46
For continual product development, LG reserves the right to change specifications without notice. ©LG Electronics Inc. Printed in Korea December. 2008 Designed by crimad. 2009 LG MULTI V Air Conditioning System Outdoor Unit MULTI V MINI MULTI V PLUS II MULTI V SYNC II MULTI V SPACE II 16 20 28 34 Indoor Unit Wall Mounted ARTCOOL Ceiling Cassette Ceiling Concealed Duct Ceiling & Floor Ceiling Suspended Floor Standing 49 50 52 56 60 61 62 & Accessory Network Solution & Accessory Remote Controller Central Controller Accessory 74 76 84 Heat Recovery Ventilator Features Installation & Maintenance Line-up Specifications 66 67 68 70 Enjoy a clean & comfortable life with MULTI V. 2009 Air Conditioning System http://www.lgeaircon.com Air Conditioning System 2009 Air Conditioner 20 Yeouido-dong, Yeongdeungpo-gu, Yeouido P.O.Box 335 Seoul, 150-721, Korea. Phone : +82-2-3777-7998 Fax : +82-2-3777-5136 http://www.lgeaircon.com Distributed by EU-MV091 10 38 64 72

Multi v Hz R410A)

Embed Size (px)

Citation preview

Page 1: Multi v Hz R410A)

For continual product development, LG

reserves the right to change specifications without notice.

©LG

Electronics Inc. Printed in K

orea Decem

ber. 2008 Designed by crim

ad.

2009LG

MU

LTI V Air C

onditioning System

Outdoor Unit

MULTI V MINI MULTI V PLUS IIMULTI V SYNC IIMULTI V SPACE II

16202834

Indoor Unit

Wall MountedARTCOOLCeiling CassetteCeiling Concealed DuctCeiling & FloorCeiling SuspendedFloor Standing

49505256606162

& AccessoryNetwork Solution& AccessoryRemote ControllerCentral ControllerAccessory

747684

Heat Recovery VentilatorFeaturesInstallation & MaintenanceLine-upSpecifications

66676870

Enjoy a clean & comfortable life with MULTI V.

2009

Air Conditioning System

http://w

ww.lg

eaircon.com

Air Conditioning System

2009

Air Conditioner20 Yeouido-dong, Yeongdeungpo-gu,Yeouido P.O.Box 335 Seoul, 150-721, Korea.Phone : +82-2-3777 -7998 Fax : +82-2-3777- 5136

http://www.lgeaircon.com

Distributed by

EU-MV091

10

38

64

72

Page 2: Multi v Hz R410A)

Pyeongtaek in KoreaChangwon in Korea Thailand England France Australia Moscow Singapore

Spain Italy Dubai China Saudi Arabia Mexico Panama Indonesia Iran Turkey Vietnam

Global Air Conditioning Academies

Life’s Good! Frominstallationtomaintenanceandrepair,

LGruns30globalairconditioningacademies,providing

trainingforairconditioningprofessionalsaroundtheworld.

Establishment1947 EstablishmentoftheLGGroup1958 EstablishmentofLGElectronicsInc.

1962 EstablishmentofDigitalApplianceCompany

Growth1968 ManufacturedKorea’sfirstairconditioners1985 IntroducedKorea’sfirstInverterairconditioners1986 ExportedKorea’sfirstwindowtypeairconditioner

Expansion1995 EstablishmentofLGETAinChina1997 EstablishmentofLGEILinIndia1999 EstablishmentofLGEATinTurkey1999 EstablishmentofLGEVNinVietnam2001 EstablishmentofLGEAZinBrazil2002 EstablishmentofLGETHinThailand2002 EstablishmentofLGEINinIndonesia2004 TurnoverofUS$1.4Billiondollars2008 EstablishmentofLGELFinLevantCountries2008 EstablishmentofLGETKinTurkey

B r i e f H i s t o r y

Page 3: Multi v Hz R410A)

Yourlifecomesmorequiet,economicalandpowerfulwithLGairconditioninghightechnology.

Multi V Series

Environment

Economic

Easy Design & Installation

Engineering Support Indoor

Unit WallMountedARTCOOLCeilingCassetteCeilingConcealedDuctCeiling&FloorCeilingSuspendedFloorStanding

49505256606162

38

Outdoor Unit MULTIVMINI

MULTIVPLUSIIMULTIVSYNCIIMULTIVSPACEII

16202834

10

eco V(Heat Recovery Ventilator)

FeaturesInstallation&MaintenanceLine-upSpecifications

6667687064

V-net&Accessory

RemoteControllerCentralControllerAccessory

747684

72

Page 4: Multi v Hz R410A)

LG A

ir Conditioners System

06

_0

7M

ULTI V_

Outdoor unit Line up

Outdoor unit line up

HPMODEL 4 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64

*3Ø, 380V*1Ø, 220V

Page 5: Multi v Hz R410A)

LG A

ir Conditioners System

08

_0

9M

ULTI V_

Indoor unit Line up

Mirror

2way Cassette

1way Cassette

Low Static

Built-in

High Static

With Case

Without Case

Indoor unit line up

kW

Btu / h 18k 24k 28k 36k 42k 48k 76k 96k7k 9k 12k 15k

5.6 7.1 8.2 10.6 12.3 14.1 22.4 28.02.2 2.8 3.6 4.5

Series

Ceiling Cassette

Ceiling Concealed Duct

Floor Standing

Ceiling & Floor

Ceiling Suspended

SRAC Wall Mounted

(840*840)4way Cassette

(570*570)4way Cassette

5k

1.5

Page 6: Multi v Hz R410A)

LG A

ir Conditioners System

10_

11O

utdoor Unit_

MU

LTI V series

MULTIVInverterunitscomposedofseriallyarrangedrefrigerantpipesconnectedtoasingleoutdoorunitareanefficientsystemthatoffersoutstandingenergysaving,simpleandeasyinstallation,andconnectiontodifferenttypesofindoorunits,makingiteasytodesignandinstall.

Outdoor unit

MULTIVMINI

MULTIVPLUSII

MULTIVSYNCII

MULTIVSPACEII

16

20

28

34

M U LT I V o u t d o o r

Page 7: Multi v Hz R410A)

04

01

LG A

ir Conditioners System

12_13

Outdoor U

nit_M

ULTI V series

DCInverterCompressor

Oilinjectionmechanism- High reliability in low rpm operation- High efficiency in partial load operation

02

Oildischargereduction- High reliability in high rpm operation- Enhanced oil circulation

03

05

06

Tefloncoatedbearing

Highperformanceoilpump

Optimizedscrollshape

DCInvertermotor - High efficiency - Low noise

WorldHighestCOP!•DCInvertercompressor

•Invertercombination

•HighefficientDCInverterfan

•Widelouverheatexchanger

*Basedon10HPmodel

Inverter

ACompany

DC Inverter Compressor

Constant Speed Compressor

*25~105Hz

OtherFeaturesDCInverterfanmotor- Max RPM increased from 850 to 920 rpm - Power consumption decreased by 30~40%

01

UpgradedMainPCB

- 3-Digit 7 segment

- Double DIP switch

Main PCB

02

03

04

Widelouverheatexchanger- Improved heat exchange rate by 14%- Anti-corrosion treatment (Gold fin)

Blackboxfunction- Save the last 3 minutes operating data- Precise analysis & fast trouble-shooting

01

02

03 04

Corrugate fin

Widelouverfin

WideLouverheatexchanger

Inverter InverterInverterCombination•Increasedperformance&highCOP

•Fasterresponseforpartialload

•Optimizedcombinationwithspacesaving

•Competitivepriceforcustomers

•Reducedtotalbasemodelunits - Simple line-up (16 models > 5 models) - Easy stock & logistics management

3ØINVcontroller

Total piping length 1000m

ExtendedPipingLength•MULTIVPLUSII/SYNCII

•Refertothespecificationsformoreinformation

1stbranchtofarthestIndoor40m[90m**]Level

difference100m

Longestpipinglength150m(200m**)

•MULTIVPLUSII,MULTIVSYNCII

15m

*UsingYbranch

Pursuingthemarketneedsofhighenergyefficiencyandenvironmentalfriendliness.

Outdoor unitMULTIVMINI/MULTIVPLUSIIMULTIVSYNCII/MULTIVSPACEII

2009NewFeatures

** Conditional Application To make 40~90m of pipe length after first branch, refer to the part of “installation of outdoor units” in PDB

1000m

150m(200m**)

40m[90m**]

100m

15m

5m

Totalpipinglength

Longestpipinglength

Longestpipinglengthafter1stbranch

LeveldifferencebetweenODU~IDU

LeveldifferencebetweenIDU~IDU

LeveldifferencebetweenODU~ODU

05

06

01

04

03

02

Page 8: Multi v Hz R410A)

LG A

ir Conditioners System

14_

15O

utdoor Unit_

MU

LTI V series

Enhanced comfort for end-user!

* Based on MULTI V PLUS II, 10HP model

Night Silent OperationNight silent operation will be on for X hours starting from the peak temperature during daytime, and then after Y hours, it’ll be back to normal operation. - Mode 1 > X : 8.0 hours, Y : 9.0 hours - Mode 2 > X : 6.5 hours, Y : 10.5 hours - Mode 3 > X : 5.0 hours, Y : 12.0 hours

Each mode can be selected as 3 steps of sound level.

LG MV • Easy start-up, easy trouble shooting

• Monitoring the normality of all parts such as compressor, fan, valve, etc

• Operation state • Central Controller • Cycle view

Command

Sensor reading

LATS MULTI V • Convenient model selection program

• Highly user-friendly design (Autocad version)

• Automatic piping design & check

Download from sales supporting system> http://www.lgeaircon.com

• Model selection • Auto check

• CAD application • Making quotation

Pursuing the market needs of high energy efficiency and environmental friendliness.

Outdoor unit

Unit : dBA

MINI PLUS II SYNC IIStep 1Step 2Step 3

46

43

40

47

44

41

47

44

41

MULTI V MINI / MULTI V PLUS II MULTI V SYNC II / MULTI V SPACE II

2009 New Features

Automatic Refrigerant Charging• Refrigerant charging without any scales or quantity calculation

• This function is recommended during service.

• Guaranteed temperature range : IDU(20~32˚C), ODU(0~43˚C)

• FDD function (Fault detect & diagnosis)

Manifold

Refrigerant charging kit

Refrigerant

* Fault detect & diagnosis

Automatic Refrigerant Check-Up• It can be checked refrigerant status during start-up whether it is undercharged or overcharged

• It can be decided appropriate amount of refrigerant automatically through cycle operation.

• FDD function (Fault detect & diagnosis)

Leakage!

Leakage!

Leakage!

Leakage!

* Fault detect & diagnosis

Page 9: Multi v Hz R410A)

LG A

ir Conditioners System

16_

17O

utdoor Unit_

MU

LTI V MIN

I

EFFICIENCYMULTI V MINI uses the cutting-edge, artificial intelligence control to obtain efficient operation and reduced noise.

MULTI V MINI can be easily installed in small offices

and shops. Designed for low-noise operation,

it ensures a pleasant air conditioned environment.

Enjoy a clean & comfortable life with MULTI V MINI.

Day time Night time(Based on 4HP)

• Noise level (dBA)

Slim & Compact SizeEasy & efficient installation of MULTI V MINI will provide the best solution for small offices and shops.

4, 5, 6 HP5, 6 HP

• Foot print area

806mm

730mm

330mm

950mm

46%Reduction

• Volume

52%Reduction

WxHxD : 806×1607×730 WxHxD : 950x1380x330

Conventional

50 51 52

4HP 5HP 6HP STEP 1 STEP 2 STEP 3

404346

Enhanced Comfort• Night silent operation

• High COP

• Longest Piping Length

Cooling Heating Cooling Heating

4HP5HP6HP

1Ø, 220V 3Ø, 380V

3.93.73.6

4.04.03.8

3.73.63.5

3.93.93.8

Total piping length

Longest piping length (Equivalent)

Longest piping length after 1st branch

Level difference between ODU~IDU

Level difference between IDU~IDU

Level difference between ODU~ODU

300m

150m(175m)

40m

50m(40m*)

15m

5m

*Outdoor unit is lower than indoor unit.

Page 10: Multi v Hz R410A)

11.212.52.93.1

3.864.03

950 x 1380 x 330118

5052

110

1

3.7

FV50S[PVE] 1.7

Ø9.52(3/8)Ø15.88(5/8)

16

15.518.04.34.7

3.603.83

950 x 1380 x 330118

5254

110 1

3.7

FV50S[PVE] 1.7

Ø9.52(3/8)Ø19.05(3/4)

19

14.016.03.84.0

3.684.00

1, 220 ~ 240, 50950 x 1380 x 330

118

5153

110 1

3.7

FV50S[PVE] 1.7

Ø9.52(3/8)Ø15.88(5/8)

18

LG A

ir Conditioners System

18_

19O

utdoor Unit_

MU

LTI V MIN

I

Max. 9 Indoor Units ConnectableMaximum 9 indoor units can be connected to one single outdoor unit with 130% indoor unit combination.

- 9 indoor units for 6HP - 8 indoor units for 5HP - 6 indoor units for 4HP

Easy to Service

Inner SVC valve- 4 Way piping is possible (Front, Rear, Right, Down)

- Excellent exterior

01

Convenient moving handle02

units

*Based on 6 HP model

54321

876 9

1 Way 4 Way

Compact design & Easy service- Remove 3 pieces of screw for SVC- Front panel removal system

03

• DC Inverter Compressor & Fan motor

• Black Box Function

• Night Silent Operation

• Fault Detect & Diagnosis

• Pump Down

‘09 New Feature

3 pieces of screw

Easy service

MULTI V MINI can be easily installed in small offices

and shops. Designed for low-noise operation,

it ensures a pleasant air conditioned environment.

* Specifications

Capacity Cooling kW Heating kWPower Cooling kWInput Heating kWCOP Cooling HeatingPower Supply Ø, V, HzDimensions(WxHxD) mmWeight kgColorNoise level Cooling dBA±3 Heating dBA±3Fan Type Air flow rate [CMM]Compressor Type Number of compressorsHeat ExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping Liquid Pipes mm(inch)Connections Gas Pipes mm(inch)Number of outdoor unitNumber of maximum connectable indoor units

HP

Model 4

Ratio of the connectable indoor unitsLongest piping length / Level difference

65

EEV

Gold FinR410A

DC INVERTER

BLDC

Warm Gray

5 64

14.016.03.94.1

3.593.90

3, 380 ~ 415, 50950 x 1380 x 330

112

5153

110 1

3.7

FV50S[PVE] 1.3

Ø9.52(3/8)Ø15.88(5/8)

18

11.212.53.03.2

3.733.91

950 x 1380 x 330

112

5052

110

1

3.7

FV50S[PVE] 1.3

Ø9.52(3/8)Ø15.88(5/8)

16

15.518.0 4.44.8

3.523.75

950 x 1380 x 330

112

52 54

110 1

3.7

FV50S[PVE] 1.3

Ø9.52(3/8)Ø19.05(3/4)

19

EEV

Gold FinR410A

DC INVERTER

BLDC

Warm Gray

Independent Unit ARUN40GS2 ARUN60GS2ARUN50GS2 ARUN40LS2 ARUN60LS2ARUN50LS2

*1Ø, 220V *3Ø, 380V

150m/50m50~130%

150m/50m50~130%

Note :

1. Capacities are based on the following conditions Cooling-Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Heating-Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB

Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WBInterconnecting piping length 7.5m Interconnecting piping length 7.5mLevel difference of zero Level difference of zero

2. Capacities are net capacities3. Due to our policy of innovation some specifications may be changed without notification4. EEV : Electronic Expansion Valve

02

01

03

Page 11: Multi v Hz R410A)

LG A

ir Conditioners System

20_

21O

utdoor Unit_

MU

LTI V PLUS II

TECHNOLOGYYourlifewillbeupgradedthroughthestate-of-the-arttechnologyofMULTIVPLUSII.

Enjoyaclean&comfortablelifewithMULTIV.

*Based on 10HP model

Rear57dB

Side52dB

Front58dB

Alternate-CyclingFunction• Toextendcompressors’lifespanbyoperatingthemalternately

InverterA<>InverterB<>InverterC

ConstantA<>ConstantB<>ConstantC

• Tomeetdiverseloadinoperation

ON ON ON ON ON

InverterA

ConstantA

InverterB

ConstantB

InverterC

ConstantC

MULTIVInvertersystemoffersoneoftheworld’s

largestcapacityunits,essentialforhigh-risebuildings.

Weareproudtosaythesystemwillensurethehighest

levelofcustomersatisfaction.

ODU Noise Comparison

505 10 20 30 40

55

60

65

dBA

HP

70

Gernerally lower noise!!

LG Competitor

LowNoise• Latesttechnologyandfeaturesareappliedtothenewoutdoorunitstoreducenoiselevel.

Page 12: Multi v Hz R410A)

LG A

ir Conditioners System

22_23

Outdoor U

nit_M

ULTI V PLU

S II

CONVENIENCEFrom installation and transportation to maintenance and service, MULTI V PLUS II adds convenience to cutting-edge technology.

• Pump down

Refrigerant flow

Repair! Repair! Repair!

• Pump out

Refrigerant flow

Reftigerant flow

Failed!

Pump Down & Pump Out• Pump down When indoor units need to replace, refrigerant can be collected to the outdoor unit. - MULTI V MINI / PLUS II / SYNC II / SPACE II

• Pump out If left outdoor unit breakdown, refrigerant can be sent to another outdoor and indoor unit during service. - MULTI V PLUS II / SYNC II

Auto addressingAddressing outdoor units and indoor units are automatically done just by pressing the button.

Automatic Back-Up• For emergency, it makes back-up operation possible before trouble-shooting

Inverter A, B + Constant B > Inverter B + Constant A, B

• Error notice in indoor unit : 4 times per day (every 6 hour)

Plate Type SC HEX• Increased sub-cooling by high- performance heat exchanger

• Enable to be long piping length and level difference

• More powerful cooling operation

Double tube

Plate SC

Non-Polarity Transmission ConnectionEasy installation and no errors for transmission line connections

* Combination possible model only

Wired remote control

Wired remote control

Wired remote control

Indoor unit Indoor unit Indoor unit

Cool / Heat Selector• Control all units without any central controller installed

• Select operation mode (Air circulation, cooling, heating)

• Mode lock for heating & cooling mixing error-proof during the change of season

Mode change

Heating

Fan mode

Cooling

MULTI V Inverter system offers one of the world’s

largest capacity units, essential for high-rise buildings.

We are proud to say the system will ensure the highest

level of customer satisfaction.

ONFailed

InverterA

ConstantA

InverterB

ConstantB

ONONON

InverterA

ConstantA

InverterB

ConstantB

ONON

• • •3 4A 3 4

B

> or > or

43 43> or > or

Indoorunit 1

Outdoorunit

Indoorunit 2

43 43 43

• • •Indoor unit 1 Indoor unit 2

E F

Outdoorunit

B

Indoorunit

Outdoor unit control box

DC

Central controller

A Dry1 Dry2

Dry contact

GND 12V

Central controller

43

Page 13: Multi v Hz R410A)

LG A

ir Conditioners System

24_

25O

utdoor Unit_

MU

LTI V PLUS II

SeparateFrontPanel•EasyaccesstomainPCB(DIPswitch)

•Convenientduringserviceandstart-up

•Benefitsfortechnician,installer

Close Open

OtherFeatures•Resistanttodust,rain,corrosionandothers

•Convenientmaintenanceduetoswingdoortypecontrolbox

•Easytohandlethroughforkliftslot

•Strongbase-pansupport

•Safetychassis •Swingcontrolbox

•Easytohandle •Strongbase-pan

•DCInverterCompressor&Fanmotor

•BlackBoxFunction

•NightSilentOperation

•FaultDetect&Diagnosis

•PumpDown&PumpOut

‘09NewFeature

Checkupthenote,refertoonthe27page.

* Specifications5 6 16141210

ARUN60LT2ARUN60LT2

ARUN100LT2ARUN100LT2

ARUN120LT2ARUN120LT2

ARUN140LT2ARUN140LT2

ARUN160LT2ARUN160LT2

ARUN80LT2ARUN80LT2

8HPModel Combinationunit Independentunit

Capacity Cooling kW Heating kWPower Cooling kWInput Heating kWCOP Cooling HeatingPowerSupply Ø,V,HzDimensions(WxHxD) mmWeight kgColorNoiselevel dBA±3Fan Type Airflowrate [CMM]Compressor Type NumberofcompressorsHeatExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping LiquidPipes mm(inch)Connections GasPipes mm(inch)NumberofoutdoorunitNumberofmaximumconnectableindoorunits*

14.0

15.8

3.75

4.00

3.73

3.95

3, 380~415, 50

806×1607×730

175

56

105

1

4.5

2.3

Ø9.52(3/8)

Ø15.88(5/8)

1

8(12)

44.8

50.4

14.00

12.40

3.20

4.06

3, 380~415, 50

1280×1607×730

285

58

190

2

8

5.6

Ø12.7(1/2)

Ø28.58(1 1/8)

1

26(40)

39.2

44.1

11.85

10.60

3.31

4.16

3, 380~415, 50

1280×1607×730

285

58

190

2

8

5.6

Ø12.7(1/2)

Ø28.58(1 1/8)

1

23(35)

33.6

37.8

9.08

9.05

3.70

4.18

3, 380~415, 50

1280×1607×730

285

58

190

2

8

5.6

Ø12.7(1/2)

Ø28.58(1 1/8)

1

19(30)

28.0

31.5

7.16

7.33

3.91

4.30

3, 380~415, 50

1280×1607×730

285

58

190

2

8

EEV

5.6

Ø9.52(3/8)

Ø22.2(7/8)

1

16(25)

16.0

18.0

4.25

4.55

3.76

3.96

3, 380~415, 50

806×1607×730

175

56

105

1

4.5

2.3

Ø9.52(3/8)

Ø19.05(3/4)

1

9(14)

22.4

25.2

5.28

5.73

4.24

4.40

3, 380~415, 50

1280×1607×730

240

58

190

1

8

3.3

Ø9.52(3/8)

Ø19.05(3/4)

1

13(20)

ARUN50LT2ARUN50LT2

DC Inverter Scroll

Propeller Fan (DC INV)

Warm Gray

Gold finR410A

RatiooftheconnectableindoorunitsLongestpipinglength/Leveldifference**

50~200%

200m/100m

FVC68D(PVE)

MULTIVInvertersystemoffersoneoftheworld’s

largestcapacityunits,essentialforhigh-risebuildings.

Weareproudtosaythesystemwillensurethehighest

levelofcustomersatisfaction.

DC Inverter Scroll / Constant speed Scroll

Page 14: Multi v Hz R410A)

LG A

ir Conditioners System

26_

27O

utdoor Unit_

MU

LTI V PLUS II

* Specifications

ARUN180LT2ARUN120LT2ARUN60LT2

20 22 24 26 28 30 32ARUN320LT2ARUN160LT2ARUN160LT2

ARUN300LT2ARUN160LT2ARUN140LT2

ARUN280LT2ARUN140LT2ARUN140LT2

ARUN260LT2ARUN140LT2ARUN120LT2

ARUN240LT2ARUN160LT2ARUN80LT2

ARUN220LT2ARUN160LT2ARUN60LT2

ARUN200LT2ARUN140LT2ARUN60LT2

18HPModel Combinationunit Independentunit

Capacity Cooling kW Heating kWPower Cooling kWInput Heating kWCOP Cooling HeatingPowerSupply Ø,V,HzDimensions(WxHxD) mm

Weight kgColorNoiselevel dBA±3Fan Type Airflowrate [CMM]Compressor Type NumberofcompressorsHeatExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping LiquidPipes mm(inch)Connections GasPipes mm(inch)NumberofoutdoorunitNumberofmaximumconnectableindoorunits*

89.6

100.8

28.00

24.80

3.20

4.06

3, 380~415, 50

(1280×1607×730)×2

285x2

61

380

4

8+8

5.6x2

Ø19.05(3/4)

Ø34.9(1 3/8)

2

52(64)

84.0

94.5

25.85

23.00

3.25

4.11

3, 380~415, 50

(1280×1607×730)×2

285x2

61

380

4

8+8

5.6x2

Ø19.05(3/4)

Ø34.9(1 3/8)

2

49(60)

78.4

88.2

23.70

21.20

3.31

4.16

3, 380~415, 50

(1280×1607×730)×2

285x2

61

380

4

8+8

5.6x2

Ø19.05(3/4)

Ø34.9(1 3/8)

2

45(56)

72.8

81.9

20.93

19.65

3.48

4.17

3, 380~415, 50

(1280×1607×730)×2

285x2

61

380

4

8+8

5.6x2

Ø19.05(3/4)

Ø34.9(1 3/8)

2

42(52)

67.2

75.6

19.28

18.13

3.49

4.17

3, 380~415, 50

(1280×1607×730)×2

285+240

61

380

3

8+8

5.6+3.3

Ø15.88(5/8)

Ø34.9(1 3/8)

2

39(48)

61.6

69.3

18.25

16.95

3.38

4.09

3, 380~415, 50

(1280×1607×730)

+(806×1607×730)

285+175

60

295

3

4.5+8

5.6+2.3

Ø15.88(5/8)

Ø28.58(1 1/8)

2

35(44)

56.0

63.0

16.10

15.15

3.48

4.16

3, 380~415, 50

(1280×1607×730)

+(806×1607×730)

285+175

60

295

3

4.5+8

5.6+2.3

Ø15.88(5/8)

Ø28.58(1 1/8)

2

32(40)

50.4

56.7

13.33

13.60

3.78

4.17

3, 380~415, 50

(1280×1607×730)

+(806×1607×730)

285+175

60

295

3

4.5+8

5.6+2.3

Ø15.88(5/8)

Ø28.58(1 1/8)

2

29(36)

Warm Gray

Propeller Fan(DC INV)

DC Inverter Scroll / Constant speed Scroll

Gold fin

R410A

RatiooftheconnectableindoorunitsLongestpipinglength/Leveldifference**

50~160%

200m/100m

FVC68D(PVE)

MULTI V PLUS II ensures economic life with high energy efficiency!!

* Specifications50HP

Model Combinationunit Independentunit

Capacity Cooling kW Heating kWPower Cooling kWInput Heating kWCOP Cooling HeatingPowerSupply Ø,V,HzDimensions(WxHxD) mmWeight kgColorNoiselevel dBA±3Fan Type Airflowrate [CMM]Compressor Type NumberofcompressorsHeatExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping LiquidPipes mm(inch)Connections GasPipes mm(inch)NumberofoutdoorunitNumberofmaximumconnectableindoorunits

140

157.5

40.83

37.53

3.43

4.20

3, 380~415, 50

(1280x1607x730)x4

285X3+240

64

760

7

8+8+8+8

5.6X3+3.3

Ø19.05(3/4)

Ø41.3(1 5/8)

4

64

145.6

163.8

42.98

39.33

3.39

4.16

3, 380~415, 50

(1280x1607x730)x4

285X3+240

64

760

7

8+8+8+8

5.6X3+3.3

Ø19.05(3/4)

Ø41.3(1 5/8)

4

64

151.2

170.1

45.13

41.13

3.35

4.14

3, 380~415, 50

(1280x1607x730)x4

285X3+240

64

760

7

8+8+8+8

5.6X3+3.3

Ø19.05(3/4)

Ø41.3(1 5/8)

4

64

156.8

176.4

47.28

42.93

3.32

4.11

3, 380~415, 50

(1280x1607x730)x4

285X3+240

64

760

7

8+8+8+8

5.6X3+3.3

Ø19.05(3/4)

Ø41.3(1 5/8)

4

64

162.4

182.7

49.16

44.53

3.30

4.10

3, 380~415, 50

(1280x1607x730)x4

285x4

64

760

8

8+8+8+8

5.6x4

Ø19.05(3/4)

Ø41.3(1 5/8)

4

64

168

189

51.08

46.25

3.29

4.09

3, 380~415, 50

(1280x1607x730)x4

285x4

64

760

8

8+8+8+8

5.6x4

Ø19.05(3/4)

Ø41.3(1 5/8)

4

64

173.6

195.3

53.85

47.80

3.22

4.09

3, 380~415, 50

(1280x1607x730)x4

285x4

64

760

8

8+8+8+8

5.6x4

Ø19.05(3/4)

Ø41.3(1 5/8)

4

64

179.2

201.6

56.00

49.60

3.20

4.06

3, 380~415, 50

(1280x1607x730)x4

285x4

64

760

8

8+8+8+8

5.6x4

Ø19.05(3/4)

Ø41.3(1 5/8)

4

64

52 54 56 58 60 62 64ARUN500LT2ARUN140LT2ARUN140LT2ARUN140LT2ARUN80LT2

RatiooftheconnectableindoorunitsLongestpipinglength/Leveldifference**

50~130%

200m/100m

Warm Gray

Propeller Fan(DC INV)

DC Inverter Scroll / Constant speed Scroll

Gold finR410A

ARUN520LT2ARUN160LT2ARUN140LT2ARUN140LT2ARUN80LT2

ARUN540LT2ARUN160LT2ARUN160LT2ARUN140LT2ARUN80LT2

ARUN560LT2ARUN160LT2ARUN160LT2ARUN160LT2ARUN80LT2

ARUN580LT2ARUN160LT2ARUN160LT2ARUN160LT2ARUN100LT2

ARUN600LT2ARUN160LT2ARUN160LT2ARUN160LT2ARUN120LT2

ARUN620LT2ARUN160LT2ARUN160LT2ARUN160LT2ARUN140LT2

ARUN640LT2ARUN160LT2ARUN160LT2ARUN160LT2ARUN160LT2

FVC68D(PVE)

34ARUN340LT2ARUN140LT2ARUN140LT2ARUN60LT2

ARUN360LT2ARUN160LT2ARUN140LT2ARUN60LT2

ARUN380LT2ARUN160LT2ARUN160LT2ARUN60LT2

ARUN400LT2ARUN160LT2ARUN160LT2ARUN80LT2

ARUN420LT2ARUN140LT2ARUN140LT2ARUN140LT2

ARUN440LT2ARUN160LT2ARUN140LT2ARUN140LT2

ARUN460LT2ARUN160LT2ARUN160LT2ARUN140LT2

ARUN480LT2ARUN160LT2ARUN160LT2ARUN160LT2

48464442403836HPModel Combinationunit Independentunit

Capacity Cooling kW Heating kWPower Cooling kWInput Heating kWCOP Cooling HeatingPowerSupply Ø,V,HzDimensions(WxHxD) mm

Weight kgColorNoiselevel dBA±3Fan Type Airflowrate [CMM]Compressor Type NumberofcompressorsHeatExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping LiquidPipes mm(inch)Connections GasPipes mm(inch)NumberofoutdoorunitNumberofmaximumconnectableindoorunits

95.2

107.1

27.95

25.75

3.41

4.16

3, 380~415, 50

(1280×1607×730)×2

+(806×1607×730)

285x2+175

62

485

5

4.5+8+8

5.6x2+2.3

Ø19.05(3/4)

Ø34.9(1 3/8)

3

55

100.8

113.4

30.10

27.55

3.35

4.12

3, 380~415, 50

(1280×1607×730)×2

+(806×1607×730)

285x2+175

62

485

5

4.5+8+8

5.6x2+2.3

Ø19.05(3/4)

Ø41.3(1 5/8)

3

58

106.4

119.7

32.25

29.35

3.30

4.08

3, 380~415, 50

(1280×1607×730)×2

+(806×1607×730)

285x2+175

62

485

5

4.5+8+8

5.6x2+2.3

Ø19.05(3/4)

Ø41.3(1 5/8)

3

61

112.0

126.0

33.28

30.53

3.37

4.13

3, 380~415, 50

(1280×1607×730)×3

285x2+240

63

570

5

8+8+8

5.6x2+3.3

Ø19.05(3/4)

Ø41.3(1 5/8)

3

64

117.6

132.3

35.55

31.80

3.31

4.16

3, 380~415, 50

(1280×1607×730)×3

285×3

63

570

6

8+8+8

5.6x3

Ø19.05(3/4)

Ø41.3(1 5/8)

3

64

123.2

138.6

37.70

33.60

3.27

4.13

3, 380~415, 50

(1280×1607×730)×3

285×3

63

570

6

8+8+8

5.6x3

Ø19.05(3/4)

Ø41.3(1 5/8)

3

64

128.8

144.9

39.85

35.40

3.23

4.09

3, 380~415, 50

(1280×1607×730)×3

285×3

63

570

6

8+8+8

5.6x3

Ø19.05(3/4)

Ø41.3(1 5/8)

3

64

134.4

151.2

42.00

37.20

3.20

4.06

3, 380~415, 50

(1280×1607×730)×3

285×3

63

570

6

8+8+8

5.6x3

Ø19.05(3/4)

Ø41.3(1 5/8)

3

64

Warm Gray

Propeller Fan(DC INV)

DC Inverter Scroll / Constant speed Scroll

Gold finR410A

RatiooftheconnectableindoorunitsLongestpipinglength/Leveldifference**

50~130%200m/100m

FVC68D(PVE)

EEVEEV

EEV

• A combination operation over 100% cause to reduce each indoor unit capacity

•Combinationratio(50~200%)

No. of outdoor unit Connection CapacitySingle unit 200%Double unit 160%Triple unit 130%Over triple unit 130%

CAUTION

We can guarantee the operation only within 130% Combination.If you want to connect more than 130% combination, please contact us and discuss the requirement like below.

1) If the operation of indoor unit is more than 130%, low airflow operation is recommended in all the indoor units. 2) If the operation of indoor unit is more than 130%, additional refrigerant is needed according to the headquarter guidance. 3) Over 130%, capacity is same as capacity of 130%, Same remark is valid for power input.

1.Capacitiesarebasedonthefollowingconditions Cooling-Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Heating-Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB

Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WBInterconnecting piping length 7.5m Interconnecting piping length 7.5mLevel difference of zero Level difference of zero

2.Capacitiesarenetcapacities3.Duetoourpolicyofinnovationsomespecificationsmaybechangedwithoutnotification4.EEV:ElectronicExpansionValve

**ConditionalApplicationTomake40~90mofpipelengthafterfirstbranchrefertothepartof“installationofoutdoorunits”inPDB

*Thenumberof()meansthenumberofmax.connectableindoorunits,whentheconnectedcapacityofindoorunitsisinthetable below.

Note:

Page 15: Multi v Hz R410A)

LG A

ir Conditioners System

28_

29O

utdoor Unit_

MU

LTI V SYNC II

TECHNOLOGYYour life will be upgraded through the state-of-the-art technology of MULTI V SYNC II.

Heating & Cooling Synchronous Operation• High COP up to 6.3 - When, cooling(40%) + heating(60%)

• Energy consumption can be decreased by 30%

Simultaneous heating and cooling with one outdoor

unit, MULTI V SYNC II. Your environment is ensured of

optimum conditions regardless of season or space.

Enjoy a clean & comfortable life with MULTI V.

Cooling <

> Cooling

> Heating

Heating <

Heating Cooling

Office

Long Piping Length• MULTI V SYNC II

• Refer to the specifications for more information• MULTI V SYNC II

15m

AMC (Advanced Mode Change)

AMC control provides an optimal cycleoperation under any conditions.

- Real time pressure control- Optimal cycle in optimum area- Needed time to change mode : Max. 3min

Wide Operation Range

Wide operation range- Heating mode : - 20°C WB ~ 16°C WB- Cooling mode : - 5°C DB ~ 43°C DB- Synchronous mode : -10°C DB ~ 27°C DB

Heating

Cooling

SynchronousOperation area

1000m

150m(200m**)

40m[90m**]

100m

15m

5m

** Conditional application To make 40~90m of pipe length after first branch, refer to the part of “installation of outdoor units” in PDB

1st branch to farthest indoor 40[90m**]

Longest piping length 150(200m**)

Total piping length 1000m

Level difference

100m

Total piping length

Longest piping length

Longest piping length after 1st branch

Level difference between ODU~IDU

Level difference between IDU~IDU

Level difference between ODU~ODU

Equipment room

40

* Outdoor temperature : 7°C DB / 6°C WB

* Indoor temperature : 20°C DB / 15°C WB

Max. COP (6.3)

Coe

ffic

ient

of P

erfo

rman

ce(C

OP

)

Heating operation ratio (%)

Optimum area

Page 16: Multi v Hz R410A)

LG A

ir Conditioners System

30_

31O

utdoor Unit_

MU

LTI V SYNC II

FastResponseofModeChangeWhentheuserwantstochangetheindoorunit’soperatingmode(ex.cooling>heating),MULTIVSYNCIItakeslesstimecomparedtotheconventional.Thisfastresponseofmodechangeprovidesamorepleasantandcomfortableairconditioning.

•MULTIVSYNCII

•Conventional

Max. 3minutes

Heating Cooling

About 20minutes

Heating Cooling

ExcellentMultipleHRUnitLG’sHRunitprovidestheflexibleandconvenientinstallationwithlowercost.

LGneedslessinstallationcostthantheconventional

Ybranch

HRunit

Totalpipinglength

12unit

5unit

690m

57unit

20unit

840m

LG Conventional

*Assumedwith5storiesbuilding

•MULTIVSYNCII •Conventional

15m

20m

3PipingHRunit

2PipingHRunit

2Piping

3Piping

YBranch

COMFORTMULTIVSYNCIIensuresthecomfortofalluserswithflexibledesignandeasyinstallation.

HighEfficiencyHeatRecoveryUnit•HighefficientdoublespiraltubetypeSCIcircuit

•Maximum4indoorunitsconnectableperoneHRunit

•Easyinstallationwithautopipingdetectfunction

From outdoor

Toindoor

2 phase fluid

Linear expansion valve

•Doublespiraltubeheatexchanger

PRHR020 PRHR030 PRHR040

FlexibleConnectionofHRUnitLG’sheatrecoveryunitallowsflexibleconnectionbothinseriesandinarow.

•MULTIVSYNCII

LG unique LG unique

Inseries

•Conventional

Impossible

Impossible

Inseriesonly

Ybranchonly

AutoChangeoverAutochangeoverautomaticallychangeoperatingmodecoolandheat,tomaintainoptimumroomtemperature,sononeedofchangingthemodeduringthechangeofseason.

ConvenientFreeZoningMULTIVSYNCIIprovidesperfectindividualzoningineachroomsfortheuser’sconvenience.

•MULTIVSYNCII •Conventional

Free zoning! Inconvenient zoning!

Samemodeoperationinthedifferentzones

Temp

Time

Changepoint(Heat>Cool)

Changepoint(Cool>Heat)

+∆T

-∆T

Simultaneousheatingandcoolingwithoneoutdoor

unit,MULTIVSYNCII.Yourenvironmentisensuredof

optimumconditionsregardlessofseasonorspace.

Page 17: Multi v Hz R410A)

LG A

ir Conditioners System

32_33

Outdoor U

nit_M

ULTI V SYN

C II

•DCInverterCompressor&Fanmotor

•BlackBoxFunction

•NightSilentOperation

•FaultDetect&Diagnosis

•PumpDown&PumpOut

‘09NewFeatureMULTI V SYNC II simultaneous heating and cooling from a single outdoor unit!

36HPModel Combinationunit Independentunit

Capacity Cooling kW Heating kWPower Cooling kWInput Heating kWCOP Cooling HeatingPowerSupply Ø,V,HzDimensions(WxHxD) mmWeight kgColorNoiselevel dBA±3Fan Type Airflowrate [CMM]Compressor Type NumberofcompressorsHeatExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping Liquid(flare) mm(inch)Connections SuctionGas mm(inch) DischargeGas mm(inch)NumberofoutdoorunitNumberofmaximumconnectableindoorunits

40 464442 48

100.8

113.4

28.98

26.93

3.48

4.21

3, 380~415, 50

(1280x1607x730)x3

240+285+285

63

570

5

8+8+8

5.6+5.6+3.3

Ø19.05(3/4)

Ø41.3(1 5/8)

Ø28.58(1 1/8)

3

58

112.0

126.0

33.28

30.53

3.37

4.13

3, 380~415, 50

(1280x1607x730)x3

240+285+285

63

570

5

8+8+8

5.6+5.6+3.3

Ø19.05(3/4)

Ø41.3(1 5/8)

Ø34.9(1 3/8)

3

64

117.6

132.3

35.16

32.13

3.34

4.12

3, 380~415, 50

(1280x1607x730)x3

285+285+285

63

570

6

8+8+8

EEV

FVC68D(PVE)

5.6+5.6+5.6

Ø19.05(3/4)

Ø41.3(1 5/8)

Ø34.9(1 3/8)

3

64

123.2

138.6

37.7

33.6

3.27

4.13

3, 380~415, 50

(1280x1607x730)x3

285+285+285

63

570

6

8+8+8

5.6+5.6+5.6

Ø19.05(3/4)

Ø41.3(1 5/8)

Ø34.9(1 3/8)

3

64

128.8

144.9

39.85

35.40

3.23

4.09

3, 380~415, 50

(1280x1607x730)x3

285+285+285

63

570

6

8+8+8

5.6+5.6+5.6

Ø19.05(3/4)

Ø41.3(1 5/8)

Ø34.9(1 3/8)

3

64

134.4

151.2

42.0

37.2

3.20

4.06

3, 380~415, 50

(1280x1607x730)x3

285+285+285

63

570

6

8+8+8

5.6+5.6+5.6

Ø19.05(3/4)

Ø41.3(1 5/8)

Ø34.9(1 3/8)

3

64

106.4

119.7

31.13

28.73

3.42

4.17

3, 380~415, 50

(1280x1607x730)x3

240+285+285

63

570

5

8+8+8

5.6+5.6+3.3

Ø19.05(3/4)

Ø41.3(1 5/8)

Ø34.9(1 3/8)

3

61

38ARUB360LT2ARUB140LT2ARUB140LT2ARUB80LT2

ARUB380LT2ARUB160LT2ARUB140LT2ARUB80LT2

ARUB400LT2ARUB160LT2ARUB160LT2ARUB80LT2

ARUB420LT2ARUB160LT2ARUB160LT2ARUB100LT2

ARUB440LT2ARUB160LT2ARUB140LT2ARUB140LT2

ARUB460LT2ARUB160LT2ARUB160LT2ARUB140LT2

ARUB480LT2ARUB160LT2ARUB160LT2ARUB160LT2

DC Inverter Scroll / Constant speed Scroll

Propeller Fan(DC INV)

Warm Gray

Gold finR410A

RatiooftheconnectableindoorunitsLongestpipinglength/Leveldifference**

50~130%

200m/100m

* Specifications22HP

Model Combinationunit Independentunit

Capacity Cooling kW Heating kWPower Cooling kWInput Heating kWCOP Cooling HeatingPowerSupply Ø,V,HzDimensions(WxHxD) mmWeight kgColorNoiselevel dBA±3Fan Type Airflowrate [CMM]Compressor Type NumberofcompressorsHeatExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping Liquid(flare) mm(inch)Connections SuctionGas mm(inch) DischargeGas mm(inch)NumberofoutdoorunitNumberofmaximumconnectableindoorunits*

26 34323028

61.6

69.3

17.13

16.33

3.60

4.24

3, 380~415, 50

(1280x1607x730)x2

240+285

61

380

3

8+8

5.6+3.3

Ø15.88(5/8)

Ø34.9(1 3/8)

Ø28.58(1 1/8)

2

35(44)

72.8

81.9

20.93

19.65

3.48

4.17

3, 380~415, 50

(1280x1607x730)x2

285+285

61

380

4

8+8

5.6+5.6

Ø19.05(3/4)

Ø34.9(1 3/8)

Ø28.58(1 1/8)

2

42(52)

78.4

88.2

23.70

21.20

3.31

4.16

3, 380~415, 50

(1280x1607x730)x2

285+285

61

380

4

8+8

EEV

FVC68D(PVE)

5.6+5.6

Ø19.05(3/4)

Ø34.9(1 3/8)

Ø28.58(1 1/8)

2

45(56)

84.0

94.5

25.85

23.00

3.25

4.11

3, 380~415, 50

(1280x1607x730)x2

285+285

61

380

4

8+8

5.6+5.6

Ø19.05(3/4)

Ø34.9(1 3/8)

Ø28.58(1 1/8)

2

49(60)

89.6

100.8

28.00

24.80

3.20

4.06

3, 380~415, 50

(1280x1607x730)x2

285+285

61

380

4

8+8

5.6+5.6

Ø19.05(3/4)

Ø34.9(1 3/8)

Ø28.58(1 1/8)

2

52(64)

95.2

107.1

26.21

25.38

3.63

4.22

3, 380~415, 50

(1280x1607x730)x3

240+285+285

63

570

5

8+8+8

5.6+5.6+3.3

Ø19.05(3/4)

Ø34.9(1 3/8)

Ø28.58(1 1/8)

3

55

67.2

75.6

19.28

18.13

3.49

4.17

3, 380~415, 50

(1280x1607x730)x2

240+285

61

380

3

8+8

5.6+3.3

Ø15.88(5/8)

Ø34.9(1 3/8)

Ø28.58(1 1/8)

2

39(48)

24ARUB220LT2ARUB140LT2ARUB80LT2

ARUB240LT2ARUB160LT2ARUB80LT2

ARUB260LT2ARUB140LT2ARUB120LT2

ARUB280LT2ARUB140LT2ARUB140LT2

ARUB300LT2ARUB160LT2ARUB140LT2

ARUB320LT2ARUB160LT2ARUB160LT2

ARUB340LT2ARUB140LT2ARUB120LT2ARUB80LT2

DC Inverter Scroll / Constant speed Scroll

Propeller Fan(DC INV)

Warm Gray

Gold finR410A

RatiooftheconnectableindoorunitsLongestpipinglength/Leveldifference**

50~160%

200m/100m

50~130%

* Specifications8HP

Model Combinationunit Independentunit

Capacity Cooling kW Heating kWPower Cooling kWInput Heating kWCOP Cooling HeatingPowerSupply Ø,V,HzDimensions(WxHxD) mmWeight kgColorNoiselevel dBA±3Fan Type Airflowrate [CMM]Compressor Type NumberofcompressorsHeatExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping Liquid(flare) mm(inch)Connections SuctionGas mm(inch) DischargeGas mm(inch)NumberofoutdoorunitNumberofmaximumconnectableindoorunits*

10 2018161412ARUB80LT2ARUB80LT2

ARUB100LT2ARUB100LT2

ARUB120LT2ARUB120LT2

ARUB140LT2ARUB140LT2

ARUB160LT2ARUB160LT2

ARUB180LT2ARUB100LT2ARUB80LT2

ARUB200LT2ARUB120LT2ARUB80LT2

22.4

25.2

5.28

5.73

4.24

4.40

3, 380~415, 50

1280x1607x730

240

58

190

1

8

3.3

Ø9.52(3/8)

Ø19.05(3/4)

Ø15.88(5/8)

1

13(20)

28.0

31.5

7.16

7.33

3.91

4.30

3, 380~415, 50

1280x1607x730

285

58

190

2

8

5.6

Ø9.52(3/8)

Ø22.2(7/8)

Ø19.05(3/4)

1

16(25)

33.6

37.8

9.08

9.05

3.70

4.18

3, 380~415, 50

1280x1607x730

285

58

190

2

8

5.6

Ø12.7(1/2)

Ø28.58(1 1/8)

Ø19.05(3/4)

1

19(30)

39.2

44.1

11.85

10.60

3.31

4.16

3, 380~415, 50

1280x1607x730

285

58

190

2

8

EEV

FVC68D(PVE)

5.6

Ø12.7(1/2)

Ø28.58(1 1/8)

Ø22.2(7/8)

1

23(35)

44.8

50.4

14.00

12.40

3.20

4.06

3, 380~415, 50

1280x1607x730

285

58

190

2

8

5.6

Ø12.7(1/2)

Ø28.58(1 1/8)

Ø22.2(7/8)

1

26(40)

50.4

56.7

12.44

13.06

4.05

4.34

3, 380~415, 50

(1280x1607x730)x2

240+285

61

380

3

8+8

5.6+3.3

Ø15.88(5/8)

Ø28.58(1 1/8)

Ø22.2(7/8)

2

29(36)

56.0

63.0

14.36

14.78

3.90

4.26

3, 380~415, 50

(1280x1607x730)x2

240+285

61

380

3

8+8

5.6+3.3

Ø15.88(5/8)

Ø28.58(1 1/8)

Ø22.2(7/8)

2

32(40)

Propeller Fan(DC INV)

Warm Gray

Gold finR410A

RatiooftheconnectableindoorunitsLongestpipinglength/Leveldifference**

50~200%

200m/100m

50~160%

DC Inverter Scroll DC Inverter Scroll / Constant speed Scroll

Note:

1.Capacitiesarebasedonthefollowingconditions Cooling-Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Heating-Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB

Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WBInterconnecting piping length 7.5m Interconnecting piping length 7.5mLevel difference of zero Level difference of zero

2.Capacitiesarenetcapacities3.Duetoourpolicyofinnovationsomespecificationsmaybechangedwithoutnotification4.EEV:ElectronicExpansionValve

**ConditionalApplicationTomake40~90mofpipelengthafterfirstbranchrefertothepartof“installationofoutdoorunits”inPDB

• A combination operation over 100% cause to reduce each indoor unit capacity

• Combinationratio(50~200%)No. of outdoor unit Connection CapacitySingle unit 200%Double unit 160%Triple unit 130%

CAUTION We can guarantee the operation only within 130% Combination.If you want to connect more than 130% combination, please contact us and discuss the requirement like below.

1) If the operation of indoor unit is more than 130%, low airflow operation is recommended in all the indoor units. 2) If the operation of indoor unit is more than 130%, additional refrigerant is needed according to the headquarter guidance. 3) Over 130%, capacity is same as capacity of 130%, Same remark is valid for power input.

*Thenumberof()meansthenumberofmax.connectableindoorunits,whentheconnectedcapacityofindoorunitsisinthetable below.

Page 18: Multi v Hz R410A)

LG A

ir Conditioners System

34_

35O

utdoor Unit_

MU

LTI V SPACE II

COMFORT & SILENCETheconceptofthebalconyischangedwiththeoutdoorunitthatdoesnotgeneratehotair.LownoiseandvibrationtechnologyofMULTIVSPACEIIensuresaquietenvironment.

•MULTIVSPACEII FrontSuction&FrontDischarge•Rightandleftsideairflowsystem

•Highspeedairdischarging(7~8m/sec)

•Nointerferencebetweeneachfloors(Efficiencyreductionduetohotairbackflow)

HotairBuildingwind

Right outoor unit

Left outoor unit

7m/s7m/s

•MULTIVSPACEII •Conventional QuietOperationThenoiseandvibrationarereducedby-Frontdischarge-Sealedstructureofoutdoorunit

Theindoornoiselevelismaintainedat30~40dBA,asquietasbeinginthelibrary

•Conventional Interference between floors!

No efficiency reduction!

•LGpatents:57items LGPatentForMULTIVSPACEIIAlltechnologiesintheMULTIVSPACEIIwhichmakeitadistinctive,uniqueunithavebeenappliedforpatentsdomesticallyandinternationally.and,someofthemhavealreadybeenregistered.

01 Whole structure (8 items)Air handler structrue (18 items)Separation of suction & discharge (6 items)3-side heat exchange structure (3 items)Louver structure /control (20 items)Electrical part(2 items)

02

03

04

05

06

06

05

04

03

02

01

EconomicandaestheticspacedesignMULTIV

SPACEIIisidealforrefinedandluxuriousliving

spaces.

Enjoyaclean&comfortablelifewithMULTIV.

Page 19: Multi v Hz R410A)

*6HP (ARUN60LR2, ARUN60LL2)*8HP (ARUN80LR2, ARUN80LL2)

LG A

ir Conditioners System

36_

37O

utdoor Unit_

MU

LTI V SPACE II

• DC Inverter Compressor & Fan Motor

• Blackbox Function

• Night Silent Operation

• Pump Down

‘09 New Feature

Note :

1. Capacities are based on the following conditions Cooling-Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Heating-Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB

Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WBInterconnecting piping length 7.5m Interconnecting piping length 7.5mLevel difference of zero Level difference of zero

2. Capacities are net capacities3. Due to our policy of innovation some specifications may be changed without notification4. EEV : Electronic Expansion Valve

1stepsLouver frame

4stepsFan parts

3stepsMechanical parts

2stepsSystem louver

4-Step Modularized Design• Modularized design of the outdoor unit provides simpler installation and maintenance.

• Outdoor unit can be installed according to overall building construction schedule.

• Louver is provided locally

Discharging

Duct

Duct application Fan RPM Control (E.S.P & Noise Control)

• Enhanced installation flexibility (Duct application)

• No need of high static pressure exhaust fan and air guide

• Keeping capacity and noise level as desired

How to set up

Step 1 >4mmAq < ESP < 6mmAq

Step 2 >6mmAq < ESP < 8mmAq

Step 3 >8mmAq < ESP < 10mmAq

Step 4 >10mmAq < ESP < 12mmAq

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 2 3 4 5 6 7 8 9 10 11 12 13 14

- E.S.P control

- Noise control1 2 3 4 5 6 7 8 9 10 11 12 13 14 Low blowing noise

> Max - 100 rpm

Economic and aesthetic space design MULTI V

SPACE II is ideal for refined and luxurious living

spaces.

HPModel Independent unit Capacity Cooling kW Heating kWPower Cooling kWInput Heating kWCOP Cooling kW Heating kWPower Supply Ø, V, HzDimensions(WxHxD) mmWeight kgColorNoise level dBA±3E.S.P range mmAqFan Type Air flow rate [CMM]Compressor Type Number of compressorsHeat ExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping Liquid(flare) mm(inch)Connections Gas(Bazing) mm(inch)Number of outdoor unitNumber of maximum connectable indoor unitsRatio of the connectable indoor unitsLongest piping length / Level difference

16.0

18.0

4.7

4.9

3.40

3.67

3, 380~415, 50

750 x 1790 x 650

200

49

4~12

100

1

5.2

2.3

9.52(3/8)

19.05(3/4)

1

9

* Specifications

6

21.7

23.0

6.7

6.7

3.24

3.43

3, 380~415, 50

750 x 1790 x 650

200

53

4~12

100

1

5.2

2.3

9.52(3/8)

19.05(3/4)

1

13

8ARUN60LR2 (Right Discharge)

ARUN60LL2 (Left Discharge)

ARUN80LR2 (Right Discharge)

ARUN80LL2 (Left Discharge)

Warm Gray

Sirocco Fan

DC INV Scroll

Gold Fin

R410A

EEV

FVC68D(PVE)

50~130%

150m/50m

* Preliminary data (8HP model)

Page 20: Multi v Hz R410A)

LG A

ir Conditioners System

38_

39Indoor U

nit

Wall mounted

ARTCOOL

Ceiling Cassette

Ceiling Concealed Duct

Ceiling & Floor

Ceiling Suspended

Floor standing

49505256606162

M U LT I V i n d o o r

If you need a highly efficient air conditioning system in your building, MULTI V is the right choice for you.

Indoor unit

Wall Mounted

Mirror

4Way Casstte

2Way Casstte

1Way Casstte

Low Static

Built-in

High Static

Ceiling & Floor

Ceiling Suspended

Floor Standing- With Case

Floor Standing- Without Case

Page 21: Multi v Hz R410A)

LG A

ir Conditioners System

40

_4

1Indoor U

nit

Aesthetic DesignYou no longer have to be told what your air conditioner should look like. With LG’s revolutionary ARTCOOL photo changeable, you can simply change the look of your air conditioner to what you want, when you want to.

ARTCOOL series with outstanding designs have received International Forum Design Award,

Reddot Design Award and G Mark.

Silver 07/09/12GSFV2 Gold 07/09/12GSFG2 Red 07/09/12GSFE2

Low NoiseSuper light BLDC motor guarantees your enhanced comfortable indoor environment.

Typing Office Conversation Library 4 way CST

- How to change the picture

- Panel type

- ARTCOOL Mirror

Auto Elevation GrilleEasy filter cleaning with elevation grille

- Installed inside main body- Auto horizontal level- 4 points support- Memory for user’s level- Max. 4.5m length

4 Way4.5m

Conventional3.5m

4-Point support structure Auto horizontal control

STOP

Memory

Memory for user’s level Auto bottom detection

Max

. 4.5

mSilver 07/09/12/15GSEV2 18/24GS8V2

Mirror 07/09/12/15GSER2 18/24GS8R2

Blue 07/09/12/15GSEB2 18/24GS8B2

• Aesthetic Design

• Low Noise

• 4 Vane Independent Operation

• Auto Elevation Grille

LG has been able to create a design conscious indoor unit that compliments any interior decoration. And they have improved air flow innovatively to realize world’s lowest noise, and provide a more pleasant and convenient indoor environment.

White silver 07/09/12GSFH2

4 Vanes Independent OperationVane angle control satisfies both users who like direct wind and indirect wind. and also it prevents cold air draft.

1 Vane, 1 Motor

1 : 20 °

0 : 30 °

2 : 40 °

3 : 50 ° 4 : 60 °5 : 70 °

All vane operation Individual vane operation

Air flow rate control Individual vane angel control

• Easy vane angle control with a remote controller

Direct air flow Indirect air flow

*Available for 24k ~ 48k Btu/h

Page 22: Multi v Hz R410A)

LG A

ir Conditioners System

42_

43

Indoor Unit

High Ceiling ModeHigh ceiling mode with phase-control algorithm is possible to apply as high as 3.6m of ceiling.

4 way CSTConventional

Wide Jet VaneImproved wide and narrow vane will provide comfortable temperature distribution withoutair flow dead zone.

80mm Wider!! 567mm

487mm

NEW

Current

Even air distributiont262524232221201918

27°CTemp.

15°C

Highlander

Air flow dead zonet262524232221201918

27°CTemp.

15°C

Current

• Air flow improvement

Flexible ConnectionFlexible connection of remote controller

- Group control : 1 remote controller to several indoor units

- Second remote control : 2 remote controllers to 1 indoor unit

Easy & solid attachment to the wall wall

wall

Application of Ceiling Concealed DuctIt is possible to make each rooms cool & warm with installing a chamber and a spiral duct.

Max. 9 discharging

Linear E.S.P ControlAir volume and sound are always kept as design regardless of E.S.P changeusing this technology , you can

• Optimize duct work Installation• Keep capacity & sound level as desired• Simplify model numbers

The phase control motor technology offers money saving benefit to the installer.

*E.S.P is easily controlled by remote controller

Application of Built-in DuctBuilt-in duct has no need of duct space with using suction canvas and grille.

CanvasGrille

• Wide Jet Vane

• High Ceiling Mode

• Flexible Connection

• Appliaction of Ceiling Concealed Duct

• Appliaction of Built-in Duct

• Linear E.S.P Control

LG has been able to create a design conscious indoor unit that compliments any interior decoration. And they have improved air flow innovatively to realize world’s lowest noise, and provide a more pleasant and convenient indoor environment.

* For 4 way cassette (570 * 570), this function will be applied from May.

Page 23: Multi v Hz R410A)

LG A

ir Conditioners System

44

_4

5Indoor U

nit

Drain hose Drain pump

One Touch Type PanelIt provides easy installation with a one-touch detachable panel.

Compact SizeThe indoor unit with slim and compact size has reduced the restriction which enables successful installation in various spaces.

LG conventional

204mm

218mm

246mm

288mm

6.0 ~ 7.2 kW 8.3 ~ 11.0 kW

Back

Side Floor

Sliding Type FilterEasy maintenance and extended product life with sliding type anti-biotic filter.

Sliding type

Anti-biotic filter Easy cleaning

Convenient InstallationEasy installation with corner detachable decoration panel.

• Coner detachable design

Drain leakage check

Refrigerantpiping check

Hanger adjust Hanger adjust

• Compact Size

• One Touch Type Panel

• Convenient Installation

• Easy Drain Installation

• 3Way Flexible Installation

• Sliding Type Filter

LG has been able to create a design conscious indoor unit that compliments any interior decoration. And they have improved air flow innovatively to realize world’s lowest noise, and provide a more pleasant and convenient indoor environment.

Drain leakage check Hanger adjust

Easy Drain InstallationIt reduces the installation time by over 40% with elbow-less drain hose.

Midget drain pump covers maximum 800mm high, featuring easy piping installation.

3Way Flexible InstallationAll sides (front, back, floor) are possibleto install and connect to the outdoor unit.

* Accessory (Drain hose) PHDHA05T – 500mm 30EA PHDHA07T - 700mm 30EA PHDHA05B – 500mm 5EA PHDHA07B – 700mm 5EA

Page 24: Multi v Hz R410A)

LG A

ir Conditioners System

46

_4

7Indoor U

nit

Digital Air Flow ControlThe air flow can be controlled to ensure maximum comfort and convenience.

Normal fast & even widely

Jet cool speedy & powerful

Sleep mode indirectly & softly

Neo Plasma Air Purifying SystemLG’s unique NEO Plasma air purifying system is equipped with 7 specialized filters in 5 separate stages to enhance its cleaning power. It reduces fine dust and mold, unpleasant odors and cigarette smoke as air passes through each filter.

Swirl swing (plaesant air) Normal air flow

Vertical Temp. differences Horizontal Temp. differences

• Comparison of temperatures

Swirl SwingSwirl swing distributes air evenly throughout the room to ensure a more comfortable conditioned environment by adjusting the movement of the vane.

Nano Bio Fusion Filter

Nano bio fusion filters allow their nanosize bio enzymes to directly penetrate through cell walls of some bacteria and allergen to decompose its cell nuclei.

* Test Result Certification

Distinctions from Conventional Filters

The bio enzyme destroys cell walls and nuclei of some bacteria and allergens.

• Nano Bio Fusion Filter

• Conventional

Simply inactivatebacteria

Destroy bacteria but allowpart of them to survive

Pre Filter

The antibacterial pre-filter primarily reduces large dust, mold and quilt dust.

01

Nano Carbon Filter

Nano-size carbon filters remove fine odorous particles from the household air resulting in a more pleasant environment.

What is Nano Carbon Ball?Microscopic sized (1/1000000000) filter to ensure optimal filtration of odors.

200~500nm

02

Triple Filter

The triple filter consists of three specialized filters to reduce the symptoms associated with various organic compounds including formaldehyde. It also has the ability to reduce unpleasant odors creating a more comfortable environment.

03

04

Plasma Filter

The PLASMA Air Purifying System developed uniquely by LG not only reduces microscopic contaminants and dust, but also reduces house mites, pollen, and pet fur to reduce allergy and asthma symptoms.

05

Bio Active Site

NanoParticle

Active State Bacteria Selective Capture

Bacteriolysis Regeneration(Active State)

NanoParticle

NanoParticle

NanoParticle

Bacteria, Virus

Clean AirPolluted Air

01 02 03 04 05

Odor Free! Dust Free! Allergy Free!

LG has been able to create a design conscious indoor unit that compliments any interior decoration. And they have improved air flow innovatively to realize world’s lowest noise, and provide a more pleasant and convenient indoor environment.

• Neo Plasma Air Purifying System

• Digital Air Flow Control

• Swirl Swing

• Child Lock Function

Healthy DehumidificationDehumidification mode reducesuncomfortable humidity from theroom without over cooling.

LG Healthy DehumidificationBy increasing the vane angle, a better approach of the actual temperature is possible to prevent over cooling.

ConventionalSince the surrounding temperature is measured after the air from the unit is widely distributed, accurate approach of the air is not possible.

Indoor Temperature Distribution Chart

Page 25: Multi v Hz R410A)

LG A

ir Conditioners System

48

_4

9Indoor U

nit

Weekly ProgramThe operator can set an on/off reservation of the air conditioner for a period of one week.

LCD Wired Remote Controller• On/Off• Test run mode• Self-diagnosis• 3-step fan speed selection• Operation indication• Room temperature

Auto CleanAuto clean helps to remove odor and save clean-up time. After using airconditioner, “Auto clean” makes the inner part of Air conditioner dry for 30 min. It removes mositure and mold so you can enjoy odor-free air and save time to clean up.

LG Auto Clean Conventional

Dries the evaporator with gentle low noise air from the fan by removing any remaining moisture.Pressing the Auto Clean button will activate the automatic cleaning function after the cooling operation.

1 STEP

Removes moulds through the neo plasma system.Only the fan will operate to dry the inner part of the air conditioner in just 30 minutes.

2 STEP

Air Flow Direction ControlHorizontal airflow control- Adjust the horizontal airflow direction by manually moving the horizontal airflow direction vane by hand.

Vertical airflow- The airflow direction can be adjusted as desired by using the remote controller.

Horizontal airflow control Vertical airflow control

ARNU07GSEL2 / ARNU09GSEL2ARNU12GSEL2 / ARNU15GSEL2ARNU18GS5L2 / ARNU24GS5L2

Wall Mounted

LG has been able to create a design conscious indoor unit that compliments any interior decoration. And they have improved air flow innovatively to realize world’s lowest noise, and provide a more pleasant and convenient indoor environment.

Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions(WxDxH) mmWeight kgNoise level dBA±3Air flow rate H/M/L CMMNeo Plasma air purifying filterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm

Model Unit ARNU07GSEL2 ARNU12GSEL2 ARNU24GS5L2ARNU09GSEL2 ARNU18GS5L2

1, 220~240, 50

ARNU15GSEL2

* Specifications

2.27,500

2.58,500

4040

937 / 33 / 235.6 / 5 / 4.6

oØ6.35(1/4)Ø12.7(1/2)

20/16

3.612,300

4.013,600

4040

941 / 36 / 279.5 / 9 / 8.5

oØ6.35(1/4)Ø12.7(1/2)

20/16

7.124,200

8.027,300

4040

1246 / 41 / 3814 / 13 / 10

oØ9.52(3/8)

Ø15.88(5/8)20/16

2.89,600

3.210,900

4040

939 / 35 / 257 / 6.5 / 6

oØ6.35(1/4)Ø12.7(1/2)

20/16

5.619,100

6.321,500

4040

1244 / 40 / 3612 / 10.5 / 9

oØ6.35(1/4)Ø12.7(1/2)

20/16

4.515,400

5.017,100

4040

942 / 36 / 27

10.5 / 9 / 8.5o

Ø6.35(1/4)Ø12.7(1/2)

20/16

895x165x282 1090x178x300

* AccessoriesModel

Dry ContactPQDSA

PQDSB/ PQDSB1PQDSBC

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

ARNU07GSEL2 ARNU12GSEL2 ARNU24GS5L2ARNU09GSEL2 ARNU18GS5L2ARNU15GSEL2

Wired remote controller Wireless remote controller

Deluxe type

PQRCUDS0*Standard type

PQRCUSA1 Simple type

PQRCUCS0C Simple type for hotel

PQRCFCS0C PQWRHDF0

SUNDAY

MONDAY

TUESDAY

WEDNESDAY

THURSDAY

FRIDAY

SATURDAY

Note :

1. Capacities are based on the following conditions Cooling-Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Heating-Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Interconnecting piping length 7.5m Level difference of zero Level difference of zero2. Due to our policy of innovation some specifications may be changed without notification

Page 26: Multi v Hz R410A)

Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPowerSupply Ø,V,HzDimensions(WxDxH) mmWeight kgNoiselevel dBA±3Airflowrate H/M/L CMMNeoPlasmaairpurifyingfilterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm

LG A

ir Conditioners System

50_

51Indoor U

nit_ARTCO

OL G

allery / Mirror

ARNU07GSF*2 / ARNU09GSF*2ARNU12GSF*2

* SpecificationsModel Unit ARNU07GSF*2 ARNU09GSF*2 ARNU12GSF*2

2.27,500

2.58,500

3535

1538 / 32 / 27

8.1 / 6.3 / 4.2o

Ø6.35(1/4)Ø12.7(1/2)16.2/12.2

2.89,600

3.210,900

3535

1, 220~240, 50600x146x600

1538 / 32 / 27

8.1 / 6.3 / 4.2o

Ø6.35(1/4)Ø12.7(1/2)16.2/12.2

3.612,300

4.013,600

3535

1544 / 38 / 32

9.3 / 7.7 / 6.0o

Ø6.35(1/4)Ø12.7(1/2)16.2/12.2

* AccessoriesModel

DryContactPQDSA

PQDSB/PQDSB1PQDSBC

ARNU07GSF*2 ARNU09GSF*2 ARNU12GSF*2

Withoutcase(1contactpoint)Withcase(1contactpoint)Withcase(2contactpoint)

Silver Gold

Red WhiteSilver

*1:Photochangeable,V:Silver,E:Red,G:Gold,H:WhiteSilver

*Photochangeable

Wiredremotecontroller Wirelessremotecontroller

Deluxetype

PQRCUDS0*Standardtype

PQRCUSA1Simpletype

PQRCUCS0CSimpletypeforhotel

PQRCFCS0C PQWRHDF0

*Checkupthenote,refertoonthe49page.

*Paneltype

MirrorARNU07GSE*2 / ARNU09GSE*2 / ARNU12GSE*2 ARNU15GSE*2 / ARNU18GS8*2 / ARNU24GS8*2

Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPowerSupply Ø,V,HzDimensions(WxDxH) mmWeight kgNoiselevel dBA±3Airflowrate H/M/L CMMNeoPlasmaairpurifyingfilterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm

Model Unit ARNU07GSE*2

* Specifications

1170x173x315

ARNU09GSE*2 ARNU12GSE*2 ARNU18GS8*2 ARNU24GS8*2

1, 220~240, 50

ARNU15GSE*2

* AccessoriesModel

DryContactPQDSA

PQDSB/PQDSB1PQDSBC

Withoutcase(1contactpoint)Withcase(1contactpoint)Withcase(2contactpoint)

ARNU07GSE*2 ARNU09GSE*2 ARNU12GSE*2 ARNU15GSE*2 ARNU24GS8*2ARNU18GS8*2

2.27,500

2.58,500

4040

11.237 / 33 / 23

7 / 6 / 4 o

Ø6.35(1/4)Ø12.7(1/2)

20/16

2.89,600

3.210,900

4040

11.239 / 35 / 25

8 / 7 / 5 o

Ø6.35(1/4)Ø12.7(1/2)

20/16

3.612,300

4.013,600

4040

11.241 / 36 / 27

10 / 8 / 6 o

Ø6.35(1/4)Ø12.7(1/2)

20/16

5.619,100

6.321,500

4040

1337 / 34 / 31

14.4 / 13 / 11 o

Ø6.35(1/4)Ø12.7(1/2)

20/16

7.124,200

8.027,300

4040

1343 / 37 / 32

17.9 / 14.4 / 12 o

Ø9.52(3/8)Ø15.88(5/8)

20/16

4.515,400

5.017,100

4040

11.242 / 36 / 2710.5 / 8 / 6

oØ6.35(1/4)Ø12.7(1/2)

20/16

915x169x282

Wiredremotecontroller Wirelessremotecontroller

Deluxetype

PQRCUDS0*Standardtype

PQRCUSA1Simpletype

PQRCUCS0CSimpletypeforhotel

PQRCFCS0C PQWRHDF0

Silver

Mirror

Blue

*R:Mirror,B:Blue,V:Silver

*Checkupthenote,refertoonthe49page.*Preliminarydata(18~24kmodel)

Page 27: Multi v Hz R410A)

LG A

ir Conditioners System

52_53

Indoor Unit_

Ceiling Cassette

ARNU05GTRC2 / ARNU07GTRC2ARNU09GTRC2 / ARNU12GTRC2ARNU15GTQC2 / ARNU18GTQC2

ARNU24GTPC2 / ARNU28GTPC2ARNU36GTNC2 / ARNU42GTMC2 ARNU48GTMC2

4 Way Cassette (570*570) 4 Way Cassette (840*840)

Wired remote controller Wireless remote controller

Deluxe type

PQRCUDS0*Standard type

PQRCUSA1 Simple type

PQRCUCS0C Simple type for hotel

PQRCFCS0C PQWRHDF0

Wired remote controller Wireless remote controller

Deluxe type

PQRCUDS0*Standard type

PQRCUSA1 Simple type

PQRCUCS0C Simple type for hotel

PQRCFCS0C PQWRHDF0

Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions Body mm(WxDxH) Front panel mmWeight Body kg Front panel Panel ColorNoise level dBA±3Air flow rate H/M/L CMMNeo Plasma air purifying filterDrain PumpPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm

* SpecificationsModel Unit

5.619,100

6.321,500

4545

15.52.5

38 / 37 / 3611.2 / 11 / 10

oo

Ø6.35(1/4)Ø12.7(1/2)

32/25

2.27,500

2.58,500

4545

13.12.3

36 / 35 / 337.5 / 7 / 6.6

oo

Ø6.35(1/4)Ø12.7(1/2)

32/25

2.89,600

3.210,900

4545

14.22.3

36 / 35 / 348 / 7.5 / 7.1

o o

Ø6.35(1/4)Ø12.7(1/2)

32/25

3.612,300

4.013,600

4545

14.22.3

36 / 35 / 348.7 / 8 / 7

oo

Ø6.35(1/4)Ø12.7(1/2)

32/25

4.515,400

5.017,100

4545

15.52.5

37 / 36 / 3511 / 10 / 9.3

oo

Ø6.35(1/4)Ø12.7(1/2)

32/25

1, 220 ~ 240, 50570 x 570 x 214

700x700x30

Morning Fog

* Check up the note, refer to on the 49 page.

1.65,500

1.86,100

4545

13.12.3

36 / 35 / 337.5 / 7 / 6.6

oo

Ø6.35(1/4)Ø12.7(1/2)

32/25

ARNU07GTRC2 ARNU09GTRC2 ARNU12GTRC2 ARNU18GTQC2ARNU15GTQC2ARNU05GTRC2

570 x 570 x 256

* AccessoriesModel

Dry ContactPQDSA

PQDSB/ PQDSB1

PQDSBC

PT-UQC

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

Front Panel

ARNU07GTRC2 ARNU09GTRC2 ARNU12GTRC2 ARNU18GTQC2ARNU15GTQC2ARNU05GTRC2

Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions Body mm(WxDxH) Front Panel mmWeight Body kg Front Panel kgPanel ColorNoise level dBA±3Air flow rate H/M/L CMMNeo Plasma air purifying filterDrain PumpPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm

* SpecificationsARNU28GTPC2 ARNU36GTNC2 ARNU42GTMC2 ARNU48GTMC2

8.228,000

9.231,500

3333

20.84.5

39 / 38 / 3219 / 16 / 14

oo

Ø9.52(3/8)Ø15.88(5/8)

32/25

10.636,200

11.940,600

144144

23.54.5

43 / 40 / 3925 / 21 / 19

oo

Ø9.52(3/8)Ø15.88(5/8)

32/25

12.342,000

13.843,800

144144

25.64.5

47 / 44 / 4230 / 27 / 24

oo

Ø9.52(3/8)Ø15.88(5/8)

32/25

14.148,100

15.951,200

144144

25.64.5

48 / 47 / 4531 / 29 / 27

oo

Ø9.52(3/8)Ø15.88(5/8)

32/25

Model Unit7.1

24,2008.0

27,3003333

20.84.5

38 / 35 / 3117 / 15 / 13

oo

Ø9.52(3/8)Ø15.88(5/8)

32/25

950x950x25

ARNU24GTPC2

840x840x204 840x840x2881, 220 ~ 240, 50

840x840x246

Morning Fog

* Check up the note, refer to on the 49 page.

* AccessoriesModel

Dry ContactPQDSA

PQDSB/ PQDSB1PQDSBCPT-UMCPTEGM0

PTVK410 / PTVK420 / PTVK 430

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

ARNU28GTPC2 ARNU36GTNC2 ARNU42GTMC2 ARNU48GTMC2ARNU24GTPC2

Front PanelAuto Elevation GrilleVentilation Kit

Page 28: Multi v Hz R410A)

Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions Body mm(WxDxH) Front Panel mmWeight Body kg Front Panel kgPanel ColorNoise level dBA±3Air flow rate H/M/L CMMNeo Plasma air purifying filterDrain PumpPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm

LG A

ir Conditioners System

54_

55Indoor U

nit_Ceiling Cassette

ARNU18GTLC2 / ARNU24GTLC2 ARNU07GTJC2 / ARNU09GTJC2ARNU12GTJC2

* Specifications

7.124,200

8.027,300

7070

224

42 / 37 / 3217 / 15 / 13

oo

Ø9.52(3/8)Ø15.88(5/8)

32/25

Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions Body mm(WxDxH) Front Panel mmWeight Body kg Front Panel kgPanel ColorNoise level dBA±3Air flow rate H/M/L CMMNeo Plasma air purifying filterDrain PumpPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm

Model Unit5.6

19,1006.3

21,5007070

224

40 / 35 / 3013 / 12 / 10

oo

Ø6.35(1/4)Ø12.7(1/2)

32/25

ARNU18GTLC2 ARNU24GTLC2

1, 220 ~ 240, 50830x550x225

1050x640x28.5

* SpecificationsModel Unit

3.612,300

4.013,600

4040

11.51.5

41 / 39 / 378 / 7 / 6

o o

Ø6.35(1/4)Ø12.7(1/2)

32/25

2.27,500

2.58,500

4040

11.51.5

40 / 38 / 377.5 / 6.5 / 6

oo

Ø6.35(1/4)Ø12.7(1/2)

32/25

2.89,600

3.210,900

4040

11.51.5

40 / 38 / 377.5 / 6.5 / 6

oo

Ø6.35(1/4)Ø12.7(1/2)

32/25

ARNU07GTJC2 ARNU09GTJC2 ARNU12GTJC2

1, 220 ~ 240, 50860x410x1381070x480x20

Morning Fog

2 Way Cassette 1 Way Cassette

* AccessoriesModel

Dry ContactPQDSA

PQDSB/ PQDSB1

PQDSBC

PT-HLC

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

ARNU18GTLC2 ARNU24GTLC2

Front panel

* AccessoriesModel

Dry ContactPQDSA

PQDSB/ PQDSB1

PQDSBC

PT-HJC

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

Front panel

ARNU07GTJC2 ARNU09GTJC2 ARNU12GTJC2

Morning Fog

Wired remote controller Wireless remote controller

Deluxe type

PQRCUDS0*Standard type

PQRCUSA1 Simple type

PQRCUCS0C Simple type for hotel

PQRCFCS0C PQWRHDF0

Wired remote controller Wireless remote controller

Deluxe type

PQRCUDS0*Standard type

PQRCUSA1 Simple type

PQRCUCS0C Simple type for hotel

PQRCFCS0C PQWRHDF0

* Check up the note, refer to on the 49 page. * Check up the note, refer to on the 49 page.

Page 29: Multi v Hz R410A)

Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPowerSupply Ø,V,HzDimensions(WxDxH) mmSuctiongrille(WxDxH)Suctioncanvas(WxHxD)Weight kgNoiselevel dBA±3E.S.Prange mmAqAirflowrate H/M/L CMMNeoPlasmaairpurifyingfilterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm

LG A

ir Conditioners System

56_

57Indoor U

nit_Ceiling Concealed D

uct

ARNU07GB1G2 / ARNU09GB1G2ARNU12GB1G2 / ARNU15GB1G2ARNU18GB2G2 / ARNU24GB2G2

ARNU07GB3G2 / ARNU09GB3G2ARNU12GB3G2 / ARNU15GB3G2ARNU18GB4G2 / ARNU24GB4G2

* Specifications

Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPowerSupply Ø,V,HzDimensions(WxDxH) mmWeight kgNoiselevel dBA±3E.S.PrangemmAqAirflowrate H/M/L CMMNeoPlasmaairpurifyingfilterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm

Model Unit ARNU07GB1G2 ARNU09GB1G2 ARNU12GB1G2 ARNU18GB2G2 ARNU24GB2G2ARNU15GB1G2

* SpecificationsModel Unit ARNU07GB3G2 ARNU09GB3G2 ARNU12GB3G2 ARNU18GB4G2 ARNU24GB4G2ARNU15GB3G2

Low Static Duct Built-in Duct

* AccessoriesModel

DryContactPQDSA

PQDSB/PQDSB1

PQDSBC

Withoutcase(1contactpoint)Withcase(1contactpoint)Withcase(2contactpoint)

ARNU07GB1G2 ARNU09GB1G2 ARNU12GB1G2 ARNU18GB2G2 ARNU24GB2G2ARNU15GB1G2

* AccessoriesModel

DryContactPQDSA

PQDSB/PQDSB1

PQDSBC

Withoutcase(1contactpoint)Withcase(1contactpoint)Withcase(2contactpoint)

ARNU07GB3G2 ARNU09GB3G2 ARNU12GB3G2 ARNU18GB4G2 ARNU24GB4G2ARNU15GB3G2

SuctionGrilleSuctionCanvas

PBSGB30PBSC30

PBSGB40PBSC40

2.27,500

2.58,500

3030

2135 / 33 / 31

8.5 / 7.5 / 6.5-

Ø6.35(1/4)Ø12.7(1/2)

32/25.4

2.89,600

3.210,900

3030

2136 / 35 / 33

9.5 / 8.5 / 7.5-

Ø6.35(1/4)Ø12.7(1/2)

32/25.4

3.612,300

4.013,600

3030

2137 / 36 / 35

10.5 / 9.5 / 8.5-

Ø6.35(1/4)Ø12.7(1/2)

32/25.4

5.619,100

6.321,500

8080

2640 / 37 / 34

16 / 14 / 12-

Ø6.35(1/4)Ø12.7(1/2)

32/25.4

7.124,200

8.027,300

8080

2643 / 40 / 37

19 / 17 / 15-

Ø9.52(3/8)Ø15.88(5/8)

32/25.4

4.515,400

5.017,100

3030

2138 / 37 / 36

11.5 / 10.5 / 9.5-

Ø6.35(1/4)Ø12.7(1/2)

32/25.4

1, 220 ~ 240, 50

0~4

1100x575x190820x575x190

2.27,500

2.58,500

3030

2137 / 34 / 33

8 / 6.5 / 5.5-

Ø6.35(1/4)Ø12.7(1/2)

32/25.4

2.89,600

3.210,900

3030

2139 / 35 / 34

9 / 7 / 6-

Ø6.35(1/4)Ø12.7(1/2)

32/25.4

3.612,300

4.013,600

3030

2140 / 37 / 34

10 / 8 / 6.5-

Ø6.35(1/4)Ø12.7(1/2)

32/25.4

5.619,100

6.321,500

8080

2643 / 40 / 37

14 / 12 / 10-

Ø6.35(1/4)Ø12.7(1/2)

32/25.4

7.124,200

8.027,300

8080

2646 / 43 / 37

17 / 15 / 10-

Ø9.52(3/8)Ø15.88(5/8)

32/25.4

4.515,400

5.017,100

3030

2141 / 40 / 37

11 / 10 / 8-

Ø6.35(1/4)Ø12.7(1/2)

32/25.4

820x575x1901, 220~ 240, 50

910x359x56821x274x(45~250) 1100x274x(45~250)

1188x359x561100x575x190

0~4

Wiredremotecontroller Wirelessremotecontroller

Deluxetype

PQRCUDS0*Standardtype

PQRCUSA1Simpletype

PQRCUCS0CSimpletypeforhotel

PQRCFCS0C PQWRHDF0

Wiredremotecontroller Wirelessremotecontroller

Deluxetype

PQRCUDS0*Standardtype

PQRCUSA1Simpletype

PQRCUCS0CSimpletypeforhotel

PQRCFCS0C PQWRHDF0

*Forusingwirelessremotecontroller,itneedstoinstallstandardwiredremotecontroller.(Duct,Floorstandingmodel.)*Forusingwirelessremotecontroller,itneedstoinstallstandardwiredremotecontroller.(Duct,Floorstandingmodel.)

*Checkupthenote,refertoonthe49page.

*Checkupthenote,refertoonthe49page.

Page 30: Multi v Hz R410A)

LG A

ir Conditioners System

58_

59Indoor U

nit_Ceiling Concealed D

uct

ARNU07GBHA2 / ARNU09GBHA2ARNU12GBHA2 / ARNU15GBHA2ARNU18GBHA2 / ARNU24GBHA2

* Specifications

Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions(WxDxH) mmWeight kgNoise level dBA±3E.S.P range mmAqAir flow rate H/M/L CMMNeo Plasma air purifying filterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm

Model Unit ARNU07GBHA2 ARNU09GBHA2 ARNU12GBHA2 ARNU15GBHA2 ARNU18GBHA2 ARNU24GBHA2

ARNU28GBGA2 / ARNU36GBGA2ARNU42GBGA2 / ARNU48GBRA2URNU76GB8A2 / URNU96GB8A2

* Specifications

Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions(WxDxH) mmWeight kgNoise level dBA±3E.S.P range mmAqAir flow rate H/M/L CMMNeo Plasma air purifying filterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm

Model Unit ARNU28GBGA2 ARNU36GBGA2 ARNU42GBGA2 ARNU48GBRA2 URNU76GB8A2 URNU96GB8A2

1, 220 ~240, 501182x450x298

High Static Duct High Static Duct

* AccessoriesModel

Dry ContactPQDSA

PQDSB/ PQDSB1

PQDSBC

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

ARNU28GBGA2 ARNU36GBGA2 ARNU42GBGA2 ARNU48GBRA2 URNU76GB8A2 URNU96GB8A2

* AccessoriesModel

Dry ContactPQDSA

PQDSB/ PQDSB1

PQDSBC

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

ARNU07GBHA2 ARNU09GBHA2 ARNU12GBHA2 ARNU15GBHA2 ARNU18GBHA2 ARNU24GBHA2

5.619,100

6.321,500

150150

26.542.5 / 41 / 37

15.5 / 13.5 / 12.4-

Ø6.35(1/4)Ø12.7(1/2)

32/25

7.124,200

8.027,300

150150

26.545 / 43 / 41

18.3 / 16.9 / 15.5-

Ø9.52(3/8)Ø15.88(5/8)

32/25

2.27,500

2.58,500150150

2634 / 33 / 32

8.5 / 7.5 / 6-

Ø6.35(1/4)Ø12.7(1/2)

32/25

2.89,600

3.210,900

150150

2635 / 34 / 33

10 / 8.5 / 7.5-

Ø6.35(1/4)Ø12.7(1/2)

32/25

3.612,300

4.013,600

150150

2637 / 35 / 34

12 / 10 / 8.5-

Ø6.35(1/4)Ø12.7(1/2)

32/25

4.515,400

5.017,100

150150

2639 / 38 / 37

13.5 / 12 / 8.5-

Ø6.35(1/4)Ø12.7(1/2)

32/25

8.228,000

9.231,500

450450

3844 / 42 / 40

6~1625.9 / 24.1 / 21.8

-Ø9.52(3/8)

Ø15.88(5/8)32/25

12.342,000

13.843,800

450450

3848 / 46 / 45

6~1234.5 / 32.3 / 30.7

-Ø9.52(3/8)

Ø15.88(5/8)32/25

14.148,100

15.951,200

450450

5345 / 43 / 41

7~2044.8 / 40.6 / 33.3

-Ø9.52(3/8)

Ø15.88(5/8)32/25

10.636,200

11.940,600

450450

3846 / 44 / 42

6~1432.3 / 29 / 25.3

-Ø9.52(3/8)

Ø15.88(5/8)32/25

22.476,400

25.286,000

800800

8750 / 48 / 48

64 / 50 / 50

-Ø9.52(3/8)

Ø19.05(3/4)32/25

28.095,900

31.5107,500

800800

8752 / 50 / 50

72 / 64 / 64

-Ø9.52(3/8)Ø22.2(7/8)

32/25

1, 220 ~240, 50882x450x260

4~12

1562x688x4601230x590x380

12-25

Wired remote controller Wireless remote controller

Deluxe type

PQRCUDS0*Standard type

PQRCUSA1 Simple type

PQRCUCS0C Simple type for hotel

PQRCFCS0C PQWRHDF0

Wired remote controller Wireless remote controller

Deluxe type

PQRCUDS0*Standard type

PQRCUSA1 Simple type

PQRCUCS0C Simple type for hotel

PQRCFCS0C PQWRHDF0

* For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.)* For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.)

* Check up the note, refer to on the 49 page. * Check up the note, refer to on the 49 page.

Page 31: Multi v Hz R410A)

LG A

ir Conditioners System

60

_6

1Indoor U

nit_Ceiling &

Floor / Ceiling Suspended

ARNU09GVEA2 / ARNU12GVEA2 ARNU18GVJA2 / ARNU24GVJA2

* Specifications

Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions(WxDxH) mmWeight kgNoise level dBA±3Air flow rate H/M/L CMMPlasma air purifying filterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm

Model Unit ARNU09GVEA2 ARNU12GVEA22.8

9,6003.2

10,9003030

13.7 36 / 32 / 28

7.6 / 6.9 / 6.2-

Ø6.35(1/4)Ø12.7(1/2)

20/16

3.612,300

4.013,600

3030

13.7 38 / 36 / 30

9.2 / 7.6 / 6.9-

Ø6.35(1/4)Ø12.7(1/2)

20/16

1, 220 ~ 240, 50900x200x490

* Specifications

Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions(WxDxH) mmWeight kgNoise level dBA±3Air flow rate H/M/L CMMNeo Plasma air purifying filterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm

Model Unit ARNU18GVJA2 ARNU24GVJA25.6

19,1006.3

21,5006363

24.642 / 40 / 3716 / 14 / 12

-Ø6.35(1/4)Ø12.7(1/2)

20/16

7.124,200

8.027,300

6363

24.643 / 41 / 3918 / 16 / 14

-Ø9.52(3/8)

Ø15.88(5/8)20/16

1, 220~240, 50950x220x650

Ceiling & Floor Ceiling Suspended

* AccessoriesModel

Dry ContactPQDSA

PQDSB/ PQDSB1

PQDSBC

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

ARNU09GVEA2 ARNU12GVEA2

* AccessoriesModel

Dry ContactPQDSA

PQDSB/ PQDSB1

PQDSBC

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

ARNU18GVJA2 ARNU24GVJA2

Wired remote controller Wireless remote controller

Deluxe type

PQRCUDS0*Standard type

PQRCUSA1 Simple type

PQRCUCS0C Simple type for hotel

PQRCFCS0C PQWRHDF0

Wired remote controller Wireless remote controller

Deluxe type

PQRCUDS0*Standard type

PQRCUSA1 Simple type

PQRCUCS0C Simple type for hotel

PQRCFCS0C PQWRHDF0

* Check up the note, refer to on the 49 page. * Check up the note, refer to on the 49 page.

Page 32: Multi v Hz R410A)

LG A

ir Conditioners System

62_

63

Indoor Unit_

Floor Standing

ARNU07GCEA2 / ARNU09GCEA2ARNU12GCEA2 / ARNU15GCEA2ARNU18GCFA2 / ARNU24GCFA2

ARNU07GCEU2 / ARNU09GCEU2ARNU12GCEU2 / ARNU15GCEU2ARNU18GCFU2 / ARNU24GCFU2

Floor Standing with case

Floor Standing without case

* AccessoriesModel

Dry ContactPQDSA

PQDSB/ PQDSB1PQDSBC

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

ARNU07GCEA2 ARNU18GCFA2ARNU09GCEA2 ARNU12GCEA2 ARNU24GCFA2ARNU15GCEA2

* AccessoriesModel

Dry ContactPQDSA

PQDSB/ PQDSB1

PQDSBC

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

ARNU24GCFU2ARNU07GCEU2 ARNU18GCFU2ARNU09GCEU2 ARNU12GCEU2 ARNU15GCEU2

* For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.)* For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.)

* Specifications

Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions(WxDxH) mmWeight kgNoise level dBA±3Air flow rate H/M/L CMMPlasma air purifying filterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(ID) mm

Model Unit ARNU07GCEA2 ARNU18GCFA2ARNU09GCEA2 ARNU12GCEA2 ARNU24GCFA2ARNU15GCEA2

* Specifications

Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions(WxDxH) mmWeight kgNoise level dBA±3Air flow rate H/M/L CMMPlasma air purifying filterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(ID) mm

Model Unit ARNU07GCEU2 ARNU18GCFU2ARNU09GCEU2 ARNU12GCEU2 ARNU24GCFU2ARNU15GCEU22.2

7,5002.5

8,5003030

2735 / 33 / 31

8.5 / 7.5 / 6.5-

Ø6.35(1/4)Ø12.7(1/2)

12

5.619,100

6.321,500

8080

3440 / 37 / 3416 / 14 / 12

-Ø6.35(1/4)Ø12.7(1/2)

12

2.89,600

3.210,900

3030

2736 / 34 / 32

9.5 / 8.5 / 7.5-

Ø6.35(1/4)Ø12.7(1/2)

12

3.612,300

4.013,600

3030

2737 / 35 / 33

10.5 / 9.5 / 8.5-

Ø6.35(1/4)Ø12.7(1/2)

12

7.124,200

8.027,300

8080

3443 / 40 / 3718 / 16 / 14

-Ø9.52(3/8)

Ø15.88(5/8)12

4.515,400

5.017,100

30 30

2738 / 37 / 35

11.5 / 10 / 9.5-

Ø6.35(1/4)Ø12.7(1/2)

12

2.27,500

2.58,500

3030

2035 / 33 / 31

8.5 / 7.5 / 6.5-

Ø6.35(1/4)Ø12.7(1/2)

12

5.619,100

6.321,500

8080

2740 / 37 / 3416 / 14 / 12

-Ø6.35(1/4)Ø12.7(1/2)

12

2.89,600

3.210,900

3030

2036 / 34 / 32

9.5 / 8.5 / 7.5-

Ø6.35(1/4)Ø12.7(1/2)

12

3.612,300

4.013,600

3030

2037 / 35 / 33

10.5 / 9.5 / 8.5-

Ø6.35(1/4)Ø12.7(1/2)

12

7.124,200

8.027,300

8080

2743 / 40 / 3718 / 16 / 14

-Ø9.52(3/8)

Ø15.88(5/8)12

4.515,400

5.017,100

30 30

2038 / 37 / 35

11.5 / 10 / 9.5-

Ø6.35(1/4)Ø12.7(1/2)

12

1, 220~240, 501345x203x6351067x203x635

1, 220~240, 501256x190x639978x190x639

Wired remote controller Wireless remote controller

Deluxe type

PQRCUDS0*Standard type

PQRCUSA1 Simple type

PQRCUCS0C Simple type for hotel

PQRCFCS0C PQWRHDF0

Wired remote controller Wireless remote controller

Deluxe type

PQRCUDS0*Standard type

PQRCUSA1 Simple type

PQRCUCS0C Simple type for hotel

PQRCFCS0C PQWRHDF0

* Check up the note, refer to on the 49 page. * Check up the note, refer to on the 49 page.

Page 33: Multi v Hz R410A)

LG A

ir Conditioners System

64

_6

5

Heat Recovery Ventilator

Features

Installation & Maintenance

Line-up

Specifications

62636466

eco V

With today’s concern for a healthy indoor environment, eco V is an integral component of HVAC system. eco V Using in the HVAC system allows contaminants to be removed quickly and effectively from the air-conditioned space.

Heat Recovery Ventilator

LG’s heat recovery ventilation system,

eco V, modulates the temperature and

humidity of incoming fresh air to match

indoor conditions. A balance is achieved

between indoor and outdoor ambient,

enabling the cooling or heating load

placed on the air conditioning system to

be reduced significantly.

(Heat Recovery ventilator)

Page 34: Multi v Hz R410A)

(Heat Recovery ventilator)

LG A

ir Conditioners System

66

_6

7

Easy Cleaning and Changing FilterDoor attached side panel and slide removable Enthalpy heat exchanger filter can be changed without additional maintenance.

• Eco V unit

Top

Low

Low

Top

Reverse installationof 1 unit (Left unit)

Normal installationof 2 units

Flexibility of InstallationIt’s possible to install the opposite direction of upper and lower part. It needs the only one inspection hole.

• Inspection hole

Air Filter Air Filter

Strong Filter FunctionAir filterThe air filter has collection efficiency above 80%, which means it can filter particles up to 0.3 m including tobacco of smoke and even floating particles from yellow sand.

HEPA + Deodorization filter (accessory)The indoor air can be always kept fresh through these filters.

Yellow Sand filter (accessory)This filter can make more comfortable and fresh environment through removing harmful to health 5~20µm sandy dust over 99%.

• Air Filter

• HEPA+Deodorization Filter (accessory)

• Yellow Sand Filter (accessory)Dust collection efficiency (%) Pressure loss (Pa)

• Remove side panel

Installation & Maintenance • Flexibility Installation • Easy Cleaning and Changeable Filter

Features • High Efficiency Heat Exchanger • Bypass Ventilation • Strong Filter Function

High Efficiency Heat ExchangerEfficiency and comfort is ensured by the high-efficiency energy recovery central core which recovers energy from the indoor air and transfers it to the fresh incoming air without mixing airstream.

Exhaust air

Outdoor air (Option) Deodorization filter

Supply air

Indoor airHigh performance filter{

Bypass VentilationIt switches automatically the ventilation mode (Enthalpy Heat Exchange Mode / Bypass Mode) according to the indoor/outdoor temperature.

• Remove heat exchanger• Remove free filter

Damper Damper

• Enthalpy Heat Exchange Mode

• Bypass Mode

[Summer / Winter] [A change of season]

Page 35: Multi v Hz R410A)

LG A

ir Conditioners System

68

_6

9 (H

eat Recovery ventilator)

The LG heat recovery ventilation system, eco V

is the solution for improving your indoor air quality.

• High Efficiency Heat Exchanger

• Bypass Ventilation

• Strong Filter Function

• Flexibility of Installation

• Easy Cleaning and changeable Filter

Power Supply [Ø,V,Hz] _1Ø, 220-240V, 50Hz

Dimension [WxHxD]_204x509x509mm[8.03x23.23x23.23inch]

Weight_ 24kg[52.91lb]

Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50Hz

Dimension (WxHxD) _ 590x204x590mm (23.23x8.03x23.23 inch)

Weight _ 24kg (52.91 lb)]

Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50Hz

Dimension (WxHxD) _ 596x320x640mm (23.46x12.60x25.20 inch)

Weight _ 27kg (59.51 lb)

Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50Hz

Dimension (WxHxD) _ 988x273x1014mm (38.9x10.75x39.92 inch)

Weight _ 45kg (99.2 lb)

Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50HzDimension (WxHxD) _ 988x273x1014mm (38.9x10.75x39.92 inch) Weight _ 52kg (114.7 lb)

Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50HzDimension (WxHxD) _ 1062x365x1140mm (41.9x14.4x44.9 inch) Weight _ 67kg (147.7lb)

Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50HzDimension (WxHxD) _ 1062x365x1140mm (41.9x14.4x44.9 inch) Weight _ 67kg (147.7lb)

Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50Hz Dimension (WxHxD) _ 1313x737x1140mm (51.7x28.8x44.9 inch) Weight _ 146kg (321.9 lb)

Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50HzDimension (WxHxD) _ 1313x737x1140mm (51.7x28.8x44.9 inch)Weight _ 146kg (321.9 lb)

LZ-H0106BA0 LZ-H0156BA0

LZ-H0356BA0 LZ-H0256BA0

LZ-H0506BA0

LZ-H0806BA0

LZ-H1006BA0

LZ-H1506BA0

LZ-H2006BA0

Page 36: Multi v Hz R410A)

LG A

ir Conditioners System

70_

71 (H

eat Recovery ventilator)

eco V ensures the fresh enviroment in your life!Heat Recovery Ventilator

* Specifications

LZ-H0106BA0

100(28)

1, 220-240, 50

SUPER-HIGH/HIGH/LOW

0.32/0.3/0.28

68/60/50

100/100/90(59/59/53)

40/35/30(0.16/0.14/0.12)

78/78/80

68/68/70

58/58/60

28/26/20

- / - / -

- / - / -

- / - / -

- / - / -

- / - / -

- / - / -

- / - / -

- / - / -

- / - / -

Crossflow

24(52.91)

590x204x590(23.23x8.03x23.23)

4

Ø100(Ø3.94)

1

Direct-Drive

1

Direct-Drive

2

Cleanable

580x10x113(22.83x0.39x4.45)

LZ-H0156BA0

150(42)

1, 220-240, 50

SUPER-HIGH/HIGH/LOW

0.36/0.36/0.35

83/80/78

150/150/100(42/42/28)

70/55/45(0.28/0.22/0.18)

75/75/79

62/62/69

55/55/59

32/30/22

- / - / -

- / - / -

- / - / -

- / - / -

- / - / -

- / - / -

- / - / -

- / - / -

- / - / -

Crossflow

24(52.91)

590x204x590(23.23x8.03x23.23)

4

Ø100(Ø3.94)

1

Direct-Drive

1

Direct-Drive

2

Cleanable

580x10x113(22.83x0.39x4.45)

LZ-H0256BA0

250(69)

1, 220-240, 50

SUPER-HIGH/HIGH/LOW

0.55/0.5/0.34

130/115/80

250/250/180(69/69/50)

65/50/40(0.26/0.2/0.16)

80/80/85

70/70/78

64/64/68

32/28/21

- / - / -

- / - / -

- / - / -

- / - / -

- / - / -

- / - / -

- / - / -

- / - / -

- / - / -

Crossflow

27(59.51)

596x320x640(23.46x12.60x25.20)

4

Ø150(Ø5.91)

1

Direct-Drive

1

Direct-Drive

2

Cleanable

580x10x175(23.23x0.39x6.89)

LZ-H0356BA0

350(97)

1, 220-240, 50

SUPER-HIGH/HIGH/LOW

1.40/1.33/0.9

205/195/170

350/350/210(97/97/58)

170/88/40(0.68/0.35/0.16)

83/83/87

80/80/85

78/78/83

33/28/23

SUPER-HIGH/HIGH/LOW

1.40/1.33/0.9

205/195/170

350/350/210(97/97/58)

170/88/40(0.68/0.35/0.16)

- / - / -

- / - / -

- / - / -

33/28/23

Crossflow

45(99.20)

988x273x1014(38.9x10.75x39.92)

4

Ø200(Ø7.87)

1

Direct-Drive

1

Direct-Drive

2

Cleanable

855x10x166(33.66x0.39x6.54)

Unit

CMH(L/S)

Ø,V,Hz

-

Amps

W

CMH(L/S)

Pa(in.wg)

%

%

%

dBA

-

Amps

W

CMH(L/S)

Pa(in.wg)

%

%

%

dBA

-

kg(lb)

mm(inch)

EA

mm(inch)

EA

-

EA

-

EA

-

mm(inch)

Step

Current

Power Input

Air Flow

External Static Pressure

Temperature Exchange Efficiency

Enthalpy Exchange Efficiency

Noise Level(Sound Level, 1.5m)

Step

Current

Power Input

Air Flow

External Static Pressure

Temperature Exchange Efficiency

Enthalpy Exchange Efficiency

Noise Level(Sound Level, 1.5m)

Item

Nominal Capacity

Power Supply

Heat Exchanger

Weight

Dimension

Duct work

Supply Air Fan

Exhaust Air Fan

Filters

LZ-H0506BA0

500(139)

1, 220~240, 50

SUPER-HIGH/HIGH/LOW

1.51/1.39/1.06

260/225/200

500/500/320(139/139/89)

150/60/28(0.60/0.24/0.11)

75/75/79

75/75/80

70/70/75

34/32/25

SUPER-HIGH/HIGH/LOW

1.51/1.39/1.06

260/225/200

500/500/320(139/139/89)

150/60/28(0.60/0.24/0.11)

- / - / -

- / - / -

- / - / -

34/32/25

Crossflow

52(114.7)

988x273x1014(38.9x10.75x39.92)

4

Ø200(Ø7.87)

1

Direct-Drive

1

Direct-Drive

2

Cleanable

855x10x166(33.66x0.39x6.54)

Notes:1. eco mode - Enthalpy Heat Recovery Ventilation mode2. Noise level : - The operating conditions are assumed to be standard. - Sound measured at 1.5m below the center the body. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed.

eco

V M

ode

Byp

ass

Mod

e

SH/H/L

SH/H/L

SH/H/L

SH/H/L

SH/H/L

Heating(SH/H/L)

Cooling(SH/H/L)

SH/H/L

SH/H/L

SH/H/L

SH/H/L

SH/H/L

SH/H/L

Heating(SH/H/L)

Cooling(SH/H/L)

SH/H/L

Type

WxHxD

Qty

Size(Ø)

Qty

Type

Qty

Type

Qty

Type

Size(WxHxD)

* Specifications

Unit

CMH(L/S)

Ø,V,Hz

-

Amps

W

CMH(L/S)

Pa(in.wg)

%

%

%

dBA

-

Amps

W

CMH(L/S)

Pa(in.wg)

%

%

%

dBA

-

kg(lb)

mm(inch)

EA

mm(inch)

EA

-

EA

-

EA

-

mm(inch)

Item

Nominal Capacity

Power Supply

Heat Exchanger

Weight

Dimension

Duct work

Supply Air Fan

Exhaust Air Fan

Filters

LZ-H1006BA0

1000(278)

1, 220~240, 50

SUPER-HIGH/HIGH/LOW

3.0/2.9/2.6

560/540/470

1000/1000/800(278/278/222)

160/90/50(0.80/0.44/0.24)

75/75/78

66/66/71

61/61/66

37/35/31

SUPER-HIGH/HIGH/LOW

2.8/2.7/2.4

560/540/470

1000/1000/800(278/278/222)

160/90/50(0.80/0.44/0.24)

- / - / -

- / - / -

- / - / -

37/35/31

Crossflow

67(147.7)

1062x365x1140 (41.9x14.4x44.9)

4

Ø250(Ø9.54)

1

Direct-Drive

1

Direct-Drive

2

Cleanable

1056x10x212.5(41.57x0.39x8.37)

LZ-H1506BA0

1500(417)

1, 220~240, 50

SUPER-HIGH/HIGH/LOW

5.6/5.4/5.2

950/925/795

1500/1500/1200(417/417/333)

200/110/60(0.80/0.44/0.24)

79/79/82

70/70/75

65/65/70

39/37/33

SUPER-HIGH/HIGH/LOW

5.6/5.4/5.2

950/925/795

1500/1500/1200(417/417/333)

200/110/60(0.80/0.44/0.24)

- / - / -

- / - / -

- / - / -

37/35/31

Crossflow

146(321.9)

1313x737x1140(51.7x28.8x44.9)

4+2

Ø250(Ø9.54)+Ø350(Ø13.77)

2

Direct-Drive

2

Direct-Drive

4

Cleanable

1056x10x212.5(41.57x0.39x8.37)

LZ-H2006BA0

2000(556)

1, 220~240, 50

SUPER-HIGH/HIGH/LOW

6.0/5.8/5.2

1020/970/860

2000/2000/1600(556/556/444)

160/90/50(0.80/0.44/0.24)

75/75/78

66/66/71

61/61/66

39/37/33

SUPER-HIGH/HIGH/LOW

5.6/5.4/4.8

1020/970/860

2000/2000/1600(556/556/444)

160/90/50(0.80/0.44/0.24)

- / - / -

- / - / -

- / - / -

37/35/31

Crossflow

146(321.9)

1313x737x1140(51.7x28.8x44.9)

4+2

Ø250(Ø9.54)+Ø350(Ø13.77)

2

Direct-Drive

2

Direct-Drive

4

Cleanable

1056x10x212.5(41.57x0.39x8.37)

LZ-H0806BA0

800(222)

1, 220~240, 50

SUPER-HIGH/HIGH/LOW

2.8/2.7/2.6

405/360/320

800/800/660(222/222/183)

200/110/60(0.80/0.44/0.24)

79/79/82

70/70/75

65/65/70

36/34/30

SUPER-HIGH/HIGH/LOW

2.8/2.7/2.6

405/360/320

800/800/660(222/222/183)

200/110/60(0.80/0.44/0.24)

- / - / -

- / - / -

- / - / -

36/34/30

Crossflow

67(147.7)

1062x365x1140 (41.9x14.4x44.9)

4

Ø250(Ø9.54)

1

Direct-Drive

1

Direct-Drive

2

Cleanable

1056x10x212.5(41.57x0.39x8.37)

Notes:1. eco mode - Enthalpy Heat Recovery Ventilation mode2. Noise level : - The operating conditions are assumed to be standard. - Sound measured at 1.5m below the center the body. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed.

eco

V M

ode

Byp

ass

Mod

e

Step

Current

Power Input

Air Flow

External Static Pressure

Temperature Exchange Efficiency

Enthalpy Exchange Efficiency

Noise Level(Sound Level, 1.5m)

Step

Current

Power Input

Air Flow

External Static Pressure

Temperature Exchange Efficiency

Enthalpy Exchange Efficiency

Noise Level(Sound Level, 1.5m)

SH/H/L

SH/H/L

SH/H/L

SH/H/L

SH/H/L

Heating(SH/H/L)

Cooling(SH/H/L)

SH/H/L

SH/H/L

SH/H/L

SH/H/L

SH/H/L

SH/H/L

Heating(SH/H/L)

Cooling(SH/H/L)

SH/H/L

Type

WxHxD

Qty

Size(Ø)

Qty

Type

Qty

Type

Qty

Type

Size(WxHxD)

Page 37: Multi v Hz R410A)

LG A

ir Conditioners System

72_73

V-net Line up

Remote Controller

Central Controller

Wireless RemoteController

Simple Central Controller

Wired RemoteController

AC Smart &128 Unit Expansion Kit

Accessory

Simple

Standard

Deluxe

PQWRHDF0

PQRCUCSOCPQRCFCSOC

PQRCUSA1

PQRCUDS0 (White)PQRCUDS0B (Blue)PQRCUDS0S (Silver)

PQCSB101S0PQCSB101S0+PQCSC101S0PQCSB101S0+PQCSD130A0

PQCSW320A0E

& Accessory(LG Network Solution)

& Accessory

Remote Controller

Central Controller

Accessory

74

76

84

V- n e t & A c c e s s o r yPDI, Remote temperature sensor, Dry contact, Cool/Heat selector, DO KitVentilation Kit (4Way Cassette), AHU Control kit & EEV kit, Refrigerant Charging KitAir guide, Suction grille and canvas, Heat recovery unit, Header, Y branch

(Function controller) (Scheduler)

ACP&AC ManagerPQCPA11A0E(Without IO)PQCPB11A0E(With IO)PQCSS520A0E(AC Manager)

BNU

PQNFB17B0(BACnet)

PQNFB16A1( )

PQCSE440U0

Page 38: Multi v Hz R410A)

LG A

ir Conditioners System

74_

75

* Wireless Remote Controller

Simple

Operating modeMode changeRoom tempPlasmaAuto swingChild lock

On_Off / Fan speed / Mode / Temp.Cooling / Heating / Fan

√√√√

PQRCUCSOC

Simple for Hotel

PQRCFCSOC

PQWRHDF0

Features PQRCUCSOC

Operating modeMode changeRoom tempPlasmaAuto swingChild lock

On_Off / Fan speed / Temp.Impossible

√√√√

Features PQRCFCSOC

Features PQWRHDF0

On_Off / Fan speed / Mode / Temp.√√√√

MULTI V SYNC II

Operating modeRoom temperature checkingChaos swing / Jet coolOn_Off timerSleep mode autoMain / Sub setting of indoor units ΔT setting (for Auto Changeover)

* Wired Remote Controller for Air-conditioner

Standard (WIDE)

PQRCUSA1

Features PQRCUSA1

& Accessory

Remote ControllerOur air conditioning system can be controlled by various types of remote controllers providing general control to unique function.

Remote Controller•Wired Remote Controller

•Simple Wired Remote Controller

•Wireless Remote Controller

* Wired Remote Controller for

Standard

Features PZRCUSB0

On / Off LEDVentilation mode settingRapid ventilationPower saving ventilationReservationElectric failure compensationChild lock

√√√√

Weekly / Simple Max. 2 hours

* Simple Wired Remote Controller

Deluxe

PQRCUDS0 (White) PQRCUDS0B (Blue)PQRCUDS0S (Silver)

Features PQRCUDS0, PQRCUDS0B, PQRCUDS0S

On_Off / Fan speed / Mode / Temp.√√√√√

Weekly / Simple√√

Operating modeTouch screen / LCD bak_lightRoom temp.Fan / Plasma / Swirl / HeaterVane control / Auto swing E.S.P functionReservationTimer functionChild lock

Operating modeOn / Off LEDRoom temp.Fan / Plasma / Swirl / HeaterVane control / Auto swing / Fan autoE.S.P functionReservationTimer functionChild lockElectric failure compensationWireless remocon receiverMaster setting of indoor unitsΔT setting (For Auto Changeover)2 Controllers to 1 indoor units

On_Off / Fan speed / Mode / Temp.√√√√√

Weekly / Simple√√

Max. 2 hours√

MULTI V SYNC II

Optional function Plasma / Heater / HumidifierOperating air volume

: Applicable for only MULTI V II SERIES

PZRCUSB0

: Applicable for only MULTI V II SERIES

Page 39: Multi v Hz R410A)

LG A

ir Conditioners System

76_

77

AC Smart & 128 Unit Expansion KitFor the mid sized buildings up to 64 or 128 indoor units can be controlled and monitored by touch screen central controller. It’s possible to control and monitor the air conditioning system through web access, anywhere with computer.

PQCSW320A0E

• Combination

RS4851.25mm2 X 2C

(shield)

AC220V

PMNFP14A0 (Max. 16 Indoors)PMNFP14A1 (Max. 48 Indoors)

PMNFP14A0

PHNFP14A0 (Ceiling & Floor, Duct)PSNFP14A0 (CST, RAC)

PHNFP14A0

DC Comm, LineAC Smart

PQCSW320A0E

PQCSB101S0PQCSC101S0

Function Controller & SchedulerIt is possible to control, monitor and schedule the operation of indoor units by using these controllerin company with a simple central controller

PQCSB101S0

Simple Central Controller• A central controller for managing small sites• Control up to 16 indoor units

Max. no of indoor units

Individual control

Lock function

Mode change

Malfunction indicator

Dimension(mm)

Power(V)

16 indoor units

On_Off Control

Total / Individual

Cooling / Heating

LED lamp

120 x 120 x 20

DC 10V

Features PQCSB101S0

& Accessory

* 1 Function controller combined with max. 8 simple central contollers.

Features PQCSB101S0+PQCSC101S0

16 indoor units

On_Off / Fan speed / Mode / Temp.

Total / Individual

Cooling / Heating / Fan

Error display on LCD

Weekly

(120x120x20)+(120x133x20)

DC 10V

16 indoor units

On_Off / Fan speed / Mode / Temp.

Total / Individual

Cooling / Heating / Fan

Error display on LCD

-

(120x120x20)+(70x120x14)

DC 10V

Max. no of indoor units

Individual control

Lock function

Mode change

Malfunction indicator

Schedule

Dimension(mm)

Power(V)

PQCSB101S0+PQCSD130A0

PQCSB101S0PQCSD130A0

*128 Indoor unit Expansion Kit: PQCSE440U0*DO Kit : PQNFP00T0

PI485

PQCSE440U0

Single constant

Eco-V

Single A, MULTI

MULTI V PLUS IIMULTI V SYNC IIMULTI V SPACE IIMULTI V MINI

MULTI V PLUSMULTI V SYNCMULTI V SPACE

Page 40: Multi v Hz R410A)

LG A

ir Conditioners System

78_

79 &

Accessory

ACP (Advanced Control Platform)

PQCPA11A0E (Without IO)PQCPB11A0E (With IO)

• Through embedded web control function in ACP one can control and monitor various functions of air-conditioner such as temperature setting, schedule, peak power control, etc.

• Features

Application

Multi Area ManagementThe product specially designed for multi area management.-Central control & monitor Max. 4,096 indoor units & Max.16 ACP

Max. 4,096 Indoor

ACP AC ManagerKorean reference site.

ACP&AC Manager• AC Manager is suitable for large site because AC Manager is the S/W that can control Max. 16 ACP (Max.4,096 indoor units).

PQCPA11A0E (Without IO)PQCPB11A0E (With IO)

PQCSS520A0E (AC Manager)

PQCPA(B)11A0E

Max.no. of indoor units

Control / Monitoring

Schedule management

Lock function

Temperature range restriction

Temperature limit function

Auto Changeover function

History function

Peak control

PDI monitoring

Interlocking function

Printing function

256 indoor units

Temperature

-

-

-

Monitoring

Need of PDI

-

-

4,096 indoor units(16 ACP)

Mode/Temp/Fan speed/Schedule

Monitoring & Error history

Need of PDI

-

System setting, History, PDI

4,096 indoor units(16 ACP)

Mode/Temp/Fan speed/Schedule

Monitoring & Error history

Need of PDI

Fire sensor, Door sensor, Motion sensor...

System setting, History, PDI

PQCPA11A0E+PQCSS520A0E PQCPB11A0E+PQCSS520A0E

ACP ACP (without IO) + AC Manager ACP (with IO) + AC Manager

Application

• Combination

AC ManagerPQCSS520A0E

Internet

AC220V

PHNFP14A0 (Ceiling & Floor, Duct)PSNFP14A0 (CST, RAC)

PMNFP14A0

PMNFP14A0 (Max. 16 Indoors)PMNFP14A1 (Max. 48 Indoors)

Single constant

Eco-V

Single A, MULTI

DC Comm, Line

MULTI V PLUS IIMULTI V SYNC IIMULTI V SPACE IIMULTI V MINI

MULTI V PLUSMULTI V SYNCMULTI V SPACE

HUB

RS4851.25mm2 X 2C

(shield)

LANPI485

PHNFP14A0

PI485

Page 41: Multi v Hz R410A)

LG A

ir Conditioners System

80

_8

1 &

Accessory

• Combination

DO Kit• Do Kit is connected between ACP (AC Smart) and external devices. So ACP(AC Smart) can start and stop external devices such as light, pump, motor, etc.

PQNFP00T0

• Features - Accumulated total power consumption indicated - Accumulated / Current power consumption of each indoor units indicated - Accumulated power consumption by month indicated - Max connectable no. of indoor units : 48 indoor units - 1 PDI per 1 outdoor unit - Power failure-proof function : Data back up on EEPROM even if power turns off - Connectable to PC based central controller

- Simple connection with the remote metering system (RS485 approach)

• Combination

PQNUD1S00

Pulse output (1,2, 4,6,8,10W/pulse)AC 200V~240V 50/60Hz

Digital WHM(Local purchase)

AC220V

RS485

PDI (Power Distribution Indicator)

• This device is an indicator for power consumption of the multi type air-conditioner used for common power line.

PQNUD1S00

or

* In the case of MULTI V II SERIES, don’t need PI 485

PI485

Power of LoadBUS _ A

BUS _ B

L N

Web Access - Remote Management - Error Report via E-mail

Operation Report-Operating Time, Percentage, History

Emergency Interlock-Forced Off

128 Indoor unitsExpansion Kit

Multiple Local Controllers-Master / Slave

Multi Language-English, Italian, Spanish, French, German, Dutch, Russian

Easy Control-Function Lock-Lock Schedule

Comfort Control-Automatic H/C Changeover-Temperature Limit-Temperature Range Restriction-Time Limit Control

AC Smart• 7" Touch Screen / GUI

• Direct Connect to LGAP

DO Kit

• Remote Controller Restriction• Automatic Setting• A/C and Vent.

Easy Software Upgrade by USB

DI RS485

USB

Screen Saver

EmergencyLGAP

Light Pump Motor etc

Cooling

Heating

ACP or AC Smart

Page 42: Multi v Hz R410A)

LG A

ir Conditioners System

82_

83

• Features - Through embedded web control function in BACnet one can access the airconditioner and external devices through internet. - It can control 256 indoor units. ( A/C or Ventilator ) - External devices such as fire alarm, motion detector can be connected to gateway and their function can be interlinked with airconditioner operation.

• Combination

& Accessory

PQNFB17B0

BNU-BAC Gateway (Building Network Unit- BACnet)

Easy interface between BMS and LG air conditioner- Independence of BMS under the standard BMS : Operation system based on BACnet Service.

Controlling Monitoring items

On/Off command

Operation mode setting

Fan speed setting

Lock setting

Air flow setting

Set temp. setting

User mode setting (for only ventilator)

On/Off status report

Operation mode status report

Fan speed status report

Lock status report

Air flow status report

Current space temp. status report

Error status report

User mode status report(for only ventilator)

• Combination

• Features - Connection to using LONTALK protocol and LG Air-conditioner protocol

- Process ability • 64 units( including indoors and ventilators) • Valid address for each unit : 0x00 ~ 0x3F

- Self installation verification function using internet (Web server included) • Setting gateway • Diagnosis of communication status on LG Air-conditioner network

- Connection to remote total management system (LG system)

PQNFB16A1

BNU-LW Gateway (Building Network Unit- )

Easy interface between BMS and LG air conditioner- Independence of BMS under the standard BMS : Operation system based on LNS ( network service) - No network installation needed - Very widely applicable protocol( )

NetworkBMS system

PHNFP14A0

Lighting control

Other LON devicesIndoor unit : Max. 64 units (Air-conditioner & ventilation)Indoor address : 00 ~ 3F

Remote checking Utility control

LGAP applied Air-conditioner

Outdoor unit Indoor unit

BNU-LWPQNFB16A1

LON comm. line

Simple centralcontroller

or

AC Smart

PI485

PI485

Controlling Monitoring items

On/Off command

Operation mode setting

Fan speed setting

Lock setting

Air flow setting

Set temp. setting

User mode setting (for only ventilator)

On/Off status report

Operation mode status report

Fan speed status report

Lock status report

Air flow status report

Set temp. status report

Current space temp. status report

Error status report

User mode status report(for only ventilator)

PI485PMNFP14A0

PMNFP14A0 (Max. 16 Indoors)PMNFP14A1 (Max. 48 Indoors)

BACnetNetwork

BMS system

PHNFP14A0

LGAP applied Air-conditioner

Outdoor unit

Lighting control

Other BACnet devicesIndoor unit : Max. 256 units (Air-conditioner & ventilation)Indoor address : 00 ~ FF

Remote checking Utility control

BNU-BACPQNFB17B0

BACnet comm. line

Indoor unitSimple centralcontroller

or

AC Smart

PI485

PI485

PI485

PMNFP14A0

PMNFP14A0 (Max. 16 Indoors)PMNFP14A1 (Max. 48 Indoors)

Eco-V

Single A, MULTI

MULTI V PLUS IIMULTI V SYNC IIMULTI V SPACE IIMULTI V MINI

MULTI V PLUSMULTI V SYNCMULTI V SPACE

Eco-V

Single A, MULTI

MULTI V PLUS IIMULTI V SYNC IIMULTI V SPACE IIMULTI V MINI

MULTI V PLUSMULTI V SYNCMULTI V SPACE

RS4851.25mm2 X 2C

(shield)

RS4851.25mm2 X 2C

(shield)

Page 43: Multi v Hz R410A)

Mode Change

Heating

Fan Mode

Cooling

LG A

ir Conditioners System

84

_8

5

• Combination

& Accessory

• Features - Indoor unit control without central controller - Select operation mode : Cooling, Heating, Fan mode - Mode lock for cooling & heating mixing error-proof during the change of season.

Cool/Heat SelectorThis switch enables selection of heating, cooling or fan mode. So it can prevent that cooling & heating mixing error occurs during the change of season.

PRDSBM

* PRDSBM is applicable for only MULTI V II Series.

Fresh air can be supplied from outside through this ventilation kit.

PTVK410 PTVK420 PTVK430

Ventilation Kit (4Way Cassette)

• Accessory• Installation Bracket• Bolt• Screw

• Dimension

• Models applied to

• Wiring diagram 1. Wire to the control box in the indoor unit by removing the existing thermistor and connect the extension cable its place. 2. Cut the extension cable to the appropriate length and connect the screw terminal of the remote sensor. 3. In the case of wired remote controller installed, set the temperature sensing slide s/w at MAIN mode.

Connector

Remote temperature sensor

Extension cable

Screw terminal connection

Indoor unit

Remote Temperature SensorIt can help to detect the exact room temperature at the optimal position.

• Model applied to Cassette, Duct type.• Part supplied - Remote temperature sensor - Cable (15m) - ManualPQRSTA0

PQDSB(A) / PQDSB1 / PQDSBC

Dry Contact module• It is connected between indoor units and external device, so it can be used for various purpose.

* PQDSBC is applicable for only MULTI V II Series.

• Features

Contact point

PQDSA(B) PQDSB1 PQDSBC

Voltage / Non voltage input

On_Off control

Lock / Unlock

Fan speed setting

Thermo off

Energy saving

Expected temperature setting

Error Monitoring

Operation monitoring

Power input

1 contact point

AC 220V from outside power source

1 contact point

AC 24V from outside power source

2 contact points

DC 5V&12V from indoor unit PCB

• Ceiling Cassette - 4Way (24k ~ 48k Btu/h)

Page 44: Multi v Hz R410A)

LG A

ir Conditioners System

86

_8

7 &

Accessory

Refrigerant Charging Kit

PRAC1

• Procedure 1. Arrange manifold, refrigerant charging kit, refrigerant vessel and scale 2. Connect manifold to the gas pipe service valve of outdoor uint as shown in the figure. 3. Connect manifold refrigerant charging kit. Use designated refrigerant charging kit. If designated refrigerant charging kit isn’t used, the system may get damaged. 4. Connect refrigerant charging kit and refrigerant vessel. 5. Purge hose and manifold. 6. After “568” is displayed, open the valve and charge the refrigerant

• Error contents about auto refrigerant charging function

1. “329”: Temperature range error (In case that indoor unit or outdoor unit is out of range) 2. “339”: Low pressure descent error (In case the system runs at low pressure limit for over 10 minutes) 3. “349”: Rapid refrigerant inflow (In case the liquid refrigerant flows in because of not using designated refrigerant charging kit) 4. “359”: Instability error (In case the high/low pressure target doesn’t get satisfied for some time after the starting operation)

• Application • Dimension

133

69

202Manifold

Refrigerant

Refrigerant Charging Kit

AHU Control Kit & EEV KitFresh air can be supplied from outside connecting AHU to Multi V Plus II.

PRCKA0 PRLK048A0

• Specifications

Control KitEEV Kit

NETPOWERModel Name

Gross W H D

Weight(kg) Dimension(mm)

PRCKA0PRLK048A0

2.233.1

3.63.6

280404.2

13583

280217

220~240V / 50HZ / 1Pha

When selecting evaporator, Change ‘Option PCB’ in EEV kit according to below table(Basic ‘Option PCB is for 36k Btu/h )

• Selection of evaporator

Option PCB P/No Capacity (Btu/h)

Allowed heat exchanger Volume (dm3/hr)

Allowed heat exchanger capacity (kW)

EBR52358907

EBR52358908

EBR52358909

EBR52358910

EBR52358911

EBR52358912

28k

36k

42k

48k

76k

96k

1.22~1.53

1.53~1.91

1.91~2.14

2.14~2.67

3.06~3.82

3.82~4.78

7~9

9~11

11~13

13~16

20~24

25~31

* Saturated Suction Temperature (SST) = 6ºC, SH (Superheat)=5k, Air Temperature = 27ºC DB / 19ºC WB

(Main PCB)

Detail

Capacity setting'Option PCB'

• Wiring diagram

Single

Pipe

Themistor Return Air

Supply Air

(PRAC1)

Page 45: Multi v Hz R410A)

LG A

ir Conditioners System

88

_8

9

Indoor unit

Outdoor unit

2

26

26

19

801x218x617

9.52(3/8)

19.05(3/4)

19.05(3/4)

Max. connectable number of indoor units

Max. connectable capacity of indoor units (Per port/unit) kW

Nominal Input cooling W

heating W

Net weight kg

Dimensions (WxHxD) mm

Piping Indoor liquid mm(inch)

connections unit gas mm(inch)

Outdoor liquid mm(inch)

unit low pressure mm(inch)

high Pressure mm(inch)

Power supply Ø/V/Hz

3

40

40

20

801x218x617

12.7(1/2)

28.58(1 1/8)

22.2(7/8)

4

40

40

21

801x218x617

12.7(1/2)

28.58(1 1/8)

22.2(7/8)

9.52(3/8)15.88(5/8)

1/220 ~ 240/50

PRHR020 PRHR030 PRHR040

14.1 / 47

• Specifications

PRHR020(2 Pipe-connection)

PRHR030(3 Pipe-connection)

• Combination

& Accessory

Heat recovery unit (Applied to MULTI V SYNC II R410A)

• Max. 4 indoor units can be connected by module design.

• Due to the automatic search algorithm for piping detection, easy installation and effectiveness is improved.

• Subcooling cycle in HR unit makes the system efficiency maximum.

PRHR040(4 Pipe-connection)

• Application • Dimension

• Features - High external static pressure facilitates unit use with flexible ducts of varying lengths. - When using suction panel, unit requires only 270mm of ceiling space. - Blends unobtrusively with any interior decoration.

PBSGB30

PBSGB40

A B C

910

1188

359

359

56

56

PBSC30

PBSC40

A B C

821

1100

274

274

42~250

42~250

• Models applied to - Ceiling concealed duct _ Built-in type

Type

Capacity (Btu/h)

7kModel

Grille

Canvas

PBSGB30PBSGB40

PBSC30PBSC40

√√

9k 12k 15k 18k 24k

C

A

B A

B

C

PQAGA

Air Guide• Used to control the direction of air discharge by outdoor unit.

• Converts vertical discharge into horizontal discharge.

• Dimension

Suction Grille and Canvas• High flexibility for a wide variety of applications

PBSGB30 / PBSGB40PBSC30 / PBSC40

Page 46: Multi v Hz R410A)

If you need a highly efficient air condition-ing system in your building, MULTI V is the right choice for you.

Auto Clean

4-Way Air Deflection

Swirl Swing

Auto Restart

Sleep Mode Auto Operation

Weekly Program Wired remote controller only

Two Thermistor Control Wired remote controller only

Changable Panel

Second Remote Control

NEO Plasma Air Purifying System

Jet Cool

Child Lock Function Wired remote controller only

Healthy Dehumidification

Hot Start (Heat pump only)

Soft Dry Operation Mode

Low Standby Power

Group Control Wired remote controller only

Auto Changeover MULTI V SYNC model only

( )

( )

( )

( )

( )

LG A

ir Conditioners System

90

_9

1 &

Accessory

* MULTI V PLUS II, MULTI V MINI, MULTI V SPACE II

Model ModelGas Pipe Liquid Pipe Gas Pipe Liquid Pipe

(unit:mm) (unit:mm)

ARBLN07121

ARBLN14521

* MULTI V SYNC II

Model Low Pressure Gas Pipe Liquid Pipe

(unit:mm)

ARBLB01621

High Pressure Gas Pipe

ARBLB03321

ARBLB07121

ARBLB14521

Y Branch pipe for connection of indoor units

ARBLN01621

ARBLN03321

* MULTI V SYNC II (2 Outdoor units)

Model Low Pressure Gas Pipe

Liquid Pipe

(unit:mm)

ARCNB20

High Pressure Gas Pipe

* MULTI V SYNC II (3 Outdoor units)

Model Low Pressure Gas Pipe

Liquid Pipe

(unit:mm)

ARCNB20

High Pressure Gas Pipe

ARCNB30

Header for connection of indoor units

Y Branch pipe for connection of outdoor units

Model

4 branchARBL054

7 branchARBL057

4 branchARBL104

Model

7 branchARBL107

10 branchARBL1010

10 branchARBL2010

Gas Pipe Liquid Pipe Gas Pipe Liquid Pipe

(unit:mm) (unit:mm)

* MULTI V PLUS II (2 Outdoor units)

Model

ARCNN20

Model

ARCNN20

ARCNN30

Connection of Gas Pipe Connection of Liquid Pipe Connection of Gas Pipe Connection of Liquid Pipe

(unit:mm) (unit:mm)