57
Molecular Spectroscopy Visible and Ultraviolet Spectroscopy UV/VIS Spectroscopy UV/VIS Spectrometer Application for Quantitative An alysis

Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Embed Size (px)

Citation preview

Page 1: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Molecular SpectroscopyVisible and Ultraviolet Spectroscopy

- UV/VIS Spectroscopy- UV/VIS Spectrometer- Application for Quantitative Analysis

Page 2: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Ultraviolet: 190~400nm Violet:   400 - 420 nm Indigo:   420 - 440 nm Blue:   440 - 490 nm Green:   490 - 570 nm Yellow:   570 - 585 nm Orange:   585 - 620 nm Red:   620 - 780 nm

Page 3: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis
Page 4: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Internal Energy of Molecules

Etotal=Etrans+Eelec+Evib+Erot+Enucl

Eelec: electronic transitions (UV, X-ray)

Evib: vibrational transitions (Infrared)

Erot: rotational transitions (Microwave)

Enucl: nucleus spin (nuclear magnetic

resonance) or (MRI: magnetic resonance

imaging)

Page 5: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis
Page 6: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Electronic Spectroscopy

Ultraviolet (UV) and visible (VIS) spectroscopy This is the earliest method of molecular

spectroscopy. A phenomenon of interaction of molecules with

ultraviolet and visible lights. Absorption of photon results in electronic

transition of a molecule, and electrons are promoted from ground state to higher electronic states.

Page 7: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

UV and Visible Spectroscopy

In structure determination : UV-VIS spectroscopy is used to detect the presence of chromophores like dienes, aromatics, polyenes, and conjugated ketones, etc.

Page 8: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Electronic transitions

There are three types of electronic transition

which can be considered; Transitions involving , , and n

electrons Transitions involving charge-transfer

electrons Transitions involving d and f electrons

Page 9: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Absorbing species containing , , and n electrons

Absorption of ultraviolet and visible radiation in organic molecules is restricted to certain functional groups (chromophores) that contain valence electrons of low excitation energy.

Page 10: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

UV/VIS

Vacuum UV or Far UV (λ<190 nm )

Page 11: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis
Page 12: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Transitions

An electron in a bonding s orbital is excited to the corresponding antibonding orbital. The energy required is large. For example, methane (which has only C-H bonds, and can only undergo transitions) shows an absorbance maximum at 125 nm. Absorption maxima due to transitions are not seen in typical UV-VIS spectra (200 - 700 nm)

Page 13: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

n Transitions

Saturated compounds containing atoms with lone pairs (non-bonding electrons) are capable of n transitions. These transitions usually need less energy than transitions. They can be initiated by light whose wavelength is in the range 150 - 250 nm. The number of organic functional groups with n peaks in the UV region is small.

Page 14: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

n and Transitions

Most absorption spectroscopy of organic compounds is based on transitions of n or electrons to the excited state.

These transitions fall in an experimentally convenient region of the spectrum (200 - 700 nm). These transitions need an unsaturated group in the molecule to provide the electrons.

Page 15: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Chromophore Excitation max, nm Solvent

C=C →* 171 hexane

C=On→*→*

290180

hexanehexane

N=On→*→*

275200

ethanolethanol

C-X   X=Br, I

n→*n→*

205255

hexanehexane

Page 16: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis
Page 17: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Terms describing UV absorptions

1. Chromophores: functional groups that give

electronic transitions.

2. Bathochromic shift: shift to longer λ, also called red shift.

3. Hysochromic shift: shift to shorter λ, also called blue shift.

4. Hyperchromism: increase in ε of a band.

5. Hypochromism: decrease in ε of a band.

Page 18: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis
Page 19: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Selection RuleOrbital Spin States & Multiplicity

Singlet state (S):Most molecules have ground state with all electron spin paired and most excited state also have electron spin all paired, even though they may be one electron each lying in two different orbital. Such states have zero total spin and spin multiplicities of 1, are called singlet (S) states.

Total Spin Multiplicities

Page 20: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Multiplicity Triplet State

For some of the excited states, there are states with a pair of electrons having their spins parallel (in two orbitals), leading to total spin of 1 and multiplicities of 3.

Total Spin Multiplicities

Page 21: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Selection Rule

For triplet state: Under the influence of external field, there are three values (i.e. 3 energy states) of +1, 0, -1 times the angular momentum. Such states are called triplet states (T).

According to the selection rule, S→S, T→T, are allowed transitions, but S→T, T→S, are forbidden transitions.

Page 22: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Selection Rules of electronic transition

Electronic transitions may be classed as intense or weak according to the magnitude of εmax th

at corresponds to allowed or forbidden transition as governed by the following selection rules of electronic transition:

Spin selection rule: there should be no change in spin orientation or no spin inversion during these transitions. Thus, S→S, T→T, are allowed, but S→T, T→S, are forbidden. ( S=0 △ transition allowed)

Page 23: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis
Page 24: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Page 25: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Instrumentation

光源 分光器 樣品 偵測器 記錄器

Page 26: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Components of a SpectrophotometerLight Source

Deuterium Lamps- a truly continuous spectrum in the ultraviolet region is produced by electrical excitation of deuterium at low pressure. (160nm~375nm)

Tungsten Filament Lamps- the most common source of visible and near infrared radiation.

Page 27: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Components of a Spectrophotometer

Monochromator (分光器 /單光器 )

Used as a filter: the monochromator will select a narrow portion of the spectrum (the bandpass) of a given source

Used in analysis: the monochromator will sequentially select for the detector to record the different components (spectrum) of any source or sample emitting light.

Page 28: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

MonochromatorCzerny-Turner design

Page 29: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Grating

Page 30: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Photomultiplier Detector

Page 31: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Principle of Photomultiplier Detector

The type is commonly used. The detector consists of a photoemissive catho

de coupled with a series of electron-multiplying dynode stages, and usually called a photomultiplier.

The primary electrons ejected from the photo-cathode are accelerated by an electric field so as to strike a small area on the first dynode.

Page 32: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Principle of Photomultiplier Detector

The impinging electrons strike with enough energy to eject two to five secondary electrons, which are accelerated to the second dynode to eject still more electrons.

A photomultiplier may have 9 to 16 stages, and overall gain of 106~109 electrons per incident photon.

Page 33: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Single and Double Beam Spectrometer

Single-Beam: There is only one light beam or optical path from the source through to the detector.

Double-Beam: The light from the source, after passing through the monochromator, is split into two separate beams-one for the sample and the other for the reference.

Page 34: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis
Page 35: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Quantitative AnalysisBeer’s Law

A=bc

: the molar absorptivity (L mol-1 cm-1)

b: the path length of the sample

c :the concentration of the compound in solution, expressed in mol L-1

Page 36: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Transmittance

I0 I

b

303.2

log)log(

)log(303.2)ln(

0

00

00

00

0

k

bcATI

I

I

Ikbc

I

I

dbkcI

dI

kcdbI

dI

I

IT

I

I

b

Page 37: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis
Page 38: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

External Standard and the Calibration Curve

Page 39: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Fluorescence Spectroscopy

Page 40: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis
Page 41: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Excitation of Molecules

Excitation of molecules can be brought about by absorption of two bands of radiation, one centered about the wavelength 1(S0→S1) and the second around the shorter wavelength 2(S0→S2).

Page 42: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Vibrational Relaxation (VR)

The molecule can rapidly dissipate excess vibrational energy as heat by collision with solvent molecules.

Average lifetime of vibrational relaxation excited molecule is 10-12sec or less.

Fluorescence always involves a transition from the lowest vibrational level of an excited state to any one of the vibrational level of the ground state.

Page 43: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Internal Conversion (IC)

A molecule passes to a lower energy electronic state.

The molecule can pass from a low vibrational level of S2 to an equally energetic vibrational level of the first excited singlet S1.

The mechanism of internal conversion process S2→ S1 is not well understood.

Average lifetime of internal conversion process is 10-12sec or less.

Page 44: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Fluorescence

This process of emitting a photon for deexcitation of S1 to S0.

Average lifetime of fluorescence is 10-9~10-7sec.

Page 45: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Intersystem Crossing (ISC)

This process of non-radiative transfer from the singlet to the triplet state.

Intersystem crossing are most common in molecules that contain heavy atoms, such as iodine or bromine.

Interaction between the spin and orbital motions becomes large in the presence of such atoms.

Page 46: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Phosphorescence

From T1, the molecule can return to S0 by emission of photon.

A triplet-singlet transition is much less probability than a singlet-singlet conversion.

The excited triplet state with respect to emission ranges from 10-4 to 10sec.

Page 47: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Rate of Deactivation Processes

Absorption- 10-14~10-15sec Vibrational Relaxation and Internal Conversion - 10-12sec or less

Fluorescence- 10-9~10-7sec Phosphorescence- 10-3~10sec

Page 48: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Transition Types in Fluorescence

Fluorescence process seldom results from absorption of UV radiation of wavelengths lower than 250nm because such radiation is sufficiently energetic to cause deactivation of the excited states by pre-dissociation or dissociation

200nm radiation corresponds to about 140Kcal/mol; most molecules have at least some bonds that cane be ruptured.

Page 49: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Quantum Efficiency Comparisonfor →* and n→* transition The majority radiation of fluorescent compoun

ds is produced by a transition involving either the n→* or the →* excited state.

The molar absorptivity of a →* transition is ordinarily 100 to 1000 times greater than for an n→* process.

Page 50: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

The inherent lifetime associated with a →* transition is shorter (10-7 to 10-9 sec compared with 10-5 to 10-7 sec for an n→* process) and kf is larger. The rate constant for intersystem crossing ki is smaller for →* excited states.

Fluorescence is more commonly associated with →* states than with n→* states because the deactivation processes that compete with fluorescence are less likely to occur.

Page 51: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Fluorescence and Structure

The most intense and most useful fluorescent behavior is found in compounds containing aromatic functional groups with low energy →* transition levels.

Compounds containing aliphatic and alicyclic carbonyl structures or highly conjugated double bond structure may also exhibit fluorescence.

Page 52: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

H3C CH3

CH3

CH2OH

CH3 CH3 CH3

Organic Compounds for Fluorescence

Vitamin A has a blue fluorescence with an emission maximum at approximately 500nm in ethanol.

highly conjugated compound

Page 53: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis
Page 54: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis
Page 55: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Fluorescence Instrumentation

Source- xenon-arc lamp for higher wavelengths and mercury-arc lamp for shorter wavelengths

Lensing system- quartz lenses can be used in the ultraviolet wavelength range (200-380nm), and glass lenses can be used in the visible wavelength range (380nm-700nm)

Page 56: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis
Page 57: Molecular Spectroscopy Visible and Ultraviolet Spectroscopy - UV/VIS Spectroscopy - UV/VIS Spectrometer - Application for Quantitative Analysis

Fluorescence Instrumentation

Emission wavelength selector: this system is generally placed at an angle of 90o with respect to the excitation axis to minimize interferences from transmitted and scattered exciting light.

Beam Splitter: A beam splitter is a mirror of partial reflectance. A proportion of light would be reflected from the beam splitter while the rest would be transmitted through it unaffected.