Upload
myson
View
239
Download
1
Tags:
Embed Size (px)
DESCRIPTION
The ULOW-E2 is MYSON’s latest product innovation and another exciting addition to our ever growing range of modern, energy efficient heating solutions. The ULOW-E2 is an innovative low water temperature radiator that we have combined with our latest heating technology. The result is an ultra unique heating concept that provides high heat outputs at low water temperatures without any compromise on style. (ref.25597)
Citation preview
MYSON
heatingthroughinnovation.
ULOW-E2.
01.0
5.20
13
Technology
LOW TEMPERATURE RADIATOR
25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:55 Page 2
HEATING THROUGHINNOVATION.
The key challenge for the UK heating industry, both now and in the future, is
how to develop new, more energy efficient ways of providing indoor comfort.
As one of the UK’s leading brands, MYSON have developed a reputation for
maximising the role of innovation and technology in our operations. We are
committed to helping improve indoor comfort and, at the same time, reduce
national CO2 emissions by developing energy efficient products that are capable
of operating effectively at low water temperatures.
02 Heating Through Innovation
MYSON is one of the oldest and most respected names in the heating industry.
We have been manufacturing radiators for over 50 years. All MYSON radiators
featuring our Eco logo are renewable energy compatible.
25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:56 Page 3
INTRODUCTION.
Introduct ion 03
Technology
The ULOW-E2 has been awarded
the prestigious 2013 red dot award
for product design.
Every year innovative design products
from around the world are selected
by a panel of leading experts
and awarded this internationally
recognised award.
Introducing the ultra unique ULOW-E2.
The ULOW-E2 is MYSON’s latest product innovation and another exciting
addition to our ever growing range of modern, energy efficient heating solutions.
The ULOW-E2 is an innovative low water temperature radiator that we have
combined with our latest heating technology. The result is an ultra unique
heating concept that provides high heat outputs at low water temperatures
without any compromise on style.
25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:56 Page 4
ULTRA BENEFITS & FEATURES.
04 Ultra Benef its & Features
Low temperature compatible
High savings potential
State-of-the-art design
Intelligent controls
Rapid response heating
Central connection technology
A high proportion of radiant heat
Ideal for renovations and new buildings
Extremely easy installation
System compatibility
Summer breeze effect
25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:57 Page 5
Ultra Benef its & Features 05
25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:57 Page 6
Ultra Intel l igent 06
Automatic intelligence.
The ULOW-E2 is a panel radiator with in-built fans and E2 technology. The E2
technology automatically and intelligently controls operation of the in-built fans
to ensure maximum performance.
The ULOW-E2 has two operating modes - static and dynamic. Static mode is
the most efficient way for the ULOW-E2 to operate, as it does not activate
the in-built fans and will work like a traditional radiator with the TRV being
the main control.
Dynamic mode utilises the in-built fans. This mode may be required during
winter months when the outside air temperature drops and additional output is
required to maintain a comfortable indoor temperature.
The intelligence behind the ULOW-E2 is that the fans will only operate when
they are required.
ULTRA INTELLIGENT.
Technology
25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:57 Page 7
Ultra Benef its & Features 07
25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:57 Page 8
ULTRA EFFICIENT.
08 Ultra Eff ic ient
ULOW-E2 is a low water temperature radiator with in-built fans for enhanced
convection, enabling heat sources to operate at their most energy efficient
settings.
A combination of radiant heat from its front and back water filled panels, plus
enhanced convection from in-built fans, mean that the ULOW-E2 produces
high heat outputs and rapidly achieves indoor comfort even with lower water
temperatures as demonstrated in the chart below.
Traditional boilers
Reducing the water temperature
of a boiler can increase a heating
systems performance. Typically this
would mean radiators would need
to increase in size to maintain a
comfortable room temperature,
however with the ULOW-E2 and
its increased outputs, radiators can
remain the same size.
70/55/20°C
60/50/20°C55/45/20°C
50/40/20°C45/35/20°C
40/35/20°C40/35/20°C
35/30/20°C
Traditional Radiators
ULOW-E2
25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:57 Page 9
Ultra Eff ic ient 09
Renewable heat sources
There are two benefits to using the ULOW-E2 with renewable technologies
such as heat pumps. Either to save space (Example 1) or to reduce the water
temperature even further to maximise the efficiency of the heat pump (Example 2).
Example 2
Heat Requirement: 800W
Flow & Return: 45°C / 35°C
SELECT Compact:
600mm x 1600mm (829W)
ULOW-E2:
600mm x 1600mm (1090W)
Flow & Return: 38°C / 33°C*
ULOW-E2:
600mm x 1600mm (830W)
*Heat pump is now working 7°C lower.
Example 1
Heat Requirement: 800W
Flow & Return: 45°C / 35°C
SELECT Compact:
600mm x 1600mm (829W)
ULOW-E2:
600mm x 1200mm (817W)
Saving 400mm of space
0
2.5
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
32.5
35.0
CO2 in t
Old
bui
ldin
g w
ith
a g
as b
oile
r an
d s
teel
ele
men
ts
CO2 consumption
CO2 reduction
ULO
W-E
2 in
co
mb
inat
ion
wit
h a
heat
pum
p
ULO
W-E
2 in
co
mb
inat
ion
wit
h a
cond
ensi
ng b
oile
r
Comparison of the ULOW-E2 incombination with heat pumps orcondensing boilers with the CO2
emissions of an existing installation.
CO2 reduction over aperiod of 15 years
Water Temperature (°C)
4.5
4
3.5
3
2.5
2
Seas
ona
l Per
form
ance
Fac
tor
(SP
F)
35 40 45 50 55 60
Ground Source Heat Pump
Air Source Heat Pump
The graph shows the effect on SPF when the system is operating at ultra low water temperatures.
25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:57 Page 10
10
ULTRA MODERN &ULTRA COMPACT.
Ultra Modern & Ultra Compact
The ULOW-E2 is a very stylish, flat panel design radiator with attractive round
hole grille and sophisticated control panel. It is available in both black and
white colour options. Its appearance will add a modern look and stylish feel to
any room or décor.
The enhanced convection of the ULOW-E2 means that it delivers higher heat
outputs than standard panel radiators of equivalent size. As a consequence,
smaller radiators can be installed in individual rooms - an important
consideration when operating low water temperature heating systems.
25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:58 Page 11
Ultra Rapid 11
ULTRA RAPID.
Due to its combination of both radiant heat and enhanced convection, plus
intelligent controls that automatically switch between static and dynamic
operation, the ULOW-E2 provides a rapid heat response even at low water
temperatures. Indoor comfort is quickly and efficiently achieved.
25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:58 Page 12
12 Ultra Flexible
25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:58 Page 13
Ultra Flexible 13
ULTRA FLEXIBLE.
More choice, more solutions
The ULOW-E2 has been specifically designed for optimum performance with
low water temperature heating systems. It can be quickly and easily installed as
a standalone heating solution or in combination with other types of heat emitters
suitable for low water temperature heating systems, including underfloor
heating, traditional panel radiators and fan convectors.
A good choice of heat emitters, in a retrofit project for example, may be to install
underfloor heating downstairs in a home, but upstairs, where underfloor
installation costs can be prohibitive, fit rooms with ULOW-E2s instead. The
ULOW-E2 is a flexible heating solution that can help improve the performance
of a heating system, save money on installation and running costs and enhance
the appearance of any home.
Living in comfort all year round
In winter the ULOW-E2 is an
efficient low temperature radiator,
providing a high level of control
ensuring perfect indoor comfort
throughout the home.
Summer breeze effect
During the summer months
the summer breeze of the
ULOW-E2 provides gentle air
movement to create a pleasant
breeze effect.
25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:58 Page 14
14 Ultra Simple Instal lat ion
Please note: A twin entry valve is required for the central connection.This must be purchased separately.
The ULOW-E2 has been designed to work with MYSON’s innovative central
connection system. This simple but extremely clever idea gives complete
planning and installation freedom. The position of the connection no longer
depends on the length of the radiator. Therefore, there is no need to wait for
the radiators to be sized before installation of the system pipework. Simply
position the connections at the centre point of where the radiator will be sited
and move on!
The central connection system is easy to install and provides significant benefits.
Once in operation, it will help the room feel warmer, faster, by distributing hot
water from the top of the ULOW-E2 downwards. It also helps ensure a balanced
and efficient system by directing the cooler water at the bottom of the unit to
the return connection.
ULTRA SIMPLEINSTALLATION.
25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:59 Page 15
Ultra Simple Instal lat ion 15
Tool-free service access
What is so special about service access for the ULOW-E2 is that not a single
tool is required for removing or replacing the component parts. All functional
units and electrical components are freely accessible and can be fitted by
means of plug connections and clamp-joints. This saves money and time for
maintenance and cleaning. The ULOW-E2 is cleaned just the same way as a
standard radiator. The fans sit on gliding cradles and can easily be slid out from
the side of the radiator.
The sliding cradles for the fans are
made of extremely flexible and
resistant plastic. They can be bent to
an angle of 90°. This is particularly
useful for narrow niches and narrow
side clearance with walls. Should
the fan need to be replaced, press
down the sliding cradle by hand
and remove it from the plug
connection/clamp-joint.
25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:59 Page 16
16 Ultra Control lable
ULTRA CONTROLLABLE.
Thermostat head
Temperature scale
THERMOSTAT HEAD
Main switch ON/OFF
Heating icon, RED
Cooling icon, BLUE
UP button
DOWN button
Temperature scale
TOUCHPAD
Boost button
Heating/Cooling button
Fans
87351011
12
694
TOUCHPAD - CONTROL PANEL
1
2
3
4
5
6
7
8
9
10
11
25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:59 Page 17
Technical Data 17
TECHNICAL DATA.
Motor Power and Weight.
Model
Water Content is approx 7.1 litres per metre length.
UnpackedWeight (kg)
ULOW 040 3.5 17.13 ULOW 060 4.9 24.59 ULOW 080 6.4 32.06 ULOW 100 7.8 39.70 ULOW 120 9.3 47.16 ULOW 140 10.8 53.02 ULOW 160 12.1 62.27
Sound Levels.
ModelSound Pressure (dBA) (at 2.5m)
ULOW 040 2 - 30.7 ULOW 060 4 22.9 32.6 ULOW 080 6 24.4 33.7 ULOW 100 8 25.4 34.4 ULOW 120 10 26.3 35.1 ULOW 140 12 26.9 35.6 ULOW 160 14 27.5 36.0
Sound levels tested in accordance with ISO 3741.
ModelΔT15 ΔT35ΔT20 ΔT25 ΔT30ΔT10
Heat Output (Watts)Operation
Mode
Static 74 126 184 247 314 385 Comfort 125 197 272 350 430 512 Boost 147 231 317 407 498 591 Static 111 189 276 371 471 577 Comfort 188 296 409 527 647 770 Boost 220 345 475 609 746 886
Static 148 252 368 494 628 770 Comfort 250 394 545 702 862 1026 Boost 294 461 634 813 996 1182 Static 185 315 460 618 785 962 Comfort 312 493 681 877 1077 1281 Boost 367 576 792 1016 1244 1476 Static 222 378 552 741 942 1154 Comfort 374 591 817 1052 1292 1537 Boost 440 690 950 1218 1492 1771
Static 259 441 644 865 1099 1346 Comfort 436 689 953 1227 1507 1793 Boost 514 806 1109 1422 1741 2067 Static 296 504 736 988 1256 1539 Comfort 499 788 1090 1403 1723 2051 Boost 587 921 1267 1624 1989 2361
ULOW 040
ULOW 060
ULOW 080
ULOW 100
ULOW 120
ULOW 140
ULOW 160
*Allow 7mm for back strap.
Performance Data.
Dimensions.
ModelNominal Height
(mm)Depth*(mm)
Length(mm)
ULOW 040 600 105 400 ULOW 060 600 105 600 ULOW 080 600 105 800 ULOW 100 600 105 1000 ULOW 120 600 105 1200 ULOW 140 600 105 1400 ULOW 160 600 105 1600
Figures for living room with 100m2 space according to VDI2081, ULOW-E2 type 22 600 (filled with water).
Fans with nominal rotation speed of 2000 RPM at 12 VDC.
PLEASE NOTE: ULOW-E2 should be sized based on comfort mode outputs.
Connections:4 x G ½" internal thread and 2 x G ¾" external thread, underside centre
Maximum positive operating pressure: Standard design: 10 bar
Maximum operating temperature: 60°C
Safety class: IP14Supply voltage: 230 V
NB. Static mode runs without fans.
For BTUs multiply Watts by 3.412.
Motor Power(W)
No.of FansComfort Boost
25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:59 Page 18
heatingthroughinnovation.
MYSON MYSON Eastern Avenue, Team Valley, Gateshead, Tyne & Wear NE11 0PG, UKT: 0845 402 3434, F: 0191 491 7568, [email protected], www.myson.co.uk
01.0
5.20
13
25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:55 Page 1