50
age 42 of 96 BILL OF QUANTITIES Amount Item Description Qty. Unit Rate Inr. Fs. Sub Structure Dewatering (Contactor to check Soil Investigation Report) Item Excavation from existing natural ground level to a required depth for Footing, Strap beams, Tie beams and service lines including necessary compaction. m3 Backfill with selected material in layers including watering and compaction as per the spec’s & engineer’s approval. m3 Cart away surplus excavated material off the site. m3 Filling in plinth with selected material including watering and compction as per the spec’s & engineer’s approval. Damp proof course/DPC for block work . Applying 44mm thick water proofing membrane and two coats of hot bitumen 115/15 over it . Above Tie beam all around Villa+ above tie beam of Compound Wall. m3 Not include Anti - termite treatment Pre – Costruction Anti –termite treatment “Dursban 4TC”including 20 years guarantee.(Supplier shoud be approved by the Engineer) Applied horizontally m2 Applied Vertically m2 Blinding including shuttering 50 mm thick PCC grade M 20, using SRC 250 kg/m3. m3 Concrete grade 25 using SRC 370 Kg/M3 RCC footings m3 Column necks m3 Tie/strap/plinth Beam m3 To Collection

My House Specification

Embed Size (px)

DESCRIPTION

house spec

Citation preview

Page 1: My House Specification

age 42 of 96

BILL OF QUANTITIES

Amount

Item Description Qty. Unit Rate Inr. Fs.

Sub – Structure

Dewatering (Contactor to check Soil Investigation Report) Item

Excavation from existing natural ground level to a required depth for Footing, Strap beams, Tie beams and service lines including necessary compaction.

m3

Backfill with selected material in layers including watering and compaction as per the spec’s & engineer’s approval.

m3

Cart away surplus excavated material off the site.

m3

Filling in plinth with selected material including watering and compction as per the spec’s & engineer’s approval. Damp proof course/DPC for block work . Applying 44mm thick water proofing membrane and two coats of hot bitumen 115/15 over it . Above Tie beam all around Villa+ above tie beam of Compound Wall.

m3

Not include

Anti - termite treatment Pre – Costruction Anti –termite treatment “Dursban 4TC”including 20 years guarantee.(Supplier shoud be approved by the Engineer)

Applied horizontally m2 Applied Vertically m2

Blinding including shuttering 50 mm thick PCC grade M 20, using SRC 250 kg/m3.

m3

Concrete grade 25 using SRC 370 Kg/M3 RCC footings m3 Column necks m3 Tie/strap/plinth Beam m3

To Collection

Page 2: My House Specification

age 43 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

Walls 200mm thick M3 Walls 300mm thick M3 Reinforcement steel : Ton Reinforcement steel of all dia.

SOLID BLOCK WORK: 200mm thk solid block work using SR Cement Below tie beams : M2

Septic Tank and Soak away/ contractor to Include here all related concrete works or Steel, etc….. Shuttering works Sides of footing M2 Sides of walls M2 Sides and soffits of floor beams M2 Soffits of slab M2 Sides of columns necks M2 Sides of slabs M2 Soffits of staircase and landings M2 Sides of tie beams/plinth beams, sides of M2 strap beam. Entrance steps sides & riser. M2 Sundries Laying 1000 g polythene sheet M2 1 Apply two coats of butimen emulsion to M2 concrete surface in touch with soil as per spec’s and engineer’s approval. Under ground water tank (1,500 gallons)

To Collection

Page 3: My House Specification

age 44 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

Super structure:

Walls 20mm thick M3 Columns M3 Floor beams M3 Solid slabs M3 Rib Slabs M2 Projections/ upstand / cills . M3

Staircases, steps and landings M3

Parapet and moulds M3

Foundation for A / C machines, pumps, Item water tanks etc., Grade slab 100mm thick M2 Foam concrete M3

REINFORCEMENT

Reinforcement steel of all dia. Ton A 142 – Mesh M2 Shuttering work:

Sides of walls M2 Sides of columns M2 Sides and soffits of floor beams M2 Soffits of solid slab M2 Sides of slabs M2

Soffits of staircase and landings

M2

Edge of risers M

To Collection

Page 4: My House Specification

age 45 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

Shuttering work: [Cont’d] Sides of parapet and moulds Sides and soffit of lintels / arches M3 Sides of Projections/ upstand / cills / lintels / Arches

Generally : The contractor will list here and price items shown on the drgs., mentioned in the specification or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

two coats of hot bitumen 115/15 over it . Above Tie beam all around

Villa+ above tie beam of Compound Wall

M2

Grond floor slab 4” thick M3

To Collection .

Page 5: My House Specification

age 46 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

Block work & plaster works

A

250mm thick insulated block work Autoclaved Aerated Concrete (AAC) Thermalite blocks .

B

200mm thick hollow block

C

200mm thick solid block

D 100mm thick hollow block work

E 200mm wide damp proof course

M

F

100mm wide damp proof course

M

G Internal plaster M2

H External plaster M2 I Ceiling plaster M2 J Duct plaster M2 K Angle Beds M2 L Expanded metal M M Other balance and miscellaneous wprks Lintels including reinforcement and

shuttering:

A

200 x 150mm

LM

B

100 x 150mm

LM

C

200 x 200mm

LM

A

B

D E

BOUNDARY WALL GATES: Gate Automatic Door ( car’s Gate) Front Pedestrain Gate Builder’s Work to install the two gates: (A+B).

O.H. & Profits ( for A+B) (Cotractor to fill in the percetage bracket.)

To Collection

Page 6: My House Specification

age 47 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

FLOOR FINISHES: Granite flooring cut to size with design and

pattern, polished smooth finish, fixed in accordance with Specifications and approval of owner and consultant. (F1) P C Rate: Granite steps with 2 strips (2cm each ) of flamed granite to avoid slipping as per specs and approval of owner and consultant .(F1a)

m2.

P.c Rate : m2. Marble flooring cut to size with design and

pattern, polished smooth finish, fixed in accordance with Specifications and approval of owner and consultant. (F2) P C rate : .

m2.

Marble steps in accordance with Specification and approval of owner and consultant. (F2a) P C rate : .. M2.

Granite Ceramic flooring , color pattern & size as per the approval of owner and consultant. (F3) P C rate : Ceramic floor tiles color , pattern and size as per the approval of owner and consultant..( F4) N.A

M2.

m2.

To Collection

Page 7: My House Specification

age 48 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

FLOOR FINISHES: [Cont’d]

Ceramic flooring tiles (non-slippery) colour pattern & size as per the approval of owner and consultant for toilets & washrooms for toilets & wash rooms. (F5)

M2

P C rate :

Ceramic flooring tiles, colour pattern & size as per the approval of owner and consultant. (F6)

P C Rate :

M2.

Interlock 60mm thick as per the approval of owner and consultant.(F7)

l.s

Interlock 80mm thick as per the approval of owner and consultant.(F8)

l.s

Mosaic tiles as per the approval of owner and

consultant.(F9)

Precast kerbston for the approval of owner and consultant . (F11) P C Rate :

l.s

( N.A )

To Collection Inr.

Page 8: My House Specification

age 49 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

WALL FINISHES

Fenomastic emulsion paint (Highly

Washable) from JOTUN over smooth plaster. (W1)

M2

Polyrthene Epoxy from Jotun system over

smooth plaster. ( for the external wall of villa ) (W3) Jotun semi epoxy ( Acrylic ) system over smooth plaster ( for compound wall) ( W3a)

M2

Glazed ceramic tiles cladding, colour as

per spec’s ,approval of owner &engineer. (W4) PC-rate AED15/m2

M2

CEILING FINISHES: Gypsum board ceiling with access panel as per spec’s, approval of owner and engineer (C1).

M2

Gypsum false ceiling tiles water proof type (600x600 mm) as per spec’s, approval of owner and engineer . (C2)

P.C : Rate :

M2.

Aluminium strip/tiles ceiling 10cm wide colour and patter as per approval of owner and engineer. (C3)

P.C : Rate :

M2.

To Collection

Page 9: My House Specification

age 50 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

Fenomastic emulsion paint (Highly

Washable) from JUTON over smooth plaster.(C4)

M2

Enamel oil paint (Highly Washable) from

Jotun over smooth plaster. (C5) N.A

M2

Glass Dome skylight design, as / the

approval of of owner and engineer.(C7)

M2

Wood works for the sitting area in Roof to be quoted seperately here.

l.s

Skirting: Granite skirting (S1) m Angled granite skirting parallel to steps.

(S1a)

m

Marble skirting (S2) M Angled Marble skirting parallel to steps

slope (S2a).

M

Granite Ceramic skirting (S3) M Granite Ceramic skirting (S3a) ( N.A ) Granite Ceramic skirting (S4) (N.A) M Ceramic skirting (non - slippery) (S5) (N.A) Ceramic skirting (S6) ( N.A ) M

Sloping Mosaic tiles skirting as per the approval of owner and consultant.(S9a)

M

Generally :

The contractor will list here and price items shown on the drgs., mentioned in the specification or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

To Collection

Page 10: My House Specification

age 51 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

EXTERNAL WORKS

Excavation and earth work for pavement works

A

Excavate to reduce levels

Not include

B

Remove surplus excavated material form site

Not include

C

Filling levelling with suitable soil and compacting to 95% dry density CBR 15%, generally over the site to levels as shown on Drawings

Not include

ing and kerbs (outside plot limit): Pav

D

Removal of existing (if any) interlocks, cement tiles kerb stones, etc(Width required by the D M shall be borne by main contractor ). and cart away the debris

Item

Not include

rbs Precast concrete upstand ke(Outside plot limit)

Not include

E

Kerb stones on concrete beds, painting with road marking reflective black and white paint, all necessary excavation, back-filling, concrete haunching and expansion joints including flexcell boards, sealants, etc., complete

M

Not include

F

- do - for inside the building

M

Not include

Concrete interlocking blocks (Outside plot limit)

G

80mm thick, on minimum 2" thick sand, 8" thick subkha fill as per specifications and dwgs.(F8)

Not include

H

- do - but 60mm thick interlock tiles(F7)

Not include

Inr To Collection

Page 11: My House Specification

age 52 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

INTERLOCK WORKS INSIDE THE : PLOT

A

60mm thk . as per the approval of the owner and the consultant . ( F7)

Generally :

The contractor will list here and price items shown on the drgs., mentioned in the specification or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

To Collection Inr

Page 12: My House Specification

age 53 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

Roofing & Waterproofing

A

Minimum 50 mm thick light weight foam concrete screed density 700 kg/m3 laid to slope, Smoothly Finish to receive water proofing membrane.

M2

B

One coat of cold Bituminous primer coat As per Specification.

M2

C

4 mm thick one layer waterproofing APP membrane as per specification.

M2

D

50 mm thick Extruded polystyrene heat insulation board / Roofmate OR Equivalent Approved.

M2

E One layer of Filter membrane (min.100 g /m2.

M2

F

Mosaic tiles (25x25x2cm) over mortar

M2

G

Mosaic skirting 250mm above 30mm Layer of 10 – 15 mm dia round aggregates as per Finishing schedule

M2

H

Roofing upstand including grooved fillet with mastic sealant ,1mm thick aluminium flashing shot fired to walls as shown in drawings.

M

J Extra over for water proofing details around rain water roof outlets

No

To Collection

Page 13: My House Specification

age 54 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

Roofing & Waterproofing [Cont’d]

WET AREAS

i

Apply water proofing as specified

ii

Horizontally

iii

Vertically

iv

90cm height of water proofing treatment to wall in contact with bath tub for toilets.

Generally :

The contractor will list here and price items shown on the drgs., mentioned in the specification or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

To Collection

Page 14: My House Specification

age 55 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

PLUMBING (WATER SUPPLY)

Contractor to submit the -Note:detailed shop drawings for water supply to the engineer before execution of work on site.

EQUIPMENT:

A

Transfer water supply pump set complete with one pump run the other standby and with necessary fitting for operations to be as per spec’s. and engineer’s approval

No.

B

Supply, install and connect ground floor Under ground tank with over head water tanks to be Fiber Glass 1000 Gallons POLYCON type as per spec’s, dwgs and engineer’s approval.

No.

C

Supply, install, fix and test booster pump sets with 2 pumps pressure vessels. The set shall be complete with steel base, strainers, non return valves, Gate valves ,Anble Valve,cut (on-off), pressure switch, pressure gauge, all softy devices, copper connections, pipes and control panels, float switch, etc. as per spec’s, dwgs and engineer’s approval.

No.

Supply and Installation of Aluminum water Proof Cat Ladder for over head water tank as per spec’s. and engineer’s approval.

No

To Collection

Page 15: My House Specification

age 56 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

[Cont'd] PLUMBING INSTALLATIONS

DOMESTIC WATER SERVICES : PIPE WORK

Supply & Install PVC Coated Copper pipes with fittings (over false ceiling) hot & cold water supply, including all short lengths, fittings, accessories, supports and sleeves, testing, etc., complete as per spec’s. and approved shop dwgs.

A

16mm diameter M

B

25mm diameter M

Supply & Install Cross linked polyethylene pipes-PEX with fittings (from false ceiling to water outlets sanitary ware) hot & cold water supply, including all short lengths, fittings, accessories, supports and sleeves, testing, etc., complete as per spec’s. and approved shop dwgs.

A

16mm diameter M

B

25mm diameter M

C

Domestic hot water piping from water heaters to pex manifold including fittings, accessories, etc, complete

M

Supply and install of UPVC Class Pipes (for roof & Exposed areas) Insulated with Rock wool & coated by canvas , foaster and aluminium foil 2mm thk. with fittings, accessories, supports and sleeves, testing, etc., complete as per spec’s. and approved shop dwgs. M

To Collection

Page 16: My House Specification

age 57 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

Polypropylene pipe (PPR pipes) work with solvent welded fittings, testing, etc., complete

20mm diameter No.

25mm diameter No. Supply & Install all connector pipes

between water supply line & sanitary fitting as per spec’s. No.

Installation of all pipes exposed on walls

and or below ceiling by using special galvanized steel with rubber lined. No.

Supply & Installation of all internally

exposed valves, mixers, angle, valves, and water taps to be as per the spec’s. and engineer’s approval. No.

Supply & Installation of W/C in bathroom

to be as per spec’s. and engineer’s approval.

No. No. No.

Supply & Installation of Water Pipe line

for future swimming pool to be as per spec’s. and engineer’s approval.

To Collection

Page 17: My House Specification

age 58 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

Supply and install glass lined water heaters, power connections, testing, warranty, etc as per spec’s.

Water heater; 60 liters; horizontal

P .C : Rate

Builder’s Work:

O.H. & Profits

Contactor to fill in the percentage bracket

Installation.

( %)

Supply and install glass lined water heaters, power connections, testing, warranty, etc as per spec’s

Water heater; 80 liters; horizontal

P .C : Rate

Builder’s Work:

O.H. & Profits

Contactor to fill in the percentage bracket

Installation.

To Collection

(%)

Page 18: My House Specification

age 59 of 96

A

DRAINAGR & STROM WATER:

and test the Supply , install, connect following UPVC under ground drains, complete with all accessories, solvent welded fittings, supports, sleeves, etc. & as per BS 4660/67 & as per specs.

40mm diameter M

B

50mm diameter M

C

80mm diameter M

D

100mm diameter M

E

150mm diameter M

F

200mm diameter M

Supply , install, connect and test the following UPVC pipe work for above ground soil, waste, rainwater and vent installations with all accessories, solvent welded fittings, supports,

, etc. & as per spec’s.sleeves

G

32mm diameter M

H

40mm diameter M

J

50mm diameter M

K

80mm diameter M

L

100mm diameter M

M

150mm diameter

M

N

200mm diameter

M

To Collection

Page 19: My House Specification

age 60 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

MANHOLE & INSPECTION ROOMS:

FLOOR TRAPS, FLOOR DRAINS & ROOF DRAINS

Supply and install Connect and test he following floor drainst

A

UPVC (Class E) floor traps, for External use as per spec’s. & dwgs. and Engineer's approval No.

B

Stainless steel floor traps, for Internal use as per spec’s. & dwgs. and Engineer's approval No.

C

UPVC (Class E) gully trap; as per spec’s. & dwgs. and Engineer's approval. No.

D

UPVC (Class E) roof drain outlets as per spec’s. & dwgs. and Engineer's approval No.

E

UPVC (Class E) floor drain outlets as per spec’s. & dwgs. and Engineer's approval No.

MANHOLES AND GT CHAMBER

A Construct waterproof manholes 200mm reinforced concrete or solid block-work walls; 150mm thick reinforced concrete base and cover slab with opening to suit the cover and frame; benching and rendering internally; complete including all necessary excavation, back-filling, bitumen coating disposal, etc. as per spec’s. & dwgs. and Engineer's approval

No.

B Construct waterproof gully trap chambers 200mm solid block-work walls; 100mm thick reinforced concrete base and over slab with opening to suit cover and frame; complete including all necessary excavation, back-filling, disposal, etc.

No.

To Collection

Page 20: My House Specification

age 61 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

Supply and install the following covers and frames as shown on the Drawings

A

600 x 600mm, recessed pattern, heavy-duty, double seal, with epoxy painting; for manholes

No.

B

600 x 600mm, cast iron, solid top, heavy

-duty, double seal, with epoxy painting; for manholes No.

C

300 x 300mm, recessed pattern, heavy-duty, double seal, with epoxy painting; for gully traps No.

D

300 x 300mm, cast iron, heavy duty, single seal; to all valve chambers No.

E

SANITARY WARE:

Sanitary ware and Others

Builder’s Work:

O.H. & Profits

Contactor to fill in the percentage bracket

Installation.

Generally :

The contractor will list here and price items shown on the drgs., mentioned in the specification or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

To Collection

Page 21: My House Specification

age 62 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

ELECTRICAL WORKS

A All Conduits & junction boxes should be of Ducab, Including necessary accessories as per dwgs and approval of the Engineer.

No.

No.

Supply, Installation, Testing & Commissioning of lighting fittings as per spec’s & dwgs approval of engineer for the following which includes:

No.

A Complete villa (Internal & External) No.

P.S : Builder’s Work:

O.H. & Profits

Contactor to fill in the percentage bracket

Installation.

(10 %)

Supply, Installation, Testing & Commissioning of lighting fixtures for the complete villa as per spec’s & dwgs approval of engineer for the following

A All boxes No.

B

Sockets (Internal)

No.

C Lighting switches(Internal) No.

D Sockets(External Weather proof) No.

E Lighting switches(External Weather proof) No.

To Collection

Page 22: My House Specification

age 63 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

ELECTRICAL WORKS [cont’d]

A Power points outlets No.

B Switches cover No.

C TV points No.

D

Telephones points No.

E

Copper earth term. No.

F

Pull Box/ Junction Boxes No.

G Dimmers No.

H Switch No. (To control the external lighting)

J Earthling system No.

K

Electrical outlet cocker in kitchen(45 Amps) No.

LVC (low voltage current):

A Telephone & TV connection No.

B Telephone sockets No.

C Telephone wires No.

D Sockets (CATV System) No. POWER SOCKETS

A Supply, Installation, Testing & Commissioning of power socket outlets 220 V-13Amps MK for the complete villa as per spec’s and approval

No.

B Supply, Installation, Testing & Commissioning of shaver socket outlets 220 V-13Amps MK for the complete villa as per spec’s and approval

No.

To Collection

Page 23: My House Specification

age 64 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

ELECTRICAL WORKS [cont’d]

C

Supply, Installation, Testing & Commissioning of twin power socket outlets 220 V-13Amps MK for the complete villa as per spec’s and approval. No.

D

Supply, Installation, Testing & Commissioning of power socket outlets 220 V-13Amps MK weather proof type for site & roof as per spec’s and approval

No.

E Supply, Installation, Testing & Commissioning of power socket outlets 220 V-45Amps MK as per dwgs, spec’s and approval .

No.

F Supply, Installation, Testing & Commissioning of power socket outlets 220 V-20Amps MK for water heater & washing machine as per dwgs, spec’s and approval .

No.

G Supply, installation, testing and commissioning of EXHAUST FANS as/spec,s dwgs. And the approval of the engineer.

No.

H Supply, installation, testing and commissioning of ELECTRIC BELL as/spec,s dwgs. And the approval of the engineer

No.

DISTRIBUTION PANEL BOARDS & METERS

Supply, Installation, Testing & Commissioning Of DISTRIBUTION PANEL BOARD 220V- 3PH 50Hz as per Schedule, spec’s and approval

No.

To Collection

Page 24: My House Specification

age 65 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

ELECTRICAL WORKS [cont’d]

A DB-BAS.F-20KW

B DB-GF-55KW No.

C DB-AC-90KW No.

D DB-FF-45KW No.

E DB-EXT-25KW No.

F DB-WP-10KW No.

G Isolators No.

H Circuit Breaker No. POWER CABLES:

A Supply, Installation, Testing & Commissioning Of POWER CABLE 4C 70mm2 XLPE/SWA/PVC CU+1C 35MM2 Y/G AS ECC from electric meter to internal panels as per Schedule, spec’s and approval.

No.

B Supply, Installation, Testing & Commissioning Of POWER CABLE 4C 25mm2 XLPE/SWA/PVC CU+1C 16 MM2 Y/G AS ECC as per Schedule, spec’s and approval

No.

C Supply and Installation of 3- Phase Electric Meter

INTERCOM & INTERPHONE SYSTEM

Supply, Installation, Testing, Commissioning, of intercom & interphone system-Low Voltage with all necessary conduits, pull boxes, junction boxes, cables and other accessories required as /spec’s dwgs. and approval of the engineer.

Builder’s Work:

O.H. & Profits

Contactor to fill in the percentage bracket

Installation.

No.

( 10 %)

To Collection

Page 25: My House Specification

age 66 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

ELECTRICAL WORKS [cont’d]

CENTRAL ANTENA&DISH ANTENA

SYSTEM:

Supply, Installation, Testing,

Commissioning, of the complete system

with all necessary conduits, pull boxes,

junction boxes, cables and other

accessories required as /spec’s dwgs.and

approval of the engineer. No.

Builder’s Work:

O.H. & Profits (10 %)

Contactor to fill in the percentage bracket

Installation.

:TV dishes

Conduits

Wires

Sockets (without covers)

Collection

Page 26: My House Specification

age 67 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

A/C & VENTILATION INSTALLATIONS

Rates within this element are to include for complying with each and every clause of the preliminaries, specification and method of measurement.

Include for the complete installation as described in the specification and as shown on the Drawings to give a complete system as well as the remote remote controlled thermostats, pipeing, ducting and insulation related to ducts and pipes and the control is separate for each room and space is acceptable to the Engineer and all local authorities and under the following sections

A Ducted split units including all supports, anti-vibration, mountings refrigerant pipes charge, accessories and integral controls as per schedules & spec’s, No.

Builder’s Work:

O.H. & Profits ( 15 %)

Contactor to fill in the percentage bracket Installation.

Contractor to quote seperately :

A Civil & electrical works related to A/C,

B All plumbing works

C Sleeves (PVC) for GAS route for protection

D shops drawing for all A/c works

E R.C.C. pads

To Collection

Page 27: My House Specification

age 68 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

ALUMINUM DOORS & WINDOWS

All Aluminum sections to be heavy duty powder coated 80 micron with the desired color and section 10.5 cm for windows, 12.5cm for doors, and box sections for all sliding panels and doors to be provided with fly mesh from inside , with necessary accessories.

Doors:

No

No.

Glazed Windows:

W1 No.

KW1

No.

W2

W3

No.

EW1

EW2

EW3

CW1

CW2(curtain wall)

CW5

DW1

To Collection

Page 28: My House Specification

age 69 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

A

: CAT & SPIRAL LADDERS

Supply & Installation of CAT & SPIRAL LADDERS from ground floor to terrace & then to roof as per Shop dwgs and Approval of Engineer

No.

A

RAILS:

Internal Railing : (staircase)

Supply & Installation of Aluminum powder coated railing as per details and Approval of Engineer.

P.C. Rate :

r m

B

External Railing :

Supply & Installation of Decorative Cast Aluminum coated railing as per details and Approval of Engineer.

P.C. Rate :

r m

Powder coated aluminum canopy/wooden Pergola

On first floor terrace contractor to consider as provisional sum of total value . N.A

Builders work :

O.H &profits

%(10 )

Generally :

The contractor will list here and price items shown on the drgs., mentioned in the specification or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

To Collection

Page 29: My House Specification

age 70 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

JOINARY WORKS: (Wooden)

All the external Doors to be Burma teak

Wood with bronze bolts and other ironmongery as per spec’s, dwgs and approval of the engineer.

A P.C Rate : no

Supply :

Installation:

D Supply and installation of All Internal Doors as per spec’s, dwgs and approval of the engineer.

P.S Rate :

No.

Supply :

Installation

E

Supply and installation of Sub-Frames for all doors as per spec’s, dwgs and approval of the engineer.

No.

To Collection

Page 30: My House Specification

age 71 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

WARDROBES:

Supply & Installation of wardrobes for all Bed / Dressing room as per spec’s and Approval of Engineer.

P.S : Builder’s Work

O.H. & Profits

Contractor to fill in the percentage Bracket

( 10 %)

CAR SHED:

Car Shed roof G R P panel as per the approved shop dwgs and Engineer’s Approval/ C6 M2

P.S :

Builder’s Work O.H. & Profits

Contractor to fill in the percentage Bracket

( 10 %)

STONE CLADDING IN CORNERS OF VILLA: As shown in drawings. M2 N.A.

GRC DECORATION PYRAMIDS ON ELEVATIONS: As shown in elevations. No. A.N

To Collection

Page 31: My House Specification

age 72 of 96

Item Description Qty. Unit Rate Inr. Fs.

KITCHEN CABINETS

Supply & Installation of Kitchen cabinets

In Ground as per spec’s and Approval of Engineer.

P.S : Rate :

Builder’s Work :

O.H. & Profits

VANITY COUNTERS

Supply & Install Vanity Counters in Ground floor(as per drawings)for wash & toilets etc., as per spec’s and approval of the engineer.

P.C : Rate :

M2

RM

(10 %)

1

Genarally:

The contractor will list here and price items shown on the drgs., mentioned in the specification or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

To Collection Inr

Page 32: My House Specification

age 73 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

COMPOUND WALL :

Sub - structure:

Excavation from existing natural ground level to a required depth for Footing including necessary compaction. M3

Backfill with selected material in layers including watering and compaction M3

Cart away surplus excavated material off the site.

Damp proof course/ DPC for block work .Applaying 4mm thick water proofing membrane and two coats of hot birumen 115/15 over it / Above tie beam. M3

Blinding including shuttering 50 mm thick PCC grade M 20, using SRC 250 kg/m3. M3

Concrete grade 30 using SRC 370 Kg/M3 RCC footings M3

Reinforcement steel of all dia.

tons 200mm thk solid block work using SR M2 Shuttering works Sides of footing M2 Sundries Laying 1000 g polythene sheet M2 Apply two coats of butimen emulsion to

concrete surface in touch with soil as per spec’s and engineer’s approval. M2

Super structure:

Concrete grade 30/20 using OPC 370 kg/m3

Columns m3 Coping Beams M3

To Collection

Page 33: My House Specification

age 74 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

[Cont’d]COMPOUND WALL:

Block Work:

200mm wide damp proof course m

200mm thick hollw block work M WALL FINISHES: Jotun Semi epoxy system over smooth

plaster. (W------) M2

Electrical Works:

Supply, Installation, Testing & Commissioning of All Electrical works for the compound wall as per spec’s & dwgs approval of engineer for the following

Genarally:

The contractor will list here and price items shown on the drgs., mentioned in the specification or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

To Collection

Page 34: My House Specification

age 75 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

EXTERNAL SERVICE BLOCK: Sub – Structure

Dewatering (Contactor to check Soil Investigation Report) Item

Excavation from existing natural ground level to a required depth for Footing, Strap beams, Tie beams and service lines including necessary compaction.

m3

Backfill with selected material in layers including watering and compaction as per the spec’s & engineer’s approval.

m3

Cart away surplus excavated material off the site.

m3

Filling in plinth with selected material including watering and compction as per the spec’s & engineer’s approval.

m3

Damp proof course/DPC for block work .Applaying 4mm thick water proofing membrane and two coats of hot birumen 115/15 over it / Above tie beam.

Anti - termite treatment Pre – Costruction Anti –termite treatment “Dursban 4TC”including 20 years guarantee.(Supplier shoud be approved by the Engineer)

Applied horizontally m2

Blinding including shuttering 50 mm thick PCC grade M 20, using SRC 250 kg/m3.

m3

Concrete grade 30 using SRC 370 Kg/M3 RCC footings m3

Column necks

m3

Tie/strap/plinth Beam m3

To Collection

Page 35: My House Specification

age 76 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

EXTERNAL BLOCK [con’d]

Reinforcement steel : Ton Reinforcement steel of all dia.

SOLID BLOCK WORK: 200mm thk solid block work using SR cement : Below tie beams M2 Shuttering works Sides of footing M2 Sides of columns necks M2 Sides of tie beams/plinth beams, sides of strap beam. M2 Entrance steps sides & riser. M2 Sundries Laying 1000 g polythene sheet M2 Apply two coats of butimen emulsion to concrete surface in touch with soil as per spec’s and engineer’s approval. M2

Generally : The contractor will list here and price items shown on the drgs., mentioned in the specification or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

To Collection

Page 36: My House Specification

age 77 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

EXTERNAL BLOCK : [Cont’d]

Super structure:

Walls 20mm thick M3 Columns M3 Floor beams M3 Solid slabs M3 Hourdy Rib slabs M2 Projections/ upstand / cills . M3 Staircases, steps and landings M3

Parapet and moulds M3

Foundation for A / C machines, pumps, Item water tanks etc., Grade slab 100mm thick M2

REINFORCEMENT

Reinforcement steel of all dia. Ton A 142 – Mesh M2 Shuttering work:

Sides of walls M2 Sides of columns M2 Sides and soffits of floor beams M2 Soffits of solid slab M2 Sides of slabs M2

Soffits of staircase and landings

M2

Edge of risers M

To Collection

Page 37: My House Specification

age 78 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

EXTERNAL BLOCK : [con’d]

Shuttering work: [Cont’d] Sides of parapet and moulds Sides and soffit of lintels / arches Sides of Projections/ upstand / cills / lintels / Arches Block work & plaster Works 250mm thick insulated block work

Autoclaved Aerated Concrete (AAC) Thermalite blocks .

M2

200mm thick hollow block M2

200mm thick solid block M2

100mm thick hollow block work M2 200mm wide damp proof course M2 100mm wide damp proof course M2 Internal plaster M2 External plaster M2 Ceiling plaster M2 Duct plaster M2 Angle Beds M2 Expanded metal M Other balance and miscellaneous wprks Lintels including reinforcement and

shuttering:

200 x 150mm 100 x 150mm 200 x 200mm

To Collection

Page 38: My House Specification

age 79 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

EXTERNAL BLOCK [con’d]

FLOOR FINISHES: Ceramic flooring tiles (non-slippery) colour

pattern & size as per the approval of owner and consultant for toilets & washrooms for toilets & wash rooms. (F5)

P C rate : M2 Ceramic flooring tiles colour pattern & size

as per the approval of owner and consultant. (F6)

P C Rate :

Mosaic tiles as per the approval of owner and

consultant .( F9)

M2

WALL FINISHES

Fenomastic emulsion paint (Highly Washable) from JOTUN over smooth plaster. (W1)

M2

Jotun polytheren system over smooth

plaster .( External walls only ) . (W3)

M2

Glazed ceramic tiles cladding, colour as

per spec’s ,approval of owner &engineer. (W4)

M2

CEILING FINISHES

Fenomastic emulsion paint (Highly Washable) from JUTUN over smooth plaster.(C4)

Enamel oil paint ( Highly washable ) over

smooth plaster ( C5)

M2

To Collection

Page 39: My House Specification

age 80 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

EXTERNAL BLOCK: [con’d]

Skirting: Ceramic skirting (S6)

Slopping mosaic tiles skirting (S9)

M2

EXTERNAL WORKS

M2

Excavation and earth work for pavement works

Excavate to reduce levels

Remove surplus excavated material form

site

M2

Filling levelling with suitable soil and

compacting to 95% dry density CBR 15%, generally over the site to levels as shown on Drawings

M2

Precast concrete upstand kerbs M2 Kerb stones on concrete beds, painting

with road marking reflective black and white paint, all necessary excavation, back-filling, concrete haunching and expansion joints including flexcell boards, sealants, etc., complete

M2

Concrete interlocking blocks 60mm thick, on minimum 2" thick sand, 8"

thick subkha fill as per specifications and dwgs.

To Collection

Page 40: My House Specification

age 81 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

EXTERNAL BLOCK [con’d]

Roofing & Waterproofing

A

Minimum 50 mm thick light weight foam concrete screed density 700 kg/m3 laid to slope, Smoothly Finish to receive water proofing membrane.

M2

B

One coat of cold Bituminous primer coat As per Specification.

M2

C

4 mm thick one layer waterproofing APP membrane as per specification.

M2

D

50 mm thick Extruded polystyrene heat insulation board / Roofmate OR Equivalent Approved.

M2

E One layer of Filter membrane (min.100 g /m2.

M2

F

Mosaic tiles (25x25x2cm) over mortar

M2

G

Mosaic skirting 250mm above 30mm Layer of 10 – 15 mm dia round aggregates as per Finishing schedule

M2

H

Roofing upstand including grooved fillet with mastic sealant ,1mm thick aluminium flashing shot fired to walls as shown in drawings.

M

J Extra over for water proofing details around rain water roof outlets

No

To Collection

Page 41: My House Specification

age 82 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

EXTERNAL BLOCK [con’d]

[Cont'd] PLUMBING INSTALLATIONS

DOMESTIC WATER SERVICES : PIPE WORK

Supply & Install PVC Coated Copper pipes with fittings (over false ceiling) hot & cold water supply, including all short lengths, fittings, accessories, supports and sleeves, testing, etc., complete as per spec’s. and approved shop dwgs.

A

16mm diameter M

B

25mm diameter M

Supply & Install Cross linked polyethylene pipes-PEX with fittings (from false ceiling to water outlets sanitary ware) hot & cold water supply, including all short lengths, fittings, accessories, supports and sleeves, testing, etc., complete as per spec’s. and approved shop dwgs.

A

16mm diameter M

B

25mm diameter M

C

Domestic hot water piping from water heaters to pex manifold including fittings, accessories, etc, complete

M

Supply and install of UPVC Class Pipes (for roof & Exposed areas) Insulated with Rock wool & coated by canvas , foaster and aluminium foil 2mm thk. with fittings, accessories, supports and sleeves, testing, etc., complete as per spec’s. and approved shop dwgs. M

To Collection

Page 42: My House Specification

age 83 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

EXTERNAL BLOCK [con’d]

Polypropylene pipe (PPR pipes) work with solvent welded fittings, testing, etc., complete

20mm diameter No.

25mm diameter No. Supply & Install all connector pipes

between water supply line & sanitary fitting as per spec’s. No.

Installation of all pipes exposed on walls

and or below ceiling by using special galvanized steel with rubber lined. No.

Supply & Installation of all internally

exposed valves, mixers, angle, valves, and water taps to be as per the spec’s. and engineer’s approval. No.

Supply & Installation of W/C in bathroom

to be as per spec’s. and engineer’s approval.

No. No. No.

Supply and install glass lined water

heaters, power connections, testing, warranty, etc as per spec’s. No.

Water heater; 60 liters; horizontal

P .C : Rate AED 350

Builder’s Work:

O.H. & Profits

Contactor to fill in the percentage bracket

Installation. No. No.

To Collection

Page 43: My House Specification

age 84 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

EXTERNAL BLOCK [con’d]

DRAINAGR & STROM WATER:

Supply , install, connect and test the following UPVC under ground drains, complete with all accessories, solvent welded fittings, supports, sleeves, etc. & as per BS 4660/67 & as per specs.

40mm diameter

B 50mm diameter M

C 80mm diameter M 100mm diamete 150mm diameter 200mm diameter

Supply , install, connect and test the following UPVC pipe work for above ground soil, waste, rainwater and vent

ll accessories, installations with asolvent welded fittings, supports, sleeves, etc. & as per spec’s.

32mm diameter 40mm diameter 50mm diameter 80mm diameter 100mm diameter 150mm diameter No.

To Collection

Page 44: My House Specification

age 85 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

EXTERNAL BLOCK [con’d]

MANHOLE & INSPECTION ROOMS:

OOR TRAPS, FLOOR DRAINS & FLROOF DRAINS

Supply and install Connect and test the following floor drains

A

UPVC (Class E) floor traps, for External use as per spec’s. & dwgs. and Engineer's approval No.

B

Stainless steel floor traps, for Internal use as per spec’s. & dwgs. and Engineer's approval No.

C

UPVC (Class E) gully trap; as per spec’s. & dwgs. and Engineer's approval. No.

D

UPVC (Class E) roof drain outlets as per spec’s. & dwgs. and Engineer's approval No.

E

UPVC (Class E) floor drain outlets as per spec’s. & dwgs. and Engineer's approval No.

MANHOLES AND GT CHAMBER

A Construct waterproof manholes 200mm reinforced concrete or solid block-work walls; 150mm thick reinforced concrete base and cover slab with opening to suit the cover and frame; benching and rendering internally; complete including all necessary excavation, back-filling, bitumen coating disposal, etc. as per spec’s. & dwgs. and Engineer's approval

No.

B Construct waterproof gully trap chambers 200mm solid block-work walls; 100mm thick reinforced concrete base and over slab with opening to suit cover and frame; complete including all necessary excavation, back-filling, disposal, etc.

No.

To Collection

Page 45: My House Specification

age 86 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

EXTERNAL BLOCK [con’d]

Supply and install the following covers and frames as shown on the Drawings

A

600 x 600mm, recessed pattern, heavy-duty, double seal, with epoxy painting; for manholes

No.

B

600 x 600mm, cast iron, solid top, heavy

-duty, double seal, with epoxy painting; for manholes No.

C

300 x 300mm, recessed pattern, heavy-duty, double seal, with epoxy painting; for gully traps No.

D

300 x 300mm, cast iron, heavy duty, single seal; to all valve chambers No.

Generally :

The contractor will list here and price items shown on the drgs., mentioned in the specification or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

SANITARY WARE :

Sanitary ware and Others

Builder’s Work:

O.H. & Profits

Contactor to fill in the percentage bracket

Installation.

(10 %)

To Collection

Page 46: My House Specification

age 87 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

EXTERNAL BLOCK [con’d]

ELECTRICAL WORKS

A All Conduits & junction boxes should be of Ducab, Including necessary accessories as per dwgs and approval of the Engineer.

No.

No.

Supply, Installation, Testing & Commissioning of lighting fittings as per spec’s & dwgs approval of engineer for the following which includes:

No.

External Block

Builder’s Work:

O.H. & Profits

Contactor to fill in the percentage bracket

Installation.

( 10 %)

Supply, Installation, Testing & Commissioning of lighting fixtures for external block as per spec’s & dwgs approval of engineer for the following

A All boxes No.

B

Sockets (Internal)

No.

C Lighting switches(Internal) No.

D Sockets(External Weather proof) No.

E Lighting switches(External Weather proof) No.

To Collection

Page 47: My House Specification

age 88 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

EXTERNAL BLOCK [con’d]

ELECTRICAL WORKS [cont’d]

A Power points outlets No.

B Switches cover No.

C TV points No.

D

Telephones points No.

E

Copper earth term. No.

F

Pull Box/ Junction Boxes No.

G Dimmers No.

H Switch No. (To control the external lighting)

J Earthling system No.

K

Electrical outlet cocker in kitchen(45 Amps) No.

LVC (low voltage current):

A Telephone & TV connection No.

B Telephone sockets No.

C Telephone wires No.

D Sockets (CATV System) No. POWER SOCKETS

A Supply, Installation, Testing & Commissioning of power socket outlets 220 V-13Amps MK as per spec’s and approval

No.

B Supply, Installation, Testing & Commissioning of shaver socket outlets 220 V-13Amps MK as per spec’s and approval

No.

To Collection

Page 48: My House Specification

age 89 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

EXTERNAL BLOCK [con’d]

ELECTRICAL WORKS [cont’d]

C

Supply, Installation, Testing & Commissioning of twin power socket outlets 220 V-13Amps MK as per spec’s and approval. No.

D

Supply, Installation, Testing & Commissioning of power socket outlets 220 V-13Amps MK weather proof type for site & roof as per spec’s and approval

No.

E Supply, Installation, Testing & Commissioning of power socket outlets 220 V-45Amps MK as per dwgs, spec’s and approval .

No.

F Supply, Installation, Testing & Commissioning of power socket outlets 220 V-20Amps MK for water heater & washing machine as per dwgs, spec’s and approval .

No.

G Supply, installation, testing and commissioning of EXHAUST FANS as/spec,s dwgs. And the approval of the engineer.

No.

To Collection

Page 49: My House Specification

age 90 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

EXTERNAL BLOCK [con’d] A/C & VENTILATION INSTALLATIONS

Rates within this element are to include for complying with each and every clause of the preliminaries, specification and method of measurement.

Include for the complete installation as described in the specification and as shown on the Drawings to give a complete system as well as the remote remote controlled thermostats, pipeing, ducting and insulation related to ducts and pipes and the control is separate for each room and space is acceptable to the Engineer and all local authorities and under the following sections

A Split units Decorative type mountings charge, accessories as per schedules & spec’s,

No.

Builder’s Work:

O.H. & Profits ( 10 %)

Contactor to fill in the percentage bracket Installation.

Contractor to quote seperately :

A Civil & electrical works related to A/C,

B All plumbing works

C Sleeves (PVC) for GAS route for protection

D shops drawing for all A/c works

E R.C.C. pads

To Collection

Page 50: My House Specification

age 91 of 96

Amount

Item Description Qty. Unit Rate Inr. Fs.

EXTERNAL BLOCK [con’d]

ALUMINUM DOORS & WINDOWS

All Aluminum sections to be heavy duty powder coated 80 micron with the desired color and section 10.5 cm for windows, 12.5cm for doors, and box sections for all sliding panels and doors to be provided with fly mesh from inside , with necessary accessories.

Doors:

A

ED1:

No

B ED2

Glazed Windows:

A

EW1:

No.

B

EW2

No.

C

EW0

JOINARY WORKS: (Wooden)

Supply and installation of All Internal

Doors as per spec’s, dwgs and approval of the engineer.

D2,D3,D5 : -

Supply and installation of Sub-Frames for

all doors as per spec’s, dwgs and approval of the engine

Kitchen cabinet :

P.S rate

Builders work :

O.H & profits

( 10 )%

Shelves at store :

P.S Rate

Builders Work :

O.H & Profits

( 10 ) %

To Collection