Modular Coil Metrology Data for Current Center Shift Calculation

Embed Size (px)

Citation preview

Modular Coil Metrology Data for Current Center Shift Calculation Romer Arm Measurements are taken at each turn. Bundle dimensions are averages of all turns: 4 turns for Base and Top 11 turns for Septum and Sides (A & B Coils, 10 for Cs) Lateral (dx) is calculated as the average of the four sets of measurements: A Sides A Septum B Sides B Septum Radial (dy) is calculated as the average of the four sets of measurements: A Base A Top B Base B Top Caution: All Romer Arm Data except A Sides is positive with respect to local x,y. Side A has surface normal in x direction so measurements must be negated before averaging. Side A Side B Current Center A Base B Base B Septum A Septum A Top A Sides B Top B Sides x y A Clamp Numbering B Clamp Numbering C Clamp Numbering