11
Brendan Kiburg, Jarek Kaspar May 21, 2018 Muon g-2 AEM Update

Muon g-2 AEM UpdateMuon g-2 It was an alright week for Muon g-2 May 21, 2018 Update for BAM 2 • Kicker 2 repairs Mo to Wed • Stable running Thu and most of Fri • Kicker 1 thyratron

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Brendan Kiburg, Jarek Kaspar May 21, 2018

Muon g-2 AEM Update

Muon g-2

It was an alright week for Muon g-2

May 21, 2018 Update for BAM 2

•  Kicker 2 repairs Mo to Wed•  Stable running Thu and most of Fri•  Kicker 1 thyratron power supply problem on Fri•  More kicker 2 problems on Sat•  Switched to field program for the rest of the weekend•  Kicker 2 repairs ongoing

Muon g-2May 21, 2018 Update for BAM 3

Added 12 % of BNL in last week

Muon g-2

Computing

May 21, 2018 Update for AEM 4

•  Efficiency improved with a new software release •  Reconstruction catching up raw data rate

Muon g-2

•  a charging power supply charges up•  capacitor back to low voltage (700 V) that

is discharged•  through a transformer into•  a Blumlein, which is a HV capacitor (55

kV), that is discharged through•  four 50 Ohms resistors, which convert

high voltage into high current into•  in-vacuum plates, where the current

generates magnetic field that rotates momentum vector of muons

How a kick is made?

May 21, 2018 Management 5

Muon g-2

•  Kickers were observed to have ugly pulse shapes–  Corresponding CTAG drop

•  Friday, during AD downtime, opened up and found resistor in awful shape

•  Replaced Resistors, cleaned fluorinert chillers, recovered old pulse shape friday

Kicker 2, two weeks ago – Resistor Issues

May 21, 2018 Management 6

Muon g-2

•  Looks even worse than before•  Decided to call it à switch to field.

Kicker 2 a week ago

May 21, 2018 Management 7

Muon g-2

•  Burned 2 resistors•  Didn’t find a problem in vacuum

Kicker 2 a week ago

May 21, 2018 Management 8

Muon g-2

•  Looks even worse than before•  Decided to call it again à switch to field. Examined today.`

Kicker 2 on Saturday

May 21, 2018 Management 9

Muon g-2

•  Burned 2 resistors•  Problem in vacuum

Kicker 2 today

May 14, 2018 Management 10

Muon g-2

•  More kicker problems•  Last time we replaced what was broken•  This time we are replacing everything•  Two more days to recover, and store beam again

Summary

May 21, 2018 Management 11