KM44 Engine type S4S-DT Alternator type AT00500T Performance class G2 50 400/230 APM303 GENERAL CHARACTERISTICS Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel DEC4000 POWER ESP PRP Voltage kWe kVA kWe kVA Standby Amps 200/115 35 44 32 40 127 240 TRI 35 44 32 40 106 230 TRI 35 44 32 40 110 220 TRI 35 44 32 40 115 220/127 28 35 25 32 92 415/240 35 44 32 40 61 400/230 35 44 32 40 64 380/220 35 44 32 40 67 DIMENSIONS COMPACT VERSION Length (mm) 1700 Width (mm) 896 Height (mm) 1223 Dry weight (kg) 680 Tank capacity (L) 100 DIMENSIONS SOUNDPROOFED VERSION Commercial reference of the enclosure M127 2080 960 1415 920 100 74 Length (mm) Width (mm) Height (mm) Dry weight (kg) Tank capacity (L) Acoustic pressure level @1m in dB(A) Sound power level guaranteed (Lwa) Acoustic pressure level @7m in dB(A) 91 POWER DEFINITION PRP : Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO 8528-1. ESP : The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO 8528-1. Overload is not allowed TERMS OF USE According to the standard, the nominal power assigned by the genset is given for 25°C Air Intlet Temperature, of a barometric pressure of 100 kPA (100 m A.S.L), and 30 % relative humidity. For particular conditions in your installation, refer to the derating table. ASSOCIATED UNCERTAINTY For the generator sets used indoor, where the acoustic pressure levels depend on the installation conditions, it is not possible to specify the ambient noise level in the operating and maintenance instructions. You will also find in our operating and maintenance instructions a warning concerning the air noise dangers and the need to implement appropriate preventive measures. This document is not contractual - Kohler Co. reserves the right to modify any of the characteristics without notice, in a constant effort to improve the quality of its products. GBD5-02015 (KM44) 02/16 Basic terminal block DESCRIPTIVE Kohler Co. Provides one-source responsibility for the generating system and accessories The generator set and its components are prototype- tested, factory-built, and production-tested A one-year limited warranty covers all systems and components Mechanic governor Mechanically welded chassis with antivibration suspension Main line circuit breaker Radiator for core temperature of 48/50°C max with mechanical fan Protective grille for fan and rotating parts (CE option) 9 dB(A) silencer supplied separately Charger DC starting battery with electrolyte 12 V charge alternator and starter Delivered with oil and coolant -30°C Manual for use and installation 62

Modele GE - Kohler Power · 2016-03-21 · The control unit can be used as a basic terminal block for connecting a control box. Offers the following functions: emergency stop button,

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Modele GE - Kohler Power · 2016-03-21 · The control unit can be used as a basic terminal block for connecting a control box. Offers the following functions: emergency stop button,

KM44 Engine type S4S-DTAlternator type AT00500TPerformance class G2

50400/230APM303

GENERAL CHARACTERISTICS Frequency (Hz)Voltage (V)Standard control panelOptional control panelOptional control panel

DEC4000

POWERESP PRP

VoltagekWe kVA kWe kVA

Standby Amps

200/115 35 44 32 40 127240 TRI 35 44 32 40 106230 TRI 35 44 32 40 110220 TRI 35 44 32 40 115220/127 28 35 25 32 92415/240 35 44 32 40 61400/230 35 44 32 40 64380/220 35 44 32 40 67

DIMENSIONS COMPACT VERSIONLength (mm) 1700Width (mm) 896Height (mm) 1223Dry weight (kg) 680Tank capacity (L) 100

DIMENSIONS SOUNDPROOFED VERSIONCommercial reference of the enclosure M127

2080960141592010074

Length (mm)Width (mm)Height (mm)Dry weight (kg)Tank capacity (L)Acoustic pressure level @1m in dB(A) Sound power level guaranteed (Lwa)Acoustic pressure level @7m in dB(A)

91

POWER DEFINITIONPRP : Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO 8528-1. ESP : The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO 8528-1. Overload is not allowed

TERMS OF USEAccording to the standard, the nominal power assigned by the genset is given for 25°C Air Intlet Temperature, of a barometric pressure of 100 kPA (100 m A.S.L), and 30 % relative humidity. For particular conditions in your installation, refer to the derating table.ASSOCIATED UNCERTAINTYFor the generator sets used indoor, where the acoustic pressure levels depend on the installation conditions, it is not possible to specify the ambient noise level in the operating and maintenance instructions. You will also find in our operating and maintenance instructions a warning concerning the air noise dangers and the need to implement appropriate preventive measures.

This document is not contractual - Kohler Co. reserves the right to modify any of the characteristics without notice, in a constant effort to improve the quality of its products. GBD5-02015 (KM44) 02/16

Basic terminal block

DESCRIPTIVEKohler Co. Provides one-source responsibility for the generating system and accessoriesThe generator set and its components are prototype- tested, factory-built, and production-tested A one-year limited warranty covers all systems and

components Mechanic governor Mechanically welded chassis with antivibration

suspension Main line circuit breaker Radiator for core temperature of 48/50°C max with

mechanical fan Protective grille for fan and rotating parts (CE option) 9 dB(A) silencer supplied separately Charger DC starting battery with electrolyte 12 V charge alternator and starter Delivered with oil and coolant -30°C Manual for use and installation

62

Page 2: Modele GE - Kohler Power · 2016-03-21 · The control unit can be used as a basic terminal block for connecting a control box. Offers the following functions: emergency stop button,

KM44 ENGINE CHARACTERISTICS

MITSUBISHI

S4S-DT

Turbo L 4 3.33

N/A 94.00 x 120.00

17 : 1

+/- 2.5%

9.17

GENERAL ENGINE DATA Engine model

Engine type

Air inlet

Cylinders arrangement

Number of cylinders

Displacement (L)

Air coolant

Bore (mm) x Stroke (mm)

Compression ratio

Speed (RPM)

Pistons speed (m/s)

Maximum stand-by power at rated

RPM (kW)

Frequency regulation, steady state (%)

BMEP (bar)

Governor type Mechanical

COOLING SYSTEMRadiator & Engine capacity (L) 9.5

Max water temperature (°C) 100

Outlet water temperature (°C) 93

Fan power (kW) 0.7

1.1

10

Fan air flow w/o restriction (m3/s) Available restriction on air flow (mm H2O)Type of coolant Glycol-Ethylene

Thermostat modulating range HT (°C) 76.5-90

N/A

N/A

N/A

EMISSIONS Emission PM (g/kWh)

Emission CO (g/kWh)

Emission HC+NOx (g/kWh)

Emission HC (g/kWh) N/A

550

120

EXHAUSTExhaust gas temperature @ ESP 50Hz (°C)

Exhaust gas flow @ ESP 50Hz (L/s)

Max. exhaust back pressure (mm H2O) 680

FUELConsumption @ 110% load (L/h) 10.9

Consumption @ 100% load (L/h) 9.6

Consumption @ 75% load (L/h) 7.3

Consumption @ 50% load (L/h) 5.1

Maximum fuel pump flow (L/h) 36

10

1

5

0.12

OILOil capacity (L)

Min. oil pressure (bar)

Max. oil pressure (bar)

Oil consumption 100% load (L/h)

Oil sump capacity (L) 9

39

6

HEAT BALANCEHeat rejection to exhaust (kW)

Radiated heat to ambient (kW)

Heat rejection to coolant (kW) 31.7

250

AIR INTAKEMax. intake restriction (mm H2O) Intake air flow (L/s) 45

This document is not contractual - Kohler Co. reserves the right to modify any of the characteristics without notice, in a constant effort to improve the quality of its products. GBD5-02015 (KM44) 02/16

1500 6.00

41.9

Page 3: Modele GE - Kohler Power · 2016-03-21 · The control unit can be used as a basic terminal block for connecting a control box. Offers the following functions: emergency stop button,

KM44ALTERNATOR CHARACTERISTICS

GENERAL DATA Alternator type AT00500TNumber of Phase Three phasePower factor (Cos Phi) 0.8Altitude (m) 0 to 1000Overspeed (rpm) 2250Number of pole 4Capacity for maintaining short circuit at 3 ln for 10 s Yes

Insulation class H T° class(H/125°), continuous 40°C H / 125°K T° class, standby 27°C H / 163°KAVR Regulation YesTotal Harmonic Distortion in no-load DHT (%) 3.0

Total Harmonic Distortion, on load DHT (%)

1.6

Wave form : NEMA=TIF <45Wave form : CEI=FHT <2Number of bearing 1Coupling Direct

1

200

Voltage regulation at established rating (+/- %)Recovery time (Delta U = 20% transient) (ms)Protection classTechnology

IP 23Without collar or brush

OTHER DATA Continuous Nominal Rating 40°C (kVA) 42.5Standby Rating 27°C (kVA) 48Efficiencies 100% of load (%) 88.4Air flow (m3/s) 0.2

Short circuit ratio (Kcc) 0.35

Direct axis synchro reactance unsaturated (Xd) (%) 333.3Quadrature-axis synchro reactance unsaturated (Xq) (%)Open circuit time constant (T'do) (ms) 1280

Direct axis transient reactance saturated (X'd) (%) 13.2589.914

28.4

Short circuit transient time constant (T'd) (ms) Direct axis subtransient reactance saturated (X''d) (%)Subtransient time constant (T"d) (ms)Quadrature-axis subtransient reactance saturated (X"q) (%)Subtransient time constant (T"q) (ms) 13Zero sequence reactance unsaturated (Xo) (%) 2.99Negative sequence reactance saturated (X2) (%) 21.22Armature time constant (Ta) (ms) 30No load excitation current (io) (A) 0.83Full load excitation current (ic) (A) 2.29

24.3

160

Full load excitation voltage (uc) (V)Engine start (Delta U = 20% perm. or 50% trans.) (kVA)Transient dip (4/4 load) - PF : 0,8 AR (%) 14.01No load losses (W) 935Heat rejection (W) 4462

DIMENSIONS

M127 DW 2160

96615821100

23074

CONTAINMENT DWCommercial reference of the enclosure Length (mm)Width (mm)Height (mm)Dry weight (kg)Tank capacity (L)Acoustic pressure level @1m in dB(A) Sound power level guaranteed (Lwa) Acoustic pressure level @7m in dB(A)

91

This document is not contractual - Kohler Co. reserves the right to modify any of the characteristics without notice, in a constant effort to improve the quality of its products. GBD5-02015 (KM44) 02/16

108.4

Unbalanced load acceptance ratio (%) 100

62

Page 4: Modele GE - Kohler Power · 2016-03-21 · The control unit can be used as a basic terminal block for connecting a control box. Offers the following functions: emergency stop button,

KM44CONTROL PANEL

APM303, comprehensive and simple DEC4000, ergonomic and user-friendly

This document is not contractual - Kohler Co. reserves the right to modify any of the characteristics without notice, in a constant effort to improve the quality of its products. GBD5-02015 (KM44) 02/16

The APM303 is a versatile unit which can be operated in manual or automatic mode. It offers the following features:Measurements:phase-to-neutral and phase-to-phase voltages, fuel level(In option : active power currents, effective power, power factors, Kw/h energy meter, oil pressure and coolant temperature levels)Supervision:Modbus RTU communication on RS485Reports:(In option : 2 configurable reports)Safety features:Overspeed, oil pressure,coolant temperatures, minimum and maximum voltage, minimum and maximum frequency (Maximum active power P<66kVA)Traceability:Stack of 12 stored eventsFor further information, please refer to the data sheet for the APM303.

The highly versatile DEC4000 control unit is complex yet accessible, thanks to the particular attention paid to optimising its ergonomics and ease of use. With its large display screen, buttons and scroll wheel, it places the accent on simplicity and communication.

The DEC4000 offers the following functions:

Electrical measurements: voltmeter, frequency meter, ammeter.

Engine parameters: working hours counter, oil pressure, coolant temperature, fuel level, engine speed, battery voltage.

Alarms and faults: oil pressure, coolant temperature, failure to start, overspeed, alternator min./max., battery voltage min./max., emergency stop, fuel level.

Ergonomics: wheel for navigating around the various menus.

Communication: remote control and operation software, USB connections, PC connection.

For more information on the product and its options, please refer to the sales documentation.

Page 5: Modele GE - Kohler Power · 2016-03-21 · The control unit can be used as a basic terminal block for connecting a control box. Offers the following functions: emergency stop button,

The control unit can be used as a basic terminal block for connecting a control box.

Offers the following functions:

emergency stop button, customer connection terminal block, CE.

Basic terminal block

KM44CONTROL PANEL

This document is not contractual - Kohler Co. reserves the right to modify any of the characteristics without notice, in a constant effort to improve the quality of its products. GBD5-02015 (KM44) 02/16