7
Multi-Service IP DSLAM SURPASS hiX 5622/25/5630/5635 Release 2.8 Carrier Ethernet Comprehensive Solutions The Nokia Siemens Networks hiX 5622/5625/5630/5635 series of IP DSLAM is an innovative platform for access networks to provide broadband services on the last mile of the network i pl ,f f. t t t t f , I f . It f I t / + I f t All-in-One Multi-service IP DSLAM with all DSL flavours. Scalability guarantees best fit to your specific solution requirements Flexible & modular solution for Central Office (CO) or remote shelter for DSL deployment

Multi-ServiceIPDSLAM SURPASS … · 16k MAC addresses per DSLAM MAC address limitation per port MAC Anti spoofing (including Service Gateway) IP Anti spoofing 4096 VLANs VLAN assignment

Embed Size (px)

Citation preview

Page 1: Multi-ServiceIPDSLAM SURPASS … · 16k MAC addresses per DSLAM MAC address limitation per port MAC Anti spoofing (including Service Gateway) IP Anti spoofing 4096 VLANs VLAN assignment

Multi-Service IP DSLAMSURPASS hiX 5622/25/5630/5635

Release 2.8

Carrier Ethernet Comprehensive SolutionsThe Nokia Siemens Networks hiX 5622/5625/5630/5635 seriesof IP DSLAM is an innovative platform for access networks toprovide broadband services on the last mile of the network

i pl

, f

f.t

t

t t

f ,

I f.

It fI t

/ +

I

f

t

All-in-OneMulti-service IP DSLAMwith all DSL

flavours.

Scalability guarantees best

fit to your specific solution

requirements

Flexible & modular solution

for Central Office (CO) or

remote shelter for DSL

deployment

Page 2: Multi-ServiceIPDSLAM SURPASS … · 16k MAC addresses per DSLAM MAC address limitation per port MAC Anti spoofing (including Service Gateway) IP Anti spoofing 4096 VLANs VLAN assignment

General DSLAM Specifications

Mass rollout platform with universal slot

architecture for Interface Units (IU)

M series Chassis support 1 Gbps slot

capacity ( M400 / M600 / M1100 )

G series Chassis are prepared to

deliver up to 10 Gbps capacity per slot (

G200 / G400 / G600 / G1100) for any

future high bandwidth demanding

applications

Non Blocking Architecture (48 Gbps

switching)

GE Star from Central Card to each IU

slot

DC Powering (-48 V)

Redundant DC Power supply

Optional External AC Power supply

Optional External Redundant AC Power

supply

Fan Redundancy

Redundancy for Switch/Control Card

(no CXU redundancy for hiX5622)

Chassis design for 19” / ETSI rack

mounting (G200 and G400 not for 19”)

Front access including Control & Switch

Fabric

Central Office (CO) & Outdoor Cabinet

installation for hiX 5625 / hiX 5630, CO

for hiX 5635

Outdoor Cabinet & Indoor (building and

basement) installation for hiX5622

Separate shelf for splitters

Subtending interfaces option

Remote testing capability

IPv6 Hardware readiness

M400 shelf of hiX 5625

6 Slots (1CXU + 5 IU or 2 CXU (redundant)

+ 4 IU ) / horizontal layout

M600 shelf of hiX 5630

10 Slots (1 or 2 CXU (redundant)

+ 8 IU) / horizontal layout

M1100 shelf of hiX 5635

16 Slots (1 CXU + 15 IU or 2 CXU

(redundant) + 14 IU ) / vertical layout

G200 shelf of hiX 5622

3 Slots (1 CXU + 2 IU ) / horizontal layout

G400 shelf for hiX 5625

The G400 shelf is an alternative for customers who want to be prepared for future planned higher capacity interface units. Although the design is similar to the M400, the backplane is capable to offer up to 10 Gbps per slot. The G400 shelf fits in 23’’ or ETSI rack.

G600 shelf for hiX 5630

The G600 shelf is an alternative for customers who want to be prepared for future planned higher capacity interface units. Although the design is similar to the M600, the backplane is capable to offer up to 10 Gbps per slot. The G400 shelf fits in 23’’ or ETSI rack.

G1100 shelf for hiX 5635

The G1100 shelf is an alternative for

customers who want to be prepared for

future planned higher capacity interface

units. Although the design is similar to the

M1100, the backplane is capable to offer up

to 10 Gbps per slot.

1 or 2 x CXUs possible (second card

for 1+1 redundancy, standby

architecture)

CXU has 4 GE interfaces (different

SFP modules are available)

GE interface types available:

Electrical – SFP 100/1000 Base-T

auto-negotiation

Optical-SFP / (LX) single mode / (SX)

multi mode

Per port assignment of uplink

interface, e.g. network interface

(uplink) or cascading daisy uplink

protection with use of link aggregation

(LAG), LACP

Service Interface Units:

72 Port ADSL2+

(backward compatible

with ADSL and ADSL2)

48 Port SHDSL.bis (support SHDSL)

24 Port VDSL2

48 Port VDSL2

Number of slots dedicated for IU

2 slots in G200 chassis

5 slots in M400 chassis

8 slots in M600 and G600 chassis

15 slots in M1100 chassis

4 slots in G400 chassis

14 slots in G1100 chassis

Maximum number of subscribers per sub-

rack with 72 ADSL2+ or VoIP ports per

Interface Unit:

Up to 360 for hiX 5625 (M400)

Up to 576 for hiX 5630 (M600/G600)

Up to 1080 for hiX 5635 (M1100)

Up to 144 for hiX 5622 (G200)

Up to 288 for hiX 5625 (G400)

Up to 1008 for hiX 5635 (G1100)

Page 3: Multi-ServiceIPDSLAM SURPASS … · 16k MAC addresses per DSLAM MAC address limitation per port MAC Anti spoofing (including Service Gateway) IP Anti spoofing 4096 VLANs VLAN assignment

R2.8 SURPASS hiX 56xx software with multi- DSL

supports the mix of xDSL flavors including VDSL2

and GE line cards.

Key Features of Rel 2.8Mobile Backhauling support via SHDSL.bis (including

synchronization clock support)

Line probing for SHDSL.bis

EFM 4 pairs bonding and ATM M-Pair Mode with

SHDSL.bis

System Clock support (via External 2MHz Timing

Reference i.e. T3 / Synchronized Ethernet, G.8261)

Ability to copy 802.1p C-VLAN to S-VLAN

Extended Line Parameter Set for ANCP, DHCP Opt. 82

and PPPoE IA

IGMPv3 support with following function:

- IGMP Proxy;

- Explicit Host Tracking

- Source Specific Multicast

- IGMP proxy reporting

- IGMP Report suppression

- Support of Static Join

- Enhanced user statistic

QoS setting via mapping of TOS/DSCP bits to 802.1p,

QoS setting via usage of predefined 802.1p values

SP (strict priority for Downstream) , WFQ (WRR-like)

CoS/QoS acc. to ATM PVC or Port

16k MAC addresses per DSLAM

MAC address limitation per port

MAC Anti spoofing (including Service Gateway)

IP Anti spoofing

4096 VLANs

VLAN assignment per PVC/ Port / IP SA/DA and Ether

type

VLAN Translation

VLAN Double Tagging customer/L2CP/in-band

management channel

MAC Address Translation 1:1 for PPPoE and DHCP

Sessions

Storm Control on Subscriber Port (IFX)

Rate limiting for ARP, DHCP, IGMP on DSL port

Routing between in-band Mgmt Channel and out-of-band

Interface

VLAN Stacking (QinQ, user frames w/o tag)

Ethernet-based Forwarding (VLAN Tagging)

TOS/DSCP and .1p Handling for trusted and untrusted

Customers

Port isolation

Link Aggregation (LAG), LACP

Spanning Tree: STP, RSTP, MSTP

Support of Static IP addresses

Flow Control according to 802.3x

Ethernet Ring Protection (ERP)

Multiple ATM PVCs per Line (up to 8)

Per port traffic Policing & Shaping

Egress shaping per Class of Service (802.1p)

DHCP Relay Agent (opt. 82) per PVC

PPPoE Intermediate Agent (opt. 105)

RFC 2684 bridged (VC/LLC encapsulation)

IPoATM / RFC 2684 routed/dynamic

PPPoA-to-PPPoE Translation incl. Protocol Detection

ANCP (L2CP) for ADSL2+, VDSL2 and SHDSL

OAM (F5 loopback, VC RDI)

Remote upgradeability from older software versions

SFP Power Measurements Display

Uptime Counter Display

Remote Testing Capability

Network-wide Profile Management

Uplink Interfaces – Central Unit

100/ 1000Base-T Line Interface electrical

IEEE 802.3u / 802.3z compliant

100/ 1000BASE-T single RJ-45 connector

Supports auto-negotiation

Transmission distance: 100m

Cable: UTP cat.5e (8 poles: four bi-directional pairs)

1000Base-SX Line Interface optical

1000BASE-SX compliant with IEEE 802.3z

Full-duplex operation for Multimode fiber

Transmission distance: 550m with 50 µm fiber

(2km type and 15km type available)

Path attenuation: 7.5dB 10

Output power range: -9.5 ÷ -4 dBm (average)

Input sensitivity: min. -17dBm (typ. -20dBm)

Connector type: LC

1000Base-LX Line Interface optical

1000BASE-LX compliant with IEEE 802.3z

Full-duplex operation for Single Mode Fiber

Transmission distance: about 10km

(20km type and 40km type available, too)

Path attenuation: 10.5 dB

Output power range: -9.5 ÷ -3 dBm (average)

Input sensitivity: min. -20dBm

Cable type: 9/125µm single mode

Transmitter wavelength: 1266 ÷ 1360nm

Laser type: laser diode class 1

Connector type: LC

1000Base-ZX Line Interface optical

1000BASE-ZX compliant with IEEE 802.3z

Full-duplex operation for Single Mode Fiber

Transmission distance: about 80km

Path attenuation: 23 dB

Output power range: 0…5 dBm

Input sensitivity: -3….-23dBm

Cable type: 9/10µm single mode

Transmitter wavelength: 1550nm

Laser type: laser diode class 1

Connector type: LC

Page 4: Multi-ServiceIPDSLAM SURPASS … · 16k MAC addresses per DSLAM MAC address limitation per port MAC Anti spoofing (including Service Gateway) IP Anti spoofing 4096 VLANs VLAN assignment

Line Interfaces – Interface Unit Card

ADSL2+ - 72 port

ADSL functionality (DMT) according ITU-T G.992.1

ADSL2 (G.dmt.bis) functionality (DMT) according ITU-T

G.992.3

ADSL2+ functionality (DMT) according ITU-T G.992.5

ANNEX A, B, I, J, L and M supported

SELT (Single Ended Line Testing)

PSD Mask Shaping for ADSL2+

Bin Deactivation for RFI Disturbers

SHDSL - 48 Port

SHDSL (TC PAM16) according ITU-T G.991.2

SHDSL.bis, 2 and 4-wire and Wetting Current

EFM bonding and ATM M-Pair Mode up to 4 pairs

Line Probing

VDSL2 – 48 Port

Bandplan 998 B and 997

VDSL2 Profiles 8a, 8b, 8d, 12a and 17a

SELT

GE – 10 Port

Subtending of e.g. other IP-DSLAMs

IP Multicast

RFC 1112 IGMPv1

RFC 2236 IGMPv2

RFC 3376 IGMPv3

RFC 826 ARP

1k Multicast Groups

User Access Control & Security

IGMP Proxy

Flow Control

IGMP, DHCP filtering, rate limitation

Denial of Service attack prevention

MAC and IP Anti-spoofing

Configuration & Management System

SNMPv3

ACI-E R4.0

Secure Shell v1/v2

Remote network traffic monitoring with standard SNMP

and RMON protocols

CLI-based shell provides common user interface through

console port or telnet.

Port Mirroring for the purposes of: sniffing, traffic

monitoring, port- based traffic detection

Alarm History

Inventory Export Service

Standards

IEEE 802.1ad

IEEE 802.1D STP (Spanning Tree Protocol)

IEEE 802.1p QoS

IEEE 802.1Q VLAN

IEEE 802.1w RSTP (Rapid Spanning Tree Protocol)

IEEE 802.3

IEEE 802.3ad Link Aggregation

IEEE 802.3u Fast Ethernet

IEEE 802.3x Flow Control

IEEE 802.3z Gigabit

Environmental and Safety Standards

G200 Chassis / focus on Cabinet & Building installation:

ETSI EN 300 019-1-4, class 4.1

M600/M400 Chassis / focus on CO installation:

ETSI EN 300 019-1-3, class 3.2

M1100/G1100/G400 Chassis / CO & Cabinet installation:

ETSI EN 300 019-1-3, class 3.3

Environmental standard compliance:

Mechanics acc. ETS 300 119-1/2/3/4

Power supply interface acc. ETS 300 132-2

ETSI EN 300 386 for EMC and CE label

ETSI ES 201 468 v1.2.1

EN 60950-1:2001 for product safety

ETS 300 753

IEC 825 for radiation safety of laser products

ITU-T K.20 enhanced level

ITU-T K.21 enhanced level for indoor

ITU-T K.27

ITU-T K.31 for indoor

ITU-T K.35 for outdoor

ITU-T K.45 enhanced level for outdoor

89/336/EECEMC Directive

CISPR22:1997 Class A

CISPR22:1997 Class B

EN55022:1998 Class A

EN55022:1998 Class B

EN610000-3-2,3

Telcordia Standards: NEBS Level 3 for CO, GR-487 for

cabinet, GR-1089 for Emissions & Immunity

Page 5: Multi-ServiceIPDSLAM SURPASS … · 16k MAC addresses per DSLAM MAC address limitation per port MAC Anti spoofing (including Service Gateway) IP Anti spoofing 4096 VLANs VLAN assignment

Physical Data hiX 5622/5625/5630/5635

hiX / Horizontal layout with 10 GE star bus architecture

Subrack size (h x w x d)

122 mm x 494 mm x 279mm (23’’ and ETSI) ~ 2,8 U

Subrack size with cables

122 mm x 494 mm x 315mm (h x w x d)

Power supply

2 redundant DC connectors for -48 V DC / -60 VDC

Working between -40,5 ...-72,0 V

Power-consumption

Fully equipped (144ADSL2+ lines): max. 270W

Temperature range

According to ETSI EN 300 019-1-3, class 3.3 (–25 to +55 °C)

For outdoor installation a typical sun radiation add-on of +15 °Cmust

be considered, resulting in an upper temperature limit of +70 °C

hiX 5622 G200

hiX / Vertical layout with 1 GE star bus architecture

Subrack size

536mm x 444.5mm x 279mm (19’’ and ETSI) ~ 12U

Subrack size with cables

536mm x 444.5 mm x 315 mm (h x w x d)

Power supply

2 redundant DC connectors for -48 V DC / -60 VDC

Working between -40,5 ...-72,0 V

Power-consumption

Fully equipped (1080 ADSL2+ lines): max. 1700W

Actual power consumption will depend on the numberof

simultaneous connections and power modes in which these

lines are running (normal/L2/L3)

Temperature range

According to ETSI EN 300 019-1-3, class 3.3 (–25 to +55 °C)

For outdoor installation a typical sun radiation add-on of +15 °C

must

be considered, resulting in an upper temperature limit of +70 °C

hiX 5635 M1100

hiX / Vertical layout with 10 GE star bus architecture

Subrack size (h x w x d)

536 mm x 444,5 mm x 279 mm (19’’ and ETSI) ~ 12U

Subrack size with cables

536 mm x 444,5 mm x 315 mm (h x w x d)

Power supply

2 redundant DC connectors for -48 V DC / -60 V DC

Working between -40,5 ...-72,0 V

Power-consumption

Fully equipped (1008 ADSL2+ lines): max. 1600 W

Actual power consumption will depend on the no. of

simultaneous connections and power modes in which

these lines are running (normal/L2/L3)

Temperature range

According to ETSI EN 300 019-1-3, class 3.3

(–25°C to +55 °C)

For outdoor installation a typical sun radiation add-on of

+15 °C must be considered, resulting in an upper

temperature limit of +70 °C

hiX 5635 G1100

Page 6: Multi-ServiceIPDSLAM SURPASS … · 16k MAC addresses per DSLAM MAC address limitation per port MAC Anti spoofing (including Service Gateway) IP Anti spoofing 4096 VLANs VLAN assignment

hiX /

Horizontal layout with 10 GE star bus architecture

Subrack size (h x w x d)

224mm x 494mm x 279 mm (23’’ and ETSI) ~ 5U

Subrack size with cables

224mm x 494mm x 315 mm (h x w x d)

Power supply

2 redundant DC connectors for -48 V DC / -60 V DC

Working between -40,5 ...-72,0 V

Power-consumption

Fully equipped (288 ADSL2+ lines): max. 550 W

Temperature range

According to ETSI EN 300 019-1-3,

class 3.3 (–25°C to +55 °C)

For outdoor installation a typical sun radiation

add-on of +15 °C must be considered,

resulting in an upper temperature limit of +70 °C

hiX 5625 G400

hiX /

Horizontal layout with 1 GE star bus architecture

Subrack size (h x w x d)

221.5mm x 443,8 mm x 279mm (19’’ and ETSI) ~ 5U

Subrack size including with cables

221.5mm x 443.8 mm x 315mm (h x w x d)

Power supply

2 redundant DC connectors for -48 V DC / -60 VDC

Working between -40,5 ...-72,0 V

Power-consumption

Fully equipped (360 ADSL2+ lines): max. 600W

Temperature range

According to ETSI EN 300 019-1-3, class 3.2 (–5°C to +45 °C)

hiX 5625 M400

hiX / Horizontal layout with 1 GE star bus architecture

Subrack size (h x w x d)

310,3 mm x 443,8mm x 279mm (19’’ and ETSI) ~ 7U

Subrack size with cables

311mm x 443.8mm x 315mm (h x w x d)

Power supply

2 redundant DC connectors for -48 VDC / -60 VDC

Working between -40,5 ...-72,0 V

Power-consumption

Fully equipped (576 ADSL2+ lines): max. 1000W

Temperature range

According to ETSI EN 300 019-1-3, class 3.2 (–5 to +45 °C)

hiX 5630 M600

Page 7: Multi-ServiceIPDSLAM SURPASS … · 16k MAC addresses per DSLAM MAC address limitation per port MAC Anti spoofing (including Service Gateway) IP Anti spoofing 4096 VLANs VLAN assignment

4 slot splitter chassisDimensions149 mm (~3,4U) x 483 mm x 261 mm (h x w x d)

Splitter boards24-port as well as 36-port splitter cards can be mixed in the splitter chassis

8 slot splitter chassisDimensions222 mm (~5U) x 483 mm x 261 mm (h x w x d)

Splitter boards24-port as well as 36-port splitter cards can be mixed in the splitter chassis

16 slots for 36-port splitter and 1 slot with blank panelDimensions440 mm (~10U) x 483 mm x 261 mm (h x w x d)

Splitter boards24-port as well as 36-port splitter cards can be mixed in the splitter chassis

4 slots

horizontal layout

CXU_B / B1 24Gbps 45

CXU_B2 / B21 24Gbps 31

CXU_B3 24Gbps 33

CXU_C 12Gbps 36

CXU_C2 12Gbps 28

Common Interface Unit (CIU) 7

PM_UPL 5

FANModule large – hiX 5635 (M1100/G1100) 120

FANModule small – hiX 5635 (M1100/G1100) 58

FANModule – hiX 5630 (M600) 20

FANModule – hiX 5625 (M400) 12

FANModule – hiX 5622 (G200) 10

ADSL2+ InterfaceUnit - 72-Port Annex A 110

SHDSL Interface Unit – 48-Port 85

VoIP (POTS) Interface Unit – 72-Port 85

VDSL2 Interface Unit – 24ports 74

VDSL2 Interface Unit – 48ports 84

CXU- 24Gbps for hiX 5630/5635 1.1

CXU- 12Gbps for hiX 5630/5625 0.9

Common Interface Unit (CIU) for hiX 5630 0.8

FANModule – hiX 5635 3.1

FANModule – hiX 5630 1.1

FANModule – hiX 5625 0.7

FAN Module – hiX 5622 0.7

M1100/G1100Chassis – hiX 5635 6.5

M600Chassis – hiX 5630 4.6

M400Chassis – hiX 5625 3.8

G400Chassis – hiX 5625 4.0

G200Chassis – hiX 5622 3.7

VDSL2 Interface Unit – 24 Ports 1.0

ADSL2+ InterfaceUnit - 72-Port Annex A 1.2

SHDSL Interface Unit – 48-Port 0.9

Blank panel for hiX 5622/25/30/35 0.1

Total Weight for hiX DSLAMs

hiX 5635: Fully equipped 1 CXU+ 15 IU 30

hiX 5630: Fully equipped 1 CXU+ 8 IU /no red. CXU 17

hiX 5625: Fully equipped 1 CXU+ 5 IU 12

hiX 5622: Fully equipped 1 CXU+ 2IU 9

Splitter Chassis

17 slotsvertical layout

. i

Copyright 2009 Nokia Siemens Networks. All rights reserved.

Other company and product names mentioned herein may be trademarks or trade names of their respective owners.

This publication is issued to provide information only and is not to form part of any order contract.

The products and services described herein are subject to availability and change without notice.

8 slots

horizontal layout

3 3M Services GmbH Zweigniederlassung QNG Ahrensburger Straße 8 30659 Hannover Germany Tel.: (+49)0511/740192-0 Fax: (+49)0511/740192-100 © 3M 2010. All rights reserved. Internet: www.3M-Services.de QHIX56xx 2010-11