12
Product ID: KL.1904 Name: Mortice Bathroom Lock Lockcase(mm) A=87 Backset (mm) B=55 Centres C=78 Follower (mm) 8 Latch Bolt Reversible Mechanism Bathroom Function Forend Finish SSS Rebates available (mm) KL.1904A - 13 KL.1904B - 25 Options Radius Forend KL.1904RC

Name: Mortice Bathroom Lock Options Radius Forend KL.1904RC€¦ · CERTIFICATE No CF 5234 KCC ARCHITECTURAL Page 5 of 6 Signed Issued: 23rd May 2014 Valid to: 22nd May 2019 KCC ARCHITECTURAL

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Name: Mortice Bathroom Lock Options Radius Forend KL.1904RC€¦ · CERTIFICATE No CF 5234 KCC ARCHITECTURAL Page 5 of 6 Signed Issued: 23rd May 2014 Valid to: 22nd May 2019 KCC ARCHITECTURAL

Product ID: KL.1904

Name: Mortice Bathroom Lock

Lockcase(mm) A=87

Backset (mm) B=55

Centres C=78

Follower (mm) 8

Latch Bolt Reversible

Mechanism Bathroom Function

Forend Finish SSS

Rebates available (mm) KL.1904A - 13 KL.1904B - 25

Options Radius Forend KL.1904RC

Page 2: Name: Mortice Bathroom Lock Options Radius Forend KL.1904RC€¦ · CERTIFICATE No CF 5234 KCC ARCHITECTURAL Page 5 of 6 Signed Issued: 23rd May 2014 Valid to: 22nd May 2019 KCC ARCHITECTURAL

Sashlock has a cylinder to latch function where both latch and deadbolt can be withdrawn

by cylinder key or thumbturn.

copyright © 2009 KCC Architectural

Page 3: Name: Mortice Bathroom Lock Options Radius Forend KL.1904RC€¦ · CERTIFICATE No CF 5234 KCC ARCHITECTURAL Page 5 of 6 Signed Issued: 23rd May 2014 Valid to: 22nd May 2019 KCC ARCHITECTURAL

This certificate is the property of Warrington Certification Limited, part of Exova (UK) Ltd. Registered office: Lochend Industrial Estate, Newbridge, Midlothian, EH28 8PL, UK. Registered in Scotland, No. SC 70429

Page 1 of 2

Notified body No. 1121Warrington Certification Limited, Holmesfield Road, Warrington, Cheshire, WA1 2DS, UK

Certificate of constancy of performance

1121-CPR-AG5096

In compliance with Regulation 305/2011/EU of the European Parliament and of the Council of 9 March 2011 (the Construction Products Regulation or CPR), this certificate applies to the construction product

KL1904 Bathroom Lock

Intended use: For use on fire/smoke compartmentation doors

Essential characteristics Performance Harmonised technical

specificationMechanical test evidence:189851 & 190463Fire test evidence: 144028 Iss 2

Self closing 5.4.2 Closing force

5.1.2 Re-latching force of latch bolt

Grade 5 = 200kg door mass with 25N maximum closing force.

>2.5N

EN 12209: 2003 / AC 2005

Durability of self closing5.3.1 Durability of latch action

Grade X = 200,000 cycles with 120N side load on latch bolt.

Ability to maintain the door in the closed position and not contribute to its spread of fire

Grade 1

Control of Dangerous substances

If a reference to dangerous substances is added in the table ZA.1, the following claim is suggested:Pass: the materials in the hinge do not contain or release any dangerous substances in excess of the maximum levels specified in existing European material standards or any national regulations (1)

Page 4: Name: Mortice Bathroom Lock Options Radius Forend KL.1904RC€¦ · CERTIFICATE No CF 5234 KCC ARCHITECTURAL Page 5 of 6 Signed Issued: 23rd May 2014 Valid to: 22nd May 2019 KCC ARCHITECTURAL

This certificate is the property of Warrington Certification Limited, part of Exova (UK) Ltd. Registered office: Lochend Industrial Estate, Newbridge, Midlothian, EH28 8PL, UK. Registered in Scotland, No. SC 70429

Page 2 of 2

Certificate of constancy of performance

1121-CPR-AG5096 Produced for

KCC Door Hardware & Security Solutions Ltd Unit 1

Westgate Business Park Ballymount Dublin 24

and produced in the manufacturing plant

J/030 This is coded format and the information is held by the Notified Body

This certificate attests that all provisions concerning the assessment and verification of constancy of performanceand the performances described in Annex ZA of the standard(s)

EN 12209:2003/AC 2005 under system 1 of AVCP are applied and that

the product fulfils all the prescribed requirements set out above.

This certificate was first issued on 23/05/14 and will remain valid as long as the test methods and/or factory production control requirements included in the harmonised standard, used to assess the performance of the declared characteristics, do not change, and the product, and the manufacturing conditions in the plant are not modified significantly.

Paul Duggan Certification Manager

Warrington Certification Ltd

Page 5: Name: Mortice Bathroom Lock Options Radius Forend KL.1904RC€¦ · CERTIFICATE No CF 5234 KCC ARCHITECTURAL Page 5 of 6 Signed Issued: 23rd May 2014 Valid to: 22nd May 2019 KCC ARCHITECTURAL

This certificate is the property of Warrington Certification Limited, part of Exova (UK) Ltd. Registered office: Lochend Industrial Estate, Newbridge, Midlothian, EH28 8PL, UK. Registered in Scotland, No. SC 70429

CERTIFICATE OF APPROVALNo CF 5234

This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products

The undermentioned products of

KCC ARCHITECTURAL Unit 1 Westgate Business Park, Ballymount, Dublin 24, Ireland

Tel: 00 353 1 4567 421

Have been assessed against the requirements of the Technical Schedule(s) denoted below and are approved for use subject to the conditions

appended hereto: ______________________________________________________________________________

CERTIFIED PRODUCT TECHNICAL SCHEDULE

KCC ARCHITECTURAL FOCUS CONTRACT LOCKS

TS23 The Contribution of Locks and Latches to The Performance of Fire Resisting DoorsetsAnd TS 31 The Contribution Of Emergency Exit Devices, Operated By A Lever Handle Or Push Pad, To The Performance Of Fire Resisting Door Assemblies

Signed and sealed for and on behalf of CERTIFIRE

Sir Ken Knight Issued: 23rd May 2014 Chairman - Management Council Valid to: 22nd May 2019 Page 1 of 6

Page 6: Name: Mortice Bathroom Lock Options Radius Forend KL.1904RC€¦ · CERTIFICATE No CF 5234 KCC ARCHITECTURAL Page 5 of 6 Signed Issued: 23rd May 2014 Valid to: 22nd May 2019 KCC ARCHITECTURAL

This certificate is the property of Warrington Certification Limited, part of Exova (UK) Ltd. Registered office: Lochend Industrial Estate, Newbridge, Midlothian, EH28 8PL, UK. Registered in Scotland, No. SC 70429

CERTIFICATE No CF 5234KCC ARCHITECTURAL

Page 2 of 6 Signed Issued: 23rd May 2014Valid to: 22nd May 2019

KCC ARCHITECTURAL FOCUS CONTRACT LOCKS

1. The locks and latches covered by this certificate are all steel cased. This approval relates to the following specific locks:

KL1901 Sashlock KL1902 Dead lock KL1904 Bathroom Lock KL1905 Mortice Latch KL1907 Nightlatch KL1907AT Nightlatch KL1908 Escape Lock

All models approved in 55mm back set with 20 mm and 24 mm width forend options.

2. This certification is designed to demonstrate compliance of the product or system specifically with Approved Document B (England and Wales), Section D of the Technical Standards (Scotland) and Technical Booklet E (N. Ireland). If compliance is required to other regulatory or guidance documents there may be additional considerations or conflict to be taken into account.

3. This approval relates to the use of the above locks/latches in contributing to the fire resistance performance of timber based doorsets and metallic based doorsets, as defined in BS EN 1634-1 or BS 476: Part 22: 1987.

4. This approval relates to their use with the following door assemblies:-

Latched and unlatched, intumescent sealed door assemblies consisting of timber faced and edged leaves with timber, cellulosic or mineral cores in timber frames having a fire resistance up to 60 minutes (Code ITT).

Latched and unlatched, door assemblies consisting of uninsulated or insulated metal door assemblies in metal frames with or without intumescent seals having a fire resistance up to 240 minutes (Code IMM/MM).

5. The locks are approved on the basis of:

i) Initial type testing to EN 1634-1 and EN 12209/EN 179 (where relevant) ii) An appraisal against TS23 or TS31 (where relevant)

iii) Certification of quality management system to ISO 9001: 2008. iv) Inspection and surveillance of factory production control v) On-going audit testing in accordance with TS23 or TS31 requirements

Page 7: Name: Mortice Bathroom Lock Options Radius Forend KL.1904RC€¦ · CERTIFICATE No CF 5234 KCC ARCHITECTURAL Page 5 of 6 Signed Issued: 23rd May 2014 Valid to: 22nd May 2019 KCC ARCHITECTURAL

This certificate is the property of Warrington Certification Limited, part of Exova (UK) Ltd. Registered office: Lochend Industrial Estate, Newbridge, Midlothian, EH28 8PL, UK. Registered in Scotland, No. SC 70429

CERTIFICATE No CF 5234KCC ARCHITECTURAL

Page 3 of 6 Signed Issued: 23rd May 2014Valid to: 22nd May 2019

KCC ARCHITECTURAL FOCUS CONTRACT LOCKS

6. This approval is applicable only to the specified locks/latches used with door assemblies of proven fire resistance (as defined in BS EN 1634-1 or BS 476: Part 22: 1987) and, when fitted to timber based doorsets, using appropriate intumescent protection. The required protection for both 30 and 60 minute applications will be 2 mm thick intumescent sheet material around the lock case and a bedding of the same type andthickness of Interdens material behind the forend and strike plate. Failure to install the protection will invalidate this certificate.

7. Lock assemblies not incorporating a latching mechanism shall only be fitted to proven unlatched door assemblies.

8. The locks/latches should not be fitted higher than 1100 mm from the finished floor level of the surrounding floors.

9. Only the KL1908 Escape lock is approved for use as an emergency exit device by TS 31 ever Handle Or Push

single leaf doorsets with the approved accessories detailed within the classifications section of this certificate.

10. The approval relates to on-going production. Product and/or its immediate packaging is

name or name and mark, together with the CERTIFIRE certificate number and application where appropriate.

11. Timber doorsets shall be installed in accordance with BS 8214: 2008.

Page 8: Name: Mortice Bathroom Lock Options Radius Forend KL.1904RC€¦ · CERTIFICATE No CF 5234 KCC ARCHITECTURAL Page 5 of 6 Signed Issued: 23rd May 2014 Valid to: 22nd May 2019 KCC ARCHITECTURAL

This certificate is the property of Warrington Certification Limited, part of Exova (UK) Ltd. Registered office: Lochend Industrial Estate, Newbridge, Midlothian, EH28 8PL, UK. Registered in Scotland, No. SC 70429

CERTIFICATE No CF 5234KCC ARCHITECTURAL

Page 4 of 6 Signed Issued: 23rd May 2014Valid to: 22nd May 2019

KCC ARCHITECTURAL FOCUS CONTRACT LOCKS

The following table shows the acceptable doorset types and fire resistance periods:

Approved Door TypeClass IMM MM TT ITT ITM ITCFD20FD30FD60FD90FD120FD240E 20EI 20E 30EI 30E 60EI 60E 90EI 90E 120EI 120E 240EI 240

See CERTIFIRE Technical Schedules for designation of doorset types i.e. ITT etc.

Key: - approved

- Not approved

Page 9: Name: Mortice Bathroom Lock Options Radius Forend KL.1904RC€¦ · CERTIFICATE No CF 5234 KCC ARCHITECTURAL Page 5 of 6 Signed Issued: 23rd May 2014 Valid to: 22nd May 2019 KCC ARCHITECTURAL

This certificate is the property of Warrington Certification Limited, part of Exova (UK) Ltd. Registered office: Lochend Industrial Estate, Newbridge, Midlothian, EH28 8PL, UK. Registered in Scotland, No. SC 70429

CERTIFICATE No CF 5234KCC ARCHITECTURAL

Page 5 of 6 Signed Issued: 23rd May 2014Valid to: 22nd May 2019

KCC ARCHITECTURAL FOCUS CONTRACT LOCKS

Approved lock/latch models and classifications.

KL1901 Sashlock - BS EN 12209: 2003

KL1902 Dead Lock - BS EN 12209: 2003

KL1904 Bathroom Lock - BS EN 12209: 2003

KL1905 Mortice Latch- BS EN 12209: 2003

KL1907 Nightlatch - BS EN 12209: 2003

KL1907AT Nightlatch - BS EN 12209: 2003

3 X 5 1 0 F 3 B C 2 0

3 X 5 1 0 F 3 B C 0 0

3 X 5 1 0 F - B G 2 0

3 X 5 1 0 F - B 0 2 0

3 X 5 1 0 F - B 0 2 0

3 X 5 1 0 F 2 B B 2 0

Page 10: Name: Mortice Bathroom Lock Options Radius Forend KL.1904RC€¦ · CERTIFICATE No CF 5234 KCC ARCHITECTURAL Page 5 of 6 Signed Issued: 23rd May 2014 Valid to: 22nd May 2019 KCC ARCHITECTURAL

This certificate is the property of Warrington Certification Limited, part of Exova (UK) Ltd. Registered office: Lochend Industrial Estate, Newbridge, Midlothian, EH28 8PL, UK. Registered in Scotland, No. SC 70429

CERTIFICATE No CF 5234KCC ARCHITECTURAL

Page 6 of 6 Signed Issued: 23rd May 2014Valid to: 22nd May 2019

KCC ARCHITECTURAL FOCUS CONTRACT LOCKS

Approved lock/latch models and classifications (continued).

KL1908 Escape Lock - BS EN 179: 1998 + A1: 2001

The lock is certified for use on single leaf doorsets only with the following accessories:

KF5312/2001 19mm Lever Furniture

Further Information

Further information regarding the details contained in this certificate may be obtained from KCC Architectural (Tel: 00 353 1 4567 421).

Further information regarding CERTIFIRE certification and other approved products can be obtained from CERTIFIRE (Tel: 01925 646777).

3 7 6 1 1 3 3 2 A

Page 11: Name: Mortice Bathroom Lock Options Radius Forend KL.1904RC€¦ · CERTIFICATE No CF 5234 KCC ARCHITECTURAL Page 5 of 6 Signed Issued: 23rd May 2014 Valid to: 22nd May 2019 KCC ARCHITECTURAL

  

1  

 

Construction Products Regulation 2011 

DECLARATION OF PERFORMANCE 

 

DoP NO. KCC‐010   1. Unique identification code of the product‐type: KL1900 Series Mortice Locks BS 55mm 

 2. Type, batch or serial number or any other element allowing identification of the construction product as required under Article 11(4) of the CPR: KL1901 Mortice Sashlock, KL1904 Mortice Bathroom Lock, KL1905 Mortice Plain Latch, KL1902, Mortice Deadlock, KL1907 Mortice Nightlatch 

 3. Intended use or uses of the construction product, in accordance with the applicable harmonised technical specification, as foreseen by the manufacturer: For use on fire and smoke compartmentation doors, when fitted in accordance with the manufacturer's fitting instructions. 

 4. Name, registered trade name or registered trade mark and contact address of the manufacturer as required under Article 11(5):  KCC Architectural, Unit 1,  Westgate Business Park, Ballymount,  Dublin 12, Ireland  5. Where applicable, name and contact address of the authorised representative whose mandate covers the tasks specified in Article 12(2): N/A  6. System or systems of assessment and verification of constancy of performance of the construction product as set out in CPR, Annex V:  System 1  7. In case of the declaration of performance concerning a construction product covered by a harmonised standard. EN12209: 2003 incorporating Corrigendum No 1 Notified product certification body No. 1121 performed the determination of the product type on the basis of type testing (including sampling); initial inspection of the manufacturing plant and of the factory production control and continuous surveillance; assessment and evaluation of factory production control; and issued the certificate of constancy of performance of the product.  8. European Technical Assessment: N/A  

Page 12: Name: Mortice Bathroom Lock Options Radius Forend KL.1904RC€¦ · CERTIFICATE No CF 5234 KCC ARCHITECTURAL Page 5 of 6 Signed Issued: 23rd May 2014 Valid to: 22nd May 2019 KCC ARCHITECTURAL

  

2  

 9. Declared Performance 

Essential characteristic Self closing 

Performance  Harmonised technical  specification 

5.4.2 Closing force  Grade 5, Up to 200 kg door mass, 25 N max. closing force 

EN 12209: 2003 incorporating Corrigendum No 1 5.1.2 Re‐latching force of 

latch bolt Greater than 2.5 N 

Essential characteristic Self closing 

Performance  Harmonised technical  specification 

5.3.1 Durability of latch action 

Grade X, 200,000 test cycles, 120 N load on latch bolt 

EN 12209: 2003 incorporating Corrigendum No 1 Ability to maintain the door 

in the closed position and not contribute to the spread of fire 

Grade 1 

Dangerous Substances Annex ZA3   

The materials in the product(s) do not contain or release any dangerous substances in excess of the maximum levels specified in existing European material standards or any national regulations 

  

10. The performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 9. This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 4.  Signed for and on behalf of the manufacturer by:     

  Chris Kilpatrick Managing Director  Date of issue: 1st July 2013  KCC Architectural, Unit 1, Westgate Business Park, Ballymount, Dublin 12 Ireland