Ambient Class I Flameproof

① ② ③ ④ Type Watt. Temp ( )℃ Group C,D "d"

Incandes

cent

10040 120 (T4A) T3

EFL Lighting Fixture① Mounting Type③ Watt④ 55 - -

1 - Pendant 1 - 100200

40 160(T3C) / 120(T4A)* T3

Lamp Type② 2 - Ceiling 2 - 200 55 - -

60 - Incandescent 3 - Bracket 3 - 300300

40 160 (T3C) T3

4 - Bulkhead 55 - -

* are when use 300W body

Dimension

<Ceiling Type>

<Bracket Type>

<Bulkhead Type>

<Pendant Type>

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

<EFL 6013> 0 124 50 86.8

5 118 55 92.7Lamp : IL300 (4278 lm)+

With Guard+ 10 112 60 94.6

15 108 65 98.6

20 96.7 70 104

25 90.7 75 86.8

30 80.9 80 82.9

35 74.9 85 80.9

40 73.0 90 78.8

45 77.0

Coefficients of Utilization - Zonal Cavity%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance

0 .66 .66 .66 .64 .64 .64 .61 .61 .61 .59 .59 .59 .56 .56 .56 .55

1 .56 .53 .50 .54 .52 .49 .52 .50 .48 .50 .48 .46 .48 .46 .45 .44

2 .47 .43 .39 .46 .42 .38 .44 .41 .38 .42 .39 .37 .40 .38 .36 .34

3 .41 .35 .31 .40 .35 .31 .38 .34 .30 .36 .33 .30 .35 .32 .29 .28

4 .35 .30 .26 .35 .30 .26 .33 .29 .25 .32 .28 .25 .31 .27 .25 .23

5 .31 .26 .22 .31 .26 .22 .30 .25 .22 .28 .24 .21 .27 .24 .21 .20

6 .28 .23 .19 .28 .23 .19 .27 .22 .19 .26 .22 .19 .25 .21 .18 .17

7 .26 .20 .17 .25 .20 .17 .24 .20 .17 .23 .19 .16 .23 .19 .16 .15

8 .23 .18 .15 .23 .18 .15 .22 .18 .15 .22 .18 .15 .21 .17 .15 .14

9 .22 .17 .14 .21 .17 .14 .21 .16 .13 .20 .16 .13 .19 .16 .13 .12

10 .20 .15 .12 .20 .15 .12 .19 .15 .12 .19 .15 .12 .18 .15 .12 .11

Page 19: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Compact Fluorescent Lighting Fixtures

EFL Series

Wet Locations

Factory Sealed

NEMA 3, 3R, 7

Type of Explosion-proof

Flameproof (Ex d IIC T5)

<EFL 7014>

Features

Factory sealed - no external seal

required

Easy to assemble and relamping

Light weight

Corrosion resistant

Inner reflector eliminates upward

spill light

Use compact fluorescent lamp 20W

instead of incandescent lamp.

Application

EFL Series lighting fixtures are used ;

in locations which are hazardous

due to the presence of flammable

vapors or gases and where

dampness or corrosion are

present.

as pendant, ceiling, wall bracket

or bulkhead fixtures, indoor for

general area or room lighting and

outdoor for spot lighting.Standard Materials

Enclosure :

Die casting aluminium

Globe : Heat resistant hard glass

Inner Reflector :

Extra pure aluminium

Guard : Die casting aluminium

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color, contact

us please.

Certification Compliance

Certified by KOSHA (Korea

Occupational Safety & Health

Agency), KGS(Korea Gas Safety

Corporation), and the others.

IEC 60079-0, 1

NEMA 3, 3R, 7

IP 55

Technical Data Weight

Electrical Rating Mounting Type Catalog No. Weight

Rated Voltage Max. AC240V Pendant EFL 7014 5.3 ㎏

Rated Wattage Compact Fluorescent 20W

Rated Frequency 50Hz/ 60Hz

Entry Size 1/2", 3/4", 1"

Ordering Number

Lamp Watt Pendant Ceiling Bracket Bulkhead Certification

Compact Fluorescent 20 EFL 7014 EFL 7024 EFL 7034 EFL 7044 Ex d IIC T5

If you need more information, contact us please. ⇨

Page 20: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Information Temperature Performance Data

E F L 7 0 1 4 Lamp Ambient Flameproof

① ② ③ ④ Type Watt. Temp ( )℃ "d"

Compact

Fluorescent20

40 T5

EFL Lighting Fixture① Mounting Type③ Watt : 4 - 20④ 55 -

1 - Pendant

Lamp Type② 2 - Ceiling

70 - Compact Fluorescent 3 - Bracket

4 - Bulkhead

Dimension

<Ceiling Type>

<Bracket Type>

<Bulkhead Type>

<Pendant Type>

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

0 63.3 50 86.5<EFL 7014>

5 63.3 55 92.2Lamp : CFL20 (1200 lm)+

With Guard+ 10 64.0 60 98.4

15 65.3 65 101

20 71.8 70 104

25 78.7 75 108

30 80.2 80 104

35 78.0 85 99.9

40 76.7 90 92.9

45 80.2

▞Coefficients of Utilization - Zonal Cavity%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance

0 .69 .69 .69 .67 .67 .67 .64 .64 .64 .62 .62 .62 .59 .59 .59 .58

1 .58 .55 .52 .57 .54 .51 .54 .52 .50 .52 .50 .48 .50 .48 .47 .45

2 .48 .44 .39 .47 .43 .39 .45 .41 .38 .43 .40 .37 .41 .39 .36 .35

3 .41 .35 .31 .40 .35 .31 .38 .34 .30 .37 .33 .29 .35 .32 .29 .27

4 .36 .30 .25 .35 .29 .25 .33 .28 .25 .32 .28 .24 .30 .27 .24 .22

5 .31 .25 .21 .31 .25 .21 .29 .24 .21 .28 .24 .20 .27 .23 .20 .19

6 .28 .22 .18 .27 .22 .18 .26 .21 .18 .25 .21 .17 .24 .20 .17 .16

7 .25 .20 .16 .25 .19 .15 .24 .19 .15 .23 .18 .15 .22 .18 .15 .14

8 .23 .17 .14 .22 .17 .14 .22 .17 .14 .21 .17 .13 .20 .16 .13 .12

9 .21 .16 .12 .21 .16 .12 .20 .15 .12 .19 .15 .12 .19 .15 .12 .11

10 .19 .14 .11 .19 .14 .11 .18 .14 .11 .18 .14 .11 .17 .14 .11 .10

Page 21: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Incandescent Lighting Fixtures Pole Type

Explosion proof & Vaportight

Weathertight

NEMA 3, 3R, 5

Lighting

FixturesConstruction

Lamp

Watt

Catalog Number

Hand Rail Type Pedestal Type

2.5M Height 3.5M Height 2.5M Height 3.5M Height

EFLP Series

Flameproof

Ex d IIB T3

CL I,

GR C,D

60 EFLP 60906-25H EFLP 60906-35H EFLP 60906-25P EFLP 60906-35P

100 EFLP 60910-25H EFLP 60910-25H EFLP 60910-25H EFLP 60910-35H

200 EFLP 60920-25H EFLP 60920-25H EFLP 60920-25H EFLP 60920-35H

EULP SeriesFlameproof

Ex d IIB T4

60 EULP 30906-25H EULP 30906-35H EULP 30906-25P EULP 30906-35P

100 EULP 30910-25H EULP 30910-35H EULP 30910-25H EULP 30910-35H

200 EULP 30920-25H EULP 30920-35H EULP 30920-25H EULP 30920-35H

SYLP Series

Increased

Safety

Ex e II T1

60 SYLP 70906-25H SYLP 70906-35H SYLP 70906-25P SYLP 70906-35P

100 SYLP 70910-25H SYLP 70910-35H SYLP 70910-25P SYLP 70910-35P

200 SYLP 70920-25H SYLP 70920-35H SYLP 70920-25P SYLP 70920-35P

VDYP SeriesVapor Tight

IP 54

60 VDYP 10906-25H VDYP 10906-35H VDYP 10906-25P VDYP 10906-35P

100 VDYP 10910-25H VDYP 10910-35H VDYP 10910-25P VDYP 10910-35P

200 VDYP 10920-25H VDYP 10920-35H VDYP 10920-25P VDYP 10920-35P

Features

These pole type fittings are the combinations of lighting units for Flameproof EFLP, EULP series, Increase safety

SYLP series or Vapor tight VDYP series incandescent lighting fittings and goose neck shaped poles.

These fittings are mainly used for tower illumination of chemical plant.

Additionally, fixing and wiring connection of these fittings are recommended to be done with Flameproof EOB or

Increased safety and Heavy duty SBD junction boxes in compliance with the type of protection of lighting units.

Other height not listed in the catalog are also available on request.

Conduit entry-Three(3)-28(1")max. Specify the position and size when ordering.

If you need more information, contact us please. ⇨

Page 22: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Dimension

< Hand Rail Type >

* Length (L) is order made.

(Standard is 2.5M, 3.5M. See front page)

< Pedestal Type >

Page 23: Nb cat

SECTION - 2L

HID Lighting Fixture

Page 24: Nb cat

SECTION 2L

H.I.D Lighting Fixtures INDEX

Model

Lamp Type / Watt.Certification for Explosion-proof

PAGEHigh Pressure Sodium Mercury Vapor Metal Halide

50 70 100 150 200 250 400 100 200 250 400 100 175 250 400 IEC UL

VD ● ● ● ● ● ● ● ● 2L - 1

VS ● ● ● ● ● ● ● ● ● ● ● ● ● 2L - 4

SR ● ● ● ● ● ● ● ● ● ● ● ● ● Ex nR II T3 2L - 7

VG ● ● ● ● ●

Ex nR II T4 IP66

Ex DP II 11

Class I

Division 2

Group A,B,C,D

Class II

Division 1,2

Group E,F,G

Class III

Division 1

2L - 12

VN ● ● ● ● ● ● ● 2L - 15

VZ ● ● ● ● ● ● 2L - 19

AUXILIARY H.I.D AUXILIARY LIGHTING 2L - 23

EVN ● ● ● ● ● ● ●

Ex dnR IIC T4

Ex nR II T4 IP66

Ex DP II 11 IP66

2L - 24

EU ● ● ● ● ●Ex d IIB T4

Ex DP II 122L - 30

EA ● ● ● ● ● ● ●Ex d IIC T4

Ex d IIB T42L - 33

EVS ● ● ● ● ● ● ● ● ● ● Ex de IIC T3 2L - 39

EGS ● ● ● ● ●Ex d IIC T4

Ex DP II 122L - 43

EG ● ● ● ● ● ● ● ● ● ● Ex d IIC T3Class I Division

1 Group C,D2L - 46

POLE TYPE Flameproof, Increased Safety, Vaportight Pole Type 2L - 51

SB HID Ballast 2L - 53

Accessary Globe, Guard, Reflector 2L - 55

Page 25: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

H.I.D Lighting Fixtures

VD Series

Weathertight

NEMA 3, 3R, 5

Application Features Standard Materials

VD Series lighting fixtures are used ;

in manufacturing plants, refineries,

chemical, petrochemical and

other industrial process facilities,

wastewater and sewage

treatment plants, offshore,

dockside and other harbor

installations as well as other heavy

industrial applications.

wherever the damaging effects of

wind, snow, sleet, or hot sun are

found.

in marine applications where

water spray and corrosive

atmospheres are considerations.

in paint spray booth suitability

provides efficient, economical

HID lighting for paint spray

areas.

in Industrial areas, both indoors

and outdoors where long life and

low maintenance costs are

desired.

in industrial locations requiring

elevated ambient capability.

The lighting fixture has simple

construction.

The screwneck globe and the

guard are screwed on to the

body applying the reflector in

its position by the guard.

Synthetic rubber gasket is

used between the body and

globe, so that the lamp

housing is sealed against

vapors and dusts.

Relamping is easily done by

opening lower half of the

guard and unscrewing the

globe.

H.I.D lighting fixture has

external type ballast.

Body : Die casting aluminium

Globe : Heat resistant hard glass

Reflector : White coating aluminium

Mounting Box : Cast aluminium

alloy

Certification

Certified by KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas Safety

Corporation), and the others.

Compliance

IP55

< VD >

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color,

contact us please.

Technical Data Weight

Electrical Ratings Mounting Type Catalog No. Weight

Rated Voltage AC110V/ 220V/ 240V/ DC110V Ceiling (Small) VDNY 32075 8.7 Kg

Ceiling (Large) VDNY 32155 15.5 KgRated Wattage 70W/ 100W/ 150W/ 175W/ 200W

Rated Frequency 50Hz/ 60Hz

Entry Sizes 1/2", 3/4", 1"

Also you can order various voltage : ※

120V/ 208V/ 277V/ 460V

If you need more information, contact us please. ⇨

Page 26: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number

Lamp Watt Hub Size Pendant Ceiling 90° Bracket 40° Bracket

High

Pressure

Sodium

701/2" VDNY 31075 VDNY 32075 VDNY 33075 VDNY 34075

3/4" VDNY 31073 VDNY 32073 VDNY 33073 VDNY 34073

1001/2" VDNY 31105 VDNY 32105 VDNY 33105 VDNY 34105

3/4" VDNY 31103 VDNY 32103 VDNY 33103 VDNY 34103

1501/2" VDNY 31155 VDNY 32155 VDNY 33155 VDNY 34155

3/4" VDNY 31153 VDNY 32153 VDNY 33153 VDNY 34153

2001/2" VDNY 31205 VDNY 32205 VDNY 33205 VDNY 34205

3/4" VDNY 31203 VDNY 32203 VDNY 33203 VDNY 34203

Metal

Halide

1001/2" VDHY 31105 VDHY 32105 VDHY 33105 VDHY 34105

3/4" VDHY 31103 VDHY 32103 VDHY 33103 VDHY 34103

1751/2" VDHY 31175 VDHY 32175 VDHY 33175 VDHY 34175

3/4" VDHY 31173 VDHY 32173 VDHY 33173 VDHY 34173

Mercury

Vapor

1001/2" VDMY 31105 VDMY 32105 VDMY 33105 VDMY 34105

3/4" VDMY 31103 VDMY 32103 VDMY 33103 VDMY 34103

2001/2" VDMY 31205 VDMY 32205 VDMY 33205 VDMY 34205

3/4" VDMY 31203 VDMY 32203 VDMY 33203 VDMY 34203

* For Pole type, see pole section (2L-51)

Ordering Information

V D N Y 3 1 0 7 5 ① ② ③ ④ ⑤

VDY Lighting Fixture① Mounting Type③ Lamp Wattage (W)④ Entry Size⑤

31 - Pendant 07 - 70 1 - 1"

Lamp Type② 32 - Ceiling 10 - 100 3 - 3/4"

NY - High Pressure Sodium 33 - 90° Bracket 15 - 150 5 - 1/2"

HY - Metal Halide 34 - 40° Bracket 17 - 175

MY - Mercury Vapour 20 - 200

▞ Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

<VDNY 32105> 0 160 50 132

5 132 55 132Lamp : NH100 (9000 lm)+

With Globe and Guard+

Reflector : +

White Coating Aluminum

Reflector

10 132 60 132

15 146 65 125

20 160 70 125

25 153 75 111

30 146 80 83.3

35 139 85 27.8

40 139 90 6.9

45 132

Coefficients of Utilization - Zonal Cavity

%Effective Ceiling

Cavity Reflectance( ccρ )80 70 50 30 10 0

%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance

0 .84 .84 .84 .82 .82 .82 .78 .78 .78 .75 .75 .75 .72 .72 .72 .70

1 .73 .70 .68 .72 .69 .66 .69 .66 .64 .66 .64 .62 .63 .62 .61 .59

2 .64 .59 .55 .63 .58 .54 .60 .56 .53 .58 .55 .52 .56 .53 .51 .49

3 .56 .50 .46 .55 .50 .45 .53 .48 .44 .51 .47 .44 .49 .46 .43 .41

4 .50 .43 .39 .49 .43 .38 .47 .42 .38 .45 .41 .37 .44 .40 .37 .35

5 .44 .38 .33 .44 .38 .33 .42 .37 .33 .41 .36 .32 .39 .35 .32 .31

6 .40 .34 .29 .39 .33 .29 .38 .33 .29 .37 .32 .28 .36 .32 .28 .27

7 .36 .30 .26 .36 .30 .26 .35 .29 .26 .34 .29 .25 .33 .28 .25 .24

8 .33 .27 .23 .33 .27 .23 .32 .27 .23 .31 .26 .23 .30 .26 .23 .21

9 .31 .25 .21 .30 .25 .21 .29 .24 .21 .29 .24 .21 .28 .24 .21 .19

10 .28 .23 .19 .28 .23 .19 .27 .23 .19 .27 .22 .19 .26 .22 .19 .18

Page 27: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Dimension

< VDY Ceiling Type > < VDY 40° Bracket Type >

< VDY Pendant Type > < VDY 90° Bracket Type >

Page 28: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

H.I.D Lighting Fixtures

VS Series

Wet Locations

NEMA 3, 3R

Application

< VS >

VS Series lighting fixtures are used ;

in manufacturing plants, refineries, chemical,

petrochemical and other industrial process

facilities, wastewater and sewage treatment plants,

offshore, dockside and other harbor installations

as well as other heavy industrial applications.

in industrial areas, both indoors and outdoors

where long life and low maintenance costs are

desired.

Features

The lighting fixture has simple construction.

Relamping is easily done by opening lower half of

the guard and unscrewing the globe.

H.I.D lighting fixture has external type ballast.

Standard Materials Technical Data

Body : Die casting aluminium

Globe : Heat resistant hard glass

External Hardware : Cast aluminium alloy

Electrical Rating

Rated Voltage AC110V/ 220V/ 240V ( See Below)※

Rated Wattage 100W/ 150W/ 175W/ 200W/ 250W/ 400W

Rated Frequency 50Hz/ 60Hz

Compliance Entry Size 1/2", 3/4", 1"

IP55NEMA 3, 3R

Certification

Also you can order various voltage : ※

120V/ 208V/ 277V/ 460V

Certified by KOSHA (Korea Occupational

Safety & Health Agency), KGS (Korea Gas

Safety Corporation), and the others.

Standard Finish Weight

Natural

If you want another color, contact us

please.

Catalog No. Weight

VSNL 7240 18.8 ㎏

Ordering Number Ordering Information

Lamp Watt Pendant Ceiling90°

Bracket

40°

Bracket

V S N L 7 1 1 5

① ② ③ ④ ⑤

High

Pressure

Sodium

100 VSNL7110 VSNL7210 VSNL7310 VSNL7410 VS Lighting Fixture①

150 VSNL7115 VSNL7215 VSNL7315 VSNL7415

200 VSNL7120 VSNL7220 VSNL7320 VSNL7420 Lamp Type②

250 VSNL7125 VSNL7225 VSNL7325 VSNL7425 NL - High Pressure Sodium

400 VSNL7140 VSNL7240 VSNL7340 VSNL7440 HL - Metal Halide

Metal

Halide

100 VSHL7110 VSHL7210 VSHL7310 VSHL7410 ML - Mercury Vapour

175 VSHL7117 VSHL7217 VSHL7317 VSHL7417

250 VSHL7125 VSHL7225 VSHL7325 VSHL7425 Model Type③ Lamp Wattage (W)⑤

400 VSHL7140 VSHL7240 VSHL7340 VSHL7440 7 - VS Type 10 - 100

Mercury

Vapor

100 VSML7110 VSML7210 VSML7310 VSML7410 15 - 150

200 VSML7120 VSML7220 VSML7320 VSML7420 Mounting Type④ 17 - 175

250 VSML7125 VSML7225 VSML7325 VSML7425 1 - Pendant 20 - 200

300 VSML7130 VSML7230 VSML7330 VSML7430 2 - Ceiling 25 - 250

400 VSML7140 VSML7240 VSML7340 VSML7440 3 - 90° Bracket 30 - 300

* For Pole type, see pole section (2L-51) 4 - 40° Bracket 40 - 400

If you need more information, contact us please. ⇨

Page 29: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

<VSHL 7217> 0 169.6 50 187.5

5 165.2 55 205.4Lamp : MH175 (14000 lm)+

With Globe and without Guard+ 10 169.6 60 147.3

15 209.8 65 84.8

20 223.2 70 44.6

25 205.4 75 26.8

30 205.4 80 13.4

35 192.0 85 4.5

40 200.9 90 4.5

45 209.8

Coefficients of Utilization - Zonal Cavity%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance

0 .90 .90 .90 .88 .88 .88 .84 .84 .84 .80 .80 .80 .77 .77 .77 .76

1 .81 .78 .76 .79 .77 .74 .76 .74 .72 .73 .71 .70 .70 .69 .68 .66

2 .73 .69 .65 .71 .68 .64 .69 .66 .63 .66 .64 .61 .64 .62 .60 .59

3 .66 .60 .56 .64 .60 .56 .62 .58 .55 .60 .57 .54 .59 .56 .53 .52

4 .59 .54 .49 .58 .53 .49 .57 .52 .48 .55 .51 .48 .53 .50 .47 .46

5 .54 .48 .44 .53 .48 .44 .52 .47 .43 .50 .46 .43 .49 .45 .42 .41

6 .49 .43 .39 .48 .43 .39 .47 .42 .39 .46 .42 .38 .45 .41 .38 .37

7 .45 .39 .35 .45 .39 .35 .43 .38 .35 .42 .38 .35 .41 .37 .34 .33

8 .42 .36 .32 .41 .36 .32 .40 .35 .32 .39 .35 .31 .38 .34 .31 .30

9 .38 .33 .29 .38 .33 .29 .37 .32 .29 .36 .32 .29 .36 .32 .29 .27

10 .36 .30 .27 .35 .30 .27 .35 .30 .27 .34 .30 .26 .33 .29 .26 .25

Angle cd/1000 lm Angle cd/1000 lm

<VSNL 7225> 0 302 50 158

5 288 55 155Lamp : NH250 (25000 lm)+

With Globe and without +

Guard

10 235 60 142

15 210 65 108

20 182 70 72.5

25 162 75 47.5

30 165 80 27.5

35 160 85 15.0

40 152 90 7.5

45 155

Coefficients of Utilization - Zonal Cavity%Effective Ceiling Cavity

Reflectance( cc)ρ80 70 50 30 10 0

%Wall

Reflectance(ρw)50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity Ratio

RCR20% Effective Floor Cavity Reflectance

0 .83 .83 .83 .81 .81 .81 .77 .77 .77 .74 .74 .74 .71 .71 .71 .70

1 .73 .70 .67 .71 .69 .66 .68 .66 .64 .66 .64 .62 .63 .62 .60 .59

2 .65 .60 .57 .64 .60 .56 .61 .58 .55 .59 .56 .54 .57 .55 .52 .51

3 .58 .53 .49 .57 .52 .48 .55 .51 .47 .53 .49 .47 .51 .48 .46 .44

4 .52 .46 .42 .51 .46 .42 .49 .45 .41 .48 .44 .41 .46 .43 .40 .39

5 .47 .41 .37 .46 .41 .37 .45 .40 .37 .44 .39 .36 .42 .39 .36 .34

6 .43 .37 .33 .42 .37 .33 .41 .36 .33 .40 .36 .32 .39 .35 .32 .31

7 .39 .34 .30 .39 .33 .30 .38 .33 .29 .37 .32 .29 .36 .32 .29 .28

8 .36 .31 .27 .36 .30 .27 .35 .30 .27 .34 .30 .26 .33 .29 .26 .25

9 .34 .28 .25 .33 .28 .25 .32 .28 .24 .32 .27 .24 .31 .27 .24 .23

10 .31 .26 .23 .31 .26 .23 .30 .26 .22 .30 .25 .22 .29 .25 .22 .21

Page 30: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Dimension

< VS Ceiling Type > < VS 40° Bracket Type >

< VS Pendant Type > < VS 90° Bracket Type >

Page 31: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

H.I.D Lighting Fixtures

SR Series

Wet Locations

NEMA 3, 3R, 4, 4X, 7

Type of Explosion-proof

< SR >

Non Sparking (Ex nR II T3)

Application

SR Series lighting fixtures are used ;

in heavy process industries having environments

where flammable or explosive vapors or gases, or

where combustible dusts are present.

in hazardous areas, both indoors and outdoors where

long life and low maintenance costs are desired.

in petroleum refineries, chemical, petrochemical and

other heavy process industry facilities.

where ignitable concentrations of flammable gases,

vapors or liquids can exist all of the time or some of

the time under normal operation conditions.

Features Certification Standard Materials

The globe frame is cast in one

piece with guard.

The globe is sealed into the

globe frame firmly with synthetic

rubber gaskets, and the globe

assembly is fitted to the body by

three socket head captive

screws.

All joint of lamp housing,

including the joint between the

top body and the terminal plate,

are sealed up with high quality

gaskets so as to restrict

breathing.

The body and ballast are

constructed separately so as to

protect the ballast from the heat

of the lamp.

Certified by KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas Safety

Corporation), and the others.

Enclosure : Aluminium sheet

Globe : Heat resistant hard glass

Globe Frame : Die casting

aluminium alloy

Mounting Box : Cast aluminium

alloy

External Hardware : Stainless

steelCompliance

NEMA 3 ,3R, 4, 4X, 7

IEC 60079-0, 15

IP55

Standard FinishOptions

MUNSELL No. 7.5BG 6/1.5

If you want another color,

contact us please.

With Choke or Lead Peak type

Ballast

Technical DataWeightElectrical Rating

Rated Voltage AC110V/ 220V/ 240V ( See Below)※ Enclosure Type Catalog No. Weight

Rated Wattage 100W/ 150W/ 175W/ 200W/ 250W/ 400W Small (Ceiling) SRHL 2105 10.3 Kg

Entry Size 1/2", 3/4", 1" Middle (Ceiling) SRHL 2255 19.6 Kg

If you need more information, contact us please. ⇨

Page 32: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number

Lamp WattHub

SizePendant Ceiling 90° Bracket 40° Bracket Certification

High

Pressure

Sodium

1001/2" SRNL1105 SRNL2105 SRNL3105 SRNL4105

Ex nR II T3

3/4" SRNL1103 SRNL2103 SRNL3103 SRNL4103

1501/2" SRNL1155 SRNL2155 SRNL3155 SRNL4155

3/4" SRNL1153 SRNL2153 SRNL3153 SRNL4153

2001/2" SRNL1205 SRNL2205 SRNL3205 SRNL4205

3/4" SRNL1203 SRNL2203 SRNL3203 SRNL4203

2501/2" SRNL1255 SRNL2255 SRNL3255 SRNL4255

3/4" SRNL1253 SRNL2253 SRNL3253 SRNL4253

4001/2" SRNL1405 SRNL2405 SRNL3405 SRNL4405

3/4" SRNL1403 SRNL2403 SRNL3403 SRNL4403

Metal

Halide

1001/2" SRHL1105 SRHL2105 SRHL3105 SRHL4105

3/4" SRHL1103 SRHL2103 SRHL3103 SRHL4103

1751/2" SRHL1175 SRHL2175 SRHL3175 SRHL4175

3/4" SRHL1173 SRHL2173 SRHL3173 SRHL4173

2501/2" SRHL1255 SRHL2255 SRHL3255 SRHL4255

3/4" SRHL1253 SRHL2253 SRHL3253 SRHL4253

4001/2" SRHL1405 SRHL2405 SRHL3405 SRHL4405

3/4" SRHL1403 SRHL2403 SRHL3403 SRHL4403

Mercury

Vapor

1001/2" SRML1105 SRML2105 SRML3105 SRML4105

3/4" SRML1103 SRML2103 SRML3103 SRML4103

2001/2" SRML1205 SRML2205 SRML3205 SRML4205

3/4" SRML1203 SRML2203 SRML3203 SRML4203

2501/2" SRML1255 SRML2255 SRML3255 SRML4255

3/4" SRML1253 SRML2253 SRML3253 SRML4253

4001/2" SRML1405 SRML2405 SRML3405 SRML4405

3/4" SRML1403 SRML2403 SRML3403 SRML4403

* For Pole type, see pole section (2L-51)

Ordering Information

S R N L 1 1 0 5 ① ② ③ ④ ⑤

SR Lighting Fixture① ③ Mounting Type Lamp Wattage (W)④ Entry Size⑤

1 - Pendant 10 - 100 1 - 1"

Lamp Type② 2 - Ceiling 15 - 150 3 - 3/4"

NL - High Pressure Sodium 3 - 90° Bracket 17 - 175 5 - 1/2"

HL - Metal Halide 4 - 40° Bracket 20 - 200

ML - Mercury Vapour 25 - 250

40 - 400

Page 33: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

<SRNL 2255> 0 170 50 130

5 118 55 102Lamp : NH250 (25000 lm)+

With Globe and Guard + 10 128 60 80.0

15 152 65 50.0

20 175 70 25.0

25 170 75 12.5

30 158 80 7.5

35 148 85 5.0

40 145 90 2.5

45 142

Multipliers Coefficients of Utilization - Zonal Cavity

(For use with

candlepower

curves only)

%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Lamp

Watts

Conversion

Factor

Room Cavity Ratio

RCR20% Effective Floor Cavity Reflectance

0 .59 .59 .59 .58 .58 .58 .55 .55 .55 .53 .53 .53 .51 .51 .51 .50

250 1 1 .53 .52 .50 .52 .51 .49 .50 .49 .48 .48 .47 .46 .46 .46 .45 .44

2 .48 .46 .43 .47 .45 .43 .46 .44 .42 .44 .42 .41 .43 .41 .40 .39

200 0.8 3 .44 .41 .38 .43 .40 .38 .42 .39 .37 .40 .38 .36 .39 .37 .36 .35

4 .40 .36 .34 .39 .36 .34 .38 .35 .33 .37 .35 .33 .36 .34 .32 .31

150 0.6 5 .37 .33 .30 .36 .33 .30 .35 .32 .30 .34 .32 .29 .33 .31 .29 .28

6 .34 .30 .27 .33 .30 .27 .32 .29 .27 .32 .29 .27 .31 .28 .27 .26

100 0.4 7 .31 .27 .25 .31 .27 .25 .30 .27 .25 .29 .26 .24 .29 .26 .24 .23

8 .29 .25 .23 .28 .25 .23 .28 .25 .22 .27 .24 .22 .27 .24 .22 .21

9 .27 .23 .21 .26 .23 .21 .26 .23 .21 .25 .23 .21 .25 .22 .21 .20

10 .25 .22 .19 .25 .21 .19 .24 .21 .19 .24 .21 .19 .23 .21 .19 .18

Angle cd/1000 lm Angle cd/1000 lm

<SRHL2255> 0 203 50 220

5 168 55 204Lamp : MH250 (20500 lm)+

With Globe and Guard + 10 156 60 137

15 143 65 57.9

20 152 70 27.4

25 174 75 12.2

30 213 80 6.1

35 238 85 3.0

40 229 90 3.0

45 229

Multipliers Coefficients of Utilization - Zonal Cavity

(For use with

candlepower

curves only)

%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall

Reflectance(ρw)50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Lamp

Watts

Conversion

FactorRoom Cavity Ratio

RCR20% Effective Floor Cavity Reflectance

0 .86 .86 .86 .84 .84 .84 .80 .80 .80 .77 .77 .77 .74 .74 .74 .72

250 1 1 .77 .75 .72 .76 .73 .71 .73 .71 .69 .70 .68 .67 .67 .66 .65 .64

2 .70 .66 .63 .69 .65 .62 .66 .63 .61 .64 .61 .59 .62 .60 .58 .57

175 0.68 3 .63 .58 .55 .62 .58 .54 .60 .56 .53 .58 .55 .52 .56 .54 .51 .50

4 .57 .52 .48 .56 .51 .48 .55 .50 .47 .53 .49 .46 .52 .48 .46 .45

5 .52 .46 .42 .51 .46 .42 .50 .45 .42 .48 .45 .41 .47 .44 .41 .40

6 .47 .42 .38 .47 .41 .38 .46 .41 .37 .44 .40 .37 .43 .40 .37 .35

7 .43 .38 .34 .43 .38 .34 .42 .37 .34 .41 .37 .33 .40 .36 .33 .32

8 .40 .34 .31 .39 .34 .31 .38 .34 .30 .38 .33 .30 .37 .33 .30 .29

9 .37 .31 .28 .36 .31 .28 .36 .31 .28 .35 .31 .27 .34 .30 .27 .26

10 .34 .29 .25 .34 .29 .25 .33 .28 .25 .32 .28 .25 .32 .28 .25 .24

Page 34: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Dimension

< SR 90° Bracket Type > < SR 40° Bracket Type >

< SR Ceiling Type > < SR Pendant Type >

LAMP WATTCeiling Type Pendant Type 90° Bracket 40° Bracket

A BØ A BØ A BØ A BØ C

Max. 100W 550 275 310 275 420 275 650 275 345

Max. 250W 640 340 400 340 510 340 710 340 400

Max. 400W 695 385 455 385 565 385 750 385 430

Page 35: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

V Series H.I.D Lighting Fixtures

VG, VN, VZ Series

Wet Locations

Marine Locations

NEMA 3,3R,4,4X,7

< VG > < VN > < VZ >

Type of Explosion-proof Fixture Wattage

Class I Division 2 Group A,B,C,D

Class II Division 1,2 Group E,F,G

Class III Division 1

Simultaneous Presence (VN Series)

Non Sparking (Ex nR II T4 IP66)

Dust Ignition-proof (Ex DP II 11)

Lamp V Series Wattage

Type VG VN VZ

HPS 50, 70, 100 150, 200, 250 250, 400

MH 100 175, 250 250, 400

MV 100 200, 250 250, 400

Application in hazardous locations requiring

elevated ambient capability.

in installations where moisture,

dirt, dust, vibration, corrosion

and rough usage are problems.

Four mounting arrangements to

suit any lighting layout pendant,

ceiling, wall bracket and stanchion.

Internal ballasts-separate ballasts

are not required. High power

factor (90%) ballasts reduce

power costs allow more fixtures

per circuit.

Cast aluminium alloy construction

and epoxy powder finish provide

excellent resistant to corrosion.

V Series HID lighting fixtures are

used ;

in heavy process industries

having environments where

flammable or explosive vapors or

gases, or where combustible

dusts are present.

in hazardous areas, both indoors

and outdoors where long life

and low maintenance costs are

desired.

in petroleum refineries, chemical,

petrochemical and other heavy

process industry facilities.

in paint spray booth suitability

provides efficient, economical

HID lighting for paint spray

areas.

where ignitable concentrations of

flammable gases, vapors or

liquids can exist all of the time

or some of the time under

normal operation conditions.

Features

Hinged ballast housing for ease

of installation and maintenance

Hubs with integral conduit stop

and bushing to help prevent

damage to field wiring during

installation.

Factory sealed, porcelain with

mogul or medium base socket.

Dome and 30°angle reflectors

made of FRP material won't rust,

corrode, dent, chip or peel.

If you need more data, contact us please. ⇨

Page 36: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

V Series H.I.D Lighting Fixtures

VG Series

Wet Locations

Marine Locations

NEMA 3,3R,4,4X,7

Type of Explosion-proof

Non Sparking (Ex nR II T4 IP66)

Class I Division 2 Group A,B,C,D

Features Standard Materials

Compact, lightweight design is ideal for medium and

low mounting heights.

Cast aluminium alloy construction and epoxy powder

finish provide excellent resistant to corrosion.

Hubs with integral conduit stop and bushing to help

prevent damage to field wiring during installation.

Restricted Breathing Construction : zone 2 only

Enclosure : Die casting aluminium

Globe : Heat resistant hard glass

Lamp socket : Porcelain with screw shell

Reflector : High grade aluminium sheet

Guard : Die casting aluminium

Compliance & Certification

< VG >

NEC - Class I Division 2 Group A,B,C,D

UL 844 - Lighting Fixtures for Use in Hazardous

(Classified) Locations

UL Listed File No. E 131747

IEC 60079-0, 15

NEMA 3, 3R, 4, 4X, 7

Certified by UL (Underwriters Laboratories Inc.),

KOSHA (Korea Occupational Safety & Health

Agency), KGS (Korea Gas Safety Corporation), and

the others.

Options

With Dome Reflector or 30° Angle Reflector

Instant Restrike (HPS only)

Fused to protect ballast and capacitors

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

Technical Data Weight

Electrical Rating Mounting Type Catalog No. Weight

Rated Voltage

AC110V/ 220V/ 240V Ceiling VGNL 22103 7.7 ㎏

(110V/ 120V/ 208V/ 220V/

240V/ 277V for UL Listed)

Rated Wattage 50W/ 70W/ 100W

Rated Frequency 50Hz/ 60Hz

Entry Size 1/2", 3/4", 1"

If you need more information, contact us please. ⇨

Page 37: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number

Lamp WattHub

SizePendant Ceiling Bracket Stanchion Certification

High

Pressure

Sodium

501" VGNL 12051 VGNL 22051 VGNL 32051 VGNL 92051

Ex nR II T4 IP66

Class I Division 2

Group A,B,C,D

3/4" VGNL 12053 VGNL 22053 VGNL 32053 VGNL 92053

701" VGNL 12071 VGNL 22071 VGNL 32071 VGNL 92071

3/4" VGNL 12073 VGNL 22073 VGNL 32073 VGNL 92073

1001" VGNL 12101 VGNL 22101 VGNL 32101 VGNL 92101

3/4" VGNL 12103 VGNL 22103 VGNL 32103 VGNL 92103

Metal

Halide100

1" VGHL 12101 VGHL 22101 VGHL 32101 VGHL 92101

Ex nR II T3 IP66

Class I Division 2

Group A,B,C,D

3/4" VGHL 12103 VGHL 22103 VGHL 32103 VGHL 92103

Mercury

Vapor100

1" VGML 12101 VGML 22101 VGML 32101 VGML 92101

3/4" VGML 12103 VGML 22103 VGML 32103 VGML 92103

Ordering Information Dimension

<Bracket Type>

<Stanchion Type>

<Ceiling Type>

<Pendant Type>

V G N L 1 2 0 5 1 - DR ① ② ③ ④ ⑤ ⑥ ⑦

VG Lighting Fixture① Lamp Wattage (W)⑤

05 - 50

Lamp Type② 07 - 70

NL - High Pressure Sodium 10 - 100

HL - Metal Halide

ML - Mercury Vapour

Mounting Type③ Entry Size⑥

1 - Pendant 1 - 1"

2 - Ceiling 3 - 3/4"

3 - Bracket 5 - 1/2"

9 - Stanchion

Input Voltage (V)④

1 - 120 Options⑦

2 - 220 DR - Dome Type Reflector

3 - 110 AR - Angle Type Reflector

4 - 208

5 - 277 IR - Instant Restrike

6 - 240 FU - Fused Type

7 - 230

Temperature Performance Data

Lamp Ambient Class I Non-Sparking

Type Watt. Temp ( )℃ Div. 2 "nR"

High

Pressure

Sodium

5040 260 (T2B) T4

55 - T4

7040 260 (T2B) T4

55 - T4

10040 260 (T2B) T4

55 - T4

Metal

Halide100

40 - T3

55 - T3

Mercury

Vapor100

40 280 (T2A) T4

55 - T4

Page 38: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

<VGNL 12101-DR> 0 78.7 50 262.4

5 77.8 55 239.1Lamp : NH100 (9000 lm)+

With Guard+

Reflector : +

Aluminium Dome type

Reflector

10 79.7 60 199.7

15 88.2 65 169.7

20 111.5 70 158.5

25 135.9 75 113.4

30 157.5 80 65.6

35 189.4 85 23.5

40 218.4 90 13.1

45 248.4

Multipliers Coefficients of Utilization - Zonal Cavity(For use with

candlepower

curves only)

%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Lamp

Watts

Conversion

Factor

Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance

0 .91 .91 .91 .89 .89 .89 .85 .85 .85 .81 .81 .81 .78 .78 .78 .77

1 .78 .75 .72 .77 .73 .70 .73 .71 .68 .70 .68 .66 .68 .66 .64 .62

100 1 2 .67 .61 .57 .66 .60 .56 .63 .58 .55 .60 .57 .53 .58 .55 .52 .50

3 .58 .51 .46 .57 .50 .45 .54 .49 .44 .52 .48 .44 .50 .46 .43 .41

70 0.5 4 .51 .43 .38 .50 .43 .38 .48 .42 .37 .46 .41 .37 .44 .40 .36 .34

5 .45 .38 .32 .44 .37 .32 .42 .36 .32 .41 .35 .31 .39 .35 .31 .29

50 0.25 6 .40 .33 .28 .39 .33 .28 .38 .32 .27 .37 .31 .27 .35 .31 .27 .25

7 .36 .29 .24 .36 .29 .24 .34 .28 .24 .33 .28 .24 .32 .27 .24 .22

8 .33 .26 .22 .32 .26 .21 .31 .26 .21 .30 .25 .21 .30 .25 .21 .19

9 .30 .24 .19 .30 .24 .19 .29 .23 .19 .28 .23 .19 .27 .22 .19 .17

10 .28 .22 .17 .28 .22 .17 .27 .21 .17 .26 .21 .17 .25 .21 .17 .16

Angle cd/1000 lm Angle cd/1000 lm

<VGHL 12101-DR> 0 90.9 50 199.9

5 90.9 55 164.8Lamp : MH100 (6500 lm)+

With Guard+

Reflector : +

Aluminium Dome type

Reflector

10 94.8 60 144.0

15 114.2 65 132.4

20 133.7 70 48.1

25 177.8 75 27.3

30 218.0 80 16.9

35 266.1 85 11.7

40 266.1 90 9.0

45 245.3

Coefficients of Utilization - Zonal Cavity%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance

0 .95 .95 .95 .93 .93 .93 .89 .89 .89 .85 .85 .85 .82 .82 .82 .80

1 .86 .83 .80 .84 .81 .79 .81 .78 .77 .77 .76 .74 .75 .73 .72 .70

2 .77 .72 .68 .75 .71 .67 .72 .69 .66 .70 .67 .64 .68 .65 .63 .61

3 .69 .63 .59 .67 .62 .58 .62 .61 .57 .63 .59 .56 .61 .58 .55 .54

4 .62 .56 .51 .61 .55 .50 .59 .54 .50 .57 .53 .49 .55 .52 .49 .47

5 .56 .49 .44 .55 .49 .44 .53 .48 .44 .52 .47 .43 .50 .46 .43 .41

6 .50 .44 .39 .50 .44 .39 .48 .43 .39 .47 .42 .38 .46 .42 .38 .37

7 .46 .40 .35 .45 .39 .35 .44 .39 .35 .43 .38 .34 .42 .38 .34 .33

8 .42 .36 .31 .42 .35 .31 .41 .35 .31 .40 .35 .31 .39 .34 .31 .29

9 .39 .32 .28 .38 .32 .28 .37 .32 .28 .36 .32 .28 .36 .31 .28 .26

10 .36 .30 .26 .35 .30 .26 .35 .29 .26 .34 .29 .25 .33 .29 .25 .24

Page 39: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

V Series H.I.D Lighting Fixtures

VN Series

Wet Locations

Marine Locations

NEMA 3,3R,4,4X,7,9

< VN >

Type of Explosion-proof

Non Sparking (Ex nR II T3 IP66)

Dust Ignition-proof (Ex DP II 11)

Class I Division 2 Group A,B,C,D

Class II Division 1,2 Group E,F,G

Class III Division 1

Features

Compact, lightweight design is ideal for medium

and low mounting heights.

Wide range of light sources to meet specific

lighting needs - High Pressure Sodium (HPS):

150, 200 and 250W, Mercury Vapour (MV): 200

and 250W, Metal Halide (MH): 175 and 250W.

Restricted Breathing Construction : Zone 2 only

Standard Materials

Enclosure : Die casting aluminium

Globe : Heat resistant hard glass

Lamp socket :

Porcelain with screw shell

Reflector : Aluminium sheet /

Fiberglass-Reinforced Polyester

Guard : Stainless steel

Certification Compliance Options

UL Listed File No. E 131747

Certified by UL (Underwriters

Laboratories Inc.), KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas Safety

Corporation), and the others.

NEC - Class I Division 2 Group

A,B,C,D, / Class II Division 1,2

Group E,F,G / Class III Division 1

UL 844 - Lighting Fixtures for Use

in Hazardous (Classified) Locations

IEC 60079-0, 15

NEMA 3, 3R, 4, 4X, 7, 9

With Dome Reflector or 30°

Angle Reflector

Instant Restrike (HPS only)

Fused to protect ballast and

capacitors

Quartz Auxiliary Lighting come

to full brightness immediately

(Non-hazardous location only)Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color, contact

us please.

Technical Data WeightElectrical Rating

Mounting Type Catalog No. Weight

Rated Voltage

AC110V/ 220V/ 240V

(110V/ 120V/ 208V/ 220V/

240V/ 277V for UL Listed)Pendant VNNL 12153 12.6 ㎏

Ceiling VNNL 22153 12.8 ㎏Rated Wattage 150W/ 175W/ 200W/ 250W

Rated Frequency 50Hz/ 60Hz

Entry Size 1/2", 3/4", 1"

If you need more information, contact us please. ⇨

Page 40: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number

Lamp WattHub

SizePendant Ceiling Bracket Stanchion Certification

High

Pressure

Sodium

1501" VNNL 12151 VNNL 22151 VNNL 32151 VNNL 92151

Ex nR II T3 IP66

Ex DP II 11

3/4" VNNL 12153 VNNL 22153 VNNL 32153 VNNL 92153

2001" VNNL 12201 VNNL 22201 VNNL 32201 VNNL 92201

3/4" VNNL 12203 VNNL 22203 VNNL 32203 VNNL 92203

2501" VNNL 12251 VNNL 22251 VNNL 32251 VNNL 92251

3/4" VNNL 12253 VNNL 22253 VNNL 32253 VNNL 92253

Metal

Halide

1751" VNHL 12171 VNHL 22171 VNHL 32171 VNHL 92171

Ex nR II T3 IP66

Ex DP II 12 IP66

3/4" VNHL 12173 VNHL 22173 VNHL 32173 VNHL 92173

2501" VNHL 12251 VNHL 22251 VNHL 32251 VNHL 92251

3/4" VNHL 12253 VNHL 22253 VNHL 32253 VNHL 92253

Mercury

Vapor

2001" VNML 12201 VNML 22201 VNML 32201 VNML 92201

Ex nR II T4 IP66

Ex DP II 11

3/4" VNML 12203 VNML 22203 VNML 32203 VNML 92203

2501" VNML 12251 VNML 22251 VNML 32251 VNML 92251

3/4" VNML 12253 VNML 22253 VNML 32253 VNML 92253

Ordering Information

V N N L 1 2 1 5 1 - DR① ② ③ ④ ⑤ ⑥ ⑦

VN Lighting Fixture① Lamp Type② Mounting Type③ Input Voltage (V)④

NL - High Pressure Sodium 1 - Pendant 1 - 120

HL - Metal Halide 2 - Ceiling 2 - 220

ML - Mercury Vapour 3 - Bracket 3 - 110

9 - Stanchion 4 - 208

Lamp Wattage (W)⑤ : Entry Size⑥ Options⑦ 5 - 277

15 - 150 1 - 1" DR - Dome Type Reflector 6 - 240

17 - 175 3 - 3/4" AR - Angle Type Reflector 7 - 230

20 - 200 5 - 1/2" IR - Instant Restrike Type

25 - 250 FU - Fused Type

QAL - Quartz Auxiliary Lighting Type

Temperature Performance Data

Lamp Ambient Class I Class II Non-Sparking Dust Ignition

Type Watt. Temp ( )℃ Div. 2 Div. 1 "nR" Proof "DP"

High

Pressure

Sodium

15040 260 (T2B) 160 (T2C) T3 11

55 - - T3 -

20040 260 (T2B) 160 (T2C) T3 11

55 - - T3 -

25040 260 (T2B) 160 (T2C) T3 11

55 - - T3 -

Metal

Halide

17540 - 160 (T2C) T3 11

55 - T3 -

25040 300 (T2) 160 (T2C) T3 11

55 - - T3 -

Mercury

Vapor

20040 325 (T1) 165 (T2B) T4 11

55 - - - -

25040 325 (T1) 165 (T2B) T4 11

55 - - - -

Page 41: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

<VNNL 12251-DR> 0 91.0 50 136

5 91.0 55 140Lamp : NH250 (25000 lm)+

With Guard+

Reflector : +

FRP Dome Reflector

10 91.0 60 140

15 107 65 140

20 123 70 143

25 130 75 136

30 130 80 110

35 127 85 68.3

40 130 90 22.8

45 133

Multipliers Coefficients of Utilization - Zonal Cavity

(For use with

candlepower

curves only)

%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Lamp

Watts

Conversion

Factor

Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance

0 .91 .91 .91 .89 .89 .89 .85 .85 .85 .81 .81 .81 .78 .78 .78 .77

1 .78 .75 .72 .77 .73 .70 .73 .71 .68 .70 .68 .66 .68 .66 .64 .62

250 1 2 .67 .61 .57 .66 .60 .56 .63 .58 .55 .60 .57 .53 .58 .55 .52 .50

3 .58 .51 .46 .57 .50 .45 .54 .49 .44 .52 .48 .44 .50 .46 .43 .41

200 0.8 4 .51 .43 .38 .50 .43 .38 .48 .42 .37 .46 .41 .37 .44 .40 .36 .34

5 .45 .38 .32 .44 .37 .32 .42 .36 .32 .41 .35 .31 .39 .35 .31 .29

150 0.56 6 .40 .33 .28 .39 .33 .28 .38 .32 .27 .37 .31 .27 .35 .31 .27 .25

7 .36 .29 .24 .36 .29 .24 .34 .28 .24 .33 .28 .24 .32 .27 .24 .22

8 .33 .26 .22 .32 .26 .21 .31 .26 .21 .30 .25 .21 .30 .25 .21 .19

9 .30 .24 .19 .30 .24 .19 .29 .23 .19 .28 .23 .19 .27 .22 .19 .17

10 .28 .22 .17 .28 .22 .17 .27 .21 .17 .26 .21 .17 .25 .21 .17 .16

Angle cd/1000 lm Angle cd/1000 lm

<VNHL 12251-DR> 0 102 50 130

5 102 55 140Lamp : MH250 (20500 lm)+

With Guard+

Reflector : +

FRP Dome Reflector

10 98.2 60 144

15 119 65 144

20 133 70 144

25 133 75 144

30 137 80 130

35 133 85 59.6

40 140 90 10.5

45 126

Multipliers Coefficients of Utilization - Zonal Cavity

(For use with

candlepower

curves only)

%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Lamp

Watts

Conversion

Factor

Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance

0 .92 .92 .92 .90 .90 .90 .86 .86 .86 .82 .82 .82 .79 .79 .79 .77

1 .79 .76 .73 .78 .74 .71 .74 .72 .69 .71 .69 .67 .68 .67 .65 .63

250 1 2 .68 .62 .58 .67 .61 .57 .64 .59 .55 .61 .57 .54 .59 .56 .53 .51

3 .59 .52 .47 .58 .51 .46 .55 .50 .45 .53 .48 .44 .51 .47 .44 .42

175 0.68 4 .52 .44 .39 .50 .44 .38 .48 .43 .38 .47 .41 .37 .45 .40 .37 .35

5 .46 .38 .33 .45 .38 .33 .43 .37 .32 .41 .36 .32 .40 .35 .31 .30

6 .41 .34 .28 .40 .33 .28 .39 .32 .28 .37 .32 .28 .36 .31 .27 .26

7 .37 .30 .25 .36 .29 .25 .35 .29 .24 .34 .28 .24 .33 .28 .24 .22

8 .34 .27 .22 .33 .27 .22 .32 .26 .22 .31 .26 .22 .30 .25 .22 .20

9 .31 .24 .20 .30 .24 .20 .30 .24 .20 .29 .23 .20 .28 .23 .19 .18

10 .29 .22 .18 .28 .22 .18 .27 .22 .18 .27 .21 .18 .26 .21 .18 .16

Page 42: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Dimension

< VN Bracket Type > < VN Stanchion Type >

< VN Ceiling Type > < VN Pendant Type >

Page 43: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

V Series H.I.D Lighting Fixtures

VZ Series

Wet Locations

Marine Locations

NEMA 3,3R,4,4X,7,9

Type of Explosion-proof

Non Sparking (Ex nR II T2 IP66)

Class I Division 2 Group A,B,C,D

Class II Division 1,2 Group E,F,G

Class III Division 1

Features Standard Materials

Low ambient capability to -40℃

Wide range of light sources to

meet specific lighting needs - High

Pressure Sodium (HPS): 250 and

400W, Mercury Vapour (MV): 250

and 400W, Metal Halide (MH): 250

and 400W

Restricted Breathing Construction :

Zone 2 only

< VZ >

Enclosure : Die casting aluminium

Globe : Heat resistant hard glass

Lamp socket :

Porcelain with screw shell

Reflector :

Aluminium sheet /

Fiberglass-Reinforced Polyester

Guard : Stainless steel

Certification

UL Listed File No. E 131747

Certified by UL (Underwriters

Laboratories Inc.), KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas Safety

Corporation), and the others.

Options

With Dome Reflector or 30° Angle

Reflector

Fused to protect ballast and

capacitors

Quartz Auxiliary Lighting come to

full brightness immediately

(Non-hazardous location only)

Compliance NEC - Class I Division 2 Group

A,B,C,D, / Class II Division 1,2

Group E,F,G / Class III Division 1

UL 844 - Lighting Fixtures for Use

in Hazardous (Classified) Locations

IEC 60079-0, 15

NEMA 3, 3R, 4, 4X, 7, 9

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color, contact

us please.

Technical Data Weight

Electrical Rating Mounting Type Catalog No. Weight

Rated VoltageAC110V/ 220V/ 240V

( See Below)※Bracket VZNL 32253 18.8 ㎏

Rated Wattage 250W/ 400W

Rated Frequency 50Hz/ 60Hz

Entry Size 1/2", 3/4", 1"

Also you can order various voltage : ※ 120V/ 208V/ 277V/ 460V

If you need more information, contact us please. ⇨

Page 44: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number

Lamp WattHub

SizePendant Ceiling Bracket Stanchion Certification

High

Pressure

Sodium

2501" VZNL 12251 VZNL 22251 VZNL 32251 VZNL 92251

Ex nR II T33/4" VZNL 12253 VZNL 22253 VZNL 32253 VZNL 92253

4001" VZNL 12401 VZNL 22401 VZNL 32401 VZNL 92401

Ex nR II T23/4" VZNL 12403 VZNL 22403 VZNL 32403 VZNL 92403

Metal

Halide

2501" VZHL 12251 VZHL 22251 VZHL 32251 VZHL 92251

Ex nR II T33/4" VZHL 12253 VZHL 22253 VZHL 32253 VZHL 92253

4001" VZHL 12401 VZHL 22401 VZHL 32401 VZHL 92401

Ex nR II T23/4" VZHL 12403 VZHL 22403 VZHL 32403 VZHL 92403

Mercury

Vapor

2501" VZML 12251 VZML 22251 VZML 32251 VZML 92251

Ex nR II T33/4" VZML 12253 VZML 22253 VZML 32253 VZML 92253

4001" VZML 12401 VZML 22401 VZML 32401 VZML 92401

Ex nR II T23/4" VZML 12403 VZML 22403 VZML 32403 VZML 92403

Ordering Information

V Z N L 1 2 2 5 1 - DR ① ② ③ ④ ⑤ ⑥ ⑦

VZ Lighting Fixture① Lamp Type② Mounting Type③ Input Voltage (V)④

NL - High Pressure Sodium 1 - Pendant 1 - 120

HL - Metal Halide 2 - Ceiling 2 - 220

ML - Mercury Vapour 3 - Bracket 3 - 110

9 - Stanchion 4 - 208

5 - 277

Lamp Wattage (W)⑤ Entry Size⑥ Options⑦ 6 - 240

25 - 250 1 - 1" DR - Dome Type Reflector 7 - 230

40 - 400 3 - 3/4" AR - Angle Type Reflector

5 - 1/2" FU - Fused Type

QAL - Quartz Auxiliary Lighting Type

Temperature Performance Data

Lamp Ambient Non Sparking

Type Watt. Temp ( )℃ "nR"

High

Pressure

Sodium

25040 T3

55 T3

40040 T2

55 T2

Metal

Halide

25040 T3

55 T3

40040 T2

55 T2

Mercury

Vapor

25040 T3

55 T3

40040 T2

55 T2

Page 45: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

0 13.9 50 86.3<VZNL 22401-DR>

5 14.7 55 93.6Lamp : NH400 (46000 lm)+

With Globe and without Guard+

Reflector : +

FRP Dome Reflector

10 15.7 60 92.5

15 27.5 65 97.2

20 36.7 70 100

25 40.4 75 104

30 45.0 80 104

35 50.6 85 106

40 70.1 90 106

45 77.9

Coefficients of Utilization - Zonal Cavity

%Effective Ceiling Cavity Reflectance( cc)ρ

80 70 50 30 10 0

%WallReflectance(ρw)

50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity RatioRCR

20% Effective Floor Cavity Reflectance

0 .63 .63 .63 .61 .61 .61 .58 .58 .58 .56 .56 .56 .54 .54 .54 .53

1 .52 .49 .47 .51 .48 .46 .49 .46 .44 .46 .45 .43 .44 .43 .42 .40

2 .43 .38 .34 .42 .38 .34 .40 .36 .33 .38 .35 .32 .36 .34 .31 .30

3 .36 .31 .26 .35 .30 .26 .33 .29 .25 .32 .28 .25 .30 .27 .24 .23

4 .31 .25 .21 .30 .25 .21 .29 .24 .20 .27 .23 .20 .26 .22 .20 .18

5 .27 .21 .17 .26 .21 .17 .25 .20 .17 .24 .20 .16 .23 .19 .16 .15

6 .24 .18 .14 .23 .18 .14 .22 .17 .14 .21 .17 .14 .20 .16 .13 .12

7 .21 .16 .12 .21 .15 .12 .20 .15 .12 .19 .15 .12 .18 .14 .11 .10

8 .19 .14 .10 .18 .14 .10 .18 .13 .10 .17 .13 .10 .16 .13 .10 .09

9 .17 .12 .09 .17 .12 .09 .16 .12 .09 .16 .12 .09 .15 .11 .09 .08

10 .16 .11 .08 .15 .11 .08 .15 .11 .08 .14 .10 .08 .14 .10 .08 .07

Angle cd/1000 lm Angle cd/1000 lm

0 19.3 50 115<VZHL 22401-DR>

5 20.7 55 111Lamp : MH400 (34000 lm)+

With Globe and without Guard+

Reflector : +

FRP Dome Reflector

10 22.1 60 113

15 30.2 65 119

20 43.2 70 124

25 54.4 75 128

30 53.9 80 131

35 68.4 85 134

40 67.8 90 139

45 105

Coefficients of Utilization - Zonal Cavity

%Effective Ceiling Cavity Reflectance( cc)ρ

80 70 50 30 10 0

%WallReflectance(ρw)

50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity RatioRCR

20% Effective Floor Cavity Reflectance

0 .79 .79 .79 .77 .77 .77 .73 .73 .73 .70 .70 .70 .67 .67 .67 .66

1 .65 .62 .58 .64 .61 .58 .61 .58 .56 .58 .56 .54 .56 .54 .52 .51

2 .54 .48 .43 .53 .47 .43 .50 .46 .42 .48 .44 .41 .46 .42 .40 .38

3 .45 .38 .33 .44 .38 .33 .42 .37 .32 .40 .35 .31 .38 .34 .31 .29

4 .39 .32 .26 .38 .31 .26 .36 .30 .26 .34 .29 .25 .33 .28 .25 .23

5 .34 .27 .21 .33 .26 .21 .31 .25 .21 .30 .25 .21 .29 .24 .20 .19

6 .30 .23 .18 .29 .23 .18 .28 .22 .18 .27 .21 .17 .25 .21 .17 .16

7 .27 .20 .15 .26 .20 .15 .25 .19 .15 .24 .19 .15 .23 .18 .15 .13

8 .24 .17 .13 .23 .17 .13 .22 .17 .13 .22 .16 .13 .21 .16 .13 .11

9 .22 .16 .11 .21 .15 .11 .20 .15 .11 .20 .15 .11 .19 .14 .11 .10

10 .20 .14 .10 .19 .14 .10 .19 .14 .10 .18 .13 .10 .17 .13 .10 .09

Page 46: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Dimension

< VZ Bracket Type > < VZ Ceiling Type >

< VZ Stanchion Type > < VZ Pendant Type >

Page 47: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

V Series H.I.D Lighting Fixtures

Auxiliary Lighting

< Auxiliary Lighting >

About Auxiliary Lighting Features V Series Auxiliary Lighting

Momentary voltage outages or dips

can temporarily extinguish HID

lamps which may require up to ten

minutes to restrike. To provide

illumination during this period,

10~20% of the fixtures should be

specified with auxiliary lighting.

Hinged ballast housing for ease

of installation and maintenance

Hubs with integral conduit stop

and bushing to help prevent

damage to field wiring during

installation.

Factory sealed, porcelain with

mogul or medium base socket.

Four mounting arrangements to

suit any lighting layout pendant,

ceiling, wall bracket and

stanchion.

Internal ballasts-separate ballasts

are not required. High power

factor (90%) ballasts reduce

power costs allow more fixtures

per circuit.

Cast aluminium alloy

construction and epoxy powder

finish provide excellent resistant

to corrosion.

Quartz auxiliary is available for

all V Series fixtures (except

those with plastic refractors) by

adding the suffix QAL to the

fixture catalog number.

(Example :

VN NL 1 2 15 1- QAL)

Series VG fixtures with this

option use 100 or 150 watt

quartz lamps. Series VN wattage

fixtures can use up to 250 watt

quartz lamps. Quartz lamps are

not supplied with the fixture

Due to the quartz envelope

surface temperature (exceeding

6000°C), fixtures with this option

are not suitable for Wet

hazardous locations. Contact the

Factory for specific fixture

suitabilities.

Instant Restart

Available for 70-150 Watt VG Series

High Pressure Sodium Fixtures by

adding Suffix "IR" to catalog

number (Ex: VN NL 1 2 15 1 - IR).

Additional instant restart interior

circuitry may decrease High

Pressure Sodium lamp life. Feature

will not affect fixture suitability in

hazardous location applications

Incandescent Auxiliary

With a surface lamp temperature

lower than quartz, incandescent

auxiliary lamps are available for

Series V fixtures.

Page 48: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

H.I.D Lighting Fixtures

EVN Series

Wet Locations

NEMA 3,3R,4,4X,7,9

Type of Explosion-proof Technical Data

Flameproof-Non Sparking (Ex dnR IIC T4)

Non Sparking (Ex nR II T4 IP66)

Dust Ignition-proof (Ex DP II 11 IP66)

Electrical Ratings

Rated Voltage AC110V/ 220V/ 240V ( See Below)※

Rated Wattage 50W/ 70W/ 100W/ 150W/

175W/ 200W/ 250W

Rated Frequency 50Hz/ 60HzWeightEntry Sizes 1/2", 3/4", 1"

Mounting Type Catalog No. WeightAlso you can order various voltage : ※

120V/ 208V/ 277V/ 460VPendant EVNNL 1255 11.5 Kg

< EVN >

Standard Finish

Dark Gray

If you want another color, contact us

please.

Certification

Certified by KOSHA (Korea

Occupational Safety & Health Agency),

KGS (Korea Gas Safety Corporation),

and the others.

Compliance

IEC 60079-0, 1, 15

NEMA 3, 3R, 4, 4X, 7, 9

Options

With Dome Reflector or 30°

Angle Reflector with SMC or High

Grade Aluminium

With Choke or Lead Peak type

Ballast

For various voltage from 110V to

240V

For 50Hz/ 60Hz

Application Features

EVN Series lighting fixtures are used ;

in manufacturing plants, refineries,

chemical, petrochemical and other

industrial process facilities, wastewater

and sewage treatment plants, offshore,

dockside and other harbor installations as

well as other heavy industrial applications.

wherever the damaging effects of water,

wind, snow, sleet, hot sun or any

combination of these elements are found.

in withstands the harshest of corrosive

environments.

to provide low wattage spot and

floodlighting.

where an explosive atmosphere consisting

of a mixture with air of flammable

substances in the form of gas, vapour or

mist is not likely to occur in normal

operation but, if it does occur, will persist

for a short period only.

where combustible dust, moisture, dirt are

present and vibration, corrosion, rough

usage are problems.

Enclosure in glass fiber

reinforced polyester resin,

provide excellent resistant to

corrosion so have a long life.

Enclosure contain ultraviolet

interception ingredient to

resist transformation.

Easy installation and

maintenance.

Pendant mounting module

equipped with integral hub

set screws for vibration

resistance.

Guard, hub inserts, stanchion

elbow and hardware made of

stainless steel for maximum

resistance to corrosion.

Grounding wire for safety.

Hinged assembly allows the

fixture to hang free during

installation to permit the use

of both hands when wiring.

Standard Materials

Housing, mounting modules,

component pallets : Fiberglass

reinforced polyester resin

Globe : Heat resistant hard glass

Gasket : Silicone rubber

Reflector : Fiberglass Reinforced

Polyester

External Hardware : Stainless

steel, Brass

If you need more information, contact us please. ⇨

Page 49: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number

Lamp Watt Hub Size Pendant Ceiling Bracket Stanchion Certification

High

Pressure

Sodium

501/2" EVNNL 1055 EVNNL 2055 EVNNL 3055 EVNNL 9055

Ex dnR IIC T4 IP66

Ex nR II T4 IP66

Ex DP II 11 IP66

3/4" EVNNL 1053 EVNNL 2053 EVNNL 3053 EVNNL 9053

701/2" EVNNL 1075 EVNNL 2075 EVNNL 3075 EVNNL 9075

3/4" EVNNL 1073 EVNNL 2073 EVNNL 3073 EVNNL 9073

1001/2" EVNNL 1105 EVNNL 2105 EVNNL 3105 EVNNL 9105

3/4" EVNNL 1103 EVNNL 2103 EVNNL 3103 EVNNL 9103

1501/2" EVNNL 1155 EVNNL 2155 EVNNL 3155 EVNNL 9155

3/4" EVNNL 1153 EVNNL 2153 EVNNL 3153 EVNNL 9153

2001/2" EVNNL 1205 EVNNL 2205 EVNNL 3205 EVNNL 9205

3/4" EVNNL 1203 EVNNL 2203 EVNNL 3203 EVNNL 9203

2501/2" EVNNL 1255 EVNNL 2255 EVNNL 3255 EVNNL 9255

3/4" EVNNL 1253 EVNNL 2253 EVNNL 3253 EVNNL 9253

Metal

Halide

1001/2" EVNHL 1105 EVNHL 2105 EVNHL 3105 EVNHL 9105

Ex dnR IIC T4 IP66

Ex nR II T3 IP66

Ex DP II 11 IP66

3/4" EVNHL 1103 EVNHL 2103 EVNHL 3103 EVNHL 9103

1751/2" EVNHL 1175 EVNHL 2175 EVNHL 3175 EVNHL 9175

3/4" EVNHL 1173 EVNHL 2173 EVNHL 3173 EVNHL 9173

2501/2" EVNHL 1255 EVNHL 2255 EVNHL 3255 EVNHL 9255 Ex dnR IIC T3 IP66

Ex nR II T3 IP663/4" EVNHL 1253 EVNHL 2253 EVNHL 3253 EVNHL 9253

Ordering Information Dimension

E VN N L 1 0 5 5 - DR ① ② ③ ④ ⑤ ⑥

EVN Lighting Fixture① Lamp Type②

NL - High Pressure Sodium

Mounting Type③ HL - Metal Halide

1 - Pendant ML - Mercury Vapour

2 - Ceiling

3 - Bracket Lamp Wattage (W)④

9 - Stanchion 05 - 50

07 - 70

Entry Size⑤ 10 - 100

1 - 1" 15 - 150

3 - 3/4" 17 - 175

5 - 1/2" 20 - 200

25 - 250

Options⑥

DR - Dome Reflector

AR - Angle Reflector

C※ an order Aluminium Reflector instead of FRP Reflector

< Pendant Type > < Ceiling Type >

Page 50: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

<EVNNL 2255-DR> 0 81.0 50 135

5 81.0 55 138Lamp : NH250 (25000 lm)+

With Globe and without Guard+

Reflector : FRP Dome Reflector+

10 81.0 60 145

15 87.8 65 148

20 97.9 70 148

25 111 75 148

30 115 80 125

35 115 85 81.0

40 122 90 33.8

45 128

Multipliers Coefficients of Utilization - Zonal Cavity

(For use with candlepower curves only)

%Effective Ceiling Cavity Reflectance( cc)ρ

80 70 50 30 10 0

%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0LampWatts

ConversionFactor

Room Cavity Ratio/RCR 20% Effective Floor Cavity Reflectance

0 .92 .92 .92 .90 .90 .90 .86 .86 .86 .82 .82 .82 .79 .79 .79 .77

1 .79 .75 .72 .77 .73 .70 .74 .71 .68 .70 .68 .66 .68 .66 .64 .62

250 1 2 .67 .61 .56 .65 .60 .55 .62 .58 .54 .60 .56 .52 .57 .54 .51 .49

3 .57 .50 .44 .56 .49 .44 .54 .48 .43 .51 .46 .42 .49 .45 .42 .40

200 0.8 4 .50 .42 .36 .49 .42 .36 .47 .40 .36 .45 .39 .35 .43 .38 .34 .33

5 .44 .36 .30 .43 .36 .30 .41 .35 .30 .40 .34 .30 .38 .33 .29 .27

150 0.56 6 .39 .31 .26 .38 .31 .26 .37 .30 .26 .35 .30 .25 .34 .29 .25 .23

7 .35 .28 .23 .34 .27 .22 .33 .27 .22 .32 .26 .22 .31 .26 .22 .20

8 .32 .25 .20 .31 .25 .20 .30 .24 .20 .29 .24 .20 .28 .23 .19 .18

9 .29 .22 .18 .29 .22 .18 .28 .22 .18 .27 .21 .17 .26 .21 .17 .16

10 .27 .20 .16 .26 .20 .16 .26 .20 .16 .25 .19 .16 .24 .19 .16 .14

Angle cd/1000 lm Angle cd/1000 lm

<EVNHL 2175-DR> 0 91.6 50 149

5 91.6 55 143Lamp : MH175 (14000 lm)+

With Globe and without Guard+

Reflector : FRP Dome Reflector+

10 97.4 60 143

15 97.4 65 143

20 115 70 143

25 126 75 137

30 132 80 132

35 137 85 91.6

40 137 90 17.2

45 143

Multipliers Coefficients of Utilization - Zonal Cavity

(For use with candlepower curves only)

%Effective Ceiling Cavity Reflectance( cc)ρ

80 70 50 30 10 0

%WallReflectance(ρw)

50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0Lamp

Watts

Conversion

FactorRoom Cavity Ratio RCR 20% Effective Floor Cavity Reflectance

250 1.47 0 .96 .96 .96 .94 .94 .94 .90 .90 .90 .86 .86 .86 .82 .82 .82 .81

1 .82 .78 .75 .80 .77 .74 .77 .74 .71 .74 .71 .69 .71 .69 .67 .65

175 1 2 .70 .64 .59 .69 .63 .58 .66 .61 .57 .63 .59 .55 .60 .57 .54 .52

3 .60 .53 .47 .59 .52 .47 .57 .51 .46 .54 .49 .45 .52 .48 .44 .42

4 .53 .45 .39 .52 .44 .39 .50 .43 .38 .48 .42 .38 .46 .41 .37 .35

5 .47 .39 .33 .46 .38 .33 .44 .37 .32 .42 .36 .32 .41 .36 .32 .30

6 .42 .34 .28 .41 .34 .28 .39 .33 .28 .38 .32 .28 .37 .31 .27 .26

7 .38 .30 .25 .37 .30 .25 .36 .29 .24 .34 .29 .24 .33 .28 .24 .22

8 .34 .27 .22 .34 .27 .22 .33 .26 .22 .32 .26 .22 .31 .25 .21 .20

9 .31 .24 .20 .31 .24 .20 .30 .24 .19 .29 .23 .19 .28 .23 .19 .18

10 .29 .22 .18 .28 .22 .18 .28 .22 .18 .27 .21 .18 .26 .21 .17 .16

Page 51: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Compact Fluorescent Lighting Fixtures

EVN Series

Wet Locations

NEMA 3,3R,4,4X,7,9

Type of Explosion-proof Technical Data

Electrical RatingsNon Sparking (Ex nR II T4 IP66)

Dust Ignition-proof (Ex DP II 11 IP66)Rated Voltage AC110V/ 220V/ 240V

Rated Wattage 13W×3, 18W×3, 26W×3

< EVNCL 1263 >

Rated Frequency 50Hz/ 60Hz

Entry Sizes 1/2", 3/4", 1"

Weight

Mounting Type Catalog No. Weight

Pendant EVNCL 1263 9 Kg

Standard Materials

Housing, mounting modules,

component pallets : Fiber glass

reinforced polyester resin

Globe :

Heat resistant hard glass

Gasket : Silicone rubber

Reflector :

Fiber glass Reinforced Polyester

External Hardware :

Stainless steel, Brass

Application Features Certification

EVN Series lighting fixtures are used ;

in manufacturing plants, refineries,

chemical, petrochemical and other

industrial process facilities,

wastewater and sewage treatment

plants, offshore, dockside and other

harbor installations as well as other

heavy industrial applications.

wherever the damaging effects of

water, wind, snow, sleet, hot sun or

any combination of these elements

are found.

in withstands the harshest of

corrosive environments.

to provide low wattage spot and

floodlighting.

where an explosive atmosphere

consisting of a mixture with air of

flammable substances in the form

of gas, vapour or mist is not likely

to occur in normal operation but, if

it does occur, will persist for a

short period only.

where combustible dust, moisture,

dirt are present and vibration,

corrosion, rough usage are

problems.

Enclosure in glass fiber reinforced

polyester resin, provide excellent

resistant to corrosion so have a

long life.

Enclosure contain ultraviolet

interception ingredient to resist

transformation.

Easy installation and maintenance

Internal type ballast.

Pendant mounting module

equipped with integral hub set

screws for vibration resistance.

Guard, hub inserts, stanchion

elbow and hardware made of

stainless steel for maximum

resistance to corrosion.

Grounding wire for safety.

Hinged assembly allows the

fixture to hang free during

installation to permit the use of

both hands when wiring.

Certified by KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas Safety

Corporation), and the others.

Compliance

IEC 60079-0, 15

NEMA 3, 3R, 4, 4X

Standard Finish

Dark Gray

If you want another color,

contact us please.

Options

With Dome Reflector or 30°

Angle Reflector with SMC or

High Grade Aluminium

If you need more information, contact us please. ⇨

Page 52: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number

Lamp Watt Hub Size Pendant Ceiling Bracket Stanchion Certification

Compact

Fluorescent

13W×31/2" EVNCL 1135 EVNCL 2135 EVNCL 3135 EVNCL 9135

Ex nR II T4

Ex DP II 12

3/4" EVNCL 1133 EVNCL 2133 EVNCL 3133 EVNCL 9133

18W×31/2" EVNCL 1185 EVNCL 2185 EVNCL 3185 EVNCL 9185

3/4" EVNCL 1183 EVNCL 2183 EVNCL 3183 EVNCL 9183

26W×31/2" EVNCL 1265 EVNCL 2265 EVNCL 3265 EVNCL 9265

3/4" EVNCL 1263 EVNCL 2263 EVNCL 3263 EVNCL 9263

Ordering Information EVN Lighting Fixture①

E VN C L 1 1 3 5 - DR Lamp Type②

① ② ③ ④ ⑤ ⑥ CL - Compact Fluorescent

Mounting Type③ Lamp Wattage (W)④ Entry Size⑤ Options⑥

1 - Pendant 13 - 13W×3 1 - 1" DR - Dome Reflector with SMC

2 - Ceiling 18 - 18W×3 3 - 3/4" AR - Angle Reflector with SMC

3 - Bracket 26 - 26W×3 5 - 1/2" C※ an order Aluminium Reflector instead of FRP

Reflector 9 - Stanchion

▞ Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

<EVNCL 2265-DR> 0 86.0 50 111

5 86.0 55 111Lamp : CFL26+ ×3 (5400 lm)

With Globe and without Guard+

Reflector : FRP Dome Reflector+

10 86.0 60 109

15 87.5 65 106

20 90.6 70 96.9

25 93.7 75 82.9

30 98.4 80 64.1

35 103 85 43.7

40 106 90 25.0

45 109

Coefficients of Utilization - Zonal Cavity

%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall

Reflectance(ρw)50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity Ratio

RCR20% Effective Floor Cavity Reflectance

0 .67 .67 .67 .66 .66 .66 .63 .63 .63 .60 .60 .60 .58 .58 .58 .57

1 .58 .56 .53 .57 .55 .53 .55 .53 .51 .52 .51 .49 .50 .49 .48 .47

2 .50 .46 .43 .49 .45 .42 .47 .44 .41 .45 .43 .40 .44 .41 .39 .38

3 .44 .39 .35 .43 .38 .35 .41 .37 .34 .40 .36 .33 .38 .35 .33 .32

4 .38 .33 .29 .38 .33 .29 .36 .32 .29 .35 .31 .28 .34 .30 .28 .27

5 .34 .29 .25 .34 .28 .25 .32 .28 .24 .31 .27 .24 .30 .27 .24 .23

6 .31 .25 .22 .30 .25 .21 .29 .25 .21 .28 .24 .21 .27 .24 .21 .20

7 .28 .23 .19 .27 .22 .19 .26 .22 .19 .25 .21 .19 .25 .21 .18 .17

8 .25 .20 .17 .25 .20 .17 .24 .20 .17 .23 .19 .17 .23 .19 .16 .15

9 .23 .18 .15 .23 .18 .15 .22 .18 .15 .21 .18 .15 .21 .17 .15 .14

10 .21 .17 .14 .21 .17 .14 .20 .16 .14 .20 .16 .14 .19 .16 .13 .12

Page 53: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Dimension

< EVN Bracket Type > < EVN Stanchion Type >

< EVN Pendant Type > < EVN Ceiling Type >

Page 54: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

H.I.D Lighting Fixtures

EU Series

Wet Locations

Factory Sealed

NEMA 3, 3R, 7

Type of Explosion-proof

Flameproof (Ex d IIB T4)

Dust Ignition-proof (Ex DP II 12)

< EU >

Application Features EU Series lighting fixtures are used;

in tunnels, building entrances

and similar locations where

moisture, dirt, chemicals or

rough usage are a problem.

in heavy process industries

having environments where

flammable or explosive vapors or

gases, or where combustible

dusts are present.

in areas where combustible dusts

and flammable vapors are

present simultaneously.

in hazardous areas, both indoors

and outdoors where long life

and low maintenance costs are

desired.

where high light output is

needed but space is limited.

where ignitable concentrations of

flammable gases, vapors, liquids

or dusts can exist some of the

time under normal operating

conditions.

Lighting unit and ballast are

constructed separately so as to

protect the ballast from the heat

of the lamp.

Lighting unit is screwed onto the

top of the mounting box and the

ballast to the side.

Globe assembly is securely

hinged to the body.

Ballast is a high quality one

maintaining much safety on

strength of enclosure,

weatherproof and temperature

rise.

Mounting box has four-way

conduit entries and a large

access cover for wiring.

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color,

contact us please.

Standard Materials Certification Compliance

Enclosure : Die casting aluminium

Globe : Heat resistant hard glass

Inner Reflector : High purity

aluminium

External Hardware : Stainless steel

Mounting Box : Cast aluminium alloy

Certified by KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas

Safety Corporation), and the

others.

IEC 60079-0, 1

NEMA 3, 3R, 7

IP 55

Technical Data Weight

Electrical Rating Mounting Type Catalog No. Weight

Rated Voltage AC110V/ 220V/ 240V ( See Below)※ Ceiling EUNL 32210 8.6 ㎏

Rated Wattage 50W/ 70W/ 100W

Rated Frequency 50Hz/ 60Hz

Entry Size 1/2", 3/4", 1"

Also you can order various voltage : ※

120V/ 208V/ 277V/ 460V

If you need more information, contact us please. ⇨

Page 55: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number

Lamp Watt Volts Pendant Ceiling90°

Bracket

40°

BracketCertification

High Pressure Sodium

50100-120 EUNL 31105 EUNL 32105 EUNL 33105 EUNL 34105

Ex d IIB T3

200-220 EUNL 31205 EUNL 32205 EUNL 33205 EUNL 34205

70100-120 EUNL 31107 EUNL 32107 EUNL 33107 EUNL 34107

200-220 EUNL 31207 EUNL 32207 EUNL 33207 EUNL 34207

100100-120 EUNL 31110 EUNL 32110 EUNL 33110 EUNL 34110

200-220 EUNL 31210 EUNL 32210 EUNL 33210 EUNL 34210

Metal Halide 100100-120 EUHL 31110 EUHL 32110 EUHL 33110 EUHL 34110

Ex d IIB T4200-220 EUHL 31210 EUHL 32210 EUHL 33210 EUHL 34210

Mercury Vapor 100100-120 EUML 31110 EUML 32110 EUML 33110 EUML 34110

200-220 EUML 31210 EUML 32210 EUML 33210 EUML 34210

* For Pole type, see pole section (2L-51)

Ordering Information Temperature Performance Data

E U N L 3 2 1 1 0 Lamp Ambient Flameproof Dust-Ignition

① ② ③ ④ ⑤ ⑥ Type Watt. Temp ( )℃ "d" "DP"

EU Lighting Fixture① Mounting Type④

H.I.D

5040 T4 12

1 - Pendant 55 - -

Lamp Type② 2 - Ceiling70

40 T4 12

NL - H.P.Sodium 3 - 90° Bracket 55 - -

HL - Metal Halide 4 - 40° Bracket 100

40 T4 12

ML - Mercury Vapor 55 - -

Voltage (V)⑤

Type of Lighting Fixture③ 1 - 100-120

3 - EUL Type 2 - 200-220

Wattage (W)⑥

05 - 50, 07 - 70, 10 - 100

Dimension

<Ceiling Type> <Pendant Type> <90° Bracket Type > <40° Bracket Type >

Page 56: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Photometric Data

Angle /1000㏅ ㏐ Angle /1000㏅ ㏐

<EUNL 32110> 0 93.7 50 107

5 76.8 55 112Lamp : NH100 (9000 lm)+

With Guard+ 10 77.8 60 116

15 81.5 65 125

20 76.8 70 131

25 77.8 75 132

30 81.5 80 133

35 87.2 85 139

40 91.9 90 143

45 99.4

Coefficients of Utilization - Zonal Cavity

Multipliers%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

(For use with

candlepower

curves only)

%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Lamp

Watts

Conversion

Factor

Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance

0 .85 .85 .85 .83 .83 .83 .79 .79 .79 .76 .76 .76 .73 .73 .73 .71

1 .71 .67 .63 .69 .66 .62 .66 .63 .60 .63 .61 .59 .61 .59 .57 .55

100 1 2 .59 .53 .48 .58 .52 .47 .55 .50 .46 .52 .48 .45 .50 .47 .44 .42

3 .50 .43 .37 .49 .42 .37 .46 .41 .36 .44 .39 .35 .42 .38 .34 .33

70 0.5 4 .43 .36 .30 .42 .35 .30 .40 .34 .29 .38 .33 .29 .37 .32 .28 .26

5 .38 .30 .25 .37 .30 .25 .35 .29 .24 .34 .28 .24 .32 .27 .24 .22

50 0.25 6 .34 .26 .21 .33 .26 .21 .31 .25 .21 .30 .25 .20 .29 .24 .20 .19

7 .30 .23 .18 .30 .23 .18 .28 .22 .18 .27 .22 .18 .26 .21 .18 .16

8 .27 .21 .16 .27 .20 .16 .26 .20 .16 .25 .20 .16 .24 .19 .16 .14

9 .25 .19 .14 .25 .18 .14 .24 .18 .14 .23 .18 .14 .22 .17 .14 .12

10 .23 .17 .13 .23 .17 .13 .22 .16 .13 .21 .16 .13 .21 .16 .13 .11

Angle /1000㏅ ㏐ Angle /1000㏅ ㏐

<EUHL 32110> 0 123 50 98.7

5 112 55 104Lamp : MH100 (6500 lm)+

With Guard+ 10 114 60 109

15 117 65 149

20 116 70 147

25 135 75 148

30 140 80 144

35 121 85 134

40 101 90 106

45 97.3

Coefficients of Utilization - Zonal Cavity%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance

0 .95 .95 .95 .93 .93 .93 .89 .89 .89 .85 .85 .85 .82 .82 .82 .80

1 .80 .76 .72 .78 .74 .71 .75 .72 .69 .72 .69 .67 .69 .67 .65 .63

2 .67 .61 .55 .66 .60 .54 .63 .58 .53 .60 .56 .52 .57 .54 .51 .49

3 .57 .50 .44 .56 .49 .43 .54 .47 .42 .51 .46 .41 .49 .45 .41 .39

4 .50 .42 .36 .49 .41 .35 .47 .40 .35 .45 .39 .34 .43 .38 .34 .32

5 .44 .36 .30 .43 .36 .30 .41 .35 .29 .40 .34 .29 .38 .33 .29 .27

6 .40 .32 .26 .39 .31 .26 .37 .30 .25 .36 .30 .25 .34 .29 .25 .23

7 .36 .28 .23 .35 .28 .23 .34 .27 .22 .33 .27 .22 .31 .26 .22 .20

8 .33 .25 .20 .32 .25 .20 .31 .25 .20 .30 .24 .20 .29 .24 .20 .18

9 .30 .23 .18 .30 .23 .18 .29 .22 .18 .28 .22 .18 .27 .22 .18 .16

10 .28 .21 .17 .27 .21 .17 .27 .21 .17 .26 .20 .16 .25 .20 .16 .15

Page 57: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

H.I.D Lighting Fixtures

EA Series

Wet Locations

Factory Sealed

NEMA 3, 3R, 7

< EA >

Type of Explosion-proof

Flameproof (Ex d IIB T4 H2)

Flameproof (Ex d IIC T4 H2)

Standard Materials

Enclosure : Die casting aluminium alloy

Globe : Heat resistant hard glass

Inner Reflector : High purity aluminium

Guard : Stainless steel

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

Application Features Globe assembly is securely hinged

to the body.

Easy installation and maintenance.

Hinged assembly allows the fixture

to hang free during installation to

permit the use of both hands

when wiring.

Can use compact fluorescent lamp

45W instead of HID lamp without

external ballast.

EA Series lighting fixture are used ;in heavy process industries having environments where flammable or explosive vapors or gases, or where combustible dusts are present.in paint spray booth suitability provides efficient, economical HID lighting for paint spray areas.in hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired. in hazardous locations requiring elevated ambient capability.in marine applications where water spray and corrosive atmospheres are considerations.

Lighting unit and ballast are constructed separately so as to protect the ballast from the heat of the lamp.Base of the body and the top of the globe holder have accurate tapered cylindrical surfaces and are secured by four socket head captive screw.Lighting unit is screwed onto the top of the mounting box and the ballast to the side.Pendant mounting module equipped with integral hub set screws for vibration resistance.Globe assembly is securely hinged to the body.

Compliance & Certification

IEC 60079-0, 1 NEMA 3, 3R, 7IP 55Certified by KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others.

Technical Data Lamp Replacement

Electrical Rating

Rated Voltage AC110V/ 220V/ 240V ( See Below)※

Rated Wattage 100W/ 150W/ 175W/ 200W/ 250W/ 400W

Rated Frequency 50Hz/ 60Hz

Entry Size 1/2", 3/4", 1"

Also you can order various voltage : ※

110V/ 120V/ 208V/ 220V/ 240V/ 277V/ 460V

Weight

Mounting Type Catalog No. Weight

Small (Ceiling) EANL 2215 17.3 ㎏

Large (Ceiling) EAML 2240 28.3 ㎏

If you need more information, contact us please.☞

Page 58: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number

Lamp Watt Pendant Ceiling 90° Bracket 40° Bracket Certification

High

Pressure

Sodium

150 EANL 2115 EANL 2215 EANL 2315 EANL 2415

Ex d IIC T4200 EANL 2120 EANL 2220 EANL 2320 EANL 2420

250 EANL 2125 EANL 2225 EANL 2325 EANL 2425

400 EANL 2140 EANL 2240 EANL 2340 EANL 2440 Ex d IIB T3

Metal

Halide

175 EAHL 2117 EAHL 2217 EAHL 2317 EAHL 2417Ex d IIC T4

250 EAHL 2125 EAHL 2225 EAHL 2325 EAHL 2425

400 EAHL 2140 EAHL 2240 EAHL 2340 EAHL 2440 Ex d IIB T3

Mercury

Vapor

200 EAML 2120 EAML 2220 EAML 2320 EAML 2420Ex d IIC T4

250 EAML 2125 EAML 2225 EAML 2325 EAML 2425

400 EAML 2140 EAML 2240 EAML 2340 EAML 2440 Ex d IIB T3

Dimension Ordering Information

<Ceiling Type>

<Pendant Type>

<40°Bracket Type>

<90°Bracket Type>

E A N L 2 1 1 5 ① ② ③ ④ ⑤

EA Lighting Fixture① Mounting Type④

1 - Pendant

2 - Ceiling

Lamp Type② 3 - 90° Bracket

NL - High Pressure Sodium 4 - 40° Bracket

HL - Metal Halide

ML - Mercury Vapour ⑤ Lamp Wattage(w)

15 - 150

17 - 175

Model Type③ 20 - 200

2 - EA Type 25 - 250

40 - 400

Temperature Performance Data

Lamp Ambient Flame

Type Watt. Temp ( )℃ Proof "d"

High

Pressure

Sodium

15040 T4

55 T4

20040 T4

55 T4

25040 T4

55 T4

40040 T3

55 T3

Metal

Halide

17540 T4

55 T4

25040 T4

55 T4

40040 T3

55 T3

Mercury

Vapor

20040 T4

55 T4

25040 T4

55 T4

40040 T3

55 T3

Page 59: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

0 122 50 161<EAHL 2225>5 108 55 171

Lamp : MH250 (20500 lm)+

With Globe and without Guard+10 94.4 60 164

15 105 65 126

20 143 70 115

25 170 75 112

30 147 80 80.4

35 133 85 38.4

40 129 90 17.4

45 133

Coefficients of Utilization - Zonal Cavity

Multipliers(For use with candlepower curves only)

%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall

Reflectance(ρw)50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Lamp

Watts

Conversion

Factor

Room Cavity Ratio

RCR20% Effective Floor Cavity Reflectance

0 .89 .89 .89 .87 .87 .87 .83 .83 .83 .79 .79 .79 .76 .76 .76 .74

1 .77 .74 .71 .76 .73 .70 .72 .70 .68 .70 .68 .66 .67 .65 .64 .62

250 1 2 .67 .62 .58 .66 .61 .57 .63 .59 .56 .61 .57 .54 .58 .56 .53 .52

3 .59 .53 .48 .58 .52 .47 .55 .50 .46 .53 .49 .46 .51 .48 .45 .43

175 0.68 4 .52 .45 .40 .51 .45 .40 .49 .44 .39 .47 .42 .39 .46 .41 .38 .36

5 .46 .39 .34 .45 .39 .34 .44 .38 .34 .42 .37 .33 .41 .36 .33 .31

6 .41 .35 .30 .41 .34 .30 .39 .34 .29 .38 .33 .29 .37 .32 .29 .27

7 .38 .31 .26 .37 .31 .26 .36 .30 .26 .35 .30 .26 .34 .29 .26 .24

8 .34 .28 .23 .34 .28 .23 .33 .27 .23 .32 .27 .23 .31 .26 .23 .21

9 .31 .25 .21 .31 .25 .21 .30 .25 .21 .29 .24 .21 .29 .24 .21 .19

10 .29 .23 .19 .29 .23 .19 .28 .23 .19 .27 .22 .19 .27 .22 .19 .17

Angle cd/1000 lm Angle cd/1000 lm

0 172 50 118<EANL 2225>

5 135 55 125Lamp : NH250 (25000 lm)+

With Globe and without Guard+ 10 94.5 60 125

15 105 65 125

20 142 70 108

25 182 75 87.8

30 142 80 67.5

35 108 85 50.6

40 97.9 90 30.4

45 101

Coefficients of Utilization - Zonal Cavity

Multipliers(For use with

candlepower

curves only)

%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall

Reflectance(ρw)50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Lamp

Watts

Conversion

Factor

Room Cavity Ratio

RCR20% Effective Floor Cavity Reflectance

0 .89 .89 .89 .87 .87 .87 .83 .83 .83 .79 .79 .79 .76 .76 .76 .74

1 .77 .74 .71 .76 .73 .70 .72 .70 .68 .70 .68 .66 .67 .65 .64 .62

250 1 2 .67 .62 .58 .66 .61 .57 .63 .59 .56 .61 .57 .54 .58 .56 .53 .52

3 .59 .53 .48 .58 .52 .47 .55 .50 .46 .53 .49 .46 .51 .48 .45 .43

200 0.8 4 .52 .45 .40 .51 .45 .40 .49 .44 .39 .47 .42 .39 .46 .41 .38 .36

5 .46 .39 .34 .45 .39 .34 .44 .38 .34 .42 .37 .33 .41 .36 .33 .31

150 0.56 6 .41 .35 .30 .41 .34 .30 .39 .34 .29 .38 .33 .29 .37 .32 .29 .27

7 .38 .31 .26 .37 .31 .26 .36 .30 .26 .35 .30 .26 .34 .29 .26 .24

8 .34 .28 .23 .34 .28 .23 .33 .27 .23 .32 .27 .23 .31 .26 .23 .21

9 .31 .25 .21 .31 .25 .21 .30 .25 .21 .29 .24 .21 .29 .24 .21 .19

10 .29 .23 .19 .29 .23 .19 .28 .23 .19 .27 .22 .19 .27 .22 .19 .17

Page 60: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Compact Fluorescent Lighting Fixtures

EA Series

Wet Locations

Factory Sealed

NEMA 3, 3R, 7

< EACL >

Type of Explosion-proof

Flameproof (Ex d IIC T6)

Standard Materials

Enclosure : Die casting aluminium alloy

Globe : Heat resistant hard glass

Inner Reflector : High purity aluminium

Guard : Stainless steel

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

Application Features

Compliance & CertificationEA Series lighting fixtures are used ;

in heavy process industries

having environments where

flammable or explosive vapors

or gases, or where combustible

dusts are present

in paint spray booth suitability

provides efficient, economical

HID lighting for paint spray

areas

in hazardous areas, both

indoors and outdoors where

long life and low maintenance

costs are desired

in hazardous locations requiring

elevated ambient capability

in marine applications where

water spray and corrosive

atmospheres are considerations

Base of the body and the top of

the globe holder have accurate

tapered cylindrical surfaces and

are secured by four socket head

captive screw

Globe assembly is securely

hinged to the body

Lighting unit is screwed onto the

top of the mounting box

Easy installation and

maintenance

Pendant mounting module

equipped with integral hub set

screws for vibration resistance.

Hinged assembly allows the

fixture to hang free during

installation to permit the use of

both hands when wiring.

Can use HID lamps instead of

compact fluorescent lamp with

external ballast.

IEC 60079-0, 1

NEMA 3, 3R, 7

IP 55

Certified by KOSHA (Korea

Occupational Safety & Health

Agency), KGS(Korea Gas Safety

Corporation), and the others.

Technical Data

Electrical Rating

Rated Voltage AC110V/ 220V/ 240V

Rated Wattage Compact Fluorescent 45W

Rated Frequency 50Hz/ 60Hz

Entry Size 1/2", 3/4", 1"

Weight

Mounting Type Catalog No. Weight

Ceiling EACL 2204 9.5 ㎏

If you need more information, contact us please. ⇨

Page 61: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Dimension Ordering Number

<Ceiling Type>

<Pendant Type>

<40°Bracket Type>

<90°Bracket Type>

Lamp Compact Fluorescent

Watt 45 55

Mounting

Type

Pendant EACL 2104 EACL 2105

Ceiling EACL 2204 EACL 2205

90° Bracket EACL 2304 EACL 2305

40° Bracket EACL 2404 EACL 2405

Certification Ex d IIC T6

Ordering Information

E A C L 2 1 0 4 ① ② ③ ④ ⑤

EA Lighting Fixture① Mounting④

1 - Pendant

2 - Ceiling

Lamp Type② 3 - 90° Bracket

CL - Compact Fluorescent 4 - 40° Bracket

Model Type③ Lamp Wattage⑤

2 - EA Type 04 - 45

Temperature Performance Data

Lamp Ambient Flame

Type Watt. Temp ( )℃ Proof "d"

Compact

Fluorescent

4540 85 (T6)

55 -

5540 85 (T6)

55 -

7040 85 (T6)

55 -

Page 62: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

<EACL 2104> 0 101 50 95.8

5 101 55 95.8Lamp : CFL45W (3000 lm)+

With Globe and without Guard+ 10 98.6 60 93.2

15 85.1 65 87.6

20 93.2 70 78.3

25 112 75 72.9

30 112 80 56.7

35 101 85 47.3

40 95.8 90 39.2

45 98.6

Coefficients of Utilization - Zonal Cavity

%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall

Reflectance(ρw)50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity Ratio

RCR20% Effective Floor Cavity Reflectance

0 .63 .63 .63 .61 .61 .61 .59 .59 .59 .56 .56 .56 .54 .54 .54 .53

1 .54 .52 .50 .53 .51 .49 .51 .49 .47 .49 .47 .46 .47 .46 .44 .43

2 .47 .43 .40 .46 .42 .39 .44 .41 .38 .42 .40 .38 .41 .39 .37 .35

3 .41 .36 .33 .40 .36 .32 .38 .35 .32 .37 .34 .31 .36 .33 .31 .30

4 .36 .31 .28 .35 .31 .27 .34 .30 .27 .33 .29 .27 .32 .29 .26 .25

5 .32 .27 .24 .32 .27 .24 .30 .26 .23 .29 .26 .23 .28 .25 .23 .22

6 .29 .24 .21 .29 .24 .21 .28 .23 .20 .27 .23 .20 .26 .23 .20 .19

7 .26 .22 .18 .26 .21 .18 .25 .21 .18 .24 .21 .18 .24 .20 .18 .17

8 .24 .20 .16 .24 .19 .16 .23 .19 .16 .22 .19 .16 .22 .18 .16 .15

9 .22 .18 .15 .22 .18 .15 .21 .17 .15 .21 .17 .15 .20 .17 .15 .14

10 .21 .16 .14 .20 .16 .14 .20 .16 .13 .19 .16 .13 .19 .16 .13 .12

Page 63: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

H.I.D Lighting Fixtures

EVS Series

Wet Locations

NEMA 3, 3R, 7

Type of Explosion-proof

Flameproof-Increase Safety

(Ex de IIC T3 IP66)

Application Features

EVS Series HID lighting fixture are used ;

in Heavy process industries having environments

where flammable or explosive vapors or gases, or

where combustible dusts are present.

in Hazardous areas, both indoors and outdoors

where long life and low maintenance costs are

desired.

in Petroleum refineries, chemical, petrochemical

and other heavy process industry facilities.

in Paint spray booth suitability provides efficient,

economical HID lighting for paint spray areas.

in Hazardous locations requiring elevated ambient

capability.

in installations where moisture, dirt, dust, vibration,

corrosion and rough usage are problems.

where ignitable concentrations of flammable gases,

vapors or liquids can exist all of the time or some

of the time under normal operation conditions.

Fixture is factory wired; power is fed through "wireless"

connection block which serves as a mechanical seal

between conduit and ballast compartments, eliminating

the need for a field installed seal. The result is fast,

easy installation, lowest installed cost, easy

maintenance.

Dome and 30°angle reflectors made of SMC material

won't rust, corrode, dent, chip or peel.

Four mounting arrangements to suit any lighting

layout-pendant, ceiling, wall bracket and stanchion.

Internal ballasts-separate ballasts are not required. High

power factor (90%) ballasts reduce power costs-allow

more fixtures per circuit.

Factory sealed, porcelain with mogul or medium base

socket.

Wide range of light sources to meet specific lighting

needs - High Pressure Sodium (HPS): 50, 70, 100,

150, 200, 250 and 400W, Mercury Vapour (MV): 100,

200, 250 and 400W, Metal Halide (MH): 100, 175, 250

and 400W.

Standard Materials Compliance

Enclosure : Die casting

aluminium

Globe : Heat resistant hard glass

Lamp socket : Porcelain with

screw shell

Reflector : Fiberglass Reinforced

Polyester

External Hardware : Stainless

steel

IEC 60079-0, 1, 7

NEMA 3, 3R, 7

Certification

Certified by KOSHA (Korea

Occupational Safety & Health

Agency), KGS(Korea Gas Safety

Corporation), and the others.

Options Standard Finish With Dome Reflector or 30°

Angle Reflector made of FRP

With Choke or Lead Peak type

Ballast.

MUNSELL No. 7.5BG 6/1.5

If you want another color,

contact us please.

< EVS >

Technical Data

Electrical Rating

Rated Voltage AC110V/ 220V/ 240V ( See Below) ※

Rated Wattage50W/ 70W/ 100W/ 150W/

175W/ 200W/ 250W/ 400W Weight

Rated Frequency 50Hz/ 60Hz Catalog No. Weight

Entry Size 1/2", 3/4", 1" EVSHL 3255 16.9 ㎏

Also you can order various voltage : ※

120V/ 208V/ 277V/ 460V

If you need more information, contact us please. ⇨

Page 64: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number

Lamp WattHub

SizePendant Ceiling Bracket Stanchion Certification

High

Pressure

Sodium

501/2" EVSNL 1055 EVSNL 2055 EVSNL 3055 EVSNL 4055

Ex de IIC T3

3/4" EVSNL 1053 EVSNL 2053 EVSNL 3053 EVSNL 4053

701/2" EVSNL 1075 EVSNL 2075 EVSNL 3075 EVSNL 4075

3/4" EVSNL 1073 EVSNL 2073 EVSNL 3073 EVSNL 4073

1001/2" EVSNL 1105 EVSNL 2105 EVSNL 3105 EVSNL 4105

3/4" EVSNL 1103 EVSNL 2103 EVSNL 3103 EVSNL 4103

1501/2" EVSNL 1155 EVSNL 2155 EVSNL 3155 EVSNL 4155

3/4" EVSNL 1153 EVSNL 2153 EVSNL 3153 EVSNL 4153

2001/2" EVSNL 1205 EVSNL 2205 EVSNL 3205 EVSNL 4205

3/4" EVSNL 1203 EVSNL 2203 EVSNL 3203 EVSNL 4203

2501/2" EVSNL 1255 EVSNL 2255 EVSNL 3255 EVSNL 4255

3/4" EVSNL 1253 EVSNL 2253 EVSNL 3253 EVSNL 4253

4001/2" EVSNL 1405 EVSNL 2405 EVSNL 3405 EVSNL 4405

3/4" EVSNL 1403 EVSNL 2403 EVSNL 3403 EVSNL 4403

Metal

Halide

1001/2" EVSHL 1105 EVSHL 2105 EVSHL 3105 EVSHL 4105

3/4" EVSHL 1103 EVSHL 2103 EVSHL 3103 EVSHL 4103

1751/2" EVSHL 1175 EVSHL 2175 EVSHL 3175 EVSHL 4175

3/4" EVSHL 1173 EVSHL 2173 EVSHL 3173 EVSHL 4173

2501/2" EVSHL 1255 EVSHL 2255 EVSHL 3255 EVSHL 4255

3/4" EVSHL 1253 EVSHL 2253 EVSHL 3253 EVSHL 4253

4001/2" EVSNL 1405 EVSNL 2405 EVSNL 3405 EVSNL 4405

Ex de IIC T23/4" EVSNL 1403 EVSNL 2403 EVSNL 3403 EVSNL 4403

Mercury

Vapor

1001/2" EVSML 1105 EVSML 2105 EVSML 3105 EVSML 4105

Ex de IIC T3

3/4" EVSML 1103 EVSML 2103 EVSML 3103 EVSML 4103

2001/2" EVSML 1205 EVSML 2205 EVSML 3205 EVSML 4205

3/4" EVSML 1203 EVSML 2203 EVSML 3203 EVSML 4203

2501/2" EVSML 1255 EVSML 2255 EVSML 3255 EVSML 4255

3/4" EVSML 1253 EVSML 2253 EVSML 3253 EVSML 4253

4001/2" EVSML 1405 EVSML 2405 EVSML 3405 EVSML 4405

3/4" EVSML 1403 EVSML 2403 EVSML 3403 EVSML 4403

Ordering Information

E V S N L 1 0 7 5 - DR ① ② ③ ④ ⑤ ⑥

EVS Lighting Fixture① Lamp Type② Mounting Type③ Lamp Wattage (W)④

NL - High Pressure Sodium 1 - Pendant 05 - 50

HL- Metal Halide 2 - Ceiling 07 - 70

ML - Mercury Vapour 3 - Bracket 10 - 100

4 - Stanchion 15 - 150

Entry Size⑤ Options⑥ 17 - 175

1 - 1" DR - Dome Type Reflector 20 - 200

3 - 3/4" AR - Angle Type Reflector 25 - 250

5 - 1/2" 40 - 400

Page 65: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

0 132.6 50 116.5

5 126.8 55 116.1<EVSHL17C1-SD>10 124.6 60 121.4

Lamp : MH175 (14000 lm)+

With Guard+15 123.7 65 131.7

20 118.3 70 129.5

25 116.1 75 83.0

30 118.8 80 33.0

35 113.8 85 20.5

40 107.1 90 8.5

45 109.4

Dimension

< EVS Ceiling Type> < EVS Pendant Type>

< EVS Bracket Type > < EVS Stanchion Type >

A B C D E

100W Ø255 455 445 470 480

250W Ø270 520 510 535 545

400W Ø270 565 555 580 590

Page 66: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

H.I.D Lighting Fixtures

EG Series

Wet Locations

Marine Locations

NEMA 3,3R,4,4X,7

Type of Explosion-proof

<EG>

Class I Division 1 Group C,D

Flameproof (Ex d IIC T4 IP66)

Dust Ignition-proof (Ex DP II 12)

Application

EG Series HID lighting fixtures are used ;

in heavy process industries having environments where flammable or

explosive vapors or gases, or where combustible dusts are present.

in hazardous areas, both indoors and outdoors where long life and low

maintenance costs are desired.

in petroleum refineries, chemical, petrochemical and other heavy process

industry facilities.

in paint spray booth suitability provides efficient, economical HID lighting

for paint spray areas.

where ignitable concentrations of flammable gases, vapors or liquids can

exist all of the time or some of the time under normal operation

conditions.

in hazardous locations requiring elevated ambient capability.

in installations where moisture, dirt, dust, vibration, corrosion and rough

usage are problems.

Fixture Wattage

<EGS>

Lamp EG Series Wattage

Type EGS EG

HPS 50, 70, 100 150, 200, 250, 400

MH 100 175, 250, 400

MV 100 200, 250, 400

Features

Fixture is factory wired; power is fed through "wireless" connection block

which serves as a mechanical seal between conduit and ballast

compartments, eliminating the need for a field installed seal. The result is

fast, easy installation, lowest installation cost, easy maintenance.

Dome and 30°angle reflectors made of SMC material won't rust, corrode,

dent, chip or peel.

Internal ballasts-separate ballasts are not required. High power factor (90%)

ballasts reduce power costs-allow more fixtures per circuit.

Factory sealed, porcelain with mogul or medium base socket.

Wide range of light sources to meet specific lighting needs - High Pressure

Sodium (HPS): 50, 70, 100, 150, 200, 250 and 400W, Mercury Vapour (MV):

100, 200, 250 and 400W, Metal Halide (MH): 100, 175, 250 and 400W.

If you need more information, contact us please. ⇨

Page 67: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

H.I.D Lighting Fixtures

EGS Series

Wet Locations

Marine Locations

NEMA 3,3R,4,4X,7

<EGS>

Type of Explosion-proof

Flameproof (Ex d IIC T4 IP66)

Features

Compact, lightweight design is ideal for

medium and low mounting heights.

Dome and 30°angle reflectors made of SMC

material won't rust, corrode, dent, chip or

peel.

Wide range of light sources to meet specific

lighting needs - 50, 70 and 100W High

Pressure Sodium (HPS); 100W Mercury Vapour

(MV) and Metal Halide (MH).

Standard Materials

Enclosure : Die casting aluminium

Globe : Heat resistant hard glass

Lamp socket : Porcelain with screw shell

Reflector : Fiber glass Reinforced polyester

Guard : Die casting aluminium

Technical Data

Electrical Rating

Rated Voltage AC110V/ 220V/ 240V ( See Below)※

Rated Wattage 50W/ 70W/ 100W

Rated Frequency 50Hz/ 60Hz

Entry Size 1/2", 3/4", 1"Standard Finish

Also you can order various voltage : ※

120V/ 208V/ 277V/ 460VMUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

WeightCompliance & CertificationMounting Type Catalog No. WeightIEC 60079-0, 1

NEMA 3, 3R, 4, 4X, 7

Certified by KOSHA (Korea Occupational

Safety & Health Agency), KGS (Korea Gas

Safety Corporation), and the others.

Ceiling EGSNL 2101 11.4 ㎏

Option

With Dome Reflector or 30° Angle Reflector

made of FRP

If you need more information, contact us please. ⇨

Page 68: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number

Lamp WattHub

SizePendant Ceiling Bracket Stanchion Certification

High

Pressure

Sodium

501" EGSNL 1051 EGSNL 2051 EGSNL 3051 EGSNL 4051

Ex d IIC T4 IP66

3/4" EGSNL 1053 EGSNL 2053 EGSNL 3053 EGSNL 4053

1/2" EGSNL 1055 EGSNL 2055 EGSNL 3055 EGSNL 4055

701" EGSNL 1071 EGSNL 2071 EGSNL 3071 EGSNL 4071

3/4" EGSNL 1073 EGSNL 2073 EGSNL 3073 EGSNL 4073

1/2" EGSNL 1075 EGSNL 2075 EGSNL 3075 EGSNL 4075

1001" EGSNL 1101 EGSNL 2101 EGSNL 3101 EGSNL 4101

3/4" EGSNL 1103 EGSNL 2103 EGSNL 3103 EGSNL 4103

1/2" EGSNL 1105 EGSNL 2105 EGSNL 3105 EGSNL 4105

Metal

Halide100

1" EGSHL 1101 EGSHL 2101 EGSHL 3101 EGSHL 4101

3/4" EGSHL 1103 EGSHL 2103 EGSHL 3103 EGSHL 4103

1/2" EGSHL 1105 EGSHL 2105 EGSHL 3105 EGSHL 4105

Mercury

Vapor100

1" EGSML 1101 EGSML 2101 EGSML 3101 EGSML 4101

3/4" EGSML 1103 EGSML 2103 EGSML 3103 EGSML 4103

1/2" EGSML 1105 EGSML 2105 EGSML 3105 EGSML 4105

Ordering Information Temperature Performance Data

E G S N L 1 1 0 1 / 4 - DR Lamp AmbientFlameproof "d"

① ② ③ ④ ⑤ ⑥ ⑦ Type Watt Temp ( )℃

High

Pressure

Sodium

5040 T4

EGS Lighting Fixture① Entry Size⑤ 55 T4

1 - 1"70

40 T4

Lamp Type② 3 - 3/4" 55 T4

NL - High Pressure Sodium 5 - 1/2"100

40 T4

HL - Metal Halide 55 T4

ML - Mercury Vapour Input Voltage (V)⑥ Metal

Halide100

40 T4

1 - 110 55 T4

Mounting Type③ 2 - 120 Mercury

Vapor100

40 T4

1 - Pendant 3 - 208 55 T4

2 - Ceiling 4 - 220

3 - Bracket 5 - 240

4 - Stanchion 6 - 277

7 - 460

Lamp Wattage (W)④

05 - 50 Options⑦

07 - 70 DR - Dome Type Reflector

10 - 100 AR - Angle Type Reflector

Dimension

< EGS Bracket Type > < EGS Stanchion Type > < EGS Ceiling Type > < EGS Pendant Type >

Page 69: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

<EGSNL 1101/4 - DR> 0 233 50 194

5 216 55 180Lamp : NH100 (9000 lm)+

With Globe +

Reflector : +

FRP Dome Reflector

10 212 60 163

15 193 65 132

20 194 70 67.5

25 195 75 32.8

30 198 80 21.6

35 200 85 10.3

40 201 90 5.7

45 202

Coefficients of Utilization - Zonal Cavity

Multipliers%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

(For use with

candlepower

curves only)

%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance

Lamp

Watts

Conversion

Factor0 .94 .94 .94 .91 .91 .91 .87 .87 .87 .84 .84 .84 .80 .80 .80 .79

1 .83 .80 .78 .82 .79 .76 .78 .76 .74 .75 .73 .72 .72 .71 .70 .68

100 1 2 .75 .70 .66 .73 .69 .65 .70 .67 .67 .68 .65 .62 .66 .63 .61 .59

3 .67 .61 .57 .66 .60 .56 .63 .59 .55 .61 .58 .54 .59 .56 .53 .52

70 0.5 4 .60 .54 .49 .59 .53 .49 .57 .52 .48 .55 .51 .48 .54 .50 .47 .46

5 .54 .48 .43 .53 .48 .43 .52 .47 .43 .50 .46 .42 .49 .45 .42 .40

50 0.25 6 .49 .43 .38 .49 .43 .38 .47 .42 .38 .46 .41 .38 .45 .41 .37 .36

7 .45 .39 .34 .45 .39 .34 .43 .38 .34 .42 .37 .34 .41 .37 .34 .32

8 .41 .35 .31 .41 .35 .31 .40 .35 .31 .39 .34 .31 .38 .34 .30 .29

9 .38 .32 .28 .38 .32 .28 .37 .32 .28 .36 .31 .28 .35 .31 .28 .26

10 .36 .30 .26 .35 .30 .26 .34 .29 .26 .34 .29 .26 .33 .29 .26 .24

Angle cd/1000 lm Angle cd/1000 lm

<EGSHL 1101/4 - DR> 0 227 50 149

5 214 55 154Lamp : MH100 (6500 lm)+

With Globe +

Reflector : +

FRP Dome Reflector

10 199 60 116

15 173 65 55.9

20 169 70 38.9

25 164 75 24.7

30 169 80 14.3

35 183 85 20.8

40 197 90 13.0

45 150

Coefficients of Utilization - Zonal Cavity%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance

0 .74 .74 .74 .72 .72 .72 .69 .69 .69 .66 .66 .66 .63 .63 .63 .62

1 .65 .63 .61 .64 .62 .60 .61 .60 .58 .59 .57 .56 .57 .56 .54 .53

2 .59 .55 .52 .58 .54 .51 .55 .53 .50 .53 .51 .49 .52 .50 .48 .47

3 .53 .48 .45 .52 .48 .45 .50 .47 .44 .49 .46 .43 .47 .45 .42 .41

4 .48 .43 .40 .47 .43 .39 .46 .42 .39 .44 .41 .38 .43 .40 .38 .37

5 .44 .39 .35 .43 .38 .35 .42 .38 .35 .41 .37 .34 .39 .36 .34 .33

6 .40 .35 .31 .39 .35 .31 .38 .34 .31 .37 .34 .31 .36 .33 .31 .29

7 .37 .32 .28 .36 .32 .28 .35 .31 .28 .34 .31 .28 .34 .30 .28 .27

8 .34 .29 .26 .33 .29 .26 .33 .29 .26 .32 .28 .25 .31 .28 .25 .24

9 .31 .27 .24 .31 .27 .24 .30 .26 .23 .30 .26 .23 .29 .26 .23 .22

10 .29 .25 .22 .29 .25 .22 .28 .24 .22 .28 .24 .22 .27 .24 .22 .21

Page 70: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

H.I.D Lighting Fixtures

EG Series

Wet Locations

Marine Locations

NEMA 3,3R,4,4X,7

Type of Explosion-proof

Class I Division 1 Group C,D

Flameproof (Ex d IIC T4 IP66)

Dust Ignition-proof (Ex DP II 12)

Features

<EG>

Options

Internal ballasts-separate ballasts

are not required. High power

factor (90%) ballasts reduce

power costs-allow more fixtures

per circuit.

Wide range of light sources to

meet specific lighting needs -

High Pressure Sodium (HPS):

150, 200, 250 and 400W,

Mercury Vapour (MV): 200, 250

and 400W, Metal Halide (MH):

175, 250 and 400W.

With Dome Reflector or 30°

Angle Reflector made of SMC

Instant Restrike (Max 150W HPS

only)

Fused to protect ballast and

capacitors

Quartz Auxiliary Lighting come to

full brightness immediately

(Non-hazardous location only,

Not available for use with 400W

MH or MV)

Standard Materials Compliance & Certification

Enclosure :

Die casting aluminium

Globe : Heat resistant hard glass

Lamp socket :

Porcelain with screw shell

Reflector :

Fiber glass Reinforced Polyester

Guard : Die casting aluminium

NEC - Class I Division 1 Group

C,D

UL 844 - Lighting Fixtures for

Use in Hazardous (Classified)

Locations

IEC 60079-0, 1

NEMA 3, 3R, 4, 4X, 7

Standard Finish Certification

MUNSELL No. 7.5BG 6/1.5

If you want another color,

contact us please.

UL Listed File No. E 131747

Certified by UL (Underwriters

Laboratories Inc), KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas Safety

Corporation), and the others.

Technical Data Weight

Electrical Rating Mounting Type Catalog No. Weight

Rated Voltage AC110V/ 220V/ 240V 250W Ceiling EGNL 2251 21.9 ㎏

(Max. 460V for UL Listed) 400W Ceiling EGNL 2401 25.5 ㎏

Rated Wattage 150W/ 175W/ 200W/ 250W/

400W (Max 250W for UL Listed)

Rated Frequency 50Hz/ 60Hz

Entry Size 1/2", 3/4", 1"

If you need more information, contact us please. ⇨

Page 71: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number

Lamp WattHub

SizePendant Ceiling Bracket Stanchion Certification

High

Pressure

Sodium

1501" EGNL 1151 EGNL 2151 EGNL 3151 EGNL 4151

Ex d IIC T4, Ex DP II 11,

Class I Division I Group C,D

3/4" EGNL 1153 EGNL 2153 EGNL 3153 EGNL 4153

2001" EGNL 1201 EGNL 2201 EGNL 3201 EGNL 4201

3/4" EGNL 1203 EGNL 2203 EGNL 3203 EGNL 4203

2501" EGNL 1251 EGNL 2251 EGNL 3251 EGNL 4251

3/4" EGNL 1253 EGNL 2253 EGNL 3253 EGNL 4253

4001" EGNL 1401 EGNL 2401 EGNL 3401 EGNL 4401

Ex d IIC T33/4" EGNL 1403 EGNL 2403 EGNL 3403 EGNL 4403

Metal

Halide

1751" EGHL 1171 EGHL 2171 EGHL 3171 EGHL 4171

Ex d IIC T4, Ex DP II 11,

Class I Division I Group C,D

3/4" EGHL 1173 EGHL 2173 EGHL 3173 EGHL 4173

2501" EGHL 1251 EGHL 2251 EGHL 3251 EGHL 4251

3/4" EGHL 1253 EGHL 2253 EGHL 3253 EGHL 4253

4001" EGHL 1401 EGHL 2401 EGHL 3401 EGHL 4401

Ex d IIC T2, Ex DP II 123/4" EGHL 1403 EGHL 2403 EGHL 3403 EGHL 4403

Mercury

Vapor

2001" EGML 1201 EGML 2201 EGML 3201 EGML 4201

Ex d IIC T3, Ex DP II 11,

Class I Division I Group C,D

3/4" EGML 1203 EGML 2203 EGML 3203 EGML 4203

2501" EGML 1251 EGML 2251 EGML 3251 EGML 4251

3/4" EGML 1253 EGML 2253 EGML 3253 EGML 4253

4001" EGML 1401 EGML 2401 EGML 3401 EGML 4401

Ex d IIC T33/4" EGML 1403 EGML 2403 EGML 3403 EGML 4403

Ordering Information Temperature Performance Data

E G N L 1 1 5 1 / 4 - DR Lamp Ambient Class I Flame Dust Ignition

① ② ③ ④ ⑤ ⑥ ⑦Type Watt. Temp ( )℃ Div. 1 Proof "d" Proof "DP"

EG Lighting Fixture① Entry Size⑤

High

Pressure

Sodium

15040 120 (T4A) T4 11

1 - 1" 55 - T4 -

3 - 3/4"200

40 120 (T4A) T4 11

Lamp Type② 5 - 1/2" 55 - T4 -

NL - High Pressure Sodium250

40 120 (T4A) T4 11

HL - Metal Halide 55 - T4 -

ML - Mercury Vapour Input Voltage (V)⑥ 400

40 - T3 -

1 - 110 55 - T3 -

2 - 120

Metal

Halide

17540 120 (T4A) T3 11

Mounting Type③ 3 - 208 55 - T3 -

1 - Pendant 4 - 220250

40 120 (T4A) T3 11

2 - Ceiling 5 - 240 55 - T3 -

3 - Bracket 6 - 277400

40 - T2 12

4 - Stanchion 7 - 460 55 - T2 -

Mercury

Vapor

20040 120 (T4A) T3 11

55 - T3 -

Lamp Wattage (W)④ Options⑦ 250

40 120 (T4A) T3 11

15 - 150 DR - Dome Type Reflector 55 - T3 -

17 - 175 AR - Angle Type Reflector400

40 - T3 -

20 - 200 IR - Instant Restrike Type 55 - T3 -

25 - 250 FU - Fused Type

40 - 400 QAL - Quartz Auxiliary Lighting Type

Page 72: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

0 152 50 126<EGNL 1251/4 - DR>

5 148 55 128Lamp : NH250 (25000 lm)+

With Globe +

Reflector : FRP Dome +

Reflector

10 141 60 141

15 135 65 149

20 134 70 147

25 137 75 112

30 135 80 72.4

35 132 85 32.7

40 127 90 13.8

45 124

Coefficients of Utilization - Zonal Cavity

Multipliers%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

(For use with candlepower curves only)

%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Lamp

Watts

Conversion

Factor

Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance

0 .85 .85 .85 .83 .83 .83 .79 .79 .79 .76 .76 .76 .73 .73 .73 .71

1 .74 .70 .68 .72 .69 .67 .69 .67 .64 .66 .64 .62 .64 .62 .61 .59

250 1 2 .64 .59 .55 .63 .58 .54 .60 .56 .53 .58 .54 .52 .55 .53 .50 .49

3 .56 .50 .45 .55 .49 .45 .52 .48 .44 .50 .46 .43 .49 .45 .42 .41

200 0.8 4 .49 .43 .38 .48 .42 .37 .46 .41 .37 .45 .40 .36 .43 .39 .36 .34

5 .44 .37 .32 .43 .37 .32 .41 .36 .32 .40 .35 .31 .39 .34 .31 .29

150 0.56 6 .39 .33 .28 .39 .32 .28 .37 .32 .28 .36 .31 .27 .35 .31 .27 .26

7 .36 .29 .25 .35 .29 .25 .34 .28 .24 .33 .28 .24 .32 .27 .24 .23

8 .32 .26 .22 .32 .26 .22 .31 .26 .22 .30 .25 .22 .29 .25 .22 .20

9 .30 .24 .20 .29 .24 .20 .29 .23 .20 .28 .23 .20 .27 .23 .20 .18

10 .28 .22 .18 .27 .22 .18 .27 .22 .18 .26 .21 .18 .25 .21 .18 .17

Angle cd/1000 lm Angle cd/1000 lm

<EGHL 1251/4 - DR> 0 155 50 145

5 164 55 150Lamp : MH250 (20500 lm)+

With Globe +

Reflector : FRP Dome +

Reflector

10 170 60 151

15 164 65 158

20 167 70 162

25 162 75 141

30 154 80 49.9

35 153 85 22.9

40 148 90 10.5

45 140

Coefficients of Utilization - Zonal Cavity

Multipliers%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

(For use with candlepower curves only)

%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Lamp

Watts

Conversion

Factor

Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance

0 .96 .96 .96 .94 .94 .94 .90 .90 .90 .86 .86 .86 .82 .82 .82 .81

1 .84 .80 .77 .82 .79 .76 .78 .76 .74 .75 .73 .71 .72 .71 .69 .67

250 1 2 .73 .67 .63 .71 .66 .62 .68 .64 .61 .66 .62 .59 .63 .60 .58 .56

3 .64 .57 .52 .62 .56 .51 .60 .55 .50 .58 .53 .49 .56 .52 .49 .47

175 0.68 4 .56 .49 .43 .55 .48 .43 .53 .47 .43 .51 .46 .42 .49 .45 .41 .40

5 .50 .43 .37 .49 .42 .37 .47 .41 .37 .46 .40 .36 .44 .40 .36 .34

6 .45 .38 .32 .44 .37 .32 .43 .37 .32 .41 .36 .32 .40 .35 .31 .30

7 .41 .34 .29 .40 .33 .29 .39 .33 .28 .38 .32 .28 .37 .32 .28 .26

8 .37 .30 .26 .37 .30 .26 .36 .30 .25 .35 .29 .25 .34 .29 .25 .24

9 .34 .28 .23 .34 .28 .23 .33 .27 .23 .32 .27 .23 .31 .26 .23 .21

10 .32 .25 .21 .31 .25 .21 .31 .25 .21 .30 .25 .21 .29 .24 .21 .19

Page 73: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

<EGNL 1401/4 - DR> 0 132 50 136

5 134 55 138Lamp : NH400 (46000 lm)+

With Globe +

Reflector : FRP Dome +

Reflector

10 148 60 142

15 155 65 144

20 153 70 115

25 145 75 80.3

30 137 80 43.9

35 130 85 16.7

40 127 90 8.1

45 131

Coefficients of Utilization - Zonal Cavity%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance

0 .81 .81 .81 .79 .79 .79 .75 .75 .75 .72 .72 .72 .69 .69 .69 .68

1 .71 .68 .66 .69 .67 .65 .66 .64 .62 .64 .62 .61 .61 .60 .59 .57

2 .62 .58 .54 .61 .57 .53 .59 .55 .52 .56 .53 .51 .54 .52 .50 .48

3 .55 .49 .45 .54 .49 .45 .52 .47 .44 .50 .46 .43 .48 .45 .42 .41

4 .49 .43 .38 .48 .42 .38 .46 .41 .38 .44 .40 .37 .43 .39 .37 .35

5 .43 .37 .33 .43 .37 .33 .41 .36 .33 .40 .36 .32 .39 .35 .32 .30

6 .39 .33 .29 .39 .33 .29 .37 .32 .29 .36 .32 .28 .35 .31 .28 .27

7 .36 .30 .26 .35 .30 .26 .34 .29 .25 .33 .29 .25 .32 .28 .25 .24

8 .33 .27 .23 .32 .27 .23 .31 .26 .23 .30 .26 .23 .30 .26 .23 .21

9 .30 .25 .21 .30 .24 .21 .29 .24 .21 .28 .24 .21 .27 .23 .20 .19

10 .28 .23 .19 .28 .22 .19 .27 .22 .19 .26 .22 .19 .26 .22 .19 .18

Angle cd/1000 lm Angle cd/1000 lm

<EGHL 1401/4 - DR> 0 133 50 102

5 132 55 122Lamp : MH400 (34000 lm)+

With Globe +

Reflector : FRP Dome +

Reflector

10 142 60 126

15 150 65 111

20 140 70 105

25 132 75 80.6

30 125 80 30.0

35 119 85 16.9

40 109 90 8.9

45 98.0

Coefficients of Utilization - Zonal Cavity%Effective Ceiling

Cavity Reflectance( cc)ρ80 70 50 30 10 0

%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance

0 .70 .70 .70 .69 .69 .69 .66 .66 .66 .63 .63 .63 .60 .60 .60 .59

1 .62 .59 .57 .60 .58 .56 .58 .56 .54 .55 .54 .53 .53 .52 .51 .50

2 .54 .50 .47 .53 .49 .46 .51 .48 .45 .49 .46 .44 .47 .45 .43 .42

3 .48 .43 .39 .47 .42 .39 .45 .41 .38 .43 .40 .37 .42 .39 .37 .36

4 .42 .37 .33 .42 .37 .33 .40 .36 .33 .39 .35 .32 .37 .34 .32 .31

5 .38 .33 .29 .37 .32 .29 .36 .32 .28 .35 .31 .28 .34 .30 .28 .27

6 .34 .29 .25 .34 .29 .25 .33 .28 .25 .32 .28 .25 .31 .27 .25 .23

7 .31 .26 .23 .31 .26 .23 .30 .25 .22 .29 .25 .22 .28 .25 .22 .21

8 .29 .24 .20 .28 .24 .20 .27 .23 .20 .27 .23 .20 .26 .23 .20 .19

9 .26 .22 .19 .26 .22 .18 .25 .21 .18 .25 .21 .18 .24 .21 .18 .17

10 .25 .20 .17 .24 .20 .17 .24 .20 .17 .23 .19 .17 .23 .19 .17 .16

Page 74: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Dimension

< EG Bracket Type > < EG Stanchion Type >

< EG Ceiling Type > < EG Pendant Type >

Page 75: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

H.I.D Lighting Fixtures Pole Type

Explosion proof & Vaportight

Weathertight

NEMA 3, 3R, 5

Lighting

FixturesConstruction Lamps

Lamp

Watt

Catalog Number

Hand Rail Type Pedestal Type

2.5M Height 3.5M Height 2.5M Height 3.5M Height

EAEx d IIC T4

Ex d IIB T4

High

Pressure

Sodium

150 EANLP20915-25H EANLP20915-35H EANLP20915-25P EANLP20915-35P

200 EANLP20920-25H EANLP20920-35H EANLP20920-25P EANLP20920-35P

250 EANLP20925-25H EANLP20925-35H EANLP20925-25P EANLP20925-35P

Mercury

Vapor

200 EAMLP20920-25H EAMLP20920-35H EAMLP20920-25P EAMLP20920-35P

250 EAMLP20925-25H EAMLP20925-35H EAMLP20925-25P EAMLP20925-35P

400 EAMLP20940-25H EAMLP20940-35H EAMLP20940-25P EAMLP20940-35P

Metal

Halide

175 EAHLP20917-25H EAHLP20917-35H EAHLP20917-25P EAHLP20917-35P

250 EAHLP20925-25H EAHLP20925-35H EAHLP20925-25P EAHLP20925-35P

400 EAHLP20940-25H EAHLP20940-35H EAHLP20940-25P EAHLP20940-35P

SR Ex nR II T3

High

Pressure

Sodium

50 SRNLP20905-25H SRNLP20905-35H SRNLP20905-25P SRNLP20905-35P

70 SRNLP20907-25H SRNLP20907-35H SRNLP20907-25P SRNLP20907-35P

100 SRNLP20910-25H SRNLP20910-35H SRNLP20910-25P SRNLP20910-35P

150 SRNLP20915-25H SRNLP20915-35H SRNLP20915-25P SRNLP20915-35P

20 SRNLP20920-25H SRNLP20920-35H SRNLP20920-25P SRNLP20920-35P

250 SRNLP20925-25H SRNLP20925-35H SRNLP20925-25P SRNLP20925-35P

Mercury

Vapor

100 SRMLP20910-25H SRMLP20910-35H SRMLP20910-25P SRMLP20910-35P

200 SRMLP20920-25H SRMLP20920-35H SRMLP20920-25P SRMLP20920-35P

250 SRMLP20925-25H SRMLP20925-35H SRMLP20925-25P SRMLP20925-35P

400 SRMLP20940-25H SRMLP20940-35H SRMLP20940-25P SRMLP20940-35P

Metal

Halide

100 SRHLP20910-25H SRHLP20910-35H SRHLP20910-25P SRHLP20910-35P

175 SRHLP20917-25H SRHLP20917-35H SRHLP20917-25P SRHLP20917-35P

250 SRHLP20925-25H SRHLP20925-35H SRHLP20925-25P SRHLP20925-35P

400 SRHLP20940-25H SRHLP20940-35H SRHLP20940-25P SRHLP20940-35P

VDY IP55

High

Pressure

Sodium

50 VDNLP20905-25H VDNLP20905-35H VDNLP20905-25P VDNLP20905-35P

70 VDNLP20907-25H VDNLP20907-35H VDNLP20907-25P VDNLP20907-35P

100 VDNLP20910-25H VDNLP20910-35H VDNLP20910-25P VDNLP20910-35P

150 VDNLP20915-25H VDNLP20915-35H VDNLP20915-25P VDNLP20915-35P

200 VDNLP20920-25H VDNLP20920-35H VDNLP20920-25P VDNLP20920-35P

250 VDNLP20925-25H VDNLP20925-35H VDNLP20925-25P VDNLP20925-35P

Mercury

Vapor

100 VDMLP20910-25H VDMLP20910-35H VDMLP20910-25P VDMLP20910-35P

200 VDMLP20920-25H VDMLP20920-35H VDMLP20920-25P VDMLP20920-35P

250 VDMLP20925-25H VDMLP20925-35H VDMLP20925-25P VDMLP20925-35P

400 VDMLP20940-25H VDMLP20940-35H VDMLP20940-25P VDMLP20940-35P

Metal

Halide

100 VDHLP20910-25H VDHLP20910-35H VDHLP20910-25P VDHLP20910-35P

175 VDHLP20917-25H VDHLP20917-35H VDHLP20917-25P VDHLP20917-35P

250 VDHLP20925-25H VDHLP20925-35H VDHLP20925-25P VDHLP20925-35P

400 VDHLP20940-25H VDHLP20940-35H VDHLP20940-25P VDHLP20940-35P

FeaturesThese pole type fittings are the combinations

of lighting units for EA, SR type Lighting

Fixtures, goose neck shaped poles and EC

type ballasts.

They are mainly used for tower illumination of

chemical plants where high illumination long life

service are required.

The construction of the ballast and the

mounting box are the same as those of

flameproof EA and non-sparking SR type

Lighting Fittings.

Page 76: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

H.I.D Lighting Fixtures with 7M Pole Type

Explosion proof & Vaportight

Weathertight

NEMA 3, 3R, 5

Lighting

FixturesConstruction Lamps

Lamp

Watt

Catalog Number

PHR PHY PHL

EAEx d IIC T4

Ex d IIB T4

High Pressure

Sodium

200 EANPHR920 EANPHY920 EANPHL920

250 EANPHR925 EANPHY925 EANPHL925

400 EAMPHR940 EAMPHY940 EAMPHL940

Mercury Vapor250 EAMPHR925 EAMPHY925 EAMPHL925

400 EAHPHR940 EAHPHY940 EAHPHL940

Metal Halide250 EAHPHR925 EAHPHR925 EAHPHL925

400 EAHPHR940 EAHPHR940 EAHPHR940

SR Ex nR II T3

High Pressure Sodium

200 SRNPHR920 SRNPHY920 SRNPHL920

250 SRNPHR925 SRNPHY925 SRNPHL925

400 SRMPHR940 SRMPHY940 SRMPHL940

Mercury Vapor250 SRMPHR925 SRMPHY925 SRMPHL925

400 SRHPHR940 SRHPHY940 SRHPHL940

Metal Halide250 SRHPHR925 SRHPHR925 SRHPHL925

400 SRHPHR940 SRHPHR940 SRHPHL940

Features

These lighting equipments are furnished with flameproof or non-sparking lighting fixtures on the top of poles the ballasts and the connection facilities for supply cables are provided in the lower part of the poles. The constructions of lighting units are almost the same as those of EA, SR type Lighting Fixtures.The poles supplied in three different shapes of heads, such as Types PHR, PHY and PHL.Each of them is classified in three kinds according to the types of protection of ballast housings, and in each one of the ballast housings is installed a flameproof or increase-safety ballasts. Standard poles are Anchor base type pedestal type poles, Embedded type or others are supplied to special order.

<PHR> <PHL>

If you need more information, contact us please. ⇨

Page 77: Nb cat

HID Ballast

Copyright by NAMBUK Electric Co., LTD. 2004

Flameproof HID Ballast

Exterior Series

< SB Type >< UB Type >

Application Standard Materials

In consideration of various environmental conditions

in hazardous areas, MB Mercury ballast and NB

Sodium ballasts and HB Metal Halide ballasts are

designed for maintaining much safety of strength and

weatherproofness of enclosure and low

temperature-rise of windings.

These ballasts are the same types as those attached

to flameproof type lighting fixtures, as EA, EU, EXFD

(flood lighting), increase safety type lighting fixtures,

as SR, SGFD(flood lighting), and Vaportight type

lighting Fixtures, as VDY, VS the special design

features, such as electrical characteristics and wiring

diagrams described on next page, are applicable to

the ballasts of above fitting.

SB Body : Steel

UB Body : Cast aluminium alloy

End Cover : Die Casting aluminium

Mounting box : Cast aluminium alloy

Attention

Supply voltages shall be as close as rated voltage :

In general, allowable fluctuation of supply voltages

are ±5% for choke type ballasts, and ±10% for

constant wattage type ballasts.

Wattages and frequencies other than rating must be

avoided.:

Especially, the use of smaller lamp and the use of

60Hz ballast on 50Hz circuit give much danger in

explosion protection.

Allowable ambient temperature for standard units it

from -20 to 55 :℃ ℃

When the mercury and Sodium Lamp ballasts are

used in lower or higher temperature, special

considerations are necessary Further information will

be given on request.

Features

The SB body is made of thick wall steel pipe, it is

extremely strong against the pressure of internal and

external impact.

UB type is unite ballast body with mounting box.

The capacitor is attached not embedded in the

compound so as to eliminate the influence of heat

of windings.

Ordering Information

S M B 1 1 0 ① ② ③ ④

S : Standard Type Ballast① Ballast Type② Voltage (V)③ Wattage (W)④

U : Unite Type Ballast NB - High Pressure Sodium 1 - 110 05 : 50

HB - Metal Halide 2 - 220 07 : 70

MB - Mercury Vapor 3 - 240 10 : 100

4 - 460 15 : 150

17 : 175

20 : 200

25 : 250

40 : 400

Page 78: Nb cat

HID Ballast

Copyright by NAMBUK Electric Co., LTD. 2004

Electrical Data

BallastWatts

(W)

Input

Volts

(V)

Input

Current

(A)

Input

Watts

(W)

Short

Circuit

Current (A)

Secondary

Volts

(V)

Secondary

Current

(A)

Metal

Halide

100 220 0.55 110 1.6 250 1.0

175 220 1.05 210 1.6 300 1.5

250 220 1.4 280 2.5 300 2.1

400 220 2.2 460 3.8 300 3.25

High

Pressure

Sodium

50 220 0.29 57.5 0.9 220 0.76

70 220 0.4 80 1.2 220 1.0

100 220 0.55 110 1.6 220 1.2

150 220 0.8 160 2.3 220 1.8

200 220 1.1 220 3.0 220 2.3

250 220 1.38 275 3.75 220 3.0

400 220 2.2 436 6.0 220 4.6

Mercury

Vapour

200 220 1.0 205 3.0 220 1.7

400 220 2.15 430 5.7 220 3.25

Dimensions (mm)

Page 79: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Accessary & Component

Globe Guard

GL 13 GL 21GD 13

GD 25

GL 20 GL 23GD 22

GD 27

GL 20MGD 22M

Cat. No Lamp Watts Fixture Series Material Cat. No Lamp Watts Fixture

Series Material

GL 13 50 - 100 VG Heat impact resistant GD 13 50 - 100 VG Al die casting

GL 20 150 - 250 VN, EVN Heat impact resistant GD 22 150 - 250 VN, EVN Stainless Steel

GL 20M 250 - 400 VZ Heat impact resistant GD 22M 250 - 400 VZ Stainless Steel

GL 21 50 - 100 EGS Heat impact resistant GD 25 50 - 100 EGS Al die casting

GL 23 150 - 400 EG Heat impact resistant GD 27 150 - 400 EG Al die casting

Page 80: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Reflector

DR 32DR 43

DR 44

DR 43F

AR 32 AR 43AR 43F

Cat. No Lamp Watts Fixture Series Material

DR 32 50 - 100 EGS, VG Aluminium

DR 43 150 - 400 EG, VN, EVN, VZ Aluminium

DR 44 400 EGFD Aluminium

AR 32 50 - 100 EGS, VG Aluminium

DR 43F 150 - 250 EG, VN, EVN, VZ FRP

AR 43F 150 -250 EG, VN, EVN, VZ FRP

Page 81: Nb cat

SECTION - 3L

Fluorescent Lighting Fixture

Page 82: Nb cat

SECTION 3L

Fluorescent Lighting Fixtures INDEX

Model

Lamp Type / Watt. Certification for Explosion-proof

PAGE

Fluorescent IEC

18 20 26 32 36

VDFL(S)1

2

1

2

1

2

1

2

1

2Weatherproof Type 3L - 1

VEFL1

2

1

2

1

2

1

2

1

2

Ex de IIC T4 IP66

Ex eds IIC T43L - 3

SYFL1

2

1

2

1

2

1

2

1

2Ex nR II T6 3L - 5

SGFL

1

2

3

4

5

1

2

3

4

5

1

2

3

4

5

1

2

3

4

5

1

2

3

4

5

Ex nR II T6 3L - 8

EXFL1

2

1

2

1

2

1

2

1

2

Ex d IIB T6

Ex d IIC T63L - 10

Page 83: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Fluorescent Vaportight Lighting Fixtures

VDFL(S) Series

Weatherproof Type

NEMA 4, 4X, 7

<VDFL(S) 18W>

<VDFL(S) 36W>

Application Features

VDFL(S) Series Fluorescent lighting fixtures are used ;

in installations where moisture, dirt, dust,

vibration, corrosion and rough usage are

problems.

Simple construction of enclosures.

Safety operation and ease of maintenance.

With the electronic ballast or Inductive ballast to be high

power factor, and integral emergency light.

With folding protective bowl of polycarbonate without

wire guard for the most efficient light distribution.

To open cover, insert tool (8mm Hex Wrench or 13mm

Socket Wrench) in key hole and turn right or left 90° as

below figure.

For single- and two-pin fluorescent lamps

All-pole disconnection via N/C switch when opening

cover or battery enclosure.

Maintained emergency operation 1.5h or 3h

Standard Materials

Body : Glass fiber polyester

Globe : Polycarbonate

Inner Reflector : High purity aluminium

Compliance

IP66

Standard Finish

Natural

If you want another color, contact us please.

Technical Data WeightElectrical Rating Catalog No. Weight

Rated Voltage AC110V/ 220V/ 240V VDFL(S) 31212 5 Kg

Rated Wattage18W/ 18W×2/ 20W/ 20W×2/

32W/ 32W×2/ 36W/ 36W×2/ VDFL(S) 31252 8 Kg

If you need more information, ⇨

contact us please

Battery 7Ah NiCd-Battery

Emergency light operation time 1.5h 3h

Emergency light power18W 90% 45%

36W 45% 25%

Entry Size 1/2", 3/4", 1"

Page 84: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number Ordering Information

Lamp Watt(W) Voltage(V)Catalog

Number

V D F L (S ) 3 1 1 4 1 ① ② ③ ④ ⑤ ⑥

Fluorescent

Lamp

18W×1110 VDFL(S) 31111 Lighting Fixture Type ①

220 VDFL(S) 31211 VDFL(S) Fluorescent Lighting Fixture

18W×2110 VDFL(S) 31112 Ballast Type② Lamp Wattage (W)⑤

220 VDFL(S) 31212 3 - Internal Ballast 1 - 18

32W×1110 VDFL(S) 31131 4 - Emergency Type 2 - 20

220 VDFL(S) 31231 Mounting Type③ 3 - 32

32W×2110 VDFL(S) 31132 4 - 40

220 VDFL(S) 31232 Voltage (V)④ 5 - 36

36W×1110 VDFL(S) 31151 1 - 110

220 VDFL(S) 31251 2 - 220 Quantity of ⑥ Lamp

36W×2110 VDFL(S) 31152 3 - 230 1 - ×1

220 VDFL(S) 31252 4 - 240 2 - ×2

Photometric Data

<VDFL(S) 31252> 0 -180 (Blue)˚ ˚ 90 -270 (Red)˚ ˚

Angle cd/1000 lm Angle cd/1000 lmLamp : FL36×2+

(2×2500 lm)

With globe and guard+

0 169 0 169

10 158 10 169

20 158 20 156

30 146 30 145

40 124 40 145

50 101 50 133

right picture explanation☞

Blue : Normal to Lamp+

Red : Parallel to Lamp+

60 79 60 120

70 56 70 109

80 23 80 85

90 5 90 60

Dimension

<VDFL(S)>

Page 85: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Fluorescent Lighting Fixtures

VEFL Series

Wet Locations

NEMA 4, 4X, 7

Type of Explosion-proof

Flameproof-Increase Safety (Ex ed IIC T4 IP66)

Flameproof-Increase Safety-Special (Ex eds IIC T4 IP66)

<VEFL 18W>

Page 86: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Fluorescent Lighting Fixtures

VEFL Series

Wet Locations

NEMA 4, 4X, 7

Type of Explosion-proof

Flameproof-Increase Safety (Ex ed IIC T4 IP66)

Flameproof-Increase Safety-Special (Ex eds IIC T4 IP66)

<VEFL 18W>

<VEFL 36W>

Application Features

VEFL Series Fluorescent lighting fixtures are used ;

were ignitable concentrations of flammable gases,

vapors or liquids can exist all of the time or

some of the time under normal operation

conditions.

in installations where moisture, dirt, dust,

vibration, corrosion and rough usage are

problems.

Simple construction of enclosures.

Safety operation and ease of maintenance.

With the electronic ballast or Inductive ballast to be

high power factor, and integral emergency light.

With folding protective bowl of polycarbonate without

wire guard for the most efficient light distribution.

To open cover, insert tool (8mm Hex Wrench or 13mm

Socket Wrench) in key hole and turn right or left 90° as

below figure.

For single- and two-pin fluorescent lamps

All-pole disconnection via N/C switch when opening

cover or battery enclosure.

Maintained emergency operation 1.5h or 3h

Standard Materials Body : Glass fiber polyester

Globe : Polycarbonate

Inner Reflector : Engineering Plastic

Compliance

IEC 60079-0, 1. 7

Certification Certified by KOSHA (Korea Occupational Safety &

Health Agency), KGS (Korea Gas Safety

Corporation), and the others.

Standard Finish Natural

If you want another color, contact us please.

Technical Data WeightElectrical Rating Catalog No. Weight

Rated Voltage AC110V/ 220V/ 240V VEFL 31212 5 Kg

Rated Wattage18W/ 18W×2/ 20W/ 20W×2/

32W/ 32W×2/ 36W/ 36W×2/ VEFL 31252 8 Kg

⇨ If you need more

information, contact us please

Battery 7Ah NiCd-Battery

Emergency light operation time 1.5h 3h

Emergency light power18W 90% 45%

36W 45% 25%

Entry Size 1/2", 3/4", 1"

Page 87: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number Ordering Information

Lamp Watt(W) Voltage(V)Catalog

Number V E F L 3 1 1 4 1 ① ② ③ ④ ⑤ ⑥

Fluorescent

Lamp

18W×1110 VEFL 31111 ① VEFL Lighting Fixture ② Ballast Type

220 VEFL 31211 ③ Mounting Type 3 - General Type

18W×2110 VEFL 31112 1 - Pendant 4 - Emergency Type

220 VEFL 31212 2 - Ceiling

32W×1110 VEFL 31131 3 - Wall Bracket ④ Voltage (V)

220 VEFL 31231 4 - Hexagonal Screw 1 - 110

32W×2110 VEFL 31132 5 - Eye Bolt 2 - 220

220 VEFL 31232 6 - Pipe Clamp 3 - 230

36W×1110 VEFL 31151 ⑤ Lamp Wattage (W) 4 - 240

220 VEFL 31251 1 - 18

36W×2110 VEFL 31152 2 - 20 ⑥ Quantity of Lamp

220 VEFL 31252 3 - 32 1 - ×1

Photometric Data 4 - 40 2 - ×2

5 - 36

<VEFL 31252> 0˚-180˚(Blue) 90˚-270˚(Red)

Angle cd/1000 lm Angle cd/1000 lm+Lamp : FL36×2

(2×2500 lm)

+With globe and guard

0 169 0 169

10 158 10 169

20 158 20 156

30 146 30 145

40 124 40 145

50 101 50 133

☞right picture explanation

+Blue : Normal to Lamp

+Red : Parallel to Lamp

60 79 60 120

70 56 70 109

80 23 80 85

90 5 90 60

Dimension

<VEFL>

Page 88: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Fluorescent (Emergency) Lighting Fixtures

SYFL Series

Wet Locations

NEMA 3, 3R, 7

Type of Explosion-proof

Non - Sparking (Ex nR II T6)

Application Features

SYFL Series fluorescent lighting fixtures are used ;

in heavy process industries having environments

where flammable or explosive vapors or gases are

present.

in hazardous areas, both indoors and outdoors

where long life and low maintenance costs are

desired.

in petroleum refineries, chemical, petrochemical

and other heavy process industry facilities.

were ignitable concentrations of flammable gases,

vapors or liquids can exist all of the time or some

of the time under normal operation conditions.

in installations where moisture, dirt, dust, vibration,

corrosion and rough usage are problems.

The lighting unit consists of the main body and the

reflector, both made of pressed sheet steel, and one

or two lamp cover assemblies.

The lamp cover is sealed at each and into the

lampholder casing by synthetic rubber packing, and an

access cover to the relamping lampholder is provided

so as to restrict breathing. The cover for replacement

of lamp at the end of one lampholder casing.

The ballast is made in compliance with the increased

safety requirements, and is mounted to the reverse

side of the main body.

The guard is designed to be able to open at either

side by releasing two fixing screws. This allows easy

cleaning of the lamp cover.

<SYFL 31152>

Standard Materials Certification Standard Finish Enclosure : Sheet steel

Lamp cover :

Heat resistant hard tubing glass

Guard : Stainless steel

Reflector : Sheet steel

(Stove enamelled white inside)

Suspension stem :

Heavy gauge steel pipe

Certified by KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas Safety

Corporation), and the others.

MUNSELL No. 7.5BG 6/1.5

If you want another color,

contact us please.

Compliance Weight

IEC 60079-0, 1, 7

NEMA 3, 3R, 7

Catalog No. Weight

SYFL 31152 11.8 ㎏

Technical Data Emergency

Electrical Rating Battery Rating

Rated Voltage AC110V/ 220V/ 240VDC 9.6V 1.2Ah

Rated Wattage 18W/ 18W×2/ 20W/ 20W×2/

32W/ 32W×2/ 36W/ 36W×2/ Operating Time

Rated Frequency 50Hz/ 60Hz30min or 1hr

Entry Size 1/2", 3/4", 1"

Relamping

Lamp housing is sloped as

shown for ease of relamping (no

space needed between fixtures

for relamping)

If you need more information, contact us please. ⇨

Page 89: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number

Type Watt Voltage(V) Pendant Ceiling 90° Bracket 40° Bracket Certification

Fluorescent

Lighting

Fixture

18W×1110 SYFL 31121 SYFL 32121 SYFL 33121 SYFL 34121

Ex nR II T6

220 SYFL 31221 SYFL 32221 SYFL 33221 SYFL 34221

18W×2110 SYFL 31122 SYFL 32122 SYFL 33122 SYFL 34122

220 SYFL 31222 SYFL 32222 SYFL 33222 SYFL 34222

20W×1110 SYFL 31121 SYFL 32121 SYFL 33121 SYFL 34121

220 SYFL 31221 SYFL 32221 SYFL 33221 SYFL 34221

20W×2110 SYFL 31122 SYFL 32122 SYFL 33122 SYFL 34122

220 SYFL 31222 SYFL 32222 SYFL 33222 SYFL 34222

32W×1110 SYFL 31131 SYFL 32131 SYFL 33131 SYFL 34131

220 SYFL 31231 SYFL 32231 SYFL 33231 SYFL 34231

32W×2110 SYFL 31132 SYFL 32132 SYFL 33132 SYFL 34132

220 SYFL 31232 SYFL 32232 SYFL 33232 SYFL 34232

36W×1110 SYFL 31151 SYFL 32151 SYFL 33151 SYFL 34151

220 SYFL 31251 SYFL 32251 SYFL 33251 SYFL 34251

36W×2110 SYFL 31152 SYFL 32152 SYFL 33152 SYFL 34152

220 SYFL 31252 SYFL 32252 SYFL 33252 SYFL 34252

Emergency

Fluorescent

Lighting

Fixture

18W×1110 SYEFL 31121 SYEFL 32121 SYEFL 33121 SYEFL 34121

220 SYEFL 31221 SYEFL 32221 SYEFL 33221 SYEFL 34221

18W×2110 SYEFL 31122 SYEFL 32122 SYEFL 33122 SYEFL 34122

220 SYEFL 31222 SYEFL 32222 SYEFL 33222 SYEFL 34222

20W×1110 SYEFL 31121 SYEFL 32121 SYEFL 33121 SYEFL 34121

220 SYEFL 31221 SYEFL 32221 SYEFL 33221 SYEFL 34221

20W×2110 SYEFL 31122 SYEFL 32122 SYEFL 33122 SYEFL 34122

220 SYEFL 31222 SYEFL 32222 SYEFL 33222 SYEFL 34222

32W×1110 SYEFL 31131 SYEFL 32131 SYEFL 33131 SYEFL 34131

220 SYEFL 31231 SYEFL 32231 SYEFL 33231 SYEFL 34231

32W×2110 SYEFL 31132 SYEFL 32132 SYEFL 33132 SYEFL 34132

220 SYEFL 31232 SYEFL 32232 SYEFL 33232 SYEFL 34232

36W×1110 SYEFL 31151 SYEFL 32151 SYEFL 33151 SYEFL 34151

220 SYEFL 31251 SYEFL 32251 SYEFL 33251 SYEFL 34251

36W×2110 SYEFL 31152 SYEFL 32152 SYEFL 33152 SYEFL 34152

220 SYEFL 31252 SYEFL 32252 SYEFL 33252 SYEFL 34252

Ordering Information

S Y F L 3 1 1 2 1 ① ② ③ ④ ⑤ ⑥

Lighting Fixture Type① Ballast Type② Mounting Type③

SYFL - Increase Safety Fluorescent Lighting Fixture 3 - Internal Ballast 1 - Pendant

SYEFL - Emergency Fluorescent Lighting Fixture 2 - Ceiling

3 - 90° Bracket

Voltage (V)④ Lamp Wattage (W)⑤ Quantity of ⑥ Lamp 4 - 40° Bracket

1 - 110 1 - 18 1 - ×1

2 - 220 2 - 20 2 - ×2

3 - 230 3 - 32

4 - 240 4 - 40

5 - 36

Photometric Data

Anglecd/1000 lm

Anglecd/1000 lm

Blue Red Blue Red<SYFL 32152>0 201.3 201.3 50 160.0 116.3

Lamp : FL36×2+

(2×2500 lm)

With Globe and Guard+

5 201.3 195.0 55 146.3 101.3

10 201.3 192.5 60 135.0 83.8

15 200.0 188.8 65 128.8 65.0

20 191.3 182.5 70 123.8 47.5

25 185.0 175.0 75 110.0 30.0

30 180.0 166.3 80 82.5 16.3right picture explanation☞

Blue : Normal to Lamp+

Red : Parallel to Lamp+

35 175.0 156.3 85 68.8 7.5

40 170.0 143.8 90 50.0 2.5

45 165.0 131.3

Page 90: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

< SYFL > < Pendant Type >

< 40° Bracket Type > < 90° Bracket Type > < Ceiling Type >

< SYEFL Series > < Pendant Type >

< 40° Bracket Type > < 90° Bracket Type > < Ceiling Type >

Page 91: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Fluorescent (Emergency) Lighting Fixtures

SGFL Series

Recessed Type

Booth Type

Type of Explosion-proof

Non - Sparking (Ex nR II T6)

Application Features

SGFL Series fluorescent lighting fixtures are used ;

in heavy process industries having environments

where flammable or explosive vapors or gases are

present.

in hazardous areas, both indoors and outdoors

where long life and low maintenance costs are

desired.

in petroleum refineries, chemical, petrochemical

and other heavy process industry facilities.

where ignitable concentrations of flammable gases,

vapors or liquids can exist all of the time or some

of the time under normal operation conditions.

in installations where moisture, dirt, dust, vibration,

corrosion and rough usage are problems.

The lighting fixture consist of the main body and the

inside reflector, both made of pressed sheet steel, and

1-5 lamp cover assemblies.

The lamp cover is sealed at each end into the

lampholder casing by synthetic rubber packing, and an

access cover to the relamping lampholder is provided

so as to restrict breathing.

The guard is designed to be able to open at either

side by releasing 4 fixing screws to down guard by

two hinges.

<SGFL 86252>

Standard Materials Certification Compliance

Enclosure : Sheet steel

Lamp cover : Heat resistant hard

tubing glass

Guard : Stainless steel

Reflector : Sheet steel (Stove

enamelled white inside)

Lamp holder casing : Urea resin

Certified by KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas Safety

Corporation), and the others.

IEC 60079-0, 15

NEMA 3, 3R, 7

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color,

contact us please.

Technical Data Emergency

Electrical Rating Battery Rating

Rated Voltage AC110V/ 220V/ 240VDC 9.6V 1.2Ah

Rated Wattage 32W/ 36W/

×1/ ×2/ ×3/ ×4/ ×5 Operating Time

Rated Frequency 50Hz/ 60Hz30min or 1hr

Entry Size 1/2", 3/4", 1"

WeightCatalog No. Weight

SGFL 86252 37 ㎏

If you need more information, contact us please. ⇨

Page 92: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number

Lamp Type Watt Voltage Catalog No. Certification

<SGFL 86>

<SGFL 87>

Fluorescent

Lamp

Recessed

Type

20W×1110 SGFL 86121

Ex nR II T6

220 SGFL 86221

20W×2110 SGFL 86122

220 SGFL 86222

36W×1110 SGFL 86151

220 SGFL 86251

36W×2110 SGFL 86152

220 SGFL 86252

36W×3110 SGFL 86153

220 SGFL 86253

36W×4110 SGFL 86154

220 SGFL 86254

Booth

Type

36W×1110 SGFL 87151

220 SGFL 87251

36W×2110 SGFL 87152

220 SGFL 87252

36W×3110 SGFL 87153

220 SGFL 87253

36W×4110 SGFL 87154

220 SGFL 87254

36W×5110 SGFL 87155

220 SGFL 87255

Emergency

Type

36W×1110 SGEFL 87151

220 SGEFL 87251

36W×2110 SGEFL 87152

220 SGEFL 87252

36W×3110 SGEFL 87153

220 SGEFL 87253

36W×4110 SGEFL 87154

220 SGEFL 87254

36W×5110 SGEFL 87155

220 SGEFL 87255

Ordering Information S G F L 3 1 1 4 1 ① ② ③ ④ ⑤ ⑥

Lighting Fixture Type① ② Model Type

SGFL - Fluorescent Lighting 86 - Recessed Type

SGEFL - Emergency Type 87 - Booth Type

Voltage (V)③ ④ Lamp Wattage (W) ⑤ Quantity of Lamp

1 - 110 1 - 18 1 - ×1

2 - 220 2 - 20 2 - ×2

3 - 230 3 - 32 3 - ×3

4 - 240 4 - 40 4 - ×4

5 - 36 5 - ×5

Photometric Data0 -180 (Blue)˚ ˚ 90 -270 (Red)˚ ˚

Angle cd/1000 lm Angle cd/1000 lm

0 183 0 183<SGFL 86232>10 183 10 183

Lamp : FL32×2(6000 lm)+

With globe and guard+20 169 20 169

30 155 30 155

40 141 40 127

50 127 50 84

60 84 60 56right picture explanation☞

Blue : Normal to Lamp+

Red : Parallel to Lamp+

70 42 70 14

80 14 80 0

90 0 90 0

Page 93: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Fluorescent (Emergency) Lighting Fixtures

EXFL Series

Wet Locations

NEMA 3, 3R, 4, 4X, 7

Type of Explosion-proof

Flameproof (Ex d IIB T6 IP66)

Flameproof (Ex d IIC T6 IP66)

Application Features EXFL Series Fluorescent lighting fixtures are used ;

in heavy process industries having environments

where flammable or explosive vapors or gases are

present.

in hazardous areas, both indoors and outdoors

where long life and low maintenance costs are

desired.

in petroleum refineries, chemical, petrochemical

and other heavy process industry facilities.

where ignitable concentrations of flammable gases,

vapors or liquids can exist all of the time or some

of the time under normal operation conditions.

in installations where moisture, dirt, dust, vibration,

corrosion and rough usage are problems.

The flameproof enclosures of lamp and ballast are

separated from each other with barrier walls and

sealing glands.

The lamp housing has a tubular lamp cover cemented

into the lampholder casings at the both ends. One

casing contains a fixed lampholder and the other a

relamping lampholder.

The sloping device is provided at the mounting base of

relamping side. The lamp housing can be sloped by

releasing two fixing screws for easier replacement of

the lamp.

The guard is designed to be able to open at either

side by releasing two fixing screws. It is convenient to

clean the lamp cover.

<EXFL 21252>

Standard Materials Certification Standard Finish Enclosure : Cast aluminium alloy

Lamp cover :

Heat resistant hard tubing glass

Guard : Steel

Reflector : Sheet steel

(Stove enamelled white inside)

Suspension stem :

Heavy gauge steel pipe

Certified by KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas Safety

Corporation), and the others.

MUNSELL No. 7.5BG 6/1.5

If you want another color,

contact us please.

Compliance Weight

IEC 60079-0, 1

NEMA 3, 3R, 4, 4X, 7

Catalog No. Weight

EXFL 21252 11.4㎏

Technical Data Emergency

Electrical Rating Battery Rating

Rated Voltage AC110V/ 220V/ 240VDC 9.6V 1.2Ah

Rated Wattage 18W/ 18W×2/ 20W/ 20W×2/

32W/ 32W×2/ 36W/ 36W×2/ Operating Time

Rated Frequency 50Hz/ 60Hz30min or 1hr

Entry Size 1/2", 3/4", 1"

Relamping

Lamp housing is sloped as

shown for ease of relamping (no

space needed between fixtures

for relamping)

If you need more information, contact us please. ⇨

Page 94: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number

Lamp Watt Volt Pendant Ceiling 90° Bracket 40° Bracket Certification

Fluorescent

Lamp

18W×1110 EXFL 21111 EXFL 22111 EXFL 23111 EXFL 24111

Ex d IIB T6 IP66220 EXFL 21211 EXFL 22211 EXFL 23211 EXFL 24211

18W×2110 EXFL 21112 EXFL 22112 EXFL 23112 EXFL 24112

220 EXFL 21212 EXFL 22212 EXFL 23212 EXFL 24212

18W×1110 EXFL 21111-H EXFL 22111-H EXFL 23111-H EXFL 24111-H

Ex d IIC T6220 EXFL 21211-H EXFL 22211-H EXFL 23211-H EXFL 24211-H

18W×2110 EXFL 21112-H EXFL 22112-H EXFL 23112-H EXFL 24112-H

220 EXFL 21212-H EXFL 22212-H EXFL 23212-H EXFL 24212-H

32W×1110 EXFL 21131 EXFL 22131 EXFL 23131 EXFL 24131

Ex d IIB T6220 EXFL 21231 EXFL 22231 EXFL 23231 EXFL 24231

32W×2110 EXFL 21132 EXFL 22132 EXFL 23132 EXFL 24132

220 EXFL 21232 EXFL 22232 EXFL 23232 EXFL 24232

32W×1110 EXFL 21131-H EXFL 22131-H EXFL 23131-H EXFL 24131-H

Ex d IIC T6220 EXFL 21231-H EXFL 22231-H EXFL 23231-H EXFL 24231-H

32W×2110 EXFL 21132-H EXFL 22132-H EXFL 23132-H EXFL 24132-H

220 EXFL 21232-H EXFL 22232-H EXFL 23232-H EXFL 24232-H

Emergency

Fluorescent

Lamp

18W×1110 EXEFL 21111 EXEFL 22111 EXEFL 23111 EXEFL 24111

Ex d IIB T6 IP66220 EXEFL 21211 EXEFL 22211 EXEFL 23211 EXEFL 24211

18W×2110 EXEFL 21112 EXEFL 22112 EXEFL 23112 EXEFL 24112

220 EXEFL 21212 EXEFL 22212 EXEFL 23212 EXEFL 24212

18W×1110 EXEFL 21111-H EXEFL 22111-H EXEFL 23111-H EXEFL 24111-H

Ex d IIC T6220 EXEFL 21211-H EXEFL 22211-H EXEFL 23211-H EXEFL 24211-H

18W×2110 EXEFL 21112-H EXEFL 22112-H EXEFL 23112-H EXEFL 24112-H

220 EXEFL 21212-H EXEFL 22212-H EXEFL 23212-H EXEFL 24212-H

32W×1110 EXEFL 21131 EXEFL 22131 EXEFL 23131 EXEFL 24131

Ex d IIB T6220 EXEFL 21231 EXEFL 22231 EXEFL 23231 EXEFL 24231

32W×2110 EXEFL 21132 EXEFL 22132 EXEFL 23132 EXEFL 24132

220 EXEFL 21232 EXEFL 22232 EXEFL 23232 EXEFL 24232

32W×1110 EXEFL 21131-H EXEFL 22131-H EXEFL 23131-H EXEFL 24131-H

Ex d IIC T6220 EXEFL 21231-H EXEFL 22231-H EXEFL 23231-H EXEFL 24231-H

32W×2110 EXEFL 21132-H EXEFL 22132-H EXEFL 23132-H EXEFL 24132-H

220 EXEFL 21232-H EXEFL 22232-H EXEFL 23232-H EXEFL 24232-H

Ordering Information

E X F L 2 1 1 2 3 - H ① ② ③ ④ ⑤ ⑥ ⑦

Lighting Fixture Type① Ballast Type② Mounting Type③

EXFL - Flameproof Fluorescent Lighting Fixture 2 - Internal Ballast 1 - Pendant

EXEFL - Emergency Fluorescent Lighting Fixture 2 - Ceiling

3 - 90° Bracket

4 - 40° Bracket

Voltage (V)④ Lamp Wattage (W)⑤ Quantity of ⑥ Lamp Option⑦

1 - 110 1 - 18 1 - ×1 None : IIB Type

2 - 220 2 - 20 2 - ×2 - H : IIC Type

3 - 230 3 - 32

4 - 240 4 - 40

5 - 36

Page 95: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Photometric Data

Anglecd/1000 lm

Anglecd/1000 lm

Blue Red Blue Red<EXFL 22152> 0 201.3 201.3 50 160.0 116.3

5 201.3 195.0 55 146.3 101.3Lamp : FL36×2+

(2×2500 lm)

With Globe and Guard+

10 201.3 192.5 60 135.0 83.8

15 200.0 188.8 65 128.8 65.0

20 191.3 182.5 70 123.8 47.5

25 185.0 175.0 75 110.0 30.0

30 180.0 166.3 80 82.5 16.3right picture explanation☞

Blue : Normal to Lamp+

Red : Parallel to Lamp+

35 175.0 156.3 85 68.8 7.5

40 170.0 143.8 90 50.0 2.5

45 165.0 131.3

Dimension

< EXEFL > < Pendant Type >

< 40° Bracket Type > < 90° Bracket Type > < Ceiling Type >

< EXFL > < Pendant Type >

< 40° Bracket Type > < 90° Bracket Type > < Ceiling Type >

Page 96: Nb cat

SECTION - 4L

Flood Lighting Fixture

Page 97: Nb cat

SECTION 4L

Flood Lighting Fixtures INDEX

Model

Lamp Type / Watt.Certification for

Explosion-proof

PAGEHigh Pressure Sodium Metal Halide Mercury

IEC

150 200 250 400 175 250 400 200 250 400

SGFD ● ● ● ● ● ● ● ● ● ● Ex nR II T3 4L - 1

EXFD ● ● ● ● ● ● ● ● ● ● Ex d B T3Ⅱ 4L - 3

VQFD ● ● ● ● ● ● ● ● ● ● Ex nR T3 IP66Ⅱ 4L - 5

EGFD ● ● ● ● ● ● ● ● ● ● Ex d C T4Ⅱ 4L - 7·

Page 98: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Flood Lighting Fixtures

SGFD Series

Wet Locations

NEMA 3, 3R, 4, 4X, 7

Type of Explosion-proof

Non Sparking (Ex nR II T3)

Application Features Standard Materials

SGFD Series flood lighting fixtures

are used ;

in hazardous areas, both indoors

and outdoors where long life and

low maintenance costs are

desired.

in marine applications where

water spray and corrosive.

atmospheres are considerations

in petroleum refineries, chemical,

petrochemical and other heavy

process industry facilities.

in heavy process industries

having environments where

flammable or explosive vapors or

gases, or where combustible

dusts are present.

The body and mounting box are

wired with flameproof SPFC

flexible coupling.

The body is one piece casting

and the front flame incorporated

with front glass and guard is

hinged and fixed to the front of

the body.

The ballast is high quality one

maintaining much safety on

strength of enclosure.

The mounting box has a turning

base plate on the top and a

large access cover for wiring on

the side.

Main Body & Reflector:

Aluminum sheet

Front Frame :

Cast aluminium alloy

Front Glass :

Tempered plate glass

Ballast Housing : Steel

Wiring Tube :

SPFC Flexible coupling

Cradle : Steel

Mounting Box : Cast aluminium

alloy

<SGFD>

Certification

Certified by KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas Safety

Corporation), and the others.

Compliance

IEC 60079-0, 15

NEMA 3, 3R, 4, 4X, 7

IP55

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color,

contact us please.

Projection Angle Adjustment Technical Data

Vertical 60° up down Electrical RatingsHorizontal 60° right and left

Rated VoltageAC110V/ 220V/ 240V

( See Below)※

Rated Wattage 150W/ 175W/ 200W/ 250W/ 400W

Rated Frequency 50Hz/ 60Hz WeightEntry Sizes 1/2", 3/4", 1"

Catalog No. WeightAlso you can order various voltage : ※

120V/ 208V/ 277V/ 460VSGNFD 66040 31.5 Kg

If you need more information, contact us please. ⇨

Page 99: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number Ordering Information

Lamp Watt Ordering No. Certification S G N F D 6 6 0 1 5 ① ② ③

High

Pressure

Sodium

150 SGNFD 66015

Ex nR II T3

SGFD Flood Lighting Fixture① 200 SGNFD 66020

- SGMFD - Mercury Vapour

250 SGNFD 66025 - SGNFD - High Pressure Sodium

- SGHFD - Metal Halide400 SGNFD 66040

Metal

Halide

175 SGHFD 67017 : ② Lamp Type : Lamp Wattage (W)③

650 - Mercury Vapour 15 - 150250 SGHFD 67025 660 - H.P. Sodium 17 - 175

400 SGHFD 67040 670 - Metal Halide 20 - 200

Mercury

Vapor

200 SGMFD 65020 25 - 250

40 - 400250 SGMFD 65025

400 SGMFD 65040

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

<SGNFD 66025> 0 355.0 50 45.0

5 180.0 55 30.0Lamp : High pressure sodium +

250W

Bare lamp Lumen : 25000 lm+

Reflector : aluminum reflector+

10 142.5 60 20.0

15 135.0 65 12.5

20 135.0 70 7.5

25 132.5 75 2.5

30 122.5 80 0.0

35 120.0 85 0.0

40 107.5 90 0.0

45 75.0

Dimension

< SGFD >

Page 100: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Flood Lighting Fixtures

EXFD Series

Wet Locations

NEMA 3, 3R, 4, 4X, 7

Type of Explosion-proof

<EXFD>

Flameproof (Ex d IIB T3)

Application

EXFD Series flood lighting fixtures are used ;

in hazardous areas, both indoors and outdoors

where long life and low maintenance costs are

desired.

in marine applications where water spray and

corrosive atmospheres are considerations.

in petroleum refineries, chemical, petrochemical

and other heavy process industry facilities.

in heavy process industries having environments

where flammable or explosive vapors or gases, or

where combustible dusts are present.

Features

The body and mounting box are wired with flame-

proof EFCX flexible coupling.

The body is one piece casting and the front flame

incorporated with front glass and guard is hinged

and fixed to the front of the body.

The ballast is high quality one maintaining much

safety on strength of enclosure.

The mounting box has a turning base plate on the

top and a large access cover for wiring on the

side.

Standard Materials Certification Compliance

Enclosure : Cast aluminium alloy

Globe : Heat resistant hard glass

Reflector : High purity aluminium

Guard : Stainless steel

Ballast Housing : Steel

Mounting Box : Cast aluminium

alloy

Wiring Tube : EFCX Flexible coupling

Certified by KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas

Safety Corporation), and the

others.

IEC 60079-0, 1

NEMA 3, 3R, 4, 4X, 7

IP 55

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color,

contact us please.

Technical Data WeightElectrical Rating Catalog No. Weight

Rated Voltage AC110V/ 220V/ 240V ( See Below)※ EXNFD 43040 45.4 ㎏

Rated Wattage 150W/ 175W/ 200W/ 250W/ 400W

Rated Frequency 50Hz/ 60Hz Projection Angle AdjustmentEntry Size 1/2", 3/4", 1" Vertical 35° up, 45°down

Also you can order various voltage : ※

120V/ 208V/ 277V/ 460V

Horizontal 60° right and left

If you need more information, contact us please. ⇨

Page 101: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number Ordering Information

Lamp Watt Ordering No. Certification E X N F D 4 3 0 1 5 ① ② ③

High

Pressure

Sodium

150 EXNFD 43015

Ex d IIB T3

EXFD Flood Lighting Fixture① 200 EXNFD 43020

- EXMFD - Mercury Vapour

250 EXNFD 43025 - EXNFD - High Pressure Sodium

- EXHFD - Metal Halide400 EXNFD 43040

Metal

Halide

175 EXHFD 44017

Ex d IIB T2

: ② Lamp Type : Lamp Wattage (W)③

420 - Mercury Vapour 15 - 150250 EXHFD 44025

430 - H.P. Sodium 17 - 175400 EXHFD 44040

440 - Metal Halide 20 - 200

Mercury

Vapor

200 EXMFD 42020

Ex d IIB T3

25 - 250

40 - 400250 EXMFD 42025

400 EXMFD 42040

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

<EXNFD 43025> 0 1657.5 50 15.0

5 862.5 55 5.0Lamp : High pressure sodium +

250W

Bare lamp Lumen : 25000 lm+

Reflector : aluminum reflector+

10 390.0 60 5.0

15 252.5 65 2.5

20 225.0 70 2.5

25 187.5 75 2.5

30 152.5 80 0.0

35 125.0 85 0.0

40 72.5 90 0.0

45 42.5

Dimension

< EXFD >

Page 102: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Flood Lighting Fixtures

VQFD/VRFD Series

Wet Locations

NEMA 3, 3R, 4, 4X, 7

Type of Explosion-proof

<VRFD> <VQFD>

Non Sparking (Ex nR II T3 IP66)

Application

VQFD Series flood lighting fixtures are used ;

at refineries, chemical, pharmaceutical and

petrochemical plants, waste and sewage treatment

plants, pulp and paper mills and other industrial

facilities containing hazardous (classified) areas.

at light process areas, storage tank and rack areas,

loading docks, rail yards, building perimeters, parking

areas, vehicle and pedestrian passageways and even

sports applications.

for security and safety lighting in industrial and process

facilities.

In industrial locations where the damaging effects of

rain, snow, wind, moisture, dirt, corrosion, vibration and

rough usage may be a problem.

to produce superior light at low cost with great

efficiency.

Accessories

Accessories

<CAM> <PWM> <SFM>

Crossarm

Mounting

Bracket

Pipe or Wall

Mounting

Bracket

Slip-Fitter

Features

Heavy duty copper free aluminum housing with epoxy

powder coat finish.

Unique 3 piece housing design.

Prewired with 3 ft. of 14/3 SO cord.

Required only two bolts to joint.

Easily adjustable to aim light where desired.

Heat and impact resistant tempered glass lens.

Heavy duty neoprene gasketing.

Anodized precision formed aluminum reflector.

NEMA 7x6 beam spread for light pattern.

Removable top plate provides easy access to lamp

compartment.

Weight

Catalog No. Weight

VQNFD 88040 27 Kg

Certification

Certified by KOSHA (Korea Occupational Safety &

Health Agency), KGS (Korea Gas Safety Corporation),

and the others.

Ballast

Standard : High efficient factor

Choke + ignitor typeStandard Materials Lamp

Housing : Cast aluminum alloy

External hardware : stainless steel

Yoke : Steel

Lens : Heat and impact resistant

tempered glass

Gasket : neoprene

Reflector : Semi-matt

HID Lamp Standard Finish

Aluminum : Epoxy powder coat

Steel (Yoke) : Hot dipped

galvanized

Stainless Steel : Natural

MUNSELL No. 7.5BG 6/1.5

If you want another color,

contact us please.

Compliance

NEMA 3 ,3R, 4, 4X, 7

IEC 60079-0, 15

IP66

Technical DataOptionsAlso you can※

order various

voltage :

120V/ 208V/

277V/ 460V

Electrical RatingBody & Cover : Pure aluminium

sheet

Constant Wattage Auto

transformer Rated Voltage

Rated Voltage AC110V/ 220V/ 240V ( See Right)※

Rated Wattage 150W/ 175W/ 200W/ 250W/ 400W

Entry Size 1/2", 3/4", 1"

Page 103: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number Ordering Information

Lamp Watt Ordering No. Certification V Q N F D 8 6 0 1 5 ① ② ③

High

Pressure

Sodium

150 VQNFD 86015

Ex nR II T3 IP66

Flood Lighting Fixture① 200 VQNFD 86020

- VQ - Ballast Box Separate Type

250 VQNFD 86025 - VR - Ballast Box Unite Type

: ② Lamp Type400 VQNFD 86040

MFD 850 - Mercury Vapour

Metal

Halide

175 VQHFD 87017 NFD 860 - H.P. Sodium

HFD 870 - Metal Halide250 VQHFD 87025

: Lamp Wattage (W)③ 400 VQHFD 87040

15 - 150

Mercury

Vapor

200 VQMFD 85020 17 - 175

20 - 200250 VQMFD 85025

25 - 250

400 VQMFD 85040 40 - 400

Photometric Data

0 -180 (Blue)˚ ˚ 90 -270 (Red)˚ ˚

Angle cd/1000 lm Angle cd/1000 lm

0 291.3 0 291.3<VQNFD 86040>10 300.0 10 258.8

Lamp : NH400 (50000 lm)+

With Globe and without Guard+ 20 303.8 20 220.0

30 240.0 30 187.5

40 165.0 40 177.5

50 120.0 50 125.0

60 75.0 60 23.8

right picture explanation☞

Blue : Normal to Lamp+

Red : Parallel to Lamp+

70 45.0 70 10.0

80 12.5 80 5.0

90 1.3 90 1.3

Dimension

< VRFD > < VQFD >

Page 104: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Flood Lighting Fixtures

EGFD Series

Wet Locations

NEMA 3, 3R, 4, 4X, 7

Type of Explosion-proof

<EGFD>

Flameproof (Ex d IIC T4 IP66)

Dust Ignition-proof (Ex DP II 12)

Application

EGFD Series flood lighting fixtures are used ;in heavy process industries having environments where flammable or explosive vapors or gases, or where combustible dusts are present.in hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired.in petroleum refineries, chemical, petrochemical and other heavy process industry facilities. in hazardous locations requiring elevated ambient capability.For mounting to a wall or structure.in mounted on a pole, when used with the SFM slipfitter adapter.

Features Standard Finish Standard Materials

Luminaire is factory wired; power

is fed through "wireless"

connection block which serves as

a mechanical seal between

conduit and ballast

compartments, eliminating the

need for an external, field

installed seal. The result is fast,

easy installation.

High bay reflectors of aluminium.

Internally fluted glass globes

reduce glare and provide

comfortable viewing light.

High power factor (90%+)

ballasts reduce power costs -

allow more luminaires per circuit.

Integral ballasts - separate

ballasts are not required. Lowest

installation cost.

Factory sealed, porcelain, mogul

base socket.

The turning arm gives you the

ability to offer a Hazard Gard

floodlight with varying degrees of

adjustability between -90 and ˚

+90 .˚

When mounting on a wall, there

are numerous mounting

arrangements -due to the

pre-drilled openings in the wall

bracket.

MUNSELL No. 7.5BG 6/1.5

If you want another color,

contact us please.

Mounting module, cover, ballast

housing, guard, globe ring : Cast

aluminium alloy

Globe : heat and impact

resistant glass

Exterior hardware : stainless steel

Lamp socket : porcelain with

stainless steel screw shell

Reflector : high bay aluminium

Compliance

IEC 60079-0, 1

NEMA 3, 3R, 4, 4X, 7

Certification

Certified by KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas Safety

Corporation), and the others.

Weight

Catalog No. Weight

EGNFD 53040 32.5 ㎏

Technical Data

Electrical Rating

Rated Voltage AC110V/ 220V/ 240V ( See Below)※

Rated Wattage 150W/ 175W/ 200W/ 250W/ 400W

Rated Frequency 50Hz/ 60Hz

Entry Size 1/2", 3/4", 1"

Also you can order various voltage : ※

120V/ 208V/ 277V/ 460V

If you need more information, contact us please. ⇨

Page 105: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number Ordering Information

Lamp Watt Ordering No. Certification E G N F D 5 3 0 1 5 ① ② ③

High

Pressure

Sodium

150 EGNFD 53015

Ex d IIC T4

Ex DP II 11

EGFD Flood Lighting Fixture① 200 EGNFD 53020

- EGMFD - Mercury Vapour

250 EGNFD 53025 - EGNFD - High Pressure Sodium

- EGHFD - Metal Halide400 EGNFD 53040 Ex d IIC T3

Metal

Halide

175 EGHFD 54017 Ex d IIC T4

Ex DP II 11

: ② Lamp Type : Lamp Wattage (W)③

520 - Mercury Vapour 15 - 150250 EGHFD 54025

530 - H.P. Sodium 17 - 175400 EGHFD 54040 Ex d IIC T3

Ex DP II 12 540 - Metal Halide 20 - 200

Mercury

Vapor

200 EGMFD 52020 Ex d IIC T4

Ex DP II 11

25 - 250

40 - 400250 EGMFD 52025

400 EGMFD 52040 Ex d IIC T3

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm

0 1370.2 50 74.5<EGNFD 53025>5 1153.8 55 36.1

Lamp : High pressure sodium +

250W

Bare lamp Lumen : 26000lm+

Reflector : Flood type +

aluminum reflector

10 769.2 60 14.4

15 459.1 65 7.2

20 288.5 70 2.4

25 199.5 75 2.4

30 149.0 80 1.7

35 122.6 85 1.2

40 105.8 90 0.5

45 93.8

Dimension

< EGFD >

Page 106: Nb cat

SECTION - 5L

Special Lighting Fixture

Page 107: Nb cat

SECTION 5L

Special Lighting Fixtures INDEX

Model

Lamp Type / Watt.

Certification for

Explosion-proof

PAGE

Incandescent HalogenCompact

Fluorescent

100 200 500 25 40 60 350 20 IEC

ETL ● ● ● ● ● Ex d B T4 HⅡ 2 IP66 5L - 1

EHDL

57/58● ● ● Ex d C T3Ⅱ 5L - 3

EHDL 55 ● Ex d B T3Ⅱ 5L - 4

WOL ● 2 ●

Ex e Ⅱ T1

Ex de CⅡ T3

Ex nR II T4

5L - 5

UWLF Underwater Lighting Fixture 5L - 6

Page 108: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Tank Inspection Lighting Fixtures

ETL Series

<ETL-H>

Type of Explosion-proof Flameproof (Ex d IIB T4 H2 IP66)

Application

ETL Series Tank lighting fixtures are used ;in illuminating stirred tank or storage tank, reactors, distillation columns, pipeline flow indicator etc.in petroleum refineries, chemical, petrochemical and other heavy process industry facilities. where an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only.

Features Standard Materials

The metal casing is composed of three part; body, front frame and terminal box.Fixing of the fittings are to be done by suitable mounting hardwares utilizing the mounting base on the front frame.Terminal is fitted to the body with spigot joint and being secured by three set crews.Easy installation and maintenance.220V power supply directly.Also can supply 110V, 240V (ordered).Incandescent lamp 100W, 200W.

Also have Halogen Lamp 25W, 40W, 60W.

Housing, mounting modules, component pallets :

Cast aluminium alloy

Front Glass : Tempered plate glass

Inner Reflector : High purity aluminium

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

Technical Data

Catalog No. ETL 4101 ETL 4102 ETL 4201 ETL-H 5101 ETL-H 5102 ETL-H 5103

Rated Voltage (V) 220 220 220 110/220 110/220/240 110/220/240

Rated Wattage (W) 100 200 100 25 40 60

Lamp Incandescent Incandescent Incandescent Halogen Halogen Halogen

Weight (kg) 2.8 4.8 2.0 2.9 2.9 2.9

Classification of

Explosion-proofEx d IIB T3 Ex d IIB T2 Ex d IIB T3

Ex d IIB T4 H2

IP66Ex d IIB T3 H2 Ex d IIB T3 H2

<ETL-H> <ETL4101> <ETL4102>

If you need more information, contact us please. ⇨

Page 109: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Photometric Data

Angle cd/1000 lm Angle cd/1000 lm<ETL 4102> 0 109.2 50 47.1

5 117.7 55 38.5Lamp : IL200(2920 lm)+ 10 115.6 60 30.0

15 113.5 65 21.4

20 109.2 70 12.8

25 104.9 75 6.4

30 96.3 80 2.2

35 77.1 85 0

40 79.2 90 0

45 57.8

Angle cd/1000 lm Angle cd/1000 lm<ETL-H 5103> 0 442.1 50 30.5

5 503.0 55 0Lamp : +

HALOGEN60(820 lm) 10 426.8 60 0

15 297.3 65 0

20 198.2 70 0

25 152.4 75 0

30 152.4 80 0

35 129.6 85 0

40 91.5 90 0

45 61.0

Dimension

<ETL-H> <ETL 4101> <ETL 4102>

Page 110: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Incandescent / Compact Fluorescent

Portable Hand Lamp

EHDL 57/58 Series

<EHDL 57>

Type of Explosion-proof

Flameproof (Ex d IIC T3)

Application

EHDL Series portable handlamps are used ;

as portable handlamp in hazardous area.

in inspecting aircraft wing tanks, vats, process

vessels, fuel tanks, etc.

Features

The metal casing consists of a body, globe holder

and terminal box, and provides a flameproof cable

gland at the top of the terminal box.

The globe holder firmly attached with globe and

guard is screwed onto the body and locked by one

socket head screw.

Choose incandescent lamp/compact fluorescent lamp.

Standard Materials Compliance

Body : Cast aluminium alloy

Globe : Heat-resistant hard glass

Handle : PVC

IEC 60079-0, 1

CertificationStandard Finish Certified by KOSHA (Korea Occupational Safety &

Health Agency), KGS(Korea Gas Safety Corporation),

and the others.MUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

Technical Data

Catalog No. Rated Voltage(V) Rated Wattage (W) Lamp Weight (kg) Certification

EHDL 57 Max. 230 100 Incandescent 2.5 Ex d IIC T3

EHDL 58F Max. 230 20 Compact Fluorescent 2.7 Ex d IIC T6

Photometric Data Dimension

Angle EHDL 57 EHDL 58F Angle EHDL 57 EHDL 58F

0 90.0 22.7 50 85.0 68.2

5 75.0 22.7 55 85.0 73.9

10 75.0 28.5 60 90.0 79.5

15 90.0 28.5 65 105.0 79.5

20 80.0 34.1 70 90.0 85.3

25 75.0 34.1 75 85.0 85.3

30 80.0 45.5 80 85.0 85.3

35 85.0 51.2 85 85.0 85.3

40 85.0 56.8 90 80.0 85.3

45 95.0 62.5 cd/1000 lm

Blue = Incandescent Lamp 100W (1250 lm)

Red = Compact Fluorescent Lamp 20W (1200 lm)

Page 111: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Incandescent Portable Hand Lamp

EHDL 55

<EHDL 55>

Type of Explosion-proof

Flameproof (Ex d IIB T3)

Application

EHDL Series portable handlamps are used ;

as a portable handlamp in hazardous area.

where an explosive atmosphere consisting of a

mixture with air of flammable substances in the form

of gas, vapour or mist is not likely to occur in

normal operation but, if it does occur, will persist for

a short period only.

in inspecting aircraft wing tanks, vats, process

vessels, fuel tanks, etc.

Standard Materials Features

Body : Cast aluminium alloy

Globe : Heat-resistant hard glass

Guard : Stainless steel

The metal casing consists of a body, globe holder

and terminal box, and provides a flameproof cable

gland at the top of the terminal box.

The globe holder firmly attached with globe and

guard is screwed onto the body and locked by one

socket head screw.

The terminal box is fitted to the body with spigot

joint and is secured by two socket head screws.

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

Technical Data

Catalog No. Rated Voltage (V) Rated Wattage (W) Lamp Weight (kg) Certification

EHDL 5501 110/220 100 Incandescent 2.8 Ex d IIB T3

Dimension

Angle cd/1000 lm Angle cd/1000 lm

0 35.0 50 35.0

5 25.0 55 45.0

10 25.0 60 50.0

15 30.0 65 50.0

20 40.0 70 55.0

25 40.0 75 55.0

30 40.0 80 50.0

35 45.0 85 45.0

40 45.0 90 20.0

45 35.0

<EHDL 5501>

[Lamp : IL100] [1×1250 lm]

Page 112: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Obstruction Lighting Fixtures

WOL Series

Type of Explosion-proof

<502> <200,000 cd> <SWOL101>

<EWOL 101>

Flameproof-Increase Safety (Ex de IIC T4)

Increase Safety (Ex e II T1)

Non sparking (Ex nR II T4)

Application

WOL Series Obstruction lighting fixtures are used ;

in petroleum refineries, chemical, petrochemical and

other heavy process industry facilities.

where an explosive atmosphere consisting of a

mixture with air of flammable substances in the form

of gas, vapour or mist is not likely to occur in

normal operation but, if it does occur, will persist for

a short period only.

Features Standard Materials

Easy installation and maintenance.

220V power supply directly.

Also can supply 110V, 240V (ordered).

Standard type is Increase Safety. can order made

Flameproof-Increase Safety type

Housing : Cast aluminium alloy

Globe : Heat resistant hard glass

Mounting Box : Cast aluminium alloy

Standard FinishNavigation Red

If you want another color, contact us

please.

Technical Data

Catalog No. SWOL 101 SWOL 502 SWOL 200,000cd EWOL 101 EWOL 502

Rated Voltage (V) 110/ 220 110/ 220 220 110/220 110/220

Rated Wattage (W) 100W ×1 500W ×2 350W 100W 500W ×2

Lamp Incandescent Incandescent Xenon Incandescent Incandescent

Weight (kg) 5.8 Kg 53 Kg 21 Kg 5.8 Kg 53 Kg

Classification of

Explosion-proofEx e II T1 Ex e II T1 Ex e II T4 Ex d IIB T4 Ex de IIC T3

Dimension

< 200,000cd >

< 502 >

< SWOL101 >

< EWOL 101 >

If you need more information, contact us please. ⇨

Page 113: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2004

Underwater Lighting Fixture

UWL SeriesNuclear containment-grade materials

General InformationThe NAMBUK underwater lighting fixture model UWL

series are designed for underwater use in nuclear

plant fuel pool.

While widely used as a general area lighting fixture

in new and spent fuel pools, it is also used for

localized inspection and for in-core use during refuel

operations, etc.

<UWLF>

Features

<LP-P>

Brilliant illumination, with two sealed beam lamp

Easy maintenance.

All stainless steel "inside-containment" construction

Integral underwater connectors, designed for easy

operation

With pin type lamp (LP-P) or socket type lamp

(LP-S)

Lamp & Base

<LP-S>

PAR 64 Sealed Beam Lamp

Beam Angle : Wide(Standard), Midium, Narrow

LP-P : 120V, 1000W, Pin Type Base

LP-S : 120V, 1000W, E39 Socket Type Base

<FUW>

Standard Materials Body : 304 Stainless steel

Bracket : 304 Stainless steel

Cable : SOOW (Other cables are order made)

Standard FinishNatural

Technical Data

Model No. Voltage (V) Wattage (W) Lamp Base

UWLF 1000 Max. 120 2 × 1000W Sealed Beam Pin Type

UWLS 1000 Max. 120 2 × 1000W Sealed Beam E39 Socket Type

Dimension

Page 114: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2011

Obstruction Lighting Fixtures

EWOL Series

Panel for Obstruction Lighting

OLCP Series

Type of Explosion-proof

<EWOL-AB-LE> <EWOL-AB-XL> <EWOL-AB-LE>

Flameproof (Ex d IIB T6 IP66)

Flameproof (Ex d IIC T6 IP66)

Dust Protection (Ex tD A21 IP66 T85℃)

Application

WOL Series Obstruction lighting fixtures are used ;

in petroleum refineries, chemical, petrochemical

and other heavy process industry facilities.

where an explosive atmosphere consisting of a

mixture with air of flammable substances in the

form of gas, vapour or mist is not likely to

occur in normal operation but, if it does occur,

will persist for a short period only.

Features Standard Materials

Easy installation and maintenance.

240VAC/24VDC power supply directly.

Others voltage is order made.

Housing : Cast aluminium alloy

Globe : Heat resistant hard glass

Mounting Box : Cast aluminium alloy

Standard Finish

Navigation Red

If you want another color, contact us please.

Compliance CertificationIEC/EN 60079-0, 1

IEC/EN 61241-0, 1

ICAO Standard

IP 66

INERIS 11 ATEX 0039X by INERIS (EWOL-AB-LE)

INERIS 11 ATEX 0037X by INERIS (EWOL-AB-XL)

INERIS 11 ATEX 0040X by INERIS (OLCP-XL)

INERIS 11 ATEX 0038X by INERIS (OLCP-LE)

IECEx KTL 11.0007X by KTL (EWOL-AB-LE)

IECEx KTL 11.0009X by KTL (EWOL-AB-XL)

IECEx KTL 11.0010 by KTL (OLCP-XL)

IECEx KTL 11.0008 by KTL (OLCP-LE)

IECEx KTL 11.0011X by KTL (EWOL-L-LE)

Technical Data

Catalog No. EWOL-AB-XL EWOL-AB-LE EWOL-L-LE

Rated Voltage (V) Max. 240V DC 24V 220V

Rated Wattage (W) 100W × 2 100W 12W

Lamp Xenon LED LED

Light IntensityWhite 20,000 cd

200 cdRed 2,000 cd

Flashing Frequency 20 ~ 60 fpm Fixed

Ambient Temperature -20℃ ~ 55℃

Weight (kg) 54 Kg 58 Kg 5.8 Kg

Classification of

Explosion-proof

Ex d IIB T6

Ex tD A21 IP66 T85℃

Ex d IIB T6

Ex tD A21 IP66 T85℃

Ex d IIC T6

Ex tD A21 IP66 T85℃

⇨ If you need more information, contact us please.

Page 115: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2011

Dimension

<EWOL-AB-XL>

<EWOL-AB-LE>

<EWOL-L-LE>

<OLCP-XL>

<OLCP-LE>

⇨ If you need more information, contact us please.

Page 116: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2011

Street Lighting Fixtures

HA-L-B Series

Features Standard Materials

H.I.D lighting fixture has internal type ballast.

This type is designed to be suitable for mounting

arm of 55~63mm OD

Body : Die casting aluminium

Globe : Heat resistant hard glass

Inner Reflector : Aluminium

Standard Finish Certification

MUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

Certified by CE

Compliance

IP65

Technical Data

Electrical Ratings

Rated Voltage AC110V/ 220V/ 230V/ 240V

Rated Wattage 150W/ 175W/ 200W / 250W

Rated Frequency 50Hz/ 60Hz

※ Also you can order various voltage :

120V/ 208V/ 277V/ 460V

Ordering Number Dimension

Lamp Watt Catalog No.

High

Pressure

Sodium

150 HANL 150B

200 HANL 200B

250 HANL 250B

Metal

Halide

175 HAHL 175B

250 HAHL 250B

Mercury

Vapor

200 HAML 200B

250 HAML 250B

⇨ If you need more information, contact us please.

Page 117: Nb cat

M

Angle Lux C.P Angle Lux C.P Angle Lux C.P Angle Lux C.P0 390 2,437.5 0 390 2,437.5 0 390 2,437.5 0 390 2,437.5

5 391 2,443.8 5 391 2,443.8 5 415 2,593.8 5 391 2,443.8

10 388 2,425.0 10 388 2,425.0 10 425 2,656.3 10 362 2,262.5

15 385 2,406.3 15 385 2,406.3 15 460 2,875.0 15 335 2,093.8

20 471 2,943.8 20 471 2,943.8 20 625 3,906.3 20 271 1,693.8

25 536 3,350.0 25 536 3,350.0 25 665 4,156.3 25 215 1,343.8

30 586 3,662.5 30 586 3,662.5 30 530 3,312.5 30 200 1,250.0

35 689 4,306.3 35 689 4,306.3 35 412 2,575.0 35 165 1,031.3

40 765 4,781.3 40 765 4,781.3 40 350 2,187.5 40 135 843.8

45 799 4,993.8 45 799 4,993.8 45 320 2,000.0 45 118 737.5

50 680 4,250.0 50 680 4,250.0 50 295 1,843.8 50 105 656.3

55 501 3,131.3 55 501 3,131.3 55 225 1,406.3 55 95 593.8

60 360 2,250.0 60 360 2,250.0 60 168 1,050.0 60 75 468.8

65 245 1,531.3 65 245 1,531.3 65 155 968.8 65 51 318.8

70 168 1,050.0 70 168 1,050.0 70 115 718.8 70 35 218.8

75 135 843.8 75 135 843.8 75 75 468.8 75 25 156.3

80 85 531.3 80 85 531.3 80 65 406.3 80 15 93.8

85 62 387.5 85 62 387.5 85 25 156.3 85 12 75.0

90 25 156.3 90 25 156.3 90 15 93.8 90 8 50.0

NAM BUK ELECTRIC Co., LTD.

A, C B, D

SYMMETRY(0-A, CW) SYMMETRY(0-B, CCW) ASYMMETRY(0-C, CW) ASYMMETRY(0-D, CCW)

REMARK AD CB

HA – L – B (신형가로등) NH150W 사용UL 인증예정품

* C.P : Lux * (DISTANCE)2

STANDARD LAMP NH150 / 14000Lm DISTANCE 2.5

INSPECTOR CHA.Y.H D A T E 2012년 2월 6일

PHOTOMETRIC DATA

I T E M HA-L-B MODEL No.

S I Z E AC220V/60Hz Tamb. 10

Page 118: Nb cat

M

Angle Lux C.P Angle Lux C.P Angle Lux C.P Angle Lux C.P0 758 4,737.5 0 758 4,737.5 0 758 4,737.5 0 758 4,737.5

5 762 4,762.5 5 762 4,762.5 5 762 4,762.5 5 742 4,637.5

10 721 4,506.3 10 721 4,506.3 10 792 4,950.0 10 725 4,531.3

15 718 4,487.5 15 718 4,487.5 15 835 5,218.8 15 579 3,618.8

20 748 4,675.0 20 748 4,675.0 20 945 5,906.3 20 510 3,187.5

25 768 4,800.0 25 768 4,800.0 25 1,042 6,512.5 25 410 2,562.5

30 815 5,093.8 30 815 5,093.8 30 780 4,875.0 30 365 2,281.3

35 905 5,656.3 35 905 5,656.3 35 685 4,281.3 35 289 1,806.3

40 1,052 6,575.0 40 1,052 6,575.0 40 602 3,762.5 40 241 1,506.3

45 1,225 7,656.3 45 1,225 7,656.3 45 542 3,387.5 45 182 1,137.5

50 1,100 6,875.0 50 1,100 6,875.0 50 385 2,406.3 50 156 975.0

55 901 5,631.3 55 901 5,631.3 55 312 1,950.0 55 115 718.8

60 712 4,450.0 60 712 4,450.0 60 255 1,593.8 60 85 531.3

65 472 2,950.0 65 472 2,950.0 65 185 1,156.3 65 68 425.0

70 251 1,568.8 70 251 1,568.8 70 125 781.3 70 52 325.0

75 165 1,031.3 75 165 1,031.3 75 75 468.8 75 31 193.8

80 75 468.8 80 75 468.8 80 52 325.0 80 21 131.3

85 56 350.0 85 56 350.0 85 32 200.0 85 15 93.8

90 25 156.3 90 25 156.3 90 12 75.0 90 6 37.5

NAM BUK ELECTRIC Co., LTD.

A, C B, D

SYMMETRY(0-A, CW) SYMMETRY(0-B, CCW) ASYMMETRY(0-C, CW) ASYMMETRY(0-D, CCW)

REMARK AD CB

HA – L – B (신형가로등) NH-250 사용UL 인증예정품

* C.P : Lux * (DISTANCE)2

STANDARD LAMP NH 250 / 25000Lm DISTANCE 2.5

INSPECTOR CHA.Y.H D A T E 2012년 2월 6일

PHOTOMETRIC DATA

I T E M HA-L-B MODEL No.

S I Z E AC220V/60Hz Tamb. 10

Page 119: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2011

LED Lighting Fixtures

ELE Series

with High Efficiency LED

New Product

Type of Explosion-proof

Flameproof (Ex d IIC T6 IP66)

Description

The explosion protected lighting fixtures for

Power LED light is in according to the

IEC60079-1, 0.

This product is certified for use in the Zone 1

and 2, made of aluminium alloy and

aluminium die casting with a powdered

coating.

Power LED lighting fixture is designed for

outdoor use.

Especially, It's for chemical factories, offshore

platforms and illuminating large areas.

Features Technical DataNew lighting source is Power LED 120W/135W

(12 PCB Modules)

Long life time ( 50000 hour in LED only )

Light on and light out immediately

Ambient temperature -20℃ to 40℃

Electrical Rating

Rated Voltage AC 220 VAC ~ 260 VAC

Input Wattage 135 W / 150W

Output Wattage 120 W / 135W

Rated Frequency 50Hz/ 60Hz

Entry Size 1/2" , 3/4" , 1" Compliance & Certification Weight 22kg ( Full set )IEC 60079-0, 1

Ex d IIC T6 IP66

Certitied by KOSHA ( Korea Occupational

Safety & Health Agency )

Standard MaterialsEnclosure: Aluminium Die-casting

Globe: Heat resistant hard glass

Guard: Stainless Steel

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please

Chromating Photometric Data

Angle C.P Angle C.P

<ELE 135> 0 3,531 50 2,256

5 3,475 55 1,963+Lamp : LED 135W

+With Globe 10 3,250 60 1,719

15 3,263 65 1,500

20 3,213 70 1,175

Lamp WattConversion

Factor25 3,206 75 719

30 3,067 80 406

120 0.75

35 3,019 85 156

40 2,969 90 44

45 2,631

⇨ If you need more information, contact us please.

Page 120: Nb cat

Lighting Fixture

Copyright by NAMBUK Electric Co., LTD. 2011

Ordering Number

Lamp WattHub

SizePendant Ceiling Bracket Stanchion Certification

LED

120

1" ELE LE 1121 ELE LE 2121 ELE LE 3121 ELE LE 4121

Ex d IIC T6 IP66

3/4" ELE LE 1123 ELE LE 2123 ELE LE 3123 ELE LE 4123

1/2" ELE LE 1125 ELE LE 2125 ELE LE 3125 ELE LE 4125

135

1" ELE LE 1131 ELE LE 2131 ELE LE 3131 ELE LE 4131

3/4" ELE LE 1133 ELE LE 2133 ELE LE 3133 ELE LE 4133

1/2" ELE LE 1135 ELE LE 2135 ELE LE 3135 ELE LE 4135

Ordering Information

E LE LE 1 1 2 1 / 2 6 ① ② ③ ④ ⑤ ⑥

① ELE Lighting Fixture ⑤ Entry Size

1 - 1"

② Lamp Type 3 - 3/4"

LE - LED 5 - 1/2"

③ Mounting Type

1 - Pendant ⑥ Input Voltage (V)

2 - Ceiling 22 - 220V

3 - Bracket 24 - 240V

4 - Stanchion 25 - 250V

26 - 260V

④ Lamp Wattage (W)

12 -120W

13 -135W

Dimension

< 40° Bracket Type> < 90° Bracket Type > < Ceiling Type > < Pendant Type >

Page 121: Nb cat
Page 122: Nb cat
Page 123: Nb cat
Page 124: Nb cat
Page 125: Nb cat
Page 126: Nb cat

SECTION - 1C

Combination Station

Page 127: Nb cat

SECTION 1C

Combination Station INDEX

Model Product DescriptionCertification for

Explosion-proofPAGE

ECS

Control unit combination

Rectangular Type

Ex d B T6Ⅱ

(EPB, ESS :

Class I Group C,D

Class II Group EFG)

1C - 3

ESCControl unit combination

Circular TypeEx d C T6 IP55Ⅱ 1C - 5

VGN Various Kind of control unit combination Vapor tight Type 1C - 7

VEGN Various Kind of control unit combination Ex de IIC T6 1C - 9

EGN Various Kind of control unit combination Ex d B T6Ⅱ 1C - 11

EFCS Engineering Plastic Combination Stations Ex de C T6 IP66Ⅱ 1C - 13

Page 128: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Combination Switch

ECS, ESC Series

Wet Locations

NEMA 3,3R,4,4X,7,9

< ECS Series >

< ESC Series >

Application Features

Industrial areas such as chemical plants, oil and gas

refineries, paint and vanish manufacturing plants,

gasoline bulk loading terminals, grain elevators, grain

processing industries, coal processing or handling areas

where atmospheres may contain hazardous gases or

dusts and arcing of enclosed devices must not ignite

the surrounding atmosphere.

Controlling and supplying energy to portable electrical

devices such as motor generator sets, compressors,

conveyors, portable tools, etc.

These are the combinations of meters, pilot lights

(Single or double), Cam switches, Selector switches and

Push button switches (single or double), the main

enclosures of which are fitted to the terminal boxes of

two or three gangs.

This range of all units has complete interchangeability in

the joints between the main enclosures and the terminal

boxes, so that any combination is available. When a

combination other than listed in the tables is required,

specify the units to be combined.

The flameproof enclosure are composed of the main

body and cover with four hexagonal headed bolts.

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.Standard Materials

Terminal Box : Cast aluminum alloy

Main Enclosure : Die casting aluminium

Pole : Steel pipe

Base : Cast aluminium alloy

Option

Sunshade Cover

Page 129: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Units Specification Electrical Ratings

Am-meter

Volt-meter

-The Am-meters and Volt-meters are moving iron instruments

with an accuracy class 1.5

-Standard overload scales are max.3 times

-On Am-meters for 1 and 5 Amp C.T connection

Pilot Lamp-The pilot system based on the use of luminescent diodes as

the lamp source.

LED : AC 110,220V/20mA max., DC24V

Filament Lamp : AC 110,220V/3W

Cam Switch

-Cam Switches max 4 positions are available with conventional

contactors or as a contact-free version.

-The contact arrangements can be selected, spring return or

notched positions can be supplied (refer to contact

arrangement on this page).

Contact Ratings

AC 110V 15Amp.

300V 10Amp.

440V 3Amp.

DC 24V 10Amp.

110V 5Amp.

220V 3Amp.

Selector

Switch

-Selector switches max 4 positions are available.

-The switching arrangements can be selected, spring return or

notched position are available.

AC 250V 5A Contact Rating.

Push Button

Switch

-The standard contact block is double pole, 1 NC (Normally

closed), and 1 NO (Normally Open contact)AC 250V 5A Contact Rating.

Suffix No.

For Operating Magnetic Motor Starter Suffix No.

For ON OFF or Selective Transfer Operation․

Handle Positions Contact Arrangements Handle

Positions Contact Arrangements

1 7

2 8

3 9

4 10

5 11

6 12

Explanation on Operating Diagrams in the TableIn the operating diagrams in the table above, the longitudinal dotted lines show the operating positions of switch, the small circles on the both ends of lateral line show the terminals, and the figures show the terminal numbers.The marks showing the conditions of contacts at each operating position are explained as follows:1. The contact between both terminals is closed at this position.● 2. The contact is closed successively between the two positions.3. The mark of residual contact. The contact is closed when the handle is set to this position and keeps closed ← ◉

after the handle returns. The contact is open at the fine point of the arrow mark when the handle is operated in this direction.

4. A The mark of spring return. The arrow mark shows the direction of automatic spring return form 'A' to the fine point of it.

Page 130: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Rectangular Combination Switch

ECS Series

Wet Locations

NEMA 3,3R,4,4X,7,9

Type of Explosion-proof Rating : ◎ Max. 250 Volt, Max. 5 Ampere.

EPB Push button and ESS Selector S/W are

UL Listed.Flameproof (Ex d IIB T6)

Class I Group CD Class II Group EFG

1 Gang

No. of

Gangs

Unit Arrangement Catalog Number

MeterPilot Lamp Cam

Switch

Selector

Switch

Push ButtonWall Mounting Standing

Single Double Single Double

1 Gang

○ ECS 101 ECS 101T

○ ECS 102 ECS 102T

○ ECS 103 ECS 103T

○ ECS 104 ECS 104T

○ ECS 105 ECS 105T

○ ECS 106 ECS 106T

○ ECS 107 ECS 107T

2 Gang

No. of

Gangs

Unit Arrangement Catalog Number

MeterPilot Lamp Cam

Switch

Selector

Switch

Push Button Wall mounting Standing

Single Double Single Double Horizontal Vertical Vertical

2 Gang

○ ○ ECS 201 ECS 201V ECS 201T

○ ○ ECS 202 ECS 202V ECS 202T

○ ○ ECS 203 ECS 203V ECS 203T

○ ○ ECS 204 ECS 204V ECS 204T

○ ○ ECS 205 ECS 205V ECS 205T

○ ○ ECS 206 ECS 206V ECS 206T

○ ○ ECS 207 ECS 207V ECS 207T

○ ECS 208 ECS 208V ECS 208T

○○ ECS 209 ECS 209V ECS 209T

○ ○ ECS 210 ECS 210V ECS 210T

○ ○ ECS 211 ECS 211V ECS 211T

○ ○ ECS 212 ECS 212V ECS 212T

○○ ECS 213 ECS 213V ECS 213T

○ ECS 214 ECS 214V ECS 214T

○○ ECS 215 ECS 215V ECS 215T

Page 131: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

3 Gang

3 Gang Horizontal Type

No. of

Gangs

Unit Arrangement Catalog Number

MeterPilot Lamp Cam

Switch

Selector

Switch

Push Button Wall mounting Standing

Single Double Single Double Horizontal Vertical Vertical

3 Gang

○ ○ ○ ECS 301 ECS 301V ECS 301T

○ ○ ○ ECS 302 ECS 302V ECS 302T

○ ○ ○ ECS 303 ECS 303V ECS 303T

○ ○ ○ ECS 304 ECS 304V ECS 304T

○ ○ ○ ECS 305 ECS 305V ECS 305T

○ ○ ○ ECS 306 ECS 306V ECS 306T

○ ○ ○ ECS 307 ECS 307V ECS 307T

○ ○ ○ ECS 308 ECS 308V ECS 308T

○ ○ ○ ECS 309 ECS 309V ECS 309T

○ ○ ○ ECS 310 ECS 310V ECS 310T

Standing Type

<2 Gang Vertical Type>

<3 Gang Vertical Type>

<4 Gang Type>

* ECS 4 Gang is order made.

Contact us please.

Ordering Information

E C S 2 1 4 T ① ② ③ ④

Flameproof ECS Combination Stations① Combination Type③

Gang number② Style Type④

100 Series : 1 Gang None : Wall Mounting Horizontal Type

200 Series : 2 Gang V : Wall Mounting Vertical Type

300 Series : 3 Gang T : Standing Vertical Type

400 Series : 4 Gang (Order made)

Page 132: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Circular Combination Switch

ESC Series

Wet Locations

NEMA 3,3R,4,4X,7,9

Type of Explosion-proof Rating : ◎ Max. 250 Volt, Max. 5 Ampere.

Flameproof (Ex d IIC T6 IP55)

1 Gang

No. of

Gangs

Unit Arrangement Catalog Number

MeterPilot Lamp Cam

Switch

Selector

Switch

Push ButtonWall Mounting Standing Type

Single Double Single Double

1 Gang

○ ESC 101 ESC 101T

○ ESC 102 ESC 102T

○ ESC 103 ESC 103T

○ ESC 104 ESC 104T

○ ESC 105 ESC 105T

○ ESC 106 ESC 106T

○ ESC 107 ESC 107T

* Emergency Switch Unit and Buzzer Unit are order made.

2 Gang

No. ofGangs

Unit Arrangement Catalog Number

MeterPilot Lamp Cam

SwitchSelectorSwitch

Push Button Wall mounting Standing

Single Double Single Double Horizontal Vertical Vertical

2 Gang

○ ○ ESC 201 ESC 201V ESC 201T

○ ○ ESC 202 ESC 202V ESC 202T

○ ○ ESC 203 ESC 203V ESC 203T

○ ○ ESC 204 ESC 204V ESC 204T

○ ○ ESC 205 ESC 205V ESC 205T

○ ○ ESC 206 ESC 206V ESC 206T

○ ○ ESC 207 ESC 207V ESC 207T

○ ESC 208 ESC 208V ESC 208T

○○ ESC 209 ESC 209V ESC 209T

○ ○ ESC 210 ESC 210V ESC 210T

○ ○ ESC 211 ESC 211V ESC 211T

○ ○ ESC 212 ESC 212V ESC 212T

○○ ESC 213 ESC 213V ESC 213T

○ ESC 214 ESC 214V ESC 214T

○○ ESC 215 ESC 215V ESC 215T

* Emergency Switch Unit and Buzzer Unit are order made.

Page 133: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

3 Gang

No. ofGangs

Unit Arrangement Catalog Number

MeterPilot Lamp Cam

SwitchSelectorSwitch

Push Button Wall mounting Standing

Single Double Single Double Horizontal Vertical Vertical

3 Gang

○ ○ ○ ESC 301 ESC 301V ESC 301T

○ ○ ○ ESC 302 ESC 302V ESC 302T

○ ○ ○ ○ ESC 303 ESC 303V ESC 303T

○ ○ ○ ESC 304 ESC 304V ESC 304T

○ ○ ○ ESC 305 ECS 305V ECS 305T

○ ○ ○ ESC 306 ESC 306V ESC 306T

○ ○ ○ ESC 307 ESC 307V ESC 307T

○ ○ ○ ESC 308 ESC 308V ESC 308T

○ ○ ○ ESC 309 ESC 309V ESC 309T

○ ○ ○ ESC 310 ESC 310V ESC 310T

* Emergency Switch Unit and Buzzer Unit are order made.

Standing Type

2 Gang Vertical Type

3 Gang Vertical Type

<4 Gang Type>

* ESC 4 Gang is order made.

Contact us please.

Ordering Information

E S C 2 1 4 V ① ② ③ ④

Flameproof ESC Combination Stations① Combination Type③

Gang number② Style Type④

100 Series : 1 Gang None : Wall Mounting Horizontal Type

200 Series : 2 Gang V : Wall Mounting Vertical Type

300 Series : 3 Gang T : Standing Vertical Type

400 Series : 4 Gang (Order made)

Page 134: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Vaportight Combination Stations

VGN Series

Weatherproof Type

NEMA 3,3R,4,4X,7,9

Rating : ◎ Max. 250 Volt, Max. 5 Ampere.

Application Features

VGN Series combination stations are used in;

as enclosures for Combination motor starters or

integrated type combination line starters.

as control boxes or stands which incorporate various

control switches, pilot lamps, ampere or volt meters,

selector switches, push button switches.

indoor or outdoor areas.

The box body and cover are made of cast

aluminium alloy.

They are Combination design and have enough

mechanical strength.

The cover fixing bolts are made of stainless steel.

Light weight design for easy of installation and

maintenance.

The main body and cover are secured with stainless

steel bolts through a synthetic rubber gasket,

retaining high corrosion resistant and watertightness.

The conduit entries can be arranged in desired

positions.

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

VGN200

VGN400

2, 3 Gang

TYPESDimensions(mm)

A B

VGN200 160 200

VGN300 186 216

Page 135: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

4, 5, 6 Gang

TYPESDimensions(mm)

A B

VGN400

VGN500

VGN600

210 250

8, 10, 12 Gang

TYPESDimensions(mm)

A B

VGN800

290 330VGN1000

VGN1200

Ordering Information

V G N 2 0 0 T ① ② ③

VGN Combination Stations① Style Type③

None : Wall Mounting Type

Gang number② T : Standing Type

200 Series = 2 Gang 600 Series = 6 Gang

300 Series = 3 Gang 800 Series = 8 Gang

400 Series = 4 Gang 1000 Series = 10 Gang

500 Series = 5 Gang 1200 Series = 12 Gang

Page 136: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Combination Stations

VEGN Series

Wet Locations

NEMA 3,3R,4,4X,7,9

Rating : ◎ Max. 250 Volt, Max. 5 Ampere.

Type of Explosion-proof

Flameproof-Increase Safety (Ex de IIC T6)

Application Features

VEGN Series combination stations are used in;

as enclosures for Combination motor starters or

integrated type combination line starters.

as control boxes or stands which incorporate various

control switches, pilot lamps, ampere or volt meters,

selector switches, push button switches.

indoor or outdoor areas.

The box body and cover are made of cast

aluminium alloy.

They are Combination design and have enough

mechanical strength.

The cover fixing bolts are made of stainless steel.

Light weight design for easy of installation and

maintenance.

The main body and cover are secured with stainless

steel bolts through a synthetic rubber gasket,

retaining high corrosion resistant and watertightness.

The conduit entries can be arranged in desired

positions.

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

VEGN200

VEGN400

2, 3 Gang

TYPESDimensions(mm)

A B

VEGN200 160 200

VEGN300 210 250

Page 137: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

4, 5, 6 Gang

TYPESDimensions(mm)

A B

VEGN400

VEGN500

VEGN600

210 250

8, 10, 12 Gang

TYPESDimensions(mm)

A B

VEGN800

290 330VEGN1000

VEGN1200

Ordering Information

V E G N 2 0 0 T ① ② ③

VEGN Combination Stations① Style Type③

None : Wall Mounting Type

Gang number ② T : Standing Type

200 Series : 2 Gang 600 Series : 6 Gang

300 Series : 3 Gang 800 Series : 8 Gang

400 Series : 4 Gang 1000 Series : 10 Gang

500 Series : 5 Gang 1200 Series : 12 Gang

Page 138: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Combination Stations

EGN Series

Wet Locations

NEMA 3,3R,4,4X,7,9

Rating : ◎ Max. 250 Volt, Max. 5 Ampere.

Type of Explosion-proof Flameproof (Ex d IIB T6)

Features Standard Materials

EGN type control station can be easily disassemble

main box that is composed of explosion-proof

construction and various kind of control unit into

Terminal box, and also can be easily assemble.

We meet customer's requirement by manufacture two

type, bracket type and standing type,

explosion-proof control station unit.

Main box body : Cast aluminum alloy

Main box cover : Cast aluminum alloy, Die casting Al

Terminal box : Cast aluminum alloy

Standing Base : Cast aluminium alloy

Pole : Steel pipe

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

Ordering Information

E G N A 2 1 5 ① ② ③

EGN Combination Stations Type① Gang number②

EGNA : Standard Type 200 Series : 2 Gang 1000 Series : 10 Gang

EGNF : Factory Sealed Type 300 Series : 3 Gang 1500 Series : 15 Gang

(Without Terminal Box 400 Series : 4 Gang 1800 Series : 18 Gang

in EGNA Type) 500 Series : 5 Gang 2400 Series : 24 Gang

EGNT : Standing Type 600 Series : 6 Gang 3000 Series : 30 Gang

(of EGNA Type) 900 Series : 9 Gang

Combination Type③

No. of Rows & Columns

TYPES ROWS COLUMNSEGN 200 2 1

EGN 300 3 1

EGN 400 4 1

EGN 500 5 1

EGN 600 3 2

EGN 900 3 3

EGN 1000 5 2

EGN 1500 5 3

EGN 1800 6 3

EGN 2400 4 6

EGN 3000 6 5

Page 139: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

2, 3, 4, 5 Gang

TYPESDimensions(mm)

A B C

EGNA 200 130 160 310

EGNA 300 186 216 368

EGNA 400 236 266 420

EGNA 500 286 316 465

6, 10 Gang

TYPESDimensions(mm)

A B C

EGNA 600 210 250 400

EGNA 1000 310 350 500

9, 15 Gang

 

TYPESDimensions(mm)

A B C

EGNA 900 210 250 400

EGNA 1500 310 350 500

18, 24, 30 Gang

TYPESDimensions(mm)

A B C D E

EGNA 1800 260 450 620 410 296

EGNA 2400 500 320 470 270 540

EGNA 3000 370 500 620 410 406

Page 140: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Engineering Plastic Combination Stations

EFCS Series

Wet Locations

NEMA 3,3R,4,4X,7,9

Rating : ◎ Max. 250 Volt, Max. 5 Ampere.

Type of Explosion-proof Flameproof-Increase Safety

(Ex de IIC T6 IP66)

Features Application

Enclosure in glass fiber reinforced polyester resin,

provide excellent resistant to corrosion so have a

long life.

Enclosure contains ultraviolet interception ingredient

to resist transformation.

Easy installation and maintenance.

All fixtures are designed to perform from -20 to 4

0 ambient temperature.℃

Any combination of units (1 push button switch, 2

push button switch, pilot lamps, selector switch,

ampere meters, and so on) are available.

EFCS series are used;

in manufacturing plants, refineries, chemical,

petrochemical, and other industrial process facilities,

and other industrial applications.

in areas in which ignitible concentrations of

flammable gases or vapors will be present only due

to abnormal, unusual, accidental conditions.

where combustible dust are present.

in installations where moisture, dirt, dust, vibration,

corrosion, and rough usage are problems.

wherever the damaging effects of water, wind, snow,

sleet, hot sun, or any combination of these elements

are found.Standard Finish

Dark Gray

If you want another color, contact us please.

Standard Materials Options

Main Enclosure : Glass fiber reinforced polyester resin Sunshade cover

Page 141: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Units Specification Electrical Ratings

Am-meter

Volt-meter

-The Am-meters and Volt-meters are moving iron instruments

with an accuracy class 1.5

-Standard overload scales are max.3 times

-On Am-meters for 1 and 5 Amp C.T connection

500V, n/1 or n/5A

Pilot Lamp-The pilot system based on the use of luminescent diodes as

the lamp source.

LED : AC 110,220V/20mA max.,DC24V

Filament Lamp : AC100,220V/3W

Cam Switch

-Cam Switches max 4 positions are available with conventional

contactors or as a contact-free version.

-The contact arrangements can be selected, spring return or

notched positions can be supplied (refer to contact

arrangement on this page).

Contact Ratings

AC 110V 15Amp.

300V 10Amp.

440V 3Amp.

DC 24V 10Amp.

110V 5Amp.

220V 3Amp.

Selector

Switch

-Selector switches max 4 positions are available.

-The switching arrangements can be selected, spring return or

notched position are available.

AC 250V 6A Contact Rating.

Tumbler

Switch

-Tumbler switches max 4 positions are available.

-The switching arrangements can be selected, spring return or

notched position are available.

AC 250V 6A Contact Rating.

Push Button

Switch

-The standard contact block is double pole, 1 NC (Normally

closed), and 1 NO (Normally Open contact)AC 250V 6A Contact Rating.

Illuminated

Push Button

Switch

-The illuminated push button switch is combination with pilot

lamp and push button switch.LED : AC 110,220V/20mA max., DC24V

Suffix No.

For Operating Magnetic Motor Starter Suffix No.

For ON OFF or Selective Transfer Operation․

Handle Positions Contact Arrangements Handle

Positions Contact Arrangements

1 7

2 8

3 9

4 10

5 11

6 12

Explanation on Operating Diagrams in the TableIn the operating diagrams in the table above, the longitudinal dotted lines show the operating positions of switch, the small circles on the both ends of lateral line show the terminals, and the figures show the terminal numbers.The marks showing the conditions of contacts at each operating position are explained as follows:1. The contact between both terminals is closed at this position.● 2. The contact is closed successively between the two positions.3. The mark of residual contact. The contact is closed when the handle is set to this position and keeps closed ← ◉

after the handle returns. The contact is open at the fine point of the arrow mark when the handle is operated in this direction.

4. A The mark of spring return. The arrow mark shows the direction of automatic spring return form 'A' to the fine point of it.

Page 142: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

1 Gang

Catalog No. Push Button S/W SelectorS/W

Tumbler S/W

Pilot Lamp

illuminatedPush Button

Emergency Push Button

Ampere Meter

Weight (Kg)Single Double

EFCS 101 ○ 0.45

EFCS 102 ○ 0.54

EFCS 103 ○ 0.45

EFCS 104 ○ 0.5

EFCS 105 ○ 0.46

EFCS 106 ○ 0.47

2 Gang

Catalog No.Push Button S/W Selector

S/WTumbler

S/WPilot Lamp

illuminatedPush Button

Emergency Push Button

Ampere Meter

Weight (Kg)Single Double

EFCS 201 ○○ 0.59

EFCS 202 ○ ○ 0.6

EFCS 203 ○○ 0.6

EFCS 204 ○ ○ 0.64

EFCS 205 ○ ○ 0.63

EFCS 206 ○ ○ 0.8

EFCS 207A ○ 0.66

EFCS 208 ○ ○ 0.61

EFCS 209 ○○ 0.58

EFCS 210 ○ ○ 0.7

Page 143: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

3 Gang

Catalog No.Push Button S/W Selector

S/WTumbler

S/WPilot Lamp

illuminatedPush Button

Emergency Push Button

Ampere Meter

Weight (Kg)Single Double

EFCS 301 ○ ○○ 0.83

EFCS 302 ○ ○○ 0.85

EFCS 303 ○ ○○ 0.8

EFCS 304 ○○○ 0.78

EFCS 305 ○○○ 0.75

EFCS 306 ○ ○ ○ 0.84

EFCS 307 ○○ ○ 0.84

EFCS 308 ○ ○ 0.85

EFCS 309 ○ ○ 0.9

EFCS 310 ○ ○ ○ 0.84

EFCS 311 ○○ ○ 0.8

EFCS 312 ○ ○ ○ 0.85

EFCS 313 ○○○ 0.8

12, 28 Gang

Catalog No. Units

EFCS 1200 pilot lamp/ push button S/W(single)/ push button S/W(double)/ emergency push button S/W

ampere meter/ selector S/W(small)/ Tumbler S/W(small)/ illuminated push button S/W and so on.EFCS 2800

Page 144: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

ComponentCat. No. Designation Specification

EFPBPush Button Switch

Component

A Contact (NO : Normally Open)

B Contact (NC : Normally Close)

Max. AC 250V/ 6A

Assembly with PB, DB, IB, EB

EFPLPilot Lamp

Component

AC 110 ~ 250V/ DC 24V/ 20mA

Assembly with PL, IB

EFSSSelector Switch

Component

Max. AC 250V/ 6A

Up to 4 poles

In latching or spring return form

Assembly with SS, SL

EFSCCam Switch

Component

Max. AC 250V/ 6A

Up to 4 poles

In latching or spring return form

Assembly with SS, SL

No.For Operating Magnetic Motor Starter

No.For ON OFF or Selective Transfer Operation․

Handle Positions Contact Arrangements Handle

Positions Contact Arrangements

1 7

2 8

3 9

4 10

5 11

6 12

13

Explanation on Operating Diagrams in the TableIn the operating diagrams in the table above, the longitudinal dotted lines show the operating positions of switch, the small circles on the both ends of lateral line show the terminals, and the figures show the terminal numbers.The marks showing the conditions of contacts at each operating position are explained as follows:1. The contact between both terminals is closed at this position.● 2. The contact is closed successively between the two positions.3. The mark of residual contact. The contact is closed when the handle is set to this position and keeps closed ← ◉

after the handle returns. The contact is open at the fine point of the arrow mark when the handle is operated in this direction.

4. A The mark of spring return. The arrow mark shows the direction of automatic spring return form 'A' to the fine point of it.

Page 145: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Actuator

Cat. No. Designation Specification

PL Pilot Lamp Color : Yellow/ Red/ Green/ White

PB Push Button SwitchMarking : On/ Off/ Start/ Stop/ Close/ Open/ Auto/

Manual

DB Double Push ButtonMarking : On/ Off/ Start/ Stop/ Close/ Open/ Auto/

Manual

IB Illuminated Push Button Color : Yellow/ Red/ Green/ White

EB Emergency Push Button Color : Red

SS Small Selector Switch Marking : On/ Off/ Start/ Stop/ Close/ Open/ Auto

Manual

SL Large Selector Switch Marking : On/ Off/ Start/ Stop/ Close/ Open/ Auto

Manual

Page 146: Nb cat

SECTION - 2C

Control Switch

Page 147: Nb cat

SECTION 2C

Control Switch INDEX

Model Product Description

Certification for

Explosion-proofPAGE

IEC

ETS 5 Circular Tumbler Switch Ex d C T6Ⅱ 2C - 1

ETS 6 Rectangular Tumbler Switch

Ex DP 12Ⅱ

Ex d B T6Ⅱ

Class I Group CD

Class II Group EFG

2C - 2

ELS Limit Switch Ex d IIB T6 2C - 3

EHS Hoist Switch Ex d IIB T6 2C - 3

EPC Photocell Ex d IIB T6 2C - 4

Page 148: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Type of Explosion-proof Option

Flameproof (Ex d IIC T6) Sunshade Cover

Circular Tumbler Switch

No. of

Gangs

Rated

Current

(A)

Polarity

Catalog Number

Terminal Through Way

1/2" 3/4" 1/2" 3/4"

1

10A

1Pole ETS 51111 ETS 51113 ETSC 51111 ETSC 51113

2Pole ETS 51211 ETS 51213 ETSC 51211 ETSC 51213

3Pole ETS 51311 ETS 51313 ETSC 51311 ETSC 51313

20A

1Pole ETS 51121 ETS 51123 ETSC 51121 ETSC 51123

2Pole ETS 51221 ETS 51223 ETSC 51221 ETSC 51223

3Pole ETS 51321 ETS 51323 ETSC 51321 ETSC 51323

2

10A

1Pole ETS 52111 ETS 52113 ETSC 52111 ETSC 52113

2Pole ETS 52211 ETS 52213 ETSC 52211 ETSC 52213

3Pole ETS 52311 ETS 52313 ETSC 52311 ETSC 52313

20A

1Pole ETS 52121 ETS 52123 ETSC 52121 ETSC 52123

2Pole ETS 52221 ETS 52223 ETSC 52221 ETSC 52223

3Pole ETS 52321 ETS 52323 ETSC 52321 ETSC 52323

3

10A

1Pole ETS 53113 ETSC 53113

2Pole ETS 53213 ETSC 53213

3Pole ETS 53313 ETSC 53313

20A

1Pole ETS 53123 ETSC 53123

2Pole ETS 53223 ETSC 53223

3Pole ETS 53323 ETSC 53323

4

10A

1Pole ETS 54113 ETSC 54113

2Pole ETS 54213 ETSC 54213

3Pole ETS 54313 ETSC 54313

20A

1Pole ETS 54123 ETSC 54123

2Pole ETS 54223 ETSC 54223

3Pole ETS 54323 ETSC 54323

* ETS 4 Gang Type is order made. contact us please.

Tumbler Switches

ETS Series

Wet Locations

NEMA 3,3R,4,4X,7,9

Application FeaturesETS Series are used ;

in locations, made hazardous, due to the presence of

flammable vapors, gases or highly combustible dusts.

to provide manual starting and stopping and in the case of

ETS units with heaters motor running protection.

for installation at petroleum refineries, chemical and

petrochemical plants and in other process industry facilities

where similar hazards exist.

Max. 250 Volt, Max. 20 Ampere.

This tumbler switch is designed to take

larger insulation clearance and durability. The

tumbler switch has metallic lever with roller

to ensure long life under rough operation.

Outside lever shaft is sealed for flameproof,

as well as waterproof, to ensure smooth

operation.

Standard Finish Standard Materials MUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

Main Box : Cast aluminum alloy

Surface Cover : Die casting aluminium

Page 149: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Type of Explosion-proof OptionFlameproof (Ex d IIB T6)

Class I Group CD Class II Group EFG

Dust Ignition-proof (Ex DP II 12)

Sunshade Cover

UL File No. E164350

UL Model name is ETS 5.

Rectangular Tumbler Switch

No. of

Gangs

Rated

Current

(A)

Polarity

Catalog Number

Terminal Through Way

1/2" 3/4" 1/2" 3/4"

1

10A

1Pole ETS 61111 ETS 61113 ETSC 61111 ETSC 61113

2Pole ETS 61211 ETS 61213 ETSC 61211 ETSC 61213

3Pole ETS 61311 ETS 61313 ETSC 61311 ETSC 61313

20A

1Pole ETS 61121 ETS 61123 ETSC 61121 ETSC 61123

2Pole ETS 61221 ETS 61223 ETSC 61221 ETSC 61223

3Pole ETS 61321 ETS 61323 ETSC 61321 ETSC 61323

2

10A

1Pole ETS 62111 ETS 62113 ETSC 62111 ETSC 62113

2Pole ETS 62211 ETS 62213 ETSC 62211 ETSC 62213

3Pole ETS 62311 ETS 62313 ETSC 62311 ETSC 62313

20A

1Pole ETS 62121 ETS 62123 ETSC 62121 ETSC 62123

2Pole ETS 62221 ETS 62223 ETSC 62221 ETSC 62223

3Pole ETS 62321 ETS 62323 ETSC 62321 ETSC 62323

3

10A

1Pole ETS 63113 ETSC 63113

2Pole ETS 63213 ETSC 63213

3Pole ETS 63313 ETSC 63313

20A

1Pole ETS 63123 ETSC 63123

2Pole ETS 63223 ETSC 63223

3Pole ETS 63323 ETSC 63323

4

10A

1Pole ETS 64113 ETSC 64113

2Pole ETS 64213 ETSC 64213

3Pole ETS 64313 ETSC 64313

20A

1Pole ETS 64123 ETSC 64123

2Pole ETS 64223 ETSC 64223

3Pole ETS 64323 ETSC 64323

* ETS 4 Gang Type is order made. contact us please.

Page 150: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Special SwitchesELS, EHS, EPC Series

Wet Locations

NEMA 3,3R,4,4X,7,9

Limit Switches ELS Series

Type of Explosion-proof Flameproof (Ex d IIB T6)

<ELS-L2>

<ELS-L3>

<ELS-L4>

Application

ELS Limit switches are used in areas which are hazardous due

to the presence of flammable vapors or gases and combustible

dusts such as petrochemical plant, thermal power station, oil

refineries, chemical plant and manufacturing paint plant.

Standard Material Body : Cast aluminum alloy

Standard FinishMUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

Certification

Certified by KOSHA (Korea Occupational Safety & Health

Agency), KGS (Korea Gas Safety Corporation), and the

others.

Compliance Ordering Number

IEC 60079-0, 1 Catalog No. Actuator Type

ELS-L2 Roller Lever

ELS-L3 Roller Adjust Lever

ELS-L4 Rod Lever

Hoist Switches EHS Series

Type of Explosion-proof Flameproof (Ex d IIB T6)

Standard Materials Terminal Box Cover : Cast

aluminum alloy

Body : Cast aluminum alloy

Cable Connector : Cast

aluminium alloy

Standard FinishMUNSELL No. 7.5BG 6/1.5

If you want another color,

contact us please.

Ordering NumberCatalog Number Unit Style

EHS-4 ○○○○

EHS-6 ○○○○○○

+ Other unit style are also available

on request.

Page 151: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Photocell Switches EPC Series

Type of Explosion-proof Flameproof (Ex d IIB T6)

Application

The EPC 50 remote Photocell is:

Used to provide dusk-to-dawn operation of lighting fixtures.

Used to control lighting circuits in remote locations.

Ideal for walkways, bridges, security lighting, industrial platforms, etc.

Standard Materials Standard Finish

Back Box : Cast aluminum alloy

Cover : Cast aluminum alloy

MUNSELL No. 7.5BG 6/1.5

If you want another color,

contact us please.

Technical DataInput Volt 100~120V, 200~220V

Frequence 60Hz

Contact Rating AC 120V 10AAC 208~277V 5.8A

Operation On: 50 Lux, Off: 150 Lux

Catalog Number EPC 50

Photocell Switches VPC Series

Application

The VPC 50 remote Photocell is:

Used to provide dusk-to-dawn operation of lighting fixtures.

Used to control lighting circuits in remote locations.

Ideal for walkways, bridges, security lighting, industrial platforms, etc.

Standard Materials Standard FinishBack Box : PC/ABS

Cover : PC/ABS

Natural

Technical DataInput Volt 100~120V, 200~220V

Frequence 60Hz

Contact Rating AC 120V 10AAC 208~277V 5.8A

Operation On: 50 Lux, Off: 150 Lux

Catalog Number VPC 50

Page 152: Nb cat

SECTION - 3C

Circuit Breaker Box &

Motor Starter

Page 153: Nb cat

SECTION 3C

Circuit Breaker Box & Motor Starter INDEX

Model Product Description

Certification for

Explosion-proofpage

IEC

ECM Circuit Breaker Box & Motor StarterEx d IIB T6

Ex DP II 133C - 1

ECN Circuit Breaker Box & Motor Starter Ex d IIB T6 3C - 3

EPPC Circuit Breaker Box & Motor Starter Ex d IIC T6 3C - 4

Page 154: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Circuit Breaker Box & Motor Starter

ECM Series

Wet Locations

NEMA 3,3R,4,4X,7,9

Type of Explosion-proof

Flameproof (Ex d IIB T6)

Dust Ignition-proof (Ex DP II 13)

Application

These units contain an effective magnetic motor starter conforming to the

specific standards in the flameproof main enclosures of the rectangular

shape.

The magnetic motor starters interior are manual resetting and are wired

for remote control as standard. The standard units are Through Patterns

having terminal boxes at top and bottom, and a push button for resetting

is mounted on the cover of the main enclosures. Alternatively Terminal

Pattern units having a bus-bar housing at top and a terminal box at

bottom can be supplied on request. Accessories listed in the table can

be furnished to customers' requirements.

Enclosure

Size

Dimensions (mm)Max. Conduit Size

Max. Conduit Size

mm2A B C D E F G H

SS 250 350 200 550 750 270 280 190 42(1-1/2")×2 14

MS 320 540 250 790 1040 330 440 220 42(1-1/2")×2 14

LS 500 510 310 820 1130 550 450 255 54(2")×2 38

EL 500 750 305 1055 1360 550 690 270 70(2-1/2")×2 100

* SS : Small Size, MS : Middle Size, LS : Large Size, EL : Extra Large

Features The bodies of the main enclosure and terminal boxes are

accurately machined to rectangular shape, and each of them and

their covers are closely fitted with plain flanged joints.

The operating mechanisms for the resetting button of magnetic

motor starter interior, push button and selector switch are secure

and smooth. The operating rods are machined to the required

tolerances, and an O-ring and rubber caps are provided for

preventing water and dust coming into the joints. The leading of

conductors through the barrier wall is flame-proof stud type for

main circuit and flameproof sealing type for control circuits.

Standard Materials

Main Enclosure : Cast aluminium alloy

Terminal Box : Cast aluminium alloy

Standard FinishMUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

Page 155: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Details of Motor Starters Interior

Rate Catalog No. Size

Electric Motor Terminal

Block

Standard Unit

SequenceRated Capacity

(KW)

Total Load Current (A) Push Button Pilot LampTimer

220V 440V Main On Off Red Green

220V ECM-7.5LS SS 0.05 ~ 7.5 1.2 ~ 22 - 5.5 SQ×6P ○ ○ ○ ○ - A

220V

/440V

ECM-15LS SS 7.5 ~ 15 28 ~ 55 14 ~ 28 22 SQ×6P ○ ○ ○ ○ - A

ECM-15RS MS 7.5 ~ 15 28 ~ 55 14 ~ 28 22 SQ×6P ○ ○ ○ ○ - B

ECM-15SD MS 7.5 ~ 15 28 ~ 55 14 ~ 28 22 SQ×6P ○ ○ ○ ○ ○ C

ECM-37LS MS 19 ~ 37 70 ~ 130 35 ~ 65 100 SQ×6P ○ ○ ○ ○ - A

ECM-37RS MS 19 ~ 37 70 ~ 130 35 ~ 65 100 SQ×6P ○ ○ ○ ○ - B

ECM-37SD MS 19 ~ 37 70 ~ 130 35 ~ 65 100 SQ×6P ○ ○ ○ ○ ○ C

ECM-75LS LS 45 ~ 75 160 ~ 253 80 ~ 126 150 SQ×6P ○ ○ ○ ○ - A

ECM-75RS LS 45 ~ 75 160 ~ 253 80 ~ 126 150 SQ×6P ○ ○ ○ ○ - B

ECM-75SD LS 45 ~ 75 160 ~ 253 80 ~ 126 150 SQ×6P ○ ○ ○ ○ ○ C

440V

ECM-132LS EL 90 ~ 132 305 ~ 440 150 ~ 220 200 SQ×6P ○ ○ ○ ○ - A

ECM-132RS EL 90 ~ 132 305 ~ 440 150 ~ 220 200 SQ×6P ○ ○ ○ ○ - B

ECM-132SD EL 90 ~ 132 305 ~ 440 150 ~ 220 200 SQ×6P ○ ○ ○ ○ ○ C

* LS : Line Starter

RS : Reversible Starter

SD : Star-Delta Starter

* No of terminal block in control line is on request.

* Frequency of magnetic contactor coil is 60Hz. (50Hz is on request)

Optional Accessories a : Illuminator PB

b : Aux Relay

c : Earth Leakage Breaker

d : Potential Transformer & Fuse

e : Emergency Button S/W

f : Over Current Relay

g : Hand Reset Relay

h : Automatic Reset Relay

i : Electromagnetic Contactor

j : Yellow Pilot Lamp

k : Ampere Meter

(A) Line Starting System (B) Reversible Starting System (C) Y- Starting System△

Page 156: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2003

Circuit Breaker Box & Motor Starter

ECN Series

Wet Locations

NEMA 3,3R,4,4X,7

Type of Explosion-proof Flameproof (Ex d IIB T6)

Enclosure SS MS LS EL

A 250 320 500 500

B 350 540 510 750

C 200 250 310 305

D 550 790 820 1055

E 750 1040 1130 1360

F 270 330 550 550

G 280 440 450 690

H 190 220 255 270

* SS : Small Size, MS : Middle Size,

LS : Large Size, EL : Extra Large

Features

The bodies on the main

enclosure and terminal

boxes are accurately

machined to rectangular

shape, and each of them

and their covers are

closely fitted with plain

flanged joints.

The operating mechanism

for the handle of circuit

breaker interior is secure

and smooth.

The operating rod is

machined to the required

tolerance, and an O-ring

is provided for preventing

water and dust coming

into the joint.

The circuit breakers

interior have automatic

quick break mechanism

for protection of over

current and short-circuit

current. These are the

most suitable for the

switching and protection

of general circuits.

The through pattern units

having terminal boxes an

top and bottom are

supplied as standard.

Alternatively Terminal

Pattern units having a

terminal box at top or

bottom are available for

up to 600A rating in 600A

frame size.

Standard FinishMUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

Breaker Frame (AF) 30 50 60 100 225 400 600

Number of poles 2, 3 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4

Rated

Voltage (V)

AC 600 600 600 600 600 600 600

DC 250 250 250 250 250 250 250

Rated Current (A)

at Ambient Temp. 40°C

5

10

15

20

30

5

10

15

20

30

40

50

60 15

20

30

40

50

60

75

100

100

125

150

175

200

225

250

300

350

400

500

600

Rated

Interrupting

capacity (KA)

220VAC 5 10 10 22 30 42 100

460VAC 2.5 5 5 10 22 30 50

600VAC 1.5 2.5 2.5 5 14 25 35

250VDC 2.5 5 5 5 20 40 40

Enclosure Type SS SS SS SS MS LS EL

Catalog No.ECN

8310

ECN

8311

ECN

8312

ECN

8313

ECN

8314

ECN

8315

ECN

8316

Max. Conduit Size1-1/2"

(42C)

1-1/2"

(42C)

1-1/2"

(42C)

2"

(54C)

3"

(82C)

4"

(104C)

4"

(104C)

Max. Conductor Size (mm2) 14 14 14 38 150 250 150 X 2

Page 157: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Circuit Breaker Box & Motor Starter

EPPC MCCB Box Series

Wet Locations

NEMA 3,3R,4,4X,7

Type of Explosion-proof Flameproof (Ex d IIC T6)

Application

EPPC MCCB Box series are used ;

in heavy process industries having environments where flammable or

explosive vapors or gases, or where combustible dusts are present.

in hazardous areas, both indoors and outdoors where long life and

low maintenance costs are desired.

in petroleum refineries, chemical, petrochemical and other heavy

process industry facilities.

in paint spray booth suitability provides efficient, economical HID

lighting for paint spray areas.

where ignitable concentrations of flammable gases, vapors or liquids

can exist all of the time or some of the time under normal operation

conditions.

in hazardous locations requiring elevated ambient capability.

in installations where moisture, dirt, dust, vibration, corrosion and

rough usage are problems.

Standard Finish DimensionMUNSELL No. 7.5BG 6/1.5

If you want another color, contact us

please.

Frame Size(AF) 100 225

Number of poles 2, 3, 4 2, 3, 4

Rated

Voltage(V)

AC 600 600

DC 250 250

Rated Current(A)

at Ambient Temp. 40°C

15

20

30

40

50

60

75

100

100

125

150

175

200

225

Rated

Interrupting

capacity(KA)

220VAC 22 30

460VAC 10 22

600VAC 5 14

250VDC 5 20

Max. Conduit Size 2"(54C) 3"(82C)

Max. Conductor Size(mm2) 38 150

Page 158: Nb cat

SECTION - 4C

Circuit Breaker Panel Board

Page 159: Nb cat

SECTION 4C

Panel Board INDEX

Model Product Description

Certification for

Explosion-proofpage

IEC

EPBC Instrumentation Panel Board Ex de IIB T6 4C - 1

EPDP Appleton Panel Board Ex d IIC T6 4C - 3

EPDS Rectangular Panel Board Ex d IIB T6 4C - 4

EPFS Stainless steel Panel BoardEx de IIC T6

Ex DP II 124C - 6

EFDS Engineering Plastic Panel BoardEx de IIC T6

Ex de IIB T64C - 8

ETR Transformer for Circuit Breaker Panel Board Ex d IIC T6 4C - 10

EDPT Transformer Ex d IIB T4 4C - 11

Page 160: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Circuit Breaker Panel boards

EPBC Series

Wet Locations

NEMA 3,3R,4,4X,7

Type of Explosion-proof Application

EPBC panel boards are designed specifically for used in ;

Class 1, Division 2, Groups C, D hazardous areas

where flammable vapors or gases may be present

due to accident or abnormal locations.

damp, wet or corrosive locations.

indoors or outdoors in Division 2 areas of

petroleum refineries, chemical and petrochemical

plants, and other process industry facilities.

Flameproof-Increase Safety (Ex de IIB T6)

Features

Enclosures are of external flange

design, which makes the interior

completely accessible when the

cover is removed.

Provided with concealed mounting,

which is made possible by

having our clearance holes for

lag screws or mounting bolts in

the back of the enclosure, one

in each corner.

The interior sub-assembly,

consisting of a mounting plate,

main terminal blocks, branch

circuit terminal blocks and circuit

breakers, is removable as a

complete unit.

Ample gutter space is provided

for ease of field wiring.

Circuit breakers are contained in

compact, individual enclosures

are easily removed and replaced,

therefore changing or adding

individual circuit breakers will not

present a problem.

The main cover, which is

gasketed to exclude dirt and

moisture, is attached to the body

with hex head bolts and is

removed only when installing the

panel-board or making wiring

changes, In the center of the

main cover is a gasketed hinged

door, which provides access

only to the circuit breaker

operating handles, and is held

closed by two quick-release

catches. The door can be locked

by as many as 3 padlocks to

prevent unauthorized operation.

Tapped conduit openings are

provided for main conduit and

branch circuits, as shown in the

dimensional information.

Standard openings can be

reduced or plugged to meet

most installation requirements.

Circuit breakers are arranged in

two vertical rows and have the

circuit numbers marked on the

handles. The left row is

numbered 1, 3, 5, 7, etc. and

the right row 2, 4, 6, 8, etc.

identifying information may be

typed on the circuit directory

card attached to the inside of

the hinged door.

Standard Materials

Body, cover and hinged doors

: Cast aluminium alloy

Interior parts : Sheet steel

Standard FinishMUNSELL No. 7.5BG 6/1.5

If you want another color,

contact us please.

Electrical Rating Ranges

Circuit breakers

Single-pole-120/VAC max.

Two-pole-120/24VAC max.

Trip ratings 15, 20 and 30 Amp.

EPBC Explosion-proof Factory Sealed Panel Board

Panel

Size

No. of

Breaker

Catalog Number

Wiring System No.1

1Phase 2Wire

Wiring System No.2

1Phase 3Wire

Wiring System No.4

3Phase 4Wire

1p 2p 1pole 2pole 1pole 2pole 1pole 2pole

#1

6 EPBC1061 EPBC2061 EPBC4061

8 4 EPBC1081 EPBC1042 EPBC2081 EPBC2042 EPBC4081 EPBC4042

10 5 EPBC1101 EPBC1052 EPBC2101 EPBC2052 EPBC4101 EPBC4052

12 6 EPBC1121 EPBC1062 EPBC2121 EPBC2062 EPBC4121 EPBC4062

#2

14 7 EPBC1141 EPBC1072 EPBC2141 EPBC2072 EPBC4141 EPBC4072

16 8 EPBC1161 EPBC1082 EPBC2161 EPBC2082 EPBC4161 EPBC4082

18 9 EPBC1181 EPBC1092 EPBC2181 EPBC2092 EPBC4181 EPBC4092

20 10 EPBC1201 EPBC1102 EPBC2201 EPBC2102 EPBC4201 EPBC4102

22 11 EPBC1221 EPBC1112 EPBC2221 EPBC2112 EPBC4221 EPBC4112

24 12 EPBC1241 EPBC1122 EPBC2241 EPBC2122 EPBC4241 EPBC4122

#3

13 EPBC1132 EPBC2132 EPBC4132

14 EPBC1142 EPBC2142 EPBC4142

15 EPBC1152 EPBC2152 EPBC4152

16 EPBC1162 EPBC2162 EPBC4162

17 EPBC1172 EPBC2172 EPBC4172

18 EPBC1182 EPBC2182 EPBC4182

#419 EPBC1192 EPBC2192 EPBC4192

20 EPBC1202 EPBC2202 EPBC4202

If you need more information, contact us please. ⇨

Page 161: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Replacement Circuit Breaker Assemblies

Where EPBC panel boards have been ordered with less

than the maximum number of circuit breakers, breakers

can easily be added in the field. Circuit breaker

assemblies for field addition or replacement are listed

below; they consist of the breaker it-self in its factory

sealed Class 1, Division 2, Groups C, D enclosure,

leads for connection to terminal blocks, and necessary

hard-ware.

Ordering Information 1-Pole Circuit Breaker Assemblies Ampere

Panel boards are available with 15, 20 or 30

ampere circuit breakers. To order a panel board

with all breakers of the same ration add the

desired rating as a suffix to the Cat. No. For

example, the 12 circuit EPBC 2512 panel board

with all the circuit breakers rated 20 amperes

would be ordered as EPBC 2512-20.

Panel boards can be furnished with an

assortment of breaker rations. To order, the

quantities and ampere ratings are added as

suffixes to the Cat. No. For example, the 12

circuit EPBC 2512 with six 15 ampere, four 20

ampere and two 30 ampere circuit breakers

would be ordered as EPBC 2512-615-420-230.

The EPBC with a main breaker is available up to

100 amps. To order EPBC with main breaker,

add the appropriate suffix. Example. EPBC

2512-15 with 3 pole, 100 amp main circuit

breaker would be ordered as EPBC 2512-15-3M

100. If 2 pole main is required, change the

number 3 to 2 if a lower trip rating than 100 is

required, the suffix will change accordingly.

Rating

15 EPC11-15

20 EPC11-20

30 EPC11-30

2-Pole Circuit Breaker Assemblies Ampere

Rating

15 EPC11-15

20 EPC11-20

30 EPC11-30

Dimensions (mm)

TYPE A B C D E

#1 572 526 406 582 210

#2 572 718 406 776 210

#3 572 945 406 1003 270

#4 572 1085 406 1143 270

Page 162: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Circuit Breaker Panelboards

EPDP Series

Outdoor use

IEC Code: Ex d IIC

ZONE1 & ZONE2

Type of Explosion-proof Flameproof (Ex d IIC T6)

Application Features

Protection and control of lighting

and power distribution in

classified locations or in damp,

wet, or corrosive conditions.

Designed for use in

manufacturing and processing

areas where ignitable vapors,

gases or highly combustible

dusts are present.

Panel size-accommodate from 6

thru 24 two-pole circuit breaker

spaces as standard. It could be

extended & provided more 24ckts

breakers as selection.

Housing pivots 180° for removal of

breaker cover.

Both junction and breaker compartments

fully gasketed for raintight fit.

No external branch seal fittings

need-ed-factory sealed enclosures.

Each branch circuit breaker is lockable

in ON or OFF position.

Circuit directory card-Clear plastic

cover.

Main feed conduit openings at both top

and bottom of enclosure allow main

feed entry at either center of enclosure.

Canopy(sun shade) is provided as

option.Standard FinishBS4800 Shade 10-A-3

If you want another color,

contact us please.

Breaker Amperage

16 32,63,....max225

Dimensions

<Size 1> <Size 3> <Size 2> <Size 4>

<Size 5>

EPDP Explosion-proof Factory Sealed Panel Board

Panel

Size

No. of

Breaker

Catalog Number

Wiring System No.1

1Phase 2Wire

Wiring System No.2

1Phase 3Wire

Wiring System No.3

3Phase 3Wire

Wiring System No.4

3Phase 4Wire

1p 2p 3p 1pole 2pole 1pole 2pole 2pole 3pole 2pole 3pole

16 EPDP1061 EPDP2061

8 4 2 EPDP1081 EPDP1042 EPDP2081 EPDP2042 EPDP3042 EPDP3023 EPDP4042 EPDP4023

210 5 EPDP1101 EPDP1052 EPDP2101 EPDP2052 EPDP3052 EPDP4052

12 6 3 EPDP1121 EPDP1062 EPDP2121 EPDP2062 EPDP3062 EPDP3033 EPDP4062 EPDP4033

314 7 EPDP1141 EPDP1072 EPDP2141 EPDP2072 EPDP3072 EPDP4072

16 8 4 EPDP1161 EPDP1082 EPDP2161 EPDP2082 EPDP3082 EPDP3043 EPDP4082 EPDP4043

418 9 EPDP1181 EPDP1092 EPDP2181 EPDP2092 EPDP3092 EPDP4092

20 10 6 EPDP1201 EPDP1102 EPDP2201 EPDP2102 EPDP3102 EPDP3063 EPDP4102 EPDP4063

522 11 EPDP1221 EPDP1112 EPDP2221 EPDP2112 EPDP3112 EPDP4112

24 12 8 EPDP1241 EPDP1122 EPDP2241 EPDP2122 EPDP3122 EPDP3083 EPDP4122 EPDP4083

614 EPDP1142 EPDP2142 EPDP3142 EPDP4142

16 10 EPDP1162 EPDP2162 EPDP3162 EPDP3103 EPDP4162 EPDP4103

718 EPDP1182 EPDP2182 EPDP3182 EPDP4182

20 12 EPDP1202 EPDP2202 EPDP3202 EPDP3123 EPDP4202 EPDP4123

822 14 EPDP1222 EPDP2222 EPDP3222 EPDP3143 EPDP4222 EPDP4143

24 16 EPDP1242 EPDP2242 EPDP3242 EPDP3163 EPDP4242 EPDP4163

Page 163: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Circuit Breaker Panel Board

EPDS Series

Wet Locations

NEMA 3,3R,4,4X,7

Type of Explosion-proof Flameproof (Ex d IIB T6)

Features

In each housing the cover is fitted the body

with cylindrical joint for highly reliable

flameproof and weatherproof properly. The

breaker housings and separable from busbar

housing by the flameproof packing type seal.

Both built-in breaker and the operating handle

are installed on the cover. They can be pulled

out together with the cover by releasing four

fixing bolts for maintenance.

Busbar housing contains the bus bars and

leads, and provides terminal at the lower end.

Application Standard Materials Standard Finish

This range of EPDS panel

boards is designed for high

degree of flameproof protection,

good weatherproofness, and

easy installation and

maintenance.

These are constructed and

assembled with breaker

housings, busbar housing and a

branch terminal housing in

accordance with the number of

branch circuits.

Breaker Housing :

Cast aluminium alloy

Main & Branch Bus Bar Housing

: Cast aluminium alloy

Terminal Box :

Cast aluminium alloy

Mounting Frame : Steel

MUNSELL No. 7.5BG 6/1.5

If you want another color,

contact us please.

Details of Breakers

Description Circuit Breaker Motor Breaker

Frame Size 50A 50A

No.of Poles 2 | 3 3

Rated Voltage 400/440V AC 400/440V AC

Rated Current 5, 10, 15, 20 or 30A 15KW Max.

Rated Interrupting 5KA at 460V AC 5KA at 460V AC

The EPDS with a main breaker is available up to 225 amps. To order EPDS with main breaker, add the appropriate

suffix. Example: EPDS 2122-20 with 3pole, 100Amp main circuit breaker would be ordered as EPDS

2122-20-3M100. If 2pole main is required change the number 3 to 2. If a other trip rating then 100 is required, the

suffix will change accordingly.

Page 164: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Flameproof EPDS Panel Boards

Panel

Size

No. of

Breaker

Catalog Number

Wiring System No.1

1Phase 2Wire

Wiring System No.2

1Phase 3Wire

Wiring System No.3

3Phase 3Wire

Wiring System No.4

3Phase 4Wire

1pole 2pole 1pole 2pole 2pole 3pole 2pole 3pole

1 4 EPDS 1041 EPDS 1042 EPDP 2041 EPDP 2042 EPDP 3042 EPDP 3043 EPDP 4042 EPDP 4043

2 6 EPDS 1061 EPDS 1062 EPDP 2061 EPDP 2062 EPDP 3062 EPDP 3063 EPDP 4062 EPDP 4063

3 8 EPDS 1081 EPDS 1082 EPDP 2081 EPDP 2082 EPDP 3082 EPDP 3083 EPDP 4082 EPDP 4083

4 10 EPDS 1101 EPDS 1102 EPDP 2101 EPDP 2102 EPDP 3102 EPDP 3103 EPDP 4102 EPDP 4103

5,2 12 EPDS 1121 EPDS 1122 EPDP 2121 EPDP 2122 EPDP 3122 EPDP 3123 EPDP 4122 EPDP 4123

2 14 EPDS 1141 EPDS 1142 EPDP 2141 EPDP 2142 EPDP 3142 EPDP 3143 EPDP 4142 EPDP 4143

3 16 EPDS 1161 EPDS 1162 EPDP 2161 EPDP 2162 EPDP 3162 EPDP 3163 EPDP 4162 EPDP 4163

3 18 EPDS 1181 EPDS 1182 EPDP 2181 EPDP 2182 EPDP 3182 EPDP 3183 EPDP 4182 EPDP 4183

4 20 EPDS 1201 EPDS 1202 EPDP 2201 EPDP 2202 EPDP 3202 EPDP 3203 EPDP 4202 EPDP 4203

4 22 EPDS 1221 EPDS 1222 EPDP 2221 EPDP 2222 EPDP 3222 EPDP 3223 EPDP 4222 EPDP 4223

5 24 EPDS 1241 EPDS 1242 EPDP 2241 EPDP 2242 EPDP 3242 EPDP 3243 EPDP 4242 EPDP 4243

PANEL SIZEA TYPE (2P MCCB) B TYPE (3P MCCB)

H1 H2 H3 H4 H1 H2 H3 H4

1 705 755 145 280 860 910 194 378

2 840 890 145 280 1040 1090 194 378

3 985 1035 145 280 1240 1290 194 378

4 1120 1170 145 280 1420 1470 194 378

5 1265 1315 145 280 1620 1670 194 378

APPLICATION Branch 1-POLE, MCCB

Branch 3-POLE, MCCB

2-POLE, MCCB ELCB

Dimensions

Page 165: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Circuit Breaker Panel Board

EPFS Series

Wet Locations

Factory Sealed

NEMA 3,4,4X,7,9

<EPFS W 3063 - DBSC>

Breaker

Enclosure

Type of Explosion-proof Flameproof-Increase Safety (Ex de IIC T6)

Dust Ignition-proof (Ex DP II 12)

Application

EPFS Series panel boards are used ;

in locations which are hazardous due to the

presence of flammable vapors or gases and where

dampness or corrosion are present.

for indoor and outdoor applications in petroleum

refineries, chemical and petrochemical plants, and

other process industry facilities where similar hazards

exist.

Features

Factory sealed - no external seal required.

Fully wired from circuit breaker housing to

pre-numbered terminals in wiring compartment.

Stainless steel construction provides excellent

resistance to corrosion.

Circuit breakers are contained in compact, individual

factory sealed enclosured suitable for flameproof

hazardous location.

Two inner wiring type - Bus Bar type, Wire type.

Silicone cover gasket provides a watertight seal to

meet IP65.

Standard is IP65, but IP66 can order made.

Standard Materials Compliance Standard Finish

Enclosure : Stainless steel

Interior parts : Aluminum alloy

IEC 60079-0, 1, 7

NEMA 3, 4, 4X, 7, 9

Natural

If you want another color,

contact us please.

Options Certification

Drain and breather

Grounded neutral lug

Sunshade cover

Can use cable gland instead of

coupling

Test button with ELB

Certified by KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas Safety

Corporation), and the others.

Technical DataElectrical Rating

Main Breaker Max. 600V / 225AF / 225AT / 4P

Branch Breaker Max. 600V / 100AF / 100AT / 3P

Entry Size Max. 2-1/2" - 6EA

If you need more information, contact us please. ⇨

Page 166: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Ordering Number

Panel

Size

Wire Type Bus Bar Type Dimension

Max. No

of Breaker

3 phase 3 wire Max. No

of Breaker

3 phase 3 wire (mm)

2 pole 3 pole 2 pole 3 pole A B C

A 18 EPFS W 3182 EPFS W 3183 14 EPFS B 3142 EPFS B 3143 1500 950 230

B 12 EPFS W 3122 EPFS W 3123 10 EPFS B 3102 EPFS B 3103 1200 950 230

C 8 EPFS W 3082 EPFS W 3083 - - - 1200 700 230

D 6 EPFS W 3062 EPFS W 3063 - - - 1200 550 230

Ordering Information

When ordering refer to below and contact us

please

Quantity of breakers in wire type panel board is

with terminal block and in bus-bar type panel

board is without terminal block.

Panel board size are only use NAMBUK

standard breakers. If you want use other size

breaker, contact us please.

Standard Breaker is Main Breaker : MCCB

50AF/100AF/225AF Branch Breaker : ELCB

50AF/100AF

EPFS Series can install Max. two main breaker

(Standard is one main breaker)

Ordering with specify position and size of

conduit entries (Max. 2-1/2" 6EA)

Ordering with quantity and amperes of branch

breakers

E P F S B 3 0 4 2 - 5 0 - S N DB ① ② ③ ④ ⑤ ⑥ ⑦

EPFS Panel Board① Quantity of Breakers④

04 - 4 Circuit

18 - 18 Circuit

Inner Wiring Type②

B - Bus Bar No. of Breaker Poles⑤

W - Wire 2 -2 Pole / 3 -3 Pole

Amp. of Main Breaker⑥

Wiring System No.③ 50 - 50A / 225 - 225A

2 - 1 phase 3 wire

3 - 3 phase 3 wire Option⑦

4 - 3 phase 4 wire SN - Solid Neutral Lug

DB - Drain & Breather

SC - Sunshade cover

Dimension Inner Wire Type

<Wire Type>

<Bus Bar Type>

Page 167: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2005

Circuit Breaker Panel Board

EFDS Series

Wet Locations

Factory Sealed

NEMA 3,4,4X,7,9

<Factory Sealed Breaker>

Type of Explosion-proof Flameproof-Increase safety (Ex de IIC T6)

Application

EFDS Series panel boards are used ;

in locations which are hazardous due to the

presence of flammable vapors or gases and where

dampness or corrosion are present.

for indoor and outdoor applications in petroleum

refineries, chemical and petrochemical plants, and

other process industry facilities where similar hazards

exist.

Features

Factory sealed - no external seal required.

Fully wired from circuit breaker housing to

pre-numbered terminals in wiring compartment.

Eng. plastic construction provides excellent

resistance to corrosion.

Circuit breakers are contained in compact, individual

factory sealed enclosured suitable for flameproof

hazardous location.

Standard circuit breaker housing material is glass

fiber reinforced polyester. (Cast Al circuit breaker is

order made)

Silicone cover gasket provides a watertight seal to

meet IP66.

Standard Materials Compliance Standard Finish

Main Enclosure : Glass fiber

reinforced polyester

Circuit Breaker : Glass fiber

reinforced polyester

IEC 60079-0, 1, 7

NEMA 3, 4, 4X, 7, 9Enclosure - Dark Gray

Breaker - Black

Certification

Certified by KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas Safety

Corporation), and the others.Technical Data

Electrical Rating

Main Breaker Max. 600V / 225AF / 225AT / 4P

Branch Breaker

Max. 600V / 100AF / 100AT / 3PStandard circuit is Max. 24 Circuit.

Left breakers are standard.

If you want more circuit or another type

breaker, contact us please.

Max. 600V / 50AF / 50AT / 3P

Max. 600V / 63AT / 4P

Max. 600V / FR 50AF / 50AT / 2P

Max. 600V / 63AF / 63AT / 2P

Entry Size Max. 3" - 2EA / Box

If you need more information, contact us please. ⇨

Page 168: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2005

Ordering Information

When ordering refer to below and contact us

please

Quantity of breakers are Max. 24 circuit. If you

want more circuit, contact us.

Standard breaker is

Main Breaker : MCCB 50AF/100AF/225AF

Branch Breaker : ELCB 50AF/100AF/63AF

EFDS Series can install multi main breaker

(Standard is one main breaker)

Ordering with specify position and size of

conduit entries (Max. 3" - 2EA)

Ordering with quantity and amperes of branch

breakers

E F D S 3 2 4 3 - 5 0 ① ② ③ ④ ⑤

EFDS Panel Board① No. of Breaker Poles④

1 - 1 Pole

Wiring System No.② 2 - 2 Pole

1 - 1 phase 2 wire 3 - 3 Pole

2 - 1 phase 3 wire 4 - 4 Pole

3 - 3 phase 3 wire

4 - 3 phase 4 wire Amp. of Main Breaker ⑤

50 - 50A

Quantity of Breakers③ 100 - 100A

04 - 4 Circuit 225 - 225A

24 - 24 Circuit

Inner of EFDS

< Inner of EFDS Panel > <Breaker Part> <Busbar Part>

Reference Dimension

Page 169: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Transformer for Circuit Breaker Panelboards

ETR Series

Wet Locations

NEMA 3,3R,4,4X,7

Type of Explosion-proof Flameproof (Ex d IIC T6(H2) IP55)

Application Features

EPDS Circuit Breaker Panelboard

assemblies with ETR Transformers

are for use;

indoors or outdoors in Zone 1

areas such as petroleum

refineries, chemical and

petrochemical plants, and other

process industry facilities

where high voltage supply must

be stepped down to the lower

voltage necessary to serve

lighting, heating, appliance, heat

tracing, motor and similar circuit

For general information on

panelboard applications, circuit

breakers and wiring systems, refer

to catalog section 4C.

The factory assembled panelboard and

transformer are on one compact frame,

suitable for either wall or pole mounting.

Wiring between the transformer

secondary and main lugs of the

panelboard id accomplished at the

factory.

Easy to install and wire. The main feed

is connected to the transformer primary

and the branch circuits are wired to the

panelboard terminal blocks.

Transformers are compound filled or

epoxy filled to completely seal out

moisture and dirt.

The assembly can be installed in the

load area to reduce the length of runs

of low voltage branch circuits.

Standard Materials Ordering Check ListEnclosure : Sheet Steel 1. Select the EPDS Circuit breaker panelboard required, together with any

applicable options or special features.

2. Provide the following information, necessary for selection of the correct

transformer.

- Primary voltage

- Secondary voltage

- KVA rating

- Taps - number and percent

- Frequency (Standard is 60Hz)

- Single or three-phase

- Other requirement

Size RangeTransformer

Single or three phase

5KVA to 30KVAPanelboard

Standard is 12 circuit (3p)

If you want more circuit, contact

us.

Electrical RatingPrimary - 480V

Secondary - 120/ 240V

Dimensions

Page 170: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Step-down Transformers

EDPT Series

Wet Locations

NEMA 3, 3R, 4, 4X, 7

Type of Explosion-proof

Flameproof (Ex d IIB T4)

<Single Type>

<Twin Type>

Standard Materials Selection Table of Rubber Packings for Cable Enteries

Main Body : Cast Aluminum alloy

Switched Socket Housing :

Die-casting aluminum

Plug Casing : Die-casting aluminium

Base : Steel

Packing No.

Nominal Diameter of Cable

Suitable Chloroprene Sheathed Portable Power Cable, Class 3

Incoming

Cable

Gland

28-18 16 to 18 mm 3 core 2.0 mm2

28-20 16 to 20 mm 3 core 3.5 mm2

28-21 20 to 21 mm 3 core 5.5 mm2

28-22 21 to 22 mm 3 core 8 mm2

Standard Finish

Output

Plugs

15S 13 to 15 mmMUNSELL No. 7.5BG 6/1.5

If you want another color, contact us

please.

16S 15 to 16 mm 3 core 0.75 mm2

17S 16.5 to 17 mm 3 core 2.0 mm2

Unless otherwise stated the transformers are supplied with No. 28-20 packing for incoming cable gland and with No 17S packing for output plugs.3 core 0.75mm2 Chloroprene Sheathed Portable Power Cable can be supplied in cut lengths to suit customers' requirement.

Rating / Catalog No.

No. of Sockets

Capacity(VA)

Socket

Rating

Secondary

Current(A)Primary

Voltage(V)Secondary Voltage(V)

Catalog No.Weight

(kg)

Conduit Entry

(Single Socket)

- Terminal

28 (1") max.

Specify the

size ordering.

Single 200 15A

250V

2P+E

5100

200

24 EDPT 5119

24 EDPT 521

Twin 250 5 X 2100

200

24 EDPT 51220

24 EDPT 522

Application Features EDPT transformer units are primarily designed for supplying safety low voltages to small appliances such as handlamp. These units are provided with switched socket outlets and plugs to which the appliances are to be connected.

The body, both single socket and twin socket types, is cast in one piece, comprising the main enclosure and a terminal chamber with barrier wall between. The socket outlets are provided on the cover of the enclosure. The cover mountings of the single socket unit are spigot joint with O-ring for main enclosure and threaded joint with O-ring for terminal chamber. Those of the twin socket unit are flanged joint for main enclosure and spigot joint with O-ring for terminal chamber.Replacement of fuse link can be made by removal of the cover of main enclosure for the single socket unit, and by removal of the exclusive screw-on cover for the twin socket unit

Page 171: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2005

Circuit Breaker Panel Board

EFDS Series

Wet Locations

Factory Sealed

NEMA 3,4,4X,7,9

<Factory Sealed Breaker>

Type of Explosion-proof Flameproof-Increase safety (Ex de IIC T6)

Application

EFDS Series panel boards are used ;

in locations which are hazardous due to the

presence of flammable vapors or gases and where

dampness or corrosion are present.

for indoor and outdoor applications in petroleum

refineries, chemical and petrochemical plants, and

other process industry facilities where similar hazards

exist.

Features

Factory sealed - no external seal required.

Fully wired from circuit breaker housing to

pre-numbered terminals in wiring compartment.

Eng. plastic construction provides excellent

resistance to corrosion.

Circuit breakers are contained in compact, individual

factory sealed enclosured suitable for flameproof

hazardous location.

Standard circuit breaker housing material is glass

fiber reinforced polyester. (Cast Al circuit breaker is

order made)

Silicone cover gasket provides a watertight seal to

meet IP66.

Standard Materials Compliance Standard Finish

Main Enclosure : Glass fiber

reinforced polyester

Circuit Breaker : Glass fiber

reinforced polyester

IEC 60079-0, 1, 7

NEMA 3, 4, 4X, 7, 9Enclosure - Dark Gray

Breaker - Black

Certification

Certified by KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas Safety

Corporation), and the others.Technical Data

Electrical Rating

Main Breaker Max. 600V / 225AF / 225AT / 4P

Branch Breaker

Max. 600V / 100AF / 100AT / 3PStandard circuit is Max. 24 Circuit.

Left breakers are standard.

If you want more circuit or another type

breaker, contact us please.

Max. 600V / 50AF / 50AT / 3P

Max. 600V / 63AT / 4P

Max. 600V / FR 50AF / 50AT / 2P

Max. 600V / 63AF / 63AT / 2P

Entry Size Max. 3" - 2EA / Box

If you need more information, contact us please. ⇨

Page 172: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2005

Ordering Information

When ordering refer to below and contact us

please

Quantity of breakers are Max. 24 circuit. If you

want more circuit, contact us.

Standard breaker is

Main Breaker : MCCB 50AF/100AF/225AF

Branch Breaker : ELCB 50AF/100AF/63AF

EFDS Series can install multi main breaker

(Standard is one main breaker)

Ordering with specify position and size of

conduit entries (Max. 3" - 2EA)

Ordering with quantity and amperes of branch

breakers

E F D S 3 2 4 3 - 5 0 ① ② ③ ④ ⑤

EFDS Panel Board① No. of Breaker Poles④

1 - 1 Pole

Wiring System No.② 2 - 2 Pole

1 - 1 phase 2 wire 3 - 3 Pole

2 - 1 phase 3 wire 4 - 4 Pole

3 - 3 phase 3 wire

4 - 3 phase 4 wire Amp. of Main Breaker ⑤

50 - 50A

Quantity of Breakers③ 100 - 100A

04 - 4 Circuit 225 - 225A

24 - 24 Circuit

Inner of EFDS

< Inner of EFDS Panel > <Breaker Part> <Busbar Part>

Reference Dimension

Page 173: Nb cat

SECTION - 5C

Grounding Indicator &

Cable Reel

Page 174: Nb cat

SECTION 5C

Ground Indicator & Cable Reel INDEXModel Product Description

Certification for

Explosion-proofpage

EGI Grounding Indicator Ex ibd IIB T6 5C - 1

CRA Cable Reel Ex d IIB T6 5C - 2

Page 175: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Page 176: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Ground Indicator

EGI SeriesNEMA 3, 3R, 4, 4X, 7

Type of Explosion-proof Flameproof (Ex ibd IIB T6)

< EGI 102 >

Application EGI Series are connected to tank vehicles, drums or other portable containers before beginning transfer of combustible materials to :

safely ground static electricity preventing build up of a static charge during pumpingindicate the presence of safe static grounding before and during loading or unloading operationsactuate remote devices (lights, buzzer) to verify completion or interruption of the static groundshut down pumps automatically if the EGI grounding circuit is broken

CautionsPlease this product installs and uses only dangerous location by explosion-proof rule because of Flameproof Enclosure construction.Necessary check whether it was completely joined screw combine part of apparatus.Necessary cut off source when apparatus opens for install, maintain and don't supply the source when apparatus is open.Remove dust or other matter for not happened gap at joint part when opens or closes apparatus and completely screw with tools without hole when screws bolt. Features

1/2" conduit hub for clampTwo pilot lights by LEDColor of Pilot lights makes up red and greenFlameproof Enclosure constructionHeavy duty clamp for static ground connectionStandard Cable length : 10m(If you need another length, contact us please.)

Catalog NumberUnit Catalog No.

Two pilot light EGI 101

Two pilot light/ Buzzer/ Switch EGI 102

Dimension

< EGI 102 > < EGI 101 >

OperationsWhen connected to a truck prior to loading or unloading, the presence of a safe ground is indicated by a green light and the absence of ground is indicated by a red light and a buzzer.Interlocking circuitry will prevent pumps from starting until a ground is established or shut pumps down if a ground is lost at any time during loading or unloading.

Electrical Rating Ranges Source -220V AC, 60Hz Control Relay - DC 12V, DC 6V, 3A Cable - CTF 2C×3.5SQ

Standard Materials Housing Cast Aluminium Alloy Clamp - Engineering Plastic or Cast

Aluminium

Standard FinishMUNSELL No. 7.5BG 6/1.5If you want another color, contact us please.

Page 177: Nb cat

Control

Copyright by NAMBUK Electric Co., LTD. 2004

Auto Cable Reel

CRA Series NEMA 3, 3R, 4, 4X, 7

Type of Explosion-proof

Flameproof (Ex d IIB T6)

Application

CRA Series Cable Reels are used ;

in be available to use Grounding Indicator

and Hand Lamp in NAMBUK.

in designed for lift, pick-up and suspension

applications in hazardous location containing

flammable vapors, gases or combustible

dust.

in transfers safe, uninterrupted power or

control signals for equipment requiring 3.5㎟

to 5.5 Type SO oil-resistant cable with 2 ㎟

to 3 conductors.

< CRA >

Standard Materials Features

Steel frame and reel sides

Brushes are high-density copper-graphite

Collector rings are copper

Compact size, light weight and rugged

construction for long service with minimum

maintenance.

Fast and easy installation.

Safety ground through separate collector ring

and frame provides positive grounding path.

Lifetime-lubricated bearings reduce

maintenance.

Easy-to-remove cover provides quick access

to springs.

Built-in cable locking ratchet is provided with

reel and can be easily activated when

required.

For longer cable length applications.

Compliance & Certification

IEC 60079-0, 1

Certified by KOSHA (Korea Occupational Safety & Health

Agency), KGS (Korea Gas Safety Corporation), and the

others.

Standard Finish

Baked on Epoxy Powder - 7.5BG 6/1.5 8N-7

If you want another color, contact us please.

Technical Data

Cat. No. CRA 1 CRA 2 CRA 3

Outlet Available

TypeFour Roller Swivel Type Two Roller

Max Bending

Degree60° 225° 180° Dimension

Ca

ble

Conductors SO Type 2 to 3 conductors

Size 3.5 to 5.5 ㎟

Length 10 m (standard)

Suffix GR for grounding indicator.※

Cable Length is available to be adjusted in accordance ※

with your order.

Ordering Information

These Reels are shipped with ratchets which are "locked

out" for constant cable tension. These ratchets can be

easily field-activated where cable locking is desired.

If you need more information, contact us please. ⇨

Page 178: Nb cat

SECTION - 1P

Plug & Receptacle

Page 179: Nb cat

SECTION 1P

Plug & Receptacle INDEXModel Product Description

Certification for

Explosion-proofPage

VWPR VWPR 15A, 20A Weatherproof Type 1P - 1

VPR VPR 30A, 60A, 100A Weatherproof Type 1P - 2

EUPR EUPR 20A Ex d IIB T6 1P - 3

EDPR EDPR 60A Weather proof Type 1P - 4

EPR EPR 20A, 30A, 100A Ex de IIB T6 1P - 5

EPRH EPRH 20A, 100AEx de IIC T6 IP55

Ex de IIC T61P - 9

Page 180: Nb cat

Plug & Receptacle

Copyright by NAMBUK Electric Co., LTD. 2004

Plugs And Receptacles

VWPR SeriesWeatherproof Type

<VWP> <VWR>

Dimension

Application Standard Materials

VWP Plugs and VWR Receptacles are used ;

wherever dust, dirt, moisture and corrosion are a

problem.

outdoor or in locations where frequent

washdowns occur, as in dairies and food

processing plant.

Receptacle : Cast aluminium alloy

Cap : Cast aluminium alloy

Device Box : Cast aluminium alloy

Electrical Rating Ranges

15 Amperes

20 AmperesFeatures

VWR receptacle housing are used :

with cast device boxes, either surface mounted or

installed flush in a wall.

with single gang, two gang tandem and multiple

gang boxes having individual cover openings.

A threaded cap which effectively seal housing

when not use.

VWP Plugs included :

A molded Neoprene hood with integral sleeve to

seal the cord entrance

A aluminum ring which clamps the hood to

receptacle housing face, to complete watertight

seal when plug is in use.

VWR Receptacles and VWP Plugs

RatingCover with

Recept. Cat #Style Plug Cat # Cord Dia.

15 Amp.

125 VoltsVWR-1512

2 Wire

3 PoleVWP-1512 1.27~15.8

15 Amp.

250 VoltsVWR-1525

2 Wire

3 PoleVWP-1525 1.27~15.8

20 Amp.

125 VoltsVWR-2012

2 Wire

3 PoleVWP-2012 1.27~15.8

20 Amp.

250 VoltsVWR-2025

2 Wire

3 PoleVWP-2025 1.27~15.8

Standard FinishMUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

Page 181: Nb cat

Plug & Receptacle

Copyright by NAMBUK Electric Co., LTD. 2004

Plugs And Receptacles

VPR SeriesWeatherproof Type

< VPR > < VPP >

Dimension

<VPR 30A>

<VPR 60A>

Application Heavy Duty & Weatherproof VPR Receptacles & VPJ Plugs

Circuit breaking plugs and receptacles are used :

to supply power to portable electrically

operated devices such as motor-generator

sets, compressors, heating and cooling units,

weldes, conveyors, lighting systems and

similar equipment

where temporary power is needed, such as at

trailers, building units, heavy machinery and

similar equipment

wherever electrical loads must be quickly

disconnected from power source

in Indoors and outdoors in non-hazardous

areas of chemical plants, process industry

facilities, meat packing plants, manufacturing

plants and similar industrial locations

Receptacle Plug

Hub Size Cat No. Cable Dia Cat No.

30A

~

480VAC

3 Wire

3Pole

3/4"(22C) VPR-3133 13.0 to 17.8 VPP-3133

1"(28C) VPR-3233 17.8 to 21.6 VPP-3233

3 Wire

4 Pole

3/4"(22C) VPR-3134 13.0 to 17.8 VPP-3134

1"(28C) VPR-3234 17.8 to 21.6 VPP-3234

60A

~

480VAC

3 Wire

3Pole

1"(28C) VPR-6133 19.1 to 27.2 VPP-6133

1-1/4"(36C) VPR-6233 27.2 to 34.3 VPP-6233

3 Wire

4 Pole

1"(28C) VPR-6134 19.1 to 27.2 VPP-6134

1-1/4"(36C) VPR-6234 27.2 to 34.3 VPP-6234

100A

~

480VAC

3 Wire

3Pole

1-1/2"(42C) VPR-10133 24.1 to 34.8 VPP-10133

2"(54C) VPR-10233 34.7 to 38.1 VPP-10233

3 Wire

4 Pole

1-1/2"(42C) VPR-10134 24.1 to 34.8 VPP-10134

2"(54C) VPR-10234 34.7 to 38.1 VPP-10234

Standard Materials

Switch receptacle Housing :

Cast aluminium alloy

Plug and Receptacle's Back Box :

Cast aluminium alloy

Dimension

<VPR 3020>

Standard FinishMUNSELL No. 7.5BG 6/1.5

If you want another color, contact us

please.

Page 182: Nb cat

Plug & Receptacle

Copyright by NAMBUK Electric Co., LTD. 2004

Plugs And Receptacles

EUPR SeriesNEMA 3, 3R

Type of Explosion-proof Flameproof (Ex d IIB T6)

< EUPR >

Application

EUR receptacles and EUP plugs are used :

with portable electrically operated devices such as

motor-generator sets, compressors, conveyors, portable tools,

lighting systems and similar equipment.

in locations which are hazardous due to the presence of

flammable vapors or gases.

in damp or corrosive locations

in petroleum refineries, chemical and petrochemical plants, and

other process industry facilities where similar hazards exist.

Dimension(mm) Features

The delayed action feature permits the plug to be

used as an emergency pushpull switch.

EUR receptacles are equipped with a rotating

mechanism which prevents complete withdrawal of

the EUP plug in one continuous movement.

The receptacles are factory sealed to simplify

installation and wiring-external seals are not

required.

The receptacles have top hinged cover design, with

45° downward angled receptacle housing, to provide

superior environmental protection from

accumulations of dust, show , ice and water.

The plug withdrawn until it is stopped by the

delayed action mechanism. In this position the

circuit has been broken and the arc has been

snuffed in the contact chambers.

To completely withdraw the plug, the delayed action

release lever must be rotated counterclockwise.

When inserting the plug, the reverse procedure is

followed.

Standard Materials

Receptacle housings : Die casting aluminium

Plug housings : Die casting aluminium

Back boxes : Cast aluminium alloy

Insulation : Fiberglass reinforced polyester

EUP Explosion proof Plugs Standard Finish Rating Poles Cable Diameter Cat NO.

MUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.20 Amp.2 Wire

3 Pole

8 to 11 EUP 2011

9.5 to 12.7 EUP 2013

12.7 to 16 EUP 2016

Grounding EUR Explosion proof Factory sealed Circuit Breaking Receptacles

Receptacles and plugs

are provided with an

extra grounding pole.

In plugs, provision is

made for attachment

of the grounding wire

to the plug housing.

Rating Style Description Thread SizeCatalog Number

Single Gang Two Gang Three Gang

20Amp.

125-240VAC

18VDC

2 Wire

3 Pole

Dead

End

1/2"(16C) EUR 2011 EUR 2021 EUR 2031

3/4"(22C) EUR 2012 EUR 2022 EUR 2032

1"(28C) EUR 2013 EUR 2023 EUR 2033

Through

Feed

1/2"(16C) EURC 2011 EURC 2021 EURC 2031

3/4"(22C) EURC 2012 EURC 2022 EURC 2032

1"(28C) EURC 2013 EURC 2023 EURC 2033

Page 183: Nb cat

Plug & Receptacle

Copyright by NAMBUK Electric Co., LTD. 2004

Plugs And Receptacles

EDPR SeriesWeatherproof

<EDR>

<EDP>

Explosion-proof Back Box

Style

#1

28

1"

Style

#2

36

1-1/4"

Application

EDR Receptacles and EDP Plugs are

used ;

with portable electrically operated

devices such as motor generator

sets, compressors, conveyors,

portable tools, lighting systems and

similar equipment

in locations which are hazardous due

to the presence of combustible dusts

occuring in the processing and

handling of grain, flour and starch

in the 60 ampere, assemblies are

also suitable for use in areas which

are hazardous due to the presence

of flammable vapors or gases, as in

petroleum refineries, chemical and

petrochemical plants, and certain

process industry facilities.

Style

#3

42

1-1/2"

Explosion-proof Plug and Receptacle with Black

RatingNo. of

PoleHub Size

Recept.

Cat. No.

Nominal

Diameter

Of Cable

Plug

Cat. No

EDRB Recept.

With Back Box

Cat. No.

60A

220VAC

3wire

4pole

28 1"

EDR 1261

16 to 21 EDP 1261

EDRB 126136 1-1/4" 19 to 27 EDP 1262

42 1-1/2" 27 to 34 EDP 1263

60A

460VAC

3wire

4pole

28 1"

EDR 1461

16 to 21 EDP 1461

EDRB 146136 1-1/4" 19 to 27 EDP 1462

42 1-1/2" 27 to 34 EDP 1463

Dimension(mm)

EDR

EDP

Standard Materials

Back Boxes : Cast aluminium alloy

Receptacle housings And plug

exteriors : Cast aluminium alloy

Standard FinishMUNSELL No. 7.5BG 6/1.5

If you want another color, contact us

please.

Features

Construction of the receptacle permits the plug to be used as an emergency push-pull switch.EDR dead front receptacles are equipped with two separate contact assemblies. The rear contact assembly, to which field connections are made, is factory sealed to the housing. The movable front contact assembly, by virtur of its construction, provides an effective dust seal and, in the case of the 60 ampere unit a flametight joint as well.In operation, the plug must first be fully engaged with the front contact assembly, The plug may then be rotated clockwise and moved to engage the rear contact assembly.The plug cannot be withdrawn until the front contact assembly has been disengaged from the rear assembly and rotated counterclockwise to return it to the starting position.With this construction and operating sequence, the circuit making and breaking contacts are enclosed within a separate chamber, effectively sealed at both ends. Ignition of dust or flammable vapors or gases is prevented.The 30 and 60 ampere receptacles are provided with pressure terminals for field connection.As shown in the listings and dimensions, a selection of back boxes is offered to meet varied installation requirements.

Page 184: Nb cat

Plug & Receptacle

Copyright by NAMBUK Electric Co., LTD. 2004

Plugs And Receptacles

EPR 20A Wet Locations

Type of Explosion-proof DimensionFlameproof-Increase Safety

(Ex de IIB T6)

< EPR 20A >

Conduit Size h

16(1/2") 17

22(3/4") 20

28(1") 23

Flameproof EPR Plugs and Receptacles Standard Materials

Switch Receptacle

Housing : Die casting aluminium

Terminal Box : Die casting aluminium

Plug Casing : Die casting aluminium

Conduit Entry Catalog No. Weight(Kg)Position Size

Terminal16(1/2") EPR 1011

4

22(3/4") EPR 101228(1") EPR 1013

Through-way16(1/2") EPR 1014

Specification22(3/4") EPR 101528(1") EPR 1016 Rated Voltage 250V AC

Rated Current 15-20A

Number of Pins 3 (2Pole+Earth)

* If you want 2 Gang, add suffix "2" to Cat. No. Example : EPR1011-2

Features

The flameproof enclosures of the switched receptacle are composed of the main body, barrier and terminal box,

putting one on another with spigot joints.

The interlocking device is of plug operation type. the built_in switch can only be operated by the plug in fully

engaged position, and the plug cannot be withdrawn unless the switch is in open position.

The plug is compact and complete flameproof, and incorporates a flameproof packing type cable gland.

The blanking cap is of spring-operated type and covers the receptacle outlet automatically when the plug is

withdrawn.

Selection Table of Rubber Packings for Cable Enteries*3 core 0.75mm222 Chloroprene

Sheathed Potable Power Cable can

be supplied in cut lengths to suit

customers' requirement

Packing No.Nominal Diameter

of Cable

Suitable Chlorprene Sheathed Portable

power Cable, Class 3

15S 13 to 15mm

16S 15 to 16mm 3 core 0.75 mm222

17S 16.5 to 17mm 3 core 2.0 mm222

These are the combinations of 15, 20Amperes rating

flameproof plugs and switched receptacles. Which contain

a toggle type switch. These plugs and receptacles are

designed mainly for connecting handlamps and other

portable small appliances to stationary supply-points.

The connector has three pins, but one pin is for earthing,

and these units are used only for single phase load.

Standard FinishMUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

Page 185: Nb cat

Plugs & Receptacle

Copyright by NAMBUK Electric Co., LTD. 2004

Plugs And Receptacles

EPR 30AWet Locations

Type of Explosion-proof

Flameproof-Increase Safety (Ex de IIB T6)

< EPR 30A (30 Type) >

Dimension(mm)

Selection Table of Rubber Packings for Cable Enteries Specification

Packing No.Nominal Diameter

of Cable

Suitable Chloroprene Sheathed Portable Power

Cable, Class 3

Rated Voltage 220V AC 460V ACRated Current 30A 30A

Number of Pins3(2-Pole+Earth) or

4(3-Pole+Earth)4(3-Pole+Earth)28-18 16 to 18mm 3 core 2.0mm222

Rated Interrupting

Capacity5KA at 220V AC 2.5KA at 460V AC28-20 18 to 20mm

3 core 3.5mm2 2 2

4 core 2.0mm222

28-21 20 to 21mm3 core 5.5mm2 2 2

4 core 3.5mm222Standard Materials

Switched Socket Housing : cast aluminium alloy

Terminal Box : cast aluminium alloy

Plug Casing : cast aluminium alloy

28-22 21 to 22mm3 core 8 mm2 2 2

4 core 5.5mm222

+Unless otherwise stated plugs are supplied with No. 28-21 packing

Standard FinishMUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

Flameproof EPR Plugs and Receptacles with Circuit Breaker 30 Amps

Rated Voltage(V)

Conduit Entry Catalog No. Weight(Kg) *For EPR 3027

(460 volts

rating), specify

position and

size of conduit

entries when

ordering.

Position Size 3-Pin 4-Pin

220

Top22(3/4") EPR 3011 EPR 3021

9.228(1") EPR 3012 EPR 3022

Bottom22(3/4") EPR 3013 EPR 3023

9.228(1") EPR 3014 EPR 3024

Top and Bottom22(3/4") EPR 3015 EPR 3025

11.228(1") EPR 3016 EPR 3026

460 22(3/4"),28(1")Top, Bottom, or Top and Bottom - EPR 3027 11.2

These are the combination of 30 amperes rating flameproof plugs and switched receptacles which contain a circuit breaker. The 3-pin(2 Pole + Earth)units are used for single phase load, and 4-pin(3 Pole + Earth)units for three phase load. For 400 volts circuits, 4-pin plugs and receptacles carrying "460V" marking are also available, whose arrangement of pins is different from the standard units.

Features

The main enclosure of the switched receptacle has a socket outlet on the front cover and a operating handle on the side of the body. The terminal box is fitted to the top or bottom, or the both sides of the main body.The interlocking device is of handle operation type. The builtin circuit breaker is operated by the handle, and the plug can only be inserted or with drawn when the circuit breaker is in the open position.The plug is designed for heavy duty and incorporation a flameproof packing type cable gland.A screw-on blanking cap is provided for protecting the receptacle outlet.

Page 186: Nb cat

Plug & Receptacle

Copyright by NAMBUK Electric Co., LTD. 2004

Plugs And Receptacles

EPR 30AWet Locations

Type of Explosion-proof

Flameproof-Increase Safety (Ex de IIB T6)

Specification

General Circuits Motor Protection

Rated Voltage 120, 240 or 460V AC 240 or 460V AC

Rated Current, or

Max. Motor output30A

2.5kW at 220V 11kW

at 440V

Number of Pins3 (2-Pole+Earth), or

4 (3-Pole+Earth)4 (3-Pole+Earth)

Operating time(max.) 100mS 100mS

Rated Interruptiong

Capacity2.5KA at 415V AC 2.5KA at 415V AC

< EPR 30A (31 Type) >

Dimension Standard MaterialsSwitched Receptacle Housing : Cast aluminium alloy

Terminal Box : Cast aluminium alloy

Plug Casing : Cast aluminium alloy

Standard FinishMUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

Selection Table of Rubber Packings for Cable Entries

Packing

No.

Nominal Diameter

of Cable

Suitable Chloroprene Sheathed

Portable Power Cable, Class 3

28-18 16 to 18mm 3 core 2.0mm222

28-20 18 to 20mm 3 core 3.5mm2 2 2 4 core 2.0mm222

28-21 20 to 21mm 3 core 5.5mm2 2 2 4 core 3.5mm222

28-22 21 to 22mm 3 core 8 mm2 2 2 4 core 5.5mm222

Flameproof EPR Plugs and Receptacles with Circuit Breaker 30 Amps

Rated Voltage(V)

General Circuits 4-Pin Motor Protection 4-PinWeight(Kg)Rated

CurrentCatalog No.

Max. Motor Output (kW)

Catalog No.

120 30 EPR 3111 - -

10.5240 30 EPR 3112 5.5 EPR 3115

460 30 EPR 3113 11 EPR 3116

Conduit entry-28(1") max. at top and/or bottom. Specify the position and size when ordering.+ Form 'Motor Protection' unit, specify motor output as well.Note-receptacles of different voltage rating cannot be used in common. The applicable voltage ranges of these receptacles are 80-120V for 120V rating, 160-240V rating and 20-460V for rating.

These are the combination of 30 amperes rating flameproof plugs and switched receptacles which contain a circuit breaker. The 3-pin(2 Pole + Earth)units are used for single phase load, and 4-pin(3 Pole + Earth)units for three phase load. For 400 volts circuits, 4-pin plugs and receptacles carrying "460V" marking are also available, whose arrangement of pins is different from the standard units.

Page 187: Nb cat

Plugs & Receptacle

Copyright by NAMBUK Electric Co., LTD. 2004

Plugs And Receptacles

EPR 100AWet Locations

Type of Explosion-proof

< EPR 100A >

Flameproof-Increase Safety (Ex de IIB T6)

Dimension

Flameproof EPR Plugs and Receptacles with Circuit Breaker 100 Amps

Standard MaterialsRated

Voltage

(V)

Rated

Current

(A)

Entry Position Catalog No. Weight(Kg) Switched Receptacle Housing :

cast aluminium ally

Terminal Box : cast aluminium ally

Plug Casing : cast aluminium ally

460AC

250DC

60

Top EPR 601154

Bottom EPR 6012

Top and Bottom EPR 6013 62Specification

75

Top EPR 750154

Rated Voltage 460V AC.250V DC

Rated Current 60, 75 or 100A

Number of Pins 5 (3Pole+E+N)

Rate interrupting 20KA A at 220V AC

Capacity 15KA A at 460V AC

10KA A at 250V DC

Bottom EPR 7502

Top and Bottom EPR 750362

100

Top EPR 10051

Bottom EPR 10052 54

Top and Bottom EPR 10053 62

Standard FinishMUNSELL No. 7.5BG 6/1.5

If you want another color, contact us

please.

Selection Table of Rubber Packings for Cable Enteries

Packing No.Nominal Diameter

of CableSuitable Chlorprene Sheathed Portable

power Cable, Class 3

54-37 33 to 37mm 4 core 22 mm222

54-41 37 to 41mm

54-44 41 to 44mm 4 core 38 mm222

* Unless otherwise stated plugs are supplied with No. 54-44 packing.

These are the combinations of 100amperes rating flameproof plugs and switched receptacles. Which contain a

circuit breaker, and used for movable large motors and welding units.

The construction and operation of these plugs and receptacles are mostly same as 30 amperes rating EPR Plugs

and Receptacle listed on page 79 except that the contacting part has more electrical capacity and different

mechanism.

Page 188: Nb cat

Plug & Receptacle

Copyright by NAMBUK Electric Co., LTD. 2004

Plugs And Receptacles

EPRH 20A Wet Locations

Type of Explosion-proof DimensionFlameproof-Increase Safety

(Ex de IIC T6 IP55)

EPRH-P

EPRH-R

< EPRH 20A >

Conduit Size h

16(1/2") 17

22(3/4") 20

28(1") 23

Flameproof EPR Plugs and Receptacles Standard Materials

Conduit Entry Catalog No. Weight(Kg) Switch Receptacle

Housing : Die casting aluminium

Terminal Box : Die casting aluminium

Plug Casing : Die casting aluminium

Position Size

Terminal16(1/2") EPRH 1011

4

22(3/4") EPRH 101228(1") EPRH 1013

Through-way16(1/2") EPRH 1014

Specification22(3/4") EPRH 101528(1") EPRH 1016

Rated Voltage 250V AC

Rated Current 15-20A

Number of Pins 3 (2Pole+Earth)

Selection Table of Rubber Packings for Cable EnteriesStandard Finish

Packing No.Nominal Diameter

of Cable

Suitable Chloroprene Sheathed

Portable power Cable, Class 3 MUNSELL No. 7.5BG 6/1.5

If you want another color, contact

us please.15S 13 to 15mm

16S 15 to 16mm 3 core 0.75 mm222

17S 16.5 to 17mm 3 core 2.0 mm222

*3 core 0.75mm222 Chloroprene Sheathed Potable Power Cable can be

supplied in cut lengths to suit customers' requirement

These are the combinations of 15,

20Amperes rating flameproof plugs

and switched receptacles. Which

contain a toggle type switch. These

plugs and receptacles are designed

mainly for connecting handlamps

and other portable small appliances

to stationary supply-points.

The connector has three pins, but

one pin is for earthing, and these

units are used only for single

phase load.

Features

The flameproof enclosures of the switched receptacle are composed

of the main body, barrier and terminal box, putting one on another

with spigot joints.

The interlocking device is of plug operation type. the built_in switch

can only be operated by the plug in fully engaged position, and the

plug cannot be withdrawn unless the switch is in open position.

The plug is compact and complete flameproof, and incorporates a

flameproof packing type cable gland.

The blanking cap is of spring-operated type and covers the

receptacle outlet automatically when the plug is withdrawn.

Page 189: Nb cat

Plugs & Receptacle

Copyright by NAMBUK Electric Co., LTD. 2004

Plugs And Receptacles

EPRH 100AWet Locations

Type of Explosion-proof Flameproof-Increase Safety

(Ex de IIC T6)

< EPRH 100A >

Dimension

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

Flameproof EPR Plugs and Receptacles with Circuit Breaker 100 Amps

Standard MaterialsRated

Voltage

(V)

Rated

Current

(A)

Entry Position Catalog No. Weight(Kg) Switched Receptacle Housing :

cast aluminium ally

Terminal Box : cast aluminium ally

Plug Casing : cast aluminium ally

460AC

250DC

60

Top EPRH 601154

Bottom EPRH 6012

Top and Bottom EPRH 6013 62Specification

75

Top EPRH 750154

Rated Voltage 460V AC.250V DC

Rated Current 60, 75 or 100A

Number of Pins 4 (3-Pole+Earth)

Rate interrupting 20KA A at 220V AC

Capacity 15KA A at 460V AC

10KA A at 250V DC

Bottom EPRH 7502

Top and Bottom EPRH 7503 62

100

Top EPRH 1005154

Bottom EPRH 10052

Top and Bottom EPRH 10053 62

Selection Table of Rubber Packings for Cable Enteries

Packing No.Nominal Diameter

of CableSuitable Chloroprene Sheathed Portable

power Cable, Class 3

54-37 33 to 37mm 4 core 22 mm222

54-41 37 to 41mm

54-44 41 to 44mm 4 core 38 mm222

* Unless otherwise stated plugs are supplied with No. 54-44 packing.

These are the combinations of 100amperes rating flameproof plugs and switched receptacles. Which contain a

circuit breaker, and used for movable large motors and welding units.

The construction and operation of these plugs and receptacles are mostly same as 30 amperes rating EPR Plugs

and Receptacle listed on page 79 except that the contacting part has more electrical capacity and different

mechanism.

Page 190: Nb cat

SECTION - 2P

Engineering Plastic

Plug & Receptacle

Page 191: Nb cat

SECTION 2P

Engineering Plastic Plug & Receptacle INDEXModel Product Description

Certification for

Explosion-proofpage

EFPR 16A-NBEngineering Plastic Plug & Receptacle 16A

(NAMBUK Style)Ex de C T6 IP66Ⅱ 2P - 2

EFPR 16A Engineering Plastic Plug & Receptacle 16A Ex de C T6 IP66Ⅱ 2P - 3

EFPR 32A Engineering Plastic Plug & Receptacle 32A Ex de C T6 IP66Ⅱ 2P - 4

EFPR 63A Engineering Plastic Plug & Receptacle 63A Ex de C T6 IP66Ⅱ 2P - 5

EFPR 125A Engineering Plastic Plug & Receptacle 125A Ex de C T6 IP66Ⅱ 2P - 6

Page 192: Nb cat

Plug & Receptacle

Copyright by NAMBUK Electric Co., LTD. 2004

Engineering Plastic Plugs & Receptacles

EFPR Series

Type of Explosion-proof Ex de IIC T6 IP66

Application Features

EFPR Series Plug & Receptacles are used in ;

heavy process industries having environments where

flammable or explosive vapors or gases, or where

combustible dusts are present.

petroleum refineries, chemical, petrochemical and

other heavy process industry facilities.

where ignitable concentrations of flammable gases,

vapors or liquids can exist some of the time under

normal operation conditions.

where ignitable concentrations of flammable gases,

vapors or liquids are not likely to exist under normal

operation conditions.

Enclosure in glass fiber reinforced polyester resin,

provide excellent resistant to corrosion so have a

long life.

Enclosure contain ultraviolet interception ingredient to

resist transformation.

Switches with large handles can be locked in 0 and

1 position.

Fully color-coded plug enclosure in color for voltage

and frequency.

Standard Materials

Housing : Glass fiber reinforced polyester resin

Gasket : Silicone rubber

External Hardware : Stainless steel, BrassStandard Finish

Natural

If you want another color, contact us please.

Swiching Capacity

Voltage

Cat. No. 220V- 230V- 240V- 380V- 400V- 415V- 500V- 660V- 690V-

EFPR 16A-NB 4KW - - -

EFPR 16A 4KW 7.5KW 11KW

EFPR 32A 7.5KW 15KW 18.5KW 30KW

EFPR 63A 18.5KW 30KW 37KW 55KW

If you need more information, contact us please. ⇨

Page 193: Nb cat

Plug & Receptacle

Copyright by NAMBUK Electric Co., LTD. 2004

16A-NB Receptacle (NAMBUK Style)

Number of pins Voltage Color h Catalog No. Weight Certification

220 blue 6 EFPR 16A-NBR 1.3Kg

Ex de IIC

T6 IP66

16A-NB Plug (NAMBUK Style)

Number of pins Voltage Color h Catalog No. Weight Certification

220 blue 6 EFPR 16A-NBP 0.2Kg

Ex de IIC

T6 IP66

Dimension

EFPR 16A-NBR

EFPR 16A-NBR

EFPR 16A-NBP

Page 194: Nb cat

Plug & Receptacle

Copyright by NAMBUK Electric Co., LTD. 2004

16A Receptacle

Number of pins Voltage Color h Catalog No. Weight Certification

110-130 yellow 4 EFPR 16A41R

3.7KgEx de IIC

T6 IP66

220-240 blue 9 EFPR 16A42R

380-400 red 6 EFPR 16A44R

500 black 7 EFPR 16A45R

660-690 black 5 EFPR 16A46R

110-130 yellow 4 EFPR 16A51R

220-240 blue 9 EFPR 16A52R

380-400 red 6 EFPR 16A54R

500 black 7 EFPR 16A55R

660-690 black 5 EFPR 16A56R

16A Plug

Number of pins Voltage Color h Catalog No. Weight Certification

110-130 yellow 4 EFPR 16A41P

0.29KgEx de IIC

T6 IP66

220-240 blue 9 EFPR 16A42P

380-400 red 6 EFPR 16A44P

500 black 7 EFPR 16A45P

660-690 black 5 EFPR 16A46P

110-130 yellow 4 EFPR 16A51P

220-240 blue 9 EFPR 16A52P

380-400 red 6 EFPR 16A54P

500 black 7 EFPR 16A55P

660-690 black 5 EFPR 16A56P

Dimension

EFPR 16A_R

EFPR 16A_R

EFPR 16A_P

Page 195: Nb cat

Plug & Receptacle

Copyright by NAMBUK Electric Co., LTD. 2004

32A Receptacle

Number of pins Voltage Color h Catalog No. Weight Certification

110-130 yellow 4 EFPR 32A41R

Ex de IIC

T6 IP66

220-240 blue 9 EFPR 32A42R

380-400 red 6 EFPR 32A44R

500 black 7 EFPR 32A45R

660-690 black 5 EFPR 32A46R

110-130 yellow 4 EFPR 32A51R

220-240 blue 9 EFPR 32A52R

380-400 red 6 EFPR 32A54R

500 black 7 EFPR 32A55R

32A Plug

Number of pins Voltage Color h Catalog No. Weight Certification

110-130 yellow 4 EFPR 32A41P

Ex de IIC

T6 IP66

220-240 blue 9 EFPR 32A42P

380-400 red 6 EFPR 32A44P

500 black 7 EFPR 32A45P

660-690 black 5 EFPR 32A46P

110-130 yellow 4 EFPR 32A51P

220-240 blue 9 EFPR 32A52P

380-400 red 6 EFPR 32A54P

500 black 7 EFPR 32A55P

Dimension

EFPR 32A_R EFPR 32A_R

EFPR 32A_P

Page 196: Nb cat

Plug & Receptacle

Copyright by NAMBUK Electric Co., LTD. 2004

63A Receptacle

Number of pins Voltage Color h Catalog No. Weight Certification

220-240 blue 9 EFPR 63A42R

Ex de IIC

T6 IP66

380-400 red 6 EFPR 63A44R

500 black 7 EFPR 63A45R

660-690 black 5 EFPR 63A46R

220-240 blue 9 EFPR 63A52R

380-400 red 6 EFPR 63A54R

500 black 7 EFPR 63A55R

63A Plug

Number of pins Voltage Color h Catalog No. Weight Certification

220-240 blue 9 EFPR 63A42P

Ex de IIC

T6 IP66

380-400 red 6 EFPR 63A44P

500 black 7 EFPR 63A45P

660-690 black 5 EFPR 63A46P

220-240 blue 9 EFPR 63A52P

380-400 red 6 EFPR 63A54P

500 black 7 EFPR 63A55P

Dimension

EFPR 63A_R EFPR 63A_R

EFPR 63A_P

Page 197: Nb cat

Plug & Receptacle

Copyright by NAMBUK Electric Co., LTD. 2004

125A Receptacle

Number of pins Voltage Color h Catalog No. Weight Certification

220-240 blue 9 EFPR 125A42R

Ex de IIC

T6 IP66

380-400 red 6 EFPR 125A44R

500 black 7 EFPR 125A45R

220-240 blue 9 EFPR 125A52R

380-400 red 6 EFPR 125A54R

500 black 7 EFPR 125A55R

125A Plug

Number of pins Voltage Color h Catalog No. Weight Certification

220-240 blue 9 EFPR 125A42P

Ex de IIC

T6 IP66

380-400 red 6 EFPR 125A44P

500 black 7 EFPR 125A45P

220-240 blue 9 EFPR 125A52P

380-400 red 6 EFPR 125A54P

500 black 7 EFPR 125A55P

Dimension

Page 198: Nb cat

Plug & Receptacle

Copyright by NAMBUK Electric Co., LTD. 2004

Technical Data

⁍ Receptacle

EFPR 16A-NB EFPR 16A EFPR 32A EFPR 63A EFPR 125A

Rated Voltage 220V + 5% ...690V + 5% ...690V + 5% ...690V + 5% ...690V + 5%

Rated Current 16A 16A 32A 63A 125A

Interlock Switch3 pole switch with isolating characteristics 1 auxiliary contact

(ON-delayed, OFF-advanced)

Terminal 4 X 2㎟ 4 X 2㎟ 10 X 2㎟ 35 X 1㎟ 120 X 1㎟

Ambient Temperature -20 ...+40℃ ℃ -20 ...+40℃ ℃ -20 ...+40℃ ℃ -20 ...+40℃ ℃ -20 ...+40℃ ℃

Hub bottom 1 X M25 bottom 1 X M25 bottom 1 X M32 bottom 1 X M50 bottom 1 X M63

Stopping Plug bottom 1 X M25 bottom 1 X M25 bottom 1 X M32 bottom 1 X M25 bottom 1 X M63

⁍ Plug

Terminal 4 ㎟ 4 ㎟ 10 ㎟ 16 ㎟ 35 ㎟

Cable Entry Max. Ø21㎜ Max. Ø21㎜ Max. Ø28㎜ Max. Ø36㎜ Max. Ø50㎜

⁍ Color and Arrangement

Operating Voltage

(V)

Frequency

(Hz)Color

h-position

3P 4P 5P

110-130 50/60 Yellow 4 4 4

220-240 50/60 Blue 6 9 9

380-400 50/60 Red 9 6 6

500 50/60 Black 7 7 7

660-690 50/60 Black - 5 5

Position Clockwise Front view of Plug

⁍ Accessories and Spare parts

Designation Description Catalog No.

Switch for Receptacle EFPR 16A-NB EFSS 16-NB

EFPR 16A EFSS 16

EFPR 32A EFSS 32

EFPR 63A EFSS 63

Protection cap for Plug EFPR 16A-NB 3P EFPC 163

EFPR 16A 4P EFPC 164

EFPR 16A 5P EFPC 165

EFPR 32A 4P EFPC 324

EFPR 32A 5P EFPC 325

EFPR 63A 4/5P EFPC 634

Page 199: Nb cat

SECTION - 1F

Junction Box

Page 200: Nb cat

SECTION 1F

Junction Boxes INDEX

Model Product DescriptionCertification for Explosion-proof

Page

IEC UL

SBD Increase Safety Junction Boxes Ex e Ⅱ 1F - 1

EOB Flameproof Junction Boxes Ex d II C

Class I

Group C,D

Class II

Group E,F,G

1F - 2

EOS Junction Boxes with Union Hubs Ex d CⅡ 1F - 3

WAB Increase Safety Junction BoxesEx e II T6

Ex DP II 131F - 4

SWAB Increase Safety Junction Boxes Ex e II T6 1F - 5

EFCS-T Engineering Plastic Terminal Box Ex e II T6 IP66 1F - 6

EJG Flameproof Junction Boxes Ex d IIC T6 Ex d IIC T6 1F - 8

EBGC Flameproof Junction Boxes Ex d IIB T6 1F - 10

Page 201: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

Conduit SizeDimension

A B C D16 ½" 127 89 62 115

22 ¾" 127 89 62 115

28 1" 141 89 66 122

36 1¼" 170 106 90 148

42 1½" 170 106 90 148

54 2" 204 124 120 182

Application

SBD junction boxes are used ;

in originally designed for humid or dusty locations.

together with the SD Elbows shown on page

because of their higher quality on strength, dustproof

and weatherproof.

they are used securely for conduit wiring in Division

2 hazardous areas.

in select the proper entry position and size of box in

accordance with the location and the use.

Features

These boxes of conduit sized 16(1/2"), 22(3/4"), and

28(1") can be used for the mounting box of

increased safety SYL Incandescent and SYFL

Fluorescent Lighting Fittings, and vapour-tight VDY

Incandescent Lighting Fittings.

Standard Materials

Cast Iron

Cast Aluminium

Standard Finish

Hot Dip Galvanized with stove enamelled

Cast Al : MUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

If you need more information, contact us please.⇨

Ordering Number

<Dimension> EntriesConduit

Size

Catalog

NumberWeight

( )㎏Flat Cover

Terminal

16 1/2" SBD1016 1.8

22 3/4" SBD1022 1.8

28 1" SBD1028 2.0

36 1-1/4" SBD1036 3.5

42 1-1/2" SBD1042 3.9

54 2" SBD1054 5.5

Through

-Way

16 1/2" SBD2116 1.8

22 3/4" SBD2122 1.8

28 1" SBD2128 2.0

36 1-1/4" SBD2136 3.4

42 1-1/2" SBD2142 3.8

54 2" SBD2154 5.4

Angle

16 1/2" SBD2216 1.7

22 3/4" SBD2222 1.7

28 1" SBD2228 1.9

36 1-1/4" SBD2236 3.3

42 1-1/2" SBD2242 3.6

54 2" SBD2254 5.2

Three

-Way

16 1/2" SBD3016 1.8

22 3/4" SBD3022 1.8

28 1" SBD3028 2.0

36 1-1/4" SBD3036 3.5

42 1-1/2" SBD3042 3.9

54 2" SBD3054 5.5

Four

-Way

16 1/2" SBD4022 1.7

22 3/4" SBD4028 1.7

28 1" SBD4036 1.9

36 1-1/4" SBD4042 3.4

42 1-1/2" SBD4054 3.7

54 2" SBD4054 5.3

Compliance

IEC 60079-0, 7

Certification

Certified by KOSHA (Korea Occupational Safety &Health Agency), KGS (Korea Gas SafetyCorporation), and the others.

Increase Safety Junction Boxes

SBD Series

Type of Explosion-proof

Increase Safety ( Ex e II )

< SBD >

Page 202: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

Flameproof Junction Boxes

EOB Series

Type of Explosion-proof Ordering Number

<Dimension> EntryConduit

Size

Catalog NumberWeight

( )㎏

Flameproof ( Ex d IIC )

Class I Group C,D Class II Group E,F,GFlat

Cover

Dome

Cover

Terminal

16 1/2" EOB1016 EOBD1016 1.8

22 3/4" EOB1022 EOBD1022 1.8

< EOB >

28 1" EOB1028 EOBD1028 2.0

36 1-1/4" EOB1036 EOBD1036 3.5

42 1-1/2" EOB1042 EOBD1042 3.9

54 2" EOB1054 EOBD1054 5.5

Through-Way

16 1/2" EOB2116 EOBD2116 1.8

22 3/4" EOB2122 EOBD2122 1.8

28 1" EOB2128 EOBD2128 2.0

36 1-1/4" EOB2136 EOBD2136 3.4

42 1-1/2" EOB2142 EOBD2142 3.8

54 2" EOB2154 EOBD2154 5.4

Angle

16 1/2" EOB2216 EOBD2216 1.7Conduit Size

Dimension

22 3/4" EOB2222 EOBD2222 1.7A B C D E F

28 1" EOB2228 EOBD2228 1.916 1/2" 85 132 79 8 116 116

36 1-1/4" EOB2236 EOBD2236 3.322 3/4" 85 132 82 8 116 116

42 1-1/2" EOB2242 EOBD2242 3.628 1" 85 142 86 8 121 121

54 2" EOB2254 EOBD2254 5.236 1-1/4" 106 170 96 10 148 148

42 1-1/2" 106 170 102 10 148 148

Three-Way

16 1/2" EOB3016 EOBD3016 1.8

54 2" 142 234 164 10 198 198 22 3/4" EOB3022 EOBD3022 1.8

28 1" EOB3028 EOBD3028 2.0

Application 36 1-1/4" EOB3036 EOBD3036 3.5

42 1-1/2" EOB3042 EOBD3042 3.9EOB junction boxes are used ;in indispensable for splicing and branching ofconductors for electrical wiring in explosive gasatmosphere.in various products in accordance with applicableconduit sizes and positions of entries are supplied asstandard.in select suitable type and dimensions according tothe location.

54 2" EOB3054 EOBD3054 5.5

Four-Way

16 1/2" EOB4022 EOBD4022 1.7

22 3/4" EOB4028 EOBD4028 1.7

28 1" EOB4036 EOBD4036 1.9

36 1-1/4" EOB4042 EOBD4042 3.4

42 1-1/2" EOB4054 EOBD4054 3.7

54 2" EOB4054 EOBD4054 5.3

Compliance CertificationFeatures

IEC 60079-0, 1

ANSI/UL 886

ANSI/UL 514A

Certified by KOSHA (KoreaOccupational Safety &Health Agency), KGS (KoreaGas Safety Corporation),and the others.

The cover is ;Thread-jointed to the bodySynthetic rubber O-ring is used outside of the joint.Assured flameproof, weatherproof and dust-tight areobtained.When the connections of conductors are bulky or thetreatment of wiring is difficult.Recommend to use the EOBD Junction Boxes withdome cover.

Dome Cover

Standard Materials

Cast Iron

If you want another color, contact us please.

The dome cover can be fitted with the splices ofconductors standing as shown in the photograph.Splicings and treatments of many conductors caneasily be done without suffering damages in theboxes.

Standard Finish

Cast Iron : Hot Dip Galvanized with stove enamelledCast Al : MUNSELL No. 7.5BG 6/1.5If you want another color, contact us please.

Page 203: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

Junction Boxes with Union Hubs

EOS Series

Type of Explosion-proof

Flameproof ( Ex d IIC )

Dimension

< EOS >

Application Features Compliance & Certification

EOS Series junction boxes with

union hubs are used ;

in Threaded rigid conduit

systems in hazardous areas

to allow easy disassembly of

conduit system

to function as junction and pull

box for multiple conductors and

conduits

in Indoors or outdoors where

space is limited, such as in

gasoline pumps

Supplied with union hubs which

makes it a compact assembly

Have a variety of hub

arrangements

Covers are threaded

Mounting straps are standard on

all boxes

IEC 60079-0, 1

Certified by KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas Safety

Corporation), and the others.

Size Range

1/2" ~ 1" Hub

Standard MaterialsStandard FinishBody : Cast Iron

Cover : Cast Aluminium Alloy Cast Iron : Hot Dip Galvanized

with stove enamelled

Cast Al : MUNSELL NO.7.5BG

6/1.5

Ordering Number Ordering InformationHub Size Ordering Number

A B C D E with Nuts and Sleeves

1/2" 1/2" 1/2" EOS 3000

3/4" 3/4" 3/4" EOS 3111

1/2" 3/4" 3/4" EOS 3011

3/4" 1/2" 1/2" EOS 3100

3/4" 1" 1" EOS 3122

3/4" 1" 3/4" EOS 3121

1"3/4" 3/4" EOS 3211

1"3/4" 1" EOS 3212

1"1" 1" EOS 3222

3/4" 3/4" 3/4" 3/4" EOS 41111

3/4" 3/4" 3/4" 3/4" 3/4"EOS 511111

EOS 5 11111

EO S 4 11 11① ② ③

: EOS Junction Box①

: Nos. of Hub②

: Hub Size③

0 : 1/2"

1 : 3/4"

2 : 1"

(Marking In order of top left to top right, bottom

left to bottom right)

If you need more information, contact us please.⇨

Page 204: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

Increase Safety Junction Boxes

WAB Series

Type of Explosion-proof

Increase Safety ( Ex e II T6)

Dust Ignition-proof (Ex DP II 13)

Application Features

Flat neoprene gasket cemented to cover.Wide range of drilled and tapped and slip holeconduit entrance sizes and locations permitsmaximum flexibility of use in conduit system.Choice of locations for holes blind tapped intointernal mounting pads.

Where a heavy duty dust-tight or Weatherproof enclosureis desired, WAB boxes are installed in conduit systems to ;act as pull box for conductors.provide Openings and space for making splices andtaps in conductors.provide access to conductors for maintenance andfuture system changes.

Compliance& CertificationStandard Materials IEC 60079-0, 7

Certified by KOSHA (Korea Occupational Safety &Health Agency), KGS (Korea Gas SafetyCorporation), and the others.

Cover and Body : Cast aluminium alloyNeoprene gasketsStainless steel cover screws

Standard FinishOptions

Drain plug & Breather MUNSELL No. 7.5BG 6/1.5if you want another color, contact us please.

< WAB >

CatalogNumber

Max. conduitsize

Max. No ofTerminals

A B C D E F∅WAB040403 28 1" Max. 2.5mm2 × 8P 120 120 145 70 80 2- 8∅WAB060604 28 1" Max. 2.5mm2 × 10P 180 180 200 100 120 2- 10∅WAB080804 28 1" Max. 2.5mm2 × 20P 230 230 260 140 120 4- 10∅WAB080808 42 1-1/2" Max. 2.5mm2 × 20P 230 230 260 140 225 4- 10∅WAB100808 42 1-1/2" Max. 2.5mm2 × 40P 230 280 260 200 225 4- 10∅WAB121008 42 1-1/2" Max. 2.5mm2 × 60P 285 340 320 210 230 4- 12∅WAB121010 42 1-1/2" Max. 2.5mm2 × 60P 285 340 320 210 280 4- 12∅WAB121208 54 2" Max. 2.5mm2 × 60P 335 335 370 210 240 4- 12∅WAB121210 54 2" Max. 2.5mm2 × 60P 335 335 370 210 280 4- 12∅WAB141408 70 2-1/2" Max. 2.5mm2 × 60P 385 385 420 260 230 4- 12∅WAB141410 70 2-1/2" Max. 2.5mm2 × 60P 385 385 420 260 280 4- 12∅WAB161008 70 2-1/2" Max. 2.5mm2 × 60P 270 425 300 360 245 4- 12∅WAB161010 70 2-1/2" Max. 2.5mm2 × 60P 270 425 300 360 285 4- 12∅WAB241408 82 3" Max. 2.5mm2 × 100P 325 630 350 570 250 4- 12∅WAB241410 82 3" Max. 2.5mm2 × 100P 325 630 350 570 285 4- 12∅WAB242008 82 3" Max. 2.5mm2 × 250P 630 540 665 480 240 4- 12∅WAB281408 104 4" Max. 2.5mm2 × 120P 385 740 415 680 285 4- 15∅WAB351408 104 4" Max. 2.5mm2 × 120P 385 920 415 680 230 4- 18∅WAB353311 104 4" Max. 1000A 900 850 950 800 325 4- 18∅

Page 205: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

Increase Safety Junction Boxes

SWAB Series

Type of Explosion-proofRating Max. 600V◎

IP Rating : IP65◎Increase Safety (Ex e II T6)

Application Features

Flat neoprene gasket cemented to cover.

Wide range of drilled and tapped and slip hole

conduit entrance sizes and locations permits

maximum flexibility of use in conduit system.

Choice of locations for holes blind tapped into

internal mounting pads.

Where a heavy duty dust-tight or weatherproof enclosure

is desired, SWAB boxes are installed in conduit systems

to ;

act as pull box for conductors.

provide Openings and space for making splices and

taps in conductors.

provide access to conductors for maintenance and

future system changes.

enclose and protect electrical device.

Compliance& CertificationStandard Materials IEC 60079-0, 7

Certified by KOSHA (Korea Occupational Safety &

Health Agency), KGS (Korea Gas Safety

Corporation), and the others.

Cover and Body : Stainless steel

Neoprene gaskets

Cover bolts, door handle : Stainless steelOptions

Terminals can fitted to order.

Cable glands can fitted to order.

Sockets can fitted to order.Standard Finish

Natural

If you want another color, contact us please. Dimension

< SWAB >

Catalog Number Nos. of TerminalDimension (mm)

DEPTHA B C D

SWAB 303020 Max. 20p 300 300 200 340

200

SWAB 353520 Max. 40p 350 350 250 390

SWAB 404020 Max. 40p 400 400 300 440

SWAB 505020 Max. 80p 500 500 400 540

SWAB 616120 Max. 160p 610 610 510 650

* Above nos. of terminal are standard. For example SWAB 353520 can install 80p of

terminal, but T glade is lower then. If you want more terminals, contact us.

Page 206: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

Engineering Plastic Terminal Box

EFCS-T Series

Type of Explosion-proofIncrease Safety (Ex e II T6 IP66)

Application Features

EFCS-T Series Terminal Boxes are used ;

in Heavy process industries having environments

where flammable or explosive vapors or gases, or

where combustible dusts are present

in Petroleum refineries, chemical, petrochemical and

other heavy process industry facilities

where ignitable concentrations of flammable gases,

vapors or liquids can exist some of the time under

normal operation conditions.

where ignitable concentrations of flammable gases,

vapors or liquids are not likely to exist under normal

operation conditions.

where combustible dust, moisture, dirt are present

and vibration, corrosion, rough usage are problems

Enclosure in glass fiber reinforced polyester resin,

provide excellent resistant to corrosion so have a

long life.

Enclosure contain ultraviolet interception ingredient to

resist transformation.

Easy installation and maintenance

Metal cable entries can be fitted. They are crewed

into brass plates and via these incorporated into the

earthing system of the enclosure.

Standard Materials

Housing, mounting modules, component pallets :

Glass fiber reinforced polyester resin

Gasket : Silicone rubber

External Hardware : Stainless steel, Brass

Terminal : increase safety type

(standard : WDU Series (Weidmuller))

Options

Terminals can fitted to order.

Cable glands can fitted to order.

Sockets can fitted to order.

( Suffix : SC )Standard Finish

Natural

If you want another color, contact us please.

If you need more information, contact us please.⇨

Page 207: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

Technical Data

Terminal Catalog No.

Type Size ( )㎟ Current(A) EFCS 1200T EFCS 2800T EFCS 5542T

Max. No. of Terminals

(P)

WDU 2.5 2 25 40 60 120

WDU 4 3.5 35 40 60 120

WDU 6 5.5 45 30 30 60

WDU 10 8 60 20 20 40

RatingMax. 550V,

40P

Max. 550V,

80P

Max. 550V,

120P

Max. No. of Cable Gland

1/2" 22Ø 6 6 18

1" 28Ø 4 4 12

1-1/2" 36Ø (3) 4 10

1-1/2" 42Ø (3) (3) 6

2“54Ø - - 6 -

2-1/2" 70Ø - - 4

3“82Ø - - 2 -

4“104Ø - - 2 -

Dimension (mm)

A 342 342 550

B 172 342 420

C 100 100 200

Certification Ex e II T6 IP66

-

Page 208: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

Flameproof Junction Boxes

EJG Series

Wet Locations

Raintight

NEMA 4,7,9

<EJG 20> <EJG 30> <Self Standing>

Type of Explosion-proofFlameproof (Ex d IIC T6)

Features Standard MaterialsApplication

Threaded construction

throughout permits use in

hazardous areas

Wide variety of conduit hub

arrangements

Hubs provide integral bushings

Covers are sealed with optional

"O"ring gasket when watertight

enclosures are required

Internal grounding lug provides

a means to ground enclosed

equipment

Body : Cast aluminium alloy

Cover : Cast aluminium alloyEJG series Junction boxes are used ;

in threaded rigid conduit system in

hazardous areas

to function as a splice box, pull

box or equipment and device

enclosure

in Indoors and outdoors

Compliance & Certification

IEC 60079-0, 1

UL Listed File No.

Certified by UL (Underwriters

Laboratories Inc.), KOSHA (Korea

Occupational Safety & Health

Agency), KGS (Korea Gas Safety

Corporation), and the others.

Standard Finish

Zinc chromated

MUNSELL No. 7.5BG 6/1.5

Threaded Covers for EJG Junction Boxes

Flat Cover

Glass Cover

Dome Covers

Application FeaturesEJG threaded covers are used ;

with EJG boxes in control

systems in hazardous areas

Indoors and outdoors

In three categories :

+Flat - for normal use :

furnished with standard EJG

boxes

+Glass window - to provide

visibility of meter indications

when used to enclose meters

+Domed - for increasing

volume of EJG to make it

easier to splice and pull large

conductors

Domed - more suitable for use

when splices of heavy

conductors are made and

enclosed, since the conductors

may be pulled in with the ends

outside the box. After the splices

are made, they do not have to

be crowded back into the box

Glass window has maximum

diameter glass to give best

visibility. In selecting, the

diameter of the meter face

should match or be slightly

smaller than window diameter

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color,

contact us please.

Standard Materials

Cast aluminium alloy

⇨ Flat cover is standard. Suffix GC for Glass Cover, and DC for Dome Cover. ex) EJG 21 DC

Page 209: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

Body Dimension

EJG 20 EJG 30 Self Standing TypeCATALOG

NO.

DIMENSIONS (mm)

A B C D E F

EJG 10

Series

EJG 11 118 118 118 - - -

EJG 12 130 130 87 - - -

EJG 13 145 145 131 113 170 10

EJG 20

Series

EJG 20 157 157 130 113 180 10

EJG 21 165 178 140 146 190 10

EJG 22 203 254 150 222 228 10

EJG 23 216 254 180 222 240 10

* EJG 23S 216 254 180 63 245 10

EJG 30

Series

EJG 31 280 305 240 260 308 12

* EJG 31S 280 305 240 89 308 12

EJG 32 357 459 343 407 386 12

EJG 33 480 530 430 457 534 13

EJG 23S, 31S are Self Standing Type.※

Cover DimensionCover

For Body

EJG DC Dim.(mm) EJG GC Dim.(mm)

EJG GC(Glass Cover)

A B C A B C

EJG 21 120 70 102159 50 90

EJG 21* 120 232 264

EJG 22 166 130 172 209 55 120

EJG 23 / 23S 166 130 172 209 55 120

EJG 31 228 203 266280 50 172

EJG 31S 228 388 442

EJG 32 300 90 166 - - -

EJG 33 300 370 446 - - -

* Suffix DCL when order large size dome cover in EJG 21 body.

EJG DC(Dome Cover)

Page 210: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

Flameproof Junction Boxes

EBGC Series

Type of Explosion-proofFlameproof (Ex d IIB T6) Dimension

< EBGC >

Application Features

EBGC junction boxes are used ;

in threaded rigid conduit systems in hazardous areas;

as a junction or pull box

to provide enclosures for splices and branch circuit taps

for housing terminal blocks, relays and other electrical

devices

in Indoor or outdoor in damp, wet, dusty, corrosive,

hazardous locations

where exposure to frequent or heavy rain, water, spray,

moisture, and humidity is common; such as : offshore

drilling facilities, cooling towers, coal preparation and

handling facilities and sewage and waste water treatment

plant

in areas which are hazardous due to the presence of

gases and vapors of equivalent hazard such as found in

process industries and gas manufacturing plants

Ground joint cover opening provides maximum

opening for pulling wires or mounting equipment.

Walls of selected bodies may be drilled and tapped

for conduit entries

Flat cover provides additional space for mounting a

greater number of control devices.

Standard Finish

MUNSELL No. 7.5BG 6/1.5

If you want another color, contact us please.

Standard Materials

Body & Cover : Cast aluminium alloy

CertificationCompliance

Certified by KOSHA (Korea Occupational Safety &

Health Agency), KGS (Korea Gas Safety

Corporation), and the others.

IEC 60079-0, 1

IP 55

IP 65 (Order made)

Explosion Proof EBGC Junction Boxes

Catalog No.Max. Conduit

Size

Max. No. of

TerminalsA B C D E F G

EBGC 91 42 1-1/2" 20P 290 170 260 200 145 155 11

EBGC 92 42 1-1/2" 30P 300 260 270 300 145 155 11

EBGC 93 42 1-1/2" 30P 320 300 280 340 145 155 11

EBGC 94 54 2" 60P 380 260 340 300 175 190 11

EBGC 95 54 2" 80P 460 330 420 360 175 190 11

EBGC 96 70 2-1/2" 80P 560 350 500 400 205 220 17

EBGC 97 70 2-1/2" 80P 500 500 460 550 205 220 17

EBGC 98 82 3" 120P 750 500 690 550 250 270 17

EBGC 100 104 4" 3P (500A) 1000 600 600 680 500 500 25

If you need more information, contact us please.⇨

Page 211: Nb cat

SECTION - 2F

Elbow & Union

Page 212: Nb cat

SECTION 2F

Elbows & Union INDEX

Model Product DescriptionCertification for Explosion-proof

Page

IEC UL

EXY Elbow Ex d CⅡClass Group C,D Ⅰ

Class Group E,F,GⅡ2F - 1

EXA Elbow Ex d CⅡ 2F - 2

EXT Elbow Ex d CⅡ 2F - 2

EFA Elbow Ex d BⅡ 2F - 2

ELZ Elbow Ex d CⅡ 2F - 3

SDC Conduit Body Ex e II 2F - 5

SDLB Conduit Body Ex e II 2F - 5

SDLL Conduit Body Ex e II 2F - 5

SDLR Conduit Body Ex e II 2F - 6

SDT Conduit Body Ex e II 2F - 6

SDTB Conduit Body Ex e II 2F - 6

SDX Conduit Body Ex e II 2F - 7

EUX Union Ex d IIC

Class I Group C,D

Class II Group

E,F,G

2F - 8

Page 213: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

Elbow & Union

Elbow Series

Application

These Elbows are used in ;

act as pull outlet.

provide access to conductors for maintenance and

future system changes.

make 90° bends in conduits system where space is

limited.

provide access to wiring for maintenance and future

system changes.

allow single conduit stub up to outlet and device

boxes located above or below min conduit runs.

where ignitable concentrations of flammable gases,

vapors or liquids can exist some of the time under

normal operation conditions.

Compliance& Certification

IEC 60079-0, IEC 60079-1

ANSI/UL 886

Certified by UL (Underwriters Laboratories Inc.),

KOSHA (Korea Occupational Safety & Health Agency),

KGS (Korea Gas Safety Corporation), and the others. Features

Cover openings on an angle, permitting conductors

to be pulled straight through either hub.

Taper tapped hubs and integral bushing for rigid

threaded conduit.

Maximum volume for bends within a compact

overall size.

Domed covers to permit easy conductor bends.

Screw on cover for ease of installation and removal

UL Listed File No. E143517 (EXY series).

Standard Materials

Body : Cast Iron

Cover : Cast Iron

Standard Finish

Hot Dip. Galvanized with stove enamelled

If you want another color, contact us please.

Options

NPT Thread : suffix. NPT

Type of Explosion-proof

◎ EXYFlameproof ( Ex d IIC)

Class I Group C,D Class II Group E,F,G

Hub Size1/2"

16C

3/4"

22C

1"

28C

1-1/4"

36C

1-1/2"

42C

2"

54C

2-1/2"

70C

3"

82C

Cat. No. EXY1100 EXY1111 EXY1122 EXY1133 EXY1144 EXY1155 EXY1166 EXY1177

Dimension

a 64 57 64 83 85 102 138 138

b 71 75 93 104 114 132 138 138

c 90 88 115 136 148 167 218 237

d 84 90 102 115 126 144 187 200

If you need more information, contact us please. ⇨

Page 214: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

◎ EXA Type of Explosion-proof

Flameproof ( Ex d IIC)

Hub Size1/2"

16C

3/4"

22C

1"

28C

1-1/4"

36C

1-1/2"

42C

2"

54C

2-1/2"

70C

3"

82C

Cat. No. EXA1200 EXA1211 EXA1222 EXA1233 EXA1244 EXA1255 EXA1266 EXA1277

Dimension

a 65 65 65 85 85 102 138 138

b 60 70 74 96 105 114 134 147

c 80 83 84 105 113 130 166 180

◎ EXT Type of Explosion-proof

Flameproof ( Ex d IIC)

Hub Size1/2"

16C

3/4"

22C

1"

28C

1-1/4"

36C

1-1/2"

42C

2"

54C

2-1/2"

70C

3"

82C

Cat. No. EXT1300 EXT1311 EXT1322 EXT1333 EXT1344 EXT1355 EXT1366 EXT1377

Dimension

a 65 65 65 85 85 102 138 138

b 60 70 74 100 105 114 134 147

c 95 101 103 125 142 158 216 240

d 80 83 84 105 113 130 166 180

◎ EFA Type of Explosion-proof Flameproof ( Ex d IIB)

Hub Size1/2"

16C

3/4"

22C

1"

28C

1-1/4"

36C

1-1/2"

42C

2"

54C

2-1/2"

70C

3"

82C

Cat. No. EFA 140 EFA 141 EFA 142 EFA 143 EFA 144 EFA 145 EFA 146 EFA 147

Dimension

a 128 128 200 200 270 270 400 400

b 66 66 86 86 114 114 140 140

c 101 101 130 130 175 175 240 240

d 78 78 98 98 124 124 144 144

Page 215: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

◎ ELZ Type of Explosion-proof

Flameproof ( Ex d IIC)

TypeHub

SizeCat. No.

Dimen.

A B

90°

Male

1/2" 16C ELZ 9016 35 35

3/4" 22C ELZ 9022 42 42

1" 28C ELZ 9028 51 51

1-1/4" 36C ELZ 9036 54 54

1-1/2" 42C ELZ 9042 - -

2" 54C ELZ 9054 - -

90°

Female

1/2" 16C ELZF 9016 38 38

3/4" 22C ELZF 9022 45 45

1" 28C ELZF 9028 51 51

1-1/4" 36C ELZF 9036 57 57

1-1/2" 42C ELZF 9042 102 102

2" 54C ELZF 9054 127 127

45°

Female

1/2" 16C ELZ 4516 30 30

3/4" 22C ELZ 4522 35 35

1" 28C ELZ 4528 42 42

1-1/4" 36C ELZ 4536 45 45

1-1/2" 42C ELZ 4542 49 49

2" 54C ELZ 4554 58 58

90°

Male &

Female

1/2" 16C ELZMF 9016 35 35

3/4" 22C ELZMF 9022 45 42

1" 28C ELZMF 9028 51 51

1-1/4" 36C ELZMF 9036 57 57

1-1/2" 42C ELZMF 9042 102 98

2" 54C ELZMF 9054 127 120

Page 216: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

Elbow & Union

SD Conduit Body Series

Type of Explosion-proof

Increase Safety ( Ex e II )

Application

SD Series Conduit bodies are installed in;

act as pull outlet bodies for conductors being

installed.

provide openings for making splices and taps in

conductors.

act as mounting outlets for lighting fixtures and wiring

devices.

connect conduit sections.

provide taps for branch conduit runs.

make 90° bends in conduit runs.

provide for access to conductors for maintenance and

future system changes.

where ignitable concentrations of flammable gases,

vapors or liquids can exist some of the time under

normal operation conditions. Standard Materials

Body : Cast Iron

Cover : Cast Iron

Gasket : Neoprene

Features Standard Finish

2 product sizes (Large, Middle).

7 shapes (C, LB, LL, LR, T, TB, X).

10 conduit sizes (1/2, 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3,

3-1/2, 4").

SD-M series conduit bodies approach conduit in size

for neat, compact installations.

SD-L series conduit bodies provide more room for

heavier conductors.

SD-L series conduit bodies are standard products.

Most of SD-L series conduit bodies get UL

Certification.

Conduit hubs have tapered threads and feature

integral bushings for protection of wire insulation.

Smooth integral wire bushings protects cable form

damage when wires are pulled through opening.

Solid gaskets or Open gaskets

Hot Dip. Galvanized with stove enamelled silver

white

If you want another color, contact us please.

OptionNPT Thread : suffix. NPT

Compliance

IEC 60079-0, 7

ANSI/UL 886

UL Listed File No. E142233

Certification

Certified by UL (Underwriters Laboratories Inc.),

KOSHA (Korea Occupational Safety & Health

Agency), KGS (Korea Gas Safety Corporation), and

the others.

Page 217: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

C Type

Hub

Size

1/2"

16C

3/4"

22C

1"

28C

1-1/4"

36C

1-1/2"

42C

2"

54C

2-1/2"

70C

3"

82C

3-1/2"

92C

4"

104C

Cat. No.SDC

510M

SDC

511M

SDC

512M

SDC

513M

SDC

514M

SDC

515M

SDC

516M

SDC

517M

SDC

518M

SDC

519M

Dimen

sion

a 137 152 178 196 210 235 302 302 360 360

b 35 40 45 58 64 75 108 108 134 134

c 35 42 48 59 66 80 94 113 127 140

d 25 29 33 45 51 61 90 90 114 114

e 66 82 98 105 116 136 171 171 200 200

Cat. No.SDC

510L

SDC

511L

SDC

512L

SDC

513L

SDC

514L

SDC

515L

SDC

516L

SDC

517L- -

Dimen

sion

a 145 169 201 218 252 306 396 396 - -

b 34 45 48 58 69 95 124 124 - -

c 37 53.5 58 66 74 90 113 122 - -

d 25 32 35 44 52 76 110 110 - -

e 80 96 110 127 157 210 276 276 - -

LB Type

Hub

Size

1/2"

16C

3/4"

22C

1"

28C

1-1/4"

36C

1-1/2"

42C

2"

54C

2-1/2"

70C

3"

82C

3-1/2"

92C

4"

104C

Cat.

No.SDLB

520M

SDLB

521M

SDLB

522M

SDLB

523M

SDLB

524M

SDLB

525M

SDLB

526M

SDLB

527M

SDLB

528M

SDLB

529M

Dime

nsion

a 115.5 132 155 172 184.5 208.5 267 267 322 322

b 35 40 45 58 64 75 108 108 134 134

c 55 62 71.5 84.5 93.5 110.5 130 149 167 180

d 25 29 33 45 51 61 90 90 114 114

e 66 82 98 105 116 136 171 171 200 200

Cat. No.SDLB

520L

SDLB

521L

SDLB

522L

SDLB

523L

SDLB

524L

SDLB

525L

SDLB

526L

SDLB

527L

SDLB

528L

SDLB

529L

Dime

nsion

a 130 150 175.5 195 225 283 356 356 428 428

b 37 45 48 58 68 96 130 130 162 162

c 55 69 82 85.5 102 130 155.5 165 192 198.5

d 25 32 35 44 52 76 110 110 140 140

e 80 96 110 127 153 206 276 276 330 330

LL Type

Hub

Size

1/2"

16C

3/4"

22C

1"

28C

1-1/4"

36C

1-1/2"

42C

2"

54C

2-1/2"

70C

3"

82C

3-1/2"

92C

4"

104C

Cat. No.

SDLL 520M

SDLL 521M

SDLL 522M

SDLL 523M

SDLL 524M

SDLL 525M

SDLL 526M

SDLL 527M

SDLL 528M

SDLL 529M

Dimen

sion

a 115.5 132 155 172 184.5 208.5 267 267 322 322

b 56 61 70.5 85.5 91.5 105.5 146 146 175 175

c 35 42 48 59 66 80 94 113 127 140

d 25 29 33 45 51 61 90 90 114 114

e 66 82 98 105 116 136 171 171 200 200

Cat. No. SDLL 520L

SDLL 521L

SDLL 522L

SDLL 523L

SDLL 524L

SDLL 525L

SDLL 526L

SDLL 527L - -

Dimen

sion

a 130 150 176 194 226 281 356 356 - -

b 56 63 74 83.5 100 130 173 173 - -

c 36 51 57 60 70 90 113 122 - -

d 24 32 35 44 52 76 110 110 - -

e 80 96 110 127 157 210 276 276 - -

Page 218: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

LR Type

Hub

Size

1/2"

16C

3/4"

22C

1"

28C

1-1/4"

36C

1-1/2"

42C

2"

54C

2-1/2"

70C

3"

82C

3-1/2"

92C

4"

104C

Cat. No.SDLR

540M

SDLR

541M

SDLR

542M

SDLR

543M

SDLR

544M

SDLR

545M

SDLR

546M

SDLR

547M

SDLR

548M

SDLR

549M

Dime

nsion

a 115.5 132 155 172 184.5 208.5 267 267 322 322

b 56 61 70.5 85.5 91.5 105.5 146 146 175 175

c 35 42 48 59 66 80 94 113 127 140

d 25 29 33 45 51 61 90 90 114 114

e 66 82 98 105 116 136 171 171 200 200

Cat. No.SDLR

540L

SDLR

541L

SDLR

542L

SDLR

543L

SDLR

544L

SDLR

545L

SDLR

546L

SDLR

547L- -

Dime

nsion

a 130 150 176 194 226 281 356 356 - -

b 56 63 74 83.5 100 130 173 173 - -

c 36 51 57 60 70 90 113 122 - -

d 24 32 35 44 52 76 110 110 - -

e 80 96 110 127 157 210 276 276 - -

T Type

Hub

Size

1/2"

16C

3/4"

22C

1"

28C

1-1/4"

36C

1-1/2"

42C

2"

54C

2-1/2"

70C

3"

82C

3-1/2"

92C

4"

104C

Cat.

No.SDT

550M

SDT

551M

SDT

552M

SDT

553M

SDT

554M

SDT

555M

SDT

556M

SDT

557M

SDT

558M

SDT

559M

Dime

nsion

a 137 152 178 196 210 235 302 302 360 360

b 56 61 70.5 85.5 91.5 105.5 146 146 175 175

c 35 42 48 59 66 80 94 113 127 139.5

d 25 29 33 45 51 61 90 90 114 114

e 66 82 98 105 116 136 171 171 200 200

Cat. No.SDT

550L

SDT

551L

SDT

552L

SDT

553L

SDT

554L

SDT

555L

SDT

556L

SDT

557L- -

Dime

nsion

a 145 165 200 218 250 306 396 396 - -

b 56 65 75 83.5 100 130 170 170 - -

c 44 50 57 65 70 90 113 122 - -

d 25 32 35 44 52 76 110 110 - -

e 80 96 109 127 157 210 276 276 - -

TB Type

Hub

Size

1/2"

16C

3/4"

22C

1"

28C

1-1/4"

36C

1-1/2"

42C

2"

54C

2-1/2"

70C

3"

82C

3-1/2"

92C

4"

104C

Cat. No.

SDTB 560M

SDTB 561M

SDTB 562M

SDTB 563M

SDTB 564M

SDTB 565M

SDTB 566M

SDTB 567M

SDTB 568M

SDTB 569M

Dime

nsion

a 137 152 178 196 210 235 302 302 360 360

b 35 40 45 58 64 75 108 108 133 133

c 55 62 71.5 84.5 93.5 110.5 130 149 167 180

d 25 29 33 45 51 61 90 90 114 114

e 66 82 98 105 116 136 171 171 200 200

Cat. No. SDTB 560L

SDTB 561L

SDTB 562L

SDTB 563L

SDTB 564L

SDTB 565L

SDTB 566L

SDTB 567L

SDTB 568L

SDTB 569L

Dime

nsion

a 166 200 218 249 306 - - - -

b 45 48 58 68 95 - - - -

c 69 82 91.5 100 123 - - - -

d 32 35 44 52 76 - - - -

e 96 110 127 157 210 - - - -

Page 219: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

X Type

Hub

Size

1/2"

16C

3/4"

22C

1"

28C

1-1/4"

36C

1-1/2"

42C

2"

54C

2-1/2"

70C

3"

82C

3-1/2"

92C

4"

104C

Cat. No.

SDX 570M

SDX 571M

SDX 572M

SDX 573M

SDX 574M

SDX 575M

SDX 576M

SDX 577M

SDX 578M

SDX 579M

Dimen

sion

a 137 152 178 196 210 235 302 302 360 360

b 77 82 96 113 119 136 184 184 217 217

c 35 42 48 59 66 80 94 113 127 139.5

d 25 29 33 45 51 61 90 90 114 114

e 66 82 98 105 116 136 171 171 200 200

Cat. No. SDX 570L

SDX 571L

SDX 572L

SDX 573L

SDX 574L

SDX 575L - - - -

Dimen

sion

a 166 199 218 249 306 - - - -

b 81 98 109 132 165 - - - -

c 51 57 66 70 90 - - - -

d 32 35 44 52 76 - - - -

e 96 110 127 157 210 - - - -

Page 220: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

Elbow & Union

EUX Union Series

Application

These Union are used ;

to installed in threaded thickwall conduit systems

to connect conduit to a conduit fitting, junction box or

device enclosure

to connect conduit to conduit, or to provide a means

for future modification of the conduit system

Compliance & Certification FeaturesIEC 60079-0, IEC 60079-1

ANSI/UL 886

Certified by UL (Underwriters Laboratories Inc.)

KOSHA (Korea Occupational Safety & Health Agency),

KGS (Korea Gas Safety Corporation), and the others.

compact design which permits assembly with a

minimum of clearance to other adjacent conduit

and/or equipment

strong and durable construction

UL Listed File No. E143517

Standard Materials

Body : Carbon Steel

Options Standard Finish NPT Thread : suffix. NPT

Zinc electro plated

◎ EUX Type of Explosion-proof

Flameproof ( Ex d IIC )

Class I Group C,D Class II Group E,F,G

Type Hub Size Cat. No.Dimen.

A B C

Female

1/2" 16C EUX 310 26 38 38

3/4" 22C EUX 311 31 44 41

1" 28C EUX 312 38 53 47

1-1/4" 36C EUX 313 48 65 53

1-1/2" 42C EUX 314 54 70 59

2" 54C EUX 315 69 80 63

2-1/2" 70C EUX 316 82 99 74

3" 82C EUX 317 95 111 82

3-1/2" 92C EUX 318 123 128 87

4" 104C EUX 319 121 140 105

Male

1/2" 16C EUX 320 35 38 55

3/4" 22C EUX 321 41 44 58

1" 28C EUX 322 50 53 67

1-1/4" 36C EUX 323 61 64 76

1-1/2" 42C EUX 324 67 70 83

2" 54C EUX 325 78 82 88

2-1/2" 70C EUX 326 97 101 105

3" 82C EUX 327 110 114 116

3-1/2" 92C EUX 328 123 128 123

4" 104C EUX 329 134 139 135

Page 221: Nb cat

SECTION - 3F

Flexible Coupling

Page 222: Nb cat

SECTION 3F

Flexible Coupling INDEXModel Product Description

Certification for

Explosion-proofPage

WPFC Weatherproof Flexible Coupling 3F - 1

EFCX Flameproof Flexible Coupling Ex d CⅡ 3F - 2

SPFC Increase-Safety Flexible Coupling Ex e Ⅱ 3F - 2

SEJ Expansion Joint 3F - 3

Page 223: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

Flexible Coupling

WPFC, EFCX, SPFC Series

< WPFC Weatherproof Type >

< EFCX Flameproof Type >

< SPFC Increase Safety Type >

Application Features

Cover openings on an angle, permitting conductors

to be pulled straight through either hub.

Taper tapped hubs and integral bushing for rigid

threaded conduit.

Maximum volume for bends within a compact

overall size.

Domed covers to permit easy conductor bends.

Screw on cover for ease of installation and

removal.

These Flexible Couplings are ;

where ignitable concentrations of flammable gases,

vapors or liquids can exist some of the time under

normal operation conditions.

Certification

Certified by KOSHA (Korea Occupational Safety &

Health Agency), KGS (Korea Gas Safety Corporation),

and the others.

Standard Finish Option

Zinc Electro Plated Chromate Finish

If you want another color, contact us please.

NPT Thread : suffix. NPT

Length : Contact us, please

(Standard is 500mm, 1000mm)

WPFC Weatherproof Type

Hub Size Cat No.Dimension Weight

( )㎏L A B

1/2" 16C WPFC 570 500

37 340.9

WPFC 580 1000 1.2

3/4" 22CWPFC 571 500

44 411.1

WPFC 581 1000 1.5

1" 28CWPFC 572 500

53 491.3

WPFC 582 1000 1.8

1-1/4" 36CWPFC 573 500

64 591.9

WPFC 583 1000 2.6

1-1/2" 42CWPFC 574 500

72 673.2

WPFC 584 1000 3.8

2" 54CWPFC 575 500

90 852.9

WPFC 585 1000 3.9

Standard Materials 2-1/2" 70CWPFC 576 500

107 993.8

WPFC 586 1000 4.9Flexible Tube : Plica Tube with PVC

covering

End Fitting : Brass

Finish : Zinc Electro Plated Chromate

Finish

3" 82CWPFC 577 500

116 1115.2

WPFC 587 1000 6.7

3-1/2" 92CWPFC 578 500 6.6

WPFC 588 1000 8.1

4" 104CWPFC 579 500

152 1468.0

WPFC 589 1000 9.5

* Length is order made, contact us please.

Page 224: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

EFCX Type of Explosion-proof

Flameproof ( Ex d IIC )

Hub Size Cat No.Dimension Weight

( )㎏L A B

1/2" 16C EFCX 1500 500

38 350.8

EFCX 1520 1000 1.0

3/4" 22CEFCX 1501 500

47 421.0

EFCX 1521 1000 1.3

1" 28CEFCX 1502 500

53 491.4

EFCX 1522 1000 1.8

1-1/4" 36CEFCX 1503 500

64 602.1

EFCX 1523 1000 2.6

1-1/2" 42CEFCX 1504 500

78 742.4

EFCX 1524 1000 3.2

2" 54CEFCX 1505 500

97 913.2

EFCX 1525 1000 5.3

Standard Materials 2-1/2" 70CEFCX 1506 500

113 1076.3

EFCX 1526 1000 7.4

Flexible Tube : Stainless Steel

End Fitting : Brass

Finish : Zinc Electro Plated Chromate

Finish

3" 82CEFCX 1507 500

122 1168.1

EFCX 1527 1000 12.2

3-1/2" 92CEFCX 1508 500 10.0

EFCX 1528 1000 15.2

4" 104CEFCX 1509 500

141 13512.2

EFCX 1529 1000 18.2

* Length is order made, contact us please.

SPFC Type of Explosion-proof

Increase Safety ( Ex e II )

Hub Size Cat No.Dimension Weight

( )㎏L A B

1/2" 16C SPFC 570 500

37 340.9

SPFC 580 1000 1.2

3/4" 22CSPFC 571 500

44 411.1

SPFC 581 1000 1.5

1" 28CSPFC 572 500

53 491.3

SPFC 582 1000 1.8

1-1/4" 36CSPFC 573 500

64 591.9

SPFC 583 1000 2.6

1-1/2" 42CSPFC 574 500

72 673.2

SPFC 584 1000 3.8

2" 54CSPFC 575 500

90 852.9

SPFC 585 1000 3.9

Standard Materials 2-1/2" 70CSPFC 576 500

107 993.8

SPFC 586 1000 4.9

Flexible Tube : Plica Tube with PVC

covering

End Fitting : Brass

Finish : Zinc Electro Plated Chromate

Finish

3" 82CSPFC 577 500

116 1115.2

SPFC 587 1000 6.7

3-1/2" 92CSPFC 578 500 6.6

SPFC 588 1000 8.1

4" 104CSPFC 579 500

152 1468.0

SPFC 589 1000 9.5

* Length is order made, contact us please.

Page 225: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

Expansion Joint

SEJ Series

Application

These SEJ Expansion Joints are used ;

in long conduit runs, to permit linear movement

caused by thermal expansion and contraction

in long conduit runs to prevent conduit from buckling

and circuit failures

FeaturesWeathertight construction

Insulator bushing on end of movable conduit.

Factory-formed fiberglass/ copper wire ring, lubricated

and graphited throughout for easy sliding of the

conduit in expansion and contraction.

Standard Materials

Body : Steel Conduit

Standard Finish

Zinc electro plated

◎ SEJ

Hub Size Cat. No.Max. Conduit

Movement

Min. Length

of Strap

Dimen.

A B C

1/2"

16C

SEJ 110 100 720 54 57 165

SEJ 210 200 920 54 57 265

3/4"

22C

SEJ 111 100 770 54 57 170

SEJ 211 200 970 54 57 270

1"

28C

SEJ 112 100 820 60 64 175

SEJ 212 200 1020 60 64 275

1-1/4"

36C

SEJ 113 100 870 62 78 180

SEJ 213 200 1070 62 78 280

1-1/2"

42C

SEJ 114 100 920 71 94 190

SEJ 214 200 1120 71 94 290

2"

54C

SEJ 115 100 1020 78 114 200

SEJ 215 200 1220 78 114 300

2-1/2"

70C

SEJ 116 100 1120 94 134 210

SEJ 216 200 1320 94 134 310

3"

82C

SEJ 117 100 1220 106 162 220

SEJ 217 200 1420 106 162 320

3-1/2"

92C

SEJ 118 100 1530 106 174 230

SEJ 218 200 1730 106 174 330

4"

104C

SEJ 119 100 1680 108 186 230

SEJ 219 200 1880 108 186 330

Page 226: Nb cat

SECTION - 4F

Sealing Fitting & Drain

Page 227: Nb cat

SECTION 4F

Sealing Fitting & Drain INDEX

Model Product DescriptionCertification for Explosion-proof

Page

IEC UL

EFZ Any Angle Type Sealing Fitting Ex d CⅡ 4F - 2

EFV Vertical Type Sealing Fitting Ex d CⅡ

Class I

Group C,D

Class II

Group E,F,G

4F - 2

EFVH Vertical or Horizontal Type Sealing Fitting Ex d CⅡ

Class I

Group C,D

Class II

Group E,F,G

4F - 2

EFVD Drain Sealing Fitting Ex d CⅡ 4F - 3

EDF Drain Sealing Fitting Ex d CⅡ 4F - 3

EFU Replace Type Sealing Fitting & Drain Ex d BⅡ 4F - 4

ECD 15 Universal Drain or Breather Ex d CⅡ 4F - 5

ECD 16 Breather Ex d CⅡ 4F - 5

ECD 17 Drain Ex d CⅡ 4F - 5

Page 228: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

Sealing Fitting & Drain

EFZ, EFV, EFVH, EFVD

Attention for Marking Seal Features

Do not splice any conductors in the sealing

fittings regardless the characteristics of the

sealing compound.

Make the sealing dam with the care using

the asbestos packing supplied with the

sealing compound. If the poured compound

leaks into the conduit, the quality of seal

would become insufficient, and it would be

a cause of trouble.

The sealing compound should be mixed with

water a little harder. Over addition of

solution or water may weaken the seal.

The sealing compound shall be poured so

as not to leave large bubbles in the seal.

The bubbles are come out by insufficient

fluidity and wrong pouring manner. For

removing bubbles, it is effective to pat the

sealing fitting gently just after the filling.

It is rather difficult to achieve good seal in

horizontal conduit run than in the vertical.

Therefore, when the any angle type sealing

fitting is used in horizontal conduit run, set

the cover with the filling opening at as high

position as possible, and pour the sealing

compound full.

EFV, EFVH Series Sealing Fittings are

minimum turning radius.

large openings with threaded closures to

provide easy access to conduit hubs for

making dams.

integral bushings in conduit hubs to

protect conductor insulation from damage.

taper-tapped hubs to insure ground

continuity.

EFZ Any Angle Type Sealing Fittings are

can be used for sealing horizontal, vertical

and other sloped conduit runs.

have large cover openings which provide

easy access to both hubs for making

sealing dam and pouring sealing

compound.

EFVD Series Drain Sealing Fittings are

drain to Provide continuous, automatic

drainage of condensate.

removable male nipple supplied when male

and female style is ordered.

Application

Sealing Fittings are used in;

restrict the passage of gases, vapors or

flames from one portion of the electrical

installation to another at atmospheric

pressure and normal ambient temperatures.

limit explosions to the sealed off enclosure.

prevent precompression or "pressure

piling" on conduit systems.

drain sealing fittings are installed in

vertical conduit runs and at low points in

conduit systems to prevent accumulation

of condensate above seal.

Compliance & CertificationIEC 60079-0, 1

ANSI/UL 886

UL Listed File No. E 143517 (EFV, EFVH

Series)

Certified by UL (Underwriters Laboratories

Inc.), KOSHA (Korea Occupational Safety

& Health Agency), KGS (Korea Gas Safety

Corporation), and the others.

Standard Finish

Hot Dip. Galvanized with stove enamelled

silver white

If you want another color, contact us

please.

Page 229: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

◎ EFZ Sealing Fitting Type of Explosion-proof Flameproof ( Ex d IIC )

Hub Size Cat. No.Dimen. ( )㎜

A B C D

1/2" 16C EFZ 300 100 42 48 83

3/4" 22C EFZ 301 105 42 48 88

1" 28C EFZ 302 110 42 48 98

1-1/4" 36C EFZ 303 125 58 67 113

1-1/2" 42C EFZ 304 130 58 67 119

2" 54C EFZ 305 180 58 67 131

2-1/2" 70C EFZ 306 200 77 84 156

3" 82C EFZ 307 215 77 84 170

3-1/2" 92C EFZ 308 235 90 110 185

4" 104C EFZ 309 245 90 110 210

Standard Materials Installation TypeCast Iron Any Angle Type

◎ EFV Sealing Fitting Type of Explosion-proof

Flameproof ( Ex d IIC )

Class I Group C,D Class II Group E,F,G

Flameproof EFV Sealing Fittings, Vertical type

Hub SizeCat. No. Dimen. ( )㎜

Female Male & Female A B C

1/2" 16C EFV 100 EFV 100M 108 32 70

3/4" 22C EFV 101 EFV 101M 114 36 73

1" 28C EFV 102 EFV 102M 128 43 84

1-1/4" 36C EFV 103 EFV 103M 150 53 104

1-1/2" 42C EFV 104 EFV 104M 170 60 116

2" 54C EFV 105 EFV 105M 200 74 141

2-1/2" 70C EFV 106 EFV 106M 220 90 167

3" 82C EFV 107 EFV 107M 250 106 201

3-1/2" 92C EFV 108 EFV 108M - - -

4" 104C EFV 109 EFV 109M 286 132 237

Flameproof EFVH Sealing Fittings, Horizontal type

Hub SizeCat. No. Dimen. ( )㎜

Female Male & Female A B C

1/2" 16C EFVH 100 EFVH 100M 90 32 46

3/4" 22C EFVH 101 EFVH 101M 110 36 60

1" 28C EFVH 102 EFVH 102M 120 43 70

1-1/4" 36C EFVH 103 EFVH 103M 130 53 80

1-1/2" 42C EFVH 104 EFVH 104M 144 60 88

2" 54C EFVH 105 EFVH 105M 165 74 103

2-1/2" 70C EFVH 106 EFVH 106M 200 90 116

3" 82C EFVH 107 EFVH 107M 215 106 138

3-1/2" 92C EFVH 108 EFVH 108M - - -

4" 104C EFVH 109 EFVH 109M 245 132 160

Standard Materials FinishesCast Iron Hot Dip Galvanize with stove enamelled silver

Page 230: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

◎ EFVD Drain Sealing Fitting Type of Explosion-proof

Flameproof ( Ex d IIC )

Hub SizeCat. No. Dimen. ( )㎜

Female Male & Female A B C D

1/2" 16C EFVD 816 EFVD 816M 83 32 62 57

3/4" 22C EFVD 822 EFVD 822M 94 36 66 66

1" 28C EFVD 828 EFVD 828M 110 43 75 78

1-1/4" 36C EFVD 836 EFVD 836M 130 53 80 101

1-1/2" 42C EFVD 842 EFVD 842M 144 60 88 105

2" 54C EFVD 854 EFVD 854M 165 74 103 125

2-1/2" 70C EFVD 870 EFVD 870M 200 90 116 139

3" 82C EFVD 882 EFVD 882M 215 106 138 163

3-1/2" 92C EFVD 892 EFVD 892M - - - -

4" 104C EFVD 8104 EFVD 8104M 245 132 160 189

Standard MaterialsBody : Cast Iron

Drain : Stainless steel

Removable Nipple : Steel

◎ EDF Drain Sealing Fitting Type of Explosion-proof

Flameproof ( Ex d IIC )

Hub Size Cat. No.Dimen. ( )㎜

A B C D

1/2" 16C EDF 900 115 85 85 70

3/4" 22C EDF 901 115 90 85 70

1" 28C EDF 902 135 105 90 80

1-1/4" 36C EDF 903 135 115 90 80

1-1/2" 42C EDF 904 150 120 100 95

2" 54C EDF 905 170 130 100 95

2-1/2" 70C EDF 906 200 140 100 95

3" 82C EDF 907 215 153 100 95

3-1/2" 92C EDF 908 235 168 100 95

4" 104C EDF 909 245 181 100 95

Standard MaterialsBody : Cast Iron

Drain : Stainless steel

Removable Nipple : Steel

Sealing Compound Required (g)

Hub Size 1/2" 16C 3/4" 22C 1" 28C 1-1/4" 36C 1-1/2" 42C 2" 54C 2-1/2" 70C 3" 82C 3-1/2" 92C 4" 104C

EDF 120 140 210 260 300 430 500 600 800 1,000

EFZ 90 110 130 220 270 440 800 1,050 1,600 2,000

Page 231: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

Retrofit Sealing Fitting & Drain

EFU Series

Type of Explosion-proof

Flameproof (Ex d IIB)

Application

EFU Series retrofit sealing fittings are installed;

in rigid metal conduit systems in hazardous locations.

to replace installed EFV type sealing fittings.

without disassembly of the conduit system.

in vertical or horizontal positions, indoors or outdoors.

to restrict the passage of gases, vapors or flames from

one portion of the electrical system to another at

atmospheric pressures and normal ambient

temperatures.

to limit explosions to the sealed-off enclosure.

to limit precompression or "pressure piling" in the

conduit system.

Features Standard Materials

Seal may be installed in the existing conduit run without disassembly of the conduit system saving time and labor.Overall length and spacing requirements do not exceed those of standard EFV seals; permits close nesting of seals.Pipe plugs permit the installation of a standard EFVD drain fitting for use in vertical conduit runs to drain any water that might accumulate in the conduits system.Steel set screws provide grounding continuity.Suitable for vertical and horizontal installations for indoor and outdoor applications.Available in 3/4" to 4" NPT size.

Enclosure : Cast Iron

Pipe plugs, bolts and set screws : Steel

Gasket : Neoprene

Compliance & Certification

IEC 60079-0, 1Certified by UL (Underwriters Laboratories Inc.)

Certified by KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others.

Standard Finish

Cast Iron :

Electrogalvanized and Aluminium acrylic paint

Steel : Electrogalvanized

Gasket : Natural

If you want another color, contact us please.

Entry Size

3/4"(22C) ~ 4“(104C)

Ordering Number

Hub

Size

Cat

No

Internal Volume

(cm3)

Amount of Fiber

per Hub (g)Dimension (mm)

Vert. Horz. Vert. Horz. A B C

3/4" EFU1 57.2 94 1.8 3.5 93 64 38

1" EFU2 77.6 155 3.5 7 111 79 79

1-1/4" EFU3 114 220 7 14 127 85 76

1-1/2" EFU4 200 396 14 28.3 133 92 76

2" EFU5 420 661 28.3 56.6 158 101 76

2-1/2" EFU6 784 1,233 42.5 85 190 127 98

3" EFU7 1,413 2,059 56.6 113 216 139 108

3-1/2" EFU8 2,402 3,431 127 254 233 154 120

4" EFU9 3,039 4,117 127 254 247 168 133

If you need more information, contact us please. ⇨

Page 232: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

Drain & Breather

ECD Series

Type of Explosion-proof Flameproof (Ex d IIC)

Male

Threaded

Size

Drain and Breather

"Universal"

Drain or

Breather

Breather for

Air only

Drain for

Water only

Catalog Number16 ½" ECD 15 ECD 16 ECD 17

Application Features ECD drains and breathers are installed in enclosures or

conduit systems to ;

provide ventilation to minimize.

condensation.

drain accumulated condensate.

at least one breather should be used with such

drain.

A "standard" drain is installed in bottom of enclosure

or in lower section of conduit system.

Universal "breather or drain functions as breathe

when mounted at the top of an enclosure, or as a

drain when mounted in be bottom of an enclosure".

drains and breathers are installed in hubs drilled and

tapped openings.

"Universal" ECD drains and breathers have :

Patented labyrinth design, suitable for use in Class , Ⅰ

Division 1 & 2, Groups C,D and Class , Division 1 & Ⅱ

2, Groups F,G areas.

Capability to pass 50 cc of water per minute and 0.2

cubic feet or air per minute at atmospheric pressure.

ECD15 have a well inside the inner, threaded end to

provide for accumulation of sediment without clogging

when used as a drain.

"Standard" ECD drains and breathers have:

thread-in-thread design, suitable for use in Class , Ⅰ

Division 1 & 2, Groups C,D and Class , Division 1, Ⅱ

Groups E,F,G; Class , Division 2, Groups F,G and Ⅱ

Class areas.Ⅲ

ECD 16, 17 are thread0in-thread design for use in

Class , Division 1 & 2, Groups B,C,D; Class , Ⅰ Ⅱ

Division 1, Groups E,F,G; Class , Division 2, Groups Ⅱ

F,G and Class areas.Ⅲ

They have the capability to pass 0.1 cubic feet of air

per minute and 0.5cc of water per minute.

Standard Materials Standard Finish

ECD 15 : Stainless steel

ECD 16, 17 : Brass (Stainless steel is order made.)

Natural

If you want another color, contact us please.

If you need more information, contact us please. ⇨

Page 233: Nb cat

SECTION - 5F

Cable Gland

Page 234: Nb cat

SECTION 5F

Cable Gland INDEX

Model

Gland Type

Certification for

Explosion-proofPage

Cable Type Seal For

SWA STALead

CoveredSWA

UnArmoured

Not Seal

Outer only

Outer +

Inner

Indoor

Outdoor

Zone 1 & 2

E1FW ● ● ● ● ●Ex d CⅡ

Ex e Ⅱ5F - 2

E1W ● ● ● ● 5F - 2

E2FW ● ● ● ● ●Ex d CⅡ

Ex e Ⅱ5F - 3

E2W ● ● ● ● 5F - 3

CW ● ● 5F - 4

BW ● ● 5F - 4

A2F ● ● ● ● ●Ex d CⅡ

Ex e Ⅱ5F - 5

A2 ● ● ● ● 5F - 5

A4e ● ● ● ● ● Ex e Ⅱ 5F - 6

A4 ● ● ● ● 5F - 6

Acces

soryCable Gland Accessories 5F - 7

EG Conduit Fittings Packing Cable Gland

Ex d IIC

5F - 8

EGC Conduit Fittings Packing Cable Gland 5F - 9

EPG Conduit Fittings Packing Cable Gland 5F - 9

EUG Conduit Fittings Packing Cable Gland 5F - 9

Page 235: Nb cat

NAMBUK Cable Gland

Copyright by NAMBUK Electric Co., LTD. 2008

Armoured / Un-armoured Cable Gland

Application

These cable glands are used ;

suited to armoured/un-armoured cables used mainly in

areas where British Standards apply.

particularly suited to Steel Wire Armoured Cable.

compliance to BS 6121:1989.

available in standard industrial or explosion protected

designs for "Ex" equipment in both "flameproof" and

"increased" enclosures (E1FW, E2FW, A2F).

compliance to IEC 60079-0, 60079-1 and 60079-7,

60079-14, EN 50014, 50018 and 50019 (E1FW, E2FW,

A2F).

can be used in Zone 1 and Zone 2 (E1FW, E2FW, A2F)

degree of protection max. IP66.

available in metric and NPT inlet threads.

Operating Temperature : -20 ~ +80℃ ℃

Features Standard Materials

2 or 3 part armour / earth lock.

Knurled armour lock produces a low resistance earth

clamp.

Inner and outer displacement seal.

Gland entry rated at IP66 with NAMBUK entry thread

seal.

Easy and fast to install.

Displacement seal concept ensures effective seal to

inner and outer sheath.

Displacement seals suited to most hostile environments.

Body : Brass, Aluminium

Lock Nut : Brass, Aluminium

Earth Tag : Brass

Metric Entry Thread Seal : Nylon

Shroud : PVC / LSF

Options

Combination concept

Alternative materials / plating

Cast integral earth lug

Entry thread : NPT, PF, NPS, PG and the others

EeCFC Seal for cable exhibit "cold flow" characteristicsStandard Finish

Natural / Nickel Plated

If you want another finish, contact us please.

Degree of Protection

Gland TypeEntry thread PVC shroud and entry thread

with seal without seal with seal without seal

E1FW, E1W, E2FW, E2W, A2F, A2, A4e, A4, CW IP 66 IP 54 IP 66 IP 54

Gland Selection Entry Thread

Gland Type E1FW E1W E2FW E2W BW CW A2 A2F A4 A4e Size Metric NPT PG PF

Cable

Type

SWA ◆ ◆ ◆ ◆ ◆ 20/16 20 1/2" 11 1/2"

STA ◆ ◆ 20S 20 1/2" 13.5 1/2"

SWA Lead Sheathed ◆ ◆ 20 20 1/2", 3/4" 16 1/2", 3/4"

Un-armoured ◆ ◆ 25 25 3/4", 1" 21 3/4", 1"

Seal

Not Seal ◆ 32 32 1", 1-1/4" 29 1", 1-1/4"

Outer only ◆ ◆ ◆ ◆ ◆ 40 40 1-1/4", 1-1/2" 36 1-1/4", 1-1/2"

Outer + Inner ◆ ◆ ◆ ◆ 50S 50 1-1/2" 36 1-1/2"

For

Indoor ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ 50 50 2" 42 2"

Outdoor ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ 63S 63 2“ 48 2“

Zone 1 & 2 ◆ ◆ ◆ ◆ 63 63 2-1/2" - 2-1/2"

75S 75 2-1/2" - 2-1/2"1) Check conditions of use (i.e. industrial, Ex d, etc)

75 75 3“ - 2-1/2" or 3“2) Check cable external diameter90 90 3-1/2“ - 3" or 3-1/2“3) Check cable under-armour diameter

4) Check type of armour and thickness

5) Check accessories (i.e. shrouds, earth tags etc) If you need more data, contact us please. ⇨

Page 236: Nb cat

NAMBUK Cable Gland

Copyright by NAMBUK Electric Co., LTD. 2008

Armoured Cable Gland

for SWA Cable,

Explosion-proof Type

Type of Explosion-proof Flameproof ( Ex d IIC )

Increase Safety ( Ex e II )

Certificate No : PTB No. Ex - 05 IEC 1005X

Technical Data

Type E1FW Cable Type Steel Wire Armour

GlandMaterial Brass Sealing

Area Inner & Outer Sheath

SealMaterial

Thermoplastic Elastomer For Area

Indoor Outdoor

Hazardous Area

Ordering Number & Dimension Accessory

Cable

Gland

Size

Entry Thread 'C' Thread

Length

'D'

Cable Dimensions Armour

Wire Dia

(SWA)

Max

Dia

'E'

Shrouds, Earth Tags,

Locknuts, Metric Entry Thread

Seals - see accessory page.Metric NPT PF

Cable Dia 'A'

Min Max

Cable Dia 'B'

Min Max

20/16 20 1/2" 1/2" 18 3.0 - 8.6 14.0 - 14.0 0.9 25

20S 20 1/2" 1/2" 18 6.0 - 11.6 14.0 - 15.9 0.9/1.25 31

Option20 20 1/2" 1/2" 18 8.0 - 13.9 14.0 - 20.9 0.9/1.25 34

25 25 3/4" 3/4" 20 13.0 - 19.9 18.1 - 26.2 1.25/1.6 44 Can choice EeCFC Seal

instead of standard seal

when use with certain cable

type that exhibit "cold flow"

characteristics

32 32 1" 1" 23 17.0 - 26.2 24.3 - 33.9 1.6/2 53

40 40 1-1/4" 1-1/4" 23 24.0 - 32.1 28.0 - 40.4 1.6/2 61

50S 50 1-1/2" 1-1/2" 23 30.0 - 38.1 38.0 - 46.7 2/2.5 67

50 50 2" 2" 25 36.0 - 44.0 43.0 - 53.1 2/2.5 78

63S 63 2“ 2“ 25 42.0 - 49.9 48.6 - 59.4 2.5 80

63 63 2-1/2" 2-1/2" 30 48.0 - 55.9 56.2 - 65.9 2.5 88

75S 75 2-1/2" 2-1/2" 30 52.8 - 61.9 60.2 - 72.1 2.5 104

75 75 3“ 2-1/2" 30 55.0 - 64.0 61.0 - 78.5 2.5/3.15 110

90 90 3“ 3" 30 68.0 - 79.3 81.4 - 90.4 3.15 127

Armoured Cable Gland

for SWA Cable, General or Regular Type

Technical Data

Type E1W Cable Type Steel Wire Armour

Gland

MaterialBrass

Sealing

AreaInner & Outer Sheath

Seal

MaterialThermoplastic

Elastomer For AreaIndoor

Outdoor

Ordering Number & Dimension Accessory

Cable

Gland

Size

Entry Thread 'C' Thread

Length

'D'

Cable Dimensions Armour

Wire Dia

(SWA)

Max

Dia

'E'

Shrouds, Earth Tags,

Locknuts, Metric Entry

Thread Seals - see

accessory page.

Metric NPT PFCable Dia 'A'

Min Max

Cable Dia 'B'

Min Max20/16 20 1/2" 1/2" 18 3.0 - 8.6 14.0 - 14.0 0.9 25

20S 20 1/2" 1/2" 18 6.0 - 11.6 14.0 - 15.9 0.9/1.25 31

20 20 1/2" 1/2" 18 8.0 - 13.9 14.0 - 20.9 0.9/1.25 34

25 25 3/4" 3/4" 20 13.0 - 19.9 18.1 - 26.2 1.25/1.6 44

Option32 32 1" 1" 23 17.0 - 26.2 24.3 - 33.9 1.6/2 53

40 40 1-1/4" 1-1/4" 23 24.0 - 32.1 28.0 - 40.4 1.6/2 61 Can choice EeCFC Seal

instead of standard seal

when use with certain

cable type that exhibit

"cold flow" characteristics

50S 50 1-1/2" 1-1/2" 23 30.0 - 38.1 38.0 - 46.7 2/2.5 67

50 50 2" 2" 25 36.0 - 44.0 43.0 - 53.1 2/2.5 78

63S 63 2“ 2“ 25 42.0 - 49.9 48.6 - 59.4 2.5 80

63 63 2-1/2" 2-1/2" 30 48.0 - 55.9 56.2 - 65.9 2.5 88

75S 75 2-1/2" 2-1/2" 30 52.8 - 61.9 60.2 - 72.1 2.5 104

75 75 3“ 2-1/2" 30 55.0 - 64.0 61.0 - 78.5 2.5/3.15 110

90 90 3“ 3“ 30 68.0 - 79.3 81.4 - 90.4 3.15 127

Page 237: Nb cat

NAMBUK Cable Gland

Copyright by NAMBUK Electric Co., LTD. 2008

Armoured Cable Gland

for SWA Cable,

Explosion-proof Type

Type of Explosion-proof Flameproof (Ex d IIC)

Increase Safety (Ex e II)

Certificate No : PTB No. Ex - 07 IEC 1007X

Technical Data

Type E2FW Cable Type Lead Covered

Steel Wire Armour

Gland

MaterialBrass

Sealing

AreaInner & Outer Sheath

Seal

MaterialThermoplastic

Elastomer For Area

Indoor

Outdoor

Hazardous Area

Ordering Number & Dimension Accessory

Cable

Gland

Size

Entry Thread 'C' Thread

Length

'D'

Cable Dimensions Armour

Wire Dia

(SWA)

Max Dia

'E'

Shrouds, Earth Tags,

Locknuts, Metric Entry

Thread Seals - see

accessory page.

Metric NPT PFCable Dia 'A'

Min Max

Cable Dia 'B'

Min Max20S 20 1/2" 1/2" 18 6.6 - 11.6 14.0 - 15.9 0.9/1.25 31

20 20 1/2" 1/2" 18 8.0 - 13.9 14.0 - 20.9 0.9/1.25 34

25 25 3/4" 3/4" 20 13.0 - 19.9 22.8 - 26.2 1.25/1.6 44

32 32 1" 1" 23 17.0 - 26.2 24.0 - 33.9 1.6/2 53

40 40 1-1/4" 1-1/4" 23 24.0 - 32.1 30.0 - 40.4 1.6/2 61

50S 50 1-1/2" 1-1/2" 23 30.0 - 38.1 37.5 - 46.7 2/2.5 67

50 50 2" 2" 25 36.0 - 44.0 43.5 - 53.1 2/2.5 78

63S 63 2“ 2“ 25 42.0 - 49.9 49.5 - 59.4 2.5 80

63 63 2-1/2" 2-1/2" 30 48.0 - 55.9 56.5 - 65.9 2.5 88

75S 75 2-1/2" 2-1/2" 30 52.8 - 61.9 56.5 - 72.1 2.5 104

75 75 3“ 2-1/2" 30 57.0 - 64.0 61.0 - 78.5 2.5/3.15 110

90 90 3“ 3“ 30 69.0 - 79.3 78.0 - 90.4 3.15 127

Armoured Cable Gland

for SWA Cable, General or Regular Type

Technical Data

Type E2W Cable Type Steel Wire Armour

Gland

MaterialBrass

Sealing

AreaInner & Outer Sheath

Seal

MaterialThermoplastic

Elastomer For AreaIndoor

Outdoor

Ordering Number & Dimension Accessory

Cable

Gland

Size

Entry Thread 'C' Thread

Length

'D'

Cable Dimensions Armour

Wire Dia

(SWA)

Max Dia

'E'Shrouds, Earth Tags,

Locknuts, Metric Entry

Thread Seals - see

accessory page.

Metric NPT PFCable Dia 'A'

Min Max

Cable Dia 'B'

Min Max20S 20 1/2" 1/2" 18 6.6 - 11.6 14.0 - 15.9 0.9/1.25 31

20 20 1/2" 1/2" 18 8.0 - 13.9 14.0 - 20.9 0.9/1.25 34

25 25 3/4" 3/4" 20 13.0 - 19.9 22.8 - 26.2 1.25/1.6 44

32 32 1" 1" 23 17.0 - 26.2 24.0 - 33.9 1.6/2 53

40 40 1-1/4" 1-1/4" 23 24.0 - 32.1 30.0 - 40.4 1.6/2 61

50S 50 1-1/2" 1-1/2" 23 30.0 - 38.1 37.5 - 46.7 2/2.5 67

50 50 2" 2" 25 36.0 - 44.0 43.5 - 53.1 2/2.5 78

63S 63 2“ 2“ 25 42.0 - 49.9 49.5 - 59.4 2.5 80

63 63 2-1/2" 2-1/2" 30 48.0 - 55.9 56.5 - 65.9 2.5 88

75S 75 2-1/2" 2-1/2" 30 52.8 - 61.9 56.5 - 72.1 2.5 104

75 75 3“ 2-1/2" 30 57.0 - 64.0 61.0 - 78.5 2.5/3.15 110

90 90 3“ 3“ 30 69.0 - 79.3 78.0 - 90.4 3.15 127

Page 238: Nb cat

NAMBUK Cable Gland

Copyright by NAMBUK Electric Co., LTD. 2008

Armoured Cable Gland

for SWA Cable, General or Regular Type

Technical Data

Type CW Cable Type Steel Wire Armour

Gland

Material Brass

Sealing

AreaInner & Outer Sheath

Seal

MaterialThermoplastic

Elastomer For AreaIndoor

Outdoor

Ordering Number & Dimension Accessory

Cable

Gland

Size

Entry Thread 'C' Thread

Length

'D'

Cable Dimensions Armour

Wire Dia

(SWA)

Max Dia

'E'

Shrouds, Earth Tags,

Locknuts, Entry

Thread Seals - see

accessory page.

Metric NPT PFCable Dia 'A'

Max

Cable Dia 'B'

Min Max

20/16 20 1/2" 1/2" 15 8.6 6.0 - 13.4 0.9 24.4

20S 20 1/2" 1/2" 10 11.6 9.5 - 15.9 0.9/1.25 26.6

20 20 1/2" 1/2" 10 13.9 12.5 - 20.9 0.9/1.25 33.3

25 25 3/4" 3/4" 10 19.9 17.0 - 26.2 1.25/1.6 40.5

32 32 1" 1" 10 26.2 22.9 - 33.9 1.6/2 51.0

40 40 1-1/4" 1-1/4" 15 32.1 26.0 - 40.4 1.6/2 61.0

50S 50 1-1/2" 1-1/2" 15 38.1 35.0 - 46.7 2/2.5 66.5

50 50 2" 2" 15 44.0 38.0 - 53.1 2/2.5 77.7

63S 63 2“ 2“ 15 50.0 45.6 - 59.4 2.5 83.2

63 63 2-1/2" 2-1/2" 15 55.9 54.6 - 65.9 2.5 88.7

75S 75 2-1/2" 2-1/2" 15 61.9 57.0 - 72.1 2.5 101.6

75 75 3“ 2-1/2" 15 67.9 60.4 - 78.5 2.5/3.15 111.1

90 90 3“ 3“ 15 79.3 69.2 - 90.4 3.15 128.6

Armoured Cable Gland

for SWA Cable, General or Regular Type

Technical Data

Type BW Cable Type Steel Wire Armour

Gland Material Brass For Area Indoor

Ordering Number & Dimension Accessory

Cable

Gland

Size

Metric

Entry Thread 'C'

Thread

Length

'D'

Cable Dimensions Armour

Wire Dia

(SWA)

Max Dia

'E'

Shrouds, Earth Tags,

Locknuts, Serrated

Washer - see

accessory page.

Cable Dia 'A'

Max

Cable Dia 'B'

Max

20S 20 10 11.6 16.1 0.9/1.25 24.0

20 20 10 13.9 21.1 0.9/1.25 30.0

25 25 10 19.9 27.4 1.25/1.6 36.0

32 32 10 26.2 34.4 1.6/2 44.5

40 40 15 32.1 42.4 1.6/2 56.3

50S 50 15 38.1 50.1 2/2.5 63.4

50 50 15 44.0 55.7 2/2.5 72.1

63S 63 15 50.0 62.4 2.5 83.0

63 63 15 55.9 68.2 2.5 88.7

75S 75 15 61.9 76.8 2.5 99.8

75 75 15 67.9 82.9 2.5/3.15 105.3

Page 239: Nb cat

NAMBUK Cable Gland

Copyright by NAMBUK Electric Co., LTD. 2008

Unarmoured Cable Gland

Explosion-proof Type

Type of Explosion-proof Flameproof (Ex d IIC)

Increase Safety (Ex e II)

Certificate No : PTB No. Ex - 07 IEC 1067X

Technical Data

Type A2F Cable Type Unarmoured

Gland

MaterialBrass

Sealing

AreaOuter Sheath

Seal

MaterialThermoplastic

Elastomer For Area

Indoor

Outdoor

Hazardous Area

Ordering Number & Dimension Accessory

Cable

Gland

Size

Entry Thread 'B'Thread

Length 'C'

Cable Dia 'A'

Min Max

Max Dia

'D'Shrouds, Earth Tags,

Locknuts, Entry

Thread Seals - see

accessory page.

Metric NPT PF

20/16 20 1/2" 1/2" 17 3.0 - 8.0 26

20S 20 1/2" 1/2" 17 6.0 - 11.5 32.5

20 20 1/2" 1/2" 17 11.0 - 13.5 32.5

25 25 3/4" 3/4" 20 13.2 - 19.5 41

32 32 1" 1" 23 17.0 - 25.5 55

40 40 1-1/4" 1-1/4" 23 22.3 - 32.0 60

50S 50 1-1/2" 1-1/2" 24 31.6 - 37.0 70

50 50 2" 2" 26 35.7 - 43.0 86

63S 63 2“ 2“ 26 40.3 - 50.0 86

63 63 2-1/2" 2-1/2" 30 47.3 - 55.0 97

75S 75 2-1/2" 2-1/2" 30 53.0 - 61.0 97

75 75 3“ 2-1/2" 30 60.5 - 67.0 109

90 90 3“ 3“ 30 66.7 - 79.0 120

Unarmoured Cable Gland

General or Regular Type

Technical Data

Type A2 Cable Type Unarmoured

Gland

MaterialBrass

Sealing

AreaOuter Sheath

Seal

MaterialThermoplastic

Elastomer For AreaIndoor

Outdoor

Ordering Number & Dimension Accessory

Cable

Gland

Size

Entry Thread 'B'Thread

Length 'C'

Cable Dia 'A'

Min Max

Max Dia

'D'Shrouds, Earth Tags,

Locknuts, Entry

Thread Seals - see

accessory page.

Metric NPT PF

20/16 20 1/2" 1/2" 17 3.0 - 8.0 26

20S 20 1/2" 1/2" 17 6.0 - 11.5 32.5

20 20 1/2" 1/2" 17 11.0 - 13.5 32.5

25 25 3/4" 3/4" 20 13.2 - 19.5 41

32 32 1" 1" 23 17.0 - 25.5 55

40 40 1-1/4" 1-1/4" 23 22.3 - 32.0 60

50S 50 1-1/2" 1-1/2" 24 31.6 - 37.0 70

50 50 2" 2" 26 35.7 - 43.0 86

63S 63 2“ 2“ 26 40.3 - 50.0 86

63 63 2-1/2" 2-1/2" 30 47.3 - 55.0 97

75S 75 2-1/2" 2-1/2" 30 53.0 - 61.0 97

75 75 3“ 2-1/2" 30 60.5 - 67.0 109

90 90 3“ 3“ 30 66.7 - 79.0 120

Page 240: Nb cat

NAMBUK Cable Gland

Copyright by NAMBUK Electric Co., LTD. 2008

Armoured Cable Gland

Increase Safety Type

Type of Explosion-proof

Increase Safety (Ex e II)

Technical Data

Type A4e Cable Type Steel Tape Armoured

Gland

MaterialBrass

Sealing

AreaOuter Sheath

Seal

MaterialThermoplastic

Elastomer For Area

Indoor

Outdoor

Hazardous Area

Ordering Number & Dimension Accessory

Cable

Gland

Size

Entry Thread 'C'Thread

Length 'D'

Cable Dia 'A'

Min Max

Cable Dia 'B'

Min Max

Max Dia

'E' Shrouds, Earth Tags,

Locknuts, Entry

Thread Seals - see

accessory page.

Metric NPT PF

20S 20 1/2" 1/2" 15 6.5 - 11.6 6.1 - 11.6 26.5

20 20 1/2" 1/2" 15 10.0 - 13.9 6.5 - 13.9 30.0

25 25 3/4" 3/4" 15 11.6 - 19.9 11.1 - 19.9 39.9

32 32 1" 1" 15 19.0 - 26.2 17.0 - 26.2 45.5

40 40 1-1/4" 1-1/4" 15 25.0 - 32.1 22.0 - 32.1 55.4

50S 50 1-1/2" 1-1/2" 15 27.5 - 38.1 29.5 - 38.1 61.0

50 50 2" 2" 15 33.1 - 44.0 35.6 - 44.0 66.5

63S 63 2“ 2“ 15 40.1 - 50.0 40.1 - 49.9 77.6

63 63 2-1/2" 2-1/2" 15 47.2 - 55.9 47.2 - 55.9 83.2

75S 75 2-1/2" 2-1/2" 15 43.5 - 61.9 52.8 - 61.9 88.7

75 75 3“ 2-1/2" 15 49.8 - 67.9 59.1 - 67.9 94.2

90 90 3“ 3“ 15 64.0 - 79.3 66.6 - 79.3 120.7

Armoured Cable Gland

General or Regular Type

Technical Data

Type A4 Cable Type Steel Tape Armoured

Gland

MaterialBrass

Sealing

AreaOuter Sheath

Seal

MaterialThermoplastic

Elastomer For AreaIndoor

Outdoor

Ordering Number & Dimension Accessory

Cable

Gland

Size

Entry Thread 'C'Thread

Length 'D'

Cable Dia 'A'

Min Max

Cable Dia 'B'

Min Max

Max Dia

'E' Shrouds, Earth Tags,

Locknuts, Entry

Thread Seals - see

accessory page.

Metric NPT PF

20S 20 1/2" 1/2" 15 6.5 - 11.6 6.1 - 11.6 26.5

20 20 1/2" 1/2" 15 10.0 - 13.9 6.5 - 13.9 30.0

25 25 3/4" 3/4" 15 11.6 - 19.9 11.1 - 19.9 39.9

32 32 1" 1" 15 19.0 - 26.2 17.0 - 26.2 45.5

40 40 1-1/4" 1-1/4" 15 25.0 - 32.1 22.0 - 32.1 55.4

50S 50 1-1/2" 1-1/2" 15 27.5 - 38.1 29.5 - 38.1 61.0

50 50 2" 2" 15 33.1 - 44.0 35.6 - 44.0 66.5

63S 63 2“ 2“ 15 40.1 - 50.0 40.1 - 49.9 77.6

63 63 2-1/2" 2-1/2" 15 47.2 - 55.9 47.2 - 55.9 83.2

75S 75 2-1/2" 2-1/2" 15 43.5 - 61.9 52.8 - 61.9 88.7

75 75 3“ 2-1/2" 15 49.8 - 67.9 59.1 - 67.9 94.2

90 90 3“ 3“ 15 64.0 - 79.3 66.6 - 79.3 120.7

Page 241: Nb cat

NAMBUK Cable Gland

Copyright by NAMBUK Electric Co., LTD. 2008

Accessories / Option for Cable Gland

Shroud (PVC / LSF) Earth TagsShroud totally encloses the gland

body and forms an effective seal

down onto the cables's overall

The shroud has an extensive

taper at the cable end and

effectively seals the smallest size

of cable.

The shroud forms a protective

seal to the exposed metal parts

of the gland when used in highly

corrosive atmospheres.

Standard material is PVC

The earth tag which fits onto the thread

at the terminal end is manufactured from

brass strip 1.6mm thick

By including this earth tag, a more

effective bearing surface is presented to

the apparatus or other conducting parts.

The earth tag provide and earth bond

connection as specified in BS 6121:Pt5.

Earth bond connections are specified in

IEE wiring regulations and relevant

Codes of Practice. If fault current rating

of the cable exceeds the short circuit

rating specified in the table below, an

integral earth gland is recommended.

Metric Entry Thread Seals Earth

Tag

Size

Short Circuit Rating Symmetrical Fault

Current (kA) for 1sFor IP rating across the interface

between the equipment and

gland, it is essential to fit a

metric entry thread seal.

Standard material is nylon.

Standard High Breaking Capacity

20 3.06 4.4

25 4.00 4.8

32 5.40 5.2

EeCFC Seal 40 7.20 9.8

50 10.40 11.4For inner seal use with cable

certain exhibit "cold flow"

characteristics

63 10.40 12.0

75 10.40 14.3

LocknutAvailable to suit all thread forms

offered with cable glands.

Standard material is brass

Zinc plated mild steel locknuts are a

cost effective alternative to the brass

locknuts, but be used only in dry, low

humidity conditions.

Earth Washer (Serrated Type)For Lead Covered Steel Wire

Armoured Cable

Cold Flow

The latest IEC 60079 requires that certain cable types which employ materials which can exhibit significant "cold flow"

characteristics which could have adverse effects on the protection of the apparatus, is to be used, a suitable cable entry

device should be employed. "EeCFC Seal" is to avoid this problem designed that eliminating any damage to the cable

sheath as opposed to conventional compression seal which usually require the cable gland to be fully tightened on

installation.

<Compression Type Seal> <Reduce Damage Type Seal>

If you need more information, contact us please. ⇨

Page 242: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

Conduit Fittings

Packing Cable Gland Type of Explosion-proof

Flameproof ( Ex d IIC )

<EG>

<EGC>

<EPG>

<EUG>

Application

These cable glands are ;

EPG is designed to provide flameproof packing type

cable gland for corrugated steel armoured cable

EUG is fit to the threaded conduit entries and used

for the purpose of leading the unarmoured cable at

open area.

Available in metric and NPT inlet threadsFeatures

Compact size for close nesting of cables.

Easy and fast to install

Hex design for easy wrenching

Compliance & Certification

IEC 60079-0, 1

Certified by KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others.

◎ EG

Hub Size Cable Size Cat No. A B C D

1/2" 16C 7- 09∅ ∅ EG 16-9

1/2" 42 97 409- 12∅ ∅ EG 16-12

3/4" 22C 11- 14∅ ∅ EG 22-14 3/4" 49 104 44

1" 28C 14- 19∅ ∅ EG 28-19 1" 59 110 48

1-1/4" 36C 19- 24∅ ∅ EG 36-24 1-1/4" 76 147 62

1-1/2" 42C 24- 28∅ ∅ EG 42-28 1-1/2" 88 156 71

2" 54C 28- 33∅ ∅ EG 54-33 2" 102 182 87

2-1/2" 70C33- 39∅ ∅ EG 70-39

2-1/2" 122 200 103Standard Materials 39- 44∅ ∅ EG 70-44

Die Cast Aluminium3" 82C

44- 49∅ ∅ EG 82-493" 142 225 117

49- 54∅ ∅ EG 82-54Standard Finish 4" 104C 54- 69∅ ∅ EG 104-69 4" 182 264 149Stove enamelled grayish blue

If you want another color, contact us

please.

Page 243: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

◎ EGC

Hub Size Cable Size Cat No. A B C D

1/2" 16C 07- 09∅ ∅ EGC 16-9

1/2" 42 97 4009- 12∅ ∅ EGC 16-12

3/4" 22C 11- 14∅ ∅ EGC 22-14 3/4" 49 104 44

1" 28C 14- 19∅ ∅ EGC 28-19 1" 59 110 48

1-1/4" 36C 19- 24∅ ∅ EGC 36-24 1-1/4" 76 147 62

1-1/2" 42C 24- 28∅ ∅ EGC 42-28 1-1/2" 88 156 71

2" 54C 28- 33∅ ∅ EGC 54-33 2" 102 182 87

2-1/2" 70C33- 39∅ ∅ EGC 70-39

2-1/2" 122 200 103Standard Materials 39- 44∅ ∅ EGC 70-44

Die Cast Aluminium3" 82C

44- 49∅ ∅ EGC 82-493" 142 225 117

49- 54∅ ∅ EGC 82-54

Standard Finish 4" 104C 54- 69∅ ∅ EGC 104-69 4" 182 264 149

Stove enamelled grayish blue

◎ EPG

Hub Size Cat NoDimension Cable Diameter

A B C 1 2 3

1/2" 16C EPG A16 117 22 49 09- 12∅ ∅ 13- 19∅ ∅ 19- 24∅ ∅

3/4" 22C EPG A22 121 22 56 11- 16∅ ∅ 15- 23∅ ∅ 21- 28∅ ∅

1" 28C EPG A28 128 27 64 16- 21∅ ∅ 22- 28∅ ∅ 27- 33∅ ∅

1-1/4" 36C EPG A36 130 27 79 20- 28∅ ∅ 26- 37∅ ∅ 32- 42∅ ∅

1-1/2" 42C EPG A42 168 27 89 28- 33∅ ∅ 35- 43∅ ∅ 41- 48∅ ∅

Standard Materials 2" 54C EPG A54 170 27 109 33- 44∅ ∅ 43- 55∅ ∅ 48- 60∅ ∅

2-1/2" 70C EPG A70 184 38 129 44- 57∅ ∅ 54- 70∅ ∅ 59- 75∅ ∅Steel

Option : Stainless steel

Brass 3" 82C EPG A82 196 38 149 57- 69∅ ∅ 68- 81∅ ∅ 73- 86∅ ∅

Standard Finish 4" 104C EPG A104 199 38 169 69- 80∅ ∅ 78- 93∅ ∅ 78- 98∅ ∅

Stove enamelled grayish blue

◎ EUG

<EUG>

Hub Size Cable Size Cat No. A B C D E

1/2" 16C 07- 09∅ ∅ EUG 16-9

13 1/2" 76 22 4109- 11∅ ∅ EUG 16-11

3/4" 22C10- 13∅ ∅ EUG 22-13

18 3/4" 77 22 4913- 15∅ ∅ EUG 22-15

1" 28C14- 18∅ ∅ EUG 28-18

23 1" 83 27 5418- 20∅ ∅ EUG 28-20

1-1/4" 36C18- 23∅ ∅ EUG 36-23

28 1-1/4" 84 27 6423- 26∅ ∅ EUG 36-26

1-1/2" 42C23- 28∅ ∅ EUG 42-28

34 1-1/2" 103 27 7528- 31∅ ∅ EUG 42-31

2" 54C27- 34∅ ∅ EUG 54-34

42 2" 105 27 84Standard Materials34- 38∅ ∅ EUG 54-38Steel

Option : Stainless steel

Brass2-1/2" 70C

33- 41∅ ∅ EUG 70-4155 2-1/2" 118 38 100.5

41- 49∅ ∅ EUG 70-49

3" 82C41- 52∅ ∅ EUG 82-52

64 3" 121 38 11852- 60∅ ∅ EUG 82-60Standard Finish

4" 104C55- 65∅ ∅ EUG 104-65

85 4" 129 38 139Stove enamelled grayish blue 65- 75∅ ∅ EUG 104-75

Page 244: Nb cat

SECTION - 6F

Accessories

Page 245: Nb cat

SECTION 6F

Accessories INDEXModel Product Description

Certification for

Explosion-proofPage

EXRA Reducer

Ex d IIC 6F - 1

EXRB Reducer

EXRC Reducer

EXSC Socket

SP Steel Plug

AP Aluminium Plug

SN Nipple

SL Lock Nut

6F - 2

SB Bushing

SIB Insulated Bushing

SGB Grounding Bushing

SDC Clamp

SDS Saddle

SCB Clamp Back

SUB U-Bolt

SHC Pipe Hanger

SHG Pipe Hanger

SHC Pipe Clamp

LCCI Cable Tray Conduit Clamp

LCCO Cable Tray Conduit Clamp

Page 246: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

Conduit Fitting

Accessories

Type of Explosion-proof Flameproof (Ex d IIC)

Standard Materials Standard Finish

Carbon Steel

Aluminium Alloy (AP Series)

Zinc Electroplate

Natural (AP Series)

If you want another color, contact us please.

Types Reducer Types Socket Plug Nipple

Design Design

Conduit Size Large : Male

Small : Female

Large : Male

Small : Female

Large : Female

Small : Male

Conduit

SizeLarge Small

3/4” 22 1/2” 16 EXRA 2216 EXRB 2216 EXRC 2216

16 1/2” EXSC 16 SP 16 AP 16 SN 161” 28

1/2” 16 EXRA 2816 EXRB 2816 EXRC 2816

3/4” 22 EXRA 2822 EXRB 2822 EXRC 2822

1-1/4” 36

1/2” 16 EXRA 3616 EXRB 3616 EXRC 3616

22 3/4” EXSC 22 SP 22 AP 22 SN 223/4” 22 EXRA 3622 EXRB 3622 EXRC 3622

1” 28 EXRA 3628 EXRB 3628 EXRC 3628

1-1/2” 42

1/2” 16 EXRA 4216 EXRB 4216 EXRC 4216

28 1” EXSC 28 SP 28 AP 28 SN 283/4” 22 EXRA 4222 EXRB 4222 EXRC 4222

1” 28 EXRA 4228 EXRB 4228 EXRC 4228

1-1/4” 36 EXRA 4236 EXRB 4236 EXRC 4236

36 1-1/2” EXSC 36 SP 36 AP 36 SN 36

2” 54

1/2” 16 EXRA 5416 EXRB 5416 EXRC 5416

3/4” 22 EXRA 5422 EXRB 5422 EXRC 5422

1” 28 EXRA 5428 EXRB 5428 EXRC 5428

42 1-1/2” EXSC 42 SP 42 AP 42 SN 421-1/4” 36 EXRA 5436 EXRB 5436 EXRC 5436

1-1/2” 42 EXRA 5442 EXRB 5442 EXRC 5442

2-1/2” 70

3/4” 22 EXRA 7022 EXRB 7022 EXRC 7022

54 2” EXSC 54 SP 54 AP 54 SN 541” 28 EXRA 7028 EXRB 7028 EXRC 7028

1-1/4” 36 EXRA 7036 EXRB 7036 EXRC 7036

1-1/2” 42 EXRA 7042 EXRB 7042 EXRC 7042

70

2-1/2”EXSC 70 SP 70 AP 70 SN 702” 54 EXRA 7054 EXRB 7054 EXRC 7054

3” 82

1” 28 EXRA 8228 EXRB 8228 EXRC 8228

1-1/4” 36 EXRA 8236 EXRB 8236 EXRC 8236

82 3” EXSC 82 SP 82 AP 82 SN 821-1/2” 42 EXRA 8242 EXRB 8242 EXRC 8242

2” 54 EXRA 8254 EXRB 8254 EXRC 8254

2-1/2” 70 EXRA 8270 EXRB 8270 EXRC 8270

92

3-1/2”EXSC 92 SP 92 AP 92 SN 92

3-1/2” 92

1-1/4” 36 EXRA 9236 EXRB 9236 EXRC 9236

1-1/2” 42 EXRA 9242 EXRB 9242 EXRC 9242

2” 54 EXRA 9254 EXRB 9254 EXRC 9254

104 4” EXSC 104 SP 104 AP 104 SN 1042-1/2” 70 EXRA 9270 EXRB 9270 EXRC 9270

3” 82 EXRA 9282 EXRB 9282 EXRC 9282

4” 104

1-1/2” 42 EXRA 10442 EXRB 10442 EXRC 10442

2” 54 EXRA 10454 EXRB 10454 EXRC 10454

2-1/2” 70 EXRA 10470 EXRB 10470 EXRC 10470

3” 82 EXRA 10482 EXRB 10482 EXRC 10482

3-1/2” 92 EXRA 10492 EXRB 10492 EXRC 10492

Page 247: Nb cat

Conduit Fitting

Copyright by NAMBUK Electric Co., LTD. 2004

Types Lock Nut Bushing Insulated Bushing Grounding Bushing

Design

Standard Materials Steel or Zinc Alloy Zinc Alloy

Standard Finish Zinc Electroplate

Conduit Size Catalog Number

16 1/2” SL 16 SB 16 SIB 16 SGB 16

22 3/4” SL 22 SB 22 SIB 22 SGB 22

28 1” SL 28 SB 28 SIB 28 SGB 28

36 1-1/2” SL 36 SB 36 SIB 36 SGB 36

42 1-1/4” SL 42 SB 42 SIB 42 SGB 42

54 2” SL 54 SB 54 SIB 54 SGB 54

70 2-1/2” SL 70 SB 70 SIB 70 SGB 70

82 3” SL 82 SB 82 SIB 82 SGB 82

92 3-1/2” SL 92 SB 92 SIB 92 SGB 92

104 4” SL 104 SB 104 SIB 104 SGB 104

Types Clamp Saddle Clamp Back U-Bolt with Nut

Design

Standard Materials Cast Iron or Steel Steel

Standard FinishCast Iron : Hot Dip Galvanized

Steel : Zinc ElectroplateHot Dip Galvanized Zinc Electroplated

Conduit Size Catalog Number

16 1/2” SDC 16 SDS 16 SCB 16 SUB 16

22 3/4” SDC 22 SDS 22 SCB 22 SUB 22

28 1” SDC 28 SDS 28 SCB 28 SUB 28

36 1-1/2” SDC 36 SDS 36 SCB 36 SUB 36

42 1-1/4” SDC 42 SDS 42 SCB 42 SUB 42

54 2” SDC 54 SDS 54 SCB 54 SUB 54

70 2-1/2” SDC 70 SDS 70 SCB 70 SUB 70

82 3” SDC 82 SDS 82 SCB 82 SUB 82

92 3-1/2” SDC 92 SDS 92 SCB 92 SUB 92

104 4” SDC 104 SDS 104 SCB 104 SUB 104

Types Pipe Hanger Pipe Clamp Cable Tray Conduit Clamp

Design

Standard Materials SteelBody : Cast Iron

Hook : Steel

Standard Finish Zinc Electroplate Hot Dip Galvanized

Conduit Size Catalog Number

16 1/2” SHC 16 SHG 16 SPC 16 LCCI 16 LCCO 16

22 3/4” SHC 22 SHG 22 SPC 22 LCCI 22 LCCO 22

28 1” SHC 28 SHG 28 SPC 28 LCCI 28 LCCO 28

36 1-1/2” SHC 36 SHG 36 SPC 36 LCCI 36 LCCO 36

42 1-1/4” SHC 42 SHG 42 SPC 42 LCCI 42 LCCO 42

54 2” SHC 54 SHG 54 SPC 54 LCCI 54 LCCO 54

70 2-1/2” SHC 70 SHG 70 SPC 70 LCCI 70 LCCO 70

82 3” SHC 82 SHG 82 SPC 82 LCCI 82 LCCO 82

92 3-1/2” SHC 92 SHG 92 SPC 92 LCCI 92 LCCO 92

104 4” SHC 104 SHG 104 SPC 104 LCCI 104 LCCO 104

Page 248: Nb cat

Fire Protection

Copyright by NAMBUK Electric Co., LTD. 2004

Detector

EXFD Series

< EXFD >

Type of Explosion-proof Flameproof (Ex d IIB T4)

Application

EXFD Series detectors are used ;

in oil refinery, power electric plant and chemical

plant where hazardous locations.

Features

The enclosures are composed of the main body,

cover inner barrier and terminal box joined together

with threaded and spigot joints.

The cover can be unscrewed by releasing one

locking bolt, and the replacement of the fuse links is

easily done.

Two type - Bimetal & Electronic type.

Dimension

Standard Materials

Body : Cast aluminium alloy

Cover : Cast aluminium alloy

Standard Finish

MUNSELL No. 7.5BG 6/1.5

MUNSELL No. 7.5R 3/12 (Red)

If you want another color, contact us please.

CertificationCompliance Certified by KOSHA (Korea Occupational Safety &

Health Agency), KOFEIC (Korea Fire Equipment

Inspection Corporation), KGS (Korea Gas Safety

Corporation), and the others.

IEC 60079-0, 1

Fire Protection Law of Korea

Technical Data

Catalog No. Rating Operation TypeOperating Temp.

( )℃Weight (g)

Classification of

Explosion-proof

EXFD-60 DC 24V / 100mA Bimetal 60 Ex d IIB T4

EXFD-90 DC 24V / 1A Bimetal 90 Ex d IIB T4 H2

EXED-60 DC 24V / 100mA Electronic 60 Ex d IIB T4

EXED-90 DC 24V / 100mA Electronic 90 Ex d IIB T4

If you need more information, contact us please. ⇨