Upload
jacqueline-davidson
View
224
Download
5
Tags:
Embed Size (px)
Citation preview
Moeller GmbHSeite - 1
SUCONET-K-Master SUCONET-K Master for XC100, 200
XIOC-NET-SK-M
D
ateiname
Schutzverm
erk ISO
16016 beachten
Moeller GmbHSeite - 2
XIOC-SER Suconet-K MasterProduct- Feature (1)
XC100, XC200 up to 2 modules can be used with XC100
up to 4 modules can be used in XC200
InterfaceRS485 interface
Removable cage clamp connector
Bus termination on board
Data exchange Up to 16 Suconet K /K1 remote stations
250/250 Byte for Send-/Receive data
Baud rate 187,5 / 375KB
D
ateiname
Schutzverm
erk ISO
16016 beachten
Moeller GmbHSeite - 3
TA/RA
TB/RB
Bus termination
XIOC-NET-SK-MProduct- Feature (2)
Diagnostic:
POW Power indicationERR ErrorDTR COMport open and Modul parameterizedDCD All Slaves okTxD Send data activityRxD Receive Data activity
D
ateiname
Schutzverm
erk ISO
16016 beachten
Moeller GmbHSeite - 4
XIOC-NET-SK-MSystem- Feature
All Suconet-K1/K slaves can be used PS3
PS4
EM4
PS4,S416
XIOC-SER
Other Suconet devices
EM4
XC100, XC200 XIOC-NET-SK-M
PS4
D
ateiname
Schutzverm
erk ISO
16016 beachten
Moeller GmbHSeite - 5
XIOC-NET-SK-MConfiguration XSOFT (1)
Select XIOC-NET-SK-M module Enter COM-Port Reference (1-5)
D
ateiname
Schutzverm
erk ISO
16016 beachten
Moeller GmbHSeite - 6
1. Activity of Suconet-K fieldbus is done via function block SuconetK_Master
Remote station data
Buffer for Send- and Receive data
XIOC-NET-SK-MConfiguration XSOFT (2)
D
ateiname
Schutzverm
erk ISO
16016 beachten
Moeller GmbHSeite - 7
2. Definition of remote stations
3. Declaration of buffers for Send- and Receive data
XIOC-NET-SK-MConfiguration XSOFT (3)
D
ateiname
Schutzverm
erk ISO
16016 beachten
Moeller GmbHSeite - 8
4. Access to send and receive data of a single remote station
Slave-Address
Send data (Outputs)Receive data (inputs)
Diagnostic
XIOC-NET-SK-MData access in XSOFT
D
ateiname
Schutzverm
erk ISO
16016 beachten
Moeller GmbHSeite - 9
Replacement of PS416, PS4-341
New functionality: Ethernet Gateway, OPC Server, WEB-Server, Data logging
Ethernet
XIOC-NET-SK-MApplication example
D
ateiname
Schutzverm
erk ISO
16016 beachten
Moeller GmbHSeite - 10
XIOC-NET-SK-MTechnical Data
Article number: 289982
List price: 550€
Typ XIOC-NET-SK-MNumber of modulesXC100 2XC200 4
max. Current 275 mAgalvanic isolation RS485 yesconnector 6 pin cage clampBaudrate 187,5 / 375KBnumber of slaves 16telegram Suconet K/ K1Send data max. 250Receive data max. 250
D
ateiname
Schutzverm
erk ISO
16016 beachten
Moeller GmbHSeite - 11
XC100: Version >= 04, Firmware >= V3.10
XC200 Version >=04, Firmware >= 1.03.02
XSoft V2.3.3 or
V2.3.2 + xc_update_03_05
Documentation:
•XIOC-Signal modules AWB 2725-1452
•Function blocks to XSOFT AWB 2786-1456
XIOC-NET-SK-MPrecondition