The sr-2 is the second generation of the Hanwell Smart Receiver. Itis a network enabled receiver, designed for collectingenvironmental monitoring data from multiple points within a site,or across multiple sites. In addition, it can be upgraded to atransceiver which both receives and retransmits the data. It usesstandard TCP/IP communications protocols for speedy datahandling. The network traffic generated is very low and data isautomatically sorted and filed.
This multipoint operation can be further expanded, with the use ofoptional GPRS, and used on a larger national or internationalbasis. See the diagram overleaf for some potential ways of usingthe sr-2, or contact Hanwell to discuss your site specificrequirements.
In addition to receiving data from the rl-2000, rl-4000, rl-5000 andrl-8000 ranges of sensors, the unit can also read hard-wiredsensors and, optionally, be fitted with up to eight on-boardprobes. Each sr-2 can handle data from up to 253 sensors, and upto 16 sr-2s can be run on a single system bringing it to a total of4048 sensors. The sr-2 supports Hanwell’s standard and extendedtransmission data formats.
The sr-2 logs all received data in its on-board 512kb memory. TheRadiolog software continually interrogates the sr-2 for the most
recent data, and downloads the data according to user-definedlogging periods to the server or operating PC. Software users canview live and historic data, produce out of spec and summary reportsand set alarms on both the data levels and the rate of change.
In addition to the data readings from the sensors, the sr-2 can logthe corresponding Received Radio Signal Indicators (RSSI) whichreveal the strength of radio reception of each Sensor. As well asbeing logged, the RSSI is indicated on the front LCD along withother status information. An optional remote Receiver can beconnected to improve radio reception in difficult areas.
The sr-2 is designed to be in constant communication with thesoftware but has user-configurable fallback behaviour in the eventof network or power failure. An on-board battery provides a UPSwith 2.3A/hour life to carry it through up to 12 hours’ powerdisruption (larger external UPSs are available as an optionalextra).
Alarm relays are included: these can indicate that the readings areout of specification, and can be optionally set to indicate anetwork failure. A MS BUS connection allows the sr-2 to drive theHanwell MS1000 environmental control system.
Model:
Industrial ApplicationsProduct Name:
Product Code:SR2
Smart Receiver (Mk2)
See diagram overleaf
RoHS Compliant
Transmitter 1Not available in US, 2US only
Dimensions 300 x 200 x 85mm
Weight 1.2kg
Power Supply Options 110V AC or 240V AC. On-board 12V battery back-up supplying 2.3A/hr
Case Material(s) Powder coated mild steel
Operating Humidity Range 10…90% RH, non-condensing
Operating Temperature Range 5…40C (Temperature compensated range)
Radio Specification
FF1 F11 SF1 HP2
Radio Frequency 434.075 MHz 433.920MHz 433.875 to 434.650MHz in 25 KHz increments Synthesized
Radio Power 10mW 10mW 10mW Programmable
Radio Range 2 miles over open ground
Outputs
Alarm Outputs 1 x nominal 12V, 2 x changeover relays (energised when no alarms exist)
MSBUS 4 core signal cable
Accessories (e.g. mounting brackets, remote probe etc)
Codes Description
RX-xx Remote receiver – please specify the frequency required
Y306-05-03 Thermistor probe on 5m cable with bare ends suitable for wiring into the sr-2’s on-board probe inputs
Y404-05-03 Humidity probe on 5m cable with bare ends, as above.
Y405-05-03 Combined thermistor & RH probe on 5m cable with bare ends, as above
ABR12/24 Alarm beacon, red strobe, 12/24V with bracket and 2m cable
SR2-E-7.0-UPS 7.0Ah external wall mounted UPS
SR2-E-15-UPS 15Ah external wall mounted UPS
Instrumentation for Science and Industry ISI sa-nv Rue du Doyenné 3 Dekenijstraat 1180 Brussels Tel +32 (0) 2 343 30 81 web : http:// www.isi-be.com mail : [email protected]
New from Hanwell is the rl5000 dpradiotelemetry transmitter, designed foruse withthe Radiolog 8 environmentalmonitoringsystem. The units are inIP65-rated cases andare suitable for usein tough environments.
Utilising an integral temperaturecompensated pressure sensor therl5000 differential pressure transmitterdelivers exceptional performance. Thesensor utilises a silicon, micromachined, stress concentrationenhanced structure to provide a verylinear output to the measured pressure.The ports are designed with matcheddead volumes. This series is intendedfor use with non-corrosive, nonionicworking fluids such as clean dry air, drygases and the like.
The media wetted materials are thesilicon diaphragm, glass filled nylon,RTV and alumina ceramic. Thetransmitter ID, transmission speed andcalibration data is programmed into itsonboard memory using Radiolog 8, asoftware package which automaticallyrecognises the type of unit connected tothe PC via the USB lead.
Fitted with a custom-designed LCD toindicate current readings, battery liferemaining and alarm conditions. Thereis an instantaneous display updatebutton located on the front panel.Pressure connections are made viaquick release Lemo pressureconnectors, which avoid damage to the
pressure sensor when disconnecting forcalibration.
The transmitter is typically powered bya 7.5V 2700mAh battery or 2 x LithiumC size 5 Ah that can be fitted by the user . The battery life will be dependant on thetransmission speed. Larger batterypacks are available, local power input isalso an option. An indicator on the LCDwill warn when the battery is low, andthe transmitter maintains a record ofwhen the battery has been changed.The rl-5000 range has been designed tocomply with the RoHS and WEEE EUdirectives, and carries the CE mark.
Product Code RL5001-xxx Series rl5000
1 Not available in US2 Only available in US
Typical Applications° Environmental monitoring° Warehouse monitoring° Pharmaceutical monitoring° Laboratory monitoring° Building monitoring & control° Event logging°T emporary monitoring
InstrumentDimensions: 197 x 106 x 60mmWeight: 300 gramsCase Material: ABSPower Supply: 7.5V 2700mAh or 2 x Lithium C sizeOp. Humidity Range: 0…95% RH, non-condensingOp. Temp. Range: -20 °C to +60 °C
SensorsCode DescriptionRL5001 Thermistor, PT100, Humidity, Linear
Radio*Radio Frequency: Fixed frequency modules
434.075 MHz1433.920 MHzSynthesised modules433.875 to 434.650 MHzin 25KHz increments1
458.650 MHz 2
Radio power: 10 mWRadio range: 3 km over open ground
Communications & SoftwarePC/Logger Interface: Standard USB A/ USB mini-BPC Software: 32bit Windows with
Radiolog 8.3 or laterMinimum O/S: Windows 2000, Windows XP,
Windows NT
AccessoriesCodeY055 USB communications leadW250 USB configuration tool
(required for users with Radiologsoftware earlier than 8.3)
rl5001 radio transmitter
Radiologger - Transmitter
ISI sa-nv - Instrumentation for Science and Industry (INTERCONTINENTAL SERVICES INC)Rue du Doyenné 3 Dekenijstraat 1180 Brussels – Belgium - Tel 02/ 343 30 81 Fax 343 12 05 mail : [email protected] web : www.isi-be.com
Model:
Industrial ApplicationsProduct Name:
Product Code:SR2
Smart Receiver (Mk2)
Network UserFor example, ahome worker
Network UserFor example,someone needingweekly reports
Network UserFor example,main systemadministrator
Network ServerCollects data fromall sr-2’s and isinterrogared byNetwork Users
Isolate mains supply before removing this cover. Live parts enclosed.
Isolate mains supply before removing this cover. Live parts enclosed.
Isolate mains supply before removing this cover. Live parts enclosed.
Local SiteOne or more sr-2’son a main siteconnected via LANpoints
Remote SitesOne or more sr-2’sfrom remote sitesvia LAN or WAN, forexample, off-site
Remote SitesNon-networkedsite connectedvia modem
LAN
LAN
or WAN
Modem
Interface
One system can comprise up to 16 separatesites but all data is treated the same way.
Instrumentation for Science and Industry ISI sa-nv Rue du Doyenné 3 Dekenijstraat 1180 Brussels Tel +32 (0) 2 343 30 81 web : http:// www.isi-be.com mail : [email protected]
The rl4001 & rl4002 are precisionthermistor temperature measuring andradio transmission devices. The rl4001has a single channel the rl4002 is dualchannel. The sensors are connectedvia 2 pin Lemo plugs and sockets.They allow wire-free monitoring of asite, with real time alarm notificationand historical analysis of data. Each4000 unit reads its on-board sensorsproviding accurate and reliableinformation about environmentalconditions. This data is transmitted, atuser-defined intervals, to the Radiologsystem where it is filed for analysis.
rl4000 series transmitters can be usedin accordance with GAMP and FDAregulations. The transmitters andsensors can be calibrated by the eitheruser or Hanwell staff on-site or atHanwell’s in-house calibrationlaboratory.
Transmitter ID number andtransmission rate are set in thetransmitter using a simple softwareprogram (free to download) and a USBcable. Each unit has an LCD screensimultaneously displaying the mostrecent readings taken and the predictedbattery life.The transmitter is poweredby a single 3.6V AA Lithium battery,which can be fitted by the user.
The battery life will be dependent onthe transmission rate set. An indicatoron the LCD will warn when the batteryis low, and the transmitter maintains a
record of when the battery was lastchanged.
Each 4000 series radio transmitter hasenough internal memory to store up to100000 readings and is in factcontinually logging guaranteeing 100%validity of the data. The 4000 series unitcan be downloaded via the high speedUSB connection directly into the PCsoftware (V8.4 or later only). The datalogged will be added to the radio data,providing a continuous history for thattransmitter.
The moulded case allows easy accessto the battery and USB socket, as wellas having slots to fit onto secure wallbrackets.
CFR21 part 11 compliant software isavailable. OQ & IQ templates areincluded, full on-site validation servicesare available.
The 4000 range has been designed tocomply with the RoHS and WEEE EUdirectives, and carries the CE mark.
Product Code RL4001-434.075* & RL4002-434.075*
Series rl4000
Typical ApplicationsMonitoring in: ° Fridge/Freezer monitoring° Laboratories° Hospitals° Pharmaceutical° Warehousing
InstrumentDimensions: 110 x 80 x 35mmWeight: 200 gramsPower Supply: 3.6 Volt AA Lithium batteryBattery Life: 18 monthsCase Materials: ABS & PCOperatingHumidity Range: 0…100% non-condensingOperating Temp Range: -20° to +60° CMemory Capacity: 100000 readings
Sensors TemperatureSensor: Precision thermistorRange: -40° to +70° CAccuracy: +/- 0.1° C between
-25° C to +50° C +/-0.3 elsewhereResolution: 0.1° C
Radio*Radio Frequency: 434.075MHz
433.920MHz (fixed)433.875 - 434.650MHz in 25KHz increments(synthesised)
Radio Power: 10 mWRadio Range: 3 km over open ground
AccessoriesCode:
Y119 Wall mounting security bracketY055 Setup communications cableG129 Replacement 3.6V Lithium AA
batteryCAL-T 3 point calibration between
-20 and +110C (single Ch)CAL-T-LOW 3 point calibration between
-90 and +110C (single Ch)CAL-T-2 3 point calibration between
-20 and +110C (dual Ch)CAL-T-LOW-2 3 point calibration between
-90 and +110C (dual Ch)
Single channel thermistor
Radiologger - Transmitter
Above:Detail of USB socket
Below:Optional wall mountingsecurity bracket
Instrumentation for Science and Industry ISI sa-nv Rue du Doyenné 3 Dekenijstraat 1180 Brussels Tel +32 (0) 2 343 30 81 web : http:// www.isi-be.com mail : [email protected]
The rl4106 radio transmitter is one of anew range of advanced temperatureand humidity radio transmitters. Theyallow wire-free monitoring of a site,with real time alarm notification andhistorical analysis of data. Each rl4106unit reads its on-board sensors toprovide accurate and reliableinformation about environmentalconditions. This data is transmitted, atuser-defined intervals, to the Radiologfor Museums system where it is filedfor analysis.
The rl4106 has two sensors as standard:a precision temperature probe and ahigh quality humidity probe. Thesesensors can be mounted internally tothe transmitter body, externally on thecase or remotely on a probe. Anadditional surface temperature probecan be added to check the dewpointmargins. These sensors can becalibrated by the users or at Hanwell’sin-house calibration laboratory.
The ID number and transmission rateare set in the rl4106 using a simplesoftware program (free to download)and a USB cable. Each unit has an LCDscreen simultaneously displaying themost recent readings taken and thepredicted battery life.
The rl4106 is powered by a single 3.6VAA Lithium battery, which can be fittedby the user. The battery life will bedependent on the transmission rate set.An indicator on the LCD will warn when
the battery is low, and the rl4106maintains a record of when the batterywas last changed.
The moulded case allows easy accessto the battery and USB socket, as wellas having slots to fit onto secure wallbrackets and a plain front panel to hidethe LCD if more discreet monitoring ofpublic areas is desired.
The rl4000 range has been designed tocomply with the RoHS and WEEE EUdirectives, and carries the CE mark.
Product Code RL4106Series rl4000
Typical ApplicationsMonitoring in: ° Hospitals° Pharmaceutical° Warehousing
InstrumentDimensions: 110 x 80 x 35mmWeight: 200 gramsPower Supply: 3.6 Volt AA Lithium batteryBattery Life: 18 monthsCase Materials: ABS & PCOperatingHumidity Range: 0 to 100% non-condensingOperating Temp Range: -15° to +65° CMemory Capacity: 100000 readings
Sensors TemperatureSensor: Precision thermistorRange: -15° to +65° CAccuracy: +/- 0.2° C between
-15° C to +65° CResolution: 0.1° C
HumiditySensor: Capacitive polymerRange: 0 to 100% non-condensingAccuracy: +/- 0.2° C Resolution: 0.1° C
Radio*Radio Frequency: 434.075MHz
433.920MHz (fixed)433.875 - 434.650MHz in 25KHz increments(synthesised)
Radio Power: 10 mWRadio Range: 3 km over open ground
AccessoriesCode:
Y119 Wall mounting security bracketY055 Setup communications cableG129 Replacement 3.6V Lithium AA
battery
Temperature & humidity
Radiologger - Transmitter
Above:Detail of USB socket
Below:Optional wall mountingsecurity bracket
ISI sa-nv - Instrumentation for Science and Industry (INTERCONTINENTAL SERVICES INC)Rue du Doyenné 3 Dekenijstraat 1180 Brussels – Belgium - Tel 02/ 343 30 81 Fax 343 12 05 mail : [email protected] web : www.isi-be.com
Instrumentation for Science and IndustryInstrumentation for Science and IndustryInstrumentation for Science and IndustryInstrumentation for Science and Industry ISI sa-nv Rue du Doyenné 3 - 1180 Brussels Tel +32 (0) 2 343 30 81 Fax 02/ 343 12 05 web : http:// www.isi-be.com mail : [email protected]
Technical SummaryInstrumentDimensions: 100 x 100 x 60 mm
Weight: 600g
Power Supply: User replaceable 2 x alkaline ‘D’ cell Battery pack.
Battery Life: Up to five years (Based on one message a day i.e.
30 minute pulse count and no events enabled)
Case Material: ABS & PC
N.B Instrument operating range -20oe -20e -20 C to 60oo 60o 60 C in a
non-condensing RH environment
GPRS – Quad band moduleNetwork Compatibility: Quad band, band user selectable
(Quad Band) Aerial Connection: SMA socket
Aerial Type: Stubby straight/right angle + optional remote mount on 2mtrs cable
iSense GPRS TransmitteriS
EN
SE
G
PR
S T
RA
NS
MIT
TE
R
Features:
Completely self contained (battery operated)
Date and time stamped monitoring
Up to five year battery life
Transmit rate increase on event
Remote setup options
Data stored in non volatile memory
All data recovered in the event of temporary GPRS coverage problems
Easy to understand journey profile information
Works with a range of sensor families
Evolved from Hanwells existing range of established
radio logging products the iSense is an innovative
self contained unit enabling remote monitoring of
diverse parameters via wireless GPRS technology.
Locations that previously seemed inaccessible
including, buildings, machinery, infrastructure or
vehicles can now easily be accessed and monitored.
A number of different sensors can be attached to
the iSense in order to monitor parameters such as
energy, temperature, pressure, structural stress and
many more.
This real-time information is then transmitted via
GPRS to a central database, and can be accessed
immediately on a PC for viewing, recording and
assessment.
Product benefitsGPRS technology
Non-Intrusive design
Easy installation
A wide range of monitoring
parameters available
Individual configuration options
Easy reading management system
Comprehensive analysis and
data history
Up to five year battery life
Instrumentation for Science and IndustryInstrumentation for Science and IndustryInstrumentation for Science and IndustryInstrumentation for Science and Industry ISI sa-nv Rue du Doyenné 3 - 1180 Brussels Tel +32 (0) 2 343 30 81 Fax 02/ 343 12 05 web : http:// www.isi-be.com mail : [email protected]
Server
SR2 User PC
GPRS – IP Addresssecure access via DMZ
(demilitarised zone)
Network
Application: Oil tankPressure and level
Application: HospitalFridges and freezer monitoring
Application: TruckTemperature
Application: BridgeShock and vib ration
Application: SchoolEnergy monitoring
hanwell.com
iSense communication to your local PC is easy
using GPRS technology
Typical applications
Bridge stress and vibration monitoring
Schools energy monitoring
Hospitals and hospital food
transportation monitoring
Fridge temperature monitoring
Civil engineering
Laboratory monitoring
Chemical transportation
Instrumentation for Science and IndustryInstrumentation for Science and IndustryInstrumentation for Science and IndustryInstrumentation for Science and Industry ISI sa-nv Rue du Doyenné 3 - 1180 Brussels Tel +32 (0) 2 343 30 81 Fax 02/ 343 12 05 web : http:// www.isi-be.com mail : [email protected]
iS
EN
SE
G
PR
S T
RA
NS
MIT
TE
R
Easy installation of software
Clear set up capabilities
Easily integrated into existing Hanwell
monitoring system
Uncomplicated set-up capabilities
Immediate access to graphical data
Date and time specific
Clear visual and statistical evidence of iSense environmental conditions
Straightforward data retrieval
These screen shots show typical results for an
iSense transmitting data for temperature and
humidity (above) and energy (right).
The screen shot opposite is an example of the set-up capabilities
available to the user.
Instrumentation for Science and IndustryInstrumentation for Science and IndustryInstrumentation for Science and IndustryInstrumentation for Science and Industry ISI sa-nv Rue du Doyenné 3 - 1180 Brussels Tel +32 (0) 2 343 30 81 Fax 02/ 343 12 05 web : http:// www.isi-be.com mail : [email protected]
The part numbers for the iSense product range are constructed in four parts as follows:
Where
C1 = code for sensor on channel 1
C2 = code for sensor on channel 2 (00 = channel not used)
C3 = code for sensor on channel 3 (00 = channel not used)
PS = power supply option
Currently available channel options include:
Temperature
Humidity
Voltage
Current
Pulse Counting
Not all combinations are possible, please check with factory before ordering.
For parameters not listed, please contact our sales team on +44 (0)1462 688070
or email [email protected].
For further information and a full list of part numbers, visit www.hanwell.com/isense-spec
Each iSense unit requires a valid sim card contract and adequate network coverage at the
intended location.
iS
EN
SE
G
PR
S T
RA
NS
MIT
TE
R
IS – iSense Basic Module
Never compromising on craftsmanship, we have enhanced our products and services
through design and manufacture, with all units being produced at our facility within the UK.
We pride ourselves in our ability to accurately interpret customer requirements. If you
require the monitoring of any substance or element not mentioned in this brochure, please hure, please hure, please
call as we will, almost certainly, have a solution for you.
C1 C2 C3 PSIS:
Instrumentation for Science and IndustryInstrumentation for Science and IndustryInstrumentation for Science and IndustryInstrumentation for Science and Industry ISI sa-nv Rue du Doyenné 3 - 1180 Brussels Tel +32 (0) 2 343 30 81 Fax 02/ 343 12 05 web : http:// www.isi-be.com mail : [email protected]
Instrumentation for Science and IndustryRue du Doyenné, 31180 - BrusselsBelgium
T: +32 (2)343 30 81
W: www.isi-be.com
Contact
CO
NT
AC
T
Instrumentation for Science and IndustryInstrumentation for Science and IndustryInstrumentation for Science and IndustryInstrumentation for Science and Industry ISI sa-nv Rue du Doyenné 3 - 1180 Brussels Tel +32 (0) 2 343 30 81 Fax 02/ 343 12 05 web : http:// www.isi-be.com mail : [email protected]