Dilator Tip Flexibility
Improved Coating
The Navigator HD Ureteral Access Sheath retains the characteristics of the flexible tip of the current Navigator Ureteral Access Sheath, while still providing a stiffer shaft for ease of placement.
The hydrophilic coating on both Navigator HD Ureteral Access Sheath and dilator show an improved coefficient of friction and an improved durability over Navigator Ureteral Access Sheath and Cook Flexor™ Ureteral Access Sheath after undergoing 20 cycles of placement through a tight simulated stricture.
0
5
10
15
20
25
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Gra
ms
Forc
e
Cycle
Average Cycle Force: Competitive Dilators
0
5
10
15
20
25
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Gra
ms
Forc
e
Cycle
Average Cycle Force: Competitive Sheaths
Color Key: Navigator Sheath Navigator HD Sheath Flexor Sheath
Navigator™ HDUreteral Access Sheath
TecHNicAl DATA SHeeT
Po
un
ds
of
Forc
e
0.6
0.5
0.4
0.3
0.2
Navigator HD12Fr
Navigator HD11Fr
Navigator13Fr
Navigator11Fr
Flexor14Fr
Navigator HD13Fr
Flexor12Fr
Dilator Tip Stiffness
Data on file at Boston Scientific Corporation and will be made available upon request.
Navigator is a registered trademark of Boston Scientific Corporation or its affiliates. All other trademarks are property of their respective owners.
Caution: Federal Law (USA) restricts this device to sale by or on the order of a physician. Refer to package insert provided with the product for complete Indications for Use, Contraindications, Warnings, Precautions, Adverse Events, and Instructions prior to using this product.
Hub Design
The Navigator™ HD Ureteral Access Sheath requires less force to insert through a simulated stricture when compared to Navigator Ureteral Access Sheath and to Cook Flexor™ Ureteral Access Sheath, indicating a smoother transition from guidewire to dilator and from dilator to sheath.
One handed latch engagement: The Navigator HD Sheath can be successfully assembled with the dilator in almost any rotation relative to the sheath hub vs Cook Flexor Sheath can only be successfully assembled when the dilator is aligned rotationally with the sheath hub.
Navigator HD Sheathcook Flexor Sheath
Lower Insertion Force
Flexor12/14Fr
Navigator HD12/14Fr
Navigator 13/15Fr
Po
un
ds
of
Forc
e
0.35
0.30
0.25
0.20
0.15
0.10
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
Po
un
ds
of
Forc
e
Flexor12/14Fr
Navigator HD12/14Fr
Navigator13/15Fr
Guidewire to Dilator Insertion Force Dilator to Sheath Insertion Force
Color Key: Navigator Sheath Navigator HD Sheath Flexor Sheath