2
1 Item Name: 50m 3 TREATED WATER TANK Company Project Number: 2 Item Tag Number: T-04320 Purchase Order Number: 3 No Items: 1 Supplier Project Number: 4 GENERAL 5 Information to be completed by: Purchaser Vender Vender if not completed by Purchaser 6 Applicable to: Proposal Purchase As Built 7 DESIGN CRITERIA 8 Service: Treated Water Tank Material Code: ASME Section II 9 Design Code: ASME Section VIII - Division 1 Shell: A516-60 10 Vessel Size: ID. 2800 mm S/S 8100 mm Head: A516-60 11 Thickness: Shell: mm Head: mm Pipes: A106Gr.B 12 Vessel Type: Vertical Horizontal Flange: A105 13 Heads: 2:1 Ellipse Other Type: Blots: A193 14 Medium: Hydrogen Lethal Cyclic Nuts: A194-2H 15 Severe Wet H 2 S Gaskets: Spirally Wound Non-asbestos Gaskets 16 Location: Indoor Outdoor Supports: A36 17 Under Shelter Internals: A36 18 PROCESS DATA 19 Total Flow: 67 m³/h Manufacturing Code: ASME Section VIII-Division 1 20 Operating Pressure: 0.08 Mpag Welding Code: ASME Section IX 21 Operating Temperature: 40 o C NDE Code: ASME Section V 22 Vapor Density: kg/m³ Ultrasonic: As Per Code 23 Liquid Density: 900 kg/m³ Magnetic Paricle: As Per Code 24 Code: ASME Stamp Yes No X-Ray Inspection Length: As Per Code 25 Board Registration: Yes No X-Ray NDE Grade: As Per Code 26 Internal Design Pressure: 0.1 Mpag Hydraulic Test: Yes No 27 Top, Mpa at o C Painting and Packing: Yes No 28 Bottom, Mpa at o C As Per Specification: MIS-L-SP-03537 29 Design Temp: 60 o C Corrosion Prevention: Yes No 30 Normal Liquid Level: mm Lifting Lug: Yes No 31 Max Wind Speed: 29.8 m/s 32 Seismic Zone: hold 33 Corrosion Allowance: Mist Eliminator: Yes No 34 Shell: 3 mm Heads: 3 mm Nozzles: 3 mm Type: 35 Insulation: Yes No Vortex Breakers: Yes No 36 Type: Thickness: Coil: Yes No 37 Others: 38 39 Rev. Date Description MATERIALS MANUFACTURE AND TEST REQUIREMENTS INTERNALS Lu Huanxuan Jul. 26,05 Issued for Approval Fan Xixuan Tao Lifeng C Aug. 8,05 Issued for Approval Fan Xixuan A Jun. 18,05 Issued for Comments Fan Xixuan MIS DEVELOPMENT PROJECT 50 m 3 TREATED WATER TANK DATA SHEET DOCUMENT NO.: MIS-M-DS-04052 CLIENT: CNPCI/NESCO Consortium UNIT: PU & DP PAGE 1 OF 2 Tao Lifeng Lu Huanxuan Zhai Feng REV. C Lu Huanxuan By Zhai Feng Tao Lifeng Zhai Feng Approved Checked Reviewed B

MIS-M-DS-04052 50m3 Treated Water Tank Data Sheet(T-04320)-C

Embed Size (px)

Citation preview

Page 1: MIS-M-DS-04052 50m3 Treated Water Tank Data Sheet(T-04320)-C

1 Item Name: 50m3 TREATED WATER TANK Company Project Number:

2 Item Tag Number: T-04320 Purchase Order Number:

3 No Items: 1 Supplier Project Number:

4 GENERAL

5 Information to be completed by: Purchaser Vender Vender if not completed by Purchaser

6 Applicable to: Proposal Purchase As Built

7 DESIGN CRITERIA

8 Service: Treated Water Tank Material Code: ASME Section II

9 Design Code: ASME Section VIII - Division 1 Shell: A516-60

10 Vessel Size: ID. 2800 mm S/S 8100 mm Head: A516-60

11 Thickness: Shell: mm Head: mm Pipes: A106Gr.B

12 Vessel Type: Vertical Horizontal Flange: A105

13 Heads: 2:1 Ellipse Other Type: Blots: A193

14 Medium: Hydrogen Lethal Cyclic Nuts: A194-2H

15 Severe Wet H2S Gaskets: Spirally Wound Non-asbestos Gaskets

16 Location: Indoor Outdoor Supports: A36

17 Under Shelter Internals: A36

18 PROCESS DATA

19 Total Flow: 67 m³/h Manufacturing Code: ASME Section VIII-Division 1

20 Operating Pressure: 0.08 Mpag Welding Code: ASME Section IX

21 Operating Temperature: 40 oC NDE Code: ASME Section V

22 Vapor Density: kg/m³ Ultrasonic: As Per Code

23 Liquid Density: 900 kg/m³ Magnetic Paricle: As Per Code

24 Code: ASME Stamp Yes No X-Ray Inspection Length: As Per Code

25 Board Registration: Yes No X-Ray NDE Grade: As Per Code

26 Internal Design Pressure: 0.1 Mpag Hydraulic Test: Yes No

27 Top, Mpa at oC Painting and Packing: Yes No

28 Bottom, Mpa at oC As Per Specification: MIS-L-SP-03537

29 Design Temp: � 60 oC Corrosion Prevention: Yes No

30 Normal Liquid Level: mm Lifting Lug: Yes No

31 Max Wind Speed: 29.8 m/s

32 Seismic Zone: hold

33 Corrosion Allowance: Mist Eliminator: Yes No

34 Shell: 3 mm Heads: 3 mm Nozzles: 3 mm Type:35 Insulation: Yes No Vortex Breakers: Yes No

36 Type: Thickness: Coil: Yes No

37 Others:

38

39

Rev. Date Description

MATERIALS

MANUFACTURE AND TEST REQUIREMENTS

INTERNALS

Lu Huanxuan

Jul. 26,05 Issued for Approval Fan Xixuan Tao Lifeng

C Aug. 8,05 Issued for Approval Fan Xixuan

A Jun. 18,05 Issued for Comments Fan Xixuan

MIS DEVELOPMENT PROJECT50 m3 TREATED WATER TANK

DATA SHEET

DOCUMENT NO.: MIS-M-DS-04052CLIENT: CNPCI/NESCO Consortium UNIT: PU & DP PAGE 1 OF 2

Tao Lifeng Lu Huanxuan Zhai Feng

REV. C

Lu Huanxuan

By

Zhai Feng

Tao Lifeng Zhai Feng

ApprovedChecked Reviewed

B

Page 2: MIS-M-DS-04052 50m3 Treated Water Tank Data Sheet(T-04320)-C

1

2 Type of Support: Empty Weight: By Vendor kg

3 Skirt Legs Saddle Lugs Operating Weight: By Vendor kg

4 Insulation Supports: Yes No Weight Filled With Water: By Vendor kg

5 Fire Proofing Supports: Yes No Dimension:

6 Skid Mounted: Yes No L x W x H: mm

7 Manway Davit/Hinge: Yes No

8 Ladder: Yes No

9 Platform: Yes No

10

11 Service

12 Breather Valve

13 Inlet(from Produced Water Sedimentation Tank )

14 Inlet

15 Outlet

16 Drain

17 Level Gauge

18 Manway with Davit

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39 NOTE:

40 1. All nozzle orientations to be defined later.

41 2. Reference PID: MIS-P-DW-01702. Applicable spec: MIS-M-SP-04005.

42

43

ANSI 150

ANSI 300

ANSI 150

RF

N2 1 6" RF

RF

RFN4 1 6"

LG1-2 2 2" RF

MW 1 24" RF

N5 1 4"

N3 1 6"

PAGE 2 OF 2 DOCUMENT NO.: MIS-M-DS-04052 REV. C

MIS DEVELOPMENT PROJECT50 m3 TREATED WATER TANK

DATA SHEET

CLIENT: CNPCI/NESCO Consortium UNIT: PU & DP

WEIGHT AND DIMENSION

ANSI 150

NOZZLES

ANSI 150

Mark

N1

Rating

ANSI 150

RF

ATTACHMENT

ANSI 150

TypeSizeQty

1 4"