Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
Environmental and Social Monitoring Report
Project Number: 50156-001 July 2017
Muara Laboh Geothermal Power Project (Republic of Indonesia)
Semi-Annual Report (January to June 2017) Attachments 1-6
Prepared by PT Supreme Energy Muara Laboh for the Asian Development Bank
This environmental and social monitoring report is a document of the borrower. The views expressed herein do not necessarily represent those of ADB's Board of Directors, Management, or staff, and may be preliminary in nature. Your attention is directed to the “terms of use” section of this website.
In preparing any country program or strategy, financing any project, or by making any designation on or reference to a particular territory or geographic area in this document, the Asian Development Bank does not intend to make any judgments as to the legal or other status of any territory or area.
RD-RSH-RPT-IEE Rev 0 - 28 of July 2017 Page 45
ATTACHMENTS
Attachment 1 : Pictures of Safety Health Environmental Activities
Attachment 2 : Social Activities
Attachment 3 : Biodiversity Action Plan v11
Attachment 4 : Laboratory Analysis Results
Attachment 5 : Hazardous Material Disposal Manifest by Primanru
Attachment 6 : Hazmat Storage Site Verification
Attachment 7 : List of Interviewees for Drilling
Attachment 8 : List of Interviewees for Clerk and Mess Office Girl
Attachment 9 : Approval of Feasibility Study
Attachment 10 : IUPTL
Attachment 11 : Appointment of Temporary Technical Head of Geothermal
Attachment 12 : Building Permit for Permanent Buildings in 2017
Attachment 13 : Building Permit for Temporary Buildings in 2017
RD-RSH-RPT-IEE Rev 0 - 28 of July 2017 Page 46
ATTACHMENT 1
PICTURES OF SAFETY HEALTH ENVIRONMENTAL ACTIVITIES Inspection of the construction of temporary of hazardous material building with representatives from Environmental Office of South Solok
ML-C onsite rehabilitation activities: backfilling of mud pond with drilling cutting waste, covered with top soil and endemic flora.
Construction of Ground Water Monitoring Well at WP-C in September 2016
RD-RSH-RPT-IEE Rev 0 - 28 of July 2017 Page 47
Site Inventarization Inspection and Handover to EPC Contractors
Insitu Site Nursery near WP-F (for Amorphophalus sp and Sampia Tree)
Install Identification Signs to 12 Endemic Tree Breeders
RD-RSH-RPT-IEE Rev 0 - 28 of July 2017 Page 48
Wellpad-F : Clearing Works in Progress
Power plant Area Preparation Works
Construction of Temporary Office Building
RD-RSH-RPT-IEE Rev 0 - 28 of July 2017 Page 49
Sediment Control
Wellpad-D : Repair of HDPE pond Liners prior to drilling activities commenced
Wellpad-D : Construct Lined Drainage
RD-RSH-RPT-IEE Rev 0 - 28 of July 2017 Page 50
Provision of safe access at construction site
RD-RSH-RPT-IEE Rev 0 - 28 of July 2017 Page 51
SHE Induction
Tool Box Meeting
Vehicle Refueling Training to Contractor Workers
RD-RSH-RPT-IEE Rev 0 - 28 of July 2017 Page 52
ATTACHMENT 2
SOCIAL ACTIVITIES
1. Employee Grievance Mechanism
Announcement via email lists
Employee Grievance Box
RD-RSH-RPT-IEE Rev 0 - 28 of July 2017 Page 53
2. Socio Economic Survey and Vulnerability Assessment
3. Consultation with Minang (Adat)
RD-RSH-RPT-IEE Rev 0 - 28 of July 2017 Page 54
4. List of Interviewees for Drilling
RD-RSH-RPT-IEE Rev 0 - 28 of July 2017 Page 55
5. List of Interviewees for Clerk & Mess Girl
Attachment 3
PT SEML GEOTHERMAL PLANT BIODIVERSITY ACTION PLAN (V11)
S/N Phase
Timing And Frequency Of
MonitoringParameters Location Reporting Requirements
1 Pre-Construction General Planning
& Management
All Environmental
Aspects
--- Designate a Site Support Manager (SSM) with responsibility for implementation of the BAP, including
oversight corrective action and BAP implementation auditing.
BOD (Board of Directors) Appointment of Site Support
Manager (SSM) that will
supervise SHE activities at
site prior to commence any
work. SSM also acts as
Geothermal Technical Head
(KTPB) who is responsible
for SHE management as
regulatory requirement for
geothermal operation.
After acceptance of BAP
actions
Required mitigation outlined
within this BAP
Not applicable Not applicable SSM has been appointed in December 2016.
2 Pre-Construction General Planning
& Management
All Environmental
Aspects
--- Implement adaptive management measure SSM (Site Support
Manager), Construction
Manager, and Corporate
SHE Manager
Records of change
management actions
undertaken against each
incident
Ongoing throughout
construction and
operation
Required mitigation outlined
within this BAP
Required locations as
outlined within this BAP
Minutes of any meetings
conducted during
construction and operation
in relation to BAP
implementation and
corrective actions
Each Management of Change process to be
addressed within 4 weeks of incident.
3 Pre-Construction General Planning
& Management
Fauna Mortality Action Plan 1 Develop protocols for the management of injured wildlife, which will include:
1. Process of communication to forestry officers of injured wildlife.
2. Recording procedures for injured wildlife/ investigations.
3. Identification of management of change measures necessary to reduce the risk of future events.
Corporate SHE Manager Corporate SHE Manager to
ensure development of
protocols
After acceptance of BAP
actions
Required mitigation outlined
within this BAP
Not applicable Not applicable Each injured wildlife encounter to be
resolved and closed within 3 days.
4 Pre-Construction Incident
Reporting
Fauna Mortality Action 1 Establish an incident reporting mechanism, including database (map, record), to record injured or
killed wildlife.
Construction Phase: SSM
Operation Phase:
Field Manager
Establishment of an incident
reporting reponse system
and a database to record the
number and type of
injured/killed wildlife.
After acceptance of BAP
actions
Required mitigation outlined
within this BAP
Not applicable Not applicable All wildlife injuries/mortality attributed to
Project actions over Project lifespan is
recorded.
5 Pre-Construction Wildlife Crossing Connectivity Action 1 PT SEML to identify wildlife crossing locations to identify higher risk crossing points along access roads
for which targeted mitigation should be implemented.
Ensure that there is no direct lighting of wildlife crossings.
Construction Phase: SSM
Operation Phase:
Field Manager
i) Corporate SHE Manager to
ensure that study to identify
the needs for temporary
crossing is conducted.
ii) If temporary crossing is
needed, ensure it will be
developed and that no light is
directed onto the crossing.
iii) Wildlife camera trap data
/ photo records to be
collected and analysed
monthly
Once during construction
Wildlife camera traps will
be used on a continuous
basis within 1 year of
crossing establishment.
Not applicable
Wildlife camera trap data /
photo records
Across locations
identified for wildlife
crossings.
Deploy camera traps at
at landing points and
along the length of the
wildlife crossing
Fauna monitoring reports
Fauna monitoring reports
Identification of locations that need wildlife
crossing along access road in 1st semester
2017.
if the CH crossing is needed, the crossing will
be designed and developed within 3 months
after the identification.
Use of wildlife crossing by any one of
identified CH species triggers within 1 year
of crossing establishment.
6 Pre-Construction Clearance Connectivity Action 5 Assess the need for the installation of artificial crossing (crossing bridge) for endangered arboreal
mammals crossing in the Project area, with input from experts on the most appropriate design of
arboreal crossing that takes into consideration technical and safety requirements.
This requirement is to be confirmed prior to the construction of site access road to Wellpad F.
Corporate SHE Manager,
SSM, and Construction
Manager
Stakeholder minutes of
meeting
Prior to commencement
of construction period
Required mitigation outlined
within this BAP
To be determined based
on outcome of
assessment
Not applicable See KPI for #3 above.
Install artificial crossing by end of
construction period (if required).
7 Pre-Construction Clearance Disturbance &
Displacement of
Wildlife
Action 2 Conduct biodiversity surveys for mammal species and flora species of conservation value (including
orchids) before construction of new wellpads. Findings are to be communicated with the site team
and appropriate actions taken where necessary to minimise impacts.
Corporate SHE Manager
Biodiversity experts
Survey reports At least 2 weeks prior to
clearance
Presence/absence,
abundance, ecological
observations, sex, maturity
At proposed sites for new
wellpads
Survey report Zero injured or dead wildlife attributed to
land clearance.
Additional fauna (and flora) study is
conducted prior to the construction of
access road to Wellpad-F.
8 Pre-Construction Clearance Disturbance &
Displacement of
Wildlife
Action 2 Prior to the start of construction at each Project component, ensure that wildlife is shepherded from
the Project area into adjacent refuge areas, and that temporary fencing/hoarding is erected around
construction areas (if required) to limit access to fauna.
Identified wildlife refuge areas during pre-construction and construction activities include:
1. Kerinci Seblat National Park;
2. Adjacent montane and lowland rainforests outside the affected areas.
Upon detection of any dead or injured animal, SSM and Construction Manager shall be notified and
the action suspected to have caused the injury to be suspended. The SSM shall arrange suitably
qualified persons to attend to the animal as soon as practicable. An incident should be logged via an
incident reporting mechanism.
Construction activities shall also proceed with greater caution in the event that any target terrestrial
fauna (CH species triggers, in particular large mammals) are encountered within the construction site.
Construction staff shall notify the SSM and Construction Manager.
SSM and Construction
Manager
Contractor
i) Visual inspections of
hoarding erection
ii) Wildlife shepherding
surveys
Daily following erection of
fencing/hoardings for
each work package
Survey in conjunction
with shepherding
activities
Throughout construction
and/ or operation (if
possible)
Erected fencing/hoardings
(as required)
1. Species requiring
relocation within the Project
component area.
2. Habitat features such as
hollow trees, dens, nests
and roosts.
3. Record all habitat
features observed using a
GPS.
Large terrestrial CH trigger
species such as Sumatran
Serow
Work package
boundaries
Work package area to be
cleared
Refuge areas
Wildlife shepherding
records
Zero injured or dead wildlife attributed to
land clearance.
Monitoring / Inspection / Spot Check Parameters
KPIsTaskAspect, Potential
Impact /IssueBAP Reference
Required MitigationResponsible Person For
Ensuring Action
Implementation
Means Of Verification That
Commitment Has Been Met
9 Pre-Construction Clearance Disturbance &
Displacement of
Wildlife
Action 2 All proposed clearance areas will be marked in the field prior to any vegetation being cleared. The
marking can use spray paint or marking tape. A briefing is to occur with personnel to outlined the
area proposed for clearing.
An inspection is to occur following clearing to determine if clearing has been limited to the identified
clearance area. Any clearing outside of the marked area is to be reported to the SSM and
Construction Manager.
SSM and Construction
Manager
Contractor
Clearance briefing
attendance records
Inspection of cleared areas
During clearance activities Areas marked for clearance Work package area to be
cleared
Daily SHE Inspection
Reports
100% of clearance occurs within marked
cleared area.
10 Pre-Construction Clearance Disturbance &
Displacement of
Wildlife
Action 2 Prior to wildlife shepherding activities, undertake a briefing with all involved personnel so they are
aware of their roles and responsibilities; measures to deal with injured wildlife; occupational health
and safety requirements; and requirements regarding the prohibition of hunting/catching/taking of
fauna and flora. This will include incident reporting measures to relevant forestry authorities and
stakeholders, and the reporting of any individual suspected or caught with fauna and flora to the
relevant authority. Random inspections of personnel arriving and leaving the Project area can be
considered. Refresher training is to occur with new employees.
SSM, Construction
Manager
Clearance briefing
attendance records
Prior to clearance
activities
Number of persons briefed
and particulars
Not applicable 6-monthly EMP
Implementation Reports
100% of contractors, workers and staff
involved in land clearance briefed.
11 Pre-Construction Clearance Restoration Action 8 Establish a site nursery to cultivate native species on site for use in forest restoration activities. Native
seed stock and saplings can be obtained from within the Project area and/or from similar habitat
and/or from other nurseries.
SSM Confirm the presence of site
nursery
Maintain an inventory of
native species cultivated at
the nursery.
Establishment of nursery
Inventory to be
established from
inception of site nursery.
It should be updated
every time a new
individual is added and a
"stocktake" conducted bi-
monthly.
Inventory to include date of
arrival of individual to
nursery, general location
where individual was
derived from. Location data
can range from spatial
coordinates to broader
descriptions (eg near Village
X or an area with similar
habitat) depending on
available resources for
curation.
Designated nursery area
Inventory can be
maintained in a
spreadsheet format.
6-monthly EMP
Implementation Reports
Establishment of 1 on-site nursery prior to
clearance phase.
12 Pre-Construction Biodiversity Offset
Planning
Biodiversity
Offset
BAP 18 Nov 2016:
Action 10
Approximately 51 ha of modified/mixed and forested areas will be permanently cleared for the
Project footprint. An Offsite Biodiversity Offset Design is to be prepared and implemented. The Offset
Plan to be designed using participatory processes with KSNP Management and local communities who
will be included in the implementation as far as possible.
Corporate SHE Manager
Experts
Biodiversity offset plan and
commencement of offset
project
Biodiversity Plan to be
prepared by end 2017
Plan detailed dependent on
offset requirements and
outcome of consultation
To be determined To be determined in
Biodiversity Offset Plan
Offset plan prepared within the construction
period and starts the discussion with KSNP
management in 1st semester 2017.
13 Pre-Construction Water
management
Water extraction
and flows
Prior to water extraction feasibility assessment should be undertaken that considers suitability of the
specific extraction site as well as volume to be extracted. Extraction rates may need to be altered
depending on seasonal conditions and flow rates in order to maintain sufficient base flow and reliant
ecosystems;
Monitoring of aquatic habitats will be undertaken throughout water extraction period to identify if
extraction rates are too great to maintain ecosystem functioning. This may require input from a
specialist;
A management plan will be developed and implemented specific to the aquatic environment and the
extraction;
The extraction pipe will be suitably designed to avoid drawing fish into the pipe leading to mortality.
Corporate SHE Manager
Experts
Determine the extraction
rates according to seasonal
conditions and
To be determined
following further
assessment
To be determined following
further assessment
To be determined
following further
assessment
To be determined following
further assessment
To be determined following further
assessment
14 Construction Clearance Restoration Action 8 Collect native flora seed before land clearance. These seedlings to be cultivated and propagated in a
nursery and maintained until 2020 when forest restoration activities commence onsite.
SSM Confirm the presence of site
nursery
Maintain an inventory of
native species cultivated at
the nursery.
During clearance seed
collection activities
Inventory to include date of
arrival of individual to
nursery, general location
where individual was
derived from. Location data
can range from spatial
coordinates to broader
descriptions (eg near Village
X or an area with similar
habitat) depending on
available resources for
curation.
Designated nursery area
Inventory can be
maintained in a
spreadsheet format.
6-monthly EMP
Implementation Reports
Establishment of 1 on-site nursery prior to
clearance phase.
15 Construction Awareness
Training
Disturbance &
Displacement of
Wildlife
Action 13 Local community engagement will be carried out with villages in the Project catchment to
(i) raise awareness of the conservation value of the KSNP forest;
(ii) encourage local people not to hunt threatened and protected species in the forest, or clear areas
by logging; and
This engagement programme will be developed by PT SEML, in consultation with, the local
government, KSNP Management, and customary leaders. Communities will be engaged formally to
communicate and consult on developments within the Project relevant to them. These meetings are
to be formally minuted.
Corporate SHE Manager,
SSM, and Corporate
External Relations
Manager
Minutes of meetings Yearly Not applicable Not applicable Not applicable Meetings to be held for community
members in villages around project area. All
minutes of meetings to be documented.
16 Construction Transportation Fauna Mortality BAP 18 Nov 2016:
Action 11
Undertake regular monitoring of PT SEML access roads to secure them from poaching activity. SSM, Field Security
Supervisor, Field
Relations, and Corporate
External Relations
Manager
Monitoring records On acceptance of BAP
actions
Signs of poaching activity PT SEML access roads To report to relevant
authorities, including police
department if necessary,
and lodge an incident
internally
Zero incidents of illegal poaching or tree
felling by Company staff.
17 Construction
Operation
Transportation Fauna Mortality Action 1 Company drivers to receive internal defensive driving training that includes commentary driving.
Drivers are required to pass PT SEML's driving test and obtain a company driving license before being
authorised to drive on site.
SSM, SHE Supervisor, and
Contractors
Log of personnel who have
undertaken the driving test
and documentation of
registered drivers within PT
SEML
Prior to commencement
of construction works
Company drivers receiving
training on defensive driving
All company drivers Log of personnel who have
successfully completed
training
100% of all company drivers to possess PT
SEML driving test license
18 Construction
Operation
Transportation Fauna Mortality Action 1 Security and/or SHE staff to conduct speed checks for vehicles using a radar speed gun. Non-
compliance with the speed limit will be reported to the Site Support Manager and appropriate
disciplinary procedures undertaken in accordance with PT SEML policy.
SSM, Security Supervisor,
SHE Supervisor, and
Contractors
Record of date of spot check
occurrence and evidence of
maintained speed log
Monthly spot checks Speed of vehicle Any point within the
access road where speed
limits are in place
Speed logs Zero speeding incidents recorded.
19 Construction
Operation
Lighting Disturbance &
Displacement of
Wildlife
BAP 18 Nov 2016:
Action 4
The following design elements for lighting within the Project area will be implemented:
Lighting will be directed away from vegetated areas and habitats. Upward and directional lighting will
be avoided. Lighting into unintended areas will be avoided. Where lighting is required to be installed
for safety and security purposes, regulatory requirements or best practice for wildlife-friendly lighting
design will be followed.
During construction, lights will not be used outside of construction hours. During operations, general
lighting usage will be consistent with the operating hours of each Project component. Outside of
operating hours, low lux level and downcast lighting will be needed along pathways and roads at levels
sufficient for safety reasons.
Reduce the duration of nocturnal lighting sources by using a timer or movement based sensor system
to turn off lights.
Where permanent lights are employed, ensure that darker passages between lights exist for sensitive
fauna to pass. Automatic dimming to reduce lighting intensity will also be considered.
Avoid using lumination that has a high UV component to reduce impacts on insects.
Avoid using broad spectrum lights.
Installation of light fittings to reduce nocturnal light impacts on habitats in vegetated areas and
habitats outside project area that are close to these night light sources
SSM, Construction
Manager, and Field
Manager
Light monitoring At night, monthly during
construction and
operations
Light intensity (lux) Vegetated areas and
habitats that are close to
these night light sources
Light monitoring records 100% compliance - no light spillage/
directed into forest
20 Construction
Operation
General Planning
& Management
Disturbance &
Displacement of
Wildlife
Action 4 No night works that can disturb wildlife to be undertaken during construction or operation unless
under exceptional circumstances (not inclusive of drilling activities at wellpads and powerplant
activities).
SSM, Construction
Manager, and Field
Manager
Indication in construction
schedule
Monthly spot checks
against construction
schedule where it has
been indicated that no
night work would occur
Occurrence of night work At locations specified in
construction schedule
6-monthly EMP
Implementation Reports
100% compliance - no disruptive night
works undertaken at night.
21 Construction
Operation
Fauna & Flora
Surveys
Monitoring Action 6 Conduct regular monitoring of flora and fauna in Project areas. The surveys will be undertaken by
experts with assistance (including guides) from local villages. The information collected is to be used
as a basis for habitat and population management.
Corporate SHE Manager Updated species database of
the Project area
Surveying, reporting and
mapping to be
undertaken
(i) before construction;
(ii) every 3 years after
operations commence;
and thereafter
Flora (seedlings, saplings,
trees), mammals, birds,
reptiles & amphibians, fish
Flora: Presence of protected
species, pioneer species,
invasive species
Fauna: Presence, abundance
and distribution of species of
conservation significance,
endemic species
Project area using
transects and vegetation
plots where baseline
surveys have been
carried out.
Survey report Not applicable
22 Construction
Operation
Awareness
Training
Disturbance &
Displacement of
Wildlife
Action 12 All construction personnel and PT SEML staff will undertake biodiversity awareness training prior to
commencement of construction to raise their awareness of the:
(i) ecological sensitivity of the site, importance of forest habitats, protected and threatened plants and
animals within the Project area;
(ii) proper protocols to adopt when wildlife is encountered;
(iii) need to be cautious when operating machinery to avoid injury/mortality to fauna; and
(iv) PT SEML's no-tolerance policy on poaching that encompasses both direct and indirect
involvement. This is applicable to both staff and contractors.
All workers and visitors to be educated to ensure that all work places are kept clean and waste is not
left in open areas. All workers will be prohibited from feeding animals.
Refresher training will be provided at every year throughout construction and operation.
SSM, Construction
Manager, Field Manager,
and Corporate SHE
Manager
Training Records Prior to commencement
of works and for all new
workers
Refresher training every
year
Number of workers trained Not applicable Training records maintained Zero incidents of hunting/poaching and
wildlife injury/ mortality by PT SEML
contractors and staff.
23 Construction
Operation
Awareness
Training
Disturbance &
Displacement of
Wildlife
Action 12 Put up and maintain information posters and literature in the PT SEML site office to increase
awareness of ecological issues affecting the Project and the conservation value of the KSNP forest.
SSM, Construction
Manager, Field Manager,
and Corporate SHE
Manager
Placement of posters and
literature in the site office
On acceptance of BAP
actions
Posters and literature at the
PT SEML office
PT SEML site office 6-monthly EMP
Implementation Reports
Refresh posters and literature in site office a
minimum of once a year.
24 Construction
Operation
Incident
Reporting
Disturbance &
Displacement of
Wildlife
Action 1 Compliance with PT SEML environmental protection policy will be managed and monitored by the
SSM. This will include a procedure for reporting incidents by site staff. A recording and evaluation
system will be established and reviewed on a monthly basis. Corrective measures will be taken where
necessary including appropriate actions against infringements.
SSM, Construction
Manager, Field Manager,
and Corporate SHE
Manager
Monitoring reports and
records
On acceptance of BAP
actions
Required specifications
outlined within this BAP
Not applicable 6-monthly EMP
Implementation Reports
100 % compliance with PT SEML
environmental protection policy. 100 % of
incidents reviewed by SHE team every
month and corrective measures
implemented within 2 weeks of review.
25 Construction Fauna & Flora
Surveys
Fauna Mortality Action 1 Regular monitoring of construction areas for signs of potential wildlife conflict, illegal logging and
poaching. Frequency of monitoring to increase if signs of these have been identified
SSM Monitoring reports and
records
Monthly, intensity to
increase based on findings
Signs of wildlife conflict,
illegal logging, poaching (e.g.
new trails and roads into
forest, dead wildlife)
Within Project area Monitoring report 100% of all signs of potential wildlife
conflict, illegal logging and poaching to be
communicated to local forestry officers and
relevant authorities within 3 days.
26 Construction Awareness
Training
Disturbance &
Displacement of
Wildlife
Action 4 Workers to be trained in noise-reduction behaviours such as reducing the drop height of materials,
and turning off equipment and vehicle engines when not in use.
SSM, SHE Supervisor,
Construction Manager.
Contractor and Field
Manager
Training records On acceptance of BAP
actions
Presence of noisy
behaviours
All worksite areas Inspection report 100% of workers trained in noise-reduction
behaviours.
27 Operation Wildlife Crossing Monitoring Action 5 An appropriate monitoring and maintenance programme will be introduced to ensure that the
constructed crossing points/ arboreal crossing bridge is retained in good functional condition.
Inspections will take place at no less than 6 month intervals. NGOs, ecologists and arboreal mammal
experts to be engaged when undertaking this action.
SSM, Construction
Manager, Field Manager.
Inspection records Inspections to occur at six
monthly intervals or less.
Bridge condition, vegetation
structure at wildlife crossing
points, signs of wildlife usage
At crossing points/
arboreal crossing bridges
Inspection record Not applicable
28 Operation Fauna & Flora
Surveys
Monitoring Action 6 Data from camera trap surveys, transects and community monitoring to be used to measure long
term population changes and trends for key species (such as the Malayan Sunbear, Golden Cat,
Sumatran Serow).
PT SEML will liaise with local authorities and experts to provide any relevant ecological monitoring
data to integrate in the long term monitoring and management of the broader area, KNSP, and with
the other surrounding developments.
SSM and Corporate SHE
Manager
Review of long term
monitoring records
Every 3 years and
intensity to change based
on findings
Ecological monitoring data
for key species, including CH
trigger species
Project Area Monitoring Records and
Minutes of Meetings
Continued utilisation of Project area by CH
trigger species over Project construction
and operation.
29 Post-Construction
Operation
Habitat
Rehabilitation
Restoration Action 8 Consultation will be undertaken with relevant stakeholders in order to determine the composition and
type of planting to be achieved. Implementation will then be undertaken by PT SEML and if needed
assistance will be sought from experts.
Corporate SHE Manager
Experts
Minutes of meeting Prior to commencement
of construction period
Required mitigation outlined
within this BAP
To be determined based
on outcome of
consultation
Annual Implementation
Report
Not applicable
30 Post-Construction
Operation
Habitat
Rehabilitation
Restoration Action 8 and
Action 10
A community based forest restoration project may be developed to engage local communities to
participate in forest restoration activities activities, such as weeding, replanting, maintenance and
seedling propagation.
Corporate SHE Manager Implementation of the
community based forest
restoration project
To be established within 6
months of
commencement of
Project operation and
reviewed on a 12 monthly
basis
Number of community
members engaged
Within Project area
and/or within Project
vicinity (subject to
permission from National
Park)
Annual Implementation
Report
50% of restoration workforce employed
from local communities.
31 All Phases General Planning
& Management
Fauna Mortality Action 9 Install warning signs targeted at poachers and illegal loggers at the border of the buffer area of Kerinci
Seblat National Park (KSNP).
SSM and Security
Supervisor
Installation of warning signs
and attendance at joint
patrols
Upon acceptance of BAP
actions
Warning signs at border of
buffer area of KSNP
Border of buffer area at
KSNP
Annual Implementation
Report
Warning signs at the boundary of the
project area with TNKS
32 All Phases General Planning
& Management
Fauna Mortality Action 9 Establish a communication system with the local authorities and report to authorities immediately
any signs of illegal hunting and deforestation, wildlife conflict and forest fires within KSNP.
Furnish this report with photographic documentation where possible and the date and time of
observation. Incident also to be recorded via PT SEML's incident reporting mechanism.
SSM, Security Supervisor,
and Field Relations
Supervisor
Establishment of a
communication system with
reporting parameters
Upon acceptance of BAP
actions
Protocol to be determined
and agreed with local
authorities
Around worksite areas
and buffer area at KSNP
Survey report Each incident to be submitted to local
authority within 3 days.
33 All Phases Fauna & Flora
Surveys
Monitoring /
Engagement
Action 7 Set up a habitat mapping database following the pre-construction monitoring work to store all
biodiversity monitoring data. From this database:
(i) Prepare habitat maps for the project site using aerial imagery obtained via satellite or drone.
(ii) As part of the evaluation of management action, analyse results of field surveys, biodiversity
monitoring, and opportunistic sightings to understand more detailed and specific distribution of
species.
The database is to be shared between PT SEML, KSNP, and ecologists. It is to be updated annually or
when major findings from surveys call for updates.
Corporate SHE Manager Establishment of database Database set up to be
verified after pre-
construction monitoring
work
Required specifications
outlined within this BAP
Not applicable Annual Implementation
Report
Database to be established within 1 year of
construction commencement.
34 All Phases Transportation Fauna Mortality Action 3 Control access road users by constructing security gates to restrict access of vehicles. Security gates
are to be manned by at least 1 security officer 24 hours per day who will record the particulars (name,
address, village, vehicle registration number, personal identification number) of all vehicles who are
allowed into the access road. As per PT SEML's security management system, an ID badge to be
issued to visitors upon arrival and returned upon departure; company staff should already possess a
Company ID Badge that must be displayed upon arrival. Visitors must also be accompanied by a
company representative at all times. The security officers should be trained to identify behaviour
associated with poachers and vehicle searches. The security gate should be equipped with 24 hour
CCTV cameras.
For people that have cleared and are utilising areas within the project concession, security to
investigate if clearance is conducted in a legal manner. If yes, these individuals to be issued with a
label (distinguished from staff), that grants them continued access into the site.
SSM and Security
Supervisor
Proof of well-maintained
access log
Training records of security
officers
Monthly review of access
log
Required specifications
outlined within this BAP
At road access points Non compliance to be
addressed on the spot and
if necessary, raised at
company meetings and
minuted
Zero unregistered vehicles within PT SEML
premises
35 All Phases Transportation Vegetation
Clearance
Action 11 Conduct regular patrols of at least every month of the project area to identify encroachment and
burning/land clearing by residents. Patrols to be undertaken by PT SEML with involvement of the
police and government staff. Where it is identified that local people have entered and undertaken
illegal logging or poaching, work with local authorities to report and investigate the breach.
As per the MoU Program Perlindugan dan Pengamanan Hutan, PT SEML shall facilitate and finance
reasonable operating costs relating to patrol activities and requisite infrastructure/equipment.
SSM, Security Supervisor,
Field Relations, and
Corporate External
Relations Manager
Log of the results of regular
patrols
During construction and
operation
Regular patrols undertaken Along the Project Area
boundary and adjacent
land
To report to relevant
authorities, including police
department if necessary,
and lodge an incident
internally
Zero incursion into Project Area.
36 All Phases Transportation Vegetation
Clearance
Action 7 Conduct regular drone flights at least every year to monitor clearance of vegetation within the project
area. Where clearing activity is identified , it is to be investigated and information passed to local
police and forestry department officials.
SSM and Corporate SHE
Manager
Assessment of vegetation
clearance within the project
boundary
During construction and
operation
Drone flight every year 500m of the project
footprint and/or within
Project catchment area
To report to relevant
authorities, including police
department if necessary,
and lodge an incident
internally
Updated aerial map every year.
Report all new clearance of vegetation
within the project area.
37 Pre-Construction Fauna & Flora
Surveys
Invasive Species Action 8 Undertake surveys to identify locations where invasive species are particularly abundant and maintain
an inventory. Where necessary, work with specialists to develop a plan to prevent invasive speices
introduction and/or proliferation due to Project activities.
SSM and Corporate SHE
Manager
Survey report and inventory
development
During construction and
operation
Species, abundance, GPS
location
Around worksite areas, in
particular area where
restoration is targeted to
occur
Survey report Map of invasive species aggregations prior
to March 2018
38 All Phases General Planning
& Management
Vegetation
Clearance
--- Education of local people and restriction of clearing is to be undertaken in conjunction with KSNP
within the local area
SSM and Corporate SHE
Manager
Meeting records, including
details such as village visited,
number of people trained
1 year after acceptance of
BAP actions
Not applicable Not applicable Meeting records Reduction in clearing incidents by local
people 5 years from commencement of
operation.
39 All Phases General Planning
& Management
Ecosystem
Services
--- Conduct interviews with local people regarding their ecosystem service use within the Project Area
and AoI.
SSM and Corporate SHE
Manager
Meeting records 1 year after acceptance of
BAP actions
Not applicable Not applicable Meeting records List of ecosystem services used by local
residents, utilisation profile according to
each village
40 All Phases General Planning
& Management
Vegetation
Clearance
--- Monitor land clearing by local people. If land available for cultivation is reduced and impacts recorded
to livelihoods, measures are to be assessed and undertaken to include alternatives.
SSM and Corporate SHE
Manager
MoU Implementation Report Monthly spot checks Locations of land cleared
Area of land cleared
Individuals/ village
responsible
Within Project Area MoU Implementation
Report
Reduction in clearing incidents by local
people 5 years from commencement of
operation.
Action items:SN Item Responsibility Additional Parties Date to be started/completed Frequency
1 Appoint a Site Support Manager to supervise SHE aspects at site BOD Not Applicable December 2016 1 Time
2 Implement adaptive management measure SSM Not Applicable March 2017 1 Time, each incident
3 Develop protocols for the management of injured wildlife Corporate SHE Manager Not Applicable March 2017 1 Time, each incident
4 Establish an incident reporting mechanism SSM Not Applicable March 2017 1 Time, each incident
5 Identify wildlife crossing points SSM experts Aug-17 1 Time
6 Assess the need for the installation of artificial crossing for endangered arboreal mammals Corporate SHE Manager experts Sep-17 1 Time
7 Conduct a flora and fauna survey prior to construction of wellpad Corporate SHE Manager experts February 2017 1 Time
8 Wildlife shepherding activities Construction Manager Contractors March 2017 1 Time
9 Mark area to be cleared Construction Manager Contractors March 2017 1 Time
10 Prior to wildlife shepherding activities, undertake a briefing with all involved personnel Construction Manager Contractors March 2017 1 Time
11 Establish a site nursery SSM Not Applicable March 2017 1 Time
12 Develop a comprehensive Offsite Biodiversity Offset Plan Corporate SHE Manager experts end of 2019 1 Time
13 Conduct a water extraction pre-feasiblity assessment Corporate SHE Manager experts end of 2019 1 Time
14 Collect native flora seed before land clearance SSM experts March 2017 1 Time
15 Local community engagement to raise awareness of the conservation value of KSNP forest SSM experts March 2017 Yearly
16 Undertake daily monitoring of PT SEML access roads to secure them from poaching activity SSM Not Applicable March 2017 Daily
17 Company drivers to receive internal defensive driving training SSM Contractors March 2017 Yearly
18 Conduct speed check SSM Not Applicable March 2017 Monthly
19 Lighting management Construction Manager Contractors March 2017 Monthly
20 Ensure night works will not disturb wildlife Construction Manager Contractors March 2017 Daily
21 Conduct regular monitoring of flora and fauna in Project areas Corporate SHE Manager experts End 2019 Every 3 years
22 All construction personnel and PT SEML staff will undertake biodiversity awareness training Construction Manager Contractors March 2017 1 time
23 Put up and maintain information posters and literature on ecological awareness SSM Not Applicable March 2017 Every year
24 Monitor compliance with PT SEML environmental protection policy SSM Not Applicable March 2017 Monthly
25 Monitor construction areas for signs of potential wildlife conflict, illegal logging and poaching SSM Not Applicable March 2017 Monthly
26 Workers to be trained in noise-reduction behaviours SSM Contractors March 2017 1 Time
27 Crossing points/ arboreal crossing bridge is retained in good functional condition SSM Not Applicable Every 6 months
28 Measure long term population changes and trends for key species Corporate SHE Manager experts end of 2019 Every 3 years
29 Consultation relevant stakeholders to determine the composition and type of planting to be achieved Corporate SHE Manager experts end of 2019 1 Time
30 Develop a community based forest restoration project Corporate SHE Manager experts, local communities end of construction Yearly
31 Install warning signs regarding hunting and poaching at the border of the buffer area of KSNP SSM KSNP March 2017 1 Time
32 Establish a communication system with the local authorities and report illegal hunting / logging. Support KSNP staff for hunting and poaching management. SSM Forestry Office, Police March 2017 Each incident
33 Develop and update habitat mapping database Corporate SHE Manager experts Mar-18 Yearly
34 Construct security gates to restrict access of vehicle SSM Not Applicable March 2017 1 Time
35 Conduct regular patrols of the project boundary SSM Not Applicable March 2017 Monthly
36 Conduct regular drone flight Corporate SHE Manager Not Applicable March 2017 Yearly
37 Conduct invasive species surveys Corporate SHE Manager experts Dec-17 Every 3 years
38 Education of local people and restriction of clearing is to be undertaken in conjunction with KSNP within the local area SSM Not Applicable Mar-18 Yearly
39 Conduct interviews with local people regarding their ecosystem service use within the Project Area and AoI Corporate SHE Manager Not Applicable Dec-17 1 Time
40 Monitor land clearing by local people Corporate SHE Manager Not Applicable Dec-17 Yearly
Estimated Budget (2016 USD Values) Year 1S/N Task Rate ($USD Per Annum) Consultant Requirement Consultant Cost Capital Equipment Capital Equipment Cost Estimated FTE Labour Cost Total
1 Appoint a Site Support Manager to supervise SHE aspects at site 7034.56 Office support 1,000.00$ 1 7,034.56$ 8,034.56$
2 Implement adaptive management measure 7034.56 0.0192 135.28$ 135.28$
3 Develop protocols for the management of injured wildlife 7034.56 0.0385 270.56$ 270.56$
4 Establish an incident reporting mechanism 7034.56 0.0192 135.28$ 135.28$
5 Identify wildlife crossing points 7034.56 0.0577 405.84$ 405.84$
6 Assess the need for the installation of artificial crossing for endangered arboreal mammals 7034.56 Biodiversity survey for arboreal crossing 5,000.00$ 0.1538 1,082.24$ 6,082.24$
7 Conduct a flora and fauna survey prior to construction of wellpad 7034.56 Biodiversity survey for mammal and flora species prior to new wellpad construction 12,500.00$ 0.0769 541.12$ 13,041.12$
8 Wildlife shepherding activities 7034.56 0.0192 135.28$ 135.28$
9 Mark area to be cleared 7034.56 0.0192 135.28$ 135.28$
10 Prior to wildlife shepherding activities, undertake a briefing with all involved personnel 7034.56 0.0192 135.28$ 135.28$
11 Establish a site nursery 7034.56 Nursery 5,000.00$ 1 7,034.56$ 12,034.56$
12 Develop a comprehensive Offsite Biodiversity Offset Plan 7034.56 Biodiversity Offset Plan 20,000.00$ 0 -$ 20,000.00$
13 Conduct a water extractioon prefeasibility assessment 7034.56 Water extraction assessment $15,000 -$ 15,000.00$
14 Collect native flora seed before land clearance 7034.56 Seed collection 1,000.00$ 0.0769 541.12$ 1,541.12$
15 Local community engagement to raise awareness of the conservation value of KSNP forest 7034.56 Local community 10,000.00$ OHP 2,000.00$ 0.0577 405.84$ 12,405.84$
16 Undertake daily monitoring of PT SEML access roads to secure them from poaching activity 7034.56 0.0769 541.12$ 541.12$
17 Company drivers to receive internal defensive driving training 7034.56 0.0577 405.84$ 405.84$
18 Conduct speed check 7034.56 Radar Speed Gun 2,000.00$ 0.0769 541.12$ 2,541.12$
19 Lighting management 7034.56 0.0769 541.12$ 541.12$
20 Ensure night works will not disturb wildlife 7034.56 0 -$ -$
21 Conduct regular monitoring of flora and fauna in Project areas 7034.56 Yearly flora and fauna monitoring cost (2016 : USD27k by Greencap and USD7.5k/year) 34,500.00$ Camera Traps 5,000.00$ 0 -$ 39,500.00$
22 All construction personnel and PT SEML staff will undertake biodiversity awareness training 7034.56 0.0769 541.12$ 541.12$
23 Put up and maintain information posters and literature on ecological awareness 7034.56 Posters and literature 2,000.00$ 0.0192 135.28$ 2,135.28$
24 Monitor compliance with PT SEML environmental protection policy 7034.56 0.0192 135.28$ 135.28$
25 Monitor construction areas for signs of potential wildlife conflict, illegal logging and poaching 7034.56 0.0192 135.28$ 135.28$
26 Workers to be trained in noise-reduction behaviours 7034.56 0.0577 405.84$ 405.84$
27 Crossing points/ arboreal crossing bridge is retained in good functional condition 7034.56 0.0192 135.28$ 135.28$
28 Measure long term population changes and trends for key species 7034.56 Camera Traps 5,000.00$ 0.0192 135.28$ 5,135.28$
29 Consultation relevant stakeholders to determine the composition and type of planting to be achieved 7034.56 Stakeholders 5,000.00$ 0.0192 135.28$ 5,135.28$
30 Develop a community based forest restoration project 7034.56 Community forest restoration project 10,000.00$ 0.0192 135.28$ 10,135.28$
31 Install warning signs regarding hunting and poaching at the border of the buffer area of KSNP 7034.56 Signs to discourage poaching and logging 2,500.00$ 0.0577 405.84$ 2,905.84$
32 Establish a communication system with the local authorities and report illegal hunting / logging. Support KSNP staff for hunting and poaching management. 7034.56 Contribution to KSNP Patrols 10,000.00$ 0.0000 -$ 10,000.00$
33 Develop and update habitat mapping database 7034.56 See # 34 0.0192 135.28$ 135.28$
34 Construct security gates to restrict access of vehicle 7034.56 0.0192 135.28$ 135.28$
35 Conduct regular patrols of the project boundary 7034.56 Gates, Office, CCTV 45,000.00$ 0.0192 135.28$ 45,135.28$
36 Conduct regular drone flight 7034.56 15,000.00$ 0.0577 405.84$ 15,405.84$
37 Conduct invasive species surveys 7034.56 Drone 6,000.00$ 0.0192 135.28$ 6,135.28$
38 Education of local people and restriction of clearing is to be undertaken in conjunction with KSNP within the local area 7034.56 Join patrol with Forestry, Police, KSNP (along with #31) 0.0192 135.28$ 135.28$
39 Conduct interviews with local people regarding their ecosystem service use within the Project Area and AoI 7034.56 15,000.00$ 0.0192 135.06$ 15,135.06$
40 Monitor land clearing by local people 7034.56 0.0192 135.06$ 135.06$
128,000.00$ 85,500.00$ 3.3269 23,403.44$ 236,903.44$
Figure Number Title
Figure 1 Survey Locations for Fauna Monitoring
DAILY INSPECTION REPORT
Project: Inspected by:
Inspection No:
Date:
Time:
PART A: GENERAL INFORMATION
Weather: Sunny Fine Cloudy Rainy
Temperature: °C
Humidity: High Moderate Low
Wind: Strong Breeze Light Calm
PART B: DAILY INSPECTION CHECKLIST
Tick where applicable
Yes No Follow-Up Not Applicable Photo ID/ Remarks
Section 1: Site Clearance Activities
1.01 Have fencing/hoarding been erected around
construction areas according to wildlife
shepherding strategy?
1.02 Are there holes in the fencing/hoarding where
wildlife may enter?
1.03 Has the contractor checked the weather forecast
and no storm events are forecasted to occur for
the day?
2.04 Has the area to be cleared been inspected by a
wildlife expert?
2.05 Has a briefing been carried out prior to clearance
involving all personnel so that each individual is
aware of his/her role, measures to deal with
injured wildlife, occupational health and safety
requirements and PT SEML's environmental
policy?
2.06 Have areas to be cleared been clearly marked in
the field?
2.07 Has clearing occurred outside of the demarcated
areas?
Section 2: Hunting & Poaching
2.01 Are there any signs of poaching, illegal logging,
wildlife conflict along access roads (eg. Dead
animals, new undesignated trails created,
unregistered stationary vehicles)?
Section 3: Waste Management
3.01 Is licensed waste collector engaged for waste
collection and disposal
3.02 Has there been illegal disposal of construction
waste? (if yes, specify location)
3.03 Is recycling being carried out?
3.04 Is waste disposed of in allocated waste bins and
areas?
3.05 Are the waste bins overflowing?
Section 4: Water Pollution Prevention
4.01 Does every drilling team and well pad have a spill
management and containment kit?
4.02 Are there any leaks from tanks used to store
drilling fluids and cuttings?
4.03 Are there any signs of oil leakage or spillage along
transportation routes?
4.04 Are there any signs of oil leakage or spillage at
worksites?
PART C: REPORTING
Overall Comments
Corrective Actions and Responsibilities
PART D: PHOTOLOG
Photolog
Item Number & Description Comments by Contractor Closed Out/
Signed off
E.g. Item 2.01 - A patch of forest by the side of the
access road was observed to have been logged.
Site Photo Recommended Measures,
Follow-up Actions
INSPECTION TEMPLATE
Project: Inspected by:
Inspection No:
Date:
Time:
PART A: GENERAL INFORMATION
Weather: Sunny Fine Cloudy Rainy
Temperature: °C
Humidity: High Moderate Low
Wind: Strong Breeze Light Calm
PART B: EMMP INSPECTION CHECKLIST
Please tick where applicable
Yes No Follow-Up Not Applicable Remarks/ Details of Item
Section 1: General Planning & Management
1.01 Is there a designated point of contact for PT SEML
in the local forestry department?
1.02 Has an incident reporting mechanism with a GIS
database been developed?
1.03 Have investigations been undertaken for these
incidents, and have corrective measures been
identified or implemented?
1.04 Have experts been engaged with respect to
wildlife crossings and biodiversity surveys?
1.05 Do all company drivers have a PT SEML approved
license?
Section 2: Land Clearance
2.01 Is there an injured animal protocol in place?
2.02 Has there been any dead or injured wildlife found
during land clearance?
2.03 Has a site nursery been established?
2.04 Are native species being cultivated at the site
nursery?
2.05 Are there mulch or erosion control blankets at
cleared sloped areas?
2.06 Is vegetation being transported out of the Project
via a covered vehicle?
Section 3: Stakeholder Engagement
3.01 Has a biodiversity offset plan been developed?
3.02 Has this plan been agreed with with all
stakeholders?
Have stakeholders been consulted on restoration
activities?
3.03 When was the last formal community engagement
event?
Date:
3.04 Were all affected villagers and interested
stakeholders identified during the baseline phase
invited to the event?
3.05 Are meeting minutes being uploaded to a public
domain?
3.06 Are they uploaded within 2 weeks of each
meeting?
3.07 Is a grievance mechanism in place?
3.08 Has any grievances been aired?
3.09 Is there any past/ongoing community based
programme? If so, please specify.
Section 4: Wildlife Crossings
4.01 Are wildlife crossing installations well maintained?
4.02 Is lighting directed onto wildlife crossings?
4.03 Has there been utilisation of wildlife crossings by
fauna?
4.04 Is there a monitoring and maintenance
programme to ensure wildlife crossings continue
to be ecologically functional?
Section 5: Transportation
3.01 Have speed checks been conducted by security
and SHE staff?
3.02 Have there been any incidences of speeding and
have these been escalated to the Field Support
Manager?
3.03 Are there any idling vehicles and equipment?
Section 6: Lighting
6.01 Is lighting directed away from vegetated areas and
habitats?
6.02 (Construction Phase) Are lights being used outside
of construction hours?
(Operation Phase) Is general lighting usage
consistent with the operating hours of each
Project component?
6.03 Is there a timer or movement-based sensor system
for nocturnal lights?
6.04 Are there darker passages between permanent
lights for fauna to pass?
6.05 Have broad spectrum lights been used?
6.06 Are lux levels less than 100 lux within the forest,
20 m from each wellpad?
6.07 Apart from drilling activities at wellpads and
powerplant activities, have other forms of work
been undertaken at night?
Section 7: Awareness Training
7.01 Have all staff been trained in appropriate
responses for unplanned events such as well
blowouts and pipeline failures?
7.02 Have all construction personnel and PT SEML staff
undergone biodiversity awareness training prior to
commencement of construction?
7.03 Are there information posters and literature in the
PT SEML site office about ecological issues
affecting the Project and the conservation value of
the KSNP forest?
7.04 Are there any signs of oil leakage or spillage at
worksites?
7.05 Have all workers been trained in noise-reduction
behaviours?
Section 8: Monitoring
8.01 Have all staff been trained in appropriate
responses for unplanned events such as well
blowouts and pipeline failures?
8.02 Are there any signs of oil leakage or spillage along
transportation routes?
8.03 Are there any signs of oil leakage or spillage at
worksites?
8.04 Has the working area encroached onto adjacent
forest?
8.05 Has there been an increase in the number and
extent of temporary access routes? If yes, specify
reasons.
8.06 Is the level of noise in forest habitat within 20 m of
well pads less than 50 dBA?
8.07 Are all vehicles on access roads registered with the
security office?
8.08 Have there been any wildlife incidents with the
power plant and associated facilities (transmission
line route)?
8.09 Is data from biodiversity surveys and monitoring
available to researchers, universities, NGOs and
forestry officers on a public domain?
8.1 Has a survey of invasive species been undertaken
and an inventory generated?
Section 9: Restoration
9.01 Is a specialist on-board to provide guidance on
forest restoration activities?
9.02 Is up to 50% of the restoration workforce made up
of individuals from local communities?
9.03 Has any CH trigger species been recorded using
the restored forest area?
Section 10: Hunting & Poaching
10.01 Have warning signs been installed at the border of
the buffer area of KNSP?
10.02 When was the last joint patrol between PT SEML
and local authorities?
Date:
10.03 When was the last patrol of the project boundary? Date:
10.04 When was the last drone flight to monitor
clearance of vegetation within 1 km of all access
roads?
Date:
PART C: REPORTING
Overall Comments
Corrective Actions and Responsibilities
Wildlife Shepherding ProtocolSEML will assemble a team comprising ecologists, veterinarians, local wildlife experts, wildlife handlers and hoarding Contractors to carry out the wildlife shepherding activities.
In addition, there is the possibility of involving volunteers from nature groups in this effort. All personnel involved will be briefed on the details of this plan and their respective
roles before field activities begin. Personnel will also be equipped with mobile communication devices on the field to ensure that lines of communication
are maintained during field activities and that the appropriate persons (e.g. veterinarians, wildlife handlers) are able to respond to exigencies in a timely manner.
The general approach to wildlife shepherding that will be undertaken is a combination of the following activities, which may be scheduled during daylight
hours only (i.e. 8am to 6pm):
i) installation of hoarding, which will function as a drift fence to guide target terrestrial fauna in the intended direction of movement and as a barrier to prevent wildlife
displacement onto adjacent roads;
ii) systematic pattern of walking through the site, starting from the area furthest from and then gradually moving towards the identified refuge area, in order to shepherd
wildlife in an intended direction of movement towards adjacent refuge habitats, and;
iii) in conjunction with (ii), the site will be carefully surveyed to check for the presence of target fauna species and any active dens.
In order for the above-described approach to be effective, it is recommended that activities (ii) and (iii) be carried out repeatedly over a course of up to three weeks
for a site no larger than twenty hectares. At the end of this duration, the site has to be inspected by an ecologist to ensure that no target fauna and active dens remain.
Thereafter, gaps in the hoarding shall be closed as soon as practicable so as to prevent target terrestrial fauna from returning to the site.
In the event that any target fauna are encountered during this process, the following actions which have been developed with the consideration
of reducing stress to fauna while ensuring the effectiveness of the shepherding exercise shall be taken:
i) Fauna from Category A: Category A comprises highly mobile fauna for which a passive shepherding approach is expected to be effective. Therefore, when fauna from Category
A are encountered, personnel should remain in place to allow fauna to move on their own accord. Generation of mild human noise disturbance (e.g. talking loudly) may be used
to encourage fauna movement. However, no attempt should be made to capture or handle these species, unless the animal is visiblyinjured in which case experienced wildlife
handlers will carefully capture the animal for immediate veterinary attention. If any individual fauna does not move on its own after sufficient time (i.e. up to one hour) has
passed, the area where the individual is located should be GPS-marked and left overnight to provide additional opportunity for the individual to
move on its own accord. Personnel shall return to the GPS-marked location on the following day to inspect the area. This process will be repeated until the individual has
moved.
ii) Fauna from Category B: Category B comprises fauna for which a passive shepherding approach is expected to be unsafe and/or ineffective in guiding the individual fauna to
move in an intended direction. Therefore, a capture-and-release approach will be needed to ensure safe relocation of these fauna from the site prior to construction. In the
event that fauna from Category B are encountered, experienced wildlife handlers will carefully capture the animal for subsequent assessment and microchipping (where safe
and possible) by a veterinarian. Where sensitive fauna (i.e. Sunda Pangolin) and venomous snakes from Category B are concerned, their capture shall only be carried out by
designated wildlife handlers who have been trained in the appropriate handling techniques.
As stated, the above-described approach will apply to target terrestrial fauna. In addition, it is envisaged that arboreal and aerial species shall generally be able to continue
utilizing remnant habitats on the site during construction, and will not be excluded by the installed hoarding. These actions are as follows:
i) An ecologist shall inspect the tree for the presence of fauna, inhabited tree hollows, and nests.
ii) In the event that the presence of arboreal mammals and herpetofauna, birds and/or bats are detected on the tree, tree felling or transplanting must be postponed until the
animal has left the tree on its own accord.
iii) In the event that an inhabited tree hollow is identified, tree felling or transplanting must be postponed until the animal has left the hollow on its own accord and the
entrance to the hollow has been sealed to prevent re-entry.
iv) Tree felling or transplanting shall not occur during the prime breeding season for local avifauna, i.e. the months from approximately mid- March to July annually. In any case,
if active nests are detected on the tree, nests shall be left undisturbed until nesting activities have been completed (i.e. the young have left the nest). In addition, inactive nests
shall be removed to minimize the possibility of a new nesting attempt. Tree felling or transplanting shall occur only when no active nests are present on the tree.
v) Notwithstanding the aforementioned actions, after tree felling has occurred, an ecologist shall thoroughly search the fallen tree for any injured or trapped fauna that may
have gone undetected. In the event that injured or trapped fauna are found, immediate veterinary attention shall be administered.
Attachment 4
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-01/UA/06/2017 Uraian contoh : Udara Ambien U1. Camp Site Office (AQ-4B) Koordinat : S 01º 36’ 35,6” E 101º 8’ 44‚6” Metode pengambilan contoh : SNI 19-7119.6-2005 Tanggal diambil : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
Temperatur : 28 - 29 0C Arah Angin Dominan dari : Timur Kelembaban : 69 - 75 %RH Kecepatan Angin : 1,0 km/jam Cuaca : Berawan
Hasil Pengujian
NO PARAMETER WAKTU BAKU SATUAN HASIL METODE
PENGUKURAN
MUTU*)
1
Sulfur Dioksida (SO2) **) 1 Jam 900 Bg/Nm3 22
SNI 19-7119.7-2005 24 Jam 365 Bg/Nm3 - 2 Karbon Monoksida (CO) **) 1 Jam 30.000 Bg/Nm3
3.437 SNI 7119.10-2011 24 Jam 10.000 Bg/Nm3 -
3
Nitrogen Dioksida (NO2) **)
1 Jam 400 Bg/Nm3 20 SNI 19.7119.2.2005 24 Jam 150 Bg/Nm3 -
4 Oksidan (O3) **) 1 Jam 235 Bg/Nm3 26 SNI 19-7119.8-2005 5 Hidrokarbon (HC) **) 3 Jam 160 Bg/Nm3 107 SNI 7119.13-2009 6 Debu (TSP) 24 Jam 230 Bg/Nm3
- 18-2/IK/NA (Gravimetri) 1 Jam - Bg/Nm3 43
7
PM10 (Partikel < 10 Bm)
24 Jam 150 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 23
8
PM2,5 (Partikel < 2,5 Bm)
24 Jam 65 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 12
9 Timbal (Pb) 24 Jam 2 Bg/Nm3 - 18-3/IK/NA (AAS) 1 Jam - Bg/Nm3 <0,1
Keterangan : *) = PPRI No. 41 Tahun 1999 Baku Mutu Udara Ambien Nasional **) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDNN = Satuan Volume Hisap Udara Kering dikoreksi pada Kondisi Normal (25°C, 76 cmHg)
Pengukuran Debu (TSP), PM10, PM2,5 dan Timbal (Pb) dilakukan sesaat sesuai permintaan pelanggan < = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 1 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-02/UA/06/2017 Uraian contoh : Udara Ambien U2. Area PLPT (AQ-2B) Koordinat : S 01º 37’ 40,1” E 101º 07’ 52‚6" Metode pengambilan contoh : SNI 19-7119.6-2005 Tanggal diambil : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
Temperatur : 31 0C Arah Angin Dominan dari : Barat Kelembaban : 64 %RH Kecepatan Angin : 1,3 km/jam Cuaca : Cerah
Hasil Pengujian
NO PARAMETER WAKTU BAKU SATUAN HASIL METODE
PENGUKURAN
MUTU*)
1
Sulfur Dioksida (SO2) **) 1 Jam 900 Bg/Nm3 20
SNI 19-7119.7-2005 24 Jam 365 Bg/Nm3 - 2 Karbon Monoksida (CO) **) 1 Jam 30.000 Bg/Nm3
3.391 SNI 7119.10-2011 24 Jam 10.000 Bg/Nm3 -
3
Nitrogen Dioksida (NO2) **)
1 Jam 400 Bg/Nm3 19 SNI 19.7119.2.2005 24 Jam 150 Bg/Nm3 -
4 Oksidan (O3) **) 1 Jam 235 Bg/Nm3 36 SNI 19-7119.8-2005 5 Hidrokarbon (HC) **) 3 Jam 160 Bg/Nm3 103 SNI 7119.13-2009 6 Debu (TSP) 24 Jam 230 Bg/Nm3
- 18-2/IK/NA (Gravimetri) 1 Jam - Bg/Nm3 39
7
PM10 (Partikel < 10 Bm)
24 Jam 150 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 21
8
PM2,5 (Partikel < 2,5 Bm)
24 Jam 65 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 11
9 Timbal (Pb) 24 Jam 2 Bg/Nm3 - 18-3/IK/NA (AAS) 1 Jam - Bg/Nm3 <0,1
Keterangan : *) = PPRI No. 41 Tahun 1999 Baku Mutu Udara Ambien Nasional **) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDNN = Satuan Volume Hisap Udara Kering dikoreksi pada Kondisi Normal (25°C, 76 cmHg)
Pengukuran Debu (TSP), PM10, PM2,5 dan Timbal (Pb) dilakukan sesaat sesuai permintaan pelanggan < = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 2 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-03/UA/06/2017 Uraian contoh : Udara Ambien U3. Well Pad Ml-09 (AQ-1B) Koordinat : S 01º 35’ 25,3” E 101º 07’ 41‚5” Metode pengambilan contoh : SNI 19-7119.6-2005 Tanggal diambil : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
Temperatur : 33 0C Arah Angin Dominan dari : Barat Kelembaban : 58 %RH Kecepatan Angin : 1,3 km/jam Cuaca : Cerah
Hasil Pengujian
NO PARAMETER WAKTU BAKU SATUAN HASIL METODE
PENGUKURAN
MUTU*)
1
Sulfur Dioksida (SO2) **) 1 Jam 900 Bg/Nm3 19
SNI 19-7119.7-2005 24 Jam 365 Bg/Nm3 - 2 Karbon Monoksida (CO) **) 1 Jam 30.000 Bg/Nm3
3.273 SNI 7119.10-2011 24 Jam 10.000 Bg/Nm3 -
3
Nitrogen Dioksida (NO2) **)
1 Jam 400 Bg/Nm3 18 SNI 19.7119.2.2005 24 Jam 150 Bg/Nm3 -
4 Oksidan (O3) **) 1 Jam 235 Bg/Nm3 39 SNI 19-7119.8-2005 5 Hidrokarbon (HC) **) 3 Jam 160 Bg/Nm3 100 SNI 7119.13-2009 6 Debu (TSP) 24 Jam 230 Bg/Nm3
- 18-2/IK/NA (Gravimetri) 1 Jam - Bg/Nm3 36
7
PM10 (Partikel < 10 Bm)
24 Jam 150 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 19
8
PM2,5 (Partikel < 2,5 Bm)
24 Jam 65 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 11
9 Timbal (Pb) 24 Jam 2 Bg/Nm3 - 18-3/IK/NA (AAS) 1 Jam - Bg/Nm3 <0,1
Keterangan : *) = PPRI No. 41 Tahun 1999 Baku Mutu Udara Ambien Nasional **) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDNN = Satuan Volume Hisap Udara Kering dikoreksi pada Kondisi Normal (25°C, 76 cmHg)
Pengukuran Debu (TSP), PM10, PM2,5 dan Timbal (Pb) dilakukan sesaat sesuai permintaan pelanggan < = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 3 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-04/UA/06/2017 Uraian contoh : Udara Ambien U4. Hunian Masyarakat - Jorong Taratak Tinggi (AQ 6) Koordinat : S 01º 35’ 45,55” E 101º 08’ 24‚30” Metode pengambilan contoh : SNI 19-7119.6-2005 Tanggal diambil : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
Temperatur : 32 - 33 0C Arah Angin Dominan dari : Barat Kelembaban : 58 - 62 %RH Kecepatan Angin : 1,5 km/jam Cuaca : Cerah
Hasil Pengujian
NO PARAMETER WAKTU BAKU SATUAN HASIL METODE
PENGUKURAN
MUTU*)
1
Sulfur Dioksida (SO2) **) 1 Jam 900 Bg/Nm3 17
SNI 19-7119.7-2005 24 Jam 365 Bg/Nm3 - 2 Karbon Monoksida (CO) **) 1 Jam 30.000 Bg/Nm3
3.116 SNI 7119.10-2011 24 Jam 10.000 Bg/Nm3 -
3
Nitrogen Dioksida (NO2) **)
1 Jam 400 Bg/Nm3 16 SNI 19.7119.2.2005 24 Jam 150 Bg/Nm3 -
4 Oksidan (O3) **) 1 Jam 235 Bg/Nm3 34 SNI 19-7119.8-2005 5 Hidrokarbon (HC) **) 3 Jam 160 Bg/Nm3 96 SNI 7119.13-2009 6 Debu (TSP) 24 Jam 230 Bg/Nm3
- 18-2/IK/NA (Gravimetri) 1 Jam - Bg/Nm3 31
7
PM10 (Partikel < 10 Bm)
24 Jam 150 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 17
8
PM2,5 (Partikel < 2,5 Bm)
24 Jam 65 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 9
9 Timbal (Pb) 24 Jam 2 Bg/Nm3 - 18-3/IK/NA (AAS) 1 Jam - Bg/Nm3 <0,1
Keterangan : *) = PPRI No. 41 Tahun 1999 Baku Mutu Udara Ambien Nasional **) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDNN = Satuan Volume Hisap Udara Kering dikoreksi pada Kondisi Normal (25°C, 76 cmHg)
Pengukuran Debu (TSP), PM10, PM2,5 dan Timbal (Pb) dilakukan sesaat sesuai permintaan pelanggan < = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 4 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-05/UA/06/2017 Uraian contoh : Udara Ambien U5. Hunian masyarakat - Jorong Sapan Sawi (AQ-7) Koordinat : S 01º 35’ 01,26” E 101º 08’ 33‚95” Metode pengambilan contoh : SNI 19-7119.6-2005 Tanggal diambil : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
Temperatur : 34 0C Arah Angin Dominan dari : Barat Kelembaban : 56 %RH Kecepatan Angin : 1,5 km/jam Cuaca : Cerah
Hasil Pengujian
NO PARAMETER WAKTU BAKU SATUAN HASIL METODE
PENGUKURAN
MUTU*)
1
Sulfur Dioksida (SO2) **) 1 Jam 900 Bg/Nm3 16
SNI 19-7119.7-2005 24 Jam 365 Bg/Nm3 - 2 Karbon Monoksida (CO) **) 1 Jam 30.000 Bg/Nm3
3.001 SNI 7119.10-2011 24 Jam 10.000 Bg/Nm3 -
3
Nitrogen Dioksida (NO2) **)
1 Jam 400 Bg/Nm3 15 SNI 19.7119.2.2005 24 Jam 150 Bg/Nm3 -
4 Oksidan (O3) **) 1 Jam 235 Bg/Nm3 28 SNI 19-7119.8-2005 5 Hidrokarbon (HC) **) 3 Jam 160 Bg/Nm3 94 SNI 7119.13-2009 6 Debu (TSP) 24 Jam 230 Bg/Nm3
- 18-2/IK/NA (Gravimetri) 1 Jam - Bg/Nm3 40
7
PM10 (Partikel < 10 Bm)
24 Jam 150 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 21
8
PM2,5 (Partikel < 2,5 Bm)
24 Jam 65 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 12
9 Timbal (Pb) 24 Jam 2 Bg/Nm3 - 18-3/IK/NA (AAS) 1 Jam - Bg/Nm3 <0,1
Keterangan : *) = PPRI No. 41 Tahun 1999 Baku Mutu Udara Ambien Nasional **) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDNN = Satuan Volume Hisap Udara Kering dikoreksi pada Kondisi Normal (25°C, 76 cmHg)
Pengukuran Debu (TSP), PM10, PM2,5 dan Timbal (Pb) dilakukan sesaat sesuai permintaan pelanggan < = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 5 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-06/UA/06/2017 Uraian contoh : Udara Ambien U6. Wellpad H Area (AQ-1) Koordinat : S 01º 38’ 01,64” E 101º 07’ 50‚29” Metode pengambilan contoh : SNI 19-7119.6-2005 Tanggal diambil : 09 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
Temperatur : 32 - 33 0C Arah Angin Dominan dari : Timur Kelembaban : 58 - 62 %RH Kecepatan Angin : 1,5 km/jam Cuaca : Cerah
Hasil Pengujian
NO PARAMETER WAKTU BAKU SATUAN HASIL METODE
PENGUKURAN
MUTU*)
1
Sulfur Dioksida (SO2) **) 1 Jam 900 Bg/Nm3 15
SNI 19-7119.7-2005 24 Jam 365 Bg/Nm3 - 2 Karbon Monoksida (CO) **) 1 Jam 30.000 Bg/Nm3
2.822 SNI 7119.10-2011 24 Jam 10.000 Bg/Nm3 -
3
Nitrogen Dioksida (NO2) **)
1 Jam 400 Bg/Nm3 13 SNI 19.7119.2.2005 24 Jam 150 Bg/Nm3 -
4 Oksidan (O3) **) 1 Jam 235 Bg/Nm3 29 SNI 19-7119.8-2005 5 Hidrokarbon (HC) **) 3 Jam 160 Bg/Nm3 89 SNI 7119.13-2009 6 Debu (TSP) 24 Jam 230 Bg/Nm3
- 18-2/IK/NA (Gravimetri) 1 Jam - Bg/Nm3 25
7
PM10 (Partikel < 10 Bm)
24 Jam 150 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 14
8
PM2,5 (Partikel < 2,5 Bm)
24 Jam 65 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 8
9 Timbal (Pb) 24 Jam 2 Bg/Nm3 - 18-3/IK/NA (AAS) 1 Jam - Bg/Nm3 <0,1
Keterangan : *) = PPRI No. 41 Tahun 1999 Baku Mutu Udara Ambien Nasional **) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDNN = Satuan Volume Hisap Udara Kering dikoreksi pada Kondisi Normal (25°C, 76 cmHg)
Pengukuran Debu (TSP), PM10, PM2,5 dan Timbal (Pb) dilakukan sesaat sesuai permintaan pelanggan < = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 6 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-07/UA/06/2017 Uraian contoh : Udara Ambien U7. Wellpad A Area (AQ-3) Koordinat : S 01º 37’ 44,93” E 101º 07’ 56‚51” Metode pengambilan contoh : SNI 19-7119.6-2005 Tanggal diambil : 09 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
Temperatur : 31 0C Arah Angin Dominan dari : Barat Kelembaban : 64 %RH Kecepatan Angin : 1,5 km/jam Cuaca : Cerah
Hasil Pengujian
NO PARAMETER WAKTU BAKU SATUAN HASIL METODE
PENGUKURAN
MUTU*)
1
Sulfur Dioksida (SO2) **) 1 Jam 900 Bg/Nm3 24
SNI 19-7119.7-2005 24 Jam 365 Bg/Nm3 - 2 Karbon Monoksida (CO) **) 1 Jam 30.000 Bg/Nm3
3.563 SNI 7119.10-2011 24 Jam 10.000 Bg/Nm3 -
3
Nitrogen Dioksida (NO2) **)
1 Jam 400 Bg/Nm3 23 SNI 19.7119.2.2005 24 Jam 150 Bg/Nm3 -
4 Oksidan (O3) **) 1 Jam 235 Bg/Nm3 33 SNI 19-7119.8-2005 5 Hidrokarbon (HC) **) 3 Jam 160 Bg/Nm3 116 SNI 7119.13-2009 6 Debu (TSP) 24 Jam 230 Bg/Nm3
- 18-2/IK/NA (Gravimetri) 1 Jam - Bg/Nm3 48
7
PM10 (Partikel < 10 Bm)
24 Jam 150 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 25
8
PM2,5 (Partikel < 2,5 Bm)
24 Jam 65 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 14
9 Timbal (Pb) 24 Jam 2 Bg/Nm3 - 18-3/IK/NA (AAS) 1 Jam - Bg/Nm3 <0,1
Keterangan : *) = PPRI No. 41 Tahun 1999 Baku Mutu Udara Ambien Nasional **) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDNN = Satuan Volume Hisap Udara Kering dikoreksi pada Kondisi Normal (25°C, 76 cmHg)
Pengukuran Debu (TSP), PM10, PM2,5 dan Timbal (Pb) dilakukan sesaat sesuai permintaan pelanggan < = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 7 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-08/UA/06/2017 Uraian contoh : Udara Ambien U8. Power Station Area (AQ-5) Koordinat : S 01º 36’ 21,53” E 101º 08’ 56‚01” Metode pengambilan contoh : SNI 19-7119.6-2005 Tanggal diambil : 09 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
Temperatur : 32 0C Arah Angin Dominan dari : Barat Kelembaban : 62 %RH Kecepatan Angin : 1,5 km/jam Cuaca : Cerah
Hasil Pengujian
NO PARAMETER WAKTU BAKU SATUAN HASIL METODE
PENGUKURAN
MUTU*)
1
Sulfur Dioksida (SO2) **) 1 Jam 900 Bg/Nm3 23
SNI 19-7119.7-2005 24 Jam 365 Bg/Nm3 - 2 Karbon Monoksida (CO) **) 1 Jam 30.000 Bg/Nm3
3.506 SNI 7119.10-2011 24 Jam 10.000 Bg/Nm3 -
3
Nitrogen Dioksida (NO2) **)
1 Jam 400 Bg/Nm3 22 SNI 19.7119.2.2005 24 Jam 150 Bg/Nm3 -
4 Oksidan (O3) **) 1 Jam 235 Bg/Nm3 35 SNI 19-7119.8-2005 5 Hidrokarbon (HC) **) 3 Jam 160 Bg/Nm3 113 SNI 7119.13-2009 6 Debu (TSP) 24 Jam 230 Bg/Nm3
- 18-2/IK/NA (Gravimetri) 1 Jam - Bg/Nm3 57
7
PM10 (Partikel < 10 Bm)
24 Jam 150 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 67
8
PM2,5 (Partikel < 2,5 Bm)
24 Jam 65 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 18
9 Timbal (Pb) 24 Jam 2 Bg/Nm3 - 18-3/IK/NA (AAS) 1 Jam - Bg/Nm3 <0,1
Keterangan : *) = PPRI No. 41 Tahun 1999 Baku Mutu Udara Ambien Nasional **) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDNN = Satuan Volume Hisap Udara Kering dikoreksi pada Kondisi Normal (25°C, 76 cmHg)
Pengukuran Debu (TSP), PM10, PM2,5 dan Timbal (Pb) dilakukan sesaat sesuai permintaan pelanggan < = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 8 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-09/UA/06/2017 Uraian contoh : Udara Ambien U9. Wellpad ML-F (AQ-3B) Koordinat : S 01º 37’ 37,01” E 101º 07’ 52‚06” Metode pengambilan contoh : SNI 19-7119.6-2005 Tanggal diambil : 09 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
Temperatur : 34 0C Arah Angin Dominan dari : Barat Kelembaban : 56 %RH Kecepatan Angin : 1,6 km/jam Cuaca : Cerah
Hasil Pengujian
NO PARAMETER WAKTU BAKU SATUAN HASIL METODE
PENGUKURAN
MUTU*)
1
Sulfur Dioksida (SO2) **) 1 Jam 900 Bg/Nm3 21
SNI 19-7119.7-2005 24 Jam 365 Bg/Nm3 - 2 Karbon Monoksida (CO) **) 1 Jam 30.000 Bg/Nm3
3.475 SNI 7119.10-2011 24 Jam 10.000 Bg/Nm3 -
3
Nitrogen Dioksida (NO2) **)
1 Jam 400 Bg/Nm3 20 SNI 19.7119.2.2005 24 Jam 150 Bg/Nm3 -
4 Oksidan (O3) **) 1 Jam 235 Bg/Nm3 40 SNI 19-7119.8-2005 5 Hidrokarbon (HC) **) 3 Jam 160 Bg/Nm3 113 SNI 7119.13-2009 6 Debu (TSP) 24 Jam 230 Bg/Nm3
- 18-2/IK/NA (Gravimetri) 1 Jam - Bg/Nm3 53
7
PM10 (Partikel < 10 Bm)
24 Jam 150 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 28
8
PM2,5 (Partikel < 2,5 Bm)
24 Jam 65 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 15
9 Timbal (Pb) 24 Jam 2 Bg/Nm3 - 18-3/IK/NA (AAS) 1 Jam - Bg/Nm3 <0,1
Keterangan : *) = PPRI No. 41 Tahun 1999 Baku Mutu Udara Ambien Nasional **) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDNN = Satuan Volume Hisap Udara Kering dikoreksi pada Kondisi Normal (25°C, 76 cmHg)
Pengukuran Debu (TSP), PM10, PM2,5 dan Timbal (Pb) dilakukan sesaat sesuai permintaan pelanggan < = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 9 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-10/UA/06/2017 Uraian contoh : Udara Ambien U10. Wellpad B Area (AQ-2) Koordinat : S 01º 37’ 45,34” E 101º 08’ 16‚34” Metode pengambilan contoh : SNI 19-7119.6-2005 Tanggal diambil : 10 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
Temperatur : 31 0C Arah Angin Dominan dari : Barat Kelembaban : 64 %RH Kecepatan Angin : 1,5 km/jam Cuaca : Berawan
Hasil Pengujian
NO PARAMETER WAKTU BAKU SATUAN HASIL METODE
PENGUKURAN
MUTU*)
1
Sulfur Dioksida (SO2) **) 1 Jam 900 Bg/Nm3 18
SNI 19-7119.7-2005 24 Jam 365 Bg/Nm3 - 2 Karbon Monoksida (CO) **) 1 Jam 30.000 Bg/Nm3
2.875 SNI 7119.10-2011 24 Jam 10.000 Bg/Nm3 -
3
Nitrogen Dioksida (NO2) **)
1 Jam 400 Bg/Nm3 17 SNI 19.7119.2.2005 24 Jam 150 Bg/Nm3 -
4 Oksidan (O3) **) 1 Jam 235 Bg/Nm3 25 SNI 19-7119.8-2005 5 Hidrokarbon (HC) **) 3 Jam 160 Bg/Nm3 96 SNI 7119.13-2009 6 Debu (TSP) 24 Jam 230 Bg/Nm3
- 18-2/IK/NA (Gravimetri) 1 Jam - Bg/Nm3 23
7
PM10 (Partikel < 10 Bm)
24 Jam 150 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 13
8
PM2,5 (Partikel < 2,5 Bm)
24 Jam 65 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 7
9 Timbal (Pb) 24 Jam 2 Bg/Nm3 - 18-3/IK/NA (AAS) 1 Jam - Bg/Nm3 <0,1
Keterangan : *) = PPRI No. 41 Tahun 1999 Baku Mutu Udara Ambien Nasional **) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDNN = Satuan Volume Hisap Udara Kering dikoreksi pada Kondisi Normal (25°C, 76 cmHg)
Pengukuran Debu (TSP), PM10, PM2,5 dan Timbal (Pb) dilakukan sesaat sesuai permintaan pelanggan < = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 10 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-11/UA/06/2017 Uraian contoh : Udara Ambien U11. East of Wellpad 6 Area (AQ-4) Koordinat : S 01º 37’ 56,19” E 101º 08’ 27‚38” Metode pengambilan contoh : SNI 19-7119.6-2005 Tanggal diambil : 11 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
Temperatur : 29 - 30 0C Arah Angin Dominan dari : Barat Kelembaban : 67 - 69 %RH Kecepatan Angin : 2,3 km/jam Cuaca : Berawan
Hasil Pengujian
NO PARAMETER WAKTU BAKU SATUAN HASIL METODE
PENGUKURAN
MUTU*)
1
Sulfur Dioksida (SO2) **) 1 Jam 900 Bg/Nm3 14
SNI 19-7119.7-2005 24 Jam 365 Bg/Nm3 - 2 Karbon Monoksida (CO) **) 1 Jam 30.000 Bg/Nm3 2.761 SNI 7119.10-2011 24 Jam 10.000 Bg/Nm3 -
3
Nitrogen Dioksida (NO2) **)
1 Jam 400 Bg/Nm3 12 SNI 19.7119.2.2005 24 Jam 150 Bg/Nm3 -
4 Oksidan (O3) **) 1 Jam 235 Bg/Nm3 17 SNI 19-7119.8-2005 5 Hidrokarbon (HC) **) 3 Jam 160 Bg/Nm3 89 SNI 7119.13-2009 6 Debu (TSP) 24 Jam 230 Bg/Nm3 - 18-2/IK/NA (Gravimetri) 1 Jam - Bg/Nm3 16
7
PM10 (Partikel < 10 Bm)
24 Jam 150 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 9
8
PM2,5 (Partikel < 2,5 Bm)
24 Jam 65 Bg/Nm3 - LVAS - Gravimetri 1 Jam - Bg/Nm3 6
9 Timbal (Pb) 24 Jam 2 Bg/Nm3 - 18-3/IK/NA (AAS) 1 Jam - Bg/Nm3 <0,1
Keterangan : *) = PPRI No. 41 Tahun 1999 Baku Mutu Udara Ambien Nasional **) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDNN = Satuan Volume Hisap Udara Kering dikoreksi pada Kondisi Normal (25°C, 76 cmHg)
Pengukuran Debu (TSP), PM10, PM2,5 dan Timbal (Pb) dilakukan sesaat sesuai permintaan pelanggan < = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 11 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-12/KB/06/2017 Uraian contoh : Kebauan (Camp Site Office / AQ-4B) Koordinat : S 01º 36’ 35,6” E 101º 8’ 44‚6” Metode pengambilan contoh : SNI 19-7119.6-2005 Tanggal pengambilan : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
0C
Temperatur : 28 - 29 Arah Angin Dominan dari : Timur Kelembaban : 69 - 75 %RH Kecepatan Angin : 1,0 Km/jam Cuaca : Cerah
Hasil Pengujian
NO
PARAMETER
SATUAN
BAKU *) HASIL
METODE
MUTU
1 Amonia (NH3) **) ppm 2,0 0,04 SNI 19-7119.1-2005
2 Hidrogen Sulfida (H2S) **)
ppm
0,02
<0,003 Mth of air sampling&analysis 3rd
Ed. 2.70-1988
3 Styrene (C6H5CHCH2) **) ppm 0,1 <0,02 NIOSH Ed. 4th 1501 1994
4 Metil Merkaptan (CH3SH) ppm 0,002 <0,0017 NIOSH Ed. 4th 2542 1994
5 Metil Sulfida (CH3)2S ppm 0,01 <0,0008 NIOSH Ed. 4th 2542 1994
Keterangan : *) = KEP 50/MENLH/XI/1996 Baku Tingkat Kebauan **) = Parameter terakreditasi oleh KAN No. LP-195-IDN • Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDN
< = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 12 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-13/KB/06/2017 Uraian contoh : Kebauan (Area PLPT / AQ-2B) Koordinat : S 01º 37’ 40,1” E 101º 07’ 52‚6” Metode pengambilan contoh : SNI 7231 : 2009 Tanggal pengambilan : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
0C
Temperatur : 31 Arah Angin Dominan dari : Timur Kelembaban : 64 %RH Kecepatan Angin : 1,3 Km/jam Cuaca : Cerah
Hasil Pengujian
NO
PARAMETER
SATUAN
BAKU *) HASIL
METODE
MUTU
1 Amonia (NH3) **) ppm 2,0 0,02 SNI 19-7119.1-2005
2 Hidrogen Sulfida (H2S) **)
ppm
0,02
<0,003 Mth of air sampling&analysis 3rd
Ed. 2.70-1988
3 Styrene (C6H5CHCH2) **) ppm 0,1 <0,02 NIOSH Ed. 4th 1501 1994
4 Metil Merkaptan (CH3SH) ppm 0,002 <0,0017 NIOSH Ed. 4th 2542 1994
5 Metil Sulfida (CH3)2S ppm 0,01 <0,0008 NIOSH Ed. 4th 2542 1994
Keterangan : *) = KEP 50/MENLH/XI/1996 Baku Tingkat Kebauan **) = Parameter terakreditasi oleh KAN No. LP-195-IDN • Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDN
< = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 13 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-14/KB/06/2017 Uraian contoh : Kebauan (Well Pad Ml-09 / AQ-1B) Koordinat : S 01º 35’ 25,3” E 101º 07’ 41‚5” Metode pengambilan contoh : SNI 19-7119.6-2005 Tanggal pengambilan : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
0C
Temperatur : 33 Arah Angin Dominan dari : Barat Kelembaban : 58 %RH Kecepatan Angin : 1,3 Km/jam Cuaca : Cerah
Hasil Pengujian
NO
PARAMETER
SATUAN
BAKU *) HASIL
METODE
MUTU
1 Amonia (NH3) **) ppm 2,0 0,02 SNI 19-7119.1-2005
2 Hidrogen Sulfida (H2S) **)
ppm
0,02
<0,003
Mth of air sampling&analysis 3rd Ed. 2.70-1988
3 Styrene (C6H5CHCH2) **) ppm 0,1 <0,02 NIOSH Ed. 4th 1501 1994
4 Metil Merkaptan (CH3SH) ppm 0,002 <0,0017 NIOSH Ed. 4th 2542 1994
5 Metil Sulfida (CH3)2S ppm 0,01 <0,0008 NIOSH Ed. 4th 2542 1994
Keterangan : *) = KEP 50/MENLH/XI/1996 Baku Tingkat Kebauan **) = Parameter terakreditasi oleh KAN No. LP-195-IDN • Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDN
< = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 14 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-15/KB/06/2017 Uraian contoh : Kebauan (Hunian Masyarakat - Jorong Taratak Tinggi / AQ 6) Koordinat : S 01º 35’ 45,55” E 101º 08’ 24‚30” Metode pengambilan contoh : SNI 19-7119.6-2005 Tanggal pengambilan : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
0C
Temperatur : 32 - 33 Arah Angin Dominan dari : Barat Kelembaban : 58 - 63 %RH Kecepatan Angin : 1,5 Km/jam Cuaca : Cerah
Hasil Pengujian
NO
PARAMETER
SATUAN
BAKU *) HASIL
METODE
MUTU
1 Amonia (NH3) **) ppm 2,0 0,04 SNI 19-7119.1-2005
2 Hidrogen Sulfida (H2S) **)
ppm
0,02
<0,003
Mth of air sampling&analysis 3rd Ed. 2.70-1988
3 Styrene (C6H5CHCH2) **) ppm 0,1 <0,02 NIOSH Ed. 4th 1501 1994
4 Metil Merkaptan (CH3SH) ppm 0,002 <0,0017 NIOSH Ed. 4th 2542 1994
5 Metil Sulfida (CH3)2S ppm 0,01 <0,0008 NIOSH Ed. 4th 2542 1994
Keterangan : *) = KEP 50/MENLH/XI/1996 Baku Tingkat Kebauan **) = Parameter terakreditasi oleh KAN No. LP-195-IDN • Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDN
< = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 15 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-16/KB/06/2017 Uraian contoh : Kebauan (Hunian masyarakat - Jorong Sapan Sawi / AQ-7) Koordinat : S 01º 35’ 01,26” E 101º 08’ 33‚95” Metode pengambilan contoh : SNI 19-7119.6-2005 Tanggal pengambilan : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
0C
Temperatur : 34 Arah Angin Dominan dari : Barat Kelembaban : 56 %RH Kecepatan Angin : 1,5 Km/jam Cuaca : Cerah
Hasil Pengujian
NO
PARAMETER
SATUAN
BAKU *) HASIL
METODE
MUTU
1 Amonia (NH3) **) ppm 2,0 0,04 SNI 19-7119.1-2005
2 Hidrogen Sulfida (H2S) **)
ppm
0,02
<0,003 Mth of air sampling&analysis 3rd
Ed. 2.70-1988
3 Styrene (C6H5CHCH2) **) ppm 0,1 <0,02 NIOSH Ed. 4th 1501 1994
4 Metil Merkaptan (CH3SH) ppm 0,002 <0,0017 NIOSH Ed. 4th 2542 1994
5 Metil Sulfida (CH3)2S ppm 0,01 <0,0008 NIOSH Ed. 4th 2542 1994
Keterangan : *) = KEP 50/MENLH/XI/1996 Baku Tingkat Kebauan **) = Parameter terakreditasi oleh KAN No. LP-195-IDN • Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDN
< = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 16 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-17/KB/06/2017 Uraian contoh : Kebauan (Wellpad H Area / AQ-1) Koordinat : S 01º 38’ 01,64” E 101º 07’ 50‚29” Metode pengambilan contoh : SNI 19-7119.6-2005 Tanggal pengambilan : 09 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
0C
Temperatur : 32 - 33 Arah Angin Dominan dari : Timur Kelembaban : 58 - 62 %RH Kecepatan Angin : 1,5 Km/jam Cuaca : Cerah
Hasil Pengujian
NO
PARAMETER
SATUAN
BAKU *) HASIL
METODE
MUTU
1 Amonia (NH3) **) ppm 2,0 0,02 SNI 19-7119.1-2005
2 Hidrogen Sulfida (H2S) **)
ppm
0,02
<0,003
Mth of air sampling&analysis 3rd Ed. 2.70-1988
3 Styrene (C6H5CHCH2) **) ppm 0,1 <0,02 NIOSH Ed. 4th 1501 1994
4 Metil Merkaptan (CH3SH) ppm 0,002 <0,0017 NIOSH Ed. 4th 2542 1994
5 Metil Sulfida (CH3)2S ppm 0,01 <0,0008 NIOSH Ed. 4th 2542 1994
Keterangan : *) = KEP 50/MENLH/XI/1996 Baku Tingkat Kebauan **) = Parameter terakreditasi oleh KAN No. LP-195-IDN • Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDN
< = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 17 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-18/KB/06/2017 Uraian contoh : Kebauan (Wellpad A Area / AQ-3) Koordinat : S 01º 37’ 44,93” E 101º 07’ 56‚51” Metode pengambilan contoh : SNI 19-7119.6-2005 Tanggal pengambilan : 09 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
0C
Temperatur : 31 Arah Angin Dominan dari : Barat Kelembaban : 64 %RH Kecepatan Angin : 1,5 Km/jam Cuaca : Cerah
Hasil Pengujian
NO
PARAMETER
SATUAN
BAKU *) HASIL
METODE
MUTU
1 Amonia (NH3) **) ppm 2,0 0,02 SNI 19-7119.1-2005
2 Hidrogen Sulfida (H2S) **)
ppm
0,02
<0,003
Mth of air sampling&analysis 3rd Ed. 2.70-1988
3 Styrene (C6H5CHCH2) **) ppm 0,1 <0,02 NIOSH Ed. 4th 1501 1994
4 Metil Merkaptan (CH3SH) ppm 0,002 <0,0017 NIOSH Ed. 4th 2542 1994
5 Metil Sulfida (CH3)2S ppm 0,01 <0,0008 NIOSH Ed. 4th 2542 1994
Keterangan : *) = KEP 50/MENLH/XI/1996 Baku Tingkat Kebauan **) = Parameter terakreditasi oleh KAN No. LP-195-IDN • Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDN
< = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 18 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-19/KB/06/2017 Uraian contoh : Kebauan (Power Station Area / AQ-5) Koordinat : S 01º 36’ 21,53” E 101º 08’ 56‚01” Metode pengambilan contoh : SNI 19-7119.6-2005 Tanggal pengambilan : 09 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
0C
Temperatur : 32 Arah Angin Dominan dari : Barat Kelembaban : 62 %RH Kecepatan Angin : 1,5 Km/jam Cuaca : Cerah
Hasil Pengujian
NO
PARAMETER
SATUAN
BAKU *) HASIL
METODE
MUTU
1 Amonia (NH3) **) ppm 2,0 0,04 SNI 19-7119.1-2005
2 Hidrogen Sulfida (H2S) **)
ppm
0,02
<0,003 Mth of air sampling&analysis 3rd
Ed. 2.70-1988
3 Styrene (C6H5CHCH2) **) ppm 0,1 <0,02 NIOSH Ed. 4th 1501 1994
4 Metil Merkaptan (CH3SH) ppm 0,002 <0,0017 NIOSH Ed. 4th 2542 1994
5 Metil Sulfida (CH3)2S ppm 0,01 <0,0008 NIOSH Ed. 4th 2542 1994
Keterangan : *) = KEP 50/MENLH/XI/1996 Baku Tingkat Kebauan **) = Parameter terakreditasi oleh KAN No. LP-195-IDN • Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDN
< = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 19 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-20/KB/06/2017 Uraian contoh : Kebauan (Wellpad ML-F / AQ-3B) Koordinat : S 01º 37’ 37,01” E 101º 07’ 52‚06” Metode pengambilan contoh : SNI 19-7119.6-2005 Tanggal pengambilan : 09 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
0C
Temperatur : 34 Arah Angin Dominan dari : Barat Kelembaban : 56 %RH Kecepatan Angin : 1,6 Km/jam Cuaca : Cerah
Hasil Pengujian
NO
PARAMETER
SATUAN
BAKU *) HASIL
METODE
MUTU
1 Amonia (NH3) **) ppm 2,0 0,02 SNI 19-7119.1-2005
2 Hidrogen Sulfida (H2S) **)
ppm
0,02
<0,003
Mth of air sampling&analysis 3rd Ed. 2.70-1988
3 Styrene (C6H5CHCH2) **) ppm 0,1 <0,02 NIOSH Ed. 4th 1501 1994
4 Metil Merkaptan (CH3SH) ppm 0,002 <0,0017 NIOSH Ed. 4th 2542 1994
5 Metil Sulfida (CH3)2S ppm 0,01 <0,0008 NIOSH Ed. 4th 2542 1994
Keterangan : *) = KEP 50/MENLH/XI/1996 Baku Tingkat Kebauan **) = Parameter terakreditasi oleh KAN No. LP-195-IDN • Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDN
< = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 20 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-21/KB/06/2017 Uraian contoh : Kebauan (Wellpad B Area / AQ-2) Koordinat : S 01º 37’ 45,34” E 101º 08’ 16‚34” Metode pengambilan contoh : SNI 19-7119.6-2005 Tanggal pengambilan : 10 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
0C
Temperatur : 31 Arah Angin Dominan dari : Barat Kelembaban : 64 %RH Kecepatan Angin : 1,5 Km/jam Cuaca : Cerah
Hasil Pengujian
NO
PARAMETER
SATUAN
BAKU *) HASIL
METODE
MUTU
1 Amonia (NH3) **) ppm 2,0 0,02 SNI 19-7119.1-2005
2 Hidrogen Sulfida (H2S) **)
ppm
0,02
<0,003 Mth of air sampling&analysis 3rd
Ed. 2.70-1988
3 Styrene (C6H5CHCH2) **) ppm 0,1 <0,02 NIOSH Ed. 4th 1501 1994
4 Metil Merkaptan (CH3SH) ppm 0,002 <0,0017 NIOSH Ed. 4th 2542 1994
5 Metil Sulfida (CH3)2S ppm 0,01 <0,0008 NIOSH Ed. 4th 2542 1994
Keterangan : *) = KEP 50/MENLH/XI/1996 Baku Tingkat Kebauan **) = Parameter terakreditasi oleh KAN No. LP-195-IDN • Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDN
< = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 21 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-22/KB/06/2017 Uraian contoh : Kebauan (East of Wellpad 6 Area / AQ-4) Koordinat : S 01º 37’ 56,19” E 101º 08’ 27‚38” Metode pengambilan contoh : SNI 19-7119.6-2005 Tanggal pengambilan : 11 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengukuran Lapangan
0C
Temperatur : 29 - 30 Arah Angin Dominan dari : Barat Kelembaban : 29 - 30 %RH Kecepatan Angin : 2,3 Km/jam Cuaca : Cerah
Hasil Pengujian
NO
PARAMETER
SATUAN
BAKU *) HASIL
METODE
MUTU
1 Amonia (NH3) **) ppm 2,0 0,04 SNI 19-7119.1-2005
2 Hidrogen Sulfida (H2S) **)
ppm
0,02
<0,003
Mth of air sampling&analysis 3rd Ed. 2.70-1988
3 Styrene (C6H5CHCH2) **) ppm 0,1 <0,02 NIOSH Ed. 4th 1501 1994
4 Metil Merkaptan (CH3SH) ppm 0,002 <0,0017 NIOSH Ed. 4th 2542 1994
5 Metil Sulfida (CH3)2S ppm 0,01 <0,0008 NIOSH Ed. 4th 2542 1994
Keterangan : *) = KEP 50/MENLH/XI/1996 Baku Tingkat Kebauan **) = Parameter terakreditasi oleh KAN No. LP-195-IDN • Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDN
< = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 22 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-23/K/06/2017 Uraian contoh : Kebisingan Halaman Luar **) Metode pengambilan contoh : SNI 7231 : 2009 Tanggal diambil : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
NO. LOKASI SUMBER KEBISINGAN HASIL *) dB(A)
1 Camp Site Office (AQ- B) Aktivitas keluar masuknya 48 S 01º 36’ 35,6” E 101º 8’ 44‚6” kendaraan tamu
2 Area PLPT (AQ-2B) Aktivitas kendaraan tamu
dan 47 S 01º 37’ 40,1” E 101º 07’ 52‚6" pabrik
3 Well Pad Ml-09 (AQ-1B) Aktivitas kendaraan warga 41 S 01º 35’ 25,3” E 101º 07’ 41‚5”
4 Hunian Masyarakat - Jorong Taratak Tinggi (AQ 6) Aktivitas kendaraan warga 41 S 01º 35’ 45,55” E 101º 08’ 24‚30”
5 Hunian masyarakat - Jorong Sapan Sawi (AQ-7) Aktivitas jalan raya dan warga 52 S 01º 35’ 01,26” E 101º 08’ 33‚95”
6 Wellpad H Area (AQ-1) Aktivitas hutan 42 S 01º 38’ 01,64” E 101º 07’ 50‚29”
7 Wellpad A Area (AQ-3) Tidak ada aktivitas 42 S 01º 37’ 44,93” E 101º 07’ 56‚51”
8 Power Station Area (AQ-5) Tidak ada aktivitas 50 S 01º 36’ 21,53” E 101º 08’ 56‚01”
9 Wellpad ML-F (AQ-3B) Tidak ada aktivitas 42 S 01º 37’ 37,01” E 101º 07’ 52‚06”
10 Wellpad B Area (AQ-2) Tidak ada aktivitas 41 S 01º 37’ 45,34” E 101º 08’ 16‚34”
11 East of Wellpad 6 Area (AQ-4) Tidak ada aktivitas 52 S 01º 37’ 56,19” E 101º 08’ 27‚38”
METODE 22-3/IK/UA-O (Sound Level Meter)
Keterangan : *) = Nilai kebisingan adalah Nilai Equivalen selama waktu pengukuran dilakukan sesaat selama 10 menit dengan interval 5 detik. **) = Parameter terakreditasi oleh KAN No. LP-195-IDN
• KEP. 48/MENLH/11/1996, Nilai Ambang Batas Kebisingan 24 Jam : A. Peruntukan Kawasan B. Lingkungan Kegiatan 1. Pemerintahan dan Fasilitas Umum = 60 dB(A) 1. Tempat Ibadah atau sejenisnya = 55 dB(A) 2. Perkantoran dan Perdagangan = 65 dB(A) 2. Rumah Sakit dan sejenisnya = 55 dB(A)
3. Perumahan dan Pemukiman = 55 dB(A) 3. Sekolah atau sejenisnya = 55 dB(A) 4. Perdagangan dan Jasa = 70 dB(A) 5. Ruang terbuka Hijau = 50 dB(A) 6. Rekreasi = 70 dB(A) 7. Industri = 70 dB(A) 8. Khusus
- Stasiun Kereta Api = 70 dB(A) - Pelabuhan Laut = 70 dB(A) - Bandar Udara = 70 dB(A) - Cagar Budaya = 60 dB(A)
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 23 dari 51 • Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-24/AM/06/2017 Uraian contoh : Air Minum (Sumur Gali Masyarakat Jorong Taratak Tinggi) (GW-1) Koordinat : LS 01º 35’ 44‚76” BT 101º 08’ 27‚34" Metode pengambilan contoh : SNI-06-2412-1991 Tanggal pengambilan : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
NO PARAMETER SATUAN KADAR *) HASIL METODE
MAKSIMUM
I PARAMETER WAJIB 1 Parameter yang berhubungan langsung dengan kesehatan
a.Parameter Mikrobiologi 1) E. Coli **) Jml/100 ml 0 0 SNI ISO 9308-1:2010 2) Total Bakteri Koliform **) Jml/100 ml 0 0 SNI ISO 9308-1:2010 b. Kimia an-organik 1) Arsen mg/L 0,01 <0,005 APHA Ed. 22nd 3114.B - 2012 2) Fluorida (F) **) mg/L 1,5 0,02 APHA Ed. 22nd 4500-F.D-2012 3) Total Kromium (Cr) **) mg/L 0,05 <0,003 APHA Ed. 22nd 3120.B, 3030 B-2012 4) Kadmium (Cd) **) mg/L 0,003 <0,002 APHA Ed. 22nd 3120.B, 3030 B-2012 5) Nitrit (sebagai NO2) **) mg/L 3 <0,002 18-36/IK/A (test kit) 6) Nitrat, (sebagai NO3) **) mg/L 50 4 18-30/IK/A (test kit) 7) Sianida (CN) **) mg/L 0,07 <0,005 APHA Ed. 22nd 4500-CN.E-2012 8) Selenium (Se) mg/L 0,01 <0,002 APHA Ed. 22nd 3114.B - 2012
2 Parameter yang tidak langsung berhubungan dengan kesehatan a. Parameter Fisik
1) Bau (insitu) **) - Tdk.berbau Tdk
berbau SNI 06-6860-2002 2) Warna **) TCU 15 2 18-11/IK/A (Spektrofotometri) 3) Total zat padat terlarut (TDS) **) mg/L 500 56 18-6/IK/A (Konduktometri) 4) Kekeruhan **) NTU 5 11 SNI 06-6989.25-2005 5) Rasa **) - Tdk.berasa Tdk berasa SNI 06-6859-2002 6) Suhu (insitu) **) oC Suhu udara + 3 23 SNI 06-6989.23-2005
b. Parameter kimiawi 1) Aluminium (Al) **) mg/L 0,2 <0,004 APHA Ed. 22nd 3120.B, 3030 B-2012 2) Besi (Fe) **) mg/L 0,3 0,05 APHA Ed. 22nd 3120.B, 3030 B-2012 3) Kesadahan **) mg/L 500 29 SNI 06-6989.12-2004 4) Khlorida (Cl) **) mg/L 250 6 SNI 06-6989.19-2009 5) Mangan (Mn) **) mg/L 0,4 0,1 APHA Ed. 22nd 3120.B, 3030 B-2012 6) pH (insitu) **) - 6,5-8,5 7 SNI 06-6989.11-2004 7) Seng (Zn) **) mg/L 3 <0,008 APHA Ed. 22nd 3120.B, 3030 B-2012 8) Sulfat **) mg/L 250 4 SNI 06-6989.20-2009 9) Tembaga (Cu) **) mg/L 2 <0,009 APHA Ed. 22nd 3120.B, 3030 B-2012 10) Amonia **) mg/L 1,5 0,02 SNI 06-6989.30-2005 II PARAMETER TAMBAHAN KIMIAWI a. Bahan Anorganik 1) Air Raksa (Hg) mg/L 0,001 <0,0005 APHA Ed. 22nd 3112.B - 2012 2) Antimon (Sb) mg/L 0,02 <0,002 APHA Ed. 22nd 3120.B, 3030 B-2012 3) Barium (Ba) **) mg/L 0,7 <0,004 APHA Ed. 22nd 3120.B, 3030 B-2012 4) Boron (B) **) mg/L 0,5 <0,02 APHA Ed. 22nd 3120.B, 3030 B-2012 5) Molybdenum (Mo) mg/L 0,07 <0,02 APHA Ed. 22nd 3120.B, 3030 B-2012 6) Nikel (Ni) **) mg/L 0,07 <0,004 APHA Ed. 22nd 3120.B, 3030 B-2012 7) Sodium (Na) **) mg/L 200 3 APHA Ed. 22nd 3120 B, 3030 B-2012 8) Timbal (Pb) **) mg/L 0,01 <0,004 APHA Ed. 22nd 3120.B, 3030 B-2012 b. Bahan Organik 1) Zat Organik (KMnO4) **) mg/L 10 11 SNI 06-6989.22-2004 2) Deterjen (MBAS) **) mg/L 0,05 <0,01 SNI 06-6989.51-2005 c. Desinfektan dan hasil sampingnya 1) Chlorine (Cl2) **) mg/L 5 <0,01 18-34/IK/A (Spektrofotometri) Keterangan : *) = Peraturan Menteri Kesehatan RI Nomor 492/MENKES/PER/IV/2010
Tentang Persyaratan Kualitas Air Minum **) = Parameter terakreditasi oleh KAN No. LP-195-IDN < = Lebih kecil Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 24 dari 51 • Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-25/AM/06/2017 Uraian contoh : Air Minum (Sumur Gali 709 Sapan Sari) (GW-3) Koordinat : LS 01º 35’ 0‚69” BT 101º 08’ 37‚12" Metode pengambilan contoh : SNI-06-2412-1991 Tanggal pengambilan : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
NO PARAMETER SATUAN KADAR *) HASIL METODE
MAKSIMUM
I PARAMETER WAJIB 1 Parameter yang berhubungan langsung dengan kesehatan
a.Parameter Mikrobiologi 1) E. Coli **) Jml/100 ml 0 0 SNI ISO 9308-1:2010 2) Total Bakteri Koliform **) Jml/100 ml 0 8 SNI ISO 9308-1:2010 b. Kimia an-organik 1) Arsen mg/L 0,01 <0,005 APHA Ed. 22nd 3114.B - 2012 2) Fluorida (F) **) mg/L 1,5 0,06 APHA Ed. 22nd 4500-F.D-2012 3) Total Kromium (Cr) **) mg/L 0,05 <0,003 APHA Ed. 22nd 3120.B, 3030 B-2012 4) Kadmium (Cd) **) mg/L 0,003 <0,002 APHA Ed. 22nd 3120.B, 3030 B-2012 5) Nitrit (sebagai NO2) **) mg/L 3 <0,002 18-36/IK/A (test kit) 6) Nitrat, (sebagai NO3) **) mg/L 50 19 18-30/IK/A (test kit) 7) Sianida (CN) **) mg/L 0,07 <0,005 APHA Ed. 22nd 4500-CN.E-2012 8) Selenium (Se) mg/L 0,01 <0,002 APHA Ed. 22nd 3114.B - 2012
2 Parameter yang tidak langsung berhubungan dengan kesehatan a. Parameter Fisik
1) Bau (insitu) **) - Tdk.berbau Tdk
berbau SNI 06-6860-2002 2) Warna **) TCU 15 2 18-11/IK/A (Spektrofotometri) 3) Total zat padat terlarut (TDS) **) mg/L 500 62 18-6/IK/A (Konduktometri) 4) Kekeruhan **) NTU 5 2 SNI 06-6989.25-2005 5) Rasa **) - Tdk.berasa Tdk berasa SNI 06-6859-2002 6) Suhu (insitu) **) oC Suhu udara + 3 24 SNI 06-6989.23-2005
b. Parameter kimiawi 1) Aluminium (Al) **) mg/L 0,2 <0,004 APHA Ed. 22nd 3120.B, 3030 B-2012 2) Besi (Fe) **) mg/L 0,3 0,02 APHA Ed. 22nd 3120.B, 3030 B-2012 3) Kesadahan **) mg/L 500 37 SNI 06-6989.12-2004 4) Khlorida (Cl) **) mg/L 250 6 SNI 06-6989.19-2009 5) Mangan (Mn) **) mg/L 0,4 0,03 APHA Ed. 22nd 3120.B, 3030 B-2012 6) pH (insitu) **) - 6,5-8,5 7 SNI 06-6989.11-2004 7) Seng (Zn) **) mg/L 3 0,02 APHA Ed. 22nd 3120.B, 3030 B-2012 8) Sulfat **) mg/L 250 <0,3 SNI 06-6989.20-2009 9) Tembaga (Cu) **) mg/L 2 <0,009 APHA Ed. 22nd 3120.B, 3030 B-2012 10) Amonia **) mg/L 1,5 1 SNI 06-6989.30-2005 II PARAMETER TAMBAHAN KIMIAWI a. Bahan Anorganik 1) Air Raksa (Hg) mg/L 0,001 <0,0005 APHA Ed. 22nd 3112.B - 2012 2) Antimon (Sb) mg/L 0,02 <0,002 APHA Ed. 22nd 3120.B, 3030 B-2012 3) Barium (Ba) **) mg/L 0,7 <0,004 APHA Ed. 22nd 3120.B, 3030 B-2012 4) Boron (B) **) mg/L 0,5 <0,02 APHA Ed. 22nd 3120.B, 3030 B-2012 5) Molybdenum (Mo) mg/L 0,07 <0,02 APHA Ed. 22nd 3120.B, 3030 B-2012 6) Nikel (Ni) **) mg/L 0,07 <0,004 APHA Ed. 22nd 3120.B, 3030 B-2012 7) Sodium (Na) **) mg/L 200 4 APHA Ed. 22nd 3120 B, 3030 B-2012 8) Timbal (Pb) **) mg/L 0,01 <0,004 APHA Ed. 22nd 3120.B, 3030 B-2012 b. Bahan Organik 1) Zat Organik (KMnO4) **) mg/L 10 4 SNI 06-6989.22-2004 2) Deterjen (MBAS) **) mg/L 0,05 <0,01 SNI 06-6989.51-2005 c. Desinfektan dan hasil sampingnya 1) Chlorine (Cl2) **) mg/L 5 <0,01 18-34/IK/A (Spektrofotometri) Keterangan : *) = Peraturan Menteri Kesehatan RI Nomor 492/MENKES/PER/IV/2010
Tentang Persyaratan Kualitas Air Minum **) = Parameter terakreditasi oleh KAN No. LP-195-IDN < = Lebih kecil Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 25 dari 51 • Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-26/AM/06/2017 Uraian contoh : Air Minum (Sumur Gali 709 Pinang Awan) (GW-2) Koordinat : LS 01º 34’ 44‚43” BT 101º 08’ 0‚25" Metode pengambilan contoh : SNI-06-2412-1991 Tanggal pengambilan : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
NO PARAMETER SATUAN KADAR *) HASIL METODE
MAKSIMUM
I PARAMETER WAJIB 1 Parameter yang berhubungan langsung dengan kesehatan
a.Parameter Mikrobiologi 1) E. Coli **) Jml/100 ml 0 0 SNI ISO 9308-1:2010 2) Total Bakteri Koliform **) Jml/100 ml 0 4 SNI ISO 9308-1:2010 b. Kimia an-organik 1) Arsen mg/L 0,01 <0,005 APHA Ed. 22nd 3114.B - 2012 2) Fluorida (F) **) mg/L 1,5 <0,01 APHA Ed. 22nd 4500-F.D-2012 3) Total Kromium (Cr) **) mg/L 0,05 <0,003 APHA Ed. 22nd 3120.B, 3030 B-2012 4) Kadmium (Cd) **) mg/L 0,003 <0,002 APHA Ed. 22nd 3120.B, 3030 B-2012 5) Nitrit (sebagai NO2) **) mg/L 3 <0,002 18-36/IK/A (test kit) 6) Nitrat, (sebagai NO3) **) mg/L 50 0,4 18-30/IK/A (test kit) 7) Sianida (CN) **) mg/L 0,07 <0,005 APHA Ed. 22nd 4500-CN.E-2012 8) Selenium (Se) mg/L 0,01 <0,002 APHA Ed. 22nd 3114.B - 2012
2 Parameter yang tidak langsung berhubungan dengan kesehatan a. Parameter Fisik
1) Bau (insitu) **) - Tdk.berbau Tdk
berbau SNI 06-6860-2002 2) Warna **) TCU 15 3 18-11/IK/A (Spektrofotometri) 3) Total zat padat terlarut (TDS) **) mg/L 500 29 18-6/IK/A (Konduktometri) 4) Kekeruhan **) NTU 5 <1 SNI 06-6989.25-2005 5) Rasa **) - Tdk.berasa Tdk berasa SNI 06-6859-2002 6) Suhu (insitu) **) oC Suhu udara + 3 23 SNI 06-6989.23-2005
b. Parameter kimiawi 1) Aluminium (Al) **) mg/L 0,2 <0,004 APHA Ed. 22nd 3120.B, 3030 B-2012 2) Besi (Fe) **) mg/L 0,3 0,03 APHA Ed. 22nd 3120.B, 3030 B-2012 3) Kesadahan **) mg/L 500 13 SNI 06-6989.12-2004 4) Khlorida (Cl) **) mg/L 250 4 SNI 06-6989.19-2009 5) Mangan (Mn) **) mg/L 0,4 0,09 APHA Ed. 22nd 3120.B, 3030 B-2012 6) pH (insitu) **) - 6,5-8,5 6,47 SNI 06-6989.11-2004 7) Seng (Zn) **) mg/L 3 0,01 APHA Ed. 22nd 3120.B, 3030 B-2012 8) Sulfat **) mg/L 250 <0,3 SNI 06-6989.20-2009 9) Tembaga (Cu) **) mg/L 2 <0,009 APHA Ed. 22nd 3120.B, 3030 B-2012 10) Amonia **) mg/L 1,5 0,04 SNI 06-6989.30-2005 II PARAMETER TAMBAHAN KIMIAWI a. Bahan Anorganik 1) Air Raksa (Hg) mg/L 0,001 <0,0005 APHA Ed. 22nd 3112.B - 2012 2) Antimon (Sb) mg/L 0,02 <0,002 APHA Ed. 22nd 3120.B, 3030 B-2012 3) Barium (Ba) **) mg/L 0,7 <0,004 APHA Ed. 22nd 3120.B, 3030 B-2012 4) Boron (B) **) mg/L 0,5 <0,02 APHA Ed. 22nd 3120.B, 3030 B-2012 5) Molybdenum (Mo) mg/L 0,07 <0,02 APHA Ed. 22nd 3120.B, 3030 B-2012 6) Nikel (Ni) **) mg/L 0,07 <0,004 APHA Ed. 22nd 3120.B, 3030 B-2012 7) Sodium (Na) **) mg/L 200 3 APHA Ed. 22nd 3120 B, 3030 B-2012 8) Timbal (Pb) **) mg/L 0,01 <0,004 APHA Ed. 22nd 3120.B, 3030 B-2012 b. Bahan Organik 1) Zat Organik (KMnO4) **) mg/L 10 4 SNI 06-6989.22-2004 2) Deterjen (MBAS) **) mg/L 0,05 <0,01 SNI 06-6989.51-2005 c. Desinfektan dan hasil sampingnya 1) Chlorine (Cl2) **) mg/L 5 <0,01 18-34/IK/A (Spektrofotometri) Keterangan : *) = Peraturan Menteri Kesehatan RI Nomor 492/MENKES/PER/IV/2010
Tentang Persyaratan Kualitas Air Minum **) = Parameter terakreditasi oleh KAN No. LP-195-IDN < = Lebih kecil Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 26 dari 51 • Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-27/AP/06/2017 Uraian contoh : Air Permukaan (Bagian Hulu Sungai Batang Luki - SW 7) Koordinat : LS 01º 36’ 0‚61” BT 101º 09’ 03‚30" Metode pengambilan contoh : SNI 6989.57-2008 Tanggal pengambilan : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengujian NO PARAMETER SATUAN BAKU *) HASIL METODE MUTU
A. FISIKA 1 Temperatur (insitu) **) °C Deviasi 3 25 SNI 06-6989.23-2005 2 Zat padat terlarut (TDS) **) mg/L 1.000 92 18-6/IK/A (Konduktometri) 3 Zat padat tersuspensi (TSS) **) mg/L 50 5 18-7/IK/A (Spektrofotometri)
B. KIMIA 1 pH (Insitu) **) - 6-9 6,50 SNI 06-6989.11-2004 2 Oksigen Terlarut (DO) insitu mg/L 4 5,9 SNI 06-6989.14-2004 3 BOD5 **) mg/L 3 3 SNI 6989.72-2009 4 COD **) mg/L 25 11 SNI 6989.2-2009 5 Fosfat (PO4) **) mg/L 0,2 <0,03 SNI 06-6989.31-2005 6 Nitrat (NO3-N) mg/L 10 <0,05 18-30/IK/A (test kit) 7 Arsen (As) mg/L 1 <0,005 APHA Ed. 22nd 3114.B - 2012 8 Kobalt (Co) **) mg/L 0,2 <0,004 APHA Ed. 22nd 3120.B, 3030.B-2012 9 Boron (B) **) mg/L 1 0,04 APHA Ed. 22nd 3120.B, 3030.B-2012
10 Selenium (Se) mg/L 0,05 <0,002 APHA Ed. 22nd 3114.B-2012 11 Khromium (Cr) **) mg/L 0,05 <0,01 SNI 6989.71-2009 12 Sianida (CN) **) mg/L 0,02 <0,005 APHA Ed. 22nd 4500-CN.E-2012 13 Nitrit (NO2-N) **) mg/L 0,06 <0,004 18-36/IK/A (test kit) 14 Fluorida (F) **) mg/L 1,5 0,3 APHA Ed. 22nd 4500-F.D-2012 15 Sulfida (H2S) **) mg/L 0,002 <0,002 APHA Ed. 22nd 4500-S2.D-2012 16 Tembaga (Cu) **) mg/L 0,02 <0,009 APHA Ed. 22nd 3120.B, 3030.B-2012 17 Khlorin bebas (Cl2) **) mg/L 0,03 <0,01 18-34/IK/A (Spektrofotometri) 18 Timbal (Pb) **) mg/L 0,03 <0,004 APHA Ed. 22nd 3120.B, 3030.B-2012 19 Air raksa (Hg) mg/L 0,002 <0,0005 APHA Ed. 22nd 3112.B - 2012 20 Seng (Zn) **) mg/L 0,05 0,009 APHA Ed. 22nd 3120.B, 3030.B-2012 21 Kadmium (Cd) **) mg/L 0,01 <0,002 APHA Ed. 22nd 3120.B, 3030.B-2012 22 Minyak & Lemak **) Bg/L 750 <200 Ekstraksi-Spektrofotometri 23 Detergen (MBAS) **) Bg/L 200 <10 SNI 06-6989.51-2005 24 Fenol **) Bg/L 1 <1 APHA Ed. 22nd 5530-Phenol.B-D-2012
C. MIKROBIOLOGI 1 Koliform Tinja **) MPN/100ml 1.000 790 APHA Ed. 22nd 9221 E-2012 2 Total Koliform **) MPN/100ml 5000 1.100 APHA Ed. 22nd 9221.B-2012
Keterangan : *) = PERATURAN GUBERNUR SUMATERA BARAT NOMOR 5 TAHUN 2008 Tentang Penetapan Kriteria Mutu Air Sungai Di Propinsi Sumatera Barat Kriteria Mutu Air Sungai Berdasarkan Kelas II **) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDN
< = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 27 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-28/AP/06/2017 Uraian contoh : Air Permukaan (Bagian Hulu Sungani Batang Bangko Karuah - SW 1) Koordinat : LS 01º 37’ 31,19‘ BT 101º 07’ 37‚06" Metode pengambilan contoh : SNI 6989.57-2008 Tanggal pengambilan : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengujian NO PARAMETER SATUAN BAKU *) HASIL METODE MUTU
A. FISIKA 1 Temperatur (insitu) **) °C Deviasi 3 24 SNI 06-6989.23-2005 2 Zat padat terlarut (TDS) **) mg/L 1.000 14 18-6/IK/A (Konduktometri) 3 Zat padat tersuspensi (TSS) **) mg/L 50 3 18-7/IK/A (Spektrofotometri)
B. KIMIA 1 pH (Insitu) **) - 6-9 6,2 SNI 06-6989.11-2004 2 Oksigen Terlarut (DO) insitu mg/L 4 5,4 SNI 06-6989.14-2004 3 BOD5 **) mg/L 3 3 SNI 6989.72-2009 4 COD **) mg/L 25 14 SNI 6989.2-2009 5 Fosfat (PO4) **) mg/L 0,2 <0,03 SNI 06-6989.31-2005 6 Nitrat (NO3-N) mg/L 10 0,1 18-30/IK/A (test kit) 7 Arsen (As) mg/L 1 <0,005 APHA Ed. 22nd 3114.B - 2012 8 Kobalt (Co) **) mg/L 0,2 <0,004 APHA Ed. 22nd 3120.B, 3030.B-2012 9 Boron (B) **) mg/L 1 <0,02 APHA Ed. 22nd 3120.B, 3030.B-2012
10 Selenium (Se) mg/L 0,05 <0,002 APHA Ed. 22nd 3114.B-2012 11 Khromium (Cr) **) mg/L 0,05 <0,01 SNI 6989.71-2009 12 Sianida (CN) **) mg/L 0,02 <0,005 APHA Ed. 22nd 4500-CN.E-2012 13 Nitrit (NO2-N) **) mg/L 0,06 <0,004 18-36/IK/A (test kit) 14 Fluorida (F) **) mg/L 1,5 <0,01 APHA Ed. 22nd 4500-F.D-2012 15 Sulfida (H2S) **) mg/L 0,002 <0,002 APHA Ed. 22nd 4500-S2.D-2012 16 Tembaga (Cu) **) mg/L 0,02 <0,009 APHA Ed. 22nd 3120.B, 3030.B-2012 17 Khlorin bebas (Cl2) **) mg/L 0,03 <0,01 18-34/IK/A (Spektrofotometri) 18 Timbal (Pb) **) mg/L 0,03 <0,004 APHA Ed. 22nd 3120.B, 3030.B-2012 19 Air raksa (Hg) mg/L 0,002 <0,0005 APHA Ed. 22nd 3112.B - 2012 20 Seng (Zn) **) mg/L 0,05 <0,008 APHA Ed. 22nd 3120.B, 3030.B-2012 21 Kadmium (Cd) **) mg/L 0,01 <0,002 APHA Ed. 22nd 3120.B, 3030.B-2012 22 Minyak & Lemak **) Bg/L 750 <200 Ekstraksi-Spektrofotometri 23 Detergen (MBAS) **) Bg/L 200 <0,01 SNI 06-6989.51-2005 24 Fenol **) Bg/L 1 <1 APHA Ed. 22nd 5530-Phenol.B-D-2012
C. MIKROBIOLOGI 1 Koliform Tinja **) MPN/100ml 1.000 1.200 APHA Ed. 22nd 9221 E-2012 2 Total Koliform **) MPN/100ml 5000 1.500 APHA Ed. 22nd 9221.B-2012
Keterangan : *) = PERATURAN GUBERNUR SUMATERA BARAT NOMOR 5 TAHUN 2008 Tentang Penetapan Kriteria Mutu Air Sungai Di Propinsi Sumatera Barat Kriteria Mutu Air Sungai Berdasarkan Kelas II **) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDN
< = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 28 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-29/AP/06/2017 Uraian contoh : Air Permukaan (Bagian tengah Sungai Batang Bangko Karuah - SW2) Koordinat : LS 01º 36’ 59‚07” BT 101º 07’ 31‚19" Metode pengambilan contoh : SNI 6989.57-2008 Tanggal pengambilan : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengujian NO PARAMETER SATUAN BAKU *) HASIL METODE MUTU
A. FISIKA 1 Temperatur (insitu) **) °C Deviasi 3 24 SNI 06-6989.23-2005 2 Zat padat terlarut (TDS) **) mg/L 1.000 26 18-6/IK/A (Konduktometri) 3 Zat padat tersuspensi (TSS) **) mg/L 50 4 18-7/IK/A (Spektrofotometri)
B. KIMIA 1 pH (Insitu) **) - 6-9 6,4 SNI 06-6989.11-2004 2 Oksigen Terlarut (DO) insitu mg/L 4 4,9 SNI 06-6989.14-2004 3 BOD5 **) mg/L 3 4 SNI 6989.72-2009 4 COD **) mg/L 25 18 SNI 6989.2-2009 5 Fosfat (PO4) **) mg/L 0,2 <0,03 SNI 06-6989.31-2005 6 Nitrat (NO3-N) mg/L 10 <0,05 18-30/IK/A (test kit) 7 Arsen (As) mg/L 1 <0,005 APHA Ed. 22nd 3114.B - 2012 8 Kobalt (Co) **) mg/L 0,2 <0,004 APHA Ed. 22nd 3120.B, 3030.B-2012 9 Boron (B) **) mg/L 1 <0,02 APHA Ed. 22nd 3120.B, 3030.B-2012
10 Selenium (Se) mg/L 0,05 <0,002 APHA Ed. 22nd 3114.B-2012 11 Khromium (Cr) **) mg/L 0,05 <0,01 SNI 6989.71-2009 12 Sianida (CN) **) mg/L 0,02 <0,005 APHA Ed. 22nd 4500-CN.E-2012 13 Nitrit (NO2-N) **) mg/L 0,06 <0,004 18-36/IK/A (test kit) 14 Fluorida (F) **) mg/L 1,5 <0,01 APHA Ed. 22nd 4500-F.D-2012 15 Sulfida (H2S) **) mg/L 0,002 <0,002 APHA Ed. 22nd 4500-S2.D-2012 16 Tembaga (Cu) **) mg/L 0,02 <0,009 APHA Ed. 22nd 3120.B, 3030.B-2012 17 Khlorin bebas (Cl2) **) mg/L 0,03 <0,01 18-34/IK/A (Spektrofotometri) 18 Timbal (Pb) **) mg/L 0,03 <0,004 APHA Ed. 22nd 3120.B, 3030.B-2012 19 Air raksa (Hg) mg/L 0,002 <0,0005 APHA Ed. 22nd 3112.B - 2012 20 Seng (Zn) **) mg/L 0,05 0,01 APHA Ed. 22nd 3120.B, 3030.B-2012 21 Kadmium (Cd) **) mg/L 0,01 <0,002 APHA Ed. 22nd 3120.B, 3030.B-2012 22 Minyak & Lemak **) Bg/L 750 <200 Ekstraksi-Spektrofotometri 23 Detergen (MBAS) **) Bg/L 200 <10 SNI 06-6989.51-2005 24 Fenol **) Bg/L 1 <1 APHA Ed. 22nd 5530-Phenol.B-D-2012
C. MIKROBIOLOGI 1 Koliform Tinja **) MPN/100ml 1.000 1.400 APHA Ed. 22nd 9221 E-2012 2 Total Koliform **) MPN/100ml 5000 1.700 APHA Ed. 22nd 9221.B-2012
Keterangan : *) = PERATURAN GUBERNUR SUMATERA BARAT NOMOR 5 TAHUN 2008 Tentang Penetapan Kriteria Mutu Air Sungai Di Propinsi Sumatera Barat Kriteria Mutu Air Sungai Berdasarkan Kelas II **) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDN
< = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 29 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-30/AP/06/2017 Uraian contoh : Air Permukaan (Bagian Hulu Sungai Batang Bangko Janiah - SW5) Koordinat : LS 01º 36’ 22,01” BT 101º 07’ 46‚02" Metode pengambilan contoh : SNI 6989.57-2008 Tanggal pengambilan : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengujian NO PARAMETER SATUAN BAKU *) HASIL METODE MUTU
A. FISIKA 1 Temperatur (insitu) **) °C Deviasi 3 22 SNI 06-6989.23-2005 2 Zat padat terlarut (TDS) **) mg/L 1.000 131 18-6/IK/A (Konduktometri) 3 Zat padat tersuspensi (TSS) **) mg/L 50 2 18-7/IK/A (Spektrofotometri)
B. KIMIA 1 pH (Insitu) **) - 6-9 6,2 SNI 06-6989.11-2004 2 Oksigen Terlarut (DO) insitu mg/L 4 5,7 SNI 06-6989.14-2004 3 BOD5 **) mg/L 3 3 SNI 6989.72-2009 4 COD **) mg/L 25 12 SNI 6989.2-2009 5 Fosfat (PO4) **) mg/L 0,2 <0,03 SNI 06-6989.31-2005 6 Nitrat (NO3-N) mg/L 10 <0,05 18-30/IK/A (test kit) 7 Arsen (As) mg/L 1 <0,005 APHA Ed. 22nd 3114.B - 2012 8 Kobalt (Co) **) mg/L 0,2 0,006 APHA Ed. 22nd 3120.B, 3030.B-2012 9 Boron (B) **) mg/L 1 <0,02 APHA Ed. 22nd 3120.B, 3030.B-2012
10 Selenium (Se) mg/L 0,05 <0,002 APHA Ed. 22nd 3114.B-2012 11 Khromium (Cr) **) mg/L 0,05 <0,01 SNI 6989.71-2009 12 Sianida (CN) **) mg/L 0,02 <0,005 APHA Ed. 22nd 4500-CN.E-2012 13 Nitrit (NO2-N) **) mg/L 0,06 <0,004 18-36/IK/A (test kit) 14 Fluorida (F) **) mg/L 1,5 <0,01 APHA Ed. 22nd 4500-F.D-2012 15 Sulfida (H2S) **) mg/L 0,002 <0,002 APHA Ed. 22nd 4500-S2.D-2012 16 Tembaga (Cu) **) mg/L 0,02 <0,009 APHA Ed. 22nd 3120.B, 3030.B-2012 17 Khlorin bebas (Cl2) **) mg/L 0,03 <0,01 18-34/IK/A (Spektrofotometri) 18 Timbal (Pb) **) mg/L 0,03 <0,004 APHA Ed. 22nd 3120.B, 3030.B-2012 19 Air raksa (Hg) mg/L 0,002 <0,0005 APHA Ed. 22nd 3112.B - 2012 20 Seng (Zn) **) mg/L 0,05 0,02 APHA Ed. 22nd 3120.B, 3030.B-2012 21 Kadmium (Cd) **) mg/L 0,01 <0,002 APHA Ed. 22nd 3120.B, 3030.B-2012 22 Minyak & Lemak **) Bg/L 750 <200 Ekstraksi-Spektrofotometri 23 Detergen (MBAS) **) Bg/L 200 <10 SNI 06-6989.51-2005 24 Fenol **) Bg/L 1 <1 APHA Ed. 22nd 5530-Phenol.B-D-2012
C. MIKROBIOLOGI 1 Koliform Tinja **) MPN/100ml 1.000 940 APHA Ed. 22nd 9221 E-2012 2 Total Koliform **) MPN/100ml 5000 1.200 APHA Ed. 22nd 9221.B-2012
Keterangan : *) = PERATURAN GUBERNUR SUMATERA BARAT NOMOR 5 TAHUN 2008 Tentang Penetapan Kriteria Mutu Air Sungai Di Propinsi Sumatera Barat Kriteria Mutu Air Sungai Berdasarkan Kelas II **) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDN
< = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 30 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-31/AP/06/2017 Uraian contoh : Air Permukaan (Bagian Tengah Sungai Batang Banko Janiah - SW4) Koordinat : LS 01º 36’ 32‚44” BT 101º 08’ 02‚95" Metode pengambilan contoh : SNI 6989.57-2008 Tanggal pengambilan : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengujian NO PARAMETER SATUAN BAKU *) HASIL METODE MUTU
A. FISIKA 1 Temperatur (insitu) **) °C Deviasi 3 24 SNI 06-6989.23-2005 2 Zat padat terlarut (TDS) **) mg/L 1.000 150 18-6/IK/A (Konduktometri) 3 Zat padat tersuspensi (TSS) **) mg/L 50 7 18-7/IK/A (Spektrofotometri)
B. KIMIA 1 pH (Insitu) **) - 6-9 6,1 SNI 06-6989.11-2004 2 Oksigen Terlarut (DO) insitu mg/L 4 5,9 SNI 06-6989.14-2004 3 BOD5 **) mg/L 3 3 SNI 6989.72-2009 4 COD **) mg/L 25 11 SNI 6989.2-2009 5 Fosfat (PO4) **) mg/L 0,2 <0,03 SNI 06-6989.31-2005 6 Nitrat (NO3-N) mg/L 10 <0,05 18-30/IK/A (test kit) 7 Arsen (As) mg/L 1 <0,005 APHA Ed. 22nd 3114.B - 2012 8 Kobalt (Co) **) mg/L 0,2 0,005 APHA Ed. 22nd 3120.B, 3030.B-2012 9 Boron (B) **) mg/L 1 <0,02 APHA Ed. 22nd 3120.B, 3030.B-2012
10 Selenium (Se) mg/L 0,05 <0,002 APHA Ed. 22nd 3114.B-2012 11 Khromium (Cr) **) mg/L 0,05 <0,01 SNI 6989.71-2009 12 Sianida (CN) **) mg/L 0,02 <0,005 APHA Ed. 22nd 4500-CN.E-2012 13 Nitrit (NO2-N) **) mg/L 0,06 <0,004 18-36/IK/A (test kit) 14 Fluorida (F) **) mg/L 1,5 0,01 APHA Ed. 22nd 4500-F.D-2012 15 Sulfida (H2S) **) mg/L 0,002 <0,002 APHA Ed. 22nd 4500-S2.D-2012 16 Tembaga (Cu) **) mg/L 0,02 <0,009 APHA Ed. 22nd 3120.B, 3030.B-2012 17 Khlorin bebas (Cl2) **) mg/L 0,03 <0,01 18-34/IK/A (Spektrofotometri) 18 Timbal (Pb) **) mg/L 0,03 <0,004 APHA Ed. 22nd 3120.B, 3030.B-2012 19 Air raksa (Hg) mg/L 0,002 <0,0005 APHA Ed. 22nd 3112.B - 2012 20 Seng (Zn) **) mg/L 0,05 0,03 APHA Ed. 22nd 3120.B, 3030.B-2012 21 Kadmium (Cd) **) mg/L 0,01 <0,002 APHA Ed. 22nd 3120.B, 3030.B-2012 22 Minyak & Lemak **) Bg/L 750 <200 Ekstraksi-Spektrofotometri 23 Detergen (MBAS) **) Bg/L 200 <10 SNI 06-6989.51-2005 24 Fenol **) Bg/L 1 <1 APHA Ed. 22nd 5530-Phenol.B-D-2012
C. MIKROBIOLOGI 1 Koliform Tinja **) MPN/100ml 1.000 1.200 APHA Ed. 22nd 9221 E-2012 2 Total Koliform **) MPN/100ml 5000 1.500 APHA Ed. 22nd 9221.B-2012
Keterangan : *) = PERATURAN GUBERNUR SUMATERA BARAT NOMOR 5 TAHUN 2008 Tentang Penetapan Kriteria Mutu Air Sungai Di Propinsi Sumatera Barat Kriteria Mutu Air Sungai Berdasarkan Kelas II **) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDN
< = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 31 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-32/AP/06/2017 Uraian contoh : Air Permukaan (Bagian Hilir Sungai Batang Luki SW-8) Koordinat : LS 01º 36’ 0‚61” BT 101º 09’ 03‚30" Metode pengambilan contoh : SNI 6989.57-2008 Tanggal pengambilan : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengujian NO PARAMETER SATUAN BAKU *) HASIL METODE MUTU
A. FISIKA 1 Temperatur (insitu) **) °C Deviasi 3 24 SNI 06-6989.23-2005 2 Zat padat terlarut (TDS) **) mg/L 1.000 92 18-6/IK/A (Konduktometri) 3 Zat padat tersuspensi (TSS) **) mg/L 50 4 18-7/IK/A (Spektrofotometri)
B. KIMIA 1 pH (Insitu) **) - 6-9 6,53 SNI 06-6989.11-2004 2 Oksigen Terlarut (DO) insitu mg/L 4 5,6 SNI 06-6989.14-2004 3 BOD5 **) mg/L 3 3 SNI 6989.72-2009 4 COD **) mg/L 25 13 SNI 6989.2-2009 5 Fosfat (PO4) **) mg/L 0,2 0,15 SNI 06-6989.31-2005 6 Nitrat (NO3-N) mg/L 10 <0,05 18-30/IK/A (test kit) 7 Arsen (As) mg/L 1 <0,005 APHA Ed. 22nd 3114.B - 2012 8 Kobalt (Co) **) mg/L 0,2 <0,004 APHA Ed. 22nd 3120.B, 3030.B-2012 9 Boron (B) **) mg/L 1 0,043 APHA Ed. 22nd 3120.B, 3030.B-2012
10 Selenium (Se) mg/L 0,05 <0,002 APHA Ed. 22nd 3114.B-2012 11 Khromium (Cr) **) mg/L 0,05 <0,01 SNI 6989.71-2009 12 Sianida (CN) **) mg/L 0,02 <0,005 APHA Ed. 22nd 4500-CN.E-2012 13 Nitrit (NO2-N) **) mg/L 0,06 <0,004 18-36/IK/A (test kit) 14 Fluorida (F) **) mg/L 1,5 0,2 APHA Ed. 22nd 4500-F.D-2012 15 Sulfida (H2S) **) mg/L 0,002 <0,002 APHA Ed. 22nd 4500-S2.D-2012 16 Tembaga (Cu) **) mg/L 0,02 <0,009 APHA Ed. 22nd 3120.B, 3030.B-2012 17 Khlorin bebas (Cl2) **) mg/L 0,03 <0,01 18-34/IK/A (Spektrofotometri) 18 Timbal (Pb) **) mg/L 0,03 <0,004 APHA Ed. 22nd 3120.B, 3030.B-2012 19 Air raksa (Hg) mg/L 0,002 <0,0005 APHA Ed. 22nd 3112.B - 2012 20 Seng (Zn) **) mg/L 0,05 <0,008 APHA Ed. 22nd 3120.B, 3030.B-2012 21 Kadmium (Cd) **) mg/L 0,01 <0,002 APHA Ed. 22nd 3120.B, 3030.B-2012 22 Minyak & Lemak **) Bg/L 750 <200 Ekstraksi-Spektrofotometri/SNI 6989.10-2011 23 Detergen (MBAS) **) Bg/L 200 <10 SNI 06-6989.51-2005 24 Fenol **) Bg/L 1 <1 APHA Ed. 22nd 5530-Phenol.B-D-2012
C. MIKROBIOLOGI 1 Koliform Tinja **) MPN/100ml 1.000 1.300 APHA Ed. 22nd 9221 E-2012 2 Total Koliform **) MPN/100ml 5000 2.400 APHA Ed. 22nd 9221.B-2012
Keterangan : *) = PERATURAN GUBERNUR SUMATERA BARAT NOMOR 5 TAHUN 2008 Tentang Penetapan Kriteria Mutu Air Sungai Di Propinsi Sumatera Barat Kriteria Mutu Air Sungai Berdasarkan Kelas II **) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDN
< = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 32 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-33/AP/06/2017 Uraian contoh : Air Permukaan (Bagian Hilir Sungai Batang Bangko Janiah - SW6) Koordinat : LS 01º 37’ 58‚27” BT 101º 08’ 32‚18" Metode pengambilan contoh : SNI 6989.57-2008 Tanggal pengambilan : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengujian NO PARAMETER SATUAN BAKU *) HASIL METODE MUTU
A. FISIKA 1 Temperatur (insitu) **) °C Deviasi 3 24 SNI 06-6989.23-2005 2 Zat padat terlarut (TDS) **) mg/L 1.000 92 18-6/IK/A (Konduktometri) 3 Zat padat tersuspensi (TSS) **) mg/L 50 5 18-7/IK/A (Spektrofotometri)
B. KIMIA 1 pH (Insitu) **) - 6-9 6,50 SNI 06-6989.11-2004 2 Oksigen Terlarut (DO) insitu mg/L 4 5,6 SNI 06-6989.14-2004 3 BOD5 **) mg/L 3 3 SNI 6989.72-2009 4 COD **) mg/L 25 13 SNI 6989.2-2009 5 Fosfat (PO4) **) mg/L 0,2 <0,03 SNI 06-6989.31-2005 6 Nitrat (NO3-N) mg/L 10 <0,05 18-30/IK/A (test kit) 7 Arsen (As) mg/L 1 <0,005 APHA Ed. 22nd 3114.B - 2012 8 Kobalt (Co) **) mg/L 0,2 <0,004 APHA Ed. 22nd 3120.B, 3030.B-2012 9 Boron (B) **) mg/L 1 0,04 APHA Ed. 22nd 3120.B, 3030.B-2012
10 Selenium (Se) mg/L 0,05 <0,002 APHA Ed. 22nd 3114.B-2012 11 Khromium (Cr) **) mg/L 0,05 <0,01 SNI 6989.71-2009 12 Sianida (CN) **) mg/L 0,02 <0,005 APHA Ed. 22nd 4500-CN.E-2012 13 Nitrit (NO2-N) **) mg/L 0,06 <0,004 18-36/IK/A (test kit) 14 Fluorida (F) **) mg/L 1,5 0,2 APHA Ed. 22nd 4500-F.D-2012 15 Sulfida (H2S) **) mg/L 0,002 <0,002 APHA Ed. 22nd 4500-S2.D-2012 16 Tembaga (Cu) **) mg/L 0,02 <0,009 APHA Ed. 22nd 3120.B, 3030.B-2012 17 Khlorin bebas (Cl2) **) mg/L 0,03 <0,01 18-34/IK/A (Spektrofotometri) 18 Timbal (Pb) **) mg/L 0,03 <0,004 APHA Ed. 22nd 3120.B, 3030.B-2012 19 Air raksa (Hg) mg/L 0,002 <0,0005 APHA Ed. 22nd 3112.B - 2012 20 Seng (Zn) **) mg/L 0,05 0,01 APHA Ed. 22nd 3120.B, 3030.B-2012 21 Kadmium (Cd) **) mg/L 0,01 <0,002 APHA Ed. 22nd 3120.B, 3030.B-2012 22 Minyak & Lemak **) Bg/L 750 <200 Ekstraksi-Spektrofotometri 23 Detergen (MBAS) **) Bg/L 200 <10 SNI 06-6989.51-2005 24 Fenol **) Bg/L 1 <1 APHA Ed. 22nd 5530-Phenol.B-D-2012
C. MIKROBIOLOGI 1 Koliform Tinja **) MPN/100ml 1.000 1.300 APHA Ed. 22nd 9221 E-2012 2 Total Koliform **) MPN/100ml 5000 2.400 APHA Ed. 22nd 9221.B-2012
Keterangan : *) = PERATURAN GUBERNUR SUMATERA BARAT NOMOR 5 TAHUN 2008 Tentang Penetapan Kriteria Mutu Air Sungai Di Propinsi Sumatera Barat Kriteria Mutu Air Sungai Berdasarkan Kelas II **) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDN
< = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 33 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-34/AP/06/2017 Uraian contoh : Air Permukaan (Bagian Tengah Sungai Batang Bangko Janiah - SW3) Koordinat : LS 01º 38’ 05‚40” BT 101º 08’ 07‚08" Metode pengambilan contoh : SNI 6989.57-2008 Tanggal pengambilan : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengujian NO PARAMETER SATUAN BAKU *) HASIL METODE MUTU
A. FISIKA 1 Temperatur (insitu) **) °C Deviasi 3 23 SNI 06-6989.23-2005 2 Zat padat terlarut (TDS) **) mg/L 1.000 150 18-6/IK/A (Konduktometri) 3 Zat padat tersuspensi (TSS) **) mg/L 50 6 18-7/IK/A (Spektrofotometri)
B. KIMIA 1 pH (Insitu) **) - 6-9 6,47 SNI 06-6989.11-2004 2 Oksigen Terlarut (DO) insitu mg/L 4 5,7 SNI 06-6989.14-2004 3 BOD5 **) mg/L 3 3 SNI 6989.72-2009 4 COD **) mg/L 25 12 SNI 6989.2-2009 5 Fosfat (PO4) **) mg/L 0,2 <0,03 SNI 06-6989.31-2005 6 Nitrat (NO3-N) mg/L 10 <0,05 18-30/IK/A (test kit) 7 Arsen (As) mg/L 1 <0,005 APHA Ed. 22nd 3114.B - 2012 8 Kobalt (Co) **) mg/L 0,2 0,005 APHA Ed. 22nd 3120.B, 3030.B-2012 9 Boron (B) **) mg/L 1 <0,02 APHA Ed. 22nd 3120.B, 3030.B-2012
10 Selenium (Se) mg/L 0,05 <0,002 APHA Ed. 22nd 3114.B-2012 11 Khromium (Cr) **) mg/L 0,05 <0,01 SNI 6989.71-2009 12 Sianida (CN) **) mg/L 0,02 <0,005 APHA Ed. 22nd 4500-CN.E-2012 13 Nitrit (NO2-N) **) mg/L 0,06 <0,004 18-36/IK/A (test kit) 14 Fluorida (F) **) mg/L 1,5 0,1 APHA Ed. 22nd 4500-F.D-2012 15 Sulfida (H2S) **) mg/L 0,002 <0,002 APHA Ed. 22nd 4500-S2.D-2012 16 Tembaga (Cu) **) mg/L 0,02 <0,009 APHA Ed. 22nd 3120.B, 3030.B-2012 17 Khlorin bebas (Cl2) **) mg/L 0,03 <0,01 18-34/IK/A (Spektrofotometri) 18 Timbal (Pb) **) mg/L 0,03 <0,004 APHA Ed. 22nd 3120.B, 3030.B-2012 19 Air raksa (Hg) mg/L 0,002 <0,0005 APHA Ed. 22nd 3112.B - 2012 20 Seng (Zn) **) mg/L 0,05 0,03 APHA Ed. 22nd 3120.B, 3030.B-2012 21 Kadmium (Cd) **) mg/L 0,01 <0,002 APHA Ed. 22nd 3120.B, 3030.B-2012 22 Minyak & Lemak **) Bg/L 750 <200 Ekstraksi-Spektrofotometri 23 Detergen (MBAS) **) Bg/L 200 <10 SNI 06-6989.51-2005 24 Fenol **) Bg/L 1 <1 APHA Ed. 22nd 5530-Phenol.B-D-2012
C. MIKROBIOLOGI 1 Koliform Tinja **) MPN/100ml 1.000 1.400 APHA Ed. 22nd 9221 E-2012 2 Total Koliform **) MPN/100ml 5000 1.700 APHA Ed. 22nd 9221.B-2012
Keterangan : *) = PERATURAN GUBERNUR SUMATERA BARAT NOMOR 5 TAHUN 2008 Tentang Penetapan Kriteria Mutu Air Sungai Di Propinsi Sumatera Barat Kriteria Mutu Air Sungai Berdasarkan Kelas II **) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Metode pengambilan contoh telah terakreditasi oleh KAN No. LP-195-IDN
< = Lebih kecil
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 34 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-35/TN/06/2017 Uraian contoh : Tanah (Area S-3) Koordinat : LS 01º 35’ 57‚56” BT 101º 08’ 57‚58" Tanggal diambil : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengujian
NO PARAMETER SATUAN HASIL METODE
1 Permeabilitas cm/jam 4,20 18-15/IK/TNH (Metode boodt, hukum Darcy)
2 Ruang Pori Total %vol 55,55 18-16/IK/TNH (Gravimetri)
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 35 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-36/TN/06/2017 Uraian contoh : Tanah (Area SQ-16) Koordinat : LS 01º 35’ 28‚70” BT 101º 07’ 40‚10" Tanggal diambil : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengujian
NO PARAMETER SATUAN HASIL METODE
1 Permeabilitas cm/jam 3,61 18-15/IK/TNH (Metode boodt, hukum Darcy)
2 Ruang Pori Total %vol 47,40 18-16/IK/TNH (Gravimetri)
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 36 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-37/TN/06/2017 Uraian contoh : Tanah (S-2) Koordinat : LS 01º 35’ 55‚16” BT 101º 08’ 33‚42" Tanggal diambil : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengujian
NO PARAMETER SATUAN HASIL METODE
1 Permeabilitas cm/jam 4,56 18-15/IK/TNH (Metode boodt, hukum Darcy)
2 Ruang Pori Total %vol 52,80 18-16/IK/TNH (Gravimetri)
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 37 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-38/TN/06/2017 Uraian contoh : Tanah (Area SQ 3B) Koordinat : LS 01º 38’ 03‚50” BT 101º 07’ 52‚70" Tanggal diambil : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengujian
NO PARAMETER SATUAN HASIL METODE
1 Permeabilitas cm/jam 3,39 18-15/IK/TNH (Metode boodt, hukum Darcy)
2 Ruang Pori Total %vol 48,72 18-16/IK/TNH (Gravimetri)
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 38 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-39/TN/06/2017 Uraian contoh : Tanah (Area SQ - 26) Koordinat : LS 01º 38’ 03‚50” BT 101º 07’ 47‚40" Tanggal diambil : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengujian
NO PARAMETER SATUAN HASIL METODE
1 Permeabilitas cm/jam 7,66 18-15/IK/TNH (Metode boodt, hukum Darcy)
2 Ruang Pori Total %vol 64,23 18-16/IK/TNH (Gravimetri)
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 39 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-40/TN/06/2017 Uraian contoh : Tanah (S1) Koordinat : LS 01º 37’ 38‚80” BT 101º 07’ 52‚70" Tanggal diambil : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengujian
NO PARAMETER SATUAN HASIL METODE
1 Permeabilitas cm/jam 2,75 18-15/IK/TNH (Metode boodt, hukum Darcy)
2 Ruang Pori Total %vol 47,41 18-16/IK/TNH (Gravimetri)
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 40 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-41/TN/06/2017 Uraian contoh : Tanah (S-4) Koordinat : LS 01º 37’ 49‚75” BT 101º 08’ 33‚42" Tanggal diambil : 08 Juni 2017 Tanggal diterima di Lab : 16 Juli 2017 Tanggal pengujian : 16 Juli 2017 sampai 25 Juli 2017
Hasil Pengujian
NO PARAMETER SATUAN HASIL METODE
1 Permeabilitas cm/jam 7,05 18-15/IK/TNH (Metode boodt, hukum Darcy)
2 Ruang Pori Total %vol 59,43 18-16/IK/TNH (Gravimetri)
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 41 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium.
• Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-42/TN/06/2017 Uraian contoh : Tanah (Area S-3) Koordinat : LS 01º 35’ 57‚56” BT 101º 08’ 57‚58" Tanggal diterima di Lab : 08 Juni 2017 Tanggal pengujian : 08 Juni 2017 sampai 25 Juli 2017
Hasil Pengujian
NO. PARAMETER SATUAN HASIL METODE
KIMIA TANAH
1 pH
- H2O *) - 5,47 18-1/IK/TNH (Elektrometri)
2 C. Organik *) % 3,69 18-3/IK/TNH (Spektrofotometri)
3 N. Total *) % 0,55 18-6/IK/TNH (Spektrofotometri)
4 P2O5 bray *) ppm 3,82 18-2/IK/TNH (Spektrofotometri)
5 Susunan kation (NH4-Act)
- Ca me/100 gr 4,27 18-13/IK/TNH (Spektrofotometri)
- Mg me/100 gr 0,75 18-13/IK/TNH (Spektrofotometri)
- K me/100 gr 1,08 18-13/IK/TNH (Spektrofotometri)
- Na me/100 gr 4,53 18-13/IK/TNH (Spektrofotometri)
6 Kapasitas Tukar Kation me/100 gr 11,97 18-13/IK/TNH (Spektrofotometri)
7 Kemasaman
- Al – Tukar me/100 gr 3,21 18-9/IK/TNH (Titrimetri)
- H – Tukar me/100 gr 2,65 18-9/IK/TNH (Titrimetri)
8 Tekstur
- Pasir % 0,61 18-10/IK/TNH (Gravimetri)
- Debu % 60,93 18-10/IK/TNH (Gravimetri)
- Liat % 38,46 18-10/IK/TNH (Gravimetri)
9 Kejenuhan Basa % 88,81 18-13/IK/TNH
Keterangan : *) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Riyanti Manajer Laboratorium Penguji
Halaman 42 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh
digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium. • Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-43/TN/06/2017 Uraian contoh : Tanah (Area SQ-16) Koordinat : LS 01º 35’ 28‚70” BT 101º 07’ 40‚10" Tanggal diambil : 08 Juni 2017 Tanggal diterima di Lab : 08 Juni 2017 Tanggal pengujian : 08 Juni 2017 sampai 25 Juli 2017
Hasil Pengujian
NO. PARAMETER SATUAN HASIL METODE
KIMIA TANAH
1 pH
- H2O *) - 5,22 18-1/IK/TNH (Elektrometri)
2 C. Organik *) % 3,45 18-3/IK/TNH (Spektrofotometri)
3 N. Total *) % 0,79 18-6/IK/TNH (Spektrofotometri)
4 P2O5 bray *) ppm 2,36 18-2/IK/TNH (Spektrofotometri)
5 Susunan kation (NH4-Act)
- Ca me/100 gr 9,43 18-13/IK/TNH (Spektrofotometri)
- Mg me/100 gr 0,79 18-13/IK/TNH (Spektrofotometri)
- K me/100 gr 0,34 18-13/IK/TNH (Spektrofotometri)
- Na me/100 gr 3,53 18-13/IK/TNH (Spektrofotometri)
6 Kapasitas Tukar Kation me/100 gr 10,88 18-13/IK/TNH (Spektrofotometri)
7 Kemasaman
- Al – Tukar me/100 gr 7,19 18-9/IK/TNH (Titrimetri)
- H – Tukar me/100 gr 7,69 18-9/IK/TNH (Titrimetri)
8 Tekstur
- Pasir % 76,82 18-10/IK/TNH (Gravimetri)
- Debu % 11,52 18-10/IK/TNH (Gravimetri)
- Liat % 11,66 18-10/IK/TNH (Gravimetri)
9 Kejenuhan Basa % >100 18-13/IK/TNH
Keterangan : *) = Parameter terakreditasi oleh KAN No. LP-195-IDN • Kejenuhan Basa >100 terdapat kation-kation bebas disamping kation-kation dapat ditukar.
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 43 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh
digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium. • Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-44/TN/06/2017 Uraian contoh : Tanah (S-2) Koordinat : LS 01º 35’ 55‚16” BT 101º 08’ 33‚42" Tanggal diambil : 08 Juni 2017 Tanggal diterima di Lab : 08 Juni 2017 Tanggal pengujian : 08 Juni 2017 sampai 25 Juli 2017
Hasil Pengujian
NO. PARAMETER SATUAN HASIL METODE
KIMIA TANAH
1 pH
- H2O *) - 5,95 18-1/IK/TNH (Elektrometri)
2 C. Organik *) % 2,71 18-3/IK/TNH (Spektrofotometri)
3 N. Total *) % 0,46 18-6/IK/TNH (Spektrofotometri)
4 P2O5 bray *) ppm 1,30 18-2/IK/TNH (Spektrofotometri)
5 Susunan kation (NH4-Act)
- Ca me/100 gr 2,38 18-13/IK/TNH (Spektrofotometri)
- Mg me/100 gr 0,49 18-13/IK/TNH (Spektrofotometri)
- K me/100 gr 0,31 18-13/IK/TNH (Spektrofotometri)
- Na me/100 gr 3,58 18-13/IK/TNH (Spektrofotometri)
6 Kapasitas Tukar Kation me/100 gr 6,73 18-13/IK/TNH (Spektrofotometri)
7 Kemasaman
- Al – Tukar me/100 gr 1,00 18-9/IK/TNH (Titrimetri)
- H – Tukar me/100 gr 11,64 18-9/IK/TNH (Titrimetri)
8 Tekstur
- Pasir % 89,46 18-10/IK/TNH (Gravimetri)
- Debu % 7,81 18-10/IK/TNH (Gravimetri)
- Liat % 2,73 18-10/IK/TNH (Gravimetri)
9 Kejenuhan Basa % >100 18-13/IK/TNH
Keterangan : *) = Parameter terakreditasi oleh KAN No. LP-195-IDN • Kejenuhan Basa >100 terdapat kation-kation bebas disamping kation-kation dapat ditukar.
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 44 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh
digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium. • Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-45/TN/06/2017 Uraian contoh : Tanah (Area SQ 3B) Koordinat : LS 01º 38’ 03‚50” BT 101º 07’ 52‚70" Tanggal diambil : 08 Juni 2017 Tanggal diterima di Lab : 08 Juni 2017 Tanggal pengujian : 08 Juni 2017 sampai 25 Juli 2017
Hasil Pengujian
NO. PARAMETER SATUAN HASIL METODE
KIMIA TANAH
1 pH
- H2O *) - 4,39 18-1/IK/TNH (Elektrometri)
2 C. Organik *) % 2,82 18-3/IK/TNH (Spektrofotometri)
3 N. Total *) % 0,15 18-6/IK/TNH (Spektrofotometri)
4 P2O5 bray *) ppm 1,22 18-2/IK/TNH (Spektrofotometri)
5 Susunan kation (NH4-Act)
- Ca me/100 gr 2,41 18-13/IK/TNH (Spektrofotometri)
- Mg me/100 gr 0,30 18-13/IK/TNH (Spektrofotometri)
- K me/100 gr 0,46 18-13/IK/TNH (Spektrofotometri)
- Na me/100 gr 2,26 18-13/IK/TNH (Spektrofotometri)
6 Kapasitas Tukar Kation me/100 gr 8,51 18-13/IK/TNH (Spektrofotometri)
7 Kemasaman
- Al – Tukar me/100 gr 4,52 18-9/IK/TNH (Titrimetri)
- H – Tukar me/100 gr 3,84 18-9/IK/TNH (Titrimetri)
8 Tekstur
- Pasir % 69,14 18-10/IK/TNH (Gravimetri)
- Debu % 17,93 18-10/IK/TNH (Gravimetri)
- Liat % 12,93 18-10/IK/TNH (Gravimetri)
9 Kejenuhan Basa % 63,81 18-13/IK/TNH
Keterangan : *) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 45 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh
digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium. • Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-46/TN/06/2017 Uraian contoh : Tanah (Area SQ - 26) Koordinat : LS 01º 38’ 03‚50” BT 101º 07’ 47‚40" Tanggal diambil : 08 Juni 2017 Tanggal diterima di Lab : 08 Juni 2017 Tanggal pengujian : 08 Juni 2017 sampai 25 Juli 2017
Hasil Pengujian
NO. PARAMETER SATUAN HASIL METODE
KIMIA TANAH
1 pH
- H2O *) - 4,96 18-1/IK/TNH (Elektrometri)
2 C. Organik *) % 0,65 18-3/IK/TNH (Spektrofotometri)
3 N. Total *) % 1,96 18-6/IK/TNH (Spektrofotometri)
4 P2O5 bray *) ppm 0,80 18-2/IK/TNH (Spektrofotometri)
5 Susunan kation (NH4-Act)
- Ca me/100 gr 5,33 18-13/IK/TNH (Spektrofotometri)
- Mg me/100 gr 0,81 18-13/IK/TNH (Spektrofotometri)
- K me/100 gr 0,69 18-13/IK/TNH (Spektrofotometri)
- Na me/100 gr 0,03 18-13/IK/TNH (Spektrofotometri)
6 Kapasitas Tukar Kation me/100 gr 14,18 18-13/IK/TNH (Spektrofotometri)
7 Kemasaman
- Al – Tukar me/100 gr 3,22 18-9/IK/TNH (Titrimetri)
- H – Tukar me/100 gr 5,47 18-9/IK/TNH (Titrimetri)
8 Tekstur
- Pasir % 69,42 18-10/IK/TNH (Gravimetri)
- Debu % 19,37 18-10/IK/TNH (Gravimetri)
- Liat % 11,21 18-10/IK/TNH (Gravimetri)
9 Kejenuhan Basa % 48,38 18-13/IK/TNH
Keterangan : *) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 46 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh
digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium. • Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-47/TN/06/2017 Uraian contoh : Tanah (S1) Koordinat : LS 01º 37’ 38‚80” BT 101º 07’ 52‚70" Tanggal diambil : 08 Juni 2017 Tanggal diterima di Lab : 08 Juni 2017 Tanggal pengujian : 08 Juni 2017 sampai 25 Juli 2017
Hasil Pengujian
NO. PARAMETER SATUAN HASIL METODE
KIMIA TANAH
1 pH
- H2O *) - 4,24 18-1/IK/TNH (Elektrometri)
2 C. Organik *) % 0,37 18-3/IK/TNH (Spektrofotometri)
3 N. Total *) % 0,12 18-6/IK/TNH (Spektrofotometri)
4 P2O5 bray *) ppm 0,93 18-2/IK/TNH (Spektrofotometri)
5 Susunan kation (NH4-Act)
- Ca me/100 gr 2,04 18-13/IK/TNH (Spektrofotometri)
- Mg me/100 gr 0,25 18-13/IK/TNH (Spektrofotometri)
- K me/100 gr 0,38 18-13/IK/TNH (Spektrofotometri)
- Na me/100 gr 5,82 18-13/IK/TNH (Spektrofotometri)
6 Kapasitas Tukar Kation me/100 gr 9,96 18-13/IK/TNH (Spektrofotometri)
7 Kemasaman
- Al – Tukar me/100 gr 3,02 18-9/IK/TNH (Titrimetri)
- H – Tukar me/100 gr 7,70 18-9/IK/TNH (Titrimetri)
8 Tekstur
- Pasir % 78,13 18-10/IK/TNH (Gravimetri)
- Debu % 13,58 18-10/IK/TNH (Gravimetri)
- Liat % 8,29 18-10/IK/TNH (Gravimetri)
9 Kejenuhan Basa % 85,21 18-13/IK/TNH
Keterangan : *) = Parameter terakreditasi oleh KAN No. LP-195-IDN
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 47 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh
digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium. • Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
LAPORAN HASIL PENGUJIAN Nomor : 06269/LHP/VII/2017
Nama pelanggan : PT. SUPREME ENERGY MUARA LABOH Alamat : Kabupaten Solok Selatan, Provinsi Sumatera Barat No. identifikasi contoh : 05288-48/TN/06/2017 Uraian contoh : Tanah (S-4) Koordinat : LS 01º 38’ 00‚29” BT 101º 07’ 50‚24" Tanggal diambil : 08 Juni 2017 Tanggal diterima di Lab : 08 Juni 2017 Tanggal pengujian : 08 Juni 2017 sampai 25 Juli 2017
Hasil Pengujian
NO. PARAMETER SATUAN HASIL METODE
KIMIA TANAH
1 pH
- H2O *) - 5,77 18-1/IK/TNH (Elektrometri)
2 C. Organik *) % 0,59 18-3/IK/TNH (Spektrofotometri)
3 N. Total *) % 0,12 18-6/IK/TNH (Spektrofotometri)
4 P2O5 bray *) ppm 13,69 18-2/IK/TNH (Spektrofotometri)
5 Susunan kation (NH4-Act)
- Ca me/100 gr 3,96 18-13/IK/TNH (Spektrofotometri)
- Mg me/100 gr 0,55 18-13/IK/TNH (Spektrofotometri)
- K me/100 gr 0,51 18-13/IK/TNH (Spektrofotometri)
- Na me/100 gr 0,18 18-13/IK/TNH (Spektrofotometri)
6 Kapasitas Tukar Kation me/100 gr 3,59 18-13/IK/TNH (Spektrofotometri)
7 Kemasaman
- Al – Tukar me/100 gr <0,1 18-9/IK/TNH (Titrimetri)
- H – Tukar me/100 gr 1,21 18-9/IK/TNH (Titrimetri)
8 Tekstur
- Pasir % 7,31 18-10/IK/TNH (Gravimetri)
- Debu % 74,14 18-10/IK/TNH (Gravimetri)
- Liat % 18,55 18-10/IK/TNH (Gravimetri)
9 Kejenuhan Basa % >100 18-13/IK/TNH
Keterangan : *) = Parameter terakreditasi oleh KAN No. LP-195-IDN • Kejenuhan Basa >100 terdapat kation-kation bebas disamping kation-kation dapat ditukar.
Jakarta, 25 Juli 2017 PT. UNILAB PERDANA
Khairun Nisa Plt. Kadiv. Mutu
Halaman 48 dari 51
• Hasil yang ditampilkan hanya berhubungan dengan contoh yang diuji dan laporan hasil pengujian tidak boleh
digandakan kecuali seluruhnya tanpa persetujuan tertulis dari laboratorium. • Pengaduan terhadap laporan hasil pengujian tidak dilayani setelah 30 hari dari waktu penerbitan laporan hasil pengujian
•
Attachment 5
Attachment 6
Site verification of Hazmat Storage by DPKPLH
8 June 2017
Internal Use Only
Purpose: Site Verification of Hazmat Storage by DPKPLH Date: 8 June 2017
Prepared by Dwi Rahayu Doc Ref:
Place: Yard I
Name Organization
Present: DR, FR, AH Zainal, Yuli, Elsa, Novi, Mori, Resti, Endri
SEML DPKPLH
Apologies:
Distribution:
Item Action By/Date
1 The result of DPKPLH visit on Hazmat Storage Building: - Location for Hazmat Storage has been approved, because it was
far from community (still was in SEML area). - Building should be protected from rain. - Next verification will be held after 80% completion of the building
Attachments:
Prepared by ______Dwi Rahayu_____ 8 June 2017
(Env. Engineer) Date
Internal Use Only 2
DOCUMENTATION
Internal Use Only 3
ATTENDANCE LIST