7
.. . . $P ( ra m ErMaam m m m%TJJ'a Carolina Power & Light Company cc1cta;zrm nnsintzirma Brunswick Nuclear Plant P. O. Box 10429 Southport, NC 28461-0429 July 6, 1993 FILE: B09-13510C BSEP/93-0105 U. S. Nuclear Regulatory Commission Washington, DC 20555 Attn: Document Control Desk BRUNSWICK STEAM ELECTRIC PLANT UNITS 1 AND 2 DOCKET NOS. 50-325 AND 50-324 LICENSE NOS. DPR-71 AND DPR-62 MONTHLY OPERATING REPORT Gentlemen: In accordance with Technical Specification 6.9.1.11 for the Brunswick Steam Electric Plant, Units 1 and 2, Carolina Power & Light Company herewith submits the report of operating statistics and shutdown experience for the moath of June 1993. Very truly yours, W J, . M. Brown, Plant Manager - Unit 1 runswick Nuclear Plant RHR/bc MSC/93-8524 Enclosures cc: Mr. R. A. Anderson Mr. R. G. Oehl Mr. T. C. Bell Mr R. M. Parsons Mr. R. M. Coats Mr. R. L. Prevatte Mr. S. D. Ebneter Mr. E. Scott Mr. P S. Gore Mr. M. S. Staton Ms. E. M. Harrelson Ms. T. A. Ward Mr. M. D. Hill Mr. C. C. Warren Mr. C. S. Hinnant Mr. D. B. Waters Mr. N. B. Le Mr. F Yost Ms Peggy Morris INPO Mr. W. R. Murray Regulatory Compliance (Document File) 19001E ~ ~+ 9307160273 930630 PDR ADOCK 05000324 3 R PDR . s -. __ __

Monthly operating repts for June 1993 for Brunswick Steam ... · Electric Plant, Units 1 and 2, Carolina Power & Light Company herewith submits the report of operating statistics

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Monthly operating repts for June 1993 for Brunswick Steam ... · Electric Plant, Units 1 and 2, Carolina Power & Light Company herewith submits the report of operating statistics

.. ..

$P (ra m ErMaam m m m%TJJ'aCarolina Power & Light Companycc1cta;zrm nnsintzirma

Brunswick Nuclear PlantP. O. Box 10429

Southport, NC 28461-0429July 6, 1993

FILE: B09-13510CBSEP/93-0105

U. S. Nuclear Regulatory CommissionWashington, DC 20555Attn: Document Control Desk

BRUNSWICK STEAM ELECTRIC PLANT UNITS 1 AND 2DOCKET NOS. 50-325 AND 50-324

LICENSE NOS. DPR-71 AND DPR-62MONTHLY OPERATING REPORT

Gentlemen:

In accordance with Technical Specification 6.9.1.11 for the Brunswick SteamElectric Plant, Units 1 and 2, Carolina Power & Light Company herewith submitsthe report of operating statistics and shutdown experience for the moath ofJune 1993.

Very truly yours,

WJ, . M. Brown, Plant Manager - Unit 1runswick Nuclear Plant

RHR/bcMSC/93-8524

Enclosures

cc: Mr. R. A. Anderson Mr. R. G. OehlMr. T. C. Bell Mr R. M. Parsons

Mr. R. M. Coats Mr. R. L. Prevatte

Mr. S. D. Ebneter Mr. E. Scott

Mr. P S. Gore Mr. M. S. Staton

Ms. E. M. Harrelson Ms. T. A. WardMr. M. D. Hill Mr. C. C. WarrenMr. C. S. Hinnant Mr. D. B. Waters

Mr. N. B. Le Mr. F YostMs Peggy Morris INPOMr. W. R. Murray Regulatory Compliance (Document File)

19001E~ ~+9307160273 930630

PDR ADOCK 05000324 3

R PDR. s-.

__ __

Page 2: Monthly operating repts for June 1993 for Brunswick Steam ... · Electric Plant, Units 1 and 2, Carolina Power & Light Company herewith submits the report of operating statistics

LP&L CO PLANT PERFORMANCE DATA SYSTEM PAGE 1'RWi DATE 07/01/93 APPENDIX B - AVERAGE DAILY POWER LEVEL RPD39-000RUN TIME '15:16:21 BRUNSWICK UNIT 1

DOCKET NO. 050-0325COMPLETED BY RONALD RUMPLETELEPHONE (919)457-2752

JUNE 1993

DAY AVG. DAILY POWER LEVEL DAY AVG. DAILY POWER LEVEL(MWE-NET) (MWE-NET)

1 -7 17 -6

2 -7 18 -6

3 -7 19 -6

4 -7 20 c

5 -7 21 -6

6 -7 22 -6I

7 -6 23 -6 j

8 -5 24 -6

9 -6 25 -6

10 -6 26 -6|

11 -6 27 -6

12 -6 28 -6

13 -6 29 -6

16 -6 30 -5

15 -6

16 -6

1.16 - 8

'

-. - .

Page 3: Monthly operating repts for June 1993 for Brunswick Steam ... · Electric Plant, Units 1 and 2, Carolina Power & Light Company herewith submits the report of operating statistics

i

*CP&L*CO PLANT PERFORMANCE DATA SYSTEM PAGE 1 4

RUN DATE 07/06/93 OPERATING DATA REPORT RPD36-000ERUN TIME ' 15:41:27 BRUNSWICK UNIT 1

DOCKET NO.- 050-0325COMPLETED BY RONALD RUMPLE

OPERATING STATUS TELEPHONE (919)457-2752_______________________________

1. UNIT NAME: BRUNSWICK UNIT 1 NOTES2. REPORTING PERIOD: JUNE 933. LICENSED THERMAL POWER (MWT): 24364. NAMEPLATE RATING (GROSS MWE): 867.05. DESIGN ELECTRICAL RATING (NET MWE) : 821.06. MAX DEPENDABLE CAPACITY (GROSS MWE): 791.07. MAX DEPENDABLE CAPACITY (NET MWE) : 767.0 -------------------------------

8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THRU 7) SINCE LAST REPORT,GIVE REASONS:

9. POWER LEVEL TO WHICH RESTRICTED IF ANY (NET MWE) :10. REASONS FOR RESTRICTION IF ANY:

THIS YR TO CUMULMONTH DATE ATIVE

11. HOURS IN REPORTING PERIOD 720.00 4343.00 142775.0012. NUMBER OF HOURS REACTOR CRITICAL .00 .00 87881.32 '

13. REACTOR RESERVE SHUTDOWN HRS .00 .00 1647.10'

14. HOURS GENERATOR ON LINE .00 .00 84201.3715. UNIT RESERVE SHUTDOWN HOURS .00 .00 .00 .

16. GROSS THERMAL ENERGY GEN. (MWH) .00 .00- 183021943.7017. GROSS ELEC. ENERGY GEN. (MWh) .00 .00 60019285.0018. NET ELEC. ENERGY GENERATED (MWH) -4295.00 -36452.00 57680754.00- -

19. UNIT SERVICE FACTOR .00 .00 58.9720. UNIT AVAILABILITY FACTOR .00 .00 58.9721. UNIT CAP. FACTOR (USING MDC NET) .78 -1.09 51.3722. UNIT CAP. FACTOR (USING DER NET) .73 -1.02 49.21 *

23. UNIT FORCED OUTAGE RATE .00 .00 16.0724. SHUTDOWNS SCHED. OVER NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH): !

t

25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF START UP: 9/23/9326. UNITS IN TEST STATUS (PRIOR TO COMMERCIAL OPERATION): FORECAST ACHIEVED

INITIAL CRITICALITY -------- --------

e r

*

.o L ' INITIAL ELECTRICITY, -------- --------t*

COMMERCIAL OPERATION h-------- --------

1.16 - 9

;

. . .. - _ _ . - _ - - -.

Page 4: Monthly operating repts for June 1993 for Brunswick Steam ... · Electric Plant, Units 1 and 2, Carolina Power & Light Company herewith submits the report of operating statistics

i:>- , ! , !

| ;-

.-_'

..

.

OT c.R -

IE .

tL 3. 3N aEO 1

a 8 -

TC e rdr~ 9 . mCN g o o 1 eAE a e fffE 2t

R t d o EA2IER u o s sE30VU o C nntI01 .IC ooe 8 - ITE g t ii em GVn n tth odee CR

i

r ur f aUo -2 E a casrrRn~ .

1 lp 5 RT l

RN e c ray dNim /x 3 u 2 OE u o tpren t

5 c 9 R - CV f m setl arcE e o nrnit ee9 72

1 d5 &R r C I p e f S p5.m .

3 PE l

' .0 s l 4

5 rly a -- n S a -

-0 u n 9 U nu o 1 A n -0 B J R 9 C o .

N 5.

Y

.

B ytT rn

JE DE N) t e .

5 Z nvm3VM EN E( ZA TO N eEo8 b.ZTN - EH O r9E Z aef1 3E LP P D Z

KTEPE M t e - 1O Z ase5CITML OCONAOE C dnl 0 mDUDCT r ei8 . e

cf.d2Iof 2tf oi

E :

nn Ra1 . ;L) r0D eU d oorEd I

C o iioL nGVC ttf( aE)

Z ca tR n ,M4 Zm urstSUoE( ratr NiT

S t t peoE tY s seepErc

5 y nrheEeeS - SI.N psRI pS

OI

T :

C . 4J E OD'3 E NTE9 S m sR9 N NT A a n

E /1 E R rso-V NR C O mcniE asotEe [L' E r i c-PWn

Ou R cct u -

PJ Siadt ue

D ll anr. N aami r

AH N uuotdeT W) nntnah

FO3 aauootS@N OD( MMACLO -W!O DGR dDT ONO 6 o .TR HIT hUO TTC t - - - - - -HP ETA eSE MUE M 123456

R HRT SI

N.U

: ..

) 3 .

2 ,(

- &n .t.

Rlu ia r ) -

N C s oO e e gi rS r t nt o -

AE r nner

ian .

i o iivea amiF e nratl l

.c yoTxaa p .

t) ngri Ern) xN nnanotr tone

.

O )S 0 mael aitsitaeinit coesii(

I R ol tel rannal rT U 0 ipnuut reirpeARO 2 uxif gsecmexh .

UH 7 q e a e e e pi d p e tD( E(MRRrOLAO(O .

nos .

- - ---

a - - - - -) e1 RA BCD E FG H( .

5E .

P ,Y

2._T :

-de

8E 0

. l

duT 3 edA 0 ce

.

D 3 rh ._.9 oc ._

FS _o __c - -y

2 TF5.

00O _-N -39

: _1 .

-

4 + i4|| ; ; : i! h !

Page 5: Monthly operating repts for June 1993 for Brunswick Steam ... · Electric Plant, Units 1 and 2, Carolina Power & Light Company herewith submits the report of operating statistics

- ,.

'CP&L'CO PLRNT PERFORMANCE DATA SYSTEM 'PAGE 2

RUN DATE' 07/01/93 APPENDIX B - AVERAGE DAILY POWER LEVEL RPD39-000 '

RUN TIME * 15:16:21 BRUNSWICK UNIT 2

DOCKET NO. 050-0324COMPLETED BY RONALD RUMPLETELEPHONE (919)457-2752

JUNE 1993

DAY AVG. DAILY POWER LEVEL DAY AVG. DAILY POWER LEVEL(MWE-NET) (MWE-NET)

1 770 17 768,

2 772 18 768

3 771 19 768

4 770 20 763

5 770 21 767

6 768 22 768

7 773 23 767

8 772 24 769

9 769 25 770,

10 769 26 769

11 767 27 764

12 764 28 766

13 480 29 766

14 765 30 766

15 767 ,

16 768

.

I

1.16 - 8

_ , - _ - __

Page 6: Monthly operating repts for June 1993 for Brunswick Steam ... · Electric Plant, Units 1 and 2, Carolina Power & Light Company herewith submits the report of operating statistics

r

' CP EL * CO PLANT PERFORMANCE DATA SYSTEM PAGE 2RUN DATE 07/01/93 OPERATING DATA REPORT RPD36-000 ;

RUN TIME ' 15:16:22 BRUNSWICK UNIT 2

DOCKET NO. 050-0324COMPLETED BY RONALD RUMPLE

OPERATING STATUS TELEPHONE (919)457-2752_______________________________

1. UNIT NAME: BRUNSWICK UNIT 2 NOTES2. REPORTING PERIOD: JUNE 93

.

3. LICENSED THERMAL POWER (MWT): 24364. NAMEPLATE RATING-(GROFfi MWE): 867.0

. NET MWE): 821.0(5. DESIGN ELECTRICAL RATING6. MAX DEPENDABLE CAPACITY (GROSS MWE): 782.07. MAX DEPENDABLE CAPACITY (NET MWE): 754.0 -------------------------------

8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THRU 7) SINCE LAST REPORT,GIVE REASONS:

9. POWER LEVEL TO WHICH RESTRICTED IF ANY (NET MWE):10. REASONS FOR RESTRICTION IF ANY:

THIS YR TO CUMULMONTH DATE ATIVE

11. HOURS IN REPORTING PERIOD 720.00 4343.00 154799.0012. NUMBER OF HOURS REACTOR CRITICAL 720.00 1498.30 93589.68'13. REACTOR RESERVE SHUTDOWN HRS .00 .00 .0014. HOURS GENERATOR ON LINE 720.00 1108.78 88263.4515. UNIT RESERVE SHUTDOWN HOURS .00 .00 .0016. GROSS THERMAL ENERGY GEN. (MWH) 1731855.69 2304814.58 186431669.4417. GROSS ELEC. ENERGY GEN. (MWH) 561890.00 735025.00 60285494.00

,

18. NET ELEC. ENERGY GENERATED (MWH) 546103.00 682540.00 57730100.00 !

19. UNIT SERVICE FACTOR 100.00 25.53 57.02'

20. UNIT AVAILABILITY FACTOR 100.00 25.53 57.0221. UNIT CAP. FACTOR (USING MDC NET) 100.59 20.84 47.5122. UNIT CAP. FACTOR (USING DER NET) 92.38 19.14 45.4223. UNIT. FORCED OUTAGE RATE .00 .00 13.3624. SHUTDOWNS SCHED. OVER NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH):.

!

|

25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF START UP: -j26. UNITS IN TEST STATUS { PRIOR TO COMMERCIAL OPERATION): FORECAST ACHIEVED .i

INITIAL CRITICALI7Y -------- --------

INITIAL ELECTRICIfY -------- --------

COMMERCIAL OPERATION -------- --------

|

1.16 - 9

. ._ - . , ,

Page 7: Monthly operating repts for June 1993 for Brunswick Steam ... · Electric Plant, Units 1 and 2, Carolina Power & Light Company herewith submits the report of operating statistics

<

'

'

.

'.

.

1)'

.,

V .

DOCKET NO. 050-0324, .

UNIT NAME Brumwitt ? ,

DATE Juiy 1993,

COMPLETED BY Ronald RumleTELEPHONE 919-457-2/52,

UNIT 5HUTOOWNS AND POWER REDUCTICNSREPORT MONTH June 1993

;

METHOD OF LICENSEEDURATION SHUTTING DOWN EVENT SYSTEM CODE CCMPONENT CAUSE & CORRECTIVE ACTION TO

NO. CATE TYPE (1) (HOURS) REASON (2) REACTOR (3) REPORT NO. (4) CCOE (5) PREVENT RECURRENCE

93-012 930612 S 24.83 B 5 N/A SN LCV Reduced power to performcentrol valve testing andmaintenance on various BOP4

. equipment. Repaired 4A| Feedwater Heater Dump Valve

2-HD-LV-75. Trouble wascaused by the valve stembacking out of the splitcoupling which was loose.This caused the valve streketo be shorter than requiredby 3/4" Tightened thesplit coup?ing, set valvestroke, and returned the

valve to functional status.

*This event was previously 92-025.

1: h 2: Reason 3: Method 4: System Code: 5, Cormerent CodeF - Forced A- Equipment Failure 1- Manual Instruction for Instructions for5 - Scheduled (explain) 2- Manual Scram preparation of data entry preparation of data

B- Maintenance or test 3- Automatic scram sheets for Licensee Event entry sheets for LERC- Refueling 4- Continuations Report (LEO) file from file from IEEED- Regulatory 5 Load reductions IEEE Standard 805-1983. Standard 803A-1983.

4 restriction 6- Other per NUREG-1022. per NUREG-1022.! E- Operator Training & Section VI. Item 13.b Section VI. Item 13.c

License Examination.. F- AdministrativeI G- Operational error

(explain)H- Other (explain)

1-

,