219
LIBRARY-1 ASAQS Standard Library-Common Trades (July 99 Ammendments) DESCRIPTION UNIT QUANTITY BILL ? EARTHWORKS (PROVISIONAL) SUPPLEMENTARY PREAMBLES Nature of ground Use "assumed to be" if no trial holes, soils investigations, etc have been carried out - discuss with engineer. Use "Trial holes indicate that" where the ground has been investigated by means of trial holes Nature of ground A soils investigation has been carried out on site by the engineer and the report is annexed to these bills of quantities. Descriptions of excavations shall be deemed to include all ground conditions classifiable as "earth" described in the above report and where conditions of a more difficult character are indicated these are separately measured Carting away of excavated material Descriptions of carting away of excavated material shall be deemed to include loading excavated material onto trucks directly from the excavations or, alternatively, from stock piles situated on the building site DEMOLITIONS ETC Breaking up and removing ? Thick concrete surface beds, paving, etc m2 ? Thick mesh reinforced concrete surface beds, paving, etc m2 ? Thick brick paving with mortar joints m2 ? x ? Concrete kerbs m ? x ? Brick kerbs with mortar joints m Taking down and removing Diamond mesh fence ?m high with steel posts and droppers m ? Fence ?m high with ? posts and ? droppers m

Model Bill

Embed Size (px)

Citation preview

Page 1: Model Bill

LIBRARY-1ASAQS Standard Library-Common Trades (July 99 Ammendments)DESCRIPTION UNIT QUANTITYBILL ?

EARTHWORKS (PROVISIONAL)

SUPPLEMENTARY PREAMBLES

Nature of ground

Use "assumed to be" if no trial holes, soils investigations, etc have been carried out - discuss with engineer. Use "Trial holes indicate that" where the ground has been investigated by means of trial holes

Nature of ground

A soils investigation has been carried out on site by the engineer and the report is annexed to these bills of quantities. Descriptions of excavations shall be deemed to include all ground conditions classifiable as "earth" described in the above report and where conditions of a more difficult character are indicated these are separately measured

Carting away of excavated material

Descriptions of carting away of excavated material shall be deemed to include loading excavated material onto trucks directly from the excavations or, alternatively, from stock piles situated on the building site

DEMOLITIONS ETC

Breaking up and removing

? Thick concrete surface beds, paving, etc m2

? Thick mesh reinforced concrete surface beds, paving, etc m2

? Thick brick paving with mortar joints m2

? x ? Concrete kerbs m

? x ? Brick kerbs with mortar joints m

Taking down and removing

Diamond mesh fence ?m high with steel posts and droppers m

? Fence ?m high with ? posts and ? droppers m

? Security fence with 45 degree barbed wire overhang ?m high m overall with ? posts and ? droppers

Page 2: Model Bill

Half brick boundary or yard wall ?m high m

Demolishing and removing

Single storey building with pitched roof ? x ?m on plan and ?m high No at eaves comprising concrete surface bed, ? external walls, ? internal walls and ? roof covering on ? trusses

? storey building with flat roof ? x ?m on plan and ?m high overall No comprising concrete surface bed, reinforced concrete intermediate and roof slabs, ? external walls and ? internal walls

SITE CLEARANCE ETC

User Note:

Where the value is of significance, the removal of hedges etc shall be given separately in meters or in number

Site clearance

Digging up and removing rubbish, debris, vegetation, hedges, shrubs m2 and trees not exceeding 200mm girth, bush, etc

Stripping average ?mm thick layer of top soil and stockpiling on site m2

REMOVAL OF TREES ETC

Taking out and removing, grubbing up roots and filling in holes

Tree stump exceeding 200mm and not exceeding 500mm girth No

Tree stump exceeding ?mm and not exceeding ?mm girth No

Cutting down and removing, grubbing up roots and filling in holes

Hedge not exceeding ?mm high m

Hedge exceeding ?mm and not exceeding ?mm high m

Tree exceeding 200mm and not exceeding 500mm girth No

Tree exceeding ?mm and not exceeding ?mm girth No

BULK EXCAVATION, FILLING, ETC

User Note:

This section is given as an alternative option and in the event of it being exercised the excavation, filling, etc other than bulk is to be given under the later section

Open face excavation in earth over sloping site

Page 3: Model Bill

Open face excavation m3

Excavation in earth for basement

Not exceeding 2m deep m3

Exceeding 2m and not exceeding 4m deep m3

Exceeding 4m and not exceeding 6m deep m3

Exceeding ?m and not exceeding ?m deep m3

Excavation in earth within basement (basement level exceeding ?m and not exceeding ?m deep below ground level)

Not exceeding 2m deep to reduce levels to final levels under floors m3 etc

To remove sloping banks m3

To remove sloping banks in ?m alternating sections m3

Back excavation of vertical sides of excavation in earth for working space including backfilling compacted to ? % Mod AASHTO density

Not exceeding 500mm deep for placing and removing formwork to m3 walls etc ?mm away from excavated face

Exceeding ?m and not exceeding ?m deep for placing and removing m2 formwork to walls etc ?mm away from excavated face

Not exceeding 500mm deep for placing and removing formwork to m2 walls etc and building brick lining ?mm away from excavated face

Exceeding ?m and not exceeding ?m deep for placing and removing m2 formwork to walls etc and building brick lining ?mm away from excavated face

Not exceeding 500mm deep for placing and removing formwork to m2 walls etc against excavated face

Exceeding ?m and not exceeding ?m deep for placing and removing m2 formwork to walls etc against excavated face

Extra over bulk excavation in earth for excavation in

Soft rock m3

Hard rock m3

Extra over bulk excavation in earth for breaking up and removing

Page 4: Model Bill

Brickwork m3

Unreinforced concrete m3

Reinforced concrete m3

Extra over back excavation in earth for working space for excavation in soft rock

Extra over back excavation in earth for working space for excavation in hard rock

Not exceeding 500mm deep for placing and removing formwork to m2 walls etc ?mm away from excavated face

Exceeding ?m and not exceeding ?m deep for placing and removing m2 formwork to walls etc ?mm away from excavated face

Not exceeding 500mm deep for placing and removing formwork to m2 walls etc and building brick lining ?mm away from excavated face

Exceeding ?m and not exceeding ?m deep for placing and removing m2 formwork to walls etc and building brick lining ?mm away from excavated face

Not exceeding 500mm deep for placing and removing formwork to m2 walls etc against excavated face

Exceeding ?m and not exceeding ?m deep for placing and removing m2 formwork to walls etc against excavated face

Extra over all excavations for carting away

Surplus material from excavations and/or stock piles on site to a m3 dumping site to be located by the contractor

Surplus material from excavations and/or stock piles on site to a m3 dumping site situated approximately ?km from the building site

Risk of collapse of excavations

Sides of bulk excavations not exceeding 1,5m deep m2

Sides of bulk excavations exceeding 1,5m deep m2

Keeping excavations free of water

Keeping excavations free of all water other than subterranean water Item

Earth filling obtained from the excavations (not compacted)

Page 5: Model Bill

Earth filling obtained from the excavations including haulage approximately ?m from perimeter of excavations (not compacted)

In prescribed stock piles on site m3

Earth filling obtained from the excavations and/or prescribed stock piles on site (not compacted)

Earth filling obtained from the excavations and/or prescribed stock piles on site compacted to ?% Mod AASHTO density

Earth filling obtained from the excavations and/or prescribed stock piles on site including haulage approximately ?m from perimeter of excavations or stock piles compacted to ?% Mod AASHTO density

Earth filling supplied by the contractor compacted to ?% Mod AASHTO density

Over site m3

Over site to form platforms m3

Compaction of surfaces

Compaction of ground surface under ? etc by wetting and compacting m3 with ? passes of a ? ton vibratory roller

Compaction of ground surface under floors etc including scarifying m2 for a depth of ?mm, breaking down oversize material, adding suitable material where necessary and compacting to ?% Mod AASHTO density

Prescribed density tests on filling

Natural California Bearing Ratio test No

Road Indicator test No

Field Density test including "Optimum Moisture Content" (four kg readings per test)

EXCAVATION, FILLING, ETC

EXCAVATION, FILLING, ETC OTHER THAN BULK

Open face excavation in earth over sloping site

Open face excavation m3

Excavation in earth not exceeding 2m deep

Excavation in earth exceeding 2m and not exceeding 4m deep

Page 6: Model Bill

Excavation in earth exceeding ?m and not exceeding ?m deep

Basement m3

Lift pit m3

Swimming Pool m3

Reduced levels under floors m3

Trenches m3

Holes m3

Holes including working around piles m3

Trenches and holes for thickening under surface beds etc m3

Underpinning in ?m alternating sections under existing foundations m3

Excavation in earth not exceeding 2m deep below reduced level (reduced level exceeding ?m and not exceeding ?m below ground level)

Excavation in earth exceeding ?m and not exceeding ?m deep below reduced level (reduced level exceeding ?m and not exceeding ?m below ground level)

Excavation in earth not exceeding 2m deep within basement (basement level exceeding ?m and not exceeding ?m deep below ground level)

Excavation in earth exceeding ?m and not exceeding ?m deep within basement (basement level exceeding ?m and not exceeding ?m deep below ground level)

To reduce levels to final levels under floors etc m3

To remove sloping banks m3

To remove sloping banks in ?m alternating sections m3

Lift pit m3

Trenches m3

Holes m3

Holes including working around piles m3

Trenches and holes for thickening under surface beds etc m3

Underpinning in ?m alternating sections under existing foundations m3

Page 7: Model Bill

Back excavation of vertical sides of excavation in earth for working space including backfilling compacted to ?% Mod AASHTO density

Not exceeding 500mm deep for placing and removing formwork to m2 walls etc ?mm away from excavated face

Exceeding ?m and not exceeding ?m deep for placing and removing m2 formwork to walls etc ?mm away from excavated face

Not exceeding 500m deep for placing and removing formwork to m2 walls etc and building brick lining ?mm away from excavated face

Exceeding ?m and not exceeding ?m deep for placing and removing m2 formwork to walls etc and building brick lining ?mm away from excavated face

Not exceeding 500mm deep for placing and removing formwork to m2 walls etc against excavated face

Exceeding ?m and not exceeding ?m deep for placing and removing m2 formwork to walls etc against excavated face

Extra over bulk excavation in earth for excavation in

Soft rock m3

Hard rock m3

Extra over bulk excavation in earth for breaking up and removing

Brickwork m3

Unreinforced concrete m3

Reinforced concrete m3

Extra over trench and hole excavations in earth for excavation in

Soft rock m3

Hard rock m3

Extra over trench and hole excavations in earth for breaking up and removing

Brickwork m3

Unreinforced concrete m3

Reinforced concrete m3

Page 8: Model Bill

Extra over back excavation in earth for working space for excavation in soft rock

Extra over back excavation in earth for working space for excavation in hard rock

Not exceeding 500mm deep for placing and removing formwork to m2 walls etc ?mm away from excavated face

Exceeding ?m and not exceeding ?m deep for placing and removing m2 formwork to walls etc ? mm away from excavated face

Not exceeding 500m deep for placing and removing formwork to m2 walls etc and building brick lining ?mm away from excavated face

Exceeding ?m and not exceeding ?m deep for placing and removing m2 formwork to walls etc and building brick lining ?mm away from excavated face

Not exceeding 500mm deep for placing and removing formwork to m2 walls etc against excavated face

Exceeding ?m and not exceeding ?m deep for placing and removing m2 formwork to walls etc against excavated face

Extra over all excavations for carting away

Surplus material from excavations and/or stock piles on site to a m3 dumping site to be located by the contractor

Surplus material from excavations and/or stock piles on site to a m3 dumping site situated approximately ?km from the building site

Risk of collapse of excavations

Sides of bulk excavations not exceeding 1,5m deep m2

Sides of bulk excavations exceeding 1,5m deep m2

Sides of trench and hole excavations not exceeding 1,5m deep m2

Sides of trench and hole excavations exceeding 1,5m deep m2

Keeping excavations free of water

Keeping excavations free of all water other than subterranean water Item

Earth filling obtained from the excavations (not compacted)

Earth filling obtained from the excavations including haulage approximately ?m from perimeter of excavations (not compacted)

Page 9: Model Bill

In prescribed stock piles on site m3

Earth filling obtained from the excavations and/or prescribed stock piles on site (not compacted)

Earth filling obtained from the excavations and/or prescribed stock piles on site including haulage approximately ?m from perimeter of excavations or stock piles (not compacted)

Earth filling supplied by the contractor (not compacted)

Earth filling obtained from the excavations and/or prescribed stock piles on site compacted to ?% Mod AASHTO density

Earth filling obtained from the excavations and/or prescribed stock piles on site including haulage approximately ?m from perimeter of excavations or stock piles compacted to ?% Mod AASHTO density

Earth filling supplied by the contractor compacted to ?% Mod AASHTO density

Over site m3

Landscape mounds, berms, etc m3

Under floors, steps, pavings, etc m3

Backfilling behind retaining walls m3

Backfilling to trenches, holes, etc m3

Garden soil filling obtained from the excavations and/or prescribed stock piles on site

Garden soil filling obtained from the excavations and/or prescribed stock piles on site including haulage approximately ?m from perimeter of excavations or stock piles

Garden soil filling supplied by the contractor

In flower boxes m3

Over site m3

To landscape mounds, berms, etc m3

Coarse river sand filling supplied by the contractor

Under floors etc m3

Behind retaining walls m3

Page 10: Model Bill

In floor ducts m3

Hardcore filling

Under floors etc m3

Stone filling of 19mm broken stone

Under floors etc m3

Behind retaining walls m3

In flower boxes m3

Compaction of surfaces

Compaction of ground surface under floors etc by wetting and m2 compacting with ? passes of a ? ton vibratory roller

Compaction of ground surface under floors etc including scarifying m2 for a depth of ?mm, breaking down oversize material, adding suitable material where necessary and compacting to ?% Mod AASHTO density

Prescribed density tests on filling

Modified AASHTO Density test No

Natural California Bearing Ratio test No

Road Indicator test No

Field Density test including "Optimum Moisture Content" (four kg readings per test)

STONE PITCHING

Stone pitching of approximately ?mm diameter river stones tightly packed including preparation of ground surface under

?mm Thick against sloping banks m2

?mm Thick against sloping banks bedded and jointed in 1:8 cement m2 mortar and pointed with hollow recessed joints

GRASSING

Grassing of roots in rows

Grassing of rolls approximately ?mm thick

Grassing of sods approximately ? x ? x ?mm thick

Kikuyu grass over site m2

Page 11: Model Bill

? grass over site m2

? grass on sports fields m2

Fertilizing

Fertilizing garden soil with ? % ? mixture spread at a rate of ?kg/m2 m2 and ? fertilizer spread at a rate of ? kg/m2 including working evenly into top ?mm depth of soil

Fertilizing grassed areas with ? fertilizer at a rate of ? kg/m2 after m2 completion of planting

Maintenance

Maintenance of grassed areas for a period of ? months (total area Item approximately ? m2) including regularly weeding and irrigating as necessary

GABIONS AND INTERLOCKING BLOCK RETAINING STRUCTURES

Gabions of ? galvanised wire boxes laced together and filled with broken stone

?mm Thick retaining wall of ? x ? x ?mm boxes properly bonded m3

Embankment protection ?mm thick of ? x ? x ?mm mattresses with m3 diaphragm divisions at ?mm centres butt jointed

Loffelstein precast concrete interlocking planter blocks finished smooth on exposed surfaces

? precast concrete interlocking planter blocks finished smooth on exposed surfaces

User note: "Loffelstein" planter blocks are available in various sizes and in "standard" and "heavy duty" in each size. Type is dependent mainly of wall and soil conditions

Retaining structure with stepped face and curves as required to suit m2 slopes of 500 x 450 x 170mm high type L300 interlocking planter blocks laid horizontal bed joints to ? degree slope including backfilling with earth obtained from the excavations and filling the blocks with garden soil lightly tamped as the work proceeds

Retaining structure with stepped face and curves as required to suit m2 slopes of ? x ? x ?mm high type "?" interlocking planter blocks laid with horizontal bed joints to ? degree slope including backfilling with

Page 12: Model Bill

earth obtained from excavations and filling the blocks with garden soil lightly tamped as the work proceeds

Terraforce precast concrete interlocking planter blocks

Retaining structure with stepped face and curves as required to suit m2 slopes of ? x ? x ?mm high type "?" interlocking planter blocks laid with horizontal bed joints to ? degree slope including backfilling with earth obtained from the excavations and filling the blocks with garden soil lightly tamped as the work proceeds

Retaining structure with stepped face and curves as required to suit m2 slopes of ? x ? x ?mm high type "?" interlocking planter blocks laid with horizontal bed joints to ? degree slope including backfilling with earth obtained from the excavations and filling the blocks with garden soil lightly tamped as the work proceeds

FILTER FABRIC

? x ? filter fabric with ?mm laps

Non-woven continuous filament needle punch polyester filter fabric weighing not less than ? kg/m2 with ?mm laps

Under stone filled gabions including preparing ground surface under m2

Vertically behind stone filled gabion retaining walls m2

Over stone percolation beds in flower boxes m2

Around stone filling in sub-soil drain trenches m2

SOIL POISONING

? Weedkiller mixed in the proportion of ? weedkiller to ? water and applied at a rate of ?/m2

Under paving etc m2

Soil insecticide

Under floors etc including forming and poisoning shallow furrows m2 against foundation walls etc, filling in furrows and ramming

To bottoms and sides of trenches etc m2

BILL ?

Page 13: Model Bill

CONCRETE, FORMWORK AND REINFORCEMENT

SUPPLEMENTARY PREAMBLES

Cost of tests

The costs of making, storing and testing of concrete test cubes as required under clause 7 "Tests" of SABS 1200 G shall include the cost of providing cube moulds necessary for the purpose, for testing costs and for submitting reports on the tests to the architect. The testing shall be undertaken by an independent firm or institution nominated by the contractor to the approval of the architect. (Test cubes are measured separately)

Breeze concrete shall consist of twelve parts clean dry furnace ash, free from coal or other foreign matter, to one part cement (12:1), the ash graded up to particles which will pass a 16,5mm ring from a minimum which fails to pass a 4,75mm mesh. The finer materials from the screening are to be first mixed with the cement into a mortar and the ash added afterwards and thoroughly incorporated

Foamcement lightwieght concrete

Foamcement lightweight concrete is to have a density of 600kg/m3 for the top 50mm and 400kg/m3 for the remaining thickness. The minimum thickness at outlets, channels, etc shall be 50mm

Celbeton lightweight concrete

Celbeton lightweight concrete is to have a density of 1000kg/m3 for the top 20mm and 480kg/m3 for the remaining thickness. The minimum thickness at outlets, channels, etc shall be 30mm

Formwork

Description of formwork shall be deemed to include use and waste only (except where described as "left in" or "permanent"), for fitting together in the required forms, wedging, plumbing and fixing to true angles and surfaces as necessary to ensure easy release during stripping and for reconditioning as necessary before re-use

The vertical strutting shall be carried down to such construction as is sufficiently strong to afford the required support without damage and shall remain in position until the newly constructed work is able to support itself.

Formworks to soffits of solid etc shall be deemed to be slabs not exceeding 250mm thick unless otherwise described

Page 14: Model Bill

Formwork to sides of bases, pile caps, ground beams, etc will only be measured where it is prescribed by the engineer for design reasons. Formwork necessitated by irregularity or collapse of excavated faces will not be measured and the cost thereof shall be deemed to be included in the allowance for taking the risk of collapse of the sides of the excavations, provision for which is made in "Earthworks"

LIGHTWEIGHT CONCRETE

Breeze concrete

Grading to slabs m3

Finishing smooth top surfaces of grading to falls for waterproofing m2 including 1:8 monolithic cement plaster screed as necessary

Finishing smooth top surfaces of grading to falls and currents for m2 waterproofing including 1:8 monolithic cement plaster screed as necessary

? x ?mm 1:8 Cement plaster triangular fillet against walls etc m

? lightweight concrete

Grading to slabs m3

Finishing smooth top surfaces of grading to falls for waterproofing m2

Finishing smooth top surfaces of grading to falls and currents for m2 waterproofing

? x ?mm Triangular fillet against walls etc m

UNREINFORCED CONCRETE

UNREINFORCED CONCRETE CAST AGAINST EXCAVATED SURFACES

No fines concrete

Class ? concrete

?MPa/?mm concrete

Surface blinding under surface beds m3

Surface blinding under footings and bases m3

Strip footings m3

Page 15: Model Bill

Surface beds m3

Surface beds on waterproofing m3

Surface beds cast in panels m3

Surface beds cast in panels on waterproofing m3

Pavings m3

Pavings cast in panels m3

Ramps m3

Bottoms and sides of floor ducts m3

Machine bases m3

Steps, urinal steps, cupboard platforms, etc m3

REINFORCED CONCRETE

REINFORCED CONCRETE CAST AGAINST EXCAVATED SURFACES

?MPa/?mm concrete

Strip footings m3

Bases m3

Pile caps m3

Foundation beams m3

Surface beds m3

Surface beds on waterproofing m3

Surface beds cast in panels m3

Surface beds cast in panels on waterproofing m3

Pavings m3

Bottoms and sides of floor ducts m3

Slabs including beams and inverted beams m3

Stepped slabs including beams and inverted beams m3

Coffered slabs including beams and inverted beams m3

Troughed slabs including beams and inverted beams m3

Page 16: Model Bill

Composite hollow block slabs including beams and inverted beams m3

Composite prefabricated beam and trough slabs including beams and m3 inverted beams

Hood slabs m3

Vanity slabs, cupboard slabs, cover slabs, etc m3

Isolated beams m3

Bottoms and sides of isolated gutter beams m3

Lintels m3

Stairs including landings, beams and inverted beams m3

Retaining walls in foundations (Provisional) m3

Retaining walls m3

Walls in foundations (Provisional) m3

Walls m3

Balustrade walls m3

Columns in foundations (Provisional) m3

Columns m3

TEST BLOCKS

Making and testing 150 x 150 x 150mm concrete strength test cube No (Provisional)

CONCRETE SUNDRIES

Stripping back head of concrete pile for a height not exceeding ?mm to expose reinforcement including trimming to defined level and bending reinforcement as necessary for casting into pile cap

Cutting off and removing excess length of precast concrete pile as necessary including stripping back for a height not exceeding ?mm to expose reinforcement, trimming to defined level and bending reinforcement as necessary for casting into pile cap

?mm Diameter pile No

? x ?mm Pile No

? x ?mm Hexagonal pile No

Page 17: Model Bill

Pile not exceeding ?kN No

Pile exceeding ?kN and not exceeding ?kN No

Curing surfaces of concrete with ? curing compound applied at a rate of ? l/m2

Horizontal top surfaces. m2

Vertical surfaces. m2

Finishing top surfaces of concrete smooth with a wood float

Finishing top surfaces of concrete smooth with a steel trowel

Finishing top surfaces of concrete smooth with a power float

Finishing top surfaces of concrete to an evenly ribbed non-slip surface

Finishing top surfaces of concrete smooth with a power float with ? hardener added (?kg/m2) and curing with ?

Surface beds, slabs, etc m2

Surface beds, slabs, etc to falls m2

Surface beds, slabs, etc to falls and currents m2

Paving to falls m2

Paving to falls and currents m2

Tops of beams, walls, etc m2

Sloping and splayed tops of beams, walls, etc m2

Wire brushing of concrete surfaces to expose aggregate

Sandblasting of concrete surfaces to expose aggregate

Bush-hammering of concrete surfaces to expose aggregate

Sides of walls m2

Sides of columns m2

Soffits of slabs m2

Sides and soffits of beams m2

Grooves, channels, mortices, sinkings, etc in concrete

? x ?mm Groove in top m

Page 18: Model Bill

? x ?mm Channel in top m

? x Average ?mm segmental channel in top m

Mortice in top, side, etc not exceeding 150mm deep No

? x ? x ?mm Sinking in top No

? MPa non-shrink grout

Bedding approximately ?mm thick under ? x ?mm base plate No including chamfered edges all round

HOLLOW BLOCKS ETC

? spacing tiles to soffits of composite slabs

Solid areas m2

Ribs ?mm wide m

? hollow blocks in composite slabs

? x ? x ?mm Block type ? laid end to end in rows No

? x ? x ?mm Block type ? laid ?mm apart in both directions No

PREFABRICATED CONCRETE BEAMS

? prefabricated prestressed concrete beams in composite slabs

? x ?mm Beams with ? ?mm reinforcing wires, in lengths not m exceeding 5m

? x ?mm Beams with ? ?mm reinforcing wires, in lengths exceeding m 5m and not exceeding 7,5m

? x ?mm Beams with ? ?mm reinforcing wires, in lengths exceeding m ?m and not exceeding ?m

PREFABRICATED BLOCK BEAMS

? type ? prefabricated block beams in composite slabs

? x ?mm Beams with ? ?mm reinforcing bars, in lengths not m exceeding 5m

? x ?mm Beams with ? ?mm reinforcing bars, in lengths exceeding m 5m and not exceeding 7,5m

? x ?mm Beams with ? ?mm reinforcing bars, in lengths exceeding m ?m and not exceeding ?m

Page 19: Model Bill

ROUGH FORMWORK (DEGREE OF ACCURACY III)

ROUGH FORMWORK (DEGREE OF ACCURACY II)

ROUGH FORMWORK TO ? TYPICAL FLOORS (DEGREE OF ACCURACY II)

SMOOTH FORMWORK (DEGREE OF ACCURACY II)

SMOOTH FORMWORK (DEGREE OF ACCURACY I)

SMOOTH FORMWORK TO ? TYPICAL FLOORS (DEGREE OF ACCURACY I)

SPECIAL FORMWORK (DEGREE OF ACCURACY I)

SPECIAL FORMWORK TO ? TYPICAL FLOORS (DEGREE OF ACCURACY I)

Rough formwork to sides

Extra over rough formwork to sides for smooth formwork

Extra over rough formwork to sides for special formwork

Smooth formwork to sides

Special formwork to sides

Strip footings (Provisional) m2

Bases (Provisional) m2

Pile caps (Provisional) m2

Foundation beams (Provisional) m2

Steps m2

Retaining walls m2

Retaining walls circular (not?) exceeding 1m radius m2

Retaining walls with total height exceeding ?m and not exceeding ?m m2 above bearing level

Retaining walls with total height exceeding ?m and not exceeding ?m m2 above bearing level circular (not?) exceeding 1m radius

One face of retaining walls (other face against excavated or existing m2 surfaces)

One face of retaining walls (other face against excavated or existing m2 surfaces) circular (not?) exceeding 1m radius

Page 20: Model Bill

Walls in foundations (Provisional) m2

Walls in foundations circular (not?) exceeding 1m radius m2 (Provisional)

Walls m2

Walls circular (not?) exceeding 1m radius m2

Walls with total height exceeding ?m and not exceeding ?m above m2 bearing level

Walls with total height exceeding ?m and not exceeding ?m above m2 bearing level circular (not?) exceeding 1m radius

Inner face of shaft walls m2

Outer face of walls flush with perimeter of concrete structure m2

Outer face of walls flush with perimeter of concrete structure circular m2 (not?) exceeding 1m radius

Inner face of balustrade walls m2

Inner face of balustrade walls circular (not?) exceeding 1m radius m2

Outer face of balustrade walls m2

Outer face of balustrade walls circular (not?) exceeding 1m radius m2

Inner face of raking balustrade walls over stairs m2

Outer face of raking balustrade walls m2

Inner face of flowing balustrade walls over stairs circular (not?) m2 exceeding 1m radius

Outer face of flowing balustrade walls circular (not?) exceeding 1m m2 radius

Rectangular stub columns in foundations (Provisional) m2

Rectangular columns in foundations (Provisional) m2

Rectangular columns m2

Rectangular columns with total height exceeding ?m and not m2 exceeding ?m above bearing level

Rectangular columns with one face against excavated or existing m2 surfaces in foundations (Provisional)

Rectangular columns with one face against excavated or existing m2

Page 21: Model Bill

surfaces

Rectangular columns with one side splayed m2

Rectangular columns with one side battered m2

Rectangular fins m2

L-shaped columns in foundations (Provisional) m2

L-shaped columns m2

L-shaped columns with total height exceeding ?m and not exceeding m2 ?m above bearing level

Irregular L-shaped columns m2

T-shaped columns m2

T-shaped columns with total height exceeding ?m and not exceeding m2 ?m above bearing level

Irregular T-shaped columns m2

Hexagonal columns m2

Irregular shaped columns with ? right angles and ? obtuse angles m2

Beams m2

Beams circular (not?) exceeding 1m radius m2

Sloping beams m2

Beams with tapering sides m2

Inverted beams m2

Inverted beams circular (not?) exceeding 1m radius m2

Inverted beams above concrete m2

Inverted beams above concrete circular (not?) exceeding 1m radius m2

Inverted beams with battered sides m2

Inverted beams with battered sides above concrete m2

Isolated beams m2

Isolated beams circular (not?) exceeding 1m radius m2

Sloping isolated beams m2

Page 22: Model Bill

Wall beams m2

Isolated wall beams m2

Isolated wall beams circular (not?) exceeding 1m radius m2

Lintels m2

Wallholds m2

Edges exceeding 300mm high m2

Edges exceeding 300mm high circular (not?) exceeding 1m radius m2

Edges, risers, ends and reveals not exceeding 300mm high or wide m

Edges, risers, ends and reveals not exceeding 300mm high or wide m circular (not?) exceeding 1m radius

Sloping and stepped outer edges of stairs not exceeding 300mm high m extreme

Sloping and stepped outer edges of stairs ?mm high extreme m

Sloping and stepped inner edges of kerbs to stairs not exceeding m 300mm high extreme

Flowing and stepped outer edges of stairs ?mm high extreme circular m (not?) exceeding 1m radius

Flowing and stepped inner edges of kerbs to stairs not exceeding m 300mm high extreme circular (not?) exceeding 1m radius

Frustum of a pyramid shaped column cap ? x ?mm at top, ? x ?mm at No bottom and ?mm high overall with top ?mm of cap vertical

Rough formwork to circular columns

Smooth formwork to circular columns

Special formwork to circular columns

?mm Diameter column ?m high No

?mm Diameter column ?m high with cap ? x ? x ?mm high No

?mm Diameter column ?m high with mushroom cap ?mm diameter at No top and ?mm high overall with the top ?mm of cap vertical

Rough formwork to soffits

Extra over rough formwork to soffits for smooth formwork

Extra over rough formwork to soffits for special formwork

Page 23: Model Bill

Smooth formwork to soffits

Special formwork to soffits

Slabs propped up not exceeding 1.5m high m2

User note:

The following two items are to be given only in instances where supports to concrete are required to be left in for periods exceeding those provided for in the preambles.

Slabs with props left in position for a period of ? days. m2

Slabs with props left in position for a period of ? days after casting of m2 slab over.

Slabs propped up exceeding ?m and not exceeding ?m high m2

Slabs exceeding ?mm and not exceeding ?mm thick propped up not m2 exceeding 1.5m high

Slabs exceeding ?mm and not exceeding ?mm thick propped up m2 exceeding ?m and not exceeding ?m high

Slabs over shafts m2

Slabs with sloping soffits propped up not exceeding 1.5m high m2

Slabs with sloping soffits propped up exceeding ?m high and not m2 exceeding ?m high

Slabs with sloping soffits exceeding ?mm and not exceeding ?mm m2 thick propped up not exceeding 1.5m high

Slabs with sloping soffits exceeding ?mm and not exceeding ?mm m2 thick propped up exceeding ?m and not exceeding ?m high

Page 24: Model Bill

Cantilever slabs propped up not exceeding 1.5m high m2

Cantilever slabs propped up exceeding ?m and not exceeding ?m high m2

Hood slabs m2

Vanity slabs, cupboard slabs, cover slabs, etc propped up not m2 exceeding 1.5m high

Landings m2

Landings exceeding ?mm and not exceeding ?mm thick m2

Stairs with sloping soffits m2

Beams propped up not exceeding 1.5m high m2

User note:

The following two items are to be given only in instances where supports to concrete are required to be left in for periods exceeding those provided for in the preambles.

Beams with props left in position for a period of ? days. m2

Beams with props left in position for a period of ? days after casting m2 of beam over.

Beams circular (not?) exceeding 1m radius propped up not exceeding m2 1.5m high

Beams propped up exceeding ?m and not exceeding ?m high m2

Beams propped up exceeding ?m and not exceeding ?m high circular m2

Page 25: Model Bill

(not?) exceeding 1m radius

Beams with sloping soffits propped up not exceeding 1.5m high m2

Beams with sloping soffits propped up exceeding ?m and not m2 exceeding ?m high

Isolated beams propped up not exceeding 1.5m high m2

Isolated beams circular (not?) exceeding 1m radius propped up not m2 exceeding 1.5m high

Isolated beams propped up exceeding ?m and not exceeding ?m high m2

Isolated beams propped up exceeding ?m and not exceeding ?m high m2 circular (not?) exceeding 1m radius

Isolated beams with sloping soffits propped up not exceeding 1.5m m2 high

Isolated beams with sloping soffts propped up exceeding ?m and not m2 exceeding ?m high

Wall beams over openings propped up not exceeding 1.5m high m2

Wall beams over openings propped up exceeding ?m and not m2 exceeding ?m high

Isolated wall beams over openings propped up not exceeding 1.5m m2 high

Isolated wall beams over openings propped up exceeding ?m and not m2 exceeding ?m high

Page 26: Model Bill

Rough formwork to composite hollow block slabs

Soffits of composite slabs propped up not exceeding 1.5m high m2

Soffits of composite slabs propped up exceeding ?m and not m2 exceeding ?m high

Rough formwork to coffered slabs

Smooth formwork to coffered slabs

Soffits of troughed slabs with ?mm wide ribs at ?mm centres propped m2 up not exceeding 1.5m high

Soffits of troughed slabs with ?mm wide ribs at ?mm centres propped m2 up exceeding ?m and not exceeding ?m high

Soffits of adjacent flush surfaces of troughed slabs exceeding ?mm m2 and not exceeding ?mm thick propped up not exceeding 1.5m high

Soffits of adjacent flush surfaces of troughed slabs exceeding ?mm m2 and not exceeding ?mm thick propped up exceeding ?m and not exceeding ?m high

Soffits of coffered slabs with ?mm wide ribs at ?mm centres in both m2 directions propped up not exceeding 1.5m high

Soffits of coffered slabs with ?mm wide ribs at ?mm centres in both m2 directions propped up exceeding ?m and not exceeding ?m high

Soffits of adjacent flush surfaces of coffered slabs exceeding ?mm m2 and not exceeding ?mm thick propped up not exceeding 1.5m high

Soffits of adjacent flush surfaces of coffered slabs exceeding ?mm m2 and not exceeding ?mm thick propped up exceeding ?m and not exceeding ?m high

Page 27: Model Bill

Top and tapered sides of coffer ? x ?mm at top, ? x ?mm at bottom No and ?mm high with all corners rounded

Rough formwork to troughed slabs

Smooth formwork to troughed slabs

Top and sides of troughs ?mm wide at top, ?mm wide at bottom and m ?mm high

Rough retractable shutters

Shutters ? x ?mm high supported on prefabricated beams m

Supporting bearers to prefabricated beams

Bearers propped up not exceeding 1.5m high m

Bearers propped up exceeding ?mm and not exceeding ?mm high m

Rough formwork to sides and soffits

Extra over rough formwork to sides and soffits for smooth formwork

Extra over rough formwork to sides and soffits for special formwork

Smooth formwork to sides and soffits

Special formwork to sides and soffits

Beams propped up not exceeding 1.5m high m2

Beams circular (not?) exceeding 1m radius propped up not exceeding m2 1.5m high

Beams propped up exceeding ?m and not exceeding ?m high m2

Beams propped up exceeding ?m and not exceeding ?m high circular m2 (not?) exceeding 1m radius

Sloping beams propped up not exceeding 1.5m high m2

Sloping beams propped up exceeding ?m high and not exceeding ?m m2

Page 28: Model Bill

high

Beams with battered sides propped up exceeding ?m and not m2 exceeding ?m high

Beams with sloping soffits and tapering sides propped up not m2 exceeding 1.5m high

Beams with sloping soffits and tapering sides propped up exceeding m2 ?m and not exceeding ?m high

Isolated beams propped up not exceeding 1.5m high m2

Isolated beams circular (not?) exceeding 1m radius propped up not m2 exceeding 1.5m high

Isolated beams propped up exceeding ?m and not exceeding ?m high m2

Isolated beams propped up exceeding ?m and not exceeding ?m high m2 circular (not?) exceeding 1m radius

Sloping isolated beams propped up not exceeding 1.5m high m2

Sloping isolated beams propped up exceeding ?m and not exceeding m2 ?m

Lintels propped up not exceeding 1.5m high m2

Lintels propped up exceeding ?m and not exceeding ?m high m2

Formwork to sloping top surfaces

Slabs m2

Page 29: Model Bill

Beams, walls, etc exceeding 300mm wide m2

Beams, walls, etc not exceeding 300mm wide m

Boxing in rough formwork to form

Boxing in smooth formwork to form

Boxing in special formwork to form

User Note:

Attention is drawn to the fact that suitable grouping according to size may be adopted in the event of numerous items occurring

? x ?mm Chamfer along top or bottom edge m

? x ?mm Chamfer along top or bottom edge circular (not?) exceeding m 1m radius

? x ?mm Vertical chamfer at corner m

? x ?mm Horizontal chase or groove in side m

? x ?mm Horizontal chase or groove in side circular (not?) exceeding m 1m radius

? x ?mm Vertical chase or groove in side m

? x ?mm Raking chase or groove in side m

? x ?mm Extreme twice splayed horizontal chase or groove in side m

? x ?mm Extreme twice splayed vertical chase or groove in side m

? x ?mm Rebate in side along top edge m

? x?mm Rebate in side along top edge circular (not?) exceeding 1m m radius

? x ?mm Rebate in side along bottom edge m

? x ?mm Rebate in side along bottom edge circular (not?) exceeding m 1m radius

? x ?mm Vertical rebate m

? x ?mm Extreme splayed rebate in side along top edge m

? x ?mm Extreme splayed rebate in side along top edge circular m (not?) exceeding 1m radius

? x ?mm Extreme splayed rebate in side along bottom edge m

Page 30: Model Bill

? x ?mm Extreme splayed rebate in side along bottom edge circular m (not?) exceeding 1m radius

? x ?mm Extreme vertical splayed rebate m

? x ? x ?mm Recess in side m

? x ? x ?mm Recess in soffit m

Boxing out rough formwork to form

Boxing out smooth formwork to form

Boxing out special formwork to form

User Note:

Attention is drawn to the fact that suitable grouping according to size may be adopted in the event of numerous items occurring

? x ? mm High horizontal projection to side m

? x ? mm High horizontal projection to side circular (not?) exceeding m 1m radius

? x ? mm High horizontal projection to side along top edge. m

? x ? mm High horizontal projection to side along top edge circular m (not?) exceeding 1m radius.

? x ? mm High horizontal projection to side along bottom edge. m

? x ? mm High horizontal projection to side along bottom edge m circular (not?) exceeding 1m radius.

? x ? mm High horizontal projection to side along middle. m

? x ? mm High horizontal projection to side along middle circular m (not?) exceeding 1m radius.

Page 31: Model Bill

? x ? mm High raking projection to side along middle. m

? x ? mm High vertical projection to side along middle. m

? x ?mm Wide vertical projection to side at end or external angle m

? x ?mm Wide vertical projection to side at internal angle m

Rough formwork to form

Smooth formwork to form

Special formwork to form

Opening not exceeding 1m girth through not exceeding 300mm slab No

Opening not exceeding 1m girth through ?mm slab No

Opening exceeding 1m and not exceeding 2m girth through not No exceeding 300mm slab

Opening exceeding 1m and not exceeding 2m girth through ?mm slab No

?mm Diameter opening through ?mm slab No

Rebated opening not exceeding 1m girth overall through ?mm slab No

Rebated opening exceeding 1m and not exceeding 2m girth overall No through ?mm slab

Opening not exceeding 1m girth through not exceeding 300mm wall No or beam

Opening not exceeding 1m girth through ?mm wall or beam No

Opening exceeding 1m and not exceeding 2m girth through not No exceeding 300mm wall or beam

Opening exceeding 1m and not exceeding 2m girth through ?mm wall No or beam

?mm Diameter opening through ?mm wall or beam No

MOVEMENT JOINTS ETC

? slip joints between horizontal concrete and brick surfaces including cement mortar bed

Page 32: Model Bill

Exceeding 300mm wide m2

Not exceeding 300mm wide m

Expansion joints with ? softboard between vertical concrete surfaces

Expansion joints with ? softboard between vertical concrete and brick surfaces

?mm Joints exceeding 300mm high m2

?mm Joints not exceeding 300mm high m

?mm Rebated joints ?mm wide and ?mm high through slabs etc m

Saw cut joints

? x ?mm Saw cut joints in top of concrete m

? x ?mm Saw cut joints in two operations in top of concrete m

Vertical joggle construction joints through concrete including thick cement slurry to one face

Horizontal joggle construction joints through concrete including thick cement slurry to one face

Surface beds not exceeding 300mmm thick m

Slabs not exceeding 300mm thick m

Slabs ?mm thick m

Walls not exceeding 300mm thick m

Walls ?mm thick m

REINFORCEMENT

REINFORCEMENT (PROVISIONAL)

Mild steel reinforcement to structural concrete work

High tensile steel reinforcement to structural concrete work

High tensile steel reinforcement to structural concrete work in slides

40mm Diameter bars t

32mm Diameter bars t

25mm Diameter bars t

Page 33: Model Bill

20mm Diameter bars t

16mm Diameter bars t

12mm Diameter bars t

10mm Diameter bars t

8mm Diameter bars t

?mm Diameter bars in lengths exceeding 13 and not exceeding 18m t

?mm Diameter bars in lengths exceeding 18 and not exceeding 19m t

?mm Diameter bars curved t

?mm Diameter bars helical t

High tensile steel dowel bars

?mm Diameter dowel bar ?mm long with one end embedded ?mm No deep in side of concrete at expansion joint and other end greased and wrapped in polythene sheeting including hole through formwork

Fabric reinforcement

Type ? fabric reinforcement in concrete surface beds, slabs, etc m2

Type ? fabric reinforcement in concrete walls m2

Type ? fabric reinforcement in pre-bent cages in concrete beams. m2

POST-TENSIONED REINFORCEMENT

POST-TENSIONED REINFORCEMENT (PROVISIONAL)

User Note:

A detailed specification pertinent to this work is to be inserted. The nature of the work and the general position and accessibility of stressing anchors shall be described

?mm Diameter high tensile steel tendons including pre-lubricated m sheaths, supporting chairs, marking of positions, etc

Dead anchor suitable for ?mm tendon including protection against No corrosion

Stressing anchor suitable for ?mm tendon including protection against No corrosion and filling in recess

Page 34: Model Bill

Intermediate stressing anchor suitable for ?mm tendon including No sleeve and protection against corrosion (temporary tensioning pocket in concrete elsewhere)

BILL ?

PRECAST CONCRETE

SUPPLEMENTARY PREAMBLES

Sizes:

Blocks, sills, etc measured linear shall be made in suitable lengths. Large size setting out drawings shall be prepared where necessary and submitted to the architect for approval before moulds are made

General:

Where kerbstones, blocks, etc are laid in ground descriptions shall be deemed to include necessary excavation, filling in and ramming

PRECAST CONCRETE

User note:

The following precast concrete paving descriptions are only to be used when paving slabs etc are purpose made to detailed specifications and other than those available ex stock

Slab paving of ? x ? x ?mm precast concrete slabs with ? finish laid on ?mm thick river sand bed including preparation of ground or filling

Paving laid with butt joints m2

Paving laid with butt joints to falls m2

Paving laid with ?mm wide joints flush pointed with class I mortar m2

Circular cutting m

Finished edge m

? x ? x ?mm Precast concrete paving slabs with ? finish including bedding, jointing and pointing

Paving of slabs laid on ?mm thick mortar bed on concrete with butt m2 joints

Page 35: Model Bill

Paving of slabs laid on ?mm thick mortar bed on concrete with ?mm m2 wide joints flush pointed

Circular cutting m

Finished edge m

? x ? x ?mm Precast concrete paving slabs with ? finish

Paving of slabs laid loose with open joints on polythene bags filled m2 with stabilized sand/cement mixture under corners of slabs on waterproofing to roofs etc

Paving of slabs laid loose with open joints on "?" patent supports m2 under corners of slabs on waterproofing to roofs etc

Circular cutting m

Finished edge m

Hudson and Cray precast concrete fencing finished smooth on exposed surfaces

? precast concrete fencing finished smooth on exposed surfaces

2,4m High palisade fencing with top and bottom rails, palings 2,5m m long at 145mm centres and posts 3m long at 2m centres cast in and including 400 x 500 x 650mm concrete blocks in ground

Winblok modular precast concrete window surrounds etc finished smooth on exposed surfaces including bedding, jointing and pointing

Window surrounds are to be built into brick walls and pointed all m round on both sides with 10 x 10mm square recessed joints

Prices are to include for building in as single units or combinations in m patterns of two or more window units and for bedding solid all round in mortar and pointing

Note: Aluminium infill windows, glazing and pointing with sealing compound are measured elsewhere

590 x 590 x 260mm Type WA 260 window surround No

? x ? x ?mm Type ? window surround No

590 x 590 x 260mm Type WA Q260 quadrant window surround No

? x ? x ?mm Type ? triangular window surround No

Page 36: Model Bill

515 x 515 x 40mm Type WAP flush panel fixed in surround with No silicone sealant adhesive

Precast concrete left rough from the mould including bedding, jointing and pointing

? x ?mm Thick duct cover slabs in suitable lengths closely butted at m ends including bedding edges along both sides (reinforcement elsewhere)

? x ?mm Thick seat slabs in ?mm lengths closely butted at ends m including bedding edges all round (reinforcement elsewhere)

? x ?mm Thick counter slabs in ?mm lengths closely butted at ends m including bedding edges at ends and along one side (reinforcement elsewhere)

? x ? x ?mm Padstone reinforced with and including three 12mm No diameter mild steel stirrups each ?mm girth

? x ? x ?mm Block with standard steel foot scraper cast into top laid No in ground

? x ? x ?mm Thick cover slab including bedding edges all round No (reinforcement elsewhere)

? x ? x ?mm Thick seat slab including bedding ends (reinforcement No elsewhere)

? x ? x ?mm Thick slab in stepped floor closely butted along sides No including bedding ends (reinforcement elsewhere)

? x ? x ?mm High lintel including building in over opening No (reinforcement elsewhere)

? x ? x ?mm High lintel twice chamfered and once throated along No length including building in over opening (reinforcement elsewhere)

? x ? x ?mm High beam including bedding ends (reinforcement No elsewhere)

?mm Diameter hole through ?mm thick unit No

Precast concrete finished smooth on exposed surfaces including bedding, jointing and pointing

Precast light grey brushed terrazzo finished on exposed surfaces including bedding, jointing and pointing

Precast white polished terrazzo finished on exposed surfaces including bedding, jointing and pointing

? x ?mm Thick overall copings weathered on top to ?mm thick along m

Page 37: Model Bill

one edge with drip groove in bottom along one edge

? x ?mm Thick overall copings twice weathered on top to ?mm thick m along both edges with drip groove in bottom along both edges

? x ?mm Thick overall window sills weathered on top for a width of m ?mm to ?mm thick along front edge with drip groove in bottom

? x ?mm Thick overall window sills with ?mm wide weathered rebate m in top and drip groove in bottom

Precast light grey brushed terrazzo including bedding, jointing and pointing

Precast white polished terrazzo including bedding, jointing and pointing

? x ? x ?mm Thick riser finished on face No

? x ? x ?mm Thick riser finished on face, one end and ?mm wide No return at other end

? x ? x ?mm Thick tread finished on top, front edge, one end and No ?mm wide return along bottom edge with ? x ?mm non-slip carborundum insert in top

? x ? x ?mm High beam finished on both sides and soffit No (reinforcement elsewhere)

? x ? x ?mm High pergola beam finished all round (reinforcement No elsewhere)

?mm Diameter hole through ?mm thick unit No

? x ?mm Hole through ?mm thick unit No

Notch ?mm girth in ?mm thick unit No

Precast concrete wall cladding to external facades of ?mm thick slabs with ? finish on exposed surfaces and continuous joints in both directions including bedding, jointing, pointing, cramps, dowels, mortices and grouting

User note:

Where the above or any other designed precast concrete facings, claddings, etc are to be included in the bill of quantities then the relevant supplementary preambles in the form of architect's /

engineer's project specifications etc are to be included here. Items are to be given with brief descriptions referring to detailed drawings annexed to the bill of quantities where necessary

Page 38: Model Bill

Wall cladding of slabs not exceeding 0,5m2 on face m2

Wall cladding of slabs exceeding ?m2 and not exceeding ?m2 on face m2

Finished edge to ?mm thick wall cladding m

Precast concrete cladding units etc to external facades with ? finish on exposed surfaces including jointing, pointing with polysulphide sealing compound, cramps, straps, anchor bolts, mortices, etc

Unit type ? ? x ?mm high (drawing No ?) No

Joint sealants

? silicone sealing compound in ?mm wide joints between units m including backing strips, bond breaker, primer, etc

? polysulphide sealing compound in ?mm wide joints between units m including backing strips, bond breaker, primer, etc

Jointing strips, fixing sundries, etc

? x ?mm Galvanised steel water bars bedded in and including "?" m mastic in vertical grooves between units (grooves elsewhere)

? x ?mm Aluminium jointing strips bedded in and including "?" m mastic in vertical grooves between units (grooves elsewhere)

? x ?mm Galvanised hoop iron strap ?mm girth with one end No embedded in precast concrete and other end bent back and twice shot pinned to concrete

? x ?mm Galvanised steel flat section bracket ?mm girth ? holed for No bolts and with one end embedded in precast concrete

? x ? x ?mm Galvanised steel angle section bracket ?mm long ? No holed for bolts

? expansion bolt No

Mild steel reinforcement to precast concrete

8mm Diameter bars t

High tensile steel reinforcement to precast concrete

32mm Diameter bars t

25mm Diameter bars t

20mm Diameter bars t

Page 39: Model Bill

16mm Diameter bars t

12mm Diameter bars t

10mm Diameter bars t

8mm Diameter bars t

Fabric reinforcement to precast concrete

Type ? fabric reinforcement in cover slabs m2

BILL NO. ?

MASONRY

SUPPLEMENTARY PREAMBLES

BRICKWORK

Sizes in descriptions

Where sizes in descriptions are given in brick units, "one brick" shall represent the length and "half brick" the width of a brick

Hollow walls etc

Descriptions of hollow walls shall be deemed to include leaving every fifth perpend of the bottom course of the external skin open as a weep hole.

Walls in two skins described as "bagged and sealed" shall be deemed to include having the outer face of the inner skin bagged with 1:6 cement and sand mixture and sealed with two coats "Brixeal" bitumen emulsion waterproofing coating.

User note:

The above preamble generally applies for works in hot and humid coastal areas

Face bricks

Bricks shall be ordered timeously to obtain uniformity in size and colour

Page 40: Model Bill

Pointing

Descriptions of recessed pointing to fair face brickwork and face brickwork shall be deemed to include square recessed, hollow recessed, weathered pointing, etc

BLOCKWORK

Concrete masonry units

Blocks are to be either solid or hollow modular dense concrete masonry units having a compressive strength of 7 MPa

Wall ties for blockwork

Wall ties shall be polypropylene "Permaties" complying with BS 76377. Ties for hollow walls shall be of sufficient length to allow not less than 75mm of each end to be built into the blockwork. Ties are to be spaced at intervals of not more than 1m in the horizontal direction and not more than 400mm staggered in the vertical direction except at openings, vertical joints or ends of walls where they are to be placed vertically above each other

Blockwork

Blockwork shall comply with SABS 0145 "Concrete Masonry Construction"

Surfaces to be plastered shall have joints raked out to a depth of at least 10mm to provide a key. Cavities of hollow walls shall be kept free of mortar droppings or other undesirable matter. Every second perpend of the bottom course of the external skin of hollow walls shall be left open as a weep hole

Standard complementary blocks

Descriptions of blockwork shall be deemed to include standard complementary blocks such as corner, three-quarter, half and quarter blocks required in the construction of corners, reveals, jambs, ends, etc to solid and hollow walls and for bonding as necessary

Page 41: Model Bill

DECORATIVE BLOCKS

Blocks shall be of approved manufacture, sound, well burnt or cured and uniform and true in size, shape and colour

SAMPLES

Samples of all masonry building units, except those for walls described as "load bearing", shall consist of a minimum of 6 units. Samples of building units to be used in walls described as "load bearing" shall consist of 30 units from every 30 000 units delivered to site

FOUNDATIONS (PROVISIONAL)

SUPERSTRUCTURE

Brickwork of NFX bricks (14 MPa nominal compressive strength) in class I mortar

Brickwork of concrete bricks in class I mortar

Brickwork of calcium silicate bricks in class I mortar

Brickwork of NFP bricks in class II mortar

Brickwork of concrete bricks in class II mortar

Brickwork of calcium silicate bricks in class II mortar

Brickwork of NFPE bricks (? MPa nominal compressive strength) in class I mortar in loadbearing walls etc

Brickwork of NFXE bricks (? MPa nominal compressive strength) in class I mortar in loadbearing walls etc

User note:

Attention is drawn to the fact that separate items for brickwork in lintels are to be given only when the type of brick and/or the mortar mix differs from that of the adjoining brickwork

Piers m3

L-shaped piers m3

H-shaped piers m3

?mm Cut linings to concrete m2

?mm Cut linings to concrete circular on plan m2

Page 42: Model Bill

Brick-on-edge walls m2

Half brick walls m2

Half brick walls circular on plan m2

Half brick walls against existing surfaces m2

Half brick walls against waterproofing m2

Half brick walls against waterproofing circular on plan m2

Half brick walls in beamfilling m2

Half brick walls in beamfilling circular on plan m2

Half brick linings to concrete m2

Half brick linings to concrete circular on plan m2

Half brick linings ?mm away from concrete m2

Half brick linings ?mm away from concrete circular on plan m2

One brick walls m2

One brick walls circular on plan m2

One brick walls against existing surfaces m2

One brick walls in beamfilling m2

One brick walls in beamfilling circular on plan m2

One brick walls of two half brick skins bagged and sealed m2

?mm Hollow walls of two half brick skins (no wire ties) m2

?mm Hollow walls of two half brick skins including wire ties m2

?mm Hollow walls of two half brick skins including wire ties circular m2 on plan

?mm Solid walls m2

One and a half brick walls m2

One and a half brick walls circular on plan m2

?mm Hollow walls of one half brick and one one brick skins including m2 wire ties

?mm Hollow walls of one half brick and one one brick skins including m2

Page 43: Model Bill

wire ties circular on plan

Two brick walls m2

Two brick walls circular on plan m2

Half brick kerbs ?mm high m

Half brick kerbs ?mm high circular on plan m

One brick kerbs ?mm high m

One brick kerbs ?mm high circular on plan m

User note:

Attention is drawn to the fact that separate items for brickwork in lintels are to be given only when the type of brick and/or mortar mix differs from that of the adjoining brickwork

Half brick walls in lintels m2

One brick walls in lintels m2

?mm Solid walls in lintels m2

One and a half brick walls in lintels m2

Two brick walls in lintels m2

BRICKWORK SUNDRIES

Cutting toothings and bonding new brickwork to existing m2

Extra for building brickwork to battered face with each course set m2 back ?mm

Extra for building brickwork to battered face with sloping bed joints m2

Extra for building brickwork to oversailing face with each course m2 projecting ?mm

Splayed mortar fillet one course high in ?mm cavity m

Splayed mortar fillet two courses high in ?mm cavity m

Closing ?mm cavity of hollow wall vertically with brickwork half m brick wide

Closing ?mm cavity of hollow wall horizontally with one course of m brickwork

Page 44: Model Bill

Closing ?mm cavity of hollow wall horizontally with two courses of m brickwork

Closing ?mm cavity at raking top of hollow wall with two courses of m brickwork

? x ?mm Horizontal flue in brickwork including rendering smooth in m mortar

? x ?mm Vertical flue in brickwork including rendering smooth in m mortar

? x ?mm Raking flue in brickwork including rendering smooth in m mortar

Extra for rough segmental arch in half brick wall ?mm span and ?mm No high formed of ? brick-on-edge header ring(s) including centre

Extra for rough segmental arch in one brick wall ?mm span and ?mm No high formed of ? brick-on-edge header ring(s) including centre

Extra for ?mm diameter rough semi-circular arch in half brick wall No formed of ? brick-on-edge header ring(s) including centre

Extra for ?mm radius rough semi-circular arch in one brick wall No formed of ? brick-on-edge header ring(s) including centre

Extra for ?mm diameter rough bullseye arch in half brick wall formed No of ? brick-on-edge header ring(s) including centre

Extra for ?mm diameter rough bullseye arch in one brick wall formed No of ? brick-on-edge header ring(s) including centre

Extra for ?mm diameter ?mm deep rough semi-circular niche in No brickwork including centre

Fair face to brickwork in horizontal stretcher bond pointed with flush horizontal and vertical joints

Fair face to brickwork in horizontal stretcher bond pointed with recessed horizontal and flush vertical joints

Fair face to brickwork in horizontal stretcher bond pointed with recessed horizontal and vertical joints

Extra for fair face m2

Half brick walls pointed on both sides m2

Bagging of 1:3 cement and sand mixture

Cement wash of 1:3 liquid cement and sand mixture applied with a brush

Page 45: Model Bill

On brick walls, piers, etc. m2

On concrete walls, columns, etc including removing fins, m2 irregularities, etc.

On concrete ceilings, beams, etc including removing fins, m2 irregularities, etc.

Joint forming material in movement joints

?mm Fibre board built in vertically between brick skins m2

?mm Fibre board built in vertically through brick walls m2

?mm Bitumen impregnated fibre board built in vertically between m2 brick skins

?mm Bitumen impregnated fibre board built in vertically through m2 brick walls

?mm Expanded polystyrene (density ?kg per m3) built in vertically m2 between brick skins

?mm Expanded polystyrene (density ?kg per m3) with one tear off m2 strip built in vertically through brick walls

Steel bar reinforcement

?mm Diameter mild steel bars built in horizontally t

?mm Diameter high tensile steel bars built in horizontally t

?mm Diameter galvanised mild steel bars built in horizontally t

?mm Diameter galvanised high tensile steel bars built in horizontally t

Brickwork reinforcement

75mm Wide reinforcement built in horizontally m

150mm Wide reinforcement built in horizontally m

230mm Wide reinforcement built in horizontally m

?mm Wide reinforcement built in horizontally circular on plan m

?mm Wide reinforcement built in vertically m

Page 46: Model Bill

? prestressed fabricated lintels

100 x 70mm Lintels in lengths not exceeding 3m m

110 x 75mm Lintels in lengths not exceeding 3m m

150 x 70mm Lintels in lengths not exceeding 3m m

150 x 75mm Lintels in lengths not exceeding 3m m

? x ?mm Lintels in lengths exceeding 3m and not exceeding 4,5m m

? x ?mm Lintels in lengths exceeding ?m and not exceeding ?m m

Turning pieces

?mm Wide turning piece to lintels etc m

Galvanised wire ties etc

4mm Diameter roof tie 2m girth bent double with one end fixed to No timber and other end built into brickwork

4mm Diameter roof tie 2m girth bent double with one end fixed to No timber and other end cast into concrete

Galvanised hoop iron cramps, ties, etc

40 x 1,6mm "Tibond" wall tie strips shot pinned to concrete and with m ties bent out and built into brickwork

30 x 1,6mm Cramp 500mm long with one end fixed to wood and No other end built into brickwork

30 x 1,6mm Wall tie 500mm long with one end cast into concrete and No other end built into brickwork

30 x 1,6mm Wall tie 500mm long with one end shot pinned to No concrete and other end built into brickwork

30 x 1,6mm Roof tie 1,5m long with one end fixed to timber and other No end built into brickwork

30 x 1,6mm Roof tie 1,5m long with one end fixed to timber and other No end cast into concrete

30 x 1,6mm Ceiling hanger 1m long with one end fixed to timber and No other end shot pinned to concrete

Air bricks etc

229 x 76mm Clay vermin proof air brick No

229 x 152mm Clay vermin proof air brick No

Page 47: Model Bill

Set of ? ? x ?mm clay vermin proof air bricks No

230 x 160mm Cement air brick No

233 x 175mm Foam plastic air vent No

262 x 185mm Fibrous plaster air vent No

FACE BRICKWORK

? face bricks pointed with flush horizontal and vertical joints

? face bricks pointed with recessed horizontal and flush vertical joints

? face bricks pointed with recessed horizontal and vertical joints

? face bricks (? MPa nominal compressive strength) pointed with ? horizontal and vertical joints

User Note:

Where the radius of circular work is less than 1m the use of header courses, cut bricks or specially made bricks is to be ascertain and described as such

Extra over brickwork for face brickwork m2

Extra over brickwork for face brickwork in foundations (Provisional) m2

Extra over brickwork circular on plan exceeding 2m radius. m2

Extra over brickwork for face brickwork circular on plan not m2 exceeding 2m radius.

Extra over brickwork for face brickwork in soldier courses m2

Extra over brickwork for face brickwork in soldier courses circular on m2 plan exceeding 2m radius.

Extra over brickwork for face brickwork in soldier courses circular m2 plan not exceeding 2m radius.

Page 48: Model Bill

Extra over brickwork in NFPE bricks for face brickwork m2

Extra over brickwork in NFXE bricks for face brickwork m2

?mm Cut linings to concrete m2

?mm Cut linings to concrete circular on plan exceeding 2m radius. m2

? mm Cut linings to concrete circular on plan not exceeding 2m m2 radius.

Half brick walls pointed on both sides m2

One brick walls in English bond pointed on both sides m2

Extra over brickwork for brick-on-flat header course band m

Extra over brickwork for brick-on-edge header course band m

Extra over brickwork for brick-on-end soldier course band m

Extra over brickwork for brick-on-edge header course lintel m

Extra over brickwork for brick-on-edge header course lintel pointed m on face and ?mm soffit

Extra over brickwork for brick-on-end soldier course lintel m

Extra over brickwork for brick-on-end soldier course lintel pointed on m face and ?mm soffit

Extra over brickwork for horizontal corbelled band ? courses high and m ?mm projection pointed on face and soffits

Fair raking cutting m

Fair splay cutting m

Fair stepped cutting and fitting over treads and risers m

Fair circular cutting m

Fair cutting at squint quoin or birdsmouth angle m

Fair cutting to both sides at mitred squint quoin or birds-mouth angle m

Page 49: Model Bill

Cutting toothings and bonding new face brickwork to existing m

Fair cutting and fitting around pipe not exceeding 100mm diameter No

Fair cutting and fitting around pipe exceeding ?mm and not exceeding No ?mm diameter

Brick-on-edge header course copings, sills, etc of ? face bricks pointed with recessed joints on all exposed faces

Coping on top of half brick wall m

Coping on top of one brick wall m

Coping on top of one and a half brick wall m

Coping on raking top of ? brick wall m

Coping on top of ? brick wall circular on plan exceeding 2m radius. m

Coping to top of ? brick wall circular on plan not exceeding 2m m radius.

?mm Wide sill set level and slightly projecting m

?mm Wide sill set sloping and slightly projecting m

Fair arches, recesses, etc of ? face bricks pointed with flush joints

Fair arches, recesses, etc of ? face bricks pointed with recessed joints

Extra over brickwork for segmental arch in half brick wall ?mm span No and ?mm high formed of ? brick-on-edge header course ring(s) pointed on soffit and ? side(s) including centre

Extra over brickwork for segmental arch in one brick wall ?mm span No and ?mm high formed of ? brick-on-edge header course ring(s) pointed on soffit and ? side(s) including centre

Extra over brickwork for ?mm diameter semi-circular arch in one No brick wall formed of ? brick-on-edge header course ring(s) pointed on soffit and ? side(s) including centre

Extra over brickwork for ?mm diameter bullseye arch in one brick No wall formed of ? brick-on-edge header course ring(s) pointed in opening and ? side(s) including centre

Extra over brickwork for semi-circular niche ?mm diameter and ?mm No deep pointed on exposed faces including centre

Page 50: Model Bill

BLOCKWORK

Blockwork in class II mortar

Blockwork in class I mortar

Blockwork in class ? mortar with cores filled solid with mortar

?mm Cut block walls m2

?mm Walls m2

?mm Walls in foundations (Provisional) m2

?mm Walls circular on plan m2

?mm Walls against waterproofing m2

?mm Walls against waterproofing in foundations (Provisional) m2

?mm Walls in beamfilling m2

?mm Walls against concrete (no ties) m2

?mm Walls ?mm away from concrete (no ties) m2

?mm Walls with blocks threaded over vertical reinforcement m2

?mm Hollow walls of two ?mm skins including wire ties m2

?mm Hollow walls of two ?mm skins including wire ties in m2 foundations (Provisional)

?mm Hollow walls of ?mm and ?mm skins including wire ties m2

?mm Hollow walls of ?mm and ?mm skins including wire ties in m2 foundations (Provisional)

Extra over ?mm hollow walls of two ?mm skins for internal stiffener m piers ?mm wide

190mm Lintel one course high of ? x ? x ?mm U-blocks m

BLOCKWORK SUNDRIES

Fair face to blockwork pointed with flush horizontal and vertical joints

Fair face to blockwork pointed with recessed horizontal and vertical joints

Extra for fair face m2

Page 51: Model Bill

Bagging of 1:3 cement and sand mixture

Cement wash of 1:3 liquid cement and sand mixture applied with a brush

On block walls m2

Mortar filling including necessary formwork to soffits

To single hollow core of 90mm hollow block No

To single hollow core of 140mm hollow block No

To single hollow core of 190mm hollow block No

Wall bonding ties

6mm Diameter mild steel rod wall bonding tie ?mm girth four times No bent and built horizontally into blockwork at wall intersections, construction joints, etc

70mm Wide "Mentis Mentex 130" expanded metal wall bonding tie No ?mm long built horizontally into blockwork at wall intersections, construction joints, etc

FACE BLOCKWORK

? x ? x ?mm ? face blocks in class II mortar pointed with flush horizontal and vertical joints

? x ? x ?mm ? face blocks in class II mortar pointed with recessed horizontal and vertical joints

Extra over ?mm skin of blockwork for face blockwork m2

?mm Cut block linings to concrete m2

?mm Block walls pointed on both sides m2

?mm Block walls pointed on both sides in foundations (Provisional) m2

?mm Block walls pointed on both sides circular on plan m2

?mm Lintel one course high of ? x ? x ?mm U-blocks pointed on soffit m and ? side(s)

?mm Coping one course high of ? x ? x ?mm inverted U-blocks m pointed on top and both sides

?mm Sill of ? x ? x ?mm splayed sill blocks pointed on splayed top m and one side

? x ?mm Piers of ? x ? x ?mm blocks pointed all round m

Page 52: Model Bill

Capping to ? x ?mm pier of ? ? x ? x ?mm splayed blocks pointed on No splayed top and all sides

QUARRY TILES

? x ? x ?mm ? quarry tiles on concrete with continuous joints in both directions and pointed on all exposed surfaces

? x ? x ?mm ? quarry tiles on brickwork with continuous joints in both directions and pointed on all exposed surfaces

?mm Wide sill of ? row(s) of tiles set flat and slightly projecting m

?mm Wide sill of ? row(s) of tiles set sloping and slightly projecting m

?mm Wide bullnosed edge sill of ? row(s) of tiles set flat and slightly m projecting

?mm Wide bullnosed edge sill of ? row(s) of tiles set sloping and m slightly projecting

?mm Wide coping of ? row(s) of tiles set flat and slightly projecting m

?mm Wide coping of ? row(s) of cut tiles set flat and slightly m projecting

?mm Wide coping of ? row(s) of tiles set sloping and slightly m projecting

?mm Wide saddleback coping of two rows of tiles set sloping and m slightly projecting

NUTEC-CEMENT/FIBRE-CEMENT WINDOW SILLS

Natural grey sills in single lengths bedded in class I mortar including metal fixing lugs etc

Slate grey sills in single lengths bedded in class I mortar including metal fixing lugs etc

? x ?mm Wide sills set flat and slightly projecting m

? x ?mm Wide sills set sloping and slightly projecting m

DECORATIVE SCREEN WALLS AND GRILLES

Screen walls of type ? grille blocks in class II mortar pointed with flush joints

Screen walls of type ? grille blocks in class II mortar pointed with recessed joints

? Walls pointed on both sides m2

Page 53: Model Bill

? Walls pointed on both sides and in openings m2

GLASS BLOCK WALLS

? x ? x 80mm ? glass blocks bedded and jointed in slow-setting class I mortar with continuous joints in both directions pointed in tinted mortar on both sides with flush horizontal and vertical joints

? x ? x ?mm ? glass blocks bedded and jointed in slow-setting class I mortar with continuous joints in both directions pointed in tinted mortar on both sides with recessed horizontal and vertical joints

?mm Walls m2

?mm Walls circular on plan m2

Sundries to glass block walls

Two layers type FV damp proof course horizontal slip joints below m2 glass blocks

?mm Expanded polystyrene (density ?kg per m3) horizontally m2 between top of glass blocks and structure

?mm Expanded polystyrene (density ?kg per m3) vertically between m2 glass blocks and structure

8mm Diameter galvanised mild steel bar reinforcement horizontally t and vertically

PAVING

Paving of ? paving bricks with butt joints on ?mm thick river sand bed with sand and cement mixture swept into joints and hosed down including preparation of ground or filling

Paving of ? paving bricks with open joints on ?mm thick river sand bed with sand and cement mixture swept into joints, hosed down and pointed with slightly keyed joints including preparation of ground or filling

Paving of ? x ? x ?mm thick precast concrete paving blocks with butt joints on ?mm thick river sand bed with sand swept into joints including preparation of ground or filling

Paving in stretcher bond m2

Paving in stretcher bond to falls m2

Paving in ? bond m2

Paving in ? bond to falls m2

Page 54: Model Bill

75mm Wide brick-on-edge edging on ?mm thick mortar bed m

110mm Wide brick-on-end edging on ?mm thick mortar bed m

220mm Wide brick-on-flat header course edging on ?mm thick mortar m bed

220mm Wide brick-on-flat header course edging on ?mm thick mortar m bed circular on plan

220mm Wide brick-on-edge header course edging on ?mm thick m mortar bed

220mm Wide brick-on-edge header course edging on ?mm thick m mortar bed circular on plan

?mm Wide block-on-edge edging on ?mm thick mortar bed m

200mm Wide block-on-flat header course edging on ?mm thick m mortar bed

200mm Wide block-on-edge header course edging on ?mm thick m mortar bed

Paving of ? paving bricks

Paving in stretcher bond on 25mm thick mortar bed m2

Paving in ? bond on ?mm thick mortar bed m2

Paving in stretcher bond on average ?mm thick mortar bed to falls m2

75mm Wide brick-on-edge edging on ?mm thick mortar bed m

110mm Wide brick-on-end edging on ?mm thick mortar bed m

220mm Wide brick-on-flat header course edging on ?mm thick mortar m bed

220mm Wide brick-on-flat header course edging on ?mm thick mortar m bed circular on plan

220mm Wide brick-on-edge header course edging on ?mm thick m mortar bed

220mm Wide brick-on-edge header course edging on ?mm thick m mortar bed circular on plan

?mm Wide brick-on-flat header course treads on ?mm thick mortar m bed

?mm High brick-on-flat risers on ?mm thick mortar bed m

Page 55: Model Bill

?mm Wide treads of brick-on-edge header course and brick-on-edge m stretcher course on ?mm thick mortar bed

?mm Wide brick-on-edge header course treads of one full and one cut m course on ?mm thick mortar bed

Fair circular cutting m

Fair cutting and fitting around pipe not exceeding 100mm diameter No

?mm Thick double zig-zag (shape S-A) interlocking precast concrete paving blocks complying with SABS 1058 laid with butt joints on ?mm thick river sand bed with sand swept into joints including preparation of ground or filling

Light grey "Grinaker G-blocks" interlocking precast concrete (35 MPa) paving blocks laid with butt joints on ?mm thick river sand bed with sand swept into joints including preparation of ground or filling

? interlocking precast concrete paving blocks laid with butt joints on ?mm thick river sand bed with sand swept into joints including preparation of ground or filling

Paving of ?mm thick blocks including edge blocks m2

Paving of ?mm thick blocks including edge blocks to falls and cross m2 falls

Extra for contrasting colour blocks as marker lines m

Fair circular cutting m

? x ? x ?mm Precast concrete paving slabs laid on ?mm thick river sand bed including preparation of ground or filling

? x ? x ?mm Precast concrete paving slabs with ? finish laid on ?mm thick river sand bed including preparation of ground or filling

Paving of slabs laid with butt joints m2

Paving of slabs laid with ?mm wide joints jointed with mortar and m2 flush pointed

Fair circular cutting m

? x ? x ?mm Precast concrete paving slabs

? x ? x ?mm Precast concrete paving slabs with ? finish

Paving of slabs laid with butt joints on ?mm thick mortar bed m2

Paving of slabs laid with ?mm wide joints jointed with mortar and m2

Page 56: Model Bill

flush pointed on ?mm thick mortar bed

Paving of slabs laid loose with open joints on polythene bags filled m2 with stabilized sand/cement mixture under corners on waterproofing to roofs etc

Paving of slabs laid loose with open joints on "?" patent supports m2 under corners on waterproofing to roofs etc

Fair circular cutting m

? x ? x ?mm ? quarry tiles with continuous joints in both directions flush pointed on all exposed surfaces

? x ? x ?mm ? quarry tiles in stretcher bond pattern flush pointed on all exposed surfaces

Paving on ?mm thick mortar bed m2

Paving on average ?mm thick mortar bed to falls m2

Extra for ?mm wide band, margin, etc in contrasting colour m

Fair circular cutting m

?mm Wide treads on ?mm thick mortar bed m

?mm Wide treads with bullnosed edge on ?mm thick mortar bed m

?mm High risers on ?mm thick mortar bed m

RUBBLE WALLING

Rubble walling of uncoursed random stone including facing and pointing on one side

Rubble walling of uncoursed random stone including facing and pointing on both sides

Mass and irregular walling (facing and pointing elsewhere) m3

?mm Walls m2

?mm Walls circular on plan m2

?mm Walls in beamfilling m2

Average ?mm thick battered walls m2

?mm Linings to brickwork including wire ties m2

?mm Linings to concrete including wire ties m2

? x ?mm Copings m

Page 57: Model Bill

? x ?mm Sloping sills m

Extra for rectangular recess ? x ? x ?mm deep pointed on exposed No faces including turning piece

Facing and pointing

To mass and irregular work m2

To tops, ends and reveals of walls m2

Sundries

Trimming face of rubble walling to receive in-situ finishes etc m2

Angles pitched from one face m

Angles pitched from both faces m

? x ?mm Vertical flue in rubble walling including rendering smooth m in mortar

?mm Wide turning piece to lintels etc m

?mm Wide centre to segmental arch ?mm span x ?mm high above No springing line

STONEWORK

SUPPLEMENTARY PREAMBLES

Slate, marble, granite, etc

Slate, marble, granite, etc is to be best quality stone from an approved quarry free from cracks and other defects and equal to samples to be submitted to and approved by the architect. Each stone is to hold its fullsize, square to the back and to be set on its natural quarry bed

Setting out

Care shall be exercised in setting out the work, the preparation of templets and the checking of the detail drawings. All measurements shall be taken on the site where necessary and the full size setting out of each course shall be done at the yard so as to ensure the proper fitting of each stone

Before putting any work in hand the contractor is to submit to the

Page 58: Model Bill

architect for his approval details of the manner in which he proposes to set out the slabs and joints in all wall facings, pavings, sills, treads, etc together with samples of grain or pattern matching

Face labours

Face labours are to match samples to be submitted to and approved by the architect

Arrises are to be clean and sharp except to treads and thresholds where they are to be slightly rounded

Bedding and jointing

Slate, marble, granite and other floor paving and wall linings are to be bedded solidly on the mortar thicknesses described and are to have tightly fitting butt joints unless otherwise stated

Where stonework is to be fixed with adhesive, the adhesive is to be "Ardurit X76" or other approved. The contractor will be liable for any defects to the slate, marble and granite arising from the use of the adhesive

Where soffit linings are suspended the suspension system must be concealed and must be submitted to the architect for approval before work commences

Where tolerance screws are required these are to be stainless steel expanding bolt type with matching stainless steel bracket and PVC clad dowel with nuts and washers etc

Damaged work

All stonework damaged must be discarded and replaced at the contractor's expense. No touching up will be permitted except in exceptional cases with the architect's consent

Descriptions

Descriptions of stonework shall be deemed to include preparatory

Page 59: Model Bill

work, labours to backs, beds and joints, templets, mortices for bolts etc and for hoisting and setting in position, bedding, jointing and pointing, casing and protecting from injury and cleaning down at completion

Descriptions of recessed pointing to stonework shall be deemed to include square recessed, hollow recessed, weathered pointing, etc

SLATE PAVING

MARBLE PAVING

GRANITE PAVING

? slate paving with polished finish

? marble paving with polished finish

? granite paving with flamed non-slip finish

Paving to floors of ?mm thick slabs not exceeding 0,5m2 on face with m2 bedding ?mm thick

Ditto but exceeding ?m2 and not exceeding ?m on face m2

Fair circular cutting. m

Paving to floors to falls of ?mm thick slabs not exceeding 0,5m2 on m2 face with bedding average ?mm thick

Ditto but each slab with one edge cut circular and three edges cut m2 raking

Ditto but each slab with two edges cut circular and two edges cut m2 raking

Fair circular cutting. m

Fair edge to ?mm thick paving m

Fair edge to ?mm thick paving circular on plan to ?m radius m

? x ?mm Risers in lengths to match paving with bedding ?mm thick m

? x ?mm Risers in lengths to match paving with bedding ?mm thick m circular on plan to ?mm radius in short straight slabs

Page 60: Model Bill

? x ?mm Treads in lengths to match paving with bedding ?mm thick m

? x ?mm Notch in ?mm thick paving No

Hole for pipe not exceeding ?mm diameter in ?mm thick paving No

Hole for pipe exceeding ?mm and not exceeding ?mm diameter in No ?mm thick paving

? x ? x ?mm Cover slab with ?mm diameter hole for pipe No

SLATE WALL LININGS ETC

MARBLE WALL LININGS ETC

GRANITE WALL LININGS ETC

Wall linings are as indicated on architect's drawings numbered ....., ....., ..... and ..... annexed to these bills of quantities/accompanying these bills of quantities for tender purposes Wall linings are to be fixed with phosphor bronze rods, expanding bolts and galvanised iron brackets as indicated on architect's drawing No .....

? slate wall linings with polished finish

? marble wall linings with polished finish

? granite wall linings with polished finish

? granite wall linings with bush hammered finish

? granite wall linings with ? finish

?mm Thick in rectangular stones not exceeding 0,5m2 on face m2

?mm Thick in rectangular stones exceeding ?m2 and not exceeding m2 ?m2 on face

Fair edge to ?mm thick linings m

Fair edge to ?mm thick linings circular on plan to ?m radius m

? x ?mm Rebate m

?mm Radius rounded angle m

?mm Radius sunk rounded angle m

? x ?mm Throat m

? x ?mm Notch in ?mm thick lining No

Hole for pipe not exceeding ?mm diameter in ?mm thick lining No

Page 61: Model Bill

Hole for pipe exceeding ?mm and not exceeding ?mm diameter in No ?mm thick lining

? x ? x ?mm High extreme keystone to flat arch with sides sloping to No ?mm wide at bottom finished on face and soffit

? granite with ? finish

? x ?mm Rebated door frame in suitable butt jointed lengths bedded m against and bolted to brickwork or concrete

Extra for mitred joint between head and stiles No

?mm Diameter hole through ?mm thick frame for bolt No

?mm Diameter hole ?mm deep for hinge fixing No

? x ? x ?mm Deep sinking for hinge plate No

SUNDRIES

?mm Wide turning piece to lintels etc m

?mm Wide centre to segmental arch ?mm span No

BILL ?

WATERPROOFING

SUPPLEMENTARY PREAMBLES

Waterproofing

Waterproofing of roofs, basements, etc shall be laid under a ten year guarantee. Waterproofing to roofs shall be laid to even falls to outlets etc with necessary ridges, hips and valleys. Descriptions of sheet or membrane waterproofing shall be deemed to include additional labour to turn-ups and turn-downs

DAMP-PROOFING OF WALLS AND FLOORS

One layer of type FV damp proof course

One layer of 375 micron "Consol Plastics Brikgrip DPC" embossed damp proof course

In walls m2

One layer of 250 micron "Consol Plastics Gunplas Black" waterproof sheeting sealed at laps with "Gunplas Pressure Sensitive Tape"

Page 62: Model Bill

One layer of 250 micron "Consol Plastics Gunplas USB Green" waterproof sheeting sealed at laps with "Gunplas Pressure Sensitive Tape"

One layer of 375 micron "Consol Plastics Hyperlastic Orange" waterproof sheeting sealed at laps with "Superstik" tape

One layer of ? micron "Consol Plastics Hyperlastic Orange" waterproof sheeting sealed at laps with "Superstik" tape

Under surface beds m2

Vertically between walls m2

Two coats "Brixeal" bitumen emulsion waterproof coating

Two coats "Flintkote Type 5" bitumen emulsion waterproof coating

Primer and two coats "Bostik M6" rubber bitumen emulsion paint

Primer three coats "Bostik M6" rubber bitumen emulsion paint and one coat "Alupaste M70" aluminium coating

On concrete floors m2

On concrete walls, columns and beams m2

On concrete walls and columns in foundations (Provisional) m2

On brick walls m2

On bagged brick walls m2

WATERPROOFING TO ROOFS, BASEMENTS, ETC

Five coat "Acrylastic" fibre reinforced heavy duty maintenance free acrylic waterproofing

Three layers type 60 roofing felt sealed with hot bitumen compound

Bondglass flexible reinforced waterproofing

One layer "Bituthene 3000" waterproofing

4mm "Derbigum SP" waterproofing

4mm "Derbigum SP" fully bonded waterproofing

4mm "Derbigum SP" waterproofing covered with type 40 bituminous fibreglass felt loose laid protection layer with coarse

Page 63: Model Bill

building sand blinding

On flat floors m2

On sloping floors m2

On balcony floors m2

On shower floors m2

On flat roofs m2

On sloping roofs with ? degrees pitch. m2

On walls m2

On tops and sides of inverted beams m2

On bottoms and sides of floor ducts, channels, etc m2

On bottoms and sides of box gutters m2

On bottoms and sides of planter boxes m2

On internal surfaces of ? x ? x ?mm deep sump, catchpit, etc No

Sealing edges to brickwork or concrete m

Sealing edges to ? m

Sealing edges to brickwork or concrete including trowelled mastic m bead

Flashing strip ?mm girth at turn-ups including sealing top edge into m groove with mastic

Additional membrane ?mm girth at internal and external angles m

Additional membrane ?mm girth at internal and external angles m circular on plan including forming darts as necessary

Additional membrane ?mm girth at turn-ups including flashing strip m ?mm girth and sealing top edge into groove with mastic

Additional membrane at ?mm diameter outlet No

Page 64: Model Bill

Collar around pipe not exceeding 100mm internal diameter No

Two layers "Trinico" mastic asphalt waterproofing

Two layers "?" mastic asphalt waterproofing

Two layers "?" mastic asphalt trafficable waterproofing with coarse building sand or fine stone chips evenly spread and well rolled in

?mm Thick on flat roofs including "Kraftex" grade 22 paper m2 underlayer with 30mm laps

?mm Thick on sloping roofs with ? degrees pitch. m2

?mm Thick on walls m2

?mm Thick on walls circular exceeding 300mm radius m2

?mm Thick on walls circular not exceeding 300mm radius m2

?mm Thick on tops and sides of inverted beams m2

?mm Thick on bottoms and sides of floor ducts, channels, etc m2

?mm Thick on bottoms and sides of box gutters m2

?mm Thick on internal surfaces of ? x ? x ?mm deep sump, catchpit, No etc

?mm Skirting average ?mm high with ? x ?mm triangular fillet at m bottom

?mm Skirting average ?mm high with ? x ?mm triangular fillet at m bottom circular exceeding 300mm radius

?mm Skirting average ?mm high with ? x ?mm triangular fillet at m bottom circular not exceeding 300mm radius

?mm Skirting average ?mm high with top turned into groove (groove m elsewhere) and ? x ?mm triangular fillet at bottom

?mm Turn-down average ?mm high m

30 x 30mm Triangular fillet m

? x ? Triangular fillet m

PROTECTIVE STONE DRESSING

Page 65: Model Bill

?mm Crushed stone dressing evenly spread with larger stones around outlets

?mm River stone pebble dressing evenly spread with larger stones around outlets

?mm Thick on waterproofing to flat roofs m2

PROTECTIVE ROOFING PAINT

Two coats "Silvakote" bituminous aluminium paint

Two coats bituminous aluminium paint

Two coats "Plycol Colortop" heavy duty acrylic emulsion paint

Two coats heavy duty acrylic emulsion paint

On waterproofing to roofs m2

On waterproofing to box gutters m2

PROTECTIVE PAVING

305 x 305 x 9,5mm "Everite Roof Decking" fibre-cement tile paving with 2mm wide continuous joints in both directions bedded and jointed in hot bitumen including prime coat to backs of tiles

On waterproofing to flat roofs m2

On waterproofing to turn-ups not exceeding 300mm high m

WATERSTOPS

S? PVC waterstops cast into concrete

? Rubber waterstops cast into concrete

?mm "?" waterstops m

Fused angle intersection to ?mm waterstops. No

Fused T-intersection to ?mm waterstops. No

JOINT SEALANTS ETC

Compriband bitumen impregnated foam plastic joint sealing strips

Page 66: Model Bill

? x ?mm In joints between frames and walls m

? x ?mm In expansion joints m

? mastic sealing compound including backing cord, bond breaker, primer, etc

? two-part grey polysulphide sealing compound including backing cord, bond breaker, primer, etc

? silicone sealing compound including backing cord, bond breaker, primer, etc

6 x 10mm In saw cut joints in floors m

? x ?mm In saw cut joints in floors m

? x ?mm In expansion joints in floors m

? x ?mm In vertical expansion joints m

? x ?mm In expansion joints in soffits m

? x ?mm In expansion joints in floors including raking out expansion m joint filler as necessary

? x ?mm In vertical expansion joints including raking out expansion m joint filler as necessary

? x ?mm In expansion joints in soffits including raking out expansion m joint filler as necessary

BILL ?

ROOF COVERINGS ETC

SLATES

Roof slates single thickness? x ?mm Silver Blue/West Country/Multi Coloured slates laid in single thickness with a headlap of 90mm on a lapped underlay of type ? bituminous roofing felt faced with 0,1mm aluminium foil over half its width with 150mmheadlaps and slates top nailed through underlay with galvanised/copper clout nails to ? x ?mm sawn softwood battens at ?mm centres

? x ?mm Silver Blue/West Country/Multi Coloured slates laid in double thickness with a headlap of 75mm and centre nailed with galvanised/copper clout nails to ? x ?mm sawn softwood battens at ?mm centres

610 x 406 x 5/7,5mm "Everite" nutec-cement/fibre-cement plain/textured slates nailed with galvanised/copper clout nails to ? x ?mm sawn softwood battens at 250mm centres and fastened

Page 67: Model Bill

together with copper disc rivets

Roof covering with pitch not exceeding 25 degrees m2

Roof covering circular on elevation along the fall to ?m radius m2

Roof covering with pitch not exceeding 25 degrees circular on m2 elevation across the fall to ?m radius

Roof covering with ? degrees pitch m2

Roof covering to conical shape with ? degrees pitch and radius m2 varying from ? to ?m including cutting slates to wedge shape

Side cladding to gables etc m2

Side cladding to gables etc circular on plan to ?m radius m2

Soffit cladding to overhangs etc. m2

Roof covering and side and soffit claddings to dormers, turrets, etc m2

Extra on roof covering for double course at eaves including fixing m clips and ? x ?mm sawn softwood tilting fillet

Circular cutting m

Close cut and mitred ridge including type ? bituminous roofing felt m soakers and additional battens

Close cut and mitred hip including type ? bituminous roofing felt m soakers and additional battens

Close cut and mitred valley including type ? bituminous roofing felt m soakers and additional battens

Close cut and mitred vertical angle including type ? bituminous m roofing felt soakers and additional battens

TILES

User note:

The fixing recommendations of the manufacturer of the tiles used for the specific region and/or situation are to be incorporated as supplementary preambles

Page 68: Model Bill

? x ?mm "?" concrete/terra cotta tiles nailed with non-corrosive tile nails to ? x ?mm sawn softwood battens at ?mm centres

? x ?mm "?" concrete/terra cotta tiles laid on an underlay of ? micron "?" plastic sheeting with 75mm lapped and sealed joints and nailed through underlay with non-corrosive tile nails and/or fixed with suitable non-corrosive clips as required nailed through underlay to ? x ?mm sawn softwood battens at ?mm centres

Roof covering with pitch not exceeding 25 degrees m2

Roof covering with ? degrees pitch m2

Side cladding to gables etc m2

Soffit cladding to overhangs etc. m2

Roof covering and site cladding to dormers, turrets, etc. m2

Extra on roof covering for double course at eaves including ? x ?mm m sawn softwood tilting fillet.

Circular cutting m

Ridge tiles to match roofing tiles bedded and pointed in 1:3 cement m mortar tinted to match tile colour

Hip tiles to match roofing tiles bedded and pointed in 1:3 cement m mortar tinted to match tile colour

Verge capping tiles to match roofing tiles fixed with non-corrosive m fixing accessories

Purpose made tile to end of ridge bedded and pointed in 1:3 cement No mortar tinted to match tile colour

Purpose made tile to 3-way intersection of ridge with hips bedded and No pointed in 1:3 cement mortar tinted to match tile colour

SHINGLES

User note:

Page 69: Model Bill

Western red cedar is the wood normally used for making shingles and is imported. Other types of wood such as oak, elm, pine and teak have apparently not given satisfactory results. The nominal length of western red cedar shingles are400mm and the widths vary from 75 to 300mm

The minimum pitch recommended for a 125mm gauge (i.e. 125mm length exposed to the weather) is 30 degrees, but if the gauge is decreased the pitch may be reduced (e.g. 20 degrees with a 95mm gauge)

Close boarding and underlays are not necessary to prevent water penetration as the shingles lie closely upon one another, also ensuring a draughtproof roof

Western red cedar shingles in approximately 400mm lengths and widths varying from 75 to 250mm laid with 125mm gauge and minimum side laps of 38mm and nailed with non-corrosive clout nails to ? x ?mm sawn softwood battens at 125mm centres spiked on

Roof covering with pitch not exceeding 25 degrees m2

Roof covering with ? degrees pitch m2

Side cladding to gables etc m2

Soffit cladding to overhangs etc. m2

Roof covering and side and soffit claddings to dormers, turrets, etc m2

Extra on roof covering for double course at eaves including ? x ?mm m sawn softwood tilting fillet

Circular cutting m

Close cut and mitred hip including ?mm thick galvanised sheet m iron/sheet copper/sheet aluminium soakers and additional battens

Close cut and mitred valley including ?mm thick galvanised sheet m iron/sheet copper/sheet aluminium soakers and additional battens

Page 70: Model Bill

Saddle ridge of narrow width shingles laid with top ends lapped m alternately and minimum side laps of 38mm and nailed with non-corrosive clout nails

THATCH

User note:

Grass in the Transvaal area suitable for thatch is the hyparthenia species and is obtainable in lengths varying from 760 to 1020mm

The minimum density to which the above mentioned grass should be compacted is 30kg/m/150mm thickness

The fire blanket usually consists of an interlay or an underlay of "Sisalation 420" or similar sheeting

?mm Thick thatch of hand cut grass of the ? species in lengths varying from ? to ?mm laid in bundles of suitable size, compacted to a minimum density of ?kg/m/150mm thickness and fixed by means of suitable fixing rods interlaced through and over the bundles at not exceeding 600mm centres and secured with tarred twine to eucalyptus battens CCA treated in accordance with SABS 457, varying in diameter from 20 to 40mm, spaced generally at maximum 300mm centres and at closer centres nearer to eaves

?mm Thick thatch of hand cut grass of the ? species in lengths varying from ? to ?mm laid in bundles of suitable size, compacted to a minimum density of ?kg/m/150mm thickness with a fire retardent interlay of "?" heavy industrial grade aluminium based sheeting woven in between the thatch and lapped ?mm at joints and grass fixed by means of suitable fixing rods interlaced through and over the bundles at not exceeding 600mm centres and secured through interlay with tarred twine to eucalyptus battens CCA treated in accordance with SABS 457, varying in diameter from 20 to 40mm, spaced generally at maximum 300mm centres and at closer centres nearer to eaves

Covering to general roof slopes m2

Covering to general roof slopes including spreadlayer to exposed m2 soffit

Covering to dormers, turrets, etc m2

Ridge formed by extending covering above ridge level on the one roof m slope, bending over and down on the opposite slope and fixing and

Page 71: Model Bill

securing as described for roof covering and repeating the process on the other roof slope including covering with galvanised wire birdnetting 900mm girth and additional fixing rods

Purpose made continuous glass fibre ridge capping of not less than m 1,5mm thick material 1300mm girth in suitable lengths securely fixed to thatch with 75mm wide lapped and sealed heading joints including grass filling under

Extra over ridge capping for purpose made angle piece No

Extra over ridge capping for purpose made curved returned end piece No

PROFILED FIBRE-CEMENT SHEETING AND ACCESSORIES

User note:

Supplementary preambles in connection with fixing of sheeting and accessories and laps are to be inserted when the Model Preambles for Trades (or other preambles not covering the fixing of sheeting and accessories and laps) are used

When the pitch of the roof is less than 9 degrees or if dustproofing is required then the description of roof covering "with side and end laps sealed" is to be used

Everite Big six sheeting fixed to timber/steel purlins or rails

? sheeting fixed to timber/steel purlins or rails

Everite Big six sheeting with "Colorbrite" finish on one side fixed to timber/steel purlins or rails and accessories with "Colorbrite" finish on one side

? profiled fibre-cement sheeting with "?" finish on one side/both sides fixed to timber/steel purlins or rails and accessories with "?" finish on one side

Roof covering with pitch not exceeding 25 degrees m2

Roof covering with ? degrees pitch m2

Roof covering with pitch not exceeding 25 degrees with side and end m2 laps sealed with 12 x 25mm closed cell impregnated polyurethane foam strips

Page 72: Model Bill

Side cladding m2

Soffit cladding. m2

Extra over roof covering/side cladding/soffit cladding for ?mm m2 semi-opaque ?% light transmission "?" translucent sheet panel

Extra over roof covering for soaker flange sheet suitable for "?" No ventilator with throat size ? x ?mm

Circular cutting m

Side apron flashing m

End apron flashing m

Plain fixed angle ridge/hip capping m

Plain adjustable ridge/hip capping m

Fixed angle wide profile ridge sheets m

Ridge sheets ?mm girth m

Fixed angle wide profile curved ridge sheets ?mm girth m

Close fitting adjustable ridge capping m

Fixed angle sawtooth ridge capping m

Adjustable sawtooth ridge capping m

Birdproofing m

Eaves fillers m

Straight sill flashing m

U-flashing m

Hip end cap No

Ridge end cap No

Junction of ridge with two hip cappings No

PROFILED METAL SHEETING AND ACCESSORIES

User note:

Page 73: Model Bill

Supplementary preambles in connection with fixing of sheeting and accessories and laps are to be inserted when the Model Preambles for Trades (or other preambles not covering the fixing of sheeting and accessories and laps) are used

When the pitch of troughed roof covering is less than 5 degrees or if dustproofing is required then the description of roof coverings "with side laps sealed" is to be used

Where roof coverings are fixed on top of rigid board insulation to purlins etc descriptions of roof coverings are to include therefore

Note that sheeting is also available in corten steel, stainless steel, copper and aluminium

?mm Corrugated ? spelter galvanised sheet steel fixed to timber/steel purlins or rails

?mm Corrugated ? spelter galvanised sheet steel with "?" finish on one side fixed to timber/steel purlins or rails

?mm "?" ? spelter embossed galvanised troughed sheet steel in single lengths fixed to timber/steel purlins or rails and ?mm embossed galvanised sheet steel accessories

?mm "?" ? spelter embossed galvanised troughed sheet steel with "?" finish on one side in single lengths fixed to timber/steel purlins or rails and ?mm embossed galvanised sheet steel accessories with "?" finish on one side

?mm "?" ? spelter embossed galvanised troughed sheet steel with "?" finish on both sides in single lengths fixed to timber/steel purlins or rails and ?mm embossed galvanised sheet steel accessories with "?" finish on one side

Roof covering with pitch not exceeding 25 degrees m2

Roof covering with ? degrees pitch m2

Roof covering with pitch not exceeding 25 degrees with side laps m2 seam stitched

Page 74: Model Bill

Roof covering with pitch not exceeding 25 degrees with side laps m2 sealed with 6 x 20mm closed cell impregnated polyurethane strips

Roof covering with pitch not exceeding 25 degrees with side laps m2 sealed with 6 x 20mm closed cell impregnated polyurethane strips and seam stitched

Roof covering circular on elevation to ?m radius m2

Roof covering circular on elevation to ?m radius with side laps sealed m2 with 6 x 20mm closed cell impregnated polyurethane strips

Side cladding m2

Side cladding circular on plan to ?m radius m2

Soffit cladding. m2

Roof covering and side and soffit claddings to dormers, turrets, etc m2

Extra over roof covering/side cladding/ soffit cladding for ?mm m2 semi-opaque ?% light transmission "?" translucent panel

Circular cutting m

Extra over roof covering for ? degrees crank to form ridge m

Extra over roof covering for ? degrees bullnose to ?mm radius at edge m

Extra over roof covering for ? degrees curved turn-up to ?mm radius m at edge

Rolled edge at verge m

Ridge capping ?mm girth m

Hip capping ?mm girth m

Side wall flashing ?mm girth m

Page 75: Model Bill

Head wall flashing ?mm girth m

Gable trim ?mm girth m

Apex flashing ?mm girth m

Corner trim ?mm girth m

Apron flashing ?mm girth m

Z-profile flashing ?mm girth m

Drip flashing ?mm girth m

Sill flashing ?mm girth m

Jamb flashing ?mm girth m

Narrow and broad flute closers ?mm girth m

Narrow and broad flute closers ?mm girth raking at valleys or hips m

Moulded narrow and broad rib polyethelene filler blocks m

Moulded narrow and broad rib polyethelene filler blocks raking at m valleys or hips

?mm "?" ? spelter galvanised ribbed sheet steel in single lengths fixed to timber/steel purlins or rails and ?mm galvanised sheet steel accessories

?mm "?" ? spelter galvanised ribbed sheet steel with "?" finish on one side in single lengths fixed to timber/steel purlins or rails and ?mm galvanised sheet steel accessories with "?" finish on one side

?mm "?" ? spelter galvanised ribbed sheet steel with "?" finish on both sides in single lengths fixed to timber/steel purlins or rails and ?mm galvanised sheet steel accessories with "?" finish on one side

Roof covering with pitch not exceeding 25 degrees m2

Roof covering with ? degrees pitch m2

Side cladding m2

Soffit cladding. m2

Roof covering and side and soffit claddings to dormers, turrets, etc m2

Page 76: Model Bill

Extra over roof covering/side cladding/soffit cladding for ?mm m2 semi-opaque ?% light transmission "?" translucent sheet panel

Circular cutting m

Extra over roof covering for ? degrees crank to form ridge including m rib caps and sealing

Extra over roof covering for ? degrees bullnose to ?mm radius at edge m

Extra over roof covering for ? degrees curved turn-up to ?mm radius m at edge

Ridge covering ?mm girth m

Hip covering ?mm girth m

Side wall flashing ?mm girth m

Head wall flashing ?mm girth m

Serrated top end closer ?mm girth m

? x ?mm Standard box gutter fixed to roof sheeting with clips m

Extra over ? x ?mm box gutter for stopped end No

Extra over ? x ?mm box gutter for angle No

Extra over ? x ?mm box gutter for outlet with nozzle for and joint to No ?mm diameter rainwater pipe including domical grating

Extra over ? x ?mm box gutter for outlet with nozzle for and joint to m ? x ?mm rainwater pipe including dominical grating

?mm "?" profile semi-opaque ?% light transmission "?" translucent sheeting with ?mm end laps fixed to timber/steel purlins or rails

?mm "?" profile semi-opaque ?% light transmission "?" translucent sheeting with ?mm sealed end laps and side laps seam stitched at 500mm centres fixed to timber/steel purlins or rails

Roof covering with pitch not exceeding 25 degrees m2

Page 77: Model Bill

Roof covering with ? degrees pitch m2

Side cladding m2

Circular cutting m

ROOF VENTILATORS

Everite

Product No. 560-235 fibre-cement plain wing continuous ridge m ventilator to ? degrees angle and with base wing ?mm long fixed through "?" roof sheeting to steel purlins including watertight heading joints, necessary sealing strips, fixing accessories, etc

Closed end piece to plain wing continuous ridge ventilator No

Vent-air Product No. 560-270 fibre-cement ventilator fixed on No soaker flange sheet (soaker flange sheet elsewhere) including sealing strips, fixing accessories, etc

Robertson

QPM 615 galvanised sheet steel multi-purpose ventilator 1,83m No long fixed through "?" roof sheeting to steel purlins including flashings, closers, sealing strips, etc

ROOF AND WALL INSULATION

Sisalation 420 heavy industrial grade aluminium foil based insulation

Insulation laid taut over purlins (at approximately ?mm centres) and m2 fixed concurrent with roof covering including galvanised steel straining wires

Sisalation 410 housing grade glass fibre reinforced aluminium foil bonded insulation

Insulation laid taut over rafters (at approximately ?mm centres) and m2 fixed concurrent with tiling battens, purlins, etc

Fibreglass reinforced aluminium foil faced resin bonded glass fibre flexible building insulation

?mm Insulation laid taut over purlins (at approximately ?mm centres) m2 and fixed concurrent with roof covering

?mm Insulation laid taut over purlins (at approximately ?mm centres) m2 and fixed concurrent with roof covering including plastic covered galvanised steel straining wires

Page 78: Model Bill

Structaboard aluminium foil faced polyisocyanurate foam core rigid board insulation

Structaboard aluminium foil faced polyisocyanurate foam core rigid board insulation with clear lacquer finish on one side and white lacquer finish on other side

?mm Insulation boards in 1200mm widths with longitudinal flap m2 joints laid over purlins (at approximately ?mm centres) and fixed concurrent with roof covering including holes through boards etc

?mm Insulation boards in 1200mm widths with L24161 H-section m2 aluminium bearers at longitudinal joints laid over purlins (at approximately ?mm centres) and fixed concurrent with roof covering including holes through boards etc

?mm Insulation boards in 1200mm widths with L24161 H-section m2 aluminium bearers at longitudinal joints placed vertically over bearers etc (at approximately ?mm centres) and fixed concurrent with vertical cladding including holes through boards etc

FLAT SHEET METAL

0,6mm Galvanised sheet iron/0,56mm Grade 004 HC copper sheet/1,2mm Aluminium sheet of 3004/H4 alloy laid on boarding and sheets jointed in the direction of the flow by double-lock welts into standing seams (?mm high, overcloak ?mm, undercloak ?mm) and across the fall by double-lock welts (?mm wide, overcloak ?mm, undercloak ?mm) and attached to roof along standing seams with clips ?mm wide and ?mm girth cut from sheeting material, each double nailed to boarding with non-corrosive clout nails, bent up into seam and folded concurrent with sheeting in forming the welt

0,6mm Galvanised sheet iron/0,56mm Grade 004 HC copper sheet/1,2mm Aluminium sheet of 3004/H4 alloy laid on boarding with an underlay of type ? bituminous roofing felt, butt jointed and fixed with non-corrosive clout nails and sheets jointed in the direction of the flow by double-lock welts into standing seams (?mm high, overcloak ?mm, undercloak ?mm) and across the fall by double-lock welts (?mm wide, overcloak ?mm, undercloak ?mm) and attached to roof along standing seams with clips ?mm wide and ?mm girth cut from sheeting material, each double nailed through underlay to boarding with non-corrosive clout nails, bent up into seam and folded concurrent with sheeting in forming the welt

Roof covering with pitch not exceeding 25 degrees m2

Roof covering with ? degrees pitch m2

Page 79: Model Bill

Roof covering circular on elevation along the fall to ?m radius m2

Roof covering with pitch not exceeding 25 degrees circular on m2 elevation across the fall to ?m radius

Side cladding to gables etc m2

Roof covering and side and soffit claddings to dormers, turrets, etc m2

Circular cutting m

SHEET METAL FLASHINGS, LININGS, COPINGS, ETC

?mm Galvanised sheet iron

?mm Galvanised sheet iron with "?" finish on one side

0,6mm "Saftal" aluminium sheet

Flashings m2

Stepped cover flashings m2

Stepped cover flashings to roof pitches exceeding 25 degrees m2

Soakers m2

Linings to valleys with riveted and soldered joints m2

Lining to box gutters with riveted and soldered joints m2

Copings with riveted and soldered joints attached with suitable clips m2 at 500mm centres along both edges, riveted to coping and plugged to brickwork or concrete

Antguards m2

Circular cutting m

Apron flashing ?mm girth m

Cover flashing ?mm girth m

Coping ?mm girth attached with suitable clips at 500mm centres m along both edges, riveted to coping and plugged to brickwork or concrete

Page 80: Model Bill

BILL ?

CARPENTRY AND JOINERY

SUPPLEMENTARY PREAMBLES

Particle board:

Particle board shall comply with the following specifications:

a) SABS 1300 Particle board: exterior and flooring type

b) SABS 1301 Particle board: interior type

Joinery:

Descriptions of frames shall be deemed to include frames, transomes, mullions, rails, etc

Descriptions of hardwood joinery shall be deemed to include pelleting of bolt holes

Fixing

Items described as "nailed" shall be deemed to be fixed with hardened steel nails or shot pins to brickwork or concrete

Decorative laminate finish:

Laminate finish shall be glued under pressure. Edge strips shall be butt jointed at junctions with adjacent similar finish

ROOFS ETC

Plate nailed timber roof truss construction

The following is applicable in respect of roof trusses:

Trusses are at maximum ?mm centres

Page 81: Model Bill

Roof covering is ? on purlins/battens Ceilings are ?mm sheeting (with skimming?) on ? x ?mm brandering The references given in the descriptions are to the respective types of trusses detailed on the architect's drawings numbered ..... annexed to these bills of quantities/accompanying these bills of quantities for tender purposes

The dimensions in the descriptions of the trusses are nominal and actual measurements are to be obtained from the architect and/or the site before design or fabrication commences

Sawn softwood

? x ?mm Wall plates m

? x ?mm Longitudinal bracing m

? x ?mm Cross bracing m

? x ?mm Purlins m

Truss type ?, ? x ?mm high overall No

Truss type ?, ? x ?mm high overall with ?mm eaves overhang No projection on one (both) side(s)

Trusses in double hip set type ? ? x ? x ?mm high overall including No jack rafters, permanent bracing, etc

Trusses in hip and valley set type ? ? x ? x ?mm high overall including No jack rafters, permanent bracing, etc

Trusses in double valley set type ? ? x ? x ?mm high overall including No jack rafters, permanent bracing, etc

Roof construction to double pitched roof with two hipped ends ? x ?m No and ?mm high overall including wall plates, trusses, jack rafters, permanent bracing and ? x ?mm purlins/battens at centres for roof covering

Sawn softwood grade ?

Wrought softwood grade ?

?mm Gutter boarding m2

?mm Boarding to tank stands m2

?mm Tongued and grooved roof boarding in ?mm widths m2

Raking cutting to ?mm boarding m

Circular cutting to ?mm boarding m

Page 82: Model Bill

? x ?mm Wall plates m

? x ?mm Wall plates bolted m

? x ?mm Bracing m

? x ?mm Hangers m

? x ?mm Runners m

? x ?mm Trimmers m

? x ?mm Sprockets m

? x ?mm Ceiling joists in lengths not exceeding 2,4m m

? x ?mm Ceiling joists in lengths exceeding ?m and not exceeding ?m m

? x ?mm Rafters in lengths not exceeding 2,4m m

? x ?mm Rafters in lengths exceeding 2,4m and not exceeding 3,9m m

? x ?mm Rafters in lengths exceeding 3,9m and not exceeding 6,6m m

? x ?mm Rafters in lengths exceeding 6,6m m

? x ?mm Bearers bolted m

? x ?mm Bearers in lengths exceeding 2,4m and not exceeding 3,9m m

? x ?mm Bearers in lengths exceeding 3,9m and not exceeding 6,6m m

? x ?mm Bearers in lengths exceeding 6,6m m

? x ?mm Bolted roof truss members in lengths not exceeding 2,4m m

? x ?mm Bolted roof truss members in lengths exceeding 2,4m and m not exceeding 3,9m

? x ?mm Bolted roof truss members in lengths exceeding 3,9m and m not exceeding 6,6m

? x ?mm Bolted roof truss members in lengths exceeding 6,6m m

? x ?mm Valley boarding m

? x ?mm Gangboarding m

? x ?mm Battens for ? roof covering m

? x ?mm Tilting fillets m

Page 83: Model Bill

? x ?mm Cross battens at hips, valleys, etc m

? x ?mm Purlins m

? x ?mm Purlins bolted m

? x ?mm Splayed purlins m

? x ?mm Blocking piece ?mm long No

? laminated timber

? wrought laminated timber

? wrought laminated timber (architectural finish)

? x ?mm Bearers bolted m

? x ?mm Beams, pergola beams, etc bolted m

? x ?mm Arched beam ?mm girth circular across ?mm depth to ?mm No inner radius bolted

Sundries

Wrought faces on sawn timbers m2

Two coats creosote on sawn timbers m2

?mm Long wrought end to ? x ?mm sawn timber No

?mm Long wrought and shaped end to ? x ?mm sawn timber No

?mm Diameter "Bulldog" toothed ring timber connector No

?mm Diameter "Teco" split ring timber connector including grooves No in timber

?mm Diameter galvanised wire tie ?mm girth wrapped around rafter No and purlin with ends tied together

? x ?mm Galvanised hoop iron roof tie ?m girth with each end fixed No to timber

EAVES, VERGES, ETC

Sawn softwood

Wrought softwood

Wrought meranti

Eaves soffit covering of ? x ?mm slats at ?mm centres m2

Page 84: Model Bill

Verge soffit covering of ? x ?mm slats at ?mm centres m2

Eaves soffit covering of ?mm tongued and grooved boarding in ?mm m2 widths

Verge soffit covering of ?mm tongued and grooved boarding in ?mm m2 widths

? x ?mm Branders m

? x ?mm Branders wrought on one face m

? x ?mm Bearers m

? x ?mm Hangers m

?mm Quadrant beads m

? x ?mm Beads m

?mm Half round cover strips m

? x ?mm Cover strips m

? x ?mm Fascias and barge boards m

Everite FC77 pressed fibre-cement

Everite Flexit pressed nutec-cement

Eaves soffit covering ?mm wide of ?mm thick sheets (branders m2 elsewhere)

Eaves soffit covering ?mm wide of ?mm thick sheets including ? x m2 ?mm sawn softwood brandering along edges, along centre and at ?mm centres across sheets

Verge soffit covering ?mm wide of ?mm thick sheets (branders m2 elsewhere)

Verge soffit covering ?mm wide of ?mm thick sheets including ? x m2 ?mm sawn softwood brandering along edges and at ?mm centres across sheets

? x ?mm Cover strips m

? x ?mm Fascias and barge boards including galvanised steel m H-profile jointing strips

FLOORS ETC

Sawn softwood

? x ?mm Battens wired to concrete (wire ties elsewhere) m

Page 85: Model Bill

? x ?mm Wall plates m

? x ?mm Floor joists in lengths not exceeding 2,4m m

? x ?mm Floor joists in lengths exceeding ?m and not exceeding ?m m

? x ?mm Bearers in lengths exceeding ?m and not exceeding ?m m

Wrought ?

Flooring of ?mm tongued and grooved boarding in ?mm widths m2

Raking cutting to ?mm boarding m

Circular cutting to ?mm boarding m

? x ?mm Risers with rebated top edge let into and including groove in m treads

? x ?mm Treads with rounded front edge m

Extra over floor boarding for ? x ?mm trapdoor with ? x ?mm No framing and ? x ?mm rebated trimmers all round

Wire ties

?mm Diameter galvanised wire tie ?mm girth bent double, embedded No in concrete and bound around floor battens including saw cuts

SKIRTINGS

Wrought softwood

Wrought meranti

Wrought ?

? x ?mm Skirting m

? x ?mm Skirting nailed m

? x ?mm Skirting plugged m

? x ?mm Skirting stepped over treads and risers nailed m

? x ?mm Skirting stepped over treads and risers plugged m

?mm Raking skirting ?mm high extreme with bottom edge stepped m over treads and risers nailed

?mm Raking skirting ?mm high extreme with bottom edge stepped m over treads and risers plugged

Page 86: Model Bill

? x ?mm Skirting including ?mm quadrant bead nailed m

? x ?mm Skirting including ?mm quadrant bead plugged m

DOORS ETC

Wrought softwood doors

Wrought softwood doors hung to steel frames

Wrought meranti doors

Wrought meranti doors hung to steel frames

Wrought ? doors

Wrought ? doors hung to steel frames

?mm Framed fanlight ? x ?mm high of ?mm frame in single pane No rebated all round including ? x ?mm glazing beads on one side

?mm Framed fanlight ? x ?mm high of ?mm frame and mullion in two No panes rebated all round including ? x ?mm glazing beads on one side

?mm Framed door ? x ?mm high of ?mm top rail and stiles and ?mm No bottom rail in single pane rebated all round including ? x ?mm glazing beads on one side

?mm Framed door ? x ?mm high of ?mm top rail, middle rail and No stiles and ?mm bottom rail in two panes rebated all round including ? x ?mm glazing beads on one side

?mm Framed double door ? x ?mm high with ? (flush/rebated) No meeting stiles, each leaf of ?mm top rail and stiles and ?mm bottom rail in single pane rebated all round including ? x ?mm glazing beads on one side

?mm Framed batten door ? x ?mm high of ? x ?mm top rail and stiles, No ? x ?mm middle ledge and ? x ?mm bottom ledge filled in with ?mm V-jointed one side boarding

?mm Framed batten door ? x ?mm high of ? x ?mm top rail and stiles, No ? x ?mm middle ledge and braces and ? x ?mm bottom ledge filled in with ?mm V-jointed one side boarding

?mm Framed batten door ? x ?mm high of ? x ?mm top rail and stiles, No ? x ?mm middle ledge and braces and ? x ?mm bottom rail filled in with ?mm V-jointed one side boarding

?mm Framed batten door ? x ?mm high of ? x ?mm top rail and stiles, No ? x ?mm middle ledge and braces and ? x ?mm bottom rail filled in with ?mm V-jointed one side boarding and covered on other side with ?mm plywood with veneer to match door let into and including rebates all round

Page 87: Model Bill

?mm Framed batten stable door ? x ?mm high with rebated meeting No rails, each leaf of ? x ?mm top rail, stiles and bottom rail and ? x ?mm brace filled in with ?mm V-jointed one side boarding

?mm Framed batten double door ? x ?mm high with ? (flush/rebated) No meeting stiles, each leaf of ? x ?mm top rail and stiles, ? x ?mm middle ledge and braces and ? x ?mm bottom ledge filled in with ?mm V-jointed one side boarding

?mm Slatted gate ? x ?mm high of ? x ?mm top, middle and bottom No ledges and ? x ?mm braces covered on one side with ? x ?mm vertical slats spaced at ?mm centres

? hollow core flush doors with 3,2mm standard hardboard covering on both sides hung to steel frames

? hollow core flush doors with commercial veneer

? hollow core flush doors with commercial veneer hung to slide

? hollow core flush doors with commercial veneer hung to steel frames

? hollow core flush doors with ? veneer

? hollow core flush doors with ? veneer hung to steel frames

? semi-solid flush doors with 3,2mm standard hardboard covering on both sides hung to steel frames

? semi-solid flush doors with ? veneer

? semi-solid flush doors with ? veneer hung to steel frames

? solid chipcore flush doors with ? veneer

? solid chipcore flush doors with ? veneer hung to steel frames

? solid chipcore external quality flush doors with ? veneer

? solid laminated flush doors with ? veneer

? solid laminated flush doors with ? veneer hung to steel frames

? solid laminated external quality flush doors with ? veneer

40mm Door ? x ?mm high No

Page 88: Model Bill

40mm Double door ? x ?mm high with ? (flush/rebated) meeting No edges

40mm Double door ? x ?mm high with rounded vertical edges No

40mm Door ? x ?mm high with ? x ?mm opening fitted with ? x ?mm No wrought ? glazing beads on both sides

40mm Double door ? x ?mm high with ? (flush/rebated) meeting No edges, each leaf with ? x ?mm opening fitted with ? x ?mm wrought ? glazing beads on both sides

Extra for ? x ?mm opening for metal louvre unit No

? doors

Type ? glazed door ? x ?mm high No

Type ? batten door ? x ?mm high No

Type ? panel door ? x ?mm high No

Bitcon Industries fire doors with ? veneer

Rubidor class ? fire door ? x ?mm high including pressed steel No frame for ? brick wall and preparing frame for door closer and lock

Rubidor class ? double fire door ? x ?mm high including pressed No steel frame for ? brick wall and preparing frame for door closers

Rubidor class ? double fire door ? x ?mm high, each leaf with 100 x No 300mm opening with clear fire-rated glass including pressed steel frame for ? brick wall and preparing frame for door closers

? folding doors including sliding gear, ironmongery, etc

Single door for opening ? x ?mm high fixed to timber No

Single door for opening ? x ?mm high fixed to brickwork or concrete No

Double door for opening ? x ?mm high fixed to timber No

Double door for opening ? x ?mm high fixed to brickwork or No concrete

? sliding doors including frames, sliding gear, ironmongery, 6mm clear toughened safety glass and standard sealer finish

(Type ?) door ? x ?mm high fixed to brickwork or concrete No

? wrought ? horizontal slatted spring balanced tip-up garage doors including ironmongery etc

Door for opening ? x ?mm high fixed to brickwork or concrete No

Page 89: Model Bill

WINDOWS

Wrought ? windows

? Wrought ? windows

Window type ? ? x ?mm high No

FRAMED FRAMES ETC

Wrought softwood

Wrought meranti

Wrought ?

? x ?mm Linings m

? x ?mm Linings plugged m

? x ?mm Rebated linings m

? x ?mm Rebated linings plugged m

? x ?mm Frames m

? x ?mm Frames plugged m

? x ?mm Frames bolted m

? x ?mm Rebated frames m

? x ?mm Rebated frames plugged m

? x ?mm Rebated frames bolted m

? x ?mm Rebated and splayed frames m

? x ?mm Rebated and splayed frames plugged m

? x ?mm Rebated and splayed frames bolted m

? x ?mm Twice rebated frames m

? x ?mm Twice rebated frames plugged m

? x ?mm Twice rebated frames bolted m

? x ?mm Twice rebated and splayed frames m

? x ?mm Twice rebated and splayed frames plugged m

? x ?mm Twice rebated and splayed frames bolted m

Page 90: Model Bill

? x ?mm Frames with one labour m

? x ?mm Frames with one labour plugged m

? x ?mm Frames with one labour bolted m

? x ?mm Frames with ? labours m

? x ?mm Frames with ? labours plugged m

? x ?mm Frames with ? labours bolted m

? x ?mm Splay rebated, angle rounded and grooved window sills m

? x ?mm Window sill with ? labours m

? x ?mm Frame with one labour for ? x ?mm high door No

? x ?mm Frame with ? labours for ? x ?mm high door No

BEADS, ARCHITRAVES, ETC

Wrought softwood

Wrought meranti

Wrought ?

? x ?mm Grounds m

? x ?mm Grounds nailed m

? x ?mm Grounds plugged m

? x ?mm Glazing beads m

? x ?mm Splayed glazing beads m

? x ?mm Twice angle rounded glazing beads m

? x ?mm Beads m

?mm Quadrant beads m

?mm Half round beads m

? x ?mm Architraves m

? x ?mm Architraves plugged m

? x ?mm Splayed and angle rounded architraves m

? x ?mm Splayed and angle rounded architraves plugged m

Page 91: Model Bill

? x ?mm Rebated, splayed and grooved weather boards including m grooves in doors

? x ?mm Rebated stiles bolted m

? x ?mm Window sills m

? x ?mm Window sills plugged m

? x ?mm Window sills with ? labours m

? x ?mm Window sills with ? labours plugged m

STAIRS ETC

Ten stairs 1,2m wide from ground floor to first floor each with one intermediate landing in duplex flats

Wrought ?

Flooring to landings of ?mm tongued and grooved boarding in ?mm m2 widths

Raking cutting to ?mm boarding m

Circular cutting to ?mm boarding m

? x ?mm Cleats m

? x ?mm Risers with rebated top edge let into and including groove in m treads

? x ?mm Treads with rounded front edge including blocking pieces m

Housed end of tread to stringer No

Quadrant rounded end to ?mm wide tread No

Semi-circular end to ?m wide tread No

? x ?mm Stringers m

? x ?mm Stringers bolted m

? x ?mm Bottom rails m

? x ?mm Four times angle rounded bottom rails m

? x ?mm Four times angle rounded continuous handrails with m dowelled heading joints

?mm Diameter continuous handrails with dowelled heading joints m

Page 92: Model Bill

Extra over ? for rounded end No

Extra over ? for scrolled end No

Extra over ? for ramp or knee No

Extra over ? for bend No

Extra over ? for wreathed ramp or knee No

Extra over ? for combined wreathed ramp and knee ?mm wide No overall on plan

Extra for framing end of ? horizontal rail into newel No

Extra for framing end of ? raking rail into newel No

? x ?mm Baluster ?mm long with bottom end framed into bottom rail No and top end framed into handrail

? x ?mm Baluster ?mm long with bottom end framed into raking No bottom rail and top end framed into raking handrail

? x ?mm Newel ?mm long with bottom end framed into stringer and No top end moulded for a length of ?mm

? x ?mm Newel ?mm long with bottom end framed into raking No stringer and top end moulded for a length of ?mm

PANELLING ETC

Sawn softwood

Wrought softwood

? x ?mm Grounds m

? x ?mm Grounds nailed m

? x ?mm Grounds plugged m

? x ?mm Grounds wrought on one face plugged m

? x ?mm Bearers m

? x ?mm Bearers nailed m

Wrought ?

Panelling of ? x ?mm vertical slats at ?mm centres (grounds m2 elsewhere)

? x ?mm Beads m

Page 93: Model Bill

? x ?mm Cover strips m

? x?mm Edge strips m

? x ?mm Skirting m

? x ?mm Rebated and moulded skirting m

? x ?mm Capping m

Interior type particle board with ? veneer

Interior type particle board with matched ? veneer

?mm Panelling ?mm high and in ?mm widths (grounds and cover m2 strips elsewhere)

?mm Panelling ?mm high and in ?mm widths fixed to and including ? m2 x ?mm wrought ? horizontal grounds at ?mm centres plugged (cover strips elsewhere)

Interior type particle board with ? veneer and veneered edges at open vertical joints

?mm Panelling ?mm high and in ?mm widths with ?mm wide open m2 joints (grounds elsewhere)

?mm Panelling ?mm high and in ?mm widths with ?mm wide open m2 joints fixed to and including ? x ?mm wrought ? horizontal grounds at ?mm centres plugged

Fibreglass sound insulation

?mm Insulation of ?kg/m density fixed to walls between grounds m2 behind panelling

Linings, backings, etc

Natural (Dyed) moth-proofed hessian stretched taut and stapled to m2 timber

Fibreglass mosquito gauze stretched taut and stapled to timber m2

Galvanised steel mosquito gauze stretched taut and stapled to timber m2

Copper mosquito gauze stretched taut and stapled to timber m2

?mm Mesh galvanised chicken wire stretched taut and stapled to m2 timber

DUCT COVERS

Sawn softwood

Page 94: Model Bill

Wrought softwood

Wrought meranti

Wrought ?

? x ?mm Grounds nailed m

? x ?mm Grounds plugged m

? x ?mm Framed frames m

? x ?mm Framed frames plugged m

? x ?mm Framed frames bolted m

? x ?mm Rebated and framed frames m

? x ?mm Rebated and framed frames plugged m

? x ?mm Rebated and framed frames bolted m

Tempered hardboard

Interior type particle board with ? veneer

?mm Duct covers in ?mm widths including chromium plated dome m2 headed screws in cup washers at ?mm centres along edges

?mm Duct cover ? x ?mm high including ? chromium plated dome No headed screws in cup washers at ?mm centres all round

JOINERY SUNDRIES

Wrought softwood

Wrought meranti

Wrought ?

Slatted shelving, seats, etc of ? x ?mm slats at ?mm centres m2

Slatted shelving, seats, etc of ? x ?mm slats at ?mm centres screwed m2 through steel including holes

Raking cutting to slatted shelving, seats, etc m

? x ?mm Bearers nailed m

? x ?mm Bearers plugged m

? x ?mm Bearers bolted m

? x ?mm Twice angle rounded chair rail plugged m

Page 95: Model Bill

? x ?mm Rebated and moulded picture rail plugged m

? x ?mm Capping plugged m

? x ?mm Coat rails nailed m

? x ?mm Coat rails plugged m

? x ?mm Twice angle rounded handrails m

? x ?mm Grooved and twice angle rounded handrails m

?mm Diameter handrails m

NOTICE BOARDS, KEYBOARDS, DUCKBOARDS, ETC

Wrought softwood

Wrought meranti

Wrought ?

? x ?mm Grounds nailed m

? x ?mm Grounds plugged m

? x ?mm Rebated surrounds plugged m

? x ? Twice rebated surrounds plugged m

? x ?mm Rebated and moulded surrounds m

? x ?mm Rebated and moulded surrounds plugged m

? x ?mm Rebated and framed frames m

? x ?mm Duckboard of ? x ?mm slats at ?mm centres fixed to ? x No ?mm cross bearers at ?mm centres

Softboard

?mm Pinning boards m2

Interior type particle board

?mm Backboards m2

?mm Backboards plugged m2

Krommenie bulletin board

Flortime Premier pinning board

Page 96: Model Bill

?mm Pinning boards ?mm high glued to backboards m2

?mm Pinning boards ?mm high glued to plastered walls m2

?mm Pinning board ? x ?mm high glued to backboard No

?mm Pinning board ? x ?mm high glued to plastered walls No

FITTINGS

User note:

a) Where fittings are required to be measured in detail they are to be given under headings - the example given covers various items contained in cupboard fittings generally

b) Generally fittings can be measured in number with a brief description of size and content with reference made to drawings which should reflect plan, elevation and section - an example is also given here (drawings, details, etc are to be submitted with the tender documentation)

c) Ironmongery and paint finishes may be specifically included or measured separately and stated as such

FIFTY CUPBOARDS IN CLASSROOMS

Sawn softwood

Wrought softwood

Wrought meranti

Wrought?

?mm Tops, shelves, sides, divisions, etc m2

?mm Tops, shelves, sides, divisions, etc exceeding 300mm wide m2

Raking cutting to ?mm timber m

Circular cutting to ?mm timber m

? x ?mm Cleats m

? x ?mm Bearers m

? x ?mm Bearers nailed m

? x ?mm Bearers plugged m

Page 97: Model Bill

? x ?mm Skirtings m

? x ?mm Edge strips m

? x ?mm Framed framing m

? x ?mm Framed framing plugged m

Drawer ? x ? x ?mm deep of ? x ?mm grooved front, ? x ?mm No grooved sides, ? x ?mm back and 3mm tempered hardboard bottom

Framed door ? x ?mm high of ? x ?mm framing in single pane No rebated all round including ? x ?mm glazed beads on one side

Tempered hardboard

?mm Backing m2

Interior type particle board with ? veneer

Novawhite particle board

? particle board with ? veneer

?mm Tops, shelves, sides, divisions, etc m2

?mm Adjustable shelving m2

Raking cutting to ?mm particle board m

Circular cutting to ?mm particle board m

?mm Cupboard door ? x ?mm high with edge strips all round No

?mm Double cupboard door ? x ?mm high with ? (flush/rebated) No meeting edges, each leaf with edge strips all round

Formica decorative laminate

?mm Thick to tops, shelves, sides, divisions, etc m2

Raking cutting to decorative laminate m

Circular cutting to decorative laminate m

?mm Thick edge strips ?mm wide m

FITTINGS

User note:

When using the following system of measuring cupboard fittings a detailed specification must either be incorporated on the detail drawings of the cupboards or included here

Page 98: Model Bill

General

The following cupboard fittings have been measured as complete units i.e. the components of the units have not been separately measured. The descriptions, therefore, of such units shall be deemed to include all components, assembling, housing, notching, glueing, blocking, planting on and screwing with countersunk screws, edge strips, decorative plastic finish, glass, ironmongery, metalwork, paint or varnish finishes, etc

User note:

The above clause is to be amended if any or all the items of other trades i.e. glass, ironmongery, metalwork, paint or varnish finishes are measured separately and a statement to this effect shall be included

The references given in the descriptions are to the respective types of fittings detailed on the architect's drawings numbered ..... annexed to these bills of quantities/accompanying these bills of quantities for tender purposes

Kitchen cupboards etc

Kitchen cupboards etc with type "?" hinges, type "?" handles and type "?" telescopic drawer slides

Wall cupboard type ? ? x ? x ?mm high with top, sides, bottom, No division, shelf, back and single hinged door

Floor cupboard type ? ? x ? x ?mm high with top, sides, bottom, No division, shelf, back and single hinged door, dividing framework and ? drawers

Sink cupboard type ? ? x ? x ?mm high with sides, bottom, No divisions, shelf, back and ? single hinged doors (sink elsewhere)

Bedroom cupboards etc

Bedroom cupboards etc with type "?" hinges, type "?" handles, type "?" roller catches to upper doors, type "?" cupboard locks to lower doors and 100mm brass barrel bolts to lower double doors

Cupboard type ? ? x ? x ?mm high with top, sides, bottom, division, No shelves, etc

Page 99: Model Bill

BILL ?

CEILINGS, PARTITIONS AND ACCESS FLOORING

SUPPLEMENTARY PREAMBLES

Descriptions:

Items described as "nailed" shall be deemed to be fixed with hardened steel nails or pins or shot pinned to brickwork or concrete

Items described as "plugged" shall be deemed to include screwing to fibre, plastic or metal plugs at not exceeding 600mm centres, and where described as "bolted" the bolts have been given elsewhere

CEILINGS ETC

Sawn softwood

Wrought softwood

Wrought meranti

Wrought ?

? x ?mm Branders m

? x ?mm Branders nailed m

? x ?mm Branders plugged m

? x ?mm Branders wrought on one face plugged m

? x ?mm Ceiling joists m

? x ?mm Runners m

? x ?mm Hangers m

?mm Quadrant beads m

? x ?mm Beads m

? x ?mm Cornices nailed m

? x ?mm Cornices plugged m

? x ?mm Splayed cornices nailed m

? x ?mm Splayed cornices plugged m

? x ?mm Rebated cornices nailed m

Page 100: Model Bill

? x ?mm Rebated cornices plugged m

Aerolite insulation

? insulation

?mm Insulation closely fitted and laid on top of brandering m2 between roof timbers etc

?mm Insulation lapped not less than ?mm along all edges and laid on m2 top of brandering between roof timbers etc

NAILED UP CEILINGS

?mm "Rhino" gypsum plasterboard

?mm "Rhino" gypsum plasterboard with ?mm wrought softwood half round cover strips over joints

?mm "Rhino" gypsum plasterboard with ? x ?mm cover strips over joints

?mm "Rhino" gypsum plasterboard with "?" cover strips over joints.

?mm "Rhino" gypsum plasterboard with "?" H-type pressed steel jointing strips

?mm "Rhino" gypsum plasterboard with taped and skimmed joints

?mm "Rhino" gypsum plasterboard with 63mm wide strips of mesh scrim nailed over joints and the whole finished with gypsum skim plaster trowelled to a smooth polished surface to the thickness recommended by the manufacturer

?mm "Everite Nutec" fibre-cement boards

?mm "Everite Nutec" fibre-cement boards with ? x ?mm cover strips over joints

?mm "Everite Nutec" fibre-cement boards with "?" H-type pressed steel jointing strips

Ceilings including ? x ?mm sawn softwood brandering at ?mm m2 centres

Sloping ceilings including ? x ?mm sawn softwood brandering at m2 ?mm centres

Vertical ceilings including ? x ?mm sawn softwood brandering at m2 ?mm centres

Page 101: Model Bill

Ceilings including ? x ?mm sawn softwood brandering at ?mm m2 centres and ? x ?mm sawn softwood cross brandering at ?mm centres

Sloping ceilings including ? x ?mm sawn softwood brandering at m2 ?mm centres and ? x ?mm sawn softwood cross brandering at ?mm centres

Vertical ceilings including ? x ?mm sawn softwood brandering at m2 ?mm centres and ? x ?mm sawn softwood cross brandering at ?mm centres

Circular cutting m

Soffit and side of horizontal bulkheads, size ? x ?mm deep, including m ? x ?mm sawn softwood brandering at ?mm centres

Soffit and side of sloping bulkheads, size ? x ?mm deep, including ? x m ?mm sawn softwood brandering at ?mm centres

Soffit and side of horizontal bulkheads, size ? x ?mm deep, including m ? x ?mm sawn softwood brandering at ?mm centres and ? x ?mm sawn softwood cross brandering at ?mm centres

Soffit and side of sloping bulkheads, size ? x ?mm deep, inluding ? x m ?mm sawn softwood brandering at ?mm centres and ? x ?mm sawn softwood cross brandering at ?mm centres

Opening for sprinkler head No

Extra over ceiling for opening for ?mm diameter downlighter No

Extra over ceiling for opening for ? x ?mm light fitting No

Extra over ceiling for ? x ?mm opening for ventilation/air No conditioning diffuser

Extra over ceiling for ? x ?mm trap door of ? x ?mm wrought No softwood rebated framing with one ? x ?mm sawn softwood cross brander covered with ceiling board and fitted flush in opening

Rhino gypsum plasterboard cornices

75mm Coved cornices m

Pre-painted "?" acoustic panels with bevelled edge

Page 102: Model Bill

Ceilings of ? x ? x ?mm panels including ? x ?mm sawn softwood m2 brandering at ?mm centres in both directions

Ceilings of ? x ? x ?mm panels including ? x ?mm sawn softwood m2 brandering at ?mm centres and ? x ?mm sawn softwood cross brandering at ?mm centres

Circular cutting m

SUSPENDED CEILINGS

Proprietary suspended ceilings

Note:

Electrical light fittings, diffusers, panels, etc generally are "lay in" units of the same dimensions as the suspension grid described and allowance must be made accordingly for their support inclusive of any flexibility insetting out that may be required (ceiling panels have not been deducted and pricing is to take cognisance thereof)

User note:

a) The above note to be included in the bills of quantities after confirmation of the basic design of the ceilings, lighting, air conditioning, etc

Pre-painted ? x ? x ?mm "?" acoustic panels on "?" pre-painted exposed tee suspension system including main and cross tees, necessary hangers, grids, etc

Pre-painted ? x ? x ?mm "?" chamfered and grooved acoustic panels on "?" concealed tee suspension system including main and cross tees, necessary hangers, grids, etc

Ceilings suspended not exceeding 1m below concrete soffits m2

Sloping ceilings suspended not exceeding 1m below concrete m2 soffits

Ceilings suspended exceeding ?m and not exceeding ?m below m2 concrete soffits

Sloping ceilings suspended exceeding ?m and not exceeding ?m m2 below concrete soffits

Ceilings suspended not exceeding 1m below timber/steel purlins at m2 ?mm centres (trusses at ?m centres)

Sloping ceilings suspended not exceeding 1m below timber/steel m2

Page 103: Model Bill

purlins at ?mm centres (trusses at ?m centres)

Ceilings suspended exceeding ?m and not exceeding ?m below m2 timber/steel purlins at ?mm centres (trusses at ?m centres)

Sloping ceilings suspended exceeding ?m and not exceeding ?m m2 below timber/steel purlins at ?mm centres (trusses at ?m centres)

Suspended vertical ceilings m2

Circular cutting m

Soffit and side of horizontal bulkheads, size ? x ?mm deep, suspended m not exceeding 1m below concrete soffits

Soffit and side of horizontal bulkheads, size ? x ?mm deep, suspended m exceeding ?m and not exceeding ?m below concrete soffits

Soffit and side of horizontal bulkheads, size ? x ?mm deep, suspended m not exceeding 1m below timber/steel purlins at ?mm centres (trusses at ?m centres)

Soffit and side of horizontal bulkheads, size ? x ?mm deep, suspended m exceeding ?m and not exceeding ?m below timber/steel purlins at ?mm centres (trusses at ?m centres)

Soffit and side of sloping bulkheads, size ? x ?mm deep, suspended m exceeding ?m and not exceeding ?m below concrete soffits

Soffit and side of sloping bulkheads, size ? x ?mm deep, suspended m exceeding ?m and not exceeding ?m below timber/steel purlins at ?mm centres (trusses at ?m centres)

Opening for sprinkler head No

Extra over ceiling for opening for ?mm diameter downlighter No

Extra over ceiling for opening for ? x ? mm light fitting No

Extra over ceiling for ? x ?mm opening for ventilation/air No conditioning diffuser

Page 104: Model Bill

? cornices to suspended ceilings

? pre-painted cornices plugged m

PARTITIONS ETC

Rhino-Drywall partition systems

Rhino-Drywall partitioning shall comprise steel studding formed of ?mm top and bottom tracks with vertical studs at maximum ?mm centres, friction fitted or pop-riveted to the top and bottom tracks with similar additional vertical studs as necessary at abutments, ends, etc and covered as described with wallboard screwed to studding with "Drywall" screws at maximum 220mm centres. Boards are to be butt jointed and finished with "Rhino" tape and "Readymix D" jointing compound all in accordance with the manufacturer's instructions. Intersections and abutments are measured separately and descriptions shall be deemed to include any additional studs, corner beads, jointing compound, tape, etc

Note: Wall paper and/or paint and varnish finishes are measured elsewhere

Rhino-Drywall System No 1 steel stud partitioning with "Rhino Wallboard" on both sides

Rhino-Drywall System No ? steel stud partitioning with "Rhino Wallboard" on both sides

Rhino-Drywall System No 7 steel stud partitioning with "Rhino Firestop Board" on both sides and fibreglass blanket between (? hour fire rating)

Partitioning ?m high with bottom and top tracks plugged m

Partitioning ?m high with bottom track plugged and top track fixed m to suspended ceiling tees

Partitioning ?m high with top and bottom tracks plugged and m glazing in lieu of boarding ?m high at ?m above floor level, framed all round with "Drywall" aluminium glazing sections and divided into panels with aluminium mullions at ?mcentres with each panel glazed with ?mm clear float glass including neoprene glazing gaskets

Extra over partition ?m high for vertical abutment No

Extra over partition ?m high for corner No

Extra over partition ?m high for T-intersection No

Extra over partition ?m high for fair end No

Extra over partition ?m high for "?" No

Page 105: Model Bill

Doors

Extra over partition for 40mm semi-solid flush door ? x ?mm high No with "?" veneer on both sides and hardwood edge strips to vertical edges hung to and including standard pressed steel door frame with one pair of 100mm steel hinges including"?" lockset and additional studding, trimming, etc

Extra over partition for 40mm semi-solid flush door ? x ?mm high No with "?" veneer on both sides and hardwood edge strips to vertical edges and ? x ?mm opening for louvre unit hung to and including standard pressed steel door frame with one pair of 100mm steel hinges including "?" lockset and additional studding, trimming, etc

Extra over partition for 40mm semi-solid flush door ? x ?mm high No with "?" veneer on both sides and hardwood edge strips to vertical edges hung to and including standard natural anodised aluminium door frame with one pair of 100mm nylon washered aluminium hinges including "?" lockset and additional studding, trimming, etc

Extra over partition for 40mm semi-solid flush door ? x ?mm high No with "?" veneer on both sides and hardwood edge strips to vertical edges and ? x ?mm opening for louvre unit hung to and including standard natural anodised aluminium door frame with one pair of 100mm nylon washered aluminium hinges including "?" lockset and additional studding, trimming, etc

Extra over partition for 40mm semi-solid flush double door ? x No ?mm high with "?" veneer on both sides and hardwood edge strips to vertical edges hung to and including standard pressed steel door frame with two pairs of 100mm steel hinges including two "?" barrel bolts, "?" lockset and additional studding, trimming, etc

Extra over partition for 40mm semi-solid flush double door ? x No ?mm high with "?" veneer on both sides and hardwood edge strips to vertical edges and two ? x ?mm openings for louvre units hung to and including standard pressed steel door frame with two pairs of 100mm steel hinges including two "?" barrel bolts, "?" lockset and additional studding, trimming, etc

Extra over partition for 40mm semi-solid flush double door ? x No ?mm high with "?" veneer on both sides and hardwood edge strips to vertical edges hung to and including standard natural anodised aluminium door frame with two pairs of 100mm nylon washered aluminium hinges including two "?" barrel bolts, "?" lockset and additional studding, trimming, etc

Extra over partition for 40mm semi-solid flush double door ? x No ?mm high with "?" veneer on both sides and hardwood edge strips to vertical edges and two ? x ?mm openings for louvre units hung to and including standard natural anodised aluminium door frame with two pairs of 100mm nylon washered aluminium hinges including two "?"

Page 106: Model Bill

barrel bolts, "?" lockset and additional studding, trimming, etc

Insulation

?mm Thick "?" fibreglass insulation blanket in cavity of m2 partitioning

DEMOUNTABLE PARTITIONS

Donn Vanguard partition systems

Demountable partitions are to be "Donn Vanguard" with an overall thickness of 76mm comprising 50mm wide galvanised steel tracks and studs with one layer of 12,7mm gypsum plasterboard in 1,2m modules on each side and flat section aluminium skirtings and recessed aluminium cornices. The panels are to be covered with "?" wall paper wrapped around edges. Aluminium door frames and glazing sections, skirtings, cornices, etc are to be natural anodised aluminium. The partitions are to be erected in accordance with the manufacturer's instructions

Partitioning ?m high with bottom and top tracks plugged m

Partitioning ?m high with bottom tracks plugged and top tracks m fixed to suspended ceiling tees

Partitioning ?m high with lower solid section ?m high and upper m section ?m high glazed with ?mm clear float glass

Extra over partition ?m high for vertical abutment No

Extra over partition ?m high for vinyl covered corner No

Extra over partition ?m high for irregular vinyl covered corner No

Extra over partition ?m high for vinyl covered fair end No

Extra over partition ?m high for T-intersection of solid No partitioning

Extra over partition ?m high for Y-intersection of solid with half No glazed partitioning including vinyl covered module infill

Extra over partition ?m high for "?" No

Doors

Extra over partition for 40mm semi-solid flush door ? x ?mm high No with "?" veneer on both sides and hardwood edge strips to vertical edges hung to and including standard natural anodised

Page 107: Model Bill

aluminium door frame with one pair of 100mm nylon washered aluminium hinges including "?" lockset and additional studding, trimming, etc

Extra over partition for 40mm semi-solid flush door ? x ?mm high No with "?" veneer on both sides and hardwood edge strips to vertical edges and ? x ?mm opening for louvre unit hung to and including standard natural anodised aluminium door frame with one pair of 100mm nylon washered aluminium hinges including "?" lockset and additional studding, trimming, etc

Extra over partition for 40mm semi solid flush double door ? x ? mm No high with "?" veneer on both sides and hardwood edge strips to vertical edges hung to and including standard natural anodised aluminium door frame with two pairs of 100mm nylon washered aluminium hinges including two "?" barrel bolts, "?" lockset and additional studding, trimming, etc

Extra over partition for 40mm semi-solid flush double door ? x No ?mm high with "?" veneer on both sides and hardwood edge strips to vertical edges and two ? x ?mm openings for louvre units hung to and including standard natural anodised aluminium door frame with two pairs of 100mm nylon washered aluminium hinges including two "?" barrel bolts, "?" lockset and additional studding, trimming, etc

Insulation

?mm Thick "?" fibreglass insulation blanket in cavity of m2 partitioning

TOILET PARTITIONS

Vitraflex toilet partitioning with 20mm thick "?" faced particle board bonded panels and natural anodised aluminium edging and top rails including fixing components and standard ironmongery comprising indicator bolts, coat hooks with door stops, toilet roll holders and rubber buffers

Vitraflex toilet partitioning with 20mm thick vitreous enamelled steel sheet faced particle board bonded panels and natural anodised aluminium edging and top rails including fixing components and standard ironmongery comprising indicator bolts, coat hooks and doors stops, toilet roll holders and rubber buffers

Partition ? x ?m high No

Full stile ? x ?m high No

Wall stile ?mm wide and ?m high No

End stile ?mm wide and ?m high No

Page 108: Model Bill

Door ? x ?mm high No

ACCESS FLOORING

User note:

When access flooring is to be included in the bills of quantities, other than by means of a provisional sum, supplementary preambles in the form of technical specifications and descriptions are to be compiled in conjunction with specialists in this field and thoroughly investigated and checked to ascertain their correctness for the works before they are included in the document.

The following items are based on a particular manufacturer's system for a particular contract and must be used as a guide to items required to be included

Class "?" access flooring

? x ?mm Modular and interchangeable steel panel access flooring m2 including pedestals and panels finished with factory bonded "?" (access flooring to finish ?mm above the concrete sub-floor)

? x ?mm Modular and interchangeable steel panel access flooring m2 including stringers and pedestals and panels finished with ? carpet tiles glued on with approved adhesive (access flooring to finish ?mm above the concrete sub-floor)

? x ?mm Modular and interchangeable steel panel access flooring m2 including stringers and pedestals and panels with cementitious filling finished with factory bonded 1,3mm thick laminate (access flooring to finish ?mm above the concrete sub-floor)

Junctions against walls and columns m

Junctions against circular walls and columns m

Hole for ?mm diameter pipe through floor panel including sealing No

? x ?mm Opening through floor panel for air conditioning grille No

Supplying, erecting, dismantling and removing from site ? x ? x Item ?mm high sample of class "?" access flooring (refer "?" of access floor specification)

Sundries

Fire barrier/divider ?mm high between concrete sub-floor and floor m panels

Page 109: Model Bill

Hole for ?mm diameter pipe through fire barrier including No sealing

Hole for ? x ?mm metal duct through fire barrier including No sealing

30 Pin type panel lifting device No

Double suction type panel lifting device No

Spare floor panel finished with ? handed to employer No

BILL ?

FLOOR COVERINGS, PLASTIC LININGS, ETC

FLOOR COVERINGS

8mm Brown Rhodesian teak mosaic wood blocks

? x ?mm Brown Rhodesian teak wood blocks to ? pattern

300 x 300 x ? mm "Dunlop Save" thermoplastic vinyl tiles

300 x 300 x ? mm "Krommenie Thrift" economy vinyl tiles

300 x 300 x 2mm "Marley Economy plus" thermoplastic tiles

300 x 300 x ? mm "Dunlop Vinylex" semi-flexible vinyl tiles

300 x 300 x 2,5mm "Dunlop Travertine" semi-flexible vinyl tiles

300 x 300 x ? mm "Krommenie Colovinyl" semi-flexible vinyl tiles

300 x 300 x ? mm "Marleyflex" semi-flexible vinyl tiles

300 x 300 x 2mm "Dunlop Semflor" fully flexible vinyl tiles

300 x 300 x 2,5mm "Marley Travertine" fully flexible vinyl tiles

300 x 300 x ?mm "Marley HD" fully flexible vinyl tiles

?mm "Dunlop Semflor" fully flexible vinyl sheeting (with welded joints ?)

2mm "Krommenie Coloflor" fully flexible vinyl sheeting (with welded joints?)

2mm "Marley HD" fully flexible vinyl sheeting (with welded joints ?)

2,5mm "Marley Travertine" fully flexible vinyl sheeting (with

Page 110: Model Bill

welded joints ?)

1,5mm "Krommenie Novilon Star" cushion vinyl sheeting

2mm "Krommenie Novilon Studio" cushion vinyl sheeting

?mm "Marley Vynaplus" cushion vinyl sheeting

?mm "Marley Spring" cushion vinyl sheeting

?mm "Marley Tuftred" fully flexible vinyl cork sheeting

?mm "Krommenie Linoleum" natural marbled sheeting

? polypropylene needlepunch carpeting

? foam backed polypropylene needlepunch carpeting

500 x 500mm "?" carpet tiles

? tufted carpeting including felt underlay etc

? woven pile carpeting including felt underlay etc

On floors m2

On dished floors m2

On treads and risers of stepped floors m2

On treads and risers of stairs m2

On treads and risers of winding stairs m2

Margins and borders not exceeding 500mm wide m

Turn-ups over coves and up against walls not exceeding 500mm girth m

Inserts ? mm wide of differing colour m

Circular cutting m

WALL LININGS

? mm "Dunlop Semflor" fully flexible vinyl sheeting (with welded joints ?)

?mm "Krommenie Colorific" fully flexible vinyl sheeting (with welded joints ?)

Page 111: Model Bill

?mm "Marley HD" fully flexible vinyl sheeting (with welded joints ?)

? tufted carpeting glued on

? woven pile carpeting glued on

? tufted carpeting secured to wooden framing including gripper strips etc

? woven pile carpeting secured to wooden framing including gripper strips etc

On walls m2

On circular walls m2

Circular cutting m

SKIRTINGS, NOSINGS, ETC

Dunlop

Krommenie

Marley Extruda

Bildon

? mm ? vinyl edging m

? mm ? vinyl edging stepped over treads and risers of stairs m

? mm ? vinyl skirtings m

? mm ? vinyl skirtings stepped over treads and risers of stairs m

? mm ? vinyl stair nosings m

? mm ? vinyl combined tread and riser covering m

? mm ? natural (colour ?) anodised cover strips fixed to concrete m

? mm ? natural (colour ?) anodised aluminium nosing with PVC m inset(s) fixed to concrete

HANDRAILS

Marley Extruda vinyl handrails

? vinyl handrails

MHR1 handrails fitted over 40 x 6mm core rail m

Page 112: Model Bill

MHR2 handrails fitted over 40 x 10mm core rail m

MHR3 handrails fitted over 50 x 6mm core rail m

MHR4 handrails fitted over 50 x 10mm core rail m

? Handrails fitted over ? x ? mm core rail m

POLISH, SEALERS, ETC

? coats wax polish on vinyl flooring m2

BILL ?

IRONMONGERY

SUPPLEMENTARY PREAMBLES

Finishes to ironmongery

Where applicable finishes to ironmongery are indicated by suffixes in accordance with the following list:

BS Satin bronze lacquered CH Chromium plated

SC Satin chromium plated

SE Silver enamelled

GE Grey enamelled

AS Anodised silver

AB Anodised bronze

AG Anodised gold

ABL Anodised black

PB Polished brass

PL Polished and lacquered

PT Epoxy coated

SD Sanded

HINGES, BOLTS, ETC

Solid

Townsend

?mm (Open) brass plated piano hinge m

Page 113: Model Bill

?mm (Open) brass piano hinge m

?mm (Open) chromium plated piano hinge m

?mm Steel hinge No

?mm Steel rising hinge No

?mm Brass hinge No

?mm Brass hinge with steel washers No

?mm Brass hinge with nylon washers No

?mm Brass hinge with bronze washers No

? x ?mm Brass parliament hinge No

? Satin chromium plated single action floor spring hinge with (out ?) No stand open feature including adjustable top centre and box let into concrete

? Satin chromium plated double action floor spring hinge with (out ?) No stand open feature including adjustable top centre and box let into concrete

?mm Brass barrel bolt No

?mm Brass barrel bolt with keep fixed to metal No

?mm Brass barrel bolt with keep let into concrete No

?mm Chromium plated brass barrel bolt No

?mm ? barrel bolt No

?mm ? barrel bolt with keep fixed to metal No

?mm ? barrel bolt with keep let into concrete No

?mm ? necked barrel bolt No

?mm ? flush bolt No

?mm ? flush bolt with keep fixed to metal No

?mm ? flush bolt with keep let into concrete No

? WC indicator bolt No

? WC indicator bolt with keep fixed to metal No

? panic bolt for single door ?mm high No

Page 114: Model Bill

? panic bolt for single door ?mm high with one keep let into concrete No

? panic bolt for double door ?mm high No

? panic bolt for double door ?mm high with one keep let into No concrete

CATCHES, CABIN HOOKS, ETC

Solid

Union

Halcast

?mm ? ball catch No

? Single roller catch No

? Double roller catch No

? Fanlight catch No

? Fanlight stay No

? Fanlight friction sliding arm No

?mm ? Fanlight opener with cord and cleat No

? cabin hook and eye No

? cabin hook and eye including 70 x 70 x 20mm chamfered No hardwood block twice oiled and plugged

LOCKS

EN-SUITE LOCKS

Solid

Union

The following locks are to be suitable for master key operation

The following locks are to be suitable for master and grand master key operation

? Padlock No

?mm ? padlock No

? Latchset No

Page 115: Model Bill

? rim night latch No

? bathroom lockset No

? bathroom lockset with striking plate fixed to metal No

? three lever deadlock No

? three lever rebated deadlock No

? four lever deadlock No

? four lever rebated deadlock No

? two lever lockset No

? two lever lockset with striking plate fixed to metal No

? two lever rebated lockset No

? three lever lockset No

? three lever lockset with striking plate fixed to metal No

? three lever rebated lockset No

? four lever lockset No

? four lever lockset with striking plate fixed to metal No

? four lever rebated lockset No

? three lever sliding door lock No

? four lever sliding door lock No

? single cylinder deadlock No

? single cylinder rebated deadlock No

? double cylinder deadlock No

? double cylinder rebated deadlock No

? single cylinder lockset No

? single cylinder lockset with striking plate fixed to metal No

? single cylinder rebated lockset No

? double cylinder lockset No

? double cylinder lockset with striking plate fixed to metal No

Page 116: Model Bill

? double cylinder rebated lockset No

? single cylinder sliding door lock No

? double cylinder sliding door lock No

Master key No

Grand master key No

HANDLES

Solid

Union

Modric

Hewi

?mm Brass flush handle No

?mm ? flush handle No

?mm ? knob No

?mm Brass pull handle No

?mm ? pull handle No

Set of two ?mm ? pull handles fixed back to back No

PUSH PLATES AND KICKING PLATES

Solid

Union

? x ? x ?mm Thick ? anodised aluminium ? plate No

? x ? x ?mm Thick satin finished stainless steel ? plate No

? x ? x ?mm Thick polished brass ? plate No

? anodised aluminium ? plate No

? satin finished stainless steel ? plate No

? polished brass ? plate No

DOOR CLOSERS

Solid

Page 117: Model Bill

Union

Newman Tonks

Dorma

? door closer No

? door closer with bracket fixed to metal No

? concealed door closer No

? concealed door closer with bracket fixed to metal No

SLIDING GEAR

Hillaldam

Hendersons

? sliding gear set for single door with track ?m long fixed to ? No including brackets, hangers, rollers, guides, stops, etc

? sliding gear set for bi-parting door with track ?m long fixed to ? No including brackets, hangers, rollers, guides, stops, etc

? sliding gear set for set of ? folding doors with track ?m long fixed No to ? including brackets, hangers, rollers, guides, stops, etc (hinges elsewhere)

LETTERS, NAMEPLATES, ETC

Solid

Union

?mm High plastic letter or numeral No

?mm High brass letter or numeral No

? x ? x ?mm Thick perspex plate with ? ?mm high engraved and No painted letters or numerals

? x ? x ?mm Thick ? plate with ? ?mm high engraved and painted No letters or numerals

? x ?mm ? anodised aluminium plate with male or female symbol No

? x ?mm ? anodised aluminium plate with paraplegic symbol No

? x ?mm ? anodised aluminium plate with fire exit, fire extinguisher, No fire hose reel or fire hydrant symbol

PELMETS AND CURTAIN TRACKS

Page 118: Model Bill

National

Kirsch

Swish

Pressed steel pelmet ?mm high with ?mm projection including single m (double ?) curtain track with 12 rollers per metre, brackets, returned ends, etc plugged

? single (double ?) curtain track for soffit fixing including 14 rollers m per metre, brackets, stopped ends, etc (plugged ?)

? single (double ?) curtain track for face fixing with ?mm projection m including 14 rollers per metre, brackets, stopped ends, etc (plugged ?)

? hospital cubicle curtain track ?mm below soffit including 12 gliders m per metre, hangers, brackets, stopped ends, etc (plugged ?)

Extra for end plugged No

Extra for bend No

Extra for joint at bend No

BATHROOM FITTINGS

Design Syndicate Contracts

Halcast

Kimberley-Clark

Solid

?mm Diameter chromium plated curtain or hanging rail ?mm long No including flanged end brackets

?mm Diameter chromium plated curtain or hanging rail ?mm long No including flanged end brackets plugged

?mm Diameter chromium plated towel rail ?mm long including end No brackets

?mm Diameter chromium plated towel rail ?mm long including end No brackets plugged

? towel ring No

? towel ring plugged No

? chromium plated toilet roll holder plugged No

Page 119: Model Bill

Lockable toilet roll holder plugged No

? soap holder plugged No

Vaal Paragon

32mm Type 9 back grab rail 800mm long plugged No

32mm Type 8 side grab rail 900mm girth plugged No

Elvinco

Masterbilt

? x ?mm High ? bathroom cabinet plugged No

SUNDRIES

Solid

Union

? Diameter steel dowel ?mm long in and including mortice in timber No and brickwork or concrete

38mm Diameter rubber door stop No

38mm Diameter rubber door stop plugged No

? door stop plugged No

? brass coat hook No

? ? coat hook No

? brass hat and coat hook No

? ? hat and coat hook No

? brass hat and coat hook with rubber buffer No

? ? hat and coat hook with rubber buffer No

32mm Diameter polished hardwood long arm ?m long with brass pole No hook on one end, two broom clips each with 20 x 100 x 100mm wrought and chamfered hardwood block twice oiled and plugged and 20 x 70 x 70mm wrought and chamfered hardwood block with sinking twice oiled and plugged

Emseal

Page 120: Model Bill

Clipstrip

? anodised aluminium cover strip fixed over expansion joints in m floors

? anodised aluminium cover strip fixed over expansion joints in walls m and ceilings

? nylon and aluminium smoke sealing strip let into edges of doors m

Raven

? sealing strip fixed to top and edges of ? x ?mm high single door No

? sealing strip fixed to bottom of ?mm wide single door No

Coir mats

Rubber mats

Squeegee mats

? x ? x ?mm Door mat laid loose in mat surround No

? x ? x ?mm ? door mat laid loose in mat surround No

SHELVES ETC

Shelvit with standard epoxy powder coated finish

? with standard epoxy powder coated finish

? single slot wall band plugged m

? double slot wall band plugged m

? shelf bracket No

?mm ? shelf bracket No

? shelf No

? x ?mm ? shelf No

Shelvit free standing steel shelving units with standard epoxy powder coated finish including heavy duty uprights, open base foot pieces, shelf brackets, shelves, spacers, top rails, top finishing plates and adjustable book clips

Single (Double ?) shelving unit ? x ? x ?m high in ? bays with ? No uprights, each bay 914mm wide with ? x ?mm shelves

STEEL LOCKERS

Page 121: Model Bill

Greenfield steel lockers with standard baked enamel finish

? steel lockers with standard baked enamel finish

? locker ? x ? x ?mm high No

Bank of ? lockers each ? x ? x ?mm high bolted together No

KITCHEN CUPBOARDS

Kitchen Trends kitchen cupboards plugged

Modulus kitchen cupboards plugged

? kitchen cupboards plugged

? wall unit ? x ? x ?mm high No

? floor unit ? x ? x ?mm high No

? floor unit ? x ? x ?mm high with doors and drawers fitted with locks No

? sink unit ? x ? x ?mm high No

PINNING BOARDS, WRITING BOARDS, PROJECTION SCREENS, ETC

Vitrex

Didacta

Mirrodex

? pinning board ? x ?mm high plugged No

? green (white?) writing board ? x ?mm high with chalk rail plugged No

? green (white?) folding type writing board, with wall mounted No centre board ? x ?mm high with chalk rail and two swing leaves each ? x ?mm high plugged

? column mounted vertical sliding type green (white?) writing board No with two boards each ? x ?mm high with chalk rail and pair of columns ?mm high plugged

? tilting spring roller wall mounted projection screen ? x ?mm high No including overhead brackets plugged

BILL ?

STRUCTURAL STEELWORK

Page 122: Model Bill

SUPPLEMENTARY PREAMBLES

Descriptions

Descriptions of bolts shall be deemed to include nuts and washers

Descriptions of L-shaped and U-shaped anchor bolts shall be deemed to include bending, threading, nuts and washers and embedding in concrete

Descriptions of expansion anchors and bolts and chemical anchors and bolts shall be deemed to include nuts, washers and mortices in brickwork or concrete

Descriptions of L-shaped and U-shaped anchor bolts shall be deemed to include bending, threading, nuts and washers and embedding in concrete. Where anchor bolts are described as embedded in sides or soffits of concrete it shall be deemed to include holes through formwork.

Descriptions of expansion anchors and bolts and chemical anchors and bolts shall be deemed to include nuts, washers and mortices in brickwork or concrete.

STEEL COLUMNS AND BEAMS

Welded columns in single lengths with flat section base, top, bearer and connection plates bolted to ?

? x ?mm x ?kg/m ?-section columns t

? x ?mm x ?kg/m ?-section columns in lengths exceeding 13m and t not exceeding 18m

? x ?mm x ?kg/m ?-section columns in lengths exceeding ?m and not t exceeding ?m

Welded beams in single lengths with flat section bearer and connection plates bolted to ? columns

? x ?mm x ?kg/m ?-section beams t

? x ?mm x ?kg/m ?-section beams in lengths exceeding 13m and not t exceeding 18m

Page 123: Model Bill

? x ?mm x ?kg/m ?-section beams in lengths exceeding ?m and not t exceeding ?m

Welded lattice columns formed of ? x ? x ?mm, ? x ? x ?mm, ? x ? x ?mm and ? x ? x ?mm angle section framework and bracing with flat section base, top, bearer, gusset and connection plates bolted to ?

? x ?mm Lattice columns ?m high t

? x ?mm Lattice columns in heights varying from ?m to ?m t

Welded lattice beams formed of ? x ? x ?mm, ? x ? x ?mm, ? x ? x ?mm and ? x ? x ?mm angle section framework and bracing with flat section bearer, gusset and connection plates bolted to ? columns

? x ?mm High lattice beams ?m long t

? x ?mm High lattice beams in lengths varying from ?m to ?m t

Bolts to columns, beams, etc

High tensile bolts t

High strength friction grip bolts t

?mm Diameter L-shaped anchor bolt ?mm girth embedded in top of No concrete.

?mm Diameter U-shaped anchor bolt ?mm girth embedded in top of No concrete.

?mm ? expansion bolt No

?mm ? expansion anchor with loose bolt No

?mm ? chemical expansion bolt No

?mm ? chemical expansion anchor with loose bolt No

STEEL TRUSSES ETC

Welded portal frames with flat section bearer, gusset and connection plates and L-section cleats bolted to concrete

? (No) double pitched portal frame(s) of ? x ?mm x ?kg/m ?-section t rafters and columns, the truss ? x ?m high extreme and the columns ?m high

Page 124: Model Bill

? (No) double pitched portal frame(s) in two sections bolted together t at apex of ? x ?mm x ?kg/m ?-section rafters and columns, the truss ? x ?m high extreme and the columns ?m high

Welded roof trusses of angle section rails, struts, braces, cleats, etc and flat section bearer, gusset and connection plates bolted to steel

? (No) monopitched truss(es) ? x ?m high extreme t

? (No) double pitched truss(es) ? x ?m high extreme t

? (No) lattice truss(es) ? x ?m high extreme t

? (No) lattice truss(es) in two sections bolted together ? x ?m high t extreme

Bolts to trusses etc

High tensile bolts t

High strength friction grip bolts t

?mm Diameter L-shaped anchor bolt ?mm girth No

?mm Diameter U-shaped anchor bolt ?mm girth embedded in side or No soffit of concrete.

?mm ? expansion bolt No

?mm ? expansion anchor with loose bolt No

?mm ? chemical expansion bolt No

?mm ? chemical expansion anchor with loose bolt No

PURLINS, GIRTS, BRACING, ETC

Purlins and girts bolted to steel

Angle section purlins t

Angle section girts t

Lipped channel section purlins t

Lipped channel section girts t

Purlins formed of two lipped channel sections welded back to back t

Welded bracing etc with flat section connection plates bolted to

Page 125: Model Bill

steel

Angle section bracing t

Angle section sag rails t

Round sag rods with threaded ends t

Welded box gutter bearers with flat section cleats bolted to steel

Angle section longitudinal bearers t

Angle section cross bearers t

GUTTERS AND RAINWATER PIPES

?mm Welded sheet steel gutters

Box gutters ?mm girth ? times bent along length t

?mm Welded sheet steel rainwater pipes including holderbats, brackets, etc

?mm Internal diameter pipes t

HAILGUARDS

? type ? galvanised expanded metal

Hailguards ?mm wide laid loose over box gutters m

Hailguards ?mm girth ? times bent along length laid loose in box m gutters

STEEL FLOORS, STAIRS, ETC

Welded and bolted suspended floor and stairs to ?

? x ?mm x ?kg/m ?-section columns t

? x ?mm x ?kg/m ?-section bearers t

Framing to stair ? x ?m overall on plan and rising approximately ?m t high of ? section columns, ? section bearers and ? section stringers

?mm "Vastrap" plate floor panels t

?mm "Vastrap" plate treads ? x ?mm long with ?mm turn-down t nosing

?mm ? expansion bolt No

? type ? non-slip raised dimple floor panels with ? x ?mm longitudinal bearer bars welded to bearers

Page 126: Model Bill

Floor of unbanded panels t

Floor of ? x ?mm banded panels t

Circular cutting m

Banded tread ?mm wide and ?mm long No

? type ? expanded metal walkway mesh with standard flow coat bitumastic paint finish fixed to bearers with standard fixing clips

Floor in suitable widths and lengths m2

Circular cutting m

? welded and bolted patent balustrading to stairs

Horizontal/Raking balustrading ?mm high of ?mm diameter m continuous top and bottom rails and ?mm diameter type ? stanchions at average ?m centres bolted to steel bearers

Extra over ? for angle intersection of horizontal balustrading No

Extra over ? for ramped intersection of horizontal and raking No balustrading

Extra over ? for ramped intersection of horizontal and raking No balustrading at angle

Extra over ? for straight end closure piece No

Extra over ? for 45 degree angle end closure piece No

BILL?

METALWORK

SUPPLEMENTARY PREAMBLES

Descriptions

Descriptions of bolts shall be deemed to include nuts and washers

Descriptions of expansion anchors and bolts and chemical anchors and bolts shall be deemed to include nuts, washers and mortices in brickwork or concrete

Metalwork described as"holed for bolt(s)" shall be deemed to exclude

Page 127: Model Bill

the bolts unless otherwise described

STEEL HANDRAILS, BALUSTRADES, ETC

GALVANIZED STEEL HANDRAILS, BALUSTRADES, ETC

Welded handrails to ?

? x ?mm Flat section continuous rails kg

? x ? x ?mm Hollow section continuous rails m

?mm External diameter ?mm thick continuous pipe rails m

Extra over ? for fanged end No

Extra over ? for rounded end No

Extra over ? for flat closed end No

Extra over ? for rounded closed end No

Extra over ? for L-intersection No

Extra over ? for mitred L-intersection No

Extra over ? for T-intersection No

Extra over ? for ramp or knee No

Extra over ? for bend to ?mm internal radius No

Extra over ? for bend across edge No

Extra over ? for bend across edge to ?mm internal radius No

Extra over ? for wreathed ramp or knee No

Extra over ? for combined wreathed ramp and knee No

Bracket formed of ?mm diameter bar ?mm girth once bent to ?mm No internal radius with one end welded to rail and other end welded to and including ?mm diameter ?mm thick plate ? holed for bolt(s)

?mm ? expansion bolt No

?mm ? expansion anchor with loose bolt No

Welded balustrading to ?

? x ?mm Flat section continuous handrails kg

Page 128: Model Bill

? x ?mm Flat section continuous middle and bottom rails kg

? x ?mm Flat section balusters kg

? x ?mm Balusters kg

?mm Diameter balusters kg

Bolts kg

? x ? x ?mm Hollow section continuous handrails m

? x ? x ?mm Hollow section balusters m

?mm External diameter ?mm thick continuous pipe handrails m

?mm External diameter ?mm thick pipe balusters m

Extra over ? for fanged end No

Extra over ? for rounded end No

Extra over ? for flat closed end No

Extra over ? for rounded closed end No

Extra over ? for L-intersection No

Extra over ? for mitred L-intersection No

Extra over ? for T-intersection No

*Extra over ? for framed X-intersection No

Extra over ? for ramp or knee No

Extra over ? for bend No

Extra over ? for bend to ?mm internal radius No

Extra over ? for bend across edge No

Extra over ? for bend across edge to ?mm internal radius No

Extra over ? for wreathed ramp or knee No

Extra over ? for combined wreathed ramp and knee No

?mm Diameter threaded lug ?mm long with one end welded on and No other end fitted with nut and washer

? x ? x ?mm Fixing plate ? holed for bolt(s) and welded on No

Page 129: Model Bill

L-shaped bracket formed of ? x ?mm flat section ?mm girth ? holed No for bolt(s) and welded on

Handrail bracket formed of ?mm diameter bar ?mm girth once bent to No ?mm internal radius with one end welded to rail and other end welded to and including ?mm diameter ?mm thick plate ? holed for bolt(s)

Hole through ?mm steel for bolt No

Slotted hole through ?mm steel for bolt No

?mm ? expansion bolt No

?mm ? expansion anchor with loose bolt No

Welded balustrading to ?

? x ? x ?mm Welded mesh infill panels ?mm high and in single m lengths spot welded to sub-framing

? x ? x ?mm Angle section sub-framing spot welded to framing kg

Extra over ? for mitred L-intersection No

? x ? x ?mm Hollow section framing m

Extra over ? for T-intersection No

Extra over ? for mitred L-intersection No

? x ? x ?mm Hollow section spacer ?mm long with ends welded to No posts

? x ? x ?mm Hollow section post ?mm long with top welded to No framing and bottom welded to and including ? x ? x ?mm foot plate ? holed for bolt(s)

? x ? x ?mm Hollow section post ?mm long with flat closed top and No bottom welded to and including ? x ? x ?mm foot plate ? holed for bolt(s)

?mm ? expansion bolt No

?mm ? expansion anchor with loose bolt No

Welded balustrading to ?

Balustrading to walkway of ? x ?mm flat section continuous top rail, ? kg x ?mm flat section continuous bottom rail, ? x ?mm ? section intermediate balusters at ?mm centres between top and bottom rails and ? x ?mm ? section posts at approximately ?mm centres each with ? x ? x ?mm flat section base plate bolted to concrete (bolts elsewhere)

Page 130: Model Bill

Raking balustrading to staircase No ? of ? x ?mm flat section kg continuous top rail, ? x ?mm flat section continuous bottom rail, ? x ?mm ? section intermediate balusters at ?mm centres between top and bottom rails and ? x ?mm ? section posts at approximately ?mm centres each with ? x ? x ?mm flat section base plate bolted to concrete (bolts elsewhere)

? welded and bolted patent balustrading to ?

?mm Diameter continuous pipe top and bottom rails m

Extra over ? for 90 degree bend No

Extra over ? for 135 degree bend No

Extra over ? for straight end closure piece No

Extra over ? for 45 degree angle end closure piece No

Extra over ? for tube type end bracket No

?mm Diameter type ? stanchion ?mm long No

?mm ? expansion bolt No

?mm ? expansion anchor with loose bolt No

? welded and bolted patent balustrading to ?

Horizontal balustrading ?mm high of ?mm diameter continuous pipe m top and bottom rails and ?mm diameter type ? stanchions at average ?mm centres bolted to ? with ? ? bolts

Raking balustrading ?mm high of ?mm diameter continuous pipe top m and bottom rails and ?mm diameter type ? stanchions at average ?mm centres bolted to ? with ? ? bolts

Extra over ? for curved L-intersection of horizontal balustrading No

Extra over ? for ramped intersection of horizontal and raking No balustrading

Extra over ? for straight end closure piece No

Extra over ? for 45 degree angle end closure piece No

GLAZED ALUMINIUM BALUSTRADES

? (Black ?) anodised aluminium and structural glass balustrading to ?

? epoxy powder coated aluminium and structural glass

Page 131: Model Bill

balustrading to ?

?mm Diameter type ? handrails to suit ?mm glass m

? x ?mm Type ? handrails to suit ?mm glass m

Extra over ? for flat closed end No

Extra over ? for rounded closed end No

Extra over ? for ramp or knee No

Extra over ? for mitred L-intersection No

? x ? x?mm Channel section bottom rails fixed to concrete including m brackets, expansion bolts, etc

Extra over ? for closed end No

Extra over ? for mitred L-intersection No

?mm "?" toughened safety glass balustrade panels ?mm high and in m suitable lengths with bottom edge grouted with non-shrinking epoxy grout mixture into bottom rail and groove in concrete including neoprene setting blocks

?mm "?" toughened safety glass trapezium shaped balustrade panel No ?mm wide extreme and ?mm high with bottom edge grouted with non-shrinking epoxy grout mixture into bottom rail and groove in concrete including neoprene setting blocks

Polished edges to ?mm toughened glass m

Butt joints to ?mm toughened glass including polished edges and m silicone sealant

SUNDRY STEELWORK

SUNDRY GALVANIZED STEELWORK

Bolts

Bolts kg

?mm ? expansion bolt No

?mm ? expansion anchor with loose bolt No

Bearers to brick linings, lintels, etc

? x ? x ?mm Angle section bearers bolted to concrete kg

? x ? x ?mm Angle section bearers shot pinned to concrete at ?mm kg centres

Page 132: Model Bill

? x ? x ?mm Angle section bearers with ? x ? x ?mm flat section kg brackets welded on at 500mm centres and once holed for bolts

? x ? x ?mm Angle section brackets ?mm long ? holed for bolts kg

Hole through ?mm steel for bolt No

?mm ? expansion bolt No

Corner protectors

? x ?mm x ?Kg/m Channel section corner protectors in varying kg lengths with ?mm diameter bent lugs each ?mm girth welded on at ?mm centres including embedding in concrete

? x ?mm x ?Kg/m Channel section corner protectors in varying kg lengths with ? x ?mm flat section bent lugs each ?mm girth welded on at ?mm centres including embedding in concrete

? x ? x ?mm Angle section corner protectors in varying lengths with kg ?mm diameter bent lugs each ?mm girth welded on at ?mm centres including embedding in concrete

? x ? x ?mm Angle section corner protectors in varying lengths with kg ? x ?mm flat section bent lugs each ?mm girth welded on at ?mm centres including embedding in concrete

? x ? x ?mm Angle section corner protectors in varying lengths twice kg screwed to brickwork or concrete at ?mm centres

Extra over ? for mitred L-intersection No

Welded bearers to ?

Welded framing to ?

? x ?mm Flat section bearers kg

? x ?mm Flat section framing kg

? x ? x ?mm Angle section bearers kg

? x ? x ?mm Angle section framing kg

Bolts kg

? x ? x ?mm Hollow section bearers m

? x ? x ?mm Hollow section framing m

?mm Diameter ?mm thick pipe bearers m

?mm Diameter ?mm thick pipe framing m

Page 133: Model Bill

Extra over ? for rounded end No

Extra over ? for flat closed end No

Extra over ? for rounded closed end No

Extra over ? for L-intersection No

Extra over ? for mitred L-intersection No

Extra over ? for T-intersection No

? x ? x ?mm Base plate ? holed for bolts and welded on No

? x ? x ?mm Angle section cleat ?mm long once holed for bolt and No welded on

L-shaped bracket of ? x ?mm flat section ?mm girth once bent across No flat and ? holed for bolt(s)

? x ? x ?mm Shoe for end of roof timber of ? x ?mm flat section No L-shaped bracket ?mm girth with ? x ? x ?mm splay cut side plates welded to both sides and ? holed for bolts

L-shaped bracket formed of ? x ? x ?mm angle section ?mm girth No mitred and welded at angle and ? holed for bolts

Triangular shaped bracket formed of ? x ? x ?mm angle section ?mm No girth mitred and welded at angles and ? holed for bolts

Triangular shaped bracket formed of ? x ? x ?mm hollow section ?mm No girth mitred and welded at angles and ? holed for bolts

? x ? X ?mm Angle section frame for ? x ?mm access panel mitred No and welded at angles and ? holed for bolts

Hole through ?mm steel for bolt No

?mm ? expansion bolt No

Floor duct covers

?mm "Vastrap" plate duct covers in approximately ?mm widths and kg suitable lengths laid loose in framing

? x ? x ?mm Angle section framing with ? x ?mm flat section bent kg lugs each ?mm girth welded on at ?mm centres including embedding in concrete

Extra over ? for mitred L-intersection No

Extra over ? for T-intersection No

Page 134: Model Bill

? x ? x ?mm Angle section intermediate bearers ?mm long with two ? kg x ? x ?mm end plates each once slot holed for bolt and welded on

Battison galvanized pressed steel kerbing including sleeved joints, m corner pieces and anchor lugs embedded in concrete

Battison galvanized pressed steel kerbing including sleeved joints, m corner pieces and anchor lugs shot pinned to concrete

25mm Diameter finger hole through ?mm steel No

?mm ? expansion bolt No

Welded cat-walks in pipe ducts

? x ?mm Flat section bearers bolted to walls kg

? x ? x ?mm Angle section bearers bolted to walls kg

? x ? x ?mm Angle section bearers ?mm long with two ? x ? x ?mm kg end plates each ? holed for bolts and welded on

? x ? x ?mm Angle section framing welded to bearers kg

Extra over ? for mitred L-intersection No

? x ? x ?mm Welded mesh flooring of ?mm wide panels in suitable m2 lengths spot welded to framing

? type ? grille flooring of ?mm wide unbanded panels with ? x ?mm m2 bearer bars, in suitable lengths spot welded to framing

? type ? grille flooring of ?mm wide banded panels with ? x ?mm m2 bearer bars, in suitable lengths spot welded to framing

? type ? non-slip raised dimple grille flooring of ?mm wide banded m2 panels with ? x ?mm bearer bars, in suitable lengths spot welded to framing

Hole through ?mm steel for bolt No

?mm ? expansion bolt No

Welded cat-ladder ?mm wide and ?mm high to ?

? x ?mm Flat section stringers kg

Extra over ? for mitred L-intersection No

Extra over ? for bend across edge No

Extra over ? for bend across edge to ?mm internal radius No

?mm Diameter rungs ?mm long with ends welded to stringers kg

Page 135: Model Bill

? x ? x ?mm Fixing plate ? holed for bolt(s) and welded on No

? x ?mm Flat section bracket ?mm girth once bent across flat, once No holed for bolt and welded on

?mm External diameter ?mm thick pipe rung ?mm long with ends No welded to stringers

Alternatively

Welded cat-ladder ?mm wide and ?mm high to ? formed of ? x ?mm kg flat section stringers and ?mm diameter rungs ?mm long at approximately ?mm centres including flat and angle section connections

WELDED SCREENS, GATES, ETC

Screens and gates to ?

50 x 2,5mm Galvanized diamond mesh covering in approximately ?m m2 high panels tied with 1,6mm galvanized binding wire to framing

50 x 2,5mm Plastic coated galvanized diamond mesh covering in m2 approximately ?m high panels tied with 1,6mm plastic covered binding wire to framing

? x ? x ?mm ? mesh covering in approximately ?mm high panels spot m2 welded to framing

? x ?mm x ?Kg/m Channel section post ?m long with ? x ? x ?mm kg base plate ? holed for bolts and welded on

?mm Diameter ?mm thick pipe rails, posts, etc m

Extra over ? for closed end No

Extra over ? for mitred and welded L-intersection No

Extra over ? for scribed and welded T-intersection No

L-shaped cleat formed of ? x ?mm flat section ?mm girth ? holed for No bolt(s) and welded on

? x ? x ?mm Hollow section post ?m long with closed top end and ? x No ? x ?mm base plate ? holed for bolts and welded on

?mm ? expansion bolt No

?mm ? expansion anchor with loose bolt No

Single gate ? x ?mm high of ? x ?mm flat section outer frame and ? x No ? x ?mm angle section inner frame welded to outer frame, filled in with ? expanded metal panel fixed all round to inner frame with ? x ?

Page 136: Model Bill

x ?mm angle section fixing beads bolted on with and including ?mm diameter bolts at ?mm centres and fitted with a pair of suitable hinges welded to post and lockable sliding bolt with keep in gate post

Single gate ? x ?mm high of ? x ? x ?mm hollow section frame filled No in with ? x ? x ?mm welded mesh welded to frame and fitted with a pair of suitable hinges welded to post and hasp and staple welded on

Single gate ? x ?mm high of ? x ? x ?mm hollow section frame and ? No x ? x ?mm hollow section horizontal middle rail filled in with ? x ? x ?mm hollow section vertical rails at ? centres and fitted with a pair of suitable hinges welded to post and with ears for padlock

Double gate ? x ?mm high, each leaf of ? x ? x ?mm hollow section No frame and ? x ? x ?mm hollow section horizontal middle rail filled in with ? x ? x ?mm hollow section vertical rails at ? centres and fitted with a pair of suitable hinges to each leaf bolted to wall with and including ? expansion bolts and with hasp and staple and ?mm drop bolt welded on

SUNDRY STAINLESS STEELWORK

SUNDRY CHROMIUM PLATED STEELWORK

SUNDRY ALUMINIUM WORK

? ? anodised aluminium cappings with sealed joints fixed to brickwork or concrete

Type ? wall cappings ?mm wide overall m

Extra over ? for mitred and sealed L-intersection No

? ? anodised aluminium

Type ? angle section corner protectors plugged to brickwork or m concrete

Extra over ? for mitred L-intersection No

PRESSED STEEL DOOR FRAMES

GALVANIZED PRESSED STEEL DOOR FRAMES

1,2mm Rebated frames suitable for half brick walls

1,2mm Rebated frames suitable for ? walls

1,2mm Double rebated frames suitable for half brick walls

1,2mm Double rebated frames suitable for one brick walls

1,2mm Double rebated frames suitable for ? walls

Page 137: Model Bill

1,6mm Rebated frames suitable for one brick walls

1,6mm Rebated frames suitable for ? walls

?mm Rebated frames suitable for ? walls with ? brass butt hinges per door leaf

?mm Rebated frames suitable for ? walls with ? brass butt hinges per door leaf and ? brass butt hinges per fanlight

?mm Double rebated frames suitable for ? walls with ? brass butt hinges per door leaf

?mm Double rebated frames suitable for ? walls with ? brass butt hinges per door leaf and ? brass butt hinges per fanlight

?mm Hollow grooved frames suitable for ? walls for swing doors (no hinges)

?mm Rebated frames suitable for ? walls to jambs, head and threshold of openings

?mm Double rebated frames suitable for ? walls to jambs, head and threshold of openings

Frame for door ? x ?mm high No

Frame for double door ? x ?mm high No

Frame for door ? x ?mm high and fixed fanlight ?mm high No

Frame for double door ? x ?mm high and fixed fanlight ?mm high No

Frame for door ? x ?mm high and fixed fanlight ?mm high with No standard pressed steel glazing beads on one side of fanlight

Frame for double door ? x ?mm high and fixed fanlight ?mm high No with standard pressed steel glazing beads on one side of fanlight

Frame for door ? x ?mm high and hinged fanlight ?mm high No

Frame for double door ? x ?mm high and hinged fanlight ?mm high No

Preparation of frames for fixing of ironmongery

Arm of door closer No

PRESSED STEEL CUPBOARD DOOR FRAMES

GALVANIZED PRESSED STEEL CUPBOARD DOOR FRAMES

Standard cupboard door frames

Page 138: Model Bill

Type ? frame ? x ?mm high overall No

Purpose made rebated cupboard door frames

Frame for door ? x ?mm high No

Frame for double door ? x ?mm high No

Frame for door ? x ?mm high and door ?mm high above transom No

Frame for double door ? x ?mm high and double door ? x ?mm high No above transom

PRESSED STEEL COMBINATION DOORS AND FRAMES

GALVANIZED PRESSED STEEL COMBINATION DOORS AND FRAMES

? doors

Door ? x ?mm high with rebated frame suitable for ? wall and with ? No mortice lock

Double door ? x ?mm high with rebated frame suitable for ? wall and No with ? mortice lock

PRESSED STEEL TRANSFORMER ROOM DOORS AND FRAMES

GALVANIZED PRESSED STEEL TRANSFORMER ROOM DOORS AND FRAMES

? doors

Type ? door ? x ?mm high with rebated frame suitable for ? wall No

Type ? double door ? x ?mm high with rebated frame suitable for ? No wall

Door ? x ?mm high with ? x ?mm high louvred ventilation panel and No rebated frame suitable for ? wall

Double door ? x ?mm high with each leaf with ? x ?mm high louvred No ventilation panel and rebated frame suitable for ? wall

STEEL WINDOWS, DOORS, ETC

GALVANIZED STEEL WINDOWS, DOORS, ETC

Standard residential windows

Standard school windows

Page 139: Model Bill

Standard industrial windows

Standard ? windows with mesh burglar screens to opening sashes

Standard ? windows with mesh burglar screens to fixed lights and opening sashes

Standard ? windows with ? burglar bars to opening sashes

Standard ? windows with flyscreens

Standard ? composite windows

Purpose made ? windows

Purpose made ? windows with mesh burglar screens to opening sashes

Purpose made ? windows with ? burglar bars to opening sashes

Purpose made ? windows with ? x ?mm glazing beads

Window type ?, ? x ?mm high (?) No

Window as type ? but ? x ?mm high (?) No

Window ? x ?mm high with one fixed light (?) No

Window ? x ?mm high with one ? hung sash (?) No

Window ? x ?mm high with ? mullion(s) and ? fixed lights (?) No

Window ? x ?mm high with ? mullion(s), ? fixed light(s) and ? ? x No ?mm high ? hung sash(es) (?)

Window ? x ?mm high with ? transom(s), ? mullion(s), ? fixed No light(s) and ? ? x ?mm high ? hung sash(es) (?)

Window ? x ?mm high with ? transom(s), ? mullion(s), ? part No mullion(s) ?mm long, ? fixed light(s) and ? ? x ?mm high ? hung sash(es) (?)

Window ? x ?mm high with one fixed light filled in with ? pressed No steel louvres (?)

Steel glazing beads, coupling transoms, coupling mullions, etc

? x ?mm Standard glazing beads m

Standard ? section coupling mullions in varying lengths m

Standard ? section coupling transoms in varying lengths m

? x ?mm ? section coupling mullions in varying lengths m

Page 140: Model Bill

? x ?mm ? section coupling transoms in varying lengths m

? x ? x ?mm Hollow section coupling mullions in varying lengths m

?mm External diameter ?mm thick pipe coupling mullions in varying m lengths

? x ? x ?mm Hollow section mullion ?mm long with ? x ? x ?mm cap No and base plates each ? holed for bolts

?mm External diameter ?mm thick pipe mullion ?mm long with ? x ? No x ?mm cap and base plates each ? holed for bolts

Standard medium universal doors, sidelights, fanlights, etc

Standard medium universal doors, sidelights, fanlights, etc with ? x ?mm glazing beads

Purpose made medium universal doors, sidelights, fanlights, etc

Purpose made medium universal doors, sidelights, fanlights, etc with ? x ?mm glazing beads

Sidelight type ?, ? x ?mm high (?) No

Door type ?, ? x ?mm high (?) No

Double door type ?, ? x ?mm high (?) No

Sidelight ? x ?mm high with ? horizontal glazing bars and the bottom No pane ?mm high filled in with kicking plate (?)

Door ? x ?mm high side hung to open out with ? horizontal glazing No bars and lock box, the bottom pane ?mm high filled in with kicking plate, the door fitted with ? lock (?)

Double door ? x ?mm high side hung to open out, each leaf with ? No horizontal glazing bars, lock box and bottom panes ?mm high filled in with kicking plate, the door fitted with two barrel bolts and ? lock (?)

Door and sidelight ? x ?mm high overall, the sidelight ? x ?mm high No with ? horizontal glazing bars and bottom pane ?mm high filled in with kicking plate and the door ? x ?mm high with ? horizontal glazing bars, lock box and bottom pane ?mm high filled in with kicking plate, the door fitted with ? lock (?)

STEEL LOUVRE PANELS

GALVANIZED STEEL LOUVRE PANELS

? type ? louvre panels screwed into steel window frames

Panel ? x ?mm high No

Page 141: Model Bill

NATURAL ANODISED ALUMINIUM LOUVRE UNITS

? ANODISED ALUMINIUM LOUVRE UNITS

? type ? adjustable louvre units screwed into wooden frames

? type ? adjustable louvre units screwed into steel window frames

Louvre unit for ? x ?mm high opening including ?mm clear float glass No horizontal louvres

Louvre unit for ? x ?mm high opening including ?mm ? glass No horizontal louvres

Louvre unit for ? x ?mm high opening including ?mm ? glass vertical No louvres

ALUMINIUM WINDOWS, DOORS, ETC

User Note:

A detail specification is to be inserted as necessary

Note: Tenderers are referred to architect's drawings numbered ..... annexed to these bills of quantities/accompanying these bills of quantities for tender purposes

? ? anodised aluminium windows glazed with ?mm clear float glass and plugged to brickwork or concrete

? ? anodised aluminium windows glazed with ?mm ? laminated safety glass and plugged to brickwork or concrete

? ? anodised aluminium windows glazed with ?mm clear float glass and with adjustable louvre units with ?mm clear float glass horizontal louvres and plugged to brickwork or concrete

? epoxy powder coated aluminium windows glazed with ?mm clear float glass and plugged to brickwork or concrete

? epoxy powder coated aluminium windows glazed with ?mm ? laminated safety glass and plugged to brickwork or concrete

? ? anodised aluminium doors, sidelights and fanlights glazed with ?mm ? laminated safety glass and plugged to brickwork or concrete

Window ? x ?mm high (?) (drawing No ?) No

Page 142: Model Bill

Door ? x ?mm high with ? lock and one pair of ?mm ? handles (?) No (drawing No ?)

Double door ? x ?mm high with ? ? action floor springs, ? lock and No two pairs of ?mm ? handles (?) (drawing No ?)

SHOWER CUBICLE DOORS

? ? anodised aluminium shower cubicle doors with sliding gear, cleats, stops, etc and ?mm toughened obscure safety glass plugged to tiled walls

Sliding door ? x ?mm high No

Sliding door in ? leaves, ? x ?mm high overall No

PRESSED STEEL GARAGE DOORS

GALVANIZED PRESSED STEEL GARAGE DOORS

? tip-up doors fixed to brickwork or concrete

Tip-up door for ? x ?mm high opening No

STEEL ROLLER SHUTTERS ETC

? roller shutters fixed to brickwork or concrete

? epoxy powder coated roller shutters fixed to brickwork or concrete

Manual push-up slatted roller shutter for ? x ?mm high opening No

Chain operated slatted roller shutter for ? x ?mm high opening No

Soffit fixed crank operated slatted roller shutter for ? x ?mm high No opening

Crank operated slatted roller shutter for ? x ?mm high opening No

Electrically operated slatted roller shutter for ? x ?mm high opening No

Class B fire resistant ? operated slatted roller shutter for ? x ?mm high No opening

? roller grilles fixed to brickwork or concrete

? epoxy powder coated roller grilles fixed to brickwork or concrete

? pattern ? operated roller grille for ? x ?mm high opening No

Page 143: Model Bill

? Sliding panel doors fixed to brickwork or concrete

Slideover ? operated panel door for ? x ?mm high opening No

STEEL STRONGROOM DOORS, VENTILATORS, ETC

? Strongroom doors etc suitable for 230mm walls fixed to brickwork or concrete

Single ended strongroom ventilator No

Double ended strongroom ventilator No

? record room door and frame ? x ?mm high overall with a mass of No ?kg

? strongroom door and frame ? x ?mm high overall with a mass of No ?kg

? anti-explosive strongroom door and frame ? x ?mm high overall No with a mass of ?kg

? heavy duty anti-explosive strongroom door and frame ? x ?mm No high overall with a mass of ?kg

SECURITY PAYROLL WINDOWS

? security payroll windows suitable for 230mm walls fixed to brickwork or concrete

? window ? x ?mm high No

ROOF LIGHTS

? type

Airtight dome to suit ? x ?mm opening formed of 5mm thick U-95 No tinted acrylic perspex with aluminium kerb bolted to concrete with and including expansion bolts

Double skin dome to suit ? x ?mm opening formed of 5mm thick clear No acrylic perspex inner skin and 5m thick U-95 tinted acrylic perspex outer skin with aluminium kerb bolted to concrete with and including expansion bolts

Barrel vault type ? to suit ? x ?mm opening formed of 5mm thick ? No tinted acrylic perspex including ? anodised aluminium framing, glazing bars, etc bolted to concrete with and including expansion bolts

BILL ?

PLASTERING

Page 144: Model Bill

SCREEDS

Screeds on concrete

Screeds wood floated on concrete

?:? Cement plaster screeds wood floated on concrete

?:? Cement plaster screeds steel trowelled on concrete

Screeds with compressive strength of ? MPa steel trowelled on concrete

CEMENT RENDER

Cement render on concrete

Untinted ?:? cement plaster render steel trowelled on concrete

GRANOLITHIC

Untinted granolithic on concrete

Untinted granolithic waterproofed with ? waterproofing additive on concrete

Untinted granolithic hardened with ?kg of ? hardener per 50kg of cement on concrete

Black granolithic on concrete

Green granolithic on concrete

?mm Thick on floors and landings m2

?mm Thick on floors in sunk/raised panels m2

?mm Thick on floors on waterproofing membrane m2

?mm Thick on floors incorporating underfloor heating coils m2

Average ?mm thick on floors to falls m2

Average ?mm thick on floors to falls and currents m2

?mm Thick on walls m2

?mm Thick on circular walls m2

?mm Thick on projecting and isolated columns m2

?mm Thick on treads and risers of stairs m2

Page 145: Model Bill

?mm Thick on treads and risers of stairs including reedings m2

?mm Thick on narrow widths m2

? x ?mm Deep segmental channel formed in floor finish. m

?mm Thick on top and side(s) of kerbs ?mm girth m

Skirting ?mm high m

Skirting ?mm high stepped over treads and risers m

Raking skirting average ?mm high stepped over treads and risers m

Sundries

Fixing in position steel underfloor cable ducts ? x ?mm deep overall m including levelling by means of wedges and mortar packings, securing in position whilst screeding and working screed around and under ducts and junction boxes to finish level with floor finish (ducts supplied and placed roughly in position by others)

INTERNAL PLASTER

Compo plaster on brickwork

Compo plaster on concrete

Cement plaster on brickwork

Cement plaster on concrete

Gypsum skim plaster on brickwork

Gypsum skim plaster on concrete

Two coat plaster with gypsum finish on brickwork

Two coat plaster with gypsum finish on concrete

Rough-cast plaster on brickwork

Rough-cast plaster on concrete

Fine rough-cast plaster on brickwork

Fine rough-cast plaster on concrete

EXTERNAL PLASTER

Compo plaster on brickwork

Page 146: Model Bill

Compo plaster on concrete

Cement plaster on brickwork

Cement plaster on concrete

Cement plaster of uniform appearance and consistent colour thoughout wood floated on brickwork (no paint or other decoration)

Rough-cast plaster on brickwork

Rough-cast plaster on concrete

Fine rough-cast plaster on brickwork

Fine rough-cast plaster on concrete

On walls m2

On walls in sunk/raised panels m2

On walls between timber grounds (area of grounds not deducted) m2

On circular walls m2

On projecting and isolated columns m2

On ceilings m2

On raking soffits of stairs m2

On projecting and isolated beams m2

On narrow widths m2

On sloping top, edge and projecting soffit of sills ?mm girth m

On sloping top, ? edge(s) and ? projecting soffit(s) of copings ?mm m girth

On top, edge and projecting soffit of nibs ?mm girth m

On side(s) and front edge of surrounds ?mm girth m

Horizontal moulding ? x ?mm projection and ?mm girth m

End to moulding ?mm girth No

Mitre to moulding ?mm girth No

User note:

Ends, mitres and intersections shall only be given where the moulding

Page 147: Model Bill

exceeds 300mm girth

TERRAZZO

User note:

If and when terrazzo is to be included in the bill of quantities all work is to be given in accordance with the foregoing principles

SPECIALIST PLASTER WALL COVERINGS

All specialist plaster wall coverings are to be executed in strict accordance with the manufacturer's instructions

?mm Thick "Gamma Zenith ?" pure acrylic plasticized coating with trowel on finish on plaster

?mm Thick "Gamma Zenith ?" pure acrylic plasticized coating with stone finish on plaster

?mm Thick "Marmoran Trowel-on" PVC resin bonded coating on plaster

2mm Thick "Marmoran" PVC resin bonded coating with 3,2mm "Stone Finish" on plaster

2mm Thick "Marmoran" PVC resin bonded coating with 3,2mm "Stone Finish" with acrylic glaze coat on plaster

On walls m2

On circular walls m2

On projecting and isolated columns m2

On ceilings m2

On raking soffits of stairs m2

On projecting and isolated beams m2

On narrow widths m2

AIR GRATINGS

235 x 157mm Cast plaster or white plastic plain pattern air grating No fixed flush with plaster face

CORNER PROTECTORS, DIVIDING STRIPS, ETC

Page 148: Model Bill

Type ? galvanised steel corner protectors fixed to brickwork or m concrete

? x ?mm Flat section brass dividing strips between different floor m finishes

TYPE ? METAL LATHING

? x ?mm Mesh ?kg/m2 expanded metal lathing fixed to timber m2 brandering to ceilings (brandering elsewhere)

? x ?mm Mesh ?kg/m2 expanded metal lathing strips ?mm wide bent m to shape and fixed along both edges to brickwork or concrete

BILL ?

TILING

SUPPLEMENTARY PREAMBLES

Descriptions

Unless described as "fixed with adhesive to plaster (plaster elsewhere)" descriptions of tiling on brick or concrete walls, columns, etc shall be deemed to include 1:4 cement plaster backing and descriptions of tiling on concrete floors etc shall be deemed to include 1:3 plaster bedding

WALL TILING

152 x 152 x 5mm White glazed ceramic tiles on brickwork

including cement plaster ? backing

152 x 152 x 5mm White glazed ceramic tiles on concrete including

cement plaster ? backing

152 x 152 x 5mm White glazed ceramic tiles fixed with adhesive to plaster (plaster elsewhere)

? x ? x 5mm ? group ? colour glazed ceramic tiles flush pointed

with tinted jointing compound on brickwork including cement

plaster ? backing

Page 149: Model Bill

? x ? x 5mm ? group ? colour glazed ceramic tiles flush pointed

with tinted jointing compound on concrete including cement plaster

? backing

? x ? x 5mm ? group ? colour glazed ceramic tiles fixed with adhesive to plaster (plaster elsewhere) and flush pointed with tinted jointing compound

? x ? x ?mm ? No ? un?glazed ceramic tiles flush pointed with

tinted jointing compound on brickwork including cement plaster ?

backing

? x ? x ?mm ? No ? un?glazed ceramic tiles flush pointed with tinted jointing compound on concrete

? x ? x ?mm ? No ? un?glazed ceramic tiles fixed with adhesive to plaster (plaster elsewhere) and flush pointed with tinted jointing compound

On walls m2

On walls circular exceeding 300mm radius m2

On walls circular not exceeding 300mm radius m2

On walls in isolated panels, splashbacks, etc m2

On projecting and isolated columns m2

On piers and pilasters m2

On narrow widths m2

Circular cutting m

Fair exposed cutting and fitting around rectangular handrail etc not No exceeding ?mm girth

Fair exposed cutting and fitting around rectangular handrail etc No exceeding ?mm and not exceeding ?mm girth

Page 150: Model Bill

Fair exposed cutting and fitting around pipe not exceeding ?mm No internal diameter

Fair exposed cutting and fitting around pipe exceeding ?mm and not No exceeding ?mm internal diameter

FLOOR TILING

? x ? x ?mm ? No ? un?glazed floor tiles on ?mm bedding on concrete and flush pointed with tinted waterproof jointing compound

? x ? x ?mm ? No ? un?glazed floor tiles on ?mm bedding on concrete and flush pointed with epoxy mortar

? x ? x ?mm ? No ? un?glazed floor tiles fixed with adhesive to bedding (bedding elsewhere) and flush pointed with tinted waterproof jointing compound

? x ? x ?mm ? No ? un?glazed floor tiles fixed with adhesive to bedding (bedding elsewhere) and flush pointed with epoxy mortar

On floors and landings m2

On narrow widths m2

Circular cutting m

On raking and stepped outer edges of stairs average ?mm wide m

On margins ?mm wide of stretcher course tiles m

On sills ?mm wide of stretcher course tiles laid flat m

On sills ?mm wide of stretcher course tiles laid sloping m

On risers ?mm high of stretcher course tiles m

On risers ?mm high of cut soldier course tiles m

On treads ?mm wide of No ? nosing tiles with stretcher course tiles m behind

On treads ?mm wide of No ? nosing tiles with cut header course tiles m behind

Skirting ?mm high of No ? skirting tiles m

Page 151: Model Bill

Skirting ?mm high of No ? skirting tiles stepped over treads and risers m

Extra for end tile No

Extra for internal corner tile No

Extra for external corner tile No

Fair exposed cutting and fitting around rectangular baluster etc not No exceeding ?mm girth

Fair exposed cutting and fitting around rectangular baluster etc No exceeding ?mm and not exceeding ?mm girth

Fair exposed cutting and fitting around pipe not exceeding ?mm No internal diameter

Fair exposed cutting and fitting around pipe exceeding ?mm and not No exceeding ?mm internal diameter

CHANNELS

Vaal white glazed fireclay block channels bedded and jointed in 1:3 cement mortar and pointed with flush joints in 1:3 white cement mortar

? x ?mm Block channels m

Extra over block channels for

Fair end No

Stopped end No

Angle No

T-intersection No

X-intersection No

Outlet No

Stopped end with outlet No

Page 152: Model Bill

SUNDRIES

? x ?mm Access panel of 6mm tempered hardboard with ? ceramic No tiles fixed with adhesive, fitted flush with tile face and screwed with ? chromium plated dome-capped screws to and including 38 x 38mm sawn softwood framing plugged to wall

TOILET PAPER HOLDERS ETC

Johnson white glazed ceramic

Johnson colour glazed ceramic

? white glazed ceramic

? colour glazed ceramic

? x ?mm Type ? semi-recessed toilet paper holder No

? x ?mm Type ? recessed toilet paper holder No

? x ?mm Type ? semi-recessed soap dish No

? x ?mm Type ? recessed soap dish No

? x ?mm Type ? recessed soap dish with hand grip No

? x ?mm Type ? foot rest No

BILL ?

PLUMBING AND DRAINAGE (PROVISIONAL)

SUPPLEMENTARY PREAMBLES

Polycop polypropylene pipes:

Polypropylene pipes 54mm diameter and under shall be seamless copper coloured class 16 pipes jointed with "Fast-fuse" heat welded thermoplastic or brass compression fittings as designed for use with copper pipes as stated

Pipes shall be firmly fixed to walls etc with coloured nylon snap-in pipe clips with provision for accommodating thermal movement and jointed and fixed strictly in accordance with the manufacturer's instructions

All pipe diameters are nominal external

Polylink polypropylene pipes:

Polypropylene pipes 63mm diameter and over shall be class 12 pipes jointed with cast iron "Supraclamp" running joints

Page 153: Model Bill

Fusion welded bends, once or twice mitred as necessary, and tees shall be factory manufactured

Fusion welded bends and tees shall include jointing to pipes with PVC rubber ring double Z joint couplers

Branch tees shall include flanged and bolted joints to "Polycop" branch pipes in addition and for brass compression male iron to copper straight couplers

Reducers shall include jointing to pipes with PVC rubber ring double Z joint couplers and reducers shall be of sufficient overall length to accommodate same

All pipes shall be jointed and fixed strictly in accordance with the manufacturer's instructions

All pipe diameters are nominal external

Concrete pipes:

Pipes shall be jointed with ogee joints with rubber collars or socket and spigot joints with rubber rings

Vitrified clay pipes:

Pipes shall rest on solid ground and, where necessary, pockets of sufficient size shall be cut around joints to enable the jointing to be properly performed or, alternatively, pipes shall be bedded full length on and including unreinforced concrete laid in a semi-dry state immediately before pipes are laid

Sewer and drainage pipes and fittings shall be jointed and sealed with butyl rubber rings

uPVC pipes and fittings:

Soil, waste and vent pipes and fittings shall be solvent weld jointed

uPVC pressure pipes and fittings:

Pipes for water supply shall be of the class stated

Pipes of 40mm diameter and smaller shall be plain ended with solvent welded uPVC loose sockets and fittings

Pipes of 50mm diameter and greater shall have sockets and spigots with push in type integral rubber ring joints. Bends shall be uPVC and all other fittings shall be cast iron, all with similar push-in type joints

Copper pipes:

Page 154: Model Bill

Pipes shall be hard drawn and half-hard pipes of the class stated. Class 0 (thin walled hard drawn) pipes shall not be bent. Class 1 (thin walled half-hard), class 2 (half-hard) and class 3 (heavy walled half-hard) pipes shall only be bent with benders with inner and outer formers. Fittings to copper waste, vent and anti-syphon pipes, capillary solder fittings and compression fittings shall be "Cobra Watertech" type. Capillary solder fittings shall comply with ISO 2016. Only compression fittings shall be used in walls or in ground

Fixing of pipes

Unless specifically otherwise stated, descriptions of pipes shall be deemed to include fixing to walls etc, casting in, building in or suspending not exceeding 1m below suspension level

Lead pipes and fittings

All soldered joints shall be wiped and brass unions shall be used for jointing lead to steel

Reducing fittings

Where fittings have reducing ends or branches they are described as "reducing". In the case of pipes with diameters not exceeding 60mm only the largest end or branch size is given. Should the contractor wish to use other fittings and bushes or reducers he may do so on the understanding that no claim in this regard will be entertained. In the case of pipes with diameters exceeding 60mm all sizes are given and no claim for extra bushes, reducers, etc will be entertained

Wire gratings

Descriptions of gutter outlets etc shall be deemed to include wire balloon gratings

Septic tanks

Descriptions of septic tanks shall be deemed to include excavation, bedding and jointing, concrete base slabs, jointing to drains and backfilling, compaction, etc all in accordance with the manufacturer's instructions

Exposed concrete surfaces

Exposed surfaces of concrete stormwater channels, cover slabs, inspection eye marker slabs, gulley tops, cleaning eye tops, catchpits, inspection chambers, etc shall be finished smooth with plaster

Excavations

No claim for rock excavation will be entertained unless the contractor has timeously notified the quantity surveyor thereof prior to

Page 155: Model Bill

backfilling

Soft rock and "hard rock" shall be as defined in "Earthworks"

Laying, backfilling, bedding, etc. of pipes

Pipes shall be laid and bedded and trenches shall be carefully backfilled in accordance with manufacturers' instructions

Where no manufacturers' instructions exist pipes shall be laid in accordance with clauses 5.1 and 5.2 of each of the following:

SABS 1200 L : Medium-pressure pipelines

LD : Sewers

LE : Stormwater drainage

Pipe trenches etc shall be backfilled in accordance with clauses 3, 5.5, 5.6, 5.7 and 7 of SABS 1200

DB : Earthworks (Pipe trenches)

Pipes shall be bedded in accordance with clauses 3.1 to 3.4.1, 5.1 to 5.3 and 7 of SABS 1200

LB : Bedding (Pipes).

Unless otherwise described bedding of rigid pipes shall be class B bedding

Flush pans

Flush pans shall have straight or side outlets and "P" or "S" traps as No necessary

Stainless steelbasins, sinks, wash troughs, urinals, etc.

Units shall have standard aprons on all exposed edges and tiling keys against walls where applicable

Waste unions

Descriptions of waste unions shall be deemed to include rubber or vulcanite plugs and chains fixed to fittings

Steel sectional water tanks

Tanks shall comply with SABS CKS 114

Densyl petrolatum anti-corrosion tape as manufactured by Denso SA (Pty) Ltd.

Pipes to be taped shall be coated with the appropriate primer and the

Page 156: Model Bill

tape shall be applied with minimum 15mm lap per spiral unless otherwise described

Couplings and fittings to pipes shall be taped in strict accordance with the manufacturer's instructions including all mastic, tape, "Layflat" sheeting, securing of same, etc

User note:

Dependent on soil or environmental conditions laps may require to be increased to a maximum of 55% (which results in a double layer)

SUBSOIL DRAINAGE

Excavation not exceeding 2m deep for drain trenches m3

Backfilling to drain trenches compacted to ?% Mod AASHTO density m3

?mm Crushed stone encasing to pipes m3

? Geofabric filter blanket wrapped around agricultural pipes with m2 50mm side and 300mm end laps including stitching

? Geofabric filter blanket wrapped around stone encasing with m2 150mm side and 300mm end laps including stitching

?mm Slotted uPVC agricultural pipes laid in stone encasing m

?mm "Santar" perforated pitch fibre pipes laid in stone encasing m

Extra for ?mm capped end No

Extra for ?mm bend No

Extra for ?mm junction No

?mm Slotted uPVC agricultural pipes laid in and including trenches m not exceeding 1m deep including ?mm crushed stone encasing size ? x ?mm and ? geofabric filter blanket wrapped around encasing with 150mm side and 300mm end laps including stitching

?mm Slotted uPVC agricultural pipes laid in and including trenches m exceeding ?mm and not exceeding ?mm deep including ?mm crushed stone encasing size ? x ?mm and ? geofabric filter blanket wrapped around encasing with 150mm side and 300mm end laps including stitching

?mm "Santar" perforated pitch fibre pipes laid in and including m trenches not exceeding 1m deep including ?mm crushed stone encasing size ? x ?mm and ? geofabric filter blanket wrapped around encasing with 150mm side and 300mm end laps including stitching

Page 157: Model Bill

?mm "Santar" perforated pitch fibre pipes laid in and including m trenches exceeding ?mm and not exceeding ?mm deep including ?mm crushed stone encasing size ? x ?mm and ? geofabric filter blanket wrapped around encasing with 150mm side and 300mm endlaps including stitching

20mm Mesh galvanised wire netting stopper in end of ?mm pipe No

STORMWATER CHANNELS

Precast concrete channels

? precast concrete channels

460 x 170mm Channels with 310 x 110mm deep segmental channel m

? x ?mm Channels with ? x ?mm deep segmental channel m

Extra for angles, intersections, ends, dressing into sides of catchpits, No etc

? x ?mm Channel ?mm long with ? x ?mm deep segmental channel, No one open end and one stopped end

STORMWATER DRAINAGE

SOIL DRAINAGE

DUCTS FOR ELECTRICAL AND TELEPHONE CABLES ETC

Excavation not exceeding 2m deep for drain trenches m3

Backfilling to drain trenches m3

Backfilling to drain trenches compacted to ?% Mod AASHTO density m3

?mm Selected sand filling from the excavations in bedding under and m3 filling around pipes

?mm Sand filling supplied by the contractor in bedding under and m3 filling around pipes

?mm Crushed stone bedding under pipes m3

Unreinforced concrete bedding under pipes m3

Fibre-cement channels

Vitrified clay channels

uPVC channels

Page 158: Model Bill

Santar pitch fibre channels

Class 100D concrete pipes

Class ? concrete pipes

Everite class T fibre-cement pipes

User note:

These fibre-cement pipes are used only for ducts for cables and are only manufactured in Brackenfell

Fibre-cement series 4 pipes with sewer couplings

Vitrified clay pipes

Cast iron pipes

Cast iron plain ended pipes with "Besaans du Plessis type SSN" couplings

Heavy duty cast iron pipes

uPVC pipes

uPVC class ? pipes

Santar class 1 pitch fibre pipes

? pipes laid in class ? bedding

?mm Half round channels in bottoms of inspection chambers m

User note:

Channels are only measurable where inspection chambers are measured out in detail i.e. not measurable when in number

?mm Pipes vertically or ramped to cleaning eyes etc (no excavation) m

?mm Pipes laid in trenches (trenches elsewhere) m

Set of two ?mm pipes laid in trenches (trenches elsewhere) m

Set of ? ?mm pipes laid in trenches (trenches elsewhere) m

Set of ? ?mm pipes in two tiers, one on top of the other, laid in m trenches (trenches elsewhere)

Page 159: Model Bill

?mm Pipes laid in and including trenches not exceeding 1m deep m

?mm Pipes laid in and including trenches exceeding ?m and not m exceeding ?m deep

Set of two ?mm pipes laid in and including trenches not exceeding 1m m deep

Set of ? ?mm pipes laid in and including trenches not exceeding 1m m deep

Set of ? ?mm pipes in two tiers, one on top of the other, laid in and m including trenches not exceeding 1m deep

Extra over fibre-cement channels for fittings

Extra over vitrified clay channels for fittings

Extra over uPVC channels for fittings

Extra over pitch fibre channels for fittings

Extra over class T fibre-cement pipes for fittings

Extra over fibre-cement series 4 pipes for fittings

Extra over vitrified clay pipes for fittings

Extra over cast iron pipes for fittings

Extra over cast iron plain ended pipes for fittings with "Besaans du Plessis type SSN" couplings

Extra over heavy duty cast iron pipes for fittings

Extra over uPVC pipes for fittings

Extra over uPVC class ? pipes for fittings

Extra over pitch fibre pipes for polypropylene fittings

?mm End cap No

?mm Taper channel No

?mm Taper pipe No

?mm Bend No

?mm Junction No

? x ?mm Reducing junction No

Page 160: Model Bill

?mm Access pipe No

?mm Access bend No

?mm Access junction No

? x ?mm Access reducing junction No

?mm Access double junction No

? gulleys

?mm Gulley not exceeding ?mm deep No

?mm Gulley exceeding ?mm and not exceeding ?mm deep No

?mm Dished gulley not exceeding ?mm deep No

?mm Dished gulley exceeding ?mm and not exceeding ?mm deep No

Inspection chambers (covers elsewhere) No

Sumps, catchpits, inspection chambers, etc (gratings and covers No elsewhere)

User note:

Where inspection chambers are measured in number they are classified in depths not exceeding 750mm to invert and thereafter in stages of 250mm

Where catchpits, junction boxes, stopcock boxes, etc are measured in number they are classified in depths in stages of 250mm to invert

Junction box ? x ?mm and not exceeding ?mm deep internally No

Junction box ? x ?mm and exceeding ?mm and not exceeding ?mm No deep internally

Rainwater sump ? x ?mm and not exceeding ?mm deep internally No

Rainwater sump ? x ? and exceeding ?mm and not exceeding ?mm No deep internally

Catchpit ? x ?mm and not exceeding 750mm deep internally No

Catchpit ? x ?mm and exceeding ?mm and not exceeding ?mm deep No internally

Inspection chamber ? x ?mm and not exceeding 750mm deep No

Page 161: Model Bill

internally

Inspection chamber ? x ?mm and exceeding ?mm and not exceeding No ?mm deep internally

Inspection chamber ? x ?mm and exceeding ?mm and not exceeding No ?mm deep internally with the lower 1,5m depth increased to ? x ?mm internally and 150mm precast concrete reducer slab over enlarged bottom portion

Precast concrete circular inspection chambers (covers elsewhere)

Inspection chamber ?mm diameter and not exceeding 750mm deep No internally

Inspection chamber ?mm diameter and exceeding ?mm and not No exceeding ?mm deep internally

Inspection chamber ?mm diameter and exceeding ?mm and not No exceeding ?mm deep internally with the lower 1,5m depth increased to ?mm diameter and 150mm precast concrete reducer slab over enlarged bottom portion

Covers etc

Gratings, covers, etc

?mm Diameter ?mm thick precast concrete removable cover No

? x ?mm x ?kg Cast iron dished grating and frame No

? x ?mm x ?kg Type ? cast iron dished grating and frame No

? x ?mm x ?kg Cast iron single seal manhole cover and frame No

450 x 600mm x 68kg Type 9D cast iron single seal manhole cover No and frame

? x ?mm x ?kg Type ? cast iron single seal manhole cover and frame No

? x ?mm x ?kg Cast iron double seal manhole cover and frame No

? x ?mm x ?kg Type ? cast iron double seal manhole cover and frame No

?mm Diameter ?kg type ? cast iron manhole cover and frame No

Lifting key for manhole cover No

User note:

Step irons are only measurable where inspection chambers are

Page 162: Model Bill

measured out in detail i.e. not measurable when in number

The following in ? catchpits, junction boxes and inlet manholes

The following in ? inspection chambers

Excavation not exceeding 2m deep m3

Excavation exceeding ?m and not exceeding ?m deep m3

Unreinforced concrete in bottoms m3

Reinforced concrete in bottoms m3

Unreinforced concrete benching in bottom of ? x ?mm chamber, No dished down to channels and finished smooth with plaster

? x ? x ?mm Thick precast concrete reducer slab including necessary No formwork and reinforcement

? x ? x ?mm Thick precast concrete cover slab with ? x ?mm rebated No opening for cover and frame and finished smooth on exposed surfaces with plaster including necessary formwork and reinforcement

?mm Diameter mild steel reinforcement bars in concrete bottoms t

?mm Diameter high tensile reinforcement bars in concrete bottoms t

One brick wall m2

One and a half brick wall m2

Extra for fair face to brickwork in horizontal stretcher bond pointed m2 with flush joints

Plaster on brick walls m2

? x ?mm x ?kg Cast iron dished grating and frame No

? x ?mm x ?kg Type ? cast iron dished grating and frame No

? x ?mm x ? kg Cast iron single seal manhole cover and frame No

? x ?mm x ?kg Type ? cast iron single seal manhole cover and frame No

? x ?mm x ?kg Cast iron double seal manhole cover and frame No

? x ?mm x ?kg Type ? cast iron double seal manhole cover and frame No

?mm Diameter ?kg type ? cast iron manhole cover and frame No

Page 163: Model Bill

20mm Diameter galvanised steel rod step iron 450mm long built in No across corner of chamber

173 x 240mm Cast iron horseshoe pattern step iron built into No brickwork

Lifting key for manhole cover No

French drains

French drain ? x ? x ?mm long No

Septic tanks

? precast concrete septic tank ?mm diameter and ?mm deep No

Everite fibre-cement septic tank ?mm diameter and ?mm deep No

Sundries

Extra over excavation in earth for pipe trenches, chambers, etc for m3 excavation in soft rock

Extra over excavation in earth for pipe trenches, chambers, etc for m3 excavation in hard rock

Extra over excavation for pipe trenches, chambers, etc for carting m3 away surplus material to a dumping site to be located by the contractor

Extra over backfilling to pipe trenches, chambers, etc for compaction m3 to ?% Mod AASHTO density

Extra over backfilling to drain trenches, chambers, etc for earth m3 backfilling supplied by the contractor

Above item only measured if relevant preamble for full depth of backfill is not used

Unreinforced concrete encasing to horizontal pipe m3

Unreinforced concrete encasing to vertical pipe m3

Unreinforced concrete encasing to ?mm horizontal pipe m

Unreinforced concrete encasing to ?mm vertical pipe m

Unreinforced concrete encasing to ?mm vertical bend No

? x ? x ?mm Precast concrete inspection eye marker slab set in No ground

Page 164: Model Bill

100mm Cast iron "ABC" cleaning eye No

?mm ? cleaning eye No

Cutting into existing ?mm drain pipe for and forming junction with No ?mm pipe

Cutting into side of existing inspection chamber for and connecting No ?mm pipe including inserting ?mm channel junction and making good concrete benching

Testing drainage pipe system Item

RAINWATER DISPOSAL

?mm Galvanised sheet iron

Watertite aluminium

? aluminium

Everite fibre-cement

Marley Vynadeep uPVC

Marley Streamline uPVC

?mm Half round eaves gutters m

?mm Half round eaves gutters with beaded front edge m

?mm Ogee eaves gutters m

? x ?mm Eaves gutters m

? x ?mm Eaves gutters with beaded front edge m

? x ? x ?mm VHV eaves gutters m

Extra over ? eaves gutter for stopped end No

Extra over ? eaves gutter for angle No

Extra over ? eaves gutter for outlet for ?mm pipe No

Extra over ? eaves gutter for outlet for ? x ?mm pipe No

?mm Diameter rainwater pipes m

? x ?mm Rainwater pipes m

Extra over ? rainwater pipe for bend No

Extra over ? rainwater pipe for shoe No

Page 165: Model Bill

Extra over ? rainwater pipe for eaves or plinth offset ?mm projection No

Spreader ?mm long for ?mm diameter pipe with half closed ends and No 20mm holes at 50mm centres

Spreader ?mm long for ? x ?mm pipe with half closed ends and No 20mm holes at 50mm centres

Spreader for ?mm pipe No

Spreader for ? x ?mm pipe No

? x ? x ?mm Deep rainwater head with outlet for ? pipe No

Cast iron pipes

Cast iron pipes with ? joints

Galvanised steel pipes

uPVC pipes

?mm Pipes m

?mm Pipes chased into brick walls m

?mm Pipes suspended exceeding ?m and not exceeding ?m below m suspension level

?mm Pipes on purpose-made supports (supports elsewhere) m

?mm Pipes laid in and including trenches not exceeding 1m deep m

Extra over cast iron pipes for fittings

Extra over cast iron pipes with ? joints for fittings

Extra over galvanised steel pipes for steel fittings

Extra over uPVC pipes for fittings

?mm Elbow No

?mm Bend No

?mm Tee No

Page 166: Model Bill

?mm Junction No

? x ? x ?mm Reducing junction No

Fulbore cast iron outlets

?mm Vertical outlet No

?mm ? Degree side outlet No

?mm Two-way outlet No

SANITARY FITTINGS

Stainless steel

Mewa stainless steel

Citimetal stainless steel

Stainless steel for economy basins, domestic sinks, worktops and No wash troughs shall be type 430 (17/0)

Stainless steel for urinals, basins, quality sinks, wash troughs, No institutional equipment, etc shall be type 304 (18/8)

Stainless steel for laboratory sinks, photographic equipment, etc shall No be type 316 (18/8)

Model ? wash hand basin No

Range of ? model ? wash hand basins No

Range of ? model ? wash hand basins including stainless steel wall No brackets

Range of ? model ? wash hand basins including galvanised steel No stand

Range of ? model ? wash hand basins including stainless steel stand No

Sink and drainer ? x ?mm wide with one bowl No

Sink and drainer ? x ?mm wide with one bowl including ?mm No diameter galvanised steel pipe brackets with ends fanged and built into brickwork

Sink and drainer ? x ?mm wide with one bowl and ?mm high No splashback along back

Sink and drainer ? x ?mm wide with one bowl and ?mm high No splashback along back and one end

Sink and drainer ? x ?mm wide with two bowls No

Page 167: Model Bill

Sink and drainer ? x ?mm wide with two bowls and ?mm high No splashback along back

Sink and drainer ? x ?mm wide with two bowls and ?mm high No splashback along back and one end

Model ? laundry trough No

Range of ? model ? laundry troughs No

Straight back urinal ? x ?mm high with ? litre "Shires Lynx" No automatic flushing cistern, flush and sparge pipes and hinged domical grating

Straight back urinal ? x ?mm high with ? litre "Vaal" automatic No flushing cistern, flush and sparge pipes and hinged domical grating

Straight back L-shaped urinal ?mm girth extreme and ?mm high with No ? litre "?" automatic flushing cistern, flush and sparge pipes and hinged domical grating

? Curved back urinal ? x ?m high with ? litre "Shires Lynx" No automatic flushing cistern, flush and sparge pipes and hinged domical grating

? Combination curved back urinal ? x ?mm high with standard No integral automatic flushing tray, drip cock and hinged domical grating

Kwikot Sinkhot

? x ? x ?mm High sink unit including electric water heater, sink, No valves, pillar cocks, etc

Vaal

Armitage Shanks

Cobra

Taphole stopper No

? x ? x ?mm ? shower tray No

? x ?mm ? lavatory basin No

? x ?mm ? lavatory basin on ? pedestal No

? x ?mm ? cloakroom basin No

? wc pan with double flap ? plastic seat (flushing valve elsewhere) No

Low level wc suite comprising ? pan with double flap ? plastic seat No

Page 168: Model Bill

and ? cistern with flush pipe

? close coupled wc suite comprising pan with double flap ? plastic No seat and cistern

? wall hung wc pan with double flap ? seat and ? chair bracket No (flushing valve elsewhere)

? bidet No

? wall urinal with spreader (flushing valve elsewhere) No

? wall urinal with ? litre automatic flushing cistern with exposed No flush pipe and spreader

?mm ? bath No

WASTE UNIONS ETC

32mm Bath overflow union No

32mm Basin waste union No

32mm ? waste union No

38mm Bath or sink waste union No

TRAPS ETC

uPVC

Marley

?mm Deep seal "P" or "S" trap No

? x ?mm Deep seal "P" or "S" trap No

?mm Reseal "P" or "S" trap No

? x ?mm Reseal "P" or "S" trap No

40mm Bath trap complete with overflow outlet and pipe No

40mm Reseal bath trap with overflow outlet and pipe No

40 x 300mm Sink combination for double bowl with deepseal "P" trap No

40 x ?mm ? combination for double bowl with deepseal "P" trap No

40 x ?mm ? combination for double bowl with reseal "P" trap No

Vulcathene

Page 169: Model Bill

?mm Anti-vac bottle trap No

Cast iron

?mm Trap No

?mm Urinal trap No

Brass

?mm Trap No

?mm "P" trap No

?mm Reseal "P" trap No

?mm Shower trap including stainless steel grating No

40mm Bath trap No

40mm Bath trap with overflow outlet and pipe No

40mm Deep seal bath trap with overflow outlet and pipe No

40mm Reseal bath trap complete with overflow outlet and pipe No

Lead

?mm Trap No

?mm Trap with brass cleaning eye No

32mm "P" trap with brass cleaning eye No

Chromium plated

? x ?mm Bottle trap No

Cobra Watertech

75mm VA3.113 CP hinged urinal domical grating No

32mm 340 CP bottle trap No

?mm ? Bottle trap No

?mm ? Bottle trap with tail pipe No

40mm "P" bath trap complete with "Dura" overflow combination No

TAPS, VALVES, ETC

Brass

Page 170: Model Bill

?mm Stopcock No

?mm Fullway gate valve No

?mm Bibcock with hose union No

?mm Non-return valve No

Cobra Watertech

?mm 058CP extension piece 75mm long No

?mm 059CP extension piece with sliding wall flange No

15mm ?CP angle regulating valve No

?mm 121RB stopcock No

?mm 131RB stopcock No

?mm 126CP stopcock No

?mm 136CP stopcock No

?mm 128CP "Star" underwall pattern stopcock No

?mm 128CP "?" underwall pattern stopcock No

?mm 138CP "?" underwall pattern stopcock No

?mm 1001/125RB fullway gate valve No

?mm 1003/125RB fullway gate valve No

?mm 100RB bibcock No

?mm 106CP "?" bibcock No

?mm 107ECCP bibcock with hose union No

?mm 111CP pillarcock No

?mm 114CP "?" pillarcock No

15mm 900CP single taphole basin mixer No

15mm ?CP "?" single taphole basin mixer with angle flow regulating No valves

?mm ?CP "?" sink mixer No

22mm ?CP "?" bath mixer No

?mm ?CP "?" bath mixer with ? hand shower No

Page 171: Model Bill

?mm 181/020/070CP shower mixer No

?mm ?CP bath spout No

15mm 078CP shower rose No

15mm CP shower rose No

15mm 027CP overhead shower arm No

15mm ? overhead shower arm No

?mm 700RB high pressure float valve including ball No

?mm 1022RB check valve No

?mm 1025RB automatic closing check valve No

?mm 1050RB in-line strainer No

15mm 1065CP fullway ballcock No

15mm ? fullway ballcock No

?mm 1080RB fullway ballcock with lever handle No

PB1.10RB vacuum breaker No

PA1.1LRB "Closy" 100 kPa pressure reducing valve with PB1.10RB No vacuum breaker

PA1.1L+RB "Closy" 200 kPa pressure reducing valve with No PB1.10RB vacuum breaker

PA1.1RB "Kwikflo" 400 kPa pressure reducing valve No

FJ2.100CP "Flushmaster Junior" toilet flush valve No

? "Flushmaster Junior" toilet flush valve No

FJ8.102CP "Flushmaster Junior" urinal flush valve No

? "Flushmaster Junior" urinal flush valve No

FM1.100CP "Flushmaster" toilet flush valve No

? "Flushmaster" toilet flush valve No

SANITARY PLUMBING

Excavation not exceeding 2m deep for pipe trenches m3

Page 172: Model Bill

Backfilling to pipe trenches m3

Backfilling to pipe trenches compacted to ?% Mod AASHTO density m3

User note:

All sizes of ends or branches to reducing fittings shall be given where pipes exceed 60mm diameter

Cast iron pipes

Cast iron pipes with ? joints

Galvanised steel pipes

uPVC pipes

Vulcathene pipes

?mm Pipes laid in trenches (trenches elsewhere) m

?mm Pipes m

?mm Pipes chased into brick walls m

?mm Pipes suspended exceeding ?m and not exceeding ?m below m suspension level

?mm Pipes on purpose-made supports (supports elsewhere) m

?mm Pipes laid in and including trenches not exceeding 1m deep m

?mm Pipes laid in and including trenches not exceeding 1m deep m under surface beds

Extra over cast iron pipes for fittings

Extra over cast iron pipes with ? joints for fittings

Extra over galvanised steel pipes for steel fittings

Page 173: Model Bill

Extra over galvanised steel pipes for brass fittings

Extra over uPVC pipes for fittings

Extra over "Vulcathene" pipes for fittings

?mm End cap No

?mm Bush No

? x ?mm BSP adaptor No

?mm Reducer No

?mm Eccentric reducer No

?mm Taper pipe No

?mm ABC cleaning eye in end of pipe No

?mm Expansion connection No

?mm Bend No

?mm Junction No

?mm Inverted junction No

?mm Reducing junction No

? x ? x ?mm Reducing junction No

? x ? x ?mm Inverted reducing junction No

?mm Double junction No

? x ? x ?mm Reducing double junction No

?mm Offset ?mm projection No

?mm Pan connector No

?mm Bent pan connector No

?mm Access bent pan connector No

?mm Access bent pan connector with anti-syphon horn No

?mm Access pipe No

?mm Access bend No

?mm Access bend with anti-syphon horn No

Page 174: Model Bill

?mm Access junction No

?mm Access reducing junction No

? x ? x ?mm Access reducing junction No

?mm Access double junction No

? x ? x ?mm Access reducing double junction No

?mm Air vent cowl No

?mm "Sovent" de-aerator and deviation line set complete with No air-separation chamber bend, junction and pipework

?mm x ? way "Sovent" aerator junction with ? ?mm inlets No

?mm x ? way "Sovent" aerator junction with ? ?mm and ? ?mm inlets No

?mm "GI Two-way" vent valve No

Sundries

Wire balloon grating in top of pipe not exceeding 100mm diameter No

Testing waste pipe system Item

WATER SUPPLIES

Excavation not exceeding 2m deep for pipe trenches m3

Backfilling to pipe trenches m3

Backfilling to pipe trenches compacted to ?% Mod AASHTO density m3

Everite CID class ? fibre-cement pressure pipes

Class ? uPVC pressure pipes

Polylink polypropylene pipes

?mm Pipes laid in trenches (trenches elsewhere) m

?mm Pipes laid in and including trenches m

Extra over fibre-cement pressure pipes for "Triplex" fittings

?mm Angle coupling No

?mm Bend No

?mm Irrigation branch coupling No

Page 175: Model Bill

Extra over fibre-cement pressure pipes for cast iron fittings

Extra over fibre-cement pressure pipes for steel fittings

?mm End cap No

?mm Reducer No

?mm Flange adaptor drilled to table ? No

?mm Bend No

?mm Irrigation branch coupling No

?mm Tee No

? x ? x ?mm Reducing tee No

?mm Hydrant tee No

?mm Scour valve tee No

?mm Saddle piece including drilling boss No

?mm Cross No

over uPVC pressure pipes for solvent welded pressure fittings

User note:

Only applies to pipes up to 40mm diameter, except bends which apply to all pipes

Extra over "Polylink" polypropylene pipes for fittings

?mm Fittings No

User note:

Previous item applies only to fittings to uPVC pressure pipes not exceeding 30mm diameter

?mm End cap No

?mm Reducer No

?mm Elbow No

?mm Bend No

Page 176: Model Bill

?mm Tee No

? x ? x ?mm Reducing tee No

?mm Union No

?mm Adaptor coupling No

Extra over uPVC pressure pipes for cast iron pressure fittings No

User note:

Only applies to pipes of 50mm diameter and over, except bends which are uPVC

over "Polylink" polypropylene pipes for cast iron pressure fittings

?mm End cap No

?mm Reducer No

?mm Tee No

?mm Reducing tee No

? x ? x ?mm Reducing tee No

?mm Saddle including nuts and bolts and drilling boss and pipe No

?mm Hydrant tee drilled to table ? including connecting bolts, No gaskets, etc

?mm Scour tee drilled to table ? including connecting bolts, gaskets, No etc

?mm Flange adaptor drilled to table ? including connecting bolts, No gaskets, etc

Galvanised steel pipes

Polycop polypropylene pipes with "Fast-fuse" thermoplastic fittings

Polycop polypropylene pipes with brass compression fittings

Class ? copper pipes

?mm Pipes laid in trenches (trenches elsewhere) m

?mm Pipes m

Page 177: Model Bill

?mm Pipes chased into brick walls m

?mm Pipes laid in and including trenches m

Extra over galvanised steel pipes for steel fittings

?mm Fittings No

User note:

Previous item applies only to fittings to pipes not exceeding 30mm diameter

?mm Plug No

?mm Bush No

?mm Elbow No

?mm Bend No

?mm Tee No

?mm Reducing tee No

? x ? x ?mm Reducing tee No

?mm Longscrew connector No

?mm Union No

?mm "Johnson" coupling No

Extra over class ? copper pipes for capillary fittings

?mm Fittings No

User note:

Previous item applies only to fittings to pipes not exceeding 30mm diameter

?mm Cap No

?mm Reducer No

? x ?mm Reducer No

Page 178: Model Bill

?mm Elbow No

?mm Tee No

?mm Reducing tee No

? x ? x ?mm Reducing tee No

?mm Threaded tap connector No

?mm Threaded adaptor No

?mm Threaded union No

?mm Threaded elbow No

?mm Threaded tee No

Extra over "Polycop" polypropylene pipes for "Fast-fuse" thermoplastic fittings

Extra over "Polycop" polypropylene pipes for brass compression fittings

over class ? copper pipes for brass compression fittings

?mm Fittings No

User note:

Previous item applies only to fittings to pipes not exceeding 30mm diameter

?mm End plug No

?mm Adaptor coupling No

?mm Pillar tap adaptor coupling No

?mm Bent adaptor coupling No

?mm Bent adaptor coupling with wall plate No

?mm Elbow No

?mm Tee No

?mm Tee adaptor coupling No

?mm Tee adaptor coupling with wall plate No

?mm Reducing coupling No

Page 179: Model Bill

?mm Reducing adaptor coupling No

?mm Reducing bent adaptor coupling No

?mm Reducing elbow No

?mm Reducing tee No

? x ? x ?mm Reducing tee No

?mm Multi-step reducer No

Copper overflow and service pipes

22mm Overflow pipe 500mm girth twice bent No

?mm Overflow pipe ?mm girth ? bent No

?mm Service pipe ?mm girth No

Sundries

? x ?mm Cast iron stopcock box including brick chamber below not No exceeding ?mm deep internally

? x ?mm Meter or valve box including brick chamber below not No exceeding ?mm deep internally

ELECTRIC WATER HEATERS

Kwikot

?

? Litre horizontal wall mounted electric water heater No

? Litre horizontal ? mounted electric water heater No

? Litre horizontal ? mounted combination electric water heater No

? Litre vertical electric water heater No

? Litre vertical combination electric water heater No

? Litre "Megaflo" horizontal floor/wall mounted electric water heater No

? Litre "Megaflo" vertical electric water heater No

TANKS ETC

Everite fibre-cement water tanks etc

Page 180: Model Bill

? Litre cylindrical tank complete with lid approximately ?m high No above ground level

? Litre cylindrical tank complete with lid and tray approximately ?m No high above ground level

? Litre barrel tank complete with lid approximately ?m high above No ground level

? Litre barrel tank complete with lid and inspection cover No approximately ?m high above ground level

Outlet union for ?mm copper pipe including hole through tank No

Outlet union for ?mm steel pipe including hole through tank No

Outlet union for ?mm ? pipe including hole through tank No

0,6mm Galvanised sheet steel

? x ?mm Drip tray with 100mm high upstand with top edge bent over No all round including 50mm diameter overflow pipe ?mm long approximately ?m above ground level

? Litre circular corrugated tank ?mm high with 0,8mm sheet steel top No and bottom and 200mm diameter removable manhole cover with inside and bottom of tank painted with bituminous paint including ?mm diameter overflow pipe ?mm long approximately ?m above ground level

Outlet union for ?mm ? pipe including hole through tank No

View Engineering hot dip galvanised steel sectional water tanks etc

Dorbyl Prestank hot dip galvanised steel sectional water tanks etc

? hot dip galvanised steel sectional water tanks etc

? x ? x ?mm Tank with external flanges and flat top including bolted No manhole lid approximately ?m above ground level

? x ? x ?mm Tank with external flanges and flat top including raised No valve box and bolted manhole lid approximately ?m above ground level

Outlet union for ?mm ? pipe including hole through tank No

TESTING

Testing water pipe system Item

FIRE APPLIANCES ETC

Page 181: Model Bill

Chubb

Everyway hose reel complete with 30m plastic hose, chromium No plated stopcock, shut-off nozzle and wall bracket

Everyway hose reel complete with 30m rubber hose, chromium No plated stopcock, shut-off nozzle and wall bracket

9 Litre water fire extinguisher No

9 Litre foam fire extinguisher No

? Litre ? fire extinguisher No

2,5kg BCF fire extinguisher No

9kg Dry chemical fire extinguisher No

4,5kg Carbon dioxide fire extinguisher No

6,8kg Carbon dioxide fire extinguisher No

2,5kg Halon fire extinguisher No

5kg Halon fire extinguisher No

?kg ? fire extinguisher No

100mm Diameter 2500 kPa pressure gauge syphon and stopcock No including tapped hole in steel pipe

80 x 65mm Brass hydrant booster connection with cap and chain No

80 x 65mm Brass right angle hydrant valve with cap and chain No

80 x 65mm Brass double booster pump connection with caps and No chains

Fire hydrant pedestals

Unreinforced concrete hydrant pedestal 900mm high cast around No vertical pipe with bottom 300mm below ground, 300 x 300mm square at base and tapering to octagonal shaped top 200 x 200mm overall including necessary excavation, formwork and two coats of paint to exposed surfaces

WATER SUPPLIES TO FIRE APPLIANCES

Excavation not exceeding 2m deep for pipe trenches m3

Backfilling to pipe trenches m3

Backfilling to pipe trenches compacted to ?% Mod AASHTO density m3

Page 182: Model Bill

Everite COD class ? fibre-cement pressure pipes

Everite CID class ? fibre-cement pressure pipes

Class ? uPVC pressure pipes

?mm Pipes laid in trenches (trenches elsewhere) m

?mm Pipes laid in and including trenches m

Extra over fibre-cement pressure pipes for "Triplex" fittings

?mm Angle coupling No

?mm Bend No

?mm Irrigation branch coupling No

Extra over fibre-cement pressure pipes for cast iron fittings

?mm End cap No

?mm Bend No

?mm Tee No

?mm Reducing tee No

? x ? x ?mm Reducing tee No

?mm Hydrant tee No

?mm Scour valve tee No

Extra over uPVC pipes for uPVC solvent welded pressure fittings

User note:

Only applies to pipes up to 40mm diameter, except bends which apply to all pipes

?mm End cap No

?mm Reducer No

?mm Elbow No

?mm Bend No

?mm Tee No

Page 183: Model Bill

?mm Reducing tee No

? x ? x ?mm Reducing tee No

?mm Adaptor coupling No

Extra over uPVC pipes for cast iron pressure fittings

User note:

Only applies to pipes of 50mm diameter and over, except bends which are uPVC

?mm End cap No

?mm Reducer No

?mm Tee No

?mm Reducing tee No

? x ? x ?mm Reducing tee No

?mm Saddle including nuts and bolts and drilling boss and pipe No

?mm Hydrant tee drilled to table ? including connecting bolts, No gaskets, etc

?mm Scour tee drilled to table ? including connecting bolts, gaskets, No etc

?mm Flanged adaptor drilled to table ? including connecting bolts, No gaskets, etc

Galvanised steel pipes

Class ? copper pipes

Excavation not exceeding 2m deep for pipe trenches m3

Backfilling to pipe trenches m3

Backfilling to pipe trenches compacted to ?% Mod AASHTO density m3

?mm Pipes laid in trenches (trenches elsewhere) m

?mm Pipes m

?mm Pipes chased into brick walls m

Page 184: Model Bill

?mm Pipes laid in and including trenches m

Extra over galvanised steel pipes for steel fittings

Extra over class ? copper pipes for brass compression fittings

?mm Fittings No

User note:

Previous item applies only to fittings to pipes not exceeding 30mm diameter

?mm Bush No

?mm Elbow No

?mm Bend No

?mm Tee No

?mm Reducing tee No

? x ? x ?mm Reducing tee No

?mm Longscrew connector No

?mm Union No

?mm Adaptor coupling No

?mm Bent adaptor coupling No

? x ?mm Multi-step reducer No

Sundries

Unreinforced concrete in thrust blocks at bends, tees, etc including m3 necessary extra excavation, formwork, etc

? x ?mm Cast iron stopcock box including brick chamber below not No exceeding ?mm deep internally

? x ?mm Cast iron meter box including brick chamber below not No exceeding ?mm deep internally

? x ?mm Valve chamber not exceeding ?mm deep internally (cover No and frame elsewhere)

? x ?mm x ?kg Cast iron cover and frame No

Page 185: Model Bill

Testing fire water pipe system Item

PIPE PROTECTION

Densyl Tape

Wrapping around ?mm pipe including couplings m

Extra for wrapping around fittings No

User note:

Previous item applies only to fittings to pipes not exceeding 30mm diameter

Extra for wrapping around ?mm bend No

Extra for wrapping around ?mm tee No

Extra for wrapping around ?mm valve No

LAGGING

Paper lagging

Two layers of stout brown paper tightly wrapped around ?mm pipe m and couplings and tied with wire prior to building in

Extra for wrapping around fittings No

User note:

Previous item applies only to fittings to pipes not exceeding 30mm diameter

Extra for wrapping around ?mm bend No

Extra for wrapping around ?mm tee No

Extra for wrapping around ?mm valve No

Thermaflex pipe insulation

Insulation to ?mm pipe and couplings m

Extra for wrapping around fittings No

User note:

Previous item applies only to fittings to pipes not exceeding 30mm

Page 186: Model Bill

diameter

Extra for wrapping around ?mm bend No

Extra for wrapping around ?mm tee No

Extra for wrapping around ?mm valve No

Fibreglass Snap on plain sections

Fibreglass Snapon canvas covered sections

Fibreglass Snapon polyisobutylene covered waterproof sections

Insulation 15mm thick to 15mm pipes and couplings m

Insulation 15mm thick to 20mm pipes and couplings m

Insulation 15mm thick to 25mm pipes m

Insulation ?mm thick to ?mm pipes m

Extra for working around fittings No

User note:

Previous item applies only to fittings to pipes not exceeding 30mm diameter

Extra for working around ?mm bend No

Extra for working around ?mm tee No

Extra over for working around ?mm valve No

FLUE PIPES ETC

Everite fibre-cement flue pipes and fittings

?mm Pipes m

? x ?mm Pipes m

Extra over ? pipe for bend No

Extra over ? pipe for access bend No

Cowl for ? pipe No

Page 187: Model Bill

H-type cowl for ? pipe No

SLEEVES

0,6mm Galvanised sheet iron sleeves with welted seams for pipes not exceeding 100mm diameter

0,6mm Galvanised sheet iron sleeves with welted seams for pipes exceeding 100mm and not exceeding 200mm diameter

Plastic sleeves for pipes not exceeding 100mm diameter

Plastic sleeves for pipes exceeding 100mm and not exceeding 200mm diameter

Sleeve not exceeding 250mm long No

Sleeve exceeding 250mm and not exceeding 500mm long No

HOLES ETC

Core drilling of hole for pipe not exceeding 50mm diameter

?mm Reinforced concrete slab, beam, wall, etc No

Core drilling of hole for pipe exceeding 50mm and not exceeding 100mm diameter

?mm Reinforced concrete slab, beam, wall, etc No

BILL ?

GLAZING

GLAZING TO STEEL WITH PUTTY

GLAZING TO STEEL WITH SCREWED ON BEADS (BEADS ELSEWHERE)

GLAZING TO ALUMINIUM WITH SCREWED ON BEADS (BEADS ELSEWHERE)

GLAZING TO ALUMINIUM WITH CLIP ON BEADS (BEADS ELSEWHERE)

GLAZING TO WOOD WITH PUTTY

GLAZING TO WOOD WITH PINNED ON BEADS (BEADS ELSEWHERE)

? mm Clear float glass

? mm Patterned glass

Page 188: Model Bill

? mm Rough cast glass

? mm Georgian wired rough cast glass

? mm Georgian wired polished glass

? mm Clear toughened safety glass

? mm "Fadeban" normal strength clear laminated safety glass

? mm ? normal strength clear laminated safety glass

?mm "Fadeban" high penetration resistance clear laminated safety glass

?mm ? high penetration resistant clear laminated safety glass

?mm "Solarshield S20" high penetration resistant heat reflecting laminated safety glass

? mm "Solarshield G/20 Gold" high impact heat reflecting laminated safety glass

? mm ? high impact heat reflecting laminated safety glass

Panes not exceeding 0,1 m2 m2

Panes exceeding 0,1m2 and not exceeding 0,5m2 m2

Panes exceeding 0,5m2 and not exceeding 2m2 m2

Panes exceeding 2m2 and not exceeding 4m2 m2

Panes exceeding ? m2 and not exceeding ? m2 m2

Panes not exceeding 0,1 m2 in shapes other than rectangular m2

Panes exceeding 0,1 m2 and not exceeding 0,5 m2 in shapes other m2 than rectangular

Panes exceeding 0,5 m2 and not exceeding 2 m2 in shapes other than m2 rectangular

Panes exceeding 2 m2 and not exceeding 4 m2 in shapes other than m2 rectangular

Panes exceeding ? m2 and not exceeding ? m2 in shapes other than m2 rectangular

Sundries

Polished edges to ? mm monolithic glass m

Polished edges to ? mm laminated glass m

Page 189: Model Bill

Butt joints to ?mm toughened glass including polished edges and m silicone sealant

Butt joints to ?mm laminated glass including polished edges and m silicone sealant

Type ? glazing gaskets m

Extra for moulded corner to type ? glazing gaskets No

Sandblasting ? x ? high glass pane No

Sandblasted motif to ? x ? high glass pane No

Set of ? sandblasted motifs to ? x ? high glass pane No

GLASS LOUVRE BLADES

? mm ? glass louvre blades

Louvre blades ? mm wide with polished edges m

TOPS, SHELVES, DOORS, MIRRORS, ETC

? mm Float glass with polished edges all round

? mm Clear toughened safety glass with polished edges all round

? mm Float quality ? normal strength laminated safety glass with polished edges all round

Top ? x ? mm wide laid loose No

Shelf ? x ? mm wide No

Sliding door ? x ?mm high with ? x ? mm sunk fingergrip No

? mm Silvered float glass copper backed mirrors with polished edges fixed with double sided adhesive tape

? mm Silvered float glass copper backed mirrors with 10 mm bevelled and polished edges fixed with double sided adhesive tape

Mirror ? x ? mm high No

? mm Silvered float glass copper backed mirrors with polished edges holed for and fixed with chromium plated dome capped mirror screws with rubber buffers to plugs in brickwork or concrete

? mm Silvered float glass copper backed mirrors with 10 mm bevelled and polished edges holed for and fixed with chromium plated dome capped mirror screws with rubber buffers to plugs

Page 190: Model Bill

in brickwork or concrete

Mirror ? x ? mm high with ? screws No

PATENT GLAZING

? mill finish aluminium patent glazing system with head channel, sill section, intermediate vertical glazing bars fixed at top and bottom with fixing saddles bolted on and glazed with ? mm float quality ? high impact resistant laminated safety glass

Patent glazing ? x ? m high with glazing bars at ? mm centres and No fixing head channel and sill section to brickwork or concrete

Patent glazing ? x ? m high with glazing bars at ? mm centres and No fixing head channel and sill section to steel structure including drilling steel

BILL ?

PAINTWORK

PREPARATORY WORK TO EXISTING WORK

Previously painted plastered surfaces

Surfaces shall be thoroughly washed down and allowed to dry completely before any paint is applied. Blistered or peeling paint shall be completely removed and cracks shall be opened, filled with a suitable filler and finished smooth

Previously painted metal surfaces

Surfaces shall be thoroughly rubbed and cleaned down. Blistered or peeling paint shall be completely removed down to bare metal

Previously painted wood surfaces

Surfaces shall be thoroughly cleaned down. Blistered or peeling paint shall be completely removed and cracks and crevices shall be primed, filled with suitable filler and finished smooth

PAINTWORK ETC TO NEW WORK

PAINTWORK ETC TO PREVIOUSLY PAINTED WORK

ON SLATE

Page 191: Model Bill

ON BRICKS OR QUARRY TILES

Two coats wax polish

Two coats linseed oil

Two coats brick dressing

On floors m2

On sills, thresholds, etc m2

On flush pointed faced walls m2

On recessed pointed faced walls m2

ON FLOATED PLASTER

ON TEXTURED PLASTER

ON SMOOTH CONCRETE

ON ROUGH CONCRETE

ON BAGGED BRICKWORK OR CONCRETE

ON FAIR FACED BRICKWORK

ON PLASTER BOARD

ON FIBRE-CEMENT

One coat bonding liquid and two coats interior quality PVA emulsion paint

One coat primer and two coats interior quality PVA emulsion paint

One coat sealer and two coats interior quality PVA emulsion paint

One coat interior quality PVA emulsion paint on work in good condition

Two coats interior quality PVA emulsion paint on work in bad condition

One coat bonding liquid and two coats exterior quality PVA emulsion paint

One coat primer and two coats exterior quality PVA emulsion paint

Page 192: Model Bill

One filler coat and two coats exterior quality PVA emulsion paint

One coat primer and two coats polyacrylic emulsion paint

One coat sealer and two coats polyacrylic emulsion paint

One acrylic filler coat and two coats polyacrylic emulsion paint

Two coats ? waterproof cement wash

One coat bonding liquid and two coats ? marble texture coating

Two coats floor enamel paint

One coat primer and two coats ? polyurethane velvet enamel paint

One coat alkali resistant primer, one undercoat and ? coat/coats ? eggshell enamel paint

One coat alkali resistant primer, one undercoat and ? coat/coats ? alkyd enamel paint

One coat primer and two coats ? chemical resistant paint

Two "?" acrylic base coats and one coat "?" multi coloured acrylic paint

Two "?" acrylic base coats, one coat "?" multi coloured acrylic paint and one coat glaze paint

One coat bonding liquid two coats interior quality PVC emulsion

paint in colours which have a value of 7 or less on the Munsell

system in accordance with SABS 1091

One coat primer and two coats interior quality PVC emulsion paint in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091

One coat sealer and two coats interior quality PVC emulsion pint in colours which have a value of 7 or less on the Munsell system in

accordance with SABS 1091

One coat interior quality PVC emulsion paint in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091 on work in good condition

Page 193: Model Bill

Two coats interior quality PVC emulsion paints in colours which

have a value of 7 or less on the Munsell system in accordance with

SABS 1091 on work in bad condition

One coat bonding liquid and two coats exterior quality PVC

emulsion paint in colours which have a value of 7 or less on the

Munsell system in accordance with SABS 1091

One coat primer and two coats exterior quality PVC emulsion paint in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091

One coat primer and two coats polyacrylic emulsion paint in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091

One coat sealer and two coats polycrylic emulsion paint in colours

which have a value of 7 or less on the Munsell system in accordance with SABS 1091

One acrylic filler coat and two coats polyacrylic emulsion paint in

colours which have a value of 7 or less on the Munsell system in

accordance with SABS 1091

One coat primer and two coats ? polyutherane velvet enamel paint in colours which have a value of 7 or less on the Munsell system in

accordance with SABS 1091

One coat alkali resistant primer, one undercoat and ? coat/coats ?

eggshell enamel paint in colours which have a value of 7 or less on

the Munsell system in accordance with SABS 1091

Page 194: Model Bill

One coat alkali resistant primer, one undercoat and ? coat/coats ?

alkyd enamel paint in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091

On power floated floors m2

On internal walls m2

On internal walls in patterned multi-colours m2

On internal mouldings and bands in colours differing from m2 surrounding work

On external walls m2

On external walls in patterned multi-colours m2

On external mouldings and bands in colours differing from m2 surrounding work

On ceilings and beams m2

On ribbed ceilings m2

On coffered ceilings m2

On partitions m2

On ceilings and cornices m2

On fascias and barge boards m2

On flue pipes m2

On internal mouldings and bands not exceeding 300 mm wide or girth m in colours differing from surrounding work

On external mouldings and bands not exceeding 300mm wide or girth m in colours differing form surrounding work

On fascias and barge boards not exceeding 300 mm girth m

On flue pipes not exceeding 300 mm girth m

Lines ? wide m

User Note:

The following eight items are to be given only in instances where

Page 195: Model Bill

users make use of the "extra over" option as set out in amendment 38/1996.

Extra over paintwork finished in two coats interior quality PVA m2 emulsion paint for finishing coats in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091.

Extra over one coat interior quality PVA emulsion paint on work in m2 good condition for paint in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091

Extra over two coats interior quality PVA emulsion paint on work in m2 bad condition for paint in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091

Extra over paintwork finished in two coats exterior quality PVA m2 emulsion paint for finishing coats in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091

Extra over paintwork finished in two coats polyacrylic emulsion paint m2 for finishing coats in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091

Extra over paintwork finished in two coats ? polyutherane velvet m2 enamel paint for finishing coats in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091

Extra over paintwork finished in ? coat/coats ? eggshell enamel paint m2 for finishing coat/coats in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091

Extra over paintwork finished in ? coat/coats alkyd enamel paint for m2 finishing coat/coats in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091

ON METAL

Page 196: Model Bill

One coat zinc chromate primer and two coats aluminium paint on steel

Spot priming defects in pre primed surfaces with zinc chromate primer and applying one undercoat and ? coat/coats ? alkyd enamel paint on steel

One coat ? alkyd enamel paint on previously painted steel in good condition

Spot priming bare metal surfaces with zinc chromate primer and applying one undercoat and ? coat/coats ? alkyd enamel paint on previously painted steel in bad condition

Spot priming defects in pre primed surfaces with polyamide cured epoxy zinc chromate primer and applying one polyamide cured epoxy undercoat and ? coat/coats ? polyamide cured finishing epoxy paint on steel

One coat self-etching primer, one undercoat and ? coat/coats ? alkyd enamel paint on galvanised steel

One coat calcium plumbate primer, one undercoat and ? coat/coats ? alkyd enamel paint on galvanised steel

One coat self-etching primer, one undercoat and ? coat/coats ? alkyd enamel paint on copper

Three coats "Interlac" lacquer (CAB7) on copper

One coat aluminium primer, one undercoat and ? coat/coats ? enamel paint on cast iron

Spot priming defects in pre primed surfaces with zinc chromate

primer and applying one undercoat and ? coat/coats alkyd enamel

paint in colours which have a value of 7 or less on the Munsell

system in accordance with SABS 1091

One coat ? alkyd enamel paint in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091 on

previously painted steel in good condition

Spot priming bare metal surfaces with zinc chromate primer an

applying one undercoat and ? coat/coats ? alkyd enamel paint in

Page 197: Model Bill

colours which have a value of 7 or less on the Munsell system in

accordance with SABS 1091 on previously painted steel in bad

condition

Spot priming defects in pre primed surfaces with polyamide cured

epoxy zinc chromate primer and applying one polyamide cured epoxy undercoat and ? coat/coats ? polyamide cure finishing epoxy in colours which have a value of 7 or less on the Munsell system in

accordance with SABS 1091 on steel

One coat self-etching primer, one undercoat and ? coat/coats alkyd enamel paint in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091 on galvanised steel

One coat calcium plumbate primer, one undercoat an ? coat/coats ? alkyd enamel paint in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091 on galvanised steel

One coat self-etching primer, one undercoat and ? coat/coats ?

alkyd enamel paint in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091 on copper

One coat aluminium primer, on undercoat and ? coat/coats ? alkyd

enamel paint in colours which have a value of 7 or less on the

Munsell system in accordance with SABS 1091 on cast iron

On doors m2

On door frames m2

On record room and strongroom doors and frames m2

On roller shutter boxes m2

On windows m2

On windows with burglar bars m2

On columns and beams m2

Page 198: Model Bill

On members of lattice columns and beams m2

On members of roof trusses m2

On gates, grilles, burglar screens, balustrades, etc (both sides m2 measured over the full flat area)

On corrugated iron roof sheeting (measured on flat) m2

On ? profile troughed/ribbed roof sheeting (measured on flat) m2

On rails, bars, pipes, etc m2

On eaves gutters m2

On rails, bars, pipes, etc not exceeding 300 mm girth m

On eaves gutters not exceeding 300 mm girth m

User Note:

The following seven items are to be given only in instances where users make use of the "extra over" option as set out in amendment 38/1996

Extra over paintwork on steel finished in ? coat/coats ? alkyd enamel m2 paint for finishing coat/coats in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091

Extra over one coat ? alkyd enamel paint on previously painted steel m2 in good condition for paint in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091

Extra over paintwork on previously painted steel in bad condition m2 finished in ? coat/coats ? alkyd enamel paint for finishing coat/coats in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091

Extra over paintwork on steel finished in ? coat/coats ? polyamide m2 cured finishing epoxy paint for finishing coat/coats in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091

Page 199: Model Bill

Extra over paintwork on galvanised steel finished in ? coat/coats ? m2 alkyd enamel paint for finishing coat/coats in colours which have a value of 7 or less on the Munsell system in accordance with SABS

1091

Extra over paintwork on copper finished in ? coat/coats ? alkyd m2 enamel paint for finishing coat/coats in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091

Extra over paintwork on cast iron finished in ? coat/coats ? alkyd m2 enamel paint for finishing coat/coats in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091

ON WOOD

Two coats wood primer

On backs of frames, linings, etc not exceeding 300mm wide m2

One coat wood primer, one undercoat and ? coat/coats ? alkyd enamel paint

One coat wood primer and ? coat/coats ? polyurethane velvet enamel paint

One coat ? alkyd enamel paint on previously painted surfaces in good condition

Spot priming bare wood surfaces with wood primer and applying one undercoat and ? coat/coats ? alkyd enamel paint on previously painted surfaces in bad condition

Three coats ? clear wood preservative

Three coats ? clear varnish

Three coats ? matt varnish

Grain filling, two coats sanding sealer and ? coat/coats ? clear lacquer

Grain filling, two coats sanding sealer and two coats beeswax thinned with mineral turpentine

One coat wood primer, one undercoat and ? coat/coats ? alkyd

Page 200: Model Bill

enamel paint in colours which have a value o 7 or less on the

Munsell system in accordance with SABS 1091

One coat wood primer and ? coat/coats ? polyutherane velvet enamel paint in colours which have a value o 7 or less on the Munsell system in accordance with SABS 1091

One coat ? alkyd enamel paint in colours which have a value o 7 or

less on the Munsell system in accordance with SABS 1091 on

previously painted surfaces in good condition

Spot priming bare wood surfaces with wood primer in colours which have a value o 7 or less on the Munsell system in accordance with SABS 1091 on previously painted surfaces in bad condition

On boarded panelling m2

On boarded ceilings m2

On doors m2

On windows, sash doors and fanlights m2

On louvered windows and doors m2

On door frames etc m2

On fittings m2

On roof timbers at eaves and verges m2

On open slatted shelves, seats, etc of ? x ? mm slats at ? mm centres m2 (both sides measured over the full flat area)

On open slatted panelling of ? x ? mm slats at ? mm centres with m2 fabric covering at back (measured over the full flat area)

On skirtings, rails, etc not exceeding 300 mm girth m

User Note:

The following four items are to be given only in instances where users make use of the "extra over" option as set out in amendment 38/1996

Page 201: Model Bill

Extra over paintwork finished in ? coat/coats alkyd enamel for m2 finishing coat/coats in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091

Extra over paintwork finished in ? coat/coats polyutherane velvet m2 enamel paint for finishing coat/coats in colours which have a value of 7 or less on the Munsell system in accordance with SABS 1091

Extra over one coat ? alkyd enamel paint on previously painted m2 surfaces in good condition for paint in colours which have a value o 7 or less on the Munsell system in accordance with SABS 1091

Extra over paintwork on previously painted surfaces in bad condition m2 for finished in ? coat/coats alkyd enamel paint for finishing coat/coats in colours which have a value o 7 or less on the Munsell system in accordance with SABS 1091

SIGNWRITING

Suitable paint on plaster, metal, wood or glass

Numeral or letter ?mm high No

Sans serif numeral or letter ? mm high No

Punctuation mark to preceding item No

Identification band ? mm wide on pipe not exceeding 300 mm girth No

Directional arrow not exceeding 150 mm long on pipe No

? Road marking paint on concrete

? Road marking paint on tarmacadam

Line ? mm wide m

Numeral or letter ? mm high No

Traffic arrow ? x ? mm wide extreme No

Earthworks Page -14-

Concrete, Formwork and Reinforcement Page -36-

Page 202: Model Bill

Precast Concrete Page -42-

Masonry Page -67-

Waterproofing Page -73-

Roof Coverings Page -87-

Carpentry and Joinery Page -19-

Ceilings, partitions and Access Flooring Page -121-

Floor Coverings, Plastic Linings, etc. Page -125-

Ironmongery Page -137-

Structural Steelwork Page -143-

Metalwork Page -164-

Plastering Page -169-

Tiling Page -174-

Plumbing and Drainage (Provisional) Page -214-

Glazing Page -218-

Paintwork Page -23-

RATE# 0