24
N5412A SAS Electrical Performance Validation and Compliance Test Software

N5412A SAS Electrical Performance Validation and Compliance Test Software

Embed Size (px)

Citation preview

Page 1: N5412A SAS Electrical Performance Validation and Compliance Test Software

N5412A SAS Electrical Performance Validation and Compliance Test Software

Page 2: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 2

Serial Attached SCSISmall Computer Serial Interconnect (SCSI) just got a whole lot smaller, faster & more versatile.

•Performance – Gen 1 at 300MBytes/sec per lane

•Scalability – Multi-port, long cables, up to 1.2GBytes/sec

•Reliability and Availability – Secondary failover, P2P

•Flexibility – Supports SAS & SATA drives and SCSI SW

Page 3: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 3

HDD/ODD

SubsystemsComponentsStorage

Interconnect

Heterogeneous Data SolutionsHP Server/Brocade/EMC Storage

Host Bus AdaptersSemiconductors

System Integrators

Heterogeneous Data SolutionsHP Server/Brocade/EMC Storage

Motherboards

SATA Storage Market Segments

Allion ComputerFaraday

Technology Corp.Genesys Logic

AmericaJmicron

Technology Corp.LSI Logic

LyCOM TechnologyNetCell

CorporationPanasonic

SILICONSTORSUNEXT Design

STMicroelectronics

MarvellSilicon Image

ACARD Technology Corp.

Agere SystemsFujitsu Computer

ProductsHitachi GSTSamsungSeagate

STMicroelectronicsToshiba

Western DigitalLite On

TechnologiesIomega Corp.Media Tek Inc.

Philips

AdaptecAddonics

TechnologyAMCC

Jmicron TechnologyLSI LogicNetcell

TechnologyPacific Digital

Corp.3Ware

IntelDellHP

Scientific AtlantaATI Technologies

Page 4: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 4

SAS Storage Market Segments

HDD

SubsystemsComponents Storage Interconnect

Heterogeneous Data SolutionsHP Server/Brocade/EMC Storage

HBA/RAID/Expander

Semiconductors

System Integrators

Heterogeneous Data SolutionsHP Server/Brocade/EMC Storage

Server / PC MB

Page 5: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 5

HDD Interfaces for Multi-user Market

0

5,000

10,000

15,000

20,000

25,000

30,000

35,000

40,000

2004 2005 2006 2007 2008

Th

ou

san

ds o

f U

nit

s

PATA/ SATA

FC-AL

SAS

Parallel SCSI

(Gartner Ref. 3)

Page 6: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 6

Market Trends

We’re primed to meet this major transition from existing parallel to serial!

Source: http://www.scsita.org

Page 7: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 7

Market Trends

Tek

Compliance

Test

Tek’s solution is based on a 2003 version of the standard and offers no method of connectivity to the

DUT!

Page 8: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 8

Market Trends

Tek

Compliance

Test

Agilent

Compliance

Test

Agilent’s solution is based on the 2005 version of the standard and directly leverages the UNH-IOL SAS

test suite!!!

Page 9: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 9

N5412A is modeled after the industry standard

•UNH-IOL SAS Test Suite is the industry standard.

•Interoperability testing starts at the PHY layer.

•Our solution is complete:

• Minimum of a 10GHz real-time scope

• Reference test loads and connectivity as per the specification

• Provide common tests and algorithms to the UNH-IOL solution

Page 10: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 10

Product DefinitionThe N5412A SAS Electrical Compliance Test application:

•Supports Gen 1(1.5Gbps) and Gen 2(3Gbps) data rates

•Supports the IT, CT Transmit (TX) interfaces and the IR, CR Far-end Transmit (TX) interfaces

•Provides automated 81134A stimulus for OOB signal tests

•REQUIRES that the PHY (DUT) be able to generate CJTPAT, the Compliance Jitter Test Pattern, for testing

•Additionally, Agilent will provide the most common x2 internal drive/host test fixture (Zero-Length Test Load), Transient Test Fixture and Transmitter Compliance Transfer Function (TCTF) for the IT compliance point testing.

Page 11: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 11

N5412A SAS Electrical Compliance Test CoverageThe N5412A SAS Electrical Compliance Tests:•Maximum/Minimum Rising Time.

•Maximum/Minimum Falling Time.

•Eye Inner amplitude(or minimum eye opening).

•Max peak to peak output amplitude.

•Maximum Noise during OOB idle time.

•Maximum transmitter device off voltage.

•Maximum transmitter output imbalance.

•OOB offset delta.

•OOB common-mode delta.

•Maximum jitter.

•Maximum skew.

•Maximum voltage at non-operational.

•Minimum OOB burst amplitude.

•Maximum Transients.

•Bit Rate.

Page 12: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 12

SAS Compliance Points

Page 13: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 13

SAS Interface Connector Descriptions

Type       Section    

Ref. pg.   

Connector ref.    Interface Name      

Internal   5.2.3.2.1  

pg. 98     

SFF-8482         

SAS x2 Internal Plug Connector    

Internal   5.2.3.2.2  

pg. 98     

SFF-8482         

SAS x2 Internal Cable Receptacle    

Internal   5.2.3.2.3  

pg. 99     

SFF-8482         

SAS x2 Internal Backplane Receptacle  

                   

Int. Wide  5.2.3.4.2  

pg. 108    

SFF-8484         

SAS x4 Internal Wide Cable Receptacle Connector

Int. Wide  5.2.3.4.3  

pg. 109    

SFF-8484         

SAS x4 Internal Wide Plug Connector    

Int. Wide  5.2.3.4.5  

pg. 111    

SFF-8087/86      

SAS x4 Internal Compact Wide Plug Connector  

Int. Wide  5.2.3.4.6  

pg. 112    

SFF-8087/86      

SAS x4 Internal Compact Wide Receptacle Connector

                   

External   5.2.3.3.2  

pg. 101    

SFF-8470         

SAS x4 External Cable Plug Connector  

External   5.2.3.3.3  

pg. 101    

SFF-8470         

SAS x4 External Receptacle Connector  

External   5.2.3.3.5  

pg. 103    

SFF-8088/86      

SAS x4 External Compact Cable Plug Connector  

External   5.2.3.3.6  

pg. 104    

SFF-8088/86      

SAS x4 External Compact Receptacle Connector

Page 14: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 14

SFF-8482 SAS x2 Internal Connectors

SFF-8482 Plug (Drive/Backpl

ane / IT Interface)

SFF-8482 Cable

Receptacle / IR

Interface

Page 15: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 15

SFF-8484 SAS x4 Internal Connectors

SFF-8484 Cable

Receptacle / IR

Interface

SFF-8484 Plug (HBA

/ IT Interface)

Page 16: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 16

SFF-8470 SAS x4 External Connectors (

SFF-8470 External

Receptacle / CT

Interface

SFF-8470 Plug (Inter-

Enclosure / CR Interface)

Page 17: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 17

Simplistic Single-Port Server ConfigurationA SATA host is analogous to a SAS initiator device; a SATA

device is analogous to a SAS target device. Compliance is defined at the connectors for both buses.

Connector Topology

SATA x1 connector receptacle

SAS Host: SFF-8482 receptacle

SAS Device: SFF-8482 receptacle

Page 18: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 18

Simplistic 4-Port Server ConfigurationA 4-port SAS controller (host bus adapter, usually PCI-X or

PCIe to SAS) will have an internal x4 connector, and will fan out to four individual x1 connectors on SATA or SAS drives. In this case, only the primary port will be used and the secondary port remains unused.

Connector Topology

SAS Host: SFF-8484 receptacle

SAS Device: SFF-8482 receptacle

Page 19: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 19

SAS Test Fixture Requirements

In general, SAS compliance testing will require:

•An adapter from the SAS connector to SMA

•A TCTF (omitted for ZLTL tests)

•A termination network (provided by scope 50-ohm terminations OR Transient Test Circuit)

Page 20: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 20

SAS x1 Internal (IT) Zero-Length Test Load

Available From CRUZ Systems (Worldwide Distribution)Internet: www.cruzsystems.com

Near End Test Fixture (Drive, HBA)

H303000202 iSATA Test Fixture (Drive/Host)

Far End Test Fixture (cable)

H303000102 iSATA Text Fixture (Cable)

Used for physical

layer electrical & impedance

testsUsed for

cable impedance

tests

Page 21: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 21

SAS x2 Internal (IT) Zero-Length Test Load & TCTF

Available now! N5421A SFF-8482 Test Fixture $3000 US DDP

Page 22: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 22

SAS x4 External (CT) Zero-Length Test Load

Available From Gore as IBNTST4X for $3800

Page 23: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 23

SAS x4 External (CT) TCTF

Available From Molex upon request

Page 24: N5412A SAS Electrical Performance Validation and Compliance Test Software

SAS Compliance Test Presentation Page 24

Complete SAS UNH-IOL TEST COVERAGE !

Test Parameter  UNH-IOL AgilentOOB Signaling TestsTX Maximum Transients Y Y

RX Maximum Transients Y Y

TX OOB Offset Delta Y Y

TX OOB Common Mode Delta Y Y

TX Minimum OOB ALIGN Burst Amplitude Y Y

TX Maximum Noise During OOB Idle Y Y

COMINIT (Device) Y Y

COMRESET (Host) Y Y

COMSAS (Host/Device) Y Y

Transmitted Signal RequirementsMaximum Skew Y Y

TX Maximum Device Off Voltage Y Y

Maximum Rise/Fall Time Y Y

Minimum Rise/Fall Time Y Y

Maximum TX Output Imbalance Y Y

Maximum J itter Y Y

TX Maximum Non- operational Voltage Y Y

Maximum Peak- Peak Voltage Y Y

Minimum Eye Opening Y YBit Rate Y Y