Suitable for installation mostly for power supplystations, in indoors and in cable ducts, outdoors,underground, and in water as well as for installationon cable trays for industries, switch-boards and power stations. Due to the good laying characteristics, thiscan also be laid easily in difficult line guideways.See DIN VDE 0298 part 1 .To avoid the influence of the outer interferences, anadherent semi conductive layer is extruded betweenthe conductor and the VPE insulation and also aconcentric copper conductor wich guarantees thefield-limitation and the resistance to the partialdischarges 2 pC by a measuring volt of 2 U .
To guarantee an optimum on operating reliabilitythe extruded semi-conductive layer is spliced withthe insulation for long duration.For this reason we reccomend a peeling tool for installation.
U /U 6/10 kV, 12/20 kV, 18/30 kV
Temperature Range:
Test voltages:
Min. Bending Radius:
Nominal voltages:
15 x d
Conductor:
Insulation:
Installation notes:
Operatingtemperature:
Short circuittemperature:
during installation up to - 5°C
max. + 90°C
250°C
(short circuit duration up to 5 sec.)
Operating voltages: for 6/10 kV = max. 12 kV 12/20 kV = max. 24 kV 18/30 kV = max. 36 kV
for 6/10 kV = 15 kV 12/20 kV = 30 kV 18/30 kV = 45 kV
circular bare cu-conductor of strandedwires to HD 383
core insulation of cross-linkedpolyethylene (XLPE), PE-compoundDIX8 to HD 620.1
Screen:
Outer jacket:
screen of copper wires and one or twocopper tape(s) applied helically.
PVC-outer jacket black, compound DMV 6to HD 620.1, jacket colour red.
Outer min. - max.mm mm
No. of coresx cross sectionn x mm
Item no. AWGno.*)
Weightca.kg/km
Insulationthickness mm
* For cables laying in earth a screen-cross section of 16 mm is permitted.
Copper weightca.kg/km
PVC-jacketthickness mm
20001064
20001065
20001066
20001067
20001068
200010691
20001069200010701
20001070
200010711
20001071
20001072
20001073
20001074
20002064
20002065
20002066
20002067
20002068
200020691
20002069
200020701
20002070
200020711
20002071
2000207220002073
20002074
1x35 rm/16
1x50 rm/16
1x70 rm/16
1x95 rm/16
1x120 rm/16
1x150 rm/16*
1x150 rm/251x185 rm/16*
1x185 rm/25
1x240 rm/16*
1x240 rm/25
1x300 rm/25
1x400 rm/35
1x500 rm/35
1x35 rm/16
1x50 rm/16
1x70 rm/16
1x95 rm/16
1x120 rm/16
1x150 rm/16*
1x150 rm/25
1x185 rm/16*
1x185 rm/25
1x240 rm/16*
1x240 rm/25
1x300 rm/251x400 rm/35
1x500 rm/35
3.4
3.4
3.4
3.4
3.4
3.4
3.43.4
3.4
3.4
3.4
3.4
3.4
3.4
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.55.5
5.5
2.5
2.5
2.5
2.5
2.5
2.5
2.52.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.52.5
2.5
23
24
26
27
29
30
3032
32
34
34
36
40
43
27
28
30
31
33
34
34
36
36
39
39
4144
47
28
29
31
32
34
35
3537
37
39
39
41
45
48
32
33
35
36
38
39
39
41
41
44
44
4649
52
518
662
860
1098
1340
1622
17251958
2059
2486
2587
3163
4234
5194
518
662
854
1094
1334
1622
1723
1958
2059
2486
2587
31634234
5194
905
1080
1310
1580
1860
2040
22102450
2580
3000
3130
3780
4670
5750
1110
1250
1510
1780
2070
2310
2420
2650
2810
3260
3360
40204930
6050
2
1
2/0
3/0
4/0
250 MCM
250 MCM 350 MCM
350 MCM
450 MCM
450 MCM
550 MCM
750 MCM
1000 MCM
2
1
2/0
3/0
4/0
250 MCM
250 MCM
350 MCM
350 MCM
450 MCM
450 MCM
550 MCM 750 MCM
1000 MCM
6/10 kV
12/20 kV
18/30 kV
Outer min. - max.mm mm
No. of coresx cross sectionn x mm
Item no. AWGno.*)
Weightca.kg/km
Insulationthickness mm
Copper weightca.kg/km
PVC-jacketthickness mm
20003065
20003066
20003067
20003068
20003069
20003070
2000307120003072
20003073
20003074
1x50 rm/16
1x70 rm/16
1x95 rm/16
1x120 rm/16
1x150 rm/25
1x185 rm/25
1x240 rm/251x300 rm/25
1x400 rm/35
1x500 rm/35
8.0
8.0
8.0
8.0
8.0
8.0
8.08.0
8.0
8.0
2.5
2.5
2.5
2.5
2.5
2.5
2.52.5
2.5
2.5
33
35
36
38
39
41
4346
49
52
38
40
41
43
44
46
4851
54
57
662
854
1094
1334
1723
2059
25873163
4234
5194
1480
1730
2060
2330
2720
3100
37304000
5330
6480
1
2/0
3/0
4/0
300 MCM
350 MCM
500 MCM 600 MCM
750 MCM
1000 MCM
N2XSY 6/10 kV, 12/20 kV, 18/30 kVPVC- jacket
CE
MEDIUM VOLTAGE CABLES
Other constructions and sizes are available on request.
Cable Structure: Technical data:
Application
BAGNOLO IN PIANO (RE) - ITALY TEL : +39 0522 958938 - FAX : +39 0522 951882 - www.elettrotekkabel.com