MONTHLY QA AUTOMATED ANALYSIS OF QA TASKS PIPSPRO SOFTWARE

MONTHLY QA · 2020. 10. 6. · MONTHLY QA QC-3 PHANTOM CALIBRATED PHANTOM REF 71350 Used to test the image quality from electronic portal imaging devices (EPIDs). QCKV-1 PHANTOM CALIBRATED

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MONTHLY QA · 2020. 10. 6. · MONTHLY QA QC-3 PHANTOM CALIBRATED PHANTOM REF 71350 Used to test the image quality from electronic portal imaging devices (EPIDs). QCKV-1 PHANTOM CALIBRATED

MONTHLY QAA U T O M AT E D A N A LY S I S O F Q A T A S K S

PIPSPRO™ SOFTWARE

Page 2: MONTHLY QA · 2020. 10. 6. · MONTHLY QA QC-3 PHANTOM CALIBRATED PHANTOM REF 71350 Used to test the image quality from electronic portal imaging devices (EPIDs). QCKV-1 PHANTOM CALIBRATED

A N N U A L Q A

“PIPSpro software and phantoms are valuable

tools for streamlining over 30 of the TG-142

tests, automating data analysis, and providing

documentation of the test results. By providing

quantifiable and repeatable results, PIPSpro

makes it easier for our center to become

compliant with TG-142.”

R I C K B A K E R

P H Y S I C S A P P L I C AT I O N S S P E C I A L I S T

I O WA H E A LT H D E S M O I N E S

J O H N S T O D D A R D C A N C E R C E N T E R

TABLE II — MONTHLYMECHANICAL

• Light/radiation field coincidence• Jaw position indicators• Cross-hair centering

TABLE III — ANNUALMECHANICAL

• Collimator rotation isocenter• Gantry rotation isocenter• Couch rotation isocenter• Coincidence of radiation and mechanical

isocenter

TABLE V — MULTILEAF COLLIMATIONWEEKLY

• Qualitative test, aka “picket fence”MONTHLY

• Setting vs radiation field for two patterns• Travel speed• Leaf position accuracyANNUAL

• MLC transmission• Leaf position repeatability• MLC spoke shot• Coincidence of light field and x-ray field • Segmental IMRT • Moving window IMRT

TABLE VI — IMAGINGDAILY

• PLANAR KV AND MV (EPID) IMAGING

- Positioning/repositioning - Imaging and treatment coordinate

coincidence• CONE-BEAM CT (KV AND MV)

- Imaging and treatment coordinate coincidence

- Positioning/repositioningMONTHLY

• PLANAR MV IMAGING (EPID)

- Imaging and treatment coordinate coincidence

- Scaling- Spatial resolution- Contrast- Uniformity and noise

• PLANAR KV IMAGING

- Imaging and treatment coordinate coincidence

- Scaling- Spatial resolution- Contrast- Uniformity and noise

• CONE-BEAM CT (KV AND MV)

- Geometric distortion- Spatial resolution- Contrast- HU constancy- Uniformity and noise

O V E R 3 0 P R O C E D U R E S I N O N E E A S Y - T O - U S E P L A T F O R M

PIPSPRO™ SOFTWARE

www.standardimaging.com // +1 608 831 0025

Page 3: MONTHLY QA · 2020. 10. 6. · MONTHLY QA QC-3 PHANTOM CALIBRATED PHANTOM REF 71350 Used to test the image quality from electronic portal imaging devices (EPIDs). QCKV-1 PHANTOM CALIBRATED

M O N T H L Y Q A

• Simple, clean and consistent user interface

• Easy-to-read reports, charts, and graphs

• PDF and comma separated variable (CSV) results export

• Multiple open modules for streamlined workflow

• Physicist-controlled editor for creating testing baselines

• Tracking and trending for test results

• Quick Selects™ for organizing tests and accessing test results

• Automatic image compositing for EPID MLC QA and StarShot images

• Centralized database for easy configuration and accessibility to results

• Complete Varian and Elekta IMRT and VMAT logfile analysis

• Workflow automation - single click deployment results

• Now includes Stereotactic collimator rotation

CT IMAGING QA

Using cone beam or diagnostic images obtained

with any of the Catphan phantoms (503, 504,

600), PIPSpro automatically finds analysis

image slices and performs required TG-142 tests

(geometric distortion, spatial resolution, contrast,

HU constancy, uniformity and noise). Results

are colored green (“Pass”), amber (“Alert”), or red

(“Fail”) for easy viewing of status (this scheme is

used throughout PIPSpro).

B y a u t o m a t i c a l l y i d e n t i f y i n g a n a l y s i s

r e g i o n s , s u b j e c t i v i t y i s r e d u c e d a n d

r e s u l t s c o n s i s t e n c y i s i m p r o v e d .

A U T O M AT I C

R E G I O N

I D E N T I F I C AT I O N

PLANAR IMAGING QA

PIPSpro kV planar imaging QA uses images

obtained with Standard Imaging’s QC-kV1

phantom or Leeds Test Objects’ TOR CDR

phantom. Testing is supported for kV imagers

integrated with linear accelerators as well as

images from ExacTrac, Cyberknife, and C-Arms.

EPID MV planar imaging QA uses Standard

Imaging’s calibrated QC-3 phantom.

TG-142 MADE EASYD E S I G N E D WI T H A CO NVE N I E N T A N D O PT I M I Z E D WO R K F LOW I N M I N D

www.standardimaging.com // +1 608 831 0025

Page 4: MONTHLY QA · 2020. 10. 6. · MONTHLY QA QC-3 PHANTOM CALIBRATED PHANTOM REF 71350 Used to test the image quality from electronic portal imaging devices (EPIDs). QCKV-1 PHANTOM CALIBRATED

M O N T H L Y Q A

W I N S T O N - L U T Z C U B E

MACHINE QAQ U I C K , E A S Y , P R E C I S E

RADIATION LIGHT FIELD ANALYSIS

PIPSpro uses a single image taken with custom

phantoms (FC-2, Center Marker) to calculate:

• Radiation and light field coincidence

• Radiation and crosshair displacement

• Light field and crosshair displacement

• Jaw position measurements

• Light field rotation

STARSHOT ANALYSIS

PIPSpro’s StarShot module uses EPID MV or

film images to measure rotational deviations

in gantry, collimator, and couch mechanical

isocenters. Results are expressed as the

minimum diameter containing all spokes

at the central point of intersection.

DAILY IGRT QA TRACKING

Use the Standard Imaging MIMI (Multi-Image

Modality Isocentricity) phantom with image

registration software to calculate known

3D (x, y, z) and 6D (add couch pitch, yaw and roll)

offsets. PIPSpro allows you to record your daily

offsets and track and trend your results.

STEREOTACTIC 3D

Use Standard Imaging’s Winston-Lutz phantom

to measure the difference between the radiation

isocenter and the mechanical isocenter for a

linear accelerator. A number of images are taken

with your portal imager using fixed angles or

angles of your choice.

• Automatically load and analyze any images,

including DICOM images, for cones or MLC’s.

• Automatically get 2D radiation/mechanical

offsets for each image.

• Automatically get an optimal 3D offset to

correct patient offset errors.

• 3D analysis with x, y, z results that help you

improve patient positioning.

UPLOAD RESULTS TO QA PILOT

PIPSpro QA Portal to automatically upload

test results to Standard Imaging’s QA Pilot QA

database software

www.standardimaging.com // +1 608 831 0025

Page 5: MONTHLY QA · 2020. 10. 6. · MONTHLY QA QC-3 PHANTOM CALIBRATED PHANTOM REF 71350 Used to test the image quality from electronic portal imaging devices (EPIDs). QCKV-1 PHANTOM CALIBRATED

M O N T H L Y Q A

PIPSpro MLC QA gives you actionable,

quantitative results that allow you to track and

trend all TG-142 requirements, delivering critical

information that may indicate an impending

MLC failure or indicate the need to recalibrate

your machine for the best possible clinical

outcomes. Step & Shoot and VMAT parameters

are tested in any direction using MLC leaf pattern

files (*.mlc, *.dva, *.efs).

. ”

S H A N N O N H O L M E S , P H . D .

M E D I C A L P H Y S I C I S T

S TA N D A R D I M A G I N G

“ P I P S p r o i s t h e f i r s t c o m m e r c i a l

m a c h i n e Q A s o f t w a r e t o d e t e r m i n e

l e a f s p e e d l o s s . S y s t e m s t h a t r e p o r t

o n l y m a x i m u m a n d m e a n l e a f s p e e d

c a n n o t b e u s e d t o c a l c u l a t e l e a f

s p e e d l o s s , a s r e q u i r e d b y T G - 1 4 2

SIM

PL

EC

OM

PL

EX

I n s i m p l e l e a f s p e e d t e s t s , a l l

l e a v e s t r a v e l t o g e t h e r

I n c o m p l e x l e a f s p e e d t e s t s ,

e v e r y o t h e r l e a f m o v e s ,

m a x i m i z i n g i n t e r - l e a f f r i c t i o n

Image-Based Logfile-Based

Ada

pted

from

TG

-14

2, T

AB

LE V

. Mul

tilea

f col

limat

ion

Matched Segments, aka “Picket Fence” Setting vs radiation field for two patterns (non-IMRT) Travel speed – leaf speed loss (IMRT)* Leaf position accuracy (IMRT) Average of leaf and interleaf transmission, all energies Leaf position repeatability* MLC spoke shot Coincidence of light field and x-ray field, all energies Segmental IMRT (step and shoot) test Moving window IMRT (four cardinal gantry angles)

* With logfile-based analysis, PIPSpro is the only commercial software solution able to measure quantitative leaf speed loss and leaf position repeatability.

COMPLETE MLC QACOVE R A L L TG -1 42 M LC QA T E STS WI T H E PI D I M AG E S A N D LO G F I L E S

www.standardimaging.com // +1 608 831 0025

Page 6: MONTHLY QA · 2020. 10. 6. · MONTHLY QA QC-3 PHANTOM CALIBRATED PHANTOM REF 71350 Used to test the image quality from electronic portal imaging devices (EPIDs). QCKV-1 PHANTOM CALIBRATED

M O N T H L Y Q A

QC-3 PHANTOMC A L I B R A T E D P H A N T O M

R E F 7 1 3 5 0

Used to test the image quality from electronic

portal imaging devices (EPIDs).

QCKV-1 PHANTOMC A L I B R A T E D P H A N T O M

R E F 7 1 4 5 1

Ideal for kV imaging systems, including Varian,

Elekta, BrainLAB and Cyberknife.

FC-2 PHANTOMR E F 7 2 1 8 7

For performing the radiation field vs. light field

test and jaw position testing

CENTER MARKER PHANTOMR E F 7 2 2 47

For performing the radiation field vs. light field

test and jaw position testing

CATPHANP U R C H A S E D T H R O U G H

Y O U R L I N A C V E N D O R

Compatible with model 503, 504, 600 and

604 phantoms

PIPSPRO SOFTWARE/COMPUTER REQUIREMENTSOperating System — Windows® 10 Professional, 64 bit recommendedProcessor — Dual Core, 1 GHz; Quad Core, 2 GHz RecommendedMemory — 32-bit OS: 2 GB, 4 GB Recommended 64-bit OS: 4 GB, 8 GB RecommendedRuntime Environment — .NET 4.5.2Hard Drive — 32 GB or greater, 3 GB free space for software setup.

Sufficient space to store input image and/or MLC Log files. 5 GB free space if setting up a local copy of SQL Server Express; 25% free space recommended.

Screen Resolution — 1600×900 (16:9) or higher, 16-bit HiColor or greaterOptical Drive — Digital Versatile Disc(DVD)Virtual Machines — Must support WMI (Windows Management Instrumentation)Database Management — SQL Server 2014 minimum recommendedConnectivity — IPv4 LAN, 100 Mbit/s or greater

Windows® is a registered trademark of Microsoft Corporation.

PIPSpro has streamlined our Monthly QA process. It has made

the daunting tasks in TG142 manageable. We currently use it

for an Elekta Synergy and image quality for our x-rays on our

3 IBA Proton treatment rooms.”

B E N R O B I S O NMedical PhysicistProvision Radiation Therapy

PHANTOMS

www.standardimaging.com // +1 608 831 0025

Page 7: MONTHLY QA · 2020. 10. 6. · MONTHLY QA QC-3 PHANTOM CALIBRATED PHANTOM REF 71350 Used to test the image quality from electronic portal imaging devices (EPIDs). QCKV-1 PHANTOM CALIBRATED

M O N T H L Y Q A

www.standardimaging.com800-261-4446 . ph 608-831-0025 . fax 608-831-2202 3120 Deming Way Middleton WI 53562 USA

© 2020 Standard Imaging, Inc. 1251-32 (9.20)