Tel: 248-295-0880 e-mail: [email protected] www.acromag.com
9 0 0 M B S e r i e sM
odbu
s I/O
BusW
orks
®
917/918MBMulti-ChannelAnalog OutputModules
DC Current or DC Voltage Outputs
Discrete Outputs
Models917MB: 4 current output channels918MB: 4 voltage output channels
Analog Output917MB: 0 to 20mA, 4 to 20mA, 0 to 1mA DC918MB: 0 to 10V, 0 to 5V, 0 to 1V DC
Discrete OutputFour output channels:Open-drain MOSFETs (1A DC loads)0 to 35V DC
Network CommunicationModbus-RTU high-speed RS-485
Power Requirement12 to 36V DC (917MB), 10 to 36V DC (918MB),24V AC
ApprovalsCE marked. UL, cUL listed Class I; Division 2; Groups A, B, C, D.
n DescriptionThese modules drive four analog output channelsand also feature four discrete outputs for on/offcontrol. Isolation separates the output, power,and network circuits. Network communicationadheres to the industry-standard RS-485 ModbusRTU protocol. AC and DC power sources aresupported with nonpolarized, diode-coupled terminals.
The analog outputs generate a signal based oncommunication from the host. They accommo-date wide DC voltage or current ranges.
Discrete outputs provide simple on/off switchingcapability (open-drain) for external devices.
Combining analog outputs, on/off controllers,and a network interface in a single package,makes this instrument extremely powerful. Multi-channel design adds cost-efficiency andallows high-density mounting. Plus, safe, ruggedconstruction make it reliable for both controlroom and distributed field I/O use in a broadrange of temperature control applications.Custom module configurations are also possible(consult factory for details).
n Special Featuresn Standard Modbus RTU protocol with high-speed
RS-485 communication (up to 115K bps)
n 12-bit D/A yields 0.1% of span resolution andaccuracy
n Four analog outputs in an inch-wide modulereduces system costs and saves panel space
n Four discrete outputs enable host-controlledon/off switching
n Heavy-duty 1A solid-state relays providedependable on/off control of industrial devices
n Self-calibration lowers maintenance costs byreducing periodic manual calibration checks
n Watchdog timers provide a configurablefailsafe output state for use when hostI/O communication is lost
n Three-way isolation eliminates potentialground loops between power, output, andnetwork circuitry
n Self-diagnostics monitor microcontroller activityto detect operational failures (lock-up) andexecute a reset to restore communication
Modbus
Four�Analog�Outputs�
�DC Current�
or�DC Voltage
RS-485
10-36V DC�or 24V AC
Isolation
Four�Discrete�Outputs
Power
Outputs (4)Outputs (2)
Outputs (2)
Analog Output ModuleModbus/RS-485
8400100.qxp 3/20/2006 3:17 PM Page 60
8401-003
Tel: 248-295-0880 e-mail: [email protected] www.acromag.com
M o d b u s I / OM
odbus I/OBusW
orks ®
n Performance
n General Analog OutputResolutionSee current/voltage output specifications for moreinformation.
Ambient Temperature EffectBetter than ±0.001% of output span per °C, or±1.0uV/°C, whichever is greater.
Ambient TemperatureOperation (917MB): -25°C to 60°C* (-13°F to 140°F*).Operation (918MB): -25°C to 70°C (-13°F to 158°F).Storage: -40°C to +85°C (-40°F to +185°F).* Limit 917MB maximum ambient to 50°C (122°F)when using supply voltages less than 15V DC.
n Current Output (917MB)DC Current Output RangesRange user-configured. Range selected applies to allchannels. Output Range Resolution Accuracy (% span)0 to 1mA 0.554% ±2.0% (±0.002mA)0 to 20mA 0.028% ±0.1% (±0.02mA)4 to 20mA 0.035% ±0.1% (±0.02mA)
Maximum Output Current22.5mA DC typical.
Integral Non-Linearity±0.1% of span or ±2 LSB typical, whichever is larger,for spans equal to or greater than 16mA.
Output Compliance12V minimum, 12.7V typical.
Output Load Resistance Range0 to 630 ohms typical.
Response Time11ms typical into 500 ohms, for measurement toreach 98% of the final value in response to a stepcommand. Actual response time will vary with load.
n Voltage Output (918MB)DC Voltage Output RangesRange user-configured. Selection applies to all channels.Output Range Resolution Accuracy (% span)0 to 1V 0.274% ±0.6% (±6mV)0 to 5V 0.055% ±0.1% (±5mV)0 to 10V 0.027% ±0.1% (±10mV)
Maximum Output Voltage11.255V DC typical.
Integral Non-Linearity±0.1% of span or ±2 LSB typical, whichever is larger,for spans equal to or greater than 5V.
Output Current0 to 10mA DC maximum.
Output Impedance1 ohm.
Output Short Circuit ProtectionIncluded.
Response Time110µs rise time typical, 150µs fall time typical,unloaded, for output to reach 98% of the final valuein response to a step command. Time varies with load.
n Discrete OutputOutput TypeFour independent open drain MOSFET switches with acommon return that operate as low-side switches.
Output Voltage Range0 to 35V DC (up to 1A/channel continuous).External voltage source required.
Output ON Resistance0.15 ohms maximum.
OperationDigital outputs are set to their OFF state following asoftware or power-on reset. Outputs may be set touser-defined states following a watchdog timeout.Watchdog timeout output control takes precedenceover limit alarm control. Alarm control takes prece-dence over host control.
Output Response Time4.1ms typical, from receipt of command to gate transition of the output MOSFET.
n CommunicationSupported Modbus CommandsThe command/response protocol for communicatingwith this module adheres to the Modbus/RTU standardfor the following Modbus Functions.
Read Coil (Output) Status Report Slave IDRead Holding Registers Reset SlaveRead Input RegistersForce Single Coil (Output)Preset Single Register Force Multiple Coils (Output)Preset Multiple Registers
LED IndicatorsLEDs indicate power, status, and discrete level/alarm.
n Power and IsolationPower Requirements10 to 36V DC (918MB), 12 to 36V DC (917MB)22 to 26V AC.
Supply CurrentSupply Current Draw (917) Current Draw (918)10V DC Not Recommended 100mA maximum12V DC 275mA maximum 85mA maximum24V DC 120mA maximum 45mA maximum24V AC 210mA rms max. 85mA rms max.
Isolation1500V AC for 60 seconds or 250V AC continuous. 3-way isolation between outputs, network, and powercircuits.
n OrderingInformation
Models917MB-0900918MB-0900DC current (917MB) or voltage (918MB) output module
Accessories900C-SIPConfiguration Software Interface Package(includes software CD-ROM for Windows, RS-232/485converter, and RS-485/three-wire cable)4001-095USB-to-RS232 adapterTBK-B02Optional terminal block kit, barrier strip style, 4 pcs.TBK-S02Optional terminal block kit, spring clamp style, 4 pcs.PS5R-VB24Power supply (24V DC, 2.1A)
DC CURRENT OUTPUT
ANALOG OUTPUT CONNECTIONS D
IGIT
AL
OU
TP
UT
S
45
46
TB4
OUT3
RTN
DIGITAL OUTPUT
TB
4
RTN
OUT2
OUT1
44
43
42
36
41
TB3
OUT0
D
COM
COM
D
RS
48
5
33
34
35
31
32
A
B
PW
R
TB
3
TB
1
ANALOG�OUTPUT
ANALOG�OUTPUT
TB
2
AC/DC�POWER
NETWORK�COMMUNICATION
DC VOLTAGE OUTPUT
TB1
I0+
RTN
12
11
AN
AL
OG
OU
TP
UT
S
13 RTN
I1+
RTN
14
15
AN
AL
OG
OU
TP
UT
S
16 RTN
TB2
21
22
I2+
RTN
I3+
RTN
23
24
RTN
26
25 RTN
TB1
V0+
RTN
12
11
AN
AL
OG
OU
TP
UT
S
13 RTN
V1+
RTN
14
15
AN
AL
OG
OU
TP
UT
S
16 RTN
TB2
21
22
V2+
RTN
V3+
RTN
23
24
RTN
26
25 RTN
TB1/TB2
+LR
I
TB1/TB2
+LR
WIRING CONNECTIONS SAME AS 913/914MB
10 TO 36V DC�OR 24V AC�NON-POLARIZED
I+
RTN
V+
RTN
8400100.qxp 3/20/2006 3:18 PM Page 61
8401-003
Tel: 248-295-0880 e-mail: [email protected] www.acromag.com
9 0 0 M B S e r i e sM
odbu
s I/O
BusW
orks
®
262524
TB2TB1
(110.5)4.35
(99.1)3.90
232221
TB
2
161512 13 1411
TB
1
D AB
PWR
TB3
33 313236 3435
TB4
414243444546
D
CO
MC
OM
RS485
TB
3
TB
4
DFT
32
10
ST
(118
.9)
4.68
(95.
3)3.
75
AcromagRUN
CL
(26.7)1.05
(59.
4)2.
34
NOTE: ALL DIMENSION ARE IN INCHES (MILLIMETERS)
"T" Rail Din Mounting Din EN 50022, 35mm
900MB Series Technical Diagrams
PERSONAL COMPUTERW/ WINDOWS 95/98 OR NT
RS-232 SERIALPORT CONNECTORAT BACK OF PC
RS-232 TO RS-485 CONVERTERMODEL 5034-214
900C-SIP COMMUNICATION CONNECTIONS
CONNECT THE RS-232SIDE OF CONVERTERTO THE PC
424345 44
TB
4
46
0 1
DFT
TB4
STSTATUS LED (YELLOW)RUN/PWR LED (GREEN)
DEFAULT MODE SWITCH -PUSH FOR DEFAULT MODE.
STATUS LED FLASHES INDEFAULT MODE.
RUNAcromag
INSTALL MODBUSCONFIGURATIONSOFTWARE
CAUTION: DO NOT CONNECT THECABLE DIRECTLY TO THE PC WITHOUTTHE CONVERTER, OR DAMAGE TOTHE MODULE MAY RESULT.
CABLE 5034-202
COM
D
D
CONNECT THE RS-485SIDE OF CONVERTERTO THE CABLE
CONNECT WIRES AS SHOWN
RS-485
GREENC
BLACK
RED
B
A
COLORWIRE
B AC
TB3
D
32
B
PWR
31
A
TB4
COM D
CO
M
CO
M
36 35
DD
34 33
RS485
41
TB
3
16 2221
TB
2
23 24 2625
TB2TB1
REFER TO THE USER'S MANUALTHAT CAME WITH YOUR MODULETO COMPLETE THE MODULE'SPOWER AND I/O CONNECTIONS
32
R
TB1
12 1311
ANY 900MB MODULE
TB
1
14 15
PC RUNNING�ACROMAG�
MODBUS CONFIG�SOFTWARE
8400100.qxp 3/20/2006 3:18 PM Page 68
8401-003
(This page intentionally left blank.)
Tel: 248-295-0880 e-mail: [email protected] www.acromag.com
M o d b u s I / OM
odbus I/OBusW
orks ®
■ Performance
■ Discrete Inputs(901 & 903 models only)Input Type12 active-low, buffered inputs, with a common con-nection. Inputs include transient suppression devicesand series connected 100K ohm resistors, plus diodeover-voltage clamps to the internal +5V supply.
Input Signal Voltage Range0 to 35V DC, maximum.
Input Current293µA, typical at 35V DC.
Input Signal ThresholdTTL compatible with 100mV of hysteresis, typical.Low-to-High threshold is 1.7VDC, High-to-Low is1.6VDC, typical. Limited to TTL levels of 0.8VDC(max. LOW level) and 2.0VDC (min. HIGH level).
Input Resistance100K ohms, typical.
Input Hysteresis100mV DC, typical.
■ Discrete Outputs(902 & 903 models only)Output Type12 independent, open-drain, DMOS MOSFET switcheswith a common source connection that operate aslow-side switches.
Output Voltage Range0 to 35V DC max. (0 to 500mA/channel continuous).External voltage source required.
Output ON Resistance0.28 ohms maximum.
Output Response TimeForce Single Coil: Output updates within 250µs ofreceipt of a command.Force Multiple Coils: First coil updates in 250µs, followed successively by additional coils every 180µs.
■ GeneralI/O Pull-ups and Socket5.6K ohm pull-up resistor SIPs are installed in socketsat each port (four-channels per port).
Excitation (per port)External excitation voltage for each four-channel portis limited to 35V or less.
Supported Modbus CommandsThe command/response protocol for communicatingwith this module adheres to the Modbus/RTU standardfor the following Modbus Functions.
Read Coil (Output) StatusRead Input Status Read Holding RegistersForce Single Coil (Output)Preset Single RegisterReset SlaveForce Multiple Coils (Outputs)Preset Multiple RegistersReport Slave ID
LED IndicatorsLEDs indicate power, status, and discrete level.
Power Requirements10 to 36V DC, 22 to 26V AC.
Supply CurrentSupply Current Draw10V DC 130mA maximum24V DC 54mA maximum24V AC 95mA maximum
Isolation1500V AC for 60 seconds or 250V AC continuous. 3-way isolation between I/O, network, and powercircuits.
■ OrderingInformation
Models901MB-0900Discrete input module902MB-0900Discrete output module903MB-0900Discrete input/output module
Accessories900C-SIPConfiguration Software Interface Package(includes software CD-ROM for Windows, RS-232/485 converter, and RS-485/three-wire cable)4001-095USB-to-RS232 adapterTBK-B02Optional terminal block kit, barrier strip style, 4 pcs.TBK-S02Optional terminal block kit, spring clamp style, 4 pcs.PS5R-VB24Power supply (24V DC, 2.1A)
DIGITAL INPUT CONNECTIONS (ACTIVE LOW) DIGITAL OUTPUT CONNECTIONS
RTN
+5V
INP
INP
RTN
CH 0
RTN
CH 1
CH 2
CH 3
5V TTL LOGIC - INPUT CAN BE PULLEDUP INTERNALLY OR EXTERNALLY
DIGITAL I/OSHARESRETURN
EXC1TB1
INTERNAL INPUTPULL-UPS ARE PRESENT
DIG
ITAL
INo
rO
UT
CH11
RTN
46
45
44CH10
RS
48
5
41
42
43
EXC3
TB4
CH 8
CH 9
35
36
COM
COM
TB1
DIG
ITAL
INo
rO
UT
12
11
CH 0
EXC1
CH 1
13
14
15
CH 2
CH 3
RTN
16
DIG
ITAL
INo
rO
UT
TB2
21 EXC2
CH 4
22
24
23
CH 6
CH 5
RTN
CH 7
25
26
34
33D
D
31
32
TB3
PW
R
DIGITALI/O
10 TO 36V DCOR 24V ACNON-POLARIZED
DIGITALI/O
DIGITALI/O AC/DC
POWER
NETWORKCOMMUNICATION
903MB shown.901MB & 902MB
are similar.
A
B
TB
3
TB
2
TB
4
TB
1
CH 0
RTN
CH 1
CH 2
CH 3
EXC1TB1
OUT
RTN
DIGITAL I/OSHARESRETURN
EXC
INP
SPSTRELAY
12-24V DC,TYPICAL
+
RTN
EXC
RTN
INP
5-35V
V
RTN
I/O
902MB/903MBON
TO OTHER 3CHAN OF PORT100K
OFF
EXC903MB
+5V
LOAD
Optional terminal blocks: barrier strip (left) and spring clamp (right). Cage clamp terminal is standard.
8401-003
Tel: 248-295-0880 ■ [email protected] ■ www.acromag.com ■ 30765 S Wixom Rd, Wixom, MI 48393 USA
PERSONAL COMPUTERRUNNING WINDOWS
98/ME/2000/XP
6 FEET OF CABLE
USB MALE
DB9P
RS232
4001095USB SERIAL CONVERTER
LED
TO HOST USB PORTHOSTUSB
CONFIGURATIONSOFTWARE
ACROMAGHOST PC RUNNING
Bulletin #8400-572B
DescriptionThis device is a USB-to-serial adapter that you can use to communicate with many Acromag I/O products for setup and re-configuration for your application.
Key Features & Benefits■ Connects to I/O modules via USB
(other adapters may be necessary)
■ Complete RS232 control signals
■ Conforms to USB Specification, Version 1.1
■ USB-powered
■ Cable length, 6 ft., UL approved
Performance SpecificationsUSB SpecificationVersion 1.1Data rateUp to 115.2KbpsEnvironmental StandardsRoHS-compliantBasic Power Consumption150mAPC RequirementsWindows® 7 and newer.
Ordering InformationNOTE: For more information visit www.acromag.com.
Adapters4001-095USB to serial adapter. Includes driver CD and manual.5030-913Serial port adapter. DB9S connector to RJ11 jack.5034-202RS-485 to 3-wire cable converter and cable, DB-9M to 3 x 12AWG RS-485 cable, 8 ft. 5032-787RS-232 to 151T transmitter configuration device converter and cable, 6 ft. 5034-214Non-isolated RS-232 to RS-485 Serial Port Converter, DB-9F to DB-9F.
Cables5030-902Cable. 6 feet long with RJ11 plug at each end.
Simplifies configuration of Acromag I/O Modules ◆ Enables configuration via USB port
Model 4001-095 USB-to-Serial Adapter
Accessories
All trademarks are property of their respective owners. Copyright © Acromag, Inc. 2019. Data subject to change without notice. Printed in USA 5/2019.
9-PIN CONNECTOR (DB9S)
RJ11 PLUG(6 CONDUCTOR)
(6 CONDUCTOR)RJ11 JACK
INTELLIPACK
MODEL 5030-913
SERIAL ADAPTER
MODEL 5030-902(6 feet long)
BC
D D
RS
-232
COM
A
RS
-485
5034-202
CABLE 5034-202
RS232 TO RS485 SERIALCONVERTER(MODEL 5034-214)
DB9 MALEDB9 FEMALE DB9 FEMALE
IntelliPack 800x Series Adapter and Cable