SECTION - 1L
Incandescent Lighting Fixture
SECTION 1L
Incandescent Lighting Fixtures INDEX
Model
Lamp Type / Watt. Certification for Explosion-proof
PAGEIncandescent lampIEC UL
20 60 100 150 200 300
VDY ● ● 1L - 1
SYL ● ● Ex e II T1 1L - 4
EML ● ● Ex d IIB T3 1L - 7
EUL ● ● Ex d IIB T3 1L - 9
EULS ●Ex d IIB T4
Ex DP II 12 IP551L - 12
EFL ● ● ●Ex d IIC T3
Ex d IIC T5
Class I Division 1,2
Group C,D1L - 15
POLE TYPE Flameproof, Increased Safety, Vaportight Type Pole 1L -19
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent Lighting Fixtures
VDY Series
Weathertight
NEMA 3, 3R, 5
Application Features Standard Materials
VDY Series lighting fixtures are used ;
in manufacturing plants,
refineries, chemical,
petrochemical and other industrial
process facilities, wastewater and
sewage treatment plants,
offshore, dockside and other
harbor installations as well as
other heavy industrial
applications.
wherever the damaging effects of
wind, snow, sleet, or hot sun are
found.
in marine applications where
water spray and corrosive
atmospheres are considerations.
in paint spray booth suitability
provides efficient, economical
HID lighting for paint spray
areas.
in industrial areas, both indoors
and outdoors where long life and
low maintenance costs are
desired.
in Industrial locations requiring
elevated ambient capability.
The lighting fixture has simple
construction.
The screw neck globe and the
guard are screwed on to the
body applying the reflector in its
position by the guard.
Synthetic rubber gasket is used
between the body and globe, so
that the lamp housing is sealed
against vapors and dusts.
Relamping is easily done by
opening lower half of the guard
and unscrewing the globe.
H.I.D lighting fixture has external
type ballast.
Body : Die casting aluminium
Globe : Heat resistant hard glass
Reflector : White coating
aluminium
Mounting Box : Cast aluminium
alloy
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
< VDY >
Certification
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Compliance Technical DataIP55 Electrical Ratings
Rated Voltage AC110V/ 220V/ 240V/ DC110V
Rated Wattage 100W/ 200W
Rated Frequency 50Hz/ 60Hz
Entry Sizes 1/2", 3/4", 1"
Weight
Mounting Type Catalog No. Weight
Ceiling (Small) VDY 2105 2.2 kg
Ceiling (Large) VDY 2205 4.5 kg
If you need more information, contact us please.⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt Hub Size Pendant Ceiling 90° Bracket 40° Bracket
Incandescent
Lamp
1001/2" VDY 1105 VDY 2105 VDY 3105 VDY 4105
3/4" VDY 1103 VDY 2103 VDY 3103 VDY 4103
2001/2" VDY 1205 VDY 2205 VDY 3205 VDY 4205
3/4" VDY 1203 VDY 2203 VDY 3203 VDY 4203
Ordering Information
V D Y 1 1 0 5 ① ② ③ ④
VDY Lighting Fixture① : Mounting Type② : Lamp Wattage (W)③ : Entry Size④
1 - Pendant 10 - 100 1 - 1"
2 - Ceiling 20 - 200 3 - 3/4"
3 - 90° Bracket 5 - 1/2"
4 - 40° Bracket
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<VDY 2105> 0 145 50 130
5 135 55 115Lamp : IL100 (1250 lm)+
With Globe and Guard+
Reflector : +
White Coating Aluminum
Reflector
10 150 60 95.0
15 180 65 80.0
20 150 70 90.0
25 140 75 25.0
30 160 80 15.0
35 145 85 5.0
40 130 90 0.0
45 135
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall
Reflectance(ρw)50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio
RCR20% Effective Floor Cavity Reflectance
0 .64 .64 .64 .63 .63 .63 .60 .60 .60 .57 .57 .57 .55 .55 .55 .54
1 .57 .55 .54 .56 .54 .53 .54 .52 .51 .52 .51 .50 .50 .49 .48 .47
2 .52 .49 .46 .51 .48 .45 .49 .46 .44 .47 .45 .43 .45 .44 .42 .41
3 .46 .43 .40 .46 .42 .39 .44 .41 .39 .43 .40 .38 .41 .39 .38 .36
4 .42 .38 .35 .41 .38 .35 .40 .37 .34 .39 .36 .34 .38 .35 .33 .32
5 .38 .34 .31 .38 .34 .31 .37 .33 .30 .36 .33 .30 .35 .32 .30 .29
6 .35 .31 .28 .34 .30 .28 .34 .30 .27 .33 .30 .27 .32 .29 .27 .26
7 .32 .28 .25 .32 .28 .25 .31 .27 .25 .30 .27 .25 .29 .27 .24 .23
8 .30 .26 .23 .29 .25 .23 .29 .25 .23 .28 .25 .22 .27 .24 .22 .21
9 .28 .24 .21 .27 .23 .21 .27 .23 .21 .26 .23 .21 .26 .23 .21 .20
10 .26 .22 .19 .25 .22 .19 .25 .22 .19 .24 .21 .19 .24 .21 .19 .18
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< VDY Pendant Type > < VDY 90° Bracket Type >
< VDY Ceiling Type > < VDY 40° Bracket Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent Lighting Fixtures
SYL Series
Wet Locations
NEMA 3, 3R, 4, 7
Type of Explosion-proof
< SYL >
Increase Safety (Ex e II T1)
Application
SYL Series lighting fixtures are used ;
in heavy process industries having environments
where flammable or explosive vapors or gases, or
where combustible dusts are present.
in hazardous areas, both indoors and outdoors where
long life and low maintenance costs are desired.
in petroleum refineries, chemical, petrochemical and
other heavy process industry facilities.
where ignitable concentrations of flammable gases,
vapors or liquids can exist all of the time or some of
the time under normal operation conditions.
Features Certification Standard Materials
The globe frame is cast in one
piece with guard.
The globe is sealed into the
globe frame firmly with
synthetic rubber gaskets, and
the globe assembly is fitted to
the body by three socket head
captive screws.
All joint of lamp housing,
including the joint between the
top body and the terminal
plate, are sealed up with high
quality gaskets so as to restrict
breathing.
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas
Safety Corporation), and the
others.
Enclosure : Aluminium sheet
Globe : Heat resistant hard glass
Globe Frame : Die casting aluminium
Mounting Box : Cast aluminium alloy
External Hardware :
Stainless steel
Compliance Standard Finish
NEMA 3 ,3R, 4, 7
IEC 60079-0, 1
IP55
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us
please.
Technical DataWeightElectrical Rating
Rated Voltage AC110V/ 220V/ 240V/ DC110V Mounting Type Catalog No. Weight
Rated Wattage 100W/ 200WCeiling SYL 2105 3.9 Kg
Entry Size 1/2", 3/4", 1"
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<SYL 2205> 0 137.0 50 132.7
5 143.4 55 149.8Lamp : IL200 (2920 lm)+
With Globe and Guard+ 10 149.8 60 102.7
15 128.4 65 98.5
20 134.9 70 34.2
25 137.0 75 15.0
30 107.0 80 6.4
35 107.0 85 4.3
40 102.7 90 2.2
45 111.3
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall
Reflectance(ρw)50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio
RCR20% Effective Floor Cavity Reflectance
0 .62 .62 .62 .60 .60 .60 .58 .58 .58 .55 .55 .55 .53 .53 .53 .52
1 .55 .53 .51 .54 .52 .51 .52 .50 .49 .50 .49 .47 .48 .47 .46 .45
2 .49 .46 .44 .48 .45 .43 .46 .44 .42 .45 .43 .41 .43 .42 .40 .39
3 .44 .40 .37 .43 .40 .37 .42 .39 .36 .40 .38 .36 .39 .37 .35 .34
4 .40 .35 .32 .39 .35 .32 .38 .34 .32 .36 .34 .31 .35 .33 .31 .30
5 .36 .31 .28 .35 .31 .28 .34 .31 .28 .33 .30 .28 .32 .29 .27 .26
6 .32 .28 .25 .32 .28 .25 .31 .27 .25 .30 .27 .24 .29 .26 .24 .23
7 .29 .25 .22 .29 .25 .22 .28 .25 .22 .28 .24 .22 .27 .24 .22 .21
8 .27 .23 .20 .27 .23 .20 .26 .22 .20 .25 .22 .20 .25 .22 .20 .19
9 .25 .21 .18 .25 .21 .18 .24 .21 .18 .23 .20 .18 .23 .20 .18 .17
10 .23 .19 .17 .23 .19 .17 .22 .19 .17 .22 .19 .16 .21 .18 .16 .16
Ordering Number
Lamp WattHub
SizePendant Ceiling 90° Bracket 40° Bracket Certification
Incandescent
Lamp
1001/2" SYL 1105 SYL 2105 SYL 3105 SYL 4105
Ex e II T13/4" SYL 1103 SYL 2103 SYL 3103 SYL 4103
2001/2" SYL 1205 SYL 2205 SYL 3205 SYL 4205
3/4" SYL 1203 SYL 2203 SYL 3203 SYL 4203
Ordering Information
S Y L 1 1 0 5 ① ② ③ ④
SYL Lighting Fixture① ② Mounting Type Lamp Wattage (W)③ Entry Size④
1 - Pendant 10 - 100 1 - 1"
2 - Ceiling 20 - 200 3 - 3/4"
3 - 90° Bracket 5 - 1/2"
4 - 40° Bracket
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< SYL Ceiling Type > < SYL Pendant Type >
< SYL 90° Bracket Type > < SYL 40° Bracket Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent Lighting Fixtures
EML Series
Wet Locations
NEMA 3, 3R, 7
<EML 8024>
Type of Explosion-proof Flameproof (Ex d IIB T3)
Application
EML Series incandescent lighting fixtures are used ;
for flush or surface mounting on ceiling, wall or
pedant in conduit systems.
in hazardous areas, both indoors and outdoors where
enclosed and gasketed fixtures are required.
in tunnels, building entrances and similar locations,
where moisture, dirt, chemicals, vibration or rough
usage are a problem.
where ignitable concentrations of flammable gases,
vapors, liquids or dusts can exist some of the time
under normal operating conditions.
Features Designed to exclude dirt, moisture and corrosive
vapors from the interior of the fixtures and the
conduit system.
The globe-guard assembly in installed and removed
as a unit making it necessary to handle only one
piece in relamping.
All fixtures are rugged and corrosion-resistant.
Standard Materials
Enclosure : Cast aluminium alloy
Globe : Heat resistant hard glass
Globe Ring : Cast aluminium alloy
Guard : Stainless steel wire
Compliance IEC 60079-0, 1
NEMA 3, 3R, 7
IP 55
CertificationCertified by KOSHA (Korea Occupational Safety &
Health Agency), KGS (Korea Gas Safety Corporation),
and the others.
Weight
Mounting Type Catalog No. Weight
Ceiling EML 8024 4.7 Kg
Standard Finish Technical Data
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Electrical Rating
Rated VoltageAC110V/ 220V/ 240V
DC110V
Rated Wattage 100W/ 150W/ 200W/ 300WOptionsEntry Size 1/2", 3/4", 1"
Guard : Stainless steel
Reflector : Aluminium Dome Reflector
Aluminium 30° Angle Reflector
Pole type pendant
* Atmosphere Temp : -20 ~ 55℃ ℃
Ordering Number
Lamp Watt Pendant Ceiling Bracket Certification
Incandescent Lamp
100 EML 8011 EML 8021 EML 8031
Ex d IIB T3150 EML 8014 EML 8024 EML 8034
200 EML 8012 EML 8022 EML 8032
300 EML 8013 EML 8023 EML 8033
* For Pole type, see pole section (1L-19)
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<EML 8021> 0 75 50 130
5 76 55 132Lamp : IL100 (1250 lm)+
With Globe and+
without Guard
10 80 60 139
15 88 65 143
20 92 70 147
25 101 75 151
30 111 80 150
35 118 85 150
40 126 90 150
45 129
Coefficients of Utilization - Zonal Cavity%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall
Reflectance(ρw)50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio
RCR20% Effective Floor Cavity Reflectance
0 .88 .88 .88 .86 .86 .86 .82 .82 .82 .78 .78 .78 .75 .75 .75 .74
1 .74 .70 .66 .72 .68 .65 .69 .66 .63 .66 .63 .61 .63 .61 .59 .57
2 .62 .55 .50 .60 .54 .49 .57 .52 .48 .55 .51 .47 .52 .49 .46 .44
3 .52 .45 .39 .51 .44 .39 .49 .43 .38 .47 .42 .37 .45 .40 .37 .35
4 .45 .38 .32 .44 .37 .32 .42 .36 .31 .40 .35 .31 .39 .34 .30 .28
5 .40 .32 .27 .39 .32 .26 .37 .31 .26 .36 .30 .26 .34 .29 .25 .24
6 .35 .28 .23 .35 .28 .23 .33 .27 .22 .32 .26 .22 .31 .26 .22 .20
7 .32 .25 .20 .31 .24 .20 .30 .24 .19 .29 .23 .19 .28 .23 .19 .17
8 .29 .22 .17 .28 .22 .17 .27 .21 .17 .26 .21 .17 .26 .21 .17 .15
9 .27 .20 .15 .26 .20 .15 .25 .19 .15 .24 .19 .15 .24 .19 .15 .14
10 .30 .24 .20 .29 .24 .20 .29 .24 .20 .28 .23 .20 .27 .23 .20 .19
Dimension
<EML Ceiling Type> < EML Pendant Type > < EML Bracket Type>
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent Lighting Fixtures
EUL Series
Wet Locations
Factory Sealed
NEMA 3, 3R, 7
Type of Explosion-proof
Flameproof (Ex d IIB T3)
<EUL 3021>
Features
The body is cast in one piece,
and the upper part of which
forms a terminal chamber.
Globe assembly is securely
hinged to the body.
Mounting box has four-way
conduit entries and a large
access cover for wiring.
The globe holder is fixed to the
base of the body with special
flameproof and weatherproof
flanged joint.
The guard is so constructed that
can be hinged down for
cleaning the globe.
Application
EUL Series lighting fixtures are used ;
in tunnels, building entrances and
similar locations where moisture,
dirt, chemicals or rough usage are
a problem.
in heavy process industries having
environments where flammable or
explosive vapors or gases, or where
combustible dusts are present.
in areas where combustible dusts
and flammable vapors are present
simultaneously.
in hazardous areas, both indoors
and
outdoors where long life and low
maintenance costs are desired.
where high light output is needed
but space is limited.
where ignitable concentrations of
flammable gases, vapors, liquids or
dusts can exist some of the time
under normal operating conditions.
Compliance
IEC 60079-0, 1
NEMA 3, 3R, 7
IP 55
Certification
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Standard Materials Standard Finish
Enclosure : Die casting aluminium
Globe : Heat resistant hard glass
Inner Reflector : High purity aluminium
External Hardware : Stainless steel
Mounting Box : Cast aluminium alloy
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated Voltage AC110V/ 220V/ 240V/ DC110V Ceiling EUL 3022 3.7 ㎏
Rated Wattage 100W/ 200W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt Pendant Ceiling 90° Bracket 40° Bracket Certification
Incandescent Lamp100 EUL 3011 EUL 3021 EUL 3031 EUL 3041
Ex d IIB T3200 EUL 3012 EUL 3022 EUL 3032 EUL 3042
* For Pole type, see pole section (1L-19)
Ordering Information Temperature Performance Data
E U L 3 0 2 1 Lamp Ambient Flameproof Dust-Ignition
① ② ③ Type Watt. Temp ( )℃ "d" "DP"
EUL Lighting Fixture① Mounting Type②
Incandescent
10040 T4 11
1 - Pendant 55 T3 -
Wattage (W)③ 2 - Ceiling200
40 T4 11
1 - 100 3 - 90° Bracket 55 T3 -
2 - 200 4 - 40° Bracket
Dimension
<Ceiling Type> <Pendant Type> <90° Bracket Type > <40° Bracket Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle /1000㏅ ㏐ Angle /1000㏅ ㏐
<EUL 3021> 0 167 50 133
5 180 55 132Lamp : IL100 (1250lm)+
With Guard+ 10 138 60 158
15 140 65 119
20 136 70 120
25 146 75 107
30 175 80 91.8
35 171 85 27.7
40 162 90 10.1
45 153
Coefficients of Utilization - Zonal Cavity%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .87 .87 .87 .85 .85 .85 .81 .81 .81 .78 .78 .78 .75 .75 .75 .73
1 .76 .73 .70 .74 .71 .69 .71 .69 .67 .68 .66 .65 .66 .64 .63 .61
2 .67 .62 .57 .65 .61 .57 .63 .59 .55 .60 .57 .54 .58 .55 .53 .51
3 .59 .53 .48 .57 .52 .47 .55 .50 .47 .53 .49 .46 .51 .48 .45 .43
4 .52 .46 .41 .51 .45 .40 .49 .44 .40 .47 .43 .39 .46 .42 .39 .37
5 .46 .40 .35 .46 .39 .35 .44 .39 .35 .43 .38 .34 .41 .37 .34 .32
6 .42 .35 .31 .41 .35 .31 .40 .34 .30 .39 .34 .30 .38 .33 .30 .28
7 .38 .32 .27 .38 .32 .27 .36 .31 .27 .35 .30 .27 .34 .30 .27 .25
8 .35 .29 .25 .34 .29 .24 .33 .28 .24 .33 .28 .24 .32 .27 .24 .23
9 .32 .26 .22 .32 .26 .22 .31 .26 .22 .30 .25 .22 .29 .25 .22 .21
10 .30 .24 .20 .29 .24 .20 .29 .24 .20 .28 .23 .20 .27 .23 .20 .19
Angle /1000㏅ ㏐ Angle /1000㏅ ㏐
<EUL 3022> 0 172 50 83.8
5 157 55 85.3Lamp : IL200 (2920lm)+
With Guard+ 10 166 60 70.7
15 152 65 82.1
20 138 70 92.5
25 143 75 84.6
30 127 80 78.3
35 103 85 79.2
40 92.5 90 95.4
45 87.9
Coefficients of Utilization - Zonal Cavity%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .70 .70 .70 .69 .69 .69 .66 .66 .66 .63 .63 .63 .60 .60 .60 .59
1 .60 .57 .54 .59 .56 .54 .56 .54 .52 .54 .52 .50 .52 .50 .49 .47
2 .52 .47 .43 .50 .46 .43 .48 .45 .42 .46 .43 .41 .44 .42 .40 .38
3 .45 .40 .36 .44 .39 .35 .42 .38 .35 .41 .37 .34 .39 .36 .33 .32
4 .40 .34 .30 .39 .34 .30 .38 .33 .30 .36 .32 .29 .35 .32 .29 .27
5 .36 .30 .26 .35 .30 .26 .34 .29 .26 .33 .29 .26 .32 .28 .25 .24
6 .33 .27 .23 .32 .27 .23 .31 .26 .23 .30 .26 .23 .29 .25 .23 .21
7 .30 .25 .21 .29 .24 .21 .29 .24 .21 .28 .24 .21 .27 .23 .20 .19
8 .28 .23 .19 .27 .22 .19 .26 .22 .19 .26 .22 .19 .25 .21 .19 .18
9 .26 .21 .18 .25 .21 .17 .25 .20 .17 .24 .20 .17 .23 .20 .17 .16
10 .24 .19 .16 .24 .19 .16 .23 .19 .16 .23 .19 .16 .22 .19 .16 .15
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent / Compact Fluorescent
Lighting Fixtures
EULS Series
Wet Locations
Factory Sealed
NEMA 3, 3R, 7
Type of Explosion-proof
Flameproof (Ex d IIB T4)
Dust Ignition-proof (Ex DP II 12 IP55)
Application Features
EULS Series lighting fixtures are used ;
in tunnels, building entrances
and similar locations where
moisture, dirt, chemicals or
rough usage are a problem.
in heavy process industries
having environments where
flammable or explosive vapors or
gases, or where combustible
dusts are present.
in areas where combustible
dusts and flammable vapors are
present simultaneously.
in hazardous areas, both indoors
and outdoors where long life
and low maintenance costs are
desired.
where high light output is
needed but space is limited.
where ignitable concentrations of
flammable gases, vapors, liquids
or dusts can exist some of the
time under normal operating
conditions.
< EULS >
Globe assembly is securely
hinged to the body.
Mounting box has four-way
conduit entries and a large
access opening cover for wiring.
Standard Materials
Enclosure :
Die casting aluminium
Globe :
Heat resistant hard glass
Inner Reflector :
High purity aluminium
External Hardware :
Stainless steel
Mounting Box : Cast aluminium
alloy
Compliance & Certification Standard Finish
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
IEC 60079- 0.1
NENA 3.3R.7
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated Voltage AC110V/ 220V/ 240V/ DC110V Ceiling EULS 3021 2.8 ㎏
Rated Wattage IL 100W/ CFL 20W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt Pendant Ceiling90°
Bracket
40°
BracketCertification
Incandescent Lamp 100 EULS 3021 Ex d IIB T4
Compact Self Ballast Fluorescent Lamp 20 EULS 3022 Ex DP II 12
* Pendant , 90° and 40° Bracket types are order-made items.
Ordering Information Temperature Performance Data
E U LS 3 0 2 1 Lamp Ambient Flameproof Dust-Ignition
① ② ③ ④ Type Watt. Temp ( )℃ "d" "DP"
, EULS Lighting Fixture① ② Watt④ Incandescent 100
40 T4 -
0 - 20 55 - -
Mounting Type③ 1 - 100 Compact
Fluorescent20
40 T5 12
1 - Pendant 55 - -
2 - Ceiling
3 - 90° Bracket
4 - 40° Bracket
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<EULS 3021> 0 124 50 109
5 108 55 139Lamp : IL 100 (1250 )+ ㏐
With Globe and Guard+ 10 96.5 60 131
15 128 65 123
20 126 70 128
25 124 75 107
30 118 80 66.8
35 111 85 19.6
40 128 90 10.8
45 124
Coefficients of Utilization - Zonal Cavity%Effective Ceiling
Cavity
Reflectance( cc)ρ
80 70 50 30 10 0
%Wall
Reflectance(ρw)50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio
RCR20% Effective Floor Cavity Reflectance
0 .77 .77 .77 .76 .76 .76 .72 .72 .72 .69 .69 .69 .66 .66 .66 .65
1 .68 .65 .63 .66 .64 .62 .64 .61 .60 .61 .59 .58 .59 .57 .56 .55
2 .59 .55 .51 .58 .54 .50 .55 .52 .49 .53 .50 .48 .51 .49 .47 .45
3 .52 .46 .42 .51 .46 .42 .49 .44 .41 .47 .43 .40 .45 .42 .39 .38
4 .45 .40 .35 .45 .39 .35 .43 .38 .34 .41 .37 .34 .40 .36 .34 .32
5 .40 .35 .30 .40 .34 .30 .38 .33 .30 .37 .33 .29 .36 .32 .29 .28
6 .36 .30 .26 .36 .30 .26 .35 .30 .26 .33 .29 .26 .32 .28 .25 .24
7 .33 .27 .23 .32 .27 .23 .31 .26 .23 .30 .26 .23 .29 .25 .22 .21
8 .30 .24 .21 .30 .24 .20 .29 .24 .20 .28 .23 .20 .27 .23 .20 .19
9 .28 .22 .19 .27 .22 .18 .26 .22 .18 .26 .21 .18 .25 .21 .18 .17
10 .26 .20 .17 .25 .20 .17 .25 .20 .17 .24 .20 .17 .23 .19 .17 .15
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Angle cd/1000 lm Angle cd/1000 lm
<EULS 3022> 0 47.8 50 94.2
5 48.5 55 97.7Lamp : CFL20 (1200 )+ ㏐
With Globe and Guard+ 10 49.3 60 99.9
15 51.3 65 101
20 56.3 70 102
25 61.8 75 101
30 70.3 80 98.4
35 78.0 85 94.2
40 83.7 90 90.7
45 89.4
Coefficients of Utilization - Zonal Cavity%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .67 .67 .67 .66 .66 .66 .63 .63 .63 .60 .60 .60 .57 .57 .57 .56
1 .56 .54 .51 .55 .52 .50 .53 .50 .48 .50 .49 .47 .48 .47 .45 .44
2 .47 .43 .39 .46 .42 .38 .44 .40 .37 .42 .39 .36 .40 .38 .35 .34
3 .40 .35 .30 .39 .34 .30 .37 .33 .29 .36 .32 .29 .34 .31 .28 .27
4 .35 .29 .24 .34 .29 .24 .32 .28 .24 .31 .27 .24 .30 .26 .23 .22
5 .30 .25 .20 .30 .24 .20 .29 .24 .20 .27 .23 .20 .26 .22 .19 .18
6 .27 .21 .17 .27 .21 .17 .25 .21 .17 .24 .20 .17 .23 .20 .17 .15
7 .24 .19 .15 .24 .19 .15 .23 .18 .15 .22 .18 .15 .21 .17 .14 .13
8 .22 .17 .13 .22 .17 .13 .21 .16 .13 .20 .16 .13 .19 .16 .13 .12
9 .20 .15 .12 .20 .15 .12 .19 .15 .11 .18 .14 .11 .18 14 .11 .10
10 .18 .14 .10 .18 .13 .10 .18 .13 .10 .17 .13 .10 .16 .13 .10 .09
Dimension
< Ceiling Type>
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent Lighting Fixtures
EFL Series
Wet Locations
Factory Sealed
NEMA 3, 3R, 7
Type of Explosion-proof
Class I Division 1,2 Group C,D
Flameproof (Ex d IIC T3)Features
Application
<EFL 6021>
Factory sealed - no external seal
required
Easy to assemble and relamping
Light weight
Corrosion resistant
Inner reflector eliminates upward
spill light
EFL Series lighting fixtures are used ;
in locations which are hazardous
due to the presence of
flammable vapors or gases and
where dampness or corrosion are
present.
as pendant, ceiling, wall bracket
or bulkhead fixtures, indoor for
general area or room lighting and
outdoor for spot lighting.
Standard Materials
Enclosure :
Die casting aluminium
Globe : Heat resistant hard glass
Inner Reflector :
Extra pure aluminium
Guard : Die casting aluminium
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Certification Compliance
UL Listed File No. E 131747
Certified by UL (Underwriters Laboratories Inc.),
KOSHA (Korea Occupational Safety & Health
Agency), KGS (Korea Gas Safety Corporation), and
the others.
NEC - Class I Division 1,2 Group C,D,
UL 844 - Lighting Fixtures for Use in Hazardous
(Classified) Locations
IEC 60079-0, 1
NEMA 3, 3R, 7
IP 55
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated Voltage Max. 240V (120V/ 220V for UL Listed) Pendant EFL 6011 5.3 ㎏
Rated Wattage 100W/ 200W/ 300W Ceiling EFL 6021 5.2 ㎏
Rated Frequency 50Hz/ 60Hz Bulkhead EFL 6043 7.3 ㎏
Entry Size 1/2", 3/4", 1" Bracket EFL 6033 8.1 ㎏
Ordering Number
Lamp Watt Pendant Ceiling Bracket Bulkhead Certification
Incandescent
100 EFL 6011 EFL 6021 EFL 6031 EFL 6041
Class I Division 1,2 Group C,D
Ex d IIC T3200 EFL 6012 EFL 6022 EFL 6032 EFL 6042
300 EFL 6013 EFL 6023 EFL 6033 EFL 6043
If you need more information, contact us please ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Information Temperature Performance Data
E F L 6 0 1 1 Lamp Ambient Class I Flameproof
① ② ③ ④ Type Watt. Temp ( )℃ Group C,D "d"
Incandes
cent
10040 120 (T4A) T3
EFL Lighting Fixture① Mounting Type③ Watt④ 55 - -
1 - Pendant 1 - 100200
40 160(T3C) / 120(T4A)* T3
Lamp Type② 2 - Ceiling 2 - 200 55 - -
60 - Incandescent 3 - Bracket 3 - 300300
40 160 (T3C) T3
4 - Bulkhead 55 - -
* are when use 300W body
Dimension
<Ceiling Type>
<Bracket Type>
<Bulkhead Type>
<Pendant Type>
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<EFL 6013> 0 124 50 86.8
5 118 55 92.7Lamp : IL300 (4278 lm)+
With Guard+ 10 112 60 94.6
15 108 65 98.6
20 96.7 70 104
25 90.7 75 86.8
30 80.9 80 82.9
35 74.9 85 80.9
40 73.0 90 78.8
45 77.0
Coefficients of Utilization - Zonal Cavity%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .66 .66 .66 .64 .64 .64 .61 .61 .61 .59 .59 .59 .56 .56 .56 .55
1 .56 .53 .50 .54 .52 .49 .52 .50 .48 .50 .48 .46 .48 .46 .45 .44
2 .47 .43 .39 .46 .42 .38 .44 .41 .38 .42 .39 .37 .40 .38 .36 .34
3 .41 .35 .31 .40 .35 .31 .38 .34 .30 .36 .33 .30 .35 .32 .29 .28
4 .35 .30 .26 .35 .30 .26 .33 .29 .25 .32 .28 .25 .31 .27 .25 .23
5 .31 .26 .22 .31 .26 .22 .30 .25 .22 .28 .24 .21 .27 .24 .21 .20
6 .28 .23 .19 .28 .23 .19 .27 .22 .19 .26 .22 .19 .25 .21 .18 .17
7 .26 .20 .17 .25 .20 .17 .24 .20 .17 .23 .19 .16 .23 .19 .16 .15
8 .23 .18 .15 .23 .18 .15 .22 .18 .15 .22 .18 .15 .21 .17 .15 .14
9 .22 .17 .14 .21 .17 .14 .21 .16 .13 .20 .16 .13 .19 .16 .13 .12
10 .20 .15 .12 .20 .15 .12 .19 .15 .12 .19 .15 .12 .18 .15 .12 .11
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Compact Fluorescent Lighting Fixtures
EFL Series
Wet Locations
Factory Sealed
NEMA 3, 3R, 7
Type of Explosion-proof
Flameproof (Ex d IIC T5)
<EFL 7014>
Features
Factory sealed - no external seal
required
Easy to assemble and relamping
Light weight
Corrosion resistant
Inner reflector eliminates upward
spill light
Use compact fluorescent lamp 20W
instead of incandescent lamp.
Application
EFL Series lighting fixtures are used ;
in locations which are hazardous
due to the presence of flammable
vapors or gases and where
dampness or corrosion are
present.
as pendant, ceiling, wall bracket
or bulkhead fixtures, indoor for
general area or room lighting and
outdoor for spot lighting.Standard Materials
Enclosure :
Die casting aluminium
Globe : Heat resistant hard glass
Inner Reflector :
Extra pure aluminium
Guard : Die casting aluminium
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact
us please.
Certification Compliance
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS(Korea Gas Safety
Corporation), and the others.
IEC 60079-0, 1
NEMA 3, 3R, 7
IP 55
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated Voltage Max. AC240V Pendant EFL 7014 5.3 ㎏
Rated Wattage Compact Fluorescent 20W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
Ordering Number
Lamp Watt Pendant Ceiling Bracket Bulkhead Certification
Compact Fluorescent 20 EFL 7014 EFL 7024 EFL 7034 EFL 7044 Ex d IIC T5
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Information Temperature Performance Data
E F L 7 0 1 4 Lamp Ambient Flameproof
① ② ③ ④ Type Watt. Temp ( )℃ "d"
Compact
Fluorescent20
40 T5
EFL Lighting Fixture① Mounting Type③ Watt : 4 - 20④ 55 -
1 - Pendant
Lamp Type② 2 - Ceiling
70 - Compact Fluorescent 3 - Bracket
4 - Bulkhead
Dimension
<Ceiling Type>
<Bracket Type>
<Bulkhead Type>
<Pendant Type>
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
0 63.3 50 86.5<EFL 7014>
5 63.3 55 92.2Lamp : CFL20 (1200 lm)+
With Guard+ 10 64.0 60 98.4
15 65.3 65 101
20 71.8 70 104
25 78.7 75 108
30 80.2 80 104
35 78.0 85 99.9
40 76.7 90 92.9
45 80.2
▞Coefficients of Utilization - Zonal Cavity%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .69 .69 .69 .67 .67 .67 .64 .64 .64 .62 .62 .62 .59 .59 .59 .58
1 .58 .55 .52 .57 .54 .51 .54 .52 .50 .52 .50 .48 .50 .48 .47 .45
2 .48 .44 .39 .47 .43 .39 .45 .41 .38 .43 .40 .37 .41 .39 .36 .35
3 .41 .35 .31 .40 .35 .31 .38 .34 .30 .37 .33 .29 .35 .32 .29 .27
4 .36 .30 .25 .35 .29 .25 .33 .28 .25 .32 .28 .24 .30 .27 .24 .22
5 .31 .25 .21 .31 .25 .21 .29 .24 .21 .28 .24 .20 .27 .23 .20 .19
6 .28 .22 .18 .27 .22 .18 .26 .21 .18 .25 .21 .17 .24 .20 .17 .16
7 .25 .20 .16 .25 .19 .15 .24 .19 .15 .23 .18 .15 .22 .18 .15 .14
8 .23 .17 .14 .22 .17 .14 .22 .17 .14 .21 .17 .13 .20 .16 .13 .12
9 .21 .16 .12 .21 .16 .12 .20 .15 .12 .19 .15 .12 .19 .15 .12 .11
10 .19 .14 .11 .19 .14 .11 .18 .14 .11 .18 .14 .11 .17 .14 .11 .10
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent Lighting Fixtures Pole Type
Explosion proof & Vaportight
Weathertight
NEMA 3, 3R, 5
Lighting
FixturesConstruction
Lamp
Watt
Catalog Number
Hand Rail Type Pedestal Type
2.5M Height 3.5M Height 2.5M Height 3.5M Height
EFLP Series
Flameproof
Ex d IIB T3
CL I,
GR C,D
60 EFLP 60906-25H EFLP 60906-35H EFLP 60906-25P EFLP 60906-35P
100 EFLP 60910-25H EFLP 60910-25H EFLP 60910-25H EFLP 60910-35H
200 EFLP 60920-25H EFLP 60920-25H EFLP 60920-25H EFLP 60920-35H
EULP SeriesFlameproof
Ex d IIB T4
60 EULP 30906-25H EULP 30906-35H EULP 30906-25P EULP 30906-35P
100 EULP 30910-25H EULP 30910-35H EULP 30910-25H EULP 30910-35H
200 EULP 30920-25H EULP 30920-35H EULP 30920-25H EULP 30920-35H
SYLP Series
Increased
Safety
Ex e II T1
60 SYLP 70906-25H SYLP 70906-35H SYLP 70906-25P SYLP 70906-35P
100 SYLP 70910-25H SYLP 70910-35H SYLP 70910-25P SYLP 70910-35P
200 SYLP 70920-25H SYLP 70920-35H SYLP 70920-25P SYLP 70920-35P
VDYP SeriesVapor Tight
IP 54
60 VDYP 10906-25H VDYP 10906-35H VDYP 10906-25P VDYP 10906-35P
100 VDYP 10910-25H VDYP 10910-35H VDYP 10910-25P VDYP 10910-35P
200 VDYP 10920-25H VDYP 10920-35H VDYP 10920-25P VDYP 10920-35P
Features
These pole type fittings are the combinations of lighting units for Flameproof EFLP, EULP series, Increase safety
SYLP series or Vapor tight VDYP series incandescent lighting fittings and goose neck shaped poles.
These fittings are mainly used for tower illumination of chemical plant.
Additionally, fixing and wiring connection of these fittings are recommended to be done with Flameproof EOB or
Increased safety and Heavy duty SBD junction boxes in compliance with the type of protection of lighting units.
Other height not listed in the catalog are also available on request.
Conduit entry-Three(3)-28(1")max. Specify the position and size when ordering.
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< Hand Rail Type >
* Length (L) is order made.
(Standard is 2.5M, 3.5M. See front page)
< Pedestal Type >
SECTION - 2L
HID Lighting Fixture
SECTION 2L
H.I.D Lighting Fixtures INDEX
Model
Lamp Type / Watt.Certification for Explosion-proof
PAGEHigh Pressure Sodium Mercury Vapor Metal Halide
50 70 100 150 200 250 400 100 200 250 400 100 175 250 400 IEC UL
VD ● ● ● ● ● ● ● ● 2L - 1
VS ● ● ● ● ● ● ● ● ● ● ● ● ● 2L - 4
SR ● ● ● ● ● ● ● ● ● ● ● ● ● Ex nR II T3 2L - 7
VG ● ● ● ● ●
Ex nR II T4 IP66
Ex DP II 11
Class I
Division 2
Group A,B,C,D
Class II
Division 1,2
Group E,F,G
Class III
Division 1
2L - 12
VN ● ● ● ● ● ● ● 2L - 15
VZ ● ● ● ● ● ● 2L - 19
AUXILIARY H.I.D AUXILIARY LIGHTING 2L - 23
EVN ● ● ● ● ● ● ●
Ex dnR IIC T4
Ex nR II T4 IP66
Ex DP II 11 IP66
2L - 24
EU ● ● ● ● ●Ex d IIB T4
Ex DP II 122L - 30
EA ● ● ● ● ● ● ●Ex d IIC T4
Ex d IIB T42L - 33
EVS ● ● ● ● ● ● ● ● ● ● Ex de IIC T3 2L - 39
EGS ● ● ● ● ●Ex d IIC T4
Ex DP II 122L - 43
EG ● ● ● ● ● ● ● ● ● ● Ex d IIC T3Class I Division
1 Group C,D2L - 46
POLE TYPE Flameproof, Increased Safety, Vaportight Pole Type 2L - 51
SB HID Ballast 2L - 53
Accessary Globe, Guard, Reflector 2L - 55
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
VD Series
Weathertight
NEMA 3, 3R, 5
Application Features Standard Materials
VD Series lighting fixtures are used ;
in manufacturing plants, refineries,
chemical, petrochemical and
other industrial process facilities,
wastewater and sewage
treatment plants, offshore,
dockside and other harbor
installations as well as other heavy
industrial applications.
wherever the damaging effects of
wind, snow, sleet, or hot sun are
found.
in marine applications where
water spray and corrosive
atmospheres are considerations.
in paint spray booth suitability
provides efficient, economical
HID lighting for paint spray
areas.
in Industrial areas, both indoors
and outdoors where long life and
low maintenance costs are
desired.
in industrial locations requiring
elevated ambient capability.
The lighting fixture has simple
construction.
The screwneck globe and the
guard are screwed on to the
body applying the reflector in
its position by the guard.
Synthetic rubber gasket is
used between the body and
globe, so that the lamp
housing is sealed against
vapors and dusts.
Relamping is easily done by
opening lower half of the
guard and unscrewing the
globe.
H.I.D lighting fixture has
external type ballast.
Body : Die casting aluminium
Globe : Heat resistant hard glass
Reflector : White coating aluminium
Mounting Box : Cast aluminium
alloy
Certification
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Compliance
IP55
< VD >
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Technical Data Weight
Electrical Ratings Mounting Type Catalog No. Weight
Rated Voltage AC110V/ 220V/ 240V/ DC110V Ceiling (Small) VDNY 32075 8.7 Kg
Ceiling (Large) VDNY 32155 15.5 KgRated Wattage 70W/ 100W/ 150W/ 175W/ 200W
Rated Frequency 50Hz/ 60Hz
Entry Sizes 1/2", 3/4", 1"
Also you can order various voltage : ※
120V/ 208V/ 277V/ 460V
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt Hub Size Pendant Ceiling 90° Bracket 40° Bracket
High
Pressure
Sodium
701/2" VDNY 31075 VDNY 32075 VDNY 33075 VDNY 34075
3/4" VDNY 31073 VDNY 32073 VDNY 33073 VDNY 34073
1001/2" VDNY 31105 VDNY 32105 VDNY 33105 VDNY 34105
3/4" VDNY 31103 VDNY 32103 VDNY 33103 VDNY 34103
1501/2" VDNY 31155 VDNY 32155 VDNY 33155 VDNY 34155
3/4" VDNY 31153 VDNY 32153 VDNY 33153 VDNY 34153
2001/2" VDNY 31205 VDNY 32205 VDNY 33205 VDNY 34205
3/4" VDNY 31203 VDNY 32203 VDNY 33203 VDNY 34203
Metal
Halide
1001/2" VDHY 31105 VDHY 32105 VDHY 33105 VDHY 34105
3/4" VDHY 31103 VDHY 32103 VDHY 33103 VDHY 34103
1751/2" VDHY 31175 VDHY 32175 VDHY 33175 VDHY 34175
3/4" VDHY 31173 VDHY 32173 VDHY 33173 VDHY 34173
Mercury
Vapor
1001/2" VDMY 31105 VDMY 32105 VDMY 33105 VDMY 34105
3/4" VDMY 31103 VDMY 32103 VDMY 33103 VDMY 34103
2001/2" VDMY 31205 VDMY 32205 VDMY 33205 VDMY 34205
3/4" VDMY 31203 VDMY 32203 VDMY 33203 VDMY 34203
* For Pole type, see pole section (2L-51)
Ordering Information
V D N Y 3 1 0 7 5 ① ② ③ ④ ⑤
VDY Lighting Fixture① Mounting Type③ Lamp Wattage (W)④ Entry Size⑤
31 - Pendant 07 - 70 1 - 1"
Lamp Type② 32 - Ceiling 10 - 100 3 - 3/4"
NY - High Pressure Sodium 33 - 90° Bracket 15 - 150 5 - 1/2"
HY - Metal Halide 34 - 40° Bracket 17 - 175
MY - Mercury Vapour 20 - 200
▞ Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<VDNY 32105> 0 160 50 132
5 132 55 132Lamp : NH100 (9000 lm)+
With Globe and Guard+
Reflector : +
White Coating Aluminum
Reflector
10 132 60 132
15 146 65 125
20 160 70 125
25 153 75 111
30 146 80 83.3
35 139 85 27.8
40 139 90 6.9
45 132
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling
Cavity Reflectance( ccρ )80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .84 .84 .84 .82 .82 .82 .78 .78 .78 .75 .75 .75 .72 .72 .72 .70
1 .73 .70 .68 .72 .69 .66 .69 .66 .64 .66 .64 .62 .63 .62 .61 .59
2 .64 .59 .55 .63 .58 .54 .60 .56 .53 .58 .55 .52 .56 .53 .51 .49
3 .56 .50 .46 .55 .50 .45 .53 .48 .44 .51 .47 .44 .49 .46 .43 .41
4 .50 .43 .39 .49 .43 .38 .47 .42 .38 .45 .41 .37 .44 .40 .37 .35
5 .44 .38 .33 .44 .38 .33 .42 .37 .33 .41 .36 .32 .39 .35 .32 .31
6 .40 .34 .29 .39 .33 .29 .38 .33 .29 .37 .32 .28 .36 .32 .28 .27
7 .36 .30 .26 .36 .30 .26 .35 .29 .26 .34 .29 .25 .33 .28 .25 .24
8 .33 .27 .23 .33 .27 .23 .32 .27 .23 .31 .26 .23 .30 .26 .23 .21
9 .31 .25 .21 .30 .25 .21 .29 .24 .21 .29 .24 .21 .28 .24 .21 .19
10 .28 .23 .19 .28 .23 .19 .27 .23 .19 .27 .22 .19 .26 .22 .19 .18
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< VDY Ceiling Type > < VDY 40° Bracket Type >
< VDY Pendant Type > < VDY 90° Bracket Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
VS Series
Wet Locations
NEMA 3, 3R
Application
< VS >
VS Series lighting fixtures are used ;
in manufacturing plants, refineries, chemical,
petrochemical and other industrial process
facilities, wastewater and sewage treatment plants,
offshore, dockside and other harbor installations
as well as other heavy industrial applications.
in industrial areas, both indoors and outdoors
where long life and low maintenance costs are
desired.
Features
The lighting fixture has simple construction.
Relamping is easily done by opening lower half of
the guard and unscrewing the globe.
H.I.D lighting fixture has external type ballast.
Standard Materials Technical Data
Body : Die casting aluminium
Globe : Heat resistant hard glass
External Hardware : Cast aluminium alloy
Electrical Rating
Rated Voltage AC110V/ 220V/ 240V ( See Below)※
Rated Wattage 100W/ 150W/ 175W/ 200W/ 250W/ 400W
Rated Frequency 50Hz/ 60Hz
Compliance Entry Size 1/2", 3/4", 1"
IP55NEMA 3, 3R
Certification
Also you can order various voltage : ※
120V/ 208V/ 277V/ 460V
Certified by KOSHA (Korea Occupational
Safety & Health Agency), KGS (Korea Gas
Safety Corporation), and the others.
Standard Finish Weight
Natural
If you want another color, contact us
please.
Catalog No. Weight
VSNL 7240 18.8 ㎏
Ordering Number Ordering Information
Lamp Watt Pendant Ceiling90°
Bracket
40°
Bracket
V S N L 7 1 1 5
① ② ③ ④ ⑤
High
Pressure
Sodium
100 VSNL7110 VSNL7210 VSNL7310 VSNL7410 VS Lighting Fixture①
150 VSNL7115 VSNL7215 VSNL7315 VSNL7415
200 VSNL7120 VSNL7220 VSNL7320 VSNL7420 Lamp Type②
250 VSNL7125 VSNL7225 VSNL7325 VSNL7425 NL - High Pressure Sodium
400 VSNL7140 VSNL7240 VSNL7340 VSNL7440 HL - Metal Halide
Metal
Halide
100 VSHL7110 VSHL7210 VSHL7310 VSHL7410 ML - Mercury Vapour
175 VSHL7117 VSHL7217 VSHL7317 VSHL7417
250 VSHL7125 VSHL7225 VSHL7325 VSHL7425 Model Type③ Lamp Wattage (W)⑤
400 VSHL7140 VSHL7240 VSHL7340 VSHL7440 7 - VS Type 10 - 100
Mercury
Vapor
100 VSML7110 VSML7210 VSML7310 VSML7410 15 - 150
200 VSML7120 VSML7220 VSML7320 VSML7420 Mounting Type④ 17 - 175
250 VSML7125 VSML7225 VSML7325 VSML7425 1 - Pendant 20 - 200
300 VSML7130 VSML7230 VSML7330 VSML7430 2 - Ceiling 25 - 250
400 VSML7140 VSML7240 VSML7340 VSML7440 3 - 90° Bracket 30 - 300
* For Pole type, see pole section (2L-51) 4 - 40° Bracket 40 - 400
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<VSHL 7217> 0 169.6 50 187.5
5 165.2 55 205.4Lamp : MH175 (14000 lm)+
With Globe and without Guard+ 10 169.6 60 147.3
15 209.8 65 84.8
20 223.2 70 44.6
25 205.4 75 26.8
30 205.4 80 13.4
35 192.0 85 4.5
40 200.9 90 4.5
45 209.8
Coefficients of Utilization - Zonal Cavity%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .90 .90 .90 .88 .88 .88 .84 .84 .84 .80 .80 .80 .77 .77 .77 .76
1 .81 .78 .76 .79 .77 .74 .76 .74 .72 .73 .71 .70 .70 .69 .68 .66
2 .73 .69 .65 .71 .68 .64 .69 .66 .63 .66 .64 .61 .64 .62 .60 .59
3 .66 .60 .56 .64 .60 .56 .62 .58 .55 .60 .57 .54 .59 .56 .53 .52
4 .59 .54 .49 .58 .53 .49 .57 .52 .48 .55 .51 .48 .53 .50 .47 .46
5 .54 .48 .44 .53 .48 .44 .52 .47 .43 .50 .46 .43 .49 .45 .42 .41
6 .49 .43 .39 .48 .43 .39 .47 .42 .39 .46 .42 .38 .45 .41 .38 .37
7 .45 .39 .35 .45 .39 .35 .43 .38 .35 .42 .38 .35 .41 .37 .34 .33
8 .42 .36 .32 .41 .36 .32 .40 .35 .32 .39 .35 .31 .38 .34 .31 .30
9 .38 .33 .29 .38 .33 .29 .37 .32 .29 .36 .32 .29 .36 .32 .29 .27
10 .36 .30 .27 .35 .30 .27 .35 .30 .27 .34 .30 .26 .33 .29 .26 .25
Angle cd/1000 lm Angle cd/1000 lm
<VSNL 7225> 0 302 50 158
5 288 55 155Lamp : NH250 (25000 lm)+
With Globe and without +
Guard
10 235 60 142
15 210 65 108
20 182 70 72.5
25 162 75 47.5
30 165 80 27.5
35 160 85 15.0
40 152 90 7.5
45 155
Coefficients of Utilization - Zonal Cavity%Effective Ceiling Cavity
Reflectance( cc)ρ80 70 50 30 10 0
%Wall
Reflectance(ρw)50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio
RCR20% Effective Floor Cavity Reflectance
0 .83 .83 .83 .81 .81 .81 .77 .77 .77 .74 .74 .74 .71 .71 .71 .70
1 .73 .70 .67 .71 .69 .66 .68 .66 .64 .66 .64 .62 .63 .62 .60 .59
2 .65 .60 .57 .64 .60 .56 .61 .58 .55 .59 .56 .54 .57 .55 .52 .51
3 .58 .53 .49 .57 .52 .48 .55 .51 .47 .53 .49 .47 .51 .48 .46 .44
4 .52 .46 .42 .51 .46 .42 .49 .45 .41 .48 .44 .41 .46 .43 .40 .39
5 .47 .41 .37 .46 .41 .37 .45 .40 .37 .44 .39 .36 .42 .39 .36 .34
6 .43 .37 .33 .42 .37 .33 .41 .36 .33 .40 .36 .32 .39 .35 .32 .31
7 .39 .34 .30 .39 .33 .30 .38 .33 .29 .37 .32 .29 .36 .32 .29 .28
8 .36 .31 .27 .36 .30 .27 .35 .30 .27 .34 .30 .26 .33 .29 .26 .25
9 .34 .28 .25 .33 .28 .25 .32 .28 .24 .32 .27 .24 .31 .27 .24 .23
10 .31 .26 .23 .31 .26 .23 .30 .26 .22 .30 .25 .22 .29 .25 .22 .21
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< VS Ceiling Type > < VS 40° Bracket Type >
< VS Pendant Type > < VS 90° Bracket Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
SR Series
Wet Locations
NEMA 3, 3R, 4, 4X, 7
Type of Explosion-proof
< SR >
Non Sparking (Ex nR II T3)
Application
SR Series lighting fixtures are used ;
in heavy process industries having environments
where flammable or explosive vapors or gases, or
where combustible dusts are present.
in hazardous areas, both indoors and outdoors where
long life and low maintenance costs are desired.
in petroleum refineries, chemical, petrochemical and
other heavy process industry facilities.
where ignitable concentrations of flammable gases,
vapors or liquids can exist all of the time or some of
the time under normal operation conditions.
Features Certification Standard Materials
The globe frame is cast in one
piece with guard.
The globe is sealed into the
globe frame firmly with synthetic
rubber gaskets, and the globe
assembly is fitted to the body by
three socket head captive
screws.
All joint of lamp housing,
including the joint between the
top body and the terminal plate,
are sealed up with high quality
gaskets so as to restrict
breathing.
The body and ballast are
constructed separately so as to
protect the ballast from the heat
of the lamp.
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Enclosure : Aluminium sheet
Globe : Heat resistant hard glass
Globe Frame : Die casting
aluminium alloy
Mounting Box : Cast aluminium
alloy
External Hardware : Stainless
steelCompliance
NEMA 3 ,3R, 4, 4X, 7
IEC 60079-0, 15
IP55
Standard FinishOptions
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
With Choke or Lead Peak type
Ballast
Technical DataWeightElectrical Rating
Rated Voltage AC110V/ 220V/ 240V ( See Below)※ Enclosure Type Catalog No. Weight
Rated Wattage 100W/ 150W/ 175W/ 200W/ 250W/ 400W Small (Ceiling) SRHL 2105 10.3 Kg
Entry Size 1/2", 3/4", 1" Middle (Ceiling) SRHL 2255 19.6 Kg
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp WattHub
SizePendant Ceiling 90° Bracket 40° Bracket Certification
High
Pressure
Sodium
1001/2" SRNL1105 SRNL2105 SRNL3105 SRNL4105
Ex nR II T3
3/4" SRNL1103 SRNL2103 SRNL3103 SRNL4103
1501/2" SRNL1155 SRNL2155 SRNL3155 SRNL4155
3/4" SRNL1153 SRNL2153 SRNL3153 SRNL4153
2001/2" SRNL1205 SRNL2205 SRNL3205 SRNL4205
3/4" SRNL1203 SRNL2203 SRNL3203 SRNL4203
2501/2" SRNL1255 SRNL2255 SRNL3255 SRNL4255
3/4" SRNL1253 SRNL2253 SRNL3253 SRNL4253
4001/2" SRNL1405 SRNL2405 SRNL3405 SRNL4405
3/4" SRNL1403 SRNL2403 SRNL3403 SRNL4403
Metal
Halide
1001/2" SRHL1105 SRHL2105 SRHL3105 SRHL4105
3/4" SRHL1103 SRHL2103 SRHL3103 SRHL4103
1751/2" SRHL1175 SRHL2175 SRHL3175 SRHL4175
3/4" SRHL1173 SRHL2173 SRHL3173 SRHL4173
2501/2" SRHL1255 SRHL2255 SRHL3255 SRHL4255
3/4" SRHL1253 SRHL2253 SRHL3253 SRHL4253
4001/2" SRHL1405 SRHL2405 SRHL3405 SRHL4405
3/4" SRHL1403 SRHL2403 SRHL3403 SRHL4403
Mercury
Vapor
1001/2" SRML1105 SRML2105 SRML3105 SRML4105
3/4" SRML1103 SRML2103 SRML3103 SRML4103
2001/2" SRML1205 SRML2205 SRML3205 SRML4205
3/4" SRML1203 SRML2203 SRML3203 SRML4203
2501/2" SRML1255 SRML2255 SRML3255 SRML4255
3/4" SRML1253 SRML2253 SRML3253 SRML4253
4001/2" SRML1405 SRML2405 SRML3405 SRML4405
3/4" SRML1403 SRML2403 SRML3403 SRML4403
* For Pole type, see pole section (2L-51)
Ordering Information
S R N L 1 1 0 5 ① ② ③ ④ ⑤
SR Lighting Fixture① ③ Mounting Type Lamp Wattage (W)④ Entry Size⑤
1 - Pendant 10 - 100 1 - 1"
Lamp Type② 2 - Ceiling 15 - 150 3 - 3/4"
NL - High Pressure Sodium 3 - 90° Bracket 17 - 175 5 - 1/2"
HL - Metal Halide 4 - 40° Bracket 20 - 200
ML - Mercury Vapour 25 - 250
40 - 400
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<SRNL 2255> 0 170 50 130
5 118 55 102Lamp : NH250 (25000 lm)+
With Globe and Guard + 10 128 60 80.0
15 152 65 50.0
20 175 70 25.0
25 170 75 12.5
30 158 80 7.5
35 148 85 5.0
40 145 90 2.5
45 142
Multipliers Coefficients of Utilization - Zonal Cavity
(For use with
candlepower
curves only)
%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Lamp
Watts
Conversion
Factor
Room Cavity Ratio
RCR20% Effective Floor Cavity Reflectance
0 .59 .59 .59 .58 .58 .58 .55 .55 .55 .53 .53 .53 .51 .51 .51 .50
250 1 1 .53 .52 .50 .52 .51 .49 .50 .49 .48 .48 .47 .46 .46 .46 .45 .44
2 .48 .46 .43 .47 .45 .43 .46 .44 .42 .44 .42 .41 .43 .41 .40 .39
200 0.8 3 .44 .41 .38 .43 .40 .38 .42 .39 .37 .40 .38 .36 .39 .37 .36 .35
4 .40 .36 .34 .39 .36 .34 .38 .35 .33 .37 .35 .33 .36 .34 .32 .31
150 0.6 5 .37 .33 .30 .36 .33 .30 .35 .32 .30 .34 .32 .29 .33 .31 .29 .28
6 .34 .30 .27 .33 .30 .27 .32 .29 .27 .32 .29 .27 .31 .28 .27 .26
100 0.4 7 .31 .27 .25 .31 .27 .25 .30 .27 .25 .29 .26 .24 .29 .26 .24 .23
8 .29 .25 .23 .28 .25 .23 .28 .25 .22 .27 .24 .22 .27 .24 .22 .21
9 .27 .23 .21 .26 .23 .21 .26 .23 .21 .25 .23 .21 .25 .22 .21 .20
10 .25 .22 .19 .25 .21 .19 .24 .21 .19 .24 .21 .19 .23 .21 .19 .18
Angle cd/1000 lm Angle cd/1000 lm
<SRHL2255> 0 203 50 220
5 168 55 204Lamp : MH250 (20500 lm)+
With Globe and Guard + 10 156 60 137
15 143 65 57.9
20 152 70 27.4
25 174 75 12.2
30 213 80 6.1
35 238 85 3.0
40 229 90 3.0
45 229
Multipliers Coefficients of Utilization - Zonal Cavity
(For use with
candlepower
curves only)
%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall
Reflectance(ρw)50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Lamp
Watts
Conversion
FactorRoom Cavity Ratio
RCR20% Effective Floor Cavity Reflectance
0 .86 .86 .86 .84 .84 .84 .80 .80 .80 .77 .77 .77 .74 .74 .74 .72
250 1 1 .77 .75 .72 .76 .73 .71 .73 .71 .69 .70 .68 .67 .67 .66 .65 .64
2 .70 .66 .63 .69 .65 .62 .66 .63 .61 .64 .61 .59 .62 .60 .58 .57
175 0.68 3 .63 .58 .55 .62 .58 .54 .60 .56 .53 .58 .55 .52 .56 .54 .51 .50
4 .57 .52 .48 .56 .51 .48 .55 .50 .47 .53 .49 .46 .52 .48 .46 .45
5 .52 .46 .42 .51 .46 .42 .50 .45 .42 .48 .45 .41 .47 .44 .41 .40
6 .47 .42 .38 .47 .41 .38 .46 .41 .37 .44 .40 .37 .43 .40 .37 .35
7 .43 .38 .34 .43 .38 .34 .42 .37 .34 .41 .37 .33 .40 .36 .33 .32
8 .40 .34 .31 .39 .34 .31 .38 .34 .30 .38 .33 .30 .37 .33 .30 .29
9 .37 .31 .28 .36 .31 .28 .36 .31 .28 .35 .31 .27 .34 .30 .27 .26
10 .34 .29 .25 .34 .29 .25 .33 .28 .25 .32 .28 .25 .32 .28 .25 .24
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< SR 90° Bracket Type > < SR 40° Bracket Type >
< SR Ceiling Type > < SR Pendant Type >
LAMP WATTCeiling Type Pendant Type 90° Bracket 40° Bracket
A BØ A BØ A BØ A BØ C
Max. 100W 550 275 310 275 420 275 650 275 345
Max. 250W 640 340 400 340 510 340 710 340 400
Max. 400W 695 385 455 385 565 385 750 385 430
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
V Series H.I.D Lighting Fixtures
VG, VN, VZ Series
Wet Locations
Marine Locations
NEMA 3,3R,4,4X,7
< VG > < VN > < VZ >
Type of Explosion-proof Fixture Wattage
Class I Division 2 Group A,B,C,D
Class II Division 1,2 Group E,F,G
Class III Division 1
Simultaneous Presence (VN Series)
Non Sparking (Ex nR II T4 IP66)
Dust Ignition-proof (Ex DP II 11)
Lamp V Series Wattage
Type VG VN VZ
HPS 50, 70, 100 150, 200, 250 250, 400
MH 100 175, 250 250, 400
MV 100 200, 250 250, 400
Application in hazardous locations requiring
elevated ambient capability.
in installations where moisture,
dirt, dust, vibration, corrosion
and rough usage are problems.
Four mounting arrangements to
suit any lighting layout pendant,
ceiling, wall bracket and stanchion.
Internal ballasts-separate ballasts
are not required. High power
factor (90%) ballasts reduce
power costs allow more fixtures
per circuit.
Cast aluminium alloy construction
and epoxy powder finish provide
excellent resistant to corrosion.
V Series HID lighting fixtures are
used ;
in heavy process industries
having environments where
flammable or explosive vapors or
gases, or where combustible
dusts are present.
in hazardous areas, both indoors
and outdoors where long life
and low maintenance costs are
desired.
in petroleum refineries, chemical,
petrochemical and other heavy
process industry facilities.
in paint spray booth suitability
provides efficient, economical
HID lighting for paint spray
areas.
where ignitable concentrations of
flammable gases, vapors or
liquids can exist all of the time
or some of the time under
normal operation conditions.
Features
Hinged ballast housing for ease
of installation and maintenance
Hubs with integral conduit stop
and bushing to help prevent
damage to field wiring during
installation.
Factory sealed, porcelain with
mogul or medium base socket.
Dome and 30°angle reflectors
made of FRP material won't rust,
corrode, dent, chip or peel.
If you need more data, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
V Series H.I.D Lighting Fixtures
VG Series
Wet Locations
Marine Locations
NEMA 3,3R,4,4X,7
Type of Explosion-proof
Non Sparking (Ex nR II T4 IP66)
Class I Division 2 Group A,B,C,D
Features Standard Materials
Compact, lightweight design is ideal for medium and
low mounting heights.
Cast aluminium alloy construction and epoxy powder
finish provide excellent resistant to corrosion.
Hubs with integral conduit stop and bushing to help
prevent damage to field wiring during installation.
Restricted Breathing Construction : zone 2 only
Enclosure : Die casting aluminium
Globe : Heat resistant hard glass
Lamp socket : Porcelain with screw shell
Reflector : High grade aluminium sheet
Guard : Die casting aluminium
Compliance & Certification
< VG >
NEC - Class I Division 2 Group A,B,C,D
UL 844 - Lighting Fixtures for Use in Hazardous
(Classified) Locations
UL Listed File No. E 131747
IEC 60079-0, 15
NEMA 3, 3R, 4, 4X, 7
Certified by UL (Underwriters Laboratories Inc.),
KOSHA (Korea Occupational Safety & Health
Agency), KGS (Korea Gas Safety Corporation), and
the others.
Options
With Dome Reflector or 30° Angle Reflector
Instant Restrike (HPS only)
Fused to protect ballast and capacitors
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated Voltage
AC110V/ 220V/ 240V Ceiling VGNL 22103 7.7 ㎏
(110V/ 120V/ 208V/ 220V/
240V/ 277V for UL Listed)
Rated Wattage 50W/ 70W/ 100W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp WattHub
SizePendant Ceiling Bracket Stanchion Certification
High
Pressure
Sodium
501" VGNL 12051 VGNL 22051 VGNL 32051 VGNL 92051
Ex nR II T4 IP66
Class I Division 2
Group A,B,C,D
3/4" VGNL 12053 VGNL 22053 VGNL 32053 VGNL 92053
701" VGNL 12071 VGNL 22071 VGNL 32071 VGNL 92071
3/4" VGNL 12073 VGNL 22073 VGNL 32073 VGNL 92073
1001" VGNL 12101 VGNL 22101 VGNL 32101 VGNL 92101
3/4" VGNL 12103 VGNL 22103 VGNL 32103 VGNL 92103
Metal
Halide100
1" VGHL 12101 VGHL 22101 VGHL 32101 VGHL 92101
Ex nR II T3 IP66
Class I Division 2
Group A,B,C,D
3/4" VGHL 12103 VGHL 22103 VGHL 32103 VGHL 92103
Mercury
Vapor100
1" VGML 12101 VGML 22101 VGML 32101 VGML 92101
3/4" VGML 12103 VGML 22103 VGML 32103 VGML 92103
Ordering Information Dimension
<Bracket Type>
<Stanchion Type>
<Ceiling Type>
<Pendant Type>
V G N L 1 2 0 5 1 - DR ① ② ③ ④ ⑤ ⑥ ⑦
VG Lighting Fixture① Lamp Wattage (W)⑤
05 - 50
Lamp Type② 07 - 70
NL - High Pressure Sodium 10 - 100
HL - Metal Halide
ML - Mercury Vapour
Mounting Type③ Entry Size⑥
1 - Pendant 1 - 1"
2 - Ceiling 3 - 3/4"
3 - Bracket 5 - 1/2"
9 - Stanchion
Input Voltage (V)④
1 - 120 Options⑦
2 - 220 DR - Dome Type Reflector
3 - 110 AR - Angle Type Reflector
4 - 208
5 - 277 IR - Instant Restrike
6 - 240 FU - Fused Type
7 - 230
Temperature Performance Data
Lamp Ambient Class I Non-Sparking
Type Watt. Temp ( )℃ Div. 2 "nR"
High
Pressure
Sodium
5040 260 (T2B) T4
55 - T4
7040 260 (T2B) T4
55 - T4
10040 260 (T2B) T4
55 - T4
Metal
Halide100
40 - T3
55 - T3
Mercury
Vapor100
40 280 (T2A) T4
55 - T4
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<VGNL 12101-DR> 0 78.7 50 262.4
5 77.8 55 239.1Lamp : NH100 (9000 lm)+
With Guard+
Reflector : +
Aluminium Dome type
Reflector
10 79.7 60 199.7
15 88.2 65 169.7
20 111.5 70 158.5
25 135.9 75 113.4
30 157.5 80 65.6
35 189.4 85 23.5
40 218.4 90 13.1
45 248.4
Multipliers Coefficients of Utilization - Zonal Cavity(For use with
candlepower
curves only)
%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Lamp
Watts
Conversion
Factor
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .91 .91 .91 .89 .89 .89 .85 .85 .85 .81 .81 .81 .78 .78 .78 .77
1 .78 .75 .72 .77 .73 .70 .73 .71 .68 .70 .68 .66 .68 .66 .64 .62
100 1 2 .67 .61 .57 .66 .60 .56 .63 .58 .55 .60 .57 .53 .58 .55 .52 .50
3 .58 .51 .46 .57 .50 .45 .54 .49 .44 .52 .48 .44 .50 .46 .43 .41
70 0.5 4 .51 .43 .38 .50 .43 .38 .48 .42 .37 .46 .41 .37 .44 .40 .36 .34
5 .45 .38 .32 .44 .37 .32 .42 .36 .32 .41 .35 .31 .39 .35 .31 .29
50 0.25 6 .40 .33 .28 .39 .33 .28 .38 .32 .27 .37 .31 .27 .35 .31 .27 .25
7 .36 .29 .24 .36 .29 .24 .34 .28 .24 .33 .28 .24 .32 .27 .24 .22
8 .33 .26 .22 .32 .26 .21 .31 .26 .21 .30 .25 .21 .30 .25 .21 .19
9 .30 .24 .19 .30 .24 .19 .29 .23 .19 .28 .23 .19 .27 .22 .19 .17
10 .28 .22 .17 .28 .22 .17 .27 .21 .17 .26 .21 .17 .25 .21 .17 .16
Angle cd/1000 lm Angle cd/1000 lm
<VGHL 12101-DR> 0 90.9 50 199.9
5 90.9 55 164.8Lamp : MH100 (6500 lm)+
With Guard+
Reflector : +
Aluminium Dome type
Reflector
10 94.8 60 144.0
15 114.2 65 132.4
20 133.7 70 48.1
25 177.8 75 27.3
30 218.0 80 16.9
35 266.1 85 11.7
40 266.1 90 9.0
45 245.3
Coefficients of Utilization - Zonal Cavity%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .95 .95 .95 .93 .93 .93 .89 .89 .89 .85 .85 .85 .82 .82 .82 .80
1 .86 .83 .80 .84 .81 .79 .81 .78 .77 .77 .76 .74 .75 .73 .72 .70
2 .77 .72 .68 .75 .71 .67 .72 .69 .66 .70 .67 .64 .68 .65 .63 .61
3 .69 .63 .59 .67 .62 .58 .62 .61 .57 .63 .59 .56 .61 .58 .55 .54
4 .62 .56 .51 .61 .55 .50 .59 .54 .50 .57 .53 .49 .55 .52 .49 .47
5 .56 .49 .44 .55 .49 .44 .53 .48 .44 .52 .47 .43 .50 .46 .43 .41
6 .50 .44 .39 .50 .44 .39 .48 .43 .39 .47 .42 .38 .46 .42 .38 .37
7 .46 .40 .35 .45 .39 .35 .44 .39 .35 .43 .38 .34 .42 .38 .34 .33
8 .42 .36 .31 .42 .35 .31 .41 .35 .31 .40 .35 .31 .39 .34 .31 .29
9 .39 .32 .28 .38 .32 .28 .37 .32 .28 .36 .32 .28 .36 .31 .28 .26
10 .36 .30 .26 .35 .30 .26 .35 .29 .26 .34 .29 .25 .33 .29 .25 .24
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
V Series H.I.D Lighting Fixtures
VN Series
Wet Locations
Marine Locations
NEMA 3,3R,4,4X,7,9
< VN >
Type of Explosion-proof
Non Sparking (Ex nR II T3 IP66)
Dust Ignition-proof (Ex DP II 11)
Class I Division 2 Group A,B,C,D
Class II Division 1,2 Group E,F,G
Class III Division 1
Features
Compact, lightweight design is ideal for medium
and low mounting heights.
Wide range of light sources to meet specific
lighting needs - High Pressure Sodium (HPS):
150, 200 and 250W, Mercury Vapour (MV): 200
and 250W, Metal Halide (MH): 175 and 250W.
Restricted Breathing Construction : Zone 2 only
Standard Materials
Enclosure : Die casting aluminium
Globe : Heat resistant hard glass
Lamp socket :
Porcelain with screw shell
Reflector : Aluminium sheet /
Fiberglass-Reinforced Polyester
Guard : Stainless steel
Certification Compliance Options
UL Listed File No. E 131747
Certified by UL (Underwriters
Laboratories Inc.), KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
NEC - Class I Division 2 Group
A,B,C,D, / Class II Division 1,2
Group E,F,G / Class III Division 1
UL 844 - Lighting Fixtures for Use
in Hazardous (Classified) Locations
IEC 60079-0, 15
NEMA 3, 3R, 4, 4X, 7, 9
With Dome Reflector or 30°
Angle Reflector
Instant Restrike (HPS only)
Fused to protect ballast and
capacitors
Quartz Auxiliary Lighting come
to full brightness immediately
(Non-hazardous location only)Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact
us please.
Technical Data WeightElectrical Rating
Mounting Type Catalog No. Weight
Rated Voltage
AC110V/ 220V/ 240V
(110V/ 120V/ 208V/ 220V/
240V/ 277V for UL Listed)Pendant VNNL 12153 12.6 ㎏
Ceiling VNNL 22153 12.8 ㎏Rated Wattage 150W/ 175W/ 200W/ 250W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp WattHub
SizePendant Ceiling Bracket Stanchion Certification
High
Pressure
Sodium
1501" VNNL 12151 VNNL 22151 VNNL 32151 VNNL 92151
Ex nR II T3 IP66
Ex DP II 11
3/4" VNNL 12153 VNNL 22153 VNNL 32153 VNNL 92153
2001" VNNL 12201 VNNL 22201 VNNL 32201 VNNL 92201
3/4" VNNL 12203 VNNL 22203 VNNL 32203 VNNL 92203
2501" VNNL 12251 VNNL 22251 VNNL 32251 VNNL 92251
3/4" VNNL 12253 VNNL 22253 VNNL 32253 VNNL 92253
Metal
Halide
1751" VNHL 12171 VNHL 22171 VNHL 32171 VNHL 92171
Ex nR II T3 IP66
Ex DP II 12 IP66
3/4" VNHL 12173 VNHL 22173 VNHL 32173 VNHL 92173
2501" VNHL 12251 VNHL 22251 VNHL 32251 VNHL 92251
3/4" VNHL 12253 VNHL 22253 VNHL 32253 VNHL 92253
Mercury
Vapor
2001" VNML 12201 VNML 22201 VNML 32201 VNML 92201
Ex nR II T4 IP66
Ex DP II 11
3/4" VNML 12203 VNML 22203 VNML 32203 VNML 92203
2501" VNML 12251 VNML 22251 VNML 32251 VNML 92251
3/4" VNML 12253 VNML 22253 VNML 32253 VNML 92253
Ordering Information
V N N L 1 2 1 5 1 - DR① ② ③ ④ ⑤ ⑥ ⑦
VN Lighting Fixture① Lamp Type② Mounting Type③ Input Voltage (V)④
NL - High Pressure Sodium 1 - Pendant 1 - 120
HL - Metal Halide 2 - Ceiling 2 - 220
ML - Mercury Vapour 3 - Bracket 3 - 110
9 - Stanchion 4 - 208
Lamp Wattage (W)⑤ : Entry Size⑥ Options⑦ 5 - 277
15 - 150 1 - 1" DR - Dome Type Reflector 6 - 240
17 - 175 3 - 3/4" AR - Angle Type Reflector 7 - 230
20 - 200 5 - 1/2" IR - Instant Restrike Type
25 - 250 FU - Fused Type
QAL - Quartz Auxiliary Lighting Type
Temperature Performance Data
Lamp Ambient Class I Class II Non-Sparking Dust Ignition
Type Watt. Temp ( )℃ Div. 2 Div. 1 "nR" Proof "DP"
High
Pressure
Sodium
15040 260 (T2B) 160 (T2C) T3 11
55 - - T3 -
20040 260 (T2B) 160 (T2C) T3 11
55 - - T3 -
25040 260 (T2B) 160 (T2C) T3 11
55 - - T3 -
Metal
Halide
17540 - 160 (T2C) T3 11
55 - T3 -
25040 300 (T2) 160 (T2C) T3 11
55 - - T3 -
Mercury
Vapor
20040 325 (T1) 165 (T2B) T4 11
55 - - - -
25040 325 (T1) 165 (T2B) T4 11
55 - - - -
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<VNNL 12251-DR> 0 91.0 50 136
5 91.0 55 140Lamp : NH250 (25000 lm)+
With Guard+
Reflector : +
FRP Dome Reflector
10 91.0 60 140
15 107 65 140
20 123 70 143
25 130 75 136
30 130 80 110
35 127 85 68.3
40 130 90 22.8
45 133
Multipliers Coefficients of Utilization - Zonal Cavity
(For use with
candlepower
curves only)
%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Lamp
Watts
Conversion
Factor
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .91 .91 .91 .89 .89 .89 .85 .85 .85 .81 .81 .81 .78 .78 .78 .77
1 .78 .75 .72 .77 .73 .70 .73 .71 .68 .70 .68 .66 .68 .66 .64 .62
250 1 2 .67 .61 .57 .66 .60 .56 .63 .58 .55 .60 .57 .53 .58 .55 .52 .50
3 .58 .51 .46 .57 .50 .45 .54 .49 .44 .52 .48 .44 .50 .46 .43 .41
200 0.8 4 .51 .43 .38 .50 .43 .38 .48 .42 .37 .46 .41 .37 .44 .40 .36 .34
5 .45 .38 .32 .44 .37 .32 .42 .36 .32 .41 .35 .31 .39 .35 .31 .29
150 0.56 6 .40 .33 .28 .39 .33 .28 .38 .32 .27 .37 .31 .27 .35 .31 .27 .25
7 .36 .29 .24 .36 .29 .24 .34 .28 .24 .33 .28 .24 .32 .27 .24 .22
8 .33 .26 .22 .32 .26 .21 .31 .26 .21 .30 .25 .21 .30 .25 .21 .19
9 .30 .24 .19 .30 .24 .19 .29 .23 .19 .28 .23 .19 .27 .22 .19 .17
10 .28 .22 .17 .28 .22 .17 .27 .21 .17 .26 .21 .17 .25 .21 .17 .16
Angle cd/1000 lm Angle cd/1000 lm
<VNHL 12251-DR> 0 102 50 130
5 102 55 140Lamp : MH250 (20500 lm)+
With Guard+
Reflector : +
FRP Dome Reflector
10 98.2 60 144
15 119 65 144
20 133 70 144
25 133 75 144
30 137 80 130
35 133 85 59.6
40 140 90 10.5
45 126
Multipliers Coefficients of Utilization - Zonal Cavity
(For use with
candlepower
curves only)
%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Lamp
Watts
Conversion
Factor
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .92 .92 .92 .90 .90 .90 .86 .86 .86 .82 .82 .82 .79 .79 .79 .77
1 .79 .76 .73 .78 .74 .71 .74 .72 .69 .71 .69 .67 .68 .67 .65 .63
250 1 2 .68 .62 .58 .67 .61 .57 .64 .59 .55 .61 .57 .54 .59 .56 .53 .51
3 .59 .52 .47 .58 .51 .46 .55 .50 .45 .53 .48 .44 .51 .47 .44 .42
175 0.68 4 .52 .44 .39 .50 .44 .38 .48 .43 .38 .47 .41 .37 .45 .40 .37 .35
5 .46 .38 .33 .45 .38 .33 .43 .37 .32 .41 .36 .32 .40 .35 .31 .30
6 .41 .34 .28 .40 .33 .28 .39 .32 .28 .37 .32 .28 .36 .31 .27 .26
7 .37 .30 .25 .36 .29 .25 .35 .29 .24 .34 .28 .24 .33 .28 .24 .22
8 .34 .27 .22 .33 .27 .22 .32 .26 .22 .31 .26 .22 .30 .25 .22 .20
9 .31 .24 .20 .30 .24 .20 .30 .24 .20 .29 .23 .20 .28 .23 .19 .18
10 .29 .22 .18 .28 .22 .18 .27 .22 .18 .27 .21 .18 .26 .21 .18 .16
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< VN Bracket Type > < VN Stanchion Type >
< VN Ceiling Type > < VN Pendant Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
V Series H.I.D Lighting Fixtures
VZ Series
Wet Locations
Marine Locations
NEMA 3,3R,4,4X,7,9
Type of Explosion-proof
Non Sparking (Ex nR II T2 IP66)
Class I Division 2 Group A,B,C,D
Class II Division 1,2 Group E,F,G
Class III Division 1
Features Standard Materials
Low ambient capability to -40℃
Wide range of light sources to
meet specific lighting needs - High
Pressure Sodium (HPS): 250 and
400W, Mercury Vapour (MV): 250
and 400W, Metal Halide (MH): 250
and 400W
Restricted Breathing Construction :
Zone 2 only
< VZ >
Enclosure : Die casting aluminium
Globe : Heat resistant hard glass
Lamp socket :
Porcelain with screw shell
Reflector :
Aluminium sheet /
Fiberglass-Reinforced Polyester
Guard : Stainless steel
Certification
UL Listed File No. E 131747
Certified by UL (Underwriters
Laboratories Inc.), KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Options
With Dome Reflector or 30° Angle
Reflector
Fused to protect ballast and
capacitors
Quartz Auxiliary Lighting come to
full brightness immediately
(Non-hazardous location only)
Compliance NEC - Class I Division 2 Group
A,B,C,D, / Class II Division 1,2
Group E,F,G / Class III Division 1
UL 844 - Lighting Fixtures for Use
in Hazardous (Classified) Locations
IEC 60079-0, 15
NEMA 3, 3R, 4, 4X, 7, 9
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact
us please.
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated VoltageAC110V/ 220V/ 240V
( See Below)※Bracket VZNL 32253 18.8 ㎏
Rated Wattage 250W/ 400W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
Also you can order various voltage : ※ 120V/ 208V/ 277V/ 460V
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp WattHub
SizePendant Ceiling Bracket Stanchion Certification
High
Pressure
Sodium
2501" VZNL 12251 VZNL 22251 VZNL 32251 VZNL 92251
Ex nR II T33/4" VZNL 12253 VZNL 22253 VZNL 32253 VZNL 92253
4001" VZNL 12401 VZNL 22401 VZNL 32401 VZNL 92401
Ex nR II T23/4" VZNL 12403 VZNL 22403 VZNL 32403 VZNL 92403
Metal
Halide
2501" VZHL 12251 VZHL 22251 VZHL 32251 VZHL 92251
Ex nR II T33/4" VZHL 12253 VZHL 22253 VZHL 32253 VZHL 92253
4001" VZHL 12401 VZHL 22401 VZHL 32401 VZHL 92401
Ex nR II T23/4" VZHL 12403 VZHL 22403 VZHL 32403 VZHL 92403
Mercury
Vapor
2501" VZML 12251 VZML 22251 VZML 32251 VZML 92251
Ex nR II T33/4" VZML 12253 VZML 22253 VZML 32253 VZML 92253
4001" VZML 12401 VZML 22401 VZML 32401 VZML 92401
Ex nR II T23/4" VZML 12403 VZML 22403 VZML 32403 VZML 92403
Ordering Information
V Z N L 1 2 2 5 1 - DR ① ② ③ ④ ⑤ ⑥ ⑦
VZ Lighting Fixture① Lamp Type② Mounting Type③ Input Voltage (V)④
NL - High Pressure Sodium 1 - Pendant 1 - 120
HL - Metal Halide 2 - Ceiling 2 - 220
ML - Mercury Vapour 3 - Bracket 3 - 110
9 - Stanchion 4 - 208
5 - 277
Lamp Wattage (W)⑤ Entry Size⑥ Options⑦ 6 - 240
25 - 250 1 - 1" DR - Dome Type Reflector 7 - 230
40 - 400 3 - 3/4" AR - Angle Type Reflector
5 - 1/2" FU - Fused Type
QAL - Quartz Auxiliary Lighting Type
Temperature Performance Data
Lamp Ambient Non Sparking
Type Watt. Temp ( )℃ "nR"
High
Pressure
Sodium
25040 T3
55 T3
40040 T2
55 T2
Metal
Halide
25040 T3
55 T3
40040 T2
55 T2
Mercury
Vapor
25040 T3
55 T3
40040 T2
55 T2
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
0 13.9 50 86.3<VZNL 22401-DR>
5 14.7 55 93.6Lamp : NH400 (46000 lm)+
With Globe and without Guard+
Reflector : +
FRP Dome Reflector
10 15.7 60 92.5
15 27.5 65 97.2
20 36.7 70 100
25 40.4 75 104
30 45.0 80 104
35 50.6 85 106
40 70.1 90 106
45 77.9
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%WallReflectance(ρw)
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity RatioRCR
20% Effective Floor Cavity Reflectance
0 .63 .63 .63 .61 .61 .61 .58 .58 .58 .56 .56 .56 .54 .54 .54 .53
1 .52 .49 .47 .51 .48 .46 .49 .46 .44 .46 .45 .43 .44 .43 .42 .40
2 .43 .38 .34 .42 .38 .34 .40 .36 .33 .38 .35 .32 .36 .34 .31 .30
3 .36 .31 .26 .35 .30 .26 .33 .29 .25 .32 .28 .25 .30 .27 .24 .23
4 .31 .25 .21 .30 .25 .21 .29 .24 .20 .27 .23 .20 .26 .22 .20 .18
5 .27 .21 .17 .26 .21 .17 .25 .20 .17 .24 .20 .16 .23 .19 .16 .15
6 .24 .18 .14 .23 .18 .14 .22 .17 .14 .21 .17 .14 .20 .16 .13 .12
7 .21 .16 .12 .21 .15 .12 .20 .15 .12 .19 .15 .12 .18 .14 .11 .10
8 .19 .14 .10 .18 .14 .10 .18 .13 .10 .17 .13 .10 .16 .13 .10 .09
9 .17 .12 .09 .17 .12 .09 .16 .12 .09 .16 .12 .09 .15 .11 .09 .08
10 .16 .11 .08 .15 .11 .08 .15 .11 .08 .14 .10 .08 .14 .10 .08 .07
Angle cd/1000 lm Angle cd/1000 lm
0 19.3 50 115<VZHL 22401-DR>
5 20.7 55 111Lamp : MH400 (34000 lm)+
With Globe and without Guard+
Reflector : +
FRP Dome Reflector
10 22.1 60 113
15 30.2 65 119
20 43.2 70 124
25 54.4 75 128
30 53.9 80 131
35 68.4 85 134
40 67.8 90 139
45 105
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%WallReflectance(ρw)
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity RatioRCR
20% Effective Floor Cavity Reflectance
0 .79 .79 .79 .77 .77 .77 .73 .73 .73 .70 .70 .70 .67 .67 .67 .66
1 .65 .62 .58 .64 .61 .58 .61 .58 .56 .58 .56 .54 .56 .54 .52 .51
2 .54 .48 .43 .53 .47 .43 .50 .46 .42 .48 .44 .41 .46 .42 .40 .38
3 .45 .38 .33 .44 .38 .33 .42 .37 .32 .40 .35 .31 .38 .34 .31 .29
4 .39 .32 .26 .38 .31 .26 .36 .30 .26 .34 .29 .25 .33 .28 .25 .23
5 .34 .27 .21 .33 .26 .21 .31 .25 .21 .30 .25 .21 .29 .24 .20 .19
6 .30 .23 .18 .29 .23 .18 .28 .22 .18 .27 .21 .17 .25 .21 .17 .16
7 .27 .20 .15 .26 .20 .15 .25 .19 .15 .24 .19 .15 .23 .18 .15 .13
8 .24 .17 .13 .23 .17 .13 .22 .17 .13 .22 .16 .13 .21 .16 .13 .11
9 .22 .16 .11 .21 .15 .11 .20 .15 .11 .20 .15 .11 .19 .14 .11 .10
10 .20 .14 .10 .19 .14 .10 .19 .14 .10 .18 .13 .10 .17 .13 .10 .09
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< VZ Bracket Type > < VZ Ceiling Type >
< VZ Stanchion Type > < VZ Pendant Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
V Series H.I.D Lighting Fixtures
Auxiliary Lighting
< Auxiliary Lighting >
About Auxiliary Lighting Features V Series Auxiliary Lighting
Momentary voltage outages or dips
can temporarily extinguish HID
lamps which may require up to ten
minutes to restrike. To provide
illumination during this period,
10~20% of the fixtures should be
specified with auxiliary lighting.
Hinged ballast housing for ease
of installation and maintenance
Hubs with integral conduit stop
and bushing to help prevent
damage to field wiring during
installation.
Factory sealed, porcelain with
mogul or medium base socket.
Four mounting arrangements to
suit any lighting layout pendant,
ceiling, wall bracket and
stanchion.
Internal ballasts-separate ballasts
are not required. High power
factor (90%) ballasts reduce
power costs allow more fixtures
per circuit.
Cast aluminium alloy
construction and epoxy powder
finish provide excellent resistant
to corrosion.
Quartz auxiliary is available for
all V Series fixtures (except
those with plastic refractors) by
adding the suffix QAL to the
fixture catalog number.
(Example :
VN NL 1 2 15 1- QAL)
Series VG fixtures with this
option use 100 or 150 watt
quartz lamps. Series VN wattage
fixtures can use up to 250 watt
quartz lamps. Quartz lamps are
not supplied with the fixture
Due to the quartz envelope
surface temperature (exceeding
6000°C), fixtures with this option
are not suitable for Wet
hazardous locations. Contact the
Factory for specific fixture
suitabilities.
Instant Restart
Available for 70-150 Watt VG Series
High Pressure Sodium Fixtures by
adding Suffix "IR" to catalog
number (Ex: VN NL 1 2 15 1 - IR).
Additional instant restart interior
circuitry may decrease High
Pressure Sodium lamp life. Feature
will not affect fixture suitability in
hazardous location applications
Incandescent Auxiliary
With a surface lamp temperature
lower than quartz, incandescent
auxiliary lamps are available for
Series V fixtures.
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
EVN Series
Wet Locations
NEMA 3,3R,4,4X,7,9
Type of Explosion-proof Technical Data
Flameproof-Non Sparking (Ex dnR IIC T4)
Non Sparking (Ex nR II T4 IP66)
Dust Ignition-proof (Ex DP II 11 IP66)
Electrical Ratings
Rated Voltage AC110V/ 220V/ 240V ( See Below)※
Rated Wattage 50W/ 70W/ 100W/ 150W/
175W/ 200W/ 250W
Rated Frequency 50Hz/ 60HzWeightEntry Sizes 1/2", 3/4", 1"
Mounting Type Catalog No. WeightAlso you can order various voltage : ※
120V/ 208V/ 277V/ 460VPendant EVNNL 1255 11.5 Kg
< EVN >
Standard Finish
Dark Gray
If you want another color, contact us
please.
Certification
Certified by KOSHA (Korea
Occupational Safety & Health Agency),
KGS (Korea Gas Safety Corporation),
and the others.
Compliance
IEC 60079-0, 1, 15
NEMA 3, 3R, 4, 4X, 7, 9
Options
With Dome Reflector or 30°
Angle Reflector with SMC or High
Grade Aluminium
With Choke or Lead Peak type
Ballast
For various voltage from 110V to
240V
For 50Hz/ 60Hz
Application Features
EVN Series lighting fixtures are used ;
in manufacturing plants, refineries,
chemical, petrochemical and other
industrial process facilities, wastewater
and sewage treatment plants, offshore,
dockside and other harbor installations as
well as other heavy industrial applications.
wherever the damaging effects of water,
wind, snow, sleet, hot sun or any
combination of these elements are found.
in withstands the harshest of corrosive
environments.
to provide low wattage spot and
floodlighting.
where an explosive atmosphere consisting
of a mixture with air of flammable
substances in the form of gas, vapour or
mist is not likely to occur in normal
operation but, if it does occur, will persist
for a short period only.
where combustible dust, moisture, dirt are
present and vibration, corrosion, rough
usage are problems.
Enclosure in glass fiber
reinforced polyester resin,
provide excellent resistant to
corrosion so have a long life.
Enclosure contain ultraviolet
interception ingredient to
resist transformation.
Easy installation and
maintenance.
Pendant mounting module
equipped with integral hub
set screws for vibration
resistance.
Guard, hub inserts, stanchion
elbow and hardware made of
stainless steel for maximum
resistance to corrosion.
Grounding wire for safety.
Hinged assembly allows the
fixture to hang free during
installation to permit the use
of both hands when wiring.
Standard Materials
Housing, mounting modules,
component pallets : Fiberglass
reinforced polyester resin
Globe : Heat resistant hard glass
Gasket : Silicone rubber
Reflector : Fiberglass Reinforced
Polyester
External Hardware : Stainless
steel, Brass
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt Hub Size Pendant Ceiling Bracket Stanchion Certification
High
Pressure
Sodium
501/2" EVNNL 1055 EVNNL 2055 EVNNL 3055 EVNNL 9055
Ex dnR IIC T4 IP66
Ex nR II T4 IP66
Ex DP II 11 IP66
3/4" EVNNL 1053 EVNNL 2053 EVNNL 3053 EVNNL 9053
701/2" EVNNL 1075 EVNNL 2075 EVNNL 3075 EVNNL 9075
3/4" EVNNL 1073 EVNNL 2073 EVNNL 3073 EVNNL 9073
1001/2" EVNNL 1105 EVNNL 2105 EVNNL 3105 EVNNL 9105
3/4" EVNNL 1103 EVNNL 2103 EVNNL 3103 EVNNL 9103
1501/2" EVNNL 1155 EVNNL 2155 EVNNL 3155 EVNNL 9155
3/4" EVNNL 1153 EVNNL 2153 EVNNL 3153 EVNNL 9153
2001/2" EVNNL 1205 EVNNL 2205 EVNNL 3205 EVNNL 9205
3/4" EVNNL 1203 EVNNL 2203 EVNNL 3203 EVNNL 9203
2501/2" EVNNL 1255 EVNNL 2255 EVNNL 3255 EVNNL 9255
3/4" EVNNL 1253 EVNNL 2253 EVNNL 3253 EVNNL 9253
Metal
Halide
1001/2" EVNHL 1105 EVNHL 2105 EVNHL 3105 EVNHL 9105
Ex dnR IIC T4 IP66
Ex nR II T3 IP66
Ex DP II 11 IP66
3/4" EVNHL 1103 EVNHL 2103 EVNHL 3103 EVNHL 9103
1751/2" EVNHL 1175 EVNHL 2175 EVNHL 3175 EVNHL 9175
3/4" EVNHL 1173 EVNHL 2173 EVNHL 3173 EVNHL 9173
2501/2" EVNHL 1255 EVNHL 2255 EVNHL 3255 EVNHL 9255 Ex dnR IIC T3 IP66
Ex nR II T3 IP663/4" EVNHL 1253 EVNHL 2253 EVNHL 3253 EVNHL 9253
Ordering Information Dimension
E VN N L 1 0 5 5 - DR ① ② ③ ④ ⑤ ⑥
EVN Lighting Fixture① Lamp Type②
NL - High Pressure Sodium
Mounting Type③ HL - Metal Halide
1 - Pendant ML - Mercury Vapour
2 - Ceiling
3 - Bracket Lamp Wattage (W)④
9 - Stanchion 05 - 50
07 - 70
Entry Size⑤ 10 - 100
1 - 1" 15 - 150
3 - 3/4" 17 - 175
5 - 1/2" 20 - 200
25 - 250
Options⑥
DR - Dome Reflector
AR - Angle Reflector
C※ an order Aluminium Reflector instead of FRP Reflector
< Pendant Type > < Ceiling Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<EVNNL 2255-DR> 0 81.0 50 135
5 81.0 55 138Lamp : NH250 (25000 lm)+
With Globe and without Guard+
Reflector : FRP Dome Reflector+
10 81.0 60 145
15 87.8 65 148
20 97.9 70 148
25 111 75 148
30 115 80 125
35 115 85 81.0
40 122 90 33.8
45 128
Multipliers Coefficients of Utilization - Zonal Cavity
(For use with candlepower curves only)
%Effective Ceiling Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0LampWatts
ConversionFactor
Room Cavity Ratio/RCR 20% Effective Floor Cavity Reflectance
0 .92 .92 .92 .90 .90 .90 .86 .86 .86 .82 .82 .82 .79 .79 .79 .77
1 .79 .75 .72 .77 .73 .70 .74 .71 .68 .70 .68 .66 .68 .66 .64 .62
250 1 2 .67 .61 .56 .65 .60 .55 .62 .58 .54 .60 .56 .52 .57 .54 .51 .49
3 .57 .50 .44 .56 .49 .44 .54 .48 .43 .51 .46 .42 .49 .45 .42 .40
200 0.8 4 .50 .42 .36 .49 .42 .36 .47 .40 .36 .45 .39 .35 .43 .38 .34 .33
5 .44 .36 .30 .43 .36 .30 .41 .35 .30 .40 .34 .30 .38 .33 .29 .27
150 0.56 6 .39 .31 .26 .38 .31 .26 .37 .30 .26 .35 .30 .25 .34 .29 .25 .23
7 .35 .28 .23 .34 .27 .22 .33 .27 .22 .32 .26 .22 .31 .26 .22 .20
8 .32 .25 .20 .31 .25 .20 .30 .24 .20 .29 .24 .20 .28 .23 .19 .18
9 .29 .22 .18 .29 .22 .18 .28 .22 .18 .27 .21 .17 .26 .21 .17 .16
10 .27 .20 .16 .26 .20 .16 .26 .20 .16 .25 .19 .16 .24 .19 .16 .14
Angle cd/1000 lm Angle cd/1000 lm
<EVNHL 2175-DR> 0 91.6 50 149
5 91.6 55 143Lamp : MH175 (14000 lm)+
With Globe and without Guard+
Reflector : FRP Dome Reflector+
10 97.4 60 143
15 97.4 65 143
20 115 70 143
25 126 75 137
30 132 80 132
35 137 85 91.6
40 137 90 17.2
45 143
Multipliers Coefficients of Utilization - Zonal Cavity
(For use with candlepower curves only)
%Effective Ceiling Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%WallReflectance(ρw)
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0Lamp
Watts
Conversion
FactorRoom Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
250 1.47 0 .96 .96 .96 .94 .94 .94 .90 .90 .90 .86 .86 .86 .82 .82 .82 .81
1 .82 .78 .75 .80 .77 .74 .77 .74 .71 .74 .71 .69 .71 .69 .67 .65
175 1 2 .70 .64 .59 .69 .63 .58 .66 .61 .57 .63 .59 .55 .60 .57 .54 .52
3 .60 .53 .47 .59 .52 .47 .57 .51 .46 .54 .49 .45 .52 .48 .44 .42
4 .53 .45 .39 .52 .44 .39 .50 .43 .38 .48 .42 .38 .46 .41 .37 .35
5 .47 .39 .33 .46 .38 .33 .44 .37 .32 .42 .36 .32 .41 .36 .32 .30
6 .42 .34 .28 .41 .34 .28 .39 .33 .28 .38 .32 .28 .37 .31 .27 .26
7 .38 .30 .25 .37 .30 .25 .36 .29 .24 .34 .29 .24 .33 .28 .24 .22
8 .34 .27 .22 .34 .27 .22 .33 .26 .22 .32 .26 .22 .31 .25 .21 .20
9 .31 .24 .20 .31 .24 .20 .30 .24 .19 .29 .23 .19 .28 .23 .19 .18
10 .29 .22 .18 .28 .22 .18 .28 .22 .18 .27 .21 .18 .26 .21 .17 .16
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Compact Fluorescent Lighting Fixtures
EVN Series
Wet Locations
NEMA 3,3R,4,4X,7,9
Type of Explosion-proof Technical Data
Electrical RatingsNon Sparking (Ex nR II T4 IP66)
Dust Ignition-proof (Ex DP II 11 IP66)Rated Voltage AC110V/ 220V/ 240V
Rated Wattage 13W×3, 18W×3, 26W×3
< EVNCL 1263 >
Rated Frequency 50Hz/ 60Hz
Entry Sizes 1/2", 3/4", 1"
Weight
Mounting Type Catalog No. Weight
Pendant EVNCL 1263 9 Kg
Standard Materials
Housing, mounting modules,
component pallets : Fiber glass
reinforced polyester resin
Globe :
Heat resistant hard glass
Gasket : Silicone rubber
Reflector :
Fiber glass Reinforced Polyester
External Hardware :
Stainless steel, Brass
Application Features Certification
EVN Series lighting fixtures are used ;
in manufacturing plants, refineries,
chemical, petrochemical and other
industrial process facilities,
wastewater and sewage treatment
plants, offshore, dockside and other
harbor installations as well as other
heavy industrial applications.
wherever the damaging effects of
water, wind, snow, sleet, hot sun or
any combination of these elements
are found.
in withstands the harshest of
corrosive environments.
to provide low wattage spot and
floodlighting.
where an explosive atmosphere
consisting of a mixture with air of
flammable substances in the form
of gas, vapour or mist is not likely
to occur in normal operation but, if
it does occur, will persist for a
short period only.
where combustible dust, moisture,
dirt are present and vibration,
corrosion, rough usage are
problems.
Enclosure in glass fiber reinforced
polyester resin, provide excellent
resistant to corrosion so have a
long life.
Enclosure contain ultraviolet
interception ingredient to resist
transformation.
Easy installation and maintenance
Internal type ballast.
Pendant mounting module
equipped with integral hub set
screws for vibration resistance.
Guard, hub inserts, stanchion
elbow and hardware made of
stainless steel for maximum
resistance to corrosion.
Grounding wire for safety.
Hinged assembly allows the
fixture to hang free during
installation to permit the use of
both hands when wiring.
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Compliance
IEC 60079-0, 15
NEMA 3, 3R, 4, 4X
Standard Finish
Dark Gray
If you want another color,
contact us please.
Options
With Dome Reflector or 30°
Angle Reflector with SMC or
High Grade Aluminium
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt Hub Size Pendant Ceiling Bracket Stanchion Certification
Compact
Fluorescent
13W×31/2" EVNCL 1135 EVNCL 2135 EVNCL 3135 EVNCL 9135
Ex nR II T4
Ex DP II 12
3/4" EVNCL 1133 EVNCL 2133 EVNCL 3133 EVNCL 9133
18W×31/2" EVNCL 1185 EVNCL 2185 EVNCL 3185 EVNCL 9185
3/4" EVNCL 1183 EVNCL 2183 EVNCL 3183 EVNCL 9183
26W×31/2" EVNCL 1265 EVNCL 2265 EVNCL 3265 EVNCL 9265
3/4" EVNCL 1263 EVNCL 2263 EVNCL 3263 EVNCL 9263
Ordering Information EVN Lighting Fixture①
E VN C L 1 1 3 5 - DR Lamp Type②
① ② ③ ④ ⑤ ⑥ CL - Compact Fluorescent
Mounting Type③ Lamp Wattage (W)④ Entry Size⑤ Options⑥
1 - Pendant 13 - 13W×3 1 - 1" DR - Dome Reflector with SMC
2 - Ceiling 18 - 18W×3 3 - 3/4" AR - Angle Reflector with SMC
3 - Bracket 26 - 26W×3 5 - 1/2" C※ an order Aluminium Reflector instead of FRP
Reflector 9 - Stanchion
▞ Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<EVNCL 2265-DR> 0 86.0 50 111
5 86.0 55 111Lamp : CFL26+ ×3 (5400 lm)
With Globe and without Guard+
Reflector : FRP Dome Reflector+
10 86.0 60 109
15 87.5 65 106
20 90.6 70 96.9
25 93.7 75 82.9
30 98.4 80 64.1
35 103 85 43.7
40 106 90 25.0
45 109
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall
Reflectance(ρw)50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio
RCR20% Effective Floor Cavity Reflectance
0 .67 .67 .67 .66 .66 .66 .63 .63 .63 .60 .60 .60 .58 .58 .58 .57
1 .58 .56 .53 .57 .55 .53 .55 .53 .51 .52 .51 .49 .50 .49 .48 .47
2 .50 .46 .43 .49 .45 .42 .47 .44 .41 .45 .43 .40 .44 .41 .39 .38
3 .44 .39 .35 .43 .38 .35 .41 .37 .34 .40 .36 .33 .38 .35 .33 .32
4 .38 .33 .29 .38 .33 .29 .36 .32 .29 .35 .31 .28 .34 .30 .28 .27
5 .34 .29 .25 .34 .28 .25 .32 .28 .24 .31 .27 .24 .30 .27 .24 .23
6 .31 .25 .22 .30 .25 .21 .29 .25 .21 .28 .24 .21 .27 .24 .21 .20
7 .28 .23 .19 .27 .22 .19 .26 .22 .19 .25 .21 .19 .25 .21 .18 .17
8 .25 .20 .17 .25 .20 .17 .24 .20 .17 .23 .19 .17 .23 .19 .16 .15
9 .23 .18 .15 .23 .18 .15 .22 .18 .15 .21 .18 .15 .21 .17 .15 .14
10 .21 .17 .14 .21 .17 .14 .20 .16 .14 .20 .16 .14 .19 .16 .13 .12
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< EVN Bracket Type > < EVN Stanchion Type >
< EVN Pendant Type > < EVN Ceiling Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
EU Series
Wet Locations
Factory Sealed
NEMA 3, 3R, 7
Type of Explosion-proof
Flameproof (Ex d IIB T4)
Dust Ignition-proof (Ex DP II 12)
< EU >
Application Features EU Series lighting fixtures are used;
in tunnels, building entrances
and similar locations where
moisture, dirt, chemicals or
rough usage are a problem.
in heavy process industries
having environments where
flammable or explosive vapors or
gases, or where combustible
dusts are present.
in areas where combustible dusts
and flammable vapors are
present simultaneously.
in hazardous areas, both indoors
and outdoors where long life
and low maintenance costs are
desired.
where high light output is
needed but space is limited.
where ignitable concentrations of
flammable gases, vapors, liquids
or dusts can exist some of the
time under normal operating
conditions.
Lighting unit and ballast are
constructed separately so as to
protect the ballast from the heat
of the lamp.
Lighting unit is screwed onto the
top of the mounting box and the
ballast to the side.
Globe assembly is securely
hinged to the body.
Ballast is a high quality one
maintaining much safety on
strength of enclosure,
weatherproof and temperature
rise.
Mounting box has four-way
conduit entries and a large
access cover for wiring.
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Standard Materials Certification Compliance
Enclosure : Die casting aluminium
Globe : Heat resistant hard glass
Inner Reflector : High purity
aluminium
External Hardware : Stainless steel
Mounting Box : Cast aluminium alloy
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas
Safety Corporation), and the
others.
IEC 60079-0, 1
NEMA 3, 3R, 7
IP 55
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated Voltage AC110V/ 220V/ 240V ( See Below)※ Ceiling EUNL 32210 8.6 ㎏
Rated Wattage 50W/ 70W/ 100W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
Also you can order various voltage : ※
120V/ 208V/ 277V/ 460V
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt Volts Pendant Ceiling90°
Bracket
40°
BracketCertification
High Pressure Sodium
50100-120 EUNL 31105 EUNL 32105 EUNL 33105 EUNL 34105
Ex d IIB T3
200-220 EUNL 31205 EUNL 32205 EUNL 33205 EUNL 34205
70100-120 EUNL 31107 EUNL 32107 EUNL 33107 EUNL 34107
200-220 EUNL 31207 EUNL 32207 EUNL 33207 EUNL 34207
100100-120 EUNL 31110 EUNL 32110 EUNL 33110 EUNL 34110
200-220 EUNL 31210 EUNL 32210 EUNL 33210 EUNL 34210
Metal Halide 100100-120 EUHL 31110 EUHL 32110 EUHL 33110 EUHL 34110
Ex d IIB T4200-220 EUHL 31210 EUHL 32210 EUHL 33210 EUHL 34210
Mercury Vapor 100100-120 EUML 31110 EUML 32110 EUML 33110 EUML 34110
200-220 EUML 31210 EUML 32210 EUML 33210 EUML 34210
* For Pole type, see pole section (2L-51)
Ordering Information Temperature Performance Data
E U N L 3 2 1 1 0 Lamp Ambient Flameproof Dust-Ignition
① ② ③ ④ ⑤ ⑥ Type Watt. Temp ( )℃ "d" "DP"
EU Lighting Fixture① Mounting Type④
H.I.D
5040 T4 12
1 - Pendant 55 - -
Lamp Type② 2 - Ceiling70
40 T4 12
NL - H.P.Sodium 3 - 90° Bracket 55 - -
HL - Metal Halide 4 - 40° Bracket 100
40 T4 12
ML - Mercury Vapor 55 - -
Voltage (V)⑤
Type of Lighting Fixture③ 1 - 100-120
3 - EUL Type 2 - 200-220
Wattage (W)⑥
05 - 50, 07 - 70, 10 - 100
Dimension
<Ceiling Type> <Pendant Type> <90° Bracket Type > <40° Bracket Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle /1000㏅ ㏐ Angle /1000㏅ ㏐
<EUNL 32110> 0 93.7 50 107
5 76.8 55 112Lamp : NH100 (9000 lm)+
With Guard+ 10 77.8 60 116
15 81.5 65 125
20 76.8 70 131
25 77.8 75 132
30 81.5 80 133
35 87.2 85 139
40 91.9 90 143
45 99.4
Coefficients of Utilization - Zonal Cavity
Multipliers%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
(For use with
candlepower
curves only)
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Lamp
Watts
Conversion
Factor
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .85 .85 .85 .83 .83 .83 .79 .79 .79 .76 .76 .76 .73 .73 .73 .71
1 .71 .67 .63 .69 .66 .62 .66 .63 .60 .63 .61 .59 .61 .59 .57 .55
100 1 2 .59 .53 .48 .58 .52 .47 .55 .50 .46 .52 .48 .45 .50 .47 .44 .42
3 .50 .43 .37 .49 .42 .37 .46 .41 .36 .44 .39 .35 .42 .38 .34 .33
70 0.5 4 .43 .36 .30 .42 .35 .30 .40 .34 .29 .38 .33 .29 .37 .32 .28 .26
5 .38 .30 .25 .37 .30 .25 .35 .29 .24 .34 .28 .24 .32 .27 .24 .22
50 0.25 6 .34 .26 .21 .33 .26 .21 .31 .25 .21 .30 .25 .20 .29 .24 .20 .19
7 .30 .23 .18 .30 .23 .18 .28 .22 .18 .27 .22 .18 .26 .21 .18 .16
8 .27 .21 .16 .27 .20 .16 .26 .20 .16 .25 .20 .16 .24 .19 .16 .14
9 .25 .19 .14 .25 .18 .14 .24 .18 .14 .23 .18 .14 .22 .17 .14 .12
10 .23 .17 .13 .23 .17 .13 .22 .16 .13 .21 .16 .13 .21 .16 .13 .11
Angle /1000㏅ ㏐ Angle /1000㏅ ㏐
<EUHL 32110> 0 123 50 98.7
5 112 55 104Lamp : MH100 (6500 lm)+
With Guard+ 10 114 60 109
15 117 65 149
20 116 70 147
25 135 75 148
30 140 80 144
35 121 85 134
40 101 90 106
45 97.3
Coefficients of Utilization - Zonal Cavity%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .95 .95 .95 .93 .93 .93 .89 .89 .89 .85 .85 .85 .82 .82 .82 .80
1 .80 .76 .72 .78 .74 .71 .75 .72 .69 .72 .69 .67 .69 .67 .65 .63
2 .67 .61 .55 .66 .60 .54 .63 .58 .53 .60 .56 .52 .57 .54 .51 .49
3 .57 .50 .44 .56 .49 .43 .54 .47 .42 .51 .46 .41 .49 .45 .41 .39
4 .50 .42 .36 .49 .41 .35 .47 .40 .35 .45 .39 .34 .43 .38 .34 .32
5 .44 .36 .30 .43 .36 .30 .41 .35 .29 .40 .34 .29 .38 .33 .29 .27
6 .40 .32 .26 .39 .31 .26 .37 .30 .25 .36 .30 .25 .34 .29 .25 .23
7 .36 .28 .23 .35 .28 .23 .34 .27 .22 .33 .27 .22 .31 .26 .22 .20
8 .33 .25 .20 .32 .25 .20 .31 .25 .20 .30 .24 .20 .29 .24 .20 .18
9 .30 .23 .18 .30 .23 .18 .29 .22 .18 .28 .22 .18 .27 .22 .18 .16
10 .28 .21 .17 .27 .21 .17 .27 .21 .17 .26 .20 .16 .25 .20 .16 .15
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
EA Series
Wet Locations
Factory Sealed
NEMA 3, 3R, 7
< EA >
Type of Explosion-proof
Flameproof (Ex d IIB T4 H2)
Flameproof (Ex d IIC T4 H2)
Standard Materials
Enclosure : Die casting aluminium alloy
Globe : Heat resistant hard glass
Inner Reflector : High purity aluminium
Guard : Stainless steel
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Application Features Globe assembly is securely hinged
to the body.
Easy installation and maintenance.
Hinged assembly allows the fixture
to hang free during installation to
permit the use of both hands
when wiring.
Can use compact fluorescent lamp
45W instead of HID lamp without
external ballast.
EA Series lighting fixture are used ;in heavy process industries having environments where flammable or explosive vapors or gases, or where combustible dusts are present.in paint spray booth suitability provides efficient, economical HID lighting for paint spray areas.in hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired. in hazardous locations requiring elevated ambient capability.in marine applications where water spray and corrosive atmospheres are considerations.
Lighting unit and ballast are constructed separately so as to protect the ballast from the heat of the lamp.Base of the body and the top of the globe holder have accurate tapered cylindrical surfaces and are secured by four socket head captive screw.Lighting unit is screwed onto the top of the mounting box and the ballast to the side.Pendant mounting module equipped with integral hub set screws for vibration resistance.Globe assembly is securely hinged to the body.
Compliance & Certification
IEC 60079-0, 1 NEMA 3, 3R, 7IP 55Certified by KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others.
Technical Data Lamp Replacement
Electrical Rating
Rated Voltage AC110V/ 220V/ 240V ( See Below)※
Rated Wattage 100W/ 150W/ 175W/ 200W/ 250W/ 400W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
Also you can order various voltage : ※
110V/ 120V/ 208V/ 220V/ 240V/ 277V/ 460V
Weight
Mounting Type Catalog No. Weight
Small (Ceiling) EANL 2215 17.3 ㎏
Large (Ceiling) EAML 2240 28.3 ㎏
If you need more information, contact us please.☞
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt Pendant Ceiling 90° Bracket 40° Bracket Certification
High
Pressure
Sodium
150 EANL 2115 EANL 2215 EANL 2315 EANL 2415
Ex d IIC T4200 EANL 2120 EANL 2220 EANL 2320 EANL 2420
250 EANL 2125 EANL 2225 EANL 2325 EANL 2425
400 EANL 2140 EANL 2240 EANL 2340 EANL 2440 Ex d IIB T3
Metal
Halide
175 EAHL 2117 EAHL 2217 EAHL 2317 EAHL 2417Ex d IIC T4
250 EAHL 2125 EAHL 2225 EAHL 2325 EAHL 2425
400 EAHL 2140 EAHL 2240 EAHL 2340 EAHL 2440 Ex d IIB T3
Mercury
Vapor
200 EAML 2120 EAML 2220 EAML 2320 EAML 2420Ex d IIC T4
250 EAML 2125 EAML 2225 EAML 2325 EAML 2425
400 EAML 2140 EAML 2240 EAML 2340 EAML 2440 Ex d IIB T3
Dimension Ordering Information
<Ceiling Type>
<Pendant Type>
<40°Bracket Type>
<90°Bracket Type>
E A N L 2 1 1 5 ① ② ③ ④ ⑤
EA Lighting Fixture① Mounting Type④
1 - Pendant
2 - Ceiling
Lamp Type② 3 - 90° Bracket
NL - High Pressure Sodium 4 - 40° Bracket
HL - Metal Halide
ML - Mercury Vapour ⑤ Lamp Wattage(w)
15 - 150
17 - 175
Model Type③ 20 - 200
2 - EA Type 25 - 250
40 - 400
Temperature Performance Data
Lamp Ambient Flame
Type Watt. Temp ( )℃ Proof "d"
High
Pressure
Sodium
15040 T4
55 T4
20040 T4
55 T4
25040 T4
55 T4
40040 T3
55 T3
Metal
Halide
17540 T4
55 T4
25040 T4
55 T4
40040 T3
55 T3
Mercury
Vapor
20040 T4
55 T4
25040 T4
55 T4
40040 T3
55 T3
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
0 122 50 161<EAHL 2225>5 108 55 171
Lamp : MH250 (20500 lm)+
With Globe and without Guard+10 94.4 60 164
15 105 65 126
20 143 70 115
25 170 75 112
30 147 80 80.4
35 133 85 38.4
40 129 90 17.4
45 133
Coefficients of Utilization - Zonal Cavity
Multipliers(For use with candlepower curves only)
%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall
Reflectance(ρw)50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Lamp
Watts
Conversion
Factor
Room Cavity Ratio
RCR20% Effective Floor Cavity Reflectance
0 .89 .89 .89 .87 .87 .87 .83 .83 .83 .79 .79 .79 .76 .76 .76 .74
1 .77 .74 .71 .76 .73 .70 .72 .70 .68 .70 .68 .66 .67 .65 .64 .62
250 1 2 .67 .62 .58 .66 .61 .57 .63 .59 .56 .61 .57 .54 .58 .56 .53 .52
3 .59 .53 .48 .58 .52 .47 .55 .50 .46 .53 .49 .46 .51 .48 .45 .43
175 0.68 4 .52 .45 .40 .51 .45 .40 .49 .44 .39 .47 .42 .39 .46 .41 .38 .36
5 .46 .39 .34 .45 .39 .34 .44 .38 .34 .42 .37 .33 .41 .36 .33 .31
6 .41 .35 .30 .41 .34 .30 .39 .34 .29 .38 .33 .29 .37 .32 .29 .27
7 .38 .31 .26 .37 .31 .26 .36 .30 .26 .35 .30 .26 .34 .29 .26 .24
8 .34 .28 .23 .34 .28 .23 .33 .27 .23 .32 .27 .23 .31 .26 .23 .21
9 .31 .25 .21 .31 .25 .21 .30 .25 .21 .29 .24 .21 .29 .24 .21 .19
10 .29 .23 .19 .29 .23 .19 .28 .23 .19 .27 .22 .19 .27 .22 .19 .17
Angle cd/1000 lm Angle cd/1000 lm
0 172 50 118<EANL 2225>
5 135 55 125Lamp : NH250 (25000 lm)+
With Globe and without Guard+ 10 94.5 60 125
15 105 65 125
20 142 70 108
25 182 75 87.8
30 142 80 67.5
35 108 85 50.6
40 97.9 90 30.4
45 101
Coefficients of Utilization - Zonal Cavity
Multipliers(For use with
candlepower
curves only)
%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall
Reflectance(ρw)50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Lamp
Watts
Conversion
Factor
Room Cavity Ratio
RCR20% Effective Floor Cavity Reflectance
0 .89 .89 .89 .87 .87 .87 .83 .83 .83 .79 .79 .79 .76 .76 .76 .74
1 .77 .74 .71 .76 .73 .70 .72 .70 .68 .70 .68 .66 .67 .65 .64 .62
250 1 2 .67 .62 .58 .66 .61 .57 .63 .59 .56 .61 .57 .54 .58 .56 .53 .52
3 .59 .53 .48 .58 .52 .47 .55 .50 .46 .53 .49 .46 .51 .48 .45 .43
200 0.8 4 .52 .45 .40 .51 .45 .40 .49 .44 .39 .47 .42 .39 .46 .41 .38 .36
5 .46 .39 .34 .45 .39 .34 .44 .38 .34 .42 .37 .33 .41 .36 .33 .31
150 0.56 6 .41 .35 .30 .41 .34 .30 .39 .34 .29 .38 .33 .29 .37 .32 .29 .27
7 .38 .31 .26 .37 .31 .26 .36 .30 .26 .35 .30 .26 .34 .29 .26 .24
8 .34 .28 .23 .34 .28 .23 .33 .27 .23 .32 .27 .23 .31 .26 .23 .21
9 .31 .25 .21 .31 .25 .21 .30 .25 .21 .29 .24 .21 .29 .24 .21 .19
10 .29 .23 .19 .29 .23 .19 .28 .23 .19 .27 .22 .19 .27 .22 .19 .17
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Compact Fluorescent Lighting Fixtures
EA Series
Wet Locations
Factory Sealed
NEMA 3, 3R, 7
< EACL >
Type of Explosion-proof
Flameproof (Ex d IIC T6)
Standard Materials
Enclosure : Die casting aluminium alloy
Globe : Heat resistant hard glass
Inner Reflector : High purity aluminium
Guard : Stainless steel
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Application Features
Compliance & CertificationEA Series lighting fixtures are used ;
in heavy process industries
having environments where
flammable or explosive vapors
or gases, or where combustible
dusts are present
in paint spray booth suitability
provides efficient, economical
HID lighting for paint spray
areas
in hazardous areas, both
indoors and outdoors where
long life and low maintenance
costs are desired
in hazardous locations requiring
elevated ambient capability
in marine applications where
water spray and corrosive
atmospheres are considerations
Base of the body and the top of
the globe holder have accurate
tapered cylindrical surfaces and
are secured by four socket head
captive screw
Globe assembly is securely
hinged to the body
Lighting unit is screwed onto the
top of the mounting box
Easy installation and
maintenance
Pendant mounting module
equipped with integral hub set
screws for vibration resistance.
Hinged assembly allows the
fixture to hang free during
installation to permit the use of
both hands when wiring.
Can use HID lamps instead of
compact fluorescent lamp with
external ballast.
IEC 60079-0, 1
NEMA 3, 3R, 7
IP 55
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS(Korea Gas Safety
Corporation), and the others.
Technical Data
Electrical Rating
Rated Voltage AC110V/ 220V/ 240V
Rated Wattage Compact Fluorescent 45W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
Weight
Mounting Type Catalog No. Weight
Ceiling EACL 2204 9.5 ㎏
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension Ordering Number
<Ceiling Type>
<Pendant Type>
<40°Bracket Type>
<90°Bracket Type>
Lamp Compact Fluorescent
Watt 45 55
Mounting
Type
Pendant EACL 2104 EACL 2105
Ceiling EACL 2204 EACL 2205
90° Bracket EACL 2304 EACL 2305
40° Bracket EACL 2404 EACL 2405
Certification Ex d IIC T6
Ordering Information
E A C L 2 1 0 4 ① ② ③ ④ ⑤
EA Lighting Fixture① Mounting④
1 - Pendant
2 - Ceiling
Lamp Type② 3 - 90° Bracket
CL - Compact Fluorescent 4 - 40° Bracket
Model Type③ Lamp Wattage⑤
2 - EA Type 04 - 45
Temperature Performance Data
Lamp Ambient Flame
Type Watt. Temp ( )℃ Proof "d"
Compact
Fluorescent
4540 85 (T6)
55 -
5540 85 (T6)
55 -
7040 85 (T6)
55 -
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<EACL 2104> 0 101 50 95.8
5 101 55 95.8Lamp : CFL45W (3000 lm)+
With Globe and without Guard+ 10 98.6 60 93.2
15 85.1 65 87.6
20 93.2 70 78.3
25 112 75 72.9
30 112 80 56.7
35 101 85 47.3
40 95.8 90 39.2
45 98.6
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall
Reflectance(ρw)50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio
RCR20% Effective Floor Cavity Reflectance
0 .63 .63 .63 .61 .61 .61 .59 .59 .59 .56 .56 .56 .54 .54 .54 .53
1 .54 .52 .50 .53 .51 .49 .51 .49 .47 .49 .47 .46 .47 .46 .44 .43
2 .47 .43 .40 .46 .42 .39 .44 .41 .38 .42 .40 .38 .41 .39 .37 .35
3 .41 .36 .33 .40 .36 .32 .38 .35 .32 .37 .34 .31 .36 .33 .31 .30
4 .36 .31 .28 .35 .31 .27 .34 .30 .27 .33 .29 .27 .32 .29 .26 .25
5 .32 .27 .24 .32 .27 .24 .30 .26 .23 .29 .26 .23 .28 .25 .23 .22
6 .29 .24 .21 .29 .24 .21 .28 .23 .20 .27 .23 .20 .26 .23 .20 .19
7 .26 .22 .18 .26 .21 .18 .25 .21 .18 .24 .21 .18 .24 .20 .18 .17
8 .24 .20 .16 .24 .19 .16 .23 .19 .16 .22 .19 .16 .22 .18 .16 .15
9 .22 .18 .15 .22 .18 .15 .21 .17 .15 .21 .17 .15 .20 .17 .15 .14
10 .21 .16 .14 .20 .16 .14 .20 .16 .13 .19 .16 .13 .19 .16 .13 .12
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
EVS Series
Wet Locations
NEMA 3, 3R, 7
Type of Explosion-proof
Flameproof-Increase Safety
(Ex de IIC T3 IP66)
Application Features
EVS Series HID lighting fixture are used ;
in Heavy process industries having environments
where flammable or explosive vapors or gases, or
where combustible dusts are present.
in Hazardous areas, both indoors and outdoors
where long life and low maintenance costs are
desired.
in Petroleum refineries, chemical, petrochemical
and other heavy process industry facilities.
in Paint spray booth suitability provides efficient,
economical HID lighting for paint spray areas.
in Hazardous locations requiring elevated ambient
capability.
in installations where moisture, dirt, dust, vibration,
corrosion and rough usage are problems.
where ignitable concentrations of flammable gases,
vapors or liquids can exist all of the time or some
of the time under normal operation conditions.
Fixture is factory wired; power is fed through "wireless"
connection block which serves as a mechanical seal
between conduit and ballast compartments, eliminating
the need for a field installed seal. The result is fast,
easy installation, lowest installed cost, easy
maintenance.
Dome and 30°angle reflectors made of SMC material
won't rust, corrode, dent, chip or peel.
Four mounting arrangements to suit any lighting
layout-pendant, ceiling, wall bracket and stanchion.
Internal ballasts-separate ballasts are not required. High
power factor (90%) ballasts reduce power costs-allow
more fixtures per circuit.
Factory sealed, porcelain with mogul or medium base
socket.
Wide range of light sources to meet specific lighting
needs - High Pressure Sodium (HPS): 50, 70, 100,
150, 200, 250 and 400W, Mercury Vapour (MV): 100,
200, 250 and 400W, Metal Halide (MH): 100, 175, 250
and 400W.
Standard Materials Compliance
Enclosure : Die casting
aluminium
Globe : Heat resistant hard glass
Lamp socket : Porcelain with
screw shell
Reflector : Fiberglass Reinforced
Polyester
External Hardware : Stainless
steel
IEC 60079-0, 1, 7
NEMA 3, 3R, 7
Certification
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS(Korea Gas Safety
Corporation), and the others.
Options Standard Finish With Dome Reflector or 30°
Angle Reflector made of FRP
With Choke or Lead Peak type
Ballast.
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
< EVS >
Technical Data
Electrical Rating
Rated Voltage AC110V/ 220V/ 240V ( See Below) ※
Rated Wattage50W/ 70W/ 100W/ 150W/
175W/ 200W/ 250W/ 400W Weight
Rated Frequency 50Hz/ 60Hz Catalog No. Weight
Entry Size 1/2", 3/4", 1" EVSHL 3255 16.9 ㎏
Also you can order various voltage : ※
120V/ 208V/ 277V/ 460V
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp WattHub
SizePendant Ceiling Bracket Stanchion Certification
High
Pressure
Sodium
501/2" EVSNL 1055 EVSNL 2055 EVSNL 3055 EVSNL 4055
Ex de IIC T3
3/4" EVSNL 1053 EVSNL 2053 EVSNL 3053 EVSNL 4053
701/2" EVSNL 1075 EVSNL 2075 EVSNL 3075 EVSNL 4075
3/4" EVSNL 1073 EVSNL 2073 EVSNL 3073 EVSNL 4073
1001/2" EVSNL 1105 EVSNL 2105 EVSNL 3105 EVSNL 4105
3/4" EVSNL 1103 EVSNL 2103 EVSNL 3103 EVSNL 4103
1501/2" EVSNL 1155 EVSNL 2155 EVSNL 3155 EVSNL 4155
3/4" EVSNL 1153 EVSNL 2153 EVSNL 3153 EVSNL 4153
2001/2" EVSNL 1205 EVSNL 2205 EVSNL 3205 EVSNL 4205
3/4" EVSNL 1203 EVSNL 2203 EVSNL 3203 EVSNL 4203
2501/2" EVSNL 1255 EVSNL 2255 EVSNL 3255 EVSNL 4255
3/4" EVSNL 1253 EVSNL 2253 EVSNL 3253 EVSNL 4253
4001/2" EVSNL 1405 EVSNL 2405 EVSNL 3405 EVSNL 4405
3/4" EVSNL 1403 EVSNL 2403 EVSNL 3403 EVSNL 4403
Metal
Halide
1001/2" EVSHL 1105 EVSHL 2105 EVSHL 3105 EVSHL 4105
3/4" EVSHL 1103 EVSHL 2103 EVSHL 3103 EVSHL 4103
1751/2" EVSHL 1175 EVSHL 2175 EVSHL 3175 EVSHL 4175
3/4" EVSHL 1173 EVSHL 2173 EVSHL 3173 EVSHL 4173
2501/2" EVSHL 1255 EVSHL 2255 EVSHL 3255 EVSHL 4255
3/4" EVSHL 1253 EVSHL 2253 EVSHL 3253 EVSHL 4253
4001/2" EVSNL 1405 EVSNL 2405 EVSNL 3405 EVSNL 4405
Ex de IIC T23/4" EVSNL 1403 EVSNL 2403 EVSNL 3403 EVSNL 4403
Mercury
Vapor
1001/2" EVSML 1105 EVSML 2105 EVSML 3105 EVSML 4105
Ex de IIC T3
3/4" EVSML 1103 EVSML 2103 EVSML 3103 EVSML 4103
2001/2" EVSML 1205 EVSML 2205 EVSML 3205 EVSML 4205
3/4" EVSML 1203 EVSML 2203 EVSML 3203 EVSML 4203
2501/2" EVSML 1255 EVSML 2255 EVSML 3255 EVSML 4255
3/4" EVSML 1253 EVSML 2253 EVSML 3253 EVSML 4253
4001/2" EVSML 1405 EVSML 2405 EVSML 3405 EVSML 4405
3/4" EVSML 1403 EVSML 2403 EVSML 3403 EVSML 4403
Ordering Information
E V S N L 1 0 7 5 - DR ① ② ③ ④ ⑤ ⑥
EVS Lighting Fixture① Lamp Type② Mounting Type③ Lamp Wattage (W)④
NL - High Pressure Sodium 1 - Pendant 05 - 50
HL- Metal Halide 2 - Ceiling 07 - 70
ML - Mercury Vapour 3 - Bracket 10 - 100
4 - Stanchion 15 - 150
Entry Size⑤ Options⑥ 17 - 175
1 - 1" DR - Dome Type Reflector 20 - 200
3 - 3/4" AR - Angle Type Reflector 25 - 250
5 - 1/2" 40 - 400
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
0 132.6 50 116.5
5 126.8 55 116.1<EVSHL17C1-SD>10 124.6 60 121.4
Lamp : MH175 (14000 lm)+
With Guard+15 123.7 65 131.7
20 118.3 70 129.5
25 116.1 75 83.0
30 118.8 80 33.0
35 113.8 85 20.5
40 107.1 90 8.5
45 109.4
Dimension
< EVS Ceiling Type> < EVS Pendant Type>
< EVS Bracket Type > < EVS Stanchion Type >
A B C D E
100W Ø255 455 445 470 480
250W Ø270 520 510 535 545
400W Ø270 565 555 580 590
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
EG Series
Wet Locations
Marine Locations
NEMA 3,3R,4,4X,7
Type of Explosion-proof
<EG>
Class I Division 1 Group C,D
Flameproof (Ex d IIC T4 IP66)
Dust Ignition-proof (Ex DP II 12)
Application
EG Series HID lighting fixtures are used ;
in heavy process industries having environments where flammable or
explosive vapors or gases, or where combustible dusts are present.
in hazardous areas, both indoors and outdoors where long life and low
maintenance costs are desired.
in petroleum refineries, chemical, petrochemical and other heavy process
industry facilities.
in paint spray booth suitability provides efficient, economical HID lighting
for paint spray areas.
where ignitable concentrations of flammable gases, vapors or liquids can
exist all of the time or some of the time under normal operation
conditions.
in hazardous locations requiring elevated ambient capability.
in installations where moisture, dirt, dust, vibration, corrosion and rough
usage are problems.
Fixture Wattage
<EGS>
Lamp EG Series Wattage
Type EGS EG
HPS 50, 70, 100 150, 200, 250, 400
MH 100 175, 250, 400
MV 100 200, 250, 400
Features
Fixture is factory wired; power is fed through "wireless" connection block
which serves as a mechanical seal between conduit and ballast
compartments, eliminating the need for a field installed seal. The result is
fast, easy installation, lowest installation cost, easy maintenance.
Dome and 30°angle reflectors made of SMC material won't rust, corrode,
dent, chip or peel.
Internal ballasts-separate ballasts are not required. High power factor (90%)
ballasts reduce power costs-allow more fixtures per circuit.
Factory sealed, porcelain with mogul or medium base socket.
Wide range of light sources to meet specific lighting needs - High Pressure
Sodium (HPS): 50, 70, 100, 150, 200, 250 and 400W, Mercury Vapour (MV):
100, 200, 250 and 400W, Metal Halide (MH): 100, 175, 250 and 400W.
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
EGS Series
Wet Locations
Marine Locations
NEMA 3,3R,4,4X,7
<EGS>
Type of Explosion-proof
Flameproof (Ex d IIC T4 IP66)
Features
Compact, lightweight design is ideal for
medium and low mounting heights.
Dome and 30°angle reflectors made of SMC
material won't rust, corrode, dent, chip or
peel.
Wide range of light sources to meet specific
lighting needs - 50, 70 and 100W High
Pressure Sodium (HPS); 100W Mercury Vapour
(MV) and Metal Halide (MH).
Standard Materials
Enclosure : Die casting aluminium
Globe : Heat resistant hard glass
Lamp socket : Porcelain with screw shell
Reflector : Fiber glass Reinforced polyester
Guard : Die casting aluminium
Technical Data
Electrical Rating
Rated Voltage AC110V/ 220V/ 240V ( See Below)※
Rated Wattage 50W/ 70W/ 100W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"Standard Finish
Also you can order various voltage : ※
120V/ 208V/ 277V/ 460VMUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
WeightCompliance & CertificationMounting Type Catalog No. WeightIEC 60079-0, 1
NEMA 3, 3R, 4, 4X, 7
Certified by KOSHA (Korea Occupational
Safety & Health Agency), KGS (Korea Gas
Safety Corporation), and the others.
Ceiling EGSNL 2101 11.4 ㎏
Option
With Dome Reflector or 30° Angle Reflector
made of FRP
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp WattHub
SizePendant Ceiling Bracket Stanchion Certification
High
Pressure
Sodium
501" EGSNL 1051 EGSNL 2051 EGSNL 3051 EGSNL 4051
Ex d IIC T4 IP66
3/4" EGSNL 1053 EGSNL 2053 EGSNL 3053 EGSNL 4053
1/2" EGSNL 1055 EGSNL 2055 EGSNL 3055 EGSNL 4055
701" EGSNL 1071 EGSNL 2071 EGSNL 3071 EGSNL 4071
3/4" EGSNL 1073 EGSNL 2073 EGSNL 3073 EGSNL 4073
1/2" EGSNL 1075 EGSNL 2075 EGSNL 3075 EGSNL 4075
1001" EGSNL 1101 EGSNL 2101 EGSNL 3101 EGSNL 4101
3/4" EGSNL 1103 EGSNL 2103 EGSNL 3103 EGSNL 4103
1/2" EGSNL 1105 EGSNL 2105 EGSNL 3105 EGSNL 4105
Metal
Halide100
1" EGSHL 1101 EGSHL 2101 EGSHL 3101 EGSHL 4101
3/4" EGSHL 1103 EGSHL 2103 EGSHL 3103 EGSHL 4103
1/2" EGSHL 1105 EGSHL 2105 EGSHL 3105 EGSHL 4105
Mercury
Vapor100
1" EGSML 1101 EGSML 2101 EGSML 3101 EGSML 4101
3/4" EGSML 1103 EGSML 2103 EGSML 3103 EGSML 4103
1/2" EGSML 1105 EGSML 2105 EGSML 3105 EGSML 4105
Ordering Information Temperature Performance Data
E G S N L 1 1 0 1 / 4 - DR Lamp AmbientFlameproof "d"
① ② ③ ④ ⑤ ⑥ ⑦ Type Watt Temp ( )℃
High
Pressure
Sodium
5040 T4
EGS Lighting Fixture① Entry Size⑤ 55 T4
1 - 1"70
40 T4
Lamp Type② 3 - 3/4" 55 T4
NL - High Pressure Sodium 5 - 1/2"100
40 T4
HL - Metal Halide 55 T4
ML - Mercury Vapour Input Voltage (V)⑥ Metal
Halide100
40 T4
1 - 110 55 T4
Mounting Type③ 2 - 120 Mercury
Vapor100
40 T4
1 - Pendant 3 - 208 55 T4
2 - Ceiling 4 - 220
3 - Bracket 5 - 240
4 - Stanchion 6 - 277
7 - 460
Lamp Wattage (W)④
05 - 50 Options⑦
07 - 70 DR - Dome Type Reflector
10 - 100 AR - Angle Type Reflector
Dimension
< EGS Bracket Type > < EGS Stanchion Type > < EGS Ceiling Type > < EGS Pendant Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<EGSNL 1101/4 - DR> 0 233 50 194
5 216 55 180Lamp : NH100 (9000 lm)+
With Globe +
Reflector : +
FRP Dome Reflector
10 212 60 163
15 193 65 132
20 194 70 67.5
25 195 75 32.8
30 198 80 21.6
35 200 85 10.3
40 201 90 5.7
45 202
Coefficients of Utilization - Zonal Cavity
Multipliers%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
(For use with
candlepower
curves only)
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
Lamp
Watts
Conversion
Factor0 .94 .94 .94 .91 .91 .91 .87 .87 .87 .84 .84 .84 .80 .80 .80 .79
1 .83 .80 .78 .82 .79 .76 .78 .76 .74 .75 .73 .72 .72 .71 .70 .68
100 1 2 .75 .70 .66 .73 .69 .65 .70 .67 .67 .68 .65 .62 .66 .63 .61 .59
3 .67 .61 .57 .66 .60 .56 .63 .59 .55 .61 .58 .54 .59 .56 .53 .52
70 0.5 4 .60 .54 .49 .59 .53 .49 .57 .52 .48 .55 .51 .48 .54 .50 .47 .46
5 .54 .48 .43 .53 .48 .43 .52 .47 .43 .50 .46 .42 .49 .45 .42 .40
50 0.25 6 .49 .43 .38 .49 .43 .38 .47 .42 .38 .46 .41 .38 .45 .41 .37 .36
7 .45 .39 .34 .45 .39 .34 .43 .38 .34 .42 .37 .34 .41 .37 .34 .32
8 .41 .35 .31 .41 .35 .31 .40 .35 .31 .39 .34 .31 .38 .34 .30 .29
9 .38 .32 .28 .38 .32 .28 .37 .32 .28 .36 .31 .28 .35 .31 .28 .26
10 .36 .30 .26 .35 .30 .26 .34 .29 .26 .34 .29 .26 .33 .29 .26 .24
Angle cd/1000 lm Angle cd/1000 lm
<EGSHL 1101/4 - DR> 0 227 50 149
5 214 55 154Lamp : MH100 (6500 lm)+
With Globe +
Reflector : +
FRP Dome Reflector
10 199 60 116
15 173 65 55.9
20 169 70 38.9
25 164 75 24.7
30 169 80 14.3
35 183 85 20.8
40 197 90 13.0
45 150
Coefficients of Utilization - Zonal Cavity%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .74 .74 .74 .72 .72 .72 .69 .69 .69 .66 .66 .66 .63 .63 .63 .62
1 .65 .63 .61 .64 .62 .60 .61 .60 .58 .59 .57 .56 .57 .56 .54 .53
2 .59 .55 .52 .58 .54 .51 .55 .53 .50 .53 .51 .49 .52 .50 .48 .47
3 .53 .48 .45 .52 .48 .45 .50 .47 .44 .49 .46 .43 .47 .45 .42 .41
4 .48 .43 .40 .47 .43 .39 .46 .42 .39 .44 .41 .38 .43 .40 .38 .37
5 .44 .39 .35 .43 .38 .35 .42 .38 .35 .41 .37 .34 .39 .36 .34 .33
6 .40 .35 .31 .39 .35 .31 .38 .34 .31 .37 .34 .31 .36 .33 .31 .29
7 .37 .32 .28 .36 .32 .28 .35 .31 .28 .34 .31 .28 .34 .30 .28 .27
8 .34 .29 .26 .33 .29 .26 .33 .29 .26 .32 .28 .25 .31 .28 .25 .24
9 .31 .27 .24 .31 .27 .24 .30 .26 .23 .30 .26 .23 .29 .26 .23 .22
10 .29 .25 .22 .29 .25 .22 .28 .24 .22 .28 .24 .22 .27 .24 .22 .21
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
EG Series
Wet Locations
Marine Locations
NEMA 3,3R,4,4X,7
Type of Explosion-proof
Class I Division 1 Group C,D
Flameproof (Ex d IIC T4 IP66)
Dust Ignition-proof (Ex DP II 12)
Features
<EG>
Options
Internal ballasts-separate ballasts
are not required. High power
factor (90%) ballasts reduce
power costs-allow more fixtures
per circuit.
Wide range of light sources to
meet specific lighting needs -
High Pressure Sodium (HPS):
150, 200, 250 and 400W,
Mercury Vapour (MV): 200, 250
and 400W, Metal Halide (MH):
175, 250 and 400W.
With Dome Reflector or 30°
Angle Reflector made of SMC
Instant Restrike (Max 150W HPS
only)
Fused to protect ballast and
capacitors
Quartz Auxiliary Lighting come to
full brightness immediately
(Non-hazardous location only,
Not available for use with 400W
MH or MV)
Standard Materials Compliance & Certification
Enclosure :
Die casting aluminium
Globe : Heat resistant hard glass
Lamp socket :
Porcelain with screw shell
Reflector :
Fiber glass Reinforced Polyester
Guard : Die casting aluminium
NEC - Class I Division 1 Group
C,D
UL 844 - Lighting Fixtures for
Use in Hazardous (Classified)
Locations
IEC 60079-0, 1
NEMA 3, 3R, 4, 4X, 7
Standard Finish Certification
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
UL Listed File No. E 131747
Certified by UL (Underwriters
Laboratories Inc), KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated Voltage AC110V/ 220V/ 240V 250W Ceiling EGNL 2251 21.9 ㎏
(Max. 460V for UL Listed) 400W Ceiling EGNL 2401 25.5 ㎏
Rated Wattage 150W/ 175W/ 200W/ 250W/
400W (Max 250W for UL Listed)
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp WattHub
SizePendant Ceiling Bracket Stanchion Certification
High
Pressure
Sodium
1501" EGNL 1151 EGNL 2151 EGNL 3151 EGNL 4151
Ex d IIC T4, Ex DP II 11,
Class I Division I Group C,D
3/4" EGNL 1153 EGNL 2153 EGNL 3153 EGNL 4153
2001" EGNL 1201 EGNL 2201 EGNL 3201 EGNL 4201
3/4" EGNL 1203 EGNL 2203 EGNL 3203 EGNL 4203
2501" EGNL 1251 EGNL 2251 EGNL 3251 EGNL 4251
3/4" EGNL 1253 EGNL 2253 EGNL 3253 EGNL 4253
4001" EGNL 1401 EGNL 2401 EGNL 3401 EGNL 4401
Ex d IIC T33/4" EGNL 1403 EGNL 2403 EGNL 3403 EGNL 4403
Metal
Halide
1751" EGHL 1171 EGHL 2171 EGHL 3171 EGHL 4171
Ex d IIC T4, Ex DP II 11,
Class I Division I Group C,D
3/4" EGHL 1173 EGHL 2173 EGHL 3173 EGHL 4173
2501" EGHL 1251 EGHL 2251 EGHL 3251 EGHL 4251
3/4" EGHL 1253 EGHL 2253 EGHL 3253 EGHL 4253
4001" EGHL 1401 EGHL 2401 EGHL 3401 EGHL 4401
Ex d IIC T2, Ex DP II 123/4" EGHL 1403 EGHL 2403 EGHL 3403 EGHL 4403
Mercury
Vapor
2001" EGML 1201 EGML 2201 EGML 3201 EGML 4201
Ex d IIC T3, Ex DP II 11,
Class I Division I Group C,D
3/4" EGML 1203 EGML 2203 EGML 3203 EGML 4203
2501" EGML 1251 EGML 2251 EGML 3251 EGML 4251
3/4" EGML 1253 EGML 2253 EGML 3253 EGML 4253
4001" EGML 1401 EGML 2401 EGML 3401 EGML 4401
Ex d IIC T33/4" EGML 1403 EGML 2403 EGML 3403 EGML 4403
Ordering Information Temperature Performance Data
E G N L 1 1 5 1 / 4 - DR Lamp Ambient Class I Flame Dust Ignition
① ② ③ ④ ⑤ ⑥ ⑦Type Watt. Temp ( )℃ Div. 1 Proof "d" Proof "DP"
EG Lighting Fixture① Entry Size⑤
High
Pressure
Sodium
15040 120 (T4A) T4 11
1 - 1" 55 - T4 -
3 - 3/4"200
40 120 (T4A) T4 11
Lamp Type② 5 - 1/2" 55 - T4 -
NL - High Pressure Sodium250
40 120 (T4A) T4 11
HL - Metal Halide 55 - T4 -
ML - Mercury Vapour Input Voltage (V)⑥ 400
40 - T3 -
1 - 110 55 - T3 -
2 - 120
Metal
Halide
17540 120 (T4A) T3 11
Mounting Type③ 3 - 208 55 - T3 -
1 - Pendant 4 - 220250
40 120 (T4A) T3 11
2 - Ceiling 5 - 240 55 - T3 -
3 - Bracket 6 - 277400
40 - T2 12
4 - Stanchion 7 - 460 55 - T2 -
Mercury
Vapor
20040 120 (T4A) T3 11
55 - T3 -
Lamp Wattage (W)④ Options⑦ 250
40 120 (T4A) T3 11
15 - 150 DR - Dome Type Reflector 55 - T3 -
17 - 175 AR - Angle Type Reflector400
40 - T3 -
20 - 200 IR - Instant Restrike Type 55 - T3 -
25 - 250 FU - Fused Type
40 - 400 QAL - Quartz Auxiliary Lighting Type
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
0 152 50 126<EGNL 1251/4 - DR>
5 148 55 128Lamp : NH250 (25000 lm)+
With Globe +
Reflector : FRP Dome +
Reflector
10 141 60 141
15 135 65 149
20 134 70 147
25 137 75 112
30 135 80 72.4
35 132 85 32.7
40 127 90 13.8
45 124
Coefficients of Utilization - Zonal Cavity
Multipliers%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
(For use with candlepower curves only)
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Lamp
Watts
Conversion
Factor
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .85 .85 .85 .83 .83 .83 .79 .79 .79 .76 .76 .76 .73 .73 .73 .71
1 .74 .70 .68 .72 .69 .67 .69 .67 .64 .66 .64 .62 .64 .62 .61 .59
250 1 2 .64 .59 .55 .63 .58 .54 .60 .56 .53 .58 .54 .52 .55 .53 .50 .49
3 .56 .50 .45 .55 .49 .45 .52 .48 .44 .50 .46 .43 .49 .45 .42 .41
200 0.8 4 .49 .43 .38 .48 .42 .37 .46 .41 .37 .45 .40 .36 .43 .39 .36 .34
5 .44 .37 .32 .43 .37 .32 .41 .36 .32 .40 .35 .31 .39 .34 .31 .29
150 0.56 6 .39 .33 .28 .39 .32 .28 .37 .32 .28 .36 .31 .27 .35 .31 .27 .26
7 .36 .29 .25 .35 .29 .25 .34 .28 .24 .33 .28 .24 .32 .27 .24 .23
8 .32 .26 .22 .32 .26 .22 .31 .26 .22 .30 .25 .22 .29 .25 .22 .20
9 .30 .24 .20 .29 .24 .20 .29 .23 .20 .28 .23 .20 .27 .23 .20 .18
10 .28 .22 .18 .27 .22 .18 .27 .22 .18 .26 .21 .18 .25 .21 .18 .17
Angle cd/1000 lm Angle cd/1000 lm
<EGHL 1251/4 - DR> 0 155 50 145
5 164 55 150Lamp : MH250 (20500 lm)+
With Globe +
Reflector : FRP Dome +
Reflector
10 170 60 151
15 164 65 158
20 167 70 162
25 162 75 141
30 154 80 49.9
35 153 85 22.9
40 148 90 10.5
45 140
Coefficients of Utilization - Zonal Cavity
Multipliers%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
(For use with candlepower curves only)
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Lamp
Watts
Conversion
Factor
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .96 .96 .96 .94 .94 .94 .90 .90 .90 .86 .86 .86 .82 .82 .82 .81
1 .84 .80 .77 .82 .79 .76 .78 .76 .74 .75 .73 .71 .72 .71 .69 .67
250 1 2 .73 .67 .63 .71 .66 .62 .68 .64 .61 .66 .62 .59 .63 .60 .58 .56
3 .64 .57 .52 .62 .56 .51 .60 .55 .50 .58 .53 .49 .56 .52 .49 .47
175 0.68 4 .56 .49 .43 .55 .48 .43 .53 .47 .43 .51 .46 .42 .49 .45 .41 .40
5 .50 .43 .37 .49 .42 .37 .47 .41 .37 .46 .40 .36 .44 .40 .36 .34
6 .45 .38 .32 .44 .37 .32 .43 .37 .32 .41 .36 .32 .40 .35 .31 .30
7 .41 .34 .29 .40 .33 .29 .39 .33 .28 .38 .32 .28 .37 .32 .28 .26
8 .37 .30 .26 .37 .30 .26 .36 .30 .25 .35 .29 .25 .34 .29 .25 .24
9 .34 .28 .23 .34 .28 .23 .33 .27 .23 .32 .27 .23 .31 .26 .23 .21
10 .32 .25 .21 .31 .25 .21 .31 .25 .21 .30 .25 .21 .29 .24 .21 .19
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<EGNL 1401/4 - DR> 0 132 50 136
5 134 55 138Lamp : NH400 (46000 lm)+
With Globe +
Reflector : FRP Dome +
Reflector
10 148 60 142
15 155 65 144
20 153 70 115
25 145 75 80.3
30 137 80 43.9
35 130 85 16.7
40 127 90 8.1
45 131
Coefficients of Utilization - Zonal Cavity%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .81 .81 .81 .79 .79 .79 .75 .75 .75 .72 .72 .72 .69 .69 .69 .68
1 .71 .68 .66 .69 .67 .65 .66 .64 .62 .64 .62 .61 .61 .60 .59 .57
2 .62 .58 .54 .61 .57 .53 .59 .55 .52 .56 .53 .51 .54 .52 .50 .48
3 .55 .49 .45 .54 .49 .45 .52 .47 .44 .50 .46 .43 .48 .45 .42 .41
4 .49 .43 .38 .48 .42 .38 .46 .41 .38 .44 .40 .37 .43 .39 .37 .35
5 .43 .37 .33 .43 .37 .33 .41 .36 .33 .40 .36 .32 .39 .35 .32 .30
6 .39 .33 .29 .39 .33 .29 .37 .32 .29 .36 .32 .28 .35 .31 .28 .27
7 .36 .30 .26 .35 .30 .26 .34 .29 .25 .33 .29 .25 .32 .28 .25 .24
8 .33 .27 .23 .32 .27 .23 .31 .26 .23 .30 .26 .23 .30 .26 .23 .21
9 .30 .25 .21 .30 .24 .21 .29 .24 .21 .28 .24 .21 .27 .23 .20 .19
10 .28 .23 .19 .28 .22 .19 .27 .22 .19 .26 .22 .19 .26 .22 .19 .18
Angle cd/1000 lm Angle cd/1000 lm
<EGHL 1401/4 - DR> 0 133 50 102
5 132 55 122Lamp : MH400 (34000 lm)+
With Globe +
Reflector : FRP Dome +
Reflector
10 142 60 126
15 150 65 111
20 140 70 105
25 132 75 80.6
30 125 80 30.0
35 119 85 16.9
40 109 90 8.9
45 98.0
Coefficients of Utilization - Zonal Cavity%Effective Ceiling
Cavity Reflectance( cc)ρ80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .70 .70 .70 .69 .69 .69 .66 .66 .66 .63 .63 .63 .60 .60 .60 .59
1 .62 .59 .57 .60 .58 .56 .58 .56 .54 .55 .54 .53 .53 .52 .51 .50
2 .54 .50 .47 .53 .49 .46 .51 .48 .45 .49 .46 .44 .47 .45 .43 .42
3 .48 .43 .39 .47 .42 .39 .45 .41 .38 .43 .40 .37 .42 .39 .37 .36
4 .42 .37 .33 .42 .37 .33 .40 .36 .33 .39 .35 .32 .37 .34 .32 .31
5 .38 .33 .29 .37 .32 .29 .36 .32 .28 .35 .31 .28 .34 .30 .28 .27
6 .34 .29 .25 .34 .29 .25 .33 .28 .25 .32 .28 .25 .31 .27 .25 .23
7 .31 .26 .23 .31 .26 .23 .30 .25 .22 .29 .25 .22 .28 .25 .22 .21
8 .29 .24 .20 .28 .24 .20 .27 .23 .20 .27 .23 .20 .26 .23 .20 .19
9 .26 .22 .19 .26 .22 .18 .25 .21 .18 .25 .21 .18 .24 .21 .18 .17
10 .25 .20 .17 .24 .20 .17 .24 .20 .17 .23 .19 .17 .23 .19 .17 .16
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< EG Bracket Type > < EG Stanchion Type >
< EG Ceiling Type > < EG Pendant Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures Pole Type
Explosion proof & Vaportight
Weathertight
NEMA 3, 3R, 5
Lighting
FixturesConstruction Lamps
Lamp
Watt
Catalog Number
Hand Rail Type Pedestal Type
2.5M Height 3.5M Height 2.5M Height 3.5M Height
EAEx d IIC T4
Ex d IIB T4
High
Pressure
Sodium
150 EANLP20915-25H EANLP20915-35H EANLP20915-25P EANLP20915-35P
200 EANLP20920-25H EANLP20920-35H EANLP20920-25P EANLP20920-35P
250 EANLP20925-25H EANLP20925-35H EANLP20925-25P EANLP20925-35P
Mercury
Vapor
200 EAMLP20920-25H EAMLP20920-35H EAMLP20920-25P EAMLP20920-35P
250 EAMLP20925-25H EAMLP20925-35H EAMLP20925-25P EAMLP20925-35P
400 EAMLP20940-25H EAMLP20940-35H EAMLP20940-25P EAMLP20940-35P
Metal
Halide
175 EAHLP20917-25H EAHLP20917-35H EAHLP20917-25P EAHLP20917-35P
250 EAHLP20925-25H EAHLP20925-35H EAHLP20925-25P EAHLP20925-35P
400 EAHLP20940-25H EAHLP20940-35H EAHLP20940-25P EAHLP20940-35P
SR Ex nR II T3
High
Pressure
Sodium
50 SRNLP20905-25H SRNLP20905-35H SRNLP20905-25P SRNLP20905-35P
70 SRNLP20907-25H SRNLP20907-35H SRNLP20907-25P SRNLP20907-35P
100 SRNLP20910-25H SRNLP20910-35H SRNLP20910-25P SRNLP20910-35P
150 SRNLP20915-25H SRNLP20915-35H SRNLP20915-25P SRNLP20915-35P
20 SRNLP20920-25H SRNLP20920-35H SRNLP20920-25P SRNLP20920-35P
250 SRNLP20925-25H SRNLP20925-35H SRNLP20925-25P SRNLP20925-35P
Mercury
Vapor
100 SRMLP20910-25H SRMLP20910-35H SRMLP20910-25P SRMLP20910-35P
200 SRMLP20920-25H SRMLP20920-35H SRMLP20920-25P SRMLP20920-35P
250 SRMLP20925-25H SRMLP20925-35H SRMLP20925-25P SRMLP20925-35P
400 SRMLP20940-25H SRMLP20940-35H SRMLP20940-25P SRMLP20940-35P
Metal
Halide
100 SRHLP20910-25H SRHLP20910-35H SRHLP20910-25P SRHLP20910-35P
175 SRHLP20917-25H SRHLP20917-35H SRHLP20917-25P SRHLP20917-35P
250 SRHLP20925-25H SRHLP20925-35H SRHLP20925-25P SRHLP20925-35P
400 SRHLP20940-25H SRHLP20940-35H SRHLP20940-25P SRHLP20940-35P
VDY IP55
High
Pressure
Sodium
50 VDNLP20905-25H VDNLP20905-35H VDNLP20905-25P VDNLP20905-35P
70 VDNLP20907-25H VDNLP20907-35H VDNLP20907-25P VDNLP20907-35P
100 VDNLP20910-25H VDNLP20910-35H VDNLP20910-25P VDNLP20910-35P
150 VDNLP20915-25H VDNLP20915-35H VDNLP20915-25P VDNLP20915-35P
200 VDNLP20920-25H VDNLP20920-35H VDNLP20920-25P VDNLP20920-35P
250 VDNLP20925-25H VDNLP20925-35H VDNLP20925-25P VDNLP20925-35P
Mercury
Vapor
100 VDMLP20910-25H VDMLP20910-35H VDMLP20910-25P VDMLP20910-35P
200 VDMLP20920-25H VDMLP20920-35H VDMLP20920-25P VDMLP20920-35P
250 VDMLP20925-25H VDMLP20925-35H VDMLP20925-25P VDMLP20925-35P
400 VDMLP20940-25H VDMLP20940-35H VDMLP20940-25P VDMLP20940-35P
Metal
Halide
100 VDHLP20910-25H VDHLP20910-35H VDHLP20910-25P VDHLP20910-35P
175 VDHLP20917-25H VDHLP20917-35H VDHLP20917-25P VDHLP20917-35P
250 VDHLP20925-25H VDHLP20925-35H VDHLP20925-25P VDHLP20925-35P
400 VDHLP20940-25H VDHLP20940-35H VDHLP20940-25P VDHLP20940-35P
FeaturesThese pole type fittings are the combinations
of lighting units for EA, SR type Lighting
Fixtures, goose neck shaped poles and EC
type ballasts.
They are mainly used for tower illumination of
chemical plants where high illumination long life
service are required.
The construction of the ballast and the
mounting box are the same as those of
flameproof EA and non-sparking SR type
Lighting Fittings.
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures with 7M Pole Type
Explosion proof & Vaportight
Weathertight
NEMA 3, 3R, 5
Lighting
FixturesConstruction Lamps
Lamp
Watt
Catalog Number
PHR PHY PHL
EAEx d IIC T4
Ex d IIB T4
High Pressure
Sodium
200 EANPHR920 EANPHY920 EANPHL920
250 EANPHR925 EANPHY925 EANPHL925
400 EAMPHR940 EAMPHY940 EAMPHL940
Mercury Vapor250 EAMPHR925 EAMPHY925 EAMPHL925
400 EAHPHR940 EAHPHY940 EAHPHL940
Metal Halide250 EAHPHR925 EAHPHR925 EAHPHL925
400 EAHPHR940 EAHPHR940 EAHPHR940
SR Ex nR II T3
High Pressure Sodium
200 SRNPHR920 SRNPHY920 SRNPHL920
250 SRNPHR925 SRNPHY925 SRNPHL925
400 SRMPHR940 SRMPHY940 SRMPHL940
Mercury Vapor250 SRMPHR925 SRMPHY925 SRMPHL925
400 SRHPHR940 SRHPHY940 SRHPHL940
Metal Halide250 SRHPHR925 SRHPHR925 SRHPHL925
400 SRHPHR940 SRHPHR940 SRHPHL940
Features
These lighting equipments are furnished with flameproof or non-sparking lighting fixtures on the top of poles the ballasts and the connection facilities for supply cables are provided in the lower part of the poles. The constructions of lighting units are almost the same as those of EA, SR type Lighting Fixtures.The poles supplied in three different shapes of heads, such as Types PHR, PHY and PHL.Each of them is classified in three kinds according to the types of protection of ballast housings, and in each one of the ballast housings is installed a flameproof or increase-safety ballasts. Standard poles are Anchor base type pedestal type poles, Embedded type or others are supplied to special order.
<PHR> <PHL>
If you need more information, contact us please. ⇨
HID Ballast
Copyright by NAMBUK Electric Co., LTD. 2004
Flameproof HID Ballast
Exterior Series
< SB Type >< UB Type >
Application Standard Materials
In consideration of various environmental conditions
in hazardous areas, MB Mercury ballast and NB
Sodium ballasts and HB Metal Halide ballasts are
designed for maintaining much safety of strength and
weatherproofness of enclosure and low
temperature-rise of windings.
These ballasts are the same types as those attached
to flameproof type lighting fixtures, as EA, EU, EXFD
(flood lighting), increase safety type lighting fixtures,
as SR, SGFD(flood lighting), and Vaportight type
lighting Fixtures, as VDY, VS the special design
features, such as electrical characteristics and wiring
diagrams described on next page, are applicable to
the ballasts of above fitting.
SB Body : Steel
UB Body : Cast aluminium alloy
End Cover : Die Casting aluminium
Mounting box : Cast aluminium alloy
Attention
Supply voltages shall be as close as rated voltage :
In general, allowable fluctuation of supply voltages
are ±5% for choke type ballasts, and ±10% for
constant wattage type ballasts.
Wattages and frequencies other than rating must be
avoided.:
Especially, the use of smaller lamp and the use of
60Hz ballast on 50Hz circuit give much danger in
explosion protection.
Allowable ambient temperature for standard units it
from -20 to 55 :℃ ℃
When the mercury and Sodium Lamp ballasts are
used in lower or higher temperature, special
considerations are necessary Further information will
be given on request.
Features
The SB body is made of thick wall steel pipe, it is
extremely strong against the pressure of internal and
external impact.
UB type is unite ballast body with mounting box.
The capacitor is attached not embedded in the
compound so as to eliminate the influence of heat
of windings.
Ordering Information
S M B 1 1 0 ① ② ③ ④
S : Standard Type Ballast① Ballast Type② Voltage (V)③ Wattage (W)④
U : Unite Type Ballast NB - High Pressure Sodium 1 - 110 05 : 50
HB - Metal Halide 2 - 220 07 : 70
MB - Mercury Vapor 3 - 240 10 : 100
4 - 460 15 : 150
17 : 175
20 : 200
25 : 250
40 : 400
HID Ballast
Copyright by NAMBUK Electric Co., LTD. 2004
Electrical Data
BallastWatts
(W)
Input
Volts
(V)
Input
Current
(A)
Input
Watts
(W)
Short
Circuit
Current (A)
Secondary
Volts
(V)
Secondary
Current
(A)
Metal
Halide
100 220 0.55 110 1.6 250 1.0
175 220 1.05 210 1.6 300 1.5
250 220 1.4 280 2.5 300 2.1
400 220 2.2 460 3.8 300 3.25
High
Pressure
Sodium
50 220 0.29 57.5 0.9 220 0.76
70 220 0.4 80 1.2 220 1.0
100 220 0.55 110 1.6 220 1.2
150 220 0.8 160 2.3 220 1.8
200 220 1.1 220 3.0 220 2.3
250 220 1.38 275 3.75 220 3.0
400 220 2.2 436 6.0 220 4.6
Mercury
Vapour
200 220 1.0 205 3.0 220 1.7
400 220 2.15 430 5.7 220 3.25
Dimensions (mm)
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Accessary & Component
Globe Guard
GL 13 GL 21GD 13
GD 25
GL 20 GL 23GD 22
GD 27
GL 20MGD 22M
Cat. No Lamp Watts Fixture Series Material Cat. No Lamp Watts Fixture
Series Material
GL 13 50 - 100 VG Heat impact resistant GD 13 50 - 100 VG Al die casting
GL 20 150 - 250 VN, EVN Heat impact resistant GD 22 150 - 250 VN, EVN Stainless Steel
GL 20M 250 - 400 VZ Heat impact resistant GD 22M 250 - 400 VZ Stainless Steel
GL 21 50 - 100 EGS Heat impact resistant GD 25 50 - 100 EGS Al die casting
GL 23 150 - 400 EG Heat impact resistant GD 27 150 - 400 EG Al die casting
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Reflector
DR 32DR 43
DR 44
DR 43F
AR 32 AR 43AR 43F
Cat. No Lamp Watts Fixture Series Material
DR 32 50 - 100 EGS, VG Aluminium
DR 43 150 - 400 EG, VN, EVN, VZ Aluminium
DR 44 400 EGFD Aluminium
AR 32 50 - 100 EGS, VG Aluminium
DR 43F 150 - 250 EG, VN, EVN, VZ FRP
AR 43F 150 -250 EG, VN, EVN, VZ FRP
SECTION - 3L
Fluorescent Lighting Fixture
SECTION 3L
Fluorescent Lighting Fixtures INDEX
Model
Lamp Type / Watt. Certification for Explosion-proof
PAGE
Fluorescent IEC
18 20 26 32 36
VDFL(S)1
2
1
2
1
2
1
2
1
2Weatherproof Type 3L - 1
VEFL1
2
1
2
1
2
1
2
1
2
Ex de IIC T4 IP66
Ex eds IIC T43L - 3
SYFL1
2
1
2
1
2
1
2
1
2Ex nR II T6 3L - 5
SGFL
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
Ex nR II T6 3L - 8
EXFL1
2
1
2
1
2
1
2
1
2
Ex d IIB T6
Ex d IIC T63L - 10
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Fluorescent Vaportight Lighting Fixtures
VDFL(S) Series
Weatherproof Type
NEMA 4, 4X, 7
<VDFL(S) 18W>
<VDFL(S) 36W>
Application Features
VDFL(S) Series Fluorescent lighting fixtures are used ;
in installations where moisture, dirt, dust,
vibration, corrosion and rough usage are
problems.
Simple construction of enclosures.
Safety operation and ease of maintenance.
With the electronic ballast or Inductive ballast to be high
power factor, and integral emergency light.
With folding protective bowl of polycarbonate without
wire guard for the most efficient light distribution.
To open cover, insert tool (8mm Hex Wrench or 13mm
Socket Wrench) in key hole and turn right or left 90° as
below figure.
For single- and two-pin fluorescent lamps
All-pole disconnection via N/C switch when opening
cover or battery enclosure.
Maintained emergency operation 1.5h or 3h
Standard Materials
Body : Glass fiber polyester
Globe : Polycarbonate
Inner Reflector : High purity aluminium
Compliance
IP66
Standard Finish
Natural
If you want another color, contact us please.
Technical Data WeightElectrical Rating Catalog No. Weight
Rated Voltage AC110V/ 220V/ 240V VDFL(S) 31212 5 Kg
Rated Wattage18W/ 18W×2/ 20W/ 20W×2/
32W/ 32W×2/ 36W/ 36W×2/ VDFL(S) 31252 8 Kg
If you need more information, ⇨
contact us please
Battery 7Ah NiCd-Battery
Emergency light operation time 1.5h 3h
Emergency light power18W 90% 45%
36W 45% 25%
Entry Size 1/2", 3/4", 1"
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number Ordering Information
Lamp Watt(W) Voltage(V)Catalog
Number
V D F L (S ) 3 1 1 4 1 ① ② ③ ④ ⑤ ⑥
Fluorescent
Lamp
18W×1110 VDFL(S) 31111 Lighting Fixture Type ①
220 VDFL(S) 31211 VDFL(S) Fluorescent Lighting Fixture
18W×2110 VDFL(S) 31112 Ballast Type② Lamp Wattage (W)⑤
220 VDFL(S) 31212 3 - Internal Ballast 1 - 18
32W×1110 VDFL(S) 31131 4 - Emergency Type 2 - 20
220 VDFL(S) 31231 Mounting Type③ 3 - 32
32W×2110 VDFL(S) 31132 4 - 40
220 VDFL(S) 31232 Voltage (V)④ 5 - 36
36W×1110 VDFL(S) 31151 1 - 110
220 VDFL(S) 31251 2 - 220 Quantity of ⑥ Lamp
36W×2110 VDFL(S) 31152 3 - 230 1 - ×1
220 VDFL(S) 31252 4 - 240 2 - ×2
Photometric Data
<VDFL(S) 31252> 0 -180 (Blue)˚ ˚ 90 -270 (Red)˚ ˚
Angle cd/1000 lm Angle cd/1000 lmLamp : FL36×2+
(2×2500 lm)
With globe and guard+
0 169 0 169
10 158 10 169
20 158 20 156
30 146 30 145
40 124 40 145
50 101 50 133
right picture explanation☞
Blue : Normal to Lamp+
Red : Parallel to Lamp+
60 79 60 120
70 56 70 109
80 23 80 85
90 5 90 60
Dimension
<VDFL(S)>
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Fluorescent Lighting Fixtures
VEFL Series
Wet Locations
NEMA 4, 4X, 7
Type of Explosion-proof
Flameproof-Increase Safety (Ex ed IIC T4 IP66)
Flameproof-Increase Safety-Special (Ex eds IIC T4 IP66)
<VEFL 18W>
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Fluorescent Lighting Fixtures
VEFL Series
Wet Locations
NEMA 4, 4X, 7
Type of Explosion-proof
Flameproof-Increase Safety (Ex ed IIC T4 IP66)
Flameproof-Increase Safety-Special (Ex eds IIC T4 IP66)
<VEFL 18W>
<VEFL 36W>
Application Features
VEFL Series Fluorescent lighting fixtures are used ;
were ignitable concentrations of flammable gases,
vapors or liquids can exist all of the time or
some of the time under normal operation
conditions.
in installations where moisture, dirt, dust,
vibration, corrosion and rough usage are
problems.
Simple construction of enclosures.
Safety operation and ease of maintenance.
With the electronic ballast or Inductive ballast to be
high power factor, and integral emergency light.
With folding protective bowl of polycarbonate without
wire guard for the most efficient light distribution.
To open cover, insert tool (8mm Hex Wrench or 13mm
Socket Wrench) in key hole and turn right or left 90° as
below figure.
For single- and two-pin fluorescent lamps
All-pole disconnection via N/C switch when opening
cover or battery enclosure.
Maintained emergency operation 1.5h or 3h
Standard Materials Body : Glass fiber polyester
Globe : Polycarbonate
Inner Reflector : Engineering Plastic
Compliance
IEC 60079-0, 1. 7
Certification Certified by KOSHA (Korea Occupational Safety &
Health Agency), KGS (Korea Gas Safety
Corporation), and the others.
Standard Finish Natural
If you want another color, contact us please.
Technical Data WeightElectrical Rating Catalog No. Weight
Rated Voltage AC110V/ 220V/ 240V VEFL 31212 5 Kg
Rated Wattage18W/ 18W×2/ 20W/ 20W×2/
32W/ 32W×2/ 36W/ 36W×2/ VEFL 31252 8 Kg
⇨ If you need more
information, contact us please
Battery 7Ah NiCd-Battery
Emergency light operation time 1.5h 3h
Emergency light power18W 90% 45%
36W 45% 25%
Entry Size 1/2", 3/4", 1"
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number Ordering Information
Lamp Watt(W) Voltage(V)Catalog
Number V E F L 3 1 1 4 1 ① ② ③ ④ ⑤ ⑥
Fluorescent
Lamp
18W×1110 VEFL 31111 ① VEFL Lighting Fixture ② Ballast Type
220 VEFL 31211 ③ Mounting Type 3 - General Type
18W×2110 VEFL 31112 1 - Pendant 4 - Emergency Type
220 VEFL 31212 2 - Ceiling
32W×1110 VEFL 31131 3 - Wall Bracket ④ Voltage (V)
220 VEFL 31231 4 - Hexagonal Screw 1 - 110
32W×2110 VEFL 31132 5 - Eye Bolt 2 - 220
220 VEFL 31232 6 - Pipe Clamp 3 - 230
36W×1110 VEFL 31151 ⑤ Lamp Wattage (W) 4 - 240
220 VEFL 31251 1 - 18
36W×2110 VEFL 31152 2 - 20 ⑥ Quantity of Lamp
220 VEFL 31252 3 - 32 1 - ×1
Photometric Data 4 - 40 2 - ×2
5 - 36
<VEFL 31252> 0˚-180˚(Blue) 90˚-270˚(Red)
Angle cd/1000 lm Angle cd/1000 lm+Lamp : FL36×2
(2×2500 lm)
+With globe and guard
0 169 0 169
10 158 10 169
20 158 20 156
30 146 30 145
40 124 40 145
50 101 50 133
☞right picture explanation
+Blue : Normal to Lamp
+Red : Parallel to Lamp
60 79 60 120
70 56 70 109
80 23 80 85
90 5 90 60
Dimension
<VEFL>
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Fluorescent (Emergency) Lighting Fixtures
SYFL Series
Wet Locations
NEMA 3, 3R, 7
Type of Explosion-proof
Non - Sparking (Ex nR II T6)
Application Features
SYFL Series fluorescent lighting fixtures are used ;
in heavy process industries having environments
where flammable or explosive vapors or gases are
present.
in hazardous areas, both indoors and outdoors
where long life and low maintenance costs are
desired.
in petroleum refineries, chemical, petrochemical
and other heavy process industry facilities.
were ignitable concentrations of flammable gases,
vapors or liquids can exist all of the time or some
of the time under normal operation conditions.
in installations where moisture, dirt, dust, vibration,
corrosion and rough usage are problems.
The lighting unit consists of the main body and the
reflector, both made of pressed sheet steel, and one
or two lamp cover assemblies.
The lamp cover is sealed at each and into the
lampholder casing by synthetic rubber packing, and an
access cover to the relamping lampholder is provided
so as to restrict breathing. The cover for replacement
of lamp at the end of one lampholder casing.
The ballast is made in compliance with the increased
safety requirements, and is mounted to the reverse
side of the main body.
The guard is designed to be able to open at either
side by releasing two fixing screws. This allows easy
cleaning of the lamp cover.
<SYFL 31152>
Standard Materials Certification Standard Finish Enclosure : Sheet steel
Lamp cover :
Heat resistant hard tubing glass
Guard : Stainless steel
Reflector : Sheet steel
(Stove enamelled white inside)
Suspension stem :
Heavy gauge steel pipe
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Compliance Weight
IEC 60079-0, 1, 7
NEMA 3, 3R, 7
Catalog No. Weight
SYFL 31152 11.8 ㎏
Technical Data Emergency
Electrical Rating Battery Rating
Rated Voltage AC110V/ 220V/ 240VDC 9.6V 1.2Ah
Rated Wattage 18W/ 18W×2/ 20W/ 20W×2/
32W/ 32W×2/ 36W/ 36W×2/ Operating Time
Rated Frequency 50Hz/ 60Hz30min or 1hr
Entry Size 1/2", 3/4", 1"
Relamping
Lamp housing is sloped as
shown for ease of relamping (no
space needed between fixtures
for relamping)
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Type Watt Voltage(V) Pendant Ceiling 90° Bracket 40° Bracket Certification
Fluorescent
Lighting
Fixture
18W×1110 SYFL 31121 SYFL 32121 SYFL 33121 SYFL 34121
Ex nR II T6
220 SYFL 31221 SYFL 32221 SYFL 33221 SYFL 34221
18W×2110 SYFL 31122 SYFL 32122 SYFL 33122 SYFL 34122
220 SYFL 31222 SYFL 32222 SYFL 33222 SYFL 34222
20W×1110 SYFL 31121 SYFL 32121 SYFL 33121 SYFL 34121
220 SYFL 31221 SYFL 32221 SYFL 33221 SYFL 34221
20W×2110 SYFL 31122 SYFL 32122 SYFL 33122 SYFL 34122
220 SYFL 31222 SYFL 32222 SYFL 33222 SYFL 34222
32W×1110 SYFL 31131 SYFL 32131 SYFL 33131 SYFL 34131
220 SYFL 31231 SYFL 32231 SYFL 33231 SYFL 34231
32W×2110 SYFL 31132 SYFL 32132 SYFL 33132 SYFL 34132
220 SYFL 31232 SYFL 32232 SYFL 33232 SYFL 34232
36W×1110 SYFL 31151 SYFL 32151 SYFL 33151 SYFL 34151
220 SYFL 31251 SYFL 32251 SYFL 33251 SYFL 34251
36W×2110 SYFL 31152 SYFL 32152 SYFL 33152 SYFL 34152
220 SYFL 31252 SYFL 32252 SYFL 33252 SYFL 34252
Emergency
Fluorescent
Lighting
Fixture
18W×1110 SYEFL 31121 SYEFL 32121 SYEFL 33121 SYEFL 34121
220 SYEFL 31221 SYEFL 32221 SYEFL 33221 SYEFL 34221
18W×2110 SYEFL 31122 SYEFL 32122 SYEFL 33122 SYEFL 34122
220 SYEFL 31222 SYEFL 32222 SYEFL 33222 SYEFL 34222
20W×1110 SYEFL 31121 SYEFL 32121 SYEFL 33121 SYEFL 34121
220 SYEFL 31221 SYEFL 32221 SYEFL 33221 SYEFL 34221
20W×2110 SYEFL 31122 SYEFL 32122 SYEFL 33122 SYEFL 34122
220 SYEFL 31222 SYEFL 32222 SYEFL 33222 SYEFL 34222
32W×1110 SYEFL 31131 SYEFL 32131 SYEFL 33131 SYEFL 34131
220 SYEFL 31231 SYEFL 32231 SYEFL 33231 SYEFL 34231
32W×2110 SYEFL 31132 SYEFL 32132 SYEFL 33132 SYEFL 34132
220 SYEFL 31232 SYEFL 32232 SYEFL 33232 SYEFL 34232
36W×1110 SYEFL 31151 SYEFL 32151 SYEFL 33151 SYEFL 34151
220 SYEFL 31251 SYEFL 32251 SYEFL 33251 SYEFL 34251
36W×2110 SYEFL 31152 SYEFL 32152 SYEFL 33152 SYEFL 34152
220 SYEFL 31252 SYEFL 32252 SYEFL 33252 SYEFL 34252
Ordering Information
S Y F L 3 1 1 2 1 ① ② ③ ④ ⑤ ⑥
Lighting Fixture Type① Ballast Type② Mounting Type③
SYFL - Increase Safety Fluorescent Lighting Fixture 3 - Internal Ballast 1 - Pendant
SYEFL - Emergency Fluorescent Lighting Fixture 2 - Ceiling
3 - 90° Bracket
Voltage (V)④ Lamp Wattage (W)⑤ Quantity of ⑥ Lamp 4 - 40° Bracket
1 - 110 1 - 18 1 - ×1
2 - 220 2 - 20 2 - ×2
3 - 230 3 - 32
4 - 240 4 - 40
5 - 36
Photometric Data
Anglecd/1000 lm
Anglecd/1000 lm
Blue Red Blue Red<SYFL 32152>0 201.3 201.3 50 160.0 116.3
Lamp : FL36×2+
(2×2500 lm)
With Globe and Guard+
5 201.3 195.0 55 146.3 101.3
10 201.3 192.5 60 135.0 83.8
15 200.0 188.8 65 128.8 65.0
20 191.3 182.5 70 123.8 47.5
25 185.0 175.0 75 110.0 30.0
30 180.0 166.3 80 82.5 16.3right picture explanation☞
Blue : Normal to Lamp+
Red : Parallel to Lamp+
35 175.0 156.3 85 68.8 7.5
40 170.0 143.8 90 50.0 2.5
45 165.0 131.3
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
< SYFL > < Pendant Type >
< 40° Bracket Type > < 90° Bracket Type > < Ceiling Type >
< SYEFL Series > < Pendant Type >
< 40° Bracket Type > < 90° Bracket Type > < Ceiling Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Fluorescent (Emergency) Lighting Fixtures
SGFL Series
Recessed Type
Booth Type
Type of Explosion-proof
Non - Sparking (Ex nR II T6)
Application Features
SGFL Series fluorescent lighting fixtures are used ;
in heavy process industries having environments
where flammable or explosive vapors or gases are
present.
in hazardous areas, both indoors and outdoors
where long life and low maintenance costs are
desired.
in petroleum refineries, chemical, petrochemical
and other heavy process industry facilities.
where ignitable concentrations of flammable gases,
vapors or liquids can exist all of the time or some
of the time under normal operation conditions.
in installations where moisture, dirt, dust, vibration,
corrosion and rough usage are problems.
The lighting fixture consist of the main body and the
inside reflector, both made of pressed sheet steel, and
1-5 lamp cover assemblies.
The lamp cover is sealed at each end into the
lampholder casing by synthetic rubber packing, and an
access cover to the relamping lampholder is provided
so as to restrict breathing.
The guard is designed to be able to open at either
side by releasing 4 fixing screws to down guard by
two hinges.
<SGFL 86252>
Standard Materials Certification Compliance
Enclosure : Sheet steel
Lamp cover : Heat resistant hard
tubing glass
Guard : Stainless steel
Reflector : Sheet steel (Stove
enamelled white inside)
Lamp holder casing : Urea resin
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
IEC 60079-0, 15
NEMA 3, 3R, 7
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Technical Data Emergency
Electrical Rating Battery Rating
Rated Voltage AC110V/ 220V/ 240VDC 9.6V 1.2Ah
Rated Wattage 32W/ 36W/
×1/ ×2/ ×3/ ×4/ ×5 Operating Time
Rated Frequency 50Hz/ 60Hz30min or 1hr
Entry Size 1/2", 3/4", 1"
WeightCatalog No. Weight
SGFL 86252 37 ㎏
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Type Watt Voltage Catalog No. Certification
<SGFL 86>
<SGFL 87>
Fluorescent
Lamp
Recessed
Type
20W×1110 SGFL 86121
Ex nR II T6
220 SGFL 86221
20W×2110 SGFL 86122
220 SGFL 86222
36W×1110 SGFL 86151
220 SGFL 86251
36W×2110 SGFL 86152
220 SGFL 86252
36W×3110 SGFL 86153
220 SGFL 86253
36W×4110 SGFL 86154
220 SGFL 86254
Booth
Type
36W×1110 SGFL 87151
220 SGFL 87251
36W×2110 SGFL 87152
220 SGFL 87252
36W×3110 SGFL 87153
220 SGFL 87253
36W×4110 SGFL 87154
220 SGFL 87254
36W×5110 SGFL 87155
220 SGFL 87255
Emergency
Type
36W×1110 SGEFL 87151
220 SGEFL 87251
36W×2110 SGEFL 87152
220 SGEFL 87252
36W×3110 SGEFL 87153
220 SGEFL 87253
36W×4110 SGEFL 87154
220 SGEFL 87254
36W×5110 SGEFL 87155
220 SGEFL 87255
Ordering Information S G F L 3 1 1 4 1 ① ② ③ ④ ⑤ ⑥
Lighting Fixture Type① ② Model Type
SGFL - Fluorescent Lighting 86 - Recessed Type
SGEFL - Emergency Type 87 - Booth Type
Voltage (V)③ ④ Lamp Wattage (W) ⑤ Quantity of Lamp
1 - 110 1 - 18 1 - ×1
2 - 220 2 - 20 2 - ×2
3 - 230 3 - 32 3 - ×3
4 - 240 4 - 40 4 - ×4
5 - 36 5 - ×5
Photometric Data0 -180 (Blue)˚ ˚ 90 -270 (Red)˚ ˚
Angle cd/1000 lm Angle cd/1000 lm
0 183 0 183<SGFL 86232>10 183 10 183
Lamp : FL32×2(6000 lm)+
With globe and guard+20 169 20 169
30 155 30 155
40 141 40 127
50 127 50 84
60 84 60 56right picture explanation☞
Blue : Normal to Lamp+
Red : Parallel to Lamp+
70 42 70 14
80 14 80 0
90 0 90 0
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Fluorescent (Emergency) Lighting Fixtures
EXFL Series
Wet Locations
NEMA 3, 3R, 4, 4X, 7
Type of Explosion-proof
Flameproof (Ex d IIB T6 IP66)
Flameproof (Ex d IIC T6 IP66)
Application Features EXFL Series Fluorescent lighting fixtures are used ;
in heavy process industries having environments
where flammable or explosive vapors or gases are
present.
in hazardous areas, both indoors and outdoors
where long life and low maintenance costs are
desired.
in petroleum refineries, chemical, petrochemical
and other heavy process industry facilities.
where ignitable concentrations of flammable gases,
vapors or liquids can exist all of the time or some
of the time under normal operation conditions.
in installations where moisture, dirt, dust, vibration,
corrosion and rough usage are problems.
The flameproof enclosures of lamp and ballast are
separated from each other with barrier walls and
sealing glands.
The lamp housing has a tubular lamp cover cemented
into the lampholder casings at the both ends. One
casing contains a fixed lampholder and the other a
relamping lampholder.
The sloping device is provided at the mounting base of
relamping side. The lamp housing can be sloped by
releasing two fixing screws for easier replacement of
the lamp.
The guard is designed to be able to open at either
side by releasing two fixing screws. It is convenient to
clean the lamp cover.
<EXFL 21252>
Standard Materials Certification Standard Finish Enclosure : Cast aluminium alloy
Lamp cover :
Heat resistant hard tubing glass
Guard : Steel
Reflector : Sheet steel
(Stove enamelled white inside)
Suspension stem :
Heavy gauge steel pipe
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Compliance Weight
IEC 60079-0, 1
NEMA 3, 3R, 4, 4X, 7
Catalog No. Weight
EXFL 21252 11.4㎏
Technical Data Emergency
Electrical Rating Battery Rating
Rated Voltage AC110V/ 220V/ 240VDC 9.6V 1.2Ah
Rated Wattage 18W/ 18W×2/ 20W/ 20W×2/
32W/ 32W×2/ 36W/ 36W×2/ Operating Time
Rated Frequency 50Hz/ 60Hz30min or 1hr
Entry Size 1/2", 3/4", 1"
Relamping
Lamp housing is sloped as
shown for ease of relamping (no
space needed between fixtures
for relamping)
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt Volt Pendant Ceiling 90° Bracket 40° Bracket Certification
Fluorescent
Lamp
18W×1110 EXFL 21111 EXFL 22111 EXFL 23111 EXFL 24111
Ex d IIB T6 IP66220 EXFL 21211 EXFL 22211 EXFL 23211 EXFL 24211
18W×2110 EXFL 21112 EXFL 22112 EXFL 23112 EXFL 24112
220 EXFL 21212 EXFL 22212 EXFL 23212 EXFL 24212
18W×1110 EXFL 21111-H EXFL 22111-H EXFL 23111-H EXFL 24111-H
Ex d IIC T6220 EXFL 21211-H EXFL 22211-H EXFL 23211-H EXFL 24211-H
18W×2110 EXFL 21112-H EXFL 22112-H EXFL 23112-H EXFL 24112-H
220 EXFL 21212-H EXFL 22212-H EXFL 23212-H EXFL 24212-H
32W×1110 EXFL 21131 EXFL 22131 EXFL 23131 EXFL 24131
Ex d IIB T6220 EXFL 21231 EXFL 22231 EXFL 23231 EXFL 24231
32W×2110 EXFL 21132 EXFL 22132 EXFL 23132 EXFL 24132
220 EXFL 21232 EXFL 22232 EXFL 23232 EXFL 24232
32W×1110 EXFL 21131-H EXFL 22131-H EXFL 23131-H EXFL 24131-H
Ex d IIC T6220 EXFL 21231-H EXFL 22231-H EXFL 23231-H EXFL 24231-H
32W×2110 EXFL 21132-H EXFL 22132-H EXFL 23132-H EXFL 24132-H
220 EXFL 21232-H EXFL 22232-H EXFL 23232-H EXFL 24232-H
Emergency
Fluorescent
Lamp
18W×1110 EXEFL 21111 EXEFL 22111 EXEFL 23111 EXEFL 24111
Ex d IIB T6 IP66220 EXEFL 21211 EXEFL 22211 EXEFL 23211 EXEFL 24211
18W×2110 EXEFL 21112 EXEFL 22112 EXEFL 23112 EXEFL 24112
220 EXEFL 21212 EXEFL 22212 EXEFL 23212 EXEFL 24212
18W×1110 EXEFL 21111-H EXEFL 22111-H EXEFL 23111-H EXEFL 24111-H
Ex d IIC T6220 EXEFL 21211-H EXEFL 22211-H EXEFL 23211-H EXEFL 24211-H
18W×2110 EXEFL 21112-H EXEFL 22112-H EXEFL 23112-H EXEFL 24112-H
220 EXEFL 21212-H EXEFL 22212-H EXEFL 23212-H EXEFL 24212-H
32W×1110 EXEFL 21131 EXEFL 22131 EXEFL 23131 EXEFL 24131
Ex d IIB T6220 EXEFL 21231 EXEFL 22231 EXEFL 23231 EXEFL 24231
32W×2110 EXEFL 21132 EXEFL 22132 EXEFL 23132 EXEFL 24132
220 EXEFL 21232 EXEFL 22232 EXEFL 23232 EXEFL 24232
32W×1110 EXEFL 21131-H EXEFL 22131-H EXEFL 23131-H EXEFL 24131-H
Ex d IIC T6220 EXEFL 21231-H EXEFL 22231-H EXEFL 23231-H EXEFL 24231-H
32W×2110 EXEFL 21132-H EXEFL 22132-H EXEFL 23132-H EXEFL 24132-H
220 EXEFL 21232-H EXEFL 22232-H EXEFL 23232-H EXEFL 24232-H
Ordering Information
E X F L 2 1 1 2 3 - H ① ② ③ ④ ⑤ ⑥ ⑦
Lighting Fixture Type① Ballast Type② Mounting Type③
EXFL - Flameproof Fluorescent Lighting Fixture 2 - Internal Ballast 1 - Pendant
EXEFL - Emergency Fluorescent Lighting Fixture 2 - Ceiling
3 - 90° Bracket
4 - 40° Bracket
Voltage (V)④ Lamp Wattage (W)⑤ Quantity of ⑥ Lamp Option⑦
1 - 110 1 - 18 1 - ×1 None : IIB Type
2 - 220 2 - 20 2 - ×2 - H : IIC Type
3 - 230 3 - 32
4 - 240 4 - 40
5 - 36
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Anglecd/1000 lm
Anglecd/1000 lm
Blue Red Blue Red<EXFL 22152> 0 201.3 201.3 50 160.0 116.3
5 201.3 195.0 55 146.3 101.3Lamp : FL36×2+
(2×2500 lm)
With Globe and Guard+
10 201.3 192.5 60 135.0 83.8
15 200.0 188.8 65 128.8 65.0
20 191.3 182.5 70 123.8 47.5
25 185.0 175.0 75 110.0 30.0
30 180.0 166.3 80 82.5 16.3right picture explanation☞
Blue : Normal to Lamp+
Red : Parallel to Lamp+
35 175.0 156.3 85 68.8 7.5
40 170.0 143.8 90 50.0 2.5
45 165.0 131.3
Dimension
< EXEFL > < Pendant Type >
< 40° Bracket Type > < 90° Bracket Type > < Ceiling Type >
< EXFL > < Pendant Type >
< 40° Bracket Type > < 90° Bracket Type > < Ceiling Type >
SECTION - 4L
Flood Lighting Fixture
SECTION 4L
Flood Lighting Fixtures INDEX
Model
Lamp Type / Watt.Certification for
Explosion-proof
PAGEHigh Pressure Sodium Metal Halide Mercury
IEC
150 200 250 400 175 250 400 200 250 400
SGFD ● ● ● ● ● ● ● ● ● ● Ex nR II T3 4L - 1
EXFD ● ● ● ● ● ● ● ● ● ● Ex d B T3Ⅱ 4L - 3
VQFD ● ● ● ● ● ● ● ● ● ● Ex nR T3 IP66Ⅱ 4L - 5
EGFD ● ● ● ● ● ● ● ● ● ● Ex d C T4Ⅱ 4L - 7·
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Flood Lighting Fixtures
SGFD Series
Wet Locations
NEMA 3, 3R, 4, 4X, 7
Type of Explosion-proof
Non Sparking (Ex nR II T3)
Application Features Standard Materials
SGFD Series flood lighting fixtures
are used ;
in hazardous areas, both indoors
and outdoors where long life and
low maintenance costs are
desired.
in marine applications where
water spray and corrosive.
atmospheres are considerations
in petroleum refineries, chemical,
petrochemical and other heavy
process industry facilities.
in heavy process industries
having environments where
flammable or explosive vapors or
gases, or where combustible
dusts are present.
The body and mounting box are
wired with flameproof SPFC
flexible coupling.
The body is one piece casting
and the front flame incorporated
with front glass and guard is
hinged and fixed to the front of
the body.
The ballast is high quality one
maintaining much safety on
strength of enclosure.
The mounting box has a turning
base plate on the top and a
large access cover for wiring on
the side.
Main Body & Reflector:
Aluminum sheet
Front Frame :
Cast aluminium alloy
Front Glass :
Tempered plate glass
Ballast Housing : Steel
Wiring Tube :
SPFC Flexible coupling
Cradle : Steel
Mounting Box : Cast aluminium
alloy
<SGFD>
Certification
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Compliance
IEC 60079-0, 15
NEMA 3, 3R, 4, 4X, 7
IP55
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Projection Angle Adjustment Technical Data
Vertical 60° up down Electrical RatingsHorizontal 60° right and left
Rated VoltageAC110V/ 220V/ 240V
( See Below)※
Rated Wattage 150W/ 175W/ 200W/ 250W/ 400W
Rated Frequency 50Hz/ 60Hz WeightEntry Sizes 1/2", 3/4", 1"
Catalog No. WeightAlso you can order various voltage : ※
120V/ 208V/ 277V/ 460VSGNFD 66040 31.5 Kg
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number Ordering Information
Lamp Watt Ordering No. Certification S G N F D 6 6 0 1 5 ① ② ③
High
Pressure
Sodium
150 SGNFD 66015
Ex nR II T3
SGFD Flood Lighting Fixture① 200 SGNFD 66020
- SGMFD - Mercury Vapour
250 SGNFD 66025 - SGNFD - High Pressure Sodium
- SGHFD - Metal Halide400 SGNFD 66040
Metal
Halide
175 SGHFD 67017 : ② Lamp Type : Lamp Wattage (W)③
650 - Mercury Vapour 15 - 150250 SGHFD 67025 660 - H.P. Sodium 17 - 175
400 SGHFD 67040 670 - Metal Halide 20 - 200
Mercury
Vapor
200 SGMFD 65020 25 - 250
40 - 400250 SGMFD 65025
400 SGMFD 65040
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<SGNFD 66025> 0 355.0 50 45.0
5 180.0 55 30.0Lamp : High pressure sodium +
250W
Bare lamp Lumen : 25000 lm+
Reflector : aluminum reflector+
10 142.5 60 20.0
15 135.0 65 12.5
20 135.0 70 7.5
25 132.5 75 2.5
30 122.5 80 0.0
35 120.0 85 0.0
40 107.5 90 0.0
45 75.0
Dimension
< SGFD >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Flood Lighting Fixtures
EXFD Series
Wet Locations
NEMA 3, 3R, 4, 4X, 7
Type of Explosion-proof
<EXFD>
Flameproof (Ex d IIB T3)
Application
EXFD Series flood lighting fixtures are used ;
in hazardous areas, both indoors and outdoors
where long life and low maintenance costs are
desired.
in marine applications where water spray and
corrosive atmospheres are considerations.
in petroleum refineries, chemical, petrochemical
and other heavy process industry facilities.
in heavy process industries having environments
where flammable or explosive vapors or gases, or
where combustible dusts are present.
Features
The body and mounting box are wired with flame-
proof EFCX flexible coupling.
The body is one piece casting and the front flame
incorporated with front glass and guard is hinged
and fixed to the front of the body.
The ballast is high quality one maintaining much
safety on strength of enclosure.
The mounting box has a turning base plate on the
top and a large access cover for wiring on the
side.
Standard Materials Certification Compliance
Enclosure : Cast aluminium alloy
Globe : Heat resistant hard glass
Reflector : High purity aluminium
Guard : Stainless steel
Ballast Housing : Steel
Mounting Box : Cast aluminium
alloy
Wiring Tube : EFCX Flexible coupling
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas
Safety Corporation), and the
others.
IEC 60079-0, 1
NEMA 3, 3R, 4, 4X, 7
IP 55
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Technical Data WeightElectrical Rating Catalog No. Weight
Rated Voltage AC110V/ 220V/ 240V ( See Below)※ EXNFD 43040 45.4 ㎏
Rated Wattage 150W/ 175W/ 200W/ 250W/ 400W
Rated Frequency 50Hz/ 60Hz Projection Angle AdjustmentEntry Size 1/2", 3/4", 1" Vertical 35° up, 45°down
Also you can order various voltage : ※
120V/ 208V/ 277V/ 460V
Horizontal 60° right and left
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number Ordering Information
Lamp Watt Ordering No. Certification E X N F D 4 3 0 1 5 ① ② ③
High
Pressure
Sodium
150 EXNFD 43015
Ex d IIB T3
EXFD Flood Lighting Fixture① 200 EXNFD 43020
- EXMFD - Mercury Vapour
250 EXNFD 43025 - EXNFD - High Pressure Sodium
- EXHFD - Metal Halide400 EXNFD 43040
Metal
Halide
175 EXHFD 44017
Ex d IIB T2
: ② Lamp Type : Lamp Wattage (W)③
420 - Mercury Vapour 15 - 150250 EXHFD 44025
430 - H.P. Sodium 17 - 175400 EXHFD 44040
440 - Metal Halide 20 - 200
Mercury
Vapor
200 EXMFD 42020
Ex d IIB T3
25 - 250
40 - 400250 EXMFD 42025
400 EXMFD 42040
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<EXNFD 43025> 0 1657.5 50 15.0
5 862.5 55 5.0Lamp : High pressure sodium +
250W
Bare lamp Lumen : 25000 lm+
Reflector : aluminum reflector+
10 390.0 60 5.0
15 252.5 65 2.5
20 225.0 70 2.5
25 187.5 75 2.5
30 152.5 80 0.0
35 125.0 85 0.0
40 72.5 90 0.0
45 42.5
Dimension
< EXFD >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Flood Lighting Fixtures
VQFD/VRFD Series
Wet Locations
NEMA 3, 3R, 4, 4X, 7
Type of Explosion-proof
<VRFD> <VQFD>
Non Sparking (Ex nR II T3 IP66)
Application
VQFD Series flood lighting fixtures are used ;
at refineries, chemical, pharmaceutical and
petrochemical plants, waste and sewage treatment
plants, pulp and paper mills and other industrial
facilities containing hazardous (classified) areas.
at light process areas, storage tank and rack areas,
loading docks, rail yards, building perimeters, parking
areas, vehicle and pedestrian passageways and even
sports applications.
for security and safety lighting in industrial and process
facilities.
In industrial locations where the damaging effects of
rain, snow, wind, moisture, dirt, corrosion, vibration and
rough usage may be a problem.
to produce superior light at low cost with great
efficiency.
Accessories
Accessories
<CAM> <PWM> <SFM>
Crossarm
Mounting
Bracket
Pipe or Wall
Mounting
Bracket
Slip-Fitter
Features
Heavy duty copper free aluminum housing with epoxy
powder coat finish.
Unique 3 piece housing design.
Prewired with 3 ft. of 14/3 SO cord.
Required only two bolts to joint.
Easily adjustable to aim light where desired.
Heat and impact resistant tempered glass lens.
Heavy duty neoprene gasketing.
Anodized precision formed aluminum reflector.
NEMA 7x6 beam spread for light pattern.
Removable top plate provides easy access to lamp
compartment.
Weight
Catalog No. Weight
VQNFD 88040 27 Kg
Certification
Certified by KOSHA (Korea Occupational Safety &
Health Agency), KGS (Korea Gas Safety Corporation),
and the others.
Ballast
Standard : High efficient factor
Choke + ignitor typeStandard Materials Lamp
Housing : Cast aluminum alloy
External hardware : stainless steel
Yoke : Steel
Lens : Heat and impact resistant
tempered glass
Gasket : neoprene
Reflector : Semi-matt
HID Lamp Standard Finish
Aluminum : Epoxy powder coat
Steel (Yoke) : Hot dipped
galvanized
Stainless Steel : Natural
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Compliance
NEMA 3 ,3R, 4, 4X, 7
IEC 60079-0, 15
IP66
Technical DataOptionsAlso you can※
order various
voltage :
120V/ 208V/
277V/ 460V
Electrical RatingBody & Cover : Pure aluminium
sheet
Constant Wattage Auto
transformer Rated Voltage
Rated Voltage AC110V/ 220V/ 240V ( See Right)※
Rated Wattage 150W/ 175W/ 200W/ 250W/ 400W
Entry Size 1/2", 3/4", 1"
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number Ordering Information
Lamp Watt Ordering No. Certification V Q N F D 8 6 0 1 5 ① ② ③
High
Pressure
Sodium
150 VQNFD 86015
Ex nR II T3 IP66
Flood Lighting Fixture① 200 VQNFD 86020
- VQ - Ballast Box Separate Type
250 VQNFD 86025 - VR - Ballast Box Unite Type
: ② Lamp Type400 VQNFD 86040
MFD 850 - Mercury Vapour
Metal
Halide
175 VQHFD 87017 NFD 860 - H.P. Sodium
HFD 870 - Metal Halide250 VQHFD 87025
: Lamp Wattage (W)③ 400 VQHFD 87040
15 - 150
Mercury
Vapor
200 VQMFD 85020 17 - 175
20 - 200250 VQMFD 85025
25 - 250
400 VQMFD 85040 40 - 400
Photometric Data
0 -180 (Blue)˚ ˚ 90 -270 (Red)˚ ˚
Angle cd/1000 lm Angle cd/1000 lm
0 291.3 0 291.3<VQNFD 86040>10 300.0 10 258.8
Lamp : NH400 (50000 lm)+
With Globe and without Guard+ 20 303.8 20 220.0
30 240.0 30 187.5
40 165.0 40 177.5
50 120.0 50 125.0
60 75.0 60 23.8
right picture explanation☞
Blue : Normal to Lamp+
Red : Parallel to Lamp+
70 45.0 70 10.0
80 12.5 80 5.0
90 1.3 90 1.3
Dimension
< VRFD > < VQFD >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Flood Lighting Fixtures
EGFD Series
Wet Locations
NEMA 3, 3R, 4, 4X, 7
Type of Explosion-proof
<EGFD>
Flameproof (Ex d IIC T4 IP66)
Dust Ignition-proof (Ex DP II 12)
Application
EGFD Series flood lighting fixtures are used ;in heavy process industries having environments where flammable or explosive vapors or gases, or where combustible dusts are present.in hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired.in petroleum refineries, chemical, petrochemical and other heavy process industry facilities. in hazardous locations requiring elevated ambient capability.For mounting to a wall or structure.in mounted on a pole, when used with the SFM slipfitter adapter.
Features Standard Finish Standard Materials
Luminaire is factory wired; power
is fed through "wireless"
connection block which serves as
a mechanical seal between
conduit and ballast
compartments, eliminating the
need for an external, field
installed seal. The result is fast,
easy installation.
High bay reflectors of aluminium.
Internally fluted glass globes
reduce glare and provide
comfortable viewing light.
High power factor (90%+)
ballasts reduce power costs -
allow more luminaires per circuit.
Integral ballasts - separate
ballasts are not required. Lowest
installation cost.
Factory sealed, porcelain, mogul
base socket.
The turning arm gives you the
ability to offer a Hazard Gard
floodlight with varying degrees of
adjustability between -90 and ˚
+90 .˚
When mounting on a wall, there
are numerous mounting
arrangements -due to the
pre-drilled openings in the wall
bracket.
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Mounting module, cover, ballast
housing, guard, globe ring : Cast
aluminium alloy
Globe : heat and impact
resistant glass
Exterior hardware : stainless steel
Lamp socket : porcelain with
stainless steel screw shell
Reflector : high bay aluminium
Compliance
IEC 60079-0, 1
NEMA 3, 3R, 4, 4X, 7
Certification
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Weight
Catalog No. Weight
EGNFD 53040 32.5 ㎏
Technical Data
Electrical Rating
Rated Voltage AC110V/ 220V/ 240V ( See Below)※
Rated Wattage 150W/ 175W/ 200W/ 250W/ 400W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
Also you can order various voltage : ※
120V/ 208V/ 277V/ 460V
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number Ordering Information
Lamp Watt Ordering No. Certification E G N F D 5 3 0 1 5 ① ② ③
High
Pressure
Sodium
150 EGNFD 53015
Ex d IIC T4
Ex DP II 11
EGFD Flood Lighting Fixture① 200 EGNFD 53020
- EGMFD - Mercury Vapour
250 EGNFD 53025 - EGNFD - High Pressure Sodium
- EGHFD - Metal Halide400 EGNFD 53040 Ex d IIC T3
Metal
Halide
175 EGHFD 54017 Ex d IIC T4
Ex DP II 11
: ② Lamp Type : Lamp Wattage (W)③
520 - Mercury Vapour 15 - 150250 EGHFD 54025
530 - H.P. Sodium 17 - 175400 EGHFD 54040 Ex d IIC T3
Ex DP II 12 540 - Metal Halide 20 - 200
Mercury
Vapor
200 EGMFD 52020 Ex d IIC T4
Ex DP II 11
25 - 250
40 - 400250 EGMFD 52025
400 EGMFD 52040 Ex d IIC T3
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
0 1370.2 50 74.5<EGNFD 53025>5 1153.8 55 36.1
Lamp : High pressure sodium +
250W
Bare lamp Lumen : 26000lm+
Reflector : Flood type +
aluminum reflector
10 769.2 60 14.4
15 459.1 65 7.2
20 288.5 70 2.4
25 199.5 75 2.4
30 149.0 80 1.7
35 122.6 85 1.2
40 105.8 90 0.5
45 93.8
Dimension
< EGFD >
SECTION - 5L
Special Lighting Fixture
SECTION 5L
Special Lighting Fixtures INDEX
Model
Lamp Type / Watt.
Certification for
Explosion-proof
PAGE
Incandescent HalogenCompact
Fluorescent
100 200 500 25 40 60 350 20 IEC
ETL ● ● ● ● ● Ex d B T4 HⅡ 2 IP66 5L - 1
EHDL
57/58● ● ● Ex d C T3Ⅱ 5L - 3
EHDL 55 ● Ex d B T3Ⅱ 5L - 4
WOL ● 2 ●
Ex e Ⅱ T1
Ex de CⅡ T3
Ex nR II T4
5L - 5
UWLF Underwater Lighting Fixture 5L - 6
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Tank Inspection Lighting Fixtures
ETL Series
<ETL-H>
Type of Explosion-proof Flameproof (Ex d IIB T4 H2 IP66)
Application
ETL Series Tank lighting fixtures are used ;in illuminating stirred tank or storage tank, reactors, distillation columns, pipeline flow indicator etc.in petroleum refineries, chemical, petrochemical and other heavy process industry facilities. where an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only.
Features Standard Materials
The metal casing is composed of three part; body, front frame and terminal box.Fixing of the fittings are to be done by suitable mounting hardwares utilizing the mounting base on the front frame.Terminal is fitted to the body with spigot joint and being secured by three set crews.Easy installation and maintenance.220V power supply directly.Also can supply 110V, 240V (ordered).Incandescent lamp 100W, 200W.
Also have Halogen Lamp 25W, 40W, 60W.
Housing, mounting modules, component pallets :
Cast aluminium alloy
Front Glass : Tempered plate glass
Inner Reflector : High purity aluminium
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Technical Data
Catalog No. ETL 4101 ETL 4102 ETL 4201 ETL-H 5101 ETL-H 5102 ETL-H 5103
Rated Voltage (V) 220 220 220 110/220 110/220/240 110/220/240
Rated Wattage (W) 100 200 100 25 40 60
Lamp Incandescent Incandescent Incandescent Halogen Halogen Halogen
Weight (kg) 2.8 4.8 2.0 2.9 2.9 2.9
Classification of
Explosion-proofEx d IIB T3 Ex d IIB T2 Ex d IIB T3
Ex d IIB T4 H2
IP66Ex d IIB T3 H2 Ex d IIB T3 H2
<ETL-H> <ETL4101> <ETL4102>
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm<ETL 4102> 0 109.2 50 47.1
5 117.7 55 38.5Lamp : IL200(2920 lm)+ 10 115.6 60 30.0
15 113.5 65 21.4
20 109.2 70 12.8
25 104.9 75 6.4
30 96.3 80 2.2
35 77.1 85 0
40 79.2 90 0
45 57.8
Angle cd/1000 lm Angle cd/1000 lm<ETL-H 5103> 0 442.1 50 30.5
5 503.0 55 0Lamp : +
HALOGEN60(820 lm) 10 426.8 60 0
15 297.3 65 0
20 198.2 70 0
25 152.4 75 0
30 152.4 80 0
35 129.6 85 0
40 91.5 90 0
45 61.0
Dimension
<ETL-H> <ETL 4101> <ETL 4102>
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent / Compact Fluorescent
Portable Hand Lamp
EHDL 57/58 Series
<EHDL 57>
Type of Explosion-proof
Flameproof (Ex d IIC T3)
Application
EHDL Series portable handlamps are used ;
as portable handlamp in hazardous area.
in inspecting aircraft wing tanks, vats, process
vessels, fuel tanks, etc.
Features
The metal casing consists of a body, globe holder
and terminal box, and provides a flameproof cable
gland at the top of the terminal box.
The globe holder firmly attached with globe and
guard is screwed onto the body and locked by one
socket head screw.
Choose incandescent lamp/compact fluorescent lamp.
Standard Materials Compliance
Body : Cast aluminium alloy
Globe : Heat-resistant hard glass
Handle : PVC
IEC 60079-0, 1
CertificationStandard Finish Certified by KOSHA (Korea Occupational Safety &
Health Agency), KGS(Korea Gas Safety Corporation),
and the others.MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Technical Data
Catalog No. Rated Voltage(V) Rated Wattage (W) Lamp Weight (kg) Certification
EHDL 57 Max. 230 100 Incandescent 2.5 Ex d IIC T3
EHDL 58F Max. 230 20 Compact Fluorescent 2.7 Ex d IIC T6
Photometric Data Dimension
Angle EHDL 57 EHDL 58F Angle EHDL 57 EHDL 58F
0 90.0 22.7 50 85.0 68.2
5 75.0 22.7 55 85.0 73.9
10 75.0 28.5 60 90.0 79.5
15 90.0 28.5 65 105.0 79.5
20 80.0 34.1 70 90.0 85.3
25 75.0 34.1 75 85.0 85.3
30 80.0 45.5 80 85.0 85.3
35 85.0 51.2 85 85.0 85.3
40 85.0 56.8 90 80.0 85.3
45 95.0 62.5 cd/1000 lm
Blue = Incandescent Lamp 100W (1250 lm)
Red = Compact Fluorescent Lamp 20W (1200 lm)
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent Portable Hand Lamp
EHDL 55
<EHDL 55>
Type of Explosion-proof
Flameproof (Ex d IIB T3)
Application
EHDL Series portable handlamps are used ;
as a portable handlamp in hazardous area.
where an explosive atmosphere consisting of a
mixture with air of flammable substances in the form
of gas, vapour or mist is not likely to occur in
normal operation but, if it does occur, will persist for
a short period only.
in inspecting aircraft wing tanks, vats, process
vessels, fuel tanks, etc.
Standard Materials Features
Body : Cast aluminium alloy
Globe : Heat-resistant hard glass
Guard : Stainless steel
The metal casing consists of a body, globe holder
and terminal box, and provides a flameproof cable
gland at the top of the terminal box.
The globe holder firmly attached with globe and
guard is screwed onto the body and locked by one
socket head screw.
The terminal box is fitted to the body with spigot
joint and is secured by two socket head screws.
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Technical Data
Catalog No. Rated Voltage (V) Rated Wattage (W) Lamp Weight (kg) Certification
EHDL 5501 110/220 100 Incandescent 2.8 Ex d IIB T3
Dimension
Angle cd/1000 lm Angle cd/1000 lm
0 35.0 50 35.0
5 25.0 55 45.0
10 25.0 60 50.0
15 30.0 65 50.0
20 40.0 70 55.0
25 40.0 75 55.0
30 40.0 80 50.0
35 45.0 85 45.0
40 45.0 90 20.0
45 35.0
<EHDL 5501>
[Lamp : IL100] [1×1250 lm]
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Obstruction Lighting Fixtures
WOL Series
Type of Explosion-proof
<502> <200,000 cd> <SWOL101>
<EWOL 101>
Flameproof-Increase Safety (Ex de IIC T4)
Increase Safety (Ex e II T1)
Non sparking (Ex nR II T4)
Application
WOL Series Obstruction lighting fixtures are used ;
in petroleum refineries, chemical, petrochemical and
other heavy process industry facilities.
where an explosive atmosphere consisting of a
mixture with air of flammable substances in the form
of gas, vapour or mist is not likely to occur in
normal operation but, if it does occur, will persist for
a short period only.
Features Standard Materials
Easy installation and maintenance.
220V power supply directly.
Also can supply 110V, 240V (ordered).
Standard type is Increase Safety. can order made
Flameproof-Increase Safety type
Housing : Cast aluminium alloy
Globe : Heat resistant hard glass
Mounting Box : Cast aluminium alloy
Standard FinishNavigation Red
If you want another color, contact us
please.
Technical Data
Catalog No. SWOL 101 SWOL 502 SWOL 200,000cd EWOL 101 EWOL 502
Rated Voltage (V) 110/ 220 110/ 220 220 110/220 110/220
Rated Wattage (W) 100W ×1 500W ×2 350W 100W 500W ×2
Lamp Incandescent Incandescent Xenon Incandescent Incandescent
Weight (kg) 5.8 Kg 53 Kg 21 Kg 5.8 Kg 53 Kg
Classification of
Explosion-proofEx e II T1 Ex e II T1 Ex e II T4 Ex d IIB T4 Ex de IIC T3
Dimension
< 200,000cd >
< 502 >
< SWOL101 >
< EWOL 101 >
If you need more information, contact us please. ⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Underwater Lighting Fixture
UWL SeriesNuclear containment-grade materials
General InformationThe NAMBUK underwater lighting fixture model UWL
series are designed for underwater use in nuclear
plant fuel pool.
While widely used as a general area lighting fixture
in new and spent fuel pools, it is also used for
localized inspection and for in-core use during refuel
operations, etc.
<UWLF>
Features
<LP-P>
Brilliant illumination, with two sealed beam lamp
Easy maintenance.
All stainless steel "inside-containment" construction
Integral underwater connectors, designed for easy
operation
With pin type lamp (LP-P) or socket type lamp
(LP-S)
Lamp & Base
<LP-S>
PAR 64 Sealed Beam Lamp
Beam Angle : Wide(Standard), Midium, Narrow
LP-P : 120V, 1000W, Pin Type Base
LP-S : 120V, 1000W, E39 Socket Type Base
<FUW>
Standard Materials Body : 304 Stainless steel
Bracket : 304 Stainless steel
Cable : SOOW (Other cables are order made)
Standard FinishNatural
Technical Data
Model No. Voltage (V) Wattage (W) Lamp Base
UWLF 1000 Max. 120 2 × 1000W Sealed Beam Pin Type
UWLS 1000 Max. 120 2 × 1000W Sealed Beam E39 Socket Type
Dimension
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2011
Obstruction Lighting Fixtures
EWOL Series
Panel for Obstruction Lighting
OLCP Series
Type of Explosion-proof
<EWOL-AB-LE> <EWOL-AB-XL> <EWOL-AB-LE>
Flameproof (Ex d IIB T6 IP66)
Flameproof (Ex d IIC T6 IP66)
Dust Protection (Ex tD A21 IP66 T85℃)
Application
WOL Series Obstruction lighting fixtures are used ;
in petroleum refineries, chemical, petrochemical
and other heavy process industry facilities.
where an explosive atmosphere consisting of a
mixture with air of flammable substances in the
form of gas, vapour or mist is not likely to
occur in normal operation but, if it does occur,
will persist for a short period only.
Features Standard Materials
Easy installation and maintenance.
240VAC/24VDC power supply directly.
Others voltage is order made.
Housing : Cast aluminium alloy
Globe : Heat resistant hard glass
Mounting Box : Cast aluminium alloy
Standard Finish
Navigation Red
If you want another color, contact us please.
Compliance CertificationIEC/EN 60079-0, 1
IEC/EN 61241-0, 1
ICAO Standard
IP 66
INERIS 11 ATEX 0039X by INERIS (EWOL-AB-LE)
INERIS 11 ATEX 0037X by INERIS (EWOL-AB-XL)
INERIS 11 ATEX 0040X by INERIS (OLCP-XL)
INERIS 11 ATEX 0038X by INERIS (OLCP-LE)
IECEx KTL 11.0007X by KTL (EWOL-AB-LE)
IECEx KTL 11.0009X by KTL (EWOL-AB-XL)
IECEx KTL 11.0010 by KTL (OLCP-XL)
IECEx KTL 11.0008 by KTL (OLCP-LE)
IECEx KTL 11.0011X by KTL (EWOL-L-LE)
Technical Data
Catalog No. EWOL-AB-XL EWOL-AB-LE EWOL-L-LE
Rated Voltage (V) Max. 240V DC 24V 220V
Rated Wattage (W) 100W × 2 100W 12W
Lamp Xenon LED LED
Light IntensityWhite 20,000 cd
200 cdRed 2,000 cd
Flashing Frequency 20 ~ 60 fpm Fixed
Ambient Temperature -20℃ ~ 55℃
Weight (kg) 54 Kg 58 Kg 5.8 Kg
Classification of
Explosion-proof
Ex d IIB T6
Ex tD A21 IP66 T85℃
Ex d IIB T6
Ex tD A21 IP66 T85℃
Ex d IIC T6
Ex tD A21 IP66 T85℃
⇨ If you need more information, contact us please.
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2011
Dimension
<EWOL-AB-XL>
<EWOL-AB-LE>
<EWOL-L-LE>
<OLCP-XL>
<OLCP-LE>
⇨ If you need more information, contact us please.
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2011
Street Lighting Fixtures
HA-L-B Series
Features Standard Materials
H.I.D lighting fixture has internal type ballast.
This type is designed to be suitable for mounting
arm of 55~63mm OD
Body : Die casting aluminium
Globe : Heat resistant hard glass
Inner Reflector : Aluminium
Standard Finish Certification
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Certified by CE
Compliance
IP65
Technical Data
Electrical Ratings
Rated Voltage AC110V/ 220V/ 230V/ 240V
Rated Wattage 150W/ 175W/ 200W / 250W
Rated Frequency 50Hz/ 60Hz
※ Also you can order various voltage :
120V/ 208V/ 277V/ 460V
Ordering Number Dimension
Lamp Watt Catalog No.
High
Pressure
Sodium
150 HANL 150B
200 HANL 200B
250 HANL 250B
Metal
Halide
175 HAHL 175B
250 HAHL 250B
Mercury
Vapor
200 HAML 200B
250 HAML 250B
⇨ If you need more information, contact us please.
℃
M
Angle Lux C.P Angle Lux C.P Angle Lux C.P Angle Lux C.P0 390 2,437.5 0 390 2,437.5 0 390 2,437.5 0 390 2,437.5
5 391 2,443.8 5 391 2,443.8 5 415 2,593.8 5 391 2,443.8
10 388 2,425.0 10 388 2,425.0 10 425 2,656.3 10 362 2,262.5
15 385 2,406.3 15 385 2,406.3 15 460 2,875.0 15 335 2,093.8
20 471 2,943.8 20 471 2,943.8 20 625 3,906.3 20 271 1,693.8
25 536 3,350.0 25 536 3,350.0 25 665 4,156.3 25 215 1,343.8
30 586 3,662.5 30 586 3,662.5 30 530 3,312.5 30 200 1,250.0
35 689 4,306.3 35 689 4,306.3 35 412 2,575.0 35 165 1,031.3
40 765 4,781.3 40 765 4,781.3 40 350 2,187.5 40 135 843.8
45 799 4,993.8 45 799 4,993.8 45 320 2,000.0 45 118 737.5
50 680 4,250.0 50 680 4,250.0 50 295 1,843.8 50 105 656.3
55 501 3,131.3 55 501 3,131.3 55 225 1,406.3 55 95 593.8
60 360 2,250.0 60 360 2,250.0 60 168 1,050.0 60 75 468.8
65 245 1,531.3 65 245 1,531.3 65 155 968.8 65 51 318.8
70 168 1,050.0 70 168 1,050.0 70 115 718.8 70 35 218.8
75 135 843.8 75 135 843.8 75 75 468.8 75 25 156.3
80 85 531.3 80 85 531.3 80 65 406.3 80 15 93.8
85 62 387.5 85 62 387.5 85 25 156.3 85 12 75.0
90 25 156.3 90 25 156.3 90 15 93.8 90 8 50.0
NAM BUK ELECTRIC Co., LTD.
A, C B, D
SYMMETRY(0-A, CW) SYMMETRY(0-B, CCW) ASYMMETRY(0-C, CW) ASYMMETRY(0-D, CCW)
REMARK AD CB
HA – L – B (신형가로등) NH150W 사용UL 인증예정품
* C.P : Lux * (DISTANCE)2
STANDARD LAMP NH150 / 14000Lm DISTANCE 2.5
INSPECTOR CHA.Y.H D A T E 2012년 2월 6일
PHOTOMETRIC DATA
I T E M HA-L-B MODEL No.
S I Z E AC220V/60Hz Tamb. 10
℃
M
Angle Lux C.P Angle Lux C.P Angle Lux C.P Angle Lux C.P0 758 4,737.5 0 758 4,737.5 0 758 4,737.5 0 758 4,737.5
5 762 4,762.5 5 762 4,762.5 5 762 4,762.5 5 742 4,637.5
10 721 4,506.3 10 721 4,506.3 10 792 4,950.0 10 725 4,531.3
15 718 4,487.5 15 718 4,487.5 15 835 5,218.8 15 579 3,618.8
20 748 4,675.0 20 748 4,675.0 20 945 5,906.3 20 510 3,187.5
25 768 4,800.0 25 768 4,800.0 25 1,042 6,512.5 25 410 2,562.5
30 815 5,093.8 30 815 5,093.8 30 780 4,875.0 30 365 2,281.3
35 905 5,656.3 35 905 5,656.3 35 685 4,281.3 35 289 1,806.3
40 1,052 6,575.0 40 1,052 6,575.0 40 602 3,762.5 40 241 1,506.3
45 1,225 7,656.3 45 1,225 7,656.3 45 542 3,387.5 45 182 1,137.5
50 1,100 6,875.0 50 1,100 6,875.0 50 385 2,406.3 50 156 975.0
55 901 5,631.3 55 901 5,631.3 55 312 1,950.0 55 115 718.8
60 712 4,450.0 60 712 4,450.0 60 255 1,593.8 60 85 531.3
65 472 2,950.0 65 472 2,950.0 65 185 1,156.3 65 68 425.0
70 251 1,568.8 70 251 1,568.8 70 125 781.3 70 52 325.0
75 165 1,031.3 75 165 1,031.3 75 75 468.8 75 31 193.8
80 75 468.8 80 75 468.8 80 52 325.0 80 21 131.3
85 56 350.0 85 56 350.0 85 32 200.0 85 15 93.8
90 25 156.3 90 25 156.3 90 12 75.0 90 6 37.5
NAM BUK ELECTRIC Co., LTD.
A, C B, D
SYMMETRY(0-A, CW) SYMMETRY(0-B, CCW) ASYMMETRY(0-C, CW) ASYMMETRY(0-D, CCW)
REMARK AD CB
HA – L – B (신형가로등) NH-250 사용UL 인증예정품
* C.P : Lux * (DISTANCE)2
STANDARD LAMP NH 250 / 25000Lm DISTANCE 2.5
INSPECTOR CHA.Y.H D A T E 2012년 2월 6일
PHOTOMETRIC DATA
I T E M HA-L-B MODEL No.
S I Z E AC220V/60Hz Tamb. 10
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2011
LED Lighting Fixtures
ELE Series
with High Efficiency LED
New Product
Type of Explosion-proof
Flameproof (Ex d IIC T6 IP66)
Description
The explosion protected lighting fixtures for
Power LED light is in according to the
IEC60079-1, 0.
This product is certified for use in the Zone 1
and 2, made of aluminium alloy and
aluminium die casting with a powdered
coating.
Power LED lighting fixture is designed for
outdoor use.
Especially, It's for chemical factories, offshore
platforms and illuminating large areas.
Features Technical DataNew lighting source is Power LED 120W/135W
(12 PCB Modules)
Long life time ( 50000 hour in LED only )
Light on and light out immediately
Ambient temperature -20℃ to 40℃
Electrical Rating
Rated Voltage AC 220 VAC ~ 260 VAC
Input Wattage 135 W / 150W
Output Wattage 120 W / 135W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2" , 3/4" , 1" Compliance & Certification Weight 22kg ( Full set )IEC 60079-0, 1
Ex d IIC T6 IP66
Certitied by KOSHA ( Korea Occupational
Safety & Health Agency )
Standard MaterialsEnclosure: Aluminium Die-casting
Globe: Heat resistant hard glass
Guard: Stainless Steel
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please
Chromating Photometric Data
Angle C.P Angle C.P
<ELE 135> 0 3,531 50 2,256
5 3,475 55 1,963+Lamp : LED 135W
+With Globe 10 3,250 60 1,719
15 3,263 65 1,500
20 3,213 70 1,175
Lamp WattConversion
Factor25 3,206 75 719
30 3,067 80 406
120 0.75
35 3,019 85 156
40 2,969 90 44
45 2,631
⇨ If you need more information, contact us please.
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2011
Ordering Number
Lamp WattHub
SizePendant Ceiling Bracket Stanchion Certification
LED
120
1" ELE LE 1121 ELE LE 2121 ELE LE 3121 ELE LE 4121
Ex d IIC T6 IP66
3/4" ELE LE 1123 ELE LE 2123 ELE LE 3123 ELE LE 4123
1/2" ELE LE 1125 ELE LE 2125 ELE LE 3125 ELE LE 4125
135
1" ELE LE 1131 ELE LE 2131 ELE LE 3131 ELE LE 4131
3/4" ELE LE 1133 ELE LE 2133 ELE LE 3133 ELE LE 4133
1/2" ELE LE 1135 ELE LE 2135 ELE LE 3135 ELE LE 4135
Ordering Information
E LE LE 1 1 2 1 / 2 6 ① ② ③ ④ ⑤ ⑥
① ELE Lighting Fixture ⑤ Entry Size
1 - 1"
② Lamp Type 3 - 3/4"
LE - LED 5 - 1/2"
③ Mounting Type
1 - Pendant ⑥ Input Voltage (V)
2 - Ceiling 22 - 220V
3 - Bracket 24 - 240V
4 - Stanchion 25 - 250V
26 - 260V
④ Lamp Wattage (W)
12 -120W
13 -135W
Dimension
< 40° Bracket Type> < 90° Bracket Type > < Ceiling Type > < Pendant Type >
SECTION - 1C
Combination Station
SECTION 1C
Combination Station INDEX
Model Product DescriptionCertification for
Explosion-proofPAGE
ECS
Control unit combination
Rectangular Type
Ex d B T6Ⅱ
(EPB, ESS :
Class I Group C,D
Class II Group EFG)
1C - 3
ESCControl unit combination
Circular TypeEx d C T6 IP55Ⅱ 1C - 5
VGN Various Kind of control unit combination Vapor tight Type 1C - 7
VEGN Various Kind of control unit combination Ex de IIC T6 1C - 9
EGN Various Kind of control unit combination Ex d B T6Ⅱ 1C - 11
EFCS Engineering Plastic Combination Stations Ex de C T6 IP66Ⅱ 1C - 13
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Combination Switch
ECS, ESC Series
Wet Locations
NEMA 3,3R,4,4X,7,9
< ECS Series >
< ESC Series >
Application Features
Industrial areas such as chemical plants, oil and gas
refineries, paint and vanish manufacturing plants,
gasoline bulk loading terminals, grain elevators, grain
processing industries, coal processing or handling areas
where atmospheres may contain hazardous gases or
dusts and arcing of enclosed devices must not ignite
the surrounding atmosphere.
Controlling and supplying energy to portable electrical
devices such as motor generator sets, compressors,
conveyors, portable tools, etc.
These are the combinations of meters, pilot lights
(Single or double), Cam switches, Selector switches and
Push button switches (single or double), the main
enclosures of which are fitted to the terminal boxes of
two or three gangs.
This range of all units has complete interchangeability in
the joints between the main enclosures and the terminal
boxes, so that any combination is available. When a
combination other than listed in the tables is required,
specify the units to be combined.
The flameproof enclosure are composed of the main
body and cover with four hexagonal headed bolts.
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.Standard Materials
Terminal Box : Cast aluminum alloy
Main Enclosure : Die casting aluminium
Pole : Steel pipe
Base : Cast aluminium alloy
Option
Sunshade Cover
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Units Specification Electrical Ratings
Am-meter
Volt-meter
-The Am-meters and Volt-meters are moving iron instruments
with an accuracy class 1.5
-Standard overload scales are max.3 times
-On Am-meters for 1 and 5 Amp C.T connection
Pilot Lamp-The pilot system based on the use of luminescent diodes as
the lamp source.
LED : AC 110,220V/20mA max., DC24V
Filament Lamp : AC 110,220V/3W
Cam Switch
-Cam Switches max 4 positions are available with conventional
contactors or as a contact-free version.
-The contact arrangements can be selected, spring return or
notched positions can be supplied (refer to contact
arrangement on this page).
Contact Ratings
AC 110V 15Amp.
300V 10Amp.
440V 3Amp.
DC 24V 10Amp.
110V 5Amp.
220V 3Amp.
Selector
Switch
-Selector switches max 4 positions are available.
-The switching arrangements can be selected, spring return or
notched position are available.
AC 250V 5A Contact Rating.
Push Button
Switch
-The standard contact block is double pole, 1 NC (Normally
closed), and 1 NO (Normally Open contact)AC 250V 5A Contact Rating.
Suffix No.
For Operating Magnetic Motor Starter Suffix No.
For ON OFF or Selective Transfer Operation․
Handle Positions Contact Arrangements Handle
Positions Contact Arrangements
1 7
2 8
3 9
4 10
5 11
6 12
Explanation on Operating Diagrams in the TableIn the operating diagrams in the table above, the longitudinal dotted lines show the operating positions of switch, the small circles on the both ends of lateral line show the terminals, and the figures show the terminal numbers.The marks showing the conditions of contacts at each operating position are explained as follows:1. The contact between both terminals is closed at this position.● 2. The contact is closed successively between the two positions.3. The mark of residual contact. The contact is closed when the handle is set to this position and keeps closed ← ◉
after the handle returns. The contact is open at the fine point of the arrow mark when the handle is operated in this direction.
4. A The mark of spring return. The arrow mark shows the direction of automatic spring return form 'A' to the fine point of it.
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Rectangular Combination Switch
ECS Series
Wet Locations
NEMA 3,3R,4,4X,7,9
Type of Explosion-proof Rating : ◎ Max. 250 Volt, Max. 5 Ampere.
EPB Push button and ESS Selector S/W are
UL Listed.Flameproof (Ex d IIB T6)
Class I Group CD Class II Group EFG
1 Gang
No. of
Gangs
Unit Arrangement Catalog Number
MeterPilot Lamp Cam
Switch
Selector
Switch
Push ButtonWall Mounting Standing
Single Double Single Double
1 Gang
○ ECS 101 ECS 101T
○ ECS 102 ECS 102T
○ ECS 103 ECS 103T
○ ECS 104 ECS 104T
○ ECS 105 ECS 105T
○ ECS 106 ECS 106T
○ ECS 107 ECS 107T
2 Gang
No. of
Gangs
Unit Arrangement Catalog Number
MeterPilot Lamp Cam
Switch
Selector
Switch
Push Button Wall mounting Standing
Single Double Single Double Horizontal Vertical Vertical
2 Gang
○ ○ ECS 201 ECS 201V ECS 201T
○ ○ ECS 202 ECS 202V ECS 202T
○ ○ ECS 203 ECS 203V ECS 203T
○ ○ ECS 204 ECS 204V ECS 204T
○ ○ ECS 205 ECS 205V ECS 205T
○ ○ ECS 206 ECS 206V ECS 206T
○ ○ ECS 207 ECS 207V ECS 207T
○ ECS 208 ECS 208V ECS 208T
○○ ECS 209 ECS 209V ECS 209T
○ ○ ECS 210 ECS 210V ECS 210T
○ ○ ECS 211 ECS 211V ECS 211T
○ ○ ECS 212 ECS 212V ECS 212T
○○ ECS 213 ECS 213V ECS 213T
○ ECS 214 ECS 214V ECS 214T
○○ ECS 215 ECS 215V ECS 215T
Control
Copyright by NAMBUK Electric Co., LTD. 2004
3 Gang
3 Gang Horizontal Type
No. of
Gangs
Unit Arrangement Catalog Number
MeterPilot Lamp Cam
Switch
Selector
Switch
Push Button Wall mounting Standing
Single Double Single Double Horizontal Vertical Vertical
3 Gang
○ ○ ○ ECS 301 ECS 301V ECS 301T
○ ○ ○ ECS 302 ECS 302V ECS 302T
○ ○ ○ ECS 303 ECS 303V ECS 303T
○ ○ ○ ECS 304 ECS 304V ECS 304T
○ ○ ○ ECS 305 ECS 305V ECS 305T
○ ○ ○ ECS 306 ECS 306V ECS 306T
○ ○ ○ ECS 307 ECS 307V ECS 307T
○ ○ ○ ECS 308 ECS 308V ECS 308T
○ ○ ○ ECS 309 ECS 309V ECS 309T
○ ○ ○ ECS 310 ECS 310V ECS 310T
Standing Type
<2 Gang Vertical Type>
<3 Gang Vertical Type>
<4 Gang Type>
* ECS 4 Gang is order made.
Contact us please.
Ordering Information
E C S 2 1 4 T ① ② ③ ④
Flameproof ECS Combination Stations① Combination Type③
Gang number② Style Type④
100 Series : 1 Gang None : Wall Mounting Horizontal Type
200 Series : 2 Gang V : Wall Mounting Vertical Type
300 Series : 3 Gang T : Standing Vertical Type
400 Series : 4 Gang (Order made)
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Circular Combination Switch
ESC Series
Wet Locations
NEMA 3,3R,4,4X,7,9
Type of Explosion-proof Rating : ◎ Max. 250 Volt, Max. 5 Ampere.
Flameproof (Ex d IIC T6 IP55)
1 Gang
No. of
Gangs
Unit Arrangement Catalog Number
MeterPilot Lamp Cam
Switch
Selector
Switch
Push ButtonWall Mounting Standing Type
Single Double Single Double
1 Gang
○ ESC 101 ESC 101T
○ ESC 102 ESC 102T
○ ESC 103 ESC 103T
○ ESC 104 ESC 104T
○ ESC 105 ESC 105T
○ ESC 106 ESC 106T
○ ESC 107 ESC 107T
* Emergency Switch Unit and Buzzer Unit are order made.
2 Gang
No. ofGangs
Unit Arrangement Catalog Number
MeterPilot Lamp Cam
SwitchSelectorSwitch
Push Button Wall mounting Standing
Single Double Single Double Horizontal Vertical Vertical
2 Gang
○ ○ ESC 201 ESC 201V ESC 201T
○ ○ ESC 202 ESC 202V ESC 202T
○ ○ ESC 203 ESC 203V ESC 203T
○ ○ ESC 204 ESC 204V ESC 204T
○ ○ ESC 205 ESC 205V ESC 205T
○ ○ ESC 206 ESC 206V ESC 206T
○ ○ ESC 207 ESC 207V ESC 207T
○ ESC 208 ESC 208V ESC 208T
○○ ESC 209 ESC 209V ESC 209T
○ ○ ESC 210 ESC 210V ESC 210T
○ ○ ESC 211 ESC 211V ESC 211T
○ ○ ESC 212 ESC 212V ESC 212T
○○ ESC 213 ESC 213V ESC 213T
○ ESC 214 ESC 214V ESC 214T
○○ ESC 215 ESC 215V ESC 215T
* Emergency Switch Unit and Buzzer Unit are order made.
Control
Copyright by NAMBUK Electric Co., LTD. 2004
3 Gang
No. ofGangs
Unit Arrangement Catalog Number
MeterPilot Lamp Cam
SwitchSelectorSwitch
Push Button Wall mounting Standing
Single Double Single Double Horizontal Vertical Vertical
3 Gang
○ ○ ○ ESC 301 ESC 301V ESC 301T
○ ○ ○ ESC 302 ESC 302V ESC 302T
○ ○ ○ ○ ESC 303 ESC 303V ESC 303T
○ ○ ○ ESC 304 ESC 304V ESC 304T
○ ○ ○ ESC 305 ECS 305V ECS 305T
○ ○ ○ ESC 306 ESC 306V ESC 306T
○ ○ ○ ESC 307 ESC 307V ESC 307T
○ ○ ○ ESC 308 ESC 308V ESC 308T
○ ○ ○ ESC 309 ESC 309V ESC 309T
○ ○ ○ ESC 310 ESC 310V ESC 310T
* Emergency Switch Unit and Buzzer Unit are order made.
Standing Type
2 Gang Vertical Type
3 Gang Vertical Type
<4 Gang Type>
* ESC 4 Gang is order made.
Contact us please.
Ordering Information
E S C 2 1 4 V ① ② ③ ④
Flameproof ESC Combination Stations① Combination Type③
Gang number② Style Type④
100 Series : 1 Gang None : Wall Mounting Horizontal Type
200 Series : 2 Gang V : Wall Mounting Vertical Type
300 Series : 3 Gang T : Standing Vertical Type
400 Series : 4 Gang (Order made)
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Vaportight Combination Stations
VGN Series
Weatherproof Type
NEMA 3,3R,4,4X,7,9
Rating : ◎ Max. 250 Volt, Max. 5 Ampere.
Application Features
VGN Series combination stations are used in;
as enclosures for Combination motor starters or
integrated type combination line starters.
as control boxes or stands which incorporate various
control switches, pilot lamps, ampere or volt meters,
selector switches, push button switches.
indoor or outdoor areas.
The box body and cover are made of cast
aluminium alloy.
They are Combination design and have enough
mechanical strength.
The cover fixing bolts are made of stainless steel.
Light weight design for easy of installation and
maintenance.
The main body and cover are secured with stainless
steel bolts through a synthetic rubber gasket,
retaining high corrosion resistant and watertightness.
The conduit entries can be arranged in desired
positions.
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
VGN200
VGN400
2, 3 Gang
TYPESDimensions(mm)
A B
VGN200 160 200
VGN300 186 216
Control
Copyright by NAMBUK Electric Co., LTD. 2004
4, 5, 6 Gang
TYPESDimensions(mm)
A B
VGN400
VGN500
VGN600
210 250
8, 10, 12 Gang
TYPESDimensions(mm)
A B
VGN800
290 330VGN1000
VGN1200
Ordering Information
V G N 2 0 0 T ① ② ③
VGN Combination Stations① Style Type③
None : Wall Mounting Type
Gang number② T : Standing Type
200 Series = 2 Gang 600 Series = 6 Gang
300 Series = 3 Gang 800 Series = 8 Gang
400 Series = 4 Gang 1000 Series = 10 Gang
500 Series = 5 Gang 1200 Series = 12 Gang
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Combination Stations
VEGN Series
Wet Locations
NEMA 3,3R,4,4X,7,9
Rating : ◎ Max. 250 Volt, Max. 5 Ampere.
Type of Explosion-proof
Flameproof-Increase Safety (Ex de IIC T6)
Application Features
VEGN Series combination stations are used in;
as enclosures for Combination motor starters or
integrated type combination line starters.
as control boxes or stands which incorporate various
control switches, pilot lamps, ampere or volt meters,
selector switches, push button switches.
indoor or outdoor areas.
The box body and cover are made of cast
aluminium alloy.
They are Combination design and have enough
mechanical strength.
The cover fixing bolts are made of stainless steel.
Light weight design for easy of installation and
maintenance.
The main body and cover are secured with stainless
steel bolts through a synthetic rubber gasket,
retaining high corrosion resistant and watertightness.
The conduit entries can be arranged in desired
positions.
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
VEGN200
VEGN400
2, 3 Gang
TYPESDimensions(mm)
A B
VEGN200 160 200
VEGN300 210 250
Control
Copyright by NAMBUK Electric Co., LTD. 2004
4, 5, 6 Gang
TYPESDimensions(mm)
A B
VEGN400
VEGN500
VEGN600
210 250
8, 10, 12 Gang
TYPESDimensions(mm)
A B
VEGN800
290 330VEGN1000
VEGN1200
Ordering Information
V E G N 2 0 0 T ① ② ③
VEGN Combination Stations① Style Type③
None : Wall Mounting Type
Gang number ② T : Standing Type
200 Series : 2 Gang 600 Series : 6 Gang
300 Series : 3 Gang 800 Series : 8 Gang
400 Series : 4 Gang 1000 Series : 10 Gang
500 Series : 5 Gang 1200 Series : 12 Gang
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Combination Stations
EGN Series
Wet Locations
NEMA 3,3R,4,4X,7,9
Rating : ◎ Max. 250 Volt, Max. 5 Ampere.
Type of Explosion-proof Flameproof (Ex d IIB T6)
Features Standard Materials
EGN type control station can be easily disassemble
main box that is composed of explosion-proof
construction and various kind of control unit into
Terminal box, and also can be easily assemble.
We meet customer's requirement by manufacture two
type, bracket type and standing type,
explosion-proof control station unit.
Main box body : Cast aluminum alloy
Main box cover : Cast aluminum alloy, Die casting Al
Terminal box : Cast aluminum alloy
Standing Base : Cast aluminium alloy
Pole : Steel pipe
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Ordering Information
E G N A 2 1 5 ① ② ③
EGN Combination Stations Type① Gang number②
EGNA : Standard Type 200 Series : 2 Gang 1000 Series : 10 Gang
EGNF : Factory Sealed Type 300 Series : 3 Gang 1500 Series : 15 Gang
(Without Terminal Box 400 Series : 4 Gang 1800 Series : 18 Gang
in EGNA Type) 500 Series : 5 Gang 2400 Series : 24 Gang
EGNT : Standing Type 600 Series : 6 Gang 3000 Series : 30 Gang
(of EGNA Type) 900 Series : 9 Gang
Combination Type③
No. of Rows & Columns
TYPES ROWS COLUMNSEGN 200 2 1
EGN 300 3 1
EGN 400 4 1
EGN 500 5 1
EGN 600 3 2
EGN 900 3 3
EGN 1000 5 2
EGN 1500 5 3
EGN 1800 6 3
EGN 2400 4 6
EGN 3000 6 5
Control
Copyright by NAMBUK Electric Co., LTD. 2004
2, 3, 4, 5 Gang
TYPESDimensions(mm)
A B C
EGNA 200 130 160 310
EGNA 300 186 216 368
EGNA 400 236 266 420
EGNA 500 286 316 465
6, 10 Gang
TYPESDimensions(mm)
A B C
EGNA 600 210 250 400
EGNA 1000 310 350 500
9, 15 Gang
TYPESDimensions(mm)
A B C
EGNA 900 210 250 400
EGNA 1500 310 350 500
18, 24, 30 Gang
TYPESDimensions(mm)
A B C D E
EGNA 1800 260 450 620 410 296
EGNA 2400 500 320 470 270 540
EGNA 3000 370 500 620 410 406
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Engineering Plastic Combination Stations
EFCS Series
Wet Locations
NEMA 3,3R,4,4X,7,9
Rating : ◎ Max. 250 Volt, Max. 5 Ampere.
Type of Explosion-proof Flameproof-Increase Safety
(Ex de IIC T6 IP66)
Features Application
Enclosure in glass fiber reinforced polyester resin,
provide excellent resistant to corrosion so have a
long life.
Enclosure contains ultraviolet interception ingredient
to resist transformation.
Easy installation and maintenance.
All fixtures are designed to perform from -20 to 4
0 ambient temperature.℃
Any combination of units (1 push button switch, 2
push button switch, pilot lamps, selector switch,
ampere meters, and so on) are available.
EFCS series are used;
in manufacturing plants, refineries, chemical,
petrochemical, and other industrial process facilities,
and other industrial applications.
in areas in which ignitible concentrations of
flammable gases or vapors will be present only due
to abnormal, unusual, accidental conditions.
where combustible dust are present.
in installations where moisture, dirt, dust, vibration,
corrosion, and rough usage are problems.
wherever the damaging effects of water, wind, snow,
sleet, hot sun, or any combination of these elements
are found.Standard Finish
Dark Gray
If you want another color, contact us please.
Standard Materials Options
Main Enclosure : Glass fiber reinforced polyester resin Sunshade cover
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Units Specification Electrical Ratings
Am-meter
Volt-meter
-The Am-meters and Volt-meters are moving iron instruments
with an accuracy class 1.5
-Standard overload scales are max.3 times
-On Am-meters for 1 and 5 Amp C.T connection
500V, n/1 or n/5A
Pilot Lamp-The pilot system based on the use of luminescent diodes as
the lamp source.
LED : AC 110,220V/20mA max.,DC24V
Filament Lamp : AC100,220V/3W
Cam Switch
-Cam Switches max 4 positions are available with conventional
contactors or as a contact-free version.
-The contact arrangements can be selected, spring return or
notched positions can be supplied (refer to contact
arrangement on this page).
Contact Ratings
AC 110V 15Amp.
300V 10Amp.
440V 3Amp.
DC 24V 10Amp.
110V 5Amp.
220V 3Amp.
Selector
Switch
-Selector switches max 4 positions are available.
-The switching arrangements can be selected, spring return or
notched position are available.
AC 250V 6A Contact Rating.
Tumbler
Switch
-Tumbler switches max 4 positions are available.
-The switching arrangements can be selected, spring return or
notched position are available.
AC 250V 6A Contact Rating.
Push Button
Switch
-The standard contact block is double pole, 1 NC (Normally
closed), and 1 NO (Normally Open contact)AC 250V 6A Contact Rating.
Illuminated
Push Button
Switch
-The illuminated push button switch is combination with pilot
lamp and push button switch.LED : AC 110,220V/20mA max., DC24V
Suffix No.
For Operating Magnetic Motor Starter Suffix No.
For ON OFF or Selective Transfer Operation․
Handle Positions Contact Arrangements Handle
Positions Contact Arrangements
1 7
2 8
3 9
4 10
5 11
6 12
Explanation on Operating Diagrams in the TableIn the operating diagrams in the table above, the longitudinal dotted lines show the operating positions of switch, the small circles on the both ends of lateral line show the terminals, and the figures show the terminal numbers.The marks showing the conditions of contacts at each operating position are explained as follows:1. The contact between both terminals is closed at this position.● 2. The contact is closed successively between the two positions.3. The mark of residual contact. The contact is closed when the handle is set to this position and keeps closed ← ◉
after the handle returns. The contact is open at the fine point of the arrow mark when the handle is operated in this direction.
4. A The mark of spring return. The arrow mark shows the direction of automatic spring return form 'A' to the fine point of it.
Control
Copyright by NAMBUK Electric Co., LTD. 2004
1 Gang
Catalog No. Push Button S/W SelectorS/W
Tumbler S/W
Pilot Lamp
illuminatedPush Button
Emergency Push Button
Ampere Meter
Weight (Kg)Single Double
EFCS 101 ○ 0.45
EFCS 102 ○ 0.54
EFCS 103 ○ 0.45
EFCS 104 ○ 0.5
EFCS 105 ○ 0.46
EFCS 106 ○ 0.47
2 Gang
Catalog No.Push Button S/W Selector
S/WTumbler
S/WPilot Lamp
illuminatedPush Button
Emergency Push Button
Ampere Meter
Weight (Kg)Single Double
EFCS 201 ○○ 0.59
EFCS 202 ○ ○ 0.6
EFCS 203 ○○ 0.6
EFCS 204 ○ ○ 0.64
EFCS 205 ○ ○ 0.63
EFCS 206 ○ ○ 0.8
EFCS 207A ○ 0.66
EFCS 208 ○ ○ 0.61
EFCS 209 ○○ 0.58
EFCS 210 ○ ○ 0.7
Control
Copyright by NAMBUK Electric Co., LTD. 2004
3 Gang
Catalog No.Push Button S/W Selector
S/WTumbler
S/WPilot Lamp
illuminatedPush Button
Emergency Push Button
Ampere Meter
Weight (Kg)Single Double
EFCS 301 ○ ○○ 0.83
EFCS 302 ○ ○○ 0.85
EFCS 303 ○ ○○ 0.8
EFCS 304 ○○○ 0.78
EFCS 305 ○○○ 0.75
EFCS 306 ○ ○ ○ 0.84
EFCS 307 ○○ ○ 0.84
EFCS 308 ○ ○ 0.85
EFCS 309 ○ ○ 0.9
EFCS 310 ○ ○ ○ 0.84
EFCS 311 ○○ ○ 0.8
EFCS 312 ○ ○ ○ 0.85
EFCS 313 ○○○ 0.8
12, 28 Gang
Catalog No. Units
EFCS 1200 pilot lamp/ push button S/W(single)/ push button S/W(double)/ emergency push button S/W
ampere meter/ selector S/W(small)/ Tumbler S/W(small)/ illuminated push button S/W and so on.EFCS 2800
Control
Copyright by NAMBUK Electric Co., LTD. 2004
ComponentCat. No. Designation Specification
EFPBPush Button Switch
Component
A Contact (NO : Normally Open)
B Contact (NC : Normally Close)
Max. AC 250V/ 6A
Assembly with PB, DB, IB, EB
EFPLPilot Lamp
Component
AC 110 ~ 250V/ DC 24V/ 20mA
Assembly with PL, IB
EFSSSelector Switch
Component
Max. AC 250V/ 6A
Up to 4 poles
In latching or spring return form
Assembly with SS, SL
EFSCCam Switch
Component
Max. AC 250V/ 6A
Up to 4 poles
In latching or spring return form
Assembly with SS, SL
No.For Operating Magnetic Motor Starter
No.For ON OFF or Selective Transfer Operation․
Handle Positions Contact Arrangements Handle
Positions Contact Arrangements
1 7
2 8
3 9
4 10
5 11
6 12
13
Explanation on Operating Diagrams in the TableIn the operating diagrams in the table above, the longitudinal dotted lines show the operating positions of switch, the small circles on the both ends of lateral line show the terminals, and the figures show the terminal numbers.The marks showing the conditions of contacts at each operating position are explained as follows:1. The contact between both terminals is closed at this position.● 2. The contact is closed successively between the two positions.3. The mark of residual contact. The contact is closed when the handle is set to this position and keeps closed ← ◉
after the handle returns. The contact is open at the fine point of the arrow mark when the handle is operated in this direction.
4. A The mark of spring return. The arrow mark shows the direction of automatic spring return form 'A' to the fine point of it.
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Actuator
Cat. No. Designation Specification
PL Pilot Lamp Color : Yellow/ Red/ Green/ White
PB Push Button SwitchMarking : On/ Off/ Start/ Stop/ Close/ Open/ Auto/
Manual
DB Double Push ButtonMarking : On/ Off/ Start/ Stop/ Close/ Open/ Auto/
Manual
IB Illuminated Push Button Color : Yellow/ Red/ Green/ White
EB Emergency Push Button Color : Red
SS Small Selector Switch Marking : On/ Off/ Start/ Stop/ Close/ Open/ Auto
Manual
SL Large Selector Switch Marking : On/ Off/ Start/ Stop/ Close/ Open/ Auto
Manual
SECTION - 2C
Control Switch
SECTION 2C
Control Switch INDEX
Model Product Description
Certification for
Explosion-proofPAGE
IEC
ETS 5 Circular Tumbler Switch Ex d C T6Ⅱ 2C - 1
ETS 6 Rectangular Tumbler Switch
Ex DP 12Ⅱ
Ex d B T6Ⅱ
Class I Group CD
Class II Group EFG
2C - 2
ELS Limit Switch Ex d IIB T6 2C - 3
EHS Hoist Switch Ex d IIB T6 2C - 3
EPC Photocell Ex d IIB T6 2C - 4
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Type of Explosion-proof Option
Flameproof (Ex d IIC T6) Sunshade Cover
Circular Tumbler Switch
No. of
Gangs
Rated
Current
(A)
Polarity
Catalog Number
Terminal Through Way
1/2" 3/4" 1/2" 3/4"
1
10A
1Pole ETS 51111 ETS 51113 ETSC 51111 ETSC 51113
2Pole ETS 51211 ETS 51213 ETSC 51211 ETSC 51213
3Pole ETS 51311 ETS 51313 ETSC 51311 ETSC 51313
20A
1Pole ETS 51121 ETS 51123 ETSC 51121 ETSC 51123
2Pole ETS 51221 ETS 51223 ETSC 51221 ETSC 51223
3Pole ETS 51321 ETS 51323 ETSC 51321 ETSC 51323
2
10A
1Pole ETS 52111 ETS 52113 ETSC 52111 ETSC 52113
2Pole ETS 52211 ETS 52213 ETSC 52211 ETSC 52213
3Pole ETS 52311 ETS 52313 ETSC 52311 ETSC 52313
20A
1Pole ETS 52121 ETS 52123 ETSC 52121 ETSC 52123
2Pole ETS 52221 ETS 52223 ETSC 52221 ETSC 52223
3Pole ETS 52321 ETS 52323 ETSC 52321 ETSC 52323
3
10A
1Pole ETS 53113 ETSC 53113
2Pole ETS 53213 ETSC 53213
3Pole ETS 53313 ETSC 53313
20A
1Pole ETS 53123 ETSC 53123
2Pole ETS 53223 ETSC 53223
3Pole ETS 53323 ETSC 53323
4
10A
1Pole ETS 54113 ETSC 54113
2Pole ETS 54213 ETSC 54213
3Pole ETS 54313 ETSC 54313
20A
1Pole ETS 54123 ETSC 54123
2Pole ETS 54223 ETSC 54223
3Pole ETS 54323 ETSC 54323
* ETS 4 Gang Type is order made. contact us please.
Tumbler Switches
ETS Series
Wet Locations
NEMA 3,3R,4,4X,7,9
Application FeaturesETS Series are used ;
in locations, made hazardous, due to the presence of
flammable vapors, gases or highly combustible dusts.
to provide manual starting and stopping and in the case of
ETS units with heaters motor running protection.
for installation at petroleum refineries, chemical and
petrochemical plants and in other process industry facilities
where similar hazards exist.
Max. 250 Volt, Max. 20 Ampere.
This tumbler switch is designed to take
larger insulation clearance and durability. The
tumbler switch has metallic lever with roller
to ensure long life under rough operation.
Outside lever shaft is sealed for flameproof,
as well as waterproof, to ensure smooth
operation.
Standard Finish Standard Materials MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Main Box : Cast aluminum alloy
Surface Cover : Die casting aluminium
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Type of Explosion-proof OptionFlameproof (Ex d IIB T6)
Class I Group CD Class II Group EFG
Dust Ignition-proof (Ex DP II 12)
Sunshade Cover
UL File No. E164350
UL Model name is ETS 5.
Rectangular Tumbler Switch
No. of
Gangs
Rated
Current
(A)
Polarity
Catalog Number
Terminal Through Way
1/2" 3/4" 1/2" 3/4"
1
10A
1Pole ETS 61111 ETS 61113 ETSC 61111 ETSC 61113
2Pole ETS 61211 ETS 61213 ETSC 61211 ETSC 61213
3Pole ETS 61311 ETS 61313 ETSC 61311 ETSC 61313
20A
1Pole ETS 61121 ETS 61123 ETSC 61121 ETSC 61123
2Pole ETS 61221 ETS 61223 ETSC 61221 ETSC 61223
3Pole ETS 61321 ETS 61323 ETSC 61321 ETSC 61323
2
10A
1Pole ETS 62111 ETS 62113 ETSC 62111 ETSC 62113
2Pole ETS 62211 ETS 62213 ETSC 62211 ETSC 62213
3Pole ETS 62311 ETS 62313 ETSC 62311 ETSC 62313
20A
1Pole ETS 62121 ETS 62123 ETSC 62121 ETSC 62123
2Pole ETS 62221 ETS 62223 ETSC 62221 ETSC 62223
3Pole ETS 62321 ETS 62323 ETSC 62321 ETSC 62323
3
10A
1Pole ETS 63113 ETSC 63113
2Pole ETS 63213 ETSC 63213
3Pole ETS 63313 ETSC 63313
20A
1Pole ETS 63123 ETSC 63123
2Pole ETS 63223 ETSC 63223
3Pole ETS 63323 ETSC 63323
4
10A
1Pole ETS 64113 ETSC 64113
2Pole ETS 64213 ETSC 64213
3Pole ETS 64313 ETSC 64313
20A
1Pole ETS 64123 ETSC 64123
2Pole ETS 64223 ETSC 64223
3Pole ETS 64323 ETSC 64323
* ETS 4 Gang Type is order made. contact us please.
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Special SwitchesELS, EHS, EPC Series
Wet Locations
NEMA 3,3R,4,4X,7,9
Limit Switches ELS Series
Type of Explosion-proof Flameproof (Ex d IIB T6)
<ELS-L2>
<ELS-L3>
<ELS-L4>
Application
ELS Limit switches are used in areas which are hazardous due
to the presence of flammable vapors or gases and combustible
dusts such as petrochemical plant, thermal power station, oil
refineries, chemical plant and manufacturing paint plant.
Standard Material Body : Cast aluminum alloy
Standard FinishMUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Certification
Certified by KOSHA (Korea Occupational Safety & Health
Agency), KGS (Korea Gas Safety Corporation), and the
others.
Compliance Ordering Number
IEC 60079-0, 1 Catalog No. Actuator Type
ELS-L2 Roller Lever
ELS-L3 Roller Adjust Lever
ELS-L4 Rod Lever
Hoist Switches EHS Series
Type of Explosion-proof Flameproof (Ex d IIB T6)
Standard Materials Terminal Box Cover : Cast
aluminum alloy
Body : Cast aluminum alloy
Cable Connector : Cast
aluminium alloy
Standard FinishMUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Ordering NumberCatalog Number Unit Style
EHS-4 ○○○○
EHS-6 ○○○○○○
+ Other unit style are also available
on request.
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Photocell Switches EPC Series
Type of Explosion-proof Flameproof (Ex d IIB T6)
Application
The EPC 50 remote Photocell is:
Used to provide dusk-to-dawn operation of lighting fixtures.
Used to control lighting circuits in remote locations.
Ideal for walkways, bridges, security lighting, industrial platforms, etc.
Standard Materials Standard Finish
Back Box : Cast aluminum alloy
Cover : Cast aluminum alloy
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Technical DataInput Volt 100~120V, 200~220V
Frequence 60Hz
Contact Rating AC 120V 10AAC 208~277V 5.8A
Operation On: 50 Lux, Off: 150 Lux
Catalog Number EPC 50
Photocell Switches VPC Series
Application
The VPC 50 remote Photocell is:
Used to provide dusk-to-dawn operation of lighting fixtures.
Used to control lighting circuits in remote locations.
Ideal for walkways, bridges, security lighting, industrial platforms, etc.
Standard Materials Standard FinishBack Box : PC/ABS
Cover : PC/ABS
Natural
Technical DataInput Volt 100~120V, 200~220V
Frequence 60Hz
Contact Rating AC 120V 10AAC 208~277V 5.8A
Operation On: 50 Lux, Off: 150 Lux
Catalog Number VPC 50
SECTION - 3C
Circuit Breaker Box &
Motor Starter
SECTION 3C
Circuit Breaker Box & Motor Starter INDEX
Model Product Description
Certification for
Explosion-proofpage
IEC
ECM Circuit Breaker Box & Motor StarterEx d IIB T6
Ex DP II 133C - 1
ECN Circuit Breaker Box & Motor Starter Ex d IIB T6 3C - 3
EPPC Circuit Breaker Box & Motor Starter Ex d IIC T6 3C - 4
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Circuit Breaker Box & Motor Starter
ECM Series
Wet Locations
NEMA 3,3R,4,4X,7,9
Type of Explosion-proof
Flameproof (Ex d IIB T6)
Dust Ignition-proof (Ex DP II 13)
Application
These units contain an effective magnetic motor starter conforming to the
specific standards in the flameproof main enclosures of the rectangular
shape.
The magnetic motor starters interior are manual resetting and are wired
for remote control as standard. The standard units are Through Patterns
having terminal boxes at top and bottom, and a push button for resetting
is mounted on the cover of the main enclosures. Alternatively Terminal
Pattern units having a bus-bar housing at top and a terminal box at
bottom can be supplied on request. Accessories listed in the table can
be furnished to customers' requirements.
Enclosure
Size
Dimensions (mm)Max. Conduit Size
Max. Conduit Size
mm2A B C D E F G H
SS 250 350 200 550 750 270 280 190 42(1-1/2")×2 14
MS 320 540 250 790 1040 330 440 220 42(1-1/2")×2 14
LS 500 510 310 820 1130 550 450 255 54(2")×2 38
EL 500 750 305 1055 1360 550 690 270 70(2-1/2")×2 100
* SS : Small Size, MS : Middle Size, LS : Large Size, EL : Extra Large
Features The bodies of the main enclosure and terminal boxes are
accurately machined to rectangular shape, and each of them and
their covers are closely fitted with plain flanged joints.
The operating mechanisms for the resetting button of magnetic
motor starter interior, push button and selector switch are secure
and smooth. The operating rods are machined to the required
tolerances, and an O-ring and rubber caps are provided for
preventing water and dust coming into the joints. The leading of
conductors through the barrier wall is flame-proof stud type for
main circuit and flameproof sealing type for control circuits.
Standard Materials
Main Enclosure : Cast aluminium alloy
Terminal Box : Cast aluminium alloy
Standard FinishMUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Details of Motor Starters Interior
Rate Catalog No. Size
Electric Motor Terminal
Block
Standard Unit
SequenceRated Capacity
(KW)
Total Load Current (A) Push Button Pilot LampTimer
220V 440V Main On Off Red Green
220V ECM-7.5LS SS 0.05 ~ 7.5 1.2 ~ 22 - 5.5 SQ×6P ○ ○ ○ ○ - A
220V
/440V
ECM-15LS SS 7.5 ~ 15 28 ~ 55 14 ~ 28 22 SQ×6P ○ ○ ○ ○ - A
ECM-15RS MS 7.5 ~ 15 28 ~ 55 14 ~ 28 22 SQ×6P ○ ○ ○ ○ - B
ECM-15SD MS 7.5 ~ 15 28 ~ 55 14 ~ 28 22 SQ×6P ○ ○ ○ ○ ○ C
ECM-37LS MS 19 ~ 37 70 ~ 130 35 ~ 65 100 SQ×6P ○ ○ ○ ○ - A
ECM-37RS MS 19 ~ 37 70 ~ 130 35 ~ 65 100 SQ×6P ○ ○ ○ ○ - B
ECM-37SD MS 19 ~ 37 70 ~ 130 35 ~ 65 100 SQ×6P ○ ○ ○ ○ ○ C
ECM-75LS LS 45 ~ 75 160 ~ 253 80 ~ 126 150 SQ×6P ○ ○ ○ ○ - A
ECM-75RS LS 45 ~ 75 160 ~ 253 80 ~ 126 150 SQ×6P ○ ○ ○ ○ - B
ECM-75SD LS 45 ~ 75 160 ~ 253 80 ~ 126 150 SQ×6P ○ ○ ○ ○ ○ C
440V
ECM-132LS EL 90 ~ 132 305 ~ 440 150 ~ 220 200 SQ×6P ○ ○ ○ ○ - A
ECM-132RS EL 90 ~ 132 305 ~ 440 150 ~ 220 200 SQ×6P ○ ○ ○ ○ - B
ECM-132SD EL 90 ~ 132 305 ~ 440 150 ~ 220 200 SQ×6P ○ ○ ○ ○ ○ C
* LS : Line Starter
RS : Reversible Starter
SD : Star-Delta Starter
* No of terminal block in control line is on request.
* Frequency of magnetic contactor coil is 60Hz. (50Hz is on request)
Optional Accessories a : Illuminator PB
b : Aux Relay
c : Earth Leakage Breaker
d : Potential Transformer & Fuse
e : Emergency Button S/W
f : Over Current Relay
g : Hand Reset Relay
h : Automatic Reset Relay
i : Electromagnetic Contactor
j : Yellow Pilot Lamp
k : Ampere Meter
(A) Line Starting System (B) Reversible Starting System (C) Y- Starting System△
Control
Copyright by NAMBUK Electric Co., LTD. 2003
Circuit Breaker Box & Motor Starter
ECN Series
Wet Locations
NEMA 3,3R,4,4X,7
Type of Explosion-proof Flameproof (Ex d IIB T6)
Enclosure SS MS LS EL
A 250 320 500 500
B 350 540 510 750
C 200 250 310 305
D 550 790 820 1055
E 750 1040 1130 1360
F 270 330 550 550
G 280 440 450 690
H 190 220 255 270
* SS : Small Size, MS : Middle Size,
LS : Large Size, EL : Extra Large
Features
The bodies on the main
enclosure and terminal
boxes are accurately
machined to rectangular
shape, and each of them
and their covers are
closely fitted with plain
flanged joints.
The operating mechanism
for the handle of circuit
breaker interior is secure
and smooth.
The operating rod is
machined to the required
tolerance, and an O-ring
is provided for preventing
water and dust coming
into the joint.
The circuit breakers
interior have automatic
quick break mechanism
for protection of over
current and short-circuit
current. These are the
most suitable for the
switching and protection
of general circuits.
The through pattern units
having terminal boxes an
top and bottom are
supplied as standard.
Alternatively Terminal
Pattern units having a
terminal box at top or
bottom are available for
up to 600A rating in 600A
frame size.
Standard FinishMUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Breaker Frame (AF) 30 50 60 100 225 400 600
Number of poles 2, 3 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4
Rated
Voltage (V)
AC 600 600 600 600 600 600 600
DC 250 250 250 250 250 250 250
Rated Current (A)
at Ambient Temp. 40°C
5
10
15
20
30
5
10
15
20
30
40
50
60 15
20
30
40
50
60
75
100
100
125
150
175
200
225
250
300
350
400
500
600
Rated
Interrupting
capacity (KA)
220VAC 5 10 10 22 30 42 100
460VAC 2.5 5 5 10 22 30 50
600VAC 1.5 2.5 2.5 5 14 25 35
250VDC 2.5 5 5 5 20 40 40
Enclosure Type SS SS SS SS MS LS EL
Catalog No.ECN
8310
ECN
8311
ECN
8312
ECN
8313
ECN
8314
ECN
8315
ECN
8316
Max. Conduit Size1-1/2"
(42C)
1-1/2"
(42C)
1-1/2"
(42C)
2"
(54C)
3"
(82C)
4"
(104C)
4"
(104C)
Max. Conductor Size (mm2) 14 14 14 38 150 250 150 X 2
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Circuit Breaker Box & Motor Starter
EPPC MCCB Box Series
Wet Locations
NEMA 3,3R,4,4X,7
Type of Explosion-proof Flameproof (Ex d IIC T6)
Application
EPPC MCCB Box series are used ;
in heavy process industries having environments where flammable or
explosive vapors or gases, or where combustible dusts are present.
in hazardous areas, both indoors and outdoors where long life and
low maintenance costs are desired.
in petroleum refineries, chemical, petrochemical and other heavy
process industry facilities.
in paint spray booth suitability provides efficient, economical HID
lighting for paint spray areas.
where ignitable concentrations of flammable gases, vapors or liquids
can exist all of the time or some of the time under normal operation
conditions.
in hazardous locations requiring elevated ambient capability.
in installations where moisture, dirt, dust, vibration, corrosion and
rough usage are problems.
Standard Finish DimensionMUNSELL No. 7.5BG 6/1.5
If you want another color, contact us
please.
Frame Size(AF) 100 225
Number of poles 2, 3, 4 2, 3, 4
Rated
Voltage(V)
AC 600 600
DC 250 250
Rated Current(A)
at Ambient Temp. 40°C
15
20
30
40
50
60
75
100
100
125
150
175
200
225
Rated
Interrupting
capacity(KA)
220VAC 22 30
460VAC 10 22
600VAC 5 14
250VDC 5 20
Max. Conduit Size 2"(54C) 3"(82C)
Max. Conductor Size(mm2) 38 150
SECTION - 4C
Circuit Breaker Panel Board
SECTION 4C
Panel Board INDEX
Model Product Description
Certification for
Explosion-proofpage
IEC
EPBC Instrumentation Panel Board Ex de IIB T6 4C - 1
EPDP Appleton Panel Board Ex d IIC T6 4C - 3
EPDS Rectangular Panel Board Ex d IIB T6 4C - 4
EPFS Stainless steel Panel BoardEx de IIC T6
Ex DP II 124C - 6
EFDS Engineering Plastic Panel BoardEx de IIC T6
Ex de IIB T64C - 8
ETR Transformer for Circuit Breaker Panel Board Ex d IIC T6 4C - 10
EDPT Transformer Ex d IIB T4 4C - 11
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Circuit Breaker Panel boards
EPBC Series
Wet Locations
NEMA 3,3R,4,4X,7
Type of Explosion-proof Application
EPBC panel boards are designed specifically for used in ;
Class 1, Division 2, Groups C, D hazardous areas
where flammable vapors or gases may be present
due to accident or abnormal locations.
damp, wet or corrosive locations.
indoors or outdoors in Division 2 areas of
petroleum refineries, chemical and petrochemical
plants, and other process industry facilities.
Flameproof-Increase Safety (Ex de IIB T6)
Features
Enclosures are of external flange
design, which makes the interior
completely accessible when the
cover is removed.
Provided with concealed mounting,
which is made possible by
having our clearance holes for
lag screws or mounting bolts in
the back of the enclosure, one
in each corner.
The interior sub-assembly,
consisting of a mounting plate,
main terminal blocks, branch
circuit terminal blocks and circuit
breakers, is removable as a
complete unit.
Ample gutter space is provided
for ease of field wiring.
Circuit breakers are contained in
compact, individual enclosures
are easily removed and replaced,
therefore changing or adding
individual circuit breakers will not
present a problem.
The main cover, which is
gasketed to exclude dirt and
moisture, is attached to the body
with hex head bolts and is
removed only when installing the
panel-board or making wiring
changes, In the center of the
main cover is a gasketed hinged
door, which provides access
only to the circuit breaker
operating handles, and is held
closed by two quick-release
catches. The door can be locked
by as many as 3 padlocks to
prevent unauthorized operation.
Tapped conduit openings are
provided for main conduit and
branch circuits, as shown in the
dimensional information.
Standard openings can be
reduced or plugged to meet
most installation requirements.
Circuit breakers are arranged in
two vertical rows and have the
circuit numbers marked on the
handles. The left row is
numbered 1, 3, 5, 7, etc. and
the right row 2, 4, 6, 8, etc.
identifying information may be
typed on the circuit directory
card attached to the inside of
the hinged door.
Standard Materials
Body, cover and hinged doors
: Cast aluminium alloy
Interior parts : Sheet steel
Standard FinishMUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Electrical Rating Ranges
Circuit breakers
Single-pole-120/VAC max.
Two-pole-120/24VAC max.
Trip ratings 15, 20 and 30 Amp.
EPBC Explosion-proof Factory Sealed Panel Board
Panel
Size
No. of
Breaker
Catalog Number
Wiring System No.1
1Phase 2Wire
Wiring System No.2
1Phase 3Wire
Wiring System No.4
3Phase 4Wire
1p 2p 1pole 2pole 1pole 2pole 1pole 2pole
#1
6 EPBC1061 EPBC2061 EPBC4061
8 4 EPBC1081 EPBC1042 EPBC2081 EPBC2042 EPBC4081 EPBC4042
10 5 EPBC1101 EPBC1052 EPBC2101 EPBC2052 EPBC4101 EPBC4052
12 6 EPBC1121 EPBC1062 EPBC2121 EPBC2062 EPBC4121 EPBC4062
#2
14 7 EPBC1141 EPBC1072 EPBC2141 EPBC2072 EPBC4141 EPBC4072
16 8 EPBC1161 EPBC1082 EPBC2161 EPBC2082 EPBC4161 EPBC4082
18 9 EPBC1181 EPBC1092 EPBC2181 EPBC2092 EPBC4181 EPBC4092
20 10 EPBC1201 EPBC1102 EPBC2201 EPBC2102 EPBC4201 EPBC4102
22 11 EPBC1221 EPBC1112 EPBC2221 EPBC2112 EPBC4221 EPBC4112
24 12 EPBC1241 EPBC1122 EPBC2241 EPBC2122 EPBC4241 EPBC4122
#3
13 EPBC1132 EPBC2132 EPBC4132
14 EPBC1142 EPBC2142 EPBC4142
15 EPBC1152 EPBC2152 EPBC4152
16 EPBC1162 EPBC2162 EPBC4162
17 EPBC1172 EPBC2172 EPBC4172
18 EPBC1182 EPBC2182 EPBC4182
#419 EPBC1192 EPBC2192 EPBC4192
20 EPBC1202 EPBC2202 EPBC4202
If you need more information, contact us please. ⇨
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Replacement Circuit Breaker Assemblies
Where EPBC panel boards have been ordered with less
than the maximum number of circuit breakers, breakers
can easily be added in the field. Circuit breaker
assemblies for field addition or replacement are listed
below; they consist of the breaker it-self in its factory
sealed Class 1, Division 2, Groups C, D enclosure,
leads for connection to terminal blocks, and necessary
hard-ware.
Ordering Information 1-Pole Circuit Breaker Assemblies Ampere
Panel boards are available with 15, 20 or 30
ampere circuit breakers. To order a panel board
with all breakers of the same ration add the
desired rating as a suffix to the Cat. No. For
example, the 12 circuit EPBC 2512 panel board
with all the circuit breakers rated 20 amperes
would be ordered as EPBC 2512-20.
Panel boards can be furnished with an
assortment of breaker rations. To order, the
quantities and ampere ratings are added as
suffixes to the Cat. No. For example, the 12
circuit EPBC 2512 with six 15 ampere, four 20
ampere and two 30 ampere circuit breakers
would be ordered as EPBC 2512-615-420-230.
The EPBC with a main breaker is available up to
100 amps. To order EPBC with main breaker,
add the appropriate suffix. Example. EPBC
2512-15 with 3 pole, 100 amp main circuit
breaker would be ordered as EPBC 2512-15-3M
100. If 2 pole main is required, change the
number 3 to 2 if a lower trip rating than 100 is
required, the suffix will change accordingly.
Rating
15 EPC11-15
20 EPC11-20
30 EPC11-30
2-Pole Circuit Breaker Assemblies Ampere
Rating
15 EPC11-15
20 EPC11-20
30 EPC11-30
Dimensions (mm)
TYPE A B C D E
#1 572 526 406 582 210
#2 572 718 406 776 210
#3 572 945 406 1003 270
#4 572 1085 406 1143 270
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Circuit Breaker Panelboards
EPDP Series
Outdoor use
IEC Code: Ex d IIC
ZONE1 & ZONE2
Type of Explosion-proof Flameproof (Ex d IIC T6)
Application Features
Protection and control of lighting
and power distribution in
classified locations or in damp,
wet, or corrosive conditions.
Designed for use in
manufacturing and processing
areas where ignitable vapors,
gases or highly combustible
dusts are present.
Panel size-accommodate from 6
thru 24 two-pole circuit breaker
spaces as standard. It could be
extended & provided more 24ckts
breakers as selection.
Housing pivots 180° for removal of
breaker cover.
Both junction and breaker compartments
fully gasketed for raintight fit.
No external branch seal fittings
need-ed-factory sealed enclosures.
Each branch circuit breaker is lockable
in ON or OFF position.
Circuit directory card-Clear plastic
cover.
Main feed conduit openings at both top
and bottom of enclosure allow main
feed entry at either center of enclosure.
Canopy(sun shade) is provided as
option.Standard FinishBS4800 Shade 10-A-3
If you want another color,
contact us please.
Breaker Amperage
16 32,63,....max225
Dimensions
<Size 1> <Size 3> <Size 2> <Size 4>
<Size 5>
EPDP Explosion-proof Factory Sealed Panel Board
Panel
Size
No. of
Breaker
Catalog Number
Wiring System No.1
1Phase 2Wire
Wiring System No.2
1Phase 3Wire
Wiring System No.3
3Phase 3Wire
Wiring System No.4
3Phase 4Wire
1p 2p 3p 1pole 2pole 1pole 2pole 2pole 3pole 2pole 3pole
16 EPDP1061 EPDP2061
8 4 2 EPDP1081 EPDP1042 EPDP2081 EPDP2042 EPDP3042 EPDP3023 EPDP4042 EPDP4023
210 5 EPDP1101 EPDP1052 EPDP2101 EPDP2052 EPDP3052 EPDP4052
12 6 3 EPDP1121 EPDP1062 EPDP2121 EPDP2062 EPDP3062 EPDP3033 EPDP4062 EPDP4033
314 7 EPDP1141 EPDP1072 EPDP2141 EPDP2072 EPDP3072 EPDP4072
16 8 4 EPDP1161 EPDP1082 EPDP2161 EPDP2082 EPDP3082 EPDP3043 EPDP4082 EPDP4043
418 9 EPDP1181 EPDP1092 EPDP2181 EPDP2092 EPDP3092 EPDP4092
20 10 6 EPDP1201 EPDP1102 EPDP2201 EPDP2102 EPDP3102 EPDP3063 EPDP4102 EPDP4063
522 11 EPDP1221 EPDP1112 EPDP2221 EPDP2112 EPDP3112 EPDP4112
24 12 8 EPDP1241 EPDP1122 EPDP2241 EPDP2122 EPDP3122 EPDP3083 EPDP4122 EPDP4083
614 EPDP1142 EPDP2142 EPDP3142 EPDP4142
16 10 EPDP1162 EPDP2162 EPDP3162 EPDP3103 EPDP4162 EPDP4103
718 EPDP1182 EPDP2182 EPDP3182 EPDP4182
20 12 EPDP1202 EPDP2202 EPDP3202 EPDP3123 EPDP4202 EPDP4123
822 14 EPDP1222 EPDP2222 EPDP3222 EPDP3143 EPDP4222 EPDP4143
24 16 EPDP1242 EPDP2242 EPDP3242 EPDP3163 EPDP4242 EPDP4163
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Circuit Breaker Panel Board
EPDS Series
Wet Locations
NEMA 3,3R,4,4X,7
Type of Explosion-proof Flameproof (Ex d IIB T6)
Features
In each housing the cover is fitted the body
with cylindrical joint for highly reliable
flameproof and weatherproof properly. The
breaker housings and separable from busbar
housing by the flameproof packing type seal.
Both built-in breaker and the operating handle
are installed on the cover. They can be pulled
out together with the cover by releasing four
fixing bolts for maintenance.
Busbar housing contains the bus bars and
leads, and provides terminal at the lower end.
Application Standard Materials Standard Finish
This range of EPDS panel
boards is designed for high
degree of flameproof protection,
good weatherproofness, and
easy installation and
maintenance.
These are constructed and
assembled with breaker
housings, busbar housing and a
branch terminal housing in
accordance with the number of
branch circuits.
Breaker Housing :
Cast aluminium alloy
Main & Branch Bus Bar Housing
: Cast aluminium alloy
Terminal Box :
Cast aluminium alloy
Mounting Frame : Steel
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Details of Breakers
Description Circuit Breaker Motor Breaker
Frame Size 50A 50A
No.of Poles 2 | 3 3
Rated Voltage 400/440V AC 400/440V AC
Rated Current 5, 10, 15, 20 or 30A 15KW Max.
Rated Interrupting 5KA at 460V AC 5KA at 460V AC
The EPDS with a main breaker is available up to 225 amps. To order EPDS with main breaker, add the appropriate
suffix. Example: EPDS 2122-20 with 3pole, 100Amp main circuit breaker would be ordered as EPDS
2122-20-3M100. If 2pole main is required change the number 3 to 2. If a other trip rating then 100 is required, the
suffix will change accordingly.
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Flameproof EPDS Panel Boards
Panel
Size
No. of
Breaker
Catalog Number
Wiring System No.1
1Phase 2Wire
Wiring System No.2
1Phase 3Wire
Wiring System No.3
3Phase 3Wire
Wiring System No.4
3Phase 4Wire
1pole 2pole 1pole 2pole 2pole 3pole 2pole 3pole
1 4 EPDS 1041 EPDS 1042 EPDP 2041 EPDP 2042 EPDP 3042 EPDP 3043 EPDP 4042 EPDP 4043
2 6 EPDS 1061 EPDS 1062 EPDP 2061 EPDP 2062 EPDP 3062 EPDP 3063 EPDP 4062 EPDP 4063
3 8 EPDS 1081 EPDS 1082 EPDP 2081 EPDP 2082 EPDP 3082 EPDP 3083 EPDP 4082 EPDP 4083
4 10 EPDS 1101 EPDS 1102 EPDP 2101 EPDP 2102 EPDP 3102 EPDP 3103 EPDP 4102 EPDP 4103
5,2 12 EPDS 1121 EPDS 1122 EPDP 2121 EPDP 2122 EPDP 3122 EPDP 3123 EPDP 4122 EPDP 4123
2 14 EPDS 1141 EPDS 1142 EPDP 2141 EPDP 2142 EPDP 3142 EPDP 3143 EPDP 4142 EPDP 4143
3 16 EPDS 1161 EPDS 1162 EPDP 2161 EPDP 2162 EPDP 3162 EPDP 3163 EPDP 4162 EPDP 4163
3 18 EPDS 1181 EPDS 1182 EPDP 2181 EPDP 2182 EPDP 3182 EPDP 3183 EPDP 4182 EPDP 4183
4 20 EPDS 1201 EPDS 1202 EPDP 2201 EPDP 2202 EPDP 3202 EPDP 3203 EPDP 4202 EPDP 4203
4 22 EPDS 1221 EPDS 1222 EPDP 2221 EPDP 2222 EPDP 3222 EPDP 3223 EPDP 4222 EPDP 4223
5 24 EPDS 1241 EPDS 1242 EPDP 2241 EPDP 2242 EPDP 3242 EPDP 3243 EPDP 4242 EPDP 4243
PANEL SIZEA TYPE (2P MCCB) B TYPE (3P MCCB)
H1 H2 H3 H4 H1 H2 H3 H4
1 705 755 145 280 860 910 194 378
2 840 890 145 280 1040 1090 194 378
3 985 1035 145 280 1240 1290 194 378
4 1120 1170 145 280 1420 1470 194 378
5 1265 1315 145 280 1620 1670 194 378
APPLICATION Branch 1-POLE, MCCB
Branch 3-POLE, MCCB
2-POLE, MCCB ELCB
Dimensions
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Circuit Breaker Panel Board
EPFS Series
Wet Locations
Factory Sealed
NEMA 3,4,4X,7,9
<EPFS W 3063 - DBSC>
Breaker
Enclosure
Type of Explosion-proof Flameproof-Increase Safety (Ex de IIC T6)
Dust Ignition-proof (Ex DP II 12)
Application
EPFS Series panel boards are used ;
in locations which are hazardous due to the
presence of flammable vapors or gases and where
dampness or corrosion are present.
for indoor and outdoor applications in petroleum
refineries, chemical and petrochemical plants, and
other process industry facilities where similar hazards
exist.
Features
Factory sealed - no external seal required.
Fully wired from circuit breaker housing to
pre-numbered terminals in wiring compartment.
Stainless steel construction provides excellent
resistance to corrosion.
Circuit breakers are contained in compact, individual
factory sealed enclosured suitable for flameproof
hazardous location.
Two inner wiring type - Bus Bar type, Wire type.
Silicone cover gasket provides a watertight seal to
meet IP65.
Standard is IP65, but IP66 can order made.
Standard Materials Compliance Standard Finish
Enclosure : Stainless steel
Interior parts : Aluminum alloy
IEC 60079-0, 1, 7
NEMA 3, 4, 4X, 7, 9
Natural
If you want another color,
contact us please.
Options Certification
Drain and breather
Grounded neutral lug
Sunshade cover
Can use cable gland instead of
coupling
Test button with ELB
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Technical DataElectrical Rating
Main Breaker Max. 600V / 225AF / 225AT / 4P
Branch Breaker Max. 600V / 100AF / 100AT / 3P
Entry Size Max. 2-1/2" - 6EA
If you need more information, contact us please. ⇨
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Panel
Size
Wire Type Bus Bar Type Dimension
Max. No
of Breaker
3 phase 3 wire Max. No
of Breaker
3 phase 3 wire (mm)
2 pole 3 pole 2 pole 3 pole A B C
A 18 EPFS W 3182 EPFS W 3183 14 EPFS B 3142 EPFS B 3143 1500 950 230
B 12 EPFS W 3122 EPFS W 3123 10 EPFS B 3102 EPFS B 3103 1200 950 230
C 8 EPFS W 3082 EPFS W 3083 - - - 1200 700 230
D 6 EPFS W 3062 EPFS W 3063 - - - 1200 550 230
Ordering Information
When ordering refer to below and contact us
please
Quantity of breakers in wire type panel board is
with terminal block and in bus-bar type panel
board is without terminal block.
Panel board size are only use NAMBUK
standard breakers. If you want use other size
breaker, contact us please.
Standard Breaker is Main Breaker : MCCB
50AF/100AF/225AF Branch Breaker : ELCB
50AF/100AF
EPFS Series can install Max. two main breaker
(Standard is one main breaker)
Ordering with specify position and size of
conduit entries (Max. 2-1/2" 6EA)
Ordering with quantity and amperes of branch
breakers
E P F S B 3 0 4 2 - 5 0 - S N DB ① ② ③ ④ ⑤ ⑥ ⑦
EPFS Panel Board① Quantity of Breakers④
04 - 4 Circuit
18 - 18 Circuit
Inner Wiring Type②
B - Bus Bar No. of Breaker Poles⑤
W - Wire 2 -2 Pole / 3 -3 Pole
Amp. of Main Breaker⑥
Wiring System No.③ 50 - 50A / 225 - 225A
2 - 1 phase 3 wire
3 - 3 phase 3 wire Option⑦
4 - 3 phase 4 wire SN - Solid Neutral Lug
DB - Drain & Breather
SC - Sunshade cover
Dimension Inner Wire Type
<Wire Type>
<Bus Bar Type>
Control
Copyright by NAMBUK Electric Co., LTD. 2005
Circuit Breaker Panel Board
EFDS Series
Wet Locations
Factory Sealed
NEMA 3,4,4X,7,9
<Factory Sealed Breaker>
Type of Explosion-proof Flameproof-Increase safety (Ex de IIC T6)
Application
EFDS Series panel boards are used ;
in locations which are hazardous due to the
presence of flammable vapors or gases and where
dampness or corrosion are present.
for indoor and outdoor applications in petroleum
refineries, chemical and petrochemical plants, and
other process industry facilities where similar hazards
exist.
Features
Factory sealed - no external seal required.
Fully wired from circuit breaker housing to
pre-numbered terminals in wiring compartment.
Eng. plastic construction provides excellent
resistance to corrosion.
Circuit breakers are contained in compact, individual
factory sealed enclosured suitable for flameproof
hazardous location.
Standard circuit breaker housing material is glass
fiber reinforced polyester. (Cast Al circuit breaker is
order made)
Silicone cover gasket provides a watertight seal to
meet IP66.
Standard Materials Compliance Standard Finish
Main Enclosure : Glass fiber
reinforced polyester
Circuit Breaker : Glass fiber
reinforced polyester
IEC 60079-0, 1, 7
NEMA 3, 4, 4X, 7, 9Enclosure - Dark Gray
Breaker - Black
Certification
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.Technical Data
Electrical Rating
Main Breaker Max. 600V / 225AF / 225AT / 4P
Branch Breaker
Max. 600V / 100AF / 100AT / 3PStandard circuit is Max. 24 Circuit.
Left breakers are standard.
If you want more circuit or another type
breaker, contact us please.
Max. 600V / 50AF / 50AT / 3P
Max. 600V / 63AT / 4P
Max. 600V / FR 50AF / 50AT / 2P
Max. 600V / 63AF / 63AT / 2P
Entry Size Max. 3" - 2EA / Box
If you need more information, contact us please. ⇨
Control
Copyright by NAMBUK Electric Co., LTD. 2005
Ordering Information
When ordering refer to below and contact us
please
Quantity of breakers are Max. 24 circuit. If you
want more circuit, contact us.
Standard breaker is
Main Breaker : MCCB 50AF/100AF/225AF
Branch Breaker : ELCB 50AF/100AF/63AF
EFDS Series can install multi main breaker
(Standard is one main breaker)
Ordering with specify position and size of
conduit entries (Max. 3" - 2EA)
Ordering with quantity and amperes of branch
breakers
E F D S 3 2 4 3 - 5 0 ① ② ③ ④ ⑤
EFDS Panel Board① No. of Breaker Poles④
1 - 1 Pole
Wiring System No.② 2 - 2 Pole
1 - 1 phase 2 wire 3 - 3 Pole
2 - 1 phase 3 wire 4 - 4 Pole
3 - 3 phase 3 wire
4 - 3 phase 4 wire Amp. of Main Breaker ⑤
50 - 50A
Quantity of Breakers③ 100 - 100A
04 - 4 Circuit 225 - 225A
24 - 24 Circuit
Inner of EFDS
< Inner of EFDS Panel > <Breaker Part> <Busbar Part>
Reference Dimension
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Transformer for Circuit Breaker Panelboards
ETR Series
Wet Locations
NEMA 3,3R,4,4X,7
Type of Explosion-proof Flameproof (Ex d IIC T6(H2) IP55)
Application Features
EPDS Circuit Breaker Panelboard
assemblies with ETR Transformers
are for use;
indoors or outdoors in Zone 1
areas such as petroleum
refineries, chemical and
petrochemical plants, and other
process industry facilities
where high voltage supply must
be stepped down to the lower
voltage necessary to serve
lighting, heating, appliance, heat
tracing, motor and similar circuit
For general information on
panelboard applications, circuit
breakers and wiring systems, refer
to catalog section 4C.
The factory assembled panelboard and
transformer are on one compact frame,
suitable for either wall or pole mounting.
Wiring between the transformer
secondary and main lugs of the
panelboard id accomplished at the
factory.
Easy to install and wire. The main feed
is connected to the transformer primary
and the branch circuits are wired to the
panelboard terminal blocks.
Transformers are compound filled or
epoxy filled to completely seal out
moisture and dirt.
The assembly can be installed in the
load area to reduce the length of runs
of low voltage branch circuits.
Standard Materials Ordering Check ListEnclosure : Sheet Steel 1. Select the EPDS Circuit breaker panelboard required, together with any
applicable options or special features.
2. Provide the following information, necessary for selection of the correct
transformer.
- Primary voltage
- Secondary voltage
- KVA rating
- Taps - number and percent
- Frequency (Standard is 60Hz)
- Single or three-phase
- Other requirement
Size RangeTransformer
Single or three phase
5KVA to 30KVAPanelboard
Standard is 12 circuit (3p)
If you want more circuit, contact
us.
Electrical RatingPrimary - 480V
Secondary - 120/ 240V
Dimensions
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Step-down Transformers
EDPT Series
Wet Locations
NEMA 3, 3R, 4, 4X, 7
Type of Explosion-proof
Flameproof (Ex d IIB T4)
<Single Type>
<Twin Type>
Standard Materials Selection Table of Rubber Packings for Cable Enteries
Main Body : Cast Aluminum alloy
Switched Socket Housing :
Die-casting aluminum
Plug Casing : Die-casting aluminium
Base : Steel
Packing No.
Nominal Diameter of Cable
Suitable Chloroprene Sheathed Portable Power Cable, Class 3
Incoming
Cable
Gland
28-18 16 to 18 mm 3 core 2.0 mm2
28-20 16 to 20 mm 3 core 3.5 mm2
28-21 20 to 21 mm 3 core 5.5 mm2
28-22 21 to 22 mm 3 core 8 mm2
Standard Finish
Output
Plugs
15S 13 to 15 mmMUNSELL No. 7.5BG 6/1.5
If you want another color, contact us
please.
16S 15 to 16 mm 3 core 0.75 mm2
17S 16.5 to 17 mm 3 core 2.0 mm2
Unless otherwise stated the transformers are supplied with No. 28-20 packing for incoming cable gland and with No 17S packing for output plugs.3 core 0.75mm2 Chloroprene Sheathed Portable Power Cable can be supplied in cut lengths to suit customers' requirement.
Rating / Catalog No.
No. of Sockets
Capacity(VA)
Socket
Rating
Secondary
Current(A)Primary
Voltage(V)Secondary Voltage(V)
Catalog No.Weight
(kg)
Conduit Entry
(Single Socket)
- Terminal
28 (1") max.
Specify the
size ordering.
Single 200 15A
250V
2P+E
5100
200
24 EDPT 5119
24 EDPT 521
Twin 250 5 X 2100
200
24 EDPT 51220
24 EDPT 522
Application Features EDPT transformer units are primarily designed for supplying safety low voltages to small appliances such as handlamp. These units are provided with switched socket outlets and plugs to which the appliances are to be connected.
The body, both single socket and twin socket types, is cast in one piece, comprising the main enclosure and a terminal chamber with barrier wall between. The socket outlets are provided on the cover of the enclosure. The cover mountings of the single socket unit are spigot joint with O-ring for main enclosure and threaded joint with O-ring for terminal chamber. Those of the twin socket unit are flanged joint for main enclosure and spigot joint with O-ring for terminal chamber.Replacement of fuse link can be made by removal of the cover of main enclosure for the single socket unit, and by removal of the exclusive screw-on cover for the twin socket unit
Control
Copyright by NAMBUK Electric Co., LTD. 2005
Circuit Breaker Panel Board
EFDS Series
Wet Locations
Factory Sealed
NEMA 3,4,4X,7,9
<Factory Sealed Breaker>
Type of Explosion-proof Flameproof-Increase safety (Ex de IIC T6)
Application
EFDS Series panel boards are used ;
in locations which are hazardous due to the
presence of flammable vapors or gases and where
dampness or corrosion are present.
for indoor and outdoor applications in petroleum
refineries, chemical and petrochemical plants, and
other process industry facilities where similar hazards
exist.
Features
Factory sealed - no external seal required.
Fully wired from circuit breaker housing to
pre-numbered terminals in wiring compartment.
Eng. plastic construction provides excellent
resistance to corrosion.
Circuit breakers are contained in compact, individual
factory sealed enclosured suitable for flameproof
hazardous location.
Standard circuit breaker housing material is glass
fiber reinforced polyester. (Cast Al circuit breaker is
order made)
Silicone cover gasket provides a watertight seal to
meet IP66.
Standard Materials Compliance Standard Finish
Main Enclosure : Glass fiber
reinforced polyester
Circuit Breaker : Glass fiber
reinforced polyester
IEC 60079-0, 1, 7
NEMA 3, 4, 4X, 7, 9Enclosure - Dark Gray
Breaker - Black
Certification
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.Technical Data
Electrical Rating
Main Breaker Max. 600V / 225AF / 225AT / 4P
Branch Breaker
Max. 600V / 100AF / 100AT / 3PStandard circuit is Max. 24 Circuit.
Left breakers are standard.
If you want more circuit or another type
breaker, contact us please.
Max. 600V / 50AF / 50AT / 3P
Max. 600V / 63AT / 4P
Max. 600V / FR 50AF / 50AT / 2P
Max. 600V / 63AF / 63AT / 2P
Entry Size Max. 3" - 2EA / Box
If you need more information, contact us please. ⇨
Control
Copyright by NAMBUK Electric Co., LTD. 2005
Ordering Information
When ordering refer to below and contact us
please
Quantity of breakers are Max. 24 circuit. If you
want more circuit, contact us.
Standard breaker is
Main Breaker : MCCB 50AF/100AF/225AF
Branch Breaker : ELCB 50AF/100AF/63AF
EFDS Series can install multi main breaker
(Standard is one main breaker)
Ordering with specify position and size of
conduit entries (Max. 3" - 2EA)
Ordering with quantity and amperes of branch
breakers
E F D S 3 2 4 3 - 5 0 ① ② ③ ④ ⑤
EFDS Panel Board① No. of Breaker Poles④
1 - 1 Pole
Wiring System No.② 2 - 2 Pole
1 - 1 phase 2 wire 3 - 3 Pole
2 - 1 phase 3 wire 4 - 4 Pole
3 - 3 phase 3 wire
4 - 3 phase 4 wire Amp. of Main Breaker ⑤
50 - 50A
Quantity of Breakers③ 100 - 100A
04 - 4 Circuit 225 - 225A
24 - 24 Circuit
Inner of EFDS
< Inner of EFDS Panel > <Breaker Part> <Busbar Part>
Reference Dimension
SECTION - 5C
Grounding Indicator &
Cable Reel
SECTION 5C
Ground Indicator & Cable Reel INDEXModel Product Description
Certification for
Explosion-proofpage
EGI Grounding Indicator Ex ibd IIB T6 5C - 1
CRA Cable Reel Ex d IIB T6 5C - 2
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Ground Indicator
EGI SeriesNEMA 3, 3R, 4, 4X, 7
Type of Explosion-proof Flameproof (Ex ibd IIB T6)
< EGI 102 >
Application EGI Series are connected to tank vehicles, drums or other portable containers before beginning transfer of combustible materials to :
safely ground static electricity preventing build up of a static charge during pumpingindicate the presence of safe static grounding before and during loading or unloading operationsactuate remote devices (lights, buzzer) to verify completion or interruption of the static groundshut down pumps automatically if the EGI grounding circuit is broken
CautionsPlease this product installs and uses only dangerous location by explosion-proof rule because of Flameproof Enclosure construction.Necessary check whether it was completely joined screw combine part of apparatus.Necessary cut off source when apparatus opens for install, maintain and don't supply the source when apparatus is open.Remove dust or other matter for not happened gap at joint part when opens or closes apparatus and completely screw with tools without hole when screws bolt. Features
1/2" conduit hub for clampTwo pilot lights by LEDColor of Pilot lights makes up red and greenFlameproof Enclosure constructionHeavy duty clamp for static ground connectionStandard Cable length : 10m(If you need another length, contact us please.)
Catalog NumberUnit Catalog No.
Two pilot light EGI 101
Two pilot light/ Buzzer/ Switch EGI 102
Dimension
< EGI 102 > < EGI 101 >
OperationsWhen connected to a truck prior to loading or unloading, the presence of a safe ground is indicated by a green light and the absence of ground is indicated by a red light and a buzzer.Interlocking circuitry will prevent pumps from starting until a ground is established or shut pumps down if a ground is lost at any time during loading or unloading.
Electrical Rating Ranges Source -220V AC, 60Hz Control Relay - DC 12V, DC 6V, 3A Cable - CTF 2C×3.5SQ
Standard Materials Housing Cast Aluminium Alloy Clamp - Engineering Plastic or Cast
Aluminium
Standard FinishMUNSELL No. 7.5BG 6/1.5If you want another color, contact us please.
Control
Copyright by NAMBUK Electric Co., LTD. 2004
Auto Cable Reel
CRA Series NEMA 3, 3R, 4, 4X, 7
Type of Explosion-proof
Flameproof (Ex d IIB T6)
Application
CRA Series Cable Reels are used ;
in be available to use Grounding Indicator
and Hand Lamp in NAMBUK.
in designed for lift, pick-up and suspension
applications in hazardous location containing
flammable vapors, gases or combustible
dust.
in transfers safe, uninterrupted power or
control signals for equipment requiring 3.5㎟
to 5.5 Type SO oil-resistant cable with 2 ㎟
to 3 conductors.
< CRA >
Standard Materials Features
Steel frame and reel sides
Brushes are high-density copper-graphite
Collector rings are copper
Compact size, light weight and rugged
construction for long service with minimum
maintenance.
Fast and easy installation.
Safety ground through separate collector ring
and frame provides positive grounding path.
Lifetime-lubricated bearings reduce
maintenance.
Easy-to-remove cover provides quick access
to springs.
Built-in cable locking ratchet is provided with
reel and can be easily activated when
required.
For longer cable length applications.
Compliance & Certification
IEC 60079-0, 1
Certified by KOSHA (Korea Occupational Safety & Health
Agency), KGS (Korea Gas Safety Corporation), and the
others.
Standard Finish
Baked on Epoxy Powder - 7.5BG 6/1.5 8N-7
If you want another color, contact us please.
Technical Data
Cat. No. CRA 1 CRA 2 CRA 3
Outlet Available
TypeFour Roller Swivel Type Two Roller
Max Bending
Degree60° 225° 180° Dimension
Ca
ble
Conductors SO Type 2 to 3 conductors
Size 3.5 to 5.5 ㎟
Length 10 m (standard)
Suffix GR for grounding indicator.※
Cable Length is available to be adjusted in accordance ※
with your order.
Ordering Information
These Reels are shipped with ratchets which are "locked
out" for constant cable tension. These ratchets can be
easily field-activated where cable locking is desired.
If you need more information, contact us please. ⇨
SECTION - 1P
Plug & Receptacle
SECTION 1P
Plug & Receptacle INDEXModel Product Description
Certification for
Explosion-proofPage
VWPR VWPR 15A, 20A Weatherproof Type 1P - 1
VPR VPR 30A, 60A, 100A Weatherproof Type 1P - 2
EUPR EUPR 20A Ex d IIB T6 1P - 3
EDPR EDPR 60A Weather proof Type 1P - 4
EPR EPR 20A, 30A, 100A Ex de IIB T6 1P - 5
EPRH EPRH 20A, 100AEx de IIC T6 IP55
Ex de IIC T61P - 9
Plug & Receptacle
Copyright by NAMBUK Electric Co., LTD. 2004
Plugs And Receptacles
VWPR SeriesWeatherproof Type
<VWP> <VWR>
Dimension
Application Standard Materials
VWP Plugs and VWR Receptacles are used ;
wherever dust, dirt, moisture and corrosion are a
problem.
outdoor or in locations where frequent
washdowns occur, as in dairies and food
processing plant.
Receptacle : Cast aluminium alloy
Cap : Cast aluminium alloy
Device Box : Cast aluminium alloy
Electrical Rating Ranges
15 Amperes
20 AmperesFeatures
VWR receptacle housing are used :
with cast device boxes, either surface mounted or
installed flush in a wall.
with single gang, two gang tandem and multiple
gang boxes having individual cover openings.
A threaded cap which effectively seal housing
when not use.
VWP Plugs included :
A molded Neoprene hood with integral sleeve to
seal the cord entrance
A aluminum ring which clamps the hood to
receptacle housing face, to complete watertight
seal when plug is in use.
VWR Receptacles and VWP Plugs
RatingCover with
Recept. Cat #Style Plug Cat # Cord Dia.
15 Amp.
125 VoltsVWR-1512
2 Wire
3 PoleVWP-1512 1.27~15.8
15 Amp.
250 VoltsVWR-1525
2 Wire
3 PoleVWP-1525 1.27~15.8
20 Amp.
125 VoltsVWR-2012
2 Wire
3 PoleVWP-2012 1.27~15.8
20 Amp.
250 VoltsVWR-2025
2 Wire
3 PoleVWP-2025 1.27~15.8
Standard FinishMUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Plug & Receptacle
Copyright by NAMBUK Electric Co., LTD. 2004
Plugs And Receptacles
VPR SeriesWeatherproof Type
< VPR > < VPP >
Dimension
<VPR 30A>
<VPR 60A>
Application Heavy Duty & Weatherproof VPR Receptacles & VPJ Plugs
Circuit breaking plugs and receptacles are used :
to supply power to portable electrically
operated devices such as motor-generator
sets, compressors, heating and cooling units,
weldes, conveyors, lighting systems and
similar equipment
where temporary power is needed, such as at
trailers, building units, heavy machinery and
similar equipment
wherever electrical loads must be quickly
disconnected from power source
in Indoors and outdoors in non-hazardous
areas of chemical plants, process industry
facilities, meat packing plants, manufacturing
plants and similar industrial locations
Receptacle Plug
Hub Size Cat No. Cable Dia Cat No.
30A
~
480VAC
3 Wire
3Pole
3/4"(22C) VPR-3133 13.0 to 17.8 VPP-3133
1"(28C) VPR-3233 17.8 to 21.6 VPP-3233
3 Wire
4 Pole
3/4"(22C) VPR-3134 13.0 to 17.8 VPP-3134
1"(28C) VPR-3234 17.8 to 21.6 VPP-3234
60A
~
480VAC
3 Wire
3Pole
1"(28C) VPR-6133 19.1 to 27.2 VPP-6133
1-1/4"(36C) VPR-6233 27.2 to 34.3 VPP-6233
3 Wire
4 Pole
1"(28C) VPR-6134 19.1 to 27.2 VPP-6134
1-1/4"(36C) VPR-6234 27.2 to 34.3 VPP-6234
100A
~
480VAC
3 Wire
3Pole
1-1/2"(42C) VPR-10133 24.1 to 34.8 VPP-10133
2"(54C) VPR-10233 34.7 to 38.1 VPP-10233
3 Wire
4 Pole
1-1/2"(42C) VPR-10134 24.1 to 34.8 VPP-10134
2"(54C) VPR-10234 34.7 to 38.1 VPP-10234
Standard Materials
Switch receptacle Housing :
Cast aluminium alloy
Plug and Receptacle's Back Box :
Cast aluminium alloy
Dimension
<VPR 3020>
Standard FinishMUNSELL No. 7.5BG 6/1.5
If you want another color, contact us
please.
Plug & Receptacle
Copyright by NAMBUK Electric Co., LTD. 2004
Plugs And Receptacles
EUPR SeriesNEMA 3, 3R
Type of Explosion-proof Flameproof (Ex d IIB T6)
< EUPR >
Application
EUR receptacles and EUP plugs are used :
with portable electrically operated devices such as
motor-generator sets, compressors, conveyors, portable tools,
lighting systems and similar equipment.
in locations which are hazardous due to the presence of
flammable vapors or gases.
in damp or corrosive locations
in petroleum refineries, chemical and petrochemical plants, and
other process industry facilities where similar hazards exist.
Dimension(mm) Features
The delayed action feature permits the plug to be
used as an emergency pushpull switch.
EUR receptacles are equipped with a rotating
mechanism which prevents complete withdrawal of
the EUP plug in one continuous movement.
The receptacles are factory sealed to simplify
installation and wiring-external seals are not
required.
The receptacles have top hinged cover design, with
45° downward angled receptacle housing, to provide
superior environmental protection from
accumulations of dust, show , ice and water.
The plug withdrawn until it is stopped by the
delayed action mechanism. In this position the
circuit has been broken and the arc has been
snuffed in the contact chambers.
To completely withdraw the plug, the delayed action
release lever must be rotated counterclockwise.
When inserting the plug, the reverse procedure is
followed.
Standard Materials
Receptacle housings : Die casting aluminium
Plug housings : Die casting aluminium
Back boxes : Cast aluminium alloy
Insulation : Fiberglass reinforced polyester
EUP Explosion proof Plugs Standard Finish Rating Poles Cable Diameter Cat NO.
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.20 Amp.2 Wire
3 Pole
8 to 11 EUP 2011
9.5 to 12.7 EUP 2013
12.7 to 16 EUP 2016
Grounding EUR Explosion proof Factory sealed Circuit Breaking Receptacles
Receptacles and plugs
are provided with an
extra grounding pole.
In plugs, provision is
made for attachment
of the grounding wire
to the plug housing.
Rating Style Description Thread SizeCatalog Number
Single Gang Two Gang Three Gang
20Amp.
125-240VAC
18VDC
2 Wire
3 Pole
Dead
End
1/2"(16C) EUR 2011 EUR 2021 EUR 2031
3/4"(22C) EUR 2012 EUR 2022 EUR 2032
1"(28C) EUR 2013 EUR 2023 EUR 2033
Through
Feed
1/2"(16C) EURC 2011 EURC 2021 EURC 2031
3/4"(22C) EURC 2012 EURC 2022 EURC 2032
1"(28C) EURC 2013 EURC 2023 EURC 2033
Plug & Receptacle
Copyright by NAMBUK Electric Co., LTD. 2004
Plugs And Receptacles
EDPR SeriesWeatherproof
<EDR>
<EDP>
Explosion-proof Back Box
Style
#1
28
1"
Style
#2
36
1-1/4"
Application
EDR Receptacles and EDP Plugs are
used ;
with portable electrically operated
devices such as motor generator
sets, compressors, conveyors,
portable tools, lighting systems and
similar equipment
in locations which are hazardous due
to the presence of combustible dusts
occuring in the processing and
handling of grain, flour and starch
in the 60 ampere, assemblies are
also suitable for use in areas which
are hazardous due to the presence
of flammable vapors or gases, as in
petroleum refineries, chemical and
petrochemical plants, and certain
process industry facilities.
Style
#3
42
1-1/2"
Explosion-proof Plug and Receptacle with Black
RatingNo. of
PoleHub Size
Recept.
Cat. No.
Nominal
Diameter
Of Cable
Plug
Cat. No
EDRB Recept.
With Back Box
Cat. No.
60A
220VAC
3wire
4pole
28 1"
EDR 1261
16 to 21 EDP 1261
EDRB 126136 1-1/4" 19 to 27 EDP 1262
42 1-1/2" 27 to 34 EDP 1263
60A
460VAC
3wire
4pole
28 1"
EDR 1461
16 to 21 EDP 1461
EDRB 146136 1-1/4" 19 to 27 EDP 1462
42 1-1/2" 27 to 34 EDP 1463
Dimension(mm)
EDR
EDP
Standard Materials
Back Boxes : Cast aluminium alloy
Receptacle housings And plug
exteriors : Cast aluminium alloy
Standard FinishMUNSELL No. 7.5BG 6/1.5
If you want another color, contact us
please.
Features
Construction of the receptacle permits the plug to be used as an emergency push-pull switch.EDR dead front receptacles are equipped with two separate contact assemblies. The rear contact assembly, to which field connections are made, is factory sealed to the housing. The movable front contact assembly, by virtur of its construction, provides an effective dust seal and, in the case of the 60 ampere unit a flametight joint as well.In operation, the plug must first be fully engaged with the front contact assembly, The plug may then be rotated clockwise and moved to engage the rear contact assembly.The plug cannot be withdrawn until the front contact assembly has been disengaged from the rear assembly and rotated counterclockwise to return it to the starting position.With this construction and operating sequence, the circuit making and breaking contacts are enclosed within a separate chamber, effectively sealed at both ends. Ignition of dust or flammable vapors or gases is prevented.The 30 and 60 ampere receptacles are provided with pressure terminals for field connection.As shown in the listings and dimensions, a selection of back boxes is offered to meet varied installation requirements.
Plug & Receptacle
Copyright by NAMBUK Electric Co., LTD. 2004
Plugs And Receptacles
EPR 20A Wet Locations
Type of Explosion-proof DimensionFlameproof-Increase Safety
(Ex de IIB T6)
< EPR 20A >
Conduit Size h
16(1/2") 17
22(3/4") 20
28(1") 23
Flameproof EPR Plugs and Receptacles Standard Materials
Switch Receptacle
Housing : Die casting aluminium
Terminal Box : Die casting aluminium
Plug Casing : Die casting aluminium
Conduit Entry Catalog No. Weight(Kg)Position Size
Terminal16(1/2") EPR 1011
4
22(3/4") EPR 101228(1") EPR 1013
Through-way16(1/2") EPR 1014
Specification22(3/4") EPR 101528(1") EPR 1016 Rated Voltage 250V AC
Rated Current 15-20A
Number of Pins 3 (2Pole+Earth)
* If you want 2 Gang, add suffix "2" to Cat. No. Example : EPR1011-2
Features
The flameproof enclosures of the switched receptacle are composed of the main body, barrier and terminal box,
putting one on another with spigot joints.
The interlocking device is of plug operation type. the built_in switch can only be operated by the plug in fully
engaged position, and the plug cannot be withdrawn unless the switch is in open position.
The plug is compact and complete flameproof, and incorporates a flameproof packing type cable gland.
The blanking cap is of spring-operated type and covers the receptacle outlet automatically when the plug is
withdrawn.
Selection Table of Rubber Packings for Cable Enteries*3 core 0.75mm222 Chloroprene
Sheathed Potable Power Cable can
be supplied in cut lengths to suit
customers' requirement
Packing No.Nominal Diameter
of Cable
Suitable Chlorprene Sheathed Portable
power Cable, Class 3
15S 13 to 15mm
16S 15 to 16mm 3 core 0.75 mm222
17S 16.5 to 17mm 3 core 2.0 mm222
These are the combinations of 15, 20Amperes rating
flameproof plugs and switched receptacles. Which contain
a toggle type switch. These plugs and receptacles are
designed mainly for connecting handlamps and other
portable small appliances to stationary supply-points.
The connector has three pins, but one pin is for earthing,
and these units are used only for single phase load.
Standard FinishMUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Plugs & Receptacle
Copyright by NAMBUK Electric Co., LTD. 2004
Plugs And Receptacles
EPR 30AWet Locations
Type of Explosion-proof
Flameproof-Increase Safety (Ex de IIB T6)
< EPR 30A (30 Type) >
Dimension(mm)
Selection Table of Rubber Packings for Cable Enteries Specification
Packing No.Nominal Diameter
of Cable
Suitable Chloroprene Sheathed Portable Power
Cable, Class 3
Rated Voltage 220V AC 460V ACRated Current 30A 30A
Number of Pins3(2-Pole+Earth) or
4(3-Pole+Earth)4(3-Pole+Earth)28-18 16 to 18mm 3 core 2.0mm222
Rated Interrupting
Capacity5KA at 220V AC 2.5KA at 460V AC28-20 18 to 20mm
3 core 3.5mm2 2 2
4 core 2.0mm222
28-21 20 to 21mm3 core 5.5mm2 2 2
4 core 3.5mm222Standard Materials
Switched Socket Housing : cast aluminium alloy
Terminal Box : cast aluminium alloy
Plug Casing : cast aluminium alloy
28-22 21 to 22mm3 core 8 mm2 2 2
4 core 5.5mm222
+Unless otherwise stated plugs are supplied with No. 28-21 packing
Standard FinishMUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Flameproof EPR Plugs and Receptacles with Circuit Breaker 30 Amps
Rated Voltage(V)
Conduit Entry Catalog No. Weight(Kg) *For EPR 3027
(460 volts
rating), specify
position and
size of conduit
entries when
ordering.
Position Size 3-Pin 4-Pin
220
Top22(3/4") EPR 3011 EPR 3021
9.228(1") EPR 3012 EPR 3022
Bottom22(3/4") EPR 3013 EPR 3023
9.228(1") EPR 3014 EPR 3024
Top and Bottom22(3/4") EPR 3015 EPR 3025
11.228(1") EPR 3016 EPR 3026
460 22(3/4"),28(1")Top, Bottom, or Top and Bottom - EPR 3027 11.2
These are the combination of 30 amperes rating flameproof plugs and switched receptacles which contain a circuit breaker. The 3-pin(2 Pole + Earth)units are used for single phase load, and 4-pin(3 Pole + Earth)units for three phase load. For 400 volts circuits, 4-pin plugs and receptacles carrying "460V" marking are also available, whose arrangement of pins is different from the standard units.
Features
The main enclosure of the switched receptacle has a socket outlet on the front cover and a operating handle on the side of the body. The terminal box is fitted to the top or bottom, or the both sides of the main body.The interlocking device is of handle operation type. The builtin circuit breaker is operated by the handle, and the plug can only be inserted or with drawn when the circuit breaker is in the open position.The plug is designed for heavy duty and incorporation a flameproof packing type cable gland.A screw-on blanking cap is provided for protecting the receptacle outlet.
Plug & Receptacle
Copyright by NAMBUK Electric Co., LTD. 2004
Plugs And Receptacles
EPR 30AWet Locations
Type of Explosion-proof
Flameproof-Increase Safety (Ex de IIB T6)
Specification
General Circuits Motor Protection
Rated Voltage 120, 240 or 460V AC 240 or 460V AC
Rated Current, or
Max. Motor output30A
2.5kW at 220V 11kW
at 440V
Number of Pins3 (2-Pole+Earth), or
4 (3-Pole+Earth)4 (3-Pole+Earth)
Operating time(max.) 100mS 100mS
Rated Interruptiong
Capacity2.5KA at 415V AC 2.5KA at 415V AC
< EPR 30A (31 Type) >
Dimension Standard MaterialsSwitched Receptacle Housing : Cast aluminium alloy
Terminal Box : Cast aluminium alloy
Plug Casing : Cast aluminium alloy
Standard FinishMUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Selection Table of Rubber Packings for Cable Entries
Packing
No.
Nominal Diameter
of Cable
Suitable Chloroprene Sheathed
Portable Power Cable, Class 3
28-18 16 to 18mm 3 core 2.0mm222
28-20 18 to 20mm 3 core 3.5mm2 2 2 4 core 2.0mm222
28-21 20 to 21mm 3 core 5.5mm2 2 2 4 core 3.5mm222
28-22 21 to 22mm 3 core 8 mm2 2 2 4 core 5.5mm222
Flameproof EPR Plugs and Receptacles with Circuit Breaker 30 Amps
Rated Voltage(V)
General Circuits 4-Pin Motor Protection 4-PinWeight(Kg)Rated
CurrentCatalog No.
Max. Motor Output (kW)
Catalog No.
120 30 EPR 3111 - -
10.5240 30 EPR 3112 5.5 EPR 3115
460 30 EPR 3113 11 EPR 3116
Conduit entry-28(1") max. at top and/or bottom. Specify the position and size when ordering.+ Form 'Motor Protection' unit, specify motor output as well.Note-receptacles of different voltage rating cannot be used in common. The applicable voltage ranges of these receptacles are 80-120V for 120V rating, 160-240V rating and 20-460V for rating.
These are the combination of 30 amperes rating flameproof plugs and switched receptacles which contain a circuit breaker. The 3-pin(2 Pole + Earth)units are used for single phase load, and 4-pin(3 Pole + Earth)units for three phase load. For 400 volts circuits, 4-pin plugs and receptacles carrying "460V" marking are also available, whose arrangement of pins is different from the standard units.
Plugs & Receptacle
Copyright by NAMBUK Electric Co., LTD. 2004
Plugs And Receptacles
EPR 100AWet Locations
Type of Explosion-proof
< EPR 100A >
Flameproof-Increase Safety (Ex de IIB T6)
Dimension
Flameproof EPR Plugs and Receptacles with Circuit Breaker 100 Amps
Standard MaterialsRated
Voltage
(V)
Rated
Current
(A)
Entry Position Catalog No. Weight(Kg) Switched Receptacle Housing :
cast aluminium ally
Terminal Box : cast aluminium ally
Plug Casing : cast aluminium ally
460AC
250DC
60
Top EPR 601154
Bottom EPR 6012
Top and Bottom EPR 6013 62Specification
75
Top EPR 750154
Rated Voltage 460V AC.250V DC
Rated Current 60, 75 or 100A
Number of Pins 5 (3Pole+E+N)
Rate interrupting 20KA A at 220V AC
Capacity 15KA A at 460V AC
10KA A at 250V DC
Bottom EPR 7502
Top and Bottom EPR 750362
100
Top EPR 10051
Bottom EPR 10052 54
Top and Bottom EPR 10053 62
Standard FinishMUNSELL No. 7.5BG 6/1.5
If you want another color, contact us
please.
Selection Table of Rubber Packings for Cable Enteries
Packing No.Nominal Diameter
of CableSuitable Chlorprene Sheathed Portable
power Cable, Class 3
54-37 33 to 37mm 4 core 22 mm222
54-41 37 to 41mm
54-44 41 to 44mm 4 core 38 mm222
* Unless otherwise stated plugs are supplied with No. 54-44 packing.
These are the combinations of 100amperes rating flameproof plugs and switched receptacles. Which contain a
circuit breaker, and used for movable large motors and welding units.
The construction and operation of these plugs and receptacles are mostly same as 30 amperes rating EPR Plugs
and Receptacle listed on page 79 except that the contacting part has more electrical capacity and different
mechanism.
Plug & Receptacle
Copyright by NAMBUK Electric Co., LTD. 2004
Plugs And Receptacles
EPRH 20A Wet Locations
Type of Explosion-proof DimensionFlameproof-Increase Safety
(Ex de IIC T6 IP55)
EPRH-P
EPRH-R
< EPRH 20A >
Conduit Size h
16(1/2") 17
22(3/4") 20
28(1") 23
Flameproof EPR Plugs and Receptacles Standard Materials
Conduit Entry Catalog No. Weight(Kg) Switch Receptacle
Housing : Die casting aluminium
Terminal Box : Die casting aluminium
Plug Casing : Die casting aluminium
Position Size
Terminal16(1/2") EPRH 1011
4
22(3/4") EPRH 101228(1") EPRH 1013
Through-way16(1/2") EPRH 1014
Specification22(3/4") EPRH 101528(1") EPRH 1016
Rated Voltage 250V AC
Rated Current 15-20A
Number of Pins 3 (2Pole+Earth)
Selection Table of Rubber Packings for Cable EnteriesStandard Finish
Packing No.Nominal Diameter
of Cable
Suitable Chloroprene Sheathed
Portable power Cable, Class 3 MUNSELL No. 7.5BG 6/1.5
If you want another color, contact
us please.15S 13 to 15mm
16S 15 to 16mm 3 core 0.75 mm222
17S 16.5 to 17mm 3 core 2.0 mm222
*3 core 0.75mm222 Chloroprene Sheathed Potable Power Cable can be
supplied in cut lengths to suit customers' requirement
These are the combinations of 15,
20Amperes rating flameproof plugs
and switched receptacles. Which
contain a toggle type switch. These
plugs and receptacles are designed
mainly for connecting handlamps
and other portable small appliances
to stationary supply-points.
The connector has three pins, but
one pin is for earthing, and these
units are used only for single
phase load.
Features
The flameproof enclosures of the switched receptacle are composed
of the main body, barrier and terminal box, putting one on another
with spigot joints.
The interlocking device is of plug operation type. the built_in switch
can only be operated by the plug in fully engaged position, and the
plug cannot be withdrawn unless the switch is in open position.
The plug is compact and complete flameproof, and incorporates a
flameproof packing type cable gland.
The blanking cap is of spring-operated type and covers the
receptacle outlet automatically when the plug is withdrawn.
Plugs & Receptacle
Copyright by NAMBUK Electric Co., LTD. 2004
Plugs And Receptacles
EPRH 100AWet Locations
Type of Explosion-proof Flameproof-Increase Safety
(Ex de IIC T6)
< EPRH 100A >
Dimension
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Flameproof EPR Plugs and Receptacles with Circuit Breaker 100 Amps
Standard MaterialsRated
Voltage
(V)
Rated
Current
(A)
Entry Position Catalog No. Weight(Kg) Switched Receptacle Housing :
cast aluminium ally
Terminal Box : cast aluminium ally
Plug Casing : cast aluminium ally
460AC
250DC
60
Top EPRH 601154
Bottom EPRH 6012
Top and Bottom EPRH 6013 62Specification
75
Top EPRH 750154
Rated Voltage 460V AC.250V DC
Rated Current 60, 75 or 100A
Number of Pins 4 (3-Pole+Earth)
Rate interrupting 20KA A at 220V AC
Capacity 15KA A at 460V AC
10KA A at 250V DC
Bottom EPRH 7502
Top and Bottom EPRH 7503 62
100
Top EPRH 1005154
Bottom EPRH 10052
Top and Bottom EPRH 10053 62
Selection Table of Rubber Packings for Cable Enteries
Packing No.Nominal Diameter
of CableSuitable Chloroprene Sheathed Portable
power Cable, Class 3
54-37 33 to 37mm 4 core 22 mm222
54-41 37 to 41mm
54-44 41 to 44mm 4 core 38 mm222
* Unless otherwise stated plugs are supplied with No. 54-44 packing.
These are the combinations of 100amperes rating flameproof plugs and switched receptacles. Which contain a
circuit breaker, and used for movable large motors and welding units.
The construction and operation of these plugs and receptacles are mostly same as 30 amperes rating EPR Plugs
and Receptacle listed on page 79 except that the contacting part has more electrical capacity and different
mechanism.
SECTION - 2P
Engineering Plastic
Plug & Receptacle
SECTION 2P
Engineering Plastic Plug & Receptacle INDEXModel Product Description
Certification for
Explosion-proofpage
EFPR 16A-NBEngineering Plastic Plug & Receptacle 16A
(NAMBUK Style)Ex de C T6 IP66Ⅱ 2P - 2
EFPR 16A Engineering Plastic Plug & Receptacle 16A Ex de C T6 IP66Ⅱ 2P - 3
EFPR 32A Engineering Plastic Plug & Receptacle 32A Ex de C T6 IP66Ⅱ 2P - 4
EFPR 63A Engineering Plastic Plug & Receptacle 63A Ex de C T6 IP66Ⅱ 2P - 5
EFPR 125A Engineering Plastic Plug & Receptacle 125A Ex de C T6 IP66Ⅱ 2P - 6
Plug & Receptacle
Copyright by NAMBUK Electric Co., LTD. 2004
Engineering Plastic Plugs & Receptacles
EFPR Series
Type of Explosion-proof Ex de IIC T6 IP66
Application Features
EFPR Series Plug & Receptacles are used in ;
heavy process industries having environments where
flammable or explosive vapors or gases, or where
combustible dusts are present.
petroleum refineries, chemical, petrochemical and
other heavy process industry facilities.
where ignitable concentrations of flammable gases,
vapors or liquids can exist some of the time under
normal operation conditions.
where ignitable concentrations of flammable gases,
vapors or liquids are not likely to exist under normal
operation conditions.
Enclosure in glass fiber reinforced polyester resin,
provide excellent resistant to corrosion so have a
long life.
Enclosure contain ultraviolet interception ingredient to
resist transformation.
Switches with large handles can be locked in 0 and
1 position.
Fully color-coded plug enclosure in color for voltage
and frequency.
Standard Materials
Housing : Glass fiber reinforced polyester resin
Gasket : Silicone rubber
External Hardware : Stainless steel, BrassStandard Finish
Natural
If you want another color, contact us please.
Swiching Capacity
Voltage
Cat. No. 220V- 230V- 240V- 380V- 400V- 415V- 500V- 660V- 690V-
EFPR 16A-NB 4KW - - -
EFPR 16A 4KW 7.5KW 11KW
EFPR 32A 7.5KW 15KW 18.5KW 30KW
EFPR 63A 18.5KW 30KW 37KW 55KW
If you need more information, contact us please. ⇨
Plug & Receptacle
Copyright by NAMBUK Electric Co., LTD. 2004
16A-NB Receptacle (NAMBUK Style)
Number of pins Voltage Color h Catalog No. Weight Certification
220 blue 6 EFPR 16A-NBR 1.3Kg
Ex de IIC
T6 IP66
16A-NB Plug (NAMBUK Style)
Number of pins Voltage Color h Catalog No. Weight Certification
220 blue 6 EFPR 16A-NBP 0.2Kg
Ex de IIC
T6 IP66
Dimension
EFPR 16A-NBR
EFPR 16A-NBR
EFPR 16A-NBP
Plug & Receptacle
Copyright by NAMBUK Electric Co., LTD. 2004
16A Receptacle
Number of pins Voltage Color h Catalog No. Weight Certification
110-130 yellow 4 EFPR 16A41R
3.7KgEx de IIC
T6 IP66
220-240 blue 9 EFPR 16A42R
380-400 red 6 EFPR 16A44R
500 black 7 EFPR 16A45R
660-690 black 5 EFPR 16A46R
110-130 yellow 4 EFPR 16A51R
220-240 blue 9 EFPR 16A52R
380-400 red 6 EFPR 16A54R
500 black 7 EFPR 16A55R
660-690 black 5 EFPR 16A56R
16A Plug
Number of pins Voltage Color h Catalog No. Weight Certification
110-130 yellow 4 EFPR 16A41P
0.29KgEx de IIC
T6 IP66
220-240 blue 9 EFPR 16A42P
380-400 red 6 EFPR 16A44P
500 black 7 EFPR 16A45P
660-690 black 5 EFPR 16A46P
110-130 yellow 4 EFPR 16A51P
220-240 blue 9 EFPR 16A52P
380-400 red 6 EFPR 16A54P
500 black 7 EFPR 16A55P
660-690 black 5 EFPR 16A56P
Dimension
EFPR 16A_R
EFPR 16A_R
EFPR 16A_P
Plug & Receptacle
Copyright by NAMBUK Electric Co., LTD. 2004
32A Receptacle
Number of pins Voltage Color h Catalog No. Weight Certification
110-130 yellow 4 EFPR 32A41R
Ex de IIC
T6 IP66
220-240 blue 9 EFPR 32A42R
380-400 red 6 EFPR 32A44R
500 black 7 EFPR 32A45R
660-690 black 5 EFPR 32A46R
110-130 yellow 4 EFPR 32A51R
220-240 blue 9 EFPR 32A52R
380-400 red 6 EFPR 32A54R
500 black 7 EFPR 32A55R
32A Plug
Number of pins Voltage Color h Catalog No. Weight Certification
110-130 yellow 4 EFPR 32A41P
Ex de IIC
T6 IP66
220-240 blue 9 EFPR 32A42P
380-400 red 6 EFPR 32A44P
500 black 7 EFPR 32A45P
660-690 black 5 EFPR 32A46P
110-130 yellow 4 EFPR 32A51P
220-240 blue 9 EFPR 32A52P
380-400 red 6 EFPR 32A54P
500 black 7 EFPR 32A55P
Dimension
EFPR 32A_R EFPR 32A_R
EFPR 32A_P
Plug & Receptacle
Copyright by NAMBUK Electric Co., LTD. 2004
63A Receptacle
Number of pins Voltage Color h Catalog No. Weight Certification
220-240 blue 9 EFPR 63A42R
Ex de IIC
T6 IP66
380-400 red 6 EFPR 63A44R
500 black 7 EFPR 63A45R
660-690 black 5 EFPR 63A46R
220-240 blue 9 EFPR 63A52R
380-400 red 6 EFPR 63A54R
500 black 7 EFPR 63A55R
63A Plug
Number of pins Voltage Color h Catalog No. Weight Certification
220-240 blue 9 EFPR 63A42P
Ex de IIC
T6 IP66
380-400 red 6 EFPR 63A44P
500 black 7 EFPR 63A45P
660-690 black 5 EFPR 63A46P
220-240 blue 9 EFPR 63A52P
380-400 red 6 EFPR 63A54P
500 black 7 EFPR 63A55P
Dimension
EFPR 63A_R EFPR 63A_R
EFPR 63A_P
Plug & Receptacle
Copyright by NAMBUK Electric Co., LTD. 2004
125A Receptacle
Number of pins Voltage Color h Catalog No. Weight Certification
220-240 blue 9 EFPR 125A42R
Ex de IIC
T6 IP66
380-400 red 6 EFPR 125A44R
500 black 7 EFPR 125A45R
220-240 blue 9 EFPR 125A52R
380-400 red 6 EFPR 125A54R
500 black 7 EFPR 125A55R
125A Plug
Number of pins Voltage Color h Catalog No. Weight Certification
220-240 blue 9 EFPR 125A42P
Ex de IIC
T6 IP66
380-400 red 6 EFPR 125A44P
500 black 7 EFPR 125A45P
220-240 blue 9 EFPR 125A52P
380-400 red 6 EFPR 125A54P
500 black 7 EFPR 125A55P
Dimension
Plug & Receptacle
Copyright by NAMBUK Electric Co., LTD. 2004
Technical Data
⁍ Receptacle
EFPR 16A-NB EFPR 16A EFPR 32A EFPR 63A EFPR 125A
Rated Voltage 220V + 5% ...690V + 5% ...690V + 5% ...690V + 5% ...690V + 5%
Rated Current 16A 16A 32A 63A 125A
Interlock Switch3 pole switch with isolating characteristics 1 auxiliary contact
(ON-delayed, OFF-advanced)
Terminal 4 X 2㎟ 4 X 2㎟ 10 X 2㎟ 35 X 1㎟ 120 X 1㎟
Ambient Temperature -20 ...+40℃ ℃ -20 ...+40℃ ℃ -20 ...+40℃ ℃ -20 ...+40℃ ℃ -20 ...+40℃ ℃
Hub bottom 1 X M25 bottom 1 X M25 bottom 1 X M32 bottom 1 X M50 bottom 1 X M63
Stopping Plug bottom 1 X M25 bottom 1 X M25 bottom 1 X M32 bottom 1 X M25 bottom 1 X M63
⁍ Plug
Terminal 4 ㎟ 4 ㎟ 10 ㎟ 16 ㎟ 35 ㎟
Cable Entry Max. Ø21㎜ Max. Ø21㎜ Max. Ø28㎜ Max. Ø36㎜ Max. Ø50㎜
⁍ Color and Arrangement
Operating Voltage
(V)
Frequency
(Hz)Color
h-position
3P 4P 5P
110-130 50/60 Yellow 4 4 4
220-240 50/60 Blue 6 9 9
380-400 50/60 Red 9 6 6
500 50/60 Black 7 7 7
660-690 50/60 Black - 5 5
Position Clockwise Front view of Plug
⁍ Accessories and Spare parts
Designation Description Catalog No.
Switch for Receptacle EFPR 16A-NB EFSS 16-NB
EFPR 16A EFSS 16
EFPR 32A EFSS 32
EFPR 63A EFSS 63
Protection cap for Plug EFPR 16A-NB 3P EFPC 163
EFPR 16A 4P EFPC 164
EFPR 16A 5P EFPC 165
EFPR 32A 4P EFPC 324
EFPR 32A 5P EFPC 325
EFPR 63A 4/5P EFPC 634
SECTION - 1F
Junction Box
SECTION 1F
Junction Boxes INDEX
Model Product DescriptionCertification for Explosion-proof
Page
IEC UL
SBD Increase Safety Junction Boxes Ex e Ⅱ 1F - 1
EOB Flameproof Junction Boxes Ex d II C
Class I
Group C,D
Class II
Group E,F,G
1F - 2
EOS Junction Boxes with Union Hubs Ex d CⅡ 1F - 3
WAB Increase Safety Junction BoxesEx e II T6
Ex DP II 131F - 4
SWAB Increase Safety Junction Boxes Ex e II T6 1F - 5
EFCS-T Engineering Plastic Terminal Box Ex e II T6 IP66 1F - 6
EJG Flameproof Junction Boxes Ex d IIC T6 Ex d IIC T6 1F - 8
EBGC Flameproof Junction Boxes Ex d IIB T6 1F - 10
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
Conduit SizeDimension
A B C D16 ½" 127 89 62 115
22 ¾" 127 89 62 115
28 1" 141 89 66 122
36 1¼" 170 106 90 148
42 1½" 170 106 90 148
54 2" 204 124 120 182
Application
SBD junction boxes are used ;
in originally designed for humid or dusty locations.
together with the SD Elbows shown on page
because of their higher quality on strength, dustproof
and weatherproof.
they are used securely for conduit wiring in Division
2 hazardous areas.
in select the proper entry position and size of box in
accordance with the location and the use.
Features
These boxes of conduit sized 16(1/2"), 22(3/4"), and
28(1") can be used for the mounting box of
increased safety SYL Incandescent and SYFL
Fluorescent Lighting Fittings, and vapour-tight VDY
Incandescent Lighting Fittings.
Standard Materials
Cast Iron
Cast Aluminium
Standard Finish
Hot Dip Galvanized with stove enamelled
Cast Al : MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
If you need more information, contact us please.⇨
Ordering Number
<Dimension> EntriesConduit
Size
Catalog
NumberWeight
( )㎏Flat Cover
Terminal
16 1/2" SBD1016 1.8
22 3/4" SBD1022 1.8
28 1" SBD1028 2.0
36 1-1/4" SBD1036 3.5
42 1-1/2" SBD1042 3.9
54 2" SBD1054 5.5
Through
-Way
16 1/2" SBD2116 1.8
22 3/4" SBD2122 1.8
28 1" SBD2128 2.0
36 1-1/4" SBD2136 3.4
42 1-1/2" SBD2142 3.8
54 2" SBD2154 5.4
Angle
16 1/2" SBD2216 1.7
22 3/4" SBD2222 1.7
28 1" SBD2228 1.9
36 1-1/4" SBD2236 3.3
42 1-1/2" SBD2242 3.6
54 2" SBD2254 5.2
Three
-Way
16 1/2" SBD3016 1.8
22 3/4" SBD3022 1.8
28 1" SBD3028 2.0
36 1-1/4" SBD3036 3.5
42 1-1/2" SBD3042 3.9
54 2" SBD3054 5.5
Four
-Way
16 1/2" SBD4022 1.7
22 3/4" SBD4028 1.7
28 1" SBD4036 1.9
36 1-1/4" SBD4042 3.4
42 1-1/2" SBD4054 3.7
54 2" SBD4054 5.3
Compliance
IEC 60079-0, 7
Certification
Certified by KOSHA (Korea Occupational Safety &Health Agency), KGS (Korea Gas SafetyCorporation), and the others.
Increase Safety Junction Boxes
SBD Series
Type of Explosion-proof
Increase Safety ( Ex e II )
< SBD >
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
Flameproof Junction Boxes
EOB Series
Type of Explosion-proof Ordering Number
<Dimension> EntryConduit
Size
Catalog NumberWeight
( )㎏
Flameproof ( Ex d IIC )
Class I Group C,D Class II Group E,F,GFlat
Cover
Dome
Cover
Terminal
16 1/2" EOB1016 EOBD1016 1.8
22 3/4" EOB1022 EOBD1022 1.8
< EOB >
28 1" EOB1028 EOBD1028 2.0
36 1-1/4" EOB1036 EOBD1036 3.5
42 1-1/2" EOB1042 EOBD1042 3.9
54 2" EOB1054 EOBD1054 5.5
Through-Way
16 1/2" EOB2116 EOBD2116 1.8
22 3/4" EOB2122 EOBD2122 1.8
28 1" EOB2128 EOBD2128 2.0
36 1-1/4" EOB2136 EOBD2136 3.4
42 1-1/2" EOB2142 EOBD2142 3.8
54 2" EOB2154 EOBD2154 5.4
Angle
16 1/2" EOB2216 EOBD2216 1.7Conduit Size
Dimension
22 3/4" EOB2222 EOBD2222 1.7A B C D E F
28 1" EOB2228 EOBD2228 1.916 1/2" 85 132 79 8 116 116
36 1-1/4" EOB2236 EOBD2236 3.322 3/4" 85 132 82 8 116 116
42 1-1/2" EOB2242 EOBD2242 3.628 1" 85 142 86 8 121 121
54 2" EOB2254 EOBD2254 5.236 1-1/4" 106 170 96 10 148 148
42 1-1/2" 106 170 102 10 148 148
Three-Way
16 1/2" EOB3016 EOBD3016 1.8
54 2" 142 234 164 10 198 198 22 3/4" EOB3022 EOBD3022 1.8
28 1" EOB3028 EOBD3028 2.0
Application 36 1-1/4" EOB3036 EOBD3036 3.5
42 1-1/2" EOB3042 EOBD3042 3.9EOB junction boxes are used ;in indispensable for splicing and branching ofconductors for electrical wiring in explosive gasatmosphere.in various products in accordance with applicableconduit sizes and positions of entries are supplied asstandard.in select suitable type and dimensions according tothe location.
54 2" EOB3054 EOBD3054 5.5
Four-Way
16 1/2" EOB4022 EOBD4022 1.7
22 3/4" EOB4028 EOBD4028 1.7
28 1" EOB4036 EOBD4036 1.9
36 1-1/4" EOB4042 EOBD4042 3.4
42 1-1/2" EOB4054 EOBD4054 3.7
54 2" EOB4054 EOBD4054 5.3
Compliance CertificationFeatures
IEC 60079-0, 1
ANSI/UL 886
ANSI/UL 514A
Certified by KOSHA (KoreaOccupational Safety &Health Agency), KGS (KoreaGas Safety Corporation),and the others.
The cover is ;Thread-jointed to the bodySynthetic rubber O-ring is used outside of the joint.Assured flameproof, weatherproof and dust-tight areobtained.When the connections of conductors are bulky or thetreatment of wiring is difficult.Recommend to use the EOBD Junction Boxes withdome cover.
Dome Cover
Standard Materials
Cast Iron
If you want another color, contact us please.
The dome cover can be fitted with the splices ofconductors standing as shown in the photograph.Splicings and treatments of many conductors caneasily be done without suffering damages in theboxes.
Standard Finish
Cast Iron : Hot Dip Galvanized with stove enamelledCast Al : MUNSELL No. 7.5BG 6/1.5If you want another color, contact us please.
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
Junction Boxes with Union Hubs
EOS Series
Type of Explosion-proof
Flameproof ( Ex d IIC )
Dimension
< EOS >
Application Features Compliance & Certification
EOS Series junction boxes with
union hubs are used ;
in Threaded rigid conduit
systems in hazardous areas
to allow easy disassembly of
conduit system
to function as junction and pull
box for multiple conductors and
conduits
in Indoors or outdoors where
space is limited, such as in
gasoline pumps
Supplied with union hubs which
makes it a compact assembly
Have a variety of hub
arrangements
Covers are threaded
Mounting straps are standard on
all boxes
IEC 60079-0, 1
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Size Range
1/2" ~ 1" Hub
Standard MaterialsStandard FinishBody : Cast Iron
Cover : Cast Aluminium Alloy Cast Iron : Hot Dip Galvanized
with stove enamelled
Cast Al : MUNSELL NO.7.5BG
6/1.5
Ordering Number Ordering InformationHub Size Ordering Number
A B C D E with Nuts and Sleeves
1/2" 1/2" 1/2" EOS 3000
3/4" 3/4" 3/4" EOS 3111
1/2" 3/4" 3/4" EOS 3011
3/4" 1/2" 1/2" EOS 3100
3/4" 1" 1" EOS 3122
3/4" 1" 3/4" EOS 3121
1"3/4" 3/4" EOS 3211
1"3/4" 1" EOS 3212
1"1" 1" EOS 3222
3/4" 3/4" 3/4" 3/4" EOS 41111
3/4" 3/4" 3/4" 3/4" 3/4"EOS 511111
EOS 5 11111
EO S 4 11 11① ② ③
: EOS Junction Box①
: Nos. of Hub②
: Hub Size③
0 : 1/2"
1 : 3/4"
2 : 1"
(Marking In order of top left to top right, bottom
left to bottom right)
If you need more information, contact us please.⇨
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
Increase Safety Junction Boxes
WAB Series
Type of Explosion-proof
Increase Safety ( Ex e II T6)
Dust Ignition-proof (Ex DP II 13)
Application Features
Flat neoprene gasket cemented to cover.Wide range of drilled and tapped and slip holeconduit entrance sizes and locations permitsmaximum flexibility of use in conduit system.Choice of locations for holes blind tapped intointernal mounting pads.
Where a heavy duty dust-tight or Weatherproof enclosureis desired, WAB boxes are installed in conduit systems to ;act as pull box for conductors.provide Openings and space for making splices andtaps in conductors.provide access to conductors for maintenance andfuture system changes.
Compliance& CertificationStandard Materials IEC 60079-0, 7
Certified by KOSHA (Korea Occupational Safety &Health Agency), KGS (Korea Gas SafetyCorporation), and the others.
Cover and Body : Cast aluminium alloyNeoprene gasketsStainless steel cover screws
Standard FinishOptions
Drain plug & Breather MUNSELL No. 7.5BG 6/1.5if you want another color, contact us please.
< WAB >
CatalogNumber
Max. conduitsize
Max. No ofTerminals
A B C D E F∅WAB040403 28 1" Max. 2.5mm2 × 8P 120 120 145 70 80 2- 8∅WAB060604 28 1" Max. 2.5mm2 × 10P 180 180 200 100 120 2- 10∅WAB080804 28 1" Max. 2.5mm2 × 20P 230 230 260 140 120 4- 10∅WAB080808 42 1-1/2" Max. 2.5mm2 × 20P 230 230 260 140 225 4- 10∅WAB100808 42 1-1/2" Max. 2.5mm2 × 40P 230 280 260 200 225 4- 10∅WAB121008 42 1-1/2" Max. 2.5mm2 × 60P 285 340 320 210 230 4- 12∅WAB121010 42 1-1/2" Max. 2.5mm2 × 60P 285 340 320 210 280 4- 12∅WAB121208 54 2" Max. 2.5mm2 × 60P 335 335 370 210 240 4- 12∅WAB121210 54 2" Max. 2.5mm2 × 60P 335 335 370 210 280 4- 12∅WAB141408 70 2-1/2" Max. 2.5mm2 × 60P 385 385 420 260 230 4- 12∅WAB141410 70 2-1/2" Max. 2.5mm2 × 60P 385 385 420 260 280 4- 12∅WAB161008 70 2-1/2" Max. 2.5mm2 × 60P 270 425 300 360 245 4- 12∅WAB161010 70 2-1/2" Max. 2.5mm2 × 60P 270 425 300 360 285 4- 12∅WAB241408 82 3" Max. 2.5mm2 × 100P 325 630 350 570 250 4- 12∅WAB241410 82 3" Max. 2.5mm2 × 100P 325 630 350 570 285 4- 12∅WAB242008 82 3" Max. 2.5mm2 × 250P 630 540 665 480 240 4- 12∅WAB281408 104 4" Max. 2.5mm2 × 120P 385 740 415 680 285 4- 15∅WAB351408 104 4" Max. 2.5mm2 × 120P 385 920 415 680 230 4- 18∅WAB353311 104 4" Max. 1000A 900 850 950 800 325 4- 18∅
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
Increase Safety Junction Boxes
SWAB Series
Type of Explosion-proofRating Max. 600V◎
IP Rating : IP65◎Increase Safety (Ex e II T6)
Application Features
Flat neoprene gasket cemented to cover.
Wide range of drilled and tapped and slip hole
conduit entrance sizes and locations permits
maximum flexibility of use in conduit system.
Choice of locations for holes blind tapped into
internal mounting pads.
Where a heavy duty dust-tight or weatherproof enclosure
is desired, SWAB boxes are installed in conduit systems
to ;
act as pull box for conductors.
provide Openings and space for making splices and
taps in conductors.
provide access to conductors for maintenance and
future system changes.
enclose and protect electrical device.
Compliance& CertificationStandard Materials IEC 60079-0, 7
Certified by KOSHA (Korea Occupational Safety &
Health Agency), KGS (Korea Gas Safety
Corporation), and the others.
Cover and Body : Stainless steel
Neoprene gaskets
Cover bolts, door handle : Stainless steelOptions
Terminals can fitted to order.
Cable glands can fitted to order.
Sockets can fitted to order.Standard Finish
Natural
If you want another color, contact us please. Dimension
< SWAB >
Catalog Number Nos. of TerminalDimension (mm)
DEPTHA B C D
SWAB 303020 Max. 20p 300 300 200 340
200
SWAB 353520 Max. 40p 350 350 250 390
SWAB 404020 Max. 40p 400 400 300 440
SWAB 505020 Max. 80p 500 500 400 540
SWAB 616120 Max. 160p 610 610 510 650
* Above nos. of terminal are standard. For example SWAB 353520 can install 80p of
terminal, but T glade is lower then. If you want more terminals, contact us.
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
Engineering Plastic Terminal Box
EFCS-T Series
Type of Explosion-proofIncrease Safety (Ex e II T6 IP66)
Application Features
EFCS-T Series Terminal Boxes are used ;
in Heavy process industries having environments
where flammable or explosive vapors or gases, or
where combustible dusts are present
in Petroleum refineries, chemical, petrochemical and
other heavy process industry facilities
where ignitable concentrations of flammable gases,
vapors or liquids can exist some of the time under
normal operation conditions.
where ignitable concentrations of flammable gases,
vapors or liquids are not likely to exist under normal
operation conditions.
where combustible dust, moisture, dirt are present
and vibration, corrosion, rough usage are problems
Enclosure in glass fiber reinforced polyester resin,
provide excellent resistant to corrosion so have a
long life.
Enclosure contain ultraviolet interception ingredient to
resist transformation.
Easy installation and maintenance
Metal cable entries can be fitted. They are crewed
into brass plates and via these incorporated into the
earthing system of the enclosure.
Standard Materials
Housing, mounting modules, component pallets :
Glass fiber reinforced polyester resin
Gasket : Silicone rubber
External Hardware : Stainless steel, Brass
Terminal : increase safety type
(standard : WDU Series (Weidmuller))
Options
Terminals can fitted to order.
Cable glands can fitted to order.
Sockets can fitted to order.
( Suffix : SC )Standard Finish
Natural
If you want another color, contact us please.
If you need more information, contact us please.⇨
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
Technical Data
Terminal Catalog No.
Type Size ( )㎟ Current(A) EFCS 1200T EFCS 2800T EFCS 5542T
Max. No. of Terminals
(P)
WDU 2.5 2 25 40 60 120
WDU 4 3.5 35 40 60 120
WDU 6 5.5 45 30 30 60
WDU 10 8 60 20 20 40
RatingMax. 550V,
40P
Max. 550V,
80P
Max. 550V,
120P
Max. No. of Cable Gland
1/2" 22Ø 6 6 18
1" 28Ø 4 4 12
1-1/2" 36Ø (3) 4 10
1-1/2" 42Ø (3) (3) 6
2“54Ø - - 6 -
2-1/2" 70Ø - - 4
3“82Ø - - 2 -
4“104Ø - - 2 -
Dimension (mm)
A 342 342 550
B 172 342 420
C 100 100 200
Certification Ex e II T6 IP66
-
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
Flameproof Junction Boxes
EJG Series
Wet Locations
Raintight
NEMA 4,7,9
<EJG 20> <EJG 30> <Self Standing>
Type of Explosion-proofFlameproof (Ex d IIC T6)
Features Standard MaterialsApplication
Threaded construction
throughout permits use in
hazardous areas
Wide variety of conduit hub
arrangements
Hubs provide integral bushings
Covers are sealed with optional
"O"ring gasket when watertight
enclosures are required
Internal grounding lug provides
a means to ground enclosed
equipment
Body : Cast aluminium alloy
Cover : Cast aluminium alloyEJG series Junction boxes are used ;
in threaded rigid conduit system in
hazardous areas
to function as a splice box, pull
box or equipment and device
enclosure
in Indoors and outdoors
Compliance & Certification
IEC 60079-0, 1
UL Listed File No.
Certified by UL (Underwriters
Laboratories Inc.), KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Standard Finish
Zinc chromated
MUNSELL No. 7.5BG 6/1.5
Threaded Covers for EJG Junction Boxes
Flat Cover
Glass Cover
Dome Covers
Application FeaturesEJG threaded covers are used ;
with EJG boxes in control
systems in hazardous areas
Indoors and outdoors
In three categories :
+Flat - for normal use :
furnished with standard EJG
boxes
+Glass window - to provide
visibility of meter indications
when used to enclose meters
+Domed - for increasing
volume of EJG to make it
easier to splice and pull large
conductors
Domed - more suitable for use
when splices of heavy
conductors are made and
enclosed, since the conductors
may be pulled in with the ends
outside the box. After the splices
are made, they do not have to
be crowded back into the box
Glass window has maximum
diameter glass to give best
visibility. In selecting, the
diameter of the meter face
should match or be slightly
smaller than window diameter
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Standard Materials
Cast aluminium alloy
⇨ Flat cover is standard. Suffix GC for Glass Cover, and DC for Dome Cover. ex) EJG 21 DC
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
Body Dimension
EJG 20 EJG 30 Self Standing TypeCATALOG
NO.
DIMENSIONS (mm)
A B C D E F
EJG 10
Series
EJG 11 118 118 118 - - -
EJG 12 130 130 87 - - -
EJG 13 145 145 131 113 170 10
EJG 20
Series
EJG 20 157 157 130 113 180 10
EJG 21 165 178 140 146 190 10
EJG 22 203 254 150 222 228 10
EJG 23 216 254 180 222 240 10
* EJG 23S 216 254 180 63 245 10
EJG 30
Series
EJG 31 280 305 240 260 308 12
* EJG 31S 280 305 240 89 308 12
EJG 32 357 459 343 407 386 12
EJG 33 480 530 430 457 534 13
EJG 23S, 31S are Self Standing Type.※
Cover DimensionCover
For Body
EJG DC Dim.(mm) EJG GC Dim.(mm)
EJG GC(Glass Cover)
A B C A B C
EJG 21 120 70 102159 50 90
EJG 21* 120 232 264
EJG 22 166 130 172 209 55 120
EJG 23 / 23S 166 130 172 209 55 120
EJG 31 228 203 266280 50 172
EJG 31S 228 388 442
EJG 32 300 90 166 - - -
EJG 33 300 370 446 - - -
* Suffix DCL when order large size dome cover in EJG 21 body.
EJG DC(Dome Cover)
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
Flameproof Junction Boxes
EBGC Series
Type of Explosion-proofFlameproof (Ex d IIB T6) Dimension
< EBGC >
Application Features
EBGC junction boxes are used ;
in threaded rigid conduit systems in hazardous areas;
as a junction or pull box
to provide enclosures for splices and branch circuit taps
for housing terminal blocks, relays and other electrical
devices
in Indoor or outdoor in damp, wet, dusty, corrosive,
hazardous locations
where exposure to frequent or heavy rain, water, spray,
moisture, and humidity is common; such as : offshore
drilling facilities, cooling towers, coal preparation and
handling facilities and sewage and waste water treatment
plant
in areas which are hazardous due to the presence of
gases and vapors of equivalent hazard such as found in
process industries and gas manufacturing plants
Ground joint cover opening provides maximum
opening for pulling wires or mounting equipment.
Walls of selected bodies may be drilled and tapped
for conduit entries
Flat cover provides additional space for mounting a
greater number of control devices.
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Standard Materials
Body & Cover : Cast aluminium alloy
CertificationCompliance
Certified by KOSHA (Korea Occupational Safety &
Health Agency), KGS (Korea Gas Safety
Corporation), and the others.
IEC 60079-0, 1
IP 55
IP 65 (Order made)
Explosion Proof EBGC Junction Boxes
Catalog No.Max. Conduit
Size
Max. No. of
TerminalsA B C D E F G
EBGC 91 42 1-1/2" 20P 290 170 260 200 145 155 11
EBGC 92 42 1-1/2" 30P 300 260 270 300 145 155 11
EBGC 93 42 1-1/2" 30P 320 300 280 340 145 155 11
EBGC 94 54 2" 60P 380 260 340 300 175 190 11
EBGC 95 54 2" 80P 460 330 420 360 175 190 11
EBGC 96 70 2-1/2" 80P 560 350 500 400 205 220 17
EBGC 97 70 2-1/2" 80P 500 500 460 550 205 220 17
EBGC 98 82 3" 120P 750 500 690 550 250 270 17
EBGC 100 104 4" 3P (500A) 1000 600 600 680 500 500 25
If you need more information, contact us please.⇨
SECTION - 2F
Elbow & Union
SECTION 2F
Elbows & Union INDEX
Model Product DescriptionCertification for Explosion-proof
Page
IEC UL
EXY Elbow Ex d CⅡClass Group C,D Ⅰ
Class Group E,F,GⅡ2F - 1
EXA Elbow Ex d CⅡ 2F - 2
EXT Elbow Ex d CⅡ 2F - 2
EFA Elbow Ex d BⅡ 2F - 2
ELZ Elbow Ex d CⅡ 2F - 3
SDC Conduit Body Ex e II 2F - 5
SDLB Conduit Body Ex e II 2F - 5
SDLL Conduit Body Ex e II 2F - 5
SDLR Conduit Body Ex e II 2F - 6
SDT Conduit Body Ex e II 2F - 6
SDTB Conduit Body Ex e II 2F - 6
SDX Conduit Body Ex e II 2F - 7
EUX Union Ex d IIC
Class I Group C,D
Class II Group
E,F,G
2F - 8
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
Elbow & Union
Elbow Series
Application
These Elbows are used in ;
act as pull outlet.
provide access to conductors for maintenance and
future system changes.
make 90° bends in conduits system where space is
limited.
provide access to wiring for maintenance and future
system changes.
allow single conduit stub up to outlet and device
boxes located above or below min conduit runs.
where ignitable concentrations of flammable gases,
vapors or liquids can exist some of the time under
normal operation conditions.
Compliance& Certification
IEC 60079-0, IEC 60079-1
ANSI/UL 886
Certified by UL (Underwriters Laboratories Inc.),
KOSHA (Korea Occupational Safety & Health Agency),
KGS (Korea Gas Safety Corporation), and the others. Features
Cover openings on an angle, permitting conductors
to be pulled straight through either hub.
Taper tapped hubs and integral bushing for rigid
threaded conduit.
Maximum volume for bends within a compact
overall size.
Domed covers to permit easy conductor bends.
Screw on cover for ease of installation and removal
UL Listed File No. E143517 (EXY series).
Standard Materials
Body : Cast Iron
Cover : Cast Iron
Standard Finish
Hot Dip. Galvanized with stove enamelled
If you want another color, contact us please.
Options
NPT Thread : suffix. NPT
Type of Explosion-proof
◎ EXYFlameproof ( Ex d IIC)
Class I Group C,D Class II Group E,F,G
Hub Size1/2"
16C
3/4"
22C
1"
28C
1-1/4"
36C
1-1/2"
42C
2"
54C
2-1/2"
70C
3"
82C
Cat. No. EXY1100 EXY1111 EXY1122 EXY1133 EXY1144 EXY1155 EXY1166 EXY1177
Dimension
a 64 57 64 83 85 102 138 138
b 71 75 93 104 114 132 138 138
c 90 88 115 136 148 167 218 237
d 84 90 102 115 126 144 187 200
If you need more information, contact us please. ⇨
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
◎ EXA Type of Explosion-proof
Flameproof ( Ex d IIC)
Hub Size1/2"
16C
3/4"
22C
1"
28C
1-1/4"
36C
1-1/2"
42C
2"
54C
2-1/2"
70C
3"
82C
Cat. No. EXA1200 EXA1211 EXA1222 EXA1233 EXA1244 EXA1255 EXA1266 EXA1277
Dimension
a 65 65 65 85 85 102 138 138
b 60 70 74 96 105 114 134 147
c 80 83 84 105 113 130 166 180
◎ EXT Type of Explosion-proof
Flameproof ( Ex d IIC)
Hub Size1/2"
16C
3/4"
22C
1"
28C
1-1/4"
36C
1-1/2"
42C
2"
54C
2-1/2"
70C
3"
82C
Cat. No. EXT1300 EXT1311 EXT1322 EXT1333 EXT1344 EXT1355 EXT1366 EXT1377
Dimension
a 65 65 65 85 85 102 138 138
b 60 70 74 100 105 114 134 147
c 95 101 103 125 142 158 216 240
d 80 83 84 105 113 130 166 180
◎ EFA Type of Explosion-proof Flameproof ( Ex d IIB)
Hub Size1/2"
16C
3/4"
22C
1"
28C
1-1/4"
36C
1-1/2"
42C
2"
54C
2-1/2"
70C
3"
82C
Cat. No. EFA 140 EFA 141 EFA 142 EFA 143 EFA 144 EFA 145 EFA 146 EFA 147
Dimension
a 128 128 200 200 270 270 400 400
b 66 66 86 86 114 114 140 140
c 101 101 130 130 175 175 240 240
d 78 78 98 98 124 124 144 144
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
◎ ELZ Type of Explosion-proof
Flameproof ( Ex d IIC)
TypeHub
SizeCat. No.
Dimen.
A B
90°
Male
1/2" 16C ELZ 9016 35 35
3/4" 22C ELZ 9022 42 42
1" 28C ELZ 9028 51 51
1-1/4" 36C ELZ 9036 54 54
1-1/2" 42C ELZ 9042 - -
2" 54C ELZ 9054 - -
90°
Female
1/2" 16C ELZF 9016 38 38
3/4" 22C ELZF 9022 45 45
1" 28C ELZF 9028 51 51
1-1/4" 36C ELZF 9036 57 57
1-1/2" 42C ELZF 9042 102 102
2" 54C ELZF 9054 127 127
45°
Female
1/2" 16C ELZ 4516 30 30
3/4" 22C ELZ 4522 35 35
1" 28C ELZ 4528 42 42
1-1/4" 36C ELZ 4536 45 45
1-1/2" 42C ELZ 4542 49 49
2" 54C ELZ 4554 58 58
90°
Male &
Female
1/2" 16C ELZMF 9016 35 35
3/4" 22C ELZMF 9022 45 42
1" 28C ELZMF 9028 51 51
1-1/4" 36C ELZMF 9036 57 57
1-1/2" 42C ELZMF 9042 102 98
2" 54C ELZMF 9054 127 120
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
Elbow & Union
SD Conduit Body Series
Type of Explosion-proof
Increase Safety ( Ex e II )
Application
SD Series Conduit bodies are installed in;
act as pull outlet bodies for conductors being
installed.
provide openings for making splices and taps in
conductors.
act as mounting outlets for lighting fixtures and wiring
devices.
connect conduit sections.
provide taps for branch conduit runs.
make 90° bends in conduit runs.
provide for access to conductors for maintenance and
future system changes.
where ignitable concentrations of flammable gases,
vapors or liquids can exist some of the time under
normal operation conditions. Standard Materials
Body : Cast Iron
Cover : Cast Iron
Gasket : Neoprene
Features Standard Finish
2 product sizes (Large, Middle).
7 shapes (C, LB, LL, LR, T, TB, X).
10 conduit sizes (1/2, 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3,
3-1/2, 4").
SD-M series conduit bodies approach conduit in size
for neat, compact installations.
SD-L series conduit bodies provide more room for
heavier conductors.
SD-L series conduit bodies are standard products.
Most of SD-L series conduit bodies get UL
Certification.
Conduit hubs have tapered threads and feature
integral bushings for protection of wire insulation.
Smooth integral wire bushings protects cable form
damage when wires are pulled through opening.
Solid gaskets or Open gaskets
Hot Dip. Galvanized with stove enamelled silver
white
If you want another color, contact us please.
OptionNPT Thread : suffix. NPT
Compliance
IEC 60079-0, 7
ANSI/UL 886
UL Listed File No. E142233
Certification
Certified by UL (Underwriters Laboratories Inc.),
KOSHA (Korea Occupational Safety & Health
Agency), KGS (Korea Gas Safety Corporation), and
the others.
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
C Type
Hub
Size
1/2"
16C
3/4"
22C
1"
28C
1-1/4"
36C
1-1/2"
42C
2"
54C
2-1/2"
70C
3"
82C
3-1/2"
92C
4"
104C
Cat. No.SDC
510M
SDC
511M
SDC
512M
SDC
513M
SDC
514M
SDC
515M
SDC
516M
SDC
517M
SDC
518M
SDC
519M
Dimen
sion
a 137 152 178 196 210 235 302 302 360 360
b 35 40 45 58 64 75 108 108 134 134
c 35 42 48 59 66 80 94 113 127 140
d 25 29 33 45 51 61 90 90 114 114
e 66 82 98 105 116 136 171 171 200 200
Cat. No.SDC
510L
SDC
511L
SDC
512L
SDC
513L
SDC
514L
SDC
515L
SDC
516L
SDC
517L- -
Dimen
sion
a 145 169 201 218 252 306 396 396 - -
b 34 45 48 58 69 95 124 124 - -
c 37 53.5 58 66 74 90 113 122 - -
d 25 32 35 44 52 76 110 110 - -
e 80 96 110 127 157 210 276 276 - -
LB Type
Hub
Size
1/2"
16C
3/4"
22C
1"
28C
1-1/4"
36C
1-1/2"
42C
2"
54C
2-1/2"
70C
3"
82C
3-1/2"
92C
4"
104C
Cat.
No.SDLB
520M
SDLB
521M
SDLB
522M
SDLB
523M
SDLB
524M
SDLB
525M
SDLB
526M
SDLB
527M
SDLB
528M
SDLB
529M
Dime
nsion
a 115.5 132 155 172 184.5 208.5 267 267 322 322
b 35 40 45 58 64 75 108 108 134 134
c 55 62 71.5 84.5 93.5 110.5 130 149 167 180
d 25 29 33 45 51 61 90 90 114 114
e 66 82 98 105 116 136 171 171 200 200
Cat. No.SDLB
520L
SDLB
521L
SDLB
522L
SDLB
523L
SDLB
524L
SDLB
525L
SDLB
526L
SDLB
527L
SDLB
528L
SDLB
529L
Dime
nsion
a 130 150 175.5 195 225 283 356 356 428 428
b 37 45 48 58 68 96 130 130 162 162
c 55 69 82 85.5 102 130 155.5 165 192 198.5
d 25 32 35 44 52 76 110 110 140 140
e 80 96 110 127 153 206 276 276 330 330
LL Type
Hub
Size
1/2"
16C
3/4"
22C
1"
28C
1-1/4"
36C
1-1/2"
42C
2"
54C
2-1/2"
70C
3"
82C
3-1/2"
92C
4"
104C
Cat. No.
SDLL 520M
SDLL 521M
SDLL 522M
SDLL 523M
SDLL 524M
SDLL 525M
SDLL 526M
SDLL 527M
SDLL 528M
SDLL 529M
Dimen
sion
a 115.5 132 155 172 184.5 208.5 267 267 322 322
b 56 61 70.5 85.5 91.5 105.5 146 146 175 175
c 35 42 48 59 66 80 94 113 127 140
d 25 29 33 45 51 61 90 90 114 114
e 66 82 98 105 116 136 171 171 200 200
Cat. No. SDLL 520L
SDLL 521L
SDLL 522L
SDLL 523L
SDLL 524L
SDLL 525L
SDLL 526L
SDLL 527L - -
Dimen
sion
a 130 150 176 194 226 281 356 356 - -
b 56 63 74 83.5 100 130 173 173 - -
c 36 51 57 60 70 90 113 122 - -
d 24 32 35 44 52 76 110 110 - -
e 80 96 110 127 157 210 276 276 - -
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
LR Type
Hub
Size
1/2"
16C
3/4"
22C
1"
28C
1-1/4"
36C
1-1/2"
42C
2"
54C
2-1/2"
70C
3"
82C
3-1/2"
92C
4"
104C
Cat. No.SDLR
540M
SDLR
541M
SDLR
542M
SDLR
543M
SDLR
544M
SDLR
545M
SDLR
546M
SDLR
547M
SDLR
548M
SDLR
549M
Dime
nsion
a 115.5 132 155 172 184.5 208.5 267 267 322 322
b 56 61 70.5 85.5 91.5 105.5 146 146 175 175
c 35 42 48 59 66 80 94 113 127 140
d 25 29 33 45 51 61 90 90 114 114
e 66 82 98 105 116 136 171 171 200 200
Cat. No.SDLR
540L
SDLR
541L
SDLR
542L
SDLR
543L
SDLR
544L
SDLR
545L
SDLR
546L
SDLR
547L- -
Dime
nsion
a 130 150 176 194 226 281 356 356 - -
b 56 63 74 83.5 100 130 173 173 - -
c 36 51 57 60 70 90 113 122 - -
d 24 32 35 44 52 76 110 110 - -
e 80 96 110 127 157 210 276 276 - -
T Type
Hub
Size
1/2"
16C
3/4"
22C
1"
28C
1-1/4"
36C
1-1/2"
42C
2"
54C
2-1/2"
70C
3"
82C
3-1/2"
92C
4"
104C
Cat.
No.SDT
550M
SDT
551M
SDT
552M
SDT
553M
SDT
554M
SDT
555M
SDT
556M
SDT
557M
SDT
558M
SDT
559M
Dime
nsion
a 137 152 178 196 210 235 302 302 360 360
b 56 61 70.5 85.5 91.5 105.5 146 146 175 175
c 35 42 48 59 66 80 94 113 127 139.5
d 25 29 33 45 51 61 90 90 114 114
e 66 82 98 105 116 136 171 171 200 200
Cat. No.SDT
550L
SDT
551L
SDT
552L
SDT
553L
SDT
554L
SDT
555L
SDT
556L
SDT
557L- -
Dime
nsion
a 145 165 200 218 250 306 396 396 - -
b 56 65 75 83.5 100 130 170 170 - -
c 44 50 57 65 70 90 113 122 - -
d 25 32 35 44 52 76 110 110 - -
e 80 96 109 127 157 210 276 276 - -
TB Type
Hub
Size
1/2"
16C
3/4"
22C
1"
28C
1-1/4"
36C
1-1/2"
42C
2"
54C
2-1/2"
70C
3"
82C
3-1/2"
92C
4"
104C
Cat. No.
SDTB 560M
SDTB 561M
SDTB 562M
SDTB 563M
SDTB 564M
SDTB 565M
SDTB 566M
SDTB 567M
SDTB 568M
SDTB 569M
Dime
nsion
a 137 152 178 196 210 235 302 302 360 360
b 35 40 45 58 64 75 108 108 133 133
c 55 62 71.5 84.5 93.5 110.5 130 149 167 180
d 25 29 33 45 51 61 90 90 114 114
e 66 82 98 105 116 136 171 171 200 200
Cat. No. SDTB 560L
SDTB 561L
SDTB 562L
SDTB 563L
SDTB 564L
SDTB 565L
SDTB 566L
SDTB 567L
SDTB 568L
SDTB 569L
Dime
nsion
a 166 200 218 249 306 - - - -
b 45 48 58 68 95 - - - -
c 69 82 91.5 100 123 - - - -
d 32 35 44 52 76 - - - -
e 96 110 127 157 210 - - - -
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
X Type
Hub
Size
1/2"
16C
3/4"
22C
1"
28C
1-1/4"
36C
1-1/2"
42C
2"
54C
2-1/2"
70C
3"
82C
3-1/2"
92C
4"
104C
Cat. No.
SDX 570M
SDX 571M
SDX 572M
SDX 573M
SDX 574M
SDX 575M
SDX 576M
SDX 577M
SDX 578M
SDX 579M
Dimen
sion
a 137 152 178 196 210 235 302 302 360 360
b 77 82 96 113 119 136 184 184 217 217
c 35 42 48 59 66 80 94 113 127 139.5
d 25 29 33 45 51 61 90 90 114 114
e 66 82 98 105 116 136 171 171 200 200
Cat. No. SDX 570L
SDX 571L
SDX 572L
SDX 573L
SDX 574L
SDX 575L - - - -
Dimen
sion
a 166 199 218 249 306 - - - -
b 81 98 109 132 165 - - - -
c 51 57 66 70 90 - - - -
d 32 35 44 52 76 - - - -
e 96 110 127 157 210 - - - -
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
Elbow & Union
EUX Union Series
Application
These Union are used ;
to installed in threaded thickwall conduit systems
to connect conduit to a conduit fitting, junction box or
device enclosure
to connect conduit to conduit, or to provide a means
for future modification of the conduit system
Compliance & Certification FeaturesIEC 60079-0, IEC 60079-1
ANSI/UL 886
Certified by UL (Underwriters Laboratories Inc.)
KOSHA (Korea Occupational Safety & Health Agency),
KGS (Korea Gas Safety Corporation), and the others.
compact design which permits assembly with a
minimum of clearance to other adjacent conduit
and/or equipment
strong and durable construction
UL Listed File No. E143517
Standard Materials
Body : Carbon Steel
Options Standard Finish NPT Thread : suffix. NPT
Zinc electro plated
◎ EUX Type of Explosion-proof
Flameproof ( Ex d IIC )
Class I Group C,D Class II Group E,F,G
Type Hub Size Cat. No.Dimen.
A B C
Female
1/2" 16C EUX 310 26 38 38
3/4" 22C EUX 311 31 44 41
1" 28C EUX 312 38 53 47
1-1/4" 36C EUX 313 48 65 53
1-1/2" 42C EUX 314 54 70 59
2" 54C EUX 315 69 80 63
2-1/2" 70C EUX 316 82 99 74
3" 82C EUX 317 95 111 82
3-1/2" 92C EUX 318 123 128 87
4" 104C EUX 319 121 140 105
Male
1/2" 16C EUX 320 35 38 55
3/4" 22C EUX 321 41 44 58
1" 28C EUX 322 50 53 67
1-1/4" 36C EUX 323 61 64 76
1-1/2" 42C EUX 324 67 70 83
2" 54C EUX 325 78 82 88
2-1/2" 70C EUX 326 97 101 105
3" 82C EUX 327 110 114 116
3-1/2" 92C EUX 328 123 128 123
4" 104C EUX 329 134 139 135
SECTION - 3F
Flexible Coupling
SECTION 3F
Flexible Coupling INDEXModel Product Description
Certification for
Explosion-proofPage
WPFC Weatherproof Flexible Coupling 3F - 1
EFCX Flameproof Flexible Coupling Ex d CⅡ 3F - 2
SPFC Increase-Safety Flexible Coupling Ex e Ⅱ 3F - 2
SEJ Expansion Joint 3F - 3
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
Flexible Coupling
WPFC, EFCX, SPFC Series
< WPFC Weatherproof Type >
< EFCX Flameproof Type >
< SPFC Increase Safety Type >
Application Features
Cover openings on an angle, permitting conductors
to be pulled straight through either hub.
Taper tapped hubs and integral bushing for rigid
threaded conduit.
Maximum volume for bends within a compact
overall size.
Domed covers to permit easy conductor bends.
Screw on cover for ease of installation and
removal.
These Flexible Couplings are ;
where ignitable concentrations of flammable gases,
vapors or liquids can exist some of the time under
normal operation conditions.
Certification
Certified by KOSHA (Korea Occupational Safety &
Health Agency), KGS (Korea Gas Safety Corporation),
and the others.
Standard Finish Option
Zinc Electro Plated Chromate Finish
If you want another color, contact us please.
NPT Thread : suffix. NPT
Length : Contact us, please
(Standard is 500mm, 1000mm)
WPFC Weatherproof Type
Hub Size Cat No.Dimension Weight
( )㎏L A B
1/2" 16C WPFC 570 500
37 340.9
WPFC 580 1000 1.2
3/4" 22CWPFC 571 500
44 411.1
WPFC 581 1000 1.5
1" 28CWPFC 572 500
53 491.3
WPFC 582 1000 1.8
1-1/4" 36CWPFC 573 500
64 591.9
WPFC 583 1000 2.6
1-1/2" 42CWPFC 574 500
72 673.2
WPFC 584 1000 3.8
2" 54CWPFC 575 500
90 852.9
WPFC 585 1000 3.9
Standard Materials 2-1/2" 70CWPFC 576 500
107 993.8
WPFC 586 1000 4.9Flexible Tube : Plica Tube with PVC
covering
End Fitting : Brass
Finish : Zinc Electro Plated Chromate
Finish
3" 82CWPFC 577 500
116 1115.2
WPFC 587 1000 6.7
3-1/2" 92CWPFC 578 500 6.6
WPFC 588 1000 8.1
4" 104CWPFC 579 500
152 1468.0
WPFC 589 1000 9.5
* Length is order made, contact us please.
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
EFCX Type of Explosion-proof
Flameproof ( Ex d IIC )
Hub Size Cat No.Dimension Weight
( )㎏L A B
1/2" 16C EFCX 1500 500
38 350.8
EFCX 1520 1000 1.0
3/4" 22CEFCX 1501 500
47 421.0
EFCX 1521 1000 1.3
1" 28CEFCX 1502 500
53 491.4
EFCX 1522 1000 1.8
1-1/4" 36CEFCX 1503 500
64 602.1
EFCX 1523 1000 2.6
1-1/2" 42CEFCX 1504 500
78 742.4
EFCX 1524 1000 3.2
2" 54CEFCX 1505 500
97 913.2
EFCX 1525 1000 5.3
Standard Materials 2-1/2" 70CEFCX 1506 500
113 1076.3
EFCX 1526 1000 7.4
Flexible Tube : Stainless Steel
End Fitting : Brass
Finish : Zinc Electro Plated Chromate
Finish
3" 82CEFCX 1507 500
122 1168.1
EFCX 1527 1000 12.2
3-1/2" 92CEFCX 1508 500 10.0
EFCX 1528 1000 15.2
4" 104CEFCX 1509 500
141 13512.2
EFCX 1529 1000 18.2
* Length is order made, contact us please.
SPFC Type of Explosion-proof
Increase Safety ( Ex e II )
Hub Size Cat No.Dimension Weight
( )㎏L A B
1/2" 16C SPFC 570 500
37 340.9
SPFC 580 1000 1.2
3/4" 22CSPFC 571 500
44 411.1
SPFC 581 1000 1.5
1" 28CSPFC 572 500
53 491.3
SPFC 582 1000 1.8
1-1/4" 36CSPFC 573 500
64 591.9
SPFC 583 1000 2.6
1-1/2" 42CSPFC 574 500
72 673.2
SPFC 584 1000 3.8
2" 54CSPFC 575 500
90 852.9
SPFC 585 1000 3.9
Standard Materials 2-1/2" 70CSPFC 576 500
107 993.8
SPFC 586 1000 4.9
Flexible Tube : Plica Tube with PVC
covering
End Fitting : Brass
Finish : Zinc Electro Plated Chromate
Finish
3" 82CSPFC 577 500
116 1115.2
SPFC 587 1000 6.7
3-1/2" 92CSPFC 578 500 6.6
SPFC 588 1000 8.1
4" 104CSPFC 579 500
152 1468.0
SPFC 589 1000 9.5
* Length is order made, contact us please.
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
Expansion Joint
SEJ Series
Application
These SEJ Expansion Joints are used ;
in long conduit runs, to permit linear movement
caused by thermal expansion and contraction
in long conduit runs to prevent conduit from buckling
and circuit failures
FeaturesWeathertight construction
Insulator bushing on end of movable conduit.
Factory-formed fiberglass/ copper wire ring, lubricated
and graphited throughout for easy sliding of the
conduit in expansion and contraction.
Standard Materials
Body : Steel Conduit
Standard Finish
Zinc electro plated
◎ SEJ
Hub Size Cat. No.Max. Conduit
Movement
Min. Length
of Strap
Dimen.
A B C
1/2"
16C
SEJ 110 100 720 54 57 165
SEJ 210 200 920 54 57 265
3/4"
22C
SEJ 111 100 770 54 57 170
SEJ 211 200 970 54 57 270
1"
28C
SEJ 112 100 820 60 64 175
SEJ 212 200 1020 60 64 275
1-1/4"
36C
SEJ 113 100 870 62 78 180
SEJ 213 200 1070 62 78 280
1-1/2"
42C
SEJ 114 100 920 71 94 190
SEJ 214 200 1120 71 94 290
2"
54C
SEJ 115 100 1020 78 114 200
SEJ 215 200 1220 78 114 300
2-1/2"
70C
SEJ 116 100 1120 94 134 210
SEJ 216 200 1320 94 134 310
3"
82C
SEJ 117 100 1220 106 162 220
SEJ 217 200 1420 106 162 320
3-1/2"
92C
SEJ 118 100 1530 106 174 230
SEJ 218 200 1730 106 174 330
4"
104C
SEJ 119 100 1680 108 186 230
SEJ 219 200 1880 108 186 330
SECTION - 4F
Sealing Fitting & Drain
SECTION 4F
Sealing Fitting & Drain INDEX
Model Product DescriptionCertification for Explosion-proof
Page
IEC UL
EFZ Any Angle Type Sealing Fitting Ex d CⅡ 4F - 2
EFV Vertical Type Sealing Fitting Ex d CⅡ
Class I
Group C,D
Class II
Group E,F,G
4F - 2
EFVH Vertical or Horizontal Type Sealing Fitting Ex d CⅡ
Class I
Group C,D
Class II
Group E,F,G
4F - 2
EFVD Drain Sealing Fitting Ex d CⅡ 4F - 3
EDF Drain Sealing Fitting Ex d CⅡ 4F - 3
EFU Replace Type Sealing Fitting & Drain Ex d BⅡ 4F - 4
ECD 15 Universal Drain or Breather Ex d CⅡ 4F - 5
ECD 16 Breather Ex d CⅡ 4F - 5
ECD 17 Drain Ex d CⅡ 4F - 5
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
Sealing Fitting & Drain
EFZ, EFV, EFVH, EFVD
Attention for Marking Seal Features
Do not splice any conductors in the sealing
fittings regardless the characteristics of the
sealing compound.
Make the sealing dam with the care using
the asbestos packing supplied with the
sealing compound. If the poured compound
leaks into the conduit, the quality of seal
would become insufficient, and it would be
a cause of trouble.
The sealing compound should be mixed with
water a little harder. Over addition of
solution or water may weaken the seal.
The sealing compound shall be poured so
as not to leave large bubbles in the seal.
The bubbles are come out by insufficient
fluidity and wrong pouring manner. For
removing bubbles, it is effective to pat the
sealing fitting gently just after the filling.
It is rather difficult to achieve good seal in
horizontal conduit run than in the vertical.
Therefore, when the any angle type sealing
fitting is used in horizontal conduit run, set
the cover with the filling opening at as high
position as possible, and pour the sealing
compound full.
EFV, EFVH Series Sealing Fittings are
minimum turning radius.
large openings with threaded closures to
provide easy access to conduit hubs for
making dams.
integral bushings in conduit hubs to
protect conductor insulation from damage.
taper-tapped hubs to insure ground
continuity.
EFZ Any Angle Type Sealing Fittings are
can be used for sealing horizontal, vertical
and other sloped conduit runs.
have large cover openings which provide
easy access to both hubs for making
sealing dam and pouring sealing
compound.
EFVD Series Drain Sealing Fittings are
drain to Provide continuous, automatic
drainage of condensate.
removable male nipple supplied when male
and female style is ordered.
Application
Sealing Fittings are used in;
restrict the passage of gases, vapors or
flames from one portion of the electrical
installation to another at atmospheric
pressure and normal ambient temperatures.
limit explosions to the sealed off enclosure.
prevent precompression or "pressure
piling" on conduit systems.
drain sealing fittings are installed in
vertical conduit runs and at low points in
conduit systems to prevent accumulation
of condensate above seal.
Compliance & CertificationIEC 60079-0, 1
ANSI/UL 886
UL Listed File No. E 143517 (EFV, EFVH
Series)
Certified by UL (Underwriters Laboratories
Inc.), KOSHA (Korea Occupational Safety
& Health Agency), KGS (Korea Gas Safety
Corporation), and the others.
Standard Finish
Hot Dip. Galvanized with stove enamelled
silver white
If you want another color, contact us
please.
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
◎ EFZ Sealing Fitting Type of Explosion-proof Flameproof ( Ex d IIC )
Hub Size Cat. No.Dimen. ( )㎜
A B C D
1/2" 16C EFZ 300 100 42 48 83
3/4" 22C EFZ 301 105 42 48 88
1" 28C EFZ 302 110 42 48 98
1-1/4" 36C EFZ 303 125 58 67 113
1-1/2" 42C EFZ 304 130 58 67 119
2" 54C EFZ 305 180 58 67 131
2-1/2" 70C EFZ 306 200 77 84 156
3" 82C EFZ 307 215 77 84 170
3-1/2" 92C EFZ 308 235 90 110 185
4" 104C EFZ 309 245 90 110 210
Standard Materials Installation TypeCast Iron Any Angle Type
◎ EFV Sealing Fitting Type of Explosion-proof
Flameproof ( Ex d IIC )
Class I Group C,D Class II Group E,F,G
Flameproof EFV Sealing Fittings, Vertical type
Hub SizeCat. No. Dimen. ( )㎜
Female Male & Female A B C
1/2" 16C EFV 100 EFV 100M 108 32 70
3/4" 22C EFV 101 EFV 101M 114 36 73
1" 28C EFV 102 EFV 102M 128 43 84
1-1/4" 36C EFV 103 EFV 103M 150 53 104
1-1/2" 42C EFV 104 EFV 104M 170 60 116
2" 54C EFV 105 EFV 105M 200 74 141
2-1/2" 70C EFV 106 EFV 106M 220 90 167
3" 82C EFV 107 EFV 107M 250 106 201
3-1/2" 92C EFV 108 EFV 108M - - -
4" 104C EFV 109 EFV 109M 286 132 237
Flameproof EFVH Sealing Fittings, Horizontal type
Hub SizeCat. No. Dimen. ( )㎜
Female Male & Female A B C
1/2" 16C EFVH 100 EFVH 100M 90 32 46
3/4" 22C EFVH 101 EFVH 101M 110 36 60
1" 28C EFVH 102 EFVH 102M 120 43 70
1-1/4" 36C EFVH 103 EFVH 103M 130 53 80
1-1/2" 42C EFVH 104 EFVH 104M 144 60 88
2" 54C EFVH 105 EFVH 105M 165 74 103
2-1/2" 70C EFVH 106 EFVH 106M 200 90 116
3" 82C EFVH 107 EFVH 107M 215 106 138
3-1/2" 92C EFVH 108 EFVH 108M - - -
4" 104C EFVH 109 EFVH 109M 245 132 160
Standard Materials FinishesCast Iron Hot Dip Galvanize with stove enamelled silver
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
◎ EFVD Drain Sealing Fitting Type of Explosion-proof
Flameproof ( Ex d IIC )
Hub SizeCat. No. Dimen. ( )㎜
Female Male & Female A B C D
1/2" 16C EFVD 816 EFVD 816M 83 32 62 57
3/4" 22C EFVD 822 EFVD 822M 94 36 66 66
1" 28C EFVD 828 EFVD 828M 110 43 75 78
1-1/4" 36C EFVD 836 EFVD 836M 130 53 80 101
1-1/2" 42C EFVD 842 EFVD 842M 144 60 88 105
2" 54C EFVD 854 EFVD 854M 165 74 103 125
2-1/2" 70C EFVD 870 EFVD 870M 200 90 116 139
3" 82C EFVD 882 EFVD 882M 215 106 138 163
3-1/2" 92C EFVD 892 EFVD 892M - - - -
4" 104C EFVD 8104 EFVD 8104M 245 132 160 189
Standard MaterialsBody : Cast Iron
Drain : Stainless steel
Removable Nipple : Steel
◎ EDF Drain Sealing Fitting Type of Explosion-proof
Flameproof ( Ex d IIC )
Hub Size Cat. No.Dimen. ( )㎜
A B C D
1/2" 16C EDF 900 115 85 85 70
3/4" 22C EDF 901 115 90 85 70
1" 28C EDF 902 135 105 90 80
1-1/4" 36C EDF 903 135 115 90 80
1-1/2" 42C EDF 904 150 120 100 95
2" 54C EDF 905 170 130 100 95
2-1/2" 70C EDF 906 200 140 100 95
3" 82C EDF 907 215 153 100 95
3-1/2" 92C EDF 908 235 168 100 95
4" 104C EDF 909 245 181 100 95
Standard MaterialsBody : Cast Iron
Drain : Stainless steel
Removable Nipple : Steel
Sealing Compound Required (g)
Hub Size 1/2" 16C 3/4" 22C 1" 28C 1-1/4" 36C 1-1/2" 42C 2" 54C 2-1/2" 70C 3" 82C 3-1/2" 92C 4" 104C
EDF 120 140 210 260 300 430 500 600 800 1,000
EFZ 90 110 130 220 270 440 800 1,050 1,600 2,000
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
Retrofit Sealing Fitting & Drain
EFU Series
Type of Explosion-proof
Flameproof (Ex d IIB)
Application
EFU Series retrofit sealing fittings are installed;
in rigid metal conduit systems in hazardous locations.
to replace installed EFV type sealing fittings.
without disassembly of the conduit system.
in vertical or horizontal positions, indoors or outdoors.
to restrict the passage of gases, vapors or flames from
one portion of the electrical system to another at
atmospheric pressures and normal ambient
temperatures.
to limit explosions to the sealed-off enclosure.
to limit precompression or "pressure piling" in the
conduit system.
Features Standard Materials
Seal may be installed in the existing conduit run without disassembly of the conduit system saving time and labor.Overall length and spacing requirements do not exceed those of standard EFV seals; permits close nesting of seals.Pipe plugs permit the installation of a standard EFVD drain fitting for use in vertical conduit runs to drain any water that might accumulate in the conduits system.Steel set screws provide grounding continuity.Suitable for vertical and horizontal installations for indoor and outdoor applications.Available in 3/4" to 4" NPT size.
Enclosure : Cast Iron
Pipe plugs, bolts and set screws : Steel
Gasket : Neoprene
Compliance & Certification
IEC 60079-0, 1Certified by UL (Underwriters Laboratories Inc.)
Certified by KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others.
Standard Finish
Cast Iron :
Electrogalvanized and Aluminium acrylic paint
Steel : Electrogalvanized
Gasket : Natural
If you want another color, contact us please.
Entry Size
3/4"(22C) ~ 4“(104C)
Ordering Number
Hub
Size
Cat
No
Internal Volume
(cm3)
Amount of Fiber
per Hub (g)Dimension (mm)
Vert. Horz. Vert. Horz. A B C
3/4" EFU1 57.2 94 1.8 3.5 93 64 38
1" EFU2 77.6 155 3.5 7 111 79 79
1-1/4" EFU3 114 220 7 14 127 85 76
1-1/2" EFU4 200 396 14 28.3 133 92 76
2" EFU5 420 661 28.3 56.6 158 101 76
2-1/2" EFU6 784 1,233 42.5 85 190 127 98
3" EFU7 1,413 2,059 56.6 113 216 139 108
3-1/2" EFU8 2,402 3,431 127 254 233 154 120
4" EFU9 3,039 4,117 127 254 247 168 133
If you need more information, contact us please. ⇨
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
Drain & Breather
ECD Series
Type of Explosion-proof Flameproof (Ex d IIC)
Male
Threaded
Size
Drain and Breather
"Universal"
Drain or
Breather
Breather for
Air only
Drain for
Water only
Catalog Number16 ½" ECD 15 ECD 16 ECD 17
Application Features ECD drains and breathers are installed in enclosures or
conduit systems to ;
provide ventilation to minimize.
condensation.
drain accumulated condensate.
at least one breather should be used with such
drain.
A "standard" drain is installed in bottom of enclosure
or in lower section of conduit system.
Universal "breather or drain functions as breathe
when mounted at the top of an enclosure, or as a
drain when mounted in be bottom of an enclosure".
drains and breathers are installed in hubs drilled and
tapped openings.
"Universal" ECD drains and breathers have :
Patented labyrinth design, suitable for use in Class , Ⅰ
Division 1 & 2, Groups C,D and Class , Division 1 & Ⅱ
2, Groups F,G areas.
Capability to pass 50 cc of water per minute and 0.2
cubic feet or air per minute at atmospheric pressure.
ECD15 have a well inside the inner, threaded end to
provide for accumulation of sediment without clogging
when used as a drain.
"Standard" ECD drains and breathers have:
thread-in-thread design, suitable for use in Class , Ⅰ
Division 1 & 2, Groups C,D and Class , Division 1, Ⅱ
Groups E,F,G; Class , Division 2, Groups F,G and Ⅱ
Class areas.Ⅲ
ECD 16, 17 are thread0in-thread design for use in
Class , Division 1 & 2, Groups B,C,D; Class , Ⅰ Ⅱ
Division 1, Groups E,F,G; Class , Division 2, Groups Ⅱ
F,G and Class areas.Ⅲ
They have the capability to pass 0.1 cubic feet of air
per minute and 0.5cc of water per minute.
Standard Materials Standard Finish
ECD 15 : Stainless steel
ECD 16, 17 : Brass (Stainless steel is order made.)
Natural
If you want another color, contact us please.
If you need more information, contact us please. ⇨
SECTION - 5F
Cable Gland
SECTION 5F
Cable Gland INDEX
Model
Gland Type
Certification for
Explosion-proofPage
Cable Type Seal For
SWA STALead
CoveredSWA
UnArmoured
Not Seal
Outer only
Outer +
Inner
Indoor
Outdoor
Zone 1 & 2
E1FW ● ● ● ● ●Ex d CⅡ
Ex e Ⅱ5F - 2
E1W ● ● ● ● 5F - 2
E2FW ● ● ● ● ●Ex d CⅡ
Ex e Ⅱ5F - 3
E2W ● ● ● ● 5F - 3
CW ● ● 5F - 4
BW ● ● 5F - 4
A2F ● ● ● ● ●Ex d CⅡ
Ex e Ⅱ5F - 5
A2 ● ● ● ● 5F - 5
A4e ● ● ● ● ● Ex e Ⅱ 5F - 6
A4 ● ● ● ● 5F - 6
Acces
soryCable Gland Accessories 5F - 7
EG Conduit Fittings Packing Cable Gland
Ex d IIC
5F - 8
EGC Conduit Fittings Packing Cable Gland 5F - 9
EPG Conduit Fittings Packing Cable Gland 5F - 9
EUG Conduit Fittings Packing Cable Gland 5F - 9
NAMBUK Cable Gland
Copyright by NAMBUK Electric Co., LTD. 2008
Armoured / Un-armoured Cable Gland
Application
These cable glands are used ;
suited to armoured/un-armoured cables used mainly in
areas where British Standards apply.
particularly suited to Steel Wire Armoured Cable.
compliance to BS 6121:1989.
available in standard industrial or explosion protected
designs for "Ex" equipment in both "flameproof" and
"increased" enclosures (E1FW, E2FW, A2F).
compliance to IEC 60079-0, 60079-1 and 60079-7,
60079-14, EN 50014, 50018 and 50019 (E1FW, E2FW,
A2F).
can be used in Zone 1 and Zone 2 (E1FW, E2FW, A2F)
degree of protection max. IP66.
available in metric and NPT inlet threads.
Operating Temperature : -20 ~ +80℃ ℃
Features Standard Materials
2 or 3 part armour / earth lock.
Knurled armour lock produces a low resistance earth
clamp.
Inner and outer displacement seal.
Gland entry rated at IP66 with NAMBUK entry thread
seal.
Easy and fast to install.
Displacement seal concept ensures effective seal to
inner and outer sheath.
Displacement seals suited to most hostile environments.
Body : Brass, Aluminium
Lock Nut : Brass, Aluminium
Earth Tag : Brass
Metric Entry Thread Seal : Nylon
Shroud : PVC / LSF
Options
Combination concept
Alternative materials / plating
Cast integral earth lug
Entry thread : NPT, PF, NPS, PG and the others
EeCFC Seal for cable exhibit "cold flow" characteristicsStandard Finish
Natural / Nickel Plated
If you want another finish, contact us please.
Degree of Protection
Gland TypeEntry thread PVC shroud and entry thread
with seal without seal with seal without seal
E1FW, E1W, E2FW, E2W, A2F, A2, A4e, A4, CW IP 66 IP 54 IP 66 IP 54
Gland Selection Entry Thread
Gland Type E1FW E1W E2FW E2W BW CW A2 A2F A4 A4e Size Metric NPT PG PF
Cable
Type
SWA ◆ ◆ ◆ ◆ ◆ 20/16 20 1/2" 11 1/2"
STA ◆ ◆ 20S 20 1/2" 13.5 1/2"
SWA Lead Sheathed ◆ ◆ 20 20 1/2", 3/4" 16 1/2", 3/4"
Un-armoured ◆ ◆ 25 25 3/4", 1" 21 3/4", 1"
Seal
Not Seal ◆ 32 32 1", 1-1/4" 29 1", 1-1/4"
Outer only ◆ ◆ ◆ ◆ ◆ 40 40 1-1/4", 1-1/2" 36 1-1/4", 1-1/2"
Outer + Inner ◆ ◆ ◆ ◆ 50S 50 1-1/2" 36 1-1/2"
For
Indoor ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ 50 50 2" 42 2"
Outdoor ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ 63S 63 2“ 48 2“
Zone 1 & 2 ◆ ◆ ◆ ◆ 63 63 2-1/2" - 2-1/2"
75S 75 2-1/2" - 2-1/2"1) Check conditions of use (i.e. industrial, Ex d, etc)
75 75 3“ - 2-1/2" or 3“2) Check cable external diameter90 90 3-1/2“ - 3" or 3-1/2“3) Check cable under-armour diameter
4) Check type of armour and thickness
5) Check accessories (i.e. shrouds, earth tags etc) If you need more data, contact us please. ⇨
NAMBUK Cable Gland
Copyright by NAMBUK Electric Co., LTD. 2008
Armoured Cable Gland
for SWA Cable,
Explosion-proof Type
Type of Explosion-proof Flameproof ( Ex d IIC )
Increase Safety ( Ex e II )
Certificate No : PTB No. Ex - 05 IEC 1005X
Technical Data
Type E1FW Cable Type Steel Wire Armour
GlandMaterial Brass Sealing
Area Inner & Outer Sheath
SealMaterial
Thermoplastic Elastomer For Area
Indoor Outdoor
Hazardous Area
Ordering Number & Dimension Accessory
Cable
Gland
Size
Entry Thread 'C' Thread
Length
'D'
Cable Dimensions Armour
Wire Dia
(SWA)
Max
Dia
'E'
Shrouds, Earth Tags,
Locknuts, Metric Entry Thread
Seals - see accessory page.Metric NPT PF
Cable Dia 'A'
Min Max
Cable Dia 'B'
Min Max
20/16 20 1/2" 1/2" 18 3.0 - 8.6 14.0 - 14.0 0.9 25
20S 20 1/2" 1/2" 18 6.0 - 11.6 14.0 - 15.9 0.9/1.25 31
Option20 20 1/2" 1/2" 18 8.0 - 13.9 14.0 - 20.9 0.9/1.25 34
25 25 3/4" 3/4" 20 13.0 - 19.9 18.1 - 26.2 1.25/1.6 44 Can choice EeCFC Seal
instead of standard seal
when use with certain cable
type that exhibit "cold flow"
characteristics
32 32 1" 1" 23 17.0 - 26.2 24.3 - 33.9 1.6/2 53
40 40 1-1/4" 1-1/4" 23 24.0 - 32.1 28.0 - 40.4 1.6/2 61
50S 50 1-1/2" 1-1/2" 23 30.0 - 38.1 38.0 - 46.7 2/2.5 67
50 50 2" 2" 25 36.0 - 44.0 43.0 - 53.1 2/2.5 78
63S 63 2“ 2“ 25 42.0 - 49.9 48.6 - 59.4 2.5 80
63 63 2-1/2" 2-1/2" 30 48.0 - 55.9 56.2 - 65.9 2.5 88
75S 75 2-1/2" 2-1/2" 30 52.8 - 61.9 60.2 - 72.1 2.5 104
75 75 3“ 2-1/2" 30 55.0 - 64.0 61.0 - 78.5 2.5/3.15 110
90 90 3“ 3" 30 68.0 - 79.3 81.4 - 90.4 3.15 127
Armoured Cable Gland
for SWA Cable, General or Regular Type
Technical Data
Type E1W Cable Type Steel Wire Armour
Gland
MaterialBrass
Sealing
AreaInner & Outer Sheath
Seal
MaterialThermoplastic
Elastomer For AreaIndoor
Outdoor
Ordering Number & Dimension Accessory
Cable
Gland
Size
Entry Thread 'C' Thread
Length
'D'
Cable Dimensions Armour
Wire Dia
(SWA)
Max
Dia
'E'
Shrouds, Earth Tags,
Locknuts, Metric Entry
Thread Seals - see
accessory page.
Metric NPT PFCable Dia 'A'
Min Max
Cable Dia 'B'
Min Max20/16 20 1/2" 1/2" 18 3.0 - 8.6 14.0 - 14.0 0.9 25
20S 20 1/2" 1/2" 18 6.0 - 11.6 14.0 - 15.9 0.9/1.25 31
20 20 1/2" 1/2" 18 8.0 - 13.9 14.0 - 20.9 0.9/1.25 34
25 25 3/4" 3/4" 20 13.0 - 19.9 18.1 - 26.2 1.25/1.6 44
Option32 32 1" 1" 23 17.0 - 26.2 24.3 - 33.9 1.6/2 53
40 40 1-1/4" 1-1/4" 23 24.0 - 32.1 28.0 - 40.4 1.6/2 61 Can choice EeCFC Seal
instead of standard seal
when use with certain
cable type that exhibit
"cold flow" characteristics
50S 50 1-1/2" 1-1/2" 23 30.0 - 38.1 38.0 - 46.7 2/2.5 67
50 50 2" 2" 25 36.0 - 44.0 43.0 - 53.1 2/2.5 78
63S 63 2“ 2“ 25 42.0 - 49.9 48.6 - 59.4 2.5 80
63 63 2-1/2" 2-1/2" 30 48.0 - 55.9 56.2 - 65.9 2.5 88
75S 75 2-1/2" 2-1/2" 30 52.8 - 61.9 60.2 - 72.1 2.5 104
75 75 3“ 2-1/2" 30 55.0 - 64.0 61.0 - 78.5 2.5/3.15 110
90 90 3“ 3“ 30 68.0 - 79.3 81.4 - 90.4 3.15 127
NAMBUK Cable Gland
Copyright by NAMBUK Electric Co., LTD. 2008
Armoured Cable Gland
for SWA Cable,
Explosion-proof Type
Type of Explosion-proof Flameproof (Ex d IIC)
Increase Safety (Ex e II)
Certificate No : PTB No. Ex - 07 IEC 1007X
Technical Data
Type E2FW Cable Type Lead Covered
Steel Wire Armour
Gland
MaterialBrass
Sealing
AreaInner & Outer Sheath
Seal
MaterialThermoplastic
Elastomer For Area
Indoor
Outdoor
Hazardous Area
Ordering Number & Dimension Accessory
Cable
Gland
Size
Entry Thread 'C' Thread
Length
'D'
Cable Dimensions Armour
Wire Dia
(SWA)
Max Dia
'E'
Shrouds, Earth Tags,
Locknuts, Metric Entry
Thread Seals - see
accessory page.
Metric NPT PFCable Dia 'A'
Min Max
Cable Dia 'B'
Min Max20S 20 1/2" 1/2" 18 6.6 - 11.6 14.0 - 15.9 0.9/1.25 31
20 20 1/2" 1/2" 18 8.0 - 13.9 14.0 - 20.9 0.9/1.25 34
25 25 3/4" 3/4" 20 13.0 - 19.9 22.8 - 26.2 1.25/1.6 44
32 32 1" 1" 23 17.0 - 26.2 24.0 - 33.9 1.6/2 53
40 40 1-1/4" 1-1/4" 23 24.0 - 32.1 30.0 - 40.4 1.6/2 61
50S 50 1-1/2" 1-1/2" 23 30.0 - 38.1 37.5 - 46.7 2/2.5 67
50 50 2" 2" 25 36.0 - 44.0 43.5 - 53.1 2/2.5 78
63S 63 2“ 2“ 25 42.0 - 49.9 49.5 - 59.4 2.5 80
63 63 2-1/2" 2-1/2" 30 48.0 - 55.9 56.5 - 65.9 2.5 88
75S 75 2-1/2" 2-1/2" 30 52.8 - 61.9 56.5 - 72.1 2.5 104
75 75 3“ 2-1/2" 30 57.0 - 64.0 61.0 - 78.5 2.5/3.15 110
90 90 3“ 3“ 30 69.0 - 79.3 78.0 - 90.4 3.15 127
Armoured Cable Gland
for SWA Cable, General or Regular Type
Technical Data
Type E2W Cable Type Steel Wire Armour
Gland
MaterialBrass
Sealing
AreaInner & Outer Sheath
Seal
MaterialThermoplastic
Elastomer For AreaIndoor
Outdoor
Ordering Number & Dimension Accessory
Cable
Gland
Size
Entry Thread 'C' Thread
Length
'D'
Cable Dimensions Armour
Wire Dia
(SWA)
Max Dia
'E'Shrouds, Earth Tags,
Locknuts, Metric Entry
Thread Seals - see
accessory page.
Metric NPT PFCable Dia 'A'
Min Max
Cable Dia 'B'
Min Max20S 20 1/2" 1/2" 18 6.6 - 11.6 14.0 - 15.9 0.9/1.25 31
20 20 1/2" 1/2" 18 8.0 - 13.9 14.0 - 20.9 0.9/1.25 34
25 25 3/4" 3/4" 20 13.0 - 19.9 22.8 - 26.2 1.25/1.6 44
32 32 1" 1" 23 17.0 - 26.2 24.0 - 33.9 1.6/2 53
40 40 1-1/4" 1-1/4" 23 24.0 - 32.1 30.0 - 40.4 1.6/2 61
50S 50 1-1/2" 1-1/2" 23 30.0 - 38.1 37.5 - 46.7 2/2.5 67
50 50 2" 2" 25 36.0 - 44.0 43.5 - 53.1 2/2.5 78
63S 63 2“ 2“ 25 42.0 - 49.9 49.5 - 59.4 2.5 80
63 63 2-1/2" 2-1/2" 30 48.0 - 55.9 56.5 - 65.9 2.5 88
75S 75 2-1/2" 2-1/2" 30 52.8 - 61.9 56.5 - 72.1 2.5 104
75 75 3“ 2-1/2" 30 57.0 - 64.0 61.0 - 78.5 2.5/3.15 110
90 90 3“ 3“ 30 69.0 - 79.3 78.0 - 90.4 3.15 127
NAMBUK Cable Gland
Copyright by NAMBUK Electric Co., LTD. 2008
Armoured Cable Gland
for SWA Cable, General or Regular Type
Technical Data
Type CW Cable Type Steel Wire Armour
Gland
Material Brass
Sealing
AreaInner & Outer Sheath
Seal
MaterialThermoplastic
Elastomer For AreaIndoor
Outdoor
Ordering Number & Dimension Accessory
Cable
Gland
Size
Entry Thread 'C' Thread
Length
'D'
Cable Dimensions Armour
Wire Dia
(SWA)
Max Dia
'E'
Shrouds, Earth Tags,
Locknuts, Entry
Thread Seals - see
accessory page.
Metric NPT PFCable Dia 'A'
Max
Cable Dia 'B'
Min Max
20/16 20 1/2" 1/2" 15 8.6 6.0 - 13.4 0.9 24.4
20S 20 1/2" 1/2" 10 11.6 9.5 - 15.9 0.9/1.25 26.6
20 20 1/2" 1/2" 10 13.9 12.5 - 20.9 0.9/1.25 33.3
25 25 3/4" 3/4" 10 19.9 17.0 - 26.2 1.25/1.6 40.5
32 32 1" 1" 10 26.2 22.9 - 33.9 1.6/2 51.0
40 40 1-1/4" 1-1/4" 15 32.1 26.0 - 40.4 1.6/2 61.0
50S 50 1-1/2" 1-1/2" 15 38.1 35.0 - 46.7 2/2.5 66.5
50 50 2" 2" 15 44.0 38.0 - 53.1 2/2.5 77.7
63S 63 2“ 2“ 15 50.0 45.6 - 59.4 2.5 83.2
63 63 2-1/2" 2-1/2" 15 55.9 54.6 - 65.9 2.5 88.7
75S 75 2-1/2" 2-1/2" 15 61.9 57.0 - 72.1 2.5 101.6
75 75 3“ 2-1/2" 15 67.9 60.4 - 78.5 2.5/3.15 111.1
90 90 3“ 3“ 15 79.3 69.2 - 90.4 3.15 128.6
Armoured Cable Gland
for SWA Cable, General or Regular Type
Technical Data
Type BW Cable Type Steel Wire Armour
Gland Material Brass For Area Indoor
Ordering Number & Dimension Accessory
Cable
Gland
Size
Metric
Entry Thread 'C'
Thread
Length
'D'
Cable Dimensions Armour
Wire Dia
(SWA)
Max Dia
'E'
Shrouds, Earth Tags,
Locknuts, Serrated
Washer - see
accessory page.
Cable Dia 'A'
Max
Cable Dia 'B'
Max
20S 20 10 11.6 16.1 0.9/1.25 24.0
20 20 10 13.9 21.1 0.9/1.25 30.0
25 25 10 19.9 27.4 1.25/1.6 36.0
32 32 10 26.2 34.4 1.6/2 44.5
40 40 15 32.1 42.4 1.6/2 56.3
50S 50 15 38.1 50.1 2/2.5 63.4
50 50 15 44.0 55.7 2/2.5 72.1
63S 63 15 50.0 62.4 2.5 83.0
63 63 15 55.9 68.2 2.5 88.7
75S 75 15 61.9 76.8 2.5 99.8
75 75 15 67.9 82.9 2.5/3.15 105.3
NAMBUK Cable Gland
Copyright by NAMBUK Electric Co., LTD. 2008
Unarmoured Cable Gland
Explosion-proof Type
Type of Explosion-proof Flameproof (Ex d IIC)
Increase Safety (Ex e II)
Certificate No : PTB No. Ex - 07 IEC 1067X
Technical Data
Type A2F Cable Type Unarmoured
Gland
MaterialBrass
Sealing
AreaOuter Sheath
Seal
MaterialThermoplastic
Elastomer For Area
Indoor
Outdoor
Hazardous Area
Ordering Number & Dimension Accessory
Cable
Gland
Size
Entry Thread 'B'Thread
Length 'C'
Cable Dia 'A'
Min Max
Max Dia
'D'Shrouds, Earth Tags,
Locknuts, Entry
Thread Seals - see
accessory page.
Metric NPT PF
20/16 20 1/2" 1/2" 17 3.0 - 8.0 26
20S 20 1/2" 1/2" 17 6.0 - 11.5 32.5
20 20 1/2" 1/2" 17 11.0 - 13.5 32.5
25 25 3/4" 3/4" 20 13.2 - 19.5 41
32 32 1" 1" 23 17.0 - 25.5 55
40 40 1-1/4" 1-1/4" 23 22.3 - 32.0 60
50S 50 1-1/2" 1-1/2" 24 31.6 - 37.0 70
50 50 2" 2" 26 35.7 - 43.0 86
63S 63 2“ 2“ 26 40.3 - 50.0 86
63 63 2-1/2" 2-1/2" 30 47.3 - 55.0 97
75S 75 2-1/2" 2-1/2" 30 53.0 - 61.0 97
75 75 3“ 2-1/2" 30 60.5 - 67.0 109
90 90 3“ 3“ 30 66.7 - 79.0 120
Unarmoured Cable Gland
General or Regular Type
Technical Data
Type A2 Cable Type Unarmoured
Gland
MaterialBrass
Sealing
AreaOuter Sheath
Seal
MaterialThermoplastic
Elastomer For AreaIndoor
Outdoor
Ordering Number & Dimension Accessory
Cable
Gland
Size
Entry Thread 'B'Thread
Length 'C'
Cable Dia 'A'
Min Max
Max Dia
'D'Shrouds, Earth Tags,
Locknuts, Entry
Thread Seals - see
accessory page.
Metric NPT PF
20/16 20 1/2" 1/2" 17 3.0 - 8.0 26
20S 20 1/2" 1/2" 17 6.0 - 11.5 32.5
20 20 1/2" 1/2" 17 11.0 - 13.5 32.5
25 25 3/4" 3/4" 20 13.2 - 19.5 41
32 32 1" 1" 23 17.0 - 25.5 55
40 40 1-1/4" 1-1/4" 23 22.3 - 32.0 60
50S 50 1-1/2" 1-1/2" 24 31.6 - 37.0 70
50 50 2" 2" 26 35.7 - 43.0 86
63S 63 2“ 2“ 26 40.3 - 50.0 86
63 63 2-1/2" 2-1/2" 30 47.3 - 55.0 97
75S 75 2-1/2" 2-1/2" 30 53.0 - 61.0 97
75 75 3“ 2-1/2" 30 60.5 - 67.0 109
90 90 3“ 3“ 30 66.7 - 79.0 120
NAMBUK Cable Gland
Copyright by NAMBUK Electric Co., LTD. 2008
Armoured Cable Gland
Increase Safety Type
Type of Explosion-proof
Increase Safety (Ex e II)
Technical Data
Type A4e Cable Type Steel Tape Armoured
Gland
MaterialBrass
Sealing
AreaOuter Sheath
Seal
MaterialThermoplastic
Elastomer For Area
Indoor
Outdoor
Hazardous Area
Ordering Number & Dimension Accessory
Cable
Gland
Size
Entry Thread 'C'Thread
Length 'D'
Cable Dia 'A'
Min Max
Cable Dia 'B'
Min Max
Max Dia
'E' Shrouds, Earth Tags,
Locknuts, Entry
Thread Seals - see
accessory page.
Metric NPT PF
20S 20 1/2" 1/2" 15 6.5 - 11.6 6.1 - 11.6 26.5
20 20 1/2" 1/2" 15 10.0 - 13.9 6.5 - 13.9 30.0
25 25 3/4" 3/4" 15 11.6 - 19.9 11.1 - 19.9 39.9
32 32 1" 1" 15 19.0 - 26.2 17.0 - 26.2 45.5
40 40 1-1/4" 1-1/4" 15 25.0 - 32.1 22.0 - 32.1 55.4
50S 50 1-1/2" 1-1/2" 15 27.5 - 38.1 29.5 - 38.1 61.0
50 50 2" 2" 15 33.1 - 44.0 35.6 - 44.0 66.5
63S 63 2“ 2“ 15 40.1 - 50.0 40.1 - 49.9 77.6
63 63 2-1/2" 2-1/2" 15 47.2 - 55.9 47.2 - 55.9 83.2
75S 75 2-1/2" 2-1/2" 15 43.5 - 61.9 52.8 - 61.9 88.7
75 75 3“ 2-1/2" 15 49.8 - 67.9 59.1 - 67.9 94.2
90 90 3“ 3“ 15 64.0 - 79.3 66.6 - 79.3 120.7
Armoured Cable Gland
General or Regular Type
Technical Data
Type A4 Cable Type Steel Tape Armoured
Gland
MaterialBrass
Sealing
AreaOuter Sheath
Seal
MaterialThermoplastic
Elastomer For AreaIndoor
Outdoor
Ordering Number & Dimension Accessory
Cable
Gland
Size
Entry Thread 'C'Thread
Length 'D'
Cable Dia 'A'
Min Max
Cable Dia 'B'
Min Max
Max Dia
'E' Shrouds, Earth Tags,
Locknuts, Entry
Thread Seals - see
accessory page.
Metric NPT PF
20S 20 1/2" 1/2" 15 6.5 - 11.6 6.1 - 11.6 26.5
20 20 1/2" 1/2" 15 10.0 - 13.9 6.5 - 13.9 30.0
25 25 3/4" 3/4" 15 11.6 - 19.9 11.1 - 19.9 39.9
32 32 1" 1" 15 19.0 - 26.2 17.0 - 26.2 45.5
40 40 1-1/4" 1-1/4" 15 25.0 - 32.1 22.0 - 32.1 55.4
50S 50 1-1/2" 1-1/2" 15 27.5 - 38.1 29.5 - 38.1 61.0
50 50 2" 2" 15 33.1 - 44.0 35.6 - 44.0 66.5
63S 63 2“ 2“ 15 40.1 - 50.0 40.1 - 49.9 77.6
63 63 2-1/2" 2-1/2" 15 47.2 - 55.9 47.2 - 55.9 83.2
75S 75 2-1/2" 2-1/2" 15 43.5 - 61.9 52.8 - 61.9 88.7
75 75 3“ 2-1/2" 15 49.8 - 67.9 59.1 - 67.9 94.2
90 90 3“ 3“ 15 64.0 - 79.3 66.6 - 79.3 120.7
NAMBUK Cable Gland
Copyright by NAMBUK Electric Co., LTD. 2008
Accessories / Option for Cable Gland
Shroud (PVC / LSF) Earth TagsShroud totally encloses the gland
body and forms an effective seal
down onto the cables's overall
The shroud has an extensive
taper at the cable end and
effectively seals the smallest size
of cable.
The shroud forms a protective
seal to the exposed metal parts
of the gland when used in highly
corrosive atmospheres.
Standard material is PVC
The earth tag which fits onto the thread
at the terminal end is manufactured from
brass strip 1.6mm thick
By including this earth tag, a more
effective bearing surface is presented to
the apparatus or other conducting parts.
The earth tag provide and earth bond
connection as specified in BS 6121:Pt5.
Earth bond connections are specified in
IEE wiring regulations and relevant
Codes of Practice. If fault current rating
of the cable exceeds the short circuit
rating specified in the table below, an
integral earth gland is recommended.
Metric Entry Thread Seals Earth
Tag
Size
Short Circuit Rating Symmetrical Fault
Current (kA) for 1sFor IP rating across the interface
between the equipment and
gland, it is essential to fit a
metric entry thread seal.
Standard material is nylon.
Standard High Breaking Capacity
20 3.06 4.4
25 4.00 4.8
32 5.40 5.2
EeCFC Seal 40 7.20 9.8
50 10.40 11.4For inner seal use with cable
certain exhibit "cold flow"
characteristics
63 10.40 12.0
75 10.40 14.3
LocknutAvailable to suit all thread forms
offered with cable glands.
Standard material is brass
Zinc plated mild steel locknuts are a
cost effective alternative to the brass
locknuts, but be used only in dry, low
humidity conditions.
Earth Washer (Serrated Type)For Lead Covered Steel Wire
Armoured Cable
Cold Flow
The latest IEC 60079 requires that certain cable types which employ materials which can exhibit significant "cold flow"
characteristics which could have adverse effects on the protection of the apparatus, is to be used, a suitable cable entry
device should be employed. "EeCFC Seal" is to avoid this problem designed that eliminating any damage to the cable
sheath as opposed to conventional compression seal which usually require the cable gland to be fully tightened on
installation.
<Compression Type Seal> <Reduce Damage Type Seal>
If you need more information, contact us please. ⇨
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
Conduit Fittings
Packing Cable Gland Type of Explosion-proof
Flameproof ( Ex d IIC )
<EG>
<EGC>
<EPG>
<EUG>
Application
These cable glands are ;
EPG is designed to provide flameproof packing type
cable gland for corrugated steel armoured cable
EUG is fit to the threaded conduit entries and used
for the purpose of leading the unarmoured cable at
open area.
Available in metric and NPT inlet threadsFeatures
Compact size for close nesting of cables.
Easy and fast to install
Hex design for easy wrenching
Compliance & Certification
IEC 60079-0, 1
Certified by KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others.
◎ EG
Hub Size Cable Size Cat No. A B C D
1/2" 16C 7- 09∅ ∅ EG 16-9
1/2" 42 97 409- 12∅ ∅ EG 16-12
3/4" 22C 11- 14∅ ∅ EG 22-14 3/4" 49 104 44
1" 28C 14- 19∅ ∅ EG 28-19 1" 59 110 48
1-1/4" 36C 19- 24∅ ∅ EG 36-24 1-1/4" 76 147 62
1-1/2" 42C 24- 28∅ ∅ EG 42-28 1-1/2" 88 156 71
2" 54C 28- 33∅ ∅ EG 54-33 2" 102 182 87
2-1/2" 70C33- 39∅ ∅ EG 70-39
2-1/2" 122 200 103Standard Materials 39- 44∅ ∅ EG 70-44
Die Cast Aluminium3" 82C
44- 49∅ ∅ EG 82-493" 142 225 117
49- 54∅ ∅ EG 82-54Standard Finish 4" 104C 54- 69∅ ∅ EG 104-69 4" 182 264 149Stove enamelled grayish blue
If you want another color, contact us
please.
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
◎ EGC
Hub Size Cable Size Cat No. A B C D
1/2" 16C 07- 09∅ ∅ EGC 16-9
1/2" 42 97 4009- 12∅ ∅ EGC 16-12
3/4" 22C 11- 14∅ ∅ EGC 22-14 3/4" 49 104 44
1" 28C 14- 19∅ ∅ EGC 28-19 1" 59 110 48
1-1/4" 36C 19- 24∅ ∅ EGC 36-24 1-1/4" 76 147 62
1-1/2" 42C 24- 28∅ ∅ EGC 42-28 1-1/2" 88 156 71
2" 54C 28- 33∅ ∅ EGC 54-33 2" 102 182 87
2-1/2" 70C33- 39∅ ∅ EGC 70-39
2-1/2" 122 200 103Standard Materials 39- 44∅ ∅ EGC 70-44
Die Cast Aluminium3" 82C
44- 49∅ ∅ EGC 82-493" 142 225 117
49- 54∅ ∅ EGC 82-54
Standard Finish 4" 104C 54- 69∅ ∅ EGC 104-69 4" 182 264 149
Stove enamelled grayish blue
◎ EPG
Hub Size Cat NoDimension Cable Diameter
A B C 1 2 3
1/2" 16C EPG A16 117 22 49 09- 12∅ ∅ 13- 19∅ ∅ 19- 24∅ ∅
3/4" 22C EPG A22 121 22 56 11- 16∅ ∅ 15- 23∅ ∅ 21- 28∅ ∅
1" 28C EPG A28 128 27 64 16- 21∅ ∅ 22- 28∅ ∅ 27- 33∅ ∅
1-1/4" 36C EPG A36 130 27 79 20- 28∅ ∅ 26- 37∅ ∅ 32- 42∅ ∅
1-1/2" 42C EPG A42 168 27 89 28- 33∅ ∅ 35- 43∅ ∅ 41- 48∅ ∅
Standard Materials 2" 54C EPG A54 170 27 109 33- 44∅ ∅ 43- 55∅ ∅ 48- 60∅ ∅
2-1/2" 70C EPG A70 184 38 129 44- 57∅ ∅ 54- 70∅ ∅ 59- 75∅ ∅Steel
Option : Stainless steel
Brass 3" 82C EPG A82 196 38 149 57- 69∅ ∅ 68- 81∅ ∅ 73- 86∅ ∅
Standard Finish 4" 104C EPG A104 199 38 169 69- 80∅ ∅ 78- 93∅ ∅ 78- 98∅ ∅
Stove enamelled grayish blue
◎ EUG
<EUG>
Hub Size Cable Size Cat No. A B C D E
1/2" 16C 07- 09∅ ∅ EUG 16-9
13 1/2" 76 22 4109- 11∅ ∅ EUG 16-11
3/4" 22C10- 13∅ ∅ EUG 22-13
18 3/4" 77 22 4913- 15∅ ∅ EUG 22-15
1" 28C14- 18∅ ∅ EUG 28-18
23 1" 83 27 5418- 20∅ ∅ EUG 28-20
1-1/4" 36C18- 23∅ ∅ EUG 36-23
28 1-1/4" 84 27 6423- 26∅ ∅ EUG 36-26
1-1/2" 42C23- 28∅ ∅ EUG 42-28
34 1-1/2" 103 27 7528- 31∅ ∅ EUG 42-31
2" 54C27- 34∅ ∅ EUG 54-34
42 2" 105 27 84Standard Materials34- 38∅ ∅ EUG 54-38Steel
Option : Stainless steel
Brass2-1/2" 70C
33- 41∅ ∅ EUG 70-4155 2-1/2" 118 38 100.5
41- 49∅ ∅ EUG 70-49
3" 82C41- 52∅ ∅ EUG 82-52
64 3" 121 38 11852- 60∅ ∅ EUG 82-60Standard Finish
4" 104C55- 65∅ ∅ EUG 104-65
85 4" 129 38 139Stove enamelled grayish blue 65- 75∅ ∅ EUG 104-75
SECTION - 6F
Accessories
SECTION 6F
Accessories INDEXModel Product Description
Certification for
Explosion-proofPage
EXRA Reducer
Ex d IIC 6F - 1
EXRB Reducer
EXRC Reducer
EXSC Socket
SP Steel Plug
AP Aluminium Plug
SN Nipple
SL Lock Nut
6F - 2
SB Bushing
SIB Insulated Bushing
SGB Grounding Bushing
SDC Clamp
SDS Saddle
SCB Clamp Back
SUB U-Bolt
SHC Pipe Hanger
SHG Pipe Hanger
SHC Pipe Clamp
LCCI Cable Tray Conduit Clamp
LCCO Cable Tray Conduit Clamp
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
Conduit Fitting
Accessories
Type of Explosion-proof Flameproof (Ex d IIC)
Standard Materials Standard Finish
Carbon Steel
Aluminium Alloy (AP Series)
Zinc Electroplate
Natural (AP Series)
If you want another color, contact us please.
Types Reducer Types Socket Plug Nipple
Design Design
Conduit Size Large : Male
Small : Female
Large : Male
Small : Female
Large : Female
Small : Male
Conduit
SizeLarge Small
3/4” 22 1/2” 16 EXRA 2216 EXRB 2216 EXRC 2216
16 1/2” EXSC 16 SP 16 AP 16 SN 161” 28
1/2” 16 EXRA 2816 EXRB 2816 EXRC 2816
3/4” 22 EXRA 2822 EXRB 2822 EXRC 2822
1-1/4” 36
1/2” 16 EXRA 3616 EXRB 3616 EXRC 3616
22 3/4” EXSC 22 SP 22 AP 22 SN 223/4” 22 EXRA 3622 EXRB 3622 EXRC 3622
1” 28 EXRA 3628 EXRB 3628 EXRC 3628
1-1/2” 42
1/2” 16 EXRA 4216 EXRB 4216 EXRC 4216
28 1” EXSC 28 SP 28 AP 28 SN 283/4” 22 EXRA 4222 EXRB 4222 EXRC 4222
1” 28 EXRA 4228 EXRB 4228 EXRC 4228
1-1/4” 36 EXRA 4236 EXRB 4236 EXRC 4236
36 1-1/2” EXSC 36 SP 36 AP 36 SN 36
2” 54
1/2” 16 EXRA 5416 EXRB 5416 EXRC 5416
3/4” 22 EXRA 5422 EXRB 5422 EXRC 5422
1” 28 EXRA 5428 EXRB 5428 EXRC 5428
42 1-1/2” EXSC 42 SP 42 AP 42 SN 421-1/4” 36 EXRA 5436 EXRB 5436 EXRC 5436
1-1/2” 42 EXRA 5442 EXRB 5442 EXRC 5442
2-1/2” 70
3/4” 22 EXRA 7022 EXRB 7022 EXRC 7022
54 2” EXSC 54 SP 54 AP 54 SN 541” 28 EXRA 7028 EXRB 7028 EXRC 7028
1-1/4” 36 EXRA 7036 EXRB 7036 EXRC 7036
1-1/2” 42 EXRA 7042 EXRB 7042 EXRC 7042
70
2-1/2”EXSC 70 SP 70 AP 70 SN 702” 54 EXRA 7054 EXRB 7054 EXRC 7054
3” 82
1” 28 EXRA 8228 EXRB 8228 EXRC 8228
1-1/4” 36 EXRA 8236 EXRB 8236 EXRC 8236
82 3” EXSC 82 SP 82 AP 82 SN 821-1/2” 42 EXRA 8242 EXRB 8242 EXRC 8242
2” 54 EXRA 8254 EXRB 8254 EXRC 8254
2-1/2” 70 EXRA 8270 EXRB 8270 EXRC 8270
92
3-1/2”EXSC 92 SP 92 AP 92 SN 92
3-1/2” 92
1-1/4” 36 EXRA 9236 EXRB 9236 EXRC 9236
1-1/2” 42 EXRA 9242 EXRB 9242 EXRC 9242
2” 54 EXRA 9254 EXRB 9254 EXRC 9254
104 4” EXSC 104 SP 104 AP 104 SN 1042-1/2” 70 EXRA 9270 EXRB 9270 EXRC 9270
3” 82 EXRA 9282 EXRB 9282 EXRC 9282
4” 104
1-1/2” 42 EXRA 10442 EXRB 10442 EXRC 10442
2” 54 EXRA 10454 EXRB 10454 EXRC 10454
2-1/2” 70 EXRA 10470 EXRB 10470 EXRC 10470
3” 82 EXRA 10482 EXRB 10482 EXRC 10482
3-1/2” 92 EXRA 10492 EXRB 10492 EXRC 10492
Conduit Fitting
Copyright by NAMBUK Electric Co., LTD. 2004
Types Lock Nut Bushing Insulated Bushing Grounding Bushing
Design
Standard Materials Steel or Zinc Alloy Zinc Alloy
Standard Finish Zinc Electroplate
Conduit Size Catalog Number
16 1/2” SL 16 SB 16 SIB 16 SGB 16
22 3/4” SL 22 SB 22 SIB 22 SGB 22
28 1” SL 28 SB 28 SIB 28 SGB 28
36 1-1/2” SL 36 SB 36 SIB 36 SGB 36
42 1-1/4” SL 42 SB 42 SIB 42 SGB 42
54 2” SL 54 SB 54 SIB 54 SGB 54
70 2-1/2” SL 70 SB 70 SIB 70 SGB 70
82 3” SL 82 SB 82 SIB 82 SGB 82
92 3-1/2” SL 92 SB 92 SIB 92 SGB 92
104 4” SL 104 SB 104 SIB 104 SGB 104
Types Clamp Saddle Clamp Back U-Bolt with Nut
Design
Standard Materials Cast Iron or Steel Steel
Standard FinishCast Iron : Hot Dip Galvanized
Steel : Zinc ElectroplateHot Dip Galvanized Zinc Electroplated
Conduit Size Catalog Number
16 1/2” SDC 16 SDS 16 SCB 16 SUB 16
22 3/4” SDC 22 SDS 22 SCB 22 SUB 22
28 1” SDC 28 SDS 28 SCB 28 SUB 28
36 1-1/2” SDC 36 SDS 36 SCB 36 SUB 36
42 1-1/4” SDC 42 SDS 42 SCB 42 SUB 42
54 2” SDC 54 SDS 54 SCB 54 SUB 54
70 2-1/2” SDC 70 SDS 70 SCB 70 SUB 70
82 3” SDC 82 SDS 82 SCB 82 SUB 82
92 3-1/2” SDC 92 SDS 92 SCB 92 SUB 92
104 4” SDC 104 SDS 104 SCB 104 SUB 104
Types Pipe Hanger Pipe Clamp Cable Tray Conduit Clamp
Design
Standard Materials SteelBody : Cast Iron
Hook : Steel
Standard Finish Zinc Electroplate Hot Dip Galvanized
Conduit Size Catalog Number
16 1/2” SHC 16 SHG 16 SPC 16 LCCI 16 LCCO 16
22 3/4” SHC 22 SHG 22 SPC 22 LCCI 22 LCCO 22
28 1” SHC 28 SHG 28 SPC 28 LCCI 28 LCCO 28
36 1-1/2” SHC 36 SHG 36 SPC 36 LCCI 36 LCCO 36
42 1-1/4” SHC 42 SHG 42 SPC 42 LCCI 42 LCCO 42
54 2” SHC 54 SHG 54 SPC 54 LCCI 54 LCCO 54
70 2-1/2” SHC 70 SHG 70 SPC 70 LCCI 70 LCCO 70
82 3” SHC 82 SHG 82 SPC 82 LCCI 82 LCCO 82
92 3-1/2” SHC 92 SHG 92 SPC 92 LCCI 92 LCCO 92
104 4” SHC 104 SHG 104 SPC 104 LCCI 104 LCCO 104
Fire Protection
Copyright by NAMBUK Electric Co., LTD. 2004
Detector
EXFD Series
< EXFD >
Type of Explosion-proof Flameproof (Ex d IIB T4)
Application
EXFD Series detectors are used ;
in oil refinery, power electric plant and chemical
plant where hazardous locations.
Features
The enclosures are composed of the main body,
cover inner barrier and terminal box joined together
with threaded and spigot joints.
The cover can be unscrewed by releasing one
locking bolt, and the replacement of the fuse links is
easily done.
Two type - Bimetal & Electronic type.
Dimension
Standard Materials
Body : Cast aluminium alloy
Cover : Cast aluminium alloy
Standard Finish
MUNSELL No. 7.5BG 6/1.5
MUNSELL No. 7.5R 3/12 (Red)
If you want another color, contact us please.
CertificationCompliance Certified by KOSHA (Korea Occupational Safety &
Health Agency), KOFEIC (Korea Fire Equipment
Inspection Corporation), KGS (Korea Gas Safety
Corporation), and the others.
IEC 60079-0, 1
Fire Protection Law of Korea
Technical Data
Catalog No. Rating Operation TypeOperating Temp.
( )℃Weight (g)
Classification of
Explosion-proof
EXFD-60 DC 24V / 100mA Bimetal 60 Ex d IIB T4
EXFD-90 DC 24V / 1A Bimetal 90 Ex d IIB T4 H2
EXED-60 DC 24V / 100mA Electronic 60 Ex d IIB T4
EXED-90 DC 24V / 100mA Electronic 90 Ex d IIB T4
If you need more information, contact us please. ⇨