Catalog – Drive System for Decentralized Installation 9
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVIFIT® MC for controlling MOVIMOT® drivesMOVIFIT®
2 MOVIFIT® 2.1 MOVIFIT® MC for controlling MOVIMOT® drives
The following figure shows a MOVIFIT® MC unit with three connected MOVIMOT®
helical gearmotors:
2.1.1 Features of MOVIFIT® MC• Up to three MOVIMOT® units can be connected via hybrid cable• Voltage range 3 x 380 500 V• Integrated power distribution and line protection• Integrated fieldbus interface
– PROFIBUS– PROFINET– DeviceNet– EtherNet/IP– Modbus TCP
• Maintenance switch• "Safe stop" function
– Safety category 3 according to EN 954-1 as well as PL d to EN ISO 13849-1– Stop categories 0 and 1 according to EN60204-1 (stop category 1 only in combi-
nation with external safety device)• Optional PROFIsafe extension /S11 with 4 x safe inputs and 2 x safe outputs• 12 digital inputs + 4 digital inputs/outputs• CAN/SBus interface• Simple and fast parameter setting via DIP switches or fieldbus
59512AXX
Pi
fkVA
Hz
n
10 Catalog – Drive System for Decentralized Installation
2 MOVIFIT® SC with integrated motor switchMOVIFIT®
2.2 MOVIFIT® SC with integrated motor switchThe following figure shows a MOVIFIT® SC unit with two connected helical gearmotors:
59513AXX
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 11
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVIFIT® SC with integrated motor switchMOVIFIT®
2.2.1 Features of MOVIFIT® SC• Electronic (contactless) motor starter
– When 2 motors are connected (dual motor starter): One direction of rotation– When one motor is connected (reversing starter): Two directions of rotation
• Power range– When 2 motors are connected: 2 x 0.37 to 2.2 kW– When 1 motor is connected: 1 x 0.37 to 4.0 kW
• Soft startup time can be set via parameters• Voltage range 3 x 380 500 V• Increased safety by switching of three phases• Integrated energy distribution• Integrated brake management for SEW three-wire brakes• Optional maintenance switch• Integrated fieldbus interface
– PROFIBUS– PROFINET– DeviceNet– EtherNet/IP– Modbus TCP
• Optional design without fieldbus interface as SBus slave• Digital inputs/outputs
Depends on the unit design, see following table:
• CAN/SBus interface• Simple and fast parameter setting via DIP switches (easy mode)• Expanded parameter setting via fieldbus or diagnostics interface (expert mode)
Digital inputs/outputs Function level Fieldbus interface
12 DI + 4 DI/O Technology or System All
16 DI + 2 DI/O Classic PROFIBUS or DeviceNet
14 DI Without SBus slave
Pi
fkVA
Hz
n
12 Catalog – Drive System for Decentralized Installation
2 MOVIFIT® FC with integrated frequency inverterMOVIFIT®
2.3 MOVIFIT® FC with integrated frequency inverterThe following figure shows a MOVIFIT® FC (size 1) with connected helical gearmotor:
2.3.1 SizesMOVIFIT® FC is available in two sizes, see the following figure:
59514AXX
62809AEN
0.37 to 1.5 kW 2.2 to 4 kW
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 13
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVIFIT® FC with integrated frequency inverterMOVIFIT®
2.3.2 Features of MOVIFIT® FC• Parameterizable open-loop frequency inverter• Power range from 0.37 to 4 kW (in two sizes) • Voltage range 3 x 380-500 V• Integrated energy distribution• Integrated brake management for SEW three-wire brakes• Optional internal braking resistor (integrated in ABOX)• Optional external braking resistor• Optional maintenance switch• Integrated fieldbus interface
– PROFIBUS– PROFINET– DeviceNet– EtherNet/IP– Modbus TCP
• Optional design without fieldbus interface as SBus slave• Digital inputs/outputs
Depends on the unit design, see following table:
• CAN/SBus interface• "Safe stop" function
– Safety category 3 according to EN 954-1 as well as PL d to EN ISO 13849-1– Stop categories 0 and 1 according to EN60204-1 (stop category 1 only in combi-
nation with external safety device)• Optional PROFIsafe extension /S11 with 4 x safe inputs and 2 x safe outputs• Simple and fast parameter setting via DIP switches (easy mode)• Expanded parameter setting via fieldbus or diagnostics interface (expert mode)
Digital inputs/outputs Function level Fieldbus interface
12 DI + 4 DI/O Technology or System All
16 DI + 2 DI/O Classic PROFIBUS or DeviceNet
14 DI Without SBus slave
Pi
fkVA
Hz
n
14 Catalog – Drive System for Decentralized Installation
2 Functional safetyMOVIFIT®
2.4 Functional safety2.4.1 Basic functions of MOVIFIT® MC and FC
Due to the integrated safety concept, the MOVIFIT® MC and MOVIFIT® FC units can besafely disconnected via the 24 V_P supply voltage as standard.This includes the function• STO1) = Safe Torque Off – corresponds to stop category 0 according to EN 60204-1
with fail-safe protection against restart according to EN 1037.In addition to that, a suitable external device (e.g. safety controller) can be used to real-ize stop category 1 according to EN 60204-1. The safety function of MOVIFIT® MC and FC is suitable for safety-related applicationsup to PL d according to EN ISO 13849-1 and category 3 according to EN 954-1.
2.4.2 Additional safety functions with the PROFIsafe option /S11For MOVIFIT® MC and MOVIFIT® FC in connection with the PROFIsafe option S11, theSTO safety function can also be controlled via PROFIsafe as an option on the basis ofthe fundamental functions.The safety-oriented PROFIsafe communication with the higher-level safety controllercan be realized via PROFIBUS or PROFINET.In addition to that, the S11 option has the following safe inputs/outputs:• 4 safe inputs (F-DI) for connection of up to 4 sensors• 2 safe outputs (F-DO), each with 2 pins, designed as P-M switch, for connection of
up to 2 actuatorsThis means that the safe inputs and outputs of the S11 PROFIsafe option are suitablefor safety-oriented applications up to SIL3 according to EN 61508, PL e according to ENISO 13849-1 and safety category 4 according to EN 954-1.The drive safety function (STO) is suitable for safety-oriented applications up to PL daccording to EN ISO 13849-1 and category 3 according to EN 954-1.
1) Definition of terminology according to IEC 61800-5-2
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 15
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Functional safetyMOVIFIT®
2.4.3 Example for decentralized installation: MOVIFIT® MC with PROFIsafe option S11
2.4.4 Example for decentralized installation: MOVIFIT® FC with PROFIsafe option S11
62807AEN
Power supply Safe inputs
Safe outputs
Light barrier
Safe output for STO
Hybrid cable
Safe stop
2-pole disconnection
PROFIsafe V2
PROFINET/PROFIBUS
3 x MOVIMOT® gearmotor
Lichtgitter
EMERGENCY STOP
Actuator 1
Actuator 2
MOVIFIT® MC
DI03
DI01
DI02
DI00
DI04
DI05
DI06
DI07
DI08
DI09
DI10
DI11
DI12/D
O00
DI13/D
O01
DI14/D
O02
DI15/D
o03SYS-F
BU
S-F
FB1
FB2
FB3
24V-C
24V-S
RU
NR
UN
OPT
RU
N-P
S
FD
I00FD
I01FD
I02FD
I03FD
I04FD
O0
FD
O1
FDO
2
Safety PLC
62808AEN
Power supply
Hybrid cable
Light barrier
PROFIsafe V2
PROFINET/PROFIBUS
Lichtgitter
EMERGENCY STOP
Actuator 1
Actuator 2
MOVIFIT® FC
Gearmotor
Internal
safe
disconnetion
(STO)
DI03
DI01
DI02
DI00
DI04
DI05
DI06
DI07
DI08
DI09
DI10
DI11
DI12/D
O00
DI13/D
O01
DI14/D
O02
DI15/D
o03SYS-F
BU
S-F
FB1
FB2
FB3
24V-C
24V-S
RU
NR
UN
OPT
RU
N-P
S
FD
I00FD
I01FD
I02FD
I03FD
I04FD
O0
FD
O1
FDO
2
Safe inputs
Safe outputs
Safety PLC
Pi
fkVA
Hz
n
16 Catalog – Drive System for Decentralized Installation
2 Function levelMOVIFIT®
2.5 Function levelThe function level describes the functions included in the software for MOVIFIT® unitsregarding operation, system control and diagnostics. The following figure gives an overview of the MOVIFIT® function levels:
62691AEN
Classic
Simple functionality
Fu
ncti
on
ality
Function level
Technology
with MOVI-PLC®
Open programming
System
with MOVIVISION®
Parameterizable industry solution
Control as fieldbus gateway
via MOVILINK®
Simple handling,
e.g. similar to control of
SEW field distributors
(Z.3, Z.6, etc.)
Target industry:
Mechanical engineering
Parameterizable
function blocks
Programming according
to IEC 61131
(e.g. in KOP, FUP, AWL,
ST, AS)
Multi-stage library concept
Target industry:
Materials handling
Central data storage for
decentralized units
Client/server architecture
Parameter and diagnostics
system
Drive-oriented materials
handling functions
Re-usable functions
Classic Technology System
NOTEFor detailed information on the MOVIFIT® function levels, refer to the relevant manuals:• "Classic Function Level" manual• "Technology Function Level" manual• "System Function Level" manual
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 17
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Unit conceptMOVIFIT®
2.6 Unit concept2.6.1 Features
The MOVIFIT® units have the following characteristics:• Aluminum die cast housing
– High rigidity– IP65 design for industrial requirements– Hygienic design with increased degree of protection and special surface treat-
ment for the food industry • Separation of connection unit (ABOX) and electronics (EBOX)
– No damage/contamination to the electronics during installation and maintenance– The bus address remains the same when the electronics (EBOX) is replaced– Data backup of user parameters in the ABOX is possible– Fast replacement of electronics without wiring: Only one screw is required to con-
nect the EBOX to the ABOX, see following figures.
Remove EBOX
Place EBOX on top of ABOX and screw it on62614AXX
62616AXX
EBOX
ABOX
1. 2.
EBOX
ABOX
1. 2.
Pi
fkVA
Hz
n
18 Catalog – Drive System for Decentralized Installation
2 Unit conceptMOVIFIT®
2.6.2 Unit designation exampleEBOX example
MT F 11 A 015- 50 3 - P1 0 A - 00 / S11 MOVIFIT® MC (MTM) MOVIFIT® SC (MTS) MOVIFIT® FC (MTF)
EBOX option EBOX option EBOX option
S11 =PROFIsafe option
Not available S11 =PROFIsafe option
EBOX design EBOX design EBOX design
00 = Series 00 = Series 00 = DT/DV motors + DZ motors
01 = DT/DV motors + DAS motors
A = Version
Function level
0 = Classic1 = Technology2 = System
Fieldbus
P1 = PROFIBUSD1 = DeviceNetE2 = PROFINETE3 = EtherNet/IP, Modbus TCPZ1 = SBus slave
Connection type Connection type Connection type
– 3 = 3-phase 3 = 3-phase
Supply voltage Supply voltage Supply voltage
– 50 = AC 380...500 V 50 = AC 380...500 V
Unit power Unit power Unit power
000 = MOVIFIT® MC
015 = 1.5 kW040 = 4.0 kW
003 = 0.37 kW005 = 0.55 kW007 = 0.75 kW011 = 1.1 kW015 = 1.5 kW022 = 2.2 kW030 = 3.0 kW040 = 4.0 kW
Version A
Series Series Series
11 = Standard 11 = Standard12 = Hygienicplus
11 = Standard12 = Hygienicplus
Unit type
M = MOVIFIT® MC (MOVIMOT® control)S = MOVIFIT® SC (motor starter)F = MOVIFIT® FC (frequency inverter)
MT = MOVIFIT® series
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 19
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Unit conceptMOVIFIT®
ABOX example
MT A 11 A - 50 3 -S02 1 - D 01 - 00 / BW1 MOVIFIT® MC (MTM) MOVIFIT® SC (MTS) MOVIFIT® FC (MTF)
ABOX option ABOX option ABOX option
Not available Not available BW1/BW2 = Integrated Braking resistor
ABOX type
00 = Series
Maintenance switch type 01 = With rotary button (ABB)
Maintenance switch type
Maintenance switch type
Maintenance switch type
M = Motor protection switch with line protection
D = Switch disconnector
D = Switch disconnector
Fieldbus 1 = PROFIBUS2 = DeviceNet3 = Ethernet
Connection configuration
Connection configuration
Connection configuration
S01 Standard S41 HybridS51 HybridS61 HybridH11 Han-Modular®H21 Han-Modular®
S02 Standard S42 HybridS52 HybridS62 HybridH12 Han-Modular®H22 Han-Modular®
S02 Standard S42 HybridS52 HybridS62 HybridH12 Han-Modular®H22 Han-Modular®
Connection type 3 = 3-phase (AC)
Supply voltage 50 = AC 380 V to 500 V
A = Version
Series Series Series
11 = Standard 11 = Standard12 = Hygienicplus
11 = Standard12 = Hygienicplus
Unit type A = Connection box
MT = MOVIFIT® unit series
Pi
fkVA
Hz
n
20 Catalog – Drive System for Decentralized Installation
2 Unit conceptMOVIFIT®
2.6.3 Possible combinations in connection with Standard ABOX and Hybrid ABOX
EBOX ABOX Design
MTM...-...-00
MOVIFIT® MC for controlling up to 3 MOVIMOT® drives
ABOX
MTA...-S01.-...-00 (in connection with MTM)MTA...-S02.-...-00 (in connection with
MTS/MTF)
Standard ABOX with terminals and cable glands1)
1) In conjunction with DeviceNet: Micro-style connector for DeviceNet connection
MTS...-...-00
MOVIFIT® SC with integrated motor switch
MTA...-S41.-...-00 (in connection with MTM)MTA...-S42.-...-00 (in connection with
MTS/MTF)
Hybrid ABOX with M12 for I/Os
MTF...-...-00
Size 1
Size 2
MOVIFIT® FC with integrated frequency inverter
MTA...-S51.-...-00 (in connection with MTM)MTA...-S52.-...-00 (in connection with
MTS/MTF)
Hybrid ABOX with M12 for I/Os and bus1)
MTA...-S61.-...-00 (in connection with MTM)MTA...-S62.-...-00 (in connection with
MTS/MTF)
Hybrid ABOX with M12 for I/Os and Push-Pull RJ45
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 21
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Unit conceptMOVIFIT®
2.6.4 Possible combinations in connection with Han-Modular® ABOX
EBOX ABOX
MTM...-...-00
MOVIFIT® MC for controlling up to 3 MOVIMOT® drives
MTA...-H11.-...-00 (in connection with MTM)MTA...-H12.-...-00 (in connection with MTS/MTF)
Han-Modular® ABOX with M12 for I/Os and bus and industrial plug connectors1)
1) In conjunction with DeviceNet: Micro-style connector for DeviceNet connection
MTS...-...-00
MOVIFIT® SC with integrated motor switch
MTA...-H21.-...-00 (in connection with MTM)MTA...-H22.-...-00 (in connection with MTS/MTF)
Han-Modular® ABOX with M12 for I/Os, Push-Pull RJ45 and industrial plug connectors
MTF...-...-00
Size 1
Size 2
MOVIFIT® FC with integrated frequency inverter
Pi
fkVA
Hz
n
22 Catalog – Drive System for Decentralized Installation
2 Hygienicplus designMOVIFIT®
2.7 Hygienicplus designThe following figures shows the Hygienicplus design of MOVIFIT®:
2.7.1 FeaturesThe Hygienicplus design has the following characteristics:• IP66 in accordance with EN 60529 and IP69K according to DIN 40050-9 (MOVIFIT®
housing closed and all cable bushings sealed according to the relevant degree ofprotection)
• Easy-to-clean housing (self-draining design) • Surface with anti-adhering properties• High impact resistance of the surface against mechanical damage• Compatibility with cleansing agents having the following properties:
– Alkaline– Acidic– Disinfectant
• Resistant to temperature fluctuations• Resistant to condensation caused by coated connection boards
62709AXX
NOTEDetailed technical data of the Hygienicplus design can be found in the following publi-cations• "MOVIFIT® SC" operating instructions• "MOVIFIT® FC" operating instructions
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 23
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Hygienicplus designMOVIFIT®
2.7.2 Combination options in connection with Hygienicplus design
NOTEThe Hygienicplus design is only available in connection with the following unit variants:• Only in connection with MOVIFIT® SC and MOVIFIT® FC• Only in connection with the Standard ABOX with terminals and cable bushings
EBOX ABOX Design
MTS12.-...-00
MOVIFIT® SC with integrated motor switch
MTA12.-S02.-...-00 (in connection with MTS/MTF)
Standard ABOX with terminals and cable bushings1)
MTF12.-...-00
Size 1
Size 2
MOVIFIT® FC with integrated frequency inverter
1) In conjunction with DeviceNet: Micro-style connector for DeviceNet connection
All representations of MOVIFIT® in Hygienicplus design are displayed as hatched (= special surface treatment) in SEW-EURODRIVE publications.
Pi
fkVA
Hz
n
24 Catalog – Drive System for Decentralized Installation
2 Hygienicplus designMOVIFIT®
2.7.3 ASEPTIC gearmotors DASSEW-EURODRIVE offers system solutions for entire production plants in the food andbeverage industry through the combination of gearmotors in ASEPTIC design, theASEPTICplus drive package and decentralized MOVIFIT® drive electronics in Hygienic-plus design.ASEPTIC gearmotors are not equipped with fans, which prevents a distribution of germsby air swirls. They are available in three motor sizes of types DAS80, DAS90 andDAS100 and can be mounted directly on helical, parallel shaft helical, helical-worm, he-lical-bevel or SPIROPLAN® gear units. The smooth surface of ASEPTIC gearmotorsmakes for easy cleaning. There is no build up of dirt with this design and it virtually pre-vents the formation of germs or bacteria.
11861AXX
NOTE
For more information and detailed technical data, refer to the "ASEPTIC gearmotorsDAS" catalog.
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 25
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Flexible connection technologyMOVIFIT®
2.8 Flexible connection technology2.8.1 Overview
The flexible connection technology of MOVIFIT® allows the unit to be adjusted to suitvarious installation philosophies. This flexibility is made possible thanks to the fact thatin addition to the standard version that has to be wired up, there are also prewired solu-tions with industry-standard connectors.• Standard ABOX
– With terminals and cable bushings
• Hybrid ABOX – With M12 for I/Os– With M12 for I/Os and bus– With M12 for I/Os and Push-Pull RJ45
• Han-Modular® ABOX – With M12 for I/Os and bus and industrial plug connectors– With M12 for I/Os, Push-Pull RJ45 and industrial plug connectors
Pi
fkVA
Hz
n
26 Catalog – Drive System for Decentralized Installation
2 Standard ABOX "MTA...-S01.-...-00", "MTA...-S02.-...-00"MOVIFIT®
2.9 Standard ABOX "MTA...-S01.-...-00", "MTA...-S02.-...-00" The following figure depicts the Standard ABOX with terminals and cable bushings. Inconnection with a DeviceNet interface, the Standard ABOX is always supplied withmicro-style connector:
62603AXX
[1] Maintenance switch (integrated as standard in connection with MOVIFIT® MC)[2] PE connection[3] Diagnostics socket (RJ10) underneath screw fitting
[2][1] [3]
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 27
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Standard ABOX "MTA...-S01.-...-00", "MTA...-S02.-...-00"MOVIFIT®
2.9.1 VariantsThe Standard ABOX is available in the following variants:• MTA11A-503-S01.-...-00: Standard ABOX for MOVIFIT® MC (MTM)
– Motor protection switch integrated as standard for line protection• MTA11A-503-S02.-...-00: Standard ABOX for MOVIFIT® SC (MTS) and FC (MTF)
– Optional external braking resistor (only MTF)– Optional integrated braking resistor (only MTF)– Optional switch disconnector
The following figure shows the cable glands and plug connectors of the Standard ABOXdepending on the fieldbus interface:
62610AXX
M25 M16
M20
M20
M16
M25 M16
M20
M20
M16
Micro-Style-
Connector X11
PROFIBUS
PROFINET
EtherNet/IP
Modbus TCP
DeviceNet MTA11A-503-S0.2-...-00
MTA11A-503-S0.1-...-00
MTA11A-503-S0.3-...-00
MTA11A-503-S0.3-...-00
MTA11A-503-S0.3-...-00
Pi
fkVA
Hz
n
28 Catalog – Drive System for Decentralized Installation
2 Standard ABOX "MTA...-S01.-...-00", "MTA...-S02.-...-00"MOVIFIT®
2.9.2 Connection assignment of the Standard ABOXConnection assignment for MOVIFIT® MC
62633AEN
X1 Power bus AC 380-500 VX7, X71 Hybrid cable MOVIMOT® 1 connectionX8, X81 Hybrid cable MOVIMOT® 2 connectionX9, X91 Hybrid cable MOVIMOT® 3 connectionX20 Power bus DC 24 VX29 DC 24 V distributor terminalX45 Connection terminal for option I/OsX25 Connection terminal for I/OsX30 In connection with PROFIBUS: PROFIBUS IN
In connection with PROFINET + EtherNet/IP + Modbus TCP: Ethernet port 1In connection with DeviceNet: Wired to X11 plug connector (micro-style connector)
X31 In connection with PROFIBUS: PROFIBUS OUTIn connection with PROFINET + EtherNet/IP + Modbus TCP: Ethernet port 2
X35 CAN/SBus connectionX50 Diagnostic socket (RJ10)
X1 X7 X8 X9 X71 X81 X91 X29 X20 X45 X25 X30 X31 X35 X50 X30 X31 X35 X50 X30 X35 X50
De
vic
eN
et
MTA
11
A-5
03
-S0
12
-...
-00
PR
OF
INE
T
Eth
erN
et/
IP
Mo
db
us
TC
P
MTA
11
A-5
03
-S0
13
-...
-00
PR
OF
IBU
S
MTA
11
A-5
03
-S0
11
-...
-00
1 2 3 4
2
1
5
4
3
1
2
3
8
7
4 5 6
1: DRAIN
2: V+
3: V-
4: CAND_H
5: CAND_L
1: TX+
2: TX-
3: RX+
4: res.
5: res.
6: RX-
7: res.
8: res.
1: +5V
2: RS+
3: RS-
4: 0V5
X50 (RJ10)
All variantsX30 (micro style connector)
Only with DeviceNet
X30+X31 (RJ45, ABOX internal)
Only with PROFINET,Ethernet/IP,Modbus TCP
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 29
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Standard ABOX "MTA...-S01.-...-00", "MTA...-S02.-...-00"MOVIFIT®
Connection assignment of MOVIFIT® SC and MOVIFIT® FC
62634AEN
X1 Power bus AC 380-500 VX8, X81 Motor 1 connectionX9, X91 Motor 2 connection (only with MOVIFIT® SC)X20 Power bus DC 24 VX29 DC 24 V distributor terminalX45 Connection terminal for option I/OsX25 Connection terminal for I/OsX30 In connection with PROFIBUS: PROFIBUS IN
In connection with PROFINET + EtherNet/IP + Modbus TCP: Ethernet port 1In connection with DeviceNet: Wired to X11 plug connector (micro-style connector)
X31 In connection with PROFIBUS: PROFIBUS OUTIn connection with PROFINET + EtherNet/IP + Modbus TCP: Ethernet port 2
X35 CAN/SBus connectionX50 Diagnostic socket (RJ10)
X1 X8 X9 X81 X91 X29 X20 X45 X25 X30 X31 X35 X50 X30 X31 X35 X50 X30 X35 X50
De
vic
eN
et
MTA
11
A-5
03
-S0
22
-...
-00
PR
OF
INE
T
Eth
erN
et/
IP
Mo
db
us
TC
P
MTA
11
A-5
03
-S0
23
-...
-00
PR
OF
IBU
S
MTA
11
A-5
03
-S0
21
-...
-00
1 2 3 4
2
1
5
4
3
1
2
3
8
7
4 5 6
1: DRAIN
2: V+
3: V-
4: CAND_H
5: CAND_L
1: TX+
2: TX-
3: RX+
4: res.
5: res.
6: RX-
7: res.
8: res.
1: +5V
2: RS+
3: RS-
4: 0V5
X50 (RJ10)
All variantsX30 (micro-style connector)
Only with DeviceNet
X30+X31 (RJ45, ABOX internal)
Only with PROFINET, Ethernet/IP, Modbus TCP
Pi
fkVA
Hz
n
30 Catalog – Drive System for Decentralized Installation
2 Hybrid ABOX "MTA...-S41.-...-00", "MTA...-S42.-...-00"MOVIFIT®
2.10 Hybrid ABOX "MTA...-S41.-...-00", "MTA...-S42.-...-00"
2.10.1 Description The following figure depicts the Hybrid ABOX with M12 plug connectors for connectingdigital I/Os:
NOTES• The Hybrid ABOX is based on the Standard ABOX. The following therefore only de-
scribes the additional plug connectors in comparison with the Standard ABOX.• For a description of the terminals, refer to sec. "Terminals/pin assignment of Stan-
dard ABOX". • Customers cannot use terminal strip X25 because the described plug connectors
are assigned to it.
62604AXX
[1] Maintenance switch (integrated as standard in connection with MOVIFIT® MC)[2] PE connection[3] M12 plug connector for I/Os[4] Diagnostics socket (RJ10) underneath screw fitting
[2][1] [3] [4]
X21
X25 X26 X27 X28
X22 X23 X24
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 31
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Hybrid ABOX "MTA...-S41.-...-00", "MTA...-S42.-...-00"MOVIFIT®
2.10.2 VariantsThe Hybrid ABOX is available in the following variants:• MTA11A-503-S41.-...-00: Hybrid ABOX for MOVIFIT® MC (MTM)
– Motor protection switch integrated as standard for line protection• MTA11A-503-S42.-...-00: Hybrid ABOX for MOVIFIT® SC (MTS) and FC (MTF)
– Optional external braking resistor (only MTF)– Optional integrated braking resistor (only MTF)– Optional switch disconnector
The following figure shows the cable glands and plug connectors of the Hybrid ABOX:
62611AEN
M25 M16
M20
M12, standard-coded, female
M12, standard-coded, female
M20
M16
PROFIBUS
PROFINET
EtherNet/IP
Modbus TCP
MTA11A-503-S4.1-...-00
MTA11A-503-S4.3-...-00
MTA11A-503-S4.3-...-00
MTA11A-503-S4.3-...-00
Pi
fkVA
Hz
n
32 Catalog – Drive System for Decentralized Installation
2 Hybrid ABOX "MTA...-S41.-...-00", "MTA...-S42.-...-00"MOVIFIT®
2.10.3 Connection assignment I/Os (X21 to X28)
I/Os12 DI + 4 DI/O Pin X21 X22 X23 X24
M12 plug connector, standard coding, female
1 VO24-I VO24-I VO24-II VO24-II
2 DI01 DI03 DI05 DI07
3 0V24_C 0V24_C 0V24_C 0V24_C
4 DI00 DI02 DI04 DI06
5 n.c. n.c. n.c. n.c.
No. X25 X26 X27 X28
1 VO24-III VO24-III VO24-IV VO24-IV
2 DI09 DI11 DI13/DO01 DI15/DO03
3 0V24_C 0V24_C 0V24_S 0V24_S
4 DI08 DI10 DI12 / DO00 DI14 / DO02
5 n.c. n.c. n.c. n.c.
6 DI + 2 DI/O Pin X21 X22 X23 X24
M12 plug connector, standard coding, female
1 VO24-I VO24-I VO24-II VO24-II
2 reserved reserved reserved reserved
3 0V24_C 0V24_C 0V24_C 0V24_C
4 DI00 DI01 DI02 DI03
5 n.c. n.c. n.c. n.c.
No. X25 X26 X27 X28
1 VO24-III VO24-III VO24-IV VO24-IV
2 reserved reserved reserved reserved
3 0V24_C 0V24_C 0V24_S 0V24_S
4 DI04 DI05 DI06 / DO00 DI07 / DO01
5 n.c. n.c. n.c. n.c.
4 DI Pin X21 X22 X23 - X28
M12 plug connector, standard coding, female
1 VO24 VO24 reserved
2 DI101 DI103 reserved
3 0V24_C 0V24_C reserved
4 DI100 DI102 reserved
5 n.c. n.c. reserved
12 DI + 4 DI/O
MOVIFIT® designs with 12 DI + 4 DI/O
MOVIFIT® Function level Fieldbus
MOVIFIT® MC All All
MOVIFIT® SC/FC Technology or System All
MOVIFIT® SC/FC Classic PROFINET, EtherNet/IP, Modbus TCP
6 DI + 2 DI/O
MOVIFIT® designs with 6 DI + 2 DI/O
MOVIFIT® Function level Fieldbus
MOVIFIT® SC/FC Classic PROFIBUS or DeviceNet
4 DIMOVIFIT® designs with 4 DI
MOVIFIT® Function level Fieldbus
MOVIFIT® SC/FC Without SBus slave
1
2
5
3
4
1
2
5
3
4
1
2
5
3
4
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 33
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Hybrid ABOX "MTA...-S51.-...-00", "MTA...-S52.-...-00"MOVIFIT®
2.11 Hybrid ABOX "MTA...-S51.-...-00", "MTA...-S52.-...-00"
2.11.1 DescriptionThe following figure depicts the Hybrid ABOX with M12 plug connectors for connectionof digital I/Os and bus:
NOTES• The Hybrid ABOX is based on the Standard ABOX. The following therefore only de-
scribes the additional plug connectors in comparison with the Standard ABOX.• For a description of the terminals, refer to sec. "Terminals/pin assignment of Stan-
dard ABOX". • Customers cannot use terminal strips X25, X30 and X31 because the described
plug connectors are assigned to them.
62605AXX
[1] Maintenance switch (integrated as standard in connection with MOVIFIT® MC)[2] PE connection[3] M12 plug connector for I/Os[4] Diagnostics socket (RJ10) below screw fitting[5] M12 plug connector for fieldbus connection
[2][1] [3] [4] [5]
X21
X25 X26 X27 X28
X22
X11 X12
X23 X24
Pi
fkVA
Hz
n
34 Catalog – Drive System for Decentralized Installation
2 Hybrid ABOX "MTA...-S51.-...-00", "MTA...-S52.-...-00"MOVIFIT®
2.11.2 VariantsThe Hybrid ABOX is available in the following variants:• MTA11A-503-S51.-...-00: Hybrid ABOX for MOVIFIT® MC (MTM)
– Motor protection switch integrated as standard for line protection• MTA11A-503-S52.-...-00: Hybrid ABOX for MOVIFIT® SC (MTS) and FC (MTF)
– Optional external braking resistor (only MTF)– Optional integrated braking resistor (only MTF)– Optional switch disconnector
The following figure shows the cable glands and plug connectors of the Hybrid ABOXdepending on the fieldbus interface:
62612AEN
M25 M16
M20
M12, standard-coded, female
M12, standard-coded, female
M20
M16
M12, B-coded,
male / female
M25 M16
M20
M12, standard-coded, female
M12, standard-coded, female
M20
M16
M12, D-coded,
female
M25
M20
M12, standard-coded, female
M12, standard-coded, female
M20
M16
M16
Micro-style
connector X11
PROFIBUS MTA11A-503-S5.1-...-00
PROFINET
EtherNet/IP
Modbus TCP
MTA11A-503-S5.3-...-00
MTA11A-503-S5.3-...-00
MTA11A-503-S5.3-...-00
DeviceNet MTA11A-503-S5.2-...-00
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 35
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Hybrid ABOX "MTA...-S51.-...-00", "MTA...-S52.-...-00"MOVIFIT®
2.11.3 Connection assignment of fieldbus interface (X11/X12)
PROFIBUSX11 (PROFIBUS IN) Pin Assignment X12 (PROFIBUS OUT) Pin Assignment
M12 plug connector, B coding, male
1 n.c. M12 plug connector, B coding, male
1 +5V_PB
2 A_IN 2 A_OUT
3 n.c. 3 0V5_PB
4 B_IN 4 B_OUT
5 n.c. 5 n.c.
Ethernet (PROFINET, EtherNet/IP or Modbus TCP)X11 (Port1) Pin Assignment X12 (Port2) Pin Assignment
M12 plug connector, D-coded, female
1 TX+ M12 plug connector, D-coded, female
1 TX+
2 TX- 2 TX-
3 RX+ 3 RX+
4 RX- 4 RX-
DeviceNetX11 Pin Assignment
Micro-style connector, standard coding, male
1 DRAIN
2 V+
3 V-
4 CAND_H
5 CAND_L
2
1
5
4
3
1
2
5
3
4
1
2
3
4
1
2
3
4
2
1
5
4
3
Pi
fkVA
Hz
n
36 Catalog – Drive System for Decentralized Installation
2 Hybrid ABOX "MTA...-S51.-...-00", "MTA...-S52.-...-00"MOVIFIT®
2.11.4 Connection assignment I/Os (X21 to X28)
I/Os12 DI + 4 DI/O Pin X21 X22 X23 X24
M12 plug connector, standard coding, female
1 VO24-I VO24-I VO24-II VO24-II
2 DI01 DI03 DI05 DI07
3 0V24_C 0V24_C 0V24_C 0V24_C
4 DI00 DI02 DI04 DI06
5 n.c. n.c. n.c. n.c.
Pin X25 X26 X27 X28
1 VO24-III VO24-III VO24-IV VO24-IV
2 DI09 DI11 DI13/DO01 DI15/DO03
3 0V24_C 0V24_C 0V24_S 0V24_S
4 DI08 DI10 DI12 / DO00 DI14 / DO02
5 n.c. n.c. n.c. n.c.
6 DI + 2 DI/O Pin X21 X22 X23 X24
M12 plug connector, standard coding, female
1 VO24-I VO24-I VO24-II VO24-II
2 reserved reserved reserved reserved
3 0V24_C 0V24_C 0V24_C 0V24_C
4 DI00 DI01 DI02 DI03
5 n.c. n.c. n.c. n.c.
Pin X25 X26 X27 X28
1 VO24-III VO24-III VO24-IV VO24-IV
2 reserved reserved reserved reserved
3 0V24_C 0V24_C 0V24_S 0V24_S
4 DI04 DI05 DI06 / DO00 DI07 / DO01
5 n.c. n.c. n.c. n.c.
4 DI Pin X21 X22 X23 - X28
M12 plug connector, standard coding, female
1 VO24 VO24 reserved
2 DI101 DI103 reserved
3 0V24_C 0V24_C reserved
4 DI100 DI102 reserved
5 n.c. n.c. reserved
12 DI + 4 DI/O
MOVIFIT® designs with 12 DI + 4 DI/O
MOVIFIT® Function level Fieldbus
MOVIFIT® MC All All
MOVIFIT® SC/FC Technology or System All
MOVIFIT® SC/FC Classic PROFINET, EtherNet/IP, Modbus TCP
6 DI + 2 DI/O
MOVIFIT® designs with 6 DI + 2 DI/O
MOVIFIT® Function level Fieldbus
MOVIFIT® SC/FC Classic PROFIBUS or DeviceNet
4 DIMOVIFIT® designs with 4 DI
MOVIFIT® Function level Fieldbus
MOVIFIT® SC/FC Without SBus slave
1
2
5
3
4
1
2
5
3
4
1
2
5
3
4
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 37
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Hybrid ABOX "MTA...-S61.-...-00" , "MTA...-S62.-...-00"MOVIFIT®
2.12 Hybrid ABOX "MTA...-S61.-...-00" , "MTA...-S62.-...-00"
2.12.1 DescriptionThe following figure depicts the Hybrid ABOX with M12 plug connectors for connectionof I/Os and plug connector Push-Pull RJ45 for Ethernet connection:
NOTES• The Hybrid ABOX is based on the Standard ABOX. The following therefore only de-
scribes the additional plug connectors in comparison with the Standard ABOX.• For a description of the terminals, refer to sec. "Terminals/pin assignment of Stan-
dard ABOX". • Customers cannot use terminal strips X25, X30 and X31 because the described
plug connectors are assigned to them.
62606AXX
[1] Maintenance switch (integrated as standard in connection with MOVIFIT® MC)[2] PE connection[3] M12 plug connector for I/Os[4] Diagnostics socket (RJ10) below screw fitting[5] Plug connector Push-Pull RJ45 for Ethernet connection
[2][1] [3] [4] [5]
X21 X22 X23 X24
X25 X26 X27 X28
X11 X12
Pi
fkVA
Hz
n
38 Catalog – Drive System for Decentralized Installation
2 Hybrid ABOX "MTA...-S61.-...-00" , "MTA...-S62.-...-00"MOVIFIT®
2.12.2 Variants The Hybrid ABOX is available in the following variants:• MTA11A-503-S61.-...-00: Hybrid ABOX for MOVIFIT® MC (MTM)
– Motor protection switch integrated as standard for line protection• MTA11A-503-S62.-...-00: Hybrid ABOX for MOVIFIT® SC (MTS) and FC (MTF)
– Optional external braking resistor (only MTF)– Optional integrated braking resistor (only MTF)– Optional switch disconnector
The following figure shows the cable glands and plug connectors of the Hybrid ABOX:
2.12.3 Connection assignment of fieldbus interface (X11/X12)
62613AEN
M25 M16
M20
M12, standard-coded, female
M12, standard-coded, female
M20
M16
Push-Pull
RJ45
PROFINET
EtherNet/IP
Modbus TCP
MTA11A-503-S6.3-...-00
MTA11A-503-S6.3-...-00
MTA11A-503-S6.3-...-00
Ethernet (PROFINET, EtherNet/IP or Modbus TCP)X11 (Port1) Pin Assignment X12 (Port2) Pin Assignment
Push-Pull RJ45 plug connector
1 TX+ Push-Pull RJ45 plug connector
1 TX+
2 TX- 2 TX-
3 RX+ 3 RX+
4 reserved 4 reserved
5 reserved 5 reserved
6 RX- 6 RX-
7 reserved 7 reserved
8 reserved 8 reserved
1
2
3
8
7
4 5 6
1
2
3
8
7
4 5 6
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 39
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Hybrid ABOX "MTA...-S61.-...-00" , "MTA...-S62.-...-00"MOVIFIT®
2.12.4 Connection assignment I/Os (X21 to X28)
I/Os12 DI + 4 DI/O Pin X21 X22 X23 X24
M12 plug connector, standard coding, female
1 VO24-I VO24-I VO24-II VO24-II
2 DI01 DI03 DI05 DI07
3 0V24_C 0V24_C 0V24_C 0V24_C
4 DI00 DI02 DI04 DI06
5 n.c. n.c. n.c. n.c.
Pin X25 X26 X27 X28
1 VO24-III VO24-III VO24-IV VO24-IV
2 DI09 DI11 DI13/DO01 DI15/DO03
3 0V24_C 0V24_C 0V24_S 0V24_S
4 DI08 DI10 DI12 / DO00 DI14 / DO02
5 n.c. n.c. n.c. n.c.
6 DI + 2 DI/O Pin X21 X22 X23 X24
M12 plug connector, standard coding, female
1 VO24-I VO24-I VO24-II VO24-II
2 reserved reserved reserved reserved
3 0V24_C 0V24_C 0V24_C 0V24_C
4 DI00 DI01 DI02 DI03
5 n.c. n.c. n.c. n.c.
Pin X25 X26 X27 X28
1 VO24-III VO24-III VO24-IV VO24-IV
2 reserved reserved reserved reserved
3 0V24_C 0V24_C 0V24_S 0V24_S
4 DI04 DI05 DI06 / DO00 DI07 / DO01
5 n.c. n.c. n.c. n.c.
4 DI Pin X21 X22 X23 - X28
M12 plug connector, standard coding, female
1 VO24 VO24 reserved
2 DI101 DI103 reserved
3 0V24_C 0V24_C reserved
4 DI100 DI102 reserved
5 n.c. n.c. reserved
12 DI + 4 DI/O
MOVIFIT® designs with 12 DI + 4 DI/O
MOVIFIT® Function level Fieldbus
MOVIFIT® MC All All
MOVIFIT® SC/FC Technology or System All
MOVIFIT® SC/FC Classic PROFINET, EtherNet/IP, Modbus TCP
6 DI + 2 DI/O
MOVIFIT® designs with 6 DI + 2 DI/O
MOVIFIT® Function level Fieldbus
MOVIFIT® SC/FC Classic PROFIBUS or DeviceNet
4 DIMOVIFIT® designs with 4 DI
MOVIFIT® Function level Fieldbus
MOVIFIT® SC/FC Without SBus slave
1
2
5
3
4
1
2
5
3
4
1
2
5
3
4
Pi
fkVA
Hz
n
40 Catalog – Drive System for Decentralized Installation
2 Han-Modular® ABOX "MTA...-H.1.-...-00", "MTA...-H.2.-...-00"MOVIFIT®
2.13 Han-Modular® ABOX "MTA...-H.1.-...-00", "MTA...-H.2.-...-00"2.13.1 Variants
The Han-Modular® ABOX is available in the following variants:• MTA11A-503-H21.-...-00, MTA11A-503-H11.-...-00:
Han-Modular® ABOX for MOVIFIT® MC (MTM)– Motor protection switch integrated as standard for line protection
• MTA11A-503-H22.-...-00, MTA11A-503-H12.-...-00:Han-Modular® ABOX for MOVIFIT® SC (MTS) and FC (MTF)– Optional external braking resistor (only MTF)– Optional integrated braking resistor (only MTF)– Switch disconnector integrated as standard
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 41
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Han-Modular® ABOX "MTA...-H.1.-...-00", "MTA...-H.2.-...-00"MOVIFIT®
2.13.2 Han-Modular® ABOX for MOVIFIT® MCThe following figure shows the Han-Modular® ABOX for MOVIFIT® MC depending onthe fieldbus interface:
62607AXX
[1] M12 plug connectors for I/Os[2] M23 plug connector (12-pole) for I/O extension box[3] SBus (CAN)[4] In connection with PROFIBUS: PROFIBUS IN
In connection with PROFINET + EtherNet/IP + Modbus TCP: Ethernet port 1In conjunction with DeviceNet: Wired to X11 plug connector (micro-style connector)
[5] In connection with PROFIBUS: PROFIBUS OUT or terminating resistorIn connection with PROFINET + EtherNet/IP + Modbus TCP: Ethernet port 2
[6] Diagnostics socket (RJ10) underneath the screw plug[7] Han-Modular® plug connector for connection of MOVIMOT® 3[8] Han-Modular® plug connector for connection of MOVIMOT® 2[9] Han-Modular® plug connector for connection of MOVIMOT® 1[10] Han-Modular® plug connector for power connection (power distribution with T adapter)[11] PE connection[12] M12 plug connectors for optional I/Os
[1] [2]
[4]
[3]
[5]
[12]
[9][10][11] [6][7][8]
X14
X11
X12
X19
X50
X14
X11
X21 X22 X23 X24
X41 X42 X43 X44
X25 X26 X27 X28
X11 X12
X19
X50
X14X19
X50
[4]
[5]
[4]
PROFINET
EtherNet/IP
MTA11A-503-H213-...-00
DeviceNet
MTA11A-503-H112-...-00
PROFIBUS
MTA11A-503-H111-...-00
X1X7 X8 X9
Pi
fkVA
Hz
n
42 Catalog – Drive System for Decentralized Installation
2 Han-Modular® ABOX "MTA...-H.1.-...-00", "MTA...-H.2.-...-00"MOVIFIT®
2.13.3 Han-Modular® ABOX for MOVIFIT® SC/FCThe following figure shows the Han-Modular® ABOX for MOVIFIT® SC/FC dependingon the fieldbus interface:
62608AXX
[1] M12 plug connectors for I/Os[2] M23 plug connector (12-pole) for I/O extension box[3] SBus (CAN)[4] In connection with PROFIBUS: PROFIBUS IN
In connection with PROFINET + EtherNet/IP + Modbus TCP: Ethernet port 1In connection with DeviceNet: Wired to X11 plug connector (micro-style connector)
[5] In connection with PROFIBUS: PROFIBUS OUT or terminating resistorIn connection with PROFINET + EtherNet/IP + Modbus TCP: Ethernet port 2
[6] Diagnostics socket (RJ10) underneath the screw plug[7] Han-Modular® plug connector for connection of an external braking resistor[8] Han-Modular® plug connector for connection of motor 2 (only MOVIFIT® SC)[9] Han-Modular® plug connector for connection of motor 1[10] Han-Modular® plug connector for power connection (power distribution with T adapter)[11] PE connection[12] M12 plug connectors for optional I/Os
[1] [2]
[4]
[3]
[5]
[12]
[9][10][11] [6][7][8]
X14
X11
X12
X19
X50
X21 X22 X23 X24
X41 X42 X43 X44
X25 X26 X27 X28
PROFINET
EtherNet/IP
MTA11A-503-H223-...-00 DeviceNet
MTA11A-503-H122-...-00
PROFIBUS
MTA11A-503-H121-...-00
X1
X7 X8 X9
[4]
X14
X11
X11 X12
X19
X50
X14X19
X50
[4]
[5]
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 43
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Han-Modular® ABOX "MTA...-H.1.-...-00", "MTA...-H.2.-...-00"MOVIFIT®
2.13.4 Connection assignment of the Han-Modular® ABOXConnection assignment of power bus
Power distribution and line protection• It is recommended that you use HARTING Power S products for power bus project
planning. • For the AC 400 V 50/60 Hz and DC 24 V supply, 2 cables with max. 6 mm2 can be
routed.• The spur lines that lead to the MOVIFIT® have a cross section of 4 mm2 and are a
maximum of 1.5 m long.• Power S products are available from Harting with part number 61 04 202 1069.
Power busX1 Pin Assignment
Han-Modular® with 2 module pin inserts, male
Module a (Han CC Protected)
a.1 Power supply phase L1
a.2 Power supply phase L2
a.3 Power supply phase L3
a.4 n.c.
Module b (Han EE)
b.1 +24V_C
b.2 n.c.
b.3 n.c.
b.4 +24V_S
b.5 0V24_C
b.6 n.c.
b.7 n.c.
b.8 0V24_S
Grounding pins
PE PE / housing
60507AXX
8
4
7
3
5
2
1
1
2 3 4
6
ba
Pi
fkVA
Hz
n
44 Catalog – Drive System for Decentralized Installation
2 Han-Modular® ABOX "MTA...-H.1.-...-00", "MTA...-H.2.-...-00"MOVIFIT®
MOVIMOT® connection (Han-Modular® ABOX for MOVIFIT® MC)
Motor 1/2 connection (Han-Modular® ABOX for MOVIFIT® SC/FC)
MOVIMOT® 1 to 3 Pin X7 X8 X9
Han-Modular® Compact with Han EE module, socket insert, female
1 0V24_MM 0V24_MM 0V24_MM
2 0V24_MM 0V24_MM 0V24_MM
3 L1_MM1 L1_MM2 L1_MM3
4 L3_MM1 L3_MM2 L3_MM3
5 +24V_MM +24V_MM +24V_MM
6 RS-_MM1 RS-_MM2 RS-_MM3
7 RS+_MM1 RS+_MM2 RS+_MM3
8 L2_MM1 L2_MM2 L2_MM3
PE PE PE PE
3
4 8
6
1
2
3
4
5
6
7
8
Motor 1/2 Pin X8 X91)
1) In connection with MOVIFIT® FC, the plug connector X9 is reserved.
Han-Modular® Compact with Han EE module, socket insert, female
1 TF+_M1 TF+_M2
2 13_M1 13_M2
3 U_M1 U_M2
4 W_M1 W_M2
5 TF-_M1 TF-_M2
6 14_M1 14_M2
7 15_M1 15_M2
8 V_M1 V_M2
PE PE_M1 PE_M2
External braking resistorX61)
1) In connection with MOVIFIT® SC, the plug connector X6 is reserved.
Pin Assignment
Han Q5/0, socket insert, female 1 n.c.
2 n.c.
3 +R
4 n.c.
5 -R
PE PE / housing
3
4 8
6
1
2
3
4
5
6
7
8
PE
1
3 5
4
2
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 45
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Han-Modular® ABOX "MTA...-H.1.-...-00", "MTA...-H.2.-...-00"MOVIFIT®
Connection assignment of fieldbus interface Ethernet (PROFINET, EtherNet/IP or Modbus TCP)
X11 (Port1) Pin Assignment X12 (Port2) Pin Assignment
Push-Pull RJ45 plug connector
1 TX+ Push-Pull RJ45 plug connector
1 TX+
2 TX- 2 TX-
3 RX+ 3 RX+
4 reserved 4 reserved
5 reserved 5 reserved
6 RX- 6 RX-
7 reserved 7 reserved
8 reserved 8 reserved
PROFIBUSX11 (PROFIBUS IN) Pin Assignment X12 (PROFIBUS OUT) Pin Assignment
M12 plug connector, B coding, male
1 n.c. M12 plug connector, B coding, male
1 +5V_PB
2 A_IN 2 A_OUT
3 n.c. 3 0V5_PB
4 B_IN 4 B_OUT
5 FE 5 FE
DeviceNetX11 Pin Assignment
Micro-style connector, standard coding, male
1 DRAIN
2 V+
3 V-
4 CAND_H
5 CAND_L
SBus (CAN)Can only be used in connection with function levels "Technology" or "System"
X14 Pin Assignment
M12 plug connector, standard coding, female
1 0V24_C
2 +24V_C_PS
3 CAN_GND
4 CAN_H
5 CAN_L
1
2
3
8
7
4 5 6
1
2
3
8
7
4 5 6
2
1
5
4
3
1
2
5
3
4
2
1
5
4
3
1
2
5
3
4
Pi
fkVA
Hz
n
46 Catalog – Drive System for Decentralized Installation
2 Han-Modular® ABOX "MTA...-H.1.-...-00", "MTA...-H.2.-...-00"MOVIFIT®
Connection assignment of I/Os I/Os
12 DI + 4 DI/O Pin X21 X22 X23 X24
M12 plug connector, standard coding, female
1 VO24-I VO24-I VO24-I VO24-II
2 DI01 DI03 DI05 DI07
3 0V24_C 0V24_C 0V24_C 0V24_C
4 DI00 DI02 DI04 DI06
5 FE FE FE FE
Pin X25 X26 X27 X28
1 VO24-II VO24-II VO24-IV VO24-IV
2 DI09 DI11 DI13/DO01 DI15/DO03
3 0V24_C 0V24_C 0V24_S 0V24_S
4 DI08 DI10 DI12 / DO00 DI14 / DO02
5 FE FE FE FE
6 DI + 2 DI/O Pin X21 X22 X23 X24
M12 plug connector, standard coding, female
1 VO24-I VO24-I VO24-I VO24-II
2 reserved reserved reserved reserved
3 0V24_C 0V24_C 0V24_C 0V24_C
4 DI00 DI01 DI02 DI03
5 FE FE FE FE
Pin X25 X26 X27 X28
1 VO24-II VO24-II VO24-IV VO24-IV
2 reserved reserved reserved reserved
3 0V24_C 0V24_C 0V24_S 0V24_S
4 DI04 DI05 DI06 / DO00 DI07 / DO01
5 FE FE FE FE
12 DI + 4 DI/O
MOVIFIT® designs with 12 DI + 4 DI/O
MOVIFIT® Function level Fieldbus
MOVIFIT® MC All All
MOVIFIT® SC/FC Technology or System All
MOVIFIT® SC/FC Classic PROFINET, EtherNet/IP, Modbus TCP
6 DI + 2 DI/O
MOVIFIT® designs with 6 DI + 2 DI/O
MOVIFIT® Function level Fieldbus
MOVIFIT® SC/FC Classic PROFIBUS or DeviceNet
1
2
5
3
4
1
2
5
3
4
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 47
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Han-Modular® ABOX "MTA...-H.1.-...-00", "MTA...-H.2.-...-00"MOVIFIT®
Connection assignment of diagnostic interface
I/O expansion (as an alternative for standard I/Os)Can only be used in connection with MOVIFIT® designs with 12 DI + 4 DI/O
X19 Pin Assignment
M23 plug connector (female)
1 DI01
2 DI03
3 DI05
4 DI07
5 DI09
6 DI11
7 DI13/DO01
8 DI15/DO03
9 0V24_C
10 0V24_C
11 V024-III
12 FE
Option I/Os with PROFIsafe option S11Pin X41 X42 X43 X44
M12 plug connector, standard coding, female
1 F-SS0 F-SS0 reserved reserved
2 F-DI01 F-DI03 F-DO00-M F-DO01-M
3 0V24_O 0V24_O 0V24_O 0V24_O
4 F-DI00 F-DI02 F-DO00-P F-DO01-P
5 F-SS1 F-SS1 reserved reserved
91
2 7
6
5
11
12
3
4
810
1
2
5
3
4
Diagnostic interface X50 Pin Assignment
Diagnostic interface X50 (RJ10 socket)
1 +5V
2 RS+
3 RS-
4 0V51 2 3 4
Pi
fkVA
Hz
n
48 Catalog – Drive System for Decentralized Installation
2 Connection options for encodersMOVIFIT®
2.14 Connection options for encoders
The following figure shows an example of a how to connect an NV26 proximity sensoror ES16 incremental encoder:
NOTES• MOVIFIT® units in connection with the "Technology" function level offer suitable in-
puts for connecting, monitoring and evaluating NV.. proximity sensors or ES.. incre-mental encoders.
• For detailed information on encoder connection, refer to the relevant MOVIFIT®
operating instructions.
62648AXX
NV26
ES16
MOVIFIT®
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 49
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
2.15 Selection tables in connection with Standard and Hybrid ABOX2.15.1 Available combinations of MOVIFIT® MCMOVIFIT® MC in connection with standard ABOX MTA...-S01.-...-00
Screw fittings
Option
EBOX ABOX
MC
MTM...-...-00MOVIFIT® MC for controlling up to 3
MOVIMOT® drives
MTA...-S01.-...-00Standard ABOX with terminals and cable
glands
Function level Fieldbus EBOX ABOX
Type Type
Classic PROFIBUS MTM11A000-P10A-00 MTA11A503-S011-M01-00
DeviceNet MTM11A000-D10A-00 MTA11A503-S012-M01-00
PROFINET (Cu) MTM11A000-E20A-00 MTA11A503-S013-M01-00
Technology PROFIBUS MTM11A000-P11A-00 MTA11A503-S011-M01-00
DeviceNet MTM11A000-D11A-00 MTA11A503-S012-M01-00
PROFINET (Cu) MTM11A000-E21A-00 MTA11A503-S013-M01-00
EtherNet/IP (Cu)Modbus TCP (Cu)
MTM11A000-E31A-00 MTA11A503-S013-M01-00
System PROFIBUS MTM11A000-P12A-00 MTA11A503-S011-M01-00
Type of screw fitting Figure Contents Size Part number
EMC cable gland (brass, nickel plated) 10 pieces M16 x 1.5 1820 478 3
10 pieces M20 x 1.5 1820 479 1
10 pieces M25 x 1.5 1820 480 5
Option Integrated in Type
PROFIsafe extension with4 x FDI + 2 x FDO
EBOX /S11I am
PR
O FIsafe
B U S
P R O F I®
PROCESS FIELD BUS
Pi
fkVA
Hz
n
50 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
MOVIFIT® MC in connection with hybrid ABOX MTA...-S41.-...-00
Screw fittings
Option
EBOX ABOX
MC
MTM...-...-00MOVIFIT® MC for controlling up to 3
MOVIMOT® drives
MTA...-S41.-...-00Hybrid ABOX with M12 for I/Os
Function level Fieldbus EBOX ABOX
Type Type
Classic PROFIBUS MTM11A000-P10A-00 MTA11A503-S411-M01-00
PROFINET (Cu) MTM11A000-E20A-00 MTA11A503-S413-M01-00
Technology PROFIBUS MTM11A000-P11A-00 MTA11A503-S411-M01-00
PROFINET (Cu) MTM11A000-E21A-00 MTA11A503-S413-M01-00
EtherNet/IP (Cu)Modbus TCP (Cu)
MTM11A000-E31A-00 MTA11A503-S413-M01-00
System PROFIBUS MTM11A000-P12A-00 MTA11A503-S411-M01-00
Type of screw fitting Figure Contents Size Part number
EMC cable gland (brass, nickel plated) 10 pieces M16 x 1.5 1820 478 3
10 pieces M20 x 1.5 1820 479 1
10 pieces M25 x 1.5 1820 480 5
Option Integrated in Type
PROFIsafe extension with4 x FDI + 2 x FDO
EBOX /S11I am
PR
O FIsafe
B U S
P R O F I®
PROCESS FIELD BUS
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 51
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
MOVIFIT® MC in connection with hybrid ABOX MTA...-S51.-...-00
Screw fittings
Option
EBOX ABOX
MC
MTM...-...-00MOVIFIT® MC for controlling up to 3
MOVIMOT® drives
MTA...-S51.-...-00Hybrid ABOX with M12 for I/Os and bus
Function level Fieldbus EBOX ABOX
Type Type
Classic PROFIBUS MTM11A000-P10A-00 MTA11A503-S511-M01-00
DeviceNet MTM11A000-D10A-00 MTA11A503-S512-M01-00
PROFINET (Cu) MTM11A000-E20A-00 MTA11A503-S513-M01-00
Technology PROFIBUS MTM11A000-P11A-00 MTA11A503-S511-M01-00
DeviceNet MTM11A000-E21A-00 MTA11A503-S512-M01-00
PROFINET (Cu) MTM11A000-E31A-00 MTA11A503-S513-M01-00
EtherNet/IP (Cu)Modbus TCP (Cu)
MTM11A000-E31A-00 MTA11A503-S513-M01-00
System PROFIBUS MTM11A000-P12A-00 MTA11A503-S511-M01-00
Type of screw fitting Figure Contents Size Part number
EMC cable gland (brass, nickel plated) 10 pieces M16 x 1.5 1820 478 3
10 pieces M20 x 1.5 1820 479 1
10 pieces M25 x 1.5 1820 480 5
Option Integrated in Type
PROFIsafe extension with4 x FDI + 2 x FDO
EBOX /S11I am
PR
O FIsafe
B U S
P R O F I®
PROCESS FIELD BUS
Pi
fkVA
Hz
n
52 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
MOVIFIT® MC in connection with hybrid ABOX MTA...-S61.-...-00
Screw fittings
Option
EBOX ABOX
MC
MTM...-...-00MOVIFIT® MC for controlling up to 3
MOVIMOT® drives
MTA...-S61.-...-00Hybrid ABOX with M12 for I/Os and
Push-Pull RJ45
Function level Fieldbus EBOX ABOX
Type Type
Classic PROFINET (Cu) MTM11A000-E20A-00 MTA11A503-S613-M01-00
Technology PROFINET (Cu) MTM11A000-E21A-00 MTA11A503-S613-M01-00
EtherNet/IP (Cu)Modbus TCP (Cu)
MTM11A000-E31A-00 MTA11A503-S613-M01-00
Type of screw fitting Figure Contents Size Part number
EMC cable gland (brass, nickel plated) 10 pieces M16 x 1.5 1820 478 3
10 pieces M20 x 1.5 1820 479 1
10 pieces M25 x 1.5 1820 480 5
Option Integrated in Type
PROFIsafe extension with4 x FDI + 2 x FDO
EBOX /S11I am
PR
O FIsafe
B U S
P R O F I®
PROCESS FIELD BUS
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 53
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
2.15.2 Hybrid cable for connecting MOVIFIT® MC and MOVIMOT®
MOVIFIT® MC Hybrid cable Length Cable type
Drive
ABOX
MTA...-S01.-...-00
MTA...-S41.-...-00
MTA...-S51.-...-00
MTA...-S61.-...-00
Part number: 0819 965 5 variable B MOVIMOT® with Plug connector AMA6
Part number: 0819 871 3 variable B MOVIMOT® with plug connector AMD6
Part number: 0819 966 3 variable B MOVIMOT® with APG6 plug connector
Part number: 0819 974 4 variable B MOVIMOT® with Cable glands
MOVIFIT® MC Hybrid cable roll Length Cable type
Drive
ABOX
MTA...-S01.-...-00
MTA...-S41.-...-00
MTA...-S51.-...-00
MTA...-S61.-...-00
Part number: 0818 735 5 (hybrid cable roll) 30 m B MOVIMOT® with Cable glands
Part number: 0593 714 0 (hybrid cable roll) 100 m B MOVIMOT® with Cable glands
Pi
fkVA
Hz
n
54 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
2.15.3 Available combinations of MOVIFIT® SCMOVIFIT® SC in connection with standard ABOX MTA...-S02.-...-00
Screw fittings
Option
EBOX ABOX
SC
MTS...-...-00MOVIFIT® SC with integrated motor
switch
MTA...-S02.-...-00Standard ABOX with terminals and
cable bushings
Function level Fieldbus Unit power EBOX ABOX
Type Type
Classic PROFIBUS 1.5 kW MTS11A015-503-P10A-00MTA11A503-S021-00
4.0 kW MTS11A040-503-P10A-00
DeviceNet 1.5 kW MTS11A015-503-D10A-00MTA11A503-S022-00
4.0 kW MTS11A040-503-D10A-00
PROFINET (Cu) 1.5 kW MTS11A015-503-E20A-00MTA11A503-S023-00
4.0 kW MTS11A040-503-E20A-00
Technology PROFIBUS 1.5 kW MTS11A015-503-P11A-00MTA11A503-S021-00
4.0 kW MTS11A040-503-P11A-00
DeviceNet 1.5 kW MTS11A015-503-D11A-00MTA11A503-S022-00
4.0 kW MTS11A040-503-D11A-00
PROFINET (Cu) 1.5 kW MTS11A015-503-E21A-00MTA11A503-S023-00
4.0 kW MTS11A040-503-E21A-00
EtherNet/IP(Cu)Modbus TCP (Cu)
1.5 kW MTS11A015-503-E31A-00MTA11A503-S023-004.0 kW MTS11A040-503-E31A-00
System PROFIBUS 1.5 kW MTS11A015-503-P12A-00MTA11A503-S021-00
4.0 kW MTS11A015-503-P12A-00
SBus slave Without 1.5 kW MTS11A015-503-Z10A-00MTA11A503-S021-00
4.0 kW MTS11A040-503-Z10A-00
Type of screw fitting Figure Contents Size Part number
EMC cable gland (brass, nickel plated) 10 pieces M16 x 1.5 1820 478 3
10 pieces M20 x 1.5 1820 479 1
10 pieces M25 x 1.5 1820 480 5
Option Integrated in Type
Maintenance switch ABOX MTA......-....-D01-00
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 55
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
MOVIFIT® SC in connection with standard ABOX and Hygienicplus design
NOTES• Enclosure IP69 is only achieved if the plastic screw plugs delivered as standard are
replaced by suitable IP69K screw plugs. • For screw plugs available at SEW-EURODRIVE, go to page 56.
EBOX ABOX
SC
MTS12...-...-00MOVIFIT® SC with integrated motor
switch (Hygienicplus design)
MTA12...-S02.-...-00Standard ABOX with terminals and cable glands
(Hygienicplus design)
All representations of MOVIFIT® in Hygienicplus design are displayed as hatched (= special surface treatment) in SEW-EURODRIVE publications.
Function level Fieldbus Unit power EBOX ABOX
Type Type
Classic PROFIBUS 1.5 kW MTS12A015-503-P10A-00MTA12A503-S021-00
4.0 kW MTS12A040-503-P10A-00
DeviceNet 1.5 kW MTS12A015-503-D10A-00MTA12A503-S022-00
4.0 kW MTS12A040-503-D10A-00
PROFINET (Cu) 1.5 kW MTS12A015-503-E20A-00MTA12A503-S023-00
4.0 kW MTS12A040-503-E20A-00
Technology PROFIBUS 1.5 kW MTS12A015-503-P11A-00MTA12A503-S021-00
4.0 kW MTS12A040-503-P11A-00
DeviceNet 1.5 kW MTS12A015-503-D11A-00MTA12A503-S022-00
4.0 kW MTS12A040-503-D11A-00
PROFINET (Cu) 1.5 kW MTS12A015-503-E21A-00MTA12A503-S023-00
4.0 kW MTS12A040-503-E21A-00
EtherNet/IP(Cu)Modbus TCP (Cu)
1.5 kW MTS12A015-503-E31A-00MTA12A503-S023-004.0 kW MTS12A040-503-E31A-00
System PROFIBUS 1.5 kW MTS12A015-503-P12A-00MTA12A503-S021-00
4.0 kW MTS12A015-503-P12A-00
SBus slave Without 1.5 kW MTS12A015-503-Z10A-00MTA12A503-S021-00
4.0 kW MTS12A040-503-Z10A-00
Pi
fkVA
Hz
n
56 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
Screw fittings
Type of screw fitting Degree of protec-tion
Figure Contents Size Part number
Stainless steel screw plugs IP69K 10 pieces M16 x 1.5 1820 223 3
10 pieces M20 x 1.5 1820 224 1
10 pieces M25 x 1.5 1820 226 8
EMC cable gland (brass, nickel plated) IP66 10 pieces M16 x 1.5 1820 478 3
10 pieces M20 x 1.5 1820 479 1
10 pieces M25 x 1.5 1820 480 5
EMC cable gland (stainless steel) IP69K 10 pieces M16 x 1.5 1821 636 6
10 pieces M20 x 1.5 1821 637 4
10 pieces M25 x 1.5 1821 638 2
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 57
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
MOVIFIT® SC in connection with hybrid ABOX MTA...-S42.-...-00
Screw fittings
Option
EBOX ABOX
SC
MTS...-...-00MOVIFIT® SC with integrated motor
switch
MTA...-S42.-...-00Hybrid ABOX with M12 for I/Os
Function level Fieldbus Unit power EBOX ABOX
Type Type
Classic PROFIBUS 1.5 kW MTS11A015-503-P10A-00MTA11A503-S421-00
4.0 kW MTS11A040-503-P10A-00
PROFINET (Cu) 1.5 kW MTS11A015-503-E20A-00MTA11A503-S423-00
4.0 kW MTS11A040-503-E20A-00
Technology PROFIBUS 1.5 kW MTS11A015-503-P11A-00MTA11A503-S421-00
4.0 kW MTS11A040-503-P11A-00
PROFINET (Cu) 1.5 kW MTS11A015-503-E21A-00MTA11A503-S423-00
4.0 kW MTS11A040-503-E21A-00
EtherNet/IP(Cu)Modbus TCP (Cu)
1.5 kW MTS11A015-503-E31A-00MTA11A503-S423-004.0 kW MTS11A040-503-E31A-00
System PROFIBUS 1.5 kW MTS11A015-503-P12A-00MTA11A503-S421-00
4.0 kW MTS11A015-503-P12A-00
SBus slave Without 1.5 kW MTS11A015-503-Z10A-00MTA11A503-S421-00
4.0 kW MTS11A040-503-Z10A-00
Type of screw fitting Figure Contents Size Part number
EMC cable gland (brass, nickel plated) 10 pieces M16 x 1.5 1820 478 3
10 pieces M20 x 1.5 1820 479 1
10 pieces M25 x 1.5 1820 480 5
Option Integrated in Type
Maintenance switch ABOX MTA......-....-D01-00
Pi
fkVA
Hz
n
58 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
MOVIFIT® SC in connection with hybrid ABOX MTA...-S52.-...-00
Screw fittings
Option
EBOX ABOX
SC
MTS...-...-00MOVIFIT® SC with integrated motor
switch
MTA...-S52.-...-00Hybrid ABOX with M12 for I/Os and bus
Function level Fieldbus Unit power EBOX ABOX
Type Type
Classic PROFIBUS 1.5 kW MTS11A015-503-P10A-00MTA11A503-S521-00
4.0 kW MTS11A040-503-P10A-00
DeviceNet 1.5 kW MTS11A015-503-D10A-00MTA11A503-S522-00
4.0 kW MTS11A040-503-D10A-00
PROFINET (Cu) 1.5 kW MTS11A015-503-E20A-00MTA11A503-S523-00
4.0 kW MTS11A040-503-E20A-00
Technology PROFIBUS 1.5 kW MTS11A015-503-P11A-00MTA11A503-S521-00
4.0 kW MTS11A040-503-P11A-00
DeviceNet 1.5 kW MTS11A015-503-D11A-00MTA11A503-S522-00
4.0 kW MTS11A040-503-D11A-00
PROFINET (Cu) 1.5 kW MTS11A015-503-E21A-00MTA11A503-S523-00
4.0 kW MTS11A040-503-E21A-00
EtherNet/IP (Cu)Modbus TCP (Cu)
1.5 kW MTS11A015-503-E31A-00MTA11A503-S523-004.0 kW MTS11A040-503-E31A-00
System PROFIBUS 1.5 kW MTS11A015-503-P12A-00MTA11A503-S521-00
4.0 kW MTS11A015-503-P12A-00
Type of screw fitting Figure Contents Size Part number
EMC cable gland (brass, nickel plated) 10 pieces M16 x 1.5 1820 478 3
10 pieces M20 x 1.5 1820 479 1
10 pieces M25 x 1.5 1820 480 5
Option Integrated in Type
Maintenance switch ABOX MTA......-....-D01-00
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 59
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
MOVIFIT® SC in connection with hybrid ABOX MTA...-S62.-...-00
Screw fittings
Option
EBOX ABOX
SC
MTS...-...-00MOVIFIT® SC with integrated motor
switch
MTA...-S62.-...-00Hybrid ABOX with M12 for I/Os and
Push-Pull RJ45
Function level Fieldbus Unit power EBOX ABOX
Type Type
Classic PROFINET (Cu) 1.5 kW MTS11A015-503-E20A-00MTA11A503-S623-00
4.0 kW MTS11A040-503-E20A-00
Technology PROFINET (Cu) 1.5 kW MTS11A015-503-E21A-00MTA11A503-S623-00
4.0 kW MTS11A040-503-E21A-00
EtherNet/IP(Cu)Modbus TCP (Cu)
1.5 kW MTS11A015-503-E31A-00MTA11A503-S623-004.0 kW MTS11A040-503-E31A-00
Type of screw fitting Figure Contents Size Part number
EMC cable gland (brass, nickel plated) 10 pieces M16 x 1.5 1820 478 3
10 pieces M20 x 1.5 1820 479 1
10 pieces M25 x 1.5 1820 480 5
Option Integrated in Type
Maintenance switch ABOX MTA......-....-D01-00
Pi
fkVA
Hz
n
60 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
2.15.4 Hybrid cable for connecting MOVIFIT® SC to motors
MOVIFIT® SC Hybrid cable Length Cable type
Drive
ABOX
MTA...-S02.-...-00
MTA...-S42.-...-00
MTA...-S52.-...-00
MTA...-S62.-...-00
Part number DT71-90 (star): 0819 967 1Part number DT71-90 (delta): 0819 969 8Part number DV100 (star): 0819 970 1Part number DV100 (delta): 0819 874 8
variable A Motor with ISU4 plug connector
Part number: 0819 972 8 variable A • Motor with ASB4 plug connector• Motor with ASB8 plug connector
Part number: 0819 875 6 variable A • Motor with AMB4 plug connector• Motor with AMB8 plug connector
Part number: 0819 973 6 variable A Motor with APG4 plug connector
Part number: 0819 975 2 variable A Motor with cable glands
MOVIFIT® SC Hybrid cable roll Cable length
Cable type
Drive
ABOX
MTA...-S02.-...-00
MTA...-S42.-...-00
MTA...-S52.-...-00
MTA...-S62.-...-00
Part number: 0 818 736 3 (hybrid cable roll) 30 m A • Motor with cable glands• ASEPTIC DAS motor
Part number: 0 818 739 8 (hybrid cable roll) 100 m A • Motor with cable glands• ASEPTIC DAS motor
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 61
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
2.15.5 Available combinations of MOVIFIT® FCMOVIFIT® FC in connection with standard ABOX MTA...-S02.-...-00
EBOX ABOX
FC
MTF...-...-00MOVIFIT® FC with integrated
frequency inverter
Size 1
Size 2
MTA...-S02.-...-00Standard ABOX with terminals and cable
bushings
Function level
Fieldbus Unit power Size EBOX ABOX
Type Type
Classic PROFIBUS 0.37 kW
1
MTF11A003-503-P10A-00
MTA11A503-S021-00
0.55 kW MTF11A005-503-P10A-00
0.75 kW MTF11A007-503-P10A-00
1.1 kW MTF11A011-503-P10A-00
1.5 kW MTF11A015-503-P10A-00
2.2 kW
2
MTF11A022-503-P10A-00
3.0 kW MTF11A030-503-P10A-00
4.0 kW MTF11A040-503-P10A-00
DeviceNet 0.37 kW
1
MTF11A003-503-D10A-00
MTA11A503-S022-00
0.55 kW MTF11A005-503-D10A-00
0.75 kW MTF11A007-503-D10A-00
1.1 kW MTF11A011-503-D10A-00
1.5 kW MTF11A015-503-D10A-00
2.2 kW
2
MTF11A022-503-D10A-00
3.0 kW MTF11A030-503-D10A-00
4.0 kW MTF11A040-503-D10A-00
PROFINET (Cu) 0.37 kW
1
MTF11A003-503-E20A-00
MTA11A503-S023-00
0.55 kW MTF11A005-503-E20A-00
0.75 kW MTF11A007-503-E20A-00
1.1 kW MTF11A011-503-E20A-00
1.5 kW MTF11A015-503-E20A-00
2.2 kW
2
MTF11A022-503-E20A-00
3.0 kW MTF11A030-503-E20A-00
4.0 kW MTF11A040-503-E20A-00
Pi
fkVA
Hz
n
62 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
Tech-nology
PROFIBUS 0.37 kW
1
MTF11A003-503-P11A-00
MTA11A503-S021-00
0.55 kW MTF11A005-503-P11A-00
0.75 kW MTF11A007-503-P11A-00
1.1 kW MTF11A011-503-P11A-00
1.5 kW MTF11A015-503-P11A-00
2.2 kW
2
MTF11A022-503-P11A-00
3.0 kW MTF11A030-503-P11A-00
4.0 kW MTF11A040-503-P11A-00
DeviceNet 0.37 kW
1
MTF11A003-503-D11A-00
MTA11A503-S022-00
0.55 kW MTF11A005-503-D11A-00
0.75 kW MTF11A007-503-D11A-00
1.1 kW MTF11A011-503-D11A-00
1.5 kW MTF11A015-503-D11A-00
2.2 kW
2
MTF11A022-503-D11A-00
3.0 kW MTF11A030-503-D11A-00
4.0 kW MTF11A040-503-D11A-00
PROFINET (Cu) 0.37 kW
1
MTF11A003-503-E21A-00
MTA11A503-S023-00
0.55 kW MTF11A005-503-E21A-00
0.75 kW MTF11A007-503-E21A-00
1.1 kW MTF11A011-503-E21A-00
1.5 kW MTF11A015-503-E21A-00
2.2 kW
2
MTF11A022-503-E21A-00
3.0 kW MTF11A030-503-E21A-00
4.0 kW MTF11A040-503-E21A-00
EtherNet/IP (Cu)Modbus TCP (CU)
0.37 kW
1
MTF11A003-503-E31A-00
MTA11A503-S023-00
0.55 kW MTF11A005-503-E31A-00
0.75 kW MTF11A007-503-E31A-00
1.1 kW MTF11A011-503-E31A-00
1.5 kW MTF11A015-503-E31A-00
2.2 kW
2
MTF11A022-503-E31A-00
3.0 kW MTF11A030-503-E31A-00
4.0 kW MTF11A040-503-E31A-00
System PROFIBUS 0.37 kW
1
MTF11A003-503-P12A-00
MTA11A503-S021-00
0.55 kW MTF11A005-503-P12A-00
0.75 kW MTF11A007-503-P12A-00
1.1 kW MTF11A011-503-P12A-00
1.5 kW MTF11A015-503-P12A-00
2.2 kW
2
MTF11A022-503-P12A-00
3.0 kW MTF11A030-503-P12A-00
4.0 kW MTF11A040-503-P12A-00
Function level
Fieldbus Unit power Size EBOX ABOX
Type Type
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 63
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
Screw fittings
Options
SBus slave
Without 0.37 kW
1
MTF11A003-503-Z10A-00
MTA11A503-S021-00
0.55 kW MTF11A005-503-Z10A-00
0.75 kW MTF11A007-503-Z10A-00
1.1 kW MTF11A011-503-Z10A-00
1.5 kW MTF11A015-503-Z10A-00
2.2 kW
2
MTF11A022-503-Z10A-00
3.0 kW MTF11A030-503-Z10A-00
4.0 kW MTF11A040-503-Z10A-00
Function level
Fieldbus Unit power Size EBOX ABOX
Type Type
Type of screw fitting Figure Contents Size Part number
EMC cable gland (brass, nickel plated) 10 pieces M16 x 1.5 1820 478 3
10 pieces M20 x 1.5 1820 479 1
10 pieces M25 x 1.5 1820 480 5
Option Integrated in Type
Maintenance switch ABOX MTA......-....-D01-00
Internal braking resistor ABOX MTF11A003... to MTF11A015...:/BW1 (part number 1820 705 7)
ABOX MTF11A003... to MTF11A040...:/BW2 (part number 1820 754 5)
PROFIsafe extension with4 x FDI + 2 x FDO
EBOX /S11I am
PR
O FIsafe
B U S
P R O F I®
PROCESS FIELD BUS
Pi
fkVA
Hz
n
64 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
External braking resistors
Assigned motor The listed MOVIFIT® combinations are designed for connection to SEW-EURODRIVEDT/DV and DZ motors.A MOVIFIT® unit for connecting additional SEW-EURODRIVE motors must be orderedas shown in the following example:
Braking resistor MOVIFIT® type Part number Protective grid
BW200-003/K-1.5 MTF11A003... to MTF11A015...
0 828 291 9 0 813 152 X
BW200-005/K-1.5 0 828 283 8 -
BW150-010 0 802 285 2 -
BW100-003/K-1.5 MTF11A022... to MTF11A040...
0 828 293 5 0 813 152 X
BW100-005/K-1.5 0 828 286 2 -
BW068-010 0 802 287 9 -
BW068-020 0 802 286 0 -
MOVIFIT® EBOX MTF11A003-503-E20A-0000 = DT/DV motors + DZ motors
01 = DT/DV motors + DAS motors
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 65
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
MOVIFIT® FC in connection with standard ABOX and Hygienicplus design
NOTES• Enclosure IP69 is only achieved if the plastic screw plugs delivered as standard are
replaced by suitable IP69K screw plugs. • For screw plugs available at SEW-EURODRIVE, go to page 68.
EBOX ABOX
FC
MTF12...-...-00MOVIFIT® FC with integrated fre-
quency inverter (Hygienicplus design)
Size 1
Size 2
MTA12...-S02.-...-00Standard ABOX with terminals and cable
glands (Hygienicplus design)
All representations of MOVIFIT® in Hygienicplus design are displayed as hatched (= special surface treatment) in SEW-EURODRIVE publications.
Function level
Fieldbus Unit power Size EBOX ABOX
Type Type
Classic PROFIBUS 0.37 kW
1
MTF12A003-503-P10A-00
MTA12A503-S021-00
0.55 kW MTF12A005-503-P10A-00
0.75 kW MTF12A007-503-P10A-00
1.1 kW MTF12A011-503-P10A-00
1.5 kW MTF12A015-503-P10A-00
2.2 kW
2
MTF12A022-503-P10A-00
3.0 kW MTF12A030-503-P10A-00
4.0 kW MTF12A040-503-P10A-00
DeviceNet 0.37 kW
1
MTF12A003-503-D10A-00
MTA12A503-S022-00
0.55 kW MTF12A005-503-D10A-00
0.75 kW MTF12A007-503-D10A-00
1.1 kW MTF12A011-503-D10A-00
1.5 kW MTF12A015-503-D10A-00
2.2 kW
2
MTF12A022-503-D10A-00
3.0 kW MTF12A030-503-D10A-00
4.0 kW MTF12A040-503-D10A-00
Pi
fkVA
Hz
n
66 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
Classic PROFINET (Cu) 0.37 kW
1
MTF12A003-503-E20A-00
MTA12A503-S023-00
0.55 kW MTF12A005-503-E20A-00
0.75 kW MTF12A007-503-E20A-00
1.1 kW MTF12A011-503-E20A-00
1.5 kW MTF12A015-503-E20A-00
2.2 kW
2
MTF12A022-503-E20A-00
3.0 kW MTF12A030-503-E20A-00
4.0 kW MTF12A040-503-E20A-00
Technol-ogy
PROFIBUS 0.37 kW
1
MTF12A003-503-P11A-00
MTA12A503-S021-00
0.55 kW MTF12A005-503-P11A-00
0.75 kW MTF12A007-503-P11A-00
1.1 kW MTF12A011-503-P11A-00
1.5 kW MTF12A015-503-P11A-00
2.2 kW
2
MTF12A022-503-P11A-00
3.0 kW MTF12A030-503-P11A-00
4.0 kW MTF12A040-503-P11A-00
DeviceNet 0.37 kW
1
MTF12A003-503-D11A-00
MTA12A503-S022-00
0.55 kW MTF12A005-503-D11A-00
0.75 kW MTF12A007-503-D11A-00
1.1 kW MTF12A011-503-D11A-00
1.5 kW MTF12A015-503-D11A-00
2.2 kW
2
MTF12A022-503-D11A-00
3.0 kW MTF12A030-503-D11A-00
4.0 kW MTF12A040-503-D11A-00
PROFINET (Cu) 0.37 kW
1
MTF12A003-503-E21A-00
MTA12A503-S023-00
0.55 kW MTF12A005-503-E21A-00
0.75 kW MTF12A007-503-E21A-00
1.1 kW MTF12A011-503-E21A-00
1.5 kW MTF12A015-503-E21A-00
2.2 kW
2
MTF12A022-503-E21A-00
3.0 kW MTF12A030-503-E21A-00
4.0 kW MTF12A040-503-E21A-00
EtherNet/IP (Cu)Modbus TCP (CU)
0.37 kW
1
MTF12A003-503-E31A-00
MTA12A503-S023-00
0.55 kW MTF12A005-503-E31A-00
0.75 kW MTF12A007-503-E31A-00
1.1 kW MTF12A011-503-E31A-00
1.5 kW MTF12A015-503-E31A-00
2.2 kW
2
MTF12A022-503-E31A-00
3.0 kW MTF12A030-503-E31A-00
4.0 kW MTF12A040-503-E31A-00
Function level
Fieldbus Unit power Size EBOX ABOX
Type Type
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 67
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
Options
External braking resistors
System PROFIBUS 0.37 kW
1
MTF12A003-503-P12A-00
MTA12A503-S021-00
0.55 kW MTF12A005-503-P12A-00
0.75 kW MTF12A007-503-P12A-00
1.1 kW MTF12A011-503-P12A-00
1.5 kW MTF12A015-503-P12A-00
2.2 kW
2
MTF12A022-503-P12A-00
3.0 kW MTF12A030-503-P12A-00
4.0 kW MTF12A040-503-P12A-00
SBus slave
Without 0.37 kW
1
MTF12A003-503-Z10A-00
MTA12A503-S021-00
0.55 kW MTF12A005-503-Z10A-00
0.75 kW MTF12A007-503-Z10A-00
1.1 kW MTF12A011-503-Z10A-00
1.5 kW MTF12A015-503-Z10A-00
2.2 kW
2
MTF12A022-503-Z10A-00
3.0 kW MTF12A030-503-Z10A-00
4.0 kW MTF12A040-503-Z10A-00
Function level
Fieldbus Unit power Size EBOX ABOX
Type Type
Option Integrated in Type
Internal braking resistor ABOX MTF11A003... to MTF11A015...:/BW1 (part number 1820 705 7)
ABOX MTF11A003... to MTF11A040...:/BW2 (part number 1820 754 5)
PROFIsafe extension with4 x FDI + 2 x FDO
EBOX /S11I am
PR
O FIsafe
B U S
P R O F I®
PROCESS FIELD BUS
Braking resistor MOVIFIT® type Part number Protective grid
BW200-003/K-1.5 MTF11A003... to MTF11A015...
0 828 291 9 0 813 152 X
BW200-005/K-1.5 0 828 283 8 -
BW150-010 0 802 285 2 -
BW100-003/K-1.5 MTF11A022... to MTF11A040...
0 828 293 5 0 813 152 X
BW100-005/K-1.5 0 828 286 2 -
BW068-010 0 802 287 9 -
BW068-020 0 802 286 0 -
Pi
fkVA
Hz
n
68 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
Screw fittings
Assigned motor The listed MOVIFIT® combinations are designed for connection to SEW-EURODRIVEDT/DV and DZ motors.A MOVIFIT® unit for connecting additional SEW-EURODRIVE motors must be orderedas shown in the following example:
Type of screw fitting Degree of protec-tion
Figure Contents Size Part number
Stainless steel screw plugs IP69K 10 pieces M16 x 1.5 1820 223 3
10 pieces M20 x 1.5 1820 224 1
10 pieces M25 x 1.5 1820 226 8
EMC cable gland (brass, nickel plated) IP66 10 pieces M16 x 1.5 1820 478 3
10 pieces M20 x 1.5 1820 479 1
10 pieces M25 x 1.5 1820 480 5
EMC cable gland (stainless steel) IP69K 10 pieces M16 x 1.5 1821 636 6
10 pieces M20 x 1.5 1821 637 4
10 pieces M25 x 1.5 1821 638 2
MOVIFIT® EBOX MTF11A003-503-E20A-0000 = DT/DV motors + DZ motors
01 = DT/DV motors + DAS motors
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 69
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
MOVIFIT® FC in connection with hybrid ABOX MTA...-S42.-...-00
EBOX ABOX
FC
MTF...-...-00MOVIFIT® FC with integrated
frequency inverter
Size 1
Size 2
MTA...-S42.-...-00Hybrid ABOX with M12 for I/Os
Function level
Fieldbus Unit power Size EBOX ABOX
Type Type
Classic PROFIBUS 0.37 kW
1
MTF11A003-503-P10A-00
MTA11A503-S421-00
0.55 kW MTF11A005-503-P10A-00
0.75 kW MTF11A007-503-P10A-00
1.1 kW MTF11A011-503-P10A-00
1.5 kW MTF11A015-503-P10A-00
2.2 kW
2
MTF11A022-503-P10A-00
3.0 kW MTF11A030-503-P10A-00
4.0 kW MTF11A040-503-P10A-00
PROFINET (Cu) 0.37 kW
1
MTF11A003-503-E20A-00
MTA11A503-S423-00
0.55 kW MTF11A005-503-E20A-00
0.75 kW MTF11A007-503-E20A-00
1.1 kW MTF11A011-503-E20A-00
1.5 kW MTF11A015-503-E20A-00
2.2 kW
2
MTF11A022-503-E20A-00
3.0 kW MTF11A030-503-E20A-00
4.0 kW MTF11A040-503-E20A-00
Pi
fkVA
Hz
n
70 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
Tech-nology
PROFIBUS 0.37 kW
1
MTF11A003-503-P11A-00
MTA11A503-S421-00
0.55 kW MTF11A005-503-P11A-00
0.75 kW MTF11A007-503-P11A-00
1.1 kW MTF11A011-503-P11A-00
1.5 kW MTF11A015-503-P11A-00
2.2 kW
2
MTF11A022-503-P11A-00
3.0 kW MTF11A030-503-P11A-00
4.0 kW MTF11A040-503-P11A-00
PROFINET (Cu) 0.37 kW
1
MTF11A003-503-E21A-00
MTA11A503-S423-00
0.55 kW MTF11A005-503-E21A-00
0.75 kW MTF11A007-503-E21A-00
1.1 kW MTF11A011-503-E21A-00
1.5 kW MTF11A015-503-E21A-00
2.2 kW
2
MTF11A022-503-E21A-00
3.0 kW MTF11A030-503-E21A-00
4.0 kW MTF11A040-503-E21A-00
EtherNet/IP (Cu)Modbus TCP (CU)
0.37 kW
1
MTF11A003-503-E31A-00
MTA11A503-S423-00
0.55 kW MTF11A005-503-E31A-00
0.75 kW MTF11A007-503-E31A-00
1.1 kW MTF11A011-503-E31A-00
1.5 kW MTF11A015-503-E31A-00
2.2 kW
2
MTF11A022-503-E31A-00
3.0 kW MTF11A030-503-E31A-00
4.0 kW MTF11A040-503-E31A-00
System PROFIBUS 0.37 kW
1
MTF11A003-503-P12A-00
MTA11A503-S421-00
0.55 kW MTF11A005-503-P12A-00
0.75 kW MTF11A007-503-P12A-00
1.1 kW MTF11A011-503-P12A-00
1.5 kW MTF11A015-503-P12A-00
2.2 kW
2
MTF11A022-503-P12A-00
3.0 kW MTF11A030-503-P12A-00
4.0 kW MTF11A040-503-P12A-00
SBus slave
Without 0.37 kW
1
MTF11A003-503-Z10A-00
MTA11A503-S421-00
0.55 kW MTF11A005-503-Z10A-00
0.75 kW MTF11A007-503-Z10A-00
1.1 kW MTF11A011-503-Z10A-00
1.5 kW MTF11A015-503-Z10A-00
2.2 kW
2
MTF11A022-503-Z10A-00
3.0 kW MTF11A030-503-Z10A-00
4.0 kW MTF11A040-503-Z10A-00
Function level
Fieldbus Unit power Size EBOX ABOX
Type Type
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 71
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
Screw fittings
Options
External braking resistors
Assigned motor The listed MOVIFIT® combinations are designed for connection to SEW-EURODRIVEDT/DV and DZ motors.A MOVIFIT® unit for connecting additional SEW-EURODRIVE motors must be orderedas shown in the following example:
Type of screw fitting Figure Contents Size Part number
EMC cable gland (brass, nickel plated) 10 pieces M16 x 1.5 1820 478 3
10 pieces M20 x 1.5 1820 479 1
10 pieces M25 x 1.5 1820 480 5
Option Integrated in Type
Maintenance switch ABOX MTA......-....-D01-00
Internal braking resistor ABOX MTF11A003... to MTF11A015...:/BW1 (part number 1820 705 7)
ABOX MTF11A003... to MTF11A040...:/BW2 (part number 1820 754 5)
PROFIsafe extension with4 x FDI + 2 x FDO
EBOX /S11I am
PR
O FIsafe
B U S
P R O F I®
PROCESS FIELD BUS
Braking resistor MOVIFIT® type Part number Protective grid
BW200-003/K-1.5 MTF11A003... to MTF11A015...
0 828 291 9 0 813 152 X
BW200-005/K-1.5 0 828 283 8 -
BW150-010 0 802 285 2 -
BW100-003/K-1.5 MTF11A022... to MTF11A040...
0 828 293 5 0 813 152 X
BW100-005/K-1.5 0 828 286 2 -
BW068-010 0 802 287 9 -
BW068-020 0 802 286 0 -
MOVIFIT® EBOX MTF11A003-503-E20A-0000 = DT/DV motors + DZ motors
01 = DT/DV motors + DAS motors
Pi
fkVA
Hz
n
72 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
MOVIFIT® FC in connection with hybrid ABOX MTA...-S52.-...-00
EBOX ABOX
FC
MTF...-...-00MOVIFIT® FC with integrated
frequency inverter
Size 1
Size 2
MTA...-S52.-...-00Hybrid ABOX with M12 for I/Os and bus
Function level
Fieldbus Unit power Size EBOX ABOX
Type Type
Classic PROFIBUS 0.37 kW
1
MTF11A003-503-P10A-00
MTA11A503-S521-00
0.55 kW MTF11A005-503-P10A-00
0.75 kW MTF11A007-503-P10A-00
1.1 kW MTF11A011-503-P10A-00
1.5 kW MTF11A015-503-P10A-00
2.2 kW
2
MTF11A022-503-P10A-00
3.0 kW MTF11A030-503-P10A-00
4.0 kW MTF11A040-503-P10A-00
DeviceNet 0.37 kW
1
MTF11A003-503-D10A-00
MTA11A503-S522-00
0.55 kW MTF11A005-503-D10A-00
0.75 kW MTF11A007-503-D10A-00
1.1 kW MTF11A011-503-D10A-00
1.5 kW MTF11A015-503-D10A-00
2.2 kW
2
MTF11A022-503-D10A-00
3.0 kW MTF11A030-503-D10A-00
4.0 kW MTF11A040-503-D10A-00
PROFINET (Cu) 0.37 kW
1
MTF11A003-503-E20A-00
MTA11A503-S523-00
0.55 kW MTF11A005-503-E20A-00
0.75 kW MTF11A007-503-E20A-00
1.1 kW MTF11A011-503-E20A-00
1.5 kW MTF11A015-503-E20A-00
2.2 kW
2
MTF11A022-503-E20A-00
3.0 kW MTF11A030-503-E20A-00
4.0 kW MTF11A040-503-E20A-00
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 73
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
Tech-nology
PROFIBUS 0.37 kW
1
MTF11A003-503-P11A-00
MTA11A503-S521-00
0.55 kW MTF11A005-503-P11A-00
0.75 kW MTF11A007-503-P11A-00
1.1 kW MTF11A011-503-P11A-00
1.5 kW MTF11A015-503-P11A-00
2.2 kW
2
MTF11A022-503-P11A-00
3.0 kW MTF11A030-503-P11A-00
4.0 kW MTF11A040-503-P11A-00
DeviceNet 0.37 kW
1
MTF11A003-503-D11A-00
MTA11A503-S522-00
0.55 kW MTF11A005-503-D11A-00
0.75 kW MTF11A007-503-D11A-00
1.1 kW MTF11A011-503-D11A-00
1.5 kW MTF11A015-503-D11A-00
2.2 kW
2
MTF11A022-503-D11A-00
3.0 kW MTF11A030-503-D11A-00
4.0 kW MTF11A040-503-D11A-00
PROFINET (Cu) 0.37 kW
1
MTF11A003-503-E21A-00
MTA11A503-S523-00
0.55 kW MTF11A005-503-E21A-00
0.75 kW MTF11A007-503-E21A-00
1.1 kW MTF11A011-503-E21A-00
1.5 kW MTF11A015-503-E21A-00
2.2 kW
2
MTF11A022-503-E21A-00
3.0 kW MTF11A030-503-E21A-00
4.0 kW MTF11A040-503-E21A-00
EtherNet/IP (Cu)Modbus TCP (CU)
0.37 kW
1
MTF11A003-503-E31A-00
MTA11A503-S523-00
0.55 kW MTF11A005-503-E31A-00
0.75 kW MTF11A007-503-E31A-00
1.1 kW MTF11A011-503-E31A-00
1.5 kW MTF11A015-503-E31A-00
2.2 kW
2
MTF11A022-503-E31A-00
3.0 kW MTF11A030-503-E31A-00
4.0 kW MTF11A040-503-E31A-00
System PROFIBUS 0.37 kW
1
MTF11A003-503-P12A-00
MTA11A503-S521-00
0.55 kW MTF11A005-503-P12A-00
0.75 kW MTF11A007-503-P12A-00
1.1 kW MTF11A011-503-P12A-00
1.5 kW MTF11A015-503-P12A-00
2.2 kW
2
MTF11A022-503-P12A-00
3.0 kW MTF11A030-503-P12A-00
4.0 kW MTF11A040-503-P12A-00
Function level
Fieldbus Unit power Size EBOX ABOX
Type Type
Pi
fkVA
Hz
n
74 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
Screw fittings
Options
External braking resistors
Assigned motor The listed MOVIFIT® combinations are designed for connection to SEW-EURODRIVEDT/DV and DZ motors.A MOVIFIT® unit for connecting additional SEW-EURODRIVE motors must be orderedas shown in the following example:
Type of screw fitting Figure Contents Size Part number
EMC cable gland (brass, nickel plated) 10 pieces M16 x 1.5 1820 478 3
10 pieces M20 x 1.5 1820 479 1
10 pieces M25 x 1.5 1820 480 5
Option Integrated in Type
Maintenance switch ABOX MTA......-....-D01-00
Internal braking resistor ABOX MTF11A003... to MTF11A015...:/BW1 (part number 1820 705 7)
ABOX MTF11A003... to MTF11A040...:/BW2 (part number 1820 754 5)
PROFIsafe extension with4 x FDI + 2 x FDO
EBOX /S11I am
PR
O FIsafe
B U S
P R O F I®
PROCESS FIELD BUS
Braking resistor MOVIFIT® type Part number Protective grid
BW200-003/K-1.5 MTF11A003... to MTF11A015...
0 828 291 9 0 813 152 X
BW200-005/K-1.5 0 828 283 8 -
BW150-010 0 802 285 2 -
BW100-003/K-1.5 MTF11A022... to MTF11A040...
0 828 293 5 0 813 152 X
BW100-005/K-1.5 0 828 286 2 -
BW068-010 0 802 287 9 -
BW068-020 0 802 286 0 -
MOVIFIT® EBOX MTF11A003-503-P10A-0000 = DT/DV motors + DZ motors
01 = DT/DV motors + DAS motors
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 75
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
MOVIFIT® FC in connection with hybrid ABOX MTA...-S62.-...-00
EBOX ABOX
FC
MTF...-...-00MOVIFIT® FC with integrated
frequency inverter
Size 1
Size 2
MTA...-S62.-...-00Hybrid ABOX with M12 for I/Os and
Push-Pull RJ45
Function level
Fieldbus Unit power Size EBOX ABOX
Type Type
Classic PROFINET (Cu) 0.37 kW
1
MTF11A003-503-E20A-00
MTA11A503-S623-00
0.55 kW MTF11A005-503-E20A-00
0.75 kW MTF11A007-503-E20A-00
1.1 kW MTF11A011-503-E20A-00
1.5 kW MTF11A015-503-E20A-00
2.2 kW
2
MTF11A022-503-E20A-00
3.0 kW MTF11A030-503-E20A-00
4.0 kW MTF11A040-503-E20A-00
Tech-nology
PROFINET (Cu) 0.37 kW
1
MTF11A003-503-E21A-00
MTA11A503-S623-00
0.55 kW MTF11A005-503-E21A-00
0.75 kW MTF11A007-503-E21A-00
1.1 kW MTF11A011-503-E21A-00
1.5 kW MTF11A015-503-E21A-00
2.2 kW
2
MTF11A022-503-E21A-00
3.0 kW MTF11A030-503-E21A-00
4.0 kW MTF11A040-503-E21A-00
EtherNet/IP (Cu)Modbus TCP (CU)
0.37 kW
1
MTF11A003-503-E31A-00
MTA11A503-S623-00
0.55 kW MTF11A005-503-E31A-00
0.75 kW MTF11A007-503-E31A-00
1.1 kW MTF11A011-503-E31A-00
1.5 kW MTF11A015-503-E31A-00
2.2 kW
2
MTF11A022-503-E31A-00
3.0 kW MTF11A030-503-E31A-00
4.0 kW MTF11A040-503-E31A-00
Pi
fkVA
Hz
n
76 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
Screw fittings
Options
External braking resistors
Assigned motor The listed MOVIFIT® combinations are designed for connection to SEW-EURODRIVEDT/DV and DZ motors.A MOVIFIT® unit for connecting additional SEW-EURODRIVE motors must be orderedas shown in the following example:
Type of screw fitting Figure Contents Size Part number
EMC cable gland (brass, nickel plated) 10 pieces M16 x 1.5 1820 478 3
10 pieces M20 x 1.5 1820 479 1
10 pieces M25 x 1.5 1820 480 5
Option Integrated in Type
Maintenance switch ABOX MTA......-....-D01-00
Internal braking resistor ABOX MTF11A003... to MTF11A015...:/BW1 (part number 1820 705 7)
ABOX MTF11A003... to MTF11A040...:/BW2 (part number 1820 754 5)
PROFIsafe extension with4 x FDI + 2 x FDO
EBOX /S11I am
PR
O FIsafe
B U S
P R O F I®
PROCESS FIELD BUS
Braking resistor MOVIFIT® type Part number Protective grid
BW200-003/K-1.5 MTF11A003... to MTF11A015...
0 828 291 9 0 813 152 X
BW200-005/K-1.5 0 828 283 8 -
BW150-010 0 802 285 2 -
BW100-003/K-1.5 MTF11A022... to MTF11A040...
0 828 293 5 0 813 152 X
BW100-005/K-1.5 0 828 286 2 -
BW068-010 0 802 287 9 -
BW068-020 0 802 286 0 -
MOVIFIT® EBOX MTF11A003-503-E20A-0000 = DT/DV motors + DZ motors
01 = DT/DV motors + DAS motors
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 77
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
2.15.6 Assignment of MOVIFIT® FC to SEW AC motors
DT/DV motors
DAS motors
NOTES• The following motor/brake combinations can be taken into operation with the corre-
sponding MOVIFIT® FC (see table below) as standard, i.e. if the MOVIFIT® FC isparameterized in Easy mode via DIP switches.
• Expanded parameter setting in Expert mode via fieldbus or diagnostic interface al-lows for startup of additional motor/brake combinations. Further information can befound in the following publications:– "MOVIFIT® Classic Function Level" manual– "MOVIFIT® Technology Function Level" manual
• In the function level "System", only the standard combinations can be taken intooperation (see table below).
Power MOVIFIT® FC Assigned motor and standard brake
Adapted combinations Combinations with increased short-term torque
� connection � connection � connection � connection
Motor Brake1) Motor Brake1) Motor Brake 1) Motor Brake 1)
0.37 kW MTF11A003-503-....-00 DT71 D4 BMG05 DR63 L4 BR03 DR63 L4 BR03 – –
0.55 kW MTF11A005-503-....-00 DT80 K4 BMG1 DT71 D4 BMG05 DT71 D4 BMG05 DR63 L4 BR03
0.75 kW MTF11A007-503-....-00 DT80 N4 BMG1 DT80 K4 BMG1 DT80 K4 BMG1 DT71 D4 BMG05
1.1 kW MTF11A011-503-....-00 DT90 S4 BMG2 DT80 N4 BMG1 DT80 N4 BMG1 DT80 K4 BMG1
1.5 kW MTF11A015-503-....-00 DT90 L4 BMG2 DT90 S4 BMG2 DT90 S4 BMG2 DT80 N4 BMG1
2.2 kW MTF11A022-503-....-00 DV100M4 BMG4 DT90 L4 BMG2 DT90 L4 BMG2 DT90 S4 BMG2
3.0 kW MTF11A030-503-....-00 DV100L4 BMG4 DV100M4 BMG4 DV100M4 BMG4 DT90 L4 BMG2
4.0 kW MTF11A040-503-....-00 DV112M4 BMG8 DV100L4 BMG4 DV100L4 BMG4 DV100M4 BMG4
1) Possible brake voltages 110 V, 230 V, 400 V
Power MOVIFIT® FC Assigned motor and standard brake
Adapted combinations Combinations with increased short-term torque
� connection � connection � connection � connection
Motor Brake1) Motor Brake1) Motor Brake 1) Motor Brake 1)
0.37 kW MTF11A003-503-....-01 DAS80N4 BR1 DAS80K4 BR1 DAS80K4 BR1 – –
0.55 kW MTF11A005-503-....-01 DAS90S4 BR2 DAS80N4 BR1 DAS80N4 BR1 DAS80K4 BR1
0.75 kW MTF11A007-503-....-01 DAS90L4 BR2 DAS90S4 BR2 DAS90S4 BR2 DAS80N4 BR1
1.1 kW MTF11A011-503-....-01 DAS100M4 BR2 DAS90L4 BR2 DAS90L4 BR2 DAS90S4 BR2
1.5 kW MTF11A015-503-....-01 DAS100L4 BR2 DAS100M4 BR2 DAS100M4 BR2 DAS90L4 BR2
2.2 kW MTF11A022-503-....-01 – – DAS100L4 BR2 DAS100L4 BR2 DAS100M4 BR2
3.0 kW MTF11A030-503-....-01 – – – – – – DAS100L4 BR2
4.0 kW MTF11A040-503-....-01 – – – – – – – –
1) Possible brake voltages BR1: 230 V, BR2: 230 V and 400 V
Pi
fkVA
Hz
n
78 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
2.15.7 Hybrid cable for connecting MOVIFIT® FC to motors
MOVIFIT® FC Hybrid cable Length Cable type Drive
ABOX
MTA...-S02.-...-00
MTA...-S42.-...-00
MTA...-S52.-...-00
MTA...-S62.-...-00
Part number DT71-90 (star): 0819 967 1Part number DT71-90 (delta): 0819 969 8Part number DV100 (star): 0819 970 1Part number DV100 (delta): 0819 874 8
variable A Motor with ISU4 plug connector
Part number: 0819 972 8 variable A • Motor with ASB4 plug connector
• Motor with ASB8 plug connector
Part number: 0819 875 6 variable A • Motor with AMB4 plug connector
• Motor with AMB8 plug connector
Part number: 0819 973 6 variable A Motor with APG4 plug connector
Part number: 0819 975 2 variable A Motor with cable glands
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 79
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Standard and Hybrid ABOXMOVIFIT®
MOVIFIT® FC Hybrid cable roll Cablelength
Cable type
Drive
ABOX
MTA...-S02.-...-00
MTA...-S42.-...-00
MTA...-S52.-...-00
MTA...-S62.-...-00
Part number: 0 818 736 3 (hybrid cable roll) 30 m A • Motor with cable glands• ASEPTIC DAS motor
Part number: 0 818 739 8 (hybrid cable roll) 100 m A • Motor with cable glands• ASEPTIC DAS motor
Part number: 1172 378 5 (cable roll) 30 m – External braking resistor
Maximum cable length between MOVIFIT® and external braking resistor: 15 m
Pi
fkVA
Hz
n
80 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Han-Modular® ABOXMOVIFIT®
2.16 Selection tables in connection with Han-Modular® ABOX2.16.1 Available combinations of MOVIFIT® MCMOVIFIT® MC in connection with Han-Modular® ABOX MTA...-H11.-...-00
Option
EBOX ABOX
MC
MTM...-...-00MOVIFIT® MC for controlling up to 3
MOVIMOT® drives
MTA...-H11.-...-00Han-Modular® ABOX with M12 for I/Os and bus
and with industrial connectors
Function level Fieldbus EBOX ABOX
Type Type
Classic PROFIBUS MTM11A000-P10A-00 MTA11A503-H111-M01-00
DeviceNet MTM11A000-D10A-00 MTA11A503-H112-M01-00
Technology PROFIBUS MTM11A000-P11A-00 MTA11A503-H111-M01-00
DeviceNet MTM11A000-D11A-00 MTA11A503-H112-M01-00
System PROFIBUS MTM11A000-P12A-00 MTA11A503-H111-M01-00
Option Integrated in Type
PROFIsafe extension with4 x FDI + 2 x FDO
EBOX /S11I am
PR
O FIsafe
B U S
P R O F I®
PROCESS FIELD BUS
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 81
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Han-Modular® ABOXMOVIFIT®
MOVIFIT® MC in connection with Han-Modular® ABOX MTA...-H21.-...-00
Option
EBOX ABOX
MC
MTM...-...-00MOVIFIT® MC for controlling up to 3
MOVIMOT® drives
MTA...-H21.-...-00Han-Modular® ABOX with M12 for I/Os, Push-Pull
RJ45 and industrial connectors
Function level Fieldbus EBOX ABOX
Type Type
Classic PROFINET (Cu) MTM11A000-E20A-00 MTA11A503-H213-M01-00
Technology PROFINET (Cu) MTM11A000-E21A-00 MTA11A503-H213-M01-00
EtherNet/IP (Cu)Modbus TCP (CU)
MTM11A000-E31A-00 MTA11A503-H213-M01-00
Option Integrated in Type
PROFIsafe extension with4 x FDI + 2 x FDO
EBOX /S11I am
PR
O FIsafe
B U S
P R O F I®
PROCESS FIELD BUS
Pi
fkVA
Hz
n
82 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Han-Modular® ABOXMOVIFIT®
2.16.2 Hybrid cable for connecting MOVIFIT® MC and MOVIMOT®
MOVIFIT® MC Hybrid cable Length Cable type
Drive
ABOX
MTA...-H21.-...-00 Part number: 1810 050 3 variable B MOVIMOT® with Plug connector AMA6
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 83
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Han-Modular® ABOXMOVIFIT®
2.16.3 Available combinations of MOVIFIT® SCMOVIFIT® SC in connection with Han-Modular® ABOX MTA...-H12.-...-00
EBOX ABOX
SC
MTS...-...-00MOVIFIT® SC
With integrated motor switch
MTA...-H12.-...-00Han-Modular® ABOX with M12 for I/Os and bus
and with industrial connectors
Function level Fieldbus Unit power EBOX ABOX
Type Type
Classic PROFIBUS 1.5 kW MTS11A015-503-P10A-00MTA11A503-H121-D01-00
4.0 kW MTS11A040-503-P10A-00
DeviceNet 1.5 kW MTS11A015-503-D10A-00MTA11A503-H122-D01-00
4.0 kW MTS11A040-503-D10A-00
Technology PROFIBUS 1.5 kW MTS11A015-503-P11A-00MTA11A503-H121-D01-00
4.0 kW MTS11A040-503-P11A-00
DeviceNet 1.5 kW MTS11A015-503-D11A-00MTA11A503-H122-D01-00
4.0 kW MTS11A040-503-D11A-00
System PROFIBUS 1.5 kW MTS11A015-503-P12A-00MTA11A503-H121-D01-00
4.0 kW MTS11A015-503-P12A-00
Pi
fkVA
Hz
n
84 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Han-Modular® ABOXMOVIFIT®
MOVIFIT® SC in connection with Han-Modular® ABOX MTA...-H22.-...-00
EBOX ABOX
SC
MTS...-...-00MOVIFIT® SC
With integrated motor switch
MTA...-H22.-...-00Han-Modular® ABOX with M12 for I/Os, Push-Pull
RJ45 and industrial connectors
Function level Fieldbus Unit power EBOX ABOX
Type Type
Classic PROFINET (Cu) 1.5 kW MTS11A015-503-E20A-00MTA11A503-H223-D01-00
4.0 kW MTS11A040-503-E20A-00
Technology PROFINET (Cu) 1.5 kW MTS11A015-503-E21A-00MTA11A503-H223-D01-00
4.0 kW MTS11A040-503-E21A-00
EtherNet/IP (Cu)Modbus TCP (CU)
1.5 kW MTS11A015-503-E31A-00MTA11A503-H223-D01-004.0 kW MTS11A040-503-E31A-00
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 85
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Han-Modular® ABOXMOVIFIT®
2.16.4 Hybrid cable for connecting MOVIFIT® SC to motors
MOVIFIT® SC Hybrid cable Length Cable type Drive
ABOX
MTA...-H12.-...-00
MTA...-H22.-...-00
Part number1810 096 1 variable A • Motor with ASB4 plug connector
• Motor with ASB8 plugconnector
Part number 1810 098 8 variable A • Motor with AMB4 plug connector
• Motor with AMB8 plug connector
Part number 1810 099 6 variable A Motor with APG4 plug connector
Pi
fkVA
Hz
n
86 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Han-Modular® ABOXMOVIFIT®
2.16.5 Available combinations of MOVIFIT® FCMOVIFIT® FC in connection with Han-Modular® ABOX MTA...-H12.-...-00
EBOX ABOX
FC
MTF...-...-00MOVIFIT® FC with integrated frequency
inverter
Size 1
Size 2
MTA...-H12.-...-00Han-Modular® ABOX with M12 for I/Os and bus
and with industrial connectors
Function level
Fieldbus Unit power Size EBOX ABOX
Type Type
Classic PROFIBUS 0.37 kW
1
MTF11A003-503-P10A-00
MTA11A503-H121-D01-00
0.55 kW MTF11A005-503-P10A-00
0.75 kW MTF11A007-503-P10A-00
1.1 kW MTF11A011-503-P10A-00
1.5 kW MTF11A015-503-P10A-00
2.2 kW
2
MTF11A022-503-P10A-00
3.0 kW MTF11A030-503-P10A-00
4.0 kW MTF11A040-503-P10A-00
DeviceNet 0.37 kW
1
MTF11A003-503-D10A-00
MTA11A503-H122-D01-00
0.55 kW MTF11A005-503-D10A-00
0.75 kW MTF11A007-503-D10A-00
1.1 kW MTF11A011-503-D10A-00
1.5 kW MTF11A015-503-D10A-00
2.2 kW
2
MTF11A022-503-D10A-00
3.0 kW MTF11A030-503-D10A-00
4.0 kW MTF11A040-503-D10A-00
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 87
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Han-Modular® ABOXMOVIFIT®
Options
Tech-nology
PROFIBUS 0.37 kW
1
MTF11A003-503-P11A-00
MTA11A503-H121-D01-00
0.55 kW MTF11A005-503-P11A-00
0.75 kW MTF11A007-503-P11A-00
1.1 kW MTF11A011-503-P11A-00
1.5 kW MTF11A015-503-P11A-00
2.2 kW
2
MTF11A022-503-P11A-00
3.0 kW MTF11A030-503-P11A-00
4.0 kW MTF11A040-503-P11A-00
DeviceNet 0.37 kW
1
MTF11A003-503-D11A-00
MTA11A503-H122-D01-00
0.55 kW MTF11A005-503-D11A-00
0.75 kW MTF11A007-503-D11A-00
1.1 kW MTF11A011-503-D11A-00
1.5 kW MTF11A015-503-D11A-00
2.2 kW
2
MTF11A022-503-D11A-00
3.0 kW MTF11A030-503-D11A-00
4.0 kW MTF11A040-503-D11A-00
System PROFIBUS 0.37 kW
1
MTF11A003-503-P12A-00
MTA11A503-H121-D01-00
0.55 kW MTF11A005-503-P12A-00
0.75 kW MTF11A007-503-P12A-00
1.1 kW MTF11A011-503-P12A-00
1.5 kW MTF11A015-503-P12A-00
2.2 kW
2
MTF11A022-503-P12A-00
3.0 kW MTF11A030-503-P12A-00
4.0 kW MTF11A040-503-P12A-00
Function level
Fieldbus Unit power Size EBOX ABOX
Type Type
Option Integrated in Type
Internal braking resistor ABOX MTF11A003... to MTF11A040...:/BW2 (part number 1820 754 5)
PROFIsafe extension with4 x FDI + 2 x FDO
EBOX /S11I am
PR
O FIsafe
B U S
P R O F I®
PROCESS FIELD BUS
Pi
fkVA
Hz
n
88 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Han-Modular® ABOXMOVIFIT®
External braking resistors
Assigned motor The listed MOVIFIT® combinations are designed for connection to SEW-EURODRIVEDT/DV and DZ motors.A MOVIFIT® unit for connecting additional SEW-EURODRIVE motors must be orderedas shown in the following example:
Braking resistor MOVIFIT® type Part number Protective grid
BW200-003/K-1.5 MTF11A003... to MTF11A015...
0 828 291 9 0 813 152 X
BW200-005/K-1.5 0 828 283 8 -
BW150-010 0 802 285 2 -
BW100-003/K-1.5 MTF11A022... to MTF11A040...
0 828 293 5 0 813 152 X
BW100-005/K-1.5 0 828 286 2 -
BW068-010 0 802 287 9 -
BW068-020 0 802 286 0 -
MOVIFIT® EBOX MTF11A003-503-P10A-0000 = DT/DV motors + DZ motors
01 = DT/DV motors + DAS motors
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 89
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Han-Modular® ABOXMOVIFIT®
MOVIFIT® FC in connection with Han-Modular® ABOX MTA...-H22.-...-00
EBOX ABOX
FC
MTF...-...-00MOVIFIT® FC with integrated frequency
inverter
Size 1
Size 2
MTA...-H22.-...-00Han-Modular® ABOX with M12 for I/Os, Push-Pull
RJ45 and industrial connectors
Function level
Fieldbus Unit power Size EBOX ABOX
Type Type
Classic PROFINET (Cu) 0.37 kW
1
MTF11A003-503-E20A-00
MTA11A503-H223-D01-00
0.55 kW MTF11A005-503-E20A-00
0.75 kW MTF11A007-503-E20A-00
1.1 kW MTF11A011-503-E20A-00
1.5 kW MTF11A015-503-E20A-00
2.2 kW
2
MTF11A022-503-E20A-00
3.0 kW MTF11A030-503-E20A-00
4.0 kW MTF11A040-503-E20A-00
Tech-nology
PROFINET (Cu) 0.37 kW
1
MTF11A003-503-E21A-00
MTA11A503-H223-D01-00
0.55 kW MTF11A005-503-E21A-00
0.75 kW MTF11A007-503-E21A-00
1.1 kW MTF11A011-503-E21A-00
1.5 kW MTF11A015-503-E21A-00
2.2 kW
2
MTF11A022-503-E21A-00
3.0 kW MTF11A030-503-E21A-00
4.0 kW MTF11A040-503-E21A-00
EtherNet/IP (Cu)Modbus TCP (CU)
0.37 kW
1
MTF11A003-503-E31A-00
MTA11A503-H223-D01-00
0.55 kW MTF11A005-503-E31A-00
0.75 kW MTF11A007-503-E31A-00
1.1 kW MTF11A011-503-E31A-00
1.5 kW MTF11A015-503-E31A-00
2.2 kW
2
MTF11A022-503-E31A-00
3.0 kW MTF11A030-503-E31A-00
4.0 kW MTF11A040-503-E31A-00
Pi
fkVA
Hz
n
90 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Han-Modular® ABOXMOVIFIT®
Options
External braking resistors
Assigned motor The listed MOVIFIT® combinations are designed for connection to SEW-EURODRIVEDT/DV and DZ motors.A MOVIFIT® unit for connecting additional SEW-EURODRIVE motors must be orderedas shown in the following example:
Option Integrated in Type
Internal braking resistor ABOX MTF11A003... to MTF11A040...:/BW2 (part number 1820 754 5)
PROFIsafe extension with4 x FDI + 2 x FDO
EBOX /S11I am
PR
O FIsafe
B U S
P R O F I®
PROCESS FIELD BUS
Braking resistor MOVIFIT® type Part number Protective grid
BW200-003/K-1.5 MTF11A003... to MTF11A015...
0 828 291 9 0 813 152 X
BW200-005/K-1.5 0 828 283 8 -
BW150-010 0 802 285 2 -
BW100-003/K-1.5 MTF11A022... to MTF11A040...
0 828 293 5 0 813 152 X
BW100-005/K-1.5 0 828 286 2 -
BW068-010 0 802 287 9 -
BW068-020 0 802 286 0 -
MOVIFIT® EBOX MTF11A003-503-E20A-0000 = DT/DV motors + DZ motors
01 = DT/DV motors + DAS motors
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 91
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Selection tables in connection with Han-Modular® ABOXMOVIFIT®
2.16.6 Assignment of MOVIFIT® FC to SEW AC motors
DT/DV motors
DAS motors
NOTES• The following motor/brake combinations can be taken into operation with the corre-
sponding MOVIFIT® FC (see table below) as standard, i.e. if the MOVIFIT® FC isparameterized in Easy mode via DIP switches.
• Expanded parameter setting in Expert mode via fieldbus or diagnostic interface al-lows for startup of additional motor/brake combinations. Further information can befound in the following publications:– "MOVIFIT® Classic Function Level" manual– "MOVIFIT® Technology Function Level" manual
• In the function level "System", only the standard combinations can be taken into op-eration (see table below).
Power MOVIFIT® FC Assigned motor and standard brake
Adapted combinations Combinations with increased short-term torque
� connection � connection � connection � connection
Motor Brake1) Motor Brake1) Motor Brake 1) Motor Brake 1)
0,37 kW MTF11A003-503-....-00 DT71 D4 BMG05 DR63 L4 BR03 DR63 L4 BR03 – –
0,55 kW MTF11A005-503-....-00 DT80 K4 BMG1 DT71 D4 BMG05 DT71 D4 BMG05 DR63 L4 BR03
0,75 kW MTF11A007-503-....-00 DT80 N4 BMG1 DT80 K4 BMG1 DT80 K4 BMG1 DT71 D4 BMG05
1,1 kW MTF11A011-503-....-00 DT90 S4 BMG2 DT80 N4 BMG1 DT80 N4 BMG1 DT80 K4 BMG1
1.5 kW MTF11A015-503-....-00 DT90 L4 BMG2 DT90 S4 BMG2 DT90 S4 BMG2 DT80 N4 BMG1
2,2 kW MTF11A022-503-....-00 DV100M4 BMG4 DT90 L4 BMG2 DT90 L4 BMG2 DT90 S4 BMG2
3,0 kW MTF11A030-503-....-00 DV100L4 BMG4 DV100M4 BMG4 DV100M4 BMG4 DT90 L4 BMG2
4,0 kW MTF11A040-503-....-00 DV112M4 BMG8 DV100L4 BMG4 DV100L4 BMG4 DV100M4 BMG4
1) Possible brake voltages 110 V, 230 V, 400 V
Power MOVIFIT® FC Assigned motor and standard brake
Adapted combinations Combinations with increased short-term torque
� connection � connection � connection � connection
Motor Brake1) Motor Brake1) Motor Brake 1) Motor Brake 1)
0,37 kW MTF11A003-503-....-01 DAS80N4 BR1 DAS80K4 BR1 DAS80K4 BR1 – –
0,55 kW MTF11A005-503-....-01 DAS90S4 BR2 DAS80N4 BR1 DAS80N4 BR1 DAS80K4 BR1
0,75 kW MTF11A007-503-....-01 DAS90L4 BR2 DAS90S4 BR2 DAS90S4 BR2 DAS80N4 BR1
1,1 kW MTF11A011-503-....-01 DAS100M4 BR2 DAS90L4 BR2 DAS90L4 BR2 DAS90S4 BR2
1.5 kW MTF11A015-503-....-01 DAS100L4 BR2 DAS100M4 BR2 DAS100M4 BR2 DAS90L4 BR2
2,2 kW MTF11A022-503-....-01 – – DAS100L4 BR2 DAS100L4 BR2 DAS100M4 BR2
3,0 kW MTF11A030-503-....-01 – – – – – – DAS100L4 BR2
4,0 kW MTF11A040-503-....-01 – – – – – – – –
1) Possible brake voltages BR1: 230 V, BR2: 230 V and 400 V
Pi
fkVA
Hz
n
92 Catalog – Drive System for Decentralized Installation
2 Selection tables in connection with Han-Modular® ABOXMOVIFIT®
2.16.7 Hybrid cable for connecting MOVIFIT® FC to motors
MOVIFIT® FC Hybrid cable Length Cable type Drive
ABOX
MTA...-H12.-...-00
MTA...-H22.-...-00
Part number1810 096 1 variable A • Motor with ASB4 plug connector
• Motor with ASB8 plug connector
Part number 1810 098 8 variable A • Motor with AMB4 plug connector
• Motor with AMB8 plug connector
Part number 1810 099 6 variable A Motor with APG4 plug connector
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 93
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Permitted designs with functional safetyMOVIFIT®
2.17 Permitted designs with functional safety2.17.1 MOVIFIT® MC
Only the following devices are permitted for use in applications with safe disconnectionof the drive according to stop category 0 or 1 in accordance with EN 60204-1, fail-safeprotection against restart according to EN 1037, and fulfillment of safety category 3 inaccordance with EN 954-1 and performance level 'd' according to EN ISO 13849-1.
2.17.2 MOVIFIT® FCOnly the following devices are permitted for use in applications with safe disconnectionof the drive according to stop category 0 or 1 in accordance with EN 60204-1, fail-safeprotection against restart according to EN 1037, and fulfillment of safety category 3 inaccordance with EN 954-1 and performance level 'd' according to EN ISO 13849-1.
MOVIFIT® MC
EBOX MTM1.A000-P1.A-00MTM1.A000-E..A-00MTM1.A000-D1.A-00
ABOX Standard ABOXMTA1.A-503-S011-M01-00MTA1.A-503-S012-M01-00MTA1.A-503-S013-M01-00
Hybrid ABOXMTA11A-503-S411-M01-00MTA11A-503-S413-M01-00MTA11A-503-S511-M01-00MTA11A-503-S512-M01-00MTA11A-503-S513-M01-00MTA11A-503-S613-M01-00
Han-Modular® ABOXMTA11A-503-H111-M01-00MTA11A-503-H213-M01-00MTA11A-503-H112-M01-00
NOTEImportant: This certification only applies to the safe disconnection of MOVIFIT® MC incombination with the safety- oriented MM C-503-00 drive system and its requirements.
MOVIFIT® FC
EBOX MOVIFIT® FC for DT/DV motorsMTF1.A...-503-P1.A-00MTF1.A...-503-E..A-00MTF1.A...-503-D1.A-00
MOVIFIT® FC for DAS motorsMTF1.A...-503-P1.A-01MTF1.A...-503-E..A-01MTF1.A...-503-D1.A-01
ABOX Standard ABOXMTA1.A-503-S021-...-00MTA1.A-503-S023-...-00MTA1.A-503-S022-...-00
Hybrid ABOXMTA11A-503-S421-...-00 MTA11A-503-S423-...-00 MTA11A-503-S521-...-00 MTA11A-503-S522-...-00MTA11A-503-S523-...-00MTA11A-503-S623-...-00
Han-Modular® ABOXMTA11A-503-H121-D01-00MTA11A-503-H223-D01-00MTA11A-503-H122-D01-00
Pi
fkVA
Hz
n
94 Catalog – Drive System for Decentralized Installation
2 Permitted designs with PROFIsafe option S11MOVIFIT®
2.18 Permitted designs with PROFIsafe option S11PROFIsafe option S11 is permitted for use in safety-oriented applications up to SIL3according to EN 61508, safety category 4 according to EN 954-1, and performancelevel 'e' according to EN ISO 13849-1.
2.18.1 MOVIFIT® MC with PROFIsafe option S11
2.18.2 MOVIFIT® FC with PROFIsafe option S11
NOTEImportant: The certification only applies to the safety-oriented PROFIsafe option S11.The safety-oriented rive function that can be implemented with this depends on therespective MOVIFIT® basic unit.
MOVIFIT® MC with PROFIsafe option S11
EBOX MTM1.A000-P1.A-00/S11MTM1.A000-E2.A-00/S11
ABOX Standard ABOXMTA1.A-503-S011-M01-00MTA1.A-503-S013-M01-00
Hybrid ABOXMTA11A-503-S411-M01-00MTA11A-503-S413-M01-00MTA11A-503-S511-M01-00MTA11A-503-S513-M01-00MTA11A-503-S613-M01-00
Han-Modular® ABOXMTA11A-503-H111-M01-00MTA11A-503-H213-M01-00
I am
PR
O FIsafe
B U S
P R O F I®
PROCESS FIELD BUS
MOVIFIT® FC with PROFIsafe option S11
EBOX MOVIFIT® FC for DT/DV motorsMTF1.A...-503-P1.A-00/S11 MTF1.A...-503-E2.A-00/S11
MOVIFIT® FC for DAS motorsMTF1.A...-503-P1.A-01/S11 MTF1.A...-503-E2.A-01/S11
ABOX Standard ABOXMTA1.A-503-S021-...-00MTA1.A-503-S023-...-00
Hybrid ABOXMTA11A-503-S421-...-00 MTA11A-503-S423-...-00MTA11A-503-S521-...-00MTA11A-503-S523-...-00MTA11A-503-S623-...-00
Han-Modular® ABOXMTA11A-503-H121-D01-00MTA11A-503-H223-D01-00
I am
PR
O FIsafe
B U S
P R O F I®
PROCESS FIELD BUS
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 95
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Dimension sheetsMOVIFIT®
2.19 Dimension sheets2.19.1 In connection with Standard and Hybrid ABOX (S01, S02, S41, S42, S51, S52, S61, S62)Size 1 (MOVIFIT® MC, MOVIFIT® SC and MOVIFIT® FC 0.37 to 1.5 kW)
62599AXX
32
8.8
30
2.8
min
. 4
0
min. 50
12
37
.9
15
14
0
28
0
334.4
66
66 179.7
25
.6
31
7.3
Z
Z
14
0
Pi
fkVA
Hz
n
96 Catalog – Drive System for Decentralized Installation
2 Dimension sheetsMOVIFIT®
Size 2 (MOVIFIT® FC 2.2 to 4 kW)
62600AXX
334.4
66
31
7.3
179.712
33
2.5
min
. 4
0
min. 50
Z
37
.91
5
14
0
28
0
66
25
.6
Z
14
0
Pi
fkVA
Hz
n
Catalog – Drive System for Decentralized Installation 97
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Dimension sheetsMOVIFIT®
2.19.2 In connection with Han-Modular® ABOX (H11, H12, H21, H22)Size 1 (MOVIFIT® MC, MOVIFIT® SC and MOVIFIT® FC 0.37 to 1.5 kW)
61062AXX
66
334.4
min
.10
0
35
7.5
33
2.4 3
16
.6
25
.62
80
min
.40
188.8
min.50
Pi
fkVA
Hz
n