MKP-ANSI (ASME-Compliant)Stainless Steel Magnetic Drive Chemical Process Pump
The sealless MKP-ANSI magnetic drive pump is ideal to meet the stringent requirements of chemical processing and a multitude of other industries. This highly advanced and extremely energy efficient pump is built to handle a huge variety of fluids reliably and absolutely safely.
With its special design using an inverted drive configuration, the MKP-ANSI requires no plain bearing carrier. The pumped fluid provides optimum lubrication and cooling of the single, centrally located impeller bearing assembly, also allowing solids-laden and low-boiling liquids to be pumped. Depending on the pumped medium, it can handle fluids containing solids in concentrations up to 30% with a particle size up to 1∕25�.
The pump impeller rotates stably about a stationary axis on the gyroscopic principle, maintaining a perfect hydraulic balance. This minimises bearing loads, increasing the reliabil-ity of pump operation.
Added to its compact design with virtually no dead areas, the MKP-ANSI is constructed with just a few, robust components. An intelligent modular system facilitates assembly and keeps the costs of spare parts, maintenance and servicing to a min-imum.
The MKP-ANSI is available in a variety of designs and config-urations. Its connection dimensions and performance data conform to ASME B73.3, making the MKP-ANSI easy to retro-fit into any installation to replace old pumps.
Configurations and mounting arrangements
– Close-coupled – Horizontal – Baseplate – Bracket
Casing materials
– Stainless steel – Uranus® B6 – Nickel-base alloys, e.g. Hastelloy® B or C – Pure nickel – Titanium
Pump protection
– Containment shell thermocouple – Double-walled containment shell with leakage monitoring – Pt100 temperature probe – Motor load sensor
Processes and fluids
Some typical services include: – Chlor-alkali electrolysis – Refrigeration and heating cycles – Hydrogen peroxide – Molten sulphur – Potassium hydroxide solution – Sulphuric acid
2014
0411
_DO
K_M
KP-A
NSI
_Fac
tshe
et_e
n 04
051-
03
© CP Pumpen AG, Switzerland, www.cp-pumps.com
Technical data
Capacities (min./max.) 1 to 450 gpm
Heads (min./max.) 10 to 310 ft
Temperatures (min./max.) –148°F to +482°F
Kinematic viscosities 0.5 to 350 mm2/s
Solids concentration up to 30% depending on fluid
Directives and standards
ANSI/ASME B73.3
Your CP distributor
3000 rpm/50 Hz 1500 rpm/50 Hz
1800 rpm/60 Hz3600 rpm/60 Hz
MKP-ANSI 15 A 200
50 Hz Rev. 3 25.02.11 Tf
0
50
100
150
200
250
300
350
400
450
500
550
1 10 100 1000 10000
0
20
40
60
80
100
120
140
1 10 100 1000 10000
3000 min-1
1500 min-1
Q [gpm]
H [f
t]H
[ft]
Q [gpm]
20-1
5-20
0 20
-15-
160
1½ x
1 -
6 1½
x 1
- 8
50-3
2-25
0
65-4
0-25
0
80-5
0-25
0
50-3
2-16
0 50
-32-
200
3 x
1½ -
6 3
x 1½
- 8
3 x
2 - 6
3
x 2
- 8
125-
80-2
00
20-1
5-20
0 20
-15-
160
1½ x
1 -
6 1½
x 1
- 8
50-3
2-25
0
65-4
0-25
0
80-5
0-25
0
50-3
216
0-
50-3
2-20
0
3 x
1½ -
6 3
x 1½
- 8
3 x
2 - 6
3
x 2
- 8
125-
80-2
00
150-
125-
315
200-
150-
315
100-
65-2
0010
0-65
-160
100-
65-1
6010
0-65
-200
125-
80-2
50
125-
80-2
50
125-
100-
200
125-
100-
200
125-
80-3
15
125-
80-3
15
80-5
0-31
5
80-5
0-31
5
MKP-ANSI 15 A 200
50 Hz Rev. 3 25.02.11 Tf
0
50
100
150
200
250
300
350
400
450
500
550
1 10 100 1000 10000
0
20
40
60
80
100
120
140
1 10 100 1000 10000
3000 min-1
1500 min-1
Q [gpm]
H [f
t]H
[ft]
Q [gpm]
20-1
5-20
0 20
-15-
160
1½ x
1 -
6 1½
x 1
- 8
50-3
2-25
0
65-4
0-25
0
80-5
0-25
0
50-3
2-16
0 50
-32-
200
3 x
1½ -
6 3
x 1½
- 8
3 x
2 - 6
3
x 2
- 8
125-
80-2
00
20-1
5-20
0 20
-15-
160
1½ x
1 -
6 1½
x 1
- 8
50-3
2-25
0
65-4
0-25
0
80-5
0-25
0
50-3
216
0-
50-3
2-20
0
3 x
1½ -
6 3
x 1½
- 8
3 x
2 - 6
3
x 2
- 8
125-
80-2
00
150-
125-
315
200-
150-
315
100-
65-2
0010
0-65
-160
100-
65-1
6010
0-65
-200
125-
80-2
50
125-
80-2
50
125-
100-
200
125-
100-
200
125-
80-3
15
125-
80-3
15
80-5
0-31
5
80-5
0-31
5
MKP-ANSI 15 A 30060 Hz Rev. 2 25.02.11 Tf
050
100150200250300350400450500550600650700750800
1 10 100 1000 10000
0
20
40
60
80
100
120
140
160
180
200
1 10 100 1000 10000
3600 min
1800 min
20-1
5-20
0 20
-15-
160
1½ x
1-6
1½
x 1
-8
50-3
2-25
0
65-4
0-25
0
80-5
0-25
0
50-3
2-16
0 50
-32-
200
3 x
½ -
6 3
x 1½
- 8
3 x
2 - 6
3
x 2
- 8
125-
80-2
00
20-1
5-20
0 20
-15-
160
1½ x
1 -
6 1½
x 1
- 8
50-3
2-25
0
65-4
0-25
0
80-5
0-25
0
50-3
2-16
0 50
-32-
200
3 x
1½ -
6 3
x 1½
- 8
3 x
2 - 6
3
x 2
- 8
125-
80-2
00
150-
125-
315
100-
65-2
0010
0-65
-160
200-
150-
315
100-
65-2
0010
0-65
-160
125-
80-2
50
125-
100-
200
80-5
0-31
5
125-
80-3
15
80-5
0-31
5
125-
80-3
15
125-
80-2
50
125-
100-
200
Q [gpm]
H [f
t]H
[ft]
Q [gpm]
MKP-ANSI 15 A 30060 Hz Rev. 2 25.02.11 Tf
050
100150200250300350400450500550600650700750800
1 10 100 1000 10000
0
20
40
60
80
100
120
140
160
180
200
1 10 100 1000 10000
3600 min
1800 min
20-1
5-20
0 20
-15-
160
1½ x
1-6
1½
x 1
-8
50-3
2-25
0
65-4
0-25
0
80-5
0-25
0
50-3
2-16
0 50
-32-
200
3 x
½ -
6 3
x 1½
- 8
3 x
2 - 6
3
x 2
- 8
125-
80-2
00
20-1
5-20
0 20
-15-
160
1½ x
1 -
6 1½
x 1
- 8
50-3
2-25
0
65-4
0-25
0
80-5
0-25
0
50-3
2-16
0 50
-32-
200
3 x
1½ -
6 3
x 1½
- 8
3 x
2 - 6
3
x 2
- 8
125-
80-2
00
150-
125-
315
100-
65-2
0010
0-65
-160
200-
150-
315
100-
65-2
0010
0-65
-160
125-
80-2
50
125-
100-
200
80-5
0-31
5
125-
80-3
15
80-5
0-31
5
125-
80-3
15
125-
80-2
50
125-
100-
200
Q [gpm]
H [f
t]H
[ft]
Q [gpm]
Follow us on: