24
User Guide - English FUJITSU Software ServerView Suite Monitoring FibreCAT SX systems with ServerView Operations Manager Edition February 2018

Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

User Guide - English

FUJITSU Software ServerView Suite

Monitoring FibreCAT SX systems with ServerView Operations Manager

Edition February 2018

Page 2: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

Comments… Suggestions… Corrections…The User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our documentation to suit your individual needs.

Feel free to send us your comments by e-mail to [email protected].

Certified documentation according to DIN EN ISO 9001:2008To ensure a consistently high quality standard anduser-friendliness, this documentation was created tomeet the regulations of a quality management system which complies with the requirements of the standardDIN EN ISO 9001:2008.

cognitas. Gesellschaft für Technik-Dokumentation mbHwww.cognitas.de

Copyright and Trademarks

Copyright 2009 FUJITSU LIMITED

All rights reserved.Delivery subject to availability; right of technical modifications reserved.

All hardware and software names used are trademarks of their respective manufacturers.

Page 3: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

Contents

1 Monitoring FibreCAT SX systems with ServerView Operations Manager . . . . . . . . . . . . . . . . . . . . . . . 5

1.1 Preparing for FibreCAT SX monitoring . . . . . . . . . . . . . 61.1.1 Software requirements . . . . . . . . . . . . . . . . . . . . . . 71.1.1.1 Software required on the management server (Windows) . . . 71.1.1.2 Software required on the FibreCAT SX system . . . . . . . . 71.1.2 Installing the software . . . . . . . . . . . . . . . . . . . . . . . 81.1.3 Activities after installation . . . . . . . . . . . . . . . . . . . . . 9

1.2 Monitoring FibreCAT SX systems with the ServerView Operations Manager . . . . . . . . . . . . . . . . . . . . . . 10

1.2.1 Integrating FibreCAT SX in ServerView alarm management . . 101.2.2 Showing FibreCAT SX systems in the Operations Manager

server list . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111.2.3 Showing detailed information on the FibreCAT SX system . . . 13

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

FibreCAT SX

Page 4: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system
Page 5: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

1 Monitoring FibreCAT SX systems with ServerView Operations Manager

FibreCAT SX is an extensive Fibre Channel storage system that can be used both as a directly connected system and in Storage Area Network (SAN) environments. The advanced software functions permit uninterrupted operation with the very highest levels of availability and at the same time offer disaster protection.

The strengths of FibreCAT SX systems lie in their scalability and high levels of reliability. They enable tight integration and smooth interaction between servers and storage systems.

FibreCAT SX systems support an open, heterogeneous environment. This means that FibreCAT SX systems are versatile and can be deployed flexibly in distributed, multi-vendor environments and in computer centers. Upgrading capacity is a simple operation that can be performed online.

The ServerView Operations Manager (referred to simply as the Operations Manager below) allows you to monitor FibreCAT SX storage subsystems (referred to simply as FibreCAT SX below) and to query detailed information on the individual FibreCAT SX systems.

This document describes

– the preparations required to monitor FibreCAT SX systems with the Operations Manager:

See Preparing for FibreCAT SX monitoring.

– how to use the Operations Manager to monitor FibreCAT SX systems and query detailed information on the FibreCAT SX systems:

See Monitoring FibreCAT SX systems with the ServerView Operations Manager.

FibreCAT SX 5

Page 6: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

... preparations Monitoring with the Operations Manager

1.1 Preparing for FibreCAT SX monitoring

To be able to monitor FibreCAT SX systems using the Operations Manager, a number of measures need to be implemented on the management server and on the individual FibreCAT SX systems.

This section provides information on the following topics:

– Software requirements on the management server and the FibreCAT SX system

– Installing the software on the management server and the FibreCAT SX system.

– Activities after installation

6 FibreCAT SX

Page 7: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

Monitoring with the Operations Manager ... preparations

1.1.1 Software requirements

The following software requirements apply for monitoring FibreCAT SX systems with the Operations Manager.

1.1.1.1 Software required on the management server (Windows)

– Microsoft Windows Server 2003 R2 SP2

The Windows SNMP services must be installed and configured.

– Sun Java Runtime Environment JRE

– ServerView S2 as of V4.50 or ServerView Operations Manager V4.70

– ServerView Storage Manager (StorMan) as of Version 1.3 or higher

1.1.1.2 Software required on the FibreCAT SX system

– Firmware: J110 or J200

– The SNMP service must have been set up for the storage processor.

You can set the SNMP parameters either at the Web interface or via CLI on the Management Controller:

Ê Under the Web interface, choose:

Manage – Event Notification – SNMP Configuration

or

Ê Enter the command set snmp-parameters at the CLI.

FibreCAT SX 7

Page 8: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

... preparations Monitoring with the Operations Manager

1.1.2 Installing the software

Proceed as follows:

1. Install the Sun Java Runtime Environment on your management server.

You will find the software on the PRIMERGY ServerView Suite Software CD or you can download it at:

http://support.ts.fujitsu.com/prim_supportcd/start.html

2. Install the ServerView Operations Manager on your management server.

You will find the software on the PRIMERGY ServerView Suite Software CD or you can download it at:

http://support.ts.fujitsu.com/prim_supportcd/start.html

3. Install ServerView Storage Manager (StorMan) on your management server.

You will find the software on the PRIMERGY ServerView Suite Software CD or you can download it at:

http://support.ts.fujitsu.com/prim_supportcd/start.html

4. Check the Release Notice to see what combinations of versions are supported for the ServerView Operations Manager and ServerView Storage Manager (StorMan).

5. Use the following commands to check the version and status of the Storage Manager (StorMan) installation on your management server:

C:\Program Files\Fujitsu\StorMan\bin>storinfo and C:\Program Files\Fujitsu\StorMan\bin>storcheck

I The SMI-S Provider is integrated in the storage processor (RAID controller) of the FibreCAT SX system. This means that you do not have to install the SMI-S Provider separately.

You can query the status of the SMI-S Provider using the graphical interface of the FibreCAT SX system.

8 FibreCAT SX

Page 9: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

Monitoring with the Operations Manager ... preparations

1.1.3 Activities after installation

After you have successfully installed the software, proceed as follows:

1. Refer to the README file for ServerView Storage Manager (StorMan) for information on any last-minute changes.

2. Ensure that the StorMan service has been started.

FibreCAT SX 9

Page 10: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

Server list Monitoring with the Operations Manager

1.2 Monitoring FibreCAT SX systems with the ServerView Operations Manager

With FibreCAT SX systems, the ServerView Storage Manager (StorMan) software provides the necessary information to the ServerView Operations Manager to allow the information to be displayed in ServerView. A special storage subsystem icon indicates FibreCAT SX systems in the server list.

1.2.1 Integrating FibreCAT SX in ServerView alarm management

In order to allow SNMP traps from the FibreCAT SX system to be passed to the Operations Manager, you must configure the Event Monitor.

I The SMI-S Provider integrated in FibreCAT SX is automatically regis-tered in the StorMan database by the ServerView Operations Manager as soon as the Operations Manager has detected the FibreCAT SX system.

I You can specify what events are forwarded by specifying the error severity/error category. It is even possible to select individual events.

10 FibreCAT SX

Page 11: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

Monitoring with the Operations Manager Server list

1.2.2 Showing FibreCAT SX systems in the Operations Manager server list

This completes all preparations for monitoring FibreCAT SX systems using the ServerView Operations Manager.

To add a FibreCAT SX system to the server list, add one of the two storage processors (RAID controllers) for this system to the server list:

1. Open the Server Browser window in the Operations Manager.

2. Add the storage processor (RAID controller) to the server list:

a) Enter the IP address of the storage processor (RAID controller) in the Server Address tab.

b) Click the Search button.

c) Leave the remaining default settings unchanged.

d) Confirm your entries by clicking Apply.

3. If you also wish to add the second storage processor (RAID controller) to the server list (this is not required):

a) Enter the IP address of the storage processor (RAID controller) in the Server Address tab.

b) Click the Search button.

c) Change the name of the storage processor.

d) Leave the remaining default settings unchanged.

e) Confirm your entries by clicking Apply.

I It is necessary to change the name of the second storage processor because all objects configured for the server list must have unique names.

FibreCAT SX 11

Page 12: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

Server list Monitoring with the Operations Manager

The FibreCAT SX system is then shown in the server list:

12 FibreCAT SX

Page 13: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

Monitoring with the Operations Manager Details

1.2.3 Showing detailed information on the FibreCAT SX system

You query information on a FibreCAT SX system by clicking the FibreCAT SX system you require in the ServerList window. This opens the SV - Storage window, where you can view Status Overview.

I Note that when FibreCAT SX systems are displayed in the ServerView Operations Manager, vendor-independent terminology is used.

FibreCAT SX terminology ServerView naming conventions

Storage Processor RAID Controller

Virtual Disk (vdisks) RAID Group

Volume LUN (Logical Unit Number)

FibreCAT SX 13

Page 14: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

Status Overview Monitoring with the Operations Manager

Status Overview

The Status Overview shows the status of the FibreCAT SX system along with the most important model-specific information.

14 FibreCAT SX

Page 15: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

Monitoring with the Operations Manager System Information

System Information

Choose Configuration - System Information to show detailed information on the FibreCAT SX system.

FibreCAT SX 15

Page 16: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

Port List Monitoring with the Operations Manager

Port List (RAID Controller)

Choose Raid Controller - <RAID Controller-Name> - Port List to list information on the ports of a RAID controller.

16 FibreCAT SX

Page 17: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

Monitoring with the Operations Manager Environmental

Environmental

Choose Enclosures - <physical hard disk> - Environmental to list information on the power supply units of the RAID controllers and the fans of a (physical) hard disk drive.

FibreCAT SX 17

Page 18: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

Disk Drive (Physical Disk) Monitoring with the Operations Manager

Disk Drive (Physical Disk)

Choose Enclosures - <physical hard disk> - Physical Disk to list information on a physical hard disk of a FibreCAT SX system.

18 FibreCAT SX

Page 19: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

Monitoring with the Operations Manager Virtual Disks

Virtual Disks (RAID Groups)

Choose Storage Pools - Overview to list information on a virtual hard disk drive (RAID group).

FibreCAT SX 19

Page 20: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

Storage Volumes Monitoring with the Operations Manager

Storage Volumes

Choose Storage Pools - Storage Volumes to list information on the storage volumes of the FibreCAT SX system.

20 FibreCAT SX

Page 21: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

Monitoring with the Operations Manager Host mapping

Host mapping

Storage Pools - Host mapping shows how the managed servers are assigned to the storage volumes.

FibreCAT SX 21

Page 22: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system
Page 23: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

Index

19

Aactivities after installation 9alarm management

ServerView 10

CCLARiiON LUNs 20

Ddetailed information (FibreCAT SX

system) 15Disk Drive (Physical Disk) 18

EEnvironmental 17

Ffans (FibreCAT SX system) 17FibreCAT SX monitoring

preparations 6software requirements 7

FibreCAT SX systemdetailed information 15Disk Drive (Physical Disk) 18Environmental 17Host mapping 21information on fans and power

supply 17information on LUN host

mapping 21information on physical hard

disk 18information on storage

volumes 20information on virtual disk 19integrating in alarm

management 10model-specific information 14

monitoring 10Port List 16port-specific information 16server list 11showing detailed information 13software requirements 7Status Overview 14Storage Volumes 20System Information 15

HHost mapping 21

Iinformation

on virtual disk (FibreCAT SX system) 19

information on host mapping (FibreCAT SX system) 21

information on physical hard diskFibreCAT SX system 18

information on storage volumesFibreCAT SX system 20

installsoftware 8

LLUN (Logical Unit Number) 13LUN host mapping

see host mapping

Mmanagement server

software requirements 7model-specific information

FibreCAT SX system 14monitor

FibreCAT SX system with Opera-tions Manager 10

monitoring (FibreCAT SX)preparations 6

FibreCAT SX 23

Page 24: Monitoring FibreCAT SX systems with ServerView Operations …manuals.ts.fujitsu.com/file/6702/fibrecat-sx-en.pdf · 2018-02-20 · FibreCAT SX system 16 power supply FibreCAT SX system

Index

PPort List 16port-specific information

FibreCAT SX system 16power supply

FibreCAT SX system 17preparations

FibreCAT SX monitoring 6

RRAID Controller 13, 16, 17

see also storage processorRAID Group 13RAID Groups 19

Sserver list

FibreCAT SX system 11ServerView alarm management 10ServerView Storage Manager

(StorMan) 10software installation 8software requirements

FibreCAT SX system 7management server 7

Status Overview 14Storage Manager see ServerView

Storage Manager (StorMan) 10Storage Processor 13storage processor

see also RAID controllerStorage Volumes 20StorMan 10System Information 15

VVirtual Disk 13virtual disk 19Volume 13

WWWN, see WWPNWWPN 21

24 FibreCAT SX