  • 8/17/2019 MSAD Installation Ed1.1 En

    1/49

    G D C - 0 0 2 / 5 8

  • 8/17/2019 MSAD Installation Ed1.1 En

    2/49

    INTRACOM TELECOM 19.7 km Markopoulou Ave., Peania, Athens, GR 19002

    T +30 210 667 1000, F +30 210 667 1001http://www.intracom-telecom.com

    The information contained in this document is subject to change without prior notice.

    INTRACOM S.A. TELECOM SOLUTIONS, 2011. All rights reserved.

    All copyright, intellectual and industrial rights in this document and in the technical knowledge it containsare owned by INTRACOM S.A. TELECOM SOLUTIONS and/or their respective owners.

    This document is made available to the end users only for their internal use.No part of this document nor any data herein may be published, disclosed, copied, reproduced,

    redistributed by any form or means, electronically or mechanically, or used for any other purposewhatsoever without the prior written approval of INTRACOM S.A. TELECOM SOLUTIONS.Information as well as drawings and specifications contained in this document are subject to changewithout prior notice.

    All trademarks and copyrights mentioned herein are the property of INTRACOM S.A. TELECOMSOLUTIONS and/or their respective owners.

    Any rights not expressly granted herein are reserved.

    Printed in Greece.

  • 8/17/2019 MSAD Installation Ed1.1 En

    3/49

    Document Revision History WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    Document Revision History

    Revisions · Previous Edition: 1.0·

    Current Edition: 1.1

    Reasons of change

    The following table lists the main changes 1 effected in relation to the previousedition of the document:

    Reason of change

    · Attenuation limitation of IF cable has been changed (sites prerequisites).

    1 Please refer to the Releases Notes of the product for details on supported features.

  • 8/17/2019 MSAD Installation Ed1.1 En

    4/49

  • 8/17/2019 MSAD Installation Ed1.1 En

    5/49

    Table of Contents WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    -I-

    Table of Contents

    1 Introduction ....................................................................................................................... 1 About this Document........... ......... ......... ......... ......... ........... ......... ......... ......... ......... ......... .... 1 About MSADe ........ .......... ......... ......... ......... .......... ......... ......... .......... ......... ......... ......... ....... 2Equipment Disposal ............................................................................................................ 3Safety Precautions..............................................................................................................4

    2 Required Tools and Materials........................................................................................... 6Tools...................................................................................................................................6Material List......................................................................................................................... 8

    3 Before starting the Installation....................................................................................... 11Site Prerequisites.............................................................................................................. 11Cabling Overview.............................................................................................................. 14Preparing the IF Cable at the MSADe Side....................................................................... 15Preparing the Power Cable(s) (for MSADe DC Models) ......... .......... ........ ........... ........ ...... 21

    4 Mechanical Installation ................................................................................................... 22

    5 Cabling Instructions........................................................................................................ 24IF Cable Connection ......................................................................................................... 24IF Cable Lightning Arrestor Connection.............................................................................26I / O Alarms Connection.................................................................................................... 28120 Ω E1 Tributary Channels Connection ......................................................................... 3175 Ω E1 Tributary Channels Connection ........................................................................... 32FE Connection ..................................................................................................................32Management Connection ..................................................................................................33Local DC Power Source Connection (for MSADe DC Models) ........ .......... .......... ........ ...... 34Local AC Power Source Connection (for MSADe AC Models)............ .......... ......... ......... ... 36

    Appendix A – Receptacles Pin out........................................................................................37

  • 8/17/2019 MSAD Installation Ed1.1 En

    6/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    Table of Contents

    -II-

    (Page intentionally left blank)

  • 8/17/2019 MSAD Installation Ed1.1 En

    7/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    1

    1 Introduction

    About this Document

    Documentobjective

    This document provides information concerning the installation and cabling of WiBAS MSADe.

    Targetaudience

    This document is addressed to technicians with knowledge and skillsconcerning the installation and cabling of indoor equipment.

    Documentconventions

    This document applies the following conventions:

    This symbol means DANGER . The purpose of this symbol is towarn you that any wrong action can cause bodily injury or evendeath.

    This symbol means CAUTION . The purpose of this symbol is toprevent you from performing an action that might result in damageof the equipment.

    NOTE A note calls your attention to important supplementary information.

  • 8/17/2019 MSAD Installation Ed1.1 En

    8/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    2

    About MSADe

    Description The MSADe is the indoor unit of the WiBAS Terminal Station (WiBAS TS)located at the customer’s premises. It is an advanced network device that

    can perfectly meet all access requirements at a service location for a largenumber of different applications.The role of MSADe is to control the TRS (Terminal Station Radio System),implement the baseband modem, and provide the user network interfaces.With the support of highly developed interworking mechanisms andsophisticated QoS features, it stands for a comprehensive gateway,addressing the needs of demanding high-end customers.The following schematic depicts the components and the end-to-end networkinterconnection for a WiBAS system:

    The MSADe is a 1 RU ETSI 19” subrack suitable for desktop or rackmounting.The case is environmentally and temperature hardened and is made of pressure die cast aluminum.No movable mechanical parts (i.e. fans) are employed for cooling, as theyturn out to be unreliable and prone to failures. Instead, passive cooling isemployed, a technique that also provides outstanding mechanical reliability.

    All connection receptacles are accessible from the front panel.The following photos show two models of the MSADe subrack:

    MSADe-4ETH-8E1-DC (Ethernet plus E1)

    MSADe-4ETH-DC (Ethernet only)

    Continued on next page

  • 8/17/2019 MSAD Installation Ed1.1 En

    9/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    3

    About MSADe, Continued

    MSADe models The following table lists the available MSADe models. All MSADe models areavailable with AC or DC-input power supply.

    Number of I/FsPhoto MSADe Model

    ETH E1 / G703

    MSADe-4ETH-DC(with DC-input) 4 -

    MSADe-4ETH-8E1-DC(with DC-input) 4 8

    MSADe-4ETH-AC

    (with AC-input)4 -

    MSADe-4ETH-8E1-AC(with AC-input) 4 8

    Equipment Disposal

    Applicable through the European Union and other European countries

    with separate waste collection systems

    This symbol, found on this product and any of its parts or on its operatinginstructions or on its packaging, indicates that electrical and electronicequipment may not be disposed of as unsorted municipal waste. Instead, thisproduct should be handed over to applicable collection points for the recyclingof electrical and electronic equipment.By ensuring the correct disposal of this product, you will help prevent potentialnegative consequences to the environment and human health, which couldotherwise be caused by inappropriate disposal of this product.By recycling, reusing and other forms of recovery of old electrical andelectronic equipment you are making an important contribution to theconservation of natural resources and to the protection of the environment.For more information about the recycling of this product, please contact your local municipal authorities, municipal waste disposal service or the store whereyou purchased this product.

  • 8/17/2019 MSAD Installation Ed1.1 En

    10/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    4

    Safety Precautions

    PROPER GROUNDING

    Never power up the indoor equipment not yet connected to a proper grounding system.

    There is risk of equipment failure and/or electrical shock.

    Ensure that the indoor grounding system measures a path resistance lessthan 4 Ω .

    INDOOR EQUIPMENT PROPER SWITCHING ON / OFF(only for the DC models)

    Never connect or disconnect the power supply cable(s) to or from theindoor equipment when the local dc power supply source is on.

    There is risk of equipment failure.

    Ensure the local dc power supply source is off and then connect or disconnect the power supply cable(s) to or from the indoor equipment.

    PROTECTION AGAINST LIGHTNING

    Do not leave the IF cable coming from the Outdoor Unit withoutadequate lightning protection in sites with increased lightningpossibility. (1)

    There is risk of equipment failure and/or electrical shock.

    Ensure that the IF cable coming from the Outdoor Unit is properly groundedwith special grounding kits (outdoor installation) and lightning arrestor (indoor installation) provided by the Manufacturer.(1) Sites in which the ODU installation place completes one of the following conditions:

    · It is at a high altitude (i.e. on a hill or mountain).· It is the highest point from all the adjacent installed at a perimetric area.

    · It is characterized by frequent occurrence of lightning.

    Continued on next page

  • 8/17/2019 MSAD Installation Ed1.1 En

    11/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    5

    Safety Precautions, Continued

    ESD PROTECTION

    Always use proper antistatic protection (i.e. grounding bracelet,antistatic bags, etc.) when handling the system cards.

    Parts bearing the ESD sign (see left) have ESD sensitive exposedcomponents.

  • 8/17/2019 MSAD Installation Ed1.1 En

    12/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    6

    2 Required Tools and Materials

    Tools

    Installationtools

    Photo Description· PH-1

    · PH-3

    AZ-2,5

    Blade

    Set of U-type wrenches

    Crimping tool for 4 mm 2 cable

    Torque wrench 4,4 Nm,

    HEX 11 mm

    Continued on next page

  • 8/17/2019 MSAD Installation Ed1.1 En

    13/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    7

    Tools, Continued

    RJ-11 cable

    terminationtools Tool Description

    Termination tool

    Stripping tool

    Crimping tool

  • 8/17/2019 MSAD Installation Ed1.1 En

    14/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    8

    Material List

    The following table provides all the material required for the installation and

    cabling of the unit. Some items are optional and may have not been ordered.

    MSADe Packaging

    Item Photo Description Qtyper Site Comments

    1 MSADe 1 Different models areavailable.

    2Set

    of Brackets & Screwsfor Chassis Mounting

    1

    3Four Adhesive Feet

    for MSADedesktop positioning

    1

    4 Power SupplyConnectors 1 or 2Included in the MSADeDC models packaging.

    5 IEC Power Cord 1 Included in the MSADe AC models packaging.

    6 Grounding Cable 1

    Grounding cable,factory pre-terminatedto ring terminals(at both ends).

    Continued on next page

  • 8/17/2019 MSAD Installation Ed1.1 En

    15/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    9

    Material List, Continued

    MSADe Installation Kit

    Item Photo Description Qtyper Site Comments

    7 Power Cables10 m red

    10 m blue

    Only for MSADe DC models.

    Two power cables(red / blue),1,5 mm 2 each, stranded.

    8 Cable Ties 20 white20 black

    Cable ties (two colours;white for indoor use,black for outdoor use).

    9 Grounding Screw 1

    The screw and nutincluded are for connection of MSADegrounding cable to therack grounding terminal.

    10 Grounding Ring

    Terminals1

    Spare ring terminals for grounding cabletermination.

    Continued on next page

  • 8/17/2019 MSAD Installation Ed1.1 En

    16/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    10

    Material List, Continued

    MSADe Accessories & Cables

    Item Photo Description Qtyper Site Comments

    11 Balun 75 / 120 Adapter

    Up to 8

    Optional.RJ-45 femaleto 2 x BNC female.Converts a balanced 120 Ω E1interface provided by theMSADe to unbalanced 75 Ω E1interface provided by the BNCpair.(RJ-45 to RJ-45 cable isrequired for Balun connection tothe MSADe, see item 12 below.)

    12InterconnectionCable,

    MSADe E1 i/f to Balun

    (1)

    2 pairs x AWG26 (solid)2 x RJ-45, 8-pin, Male(shielded).

    Available lengths:0,5 m, 1 m, 3 m & 5 m.

    13 Angle Adapter 1

    Optional.F-type male to F-type femaleR/A adaptor for IF cableconnection.

    14 Lightning Arrestor for IF Cable 1

    Optional.75 Ω lightning arrestor,for bi-directional protection,

    up to 10 kA surge protection.F-type female (bulk-head)to F-type female.Mandatory for sites withincreased lightning

    possibility.

    15 Alarms Cable 1

    Optional.15 x AWG28DB15, Male to DB9, Female(for Serial Console connection)and to open end(for input / output alarms

    connection).2,1 m length DB15 to DB92,5 m length DB15 to open end.

    16 IF TerminationConnector 1

    F-Type connector, male,weatherproof,for RG-11 coaxial cabletermination (MSADe side).

    (1) Quantity depends on the baluns number.

  • 8/17/2019 MSAD Installation Ed1.1 En

    17/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    11

    3 Before starting the Installation

    Site Prerequisites

    Introduction This section discusses all the prerequisites prior to installing the indoor unitof the Terminal Station.

    Siteinformation Premises information

    · Site details (address, contact persons, etc.)· Site access and storage information (means of transport, equipment

    storage and lifting information, etc.)·

    Site location mapsNetwork planning – Site survey information· Geographical positions of TS and BS site· Height of all buildings at the installation premises· Rooftop information (height, status, access, dimensions, layout, etc.)· Information about pre-existing indoor/ outdoor equipment· Available mounting space (on the buildings’ roofs) to reserve for the

    installation of the outdoor equipment

    Site-specific information· Mechanical specifications of mast/ tower (type, dimensions/ diameter,

    material, exterior finishing, etc.)· Location of appropriate grounding points· Location of appropriate power supply distribution points· Location of cable conduits available for routing the coaxial cable

    (interconnecting the indoor with the outdoor equipment)· Location of the network port distributors· Total length of the IF cable required to interconnect the indoor with the

    outdoor equipment

    Network portdistributors

    Regarding the network ports (inclusive of Ethernet and E1) provided with theindoor equipment, suitable network port distributors should be available.The exact location of the network port distributors, as well as the networkports to reserve, should be known prior to installing the indoor equipment.

    Also, all the reserved ports on the network port distributors should bequalified and tested before realizing the network connections with the indoor equipment.

    Continued on next page

  • 8/17/2019 MSAD Installation Ed1.1 En

    18/49

  • 8/17/2019 MSAD Installation Ed1.1 En

    19/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    13

    Site Prerequisites, Continued

    Distributorslightning

    protection

    The network port distributors (optical distributors excluded) and the power supply distributors should be equipped with the appropriate gas arresters, toprovide protection against lightning conditions.Such conditions may induce voltage peaks on the cables, and thus disturbthe operation of the indoor equipment. For this purpose, all electricaldistributors should be connected to the local grounding system to allow theinstalled gas arresters to operate.

    Lightningprotection atspecific sites

    In sites with increased lightning possibility (1) , adequate lightning protectionshould be used for the IF cable coming from the Outdoor Unit. Morespecifically, the IF cable should be properly grounded with special groundingkits installed along the cable (outdoor installation) and a lightning arrestor installed anywhere along the IF cable (indoor installation). The Manufacturer can provide the grounding kits and lightning arrestor on customer’s request.(1) Sites in which the ODU installation place completes one of the following conditions:

    · It is at a high altitude (i.e. on a hill or mountain).· It is the highest point from all the adjacent installed at a perimetric area.

    · It is characterized by frequent occurrence of lightning.

    Preparation of the installation

    premises

    Access to the installation premises must be facilitated during the installationperiod.

    Entrances must be large enough to enable the easy transportation of the newequipment.The floor must be level, smooth and able to bear the load of the equipment.

    The roof must be engineered to bear the weight of the service personnel andthe outdoor equipment.

    Safety The indoor equipment premises should be of restricted access.Only trained, authorized personnel should have access to the installedequipment.

    Appropriate labeling should exist at points with high risk of contact withhazardous voltage.

    A list with emergency phone numbers (e.g. medical assistance numbers)should be hung at easy-to-view positions.

    Also, recommended are for safety purposes, a fire detection system and fireextinguishers (installed at easy-to-access points) inside the installationpremises.

  • 8/17/2019 MSAD Installation Ed1.1 En

    20/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    14

    Cabling Overview

    Find below a cabling overview schematic for each MSADe model.

    MSADe-4ETH-DC

    MSADe-4ETH-8E1-DC

    MSADe-4ETH-AC

    MSADe-4ETH-8E1-AC

  • 8/17/2019 MSAD Installation Ed1.1 En

    21/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    15

    Preparing the IF Cable at the MSADe Side

    Introduction This section concerns the termination of the coaxial 75 Ω cable (RG-11) at

    the MSADe side. This cable will be used for interconnecting the MSADe withthe TRB.

    Tools · Termination tool· Stripping tool· Crimping tool

    Accessories Item 16 from Material List on page 10 and RJ-11 coaxial cable.

    Procedure To terminate the RG-11 coaxial cable, proceed as follows:

    Step Action

    1 Insert the coaxial cable into the stripping tool as shown below(lettering on tool face toward the incoming cable):

    2 Cable’s end should protrude 1 mm (approx.) out of the tool:

    Continued on next page

    1 mm

  • 8/17/2019 MSAD Installation Ed1.1 En

    22/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    16

    Preparing the IF Cable at the MSADe Side, Continued

    Procedure

    (continued) Step Action3 With your finger, rotate the tool around cable end, clockwise and

    several times. Stop when you feel that resistance during rotationis weakened.

    4 Pull out the tool as shown below:

    5 Outer sheath, braid, aluminum foil and inner insulation have nowbeen removed. Cable end is ready to be terminated:

    Continued on next page

  • 8/17/2019 MSAD Installation Ed1.1 En

    23/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    17

    Preparing the IF Cable at the MSADe Side, Continued

    Procedure

    (continued) Step Action6 Flare and evenly fold braid back and over the cable sheath.

    DO NOT remove the exposed aluminum foil.

    7 Tighten the F-type connector (for RG-11 coaxial cable) into themating head of the RG-11 termination tool.

    8 Spot the see-through hole on the tool. It will be used for checkingproper termination later.

    Continued on next page

  • 8/17/2019 MSAD Installation Ed1.1 En

    24/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    18

    Preparing the IF Cable at the MSADe Side, Continued

    Procedure

    (continued) Step Action9 Insert and push the end of the coaxial cable into the F-type

    connector.

    10 Hold the tool and cable as shown below.Rotate the tool head several turns, and simultaneously push thecable into the tool.

    Continued on next page

  • 8/17/2019 MSAD Installation Ed1.1 En

    25/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    19

    Preparing the IF Cable at the MSADe Side, Continued

    Procedure

    (continued) Step Action11 Stop rotating when the connector’s center pin is visible from the

    see-through hole:

    12 Unscrew and remove the connector from the tool. Theconnector’s center pin is now clearly visible from the side:

    13 Open the handles of the RG-11 crimping tool and select the bigRG-11 head (this should face upward):

    Continued on next page

  • 8/17/2019 MSAD Installation Ed1.1 En

    26/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    20

    Preparing the IF Cable at the MSADe Side, Continued

    Procedure

    (continued) Step Action14 Install the F-type connector into the tool’s head. Then, fully close

    the tool’s handles:

    15 Cable termination is now complete. The connector should looklike below:

    End of procedure.

  • 8/17/2019 MSAD Installation Ed1.1 En

    27/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    21

    Preparing the Power Cable(s) (for MSADe DC Models)

    Introduction This paragraph shows you how to terminate the power cable(s) in case youhave the DC model of MSADe.

    Tools · Blade· AZ-2,5 screwdriver

    Accessories Items 4, 7 and 8 from Material List on page 8.

    Preparing thepower cable(s)

    To prepare the power cable(s), follow the steps below:

    Step Action

    1 Prepare the one end (facing the MSADe) of each cable as shownbelow.a. Strip insulation from each cable for 8 mm.b. Twist strands well to facilitate their insertion into the connector.

    8 mm

    2 Insert the bare ends of the cable well into the correspondingpositions of the connector, as shown below (top view):

    Blue wire (b) to pin 1 (-Vin).Red wire (c) to pin 2 (+Vin / GND).

    (+Vin/GND)

    (-Vin)

    1

    2

    c

    b

    2

    1

    3 Tighten the two screws on top of the connector to secure strands.

    NOTE The two screws, securing the wire strands into theconnector, are well isolated each other – no danger for accidental short circuit.

    4 Use the white cable ties along the two cables to reserve themtogether.

    5 Repeat steps 1 to 4 for the other pair of cables, if needed.

  • 8/17/2019 MSAD Installation Ed1.1 En

    28/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    22

    4 Mechanical Installation

    Only trained and qualified personnel should install or replace this

    equipment.

    Prerequisites Ensure that the installation premises is equipped with a reliable, low-impedance ground connection system.

    Tools · PH-1 screwdriver · PH-3 screwdriver

    Accessories Material List on page 8: Items 1, 2, 6 and 9.

    Procedure To perform the mechanical installation of the unit, follow the steps below:

    Step Action

    1 Mount the brackets provided.

    2 With the M5 x 10 screw (B) and the two washers (C) screwed onthe right back side of MSADe, install the ring terminal of thegrounding cable (A), as shown below:

    A

    BC

    Continued on next page

  • 8/17/2019 MSAD Installation Ed1.1 En

    29/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    23

    Mechanical Installation, Continued

    Procedure

    (continued) Step Action3 Mount the chassis on the rack

    using the four M6 x 20 screws provided.

    4 Connect the other end of the grounding cable to the rackgrounding terminal using the item 9 from Material List on page 9.

    End of procedure

    NOTE In case of desktop installation , you should place the four adhesive feetincluded in the MSADe packaging (item 3 from Material List on page 8) at thebase of the unit for proper air circulation.

  • 8/17/2019 MSAD Installation Ed1.1 En

    30/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    24

    5 Cabling Instructions

    Only trained and qualified personnel should install or replace thisequipment.

    IF Cable Connection

    Tools · Torque wrench 4,4 Nm HEX 11 mm· U-type wrench 11 mm

    Accessories · IF cable prepared on page 15.· Material List on page 10: Item 13 (optional). You are suggested to use the

    angle adapter in case the IF cable routing might cause mechanical damageto the ODU receptacle on the front panel of MSADe.

    Continued on next page

  • 8/17/2019 MSAD Installation Ed1.1 En

    31/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    25

    IF Cable Connection, Continued

    ConnectionTo connect the IF cable, follow the steps below taking into consideration the

    following Cautions:Never connect or disconnect an IF cable when MSADe is ONand operating!

    There is risk of equipment failure.First switch-off the MSADe and then connect or disconnect the IFcable.Never apply a tightening torque greater than 4,4 Nm to theODU receptacle of MSADe!

    There is risk of equipment failure.

    Use the special tool (torque wrench 4,4 Nm, HEX 11 mm) whenperforming cabling to the receptacle.Never leave the IF cable without adequate lightningprotection in sites with increased lightning possibility.

    There is risk of equipment failure.For sites with increased lightning possibility (see page 13), youmust connect the lightning arrestor (item 14 from Material List onpage 10) to the IF cable (for the lightning arrestor connection,see page 26).

    Step Action

    1 (The step is optional).Use an 11 mm wrench to tight the angle adapter onto the ODUreceptacle on the front panel of MSADe. Do not over tight!

    2 Use a torque wrench to tight the IF cable onto the ODU receptacleor onto the angle adapter if you have performed step 1(tightening torque = 4,4 Nm).

  • 8/17/2019 MSAD Installation Ed1.1 En

    32/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    26

    IF Cable Lightning Arrestor Connection

    Tools · Blade·

    Crimping tool for 4 mm2

    cable· PH-3 cross-headed (Philips) screwdriver

    Accessories Item 14, 2 x Item 16 from Material List on page 10.

    Procedure To connect the lightning arrestor, follow the steps below:

    Step Action

    1 Strip the grounding cable to dimensions shown:

    2 Slide the M6 terminal ring over the wires at one end of thegrounding cable and crimp with the special crimping tool.

    3 Slide the M10 terminal ring over the wires at the other end of thegrounding cable and crimp with the special crimping tool.

    4 Pass the grounding cable terminated with the M10 ring throughthe lightning arrestor as shown in the photo below and tightenwith the nut.

    Continued on next page

  • 8/17/2019 MSAD Installation Ed1.1 En

    33/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    27

    IF Cable Lightning Arrestor Connection, Continued

    Procedure

    (continued) Step Action5 Connect the M6 terminal ring of the grounding cable to an

    appropriate grounding point of the rack.

    6 Never leave the grounding cable of the lightningarrestor unconnected.

    There is risk of equipment failure and / or electricalshock.Make sure you have connected the grounding cable toan appropriate grounding point of the rack beforeconnecting it to the coaxial cable coming from ODU.

    Connect the lightning arrestor at any point along the IF cabletaking into consideration the approximation to the stationgrounding bar (the length of the grounding cable is ~2 m).

  • 8/17/2019 MSAD Installation Ed1.1 En

    34/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    28

    I / O Alarms Connection

    Accessories Item 15 from Material List on page 10.

    Procedure To connect the I / O alarms, fo llow the steps below:

    Step Action

    1 Connect the open end to appropriate cross-connect moduleaccording to the chromatic code given below:

    Pin Signal Wire Color

    1 ALM_OUT2_NC Black

    2 RS232_TX * -

    3 RS232_RX * -

    4 ALM_OUT1_CM Brown

    5 RS232_GND * -

    6 ALM_OUT2_NO Red

    7 TTL_ALM_IN3_N 2 Orange

    8 TTL_ALM_IN4_N Yellow

    9 ALM_OUT1_NC Green

    10 ALM_OUT1_NO Blue

    11 ALM_OUT2_CM Purple

    12 TTL_ALM_IN3_P Gray

    13 TTL_ALM_IN4_P White

    14 TTL_ALM_IN1 3 Pink

    15 TTL_ALM_IN2 Light Green

    Shell Shell Black

    * These signals concern a Serial Console connection and areterminated onto the DB9 connector of the cable.

    Continued on next page

    2 Negative return terminal of alarm input pair 3 Single inputs with respect to ground

  • 8/17/2019 MSAD Installation Ed1.1 En

    35/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    29

    I / O Alarms Connection, Continued

    Procedure

    (continued) Step Action2 Plug the cable into the AUX receptacle shown in the figure

    below:

    Continued on next page

  • 8/17/2019 MSAD Installation Ed1.1 En

    36/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    30

    I / O Alarms Connection, Continued

    Input alarms

    connectioncircuit

    The dry-contact input alarms are internally pulled up to +3,3 V. When an

    external switch is closed, the corresponding signal is “low” (alarm condition).

    Output alarmsconnectioncircuit

    The alarms transmission circuit receives alarms in TTL form from themicroprocessor and routes them as external alarms in dry-contact form.When a “high” signal enters the relay’s driver, the relay is activated and

    current passes through the load of the corresponding alarm output.

    * The maximum ratings for the Voltage Source are:Max DC voltage: V=100 V DC and Max DC current: I L=200 mA DC (polarity isinsignificant)The loads can be indicator lamps, relays’ coils, buzzers, etc.

  • 8/17/2019 MSAD Installation Ed1.1 En

    37/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    31

    120 Ω E1 Tributary Channels Connection

    Info You should connect up to eight 120 Ω E1 tributary channels to the E1

    receptacles.

    Connectioncharacteristics

    Type of cable CAT5 or better, UTP, 4 pairs x AWG26

    Cable termination (unit side) RJ-45 plug

    Cable terminated on E1 1 to 8 receptacles on the unit front panelCable maximum length 198 m

    NOTE For the tributary cables preparation, you must take intoconsideration the pin-out of the E1 receptacle described on page38.Furthermore, if you intend to connect the MSADe to some other unit and not to a distribution frame, you must take intoconsideration the receptacle at the other end of the cable toappropriately prepare the cable (cross-over or straight).

  • 8/17/2019 MSAD Installation Ed1.1 En

    38/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    32

    75 Ω E1 Tributary Channels Connection

    Info You should connect up to eight baluns (75 Ω / 120 Ω adapters, item 11 from

    Material List on page 10) to the E1 receptacles through RJ-45 to RJ-45 cables(the cables can be provided on request, item 12 from Material List on page 10).

    Connectioncharacteristics

    Type of cable RG59 or equivalent, 75 Ω coaxial cable

    Cable termination (unit side) BNC male

    Cable terminated on BNC pair of receptacles at each balun

    Cable maximum length 266 m

    FE Connection

    Connectioncharacteristics

    Type of cable CAT5 or better, UTP, 4 pairs x AWG26

    Cable termination (moduleside)

    RJ-45 plug

    Cable terminated on ETH #1 to #4 receptacles on the unit frontpanel

    Cable maximum length 100 m

  • 8/17/2019 MSAD Installation Ed1.1 En

    39/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    33

    Management Connection

    Info You should connect the local configuration software tool AT_TOOL to the NMS

    receptacle for initial configuration of the radio parameters (frequencies, channelbandwidth etc.).

    Connectioncharacteristics

    Type of cable CAT5 or better

    Cable termination (unit side) RJ-45 plug

    Cable terminated on NMS receptacle on the unit front panel

    Cable maximum length 100 m

  • 8/17/2019 MSAD Installation Ed1.1 En

    40/49

  • 8/17/2019 MSAD Installation Ed1.1 En

    41/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    35

    Local DC Power Source Connection (for MSADe DC Models),Continued

    Tools · AZ-2,5 screwdriver

    Accessories One or two pairs of cables prepared on page 21.

    Procedure To connect the power supply, proceed as follows:

    Step Action

    1 Switch-off the local dc power supply source.

    2 Switch-off the single pole circuit breaker(s) connected betweenMSADe and the local dc power supply source.

    3 Connect the power supply cable(s) to the local dc power supplysource (Red cable: +V, blue cable: -V).

    4 Plug the power supply cable(s) into the POWER receptacle(s) (bothreceptacles are equivalent) on the front panel of MSADe withoutapplying force. Take into consideration the following Caution:

    The cable can be inserted only in one direction.The application of force during the insertion of the cable might cause damage to theequipment.

    Secure each connector in place using a AZ-2,5 screwdriver.

    End of procedure

  • 8/17/2019 MSAD Installation Ed1.1 En

    42/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    Appendix A – Receptacles Pin out

    36

    Local AC Power Source Connection (for MSADe AC Models)

    Prerequisites An earthed AC outlet 10 A of schuko type is required nearby the installation

    premises for the power cord to be plugged into.

    Accessories Item 5 from Material List on page 8.

    Procedure To connect the power supply, proceed as follows taking into consideration thefollowing Caution:

    Do not connect the power cord to mains until the end of this procedure.

    Possibility of equipment failure.

    First disconnect the power cord from mains (if connected)and then proceed to the procedure described hereinafter.

    Step Action

    1 Insert the female IEC plug of the cord into the AC INPUT receptacleat the front panel of MSADe.

    2 Insert the male plug of the cord into the AC outlet of schuko type atyour installation premises.

    End of procedure

  • 8/17/2019 MSAD Installation Ed1.1 En

    43/49

    Appendix A – Receptacles Pin out WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    37

    Appendix A – Receptacles Pin out

    ETH #1 to #4 Location Front Panel of MSADe

    Scope For Ethernet traffic (10 / 100 Mbit/s) provisioning andconnection to the IP / MPLS network

    Type RJ-45 Female

    Pin out

    Pin Signal Description1 TX+ Output+

    2 TX- Output-

    3 RX+ Input+

    4 N/A N/A

    5 N/A N/A

    6 RX- Input-

    7 N/A N/A

    8 N/A N/A

    Continued on next page

  • 8/17/2019 MSAD Installation Ed1.1 En

    44/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    Appendix A – Receptacles Pin out

    38

    Receptacles Pin out, Continued

    E1 #1 to #8 Location Front Panel of MSADe

    Scope For TDM traffic (2 Mbit/s) provisioning

    Type RJ-45 Female

    Pin out

    Pin Signal Description1 RX- Input-

    2 RX+ Input+

    3 N/A N/A

    4 TX- Output-

    5 TX+ Output+

    6 N/A N/A

    7 N/A N/A

    8 N/A N/A

    Continued on next page

  • 8/17/2019 MSAD Installation Ed1.1 En

    45/49

    Appendix A – Receptacles Pin out WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    39

    Receptacles Pin out, Continued

    NMS Location Front Panel of MSADe

    Scope For connection to the software tool AT_TOOL for local configuration of radio parameters

    Type RJ-45 Female

    Pin out

    Pin Signal Description1 TX+ Output+

    2 TX- Output-

    3 RX+ Input+

    4 N/A N/A

    5 N/A N/A

    6 RX- Input-

    7 N/A N/A

    8 N/A N/A

    SYNC Location Front Panel of MSADe

    Scope Clock Synchronization Interface(G.703 Clause 13)

    Type 1.0 / 2.3 (Micro Siemens)

    Pin out

    Pin Signal Description

    1 Sync Out Synchronization Output

    Continued on next page

  • 8/17/2019 MSAD Installation Ed1.1 En

    46/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    Appendix A – Receptacles Pin out

    40

    Receptacles Pin out, Continued

    AUX Location Front Panel of MSADe

    Scope For Serial Console (RS-232Interface) and Internal / External

    Alarms (Dry Contacts) connection

    Type D-Sub HD 15 Pin Female

    Pin out

    Pin Signal Description1 ALM_OUT2_NC Alarm Output 2 Normally Closed

    2 RS232_TX Transmit Data from MSADe

    3 RS232_RX Receive Data from PC

    4 ALM_OUT1_CM Alarm Output 1 Common

    5 RS232_GND RS232 Ground

    6 ALM_OUT2_NO Alarm Output 2 Normally Open

    7 TTL _ALM_IN3_N 1 Alarm Input 3 Negative

    8 TTL_ALM_IN4_N Alarm Input 4 Negative

    9 ALM_OUT1_NC Alarm Output 1 Normally Closed

    10 ALM_OUT1_NO Alarm Output 1 Normally Open

    11 ALM_OUT2_CM Alarm Output 2 Common

    12 TTL_ALM_IN3_P Alarm Input 3 Positive

    13 TTL_ALM_IN4_P Alarm Input 4 Positive

    14 TTL _ALM_IN1 2 Alarm Input 1

    15 TTL_ALM_IN2 Alarm Input 2

    Continued on next page

    1 Negative return terminal of alarm input pair 2 Single inputs with respect to ground

  • 8/17/2019 MSAD Installation Ed1.1 En

    47/49

    Appendix A – Receptacles Pin out WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    41

    Receptacles Pin out, Continued

    ODU Location Front Panel of MSADe

    Scope For connection to the Outdoor UnitThe receptacle carries the followingsignals:

    · -48 V dc power to the Outdoor Unit

    · Bidirectional Service Channel(S.C.) data, enablingcommunication between Indoor and Outdoor Units

    · The Rx IF signal (140 MHz)· The Tx IF signal

    (616,5 MHz for 10,5 GHz band,420 MHz for 26 / 28 GHz band)

    Type F type Female Coaxial 75 Ω

    Pin out

    Pin Signal Description

    Centre -48 V DC / S.C. / RX IF / TX IF Input / Output

    Shield Shield / Chassis GND N/A

    ODU PROTECT. Location Front Panel of MSADe

    Scope Reserved for future use

    Type USB type A

    Pin out

    Pin Signal Description1 +5V 5V power

    2 IF_CONTROL IF Control Out

    3 SC_CONTROL Service Channel Control Out

    4 DGND Ground

    Continued on next page

  • 8/17/2019 MSAD Installation Ed1.1 En

    48/49

    WiBAS MSADeInstallation and Cabling Manual - Edition 1.1

    Appendix A – Receptacles Pin out

    42

    Receptacles Pin out, Continued

    Power Location Front Panel of MSADe

    Scope For connection of –48 V dc power supply voltage

    Type Two poles Male power connector

    Pin out +-

    Pin Signal

    (+) Power Supply Return (GND)

    (-) -48 V dc, nominal(-40,5 V dc to -60 V dc)

    AC INPUT Location Front Panel of MSADe

    Scope For connection of ac power supplyvoltage

    Type AC Outlet (Male)

    Pin out Live (L) Neutral (N)

    Earth (E)

    Pin Signal DescriptionCentre EARTH Chassis GND

    Sides LIVE/NEUTRAL N/A

  • 8/17/2019 MSAD Installation Ed1.1 En

    49/49

    Intracom Telecom Regional Contacts

    Europe19.7 km. Markopoulou Ave.,19002 Peania, AthensGreecetel.: +30 2106671000fax: +30 [email protected]

    Asia-PacificOffice N° 507, 5th Floor,Welldone Technology Park,Sohna Road, Gurgaon, HaryanaIndiatel.: +91 124 4738500fax: +91 124 [email protected]

    Russia & CIS16 Krasnoproletarskaya Str.,Bldg.1, Entr.3, Moscow, 127473Russiatel.: +7 495 921 4881fax: +7 495 725 [email protected]

    America11360 Technology Circle,Duluth, GA 30097USAtel.: +1 770 295 2500fax: +1 770 295 [email protected]

    Middle East & AfricaBuilding No. 3 Office No. 204P.O. Box 500517, DubaiInternet City, Dubai,United Arab Emiratestel.: +971 4 362 5666fax: +971 4 390 [email protected]