8
D-37660-2015 MSHA*-Approved Gas Detection Solutions *Mine Safety and Health Administration

MSHA*-Approved Gas Detection Solutions...PRODUCT CATALOG FOR MSHA GAS DETECTION | 05 D-59025-2012 DRÄGER X-AM 2500 Dräger’s X-am® 2500 accurately detects O 2, CO, NO 2, SO 2,

  • Upload
    others

  • View
    12

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MSHA*-Approved Gas Detection Solutions...PRODUCT CATALOG FOR MSHA GAS DETECTION | 05 D-59025-2012 DRÄGER X-AM 2500 Dräger’s X-am® 2500 accurately detects O 2, CO, NO 2, SO 2,

D-3

7660

-201

5

MSHA*-Approved Gas Detection Solutions

*Mine Safety and Health Administration

Page 2: MSHA*-Approved Gas Detection Solutions...PRODUCT CATALOG FOR MSHA GAS DETECTION | 05 D-59025-2012 DRÄGER X-AM 2500 Dräger’s X-am® 2500 accurately detects O 2, CO, NO 2, SO 2,

02 | PRODUCT CATALOG FOR MSHA GAS DETECTION

D-3

7661

-201

5

Page 3: MSHA*-Approved Gas Detection Solutions...PRODUCT CATALOG FOR MSHA GAS DETECTION | 05 D-59025-2012 DRÄGER X-AM 2500 Dräger’s X-am® 2500 accurately detects O 2, CO, NO 2, SO 2,

| 03PRODUCT CATALOG FOR MSHA GAS DETECTION

The Drägerman always stands guardMines represent one of the world’s most dangerous work environments. For generations, miners have relied on Dräger for quality products to protect their lives. The technologies offered by Dräger’s breathing apparatus have paved the way for an entirely new profession: mine rescue. All over the world, mine rescuers are called “Drägermen”—even today.

D-3

7662

-201

5

Now MSHA-approvedDräger’s mine operations portfolio encompasses an integrated safety concept that improves mine safety and includes a comprehensive line of MSHA-approved products that detect hazardous levels of methane, oxygen deficiency, and toxic gases. Whether you need personal area monitors to continually evaluate oxygen levels or take spot measurements for combustible gases, Dräger’s single and multi-gas monitors are fast, accurate, and reliable.

Page 4: MSHA*-Approved Gas Detection Solutions...PRODUCT CATALOG FOR MSHA GAS DETECTION | 05 D-59025-2012 DRÄGER X-AM 2500 Dräger’s X-am® 2500 accurately detects O 2, CO, NO 2, SO 2,

04 | PRODUCT CATALOG FOR MSHA GAS DETECTION

Dräger Pac Series Gas DetectorsThe Dräger Pac® series is composed of fast, accurate, reliable and easy-to-use personal single gas detectors. The devices are extremely robust, featuring clear warning signals and language-free displays. Their cutting-edge sensor technology delivers reliable results every time.

The impact-resistant and chemical-resistant rubber housing meets the requirements of IP68, so the devices can be exposed to spray water. A stable and rotating alligator clip ensures secure fastening to your clothing.

Equipped with the latest Dräger XXS miniature sensor technology, the Dräger Pac series represents excellence in the field of gas detection. The devices are extremely durable, highly responsive, and have a variety of features for capturing events, including the ability to adjust the frequency of functional tests and calibrations individually.

D

-165

22-2

009

DRÄGER PAC 7000 – Measures carbon dioxide, sulfur dioxide, chlorine, hydrogen cyanide, ammonia,nitrogen dioxide, nitric oxide, phosphine, carbon monoxide, hydrogen sulfide and oxygen or organic vapors

– Warranty of 2 years, optional 5 year warranty for the H2S, O2, and CO devices

– Estimated sensor service life of 5–8 years – Easy to replace batteries and sensors – Service life of the device is not limited – Replaceable dust and water filters – Data logger for storage of gas concentrations and events withdate and time (120 hours at 1 record per minute)

– Configurable TWA and STEL alarms – Recording maximum concentrations – Rapid functional tests on site – Automatic function test option

Page 5: MSHA*-Approved Gas Detection Solutions...PRODUCT CATALOG FOR MSHA GAS DETECTION | 05 D-59025-2012 DRÄGER X-AM 2500 Dräger’s X-am® 2500 accurately detects O 2, CO, NO 2, SO 2,

| 05PRODUCT CATALOG FOR MSHA GAS DETECTION

D-5

9025

-201

2

DRÄGER X-AM 2500Dräger’s X-am® 2500 accurately detects O2, CO, NO2, SO2, CH4, and H2S and combines reliable sensor technology with long battery life and intuitive operation in an instrument that defines safety.

The X-am 2500 is compatible with Dräger’s X-dock® testing and calibration station. X-dock is Dräger’s new solution for efficient maintenance and comprehensive equipment management. Used for functional testing and complete documentation, X-dock can complete bump tests in as little as 15 seconds with more than 40% less gas consumption than competitive instruments. The X-am 2500 is also compatible with the Dräger Bump Test Station.

D-5

9025

-201

2

DRÄGER X-AM 5000The smallest gas detection instrument for up to five gases, the Dräger X-am 5000 belongs to a new generation of detectors developed especially for personal monitoring. It reliably measures oxygen, organic vapors, combustible gases, and harmful concentrations of CO, H2S, CO2, Cl2, HCN, NH3, NO2, PH3, SO2, and many others with high sensitivity to keep you safe.

The Dräger X-am 5000 is tough. It’s dust-resistant according to IP67, and remains fully functional even after falling into water. The integrated rubber protection and shock-proof sensors give additional resistance to impact and vibration.

Moreover, the Dräger X-am 5000 is insensitive to electromagnetic interference. This means you can count on it—even in the harshest conditions.

Page 6: MSHA*-Approved Gas Detection Solutions...PRODUCT CATALOG FOR MSHA GAS DETECTION | 05 D-59025-2012 DRÄGER X-AM 2500 Dräger’s X-am® 2500 accurately detects O 2, CO, NO 2, SO 2,

06 | PRODUCT CATALOG FOR MSHA GAS DETECTION

D-4

7894

-201

2

DRÄGER X-DOCK 5300/6300/6600Automatic bump tests, calibration, reduced test gas consumption, short testing times and comprehensive documentation come standard in the X-dock to let you work smarter and safer.

Testing is as simple as inserting your Dräger gas detection instrument and closing the lid. The X-dock immediately detects all sensor combinations and automatically tests and adjusts when all of the required test gases are connected. All generated data is documented in the database.

Ensure MSHA Calibration ComplianceAll Dräger MSHA-approved gas monitors feature adjustable bump test and calibration intervals that alert you when a bump test or calibration is required. These intervals can be set for each instrument and are automatically recognized by the X-dock during a routine bump test. All calibration data is stored, helping to ensure that all monitors in use are calibrated and documented. 

Reduced test gas means reduced costsWith a reduced gas flow (300 mL/min instead of 500 mL/min = 40% decrease) per module, you save money on test gases. Short testing times also reduce overall maintenance requirements. Dräger’s patent-pending innovative valve only needs one pump, which means less wear on parts for you. The valves automatically switch the test gases and the fresh air source as well.

Time is money, you save both with X-dockUp to 10 modules can be connected to the X-dock, allowing you to test gas detection instruments simultaneously or individually. The automatic bump test also saves time, because the test takes as little as 15 seconds. All Dräger test gas cylinders are already stored in the database—just enter the part number to automatically fill the fields required for the gas configuration, eliminating the need for manual data entry.

Additional X-dock benefits – Touchscreen operation at the master controller station – Up to three configurable test routines – Automatic permeability tests – Automatic tests of all alarm elements (acoustic, visual and vibration alarms) – Optional charging function for X-am 1/2/5x00 – Easy-to-replace seal cartridge – 12V operation (e.g., in vehicles) available – Can be expanded with up to 10 modules (X-dock 6300/6600) – Sensor performance testing

Page 7: MSHA*-Approved Gas Detection Solutions...PRODUCT CATALOG FOR MSHA GAS DETECTION | 05 D-59025-2012 DRÄGER X-AM 2500 Dräger’s X-am® 2500 accurately detects O 2, CO, NO 2, SO 2,

| 07PRODUCT CATALOG FOR MSHA GAS DETECTION

DRÄGER X-DOCK MANAGER SOFTWARE Companion software for X-dock provides:

– An overview page – Gas exposure in specific areas – Number of executed tests – Device availability – Overview of created/sent reports – Templates for regular reports – An issue and return function – Monitoring of stations in the network – Overview of devices

D-5

7160

-201

2

ORDERING INFORMATION

MSHA-APPROVED CALIBRATION

Dräger X-dock® Part No.

Dräger X-dock® 5300 for Dräger X-am® 125 83 21 880Set consisting of one master (3 gases) with power supply and one instrument module for the instruments Dräger X-am® 125

Dräger X-dock® 5300 for Dräger Pac® 83 21 881Set consisting of one master (3 gases) with power supply and one instrument module for the instruments Dräger Pac 3500/5500 and Dräger Pac 7000

Dräger X-dock® Module for Dräger X-am® 125 83 21 890Cradle module for one instrument if the Dräger X-am 125 series

Dräger X-dock® Module for Dräger X-am® 125+ 83 21 891Cradle module for one instrument if the Dräger X-am 125 series with and additional charging function

Dräger X-dock® Module for Dräger Pac® 83 21 892

Cradle module for one instrument if the Dräger Pac series

Dräger X-dock® 6300 Master 83 21 900With 3 test gas connections plus fresh air. At least 1 module must be ordered, extendable to max. 10 modules

Dräger X-dock® 6600 Master 83 21 901With 6 test gas connections plus fresh air. At least 1 module must be ordered, extendable to max. 10 modules MSHA-APPROVED SINGLE GAS MONITORS

Dräger Pac® Part No.

Dräger Pac® 7000, CO, 0–1,999 ppm, 1 ppm resolution, MSHA A1 35 ppm/A2 50 ppm 45 42 199

Dräger Pac® 7000, O2, 0–25% Vol., 0.1% Vol. resolution, MSHA A1 19.5% Vol./A2 23.5% Vol 45 42 198

Dräger Pac® 7000, H2S, 0–100 ppm, 1 ppm resolution, MSHA A1 10 ppm/A2 20 ppm 45 42 197

Page 8: MSHA*-Approved Gas Detection Solutions...PRODUCT CATALOG FOR MSHA GAS DETECTION | 05 D-59025-2012 DRÄGER X-AM 2500 Dräger’s X-am® 2500 accurately detects O 2, CO, NO 2, SO 2,

08 | PRODUCT CATALOG FOR MSHA GAS DETECTION

90 7

2 45

1 |

16.12

-4 |

HQ

| P

P |

Subj

ect t

o m

odifi

catio

ns |

© 2

016

Drä

gerw

erk

AG &

Co.

KG

aA

CORPORATE HEADQUARTERSDrägerwerk AG & Co. KGaAMoislinger Allee 53–5523558 Lübeck, Germany

www.draeger.com

Customer Service:USA +1 800-4DRAGER (+1 800-437-2437)

CANADA +1 877-DRAGER1 (+1 877-372-4371)

Technical Service:USA +1 800-4DRAGER(+1 800-437-2437)

Locate your Regional Sales Representative at: www.draeger.com/contact

ORDERING INFORMATION

MSHA-APPROVED MULTI GAS MONITORS

Dräger X-am® 2500 Part No.Dräger X-am® 2500, Ex, O2, CO, H2S Alk Batt, MSHA 45 42 294Dräger X-am® 2500, Ex, O2, CO, H2S NiMH Batt, MSHA 45 42 295Dräger X-am® 2500, Ex, O2, H2S, Alk Batt, MSHA 45 42 296Dräger X-am® 2500, Ex, O2, H2S, NiMH Batt, MSHA 45 42 297Dräger X-am® 2500, Ex, O2, CO, Alk Batt, MSHA 45 42 298Dräger X-am® 2500, Ex, O2, CO, NiMH Batt, MSHA 45 42 299Dräger X-am® 2500, Ex, NiMH Batt, MSHA 45 42 301Dräger X-am® 2500, Ex, O2, CO, NiMH, MSHA,QTY 6, no chrgs 45 42 305Dräger X-am® 2500, Ex, O2, CO, NiMH, MSHA, w/ charger 45 42 307Dräger X-am® 2500, O2, SO2, NiMH, w/ charger 45 42 309Dräger X-am® 2500, CH4, O2, CO, NO2, MSHA, w/ charger 45 42 311

Dräger X-am® 5000 Part No.Dräger X-am® 5000, CH4, O2, CO, NO2, NiMH Batt Kit 45 43 923No additional sensors can be selected with this configurationDräger X-am® 5000, CH4, NiMH Batt Kit 45 43 925Choose up to 3 additional electrochemical sensors from the Installed Sensor section belowDräger X-am® 5000, CH4, O2, NiMH Batt Kit 45 43 926Choose up to 2 additional electrochemical sensors from the Installed Sensor section belowDräger X-am® 5000, CH4, O2, CO NiMH Batt Kit 45 43 927Choose 1 additional electrochemical sensor from Installed Sensor section below Dräger X-am® 5000, CH4, O2, H2S NiMH Batt Kit 45 43 928Choose 1 additional electrochemical sensor from Installed Sensor section below Dräger X-am® 5000, CH4, O2, CO2, H2S NiMH Batt Kit 45 43 929No additional sensors can be selected with this configurationDräger X-am® 5000, CH4, O2, Dual CO/H2S NiMH Batt Kit 45 43 930Choose 1 additional electrochemical sensor from Installed Sensor section below Dräger X-am® 5000, CH4, O2, CO, CO-HC NiMH Batt Kit 45 43 931No additional sensors can be selected with this configuration Dräger X-am® 5000, CH4, O2, CO, CO-HC, NO2 NiMH Batt Kit 45 43 933No additional sensors can be selected with this configurationDräger X-am® 5000 HC, CH4, O2, w/ NiMH & CHRG, MSHA 45 43 978Dräger X-am® 5000 HC, CH4, w/ NiMH & CHRG, MSHA 45 43 979Dräger X-am® 5000 HC, CH4, w/ NiMH & CHRG, PUMP, MSHA 45 43 980Dräger X-am® 5000 HC, CH4, O2, w/ NiMH & CHRG, PUMP, MSHA 45 43 981KIT, MSHA, PX2 PUMP w/ adapter for Dräger X-am® 125 45 43 982MSHA PUMP POUCH 45 43 985

Not all products, features, or services are for sale in all countries. Mentioned Trademarks are only registered in certain countries and not necessarily in the country in which this material is released. Go to www.draeger.com/trademarks to find the current status.