24
Fisher-Francel Regulators Natural Gas Regulators Pressure Regulators Relief Valves Slam Shuts Remote Operations Control

Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

  • Upload
    hadat

  • View
    254

  • Download
    4

Embed Size (px)

Citation preview

Page 1: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

Fisher-Francel Regulators

Natural Gas RegulatorsPressure Regulators • Relief Valves • Slam Shuts • Remote Operations Control

Page 2: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

ON THE COVERFisher-Francel Natural Gas products shown are

Types 627, 299 (center), 399A-161EB, FloBoss 500

and OSE with slam shut.

Page 3: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

1

Since the birth of the natural gas industry, Fisher Controls has been a leader in regulator

product design, engineering applications support, value for the dollar and customer

satisfaction. Today, no other regulator manufacturer in the world offers more products and

services dedicated to the natural gas industry than Fisher.

With the most complete line of pressure regulators and a worldwide distribution network,

Fisher has the products you need in stock locally, ready for delivery or shipment directly

from a Fisher factory. Our global capabilities include an experienced sales and support

team consisting of more than 2,000 technical experts available to serve you from nearly

200 offices throughout the world. Wherever you are, you can count on the Fisher

commitment to product integrity, reliability, safety and performance – and a level of

support that no other supplier can equal.

Call on Fisher to help you enhance your asset management strategy by reducing inventory

and other cost-effective measures. Even your toughest natural gas regulation challenges

are no match for Fisher equipment, local service and support. At any time, anywhere in

the world, Fisher can help you manage your process better.

Our pledge to you...

Fisher-Francel Regulators

Page 4: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

22

InformationWhat’s New . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Premier products from wellhead to pilot light . . . . . . . . .4

Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

A worldwide network of sales supportand supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Certification and the Quality standards of ISO 9001, DVGW, CEN and Fisher . . . . . . . . . . . . . . . . . . . . .5

Cost-effective training for cost-effective solutions . . . . . . . . . . . . . . . . . . . . . . . . . .6

Flow measurement and control . . . . . . . . . . . . . . . . . . . . . .6

Fisher-Francel, world leaders in regulators . . . . . . . . . . .7

Regulators and ProductsPressure299 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

1098-EGR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

99 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

399A-161EB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

627 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

627F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

310-32A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

630 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

133 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

133HP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

66 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

S402 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

S102C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

S252/S254 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

399A-6365/6358 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

S300 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

S301F/D Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

S200 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Y600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Y690 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

67 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

1301F/G Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

64 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

1367 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

Slam Shuts299SO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

S208/S209 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

Relief252 Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

289 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

289P-6358 or 289P-6365 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

1805 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

1805P-6358 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

1808 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

H100/H200 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

63EG Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

66R & 66RR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

414 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

FrancelASOFLEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

B Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

CMAX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

DRPN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

OSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

MPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

ROD AGNI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

REGAL 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

Transmission Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

Distribution Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

Cabinets / Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

Service Pits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

Regulator/Relief Selection Table . . . . . . . . . . . . . . . . . . . .20

Table of Contents

Page 5: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

3

What’s New299 SERIES

These pressure reducing regulators

are especially suited for fixed factor

or PFM applications requiring high

accuracy.

(page 8)

399A-161EB

This new, high performance

pressure reducing regulator

provides increased accuracy as

well as higher setpoints.

(page 8)

S102C

A direct-operated, spring loaded

regulator which provides higher

relief capacity in a variety of

residential, commercial and

industrial applications.

(page 11)

252 FILTER

Available in stainless steel or

aluminum construction to provide

micron filtration for various

applications in the natural gas

industry.

(page 14)

299SO

This regulator is the same as the

299 Series with the addition of VSX

Slam-Shut technology.

(page 14)

S208/S209

Quick reacting pressure reducing

regulators with the Type VSX Slam-

Shut module. They are typically

used for industrial or commercial

applications where use of relief

valves is not an option.

(page 14)

OSE

The OSE Slam-Shut is used to

totally and rapidly cut the gas flow

when network pressure is too high

and/or too low.

(page 18)

133HP

This direct-operated regulator is

ideal for district regulator use,

monitors, and industrial and

commercial applications.

(page 10)

Page 6: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

4

Premier productsfrom wellhead to pilot light

From the industry’s premier supplier.Fisher Controls offers more regulators and relief valves than any

other manufacturer in the world. From regulators that handle

high pressure gas flows to low pressure house service

applications, you can trust that Fisher’s resources, engineering

expertise, industry experience and dedication to quality ensure

maximum profitability for gas utility customers.

As a Fisher customer, you will find that our natural gas

regulators and relief valves incorporate only the latest in

high-tech engineering technology. Many of our regulators, such

as the 630 Series, 99 Series and Type 61 pilot have become

industry standards for performance and extended service life.

New products to meet your changing needs.In order to best meet customers’ needs, Fisher is always

updating and expanding its regulator line. On page three of this

brochure you’ll find our What’s New section, featuring several

new products for a variety of applications.

Delivery.For the right regulator at the right time, Fisher delivers. At any

given time, the Fisher Controls Representative Network has

more regulators in stock than most regulator manufacturers can

ship in a total year. Fisher will also supply any product (up to 80

percent of our product line) on an overnight basis if you’re

needing it in an emergency. For streamlining or reducing

inventory, rely on Fisher to establish monthly or even more

frequent shipments. Because our people and systems are

geared to meeting your requirements on time, your best source

for natural gas regulators is your local Fisher Representative.

Page 7: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

5

With over 2,000 technical experts to serve you from nearly 200

locations throughout the world, the Fisher sales and service

network is one of the largest in the industry. Whether you need

an emergency replacement regulator or are working on a

utility’s long-range plan for growth and expansion, our

Representatives respond quickly and professionally. This kind of

sales support, combined with a dedication to pursuing the latest

in advanced technology for all our products, makes Fisher the

recognized leader in regulator supplies by the natural gas

industry.

No matter what type of application problem or question you

have, Fisher is your regulator resource. The majority of our

applications personnel are degreed engineers, specialists in

specifying pressure regulator solutions. Our Representatives are

dedicated to providing the products and services that help you

reach your goals, including a comprehensive training program

available locally or at Fisher facilities. Total support — before

and after the sale — is what you’ll find at Fisher.

State-of-the-art products. Individually tested.Fisher regulator and relief valve manufacturing facilities are

equipped with the latest in technology. Excellence in

engineering is the hallmark of our manufacturing procedures.

Each Fisher regulator or relief valve is individually tested prior to

shipment to ensure that it will perform exactly to customer

specifications. We continuously improve our ability to produce

the highest quality regulators available on the market today.

And Fisher probably has the items you need in local stock or

ready for immediate shipment from a Fisher factory.

A worldwide network of sales support and supplies

Certification–ISO 9001.Improving the quality of our products while increasing customer

satisfaction has always been the priority at Fisher. That’s why

we are proud to bring our customers products that consistently

meet the rigorous standards of quality assurance–ISO 9001

Certification. ISO 9001 standards require that:

■ an effective quality assurance system is in place,

■ equipment is properly calibrated and maintained,

■ proper records are kept,

■ product handling and storage systems are adequate,

■ and personnel training and experience are up to par.

The quality standards of FisherCurrently all Fisher regulator manufacturing and design facilities

are ISO 9001 Certified.

DVGW, CEN and Fisher.In Europe, Fisher is presently involved in and has received DVGW

registration and is pursuing CEN approval for various regulator

products. DVGW registration signifies that registered products

meet common Natural Gas Industry standards. This registration

is also recognized by users outside the European gas industry.

Product schematics and other technical documentation for all

the products listed in this brochure are available in electronic

form on the Fisher Controls Regulator Division Literature

CD-ROM. For your free copy of the CD or printed copies of

technical documentation, call 1-800-558-5853. You can also

e-mail your request to [email protected].

Fisher Controls Regulator Division

Marshalltown IA 50158 USA

(515) 754-3741 (515) 754-3081 (fax)

www.fisher.com/regulators (Internet)

[email protected] (e-mail)

Page 8: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

6

Cost-effective training for cost-effective solutions

Because we at Fisher take training so seriously, certified

instructors in our Fisher-Rosemount Educational Services division

offer a variety of courses to gas industry personnel.

Fisher-Rosemount Educational Services works closely with the

gas utilities industry, providing extensive know-how and natural

gas regulator application training.

The range of training includes an annual Gas Industry Conference,

regularly scheduled factory training relative to natural gas regulator

installation and maintenance, Remote Operations Controllers

(ROC), FloBoss™ and on-site training. The course instruction

covers product application and regulation, as well as measurement

instrumentation and studies on PROVOX® Distributed Control

Systems and other process and application topics.

Training for natural gas regulation topics and more is available at

all of our North America Regional Training Centers, or on-site at

your facility. In addition, self-training programs including videos,

workbooks, tests and computer-based training are available to

keep your staff as current and proficient as possible in all new

and mature technologies.

Fisher’s family of Remote Operations Controllers (ROCs) and

FloBoss™ Flow Computers are designed to meet the wide-

ranging measurement and control needs of the natural gas

industry. These powerful products are ideally suited to

applications at wellheads, meter runs, custody transfer stations,

compressor stations and gate stations. They provide on-site,

round-the-clock monitoring, measurement, totalizing, alarming,

communications and control.

Using the latest microprocessor technology, these products stand

alone or network to a data gathering system. Monitored values

are processed and stored for easy access by personnel in the

field, or can be relayed through telephone, radio, or satellite

transmissions to supervisors and managers at regional and

corporate offices. System integration is simplified because they

are designed to operate with many popular host software

packages.

Both ROC and FloBoss product families feature advanced

hardware and software that make them simple to configure and

operate, easy to customize to the application, modular for faster

upgrading and expansion, and versatile for better integration into

host systems. Built into each unit are AGA flow calculations, PID

control and logic/sequencing control to meet almost any

measurement and control need.

Flow measurement and control for the gas industryTo make field automation projects easier, Fisher and its

Representatives have teamed to create the ROC Integration

Network. The Network has access to hundreds of proven field

automation solutions, developed from a worldwide installed base

of over 10,000 FAS products serving a wide range of applications.

Page 9: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

7

World Leaders in Regulation EquipmentFisher-Francel RegulatorsWith over 130 combined years of expertise, Fisher Controls and

Francel are the world’s leading providers of pressure regulation

equipment for the natural gas industry for both industrial and

residential use. The addition of Francel to the Fisher team has

expanded Fisher’s total product line and provided additional

manufacturing, training and service facilities in more parts of the

world than ever before. This broad line of products, from

transmission through distribution, includes regulators, relief

valves, skids and cabinets, and remote operations controllers in

a variety of sizes, materials and configurations to match almost

any application.

Francel expertise, including slam shut technology, innovations in

natural gas skid design and experience with state-owned utilities

in many countries, is the perfect complement for Fisher

Controls. In addition to product reliability and local service

throughout the world, Fisher-Francel products are manufactured

in facilities certified to ISO 9001 standards, and selected

products are DVGW-certified for European applications.

In addition to traditional Fisher service, support, education and

training, Francel also provides educational opportunities at its in-

house training center in Gallardon, France. There, customers

increase their knowledge and learn more about utilizing products

through a combination of theoretical and practical work under

the close supervision of highly trained course leaders.

Fisher and Francel products have been engineered and

manufactured to meet and exceed the highest international

standards, providing a wide diversity of regulator products for

natural gas applications such as power generation, primary fuel

for major industries, heating large facilities such as schools and

hospitals, and service to homes, just to name a few.

Page 10: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

8

T C D F C/ I DF

C D C/ I FF DF

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1098-EGR End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . .1, 2, 3, 4, 6, 8 x 6, 12 x 6-inch

Reduced Pressure Ranges (10) . . . . . 2-inches wc - 300 psig (5 mbar - 20,7 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .400 psig (28 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron or Steel

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.2:1098-EGR

For accurate control of high capacity gas flow applications, the 1098-EGR has a

Type 1098 diaphragm actuator and spring-to-close Design EGR main valve.

Trim parts can be changed without having to remove the body or actuator

from the line. Excellent choice for low-pressure drop applications.

T C D C/ I FF

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99 SERIESEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-inch

Reduced Pressure Ranges (9) . . . . . . .2-inches wc - 100 psig (5 mbar - 6,9 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,000 psig (69 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron or Steel

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.2:99

For accurate control over widely varying flow rates and supply pressure, the

pilot-operated Type 99 eliminates the need for pressure-compensating meters

by holding a steady pressure from the high-pressure gas main to the meter

inlet and offers versatile pressure ranges at flow capacity.

D C/ I FF DF

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .299End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1/2, 2-inch

Reduced Pressure Ranges (8) . . . . .3-1/2-inches wc - 35 psig (9 mbar - 2,4 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 psig (10,3 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron or Steel

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.2:299

The Type 299 pressure reducing regulator has a wide variety of applications,

including natural gas distribution systems, gas supply to industrial boilers,

furnaces, ovens, mixers, plant air service and has PFM and fixed factor

capabilities. The Type 299 is not an adaptation of existing regulators; instead, it

has a new design of integrated cases and internal registration ports. Now

available with token relief (Type 299TR).

Pressure

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . .399A-161EBEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . .(16 sizes) from 1-12 x 6-inch

Reduced Pressure Ranges (8) . . . . .5-inches wc - 700 psig (12 mbar - 48,3 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1,050 psig (72,4 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron or Steel

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.2:399A-161

The Type 399A-161EB, shown with the Type 252 filter, is a pressure reducing

regulator commonly used in city or district gates and low-pressure commercial

meters. Top entry design allows for in-line inspection and maintenance. The

Type 161EB pilot is similar to the Type 161, but has a taller spring case which

provides higher accuracy.

Page 11: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

9

T TRANSMISSION

C CITY GATE

D DISTRICT GATE

F FARM TAP

C/I COMMERCIAL/INDUSTRIAL

FF FIXED FACTOR/PFM

H RESIDENTIAL SERVICE

A INSTRUMENT AIR

R RELIEF VALVE

S SLAM SHUT

DF DIN FLANGED

T F C/ I DF D F C/ I FF DF

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .627FEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3⁄4, 1, 2-inch

Outlet Pressure Range . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 100 psig (0,34 - 6,9 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 psig (17,2 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Ductile Iron or Steel

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:627F

For accurate pressure control, the Type 627F has a factory-installed Type 6351F

pilot. The regulator spring case can be rotated in any of four positions and is

an excellent choice for fixed-factor applications.

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . .627 SERIES End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3⁄4, 1, 2-inch

Reduced Pressure Ranges (6) . . . . . . . . . . . . . . . . . .5 - 500 psig (0,34 - 34,5 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2,000 psig (138 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Ductile Iron or Steel

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:627

The Type 627 Series of Farm Tap regulators offer easy in-line maintenance and

installation. A rubber cap relief operation indicator pops off when the internal

relief valve opens, indicating that the valve has opened since the last inspection.

T F

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .630 End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1, 2-inch

Reduced Pressure Ranges (10) . . . . . . . . . . . . . . . . .3 - 500 psig (0,21 - 34,5 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1,500 psig (103 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron or Steel

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:630

The Type 630 Big Joe® direct-operated regulators are available in either spring-

loaded or pressure-loaded constructions. A main feature is a wide range of

flow capabilities. Main uses are in farm tap and first-stage reduction on high

pressure transmission lines.

T C D C/ I DF

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .310A-32AEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1, 2, 3, 4 x 6-inch

Reduced Pressure Ranges (3) . . . . . . . . . . . . . . . .10 - 600 psig (0,69 - 41,4 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1,480 psig (102 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Steel

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.2:310A

This pilot-operated regulator includes a Type 32A pilot assembly for pressure-

reducing or wide-open monitoring applications, or two pilots for working

monitor usage on main gas pipelines. Fast response and accurate enough for

turbine start-up and fuel supply applications.

Page 12: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

10

C/I FF H

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .S402End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . .3⁄4 x 3/4, 3/4 x 1, 1 x 1-inch

Reduced Pressure Ranges (6) . . . .4-1/2-in. wc - 2.5 psig (11,2 mbar - 0,17 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125 psig (8,6 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cast Iron

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:S402

The control accuracy of the Type S402 Series provides fixed-factor billing

capabilities throughout the available spring ranges and is specifically

applicable for use in piping systems within the natural gas industry.

PressureD C/ I D C/ I

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .133HPEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-inch

Reduced Pressure Ranges (7) . . . . . . . . . . . . . . . . . . . .2 - 60 psig (0,14- 4,1 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 psig (10,3 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron or Steel

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:133

The Type 133HP self-operated regulator is ideal for the high-pressure, large

capacity loads of district regulator use and for industrial and commercial

applications supplying gas to furnaces, burners, and ovens. A balancing

system enables the regulator to control gas pressure accurately for maximum

combustion efficiency despite varying inlet pressure.

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66 SERIESEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2, 3- to 4-inch

Reduced Pressure Ranges (6) . . . . . . . . . . .2-inch wc - 5 psig (4.98 - 345 mbar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 psig (0,69 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron or Steel

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:66

The direct-operated Type 66 Series offers precise control of low-pressure

industrial gases, as well as a broad range of downstream demand situations.

The Series is available in both vacuum regulator and vacuum breaker

constructions. Flow capacities range up to 187,000 Scfh [5,012 m3/h(n)].

Applications include burner control and tank blanketing.

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . .133 SERIESEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-inch

Reduced Pressure Ranges (9) . . . . . . . 2-inches wc - 10 psig (5 mbar- 0,69 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 psig (4,1 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron or Steel

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:133

The Type 133 Series offers a balanced single port design which eliminates the

necessity for seat-to-seat adjustments for bubble-tight shutoff. The valve seat,

disc and cage can be easily removed for inspection without having to remove

the body from the service line. Applications include supplying gas to furnaces,

burners and other appliances.

C/I

Page 13: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

11

T TRANSMISSION

C CITY GATE

D DISTRICT GATE

F FARM TAP

C/I COMMERCIAL/INDUSTRIAL

FF FIXED FACTOR/PFM

H RESIDENTIAL SERVICE

A INSTRUMENT AIR

R RELIEF VALVE

S SLAM SHUT

DF DIN FLANGED

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .S102CEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3/4, 1, 1-1/4, 1-1/2-inch

Reduced Pressure Ranges (5) . . . . . .3-1/2 -in. wc - 2.5 psig (8 mbar - 0,17 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 psig (10 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:S100C

The Type S102C is a self-operated, spring loaded regulator that provides

economical pressure-reducing control in a variety of residential, commercial

and industrial applications. The Type S102C has internal relief across the

diaphragm to help minimize overpressure.

H C/ I H

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . .S252/S254 SERIESEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3⁄4, 1-inch

Reduced Pressure Ranges (6) . . . . . . .3-1/2-in. wc - 2.5 psig (9 mbar - 0,17 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125 psig (8,6 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Aluminum

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:S250

Designed primarily as a house service regulator for domestic gas installations,

the S252/S254 Series is available in versions with high capacity relief. Easy

access to the orifice and valve disc allows for easy maintenance and

combines well with 175 and 250 meters. Available in either angle or meter bar

body style. Diaphragm and valve disc are made of Nitrile.

C/I FFC/ I DF

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . .399A-6365/6358End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . .(16 sizes) from 1-12 x 6-inch

Relief Set Pressure Ranges (5) . . . . . . . . . . . . . . . . . . .20 - 300 psig (1,4 - 21 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .360 psig (25 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron or Steel

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:399A-6365/6358

This pilot-operated pressure relief valve offers elastomer boot-style design,

reliable performance and easy maintenance. In-line maintenance with top

entry allows for easy removal of trim for inspection and replacement.

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . .S300 SERIESEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1⁄4, 1-1⁄2, 2-inch

Reduced Pressure Ranges (7) . . . . .3-1/2-inches wc - 8 psig (9 mbar - 0,55 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 psig (10,3 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:S300

These compact size, spring-loaded regulators offer internal relief and relief

monitoring constructions available for compliance with code requirements.

The diaphragm and valve disc are constructed of Nitrile.

Page 14: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

12

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Y600 End Connection Size . . . . . .3/4 x 3/4, 3/4 x 1, 1 x 1, 1 x 1-1/4, 1-1/4 x 1-1/4-inch

Reduced Pressure Ranges (5) . . . . . . . . . . .1-inch wc - 7 psig (2 mbar - 0,5 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 psig (10,3 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:Y600

The Type Y600 is a self-operated, spring-loaded regulator that provides

economical pressure-reducing control in a variety of residential, commercial

and industrial applications. The pressure settings and the pilot tube of the

Type Y600 also creates a dynamic boost that helps provide greater capacity.

C/I H C/ I H DF

Pressure

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . .Y690 SERIESEnd Connection Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3/4, 1-inch

Reduced Pressure Ranges (7) . . . . . . . . . 1-inch wc - 7 psig (2,5 mbar - 0,5 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 psig (10,3 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Ductile Iron or Steel

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:Y690

The Type Y690 is a direct operated regulator used for accurate pressure control

on very low-pressure systems. Downstream pressure is sensed through a pilot

tube, thus no external control line is required.

C/I FF

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . .S301F/D SERIESEnd Connection Size . . . . .3/4 x 3/4, 1 x 1, 1-1/4 x 1-1/4, 1-1/2 x 1-1/2, 2 x 2-inch

Reduced Pressure Range (5) . . . . . . . . . . . . . . . .4 - 125 psig (0,27 bar - 8,6 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125 psig (8,6 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.2:S301

This compact pilot-operated regulator has a factory-installed Type 6351 pilot

with pre-piped tubing. It has the capacity for small industrial and commercial

meter set applications. It is used in fixed-factor applications where high

accuracy is required. Both external and internal downstream pressure

registration constructions.

C/I FF

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . .S200 SERIESEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1⁄2, 2-inch

Reduced Pressure Range (7) . . . . . . . .2-inches wc - 10 psig (5 mbar - 0,69 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 psig (10,3 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron Steel

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:S200

The S200 Series are high-capacity, accurate regulators that respond to quick

load changes and are available with or without internal relief, integral monitor

and monitor constructions. First choice for commercial and industrial service

applications.

Page 15: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

13

T TRANSMISSION

C CITY GATE

D DISTRICT GATE

F FARM TAP

C/I COMMERCIAL/INDUSTRIAL

FF FIXED FACTOR/PFM

H RESIDENTIAL SERVICE

A INSTRUMENT AIR

R RELIEF VALVE

S SLAM SHUT

DF DIN FLANGED

A

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . .1301F/G SERIES End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1⁄4-inch

Reduced Pressure Ranges (3) . . . . . . . . . . . . . . . . . .10 - 225 psig (0,69 - 16 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6,000 psig (414 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brass or Stainless Steel

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:1301

These direct-operated regulators are used for applications requiring reduction

of high-pressures for small capacity flow and feature a durable stainless steel

diaphragm. They can be installed in any positon.

A

A

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64 SERIESEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1⁄2-inch

Reduced Pressure Ranges (7) . . . . . . . . . . . . . . . . . . .3 - 150 psig (0,2 - 10,3 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250 psig (17,2 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Aluminum

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:64

Spring-loaded, self-operated regulators for constant reduced pressure. Body

side connection for plugged or unplugged control pressure registration or tap

for a pressure gauge. The Type 64R comes with internal relief.

A

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 SERIESEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1⁄4-inch

Reduced Pressure Ranges (4) . . . . . . . . . . . . . . . . . . .3 - 100 psig (0,21 - 6,9 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250 psig (17,2 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Aluminum or Stainless Steel

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:67

This compact, easy-to-maintain regulator has an optional handwheel for easy

adjustment of set point. The 67 Series offers accurate and reliable regulation

with high stability. A token capacity internal relief valve provides overpressure

protection. Applications include use on airsets in instrument systems.

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1367End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4-inch

Outlet Pressure Range . . . . . . . . . . . . . . . . . . . . . . . . . . .5 - 35psig (0,34 - 2,4 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2,000 psig (138 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Relief Valve

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Aluminum

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:1367

The Type 1367 is a high-pressure instrument supply system designed for

regulation and overpressure protection in one complete package. The system

provides installation flexibility and is capable of continuous moisture removal.

Page 16: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

14

D C/ I FF S DF C/ I FF S DF

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .299SOEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1/4, 1-1/2, 2-inch

Reduced Pressure Ranges . . . . . . . .3-1/2-inches wc - 35 psig (9 mbar - 2,4 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 psig (10, 3 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot with Slam Shut Option

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Ductile Iron

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.2:299

A new product from Fisher, the Type 299SO has a wide variety of applications

for distribution of natural gas, fuel gas and air. The regulator is the same as the

Type 299 Series with the addition of VSX Slam-Shut technology.

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . .S208/S209End Connection Size . . . . . . . . . .1-1/4 x 1-1/4, 1-1/2 x 1-1/2, 1-1/2 x 2, 2 x 2-inch

Reduced Pressure Ranges (13) . . . .3-1/2 inches wc - 5 psig (9 mbar - 0,34 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125 psig (8,6 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct with Slam Shut Option

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ductile Iron

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:S208

The quick reacting Types S208 and S209 pressure reducing regulators with the

Type VSX shutoff module are typically used in an industrial or commercial

installation to minimize the shock effect of sudden downstream load changes.

The Type 299 is not an adaptation of existing regulators; instead, it has a new

design of integrated cases and internal registration ports.

Slam Shuts/ Reliefs

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289 SERIESEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1⁄4, 3⁄4, 1, 2-inch

Relief Set Pressure Ranges (13) . . . . . . 3-inches wc -75psig (7,5 mbar - 5,2 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100 psig (6,9 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Aluminum or Cast Iron

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.4:289

This relief valve provides smooth throttling action to minimize pressure surges

during emergency operation. Its small size allows for easy installation in limited

spaces, and high flow rates can be achieved with minimum pressure buildup.

RC/I

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . .252 FILTEREnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4-inch

Maximum Working Pressure (Aluminum) . . . . . . . . . . . . . . 2,120 psig (148 bar)

Maximum Working Pressure (Stainless Steel) . . . . . . . . . . . .2,750 psig (190 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Filter

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Aluminum or Stainless Steel

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90.1:252

Designed for high or low pressure pilot supply and general filtering

applications, the Type 252 Filter is engineered to provide filtration through the

filter and where the filter cartridge is supported. Standard construction

includes 316 SST, making the Type 252 Filter resistant to sour gas and

compliant with NACE as standard.

Page 17: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

15

T TRANSMISSION

C CITY GATE

D DISTRICT GATE

F FARM TAP

C/I COMMERCIAL/INDUSTRIAL

FF FIXED FACTOR/PFM

H RESIDENTIAL SERVICE

A INSTRUMENT AIR

R RELIEF VALVE

S SLAM SHUT

DF DIN FLANGED

R

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . .1808 SERIESEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-inch

Relief Set Pressure Range . . . . . . . . . . . . . . . . . . . . . . . 5 - 125 psig (0,3 - 8,6 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 psig (10,3 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron or Steel

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.4:1808

An economical, compact design relief valve, the Type 1808 is offered with

either a Type 6358 or Type 6365 pilot and is available in either a globe style or

angle style. Upstream control line construction is available to provide wide-

open relief flow capacity.

TYPE NUMBER . . . . . . . . . . . . . . . . . . .289P-6358 OR 289P-6365 End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1, 2-inch

Relief Set Pressure Ranges (3) . . . . . . . . . . . . . . . . .0.5 - 100 psig (0,03 - 6,9 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110 psig (7,6 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aluminum or Cast Iron

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.4:289P-6358

This pilot-operated valve offers accurate flow and pressure regulation when

coupled with a high gain pilot. High flow rates are achieved with only a small

increase in buildup pressure.

R R

R

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . .1805 SERIESEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3⁄4, 1, 1-1⁄2, 2-inch

Relief Pressure Ranges (3) . . . . . . . . . . . . . . . . . . . . . .5 - 125 psig (0,34 - 8,6 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 psig (10,3 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.4:1805

Used in farm tap applications, this economical relief valve is needed between

first- and second-stage regulators. It allows for tight shutoff, easy

maintenance, simple adjustment and complete venting.

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . .1805P-6358End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-inch

Reduced Pressure Ranges (3) . . . . . . . . . . . . . . . . . .10 - 100 psig (0,69 - 6,9 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110 psig (7,6 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.4:1805P-6358

This throttle valve gives accurate, low-cost relief and consists of a Type 1805P

main valve and a Type 167AFR pilot. The relief pressure settings are adjusted

by rotating the pilot spring adjustment screw.

Page 18: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

16

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . .H100-H200 SERIES End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4, 3⁄4, 1-inch

Fixed Relief Set Pressures (16) . . . . . . . . . . . . . . . . . . .25 - 350 psig (1,7 - 24 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .420 psig (29 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brass

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.4:H120, 71.4:H200

This direct-operated “pop” relief valve comes with preset and pinned spring

retainers. Simply operated with wide spring selection, it is used mainly on

pneumatic control lines of air drills, jackhammers and other similar

equipment.

R

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . .63EG SERIES End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . .1, 2, 3, 4, 6, 8 x 6, 12 x 6-inch

Relief Set Pressure Ranges (5) . . . . . . . . . . . . . . . . . . .10-300 psig (0,69 - 21 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .360 psig (25 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron, Steel or Stainless Steel

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.4:63EG

This pilot-operated throttling pressure relief valve offers high capacity flow

capabilities. Available with the Type 6365 and 6358 pilots.

R DF

R

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . .66R & 66RREnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2, 3, 4-inch

Relief Set Pressure Ranges (6) . . . . . . . . . .2-inch wc - 3psig (5 mbar - 0,21 bar)

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 psig (0,69 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron, Steel or Stainless Steel

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:66R

The 66R and 66RR are low-pressure, high-capacity throttling relief valves for

overpressure protection or inlet back pressure control. Higher set pressure ranges

are available with optional springs, diaphragm plates and other internal parts.

Relief

R

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .414 End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1, 2, 3, 4, 6-inch

Relief Set Pressure Ranges (3) . . . . . . . . . . . . . . .100 - 1,200 psig (6,9 - 82,7 bar)

Maximum Allowable Pressure . . . . . . . . . . . . . . . . . . . . . . . .1440 psig (99,3 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Steel

Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.4:414-6305

This pilot-operated backpressure regulator or relief valve provides high-

pressure capability for both liquids and gases. The construction is suitable

where pressures on the valve outlet will be essentially atmospheric.

Page 19: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

17

T TRANSMISSION

C CITY GATE

D DISTRICT GATE

F FARM TAP

C/I COMMERCIAL/INDUSTRIAL

FF FIXED FACTOR/PFM

H RESIDENTIAL SERVICE

A INSTRUMENT AIR

R RELIEF VALVE

S SLAM SHUT

DF DIN FLANGED

D S D F C/ I H S

Pressure/Francel

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ASOFLEXEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DN 25, 50, 80,100, 150

Outlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 mbar-16 bar

Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0,7 - 25 bar

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A216WCB

Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NT ASOFLEX 9704

ASOFLEX is a silent pilot pressure regulator with built-in slam shut shut-off

valve. Silent operation range is <75/80dBA.

F S

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DRPNEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DN 25

Outlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 - 4 bar

Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .up to 25 bar

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A216WCB

Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NTA DRPN 9604

DRPN is a direct operated pressure regulator for natural gas distribution

networks and transmission applications. Incorporates slam shut shut-off

technology.

D S DF

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .CMAXEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DN 25, 80, 150

Outlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 - 4 bar

Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0,7 - 25 bar

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A216WCB

Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NTA C MAX 9607

CMAX is a medium range pilot operated regulator with slam shut shut-off

capability suitable for natural gas distribution networks and commercial

applications such as boiler room natural gas pressure regulation.

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B SERIESEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3/4 x 1-1/4-inch

Outlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 mbar - 4 bar

Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0,1 - 5 bar

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Zinc Aluminum

Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NTA B 9604

Spring loaded two-stage domestic regulator design maintains constant outlet

pressure. Used in residential, commercial or industrial applications.

Page 20: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

18

Pressure/FrancelT C/I S DF

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .OSE End Connection Size . . . . . . . . . . . . . . .1, 2, 3, 4, 6-inch (DN 25, 50, 80, 100, 150)

Release Point Range . . . . . . . . . . . . . 4-inch wc - 1,044 psig (0,10 mbar - 72 bar)

Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1,450 psig (100 bar)

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Steel

Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.6:OSE

The OSE Slam Shut valve is used to protect transmission and distribution

networks and gas mains in the industrial sector. Slam shut features internal

bypass for simple manual startup.

C/I H

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ROD AGNIEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Meter

Outlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(Connection) 19 - 39 mbar

Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0,5 bar

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Limit Flow Valve

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Steel

Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(M) ROD 0 12

ROD AGNI is natural gas solution for residential service. ROD AGNI replaces

the combination of a gas meter and regulator for customers with limited gas

flow requirements. After a predetermined flow rate is passed, the regulator

shuts off gas flow automatically. The regulator can be reset manually.

C/I H S

D S D F

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .MPSEnd Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DN 25, 50, 80,100

Outlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0,3 - 60 bar

Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 - 70 bar

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A216WCB

Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NTA MPSE 9604

The MPS is a low-noise pilot operated gas pressure regulator for natural gas

transport lines. Its design is suitable for compact installations. Diaphragm is

only moving part.

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .REGAL 2End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1, 1-1/4 x 1-1/4-inch

Outlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 mbar - 0,34 bar

Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0,5 - 10 bar

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct

Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Steel

Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NTA REG2 9605

REGAL 2 is a direct operated, spring loaded regulator with a built-in slam shut

shut-off valve. Typically used in natural gas supply applications in apartments,

commercial and municipal buildings.

Page 21: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

19

T TRANSMISSION

C CITY GATE

D DISTRICT GATE

F FARM TAP

C/I COMMERCIAL/INDUSTRIAL

FF FIXED FACTOR/PFM

H RESIDENTIAL SERVICE

A INSTRUMENT AIR

R RELIEF VALVE

S SLAM SHUT

DF DIN FLANGED

Pressure/Francel

TRANSMISSION STATIONSFisher and Francel regulators, gas metering and pressure reducing stations are

specified and used in natural gas transmission lines throughout the world.

Our engineers design transmission skids to meet customer specifications with

complete gas control systems including pressure regulation, filtration, gas

heating, odorization and monitoring. A typical double line Offtake Station is

capable of reducing 70 bar pressure to 4 bar at a flow rate of 1,500 SCMH.

T

DISTRIBUTION STATIONSFrancel distribution stations feature silent pressure regulators and slam shut

technology. Francel manufactures and assembles complete Offtake Stations

or District Regulating Stations to customer specifications. These stations are

shipped as “skids” ready for installation. A typical District Regulating Station is

capable of reducing pressure from 19 bar to 4 bar at a flow of 2,000 SCMH.

D

D C/ I H T D C C/ I H

CABINETS / MODULESFrancel designs and manufactures a wide range of fitted, painted metal

cabinets and modules in various sizes. Cabinets typically enclose regulators

and related pressure reducing components. Cabinets and modules may be

specified for aesthetic, environmental, or security reasons.

SERVICE PITSDomestic or commercial end users may require compact regulator service

pits or vaults to contain and protect natural gas service assemblies consisting

of regulator, vent, and piping. Service pits are buried underground but are

accessible for necessary utility maintenance.

Page 22: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

20

TransmissionCity Gate

District GateFarm Tap

Commercial/IndustrialFixed Factor

Residential ServiceInstrument Air

Relief ValveSlam Shut

Page ProductNo. Bulletin**

Reduced Pressure Rangesand Relief Set-Points*Number within ( ) indicatesspring ranges.

Fisher/FrancelType or Series

End Connection Sizes MaximumInlet

Pressure*

Further Reference

(8) 3-1/2"wc-35 / 9(m)-2,4 ■ ■ ■ 299 1-1/2", 2" 150 / 10,3 8 71.2:299 (10) 2"wc-300 / 5(m)-20,7 ■ ■ ■ ■ 1098-EGR 7 sizes from 1" to 12"x6" 400 / 27,6 8 71.2:1098-EGR(9) 2"wc-100 / 5(m)-6,9 ■ ■ ■ ■ ■ 99 2" 1,000 / 69 8 71.2:99(8) 5"wc-700 / 0,34-48,3 ■ ■ ■ ■ ■ 399A-161EB/161Y 16 sizes from 1" to 12"x6" 1,050 / 72,4 8 71.2:399A-161(6) 5-500 / 0,34-34,5 ■ ■ ■ 627 3/4", 1", 2" 2,000 / 138 9 71.1:627

5-100 / 0,34-6,9 ■ ■ ■ ■ 627F 3/4", 1", 2" 100 / 6,9 9 71.1:627F(3) 10-600 / 0,69-41,4 ■ ■ ■ ■ 310A-32A 1", 2", 3", 4"x6" 1,480 / 102 9 71.2:310A (10) 3-500 / 0,21-34,5 ■ ■ 630 1", 2" 1,500 / 103 9 71.1:630(9) 2"wc-10 / 5(m)-0,69 ■ ■ 133 2" 60 / 4,1 10 71.1:133(7) 2-60 / 0,14-4,1 ■ ■ 133HP 2" 150 / 10,3 10 71.1:133 (6) 4"wc-5 / 10(m)-0,34 ■ 66 2", 3", 4" 25/ 1,7 10 71.1:66(6) 4-1/2"wc-2.5 / 11(m)-0,17 ■ ■ ■ S402 3/4"x3/4", 3/4"x1", 1"x1" 125 / 8,6 10 71.1:S402(5) 3-1/2"wc-2.5 / 9(m)-0,17 ■ ■ S102C 3/4", 1", 1-1/4", 1-1/2" 150 / 10,3 11 71.1:S100C(6) 3-1/2"wc-2.5 / 9(m)-0,17 ■ S252/S254 3/4", 1" 125 /8,6 11 71.1:S250(5) 20-300 / 1,4-20,7 ■ 399A-6365/6358 16 sizes from 1 to 12"x6" 360 / 25 11 71.1:399A-6365(7) 3-1/2"wc-8 / 9(m)-0,55 ■ ■ S300 1-1/4", 1-1/2", 2" 150 / 10,3 11 71.1:S300(5) 2-20 / 0,14-1,4 ■ ■ S301F/D 3/4", 1", 1-1/4", 1-1/2", 2" 125 / 8,6 12 71.2:S301(7) 2"wc-10 / 5(m)-0,69 ■ ■ S200 1-1/2", 2" 150 / 10,3 12 71.1:S200(5) 1"wc-7 / 2(m)-0,5 ■ ■ Y600 5 sizes from 3/4"x3/4" to 1-1/4"x1-1/4" 150 / 10,3 12 71.1:Y600(7) 1"wc-7 / 2(m)-0,5 ■ ■ Y690 3/4", 1" 150 / 10,3 12 71.1:Y690(4) 3-100 / 0,21-6,9 ■ 67 1/4" 250 / 17,2 13 71.1:67(3) 10-500 / 0,69-34,5 ■ 1301F/G 1/4" 6,000 / 414 13 71.1:1301(7) 3-200 / 0,21-13,8 ■ 64 1/2" 250 / 17,2 13 71.1:64

5-35 / 0,34-2,4 ■ 1367 1/4" 2,000 / 138 13 71.1:1367(8) 3-1/2"wc-5 / 9(m)-0,34 ■ ■ ■ ■ 299SO 1-1/4", 1-1/2", 2" 150 / 10,3 14 71.2:299(13) 3-1/2"wc-5 / 9(m)-0,34 ■ ■ ■ S208/209 4 sizes from 1-1/4"x1-1/4" to 2"x2" 125 / 8,6 14 71.1:S208(13) 3"wc-75 / 7(m)-5,17 ■ 289 1/4", 3/4", 1", 2" 100 / 6,9 14 71.4:289

10-100 / 0,69-6,9 ■ 289P-6358 or 6365 1", 2" 110 / 7,6 15 71.4:289P-6358(3) 5-125 / 0,34-8,6 ■ 1805 3/4", 1", 1-1/2", 2" 150 / 10,3 15 71.4:1805(3) 10-100 / 0,69-6,9 ■ 1805P-6358 2" 110 / 7,6 15 71.4:1805P-6358

5-125 / 0,34-8,6 ■ 1808 2" 150 / 10,3 15 71.4:1808(16) 25-300 / 1,7-24 ■ H100-H200 1/4", 3/4", 1" 420 / 29 16 71.4:H120 / H200(5) 3-300 / 0,69-20,7 ■ 63EG 7 sizes from 1" to 12" x 6" 360 / 25 16 71.4:63EG(6) 2"wc-3 / 5(m)-0,21 ■ 66R & 66RR 2", 3", 4" 10 / 0,69 16 71.1:66R(3) 100-1,200 / 6,9-82,7 ■ 414 1", 2", 3", 4", 6" 1,440 / 99 16 71.4:414-6305

10(m)-16 bar ■ ■ ASOFLEX DN 25, 50, 80, 100,150 0,7-25 bar 17 NT ASOFLEX 97049(m)-4 bar ■ ■ ■ B SERIES 3/4" x 1-1/4" 0,1-5 bar 17 NTA B 96042-4 bar ■ ■ CMAX DN 25, 80,150 0,7-25 bar 17 NTA C MAX 96072-4 bar ■ ■ DRPN DN 25 up to 25 bar 17 NTA DRPN 9604

(11) 0.3-1,045 / 0,02-72 ■ ■ ■ OSE 1", 2", 3", 4", 6" 1,450 / 100 18 71.6:OSE0,3-60 ■ ■ MPS DN 25, 50, 80 100 7-70 bar 18 NTA MPSE 960419 (m)-39 (m) bar ■ ■ ROD AGNI meter 0,5 bar 18 (M) ROD 0 128 (m)- 0,34 bar ■ ■ ■ REGAL 2 1", 1-1/4" x 1-1/4" 0,5-10 bar 18 NTA REG2 9605

Fisher-Francel Natural Gas Regulator Selection TableTypical Applications

* Reduced Pressure Ranges, Relief Set Points and

Maximum Inlet Pressures are expressed in psig/bar

or water column (wc) and millibar (m).

** Please request our free literature CD-ROM to view

full details of products. See page 5 of this brochure

for ordering information.

Page 23: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

ISO 9001

TrainingSales Support

Service

Remote Operations Controller ROCRemote Drive

Relief Valves Regulators

Fisher Solutions Delivery

Page 24: Natural Gas Regulators - Dominion ... - Dominion Industrialdominion.com.mx/cat/fisher/reguladores-de-gas-natural.pdf · Even your toughest natural gas regulation challenges ... Transmission

D350358X012 ©Fisher Controls International, Inc. All rights reserved.Printed in the U.S.A.