Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
Compact Indoor Units
The thin, ceiling-concealed indoor units of the PE-P series are the perfect answer for the air-conditioning requirements of buildings with minimum ceiling installation space and wide-ranging external static pressure.
Ceiling concealed (PE-P Series)
250mm
428mm
Height reduced
PE-P18/24/30/36/42/48JAK
PE-4EAK
400mm
PE-5EAK2
Air InletUnits with bottom inlets make more noise than those with rear inlets. It is recommended that the rear inlet be selected when installing a unit in a room that has to be quiet, such as a bedroom.
(1) Rear inlet (2) Bottom inlet
Air inlet
Air outlet Air outletAir inlet
Wide Selection of External Static Pressure
Flexible duct design
Features at a glanceComfort OthersInstallation & Maintenance
• System control• Auto restart • Outdoor unit max. operating temp. of 46ºC
• Quiet operation • Computerized dehumidifier • Chargeless system
• Smooth installation• Self-diagnostic function
External static pressure settingSeries
PE-P.JAK
18 24 30 36 42 48
30/50Pa 30/50/70Pa
PE-P18JAK PE-P24JAK PE-P30JAK PE-P36JAK PE-P42JAK PE-P48JAKkW 5.1 6.3 8.3 10.4 12.4 13.5BTU/h 17,400 21,500 28,300 35,500 42,300 46,000kW 1.74 2.22 2.91 3.52 5.64 5.44W/W 2.93 2.84 2.85 2.95 2.2 2.48
CMM 17.5-27 17.5-27 24-34 24-34 28-42 28-42CFM 618-953 618-953 847-1,200 847-1,200 988-1,482 988-1482Pa 30-50 30-50 30-50-70 30-50-70 30-50-70 30-50-70
dB (A) 30-38 30-38 34-45 34-45 36-45 36-45mm O.D. 32 O.D. 32 O.D. 32 O.D. 32 O.D. 32 O.D. 32mm 1,100 1,100 1,400 1,400 1,400 1,400mm 732 732 732 732 732 732mm 250 250 250 250 250 250kg 29 29 38 38 38 38
PU-P18VAKD PU-P24VAKD PU-P30VAKD PU-P36YAKD PU-P42YAKD PU-P48YAKD
CMM (CFM) 31(1095) 53(1871) 50(1765) 95(3350) 100(3530) 90(3,180)dB (A) 51 54 55 54 56 56mm 840 870 970 970
m 50
mmLiquid: 6.35Gas: 12.7
1ph 220-240V 50Hz 3ph 380-415V 50Hz
Pipe size (outer diameter)Liquid: 9.52Gas: 15.88
Weight Max. height differenceMax. piping length 24 40
Dimensions
Guaranteed Opearating Range Upper limit (DB) 45Lower limit (DB) 21
Outdoorunit
Model namePower supplyExternal finish Munsell 3.0Y 7.8/1.1Refrigerant R410AAirflow Noise level
Indoorunit
Power supply 1ph 220-240V 50HzExternal finish Galvanized sheets
Airflow (low-high)
External static pressure*Opearation control Remote controlNoise level (low-high)Unit drain pipe
Dimensions
Weight
EER
ModelsCooling capacityCooling capacityTotal input
Specifications
WDH
WDH
mm 330 295 345 345mm 880 1258 1258 1258kg 36 56 72 85 108 114
m 10 15 30 30
• Rating conditions Cooling - Indoor: 270F (800F) DB,190F (660F) WB, Outdoor: 350F (950F) DB
• Refrigerant piping length (one-way): 7.5m(25ft)
• Specifications subject to change without notice.
New Publicaiton effective from February, 2017
NON INVERTER
Three-stage external static pressure conversions are available. Capable of being set to a maximum of 70Pa, these units are appro-priate for a wide range of building types.
The unit height is unified to 250mm for all models. Compared to the pre vious models, the height has been reduced, allowing easy installation in tight spaces such as ceiling cavities or drop-ceilings.
Sales Office#
Raipur
Ranchi
Kolkata
Nagpur
Jaipur
Gurugram
Agra
Amritsar
Dehradun
Bhopal
DelhiGhaziabad
ChandigarhLudhiana
AhmedabadIndore
Surat
Pune Hyderabad
Vijaywada
Hubli
Bengaluru
Bhubaneswar
Trichy
Visakhapatnam
Kochi
Coimbatore
Lucknow
Goa
Kanpur
Rajkot
VaranasiPatna
Aurangabad
Chennai
Mumbai
“For E-waste Collection & Disposal process: Customer can get complete details of company process on collection, disposal of e-waste product (i.e. ‘Mitsubishi Electric’ make Air Conditioner / Printers) and incentive / exchange scheme for returning of e-waste on Company website (www.mitsubishielectric.in) and / or Toll free number 1800 102 2626.
Customer Care Toll Free No.: 1800 102 2626
BRANCH/SALES OFFICES: Ahmedabad - 079-67777888; Bengaluru - 080-40201600; Coimbatore - 0422-4385606;Chandigarh - 0172-4601645; Chennai - 044-49232222; Delhi - 011-66057900; Ghaziabad - 0120-4093681;Hyderabad - 040-43438888; Indore - 0731-4098991; Jaipur - 0141-4011109; Kolkata - 09038050952/3; Kochi - 0484-4862093;Lucknow - 0522-4002607; Ludhiana - 0161-4061654; Mumbai - 022-66116200; Nagpur - 0712-2284020; Pune - 020-27102000;Surat - 0261-4003111; Vijaywada - 0866-6516999SATELLITE OFFICES: Agra - 09536900140; Amritsar - 09780021037; Aurangabad - 09923339333; Bhopal - 09926347222;Bhubaneshwar - 09073949597; Dehradun - 08650158786; Goa - 09167113443; Hubli - 0844-8398010; Kanpur - 09205987322; Patna - 09073949596; Raipur - 08448397997; Rajkot - 09586605009; Ranchi - 0973949598; Trichy - 09205599022; Varanasi - 09559302666; Vizag - 09951655556
MITSUBISHI ELECTRIC INDIA PVT. LTD.HEAD OFFICE: 2nd Floor, Tower A & B, DLF Cyber Green, DLF Cyber City, DLF Phase 3,Gurugram - 122002 (Haryana)
TECHNICAL CENTRES:Bengaluru: 080-40201600; Chennai: 044-49232222; Delhi: 011-66057900; Mumbai: 022-66116200Tel. No.: (Main): 0124-6739300 Fax: 0124-4630399
Website: in.MitsubishiElectric.com Email: [email protected]
800285550
840330880
Liquid: 9.52Gas: 15.88
Liquid: 6.35Gas: 15.88
PL-P18/24/30/36/42/48BAK
PL-P18BAK PL-P24BAK PL-P30BAK PL-P36BAK PL-P42BAK PL-P48BAK
kW 5.1 6.6 8.3 10.4 12.4 13.2
17,400 22,500 28,300 35,500 42,300 45,000
1.67 2.17 2.83 3.37 5.54 5.25
3.05 3.04 2.93 3.59 2.24 2.51
BTU/h
kW
W/W
Models
Total Input*2
EER
Cooling Capacity*1
Indoorunit
Outdoorunit
Power Supply
Dimensions
Weight
Max. height difference
Max. piping length
Pipe size (outer diameter)
Guaranteed Opearating Range
BEE Star Rating
External Finish
Weight (panel)
Model name
Power supply
External finish
Refrigerant
Airflow
Noise level
Airflow (low-mid2-mid1-high)
Noise Level (low-mid2-mid1-high)
Unit Drain Pipe (Outer Diameter)
Dimensions (Panel)
External Static Pressure
Operation Control
1ph 220-240V 50Hz 1ph 220-240V 50Hz
Munsell 6.4Y 8.9/0. Munsell 6.4Y 8.9/0.4
Upper limit(DBt)
Lower limit(DBt)
CMM
CFMpa
dB (A)
mm
mm
mm
mm
kg
CMM (CFM)
dB (A)
mmW
D
H
W
D
H
mm
mm
m
m
mm
kg
850-920-1025-1130
14-16-18-20
495-565-635-705 850-920-1025-1130
24-26-29-3220-24-27-30
705-850-955-1060
19-22-25-28
670-780-885-990
0 (directblow)0 (directblow)
Wireless Remote controlWireless Remote control
28-30-33-35 32-36-39-42 33-37-40-43 38-40-42-45
O.D.32
840 (950)
840 (950)
298 (35)
27 (6)
840 (950)
840 (950)
840 (950)
840 (950)
298 (35)
27 (6)
298 (35)
25 (6)
258 (35)
23 (6)
PU-P48YAKDPU-P18VAKD PU-P24VAKD PU-P30VAKD PU-P36YAKD PU-P42YAKD
Munsell 3.0Y 7.8/1.1
3ph 380-415V 50Hz1ph 220-240V 50Hz
Munsell 3.0Y 7.8/1.1
3ph 380-415V 50Hz
Munsell 3.0Y 7.8/1.1
Capillary TubeR410A R410A
53(1871) 50(1765) 95(3350) 100(3530) 90(3180)31(1095)
5651
800
285
550
330
880
295
1258
345
1258
345
1258
840 870 970
54 55 54 56
970
11410885725636
10 15 30 30 30
504030
4546 45
2021 21
Liquid: 9.52, Gas: 15.88Liquid: 9.52, Gas: 15.88Liquid: 9.52, Gas: 15.88Liquid: 9.52, Gas: 15.88Liquid: 6.35, Gas: 12.7 Liquid: 6.35, Gas: 15.88
*1 Rating conditions Colling-Indoor: 270C (800F) DB, 190C (660F) WB, Outdoor: 350C(950F) DB Refrigerant piping length (one-way): 7.5m (25ft)*2 Total input based on the indicated voltage (indoor/outdoor): 1ph 230v 50Hz / 3ph 400v 50Hz
Specifications
PL-P18/P24BAK
PL-P30/P36/P42/48BAK
PL-P30/P36/P42/48BAK
Automatic Grille LoweringFunction (Optional)
Easy to use/Simple maintenanceAn automatic grille lowering function capable of stopping at eight different heights is avail-able to simplify filter maintenance.
(comes with the automatic elevation panel)
1.2m
1.6m
2.0m
2.4m
2.8m
3.2m
3.6m
4.0m
Automaticelevation to
4.0m
Elevating (up-down) controller
Optional
*PL-P30/36/42/48BAK