2
Meas. = Reading Off Main Scale + Vernier The Vernier Scale is read at the point where the Vernier graduations align with the Main Scale graduations. 0 50 100 90 80 70 60 40 30 20 10 mm 0 10 20 30 40 50 60 70 80 90 0 0.05mm 0 10 20 30 0 0 .10 .20 .30 .40 .50 .60 .70 .80 .90 40 50 60 70 80 90 100 0 50 70 60 40 30 20 10 0 10 20 30 40 50 60 70 80 90 0 0.05mm 40 30 20 0 10 20 30 Calipers are the most versatile measuring tool in the shop, able to measure outside dimensions, inside dimensions, depth, and step height. 100 90 80 70 100 90 80 70 0 10 20 30 40 50 60 70 80 90 0 0 10 20 30 40 50 60 70 80 90 0 MEASURING TOOLS BOOK Model No. SB-NM1025 VERNIER CALIPER GVC-10 AND MICROMETER MC105-25 COMBINATION SET INSTRUCTION MANUAL I396-K 1909 ノギス Lock Screw Inside Jaws Beam Thumb Grip Slide Vernier Scale Outside Jaws Main Scale Inside Step Depth Outside 1. Loosen Lock Screw 2. Lightly gasp the Beam 4. Adjust the Slide 3. Place thumb on Grip How to Hold The measurement using both the Main Scale and the Vernier Scale. Below there are examples reading 77.00mm measurement in the first example, and 77.35mm. for the second example. Measure- ment = 77.00mm Ex.1 Measure- ment = 77.35mm Ex.2 77 0.35 77.35 Reading 77 0.00 77.00 Reading Main Scale (1㎜) Vernier (0.05㎜) Main Scale (1㎜) Vernier (0.05㎜) Reading the Scale 3 Positioning on Workpiece Viewing the Scale (Measurement shown in figure is 28.05mm) Graduations Align Here ●For Flat Parts Jaws should be perpen- dicular to the surface. ●For Cylindrical Parts Jaws should be at right angle to the axis of the cylinder. Read the Scale from directly above the Calipers. If the Scale is viewed at an angle, the difference in height between the Main Scale and the Vernier Scale may cause measurement error due to parallax. Jaws at 90° OUTSIDE MICROMETER ◇ ModelMC105-25 Meas. Range025mm ◇ Graduations0.01mm Instrument Error4µm ◇ AccessoriesSpanner SAFETY NOTES Please read and follow these instructions. Improper use may lead to accidents, injuries, product damage, or inaccurate measurements. Use only for measuring. Handle with care - do not drop or shock, and do not place under heavy objects. Do not damage gauge, such as by engraving name or number on it. Keep away from rain, high humidity, temperature extremes, and direct sunlight during use and storage. Do not disassemble or modify. Use caution when handling Caliper - Jaw tips are sharp. Always make sure Lock Screw is loose before moving Caliper Slide. SET INCLUDES VERNIER CALIPERS ◇ ModelGVC-10 Max Meas. Length100mm ◇ Graduations0.05mm ◇ Accuracy±0.05mm Depth Bar Niigata Seiki Co., Ltd. 5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055 Tel. : +81-256-33-5522 Fax. : +81-256-33-5518 MAIL [email protected] URL http://www.niigataseiki.co.jp CALIPERS

Model No. MEASURING OUTSIDE MICROMETER

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Meas. = Reading Off Main Scale + VernierThe Vernier Scale is read at the point where the Vernier graduations align with the Main Scale graduations.

0 50 1009080706040302010 mm

0 10 20 30 40 50 60 70 80 90 00.05mm

010

2030

0

0

.10 .20 .30 .40 .50 .60 .70 .80 .90

4050

6070

8090

100

0 50 80706040302010

0 10 20 30 40 50 60 70 80 90 00.05mm

0 50 1009080706040302010

0 10 20 30 40 50 60 70 80 90 00.05mm

Calipers are the most versatile measuring tool in the shop, able to measure outside dimensions, inside dimensions, depth, and step height.

100908070

100908070

0 10 20 30 40 50 60 70 80 90 0

0 10 20 30 40 50 60 70 80 90 0

MEASURINGTOOLS BOOK

Model No. SB-NM1025

VERNIER CALIPER GVC-10 AND MICROMETER MC105-25COMBINATION SET

INSTRUCTION MANUAL

I396-K 1909ノギス

Lock Screw

Inside Jaws

Beam

Thumb GripSlide

Vernier Scale

Outside Jaws

Main Scale

2 Inside 3 Step

4 Depth

1 Outside

1. LoosenLock Screw

2. Lightlygasp the

Beam

4. Adjust theSlide

3. Place thumb on Grip

How to Hold

The measurement using both the Main Scale and the Vernier Scale. Below there are examples reading 77.00mm measurement in the first example, and 77.35mm. for the second example.

Measure-ment =

77.00mm

Ex.1

Measure-ment =

77.35mm

Ex.277

0.35+77.35

Reading

770.00+

77.00

ReadingMain Scale(1㎜)Vernier

(0.05㎜)

Main Scale(1㎜)Vernier

(0.05㎜)

Reading the Scale3Positioning on Workpiece1

Viewing the Scale2

(Measurement shown in figure is 28.05mm)Graduations Align Here

●For Flat PartsJaws should be perpen-dicular to the surface.

●For Cylindrical PartsJaws should be at rightangle to the axis of thecylinder.

Read the Scale from directly above the Calipers. If the Scale is viewed at an angle, the difference in height between the Main Scale and the Vernier Scale may cause measurement error due to parallax.

Jawsat 90°

OUTSIDE MICROMETER◇ Model:MC105-25◇ Meas. Range:0~25mm◇ Graduations:0.01mm◇ Instrument Error:4µm◇ Accessories:Spanner

SAFETY NOTES●Please read and follow these instructions. Improper use may lead toaccidents, injuries, product damage, or inaccurate measurements.●Use only for measuring. ●Handle with care - do not drop or shock, anddo not place under heavy objects. ●Do not damage gauge, such as byengraving name or number on it. ●Keep away from rain, high humidity,temperature extremes, and direct sunlight during use and storage.●Do not disassemble or modify. ●Use caution when handling Caliper -Jaw tips are sharp. ●Always make sure Lock Screw is loose beforemoving Caliper Slide.

◎ SET INCLUDESVERNIER CALIPERS

◇ Model:GVC-10◇ Max Meas. Length:100mm◇ Graduations:0.05mm◇ Accuracy:±0.05mm

Depth Bar

Niigata Seiki Co., Ltd.5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055Tel. : +81-256-33-5522 Fax. : +81-256-33-5518MAIL [email protected] http://www.niigataseiki.co.jp

CALIPERS

Micrometers use a threaded Spindle to measure length for more accuracy than measurements made with Calipers.

Center of scale becomes move visible!

Stepped Scale makes 1mm units easy to distinguish at a glance!

Sleeve

ThimbleSpindleAnvil (Fixed Side)

Spindle Lock

Ratchet Stop

Thermal Shield

Grip the Micrometer on the Thermal Shield to prevent thermal expansion from body heat, and use the Ratchet Stop for consistent meas. force.

Thermal Shield

Ratchet StopPart

Measured here

Frame

Setting the 0-Point1 Reading the Scale2

Spanner

(Rear)

⑦ Check Accuracy

⑥ Check Accuracy(Mounting on Micrometer Stand)

30

35

40

45

30

35

40

45

30

35

40

45

The Sleeve reading is 7.5mm, and the Thimble reading adds 0.37mm, for a total measurement of 7.87mm.

Sleeve Reading:7 .Thimble Reading: .37

Measurement:7 .37(mm)

Sleeve Thimble Sleeve Thimble

Sleeve Line Thimble

【~+1μm】 【~+2μm】

Sleeve Line Thimble

0.5mm Scale

1mm Scale

0 50 5

●Reading Example① Clean the Measurement SurfacesTo clean both the Anvil and Spindle measurement surfaces, place a clean sheet of paper between them and lightly close the Micrometer. Pull the paper across the surfaces to clean. Open the Micrometer to remove the paper.※Paper may produce dust at the edges, so do not pull

all the way out, but open the Micrometer to remove.

※ Setting the 0-Point is not sufficient to insure accurate measurements. This procedure will check for errors in the pitch of the SpindleThreads caused by wear.

② Close using Ratchet StopThe amount of force used to turn the Spindle is critical. Turn the Ratchet Stop until the Measurement Surfaces touch and the ratchet clicks 1 to 3 times.

③ Set the ClampIn the photo to the left, the 0-Point is off by about 5 μm, so it is necessary to adjust. First, tighten the Spindle Clamp using the Lever to hold the Spindle in position.

④ Insert the SpannerTo adjust the 0-Point, insert the Spanner into the hole in the sleeve and rotate. Make sure the Spanner is firmly pushed into hole, or it will slip and scratch the scale. Please use care.

⑤ Align the Scale to 0Here the Scale is aligned to read 0. Always read the Scale from directly above, reading at an angle can cause a 2 ~ 3μm reading error.

Place the Micrometer into a Stand.

(Using Block Gauge)

Place a Block Gage in the Micrometer and measure. The measurement should match the dimension on the Gauge. This will confirm the overall accuracy of the instrument.

~5μm Off

oClamp

※ You can read down to0.01mm using the abovemethod, but you canalso read down to0.001mm (1 μm) asshown in this diagram.

On the Sleeve, the lower scale is 1mm increments, andthe upper scale is also 1mm increments, but half waybetween, so for the two scales there is a line every 0.5mm.While the Scale is very easy to read, care must betaken not to misread the last line, especially on the0.5mm Scale, since if the line is not seen or isneglected the measurement will be off by 0.5mm.

CALIBRATION

The New Shape in Measurement

Introducing KAIDAN SeriesNew stepped scale makes for error free 1mm reading at a glance!

Instruments should be calibrated regularly to insure accuracy. Wear and repeated use can affect accuracy. We recommend periodic calibration.

MICRO-METER

Measuring Surfaces(Carbide)

How to Hold

Sleeve Reading:7 .5Thimble Reading: .37

Measurement:7 .87(mm)

The Sleeve reading is 7.mm, andthe Thimble reading adds 0.37mm,for a total measurement of 7.37mm.

KAIDAN

KAIDAN

KAIDAN, meaning steps in Japanese, makes the scale graduations more visible.Improves accuracy of reading and the reading speed of measurements.