General Electric Hitachi Laser-Based
Uranium Enrichment Facility SafetyEvaluation Report
1
Tim Johnson, NRC Licensing ProjectManager
Nick Baker, Project Manager
May 10, 2012
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
2/34
Objectives
Provide Brief Summary of Safety Evaluation Report
2
Discuss future project milestones
Answer public questions
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
3/34
Project Background
GEH is proposing to enrich uranium using alaser-based process at its site in Wilmington,NC
Enriched uranium is needed for fuel for
3
Environmental report submitted in January2009
License application submitted in June 2009
NRC safety and environmental reviewscompleted in February 2012
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
4/34
4
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
5/34
5
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
6/34
Licensing Process
NRC is an independent agency responsible for
ensuring protection of public and worker health and
safety in the use of radioactive materials
NRC is not a promoter of this project
6
Enrichment facility construction cannot begin until a
license for construction and operation is issued
A hearing is required for uranium enrichment
facilities
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
7/34
NRC Review Process Utilized safety, environmental, and security
review staff as well as contractors
Followed a standard review plan, NUREG-
7
of a License Application for a Fuel CycleFacililty
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
8/34
NRC Review Process
Followed Environmental Review
Guidance for Licensing ActionsAssociated with NMSS Programs,
-
8
Issued requests for additional
information and conducted conferencecalls and meetings
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
9/34
NRC Review Process
GLE revised license applicationaccordingly
9
NRC documented the review in theSafety Evaluation Report and Final
Environmental Impact Statement
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
10/34
NRC Safety Evaluation Report (SER)
NRC conducted safety reviews in the followingareas:
General Information Organization and Administration
Integrated Safety Analysis
Radiation Protection
10
Nuclear Criticality Safety Chemical Safety
Fire Safety
Environmental Protection
Decommissioning Management Measures
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
11/34
NRC Safety Evaluation Report (SER)
Materials Control and Accounting
Physical Protection Transportation Security
Human Factors Engineering
11
NRCs Safety Evaluation Report documentsthe results of the safety review of the above
areas
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
12/34
General Information
General facility function and site information
Financial qualifications
Foreign ownership and control
12
Liability insurance Classified information protection
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
13/34
Organization and Administration
Organization and administration capable of
performing safety functions
13
Management and staff will have proper
training and qualifications
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
14/34
Integrated Safety Analysis (ISA)
Performed by GLE
ISA Summary reviewed by NRC staffduring safety review
14
radiological and chemical risks from
potential accidents
Identifies measures to prevent ormitigate potential accidents
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
15/34
ISA Process
Key elements:
Performance requirements Evaluation of potential accident
sequences and consequences
15
Identification of Items Relied on for Safety(IROFS)
Management measures
Plant change process
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
16/34
IROFS Must be in place for higher-risk accident
sequences
Prevent or mitigate the consequences of such
accidents
16
, , ,
components, and personnel actions
Management measures in place to ensure
availability and reliability
GLE adequately provided information about
IROFS
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
17/34
ISA Summary Review
NRC staff reviewed the GLE ISA
Summary and supporting documentation
Staff visited GLE site to review detailed
17
ISA Summary
Sufficient information was provided about
the site, facility processes, hazards, andtypes of accident sequences
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
18/34
ISA Summary Review Accident sequences addressing radiological,
chemical, criticality, and fires, as well as effectsof natural phenomena, were adequately
addressed
18
GLE identified suitable IROFS and management
measures to ensure the IROFS would be
available and reliable to perform their functionswhen needed
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
19/34
Radiation Protection
GLE has an adequate program for
protecting workers and members of thepublic from exposure to radiation
19
, ,
and monitoring
Program ensures that worker and public
doses are a low as is reasonablyachievable
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
20/34
Criticality Safety
Facility design includes active, passive, and
administrative features to prevent criticality GLE has an adequate program for protecting
a ainst criticalit
20
Program includes qualified staff to develop,implement, and maintain the program and
procedures
Program meets regulatory requirements
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
21/34
Chemical Safety GLE adequately described and assessed
chemical accident sequences andconsequences
GLE performed hazard analyses that identified
21
and evaluated chemical processes and potentialaccidents
GLE established safety controls for potential
accidents that meet regulatory requirements
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
22/34
Fire Safety GLE has a program in place that provides
reasonable assurance the facility isprotected against fire hazards
22
and administrative controls to minimize
risk of fire and explosions
Program includes IROFS and defense-in-depth protection
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
23/34
Emergency Management
GLE provided an adequate Emergency Plan
(EP) for the facility
GLE commits to maintaining and executing the
23
hazards if they occur
EP requirements are implemented through
approved written procedures and in coordination
with local response organizations
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
24/34
Environmental Protection
GLE has an adequate program for
protecting the environment Program includes environment and
24
Program includes controls to maintain
effluent releases as low as is reasonably
achievable
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
25/34
Decommissioning
GLE proposed an adequate decommissioning
funding plan (DFP) DFP provides a reasonable cost estimate for
decommissioning
25
DFP addresses costs for decontaminating thefacility and for waste management, including the
dispositioning of depleted uranium tails
GLE is proposing to use a surety bond for itsfinancial assurance mechanism
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
26/34
Management Measures
GLE provided adequate information about
measures that will be applied to theproject, including
26
Maintenance program
Training program
Process for development, approval, andimplementation of procedures
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
27/34
Security
GLE provided adequate programs for
Physical security of the facility
Protection of classified information
27
material
Transportation of enriched materials
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
28/34
Human Factors Engineering
GLE provided information on its technical
approach for considering human factors inthe plant design and operation
28
The approach is integrated into the ISA
process to ensure that IROFS will be
available and reliable when needed
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
29/34
Electrical and Instrumentation
and Controls
GLE provided information on the electrical
system and on instrumentation andcontrols
29
to operate
GLE is not using digital instrumentation
and controls for its safety systems
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
30/34
Final Environmental Impact
Statement
Jennifer Davis
30
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
31/34
Future Project Milestones
Mandatory hearings July 2012
Licensing board decision August 2012 If board makes positive
31
,
Construction begins 2014
Operations begin 2015
Full production 2018
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
32/34
SER and FEIS Availability
SER is available at:
http://pbadupws.nrc.gov/docs/ML1206/ML12060A007.pdf
FEIS, Volumes 1 and 2, are available at:
http://pbadupws.nrc.gov/docs/ML1204/ML12047A040.pdf
32
and
http://pbadupws.nrc.gov/docs/ML1204/ML12047A042.pdf
NRC has GLE project web site at:
http://www.nrc.gov/materials/fuel-cycle-fac/laser.html
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
33/34
NRC Licensing Process
NRC Contacts:
Tim Johnson, Licensing Project Manager;
301-492-3121; [email protected]
33
Jennifer Davis, Environmental Project
Manager; 301-415-3835;
7/31/2019 ML12129A474 - General Electric Hitachi Laser-BasedUranium Enrichment Facility Safety Evaluation Report
34/34
Summary
Provided Brief Summary of Safety Evaluation
Report