8
VALVES & RISER EQUIPMENT

NAFFCO - fakhribrothers.com · NAFFCO Fire hose rack is located inside buildings at the wet or dry riser outlet. It features a rack in which hangs the lay flat fire hose (30m). An

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: NAFFCO - fakhribrothers.com · NAFFCO Fire hose rack is located inside buildings at the wet or dry riser outlet. It features a rack in which hangs the lay flat fire hose (30m). An

VALVES & RISER EQUIPMENT

Page 2: NAFFCO - fakhribrothers.com · NAFFCO Fire hose rack is located inside buildings at the wet or dry riser outlet. It features a rack in which hangs the lay flat fire hose (30m). An

An Introduction to NAFFCO National Fire Fighting and Manufacturing FZCO (NAFFCO) is amongst the world’s largest manufacturers and full solution providers of Fire Fighting equipment, fire protection systems, fire alarm, security systems and safety engineering under one roof.

Dedicated to the science of fire fighting, NAFFCO was established with a vision to be the world’s most recognized fire Protection Company through quality and development to save lives and properties. Headquartered in Dubai, UAE, NAFFCO has spanned the globe by serving over 108 countries worldwide.

The numerous projects executed by NAFFCO in both the private and government sectors throughout the globe are classic examples of its professional competency. These projects include residential buildings, commercial edifices (e.g. schools, hospitals, malls, sports stadiums, etc.), industrial manufacturing plants, power generation stations, and oil and gas facilities. As a provider of total fire protec-tion systems, NAFFCO undertakes turnkey projects from design, supply, installation, testing and commissioning of various systems like fire detection, fire alarm, fire suppression, and fire fighting sys-tems which our customers find it very convenient to have all their system requirements under one roof provided by NAFFCO.

NAFFCO has been consistently maintaining ISO 9001 Quality Man-agement System certified by UL, BV and LPCB. The company also has got certified for ISO 14001 Environmental Management systems and BS OHSAS 18001 for Occupational safety by UL DQS.

NAFFCO implemented top notch ERP “Oracle” Systems by adopt-ing best business practices to enhance efficiency and transparency by controlling key operations with continuous improvement.

The company’s reputation for quality and reliability is globally ac-claimed. Its innovative fire protection and fire fighting products are certified by international bodies like LPCB, BSI, SAI Global, UL and FM. Its product range includes different kinds of fire extinguishers, custom - made fire cabinets, heavy - duty fire hoses and reels, high capacity powerful fire pumps, mobile fire fighting systems includ-ing CAF systems, fire - rated doors, fire detection & alarm systems,

CCTV, ambulances, extendable mobile hospitals, platform vehicles, rescue vehicles, fire trucks, and most advanced Airport Rescue & Fire Fighting (ARFF) vehicle.

Taking into consideration the increasing market demand for sever-al products and services, NAFFCO expands its venture in the pas-sive fire protection, CCTV, fire alarm, and security systems. Some of the recent expansions include the launching of new manufactur-ing divisions for fire - rated doors and HDPE pipes and fittings.

NAFFCO is associated with the globally renowned international companies in the fire protection industry such as Esser, Secu-tron, Megalights, Evax, Fike, Central, Shield, Mueller, Giacomini, RB Pumps, Bombas, Ideal Pumps, Joslyn Pumps, Peerless Pumps and more.

The company is well known for its very strong engineering team that ensures that their innovative designs are based on the stand-ards of the National Fire Protection Association (NFPA). It also has an equally competent and dedicated maintenance team that pro-vides a 24/7 service to ensure the efficiency of the fire protection systems for its clients. NAFFCO offers annual and semi - annual maintenance contracts. Moreover, we also provide after - sales ser-vice, spare parts and training.

In recognition to the success of its business growth, NAFFCO has been awarded with the prestigious Mohammed Bin Rashid Al Mak-toum Business Award for excellence in exports in 2005 and for excellence in manufacturing in 2006 and 2010. Furthermore, NAF-FCO received the Dubai Quality Appreciation in 2008 which bears witness to its constant focus towards business excellence and the quality of services it provides.

NAFFCO’s mission is to empower customer to secure life, property and business by delivering high quality and innovative fire protec-tion solutions and knowledge using world class manufacturing pro-cesses through best engineering practice and expand it worldwide.

www.naffco.com2

Page 3: NAFFCO - fakhribrothers.com · NAFFCO Fire hose rack is located inside buildings at the wet or dry riser outlet. It features a rack in which hangs the lay flat fire hose (30m). An

LANDING VALVESGENERAL SPECIFICATIONSApplicable Standards - BS 5041 - 1 :1987

Body - Copper Alloy to BS EN 1982

Hand Wheel - Cast Iron to BSEN 1561

Outlet - Female Instantaneous to BS 336 : 2010

Working Pressure - 15 Bar (Max)

Test Pressure - 22.5 Bar

OBLIQUE LANDING VALVE

SPECIFICATIONS

Model No NDR 098, Flanged Inlet, DN50 (to BS 4504 part 2:1974)

Model No NDR 097, 2 ½" Screw Thread Inlet to BS21

RIGHT ANGLE LANDING VALVE

SPECIFICATIONS

Model No NDR 106, Flanged Inlet, DN50 (to BS 4504 part 2:1974)

Model No NDR 105, 2 ½" Screw Thread Inlet to BS21

STRAIGHT THROUGH LANDING VALVE (Horizontal Type)

SPECIFICATIONS

Model No NDR 108, Flanged Inlet, DN50 (to BS 4504 part 2:1974)

Model No NDR 107, 2 ½" Screw Thread Inlet to BS21

Landing Valves are used for fighting fire with water and accordingly mounted in fire hydrant system at Internal or External places. The landing valves are sometimes also referred to as internal hydrants because they are usually fitted inside the buildings for wet hydrant sys-tem.

* Kitemark & LPCB approved landing valves available upon request.

* Kitemark & LPCB approved landing valves available upon request.

www.naffco.com 3

Page 4: NAFFCO - fakhribrothers.com · NAFFCO Fire hose rack is located inside buildings at the wet or dry riser outlet. It features a rack in which hangs the lay flat fire hose (30m). An

BIB NOSE TYPE LANDING VALVE

SPECIFICATIONS

Model No NDR 110, Flanged Inlet, DN50 (to BS 4504 part 2:1974)

Model No NDR 109, 2 ½" Screw Thread Inlet to BS21

SPECIFICATIONS

Model No NWR 120, Flanged Inlet, DN50 (to BS 4504 part 2:1974)

Model No NWR 121, 2 ½" Screw Thread Inlet to BS21

Model No NWR 122, Flanged Inlet, DN65 (to BS 4504 part 2:1974)

Optional Storz outlet available upon request

SPECIFICATIONS

Model No NDR 120 1.5" Ø, Female NPT Inlet & Outlet

Model No NDR 121 2.5" Ø, Female NPT Inlet & Outlet

Angle Hose Valve Drain 1.5" & 2.5"

Pressure Rating 300 PSI

Material Cast Brass

Hand Wheel Cast Iron

Finish Standard Rough Brass / Polished Brass

Optional Bright Chrome Plated

PRESSURE REDUCING LANDING VALVE

ANGLE HOSE VALVE

"E" TYPE PRESSURE REGULATING VALVEGENERAL SPECIFICATIONSApplicable Stand-ards

- BS 5041 - 1:1987

Body - Copper Alloy to BS EN 1982

Hand Wheel - Cast Iron to BS EN 1561

Outlet - Female Instantaneous to BS 336 : 2010

Working Pressure - 20 Bar (Max)

Test Pressure - 30 Bar

NAFFCO's Pressure reducing oblique landing valves are suitable for installation on wet risers in buildings for fire fighting purposes, permanently charged with wa-ter from a pressurized supply.These landing valves are pressure reducing type designed to provide a range of outlet pressure (4 bar - 12 bar).The landing valves are classified under high pressure and are suitable for use at nominal inlet pressure upto 20 bar and for working temperature range from 0 °C to 38 °C.

The Angle hose valve is manufactured as per NFPA 13 and most suitable for fire protection service outlet or with a hose rack assembly.

* Kitemark & LPCB approved landing valves available upon request.

www.naffco.com4

Page 5: NAFFCO - fakhribrothers.com · NAFFCO Fire hose rack is located inside buildings at the wet or dry riser outlet. It features a rack in which hangs the lay flat fire hose (30m). An

SPECIFICATIONS

Model No NBI 095, 2 - Way Breeching Inlet (Manufactured & comply to BS 5041 - 3 - 1975)Body Spheroidal Graphite Cast Iron (Ductile Iron) to BS EN 1563:1997Inlet 2 nos. Male instantaneous coupling with NRV to BS 336:2010

Outlet 4" FlangeWorking Pressure 10 Bar

Test Pressure 20 Bar

SPECIFICATIONS

Model No NBI 115 4 - Way Breeching Inlet (Manufactured & comply to BS 5041 - 3 - 1975)Body Spheroidal Graphite Cast Iron (Ductile Iron) to BS EN 1563:1997Inlet 4 no's Male instantaneous coupling with NRV to BS 336:2010

Outlet 6" FlangeWorking Pressure 10 Bar

Test Pressure 20 Bar

SPECIFICATIONS

Model No NSC 95AThread Type Female NPT

Body Cast BrassInlet 2½" Swivel Type

Outlet 4" StraightOptional Cap & Chain / Base plate for Clapper Inlet

SPECIFICATIONS

Model No NWR 103, ¾" Ø InletModel No NWR 104, 1" Ø Inlet

Thread Type Male BSPBody Brass

Test Pressure 350 PSI

BREECHING INLETS

SINGLE CLAPPER TWO WAY INLETS

AIR RELEASE VALVE

NAFFCO Breeching Inlets are suitable for Installation on dry risers only, In a building for fire fighting purposes, fitted with inlet connection at fire brigade access level and outlet connection at specified points, which is nor-mally dry but capable of being charged with water by pumping from the service appliances.

The Breeching inlets are manufactured to com-ply BS 5041 Part - 3: 1975 standard comprising of Male Instantaneous connections complying with BS 336:2010, drain valves PN16 rated and non - return valves.

The clapper design allows for one or both inlets to be pressurized during operation and provide supplemen-tary water supply connection for automatic sprinkler systems as per NFPA13

*Kitemark & LPCB approved Breeching Inlet available upon request.

*Kitemark & LPCB approved Breeching Inlet available upon request.

Air release valves are designed to vent entrained air that collects at high points in the riser.

www.naffco.com 5

Page 6: NAFFCO - fakhribrothers.com · NAFFCO Fire hose rack is located inside buildings at the wet or dry riser outlet. It features a rack in which hangs the lay flat fire hose (30m). An

SPECIFICATIONS

Model No NBC 096, 2 - Way Breeching Inlet Cabinet

Model No NBC 116, 4 - Way Breeching Inlet Cabinet

CabinetElectro - galvanized Steel, Painted with

Electrostatic Powder Coating

Dimensions400 X 600 X 300 - for 2 way ; 600 X 600 X 300 - for 4 way

Glass Wire Mesh Reinforcement

Installation Recess or Surface Mounted

OptionalStainless Steel doors & frames available upon

request

SPECIFICATIONS

Model No NF750

Model No 1½" Ø X 30M Hose / 2½" Ø X 30 Meter

CabinetElectro - galvanized Steel, Painted with

Electrostatic Powder Coating

Dimensions1½" X 30m - 750 X 700 X 200; 2½" X 30m - 850 X 800 X 250

Glass Plain or Wire Mesh Reinforcement

Installation Recess or Surface Mounted

OptionalCabinet material of SS Brush or Mirror Finish

available on request

SPECIFICATIONS

Model No. Type Dimension Body

NHR 250 Swinging Wall Mounted2½" X 30

MeterMild Steel

Painted with Electrostatic

Powder Coating

NHR 250A Swinging Valve Mounted2½" X 30

Meter

NHR 150 Swinging Wall Mounted1½" X 30

Meter

NHR 150A Swinging Valve Mounted1½" X 30

Meter

SPECIFICATIONS

Model No NWR 081

BodyElectro - galvanized Steel, Painted with Elec-

trostatic Powder Coating

Hose 2½" Ø x 30m Hose

Type Swinging

BREECHING INLET CABINET

FIRE HOSE RACK CABINET

FIRE HOSE RACK

FIRE HOSE CRADLE

NAFFCO Breeching Inlet Cabinet is designed to acco-modate 4" & 6" Outlet Breeching inlets. These Cabinets

NAFFCO Fire hose rack cabinet is designed to accomo-date complete assembly of fire hose rack. These Cab-

NAFFCO Fire hose rack is located inside buildings at the wet or dry riser outlet. It features a rack in which hangs the lay flat fire hose (30m). An automatic release

Fire hose is rolled and stored in a swinging cradle designed for easy access. These cradles are Wall mountable and Cabinet mountable.

have either solid or wired glass door and are available in surface or recesses mounting version.

inets have either solid or wired glass door and are available in surface or recesses mounting version.

mechanism allows water to flow through the hose af-ter removal of the hose and nozzle.

*Kitemark & LPCB approved Breeching Inlet available upon request.

*FM approved fire hose rack available upon request.

www.naffco.com6

Page 7: NAFFCO - fakhribrothers.com · NAFFCO Fire hose rack is located inside buildings at the wet or dry riser outlet. It features a rack in which hangs the lay flat fire hose (30m). An

SPECIFICATIONS

Model No NF FB320/WKM

Body Polyamide tip with Aluminum

Alloy inlet

Inlet SizeMale Instantaneous coupling to

BS 336Working Pressure 16 Bar

Flow Control Shut - Jet & Spray

SPECIFICATIONS

Model No. NFL - 13SPQ, 1½" Ø

Flow Rate 490LPM @ 7 Bar

Model No. NFL - 13BPQ, 2½" Ø

Flow Rate 660 - 1020LPM @ 7 Bar

Body Aluminum Alloy, Anodised

Inlet Male Instantaneous to BS 336

Range 40-45M

Optional1. NST threaded Inlet available upon request2. Bronze construction Nozzles available upon request

SPECIFICATIONS

Model No NWR100/NWR 100AL

Body Copper Alloy/Aluminum

Inlet Size 2½" ØFlow Rate 120Gpm@7 Bar

Model No. NWR100A

Body Copper Alloy

Inlet Size 1½ ØFlow Rate 50 Gpm @ 7 Bar

Model No. NWR101P

Body Plastic

Inlet Size 1½" ØRange 15 M

SPECIFICATIONS

Model No NF WC 380A

Flow Rate 380 LPM@7 Bar

Body Cast Bronze with Chrome Finish

Inlet 1½" Ø, NH Female Swivel Inlet

JET & SPRAY NOZZLE

WATER COMBINATION NOZZLES

DIFFUSER NOZZLE

WATER CURTAIN NOZZLE

This durable, plastic nozzle produces a strong, concen-trated jet of water that can fight fires in a most efficient

These kinds of nozzles have been the trend in the Fire Service for several years to utilize greater water flow for initial attack. The most popular water delivery fire hoses

Diffuser nozzle has an adjustable annular orifice which enables the jet of water to be controlled from shut - off

Water Curtain nozzle produces a strong, rain type pat-tern of water that can cool the surrounding areas and structures against flame spread.

*Kitemark & LPCB approved Breeching Inlet available upon request.

way. Yet it is quickly and easily adjustable from a jet to a diffused spray, or a complete shut off.

are 1½" or 2½" with nozzle which flows from 490 to 1,020 LPM. It is also very convenient to use complet-ed shut - off ball valve.

to small jet through to large jet then to spray pattern by turning of the rubber sleeve.

NF FB320/WKM

NF 13SPQ

www.naffco.com 7

Page 8: NAFFCO - fakhribrothers.com · NAFFCO Fire hose rack is located inside buildings at the wet or dry riser outlet. It features a rack in which hangs the lay flat fire hose (30m). An

Dubai, United Arab EmiratesEmail: [email protected]

NAFFCO FZCOWORLD HEADQUARTERS

In line with NAFFCO policy for continuous product development,NAFFCO has the right to change specifications without prior notice.

QUALITY SYSTEMNAFFCO FZCO is certified to ISO 9001 Quality system by UL DQS Inc, Loss Prevention Certification Board UK & Bureau Veritas. Our manufacturing processes are based on a quality system that ensures the use of raw material conforming to relevant International Standards. Our in process production is monitored by work standards & quality plans conforming to relevant International Standards enabling

us to deliver quality products.

APPROVALSNAFFCO has been maintaining ISO 9001 Quality Management system certified by UL, LPCB & BV. Further we have achieved ISO14001 for Environmental Management & BS OHSAS 18001 for occupational safety by UL management systems. We have also achieved product certifications from UL, FM, LPCB, BSI, CE & SAI Global on wide range of products which include Fire Extinguishers, Fire Hose Reels, Centrifugal Fire Pumps, Diesel Engine for driving Fire Pumps, Fire doors and Fire Fighting Equipment. UL has authorized NAFFCO as service center for certifying signal and fire alarm equipment.

ENGINEERING CAPABILITIESNAFFCO is backed by a team of professionals who are well qualified and specialized in their respective field viz. - Design, Development, Production and Project Implementation. Our investment in applied

research and development program concentrates on innovations which meets customer needs.

PRODUCT RANGE

Your most reliable partner in supplyingstate-of-the-art products and providinghigh quality services based onInternational Standards

CAT

.NO.NF/VRE/10/13

MANAGEMENTSYSTEMS

ASSESSED TO ISO 9001:2008