54
MODEL:GM37305 PRODUCT SIZE(LxWxH):242x392x237cm PLEASE READ CAREFULLY BEFORE ASSEMBLY Assembly Instructions MODEL: Veranda vegg

MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

MODEL:GM37305PRODUCT SIZE(LxWxH):242x392x237cmPLEASE READ CAREFULLY BEFORE ASSEMBLY

Assembly InstructionsMODEL: Veranda vegg

Page 2: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

CONTENTS

1. Assembly Advice ................................................................Page 12. Product Features ................................................................Page 2 - 33. Part Lists .............................................................................Page 4 - 74. Roof Vents Assembly ..........................................................Page 8 - 126. Doors Assembly ..................................................................Page 13 - 197. Base Assembly ....................................................................Page 20 - 218. Framework Assembly ..........................................................Page 22 - 439. Panels Assembly .................................................................Page 44 - 52

Page 3: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

11

Free ToolFree ToolFree ToolFree Tool

Assembly and Maintenance Advice1. For safety purposes, we strongly recommend that this product is assembled by at least two people.2. Some components have sharp metal edges. Please be careful when handling metal components. Please wear gloves, shoes and safety goggles during assembly.3. Lay all of the components on a soft carpet or blanket to avoid any scratches or damages.4. DO NOT climb or stand on the roof. Heavy articles should not be leaned against the greenhouse.5. Keep the roof and gutter clear of snow, dirt & leaves. Allowing snow to build up on the roof may damage the product.6. Unlike steel, if the paint finish is scratched this will not harm the aluminium underneath.7. When your product needs cleaning, use a mild detergent solution and rinse with cold clean water. Do not use acetone, abrasive cleaners or strong detergents to clean the panels.

Tools Provided:

Component required but not provided:

Neutral Silicone Sealant

Tools Required when Assembly (Not Provided)

Assembly at least by two Persons

Page 4: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

2

30mm120mm 71mm

72mm83mm

8&10mm 8&10mm8&10mm

(8/10mm)PC Panel

4&6mm 4&6mm4&6mm

(4/6mm)Glass Panel

* If you are glazing this greenhouse with glass you will need to slide the rubber gaskets (provided) into the bar capping.

Functions and Features:1. Compared with traditional greenhouses, this exciting new product features many significant improvements. The hollow box profile aluminium framing is much stronger than other greenhouses and it can withstand much greater pressure. Wind resistance up to 12th typhoon (40M/S or 120KM/H). Weight Support 80KGS/M2,

Snow load capability over 40CM.

Gutter Profile Post

Traditional Greenhouse New Large Lean to Greenhouse

2. A great improvement for this new greenhouse is bigger bar capping and thicker connectors, which are much neater and stronger. Another benefit is that these greenhouses can be glazed with glass or polycarbonate of varying thicknesses.

Page 5: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

Expansionscrew/Concreteground

3

3. Base anchor brackets are included as standard with expanding bolts to ensure a secure fixing into concrete or paving. Alternatively, you can use the brackets to fix into a timber base with wood screws.

5. The strong two part eaves beam includes an integral gutter. Downpipes are also included as standard so you can collect rainwater.

7. Remove approximately 2 inches of film from all sheet edges before installing and remove all film immediately after the construction is completed. Please ensure that the side with the white film faces outwards.

4. Our unique frame connectors (2.5mm thick) make much stronger joints than conventional greenhouses.

Steel bar/Lawn land

Manual opener Automatic opener

GM80001

6. Manual window handles are included as standard with the roof vents. If required, automatic roof vent openers are available as an inexpensive optional extra.

Page 6: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

4

L26A 2

L26B

L26C

2

4

L01B 2

L06 1

L07 1

D 1

E 1

F 1

G 1

L08A 2

L08B

L10

A

B

J01

1

1

2

2

4

PART NO QTY

L01A 2

L01C 2

L09 1

L14 1

GM37305(ALU. Box No.1)

ALU. Box No. 1

Page 7: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

5

GM37305

ALU. Box No. 2

(ALU. Box No.2)

L23B 4

L02B 4

L23C 22

L23D 12

L23A 5

L02A 3

L23N 2

L02K 12

L24A 12

L25A 2

L25B 2

L25C 2

L25D 2

L25E 2

L25F 2

L24D 1

L24E

L24F

L24G

1

1

1

L24B

L24C

2

4

PART NO QTY

L02D 1

K 42

M 4

L02E

L02F

L02G

1

1

1

L23E 10

L23F 6

Page 8: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

6

ALU.BoxNo.3

GM37305(ALU.BoxNo.3)

L23C 14

1L12D

1L12F

L11A 4

L11D 7

14L12K

1L12E

1L12G

L11C 2

3L12A

L11E 2

L11B 4

4L12B

PART NO QTY

L02K 2

PART NO QTY

W10 2

GM80001 2

8Ø4X10Z03

Automatic Openers (Optional)

K 4

W08 2

10Ø4X14DZ02

S01M6X12 9

Z 4

M03M6 9

W03 2

J02R/L 1/1

J03R/L 1/1

J06 2

J07 2

J08 2

2Ø4X14Z01

J05 2

W06 2

Windowx2pcs

PART NO QTY

L13 1

L16A 8

L17 2

L18A 2

L16B 8

L18B 1

L18C 1

L18D 4

PART NO QTY

8

8Ø4X40Z04

D 4S02 4M8X30M02M8 4

L11H 8

L11J 8

J

DoorPART NO QTY

PART NO QTY

S03 12M8X60

W05 12

Base

PART NO QTY

L19A 4

L19B 2

L20 2

L11F 4

L11G 4

W06 2

J 8

4Z03

Ø4X10

Y10 2

L15A 2

4Ø4X14DZ02

W12 2

W13 2

M01M6 3

Page 9: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

GM37305

PC/Glass

7

PART NO QTY

Y1 1

Y2 6

Y3 1

Y4 1

Y7 5

Y6 6

Y5 1

Y4

Y2

Y8

Y2

Y13

Y2

Y4

Y2

Y8

Y2

Y13

Y2

Y6 Y6

Y6 Y6

Y6 Y6

Y11 Y11

Y11 Y11

Y7 Y9

Y7 Y9

Y7 Y9

Y7

Y7 Y10

Y10

Y8 1

Y9 3

Y10 2

Y11 4

Y13 1

(PC/GLASS. Box)

Page 10: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

PART NO QTY

L19A 4

L19B 2

L20 2

L11F 4

L11G 4

W06 2

J 8

8

L20

L19B

L19A

L19A

B

B

B

BY10

L11FL11F

L11G

L11GW06

4Z03

Ø4X10

Y10 2

L15A 2

4Ø4X14DZ02

L15A

Roof Vents Assembly 2PCS

Page 11: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

9

L20

L19B

L19A

L19A

J

J

J

J

1

1

2

2

L20J

L19AJ

L19A

L19B

1

2

Push down the button on connector J before inserting it into the end of the frame profile.

After connector J has been fitted, use the hole in the profile to tighten the connector in place.

Page 12: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

10

L11G

L11G

L11FL11F

Y10

Y10First the glazing panel Y10 should be loosely retained by the bar capping profiles L11F and L11G. Next tap the bar capping gently into position with a rubber mallet.

Page 13: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

11

Z03Z03

W06

Y10

Y10

Fix the W06 vent handles using Z03 screws.

Page 14: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

12

Y10

L15A

Z02

1

2

Z02

L15A2 1 2

Fill the gap with silicone sealant on 4 sides to avoid any leaking.

Page 15: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

PART NO QTY

L13 1

L16A 8

L17 2

L18A 2

L16B 8

L18B 1

L18C 1

L18D 4

PART NO QTY

8

PART NO QTY

Y11 4

8Ø4X40Z04

D 4S02 4M8X30M02M8 4

13

L11H 8

L11J 8

J

Door Assembly

Page 16: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

14

L18D

L16A

L16A

L16A

L16A

L17

L16B

L16B

L18D

J

JJ

J

L18A

L18B

Left Door

S02x2pcs

L18D

L16A&B

L18A&B&D

L17

L16A

L16A

1

1

1

1

22

1

2 Z04

L18A/L18B

L16B

L17

L16A

L16A

then assemble the door frames using connector J, as shown in the sketches below.

Put L16A into L17 and L18D and put L16B into L18A and L18B,

Push down the button on connector J before inserting it into the end of the frame profile.

Tighten L17 throughL18A/L18B with Z04.

After connector J has been fitted, use the hole in the profile to tighten the connector in place.

Page 17: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

15

Y11

Y11

L11H

L11H

L11H

L11H

L11J

L11J

Y11 Y11

First the glazing panels should be loosely retained by the bar capping profiles L11H and L11J. Next tap the bar capping gently into position with a rubber mallet,

Page 18: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

16

M2

H100mm 100mm

29mm 29mm

L13

1 1 2

3

11

2

3

After Assembly

Slide 2xS02 into L18D, positioned 100mm away from each edge. Secure S02 using M02 bolts, then rotate the wheels to ensure free movement.

14.4mm

L13

L13

14.4mm

Attention: make sure you leave 14.4mm space on both ends when you install L13

Page 19: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

17

L18D

L16A

L16A

L16A

L16A

L17

L16B

L16B

L18D

J

JJ

J

L18C

L18A

S02x2pcs

L18D

L16A&B

L18A&B&D

L17

L16A

L16A

1

1

1

1

22

1

2 Z04

L18A/L18C

L16B

L17

L16A

L16A

Right Door then assemble the door frames using connector J, as shown in the sketches below.

Put L16A into L17 and L18D and put L16B into L18A and L18C,

Push down the button on connector J before inserting it into the end of the frame profile.

Tighten L17 throughL18A/L18C with Z04.

After connector J has been fitted, use the hole in the profile to tighten the connector in place.

Page 20: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

18

Y11 Y11

Y11

Y11

L11H

L11H

L11H

L11H

L11J

L11J

First the glazing panels should be loosely retained by the bar capping profiles L11H and L11J. Next tap the bar capping gently into position with a rubber mallet,

Page 21: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

19

M2

H100mm 100mm

29mm 29mm

1 1

11

After Assembly

* This is the method ofadjusting the door height.

Slide 2xS02 into L18D, positioned 100mm away from each edge. Secure S02 using M02 bolts, then rotate the wheels to ensure free movement.

Page 22: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

ab

a b=

ab

a b=

20

It is essential the dimensions a = b are the same to ensure the base is square.Expansion bolt in concrete

Steel pegs in soil or wood

Support at the corners only is inadequate.

Page 23: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

21

106.3

PART NO QTY

S03 12M8X60

W05 12

2254mm

3790

mm

4409

.6m

m

4409.6mm

325 768 768 325

325

1536

1536

325

325 768 768 325

325

768

325

This size is the inner specification of the product,

Expansion bolts assembly

Page 24: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

22

12

4

3

L08B

L08A

L08A

L10

1 2

43

L08B

L08A

A

J01

A

L08B

L08A

J01

J01 J01L10L10

L08AL08A

L08A

PART NO QTY

L08A 2

L08B

L10

A

B

J01

1

1

2

2

4

First lay out the aluminium profiles, connectors and anchor brackets approximately in place.

Make sureyou payclose attentionto the directionof the pins

Assemly L08A, L08B and L10 with connecter A and B. Insert connector A/B into L08A/L08B and L10, tight the bolts with the special spanner (provided) when the connector A/B is in the right position.Anchor bracket J01 must be assembled at the same time.

Page 25: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

23

L01C

L01C

L01A

L01A

1

2

2

1

L01C

A

J01

L01CB

J01

L01A

B

J01

L10

L01A

A

J01

1 2

3 4

PART NO QTY

L01A 2

L01C 2

Make sureyou payclose attentionto the directionof the pins

Assembly L01A/L01C with connector A/B,insert connector A/B into L01A/L01C, tight the bolts with the special spanner when they are in the right positions.

Page 26: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

24

1 2

43

L06G

L01B

L01C

L06F

L01B

L01C

L01B

E

L01A

L07

L01B

D

L01A

L07

PART NO QTY

L01B 2

L06 1

L07 1

D 1

E 1

F 1

G 1

L061

2

L01B

L01B

L07

3

4

Make sureyou payclose attentionto the directionof the pins

Install L01B and L06 using connector G/F, insert connector G/F into L01B and L06, tight the bolts with the special spanner when they are in right positions. Then connect them to L01C, using the other end of connector G/F, tight the bolts when they are in right positions.

Install L01B and L07 using connector D/E, insert connector D/E into L01B and L07, tight the bolts with the special spanner when they are in right positions. Then connect them to L01A, using the other end of connector D/E, tight the bolts when they are in right positions.

Page 27: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

25

L26A

L26A

L26B

L26B

L26C

L26C

L26CL26C

L08B

L06

L08A

L08A

L06

L01C L01C

L01C

L01C

L08A L08B L10

PART NO QTY

L26A 2

L26B

L26C

2

4

L26C

L26A

L26A

L26C

L26C L26BL26B L26C

Please pay attention to the direction

Tap the bar capping L26A into L01C, L26B into L08A, and L26C into L06, L10 and L08B gently with

a rubber mallet as shown above.

L10

Page 28: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

26

L24B

L24C

L24C

L24B

L24C

L24C

L23CL23C

L23CL23C

L23CL23C

51mm51mm

51mm51mm

50mm 50mm50mm 50mm

L08A

L01B

L08A

L01B

PART NO QTY

L23C 6

L24B

L24C

2

4

L01BL01B

L08AL08A

L23C

L23C

L24B

L24CL24B

L24C

Tap the bar capping L24C/L24B into L01B gently with a rubber mallet. Make sure you leave 51mm between each two L24C or L24C and L24B in the middle for later assembly.

L01B

Tap the bar capping L23C into L08A gently with a rubber mallet. Make sure you leave 50mm between each two L23C in the middle for later assembly.

L08A

Page 29: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

27

M

L02D&E&F&G*L01B

M

1

L01B

K

L02D&E&F&G*

KL23C

L23C

L08A

2

PART NO QTY

L02D 1

K 4

M 4

L02E

L02F

L02G

1

1

11

1

11

22

22

L02E

L02G

L02DL02F

Put connector K into the slot of L08A and M into the slot of L01B, turn their direction until they go into the holes on L02D/L02E/L02F/L02G. Tight the bolts in the connector K and M with the spanner. Pay attention to the direction on the spanner.

L08A

L01B

Slide in Tight it up

Slide in Tight it up

Page 30: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

28

L02GL02E

L02D

L02F

L24E

L24G

L24DL24F

L24D&E&F&G

PART NO QTY

L24D 1

L24E

L24F

L24G

1

1

1

L24DL24F

L24E

L24G

Tap the bar capping L24D into L02D,L24E into L02E, L24F into L02F, L24G into L02G, gently with a rubber mallet.

Page 31: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

29

50mm50mm

L25A&B&C&D&E&F

L24AL02D&E&F&GL01C L01A

PART NO QTY

L24A 12

L25A 2

L25B 2

L25C 2

L25D 2

L25E 2

L25F 2

L24AL24A

L25F

L25D L25B

L25F

L25D L25BL25E

L25CL25A

L25E

L25C L25A

L02GL02E

L01A

L01C

L02FL02D

L01A

L01C

L24A

L25AL25B

L25CL25D

L25EL25F

L24A

L25AL25B

L25CL25D

L25EL25F

Tap the bar capping L24A,L25A,L25B,L25C,L25D,L25E and L25F,into the corresponding aluminium profiles gently with a rubber mallet as above shown. Make sure you leave 50mm between the L24A and L25A/L25B/L25C/L25D/L25E/L25F/in the middle,for later assembly of L02K. Do the same on the other sides.

Page 32: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

30

PART NO QTY

L02K 6

K 12

L02K

L24A

L25A&B&C&D&E&F

K

K

L02KL02K

L02KL02K

Put connector K into the slot of L01A,L01C,L02D,L02E,L02F,and L02G, turn their direction until they go into the holes on L02K. Tight the bolts in the connector K with the spanner.

Slide in Tight it up

Page 33: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

31

50mm50mm 50mm

50mm50mm

50mm

L23C

L23C

L23N

L07

L10

L07

L10

PART NO QTY

L23C 6

L23N 2

L23C

L23N

L23N

L23C

Tap the bar capping L23C and L23N into L10 and L07 gently with a rubber mallet. Make sure you leave 50mm between the two L23C or between L23C and L23N in the middle,for later assembly of L02A.

L10

L07

Page 34: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

32

L02A

KL23E&N

L23N&E

L10

1 2L07

L02A

K

PART NO QTY

L02A 3

K 6

L02AL02A

L02A

11 1

22 2

Install L02A (3PCS). Put connector K into the slot of L07 and L10, turn its direction until it goes into the hole on L02A. Tight the bolt in the connector K with the spanner.

Slide in Tight it up

Page 35: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

33

L23AL23A

L23A

L23A

L02A

PART NO QTY

L23A 3

Tap the bar capping L23A into L02A gently with a rubber mallet.

Page 36: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

34

L23D

L23DL23D

L23AL02AL02A

L02A L01A

L02A

50mm50mm

L23D

L23D

L02BL01B L01B

50m

m

50m

m

50m

m

50m

m

50m

m

50m

m

PART NO QTY

L23A 2

L23D 12

L23D

L23D

L23DL23D

L23DL23D

L23A

Tap the bar capping L23A and L23D into L01A and L02A gently with a rubber mallet. Make sure you leave 50mm between the two L23D in the middle,for later assembly of L02K.

Page 37: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

35

L02K

L23D

L23D

K

K

PART NO QTY

L02K 3

K 6

L02K

L02KL02K

Put connector K into the slot of L01A and L02A, turn its direction until it goes into the hole on L02K. Then, tight the bolt in the connector K with the spanner.

Slide in Tight it up

Page 38: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

36

50mm 50mm

50mm 50mm

50mm

50mm 50mm

50mm

L23CX10pcs

L06

L07

L07L06

PART NO QTY

L23C 10

L23C

Tap the bar capping L23C(10PCS) into L06 and L07 gently with a rubber mallet. Make sure you leave 50mm between the two L23C in the middle,for later assembly of L02B.

Page 39: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

37

KL02B

L23CL23C

L07

K

L06

L02BKL23C

1 2

PART NO QTY

L02B 4

K 8

2

L02B

1

L02BL02B

L02B

Install L02B (4PCS). Put connector K into the slot of L06 and L07, turn its direction until it goes into the hole on L02B. Then tight the bolt in the connector K with the spanner.

Slide in Tight it up

Page 40: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

38

L02B

L23B

PART NO QTY

L23B 4

L23BL23B

L23BL23B

Tap the bar capping L23B into L02B gently with a rubber mallet.

Page 41: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

39

L23E

L23F

L23EL23E

L23F

L23EL23E

L23F

50mm

50mm

50mm50mm

50mm50mm

L01B

L01BL02B

50mm50mm

L23F

L23E

L02A

L02BL01B L01B

PART NO QTY

L23E 10

L23F 6

L23EL23E

L23EL23E

L23EL23F

L23FL23F

Tap the bar capping L23E and L23F into L01B and L02B gently with a rubber mallet. Make sure you leave 50mm between the two L23E or L23E and L23F in the middle as shown above,for later assembly of L02K.

Page 42: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

40

K

L02K

L23E L23FK

PART NO QTY

L02K 3

K 6

L02KL02K

L02K

Assembly L02K. Put connector K into the slot of L01B and L02B, turn its direction until it goes into the hole on L02K. Then tight the bolt in the connector K with the spanner.

Slide in Tight it up

Page 43: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

41

PART NO QTY

L23C 12

L23C

L02K

L23CL23C

L23C

L23CL23C

L23C

L23C

L23CL23CL23C

Tap the bar capping L23C into the corresponding aluminium profiles gently with a rubber mallet as shown above.

Page 44: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

42

PART NO QTY

L02K 2

K 4

L02K

L23E L02BK

K

W10

L02K

PART NO QTY

W10 2

L02KL02K1 1 1 1

Assembly L02K. Put connector K into the slot of L02B, turn its direction until it goes into the hole on L02K. Then tight the bolt in the connector K with the spanner.Make sure L02K must connect to L23F closely.

Attention: If you install automatic openers, make sure you slide W10 into L02K before you install L02K.

Page 45: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

43

PART NO QTY

L23C 2

L23C

L02K

L23CL02K

cut 42mm

338mm

338mm

W10

L23CL23C

Tap the bar capping L23C into L02K gently with a rubber mallet.

Attention: If you install automatic openers, please cut L23C into 2pcs (Length: 338MM/PC)Tap them into L02K gently with the a rubber mallet, and leave 42mm space for W10.

Page 46: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

44

Y1 Y3

Y2 Y2 Y2

1

1

5

5

9

9

PART NO QTY

L11B 1

1L12D

1L12F

Y2 4

L11A 1

L11C 1

L11D 3

3L12K

Y1 1

Y3 1

Y5 1

Y5

L11B

L11AL12D

L12F

L12KL12K

L12K

L11DL11D

L11D

L11C

2

3

4

6

7

8

10

11

12 13

14

Install the panels and aluminum bar capping in order as shown above, tap these bar cappinginto the channels of each position properly with a rubber hammer.

Page 47: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

45

PART NO QTY

L11B 1

1L12E

1L12G

Y2 4

L11A 1

L11C 1

Y4Y8Y13

Y2Y2Y2

1

1

2

3

45

5

9

9

6

7

8

10

11

1213

14

L11D 3

3L12K

Y4 1

Y8 1

Y13 1

L11B

L11AL12E

L12G

L12KL12K

L12K

L11DL11D

L11D

L11C

Install the panels and aluminum bar capping in order as shown above, tap these bar cappinginto the channels of each position properly with a rubber hammer.

Page 48: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

46

PART NO QTY

L11D 1

3L12A

3L12K

Y6 6

Y6

Y6

Y6

Y6

Y6

Y6L11A

L11A

L12A

L12A

L12K

L12KL12K

L11E

L11EL11D

Y7

Y7

L11A 2

L11E 2

Y6

Y6

Y6Y6

Y6Y6L11A

L11A

L12AL12A

L12K

L12KL12K

L11E

L11EL11D

Install the panels and aluminum bar capping in order as shown above, tap these bar cappinginto the channels of each position properly with a rubber hammer.

Page 49: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

47

PART NO QTY

L11B 2

4L12B

5L12K

Y7 5

L09 1

Y9 3

Y7Y7

Y7Y7

Y7Y9Y9

Y9

L12K

L12KL12K

L12KL12K

L09

L11B

L11B

L12BL12B

L12BL12B

Install the roof panels and aluminum bar capping in order as shown above, tap these bar cappinginto the channels of each position properly with a rubber hammer.

Page 50: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

48

Fill the silicone sealant on the places shown above to avoid any water leaking.

Page 51: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

49

W06W08 M03

L07L07

Z

W08

M03

S01

2

L15A

L06

1

L15A

Z02x2

PART NO QTY

W08 2

4Ø4X14DZ02

S01M6X12

M03M6

4

4

Z 4

Z03

GM80001

L02K

L19B

W10

L02K

Z03GM80001

2PART NO QTY

GM80001 2

8Ø4X10Z03

1 1

2

Windowx2pcs

S01

Z

*Ensure the manual vent is closed as shown.

Slide the window vent along the groove in the L06 and fix it in the correct position using Z02 screws.

Use a screw S01 to pass over Part Z,and then put part Z (2pcs) into the slot of L07, turn its direction until it can fix W08. Adjust the position of W08 until the manual vent can be closed as shown, then lock the S01 tight.

Way to assembly automatic openers

Page 52: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

Left Door

Right Door

1L14

50

DM03

1

L14

L09

L18D

PART NO QTY

L14 1

M03M6 5

S01M6X12 5

S02X3pcs

HL14

L14

W12 2

W13 2W12

W13

S01

M03

W12

M01M6 3

L14

Door

M03M01

Use a bolt S01 to pass over W12, and then slide W12 (2pcs) into the channel of L14, fix them using W13 and M03 loosely.

Rotate D, the roller wheels, to adjust the height of the door so it does not bind or rub on the bottom track.

Adjust the positions of the two W12 until the doors are closed properly as shown, then lock the S01 tight.

Page 53: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

51

PART NO QTY

W03 2

6Ø4X14DZ02

J03R/L J02R/L

W03Z02

1 2

J02R/L 1/1

J03R/L 1/1

22

11

Install the anchor brackets J03R/L and J02R/L using screw Z02.

Page 54: MODEL: Veranda vegg · L18A/L18C with Z04. After connector J has been fitted, use the hole in the profile to tighten the connector in place. 18 Y11 Y11 Y11 Y11 L11H L11H L11H L11H

11

J06

J06

J07

J08

Z01

52

2

PART NO QTY

J06 2

J07 2

J08 2

2Ø4X14Z01

J06

J05

L07L01B

J02R/L

J05 2

1

3

2

1

3

2

Drill a hole in L01A and L01B, approximately 3.2mm diameter and 700mm up from the bottom. Fix the J08 downpipe bracket with Z01 screws and then clip the J06 downpipe into the J08 bracket.

Fill some silicone sealantaround J02, J07 and J06 to avoid water leaking.

Fill some silicone sealantaround the downpipe bends to avoid water leaking.