137
IBM System Storage N series Data ONTAP 7.3 Software Setup Guide GC27-2206-07 NA 210-05189_A0

N Series Data ONTAP Software Setup Guide

Embed Size (px)

Citation preview

Page 1: N Series Data ONTAP Software Setup Guide

IBM System Storage N seriesData ONTAP 7.3 Software Setup Guide

GC27-2206-07NA 210-05189_A0

Page 2: N Series Data ONTAP Software Setup Guide
Page 3: N Series Data ONTAP Software Setup Guide

Contents

Copyright information ................................................................................. 7Trademark information ............................................................................... 9About this guide .......................................................................................... 11

Audience .................................................................................................................... 11

Supported features ..................................................................................................... 12

Getting information, help, and services .................................................................... 12

Before you call .............................................................................................. 13

Using the documentation ............................................................................... 13

Web sites ....................................................................................................... 13

Accessing online technical support ............................................................... 13

Hardware service and support ....................................................................... 14

Supported servers and operating systems ...................................................... 14

Firmware updates .......................................................................................... 14

Accessing Data ONTAP man pages .......................................................................... 14

Terminology .............................................................................................................. 15

Where to enter commands ......................................................................................... 17

Keyboard and formatting conventions ...................................................................... 17

Special messages ....................................................................................................... 18

How to send your comments ..................................................................................... 19

Overview of the software setup process ................................................... 21Software setup stages ................................................................................................ 21

Default storage system configuration ........................................................................ 22

About the setup process ............................................................................................. 23

Setup methods ........................................................................................................... 23

Prerequisites to initial configuration ........................................................ 25Requirements for the administration host ................................................................. 25

Active/active configuration requirements ................................................................. 26

Requirements for Windows domains ........................................................................ 26

Assigning domain administrator privileges ................................................... 26

Creating a storage system domain account before setting up CIFS .............. 27

Requirements for Active Directory authentication ................................................... 28

DNS requirements for Active Directory ....................................................... 28

Table of Contents | 3

Page 4: N Series Data ONTAP Software Setup Guide

Network infrastructure requirements for Active Directory ........................... 29

Time services requirements ....................................................................................... 29

Switch configuration requirements for vifs ............................................................... 30

DHCP requirements for remote access ..................................................................... 30

Requirements for creating array LUNs for gateways ................................................ 31

Gateway licensing requirements ............................................................................... 31

Configuration information you need to gather ........................................ 33Configuration worksheet ........................................................................................... 33

Required storage system information ........................................................................ 38

Network information ................................................................................................. 39

Virtual network interface information ....................................................................... 43

HTTP information ..................................................................................................... 45

DNS services information ......................................................................................... 46

NIS services information ........................................................................................... 46

CIFS protocol information ........................................................................................ 47

Required IBM customer information ........................................................................ 52

Baseboard Management Controller information ....................................................... 53

Remote LAN Module information ............................................................................ 54

Service processor information ................................................................................... 55

Shelf Alternate Control Path Management information ........................................... 56

The ACP subnet ............................................................................................ 57

Setting up your storage system for using native disk shelves ................. 59Responding to setup command prompts ................................................................... 60

Responding to FilerView Setup Wizard prompts ..................................................... 64

Responding to cifs setup prompts ............................................................................. 66

Responding to rlm setup prompts .............................................................................. 68

Responding to sp setup prompts ................................................................................ 70

Additional steps required to set up gateways using native disk shelves and third-

party storage ........................................................................................................ 72

Setting up your system for using only third-party storage ..................... 73Before starting setup for using third-party storage .................................................... 73

Providing array LUN ownership and system ID for gateways ................................. 73

Installing Data ONTAP software on a gateway ....................................... 77Data ONTAP installation stages ............................................................................... 77

How you install licenses on a storage system ........................................................... 78

Installing licenses on a single system ............................................................ 78

4 | Data ONTAP 7.3 Software Setup Guide

Page 5: N Series Data ONTAP Software Setup Guide

Installing licenses on an active/active configuration ..................................... 79

Obtaining Data ONTAP software images ................................................................. 79

Obtaining images for HTTP servers .............................................................. 80

Obtaining images for UNIX clients .............................................................. 81

Obtaining images for Windows clients ......................................................... 83

Installing Data ONTAP software images .................................................................. 85

Installing software images from the /etc/software directory ......................... 85

Installing software images from an HTTP server ......................................... 88

Managing files in the /etc/software directory ............................................................ 91

Verifying software setup ............................................................................ 93Verifying network connectivity ................................................................................ 93

Troubleshooting connections to new network interfaces .............................. 94

Verifying host-name resolution ................................................................................. 94

Verifying that the storage system is available ........................................................... 96

Verifying licensing .................................................................................................... 97

Preparing NFS clients to access the storage system .................................................. 97

Exporting file systems to NFS clients ........................................................... 97

Preparing CIFS clients to access the storage system ................................................. 99

Creating a storage system DNS "A" record for CIFS client access .............. 99

Verifying the configuration for active/active storage systems .................................. 99

Verifying BMC connections ................................................................................... 100

Verifying RLM connections .................................................................................... 101

Verifying the existence of two paths to an array LUN in a gateway ...................... 103

Verifying the existence of two paths with the storage show disk

command ............................................................................................... 103

Verifying path failover for array LUNs in a gateway ............................................. 104

Verifying path failover for array LUNs in a stand-alone system ................ 104

Verifying path failover for array LUNs in an active/active configuration .. 105

Where to go from here ............................................................................. 107Time zones ................................................................................................. 109

Time zones by geographical region ........................................................................ 110

GMT offset and miscellaneous time zones ............................................................. 115

Supported languages ................................................................................ 119Specifying the language code .................................................................................. 119

Language choices .................................................................................................... 119

Country codes ........................................................................................... 121

Table of Contents | 5

Page 6: N Series Data ONTAP Software Setup Guide

What to do if the system does not boot when powered on .................... 131Troubleshooting if the N6000 series, N3300, N3400, or N3600 system does not

boot .................................................................................................................... 131

Index ........................................................................................................... 133

6 | Data ONTAP 7.3 Software Setup Guide

Page 7: N Series Data ONTAP Software Setup Guide

Copyright and trademark information | 7

Copyright and trademark information

Copyright information

Copyright ©1994 - 2011 NetApp, Inc. All rights reserved. Printed in the U.S.A.

Portions copyright © 2011 IBM Corporation. All rights reserved.

US Government Users Restricted Rights - Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.

No part of this document covered by copyright may be reproduced in any form or by any means—graphic,electronic, or mechanical, including photocopying, recording, taping, or storage in an electronic retrievalsystem—without prior written permission of the copyright owner.

References in this documentation to IBM products, programs, or services do not imply that IBM intendsto make these available in all countries in which IBM operates. Any reference to an IBM product,program, or service is not intended to state or imply that only IBM’s product, program, or service maybe used. Any functionally equivalent product, program, or service that does not infringe any of IBM’sor NetApp’s intellectual property rights may be used instead of the IBM or NetApp product, program,or service. Evaluation and verification of operation in conjunction with other products, except thoseexpressly designated by IBM and NetApp, are the user's responsibility.

No part of this document covered by copyright may be reproduced in any form or by any means—graphic,electronic, or mechanical, including photocopying, recording, taping, or storage in an electronic retrievalsystem—without prior written permission of the copyright owner.

Software derived from copyrighted NetApp material is subject to the following license and disclaimer:

THIS SOFTWARE IS PROVIDED BY NETAPP "AS IS" AND WITHOUT ANY EXPRESS ORIMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIESOF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBYDISCLAIMED. IN NO EVENT SHALL NETAPP BE LIABLE FOR ANY DIRECT, INDIRECT,INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUTNOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANYTHEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OFTHIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

NetApp reserves the right to change any products described herein at any time, and without notice.NetApp assumes no responsibility or liability arising from the use of products described herein, exceptas expressly agreed to in writing by NetApp. The use or purchase of this product does not convey alicense under any patent rights, trademark rights, or any other intellectual property rights of NetApp.

The product described in this manual may be protected by one or more U.S.A. patents, foreign patents,or pending applications.

RESTRICTED RIGHTS LEGEND: Use, duplication, or disclosure by the government is subject torestrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Softwareclause at DFARS 252.277-7103 (October 1988) and FAR 52-227-19 (June 1987).

Page 8: N Series Data ONTAP Software Setup Guide

8 | Copyright and trademark information

Trademark information

IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both. A complete and current list of other IBM trademarks is available on the Web at http://www.ibm.com/legal/copytrade.shtml

Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both.

Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both.

UNIX is a registered trademark of The Open Group in the United States and other countries.

NetApp, the NetApp logo, Network Appliance, the Network Appliance logo, Akorri, ApplianceWatch, ASUP, AutoSupport, BalancePoint, BalancePoint Predictor, Bycast, Campaign Express, ComplianceClock, Cryptainer, CryptoShred, Data ONTAP, DataFabric, DataFort, Decru, Decru DataFort, FAServer, FilerView, FlexCache, FlexClone, FlexScale, FlexShare, FlexSuite, FlexVol, FPolicy, GetSuccessful, gFiler, Go further, faster, Imagine Virtually Anything, Lifetime Key Management, LockVault, Manage ONTAP, MetroCluster, MultiStore, NearStore, NetCache, NOW (NetApp on the Web), ONTAPI, OpenKey, RAID-DP, ReplicatorX, SANscreen, SecureAdmin, SecureShare, Select, Shadow Tape, Simulate ONTAP, SnapCopy, SnapDirector, SnapDrive, SnapFilter, SnapLock, SnapManager, SnapMigrator, SnapMirror, SnapMover, SnapRestore, Snapshot, SnapSuite, SnapValidator, SnapVault, StorageGRID, StoreVault, the StoreVault logo, SyncMirror, Tech OnTap, The evolution of storage, Topio, vFiler, VFM, Virtual File Manager, VPolicy, WAFL, and Web Filer are trademarks or registered trademarks of NetApp, Inc. in the United States, other countries, or both.

All other brands or products are trademarks or registered trademarks of their respective holders and should be treated as such.

NetApp is a licensee of the CompactFlash and CF Logo trademarks.

NetApp NetCache is certified RealSystem compatible.

Page 9: N Series Data ONTAP Software Setup Guide

Notices | 9

Notices

This information was developed for products and services offered in the U.S.A.

IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe on any IBM intellectual property right may be used instead. However, it is the user’s responsibility to evaluate and verify the operation of any non-IBM product, program, or service.

IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing to:

IBM Director of Licensing IBM Corporation North Castle Drive Armonk, N.Y. 10504-1785 U.S.A.

For additional information, visit the web at: http://www.ibm.com/ibm/licensing/contact/

The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law:

INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.

Any references in this information to non-IBM web sites are provided for convenience only and do not in any manner serve as an endorsement of those web sites. The materials at those web sites are not part of the materials for this IBM product and use of those web sites is at your own risk.

Page 10: N Series Data ONTAP Software Setup Guide

10 | Notices

IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.

Any performance data contained herein was determined in a controlled environment. Therefore, the results obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurement may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment.

Information concerning non-IBM products was obtained from the suppliers of those products, their published announcements or other publicly available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products.

If you are viewing this information in softcopy, the photographs and color illustrations may not appear.

Page 11: N Series Data ONTAP Software Setup Guide

About this guide

You can use your product more effectively when you understand this document's intended audienceand the conventions that this document uses to present information.

This document describes how to set up and configure storage systems that run Data ONTAPsoftware. It covers all supported storage system models.

Note: In this document, the term gateway describes IBM N series storage systems that have beenordered with gateway functionality. Gateways support various types of storage, and they are usedwith third-party disk storage systems—for example, disk storage systems from IBM, HP®, HitachiData Systems®, and EMC®. In this case, disk storage for customer data and the RAID controllerfunctionality is provided by the back-end disk storage system. A gateway might also be used withdisk storage expansion units specifically designed for the IBM N series models.

The term filer describes IBM N series storage systems that either contain internal disk storage orattach to disk storage expansion units specifically designed for the IBM N series storage systems.Filer storage systems do not support using third-party disk storage systems.

Next topics

Audience on page 11

Supported features on page 12

Getting information, help, and services on page 12

Accessing Data ONTAP man pages on page 14

Terminology on page 15

Where to enter commands on page 17

Keyboard and formatting conventions on page 17

Special messages on page 18

How to send your comments on page 19

AudienceThis document is written with certain assumptions about your technical knowledge and experience.

This document is for system administrators who are familiar with operating systems that run on thestorage system's clients.

It also assumes that you are familiar with how to configure the storage system and how Network FileSystem (NFS), Common Internet File System (CIFS), and Hypertext Transport Protocol (HTTP) areused for file sharing or transfers. This guide doesn't cover basic system or network administrationtopics, such as IP addressing, routing, and network topology.

About this guide | 11

Page 12: N Series Data ONTAP Software Setup Guide

If you are installing new storage systems, this is the correct guide for you. If you are unsure, use thefollowing table to decide which guide to read.

If you are ... Read ...

Configuring a new storage system This guide

If you are configuring a new gateway, see alsoyour Gateway Installation Requirements andReference Guide.

If you are configuring a new storage system inan FC or iSCSI environment, see also your DataONTAP Block Access Management Guide foriSCSI and FC.

Upgrading an existing storage system to thisversion of the Data ONTAP software

The Data ONTAP Upgrade Guide

Converting existing storage systems to an active/active configuration

The Data ONTAP Active/Active ConfigurationGuide

Supported features

IBM® System Storage™ N series storage systems are driven by NetApp® Data ONTAP® software.Some features described in the product software documentation are neither offered nor supported byIBM. Please contact your local IBM representative or reseller for further details. Information aboutsupported features can also be found at the following Web site:

www.ibm.com/storage/support/nas/

A listing of currently available N series products and features can be found at the following Web site:

www.ibm.com/storage/nas/

Getting information, help, and services

If you need help, service, or technical assistance or just want more information about IBM products,you will find a wide variety of sources available from IBM to assist you. This section containsinformation about where to go for additional information about IBM and IBM products, what to do ifyou experience a problem with your IBM N series product, and whom to call for service, if it isnecessary.

Next topics

Before you call on page 13

Using the documentation on page 13

12 | Data ONTAP 7.3 Software Setup Guide

Page 13: N Series Data ONTAP Software Setup Guide

Web sites on page 13

Accessing online technical support on page 13

Hardware service and support on page 14

Supported servers and operating systems on page 14

Firmware updates on page 14

Before you call

Before you call, make sure that you have taken these steps to try to solve the problem yourself:

• Check all cables to make sure that they are connected properly.• Check the power switches to make sure that the system is turned on.• Use the troubleshooting information in your system documentation and use the diagnostic tools

that come with your system.

Using the documentation

Information about N series hardware products is available in printed documents and a documentationCD that comes with your system. The same documentation is available as PDF files on the IBM NASsupport Web site:

www.ibm.com/storage/support/nas/

Data ONTAP software publications are available as PDF files on the IBM NAS support Web site:

www.ibm.com/storage/support/nas/

Web sites

IBM maintains pages on the World Wide Web where you can get the latest technical information anddownload device drivers and updates.

• For NAS product information, go to the following Web site:www.ibm.com/storage/nas/

• For NAS support information, go to the following Web site:www.ibm.com/storage/support/nas/

• For AutoSupport information, go to the following Web site:www.ibm.com/storage/support/nas/

• For the latest version of publications, go to the following Web site:www.ibm.com/storage/support/nas/

Accessing online technical support

For online Technical Support for your IBM N series product, visit the following Web site:

www.ibm.com/storage/support/nas/

About this guide | 13

Page 14: N Series Data ONTAP Software Setup Guide

Hardware service and support

You can receive hardware service through IBM Integrated Technology Services. Visit the followingWeb site for support telephone numbers:

www.ibm.com/planetwide/

Supported servers and operating systems

IBM N series products attach to many servers and many operating systems. To determine the latestsupported attachments, follow the link to the Interoperability Matrices from the following Web site:

www.ibm.com/systems/storage/network/interophome.html

Firmware updates

As with all devices, it is recommended that you run the latest level of firmware, which can bedownloaded by visiting the following Web site:

www.ibm.com/storage/support/nas/

Verify that the latest level of firmware is installed on your machine before contacting IBM fortechnical support. See the Data ONTAP Upgrade Guide for your version of Data ONTAP for moreinformation on updating firmware.

Accessing Data ONTAP man pagesYou can use the Data ONTAP manual (man) pages to access technical information.

About this task

Data ONTAP manual pages are available for the following types of information. They are groupedinto sections according to standard UNIX naming conventions.

Types of information Man page section

Commands 1

Special files 4

File formats and conventions 5

System management and services 8

Step

1. View man pages in the following ways:

14 | Data ONTAP 7.3 Software Setup Guide

Page 15: N Series Data ONTAP Software Setup Guide

• Enter the following command at the storage system command line:

man command_or_file_name

• Click the manual pages button on the main Data ONTAP navigational page in the FilerViewuser interface.

• Use the Commands: Manual Page Reference, Volumes 1 and 2

Note: All Data ONTAP man pages are stored on the storage system in files whose names areprefixed with the string "na_" to distinguish them from client man pages. The prefixed namesare used to distinguish storage system man pages from other man pages and sometimes appearin the NAME field of the man page, but the prefixes are not part of the command, file, orservices.

TerminologyTo understand the concepts in this document, you might need to know how certain terms are used.

Storage terms

array LUN The storage that third-party storage arrays provide to storage systems running DataONTAP software. One array LUN is the equivalent of one disk on a native diskshelf.

LUN (logicalunit number)

A logical unit of storage identified by a number.

native disk A disk that is sold as local storage for storage systems that run Data ONTAPsoftware.

native diskshelf

A disk shelf that is sold as local storage for storage systems that run Data ONTAPsoftware.

storagecontroller

The component of a storage system that runs the Data ONTAP operating systemand controls its disk subsystem. Storage controllers are also sometimes calledcontrollers, storage appliances, appliances, storage engines, heads, CPU modules,or controller modules.

storage system The hardware device running Data ONTAP that receives data from and sends datato native disk shelves, third-party storage, or both. Storage systems that run DataONTAP are sometimes referred to as filers, appliances, storage appliances,gateways, or systems.

Note: The term gateway describes IBM N series storage systems that have beenordered with gateway functionality. Gateways support various types of storage,and they are used with third-party disk storage systems—for example, diskstorage systems from IBM, HP®, Hitachi Data Systems®, and EMC®. In thiscase, disk storage for customer data and the RAID controller functionality isprovided by the back-end disk storage system. A gateway might also be used

About this guide | 15

Page 16: N Series Data ONTAP Software Setup Guide

with disk storage expansion units specifically designed for the IBM N seriesmodels.

The term filer describes IBM N series storage systems that either containinternal disk storage or attach to disk storage expansion units specificallydesigned for the IBM N series storage systems. Filer storage systems do notsupport using third-party disk storage systems.

third-partystorage

The back-end storage arrays, such as IBM, Hitachi Data Systems, and HP, thatprovide storage for storage systems running Data ONTAP.

Cluster and high-availability terms

active/activeconfiguration

• In the Data ONTAP 7.2 and 7.3 release families, a pair of storage systems orgateways (sometimes called nodes) configured to serve data for each other ifone of the two systems stops functioning. Also sometimes referred to asactive/active pairs.

• In the Data ONTAP 8.x release family, this functionality is referred to as ahigh-availability (HA) configuration or an HA pair.

• In the Data ONTAP 7.1 release family, this functionality is referred to as acluster.

cluster • In Data ONTAP 8.x, a group of connected nodes (storage systems) that sharea global namespace and that you can manage as a single virtual server ormultiple virtual servers, providing performance, reliability, and scalabilitybenefits.

• In the Data ONTAP 7.1 release family, a pair of storage systems (sometimescalled nodes) configured to serve data for each other if one of the two systemsstops functioning.

• In the Data ONTAP 7.3 and 7.2 release families, this functionality is referredto as an active/active configuration.

• For some storage array vendors, cluster refers to the hardware component onwhich host adapters and ports are located. Some storage array vendors refer tothis component as a controller.

HA (highavailability)

• In Data ONTAP 8.x, the recovery capability provided by a pair of nodes(storage systems), called an HA pair, that are configured to serve data foreach other if one of the two nodes stops functioning.

• In the Data ONTAP 7.3 and 7.2 release families, this functionality is referredto as an active/active configuration.

HA pair • In Data ONTAP 8.x, a pair of nodes (storage systems) configured to servedata for each other if one of the two nodes stops functioning.

16 | Data ONTAP 7.3 Software Setup Guide

Page 17: N Series Data ONTAP Software Setup Guide

• In the Data ONTAP 7.3 and 7.2 release families, this functionality is referredto as an active/active configuration.

Where to enter commandsYou can use your product more effectively when you understand how this document uses commandconventions to present information.

You can perform common administrator tasks in one or more of the following ways:

• You can enter commands either at the system console or from any client computer that can obtainaccess to the storage system using a Telnet or Secure Shell (SSH) session.In examples that illustrate command execution, the command syntax and output shown mightdiffer from what you enter or see displayed, depending on your version of the operating system.

• You can use the FilerView graphical user interface.For information about accessing your system with FilerView, see the Data ONTAP SystemAdministration Guide.

• You can enter Windows, ESX, HP-UX, AIX, Linux, and Solaris commands at the applicableclient console.In examples that illustrate command execution, the command syntax and output shown mightdiffer from what you enter or see displayed, depending on your version of the operating system.

• You can use the client graphical user interface.Your product documentation provides details about how to use the graphical user interface.

• You can enter commands either at the switch console or from any client that can obtain access tothe switch using a Telnet session.In examples that illustrate command execution, the command syntax and output shown mightdiffer from what you enter or see displayed, depending on your version of the operating system.

Keyboard and formatting conventionsYou can use your product more effectively when you understand how this document uses keyboardand formatting conventions to present information.

Keyboard conventions

Convention What it means

The IBM NASsupport site

Refers to www.ibm.com/storage/support/nas/.

About this guide | 17

Page 18: N Series Data ONTAP Software Setup Guide

Convention What it means

Enter, enter • Used to refer to the key that generates a carriage return; the key isnamed Return on some keyboards.

• Used to mean pressing one or more keys on the keyboard and thenpressing the Enter key, or clicking in a field in a graphical interface andthen typing information into the field.

hyphen (-) Used to separate individual keys. For example, Ctrl-D means holding downthe Ctrl key while pressing the D key.

type Used to mean pressing one or more keys on the keyboard.

Formatting conventions

Convention What it means

Italic font • Words or characters that require special attention.• Placeholders for information that you must supply.

For example, if the guide says to enter the arp -d hostname command,you enter the characters "arp -d" followed by the actual name of the host.

• Book titles in cross-references.

Monospaced font • Command names, option names, keywords, and daemon names.• Information displayed on the system console or other computer monitors.• Contents of files.• File, path, and directory names.

Bold monospaced

fontWords or characters you type. What you type is always shown in lowercaseletters, unless your program is case-sensitive and uppercase letters arenecessary for it to work properly.

Special messagesThis document might contain the following types of messages to alert you to conditions that youneed to be aware of.

Note: A note contains important information that helps you install or operate the systemefficiently.

Attention: An attention notice contains instructions that you must follow to avoid a system crash,loss of data, or damage to the equipment.

18 | Data ONTAP 7.3 Software Setup Guide

Page 19: N Series Data ONTAP Software Setup Guide

How to send your comments

Your feedback is important in helping us provide the most accurate and high-quality information. Ifyou have comments or suggestions for improving this document, send us your comments by e-mailto [email protected]. Be sure to include the following:

• Exact publication title• Publication form number (for example, GC26-1234-02)• Page, table, or illustration numbers• A detailed description of any information that should be changed

About this guide | 19

Page 20: N Series Data ONTAP Software Setup Guide
Page 21: N Series Data ONTAP Software Setup Guide

Overview of the software setup process

The software setup process consists of satisfying prerequisites, gathering configuration information,entering configuration information at setup prompts, and verifying initial configuration parameters.

Next topics

Software setup stages on page 21

Default storage system configuration on page 22

About the setup process on page 23

Setup methods on page 23

Software setup stagesThe software setup process for your new storage system requires several steps after you havecompleted hardware setup.

Before you begin

This guide assumes that you have already prepared the physical site for your new storage system andthat you have racked and cabled storage system hardware according to your hardware documentationand the Data ONTAP Active/Active Configuration Guide.

Note: The Data ONTAP Active/Active Configuration Guide also includes important informationabout active/active configuration prerequisites and verification procedures that you will need toconsult during the software setup process.

About this task

If your storage system is intended for use with third-party storage (a gateway configuration), youhave additional configuration requirements.

Steps

1. Ensure that your network and storage environment meets storage system requirements.

2. Gather system configuration information and record it in the worksheet provided.

3. Power on the new system.

4. Choose the following option depending on your storage system configuration.

Overview of the software setup process | 21

Page 22: N Series Data ONTAP Software Setup Guide

If you are setting up your storagesystem for using ...

Then ...

Native disk shelves Enter the information you gathered when the setup commandbegins to run.

Only third-party storage Perform gateway configuration tasks in maintenance mode, thenenter the information you gathered when the setup commandbegins to run.

5. Verify that basic system functionality has been configured correctly.

6. Configure system features and provision your features as described in relevant documents of theData ONTAP library.

Related concepts

Prerequisites to initial configuration on page 25

Configuration information you need to gather on page 33

Related tasks

Setting up your storage system for using native disk shelves on page 59

Verifying software setup on page 93

Default storage system configurationBefore your storage system was shipped to you, a series of tasks was performed to configure yourstorage system for use. These tasks simplify the setup process for you and ensure that you can run thesetup script on systems with native disk shelves.

Gateways that use only third-party storage require a number of prerequisite configuration steps andsoftware installation before you run the setup script.

The following tasks were performed on storage systems containing native disk shelves:

• Your storage system was configured at the factory with an aggregate and FlexVol root volume.• The root volume is installed at the factory on filers and, starting with Data ONTAP 7.3, also on

gateway systems ordered with disk shelves.• Licenses for protocols and features (such as CIFS, NFS, and controller failover) you have

purchased were installed on your system.• Bootloader files and firmware updates, including primary and secondary BIOS images, were

installed on the boot device that shipped with your system.

22 | Data ONTAP 7.3 Software Setup Guide

Page 23: N Series Data ONTAP Software Setup Guide

About the setup processThe software setup process collects information that enables the storage system to serve data in yourenvironment.

When Data ONTAP software is installed on your new storage system, the following files are notpopulated:

• /etc/rc• /etc/exports• /etc/hosts• /etc/hosts.equiv• /etc/nsswitch.conf• /etc/resolv.conf

When your new system is powered on for the first time, you can enter configuration values topopulate these files and to configure the installed functionality of your system, depending on yoursystem's hardware configuration and licensed features.

You have the option to enter configuration values manually in the command-line interface, enterconfiguration values manually in a graphical interface, or have configuration values populated frominformation in a DHCP server, depending on the setup method you select. You can also choose toenter all initial configuration values during the setup process or to enter only essential networkingvalues and complete initial configuration at a later time.

Note: For gateways ordered without native disk shelves, you must perform prerequisiteconfiguration steps and install software before running the setup script.

Setup methodsYou can provide initial setup configuration values through the command-line interface or through agraphical interface. These methods require a serial console connection, or a network connection anda DHCP server.

The most common method to set up a new system is to enter configuration values at the storagesystem command-line interface in a serial console session.

When you boot your system for the first time, a DHCP broadcast is issued from the management port(e0M, if your system has one) or from the first onboard network interface (usually e0a). If there is noresponse to the DHCP broadcast, the setup command begins to run automatically on the systemconsole. You can also elect to disregard a DHCP server response and enter configuration values atthe command-line interface.

The setup script collects information to populate configuration files and to configure the installedfunctionality of your system. After the setup command begins to run on the system console, you can

Overview of the software setup process | 23

Page 24: N Series Data ONTAP Software Setup Guide

choose whether to continue setup at the console or using a Web browser. You might also beprompted to respond to setup commands for other system features.

There are several alternatives to a serial console session for initial configuration, all requiring anetwork connection and correctly configured DHCP server. If you have configured a DHCP server inyour environment, it will respond to the DHCP broadcast with an IP address. If you accept theassigned address, you can connect to the storage system using one of the following methods:

• FilerView Setup WizardYou can connect to the storage system's built-in Web server and enter setup values in thegraphical FilerView setup screens.

• System ManagerIf you have installed System Manager software on a Windows client system, you can enter setupvalues at the System Manager console.

Note: System Manager provides setup and management capabilities for SAN and NASenvironments from a Microsoft Windows system. You can use System Manager to quickly andefficiently set up storage systems that are single or in an active/active configuration. You canalso use System Manager to configure all protocols, such as NFS, CIFS, FCP, and iSCSI,supply provisions for file sharing and applications, and monitor and manage your storagesystem. For more information about System Manager, see the IBM NAS support site.

• Telnet clientYou can enter setup values at the command-line interface during a Telnet session.

24 | Data ONTAP 7.3 Software Setup Guide

Page 25: N Series Data ONTAP Software Setup Guide

Prerequisites to initial configuration

Before you begin the software setup process, you must ensure that you have prepared your networkand storage environment for your new storage system.

Next topics

Requirements for the administration host on page 25

Active/active configuration requirements on page 26

Requirements for Windows domains on page 26

Requirements for Active Directory authentication on page 28

Time services requirements on page 29

Switch configuration requirements for vifs on page 30

DHCP requirements for remote access on page 30

Requirements for creating array LUNs for gateways on page 31

Gateway licensing requirements on page 31

Requirements for the administration hostYou should designate a Windows or UNIX client workstation as an administration host to limitaccess to the storage system's root file system, to provide a text editor to edit configuration files, or toprovide the ability to administer a storage system remotely.

During the setup process, you are prompted to designate a workstation on the network as anadministration host. For more information about administration hosts, see the Data ONTAP SystemAdministration Guide.

Windows and UNIX client workstations can serve as administration hosts, with these requirementsand privileges:

• If you plan to use a Windows client to manage the storage system, the Windows client mustsupport the telnet and rsh commands.You can edit configuration files from any Windows client as long as you connect to the storagesystem as root or Administrator.

• If you plan to use a UNIX client to manage the storage system, the UNIX client must meet thefollowing requirements:

• Support a text editor that can display and edit text files containing lines ending with thenewline character

• Support the telnet and rsh commands• Support the mounting of directories using the NFS protocol

When connecting from a UNIX client, the administrator operates as root.

Prerequisites to initial configuration | 25

Page 26: N Series Data ONTAP Software Setup Guide

Attention: If you change the name or IP address of an administration host on a storage system thathas already been set up and configured, the /etc/exports files will be overwritten on system reboot.

Active/active configuration requirementsFor information about preparing your environment for a new active/active pair, see the Data ONTAPActive/Active Configuration Guide.

Requirements for Windows domainsIf you are joining your system to a Windows domain, the storage system administrator account musthave permissions to add the system to an Active Directory domain. It might also be necessary toprecreate a domain account for your new system before initial setup.

Permissions for adding a storage system to an Active Directory domain are the same as permissionsrequired for adding any Windows server.

Note: When you run cifs setup, a Windows directory account is automatically created, unlessyou intend to use Windows NT4-style authentication. To use Windows NT4-style authentication,you must create a domain account using Windows tools before you run cifs setup. If you donot do this, cifs setup will terminate, prompting you to create the domain account.

Next topics

Assigning domain administrator privileges on page 26

Creating a storage system domain account before setting up CIFS on page 27

Assigning domain administrator privilegesBefore adding a storage system to a Windows Active Directory domain, organizational unit (OU), orother Active Directory container object, you need to make sure the storage system administratoraccount has sufficient privileges and permissions to add a Windows Active Directory server to thatdomain or object.

About this task

When the cifs setup program adds the storage system to an Active Directory environment, itcreates an Active Directory domain and joins the storage system’s computer account to that domain.Before this happens, you need to assign permissions on certain domain objects.

Note: The following steps describe the procedure on a Windows 2000 Server. Details of thisprocedure might vary on other Windows server versions.

26 | Data ONTAP 7.3 Software Setup Guide

Page 27: N Series Data ONTAP Software Setup Guide

Steps

1. In the Active Directory Users and Computers View menu, ensure that the Advanced Featuresmenu item is selected.

2. In the Active Directory tree, select the OU for your storage system.

3. Select the user or group that will add the storage system to the domain.

4. In the Permissions list, ensure that the following check boxes are enabled:

• Change Password• Write Public Information• Create Computer Objects

Creating a storage system domain account before setting up CIFSIf your security structure does not allow you to assign the necessary permissions to the setup programin order to create the storage system domain account, or if you intend to use Windows NT4-styleauthentication, you must create the storage system domain account before cifs setup is run.

About this task

If you create the storage system domain account before cifs setup is run, follow these guidelines:

• You do not need to assign the Create Computer Objects permission.• You can assign permissions specifically on the storage system domain account, instead of

assigning them on the storage system container.

Steps

1. In the Active Directory Users and Computers View menu, ensure that the Advanced Featuresmenu item is selected.

2. In the Active Directory tree, locate the Organizational Unit (OU) for your storage system, right-click, and choose New > Computer.

3. Enter the storage system (domain account) name.

Make a note of the storage system name you entered, to ensure that you enter it correctly whenyou run cifs setup later.

4. In the "Add this computer to the domain" field, specify the name of the storage systemadministrator account.

5. Right-click the computer account you just created, and choose Properties from the pop-up menu.

6. Click the Security tab.

7. Select the user or group that will add the storage system to the domain.

Prerequisites to initial configuration | 27

Page 28: N Series Data ONTAP Software Setup Guide

8. In the Permissions list, ensure that the following check boxes are selected:

• Change Password• Write Public Information

After you finish

When cifs setup is run, you will see the prompt "Please enter the new hostname." Enter thestorage system name you specified in Step 3.

Requirements for Active Directory authenticationIf you are deploying your new system in an Active Directory domain with Kerberos authentication,you need to ensure that DNS and network infrastructure are configured correctly before initial systemsetup.

Note: Kerberos 5 authentication depends upon the synchronization of time between the clients andthe Kerberos Key Distribution Centers (KDCs).

Next topics

DNS requirements for Active Directory on page 28

Network infrastructure requirements for Active Directory on page 29

Related concepts

Time services requirements on page 29

Related tasks

Creating a storage system DNS "A" record for CIFS client access on page 99

DNS requirements for Active DirectoryActive Directory Kerberos requires that a standards-based DNS implementation be configured. Theimplementation must support service locator records.

Your DNS solution must have the following capabilities:

• The DNS solution must be standards-based (RFC 1035).• Service locator records must be supported.

Windows 2000 and Windows Server 2003/2008 Active Directory requires service locator recordsfor finding the domain controllers, global catalog servers, Kerberos servers, LDAP servers, andthe KPASSWD servers.

The following additional capabilities are recommended:

• Support for dynamic updates

28 | Data ONTAP 7.3 Software Setup Guide

Page 29: N Series Data ONTAP Software Setup Guide

• Support for incremental zone transfers

The following DNS solutions meet the requirements:

• Microsoft Server 2000/2003 DNSThis Active Directory integrated DNS provides the recommended capabilities. Service locatorrecords are configured automatically.

• Berkeley Internet Name Domain (BIND) DNSIf you use BIND DNS, you need to manually configure the service locator records.

Network infrastructure requirements for Active DirectoryYou should ensure that the infrastructure supports reliable communication between clients, thestorage system, DNS servers, time servers, and Active Directory domain controllers.

Verify the following network infrastructure functionality:

• To ensure that clients can find the Active Directory LDAP and Kerberos servers, there must bereliable network connectivity between the clients and DNS servers containing the LDAP andKerberos service records. If possible, this should be a high-bandwidth connection.

• Clients must have reliable connections to domain controllers that host both the LDAP andKerberos services. If possible, this should be a high-bandwidth connection.

• When the enterprise contains more than one domain or utilizes universal groups, there must beadequate connectivity from domain controllers to a global catalog server. If possible, this shouldbe a high-bandwidth connection.

• If the enterprise is located in multiple locations that have low-bandwidth connectivity, you shouldconfigure Active Directory sites. These sites group resources within a local high-bandwidth zone.

• If clients from other domains access resources on the storage system, there should be reliableconnectivity between the storage system and all domain controllers with users who accessresources on the storage system.

Time services requirementsYou should configure your storage system for time service synchronization. Many services andapplications depend on accurate time synchronization.

During CIFS setup, if the storage system is to be joined to an Active Directory domain, Kerberosauthentication is used. Kerberos authentication requires the storage system's time and the domaincontroller's time to match (within 5 minutes). If the times do not match, setup and authenticationattempts fail.

By default, within Active Directory domains, all domain controllers synchronize to the domaincontroller that is configured as the PDC Emulator Master. Therefore, one of the followingconfigurations is required:

• All storage systems configured to synchronize to one of the domain controllers• Both the storage systems and the controller configured to synchronize to a central time server.

Prerequisites to initial configuration | 29

Page 30: N Series Data ONTAP Software Setup Guide

For more information about time services supported by Data ONTAP, see the Data ONTAP SystemAdministration Guide.

Switch configuration requirements for vifsIf you use virtual network interfaces (vifs), you must ensure that your switches support the vif typerequired for your storage system before powering on for the first time.

If you plan to use this type of vif... Your switch must support...

Dynamic multimode Link Aggregation Control Protocol (LACP)

Static multimode Aggregates (but must not have control packetexchange for configuring an aggregate)

Single-mode No special switch requirements

For more information about vifs, see the Data ONTAP Network Management Guide.

DHCP requirements for remote accessIf you want to complete the setup process from the storage system's Web browser interface (theFilerView Setup Wizard), or a Telnet client rather than the console, you must configure the DynamicHost Configuration Protocol (DHCP).

Note: IBM customer contact information cannot be entered using the Setup Wizard. If you use theSetup Wizard method, you must enter the IBM contact information from the command lineinterface after the setup process has completed.

Note: System Manager has different DHCP requirements than FilerView or Telnet. See theSystem Manager documentation for more information.

When you enable DHCP to assign a static IP address to an onboard network interface during first-time setup, you can connect to the storage system through a Web browser running over HTTP andcomplete the first-time configuration remotely using the FilerView Setup Wizard or a Telnet client.

If your system includes an e0M interface, the system broadcasts a DHCP request through it. If aDHCP server responds, it will assign an IP address to the e0M interface. If your system does nothave an e0M interface, the system uses the first onboard network interface (e0a, or e0 when there isonly one onboard interface) for the DHCP broadcast.

When you use DHCP to assign an IP address to the onboard interface, the storage system performsthe following operations:

• Obtains the address from the DHCP server when the storage system is turned on• Configures the onboard interface with the IP address• Becomes accessible to the Setup Wizard or a Telnet client

30 | Data ONTAP 7.3 Software Setup Guide

Page 31: N Series Data ONTAP Software Setup Guide

You need to configure the following information into your DHCP server prior to running the SetupWizard:

• Storage system MAC address• Storage system fixed IP address• Any of the following optional information:

• Routers• Default route• DNS domain name• DNS servers• NIS domain name• NIS servers• WINS servers• SMTP server

Attention: When you use DHCP with a storage system, you must ensure that the DHCP server isconfigured to return a static IP address for the interface. If the server returns a dynamic IP address,the storage system displays an error message and continues to use the IP address permanently—which can result in an IP address conflict if the DHCP server assigns the IP address dynamically toother clients from time to time.

DHCPv6 servers are not currently supported.

Requirements for creating array LUNs for gatewaysBefore setting up your gateway and installing Data ONTAP software, you must create LUNs on thestorage array and make them available to the system. You provide information through the bootmenu and the setup program to assign array LUN ownership.

Gateway licensing requirementsYou must enter a license to operate the gateway. The license must be installed within 72 hours ofrunning setup or the system shuts down.

Licenses are not preinstalled on a gateway that is ordered without disk shelves. On a gateway that isordered without native disks, you must install the Data ONTAP software after running setup and thenenter any licenses that you purchased. For more information about installing Data ONTAP softwareand licenses, see Installing Data ONTAP software on your system on page 77.

Prerequisites to initial configuration | 31

Page 32: N Series Data ONTAP Software Setup Guide
Page 33: N Series Data ONTAP Software Setup Guide

Configuration information you need to gather

Before powering on your storage system for the first time, you should use the configurationworksheet to gather the information that the software setup process requires.

If you are configuring a storage system as part of an active/active configuration, some informationtypes must be unique for each storage system in the configuration, and some information types mustbe identical on both storage systems. Some of the tables in the following sections have a descriptioncolumn that indicates whether the information type must be unique for each storage system oridentical on both storage systems.

Next topics

Configuration worksheet on page 33

Required storage system information on page 38

Network information on page 39

Virtual network interface information on page 43

HTTP information on page 45

DNS services information on page 46

NIS services information on page 46

CIFS protocol information on page 47

Required IBM customer information on page 52

Baseboard Management Controller information on page 53

Remote LAN Module information on page 54

Service processor information on page 55

Shelf Alternate Control Path Management information on page 56

Configuration worksheetUse the configuration worksheet to record values that you will use during the setup process.

Note: The alternate names used by the Setup Wizard for the term used in the setup commandappear in parentheses.

Configuration information you need to gather | 33

Page 34: N Series Data ONTAP Software Setup Guide

Types of information Your values

Storage system Host name

Password

Time zone

Storage system location

Language used for multiprotocol storagesystems

Administration host Host name

IP address

Virtual interfaces Name of the virtual interface (such as vif0)

Mode type (single, multi, or LACP)

Load balancing type (IP based, MACaddress based, port based, or round-robinbased)

Number of links (number of physicalinterfaces to include in the vif)

Link names (physical interface names suchas e0, e0a, e5a, or e9b)

IP address for the virtual interface

Subnet mask (IPv4) or subnet prefix length(IPv6) for virtual interface

Partner vif name

Media type for virtual interface

34 | Data ONTAP 7.3 Software Setup Guide

Page 35: N Series Data ONTAP Software Setup Guide

Types of information Your values

Ethernet interfaces Interface name

IPv4 Address

Subnet mask

IPv6 Address

Subnet prefix length

Partner IP address or interface

Media type (network type)

Are jumbo frames supported?

MTU size for jumbo frames

Flow control

e0M interface (ifavailable)

IP address

Network mask

Partner IP address

Flow control

Router (if used) Gateway name

IPv4 address

IPv6 address

HTTP Location of HTTP directory

DNS Domain name

Server address 1

Server address 2

Server address 3

NIS Domain name

Server address 1

Server address 2

Server address 3

Configuration information you need to gather | 35

Page 36: N Series Data ONTAP Software Setup Guide

Types of information Your values

CIFS Windows domain

WINSservers

1

2

3

Multiprotocol or NTFS-only filer?

Should CIFS create default /etc/passwdand /etc/group files?

NISgroupcaching

Enable?

Hours to update the cache

CIFS server name (if different from default)

User authentication style:

(1) Active Directory domain authentication(Active Directory domains only)

(2) Windows NT 4 domain authentication(Windows NT or Active Directorydomains)

(3) Windows Workgroup authenticationusing the filer's local user accounts

(4) /etc/passwd and/or NIS/LDAPauthentication

WindowsActiveDirectorydomain

Domain name

Time server name(s) or IPaddress(es)

Windows user name

Windows user password

Local administrator name

Local administrator password

CIFS administrator or group

Active Directory container (command-linesetup only)

36 | Data ONTAP 7.3 Software Setup Guide

Page 37: N Series Data ONTAP Software Setup Guide

Types of information Your values

Customer contact Primary

Name

Phone

Alternate phone

E-mail address or IBM WebID

Secondary

Name

Phone

Alternate phone

E-mail address or IBM WebID

Machine location Business name

Address

City

State

Country code

Postal code

BMC MAC address

IP address

Network mask (subnet mask)

Gateway

Mailhost

Configuration information you need to gather | 37

Page 38: N Series Data ONTAP Software Setup Guide

Types of information Your values

RLM MAC address

IPv4 Address

Subnet mask

Gateway

IPv6 Address

Subnet prefix length

Gateway

AutoSupport mailhost

AutoSupport recipients

ACP Network interface name

Domain for network interface

Netmask (subnet mask) for networkinterface

Required storage system informationYou must provide basic information about the storage system during the setup process. Thisinformation is required regardless of licensed features and usage.

Information type Description

Host name (Hostname or Storage System Name) The name by which the storage system is knownon the network.

If the storage system is licensed for the NFSprotocol, the name can be no longer than 32characters.

If the storage system is licensed for the CIFSprotocol, the name can be no longer than 15characters.

The host name must be unique for each storagesystem in an active/active configuration.

Password (Administrative Password) A password for the root account that the storagesystem requires before granting administrativeaccess at the console, through a Telnet client, orthrough the Remote Shell protocol.

38 | Data ONTAP 7.3 Software Setup Guide

Page 39: N Series Data ONTAP Software Setup Guide

Information type Description

Time zone (Timezone) The time zone in which the storage systemresides. See Time zones on page 109 for a listof valid time zones.

The time zone must be identical on both storagesystems in an active/active configuration.

Storage system location (Location) A description of the physical location of thestorage system. The text you enter during thestorage system setup process is recorded in theSNMP location information. Use a descriptionthat identifies where to find your storage system(for example, "Lab 5, Row 7, Rack B").

Language The language used for multiprotocol storagesystems if both the CIFS and NFS protocols arelicensed. For a list of supported languages andtheir abbreviations, see Supportedlanguages on page 119.

The language must be identical on both storagesystems in an active/active configuration.

Administration host (Administrative Host) A client computer that is allowed to access thestorage system through a Telnet client orthrough the Remote Shell protocol.

Network informationYou must provide basic information about the storage system's network connections. Thisinformation is required regardless of licensed features and usage.

Some of the Internet Protocol information is required both for physical interfaces and for virtualnetwork interfaces (vifs).

For more information about these parameters, see the Data ONTAP Network Management Guide andthe inconfig(1) man page.

Configuration information you need to gather | 39

Page 40: N Series Data ONTAP Software Setup Guide

Information type Description

Network interface name The name of the Ethernet (or GbE) interface,depending on what port the Ethernet card isinstalled in. Examples include e0 and e1 (for aphysical interface on a single-port adapter orslot); and e3a, e3b, e3c, and e3d (for an Ethernetquad-port adapter). Network interface names areautomatically assigned by Data ONTAP as itdiscovers them.

e0M interface (if available) The network interface of the management port(if included in your system). You can use thee0M interface to access the storage system withprotocols such as Telnet, RSH, and SNMP, aswell as monitoring tools such as OperationsManager. This enables you to separatemanagement traffic from data traffic on yourstorage system.

Note: The e0M interface cannot be includedin vif or VLAN configurations.

For more information about using the e0Minterface to access your system, see the DataONTAP System Administration Guide.

40 | Data ONTAP 7.3 Software Setup Guide

Page 41: N Series Data ONTAP Software Setup Guide

Information type Description

Internet Protocol You are prompted to configure IPv6. If youenter n, further prompts will be for IPv4 valuesonly.

If you enter y to configure IPv6, you must alsosupply IPv4 configuration information fornetwork interfaces in addition to IPv6configuration information.

Note: Enabling IPv6 during setup does notenable file access protocols (CIFS, NFS, FTP,or HTTP) over IPv6. For more informationabout using these protocols over IPv6, see theData ONTAP File Access and ProtocolsManagement Guide.

Enabling IPv6 during setup also enables IPv6router advertisement. This can be disabledseparately by setting the ip.v6.ra_enableoption to off.

For more information about IPv4 and IPv6support, see the Data ONTAP NetworkManagement Guide.

IP address A unique address for each network interface.

IPv4 example: 192.0.2.66

IPv6 example: 2001:0DB8:85A3:0:0:8A2E:0370:99

Subnet mask (Network Mask, IPv4 only) The IPv4 subnet mask for the network to whicheach network interface is attached.

Example: 255.255.255.0

Subnet prefix length The number of bits used as the subnet mask forthe specified interface.

For an IPv6 address, the prefix length must beless than or equal to 128 bits. The default valueof prefix length is 64 bits.

Configuration information you need to gather | 41

Page 42: N Series Data ONTAP Software Setup Guide

Information type Description

Partner IP address (Interface to Take Over) If your storage system is licensed for controllertakeover, record the interface name or IP addressbelonging to the partner that this interfaceshould take over during an active/activeconfiguration takeover.

Examples: e0 or 10.10.10.2When configuring vifs, you must specify the vifname rather than the IP address.

Note: You can specify only an IPv4 addressfor takeover in an active/active configuration.

Media type (Network Type) If the network interface is Gigabit or 10 GigabitEthernet, you do not need to configure the mediatype because these interfaces support only onespeed and duplex, or they can identifyswappable media modules.

If the network interface is 10/100 or10/100/1000 Ethernet, you can selectautonegotiation or you can explicitly configurethe speed and duplex using these media types:

auto Autonegotiate speed and duplex

100tx-fd 100Base-TX, full-duplex

100tx 100Base-TX, half-duplex

tp-fd 10Base-T, full-duplex

tp 10Base-T, half-duplex

The switch must be configured to match themedia type values you select.

42 | Data ONTAP 7.3 Software Setup Guide

Page 43: N Series Data ONTAP Software Setup Guide

Information type Description

Flow control The management of the flow of frames betweentwo directly connected link-partners. Options:

none No flow control

receive Ability to receive flow controlframes

send Ability to send flow controlframes

full Ability to send and receive flowcontrol frames

Router (Routing Gateway) Record the following information for theprimary gateway to use for routing outboundnetwork traffic:

• Gateway name• IP address of the router for IPv4 routing• IP address of the router for IPv6 routing

Virtual network interface informationIf you want to use virtual network interfaces (vifs), you should plan for them before installation andcreate them during the software setup process.

During setup, you are first prompted to enter the number of vifs that you want to configure. Youmust then enter configuration information for each vif name you specify.

Note: The interface group information must be identical on both storage systems in an active/active configuration.

For more information about vifs and assigning the correct configuration values for your environment,see the Data ONTAP Network Management Guide.

Configuration information you need to gather | 43

Page 44: N Series Data ONTAP Software Setup Guide

Information type Description

Name of vif Assign a name for the vif, for example, vif0.

Interface group names are user specified. Aninterface group's name should meet thefollowing criteria:

• It must begin with a letter.• It must not contain any spaces.• It must not contain more than 15 characters.• It must not already be in use for an interface

group.

Vif type Select one of the following values:

• single [s]

Single-mode• multi [m]

Static multimode• lacp [l]

Dynamic multimode

Note: You must ensure that the value youselect corresponds to your network switchconfiguration. For more information, see"Switch configuration requirements for vifs."

Load balancing type Select one of the following values:

• IP based [i]

• MAC based [m]

• Round-robin based [r]

• Port based [p]

Note: Load balancing is applicable only formultimode vifs.

It is best to use the IP address load-balancingmethod with dynamic multimode vifs.

Number and names of links Record the number of physical interfaces to beincluded in the vif and the name of each physicalinterface.

44 | Data ONTAP 7.3 Software Setup Guide

Page 45: N Series Data ONTAP Software Setup Guide

Information type Description

Internet Protocol information Record the following information:

• IP address (IPv4 or IPv6)• Subnet mask (IPv4)• Subnet prefix length (IPv6)• Media type

For more information, see "Networkinformation."

Partner vif name Record the vif name (not the IP address)belonging to the active/active partner that thisinterface should take over.

Related concepts

Switch configuration requirements for vifs on page 30

Network information on page 39

HTTP informationIf your storage system is licensed for HTTP, you must designate a directory from which Web filesand directories are served or accept the default.

If you purchased an HTTP license, Web browsers can access all of the files in the HTTP server's rootdirectory (or other directory you designate); otherwise, Web browsers can access the man pages andFilerView only. You can also connect a third-party HTTP server to your storage system. For moreinformation about file access using HTTP, see the Data ONTAP File Access and ProtocolsManagement Guide.

Note: It is not necessary to specify the HTTP directory if you want to provide administrativeaccess to your system using HTTP.

Information type Description

Location of the HTTP directory The directory where the Web files anddirectories are stored. The default directory is /home/http in the storage system’s root volume.

The /home/http path can be used by both HTTPand HTTPS.

Configuration information you need to gather | 45

Page 46: N Series Data ONTAP Software Setup Guide

DNS services informationTo configure your storage system to use the Domain Name System (DNS), you must provide DNSdomain and server names.

For more information about configuring DNS, see the Data ONTAP Network Management Guide.

Information type Description

DNS domain The name of your network’s DNS domain.

The DNS domain name must be identical on both storage systems in anactive/active configuration.

Note: The domain name cannot contain an underscore (_) and mustconsist of alphanumeric characters. If you use an underscore, youreceive a “bad domain name” message.

DNS servers The IP addresses of your DNS servers.

If... You need the IP addresses of...

Your storage system will not useActive Directory services

One or more DNS servers thatprovide host-name lookup servicesto the storage system.

Note: If you are enabling IPv6,you can enter IPv6 DNS serveraddresses here.

You want to make ActiveDirectory services available toCIFS

DNS servers that support yourWindows Active Directory domain.

NIS services informationIf your network uses the Network Information Service (NIS), you must provide NIS domain andserver names.

For more information about configuring NIS, see the Data ONTAP Network Management Guide.

46 | Data ONTAP 7.3 Software Setup Guide

Page 47: N Series Data ONTAP Software Setup Guide

Information type Description

NIS domain The name of your NIS domain. The storage system can use an NISdomain to authenticate users and client computers.

The NIS domain name must be identical on both storage systems if yournetwork uses NIS.

If multiprotocol access is enabled on the storage system, group caching isbeneficial for CIFS access as well as NFS access. With multiprotocolaccess, user mapping of CIFS users to NFS users is performed. When aWindows user requests access to data with UNIX security style, theWindows user is first mapped to the corresponding UNIX user. The UNIXusers’ groups must then be ascertained before the storage system candetermine appropriate access. Failure to enable these two options togethercould lead to slow CIFS access to resources due to time spent on NISgroup lookups.

NIS servers The host names of your preferred NIS servers.

If... You need...

Your site uses NIS The host names of your NIS servers.

Note: If you are enabling IPv6,you can enter IPv6 NIS serveraddresses here.

You want NIS to broadcast to finda server

To enter an asterisk (*) when askedfor the NIS server names.

CIFS protocol informationIf your storage system is licensed for the CIFS protocol, the cifs setup command runsautomatically when basic setup has finished. You must provide information about the Windowsdomain, WINS servers, the Active Directory service, and your configuration preferences.

For more information about configuring CIFS, see the Data ONTAP File Access and ProtocolsManagement Guide.

Configuration information you need to gather | 47

Page 48: N Series Data ONTAP Software Setup Guide

Information type Description

Windows domain The name of your Windows domain. If your site uses Windows domainsand the storage system belongs to one of these domains, record the nameof the domain to which the storage system should belong.

Note: The Windows domain name value does not need to be identicalon both storage systems in an active/active configuration. Each storagesystem in an active/active configuration can exist in a different domainand/or workgroup from its partner. If you have a multiprotocolenvironment and use UID to Secure ID (SID) mapping, the UNIXsecurity information must be compatible between the two domains.

WINS servers The servers that handle Windows Internet Name Service (WINS) nameregistrations, queries, and releases. If you choose to make the storagesystem visible through WINS, you can record up to four WINS IPaddresses.

Note: The WINS server value does not need to be identical on bothstorage systems in an active/active configuration. Each storage systemin an active/active configuration can exist in a different domain and/orworkgroup from its partner.

Multiprotocol orNTFS-only

The setup utility determines if your system includes licenses for multiplefile access protocols (to serve data to NFS, Windows, HTTP, and otherclients) or for NTFS only (to serve data to Windows clients only).

Default /etc/passwdand /etc/group files

When prompted whether you want CIFS to create default passwd andgroup files, enter

y

if you have a multiprotocol environment. Default UNIX accounts arecreated that are used for performing user mapping. As an alternative tostoring this information in local files, you can store the generic useraccounts in the NIS or LDAP databases. However, when generic accountsare stored in the local passwd file, mapping of a Windows user to ageneric UNIX user and mapping of a generic UNIX user to a Windowsuser work better than when generic accounts are stored in NIS or LDAP.

If generic accounts are configured, storage administrators should bemindful to not grant these generic accounts undue access to data.Additionally, creation of the local passwd and group file might bedesirable if you select "/etc/passwd and/or NIS/LDAP authentication". Ifyou choose this option, the storage system can use either the local files orNIS/LDAP for storing user information used for CIFS authentication. Inthis scenario, choosing to store the information in local files allowsauthentication to continue even during times where NIS and /or LDAP areconfigured and these services are unavailable.

48 | Data ONTAP 7.3 Software Setup Guide

Page 49: N Series Data ONTAP Software Setup Guide

Information type Description

NIS group caching NIS group caching is used when access is requested to data with UNIXsecurity style. UNIX file and directory style permissions of rwxrwxrwxare used to determine access for both Windows and UNIX clients. Thissecurity style uses UNIX group information.

Note: If NIS is enabled but NIS group caching is disabled, there can bea severe impact on CIFS authentication if the NIS servers are slow torespond or unavailable. It is highly recommended that you enable NISgroup caching.

By default, the NIS group cache is updated once a day at midnight. Youcan update the cache more often or at different times, depending on yourpreferences.

CIFS server name By default, the CIFS server is the same as the system host name. You canselect a different name for the CIFS server, although the name can be nolonger than 15 characters.

Configuration information you need to gather | 49

Page 50: N Series Data ONTAP Software Setup Guide

Information type Description

User authentication forCIFS services

Data ONTAP CIFS services support four styles of user authentication:

1. Active Directory domain authentication (Active Directory domainsonly)Users are authenticated with the domain controller in an ActiveDirectory domain using Kerberos authentication.If you select this option, you are also prompted for other ActiveDirectory configuration parameters.

2. Windows NT 4 domain authentication (Windows NT or ActiveDirectory domains)Users are authenticated with the domain controller in an ActiveDirectory or an NT domain using NT-style NTLM authentication only.

3. Windows Workgroup authentication using the filer's local useraccountsUsers are authenticated with the storage system’s local user databaseusing NT-style NTLM authentication. A maximum of 97 local users issupported, and local users can be members of the local groups (localuser and group SIDs are used). Local users and groups are managedwith the useradmin command.

4. /etc/passwd and/or NIS/LDAP authenticationUsers are authenticated on the basis of user names and passwords thatare stored in the UNIX directory stores. Even if local Windows usersare created on the storage system using the useradmin command,they are not used for session authentication. All authentication is donebased on UNIX user information stored in the UNIX identity stores.

You should select an authentication style appropriate to the storagesystem's environment and to the clients requesting the authenticatedsession. For more information about CIFS authentication, see the DataONTAP File Access and Protocols Management Guide.

Active Directorydomain name

Enter the fully qualified domain name of the domain; for example,example.com.

50 | Data ONTAP 7.3 Software Setup Guide

Page 51: N Series Data ONTAP Software Setup Guide

Information type Description

Active Directory timeservices

In Active Directory-based domains, it is essential that the storage system'stime match the domain controller's time so Kerberos-based authenticationsystem works correctly. If the time difference between the storage systemand the domain controllers is more than 5 minutes, CIFS authenticationfails.

The time services configuration should be identical on both storagesystems in an active/active configuration.

When you configure Active Directory time services, you are prompted forthe host name and IP address of the time server you wish to use, as well asfor additional backup servers if desired.

Windows domainadministrator username (Windows username)

The user name of a Windows domain administrator with sufficientprivileges to add this storage system to the Windows domain. Joining adomain requires an administrator user and password. This also applies toNT4 domains.

Windows domainadministratorpassword (Windows2000 administratorpassword)

The password for the domain administrator user account. Joining a domainrequires an administrator user and password. This requirement also appliesto NT4 domains.

Attention: Before you enter the password, be sure to create a secureconnection (HTTPS); otherwise, the password is sent to the storagesystem unencrypted.

CIFS administrator You can specify an additional user or group to be added to the storagesystem's local "BUILTIN\Administrators" group, thus giving themadministrative privileges as well.

Configuration information you need to gather | 51

Page 52: N Series Data ONTAP Software Setup Guide

Information type Description

Active Directorycontainer

The Windows Active Directory container in which to place storage systemaccounts. This can be either the default Computers container or apreviously created organizational unit (OU) on which you have thenecessary permission to join the storage system to the domain. All OUsfor which you have appropriate permissions will be displayed; the desiredOU can be chosen from this list. If the person running setup does nothave appropriate rights to the OU which will hold the storage systemobject, another user who does have the necessary permissions can bedesignated during the "join" step.

Example:CIFS - Logged in as [email protected].

The user that you specified has permission to createthe storage system's machine account in several (7)containers. Please choose where you would like thisaccount to be created.

(1) CN=computers(2) OU=java_users (3) OU=Engineer,OU=java_users (4) OU=Market,OU=java_users (5) OU=Filers (6) OU=Domain Controllers (7) None of the above

Choose 7:

Selection (1-7)? [1]: 7The user you specified, '[email protected]', may create thefiler's machine account in the container(s)listed above. To use another container, youmust specify a user with the appropriateprivileges.

Enter the name of the Windows user []:'

Required IBM customer informationYou must provide contact information about the individuals responsible for maintaining your storagesystem and information about the system's location.

Numbers in parentheses indicate the maximum number of characters that can be entered for anyvalue. Mandatory entries are indicated with asterisks (*).

52 | Data ONTAP 7.3 Software Setup Guide

Page 53: N Series Data ONTAP Software Setup Guide

Information type Description

Customer contact Contact information for the Primary andSecondary Contacts.

• Name (50) *• Phone (16) *• Alternate phone (16)• E-mail address or IBM WebID (100)

Machine location Business site where the storage system islocated.

• Business name (50) *• Address (105) *• City (50) *• State (55)• Country code (2) *• Postal code (10)

See Country codes on page 121 for a list ofvalid entries.

Baseboard Management Controller informationIf your storage system has a Baseboard Management Controller (BMC), the bmc setup commandruns automatically when basic setup has finished. You must provide information about the BMCsnetwork interface and network connections.

Note: You can also configure the BMC by using one of the following methods after the initialsetup process:

• Running the Data ONTAP setup scriptThe setup script ends by initiating the bmc setup command.

• Running the Data ONTAP bmc setup command

For more information about the BMC, see the Data ONTAP System Administration Guide.

Configuration information you need to gather | 53

Page 54: N Series Data ONTAP Software Setup Guide

Information type Description

Media Access Control (MAC) address If you are using DHCP addressing, you need theMAC address of the BMC. You can obtain theaddress from the MAC address label on theBMC or by using by using the bmc statuscommand (if you configure the BMC after initialsystem setup).

Note: DHCPv6 servers are not currentlysupported.

IP address If you are not using DHCP service, record anavailable IP address for the BMC.

Note: Currently, you can use only IPv4addresses to connect to the BMC.

Network mask If you are not using DHCP service, record thenetwork mask of your network.

Gateway If you are not using DHCP service, record the IPaddress for the gateway of your network.

Mail host The name or IP address of the preferred mailhost. The BMC uses the same mailhostinformation that Data ONTAP uses forAutoSupport.

Remote LAN Module informationIf your storage system has a Remote LAN Module (RLM), you must provide information about theRLM's network interface and network connections.

If you are running RLM firmware version 4.0 or later, and you have enabled IPv6 for Data ONTAP,you have the option to configure the RLM for only IPv4, for only IPv6, or for both IPv4 and IPv6.

Attention: If you disable both IPv4 and IPv6, and if DHCP is also not configured, the RLM has nonetwork connectivity.

For more information about configuring your RLM, see the Data ONTAP System AdministrationGuide.

54 | Data ONTAP 7.3 Software Setup Guide

Page 55: N Series Data ONTAP Software Setup Guide

Information type Description

Media Access Control (MAC) address If you are using DHCP addressing, record theMAC address of the RLM. You can obtain theaddress from the MAC address label on theRLM or by using the sysconfig -v command(if you configure the RLM after initial systemsetup).

Note: You do not need to record IP andgateway addresses if you are using DHCPaddressing for the RLM.

DHCPv6 servers are not currently supported.

IP address Record an available IP address for the RLM.

Note: You can enter an IPv4 address, an IPv6address, or both depending on how youconfigured your storage system.

Network mask Record the IPv4 network mask of your network.

Subnet prefix length Record the number of bits used as the subnetmask for the specified IPv6 interface.

Gateway Record the IP address for the gateway of yournetwork.

Note: You can enter an IPv4 address, an IPv6address, or both depending on how youconfigured your RLM.

Mail host Record the name or IP address of the preferredmail host. The mail host delivers RLM alerts tothe same destination as AutoSupport e-mail.

Service processor informationIf your system includes a Service Processor (SP), you must provide information about the SP'snetwork interface and Autosupport settings.

The following is the information you need to gather:

• Network informationYou can configure for the SP to use DHCP or static addressing. If you are using an IPv4 addressfor the SP, you need the following information:

Configuration information you need to gather | 55

Page 56: N Series Data ONTAP Software Setup Guide

Information type Description

IP address Record an available IP address for the RLM.

If you are using IPv6 for static addressing, youneed the IPv6 global address.

Network mask Record the network mask of your network.

Subnet prefix length Record the number of bits used as the subnetmask for the specified IPv6 interface.

Gateway Record the IP address for the gateway of yournetwork.

Note: If you are using IPv6 for staticaddressing, use the IPv6 gateway.

For information about network interfaces and management, see the Data ONTAP NetworkManagement Guide.

• AutoSupport informationThe SP sends event notifications based on the following AutoSupport settings:

• autosupport.to • autosupport.mailhost

You should set at least the autosupport.to option before configuring the SP. Data ONTAPautomatically sends AutoSupport configuration to the SP, allowing the SP to send alerts andnotifications through an AutoSupport message to your internal support organization. You areprompted to enter the name or the IP address of the AutoSupport mail host when you configurethe SP.

Note: The SP does not rely on the storage system’s autosupport.support.transportoption to send notifications. The SP uses the Simple Mail Transport Protocol (SMTP).

Shelf Alternate Control Path Management informationIf you are planning to attach SAS disk shelves to your system, you should configure ShelfAlternate Control Path Management (ACP) during the software setup process.

Note: ACP connections must be cabled before you enter ACP configuration parameters on thestorage system.

You can also configure ACP by using one of the following methods after the initial setup process:

• Running the Data ONTAP setup scriptYou can run the setup command and enter ACP configuration information.

• Setting the acp.enabled option to on

56 | Data ONTAP 7.3 Software Setup Guide

Page 57: N Series Data ONTAP Software Setup Guide

If the option has not previously been set, you will be prompted for ACP configuration values.

For more information about ACP configuration, see the Universal SAS and ACP Cabling Guide.

Information type Description

Network interface name The name of the Ethernet (or GbE) interface thatwill be used exclusively for ACP traffic.

Domain for network interface The network name (an IP address ending in 0)for the private subnet to be used exclusively byACP. The default is 198.15.1.0.

Netmask for network interface The subnet mask for the ACP interface.

The ACP subnetThe ACP subnet is a private Ethernet network that enables the ACP processor in the SAS module tocommunicate both with Data ONTAP and with the SAS IOMs in the disk shelves.

The ACP subnet is separate from the I/O data path that connects the disk shelves to the HBA on thestorage controller. When you configure ACP on one of the system's network interfaces, you mustsupply a private domain name that conforms to the standard for private internet addresses(RFC1918). You can use the system default domain, 198.15.1.0, or another network name (that is, anIP address ending in 0) that conforms to the standard.

If you are configuring ACP for disk shelves attached to an active/active configuration, you mustsupply the same ACP domain name and network mask for both systems.

Attention: Do not connect the ACP port to a routed network, and do not configure switches orhubs between the ACP port and the designated Ethernet port. Doing so is not supported and causesinterruptions in service.

After you select a domain name and network mask for the interface, Data ONTAP automaticallyassigns IP addresses for the ACP interface on the storage controller and both I/O modules on eachdisk shelf on the ACP subnet.

You can use the sysconfig -v command to check whether your ACP subnet is cabled correctly. IfACP is disabled, sysconfig shows ACP connectivity as "NA".

Configuration information you need to gather | 57

Page 58: N Series Data ONTAP Software Setup Guide
Page 59: N Series Data ONTAP Software Setup Guide

Setting up your storage system for using nativedisk shelves

When you power on a storage system for the first time, the setup command begins to runautomatically and prompts you for configuration information. You must enter the information youcollected in the configuration worksheet by responding to prompts on the command line or from agraphical interface.

Before you begin

If your system does not boot when you power it on for the first time, you must troubleshoot yourhardware configuration before proceeding to software setup.

Note: You should carefully review the setup procedures and gather configuration informationbefore powering on your system for the first time. After the setup script begins to run, you do nothave the option of returning to previous steps to make corrections. If you make a mistake, youmust complete the setup process and reboot your system, then begin the setup process again byentering setup at the command line.

About this task

After responding to prompts to designate an administration host machine, you can continue setting upyour storage system using either the setup command (responding to prompts from the command-line interface) or a graphical interface (the Setup Wizard or System Manager).

If CIFS is licensed for your storage system, you will also be prompted for CIFS configurationinformation.

Next topics

Responding to setup command prompts on page 60

Responding to FilerView Setup Wizard prompts on page 64

Responding to cifs setup prompts on page 66

Responding to rlm setup prompts on page 68

Responding to sp setup prompts on page 70

Additional steps required to set up gateways using native disk shelves and third-partystorage on page 72

Setting up your storage system for using native disk shelves | 59

Page 60: N Series Data ONTAP Software Setup Guide

Responding to setup command promptsThe setup command begins running at the storage system command prompt, where you must enterthe information you gathered.

Before you begin

You must power on your storage system components and external switches following the instructionsin the Installation and Setup Instructions for your hardware platform.

After the storage system boots, Data ONTAP begins discovering devices, interfaces, and licensesinstalled in the system. Data ONTAP displays messages on the console and starts the setup process,prompting you to enter setup information.

Note: Storage system components and external switches must be powered up in the correct order.The order is especially important the first time you boot the system to ensure that initialconfiguration is completed correctly.

About this task

Each step displays the setup command prompt. You should supply an appropriate response from theconfiguration worksheet.

Steps

1. Choose the following option that describes your configuration.

If you are... Then...

Using a DHCP server to assign IP addresses to yourstorage system

Allow the DHCP search to finish, then go to thenext step.

Not using a DHCP server to assign IP addresses toyour storage system

Press Ctrl-C to skip the DCHP search, then go tothe next step.

2. Please enter the new hostname.

You can name this host whatever you wish (for example, host1).

3. Do you want to enable IPv6?

You can type either y or n at this prompt.

If you type... Then you are prompted to enter...

y IPv6 configuration information in later steps.

n IPv4 configuration information in later steps.

60 | Data ONTAP 7.3 Software Setup Guide

Page 61: N Series Data ONTAP Software Setup Guide

Note: If you are configuring IPv6 for this system's network interfaces, you must also enterIPv4 configuration information when prompted. If you are only configuring IPv4 for thissystem's network interfaces, you do not need to enter IPv6 information.

4. Do you want to configure virtual network interfaces?

You can type either y or n at this prompt.

If you type... Then you are...

y Prompted to enter additional configuration information for the virtual interface. Theseprompts are:

• Number of virtual interfaces to configure.

• Name of virtual interface.

• Is vif1 a single [s], multi [m] or a lacp [l] virtualinterface?

• Number of links for (virtual interface).

• Name of link for (virtual interface).

n Directed to the next prompt.

5. Please enter the IP address for Network Interface e0a

Enter the correct IP address for the network interface that connects the storage system to yournetwork (for example, 192.168.1.1).

6. Please enter the netmask for Network Interface e0a.

After entering the IP address, you need to enter the netmask for your network (for example,255.255.255.0).

If you are configuring... Then go to...

IPv6 The next step

IPv4 Step 8

7. Please enter the IPv6 address for Network Interface e0a

Enter the correct IPv6 address for the network interface that connects the storage system to yournetwork (for example, 2001:0DB8:85A3:0:0:8A2E:0370:99).

8. Please enter the subnet prefix length for Network Interface e0a [64]

Enter the number of bits used as the subnet mask for the specified interface; the default is 64.

9. Should interface e0a take over a partner IP address during failover?

Type either y or n at this prompt.

Setting up your storage system for using native disk shelves | 61

Page 62: N Series Data ONTAP Software Setup Guide

If you type... Then you are...

y Prompted to enter the IPv4 address or interface name to be taken over by e0a.

Note: If you type y, you must already have purchased a license for controller failover toenable this function.

n Directed to the next prompt.

10. Please enter media type for e0a (100tx-fd, tp-fd, 100tx, tp, auto(10/100/1000))

Enter the media type that this interface should use.

11. Please enter flow control for e0a {none, receive, send, full} [full]

Enter the flow control option that this interface should use.

12. Do you want e0a to support jumbo frames? [n]

Specify whether you want this interface to support jumbo frames.

13. Continue to enter network parameter values for each network interface when prompted.

14. Would you like to continue setup through the Web interface?

If you want to... Enter...

Continue setup with the Setup Wizardin a Web browser.

y

Go to Responding to Setup Wizard prompts on page 64.

Note: You cannot use the Setup Wizard if you want toconfigure IPv6 connections.

Continue to use the command-lineinterface.

n

Proceed to the next step.

15. Please enter the name or IP address of the IPv4 default gateway.

Enter the primary gateway that is used to route outbound network traffic.

If you are configuring... Then go to...

IPv6 The next step

IPv4 Step 16

16. Please enter the name or IPv6 address of the IPv6 default gateway.

Enter the primary gateway that is used to route outbound IPv6 network traffic.

17. Please enter the name or IP address for administrative host.The administration host is given root access to the storage system's /etc files for system administration.To allow /etc root access to all NFS clients enter RETURN below.

62 | Data ONTAP 7.3 Software Setup Guide

Page 63: N Series Data ONTAP Software Setup Guide

Attention: If you change the name or IP address of an administration host on a storage systemthat has already been set up and configured, the /etc/exports files will be overwritten on systemreboot.

18. Please enter the IP address for (name of admin host).

Enter the IP address of the administration host you specified earlier (for example, 192.175.4.1).

Note: The name listed here is the name of the host entered in the previous step.

19. Please enter timezone

GMT is the default setting. Select a valid value for your time zone and enter it here.

See Time zones on page 109 for a list of supported values.

20. Where is the filer located?

This is the actual physical location where the storage system resides (for example, Bldg. 4, Floor2, Room 216).

21. What language will be used for multiprotocol files?

Enter the language.

See Supported languages on page 119 for a list of supported values.

22. Enter the root directory for HTTP files

This is the root directory for the files that the storage system will serve through HTTP or HTTPS.

23. Do you want to run DNS resolver?

If you type y at this prompt, you need the DNS domain name and associated IP address.

24. Do you want to run NIS client?

If you type y at this prompt, you will be prompted to enter the name of the NIS domain and theNIS servers.

When you have finished with the NIS prompts, you see an advisory message regardingAutoSupport and you are prompted to continue.

25. Would you like to configure the BMC LAN interface?

If you have a BMC installed in your system and you want to use it, type y at the prompt and enterthe BMC values you collected.

26. Would you like to configure the RLM LAN interface?

If you have an RLM installed in your system and you want to use it, type y at the prompt andenter the RLM values you collected.

27. Name of primary contact (Required)Phone number of primary contact (Required)Alternate phone number of primary contactPrimary Contact e-mail address or IBM WebIDName of secondary contact

Setting up your storage system for using native disk shelves | 63

Page 64: N Series Data ONTAP Software Setup Guide

Phone number of secondary contactAlternate phone number of secondary contactSecondary Contact e-mail address or IBM WebID

Enter the customer contact information.

The name and phone number values for a Primary Contact are mandatory.

28. Business name (Required)Business address (Required)City where business resides (Required)State where business resides2-character country code (Required)Postal code where business resides

Enter the machine location information.

The business name, address, city, and country code values are mandatory. See Countrycodes on page 121 for a list of supported values.

29. Do you want to configure the Shelf Alternate Control Path Managementinterface for SAS shelves?

If you are planning to attach SAS disk shelves to your system, type y at the prompt andenter the ACP values you collected.

30. When setup is complete, to transfer the information you've entered to the storage system, enterthe following command, as directed by the prompt on the screen.

reboot

Attention: If you do not enter reboot, the information you entered does not take effect and islost.

31. If you are configuring a pair of storage systems in an active/active configuration and have notconfigured the other storage system, repeat these instructions to set up the other storage system inthe configuration.

Responding to FilerView Setup Wizard promptsIf you have a DHCP server in your environment, you can use the FilerView Setup Wizard tocomplete initial configuration of your storage system.

Before you begin

You must configure a DHCP server as described in "DHCP requirements for remote access" in orderto use the Setup Wizard. If you do not configure this information into your DHCP server, thecorresponding fields in the Setup Wizard will be empty, and you will need to enter the informationmanually into the Setup Wizard fields.

64 | Data ONTAP 7.3 Software Setup Guide

Page 65: N Series Data ONTAP Software Setup Guide

About this task

You can use the FilerView Setup Wizard as an alternative to command-line setup procedures on thesystem console.

However, if you do not have a DHCP server, you can begin the setup process at the console andswitch to the Setup Wizard. If you select y at the Web interface prompt (Step 14 of "Responding tosetup command prompts"), a message is displayed with the name and IP address where you can use aWeb browser and the FilerView application to properly configure your storage system. FilerViewdisplays a system status screen with system information in the center frame and configuration optionslisted in the left frame.

Steps

1. From a storage system client's Web browser, enter the following URL:

http://ip_address/api

ip_address is the IP address for your storage system.

ExampleIf the IP address of the onboard Ethernet interface (named e0a) is 10.14.26.99, enter thefollowing:

http://10.14.26.99/api

The browser displays the Setup Wizard startup page.

2. Fill in the Setup Wizard fields using the information you gathered earlier.

3. After you verify that the configuration information is correct as shown on the last screen, clickFinish.

4. If you are configuring a pair of storage systems in an active/active configuration and have notconfigured the other storage system, repeat these instructions to set up the other storage system inthe configuration.

Related concepts

DHCP requirements for remote access on page 30

Related tasks

Responding to setup command prompts on page 60

Setting up your storage system for using native disk shelves | 65

Page 66: N Series Data ONTAP Software Setup Guide

Responding to cifs setup promptsIf you have a valid CIFS license, cifs setup starts automatically upon completion of the SetupWizard or the setup command (unless cifs setup was run previously).

About this task

Each step displays the cifs setup command prompt. You should supply an appropriate responsefrom the configuration worksheet.

Steps

1. Do you want to make the system visible via WINS?

The system first determines if WINS should be configured. If you want to configure WINS, entery.

2. (1) Multiprotocol filer(2) NTFS-only filer

You are asked if you wish to configure the storage system for multiple protocols or for NTFSonly. If you have purchased multiprotocol licenses (NFS, CIFS, HTTP, and so on), enter 1.

3. Should CIFS create default /etc/passwd and /etc/group files?

Enter y here if you have a multiprotocol environment.

4. Would you like to enable NIS group caching?

You should enable NIS group caching.

If you enable NIS group caching, you also see the following prompts:Enter the hour(s) when NIS should update the group cache [24].Would you like to specify additional hours?

Enter the hours you prefer or accept the default.

5. When the default name of the CIFS server is listed, you see the following prompt:Would you like to change this name?

If you wish to specify a different name, you can enter it here.

6. Select the style of user authentication appropriate to your environment:(1) Active Directory domain authentication (Active Directory domainsonly)(2) Windows NT 4 domain authentication (Windows NT or Active Directorydomains)(3) Windows Workgroup authentication using the filer's local useraccounts(4) /etc/passwd and/or NIS/LDAP authentication

66 | Data ONTAP 7.3 Software Setup Guide

Page 67: N Series Data ONTAP Software Setup Guide

If you selected ... Then ...

1 Go to the next step.

2, 3, or 4 Go to Step 10, then see the Data ONTAP File Access and Protocols ManagementGuide for more information about CIFS setup for these authentication options.

7. What is the name of the Active Directory domain?

Enter the fully qualified domain name.

8. Would you like to configure time services?

It is recommended that time services be available to storage systems in an Active Directorydomain.

If you answer y, respond to the following prompts:Enter the time server host(s) and/or addresses?Would you like to specify additional time servers?

9. Enter the name of the Windows user. Enter the password for the domain.

Enter the name and password of a Windows account with sufficient privileges to add computersto the Active Directory domain.

If you enter a Windows user name and password, you will be prompted to supply ActiveDirectory container names in which to create machine accounts for the storage system.

10. Do you want to create the (name of filer) administrator account?

You should create a local administrator account.

If you answer y, respond to the following prompts:Enter the new password for (storage system name).Retype the password.

11. Would you like to specify a user or group that can administer CIFS?

If you answer y, respond to the following prompt:Enter the name of a user or group that will administer CIFS on thefiler.

Result

After you complete this step, CIFS is configured and the name registrations are complete. You seethe following message:CIFS local server is running.

Setting up your storage system for using native disk shelves | 67

Page 68: N Series Data ONTAP Software Setup Guide

Responding to rlm setup promptsIf your system includes an RLM, rlm setup starts automatically after the setup command (of thecifs setup if CIFS is licensed on your system).

About this task

For each step, you should supply an appropriate response from the configuration worksheet.

Steps

1. When the RLM setup asks you whether to configure the RLM, enter y.

If you answer n here, you can configure the RLM at a later time.

2. Do one of the following when the RLM setup asks you whether to enable DHCP on the RLM.

• To use DHCP addressing, enter y.• To use static addressing, enter n.

3. If you do not enable DHCP for the RLM, the RLM setup prompts you for static IP information.Provide the following information when prompted:

• The IP address for the RLM

Note: Entering 0.0.0.0 for the static IP address disables IPv4 for the RLM.

• The netmask for the RLM• The IP address for the RLM gateway• The name or IP address of the mail host to use for AutoSupport (if you use the setup

command.)

4. If you have enabled IPv6 for Data ONTAP, and your RLM firmware version is 4.0 or later, theRLM supports IPv6. In this case, the RLM setup asks you whether to configure IPv6 connectionsfor the RLM. If you want to configure IPv6 connections for the RLM, enter y.

Note: You can use the rlm status command to find the RLM version information.

The RLM setup prompts you for the following IPv6 information:

• The IPv6 global addressEven if no IPv6 global address is assigned for the RLM, the link-local address is present onthe RLM. The IPv6 router-advertised address is also present if the ip.v6.ra_enable optionis set to on.

• The subnet prefix for the RLM• The IPv6 gateway for the RLM

68 | Data ONTAP 7.3 Software Setup Guide

Page 69: N Series Data ONTAP Software Setup Guide

Note: You cannot use the RLM setup to enable or disable the IPv6 router-advertised addressfor the RLM. However, when you use the ip.v6.ra_enable option to enable or disable theIPv6 router-advertised address for Data ONTAP, the same configuration applies to the RLM.

For information about enabling IPv6 for Data ONTAP or information about global, link-local,and router-advertised addresses, see the Data ONTAP Network Management Guide.

Examples for configuring the RLM

The following example shows that the RLM is configured for both IPv4 and IPv6 connections:

The Remote LAN Module (RLM) provides remote management capabilities including console redirection, logging and power control. It also extends autosupport by sending additional system event alerts. Your autosupport settings are used for sending these alerts via email over the RLM LAN interface.Would you like to configure the RLM? yWould you like to enable DHCP on the RLM LAN interface? nPlease enter the IP address for the RLM []:192.168.123.98Please enter the netmask for the RLM []:255.255.255.0Please enter the IP address for the RLM gateway []:192.168.123.1Do you want to enable IPv6 on the RLM ? yDo you want to assign IPv6 global address? yPlease enter the IPv6 address for the RLM []:fd22:8b1e:b255:204::1234Please enter the subnet prefix for the RLM []: 64Please enter the IPv6 Gateway for the RLM []:fd22:81be:b255:204::1Verifying mailhost settings for RLM use...

The following example shows that the RLM is configured to use DHCP and IPv6:

The Remote LAN Module(RLM) provides remote management capabilities including console redirection, logging and power control. It also extends autosupport by sending additional system alerts. Your autosupport settings are used for sending these alerts via email over the RLM LAN interface.Would you like to configure the RLM? yWould you like to enable DHCP on the RLM LAN interface? yDo you want to enable IPv6 on the RLM ? yDo you want to assign IPv6 global address? yPlease enter the IPv6 address for the RLM [fd22:8b1e:b255:204::1234]:Please enter the subnet prefix for the RLM [64]:

Setting up your storage system for using native disk shelves | 69

Page 70: N Series Data ONTAP Software Setup Guide

Please enter the IPv6 Gateway for the RLM [fd22:81be:b255:204::1]:Verifying mailhost settings for RLM use...

Responding to sp setup promptsIf your system includes a Service Processor, sp setup starts automatically after the setupcommand (or the cifs setup if CIFS is licensed on your system).

About this task

If you have enabled IPv6 for Data ONTAP, you have the option to configure the SP for only IPv4,for only IPv6, or for both IPv4 and IPv6. Disabling IPv6 on Data ONTAP also disables IPv6 on theSP.

Attention: If you disable both IPv4 and IPv6, and if DHCP is also not configured, the SP has nonetwork connectivity.

The firewall for IPv6 is configured to accept 10 Internet Control Message Protocol (ICMP) packetsmaximum in a one-second interval. If your system has management software that frequentlyperforms diagnostic checks, this limit can cause false positive errors to be generated. You shouldconsider increasing the software's ping interval or tuning the software's report to expect the falsepositive errors caused by the ICMP limit.

Steps

1. At the storage system prompt, enter one of the following commands:

• setup

• sp setup

If you enter setup, the sp setup command starts automatically after the setup commandfinishes running.

2. When the SP setup asks you whether to configure the SP, enter y.

3. Do one of the following when the SP setup asks you whether to enable DHCP on the SP.

• To use DHCP addressing, enter y.• To use static addressing, enter n.

Note: DHCPv6 servers are not currently supported.

4. If you do not enable DHCP for the SP, the SP setup prompts you for static IP information.Provide the following information when prompted:

• The IP address for the SP

70 | Data ONTAP 7.3 Software Setup Guide

Page 71: N Series Data ONTAP Software Setup Guide

Note: Entering 0.0.0.0 for the static IP address disables IPv4 for the SP. If you enter0.0.0.0 for the static IP address, you should enter 0.0.0.0 also for the netmask and theIP address for the SP gateway.

• The netmask for the SP• The IP address for the SP gateway• The name or IP address of the mail host to use for AutoSupport (if you use the setup

command.)

5. If you have enabled IPv6 for Data ONTAP, the SP supports IPv6. In this case, the SP setup asksyou whether to configure IPv6 connections for the SP. Do one of the following:

• To configure IPv6 connections for the SP, enter y.• To disable IPv6 connections for the SP, enter n.

6. If you choose to configure IPv6 for the SP, provide the following IPv6 information whenprompted by the SP setup:

• The IPv6 global addressEven if no IPv6 global address is assigned for the SP, the link-local address is present on theSP. The IPv6 router-advertised address is also present if the ip.v6.ra_enable option is setto on.

• The subnet prefix for the SP• The IPv6 gateway for the SP

Note: You cannot use the SP setup to enable or disable the IPv6 router-advertised address forthe SP. However, when you use the ip.v6.ra_enable option to enable or disable the IPv6router-advertised address for Data ONTAP, the same configuration applies to the SP.

For information about enabling IPv6 for Data ONTAP or information about global, link-local,and router-advertised addresses, see the Data ONTAP Network Management Guide.

7. At the storage system prompt, enter the following command to verify that the SP networkconfiguration is correct:

sp status

8. At the storage system prompt, enter the following command to verify that the SP AutoSupportfunction is working properly:

sp test autosupport

Note: The SP uses the same mail host information that Data ONTAP uses for AutoSupport.The sp test autosupport command requires that you set up the autosupport.to optionproperly.

The following message is a sample of the output Data ONTAP displays:Sending email messages via SMTP server at [email protected]. Ifautosupport.enable is on, then each email address in autosupport.toshould receive the test message shortly.

Setting up your storage system for using native disk shelves | 71

Page 72: N Series Data ONTAP Software Setup Guide

Additional steps required to set up gateways using nativedisk shelves and third-party storage

For gateways using both native disk shelves and third-party storage, you have completed theconfiguration of the native disk shelves, but you must now configure your third-party storage. Theinformation you need to connect third-party storage to Data ONTAP is given in the GatewayInstallation Requirements and Reference Guide and the Data ONTAP Storage Management Guide.

72 | Data ONTAP 7.3 Software Setup Guide

Page 73: N Series Data ONTAP Software Setup Guide

Setting up your system for using only third-partystorage

Gateways ordered without native disk shelves require some initial setup before Data ONTAP isinstalled and the system becomes operational.

Next topics

Before starting setup for using third-party storage on page 73

Providing array LUN ownership and system ID for gateways on page 73

Before starting setup for using third-party storageA number of tasks must be completed to prepare your system for connection to third-party storagearrays.

Before you start setting up your system and installing Data ONTAP software on it, you must do thefollowing:

• On the storage array, create LUNs and make them available to Data ONTAP, as described in thefollowing documentation:

• Gateway Installation Requirements and Reference Guide• Gateway Implementation Guide for your vendor

The process of making array LUNs available to Data ONTAP varies among storage arraytypes.

• Your storage array documentation• Connect your gateway and storage array as described in the Gateway Installation Requirements

and Reference Guide.

Providing array LUN ownership and system ID for gatewaysIf your gateway is using only third-party storage, you must provide information through the bootmenu and the setup program to assign array LUN ownership and identify your system on thenetwork.

Before you begin

You should complete the worksheet in the Configuration worksheet. The setup program prompts youfor this information. The worksheet includes a definition of each parameter that you need to enter toset up the system on the network.

Setting up your system for using only third-party storage | 73

Page 74: N Series Data ONTAP Software Setup Guide

About this task

You must create the LUNs on the storage array that you want this system to own. You must create atleast one array LUN. You can create more array LUNs at this stage or wait to create additional arrayLUNs after Data ONTAP is installed.

Attention: You must use LUN security to prevent gateways from accessing array LUNs owned bynon gateway hosts, and to prevent non gateway hosts from accessing array LUNs owned bygateways. Although Data ONTAP provides controls to prevent one gateway from owning an arrayLUN that is assigned to another gateway, there are no controls to prevent you from assigninggateway ownership of an array LUN owned by a non gateway host. Using the disk assigncommand to write ownership information to a LUN owned by a non gateway causes irreversibledata corruption.

Steps

1. Power on the system to load the kernel from the boot device.

The system boot process begins.

2. Interrupt the boot process by pressing Ctrl-C when you see the following message on the console:Press Ctrl-C for boot menu

3. Select Maintenance Mode.

4. To identify the LUNs on the storage array that you can configure this system to own, enter thefollowing command:

disk show -v

You see a list of all LUNs available on the storage array port to which the system is physicallyconnected.

5. To assign the LUNs on the storage array that you want this system to own, enter the followingcommand. (You must assign at least one array LUN.)

disk assign {disk_name | all | -n count} [-p pool] [-c block|zoned]

Attention: This step causes irreversible data corruption when performed on an array LUN thatis being used by or that will be used by a non gateway host.

• disk_name | all | -n count: Required option. Identifies the array LUNs assigned to thissystem.

• disk_name specifies, by LUN name, the array LUNs to be assigned. In most cases, youidentify the name of the specific array LUNs that this system is to own, in the followingform:

• all causes all array LUNs that are made available on the storage array to the gatewayneighborhood to be assigned to this system.

• -n count causes the number of unassigned array LUNs specified by count to be assignedto this system.

74 | Data ONTAP 7.3 Software Setup Guide

Page 75: N Series Data ONTAP Software Setup Guide

• -p pool

• If you are not going to be deploying SyncMirror, you do not need to enter the poolparameter. The pool parameter defaults to 0 (zero).

• For details, see the information about RAID mirroring in the Gateway InstallationRequirements and Reference Guide.

• -c block | zonedChecksum type, either block or zoned. The default value is block.When a LUN from the storage array is mapped to be used by the system, it is treated as a“raw,” unformatted disk (LUN). This unformatted array LUN needs to be formatted in eitherof two ways:

• Block checksum: Reserves 12.5 percent of the space in the array LUN for checksum.• Zoned checksum: Entries for 63 WAFL blocks are stored in a 4-KB block following each

set of 63 WAFL blocks. The 1/64 space for the zoned checksum is taken from the 10percent WAFL reserve. Therefore, the net effect is that no additional storage is lost abovethe core dump and WAFL reserve.

Note: An array LUN of type “block” is expected to be used with block checksumaggregates. An array LUN of type “zoned” is expected to be used with zoned checksumaggregates. For details about planning for checksums, see the Data ONTAP Data ProtectionOnline Backup and Recovery Guide.

ExampleIn the following example the disk assign command is used to assign storeAlun1 andstoreAlun2 to pool 0 and storeBlun1 storeBlun2 to pool1:

disk assign storeAlun1 storeAlun2 -p 0

disk assign storeBlun1 storeBlun2 -p 1

6. To see the results of assigning the LUNs, enter the following command:

disk show -v

The local system ID is shown and the array LUNs (disks) exported on the port are shown.

Review the list of array LUNs to confirm that all array LUNs you expected to be assigned to thissystem (the local system) are shown with the ID of this system.

7. To halt and then reboot the system, enter the following commands:

halt

boot

8. When you see the following message on the console, interrupt the boot process by pressing Ctrl-C:Press Ctrl-C for Boot Menu

The boot options menu appears.

Setting up your system for using only third-party storage | 75

Page 76: N Series Data ONTAP Software Setup Guide

9. Create the root volume on one of the array LUNs you displayed in the previous command, byselecting one of the volume types from the boot options menu:

• To create a traditional root volume, select:Initialize owned disks

• To create a FlexVol root volume, select:Create a flexible root volume

10. The system responds with the following message:This will erase all the data on the disks, are you sure?

Enter:

y

The storage system creates a root volume on one of the assigned array LUNs and beginsprompting for system information. When a FlexVol root volume is created, vol0 is created in anaggregate named aggr0 (the aggregate is automatically created).

For either type of volume, if you enter multiple array LUNs with the disk assign command, anarray LUN is automatically selected. The system tries to select an array LUN with a blockchecksum, if one is available, and then it selects the smallest array LUN.

11. The system displays the following prompt:Would you like to continue setup through the Web interface?

Enter:

n

Answer the prompts in the setup program, using the information that you recorded in the Configuration worksheet on page 33.

12. After the setup program is complete, install protocol and features licenses; then install DataONTAP software, as described in Installing Data ONTAP software on your system on page 77.

76 | Data ONTAP 7.3 Software Setup Guide

Page 77: N Series Data ONTAP Software Setup Guide

Installing Data ONTAP software on a gateway

This section provides you with the information you need to install Data ONTAP on a gateway.Installing Data ONTAP is required only on gateway systems that were ordered without native diskshelves. If your system was ordered with native disk shelves, Data ONTAP was already installed foryou.

Before you begin

Before you start the installation process described in this section, you should have completed theprocedures in Setting up your system for using only third-party storage on page 73.

Next topics

Data ONTAP installation stages on page 77

How you install licenses on a storage system on page 78

Obtaining Data ONTAP software images on page 79

Installing Data ONTAP software images on page 85

Managing files in the /etc/software directory on page 91

Data ONTAP installation stagesYou need to install Data ONTAP only on gateways that were ordered without native disk shelves.

Installing Data ONTAP on a gateway is a three-stage process:

1. Install licenses on the system.Before you can install the Data ONTAP software, you must install the appropriate protocollicense:

• If you are installing from a Windows client, you must install a CIFS license.• If you are installing from a UNIX client, you must install an NFS license.• If you are installing from an HTTP server, no license is required.

2. Obtain the installation image.

3. Install the software.

Installing Data ONTAP software on a gateway | 77

Page 78: N Series Data ONTAP Software Setup Guide

How you install licenses on a storage systemYour storage system requires a license for the gateway software and may require protocol licenses tocomplete the installation process. You can install other licenses such as licenses for SyncMirror,SnapMover, or HTTP Server, before or after you install Data ONTAP software.

The procedure you use to install licenses differs slightly, depending on whether you are installinglicenses on a single system or on an active/active configuration.

Next topics

Installing licenses on a single system on page 78

Installing licenses on an active/active configuration on page 79

Installing licenses on a single systemTo install licenses on a single system, you use the license add command along with the licensecode you were given when you purchased the license.

Before you begin

Before installing licenses, you should have completed the procedures in Setting up your system forusing only third-party storage on page 73.

Steps

1. Enter the following command on the console:

license add code ...

code is the license code that you were given when you purchased the license for the service orprotocol.

ExampleIn this example, the license code for CIFS is ABCDEFG and the license code for the gateway isgateway:

license add ABCDEFG gateway

The storage system acknowledges each license, in a manner similar to that shown in the followingexample:

A cifs license has been installed. Use “cifs setup” to configure cifs. Run cifs setup to enable cifs.A gateway license has been installed.gateway storage will be enabled after reboot.

2. Reboot the storage system using the following command:

78 | Data ONTAP 7.3 Software Setup Guide

Page 79: N Series Data ONTAP Software Setup Guide

reboot

Note: If you are installing a SyncMirror license, you do not need to reboot.

Installing licenses on an active/active configurationTo install licenses on an active/active configuration, you use the license add command on bothstorage system consoles.

Before you begin

Before installing licenses, you should have completed the procedures in Setting up your system forusing only third-party storage on page 73.

Steps

1. Enter the active/active configuration license code using the following command on both storagesystem consoles:

license add code

code is the license code.

2. Reboot both storage systems using the following command:

reboot

3. Enable the active/active configuration on each storage system by entering the following commandon each console:

cf enable

4. Ensure that the active/active configuration is enabled by entering the following command on eachconsole:

cf status

When enabled, each system responds with a message similar to the following: Cluster enabled, gateway 2 is up

5. Repeat Step 1 for each licensed product installed on the active/active configuration.

6. Reboot both storage systems in the active/active configuration.

Note: If you are installing a SyncMirror license, you do not need to reboot the systems.

Obtaining Data ONTAP software imagesYou must copy a software image from the IBM NAS support site to your storage system using UNIXor Windows client connections. Alternatively, you can copy software images to an HTTP server onyour network and then storage systems can access the images using the software command.

To upgrade the storage system to the latest release of Data ONTAP, you need access to softwareimages and the latest firmware versions. Software images, firmware version information, and the

Installing Data ONTAP software on a gateway | 79

Page 80: N Series Data ONTAP Software Setup Guide

latest firmware for your storage system model are available on the IBM NAS support site. Note thefollowing important information:

• Software images are specific to storage system models.Be sure to obtain the correct image for your system.

• Software images include the latest version of system firmware that was available when a givenversion of Data ONTAP was released.

Next topics

Obtaining images for HTTP servers on page 80

Obtaining images for UNIX clients on page 81

Obtaining images for Windows clients on page 83

Obtaining images for HTTP serversIf you have an HTTP server that is accessible to your storage system, you can copy Data ONTAPsoftware images to the HTTP server and use the software command to download and install DataONTAP software images to your storage system.

Note: You can also use HTTPS connections when SecureAdmin is installed and enabled on thestorage system.

When you use an HTTP server to provide Data ONTAP software images, you do not have to mountthe storage system to a UNIX administration host or map a drive to the storage system usingWindows to perform the installation.

You can copy the Data ONTAP system files to both single systems and storage systems in an active/active configuration.

For more information, see the software (1) man page.

Next topics

Copying the software image to the HTTP server on page 80

Copying software images from the HTTP server without installing the images on page 81

Copying the software image to the HTTP server

You must copy the software image file to the HTTP server. This task prepares the HTTP server toserve software images to storage systems in your environment.

Step

1. Copy the software image (for example, 73_setup_i.exe) from the IBM NAS support site oranother system to the directory on the HTTP server from which the file will be served.

80 | Data ONTAP 7.3 Software Setup Guide

Page 81: N Series Data ONTAP Software Setup Guide

Copying software images from the HTTP server without installing the images

You can copy software images to your storage system without immediately installing them. Youmight do this, for instance, if you want to perform the installation at a later time.

Step

1. Enter the following command from the storage system console:

software get url -f filename

url is the HTTP location from which you want to copy the Data ONTAP software images.

Use the following URL syntax if you need to specify a user name, password, host, and port toaccess files on the HTTP server using Basic Access Authentication (RFC2617):

http://username:password@host:port/path

Use the -f flag to overwrite an existing software file of the same name in the storage system's /etc/software directory. If a file of the same name exists and you do not use the -f flag, thedownload will fail and you will be prompted to use -f.

filename is the file name you specify for the software file being downloaded to your storagesystem. If no destination file name is specified, Data ONTAP uses the file name listed in the URLfrom which you are downloading and places the copy in the /etc/software directory on thestorage system.

ExampleIn the following example, the software get command uses a new destination file name:

software get http://www.example.com/downloads/pc_elf/73_setup_i.exe73_mailboxes_i.exe

You see a message similar to the following:

software: copying to /etc/software/73_mailboxes_i.exesoftware: 100% file read from location.software: /etc/software/73_mailboxes_i.exe has been copied.

Obtaining images for UNIX clientsIf you are using a UNIX client to copy a Data ONTAP software image to your storage system, youneed access to both the storage system's console and the system's administration host. If theadministration host does not have a Web connection, you must also have access to a client systemthat can reach the IBM NAS support site.

Next topics

Mounting the storage system on your client on page 82

Obtaining software images on page 82

Installing Data ONTAP software on a gateway | 81

Page 82: N Series Data ONTAP Software Setup Guide

Mounting the storage system on your client

Before you copy a software image to your storage system, you must mount the system on your UNIXadministration host.

Steps

1. As root user, mount the storage system’s root file system to the client’s /mnt directory, using thefollowing command:

mount system:/vol/vol0 /mnt

system is the name of the storage system.

/mnt is the directory on the client where you want to mount the storage system’s root file system.

2. Change to the /mnt directory using the following command on your UNIX client console:

cd /mnt

/mnt is the directory on the client where you mounted the storage system’s root file system.

3. To acquire Data ONTAP files, download the Data ONTAP files using a Web browser from theIBM NAS support site.

Obtaining software images

You can use a Web browser to copy the software image from the IBM NAS support site to a UNIXclient.

About this task

You can copy the software image directly to your administration host. If your administration hostdoes not have Web access, you can copy the software image to portable storage media attached to adifferent client, then copy the image from portable storage to the administration host.

Note: Be sure to save the .exe image to your system; do not run it as an executable file.

Steps

1. Use a Web browser to log in to the IBM NAS support site.

2. Click Data ONTAP.

3. Click the Download tab.

4. After you have chosen the software image that corresponds to your platform, complete one of thefollowing actions, depending on your Web environment.

82 | Data ONTAP 7.3 Software Setup Guide

Page 83: N Series Data ONTAP Software Setup Guide

If you are connecting to theIBM NAS support site from...

Then...

An administration host Save the image to the .../etc/software directory on themountpoint that you chose when you mounted the storage system on yourclient.

Another UNIX client a. Save the image to portable storage media.

b. Connect the portable storage media to your administration host.

c. Copy the image to the .../etc/software directory on themountpoint that you chose when you mounted the storage system onyour client.

5. Continue with the installation procedures.

Related concepts

Installing Data ONTAP software images on page 85

Obtaining images for Windows clientsIf you are using a Windows client to copy a Data ONTAP software image to your storage system,you need access to both the storage system's console and the system's administration host. If theadministration host does not have a Web connection, you must also have access to a client systemthat can reach the IBM NAS support site.

Next topics

Mapping the storage system to a drive on page 83

Obtaining software images on page 84

Mapping the storage system to a drive

Before you copy a software image to your storage system, you must map the root directory of thesystem to your Windows administration host.

Before you begin

You should make sure that the CIFS service is running and that the Administrator user is defined inCIFS as having authority to access the C$ directory.

Steps

1. Log in to your client as Administrator or log in using an account that has full control on thestorage system C$ directory.

2. Map a drive to the C$ directory of your storage system.

Installing Data ONTAP software on a gateway | 83

Page 84: N Series Data ONTAP Software Setup Guide

Note: On some computers, firewall software might not permit you to map a drive to the C$directory of a storage system. To complete this procedure, disable the firewall until you nolonger need access to the storage system through your laptop.

3. Copy the software image from the IBM NAS support site.

Obtaining software images

You can use a Web browser to copy the software image from the IBM NAS support site to aWindows client.

About this task

You can copy the software image directly to your administration host. If your administration hostdoes not have Web access, you can copy the software image to portable storage media attached to adifferent client, then copy the image from portable storage to the administration host.

Note: Be sure to save the .exe image to your storage system; do not run it as an executable file.

Steps

1. Use a Web browser to log in to the IBM NAS support site.

2. Click Data ONTAP from the Current N series NAS/iSCSI product list.

3. Click the Download tab, and then click Downloadable Files.

4. Choose Windows from the Platform/Operating system drop-down list.

5. After you have chosen the software image that corresponds to your platform, complete one of thefollowing actions, depending on your Web environment.

If you are connecting to theIBM NAS support sitefrom...

Then...

An administration host Save the image to the \etc\software directory on the mountpointthat you chose previously, when you mounted the storage system on yourclient.

Another Windows client a. Save the image to portable storage media.

b. Connect the portable storage media to your administration host.

c. Copy the image to the \etc\software directory on themountpoint that you chose previously, when you mounted the storagesystem on your client.

6. Continue with the installation procedures.

84 | Data ONTAP 7.3 Software Setup Guide

Page 85: N Series Data ONTAP Software Setup Guide

Related concepts

Installing Data ONTAP software images on page 85

Installing Data ONTAP software imagesYou should use the software update command to extract and install the system files on a storagesystem.

You can use the software update command to install a software image you have already copiedto your storage system, or to copy and install the image from an HTTP server.

You must know the location of and have access to the software image. The software updatecommand requires one of the following as an argument:

• The name of the software image you copied to the /etc/software directory• The URL of the HTTP server that you configured to serve software images

The software update command allows you to perform several operations at one time. Forexample, if you use an HTTP server to distribute software images, you can copy an image from theHTTP server, extract and install the system files, download the files to the boot device, and rebootyour system with one command.

For more information about the software update command and its options, see the software(1)man page.

Next topics

Installing software images from the /etc/software directory on page 85

Installing software images from an HTTP server on page 88

Installing software images from the /etc/software directoryTo complete this procedure, the new software image must be present in the /etc/softwaredirectory on your storage system.

Step

1. From the storage system prompt, enter the following command:

software update file options

• file is the name of the software image you copied to the /etc/software directory.• options is one or more of the following:

• The -d option prevents the download command from being run automatically after thesystem files are installed.

• The -f option overwrites the existing image in the /etc/software directory.

Installing Data ONTAP software on a gateway | 85

Page 86: N Series Data ONTAP Software Setup Guide

• The -r option prevents the system from rebooting automatically after the downloadcommand has finished (default).

• The -R option causes the system to reboot automatically after the download commandhas finished.

86 | Data ONTAP 7.3 Software Setup Guide

Page 87: N Series Data ONTAP Software Setup Guide

Example

If you are runningData ONTAP...

And you want to... Then you can enter...

7.3.5 or later Install the newsystem files fromthe /etc/software directory

software updatemy_73_setup_i.exe-d

Download the newsystem files to theboot deviceimmediately afterinstalling them

software updatemy_73_setup_i.exe

Copy and install theimage from yourHTTP server

software updatehttp://www.example.com/downloads/pc_elf/my_73_setup_i.exe

Copy from yourHTTP server andoverwrite an existingimage

software updatehttp://www.example.com/downloads/pc_elf/my_73_setup_i.exe-f

7.3.4 or earlier Install the new systemfiles from the /etc/software directory

software updatemy_73_setup_i.exe -d -r

Download the newsystem files to the bootdevice immediatelyafter installing them

software updatemy_73_setup_i.exe-r

Copy and install theimage from yourHTTP server

software updatehttp://www.example.com/downloads/pc_elf/my_73_setup_i.exe

Copy from your HTTPserver and overwritean existing image

software updatehttp://www.example.com/downloads/pc_elf/my_73_setup_i.exe-f

Installing Data ONTAP software on a gateway | 87

Page 88: N Series Data ONTAP Software Setup Guide

When you use the software update command without the options, a message similar to thefollowing appears on your storage system console:

software: You can cancel this operation by hitting Ctrl-C in the next 6 seconds.software: Depending on system load, it might take many minutessoftware: to complete this operation. Until it finishes, you willsoftware: not be able to use the console.software: copying to <filename>software: 100% file read from location.software: /etc/software/<filename> has been copied.software: installing software, this could take a few minutes...software: Data ONTAP Package Manager Verifier 1software: Validating metadata entries in /etc/boot/NPM_METADATA.txtsoftware: Checking sha1 checksum of file checksum file: /etc/boot/NPM_FCSUM-pc.sha1.ascsoftware: Checking sha1 file checksums in /etc/boot/NPM_FCSUM-pc.sha1.ascsoftware: installation of <filename> completed.Mon Oct 2 13:26:17 PDT [filer: rc:info]: software: installation of <filename> completed.

software: Reminder: You might need to upgrade Volume SnapMirror destinationsoftware: filers associated with this filer. Volume SnapMirror can not mirrorsoftware: if the version of ONTAP on the source filer is newer than that on software: the destination filer.Mon Oct 2 13:26:17 PDT [filer: download.request:notice]

After you finish

Complete the installation by downloading to active/active configurations or single systems.

Installing software images from an HTTP serverTo complete this procedure, you must know the URL of an HTTP server in your environment that isconfigured to serve software images.

Step

1. From the storage system prompt, enter the following command:

software update url options

• url is the URL of the HTTP server and subdirectory.• options is one or more of the following:

• The -d option prevents the download command from being run automatically after thesystem files are installed.

• The -f option overwrites the existing image in the /etc/software directory.

88 | Data ONTAP 7.3 Software Setup Guide

Page 89: N Series Data ONTAP Software Setup Guide

• The -r option prevents the system from rebooting automatically after the downloadcommand has finished (default).

• The -R option causes the system to reboot automatically after the download commandhas finished.

Example

If you are running DataONTAP...

And you want to... Then you can enter...

7.3.5 or later Copy and install the imagefrom your HTTP server

software update http://www.example.com/downloads/pc_elf/my_73_setup_i.exe -d

Copy from your HTTPserver and overwrite anexisting image

software update http://www.example.com/downloads/pc_elf/my_73_setup_i.exe -d -f

Copy and install the imagefrom your HTTP server,then download the newsystem files to the bootdevice immediately afterinstalling them

software update http://www.example.com/downloads/pc_elf/my_73_setup_i.exe

Copy and install the imagefrom your HTTP server to asingle system, thendownload the new systemfiles and reboot immediately

software update http://www.example.com/downloads/pc_elf/my_73_setup_i.exe -R

Installing Data ONTAP software on a gateway | 89

Page 90: N Series Data ONTAP Software Setup Guide

If you are running DataONTAP...

And you want to... Then you can enter...

7.3.4 or earlier Copy and install the imagefrom your HTTP server

software update http://www.example.com/downloads/pc_elf/my_73_setup_i.exe -d -r

Copy from your HTTPserver and overwrite anexisting image

software update http://www.example.com/downloads/pc_elf/my_73_setup_i.exe -d -r-f

Copy and install the imagefrom your HTTP server,then download the newsystem files to the bootdevice immediately afterinstalling them

software update http://www.example.com/downloads/pc_elf/my_73_setup_i.exe -r

Copy and install the imagefrom your HTTP server to asingle system, thendownload the new systemfiles and reboot immediately

software update http://www.example.com/downloads/pc_elf/my_73_setup_i.exe

When you use the software update command without the options, a message similar to thefollowing appears on your storage system console:

software: You can cancel this operation by hitting Ctrl-C in the next 6 seconds.software: Depending on system load, it might take many minutessoftware: to complete this operation. Until it finishes, you willsoftware: not be able to use the console.software: copying to <filename>software: 100% file read from location.software: /etc/software/<filename> has been copied.software: installing software, this could take a few minutes...software: Data ONTAP Package Manager Verifier 1software: Validating metadata entries in /etc/boot/NPM_METADATA.txtsoftware: Checking sha1 checksum of file checksum file: /etc/boot/NPM_FCSUM-pc.sha1.ascsoftware: Checking sha1 file checksums in /etc/boot/NPM_FCSUM-pc.sha1.ascsoftware: installation of <filename> completed.Mon Oct 2 13:26:17 PDT [filer: rc:info]: software: installation of <filename> completed.

software: Reminder: You might need to upgrade Volume SnapMirror destinationsoftware: filers associated with this filer. Volume SnapMirror can not

90 | Data ONTAP 7.3 Software Setup Guide

Page 91: N Series Data ONTAP Software Setup Guide

mirrorsoftware: if the version of ONTAP on the source filer is newer than that on software: the destination filer.Mon Oct 2 13:26:17 PDT [filer: download.request:notice]

After you finish

Complete the installation by downloading to active/active configurations or single systems.

Managing files in the /etc/software directoryAfter you have copied Data ONTAP system files to the /etc/software directory on your storagesystem, you can manage them from the storage system console with the software command.

If you want to... Then use the following command...

List the contents of the /etc/softwaredirectory

software list

Delete files from the /etc/software directory software delete

For more information, see the software(1) command man page.

Installing Data ONTAP software on a gateway | 91

Page 92: N Series Data ONTAP Software Setup Guide
Page 93: N Series Data ONTAP Software Setup Guide

Verifying software setup

As soon as hardware and software setup is complete, you should verify network connections,licensed functionality, and other relevant configurations in your environment.

Next topics

Verifying network connectivity on page 93

Verifying host-name resolution on page 94

Verifying that the storage system is available on page 96

Verifying licensing on page 97

Preparing NFS clients to access the storage system on page 97

Preparing CIFS clients to access the storage system on page 99

Verifying the configuration for active/active storage systems on page 99

Verifying BMC connections on page 100

Verifying RLM connections on page 101

Verifying the existence of two paths to an array LUN in a gateway on page 103

Verifying path failover for array LUNs in a gateway on page 104

Verifying network connectivityYou use the ping command to verify that your clients can connect to the IP addresses youconfigured on the storage system during setup.

About this task

You must perform these tasks from a network client system.

Note: Beginning with Data ONTAP 7.3.3, the ping command can take an IPv6 address as anargument; it is no longer necessary to enter ping6 IPv6_address.

For more information, see the Data ONTAP Network Management Guide.

Steps

1. To verify network connectivity to an IP address, enter the following command:

ping IP_address

IP_address is the IP address that the storage system assigned to that interface during setup.

Verifying software setup | 93

Page 94: N Series Data ONTAP Software Setup Guide

Example

The following command tests the IPv6 connections for a storage system with an interface namede0a installed at 2001:0DB8:85A3:0:0:8A2E:0370:99:

ping6 2001:0DB8:85A3:0:0:8A2E:0370:99

The following command tests the IPv4 network connections for a storage system with aninterface named e0a installed at 192.0.2.66:

ping 192.0.2.66

2. Repeat the test once for each interface that is installed in the storage system.

Result

You should be able to reach your new storage system from clients on your network. If you cannot,use the recommended troubleshooting procedures.

Troubleshooting connections to new network interfacesThere are several ways to identify a problem when new network interfaces do not respond to a pingcommand.

Steps

1. Check to make sure that the interface is securely attached to the network.

2. Check to make sure that the media type is set up correctly if the interface is using a multiportEthernet card with different port speeds.

3. Check to make sure that the routers function properly with correct routing information if theping command is issued from a network not directly attached to the interface.

4. If you received a response from the IP address ping but not the host-name ping, check to seewhether there is a problem with host-name resolution.

Related tasks

Verifying host-name resolution on page 94

Verifying host-name resolutionYou should ensure that host names you configured during setup are resolved into IP addresses.

About this task

When you ran setup, the storage system generated a host name for each interface by appending thename of the interface to the storage system host name. You need to make sure that theseautomatically generated host names are resolved into IP addresses.

94 | Data ONTAP 7.3 Software Setup Guide

Page 95: N Series Data ONTAP Software Setup Guide

For example, the interface name for the first interface on a storage system named "toaster" might betoaster-e0a; the second interface might be toaster-e0b.

For more information about host-name resolution, see your Data ONTAP Network ManagementGuide.

Steps

1. Take one of the following actions from a client system:

If you use... Then add an entry in...

DNS or NIS for nameresolution

Your DNS or NIS databases for each of the storage system interfaces.

The following example shows how the entries might look for a storagesystem with four interfaces:

192.16.3.145 toaster-e0a 192.16.3.146 toaster-e0b 192.16.3.147 toaster-f0 192.16.3.148 toaster-a5

/etc/hosts files forname resolution

Each host's /etc/hosts file for each of the storage system interfaces.

2. To verify host-name resolution for a network interface, enter the following command:

ping hostname-interface

hostname is the host name that you assigned to the storage system when you ran setup.

interface is one of the interface names that the storage system assigned when you ran setup.

Example

The following command tests the network connections for a storage system that has the hostname "toaster" with an interface named e0a installed.

ping toaster-e0a

3. Repeat the test once for each interface that is installed in the storage system.

Result

If you received a response from the IP-address ping but not the host-name ping, there might be aproblem with name resolution.

Verifying software setup | 95

Page 96: N Series Data ONTAP Software Setup Guide

Verifying that the storage system is availableYou can use the exportfs command to verify that the root path and root directory are available toclients.

About this task

After setup is complete, the storage system is online, and the following entities should exist on thestorage system:

• /vol/vol0 (a virtual root path)• /vol/vol0/home (a directory)

Note that /vol is not a directory–it is a special virtual root path under which the storage systemmounts its volumes. You cannot mount /vol to view all the volumes on the storage system; you mustmount each storage system volume separately. NFS and CIFS protocols provide the following accesscharacteristics for the /vol virtual root path:

• For NFS /vol/vol0 is exported to the administration host for root access; /vol0/home is exported to theadministration host for root access and to all clients for general access.

• For CIFS By default, /vol/vol0 is shared as C$ and /vol/vol0/etc/ is shared as $ETC. These two shares arecreated with "Full Control" given to the Builtin Administrators group and with no access given toany other users or groups. By default, the Builtin Administrators group members are the localadministrator account, the Domain Administrator's group (if the storage system belongs to adomain), and any user or group that you configured with Administrative access during CIFSsetup. The /vol/vol0/home directory is shared as HOME with "Full Control" access granted to thegroup Everyone.

Step

1. To verify that the /vol/vol0 path and /vol/vol0/home directory entities exist on your storagesystem, enter the following command at the storage system command line:

exportfs

You should see a listing that includes lines similar to the following:

/vol/vol0 -sec=sys,rw=admin_host,root=admin_host,nosuid/vol/vol0/home -sec=sys,rw,root=admin_host,nosuid

96 | Data ONTAP 7.3 Software Setup Guide

Page 97: N Series Data ONTAP Software Setup Guide

Verifying licensingYou can use the license command at the storage system command line to verify that theappropriate protocol and service licenses are installed on your system, or to configure additionallicenses.

About this task

For more information about storage system licensing, see your Data ONTAP System AdministrationGuide and the license(1) man page.

Step

1. Enter the appropriate license command to manage your licenses.

If you want to... Enter this command at the storage system prompt...

View existing licenses license

Result: You see a list of licenses and license codes.

Add a license license add license_code

Result: The new protocol or service is enabled and added to the list of licenses.

Remove a license license delete service

Result: The protocol or service is disabled and removed from the list of licenses.

Preparing NFS clients to access the storage systemTo make storage system data available to NFS clients, you need to export the storage system's filesystem. You must also mount the file system on your NFS clients.

For more information about NFS configuration, see your Data ONTAP File Access and ProtocolsManagement Guide and your NFS client documentation.

Exporting file systems to NFS clientsBefore NFS clients can mount file systems, you need to export those file systems by adding them tothe storage system's /etc/exports file.

About this task

Security styles of file systems–UNIX, NTFS, and Mixed–are all available for exporting and can bemounted by NFS clients. However, for accessing a volume with NTFS effective security style (NTFSvolume or mixed volume with NTFS effective security style), file access is granted based on NTFSpermissions. To properly ascertain file permissions, UNIX user names are mapped to corresponding

Verifying software setup | 97

Page 98: N Series Data ONTAP Software Setup Guide

Windows user names, and access is granted based on NTFS permissions granted to the mappedWindows user.

Steps

1. Determine valid path names for directories by entering the following command at the storagesystem prompt:

qtree status

ExampleThe following display shows sample output from the qtree status command:

Volume Tree Style Oplocks Status ------ ---- ----- ------- -------vol0 home unix enabled normalvol1snap qtree1 unix enabled normalvol2eng team1 mixed enabled normalvol2mkt nt ntfs enabled normal

2. From the qtree command output, convert the first two entries into valid path names. To do so,use this format:

/Volume/Tree

Example

/vol0/home/vol1snap/qtree1/vol2eng/team1

3. Use a text editor from an NFS client to open the /etc/exports file on the storage system.

4. Add the storage system directories to the /etc/exports file.

Example

/vol/vol0/home -sec=sys, rw, root=admin_host/vol/vol1snap/qtree1 -sec=sys, rw, root=admin_host/vol/vol2eng/team1 -sec=sys, rw=10.0.0.0/24:172.17.0.0/16, root=admin_host/vol/vol2mkt/nt -sec=sys, rw=netgroup1:netgroup2, root=admin_host:10.0.0.100

For information about specifying entries and access permissions in the /etc/exports file, see thechapter about file access using NFS in your Data ONTAP File Access and Protocols ManagementGuide.

5. Save the file and exit the text editor.

6. To make your changes to the /etc/exports file effective immediately, issue the exportfscommand with the reload option:

98 | Data ONTAP 7.3 Software Setup Guide

Page 99: N Series Data ONTAP Software Setup Guide

exportfs -r

Preparing CIFS clients to access the storage systemIf you are in an Active Directory domain, you must ensure that DNS is correctly configured to ensureCIFS client access.

Once setup is complete, the storage system establishes CIFS client connectivity by automaticallyregistering with the master browser. If cross-subnet browsing is configured correctly, the storagesystem is now visible to all CIFS clients. For more information about cross-subnet browsing, seeMicrosoft networking documentation.

Note: Although CIFS visibility has been established, you need to configure shares with CIFSaccess permissions before any storage system data can become accessible to CIFS clients. Forinformation about how to make a test share available to CIFS clients, see the Data ONTAP FileAccess and Protocols Management Guide.

You will also need to provide information to Windows client users about how to access data on thestorage system for their particular Windows version.

Creating a storage system DNS "A" record for CIFS client accessIn Active Directory domains, you must create a storage system DNS "A" record on the DNS serverbefore providing access to CIFS clients.

About this task

The storage system's DNS "A" record can be created manually or registered dynamically.

Step

1. To enable dynamic DNS, set one of the following options:

dns.update.enable on

dns.update.enable secure

Use secure if your DNS supports secure updates.

To disable dynamic DNS, set the dns.update.enable option to off.

Verifying the configuration for active/active storage systemsBefore placing your active/active pair online, it is recommended that you check your configurationusing the command-line interface.

When you configure active/active systems, the following configuration information needs to be thesame on both systems:

Verifying software setup | 99

Page 100: N Series Data ONTAP Software Setup Guide

• Parameters• Network interfaces• Configuration files• Licenses and option settings

Note: The values for domain controllers and WINS servers no longer need to be identical on bothstorage systems in an active/active configuration. You can have each storage system exist in adifferent domain or a different workgroup, or both. However, if you have a multiprotocolenvironment and use UID-to-SID mapping, the UNIX security information must be compatiblebetween the two domains. For example, if you have a UID of 119, it must map to the sameWindows account for both storage systems.

For more information about verifying your configuration and managing storage systems in an active/active configuration, see your Data ONTAP Active/Active Configuration Guide.

Verifying BMC connectionsUse this procedure to verify that the Baseboard Management Controller (BMC) is set up correctlyand connected to the network.

About this task

The BMC network interface is not used for serving data, so it does not show up in the output for theifconfig command.

For more information about using the BMC to manage remote storage systems, see your DataONTAP System Administration Guide.

Steps

1. To verify that AutoSupport is enabled and AutoSupport options are valid, enter the followingcommand:

options autosupport

The AutoSupport options should be set as follows:

autosupport.enable on autosupport.support.enable on autosupport.mailhost name or IP address of mailhostautosupport.content complete

Note: The BMC does not rely on the storage system's autosupport.support.transportoption to send notifications. The BMC uses the Simple Mail Transport Protocol (SMTP).

2. Enter the following command to verify that the BMC's network configuration is correct or todisplay the MAC address of the BMC:

100 | Data ONTAP 7.3 Software Setup Guide

Page 101: N Series Data ONTAP Software Setup Guide

bmc status

Example

If you used the static IP address in Step 1, the following output is displayed:

Baseboard Management Controller: Firmware Version: 1.0 IPMI version: 2.0 DHCP: off BMC MAC address: ff:ff:ff:ff:ff:ff IP address: 10.98.148.61 IP mask: 255.255.255.0 Gateway IP address: 10.98.148.1 BMC ARP interval: 10 seconds BMC has (1) user: naroot ASUP enabled: on ASUP mailhost: [email protected] ASUP from: [email protected] ASUP recipients: [email protected] Uptime: 0 Days, 04:47:45

3. Enter the following command to verify that the BMC AutoSupport function is working properly:

bmc test autosupport

Note: The BMC uses the same mail host information that Data ONTAP uses for AutoSupport.You must ensure that the autosupport.to option has been set properly before issuing thiscommand.

You have successfully set up the BMC AutoSupport function when the following output isdisplayed:Please check ASUP message on your recipient mailbox

Verifying RLM connectionsYou can use this procedure to verify that the Remote LAN Module (RLM) is set up correctly andconnected to the network.

Before you begin

It is best to use the RLM with AutoSupport. Data ONTAP automatically sends the AutoSupportconfiguration to the RLM, allowing the RLM to send alerts and notifications through an AutoSupportmessage. AutoSupport is enabled by default when you configure your storage system for the firsttime.

About this task

The RLM network interface is not used for serving data, so it does not show up in the output for theifconfig command.

Verifying software setup | 101

Page 102: N Series Data ONTAP Software Setup Guide

For more information about AutoSupport and about using the RLM to manage remote storagesystems, see your Data ONTAP System Administration Guide.

Steps

1. To verify that AutoSupport is enabled and AutoSupport options are valid, enter the followingcommand:

options autosupport

The AutoSupport options should be set as follows:

autosupport.enable on autosupport.support.enable on autosupport.mailhost name or IP address of mailhostautosupport.to name or email address of alert recipients

2. Enter the following command to verify the configuration of the RLM interface:

rlm status

Note: It might take a few minutes for the new network settings for the RLM to take effect.

3. Enter the following command to verify that the RLM AutoSupport function is working properly:

rlm test autosupport

Note: The RLM uses the same mail host information that Data ONTAP uses for AutoSupport.You must ensure that the autosupport.to option is set properly before issuing thiscommand.

The following message is a sample of the output Data ONTAP displays:

Sending email messages via SMTP server [email protected]. If autosupport.enable is on, then each email address in autosupport.to should receive the test message shortly.

The RLM should send e-mail within a few minutes. If the test fails, you should verify storagesystem connectivity and check whether the mail host and recipients are valid.

Example for displaying configuration information

The following example displays the RLM status and configuration information:

storage-system> rlm status Remote LAN Module Status: Online Part Number: 110-00030 Revision: A0 Serial Number: 123456 Firmware Version: 4.0 Mgmt MAC Address: 00:A0:98:01:7D:5B Ethernet Link: up, 100Mb, full duplex, auto-neg complete Using DHCP: no

102 | Data ONTAP 7.3 Software Setup Guide

Page 103: N Series Data ONTAP Software Setup Guide

IPv4 configuration: IP Address: 192.168.123.98 Netmask: 255.255.255.0 Gateway: 192.168.123.1 IPv6 configuration: Global IP: fd22:8b1e:b255:204::1234 Prefix Length: 64 Gateway: fd22:81be:b255:204::1 Router Assigned IP: fd22:8b1e:b255:204:2a0:98ff:fe01:7d5b Prefix Length: 64 Link Local IP: fe80::2a0:98ff:fe00:7d1b Prefix Length: 64

Verifying the existence of two paths to an array LUN in agateway

Data ONTAP automatically maps each storage system port to a secondary path on the storage array,if the primary path fails. You want to ensure that there are two paths to each array LUN so that thestorage system can continue to work when running on a single path.

Verifying the existence of two paths with the storage show disk commandYou should verify that your gateway is configured with two paths to a LUN, providing a secondarypath should the primary path fail or be taken offline.

Steps

1. Enter the following command to show the primary and secondary paths to LUNs:

storage show disk -p all

The system displays information similar to the following:

PRIMARY PORT SECONDARY PORT SHELF BAY ADAPTER-------------------- ---- ------------------------- ---- ---vnmc4500s32:4.127L1 - vnmc4500s33:19.127L1 - - - 0avnmc4500s32:4.127L12 - vnmc4500s33:19.127L12 - - - 0avnmc4500s33:19.127L2 - vnmc4500s32:4.127L2 - - - 0cvnmc4500s33:19.127L13 - vnmc4500s32:4.127L13 - - - 0c

Note: When you use the all variable, adapters are displayed, but unassigned LUNs are notvisible.

2. Determine whether a primary path and a secondary path to the array LUNs are shown.

If you do not see a primary and secondary path, check zoning, host group configuration, andcabling.

Note: Do not continue with testing until you see two paths.

3. Look at the adapters shown to see whether all paths are on a single adapter.

Verifying software setup | 103

Page 104: N Series Data ONTAP Software Setup Guide

If you see both paths through one port (for example, both paths through the 0c port), this is anindication that the back-end zoning is redundantly crossed. This is not a supported configuration.

Note: Data ONTAP changes the path to array LUNs, as necessary, for load balancing.Therefore, the primary and secondary paths for a given array LUN can change when thestorage show disk command is issued at different times.

Verifying path failover for array LUNs in a gatewayYou want to demonstrate that the gateway continues to work when running with a single path, forexample, when a switch or array port is taken offline. You can test path failover by physicallyremoving fibre cables or taking ports offline using Data ONTAP commands.

The procedure you use to test path failover differs slightly, depending on whether you are testing astand-alone system or an active/active configuration.

Next topics

Verifying path failover for array LUNs in a stand-alone system on page 104

Verifying path failover for array LUNs in an active/active configuration on page 105

Verifying path failover for array LUNs in a stand-alone systemUse this procedure to demonstrate that a stand-alone gateway continues to operate on a single path.

Steps

1. Set port 0a offline using the following command:

fcadmin offline 0a

2. Show the number of disks seen on each adapter using the following command:

sysconfig

No disks will be assigned to adapter 0a.

3. Show the primary and secondary paths using the following command:

storage show disk -p

4. Return port 0a to online:

fcadmin online 0a

104 | Data ONTAP 7.3 Software Setup Guide

Page 105: N Series Data ONTAP Software Setup Guide

Verifying path failover for array LUNs in an active/active configurationUse this procedure to demonstrate that cluster failover and then path failover occur in an active/activeconfiguration of a gateway, so that the system can to continue to operate on a single path.

Steps

1. On the local node, enter the following command to set port 0a offline (assuming the redundantport pair is 0a and 0c):

fcadmin offline 0a

2. Verify that only one path is available on the port pair:

storage show disk -p

3. Enter the following command to initiate cluster takeover:

cf takeover

4. On the partner node, enter the following command:

cf giveback

5. After the partner node is back online, repeat Steps 1, 2, and 3 on the partner node.

Verifying software setup | 105

Page 106: N Series Data ONTAP Software Setup Guide
Page 107: N Series Data ONTAP Software Setup Guide

Where to go from here

Product documentation for the storage system is available online and in printed format.

Documentation is available on the IBM NAS support site. You can also order printed copies fromthis Web site. See the Release Notes for information about this Data ONTAP release.

For information about... Go to the IBM NAS support site for the...

New features, enhancements, known issues, andlate-breaking news for your version of DataONTAP software

Data ONTAP Release Notes for your version ofData ONTAP

Setting up and verifying software configuration Data ONTAP Software Setup Guide

Managing all aspects of your system Documentation for your version of DataONTAP.

Cabling, configuring, and disk ownership Data ONTAP Active/Active ConfigurationGuide

Data ONTAP System Administration Guide

Data ONTAP Data Protection Online Backupand Recovery Guide

Data ONTAP Storage Management Guide

Setting up and managing network configurationsof storage systems

Data ONTAP Network Management Guide

Configuring and managing the FC protocol, andcreating and managing LUNs and initiatorgroups with the FC service

Data ONTAP Block Access Management Guidefor iSCSI and FC

The most current information about your systemhardware

Appropriate hardware and service guide andInteroperability Matrix on the IBM NASSupport site

Hardware configuration options available foryour system

Appropriate hardware and service guide

Troubleshooting your system Platform Monitoring Guide

Testing field-replaceable units and diagnosingand correcting system hardware problems

Diagnostics Guide

Configuring Remote Management after initialsetup

Data ONTAP System Administration Guide

Where to go from here | 107

Page 108: N Series Data ONTAP Software Setup Guide

For information about... Go to the IBM NAS support site for the...

Managing your disk shelves EXN1000, EXN2000, EXN3000, EXN3500or EXN4000 Hardware and Service Guide

108 | Data ONTAP 7.3 Software Setup Guide

Page 109: N Series Data ONTAP Software Setup Guide

Time zones

You must select a valid time zone value from the lists provided, record it in the configurationworksheet, and enter the value at the setup prompt.

Data ONTAP uses time zones defined by the standard UNIX zoneinfo database. You can set yoursystem time zone using one of the following types of terms:

• A geographic region, usually expressed as area/location• Greenwich Mean Time (GMT) or the difference in hours from GMT• A valid alias; that is, a term defined by the standard to refer to a geographic region or GMT• A system-specific or other term not associated with a geographic region or GMT

The following are examples of valid aliases:

Alias Standard reference

Jamaica US/Eastern

Navajo US/Mountain

UCT GMT

UTC

Universal

Zulu

In most cases, you should select an appropriate geographical or GMT term unless you have specialrequirements in your environment.

If you need to change your selected time zone after setup is complete, you can use the timezonecommand.

For more information about time zones in Data ONTAP, see the timezone(1) and zoneinfo(5) manpages.

Next topics

Time zones by geographical region on page 110

GMT offset and miscellaneous time zones on page 115

Time zones | 109

Page 110: N Series Data ONTAP Software Setup Guide

Time zones by geographical regionThe names of geographical time zones that are valid in Data ONTAP combine an area and location,in which the latter can be a major city, region, or other geographical feature. You should find themost accurate combination for you and enter it at the setup prompt.

Africa

Africa/Abidjan Africa/Djibouti Africa/Maputo

Africa/Accra Africa/Douala Africa/Maseru

Africa/Addis_Ababa Africa/Freetown Africa/Mbabane

Africa/Algiers Africa/Gaborone Africa/Mogadishu

Africa/Asmera Africa/Harare Africa/Monrovia

Africa/Bamako Africa/Johannesburg Africa/Nairobi

Africa/Bangui Africa/Kampala Africa/Ndjamena

Africa/Banjul Africa/Khartoum Africa/Niamey

Africa/Bissau Africa/Kigali Africa/Nouakchott

Africa/Blantyre Africa/Kinshasa Africa/Ouagadougou

Africa/Brazzaville Africa/Lagos Africa/Porto-Novo

Africa/Bujumbura Africa/Libreville Africa/Sao_Tome

Africa/Cairo Africa/Lome Africa/Timbuktu

Africa/Casablanca Africa/Luanda Africa/Tripoli

Africa/Conakry Africa/Lumumbashi Africa/Tunis

Africa/Dakar Africa/Lusaka Africa/Windhoek

Africa/Dar_es_Salaam Africa/Malabo

America

America/Adak America/Grenada America/Noronha

America/Anchorage America/Guadeloupe America/Panama

America/Anguilla America/Guatemala America/Pangnirtung

America/Antigua America/Guayaquil America/Paramaribo

110 | Data ONTAP 7.3 Software Setup Guide

Page 111: N Series Data ONTAP Software Setup Guide

America/Aruba America/Guyana America/Phoenix

America/Asuncion America/Halifax America/Port_of_Spain

America/Atka America/Havana America/Port-au-Prince

America/Barbados America/Indiana America/Porto_Acre

America/Belize America/Indianapolis America/Puerto_Rico

America/Bogota America/Inuvik America/Rainy_River

America/Boise America/Iqaluit America/Rankin_Inlet

America/Buenos_Aires America/Jamaica America/Regina

America/Caracas America/Jujuy America/Rosario

America/Catamarca America/Juneau America/Santiago

America/Cayenne America/Knox_IN America/Santo_Domingo

America/Cayman America/La_Paz America/Sao_Paulo

America/Chicago America/Lima America/Scoresbysund

America/Cordoba America/Los_Angeles America/Shiprock

America/Costa_Rica America/Louisville America/St_Johns

America/Cuiaba America/Maceio America/St_Kitts

America/Curacao America/Managua America/St_Lucia

America/Dawson America/Manaus America/St_Thomas

America/Dawson_Creek America/Martinique America/St_Vincent

America/Denver America/Mazatlan America/Swift_Current

America/Detroit America/Mendoza America/Tegucigalpa

America/Dominica America/Menominee America/Thule

America/Edmonton America/Mexico_City America/Thunder_Bay

America/El_Salvador America/Miquelon America/Tijuana

America/Ensenada America/Montevideo America/Tortola

America/Fort_Wayne America/Montreal America/Vancouver

America/Fortaleza America/Montserrat America/Virgin

America/Glace_Bay America/Nassau America/Whitehorse

Time zones | 111

Page 112: N Series Data ONTAP Software Setup Guide

America/Godthab America/New_York America/Winnipeg

America/Goose_Bay America/Nipigon America/Yakutat

America/Grand_Turk America/Nome America/Yellowknife

Antarctica

Antarctica/Casey Antarctica/Mawson Antarctica/Palmer

Antarctica/DumontDUrville Antarctica/McMurdo Antarctica/South_Pole

Asia

Asia/Aden Asia/Irkutsk Asia/Qatar

Asia/Alma-Ata Asia/Ishigaki Asia/Rangoon

Asia/Amman Asia/Istanbul Asia/Riyadh

Asia/Anadyr Asia/Jakarta Asia/Saigon

Asia/Aqtau Asia/Jayapura Asia/Seoul

Asia/Aqtobe Asia/Jerusalem Asia/Shanghai

Asia/Ashkhabad Asia/Kabul Asia/Singapore

Asia/Baghdad Asia/Kamchatka Asia/Taipei

Asia/Bahrain Asia/Karachi Asia/Tashkent

Asia/Baku Asia/Kashgar Asia/Tbilisi

Asia/Bangkok Asia/Katmandu Asia/Tehran

Asia/Beirut Asia/Krasnoyarsk Asia/Tel_Aviv

Asia/Bishkek Asia/Kuala_Lumpur Asia/Thimbu

Asia/Brunei Asia/Kuching Asia/Tokyo

Asia/Calcutta Asia/Kuwait Asia/Ujung_Pandang

Asia/Chungking Asia/Macao Asia/Ulan_Bator

Asia/Colombo Asia/Magadan Asia/Urumqi

Asia/Dacca Asia/Manila Asia/Vientiane

Asia/Damascus Asia/Muscat Asia/Vladivostok

Asia/Dubai Asia/Nicosia Asia/Yakutsk

112 | Data ONTAP 7.3 Software Setup Guide

Page 113: N Series Data ONTAP Software Setup Guide

Asia/Dushanbe Asia/Novosibirsk Asia/Yekaterinburg

Asia/Gaza Asia/Omsk Asia/Yerevan

Asia/Harbin Asia/Phnom_Penh

Asia/Hong_Kong Asia/Pyongyang

Atlantic

Atlantic/Azores Atlantic/Faeroe Atlantic/South_Georgia

Atlantic/Bermuda Atlantic/Jan_Mayen Atlantic/St_Helena

Atlantic/Canary Atlantic/Madeira Atlantic/Stanley

Atlantic/Cape_Verde Atlantic/Reykjavik

Australia

Australia/ACT Australia/LHI Australia/Queensland

Australia/Adelaide Australia/Lindeman Australia/South

Australia/Brisbane Australia/Lord Howe Australia/Sydney

Australia/Broken_Hill Australia/Melbourne Australia/Tasmania

Australia/Canberra Australia/NSW Australia/Victoria

Australia/Darwin Australia/North Australia/West

Australia/Hobart Australia/Perth Australia/Yancowinna

Brazil

Brazil/Acre Brazil/East

Brazil/DeNoronha Brazil/West

Canada

Canada/Atlantic Canada/Eastern Canada/Pacific

Canada/Central Canada/Mountain Canada/Saskatchewan

Canada/East- Saskatchewan Canada/Newfoundland Canada/Yukon

Time zones | 113

Page 114: N Series Data ONTAP Software Setup Guide

Chile

Chile/Continental Chile/EasterIsland

Europe

Europe/Amsterdam Europe/Kiev Europe/San_Marino

Europe/Andorra Europe/Kuybyshev Europe/Sarajevo

Europe/Athens Europe/Lisbon Europe/Simferopol

Europe/Belfast Europe/Ljubljana Europe/Skopje

Europe/Belgrade Europe/London (BST) Europe/Sofia

Europe/Berlin Europe/Luxembourg Europe/Stockholm

Europe/Bratislava Europe/Madrid Europe/Tallinn

Europe/Brussels Europe/Malta Europe/Tirane

Europe/Bucharest Europe/Minsk Europe/Vaduz

Europe/Budapest Europe/Monaco Europe/Vatican

Europe/Chisinau Europe/Moscow Europe/Vienna

Europe/Copenhagen Europe/Oslo Europe/Vilnius

Europe/Dublin Europe/Paris Europe/Warsaw

Europe/Gibraltar Europe/Prague Europe/Zagreb

Europe/Helsinki Europe/Riga Europe/Zurich

Europe/Istanbul Europe/Rome

Indian (Indian Ocean)

Indian/Antananarivo Indian/Comoro Indian/Mauritius

Indian/Chagos Indian/Kerguelen Indian/Mayotte

Indian/Christmas Indian/Mahe Indian/Reunion

Indian/Cocos Indian/Maldives

Mexico

Mexico/BajaNorte Mexico/BajaSur Mexico/General

114 | Data ONTAP 7.3 Software Setup Guide

Page 115: N Series Data ONTAP Software Setup Guide

Pacific

Pacific/Apia Pacific/Johnston Pacific/Ponape

Pacific/Auckland Pacific/Kiritimati Pacific/Port_Moresby

Pacific/Chatham Pacific/Kosrae Pacific/Rarotonga

Pacific/Easter Pacific/Kwajalein Pacific/Saipan

Pacific/Efate Pacific/Majuro Pacific/Samoa

Pacific/Enderbury Pacific/Marquesas Pacific/Tahiti

Pacific/Fakaofo Pacific/Midway Pacific/Tarawa

Pacific/Fiji Pacific/Nauru Pacific/Tongatapu

Pacific/Funafuti Pacific/Niue Pacific/Truk

Pacific/Galapagos Pacific/Norfolk Pacific/Wake

Pacific/Gambier Pacific/Noumea Pacific/Wallis

Pacific/Guadalcanal Pacific/Pago_Pago Pacific/Yap

Pacific/Guam Pacific/Palau

Pacific/Honolulu Pacific/Pitcairn

GMT offset and miscellaneous time zonesIf you are not using a standard geographical time zone, you must select a GMT value or other validterm and enter it at the setup prompt.

Tables in this section contain the following valid time zone values:

• Time zones defined by GMT offset (how many hours different they are from Greenwich MeanTime)

• Time zones that are not associated with a geographical region• Regional time zones that are not grouped by major land mass

GMT

GMT GMT+9 GMT-5

GMT+1 GMT+10 GMT-6

GMT+2 GMT+11 GMT-7

GMT+3 GMT+12 GMT-8

Time zones | 115

Page 116: N Series Data ONTAP Software Setup Guide

GMT+4 GMT+13 GMT-9

GMT+5 GMT-1 GMT-10

GMT+6 GMT-2 GMT-11

GMT+7 GMT-3 GMT-12

GMT+8 GMT-4

Etc

Etc/GMT Etc/GMT+11 Etc/GMT-9

Etc/GMT+0 Etc/GMT+12 Etc/GMT-10

Etc/GMT+1 Etc/GMT0 Etc/GMT-11

Etc/GMT+2 Etc/GMT-0 Etc/GMT-12

Etc/GMT+3 Etc/GMT-1 Etc/GMT-13

Etc/GMT+4 Etc/GMT-2 Etc/GMT-14

Etc/GMT+5 Etc/GMT-3 Etc/Greenwich

Etc/GMT+6 Etc/GMT-4 Etc/UCT

Etc/GMT+7 Etc/GMT-5 Etc/Universal

Etc/GMT+8 Etc/GMT-6 Etc/UTC

Etc/GMT+9 Etc/GMT-7 Etc/Zulu

Etc/GMT+10 Etc/GMT-8

Miscellaneous

Arctic/Longyearbyen HST Portugal

CET Iceland PRC

CST6CDT Iran PST8PDT

Cuba Israel ROC

EET Japan ROK

Egypt Kwajalein Singapore

Eire Libya Turkey

EST MET UCT

116 | Data ONTAP 7.3 Software Setup Guide

Page 117: N Series Data ONTAP Software Setup Guide

EST5EDT MST Universal

Factory MST7MDT UTC

GB Navajo WET

GB-Eire NZ W-SU

Greenwich NZ-CHAT Zulu

Hongkong Poland

System V

SystemV/AST4 SystemV/EST5EDT SystemV/PST8PDT

SystemV/AST4ADT SystemV/HST10 SystemV/YST9

SystemV/CST6 SystemV/MST7 SystemV/YST9YDT

SystemV/CST6CDT SystemV/MST7MDT

SystemV/EST5 SystemV/PST8

Time zones | 117

Page 118: N Series Data ONTAP Software Setup Guide
Page 119: N Series Data ONTAP Software Setup Guide

Supported languages

You must select a supported language from the list provided and record its abbreviation in theconfiguration worksheet.

Next topics

Specifying the language code on page 119

Language choices on page 119

Specifying the language codeWhen you enter language codes during setup, you might need to specify a suffix, such as UTF-8.

Step

1. When prompted during setup, enter the code that corresponds to the appropriate language. To useUTF-8 as the NFS character set, append UTF-8 to the abbreviation.

Example

ko.UTF-8

Language choicesWhen you respond to the setup prompt for language, you need to enter the language code(abbreviation).

Note: You can also view supported languages and their abbreviations by entering vol lang at thestorage system prompt.

Language Abbreviation Language Abbreviation

Arabic ar Norwegian no

Croatian hr Polish pl

Czech cs Portugese pt

Danish da POSIX C

Dutch nl Romanian ro

English en Russian ru

English (U.S.) en_US Simplified Chinese zh

Supported languages | 119

Page 120: N Series Data ONTAP Software Setup Guide

Language Abbreviation Language Abbreviation

Finnish fi Simplified Chinese(GBK)

zh.GBK

French fr Slovak sk

German de Slovenian sl

Hebrew he Spanish es

Hungarian hu Swedish sv

Italian it Traditional Chineseeuc-tw

zh_TW

Japanese euc-j ja Traditional ChineseBig 5

zh_TW.BIG5

Japanese PCK (sjis) ja_JP.PCK Turkish tr

Korean ko

120 | Data ONTAP 7.3 Software Setup Guide

Page 121: N Series Data ONTAP Software Setup Guide

Country codes

The country where the storage system is located must be specified by a two-character country code.

Code Country

AF Afghanistan

AL Albania

DZ Algeria

AS American Samoa

AD Andorra

AO Angola

AI Anguilla

AQ Antarctia

AG Antigua and Barbuda

AR Argentina

AM Armenia

AW Aruba

AU Australia

AT Austria

AZ Azerbaijan

PT Azores

BS Bahamas

BH Bahrain

ES Balearic Islands

ID Bali

BD Bangladesh

BB Barbados

BY Belarus

BE Belgium

Country codes | 121

Page 122: N Series Data ONTAP Software Setup Guide

Code Country

BZ Belize

BJ Benin

BM Bermuda

BT Bhutan

BO Bolivia

ID Borneo

BA Bosnia and Herzegovina

BW Botswana

BV Bouvet Island

BR Brazil

IO British Indian Ocean Territory

VG British Virgin Islands

BN Brunei Darussalem

BG Bulgaria

BF Burkina Faso

BI Burundi

TC Caicos Islands

CM Cameroon

CA Canada

CV Cape Verde

KY Cayman Islands

CF Central African Republic

TD Chad

CL Chile

CN China

HK China (Hong Kong S.A.R.)

MO China (Macau S.A.R.)

122 | Data ONTAP 7.3 Software Setup Guide

Page 123: N Series Data ONTAP Software Setup Guide

Code Country

CX Christmas Island

CC Cocos (Keeling) Islands

CO Colombia

KM Comoros

CG Congo

CD Congo, The Democratic Republic of the

CK Cook Islands

CR Costa Rica

CI Cote d'Ivoire

HR Croatia

CU Cuba

CY Cyprus

CZ Czech Republic

DK Denmark

DJ Djibouti

DM Dominica

DO Dominican Republic

TL East Timor

EC Ecuador

EG Egypt

SV El Salvador

GQ Equatorial Guinea

ER Eritrea

EE Estonia

ET Ethiopia

FK Falkland Islands (Malvinas)

FO Faroe Islands

Country codes | 123

Page 124: N Series Data ONTAP Software Setup Guide

Code Country

FJ Fiji

FI Finland

FR France

FX France Metropolitan

GF French Guiana

PF French Polynesia

TF French Southern Territories

GA Gabon

GM Gambia

GE Georgia

DE Germany

GH Ghana

GI Gibraltar

GR Greece

GL Greenland

GD Grenada

GP Guadaloupe

GU Guam

GT Guatemla

GN Guinea

GW Guinea-Bissau

GY Guyana

HT Haiti

HM Heard and McDonald Islands

HN Honduras

HU Hungary

IS Iceland

124 | Data ONTAP 7.3 Software Setup Guide

Page 125: N Series Data ONTAP Software Setup Guide

Code Country

IN India

ID Indonesia

IR Iran

IQ Iraq

IE Ireland

IL Israel

IT Italy

JM Jamaica

JP Japan

US Johnston Atoll

JO Jordan

KZ Kazakhstan

KE Kenya

KH Khmer Rep Cambodia

KI Kiribati

KP Korea, Democratic People's Republic of (North Korea)

KR Korea, Republic of (South Korea)

KW Kuwait

KG Kyrgyzstan

LA Lao People's Democratic Republic (Laos)

LV Latvia

LB Lebanon

LS Lesotho

LR Liberia

LY Libyan Arab Jamahiriya (Lybia)

LI Liechtenstein

LT Lithuania

Country codes | 125

Page 126: N Series Data ONTAP Software Setup Guide

Code Country

LU Luxembourg

MK Macedonia

MG Madagascar

MW Malawi

MY Malaysia

MV Maldives

ML Mali

MT Malta

MH Marshall Islands

MQ Martinique

MR Mauritania

MU Mauritius

YT Mayotte

MX Mexico

FM Micronesia, Federated States of

US Midway Island

MD Moldavia

MC Monaco

MN Mongolia

MS Montserrat

MA Morocco

MZ Mozambique

MM Myanmar

NA Namibia

NR Nauru

NP Nepal

NL Netherlands

126 | Data ONTAP 7.3 Software Setup Guide

Page 127: N Series Data ONTAP Software Setup Guide

Code Country

AN Netherlands Antilles

NC New Caledonia

NZ New Zealand

NI Nicaragua

NE Niger

NG Nigeria

NU Niue

NF Norfolk Island

MP Northern Mariana Islands

NO Norway

OM Oman

PK Pakistan

PW Palau

PA Panama

PG Papua New Guinea

PY Paraguay

PE Peru

PH Philippines

PN Pitcairn

PL Poland

PT Portugal

PR Puerto Rico

QA Qatar

RE Reunion

RO Romania

RU Russia

RW Rwanda

Country codes | 127

Page 128: N Series Data ONTAP Software Setup Guide

Code Country

KN Saint Kitts and Nevis

LC Saint Lucia

VC Saint Vincent and the Grenadines

WS Samoa (Western)

SM San Marino

ST Sao Tome and Principe

SA Saudi Arabia

SN Senegal

YU Serbia

T9 Service Agent Test Systems

SC Seychelles

SL Sierra Leone

SG Singapore

SK Slovakia

SI Slovenia

SB Solomon Islands

SO Somalia

ZA South Africa

GS South Georgia and the South Sandwich Islands

ES Spain

LK Sri Lanka

US St. Croix

SH St. Helena

PM St. Pierre and Miquelon

US St. Thomas

SD Sudan

SR Suriname

128 | Data ONTAP 7.3 Software Setup Guide

Page 129: N Series Data ONTAP Software Setup Guide

Code Country

SJ Svalbard and Jan Mayen Islands

SZ Swaziland

SE Sweden

CH Switzerland

SY Syrian Arab Republic (Syria)

TW Taiwan

TJ Tajikistan

TZ Tanzania

TH Thailand

TG Togo

TK Tokelau

TO Tonga

TT Trinidad And Tobago

TN Tunisia

TR Turkey

TM Turkmenistan

TC Turks and Caicos Islands

TV Tuvalu

UG Uganda

UA Ukraine

AE United Arab Emirates (Abu Dhabi)

AE United Arab Emirates (Dubai)

GB United Kingdom

US United States

UM United States Minor Outlying Islands

99 Unknown

UY Uruguay

Country codes | 129

Page 130: N Series Data ONTAP Software Setup Guide

Code Country

UZ Uzbekistan

VU Vanuatu

VA Vatican City State (Holy See)

VE Venezuela

VN Vietnam

VG Virgin Islands (British)

VI Virgin Islands (U.S.)

US Wake Island

WF Wallis and Futuna Islands

EH Western Sahara

YE Yemen

YU Yugoslavia

ZM Zambia

ZW Zimbabwe

130 | Data ONTAP 7.3 Software Setup Guide

Page 131: N Series Data ONTAP Software Setup Guide

What to do if the system does not boot whenpowered on

If your system does not boot when you power it on for the first time, you can troubleshoot theproblem by following a series of steps appropriate to your system.

For the following systems, use the procedure provided in this guide.

• N3300 or N3600• N3400• N6000 series

For the following systems, use the procedure provided with the Installation and Setup Instructionsthat shipped with your system hardware.

• N7600, N7700, N7800, or N7900• N5000 series• N3700

Troubleshooting if the N6000 series, N3300, N3400, or N3600system does not boot

If your N6000 series, N3300, N3400, or N3600 system does not boot when you power it on, you cantroubleshoot the problem by following a series of steps.

Steps

1. Look for a description of the problem on the console.

Follow any instructions provided on the console.

2. Check all cables and connections, making sure they are secure.

3. Ensure that power is supplied and is reaching your system from the power source.

4. Make sure that the power supplies on your controller and disk shelves are working.

If the LEDs on a power supply are... Then...

Illuminated Proceed to the next step.

Not illuminated Remove the power supply and reinstall it, making sure that itconnects with the backplane.

5. Verify disk shelf compatibility and check the disk shelf IDs.

6. Ensure that the Fibre Channel disk shelf speed is correct.

What to do if the system does not boot when powered on | 131

Page 132: N Series Data ONTAP Software Setup Guide

If you have EXN2000 and EXN4000 shelves mixed in the same loop, set the shelf speed to 2 Gb,regardless of module type.

7. Check disk ownership to ensure that the disks are assigned to the system:

a. Verify that disks are assigned to the system by entering disk show.

b. Validate that storage is attached to the system, and verify any changes you made, by enteringdisk show -v.

8. Turn off your controller and disk shelves, and then turn on the disk shelves.

For information about LED responses, check the quick reference card that came with the diskshelf or the hardware guide for your disk shelf.

9. Use the onboard diagnostics to check that Fibre Channel disks in the storage system are operatingproperly.

a. Turn on your system and press Ctrl-C. Enter boot_diags at the LOADER> prompt.

b. Enter fcal in the Diagnostic Monitor program that starts at boot.

c. Enter 73 at the prompt to show all disk drives.

d. Exit the Diagnostic Monitor by entering 99 at the prompt, as needed.

e. Enter the exit command to return to LOADER.

f. Start Data ONTAP by entering autoboot at the prompt.

10. Use the onboard diagnostics to check that SAS disks in the storage system are operating properly.

a. Enter mb in the Diagnostic Monitor program.

b. Enter 6 to select the SAS test menu.

c. Enter 42 to scan and show disks on the selected SAS.

This displays the number of SAS disks.

d. Enter 72 to show the attached SAS devices.

e. Exit the Diagnostic Monitor by entering 99 at the prompt, as needed.

f. Enter the exit command to return to LOADER.

g. Start Data ONTAP by entering autoboot at the prompt.

11. Try booting your system again.

If your system... Then...

Boots successfully Proceed to set up the software.

Does not boot successfully Contact IBM technical support. The system might not have the boot imagedownloaded on the boot device.

132 | Data ONTAP 7.3 Software Setup Guide

Page 133: N Series Data ONTAP Software Setup Guide

Index/etc/hosts

verifying host name resolution 94/vol directory

about 96/vol/vol0 directory

CIFS access as C$ 96NFS access 96verification 96

/vol/vol0/home directoryCIFS access as HOME 96NFS access 96verification 96

A

ACPconfiguration requirements 57domain 57subnet 57subnet, about 57

Active Directoryauthentication requirements 28configuration requirements 52domain administrator 51time service requirements 29

active/active configurationsconfiguration requirements 33, 99

administration hostsconfiguration requirements 39requirements 25

administrative passwordsconfiguration requirements 38

authenticationActive Directory 28Windows NT4 26

AutoSupportRemote LAN Module (RLM) 54

B

Baseboard Management Controller (BMC)configuration requirements 53verifying 100

BIND DNSauthentication requirements 28

bmc command 100

C

CIFS/vol/vol0 access as C$ 96/vol/vol0/home access as HOME 96configuration requirements 47domain administrator 51Windows domain 48WINS servers 48

configuration worksheet 33country codes 121customer contact information

configuration requirements 53

D

Data ONTAP software imagescopy software images without installing 81copying from a UNIX client 81copying from a Windows client 83getting from IBM 84

Data ONTAP system filescopying the software image to the HTTP server 80downloading from IBM 82installation overview 85installation procedure for HTTP 88installation procedure from /etc/software 85managing from an HTTP server 80managing with the software command 91

DHCPconfiguration requirements 30

DHCPv6 servers not supported 31disk assign command 73DNS

authentication requirements 28configuration requirements 46verifying host-name resolution 94

domains, Active Directoryadministrator requirements 51

E

e0M interfaceconfiguration requirements 40

Index | 133

Page 134: N Series Data ONTAP Software Setup Guide

Ethernet interfacesconfiguration requirements 40

exportfs commandverifying storage availability 96

F

flow controlconfiguration requirements 43

G

gateway, default 43GbE interfaces

configuration requirements 40

H

host namesautomatically generated 94configuration requirements 38resolution 94

HTTP servicesconfiguration requirements 45

I

installing Data ONTAP softwareoverview 77prerequisites 77

Interface to Take Overconfiguration requirements 42

IP addressesconfiguration requirements 41verifying 93

K

KerberosDNS requirements 28time service requirements 29

L

languagesconfiguration requirements 39supported by Data ONTAP 119

licenses

managing 97licensing

verifying 97LUN ownership

assigning 73

M

machine location information 53management port

configuration requirements 40media type

configuration requirements 42

N

network interfacesACP requirements 57authentication requirements 29configuration requirements 40troubleshooting 94

Network Maskconfiguration requirements 41

Network Typeconfiguration requirements 42

NFS/vol/vol0 access 96/vol/vol0/home access 96client privilege requirements 97

NFS clientsexporting data to 97preparing to access storage 97

NISconfiguration name 47verifying host-name resolution 94

O

organizational units (OU)configuration requirements 52

P

partner IP addressconfiguration requirements 42

passwordsadministrative, configuration requirements 38

portsverifying failover 105

prefix length 41

134 | Data ONTAP 7.3 Software Setup Guide

Page 135: N Series Data ONTAP Software Setup Guide

R

Remote LAN Module (RLM)configuration requirements 54

RLMverifying 101

rlm command 101routing

configuration requirements 43

S

service locator recordsauthentication requirements 28

Service processorinformation for configuration 55

setupoverview 21troubleshooting 131verification 93, 131

setup command 60Setup Wizard

configuration requirements 30software update command 85SP

how to configure 70configuration information

SP 55information for configuration 55

storage system locationconfiguration requirements 39

subnet maskACP requirements 57configuration requirements 41

switchesconfiguration requirements 30

T

time servicesrequirements 29

time zones 39, 109

troubleshooting 131

U

UID-to-SID mappingactive/active configuration requirements 100

UNIXclient, requirements to manage storage system 25

UNIX hostmounting the system 82

V

verificationBMC connections and setup 100complete process 93, 131host-name resolution 94licensing 97network connections 93RLM connections and setup 101storage availability and licensing 96

vifsconfiguration requirements 30, 43

W

Windowsclient, requirements to manage storage system 25

Windows domainconfiguration requirements 48

Windows hostmapping the root directory to a client share 83

Windows NT4authentication requirements 26

WINS serversconfiguration requirements 48

Z

zonestime 39, 53, 109

Index | 135

Page 136: N Series Data ONTAP Software Setup Guide
Page 137: N Series Data ONTAP Software Setup Guide

����

NA 210-05189_A0, Printed in USA

GC27-2206-07