Hotwire ThermostatInstructions
Model Number: HWTH1
HotwireThermostatInstructions
Turning your heating Off Manually:
Your thermostat and floor are both off and your floor will cool down. Any
settings you have entered into the Thermostat will be maintained
Australia
Verve Distribution6 Todd StPort Adelaide SA 5015
www.vervedistribution.com.au
New Zealand
The Heating CompanyPO BOX 420 Whitianga NZ
www.hotwire.co.nz
Program button
Confirm button
Set the clock
Set the day of the week
7
8
6
5
4
3
2
1
RT stands for “room temperature” and FT stands for “floor temperature”.
Power button, to turn on/off the thermostat9
Manu
Auto
Indicates the time frames available in Auto Mode.
Heating is turned on
“Manu” indicates manual mode, “Auto” indicates automatic mode. In
Auto mode, the thermostat executes the preprogrammed schedules.
While in Manu mode, the thermostat maintains a constant set temperature
manually set by the user.
Button and Descriptions
RT/FT
1 2 3 4
Press clock button, and time display will start flashing
Use the up and down buttons to adjust .Holding the
Press the OK button once the time is set.
Press the day button to get to the current Day of the week.
Step One: Set The Time and Day:
Turning your heating on and off Automatically
buttons down will increase or decrease the time in 15 minutes increments.
Ensure that the thermostat is on Auto mode.
Step Two: Set the thermostat to Auto mode
Turning your heating On Manually:
Press the up or down button to adjust to the required temperature
Around 23degC is an average but you can increase if required.
Press OK button to exit.
Step Three: Programming your schedulesIf you set your thermostat to 7 day programmable mode
If you set your thermostat to 5+2 day programmable mode
(1). Press Prog button.
(3). Press up or down buttons to adjust the time you wish the program 1 event to commence for the currently selected day. and then press Prog button.
(2). Press up or down buttons to select the day you wish to start programming. then press Prog.(hold up button to select all days of the week, to cancel, hold up button again.)
(4). Press up or down buttons to set the temperature for this time period,then press Prog.
(6). Press OK to save and exit.
(8). Press OK to save and exit.
(5). Set time and temperature for the next time period. Repeat step(2) and (3) for each time period.
(1). Press Prog button.(2). Press up or down buttons to adjust the time you wish the program 1 event to commence for the week days( from Monday to Friday). and then press Prog button.
(5). Press up or down buttons to adjust the time you wish the program 1 event to commence for the weekends( Saturday and Sunday). and then press Prog button.
(3). Press up or down buttons to set the temperature for this time period,then press Prog.(4). Set time and temperature for the next time period. Repeat step(2) and (3) for each time period. and then press Prog button.
(6). Press up or down buttons to set the temperature for this time period,then press Prog.(7). Set time and temperature for the next time period. Repeat step(5) and (6) for each time period.
icon will display.
Key Lock & Unlock
Press and hold to unlock the thermostat. The lock icon will disappear.
* Note no program changes are possible while the unit is locked.
Press and hold to lock the thermostat. A lock
In Auto mode, to temporary override the current setpoint temperature,1. Press up or down button once, the set temperature starts flashing.2. Press up or down button again to adjust the set temperature.3. Press OK button to confirm the setting with OVERRIDE shown.
Now your thermostat will maintain the new set temperature until the next setpoint. To cancel the override setting, press Del button once.
Temporary temperature override
In standby mode(when thermostat is turned off), press and hold Clock button and
Your thermostat has the ability to reset all settings to the factory defaults. If you are certain you want to do this:
Day button for 5 seconds until --:-- is shown(shown for 5 seconds only)
Resetting factory defaults
MOMO
To select Auto use the mode button
Press the power button to turn on your thermostat.
Press the ok button. The reading will return to the ambient temperature
Press Power button to turn off your thermostat, you will see OFF on LCD.
Press the Mode button until the screen shows manual.
Australia
Verve Distribution81 Brighton Rd
Glenelg SA 5045
www.vervedistribution.com.au
New Zealand
The Heating CompanyInternationalPO Box 420
Whitianga NZ
www.hotwire.co.nz
HotwireThermostatInstructions
Turning your heating Off Manually:
Your thermostat and floor are both off and your floor will cool down. Any
settings you have entered into the Thermostat will be maintained
Australia
Verve Distribution6 Todd StPort Adelaide SA 5015
www.vervedistribution.com.au
New Zealand
The Heating CompanyPO BOX 420 Whitianga NZ
www.hotwire.co.nz
Program button
Confirm button
Set the clock
Set the day of the week
7
8
6
5
4
3
2
1
RT stands for “room temperature” and FT stands for “floor temperature”.
Power button, to turn on/off the thermostat9
Manu
Auto
Indicates the time frames available in Auto Mode.
Heating is turned on
“Manu” indicates manual mode, “Auto” indicates automatic mode. In
Auto mode, the thermostat executes the preprogrammed schedules.
While in Manu mode, the thermostat maintains a constant set temperature
manually set by the user.
Button and Descriptions
RT/FT
1 2 3 4
Press clock button, and time display will start flashing
Use the up and down buttons to adjust .Holding the
Press the OK button once the time is set.
Press the day button to get to the current Day of the week.
Step One: Set The Time and Day:
Turning your heating on and off Automatically
buttons down will increase or decrease the time in 15 minutes increments.
Ensure that the thermostat is on Auto mode.
Step Two: Set the thermostat to Auto mode
Turning your heating On Manually:
Press the up or down button to adjust to the required temperature
Around 23degC is an average but you can increase if required.
Press OK button to exit.
Step Three: Programming your schedulesIf you set your thermostat to 7 day programmable mode
If you set your thermostat to 5+2 day programmable mode
(1). Press Prog button.
(3). Press up or down buttons to adjust the time you wish the program 1 event to commence for the currently selected day. and then press Prog button.
(2). Press up or down buttons to select the day you wish to start programming. then press Prog.(hold up button to select all days of the week, to cancel, hold up button again.)
(4). Press up or down buttons to set the temperature for this time period,then press Prog.
(6). Press OK to save and exit.
(8). Press OK to save and exit.
(5). Set time and temperature for the next time period. Repeat step(2) and (3) for each time period.
(1). Press Prog button.(2). Press up or down buttons to adjust the time you wish the program 1 event to commence for the week days( from Monday to Friday). and then press Prog button.
(5). Press up or down buttons to adjust the time you wish the program 1 event to commence for the weekends( Saturday and Sunday). and then press Prog button.
(3). Press up or down buttons to set the temperature for this time period,then press Prog.(4). Set time and temperature for the next time period. Repeat step(2) and (3) for each time period. and then press Prog button.
(6). Press up or down buttons to set the temperature for this time period,then press Prog.(7). Set time and temperature for the next time period. Repeat step(5) and (6) for each time period.
icon will display.
Key Lock & Unlock
Press and hold to unlock the thermostat. The lock icon will disappear.
* Note no program changes are possible while the unit is locked.
Press and hold to lock the thermostat. A lock
In Auto mode, to temporary override the current setpoint temperature,1. Press up or down button once, the set temperature starts flashing.2. Press up or down button again to adjust the set temperature.3. Press OK button to confirm the setting with OVERRIDE shown.
Now your thermostat will maintain the new set temperature until the next setpoint. To cancel the override setting, press Del button once.
Temporary temperature override
In standby mode(when thermostat is turned off), press and hold Clock button and
Your thermostat has the ability to reset all settings to the factory defaults. If you are certain you want to do this:
Day button for 5 seconds until --:-- is shown(shown for 5 seconds only)
Resetting factory defaults
MOMO
To select Auto use the mode button
Press the power button to turn on your thermostat.
Press the ok button. The reading will return to the ambient temperature
Press Power button to turn off your thermostat, you will see OFF on LCD.
Press the Mode button until the screen shows manual.
HotwireThermostatInstructions
Turning your heating Off Manually:
Your thermostat and floor are both off and your floor will cool down. Any
settings you have entered into the Thermostat will be maintained
Australia
Verve Distribution6 Todd StPort Adelaide SA 5015
www.vervedistribution.com.au
New Zealand
The Heating CompanyPO BOX 420 Whitianga NZ
www.hotwire.co.nz
Program button
Confirm button
Set the clock
Set the day of the week
7
8
6
5
4
3
2
1
RT stands for “room temperature” and FT stands for “floor temperature”.
Power button, to turn on/off the thermostat9
Manu
Auto
Indicates the time frames available in Auto Mode.
Heating is turned on
“Manu” indicates manual mode, “Auto” indicates automatic mode. In
Auto mode, the thermostat executes the preprogrammed schedules.
While in Manu mode, the thermostat maintains a constant set temperature
manually set by the user.
Button and Descriptions
RT/FT
1 2 3 4
Press clock button, and time display will start flashing
Use the up and down buttons to adjust .Holding the
Press the OK button once the time is set.
Press the day button to get to the current Day of the week.
Step One: Set The Time and Day:
Turning your heating on and off Automatically
buttons down will increase or decrease the time in 15 minutes increments.
Ensure that the thermostat is on Auto mode.
Step Two: Set the thermostat to Auto mode
Turning your heating On Manually:
Press the up or down button to adjust to the required temperature
Around 23degC is an average but you can increase if required.
Press OK button to exit.
Step Three: Programming your schedulesIf you set your thermostat to 7 day programmable mode
If you set your thermostat to 5+2 day programmable mode
(1). Press Prog button.
(3). Press up or down buttons to adjust the time you wish the program 1 event to commence for the currently selected day. and then press Prog button.
(2). Press up or down buttons to select the day you wish to start programming. then press Prog.(hold up button to select all days of the week, to cancel, hold up button again.)
(4). Press up or down buttons to set the temperature for this time period,then press Prog.
(6). Press OK to save and exit.
(8). Press OK to save and exit.
(5). Set time and temperature for the next time period. Repeat step(2) and (3) for each time period.
(1). Press Prog button.(2). Press up or down buttons to adjust the time you wish the program 1 event to commence for the week days( from Monday to Friday). and then press Prog button.
(5). Press up or down buttons to adjust the time you wish the program 1 event to commence for the weekends( Saturday and Sunday). and then press Prog button.
(3). Press up or down buttons to set the temperature for this time period,then press Prog.(4). Set time and temperature for the next time period. Repeat step(2) and (3) for each time period. and then press Prog button.
(6). Press up or down buttons to set the temperature for this time period,then press Prog.(7). Set time and temperature for the next time period. Repeat step(5) and (6) for each time period.
icon will display.
Key Lock & Unlock
Press and hold to unlock the thermostat. The lock icon will disappear.
* Note no program changes are possible while the unit is locked.
Press and hold to lock the thermostat. A lock
In Auto mode, to temporary override the current setpoint temperature,1. Press up or down button once, the set temperature starts flashing.2. Press up or down button again to adjust the set temperature.3. Press OK button to confirm the setting with OVERRIDE shown.
Now your thermostat will maintain the new set temperature until the next setpoint. To cancel the override setting, press Del button once.
Temporary temperature override
In standby mode(when thermostat is turned off), press and hold Clock button and
Your thermostat has the ability to reset all settings to the factory defaults. If you are certain you want to do this:
Day button for 5 seconds until --:-- is shown(shown for 5 seconds only)
Resetting factory defaults
MOMO
To select Auto use the mode button
Press the power button to turn on your thermostat.
Press the ok button. The reading will return to the ambient temperature
Press Power button to turn off your thermostat, you will see OFF on LCD.
Press the Mode button until the screen shows manual.
Delete mistakes during programming.
Up button. Also a long press (5 seconds ) will lock the keypad.
Down button. Also a long press (5 seconds ) will un lock the keypad.
Flame icon should now be shown on screen
Button and DescriptionsProgram button
Delete mistakes during programming.
Select the Automatic or Manual operating mode.
Confirm button
To set the clock. Press the clock button press the up and down buttons
Press to select day of the week. Press repeatedly to select different
days
Up button. Also a long press (5 seconds ) will lock the keypad.
Down button. Also a long press (5 seconds ) will un lock the keypad.
Power button, to turn on/off the thermostat
RT stands for “room temperature” and FT stands for “floor temperature”.
Heating is turned on
“Manu” indicates manual mode, “Auto” indicates automatic mode. In
Auto mode, thermostat executes the preprogrammed schedules.
While in Manu mode, the thermostat maintains a constant set temperature
manually set by the user.
Indicates the time frames available in Auto Mode.
Prog
Del
Mode
Ok
Clock
Day
+
-
RT/FT
Manu
Auto
and then press Ok.
1 2 3 4
Turning your heating on and off Automatically
Step One: Set The Time and Day:(1). Press the clock button and the time display will start flashing, use the up and
down buttons to adjust.
(2). Holding the buttons down will increase or decrease the time in 15 minutes
increments. Press the OK button once the time is set.
(3). Press the day button to get to the current Day of the week.
(4). Press OK button to exit.
Ensure that the thermostat is on Auto mode. To select Auto mode press the Mode
Step Two: Set the thermostat to Auto mode
button until Auto is displayed.Your thermostat has 4 events each day. An Event is
the moment at which the Thermostat will switch the heating on or off. For example
Event 1 is the moment at which your heating will be activated each morning. Event
2 is when it will switch off in the morning. Event 3 is the evening or afternoon
activation, Event 4 is the time in evening or afternoon at which the heating will
switch off.
Step Three: Programming your schedulesTo set your thermostat to 5+2 day programmable mode (Your thermostat will do
the same thing Monday to Friday and can be programmed for different times on
the weekend)
(1). Press Prog button.
(2). Press up or down buttons to adjust the time you wish the Event 1 to com-
mence for the week days( from Monday to Friday). and then press Prog button.
(3). Press up or down buttons to set the temperature for this Event, then press
Prog.
(4). Set time and temperature for the next event. Repeat step(2) and (3) for each
time period. and then press Prog button.
(5). Press up or down buttons to adjust the time you wish Event to commence for
the weekends( Saturday and Sunday). and then press Prog button.
(6). Press up or down buttons to set the temperature for this event, then press
Prog.
(7). Set time and temperature for the next event. Repeat step(5) and (6) for each
event.(8). Press OK to save and exit.
HotwireThermostatInstructionsMenu Settings
Press Power buttton to turn off the thermostat. Press and hold button Prog for 3 seconds to bring up a configuration menu. Now press Prog button to select different menu number.
Set the temperature readout(AF model only). This gives option to choose to show air A= to show air temperature,
A - F = to show both in 5 second intervals temperature,floor temperature or to show both floor & air in interval.
01 = 5+2 day programmable02 = 7 day programmable
LOAD (16A)
FEED230 VAC
Floor Sensor
LL NN Power Supply:
220Vac +10%, 50/60Hz
Load Capability: <16 A, 220VAC
Accuracy: 1deg C
Set-point range: ambient 5~30 deg C
floor 5~40 deg C
Storage: -20~50 deg C
Sensor selection. This thermostat is a combination model allowing you to choosebetween 3 different models. (A, AF,F,)A model: air only , with built in sensor
AF model: air & floor , with both built in and remote sensorF model: floor onl y , with remote sensor
Menu #
1
Switching differential.
Calibrate the room temperature. This feature is used to compensate for any difference
Calibrate the floor temperature. This feature is used to compensate for any difference
Set the floor temperature limit(AF model only).
Select temperature format
Select 12 / 24 hour clock 24 12 / 24
2
3
4
5
6
7
8
9
10
Feature Description Factory DefaultFeature Value
0°C
ON / OFF OFF
01
40
A
°C 20°C ~ 40 °C
°C / °F °C
A / AF / F A
Press up or down button to select
The numbers of degree difference before switching. The default is
between the displayed room temperature and a thermometer.
between the displayed floor temperature and a thermometer.
This feature is to protect the floor surface.
°C or °F.
Program type selection. This gives user 2 options of program type.(5+2 or 7 day programmable) 5+2 day will give you 5 days(Monday to Fiday) with the same four events(Wakeup, out,
7 day will give you individual settings for each day from Monday to Sunday.
home,sleep) and 2 days(Saturday and Sunday) with the same four events.
Frost protection. This feature is to avoid room temperature goes below 5 °C
1°C which means the thermostat will switch the heating on 0.5°C below the set temperature and will turn it off 0.5°C above the set temperature. With a 2°C differential, the heating will switch on 1°C below the set temperature and will switch off 1°C above the set temperature.
1°C 1°C ~ 5°C
-5°C ~ +5°C
0°C -5°C ~ +5°C
F=to show floor temperature,
To set your thermostat to 7 day programmable mode use the following steps
(1). Press Prog button.
(2). Press up or down buttons to select the day you wish to start programming.
Or hold up button to select all seven days of the week. Then press Prog. (to
cancel all seven days programming hold up button down) Time will start
flashing.
(3). Press up or down buttons to adjust the time you wish Event 1 to commence
for the currently selected day. and then press Prog button, Temperature will
start flashing.
(4). Press up or down buttons to set the temperature for this time period,then press
Prog.
(5). Set time and temperature for the next event. Repeat step(2) and (3) for each
event.
(6). Press OK to save and exit.
(Your thermostat will do the same thing for all seven days of the week)
HotwireThermostatInstructionsMenu Settings
Press Power buttton to turn off the thermostat. Press and hold button Prog for 3 seconds to bring up a configuration menu. Now press Prog button to select different menu number.
Set the temperature readout(AF model only). This gives option to choose to show air A= to show air temperature,
A - F = to show both in 5 second intervals temperature,floor temperature or to show both floor & air in interval.
01 = 5+2 day programmable02 = 7 day programmable
LOAD (16A)
FEED230 VAC
Floor Sensor
LL NN Power Supply:
220Vac +10%, 50/60Hz
Load Capability: <16 A, 220VAC
Accuracy: 1deg C
Set-point range: ambient 5~30 deg C
floor 5~40 deg C
Storage: -20~50 deg C
Sensor selection. This thermostat is a combination model allowing you to choosebetween 3 different models. (A, AF,F,)A model: air only , with built in sensor
AF model: air & floor , with both built in and remote sensorF model: floor onl y , with remote sensor
Menu #
1
Switching differential.
Calibrate the room temperature. This feature is used to compensate for any difference
Calibrate the floor temperature. This feature is used to compensate for any difference
Set the floor temperature limit(AF model only).
Select temperature format
Select 12 / 24 hour clock 24 12 / 24
2
3
4
5
6
7
8
9
10
Feature Description Factory DefaultFeature Value
0°C
ON / OFF OFF
01
40
A
°C 20°C ~ 40 °C
°C / °F °C
A / AF / F A
Press up or down button to select
The numbers of degree difference before switching. The default is
between the displayed room temperature and a thermometer.
between the displayed floor temperature and a thermometer.
This feature is to protect the floor surface.
°C or °F.
Program type selection. This gives user 2 options of program type.(5+2 or 7 day programmable) 5+2 day will give you 5 days(Monday to Fiday) with the same four events(Wakeup, out,
7 day will give you individual settings for each day from Monday to Sunday.
home,sleep) and 2 days(Saturday and Sunday) with the same four events.
Frost protection. This feature is to avoid room temperature goes below 5 °C
1°C which means the thermostat will switch the heating on 0.5°C below the set temperature and will turn it off 0.5°C above the set temperature. With a 2°C differential, the heating will switch on 1°C below the set temperature and will switch off 1°C above the set temperature.
1°C 1°C ~ 5°C
-5°C ~ +5°C
0°C -5°C ~ +5°C
F=to show floor temperature,
HotwireThermostatInstructionsMenu Settings
Press Power buttton to turn off the thermostat. Press and hold button Prog for 3 seconds to bring up a configuration menu. Now press Prog button to select different menu number.
Set the temperature readout(AF model only). This gives option to choose to show air A= to show air temperature,
A - F = to show both in 5 second intervals temperature,floor temperature or to show both floor & air in interval.
01 = 5+2 day programmable02 = 7 day programmable
LOAD (16A)
FEED230 VAC
Floor Sensor
LL NN Power Supply:
220Vac +10%, 50/60Hz
Load Capability: <16 A, 220VAC
Accuracy: 1deg C
Set-point range: ambient 5~30 deg C
floor 5~40 deg C
Storage: -20~50 deg C
Sensor selection. This thermostat is a combination model allowing you to choosebetween 3 different models. (A, AF,F,)A model: air only , with built in sensor
AF model: air & floor , with both built in and remote sensorF model: floor onl y , with remote sensor
Menu #
1
Switching differential.
Calibrate the room temperature. This feature is used to compensate for any difference
Calibrate the floor temperature. This feature is used to compensate for any difference
Set the floor temperature limit(AF model only).
Select temperature format
Select 12 / 24 hour clock 24 12 / 24
2
3
4
5
6
7
8
9
10
Feature Description Factory DefaultFeature Value
0°C
ON / OFF OFF
01
40
A
°C 20°C ~ 40 °C
°C / °F °C
A / AF / F A
Press up or down button to select
The numbers of degree difference before switching. The default is
between the displayed room temperature and a thermometer.
between the displayed floor temperature and a thermometer.
This feature is to protect the floor surface.
°C or °F.
Program type selection. This gives user 2 options of program type.(5+2 or 7 day programmable) 5+2 day will give you 5 days(Monday to Fiday) with the same four events(Wakeup, out,
7 day will give you individual settings for each day from Monday to Sunday.
home,sleep) and 2 days(Saturday and Sunday) with the same four events.
Frost protection. This feature is to avoid room temperature goes below 5 °C
1°C which means the thermostat will switch the heating on 0.5°C below the set temperature and will turn it off 0.5°C above the set temperature. With a 2°C differential, the heating will switch on 1°C below the set temperature and will switch off 1°C above the set temperature.
1°C 1°C ~ 5°C
-5°C ~ +5°C
0°C -5°C ~ +5°C
F=to show floor temperature,
In Auto mode, to temporarily override the current setpoint temperature,
1. Press up or down button once, the set temperature starts flashing.
2. Press up or down button again to adjust the set temperature.
3. Press OK button to confirm the setting with OVERRIDE shown.
Now your thermostat will maintain the new set temperature until the next setpoint.
To cancel the override setting, press Del button once.
Temporary temperature override
Press and hold up button to lock the thermostat. A lock icon will display.
Key Lock & Unlock
Press and hold down button to unlock the thermostat. The unlock icon will dissapear.
Your thermostat has the ability to reset all settings to the factory defaults. In standby
mode(when thermostat is turned off), press and hold Clock button and
Day button for 5 seconds until --:-- is shown(shown for 5 seconds only)
* Note no program changes are possible while the unit is locked.
Resetting factory defaults
Defaults are as follows:
Event 1 7:00 am
Event 2 9:30 am
Event 3 4:30 pm
Event 4 10:30 pm
Installation Instructions
Using a screwdriver unscrew the front plate from the back plate. Then pull
the bottom of the thermostat towards you off the back plate. Wire up the
thermostat as per the wiring diagram below, then place the back plate into the flush
box and tighten it with the screws provided. To replace the thermostat put the top
into the backing plate and then push the bottom of the thermostat in. Then replace
screw holding both parts together.
Blue
wire
from
ele
men
t
Brow
n w
ire fr
om e
lem
ent
Line
from
sw
itch
box
230/240 VAC
Connect green wire from theelement to the house earth
(Cables can go either side)
Hous
e Ne
utra
l
Menu # Feature ExplanationFactory default
Adjustment(Press up & down buttons to adjust)
01 Mode/Sensor Selection
This thermostat is a combination model whichallows you to choose 3 different modes
A mode = Air Sensing Only (Has built in sensor)AF mode = Air & Floor sensing
F mode = Floor sensing ( floor probe installed)
A A / AF / F
02 Switching differential
The number of degrees difference before switchingThe default is 1Deg C which means the stat will
switch the heating on 0.5DegC below the set temperature and will turn it off 0.5DegC above the
set temperature.With a 2 DegC differential the heating will switch
on 1 DegC below the set temperature and will switch off 1 DegC above the set temperature.
1 DegC 1 Deg C - 5 Deg C
03 Air Temp Calibration This is to recalibrate the air temp if required 0DegC -5 Deg C - + 5 Deg C
04 Floor Temp Calibration This is the recalibrate the floor temperature if req 0DegC - 5 Deg C - + 5 Deg C
05Temp Readout (AF mode only)
This gives you the option to show the Air Temp,floor Temp or to show both Air & Floor at intervals
A
A = Show Air TemperatureF = Show Floor Temperature
A-F = Show Floor and Air Temperature in 5 sec intervals
06Maximum Floor Temp
( AF Mode only)This is to protect the floor surface 40 DegC 20 Deg C - 40 Deg C
07Temperature For-
matThis allows the temperature to be set to show
Deg Celsius or Deg FahrenheitC Deg C / Deg F
08 Clock FormatYou can select the clock to show in either 12
or 24 hour time24 12 / 24
09 Frost Protection This is to avoid your room temp going below 5 DegC Off On / Off
10 5+2 or 7 Day mode This allows you to program either 5 days at once,
then the 2 days of the weekend separately, or a full 7 days at the same time.
01 01 = 5 + 2 Day Programming02 = 7 Day Programming
Hotwire ThermostatTechnical Information
To access Menu settings,
1. Press Power button to turn off the thermostat.
2. Press and hold button Prog for three seconds to bring up the configuration menu. Now press Prog button to select each different menu number.
Menu Settings
Page 2
Press , starts flashing, press or to adjust the setpoint among a range of 5~30 deg C. (for floor mode, the
range will be 5~40 deg C). Press to confirm.
Press and hold to lock the buttons. A lock icon will display.
Vacation mode is used to drop the heating down to a minimum set temperature to ensure room stays damp free.
Press and hold to unlock the buttons. The unlock icon will display.
220Vac 10%, 50/60HzDC 3 V (2 x 1.5 V AAA Alkaline batteries)
Accuracy: ±1
Set-point range: ambient 5~30 deg C floor 5~40 deg C
Storage: -20~50 deg C
Load Capability: <16 A, 220VAC
deg C
Wiring Diagram & Technical Specifications
Additional Functions
+230V AC
heating element
Floor Sensor
Probe N L M
This product should be installed by a qualified electrician.
Press this tab lightly back and simultaneously push the front panel upward to release it off the back plate. Wire up the Thermostat as per the wiring diagram below, then place theback into the flushbox, and tighten it with the screws provided.To replace the Thermostat, slide the front panel downwardonto the back plate.
Vacation Mode Adjustment
Key Lock & Unlock
Dimensions & Installation
Power Supply:
96 26.7
88.260
6
102240
58
119
122.
4
113.
685 10
10
95
51
110