SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION MON-10467 10 kHz, Fmax Wireless Vibration Measurement Device Read this document before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Visit ni.com/manuals for more information about your product, including specifications, pinouts, and instructions for connecting, installing, and configuring your system. Note In this document, the MON-10467 (AC), MON-10467 (DC), and MON-10467 (BATTERY) are referred to inclusively as the MON-10467. The information in this document applies to all versions of the MON-10467 unless otherwise specified. Icons Notice—Take precautions to avoid data loss, loss of signal integrity, degradation of performance, or damage to the model. Caution—Take precautions to avoid injury. Consult the model documentation for cautionary statements when you see this icon printed on the model. Cautionary statements are localized into French for compliance with Canadian requirements. Shock Warning—Take precautions to avoid electrical shock. ESD Sensitive—Take precautions to avoid damaging the model with electrostatic discharge. Safety Caution Observe all instructions and cautions in the user documentation. Using the model in a manner not specified can damage the model and compromise the built-in safety protection. Return damaged models to NI for repair. Attention Suivez toutes les instructions et respectez toutes les mises en garde de la documentation utilisateur. L'utilisation d'un modèle de toute autre façon que celle spécifiée risque de l'endommager et de compromettre la protection de sécurité intégrée. Renvoyez les modèles endommagés à NI pour réparation. Caution The protection provided by the MON-10467 can be impaired if it is used in a manner not described in the user documentation. Attention La protection apportée par le MON-10467 risque d'être endommagée s'il est utilisé d'une autre façon que celle décrite dans la documentation utilisateur. Caution All wiring must be insulated for the highest voltage used. Attention Tout le câblage doit être isolé pour la plus haute tension utilisée. Caution An external circuit breaker box must be installed according to applicable electrical codes by trained personnel to serve as the power disconnect when installing the MON-10467 (AC). The circuit breaker box must be easy to reach and marked as the power disconnect for the device. Attention Un boîtier de disjoncteur externe doit être installé par du personnel qualifié, conformément aux normes électriques en vigueur, afin de servir de dispositif de coupure de courant lors de l'installation du MON-10467 (AC). Le boîtier du disjoncteur doit être facilement accessible et marqué en tant que dispositif de coupure de courant pour l'appareil. Caution Disconnect external power to the MON-10467 (AC) and use the external circuit breaker box to completely remove mains power before opening the device for service. Attention Débranchez l'alimentation externe du MON-10467 (AC) et utilisez le boîtier de disjoncteur externe pour couper complètement l'alimentation secteur avant d'ouvrir l'appareil pour l'entretien. Caution Remove power to the MON-10467 (DC) before opening it for service. Attention Mettez le MON-10467 (DC) hors tension avant de l'ouvrir pour l'entretien. Caution Conduit or gland fittings must be installed by trained personnel according to applicable electrical standards and the torque specified by the manufacturer.

MON-10467 Safety, Environmental, and Regulatory ...AC primary to DC secondary 264 V AC, reinforced, verified by a 3,000 V RMS withstand AC primary to chassis 264 V AC, basic, verified

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MON-10467 Safety, Environmental, and Regulatory ...AC primary to DC secondary 264 V AC, reinforced, verified by a 3,000 V RMS withstand AC primary to chassis 264 V AC, basic, verified

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION

MON-1046710 kHz, Fmax Wireless Vibration Measurement Device

Read this document before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiringinstructions in addition to requirements of all applicable codes, laws, and standards. Visit ni.com/manuals for more information about your product, includingspecifications, pinouts, and instructions for connecting, installing, and configuring your system.

Note In this document, the MON-10467 (AC), MON-10467 (DC), and MON-10467 (BATTERY) are referred to inclusively as the MON-10467. Theinformation in this document applies to all versions of the MON-10467 unless otherwise specified.

Icons

Notice—Take precautions to avoid data loss, loss of signal integrity, degradation of performance, or damage to the model.

Caution—Take precautions to avoid injury. Consult the model documentation for cautionary statements when you see this icon printed on themodel. Cautionary statements are localized into French for compliance with Canadian requirements.

Shock Warning—Take precautions to avoid electrical shock.

ESD Sensitive—Take precautions to avoid damaging the model with electrostatic discharge.

Safety

Caution Observe all instructions and cautions in the user documentation. Using the model in a manner not specified can damage the model andcompromise the built-in safety protection. Return damaged models to NI for repair.

Attention Suivez toutes les instructions et respectez toutes les mises en garde de la documentation utilisateur. L'utilisation d'un modèle de toute autrefaçon que celle spécifiée risque de l'endommager et de compromettre la protection de sécurité intégrée. Renvoyez les modèles endommagés à NI pourréparation.

Caution The protection provided by the MON-10467 can be impaired if it is used in a manner not described in the user documentation.

Attention La protection apportée par le MON-10467 risque d'être endommagée s'il est utilisé d'une autre façon que celle décrite dans ladocumentation utilisateur.

Caution All wiring must be insulated for the highest voltage used.

Attention Tout le câblage doit être isolé pour la plus haute tension utilisée.

Caution An external circuit breaker box must be installed according to applicable electrical codes by trained personnel to serve as the powerdisconnect when installing the MON-10467 (AC). The circuit breaker box must be easy to reach and marked as the power disconnect for the device.

Attention Un boîtier de disjoncteur externe doit être installé par du personnel qualifié, conformément aux normes électriques en vigueur, afin deservir de dispositif de coupure de courant lors de l'installation du MON-10467 (AC). Le boîtier du disjoncteur doit être facilement accessible et marquéen tant que dispositif de coupure de courant pour l'appareil.

Caution Disconnect external power to the MON-10467 (AC) and use the external circuit breaker box to completely remove mains power beforeopening the device for service.

Attention Débranchez l'alimentation externe du MON-10467 (AC) et utilisez le boîtier de disjoncteur externe pour couper complètementl'alimentation secteur avant d'ouvrir l'appareil pour l'entretien.

Caution Remove power to the MON-10467 (DC) before opening it for service.

Attention Mettez le MON-10467 (DC) hors tension avant de l'ouvrir pour l'entretien.

Caution Conduit or gland fittings must be installed by trained personnel according to applicable electrical standards and the torque specified by themanufacturer.

Page 2: MON-10467 Safety, Environmental, and Regulatory ...AC primary to DC secondary 264 V AC, reinforced, verified by a 3,000 V RMS withstand AC primary to chassis 264 V AC, basic, verified

Attention Les raccords de conduits ou presse-étoupe doivent être installés par du personnel qualifié conformément aux normes électriquesapplicables et au couple spécifié par le fabricant.

Caution Fire, explosion, and severe burn hazard. The MON-10467 (BATTERY) contains replaceable primary lithium batteries. Do not recharge ordisassemble the batteries. Do not heat the batteries or the MON-10467 (BATTERY) above 100 °C. Do not incinerate the batteries or theMON-10467 (BATTERY). Do not expose the contents of the batteries to water.

Attention Risque d'incendie, d'explosion et de brûlures graves. Le MON-10467 (BATTERY) contient piles au lithium primaire remplaçable. Ne pasrecharger ou démonter les piles. Ne pas chauffer les piles ou le MON-10467 (BATTERY) à une température supérieure à 100 °C. Ne pas incinérer lespiles ou le MON-10467 (BATTERY). Éviter tout contact du contenu des piles avec de l'eau.

Caution Risk of explosion if MON-10467 (BATTERY) batteries are replaced by an incorrect type. Dispose of used batteries according to theinstructions.

Attention Risque d'explosion si les piles est remplacée par un type de pile incorrect. Éliminer les piles usagées conformément aux instructions.

Caution The batteries of the MON-10467 (BATTERY) must be replaced by a trained service technician. Refer to the MON-10467 (BATTERY) UserGuide on ni.com/manuals for instructions for replacing the batteries.

Attention La pile doit être remplacée par un technicien de maintenance qualifié. Reportez-vous au Guide de l'utilisateur du MON-10467 (BATTERY)sous ni.com/manuals pour obtenir les instructions pour changer les piles.

Safety Voltages

MON-10467 (AC) Safety VoltagesConnect only voltages that are within the following limits.

Analog inputAI+ to AI- ±30 V DC, Measurement Category IAI+ to chassis ground ±35 V maximum, common-modeAI- to chassis ground ±35 V maximum, common-modeC to chassis ground ±35 V maximum, common-modeOvervoltage protection, AI+ to AI- ±35 V DC

Power inputAC input 100 V AC to 240 V AC, Overvoltage Category II

IsolationChannel-to-channel NoneChannel-to-chassis NoneAC primary to DC secondary 264 V AC, reinforced, verified by a 3,000 V RMS withstandAC primary to chassis 264 V AC, basic, verified by a 1,500 V RMS withstand

Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage.MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondarycircuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltagesources, and electronics.

Note Measurement Categories CAT I and CAT O are equivalent. These test and measurement circuits are for other circuits not intended for directconnection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV.

Caution Do not connect the analog inputs of the MON-10467 (AC) to signals or use for measurements within Measurement Categories II, III, or IV.

Attention Ne connectez pas les entrées analogiques du MON-10467 (AC) à des signaux et ne l'utilisez pas pour effectuer des mesures dans lescatégories de mesure II, III ou IV.

MON-10467 (DC) Safety VoltagesConnect only voltages that are within the following limits.

Analog inputAI+ to AI- ±30 V DC, Measurement Category IAI+ to chassis ground ±35 V maximum, common-modeAI- to chassis ground ±35 V maximum, common-modeC to chassis ground ±35 V maximum, common-modeOvervoltage protection, AI+ to AI- ±35 V DC

2 | ni.com | MON-10467 Safety, Environmental, and Regulatory Information

Page 3: MON-10467 Safety, Environmental, and Regulatory ...AC primary to DC secondary 264 V AC, reinforced, verified by a 3,000 V RMS withstand AC primary to chassis 264 V AC, basic, verified

IsolationChannel-to-channel NoneChannel-to-chassis None

Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage.MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondarycircuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltagesources, and electronics.

Note Measurement Categories CAT I and CAT O are equivalent. These test and measurement circuits are for other circuits not intended for directconnection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV.

Caution Do not connect the analog inputs of the MON-10467 (DC) to signals or use for measurements within Measurement Categories II, III, or IV.

Attention Ne connectez pas les entrées analogiques du MON-10467 (DC) à des signaux et ne l'utilisez pas pour effectuer des mesures dans lescatégories de mesure II, III ou IV.

MON-10467 (BATTERY) Safety VoltagesConnect only voltages that are within the following limits.

Analog inputAI+ to AI- ±30 V DC, Measurement Category IAI+ to chassis ground ±35 V maximum, common-modeAI- to chassis ground ±35 V maximum, common-modeOvervoltage protection, AI+ to AI- ±35 V DC

IsolationChannel-to-channel NoneChannel-to-chassis None

Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage.MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondarycircuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltagesources, and electronics.

Note Measurement Categories CAT I and CAT O are equivalent. These test and measurement circuits are for other circuits not intended for directconnection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV.

Caution Do not connect the analog inputs of the MON-10467 (BATTERY) to signals or use for measurements within Measurement Categories II, III,or IV.

Attention Ne connectez pas les entrées analogiques du MON-10467 (BATTERY) à des signaux et ne l'utilisez pas pour effectuer des mesures dansles catégories de mesure II, III ou IV.

MON-10467 (AC) Safety Guidelines for Hazardous VoltagesIf hazardous voltages are connected to the device, take the following precautions. A hazardous voltage is a voltage greater than 42.4 V peak voltage or60 V DC in DRY LOCATIONS, and 22.6 V peak or 35 V DC in WET LOCATIONS.

Caution Only the MON-10467 (AC) power input can be connected to hazardous voltages. Do not connect the MON-10467 (DC) orMON-10467 (BATTERY) to hazardous voltages.

Attention Seule l'entrée d'alimentation du MON-10467 (AC) peut être connectée à des tensions dangereuses. Ne connectez pas le MON-10467 (DC)ou le MON-10467 (BATTERY) à des tensions dangereuses.

Caution Ensure that hazardous voltage wiring is performed only by qualified personnel adhering to local electrical standards.

Attention S'assurer que le câblage à tension dangereuse est effectué par du personnel qualifié respectant les normes électriques locales.

Caution When device terminals are hazardous voltage LIVE, you must ensure that devices and circuits connected to the device are properly insulatedfrom human contact.

Attention Lorsqu'une haute tension dangereuse est appliquée aux bornes de l'appareil, s'assurer que les appareils et les circuits auxquels il estconnecté sont correctement isolés de tout contact humain.

Caution All wiring must be properly insulated for the environmental rating and highest voltage used.

Attention Tout câblage doit être correctement isolé pour le classement de l'environnement et la tension la plus élevée utilisée.

MON-10467 Safety, Environmental, and Regulatory Information | © National Instruments Corporation | 3

Page 4: MON-10467 Safety, Environmental, and Regulatory ...AC primary to DC secondary 264 V AC, reinforced, verified by a 3,000 V RMS withstand AC primary to chassis 264 V AC, basic, verified

Safety Compliance StandardsThis product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:• IEC 61010-1, EN 61010-1• UL 61010-1, CSA C22.2 No. 61010-1

Note For safety certifications, refer to the product label or the Product Certifications and Declarations section.

Electromagnetic and Radio Equipment Compatibility GuidelinesThis device was designed to support an efficient use of the radio spectrum to avoid harmful interference. This device was tested and complies with theregulatory requirements and limits for electromagnetic compatibility (EMC) as stated in the device specifications. These requirements and limits are designedto provide reasonable protection against harmful interference when the device is operated in its intended operational electromagnetic environment.

This device is intended for use in commercial and light-industrial locations. However, harmful interference may occur in some installations or when the deviceis connected to a peripheral device or a test object, or if the product is used in residential areas. To minimize interference with radio and television receptionand prevent unacceptable performance degradation, install and use this device in strict accordance with the instructions in the device documentation.

Furthermore, any changes or modifications to the device not expressly approved by NI could void your authority to operate it under your local regulatory rules.

Electromagnetic Compatibility NoticesRefer to the following notices for cables, accessories, and prevention measures necessary to ensure the specified EMC performance.

Notice For EMC declarations and certifications, and additional information, refer to the Product Certifications and Declarations section.

Notice The length of the signal cable must be no longer than 30 m (100 ft).

Notice Operate this product only with shielded cables and accessories.

Notice The performance of this product can be disrupted if subjected to Electrostatic Discharge (ESD) during operation. To prevent damage,industry-standard ESD prevention measures must be employed during installation, maintenance, and operation.

Radio Equipment Compatibility StandardsThis product meets the requirements of the following Radio Equipment standards:• FCC 47 CFR Part 15C: Intentional Radiators• RSS-247: DTSs, FHSs, and LE-LAN

This radio equipment is for use in accordance with the following parameters:

Antenna 2.4 GHz, 1.5 dBi, 50 Ω RP-SMA Antenna (part number 148977-01)Software InsightCM version 3.6.3 or laterFrequency band(s) 2.400 GHz to 2.4835 GHzRadio frequency power 20 dBm

Environmental GuidelinesNotice This device is intended for use in both indoor and outdoor applications. If your application is outdoors (non-weather-protected according toIEC 60721-3-4), or if the device might be directly exposed to an outdoor climate (partially weather-protected according to IEC 60721-3-3, 3K4 orgreater), you must use a desiccant pack from the desiccant kit (part number 787006-10) to meet the humidity specifications below. Refer to yourdevice's manual on ni.com/manuals for more information on using the accessory kit.

Notice Use the glands provided by NI or other strain reliefs rated for Type 3 or greater enclosures to strain relief all cables near the input connectors.Take care not to directionally bias cable connectors within input connectors when applying strain relief.

Notice NI recommends using a properly rated and approved sealing component or sealing agent on the MON-10467 (AC) power supply and terminalblock ground and AC line terminals when using the device in an environment with high humidity or rapid temperature transitions to prevent oxidationor corrosion on the ground terminals and insulation breakdown between terminals.

Notice Fill any unused openings with plugs rated for Type 3 or greater ingress protection.

Notice Storing the MON-10467 (BATTERY) at a temperature higher than 50 °C will reduce the life expectancy of the batteries.

Notice Follow the mounting instructions according to the device manual on ni.com/manuals.

4 | ni.com | MON-10467 Safety, Environmental, and Regulatory Information

Page 5: MON-10467 Safety, Environmental, and Regulatory ...AC primary to DC secondary 264 V AC, reinforced, verified by a 3,000 V RMS withstand AC primary to chassis 264 V AC, basic, verified

Environmental CharacteristicsTemperature

Operating -40 °C to 70 °CStorage -40 °C to 85 °C

HumidityOperating (with desiccant kit, part number 787006-10) Up to 100% relative humidity, condensing or noncondensing, when glands are

properly installedOperating (without desiccant kit, part number 787006-10) 10% RH to 90% RH, noncondensingStorage 5% RH to 95% RH, noncondensing

Ingress protection IP54 or Type 3Pollution Degree 4Maximum altitude 2,000 m

Shock and Vibration

Shock and VibrationOperating vibration

Random 5 g RMS, 10 Hz to 500 HzSinusoidal 5 g, 10 Hz to 500 Hz

Operating shock 30 g, 11 ms half sine; 50 g, 3 ms half sine; 18 shocks at 6 orientations

Environmental StandardsThis product meets the requirements of the following environmental standards for electrical equipment.• IEC 60068-2-1 Cold• IEC 60068-2-2 Dry heat• IEC 60068-2-30 Damp heat, cyclic (12 + 12h cycle)• IEC 60068-2-78 Damp heat, steady state• IEC 60068-2-64 Random operating vibration• IEC 60068-2-6 Sinusoidal operating vibration• IEC 60068-2-27 Operating shock• IEC 60068-2-14 Change of temperature

Environmental ManagementNI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardoussubstances from our products is beneficial to the environment and to NI customers.

For additional environmental information, refer to the Commitment to the Environment web page at ni.com/environment. This page contains the environmentalregulations and directives with which NI complies, as well as other environmental information not included in this document.

Waste Electrical and Electronic Equipment (WEEE)EU Customers At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For moreinformation about how to recycle NI products in your region, visit ni.com/environment/weee.

电子信息产品污染控制管理办法(中国 RoHS)

5 40e NI 符合中国电子信息产品中限制使用某些有害物质指令(RoHS)。关于 NI 中国 RoHS 合规性信息,请登录 ni.com/environment/rohs_china。(For information about China RoHS compliance, go to ni.com/environment/rohs_china.)

Field Wiring

MON-10467 (AC) Field Wiring GuidelinesAdhere to the following guidelines when wiring the MON-10467 (AC).• Only use copper wire when connecting to AC mains terminals.• Only use wiring that is properly rated for voltage and temperature as needed for your application.• Disconnect the external power to the device and use the external circuit breaker box to completely remove mains power before opening the device for

service.

MON-10467 Safety, Environmental, and Regulatory Information | © National Instruments Corporation | 5

Page 6: MON-10467 Safety, Environmental, and Regulatory ...AC primary to DC secondary 264 V AC, reinforced, verified by a 3,000 V RMS withstand AC primary to chassis 264 V AC, basic, verified

• Ensure that the power wiring is not connected to the energized or live facility power source before connecting the power input.• Ensure that the protective earth wire has more slack than the power wires so that the grounding terminal always disconnects last and is connected to the

green/yellow terminal.

Note Read the device manual on ni.com/manuals for complete wiring and connecting instructions.

MON-10467 (AC) Field Wiring Specifications

Power Wiring

Minimum cable voltage rating 240 V ACMinimum insulator temperature rating 90 °CGland PG16 (supplied by NI)Terminal connection type Spring cageConductor wire size 0.08 mm2 to 2.5 mm2 (28 AWG to 14 AWG)Stripping length 10 mm

Signal Wiring

Gland M16 (supplied by NI)Terminal connection type Spring cageConductor wire size 0.08 mm2 to 1.5 mm2 (28 AWG to 14 AWG)Stripping length 5 mm to 6 mm

Note Refer to Gland Specifications on page 7 for specifications for the glands.

MON-10467 (DC) Field Wiring GuidelinesAdhere to the following guidelines when wiring the MON-10467 (DC).• Only use wiring that is properly rated for voltage and temperature as needed for your application.• Remove power from the device before opening it for service.

Note Read the device manual on ni.com/manuals for complete wiring and connecting instructions.

MON-10467 (DC) Field Wiring Specifications

Power Wiring

Minimum cable voltage rating 30 V DCGland PG16 (supplied by NI)Terminal connection type Spring cageConductor wire size 0.08 mm2 to 1.5 mm2 (28 AWG to 14 AWG)Stripping length 5 mm to 6 mm

Signal Wiring

Gland M16 gland (supplied by NI)Terminal connection type Spring cageConductor wire size 0.08 mm2 to 1.5 mm2 (28 AWG to 14 AWG)Stripping length 5 mm to 6 mm

Note Refer to Gland Specifications on page 7 for specifications for the glands.

MON-10467 (BATTERY) Field Wiring GuidelinesOnly use wiring that is properly rated for voltage and temperature as needed for your application.

Note Read the device manual on ni.com/manuals for complete wiring and connecting instructions.

6 | ni.com | MON-10467 Safety, Environmental, and Regulatory Information

Page 7: MON-10467 Safety, Environmental, and Regulatory ...AC primary to DC secondary 264 V AC, reinforced, verified by a 3,000 V RMS withstand AC primary to chassis 264 V AC, basic, verified

MON-10467 (BATTERY) Field Wiring Specifications

Ground Wiring

Gland M16 (1-pack, supplied by NI)Terminal connection type M4 SEMS screw for ring lug

Signal Wiring

Gland M16 gland (12-pack, supplied by NI)Terminal connection type Spring cageConductor wire size 0.08 mm2 to 1.5 mm2 (28 AWG to 14 AWG)Stripping length 5 mm to 6 mm

Note Refer to Gland Specifications on page 7 for specifications for the glands.

Gland SpecificationsRefer to the table below to see which glands to use for your device.

Table 1. Glands for Each Device

Device Wiring Gland

MON-10467 (AC) Power wiring PG16 (part number 148877-01)

Signal wiring M16 12-pack (part number 148876-12)

MON-10467 (DC) Power wiring PG16 (part number 148877-01)

Signal wiring M16 12-pack (part number 148876-12)

MON-10467 (BATTERY) Ground wiring M16 1-pack (part number 148876-01)

Signal wiring M16 12-pack (part number 148876-12)

Note The specifications for the M16 gland 12-pack and 1-pack are the same.

PG16 glandCable diameter range 5 mm to 9 mmBacking nut torque 5 N · m (44.2 in. · lb)Strain relief dome torque 3.33 N · m (29.5 in. · lb)Impact protection at -40 °C to 70 °C IK08Joules rating at -40 °C to 70 °C 5

M16 glandGray grommet cable diameter range 2 mm to 6 mmBlack grommet cable diameter range 4 mm to 8 mmBody threading torque 3.16 N · m (28 in. · lb)Backing nut torque 2.5 N · m (22.1 in. · lb)Strain relief dome torque 2.5 N · m (22.1 in. · lb)Impact protection

At -40 °C IK071

At 70 °C IK08Joules rating

At -40 °C 2At 70 °C 5

1 The M16 gland is rated for an impact energy level of IK07 (2J) when tested with a direct vertical impact per IEC 61010-1, 3rd edition, Table 15 and Clause8.2. The gland should be guarded against impacts exceeding 2J and only accessed for occasional operations such as installation, adjustment, ormaintenance.

MON-10467 Safety, Environmental, and Regulatory Information | © National Instruments Corporation | 7

Page 8: MON-10467 Safety, Environmental, and Regulatory ...AC primary to DC secondary 264 V AC, reinforced, verified by a 3,000 V RMS withstand AC primary to chassis 264 V AC, basic, verified

Regulatory Information

United States

FCC Radiation Exposure StatementCaution The radiated output power of this product is below the FCC radio frequency exposure limits. Nevertheless, this product should be used insuch a manner that the potential for human contact during normal operation is minimized. This product has been evaluated for and shown compliantwith the FCC RF Exposure limits under mobile exposure conditions (antennas are greater than 20 cm from a person's body). This product has also beenevaluated for and shown compliant with the FCC RF exposure limits under portable exposure conditions (antennas are within 20 cm of a person's body)when installed in certain specific configurations. Details of the authorized configurations can be found at https://fjallfoss.fcc.gov/oetcf/eas/reports/GenericSearch.cfm by entering the FCC ID number on the product.

Attention La puissance de sortie rayonnée de ce produit est inférieure aux limites d'exposition aux fréquences radio de la FCC. Néanmoins, ceproduit doit être utilisé de manière à minimiser la possibilité de contact humain pendant son fonctionnement normal. Après évaluation, ce produits'avère conforme aux limites d'exposition RF de la FCC dans des conditions d'exposition aux appareils mobiles (antennes à plus de 20 cm du corpshumain). Après évaluation, ce produit s'avère également conforme aux limites d'exposition RF de la FCC dans des conditions d'exposition aux appareilsportables (antennes à moins de 20 cm du corps humain) lorsqu'il est installé dans certaines configurations spécifiques. Saisissez le numérod'identification FCC du produit sur https://fjallfoss.fcc.gov/oetcf/eas/reports/GenericSearch.cfm pour obtenir des détails sur les configurationsautorisées.

Canada

Radio Frequency (RF) Exposure InformationThe radiated output power of this product is below the Innovation, Science and Economic Development Canada (ISED) radio frequency exposure limits. Thisproduct has been evaluated for and shown compliant with the IC Radio Frequency (RF) Exposure limits. The product should be used in such a manner suchthat the potential for human contact during normal operation is minimized.

This product has been certified for use in Canada. Status of the listing in the Innovation, Science and Economic Development Canada's REL (Radio EquipmentList) can be found at the following web address: https://sms-sgs.ic.gc.ca/equipmentSearch/searchRadioEquipments

Additional Canadian information on RF exposure also can be found at the following web address: http://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf08792.html

Informations sur l'exposition à la fréquence radio (FR)La puissance de sortie rayonnée de ce produit est inférieure aux limites d'exposition aux fréquences radio d'Innovation, Sciences et Développementéconomique Canada (ISDE). Après évaluation, ce produit s'avère conforme aux limites d'exposition aux fréquences radio (RF) d'ISDE. Ce produit doit êtreutilisé de manière à minimiser la possibilité de contact humain pendant son fonctionnement normal.

Ce produit a été certifié pour une utilisation au Canada. Le statut du référencement dans la Nomenclature du matériel radio (NMR) d'Innovation, Sciences etDéveloppement économique Canada se trouve à l'adresse Web suivante : https://sms-sgs.ic.gc.ca/equipmentSearch/searchRadioEquipments

Pour des informations canadiennes supplémentaires sur l'exposition FR, rendez-vous sur : http://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf08792.html

Taiwan R.O.C.台灣 : 國家通訊傳播委員會

低功率電波輻性電機管理辦法第十二條經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。第十四條低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。前項合法通信,指依電信規定作業之無線電信。低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。

Power Requirements

MON-10467 (AC) Power RequirementsAC input

Input rating 100 V AC to 240 V AC50/60 Hz10 W

Operating voltage range 85 V AC to 264 V ACNominal input frequency 50/60 Hz

8 | ni.com | MON-10467 Safety, Environmental, and Regulatory Information

Page 9: MON-10467 Safety, Environmental, and Regulatory ...AC primary to DC secondary 264 V AC, reinforced, verified by a 3,000 V RMS withstand AC primary to chassis 264 V AC, basic, verified

Operating frequency range 47 Hz to 63 HzMain power disconnect2 None

MON-10467 (DC) Power RequirementsDC input

Input rating 24 V DCInput power 6 W maximumOperating voltage range 19 V DC to 30 V DC

Caution Power to the MON-10467 (DC) must be supplied by a suitably rated SELV source with proper overload and short circuit protection.

Attention Le MON-10467 (DC) doit être alimenté par une source très basse tension de sécurité, de niveau approprié, avec une protection adéquatecontre les surcharges et les courts-circuits.

MON-10467 (BATTERY) Power RequirementsCaution Fire, explosion, and severe burn hazard. The MON-10467 (BATTERY) contains replaceable primary lithium batteries. Do not recharge ordisassemble the batteries. Do not heat the batteries or the MON-10467 (BATTERY) above 100 °C. Do not incinerate the batteries or theMON-10467 (BATTERY). Do not expose the contents of the batteries to water.

Attention Risque d'incendie, d'explosion et de brûlures graves. Le MON-10467 (BATTERY) contient piles au lithium primaire remplaçable. Ne pasrecharger ou démonter les piles. Ne pas chauffer les piles ou le MON-10467 (BATTERY) à une température supérieure à 100 °C. Ne pas incinérer lespiles ou le MON-10467 (BATTERY). Éviter tout contact du contenu des piles avec de l'eau.

Caution Risk of explosion if MON-10467 (BATTERY) batteries are replaced by an incorrect type. Dispose of used batteries according to theinstructions.

Attention Risque d'explosion si les piles est remplacée par un type de pile incorrect. Éliminer les piles usagées conformément aux instructions.

Caution The batteries of the MON-10467 (BATTERY) must be replaced by a trained service technician. Refer to the MON-10467 (BATTERY) UserGuide on ni.com/manuals for instructions for replacing the batteries.

Attention La pile doit être remplacée par un technicien de maintenance qualifié. Reportez-vous au Guide de l'utilisateur du MON-10467 (BATTERY)sous ni.com/manuals pour obtenir les instructions pour changer les piles.

The MON-10467 (BATTERY) is powered by a set of primary lithium batteries.

Replacement battery manufacturer TadiranReplacement battery model TL-5930/SNumber of batteries 3Cell chemistry Lithium Thionyl Chloride (Li-SOCl2)

Physical CharacteristicsDimensions (W × H × D)

Without antenna 294.97 mm × 312.94 mm × 111 mm(11.61 in. × 12.32 in. × 4.37 in.)

With antenna 294.97 mm ×408.61 mm × 111 mm(11.61 in. × 16.09 in. × 4.37 in.)

WeightMON-10467 (AC) 4.74 kg (10.45 lb)MON-10467 (DC) 4.36 kg (9.61 lb)MON-10467 (BATTERY) (with batteries installed) 4.90 kg (10.80 lb)

MaintenanceCaution Disconnect external power to the MON-10467 (AC) and use the external circuit breaker box to completely remove mains power beforeopening the device for service.

Attention Débranchez l'alimentation externe du MON-10467 (AC) et utilisez le boîtier de disjoncteur externe pour couper complètementl'alimentation secteur avant d'ouvrir l'appareil pour l'entretien.

2 You must install an external circuit breaker box to serve as the power disconnect from AC mains.

MON-10467 Safety, Environmental, and Regulatory Information | © National Instruments Corporation | 9

Page 10: MON-10467 Safety, Environmental, and Regulatory ...AC primary to DC secondary 264 V AC, reinforced, verified by a 3,000 V RMS withstand AC primary to chassis 264 V AC, basic, verified

Caution Remove power to the MON-10467 (DC) before opening it for service.

Attention Mettez le MON-10467 (DC) hors tension avant de l'ouvrir pour l'entretien.

When opening the device for service, inspect the seal for damage and remove any debris before closing. When closing the device, apply 1.3 N · m(11.5 in. · lb) torque to the door fasteners.

Export ComplianceThis product is subject to control under the U.S. Export Administration Regulations (15 CFR Part 730 et. seq.) administered by the U.S. Department ofCommerce's Bureau of Industry and Security (BIS) (www.bis.doc.gov) and other applicable U.S. export control laws and sanctions regulations. This productmay also be subject to additional license requirements of other countries' regulations.

Additionally, this product may also require export licensing before being returned to NI. The issuance of a Return Material Authorization (RMA) by NI doesnot constitute export authorization. The user must comply with all applicable export laws prior to exporting or re-exporting this product. See ni.com/legal/export-compliance for more information and to request relevant import classification codes (e.g. HTS), export classification codes (e.g. ECCN), and otherimport/export data.

MON-10467 (BATTERY) Battery RecyclingThe MON-10467 (BATTERY) contains replaceable lithium batteries. Products containing lithium must be disposed of or recycled in accordance with all locallaws and site regulations.

Refer to the MON-10467 User Guide on ni.com/manuals for how to remove and replace used batteries. For more information about disposing of or recyclingused batteries, please refer to the battery manufacturer's website at tadiran.com.

You can also recycle used batteries through NI's global take-back program. Through the NI global take-back program, NI covers all costs of returning itshardware products and ensures that the products are properly recycled. This service helps reduce the impact on landfills and other disposal sites and providesan environmentally safe end-of-life solution. Hardware products can be sent to NI for recycling by emailing [email protected].

Return ProcessIf you need to return your device to NI, follow the return material authorization (RMA) process. For more information on the RMA process, [email protected] or call (866) 275-6964 for returns for repair or (877) 493-2406 for returns to stock.

Caution If you need to return the MON-10467 (BATTERY), you must remove the batteries and sign a letter confirming that they have been removedbefore shipping the device to NI.

Attention Si vous devez renvoyer le MON-10467 (BATTERY), vous devez retirer les piles et signer un courrier confirmant qu'elle a été retirée avantd'expédier l'appareil à NI.

Removing the Batteries from the MON-10467 (BATTERY) Before ShippingTools and supplies needed:• 1/4 in. socket or 1/4 in. (6 mm) flat-blade screwdriver• #1 Phillips screwdriver

Complete the following steps to remove the batteries from the MON-10467 (BATTERY) before shipping it to NI. Do not ship the batteries. Refer to theMON-10467 (BATTERY) Battery Recycling section for how to recycle used batteries.1. Loosen the four captive screws on the door of the device with a 1/4 in. socket or 1/4 in. (6 mm) flat-blade screwdriver.2. Open the door of the device slowly.3. Unscrew the captive screws on the bracket with a #1 Phillips screwdriver and remove it.4. Remove used batteries by pulling them straight out or using a non-conductive tool.

Product Certifications and DeclarationsRefer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NIproducts, visit ni.com/product-certifications, search by model number, and click the appropriate link.

Additional ResourcesVisit ni.com/manuals for more information about your product, including specifications, pinouts, and instructions for connecting, installing, and configuringyour system.

NI ServicesVisit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such astutorials and examples.

Visit ni.com/services to learn about NI service offerings such as calibration options, repair, and replacement.

10 | ni.com | MON-10467 Safety, Environmental, and Regulatory Information

Page 11: MON-10467 Safety, Environmental, and Regulatory ...AC primary to DC secondary 264 V AC, reinforced, verified by a 3,000 V RMS withstand AC primary to chassis 264 V AC, basic, verified

Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updatesfrom NI.

NI corporate headquarters is located at 11500 N Mopac Expwy, Austin, TX, 78759-3504, USA.

MON-10467 Safety, Environmental, and Regulatory Information | © National Instruments Corporation | 11

Page 12: MON-10467 Safety, Environmental, and Regulatory ...AC primary to DC secondary 264 V AC, reinforced, verified by a 3,000 V RMS withstand AC primary to chassis 264 V AC, basic, verified

Information is subject to change without notice. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other productand company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriatelocation: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find informationabout end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NOEXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S.Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as setforth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.