8
MIS 1.5 Hardware Overview

MIS 1.5 Hardware Overview. MIS Chassis Rear access to power supplies, server modules, KVM ports, and all cabling Includes: Case with bifurcated top covers

Embed Size (px)

Citation preview

Page 1: MIS 1.5 Hardware Overview. MIS Chassis Rear access to power supplies, server modules, KVM ports, and all cabling Includes: Case with bifurcated top covers

MIS 1.5 Hardware Overview

Page 2: MIS 1.5 Hardware Overview. MIS Chassis Rear access to power supplies, server modules, KVM ports, and all cabling Includes: Case with bifurcated top covers

MIS ChassisRear access to power supplies, server modules, KVM ports, and all cabling

Includes: Case with bifurcated top covers for front and rear accessFront bezel with control panel buttons and indicator LEDsJBOD rear features 4 HD miniSAS, one NIC, and one serial port

Page 3: MIS 1.5 Hardware Overview. MIS Chassis Rear access to power supplies, server modules, KVM ports, and all cabling Includes: Case with bifurcated top covers

Chassis Interior

StorBrick Baseboard

Boot Drive Module

Front Grille and S9D Interface Port

Bridge MidplaneSAS Midplane

SAS Midplane

Bridge Midplane

Fan Baseboard

Fan Module

Power Supply Bridge

Power Supply ModuleServer Module (single server)

StorBrick Drive Bays

s

Chassis Intrusion Detector

Chassis Exterior

Fan Mounting Bracket

Midspan Brace

Page 4: MIS 1.5 Hardware Overview. MIS Chassis Rear access to power supplies, server modules, KVM ports, and all cabling Includes: Case with bifurcated top covers

StorBrick Layout

Dual Server Only

JBOD Only

Page 5: MIS 1.5 Hardware Overview. MIS Chassis Rear access to power supplies, server modules, KVM ports, and all cabling Includes: Case with bifurcated top covers

SAS Interior CablingHBA to SAS Interposer

SAS Midplane to StorBricks

Dual Server

Single Server

Page 6: MIS 1.5 Hardware Overview. MIS Chassis Rear access to power supplies, server modules, KVM ports, and all cabling Includes: Case with bifurcated top covers

Server Module Components

Module Case

Battery Backup Units

Battery Backup Unit Mounting Plate

Air DuctFlexible Shielding

External HBAs

Internal SAS HBAs

External HBAs

Riser 2

Riser 1

Riser 3 Bridge Board

SAS Interposers

Mem

ory D

IMM

s

Mem

ory D

IMM

s

Heat Sinks

Motherboard

Remote Management Console Component

(RMM4Lite)

Single Servers have taller risers allowing for 2 additional HBAs (total 6).Dual Server Module HBAs are half-height (2.12” by 3.375”), with a maximum of 4 HBAs per server module (2 internal & 2 internal or external).

CPU 2

CPU 1

Single Server Module Shown

Page 7: MIS 1.5 Hardware Overview. MIS Chassis Rear access to power supplies, server modules, KVM ports, and all cabling Includes: Case with bifurcated top covers

Customer Replaceable Units (CRUs)

MIS 1.0 CRUs• Fans• Power Supplies• Drives• External Cables• Front Bezel• Rails & external

air ducts

MIS 1.5 CRUs• All 1.0 CRUs• Battery Backup Units*• HBAs & PCIe cards*• Risers*• DIMMs*• JBOD I/O Modules*

* Version -002August 2013

Page 8: MIS 1.5 Hardware Overview. MIS Chassis Rear access to power supplies, server modules, KVM ports, and all cabling Includes: Case with bifurcated top covers

System InterfacesFront Control Panel and LEDs display status and give power control (chassis ID, on/off/reboot). NMI Reset Button not supported (it does nothing).

BMC Web-based interface on server platforms allows for hardware monitoring, email alerts, and remote management. Email alerts require configuration & connection to a mail (SMTP) server. Java Runtime Environment 6 (or later) required for remote desktop.

The Web-based Fan Base Service Page lets customers set fans in a “Safe to Service” mode for replacing fan modules (otherwise emergency shut-down starts after 10 seconds).

MegaRAID Storage Manager monitors capacity drives and RAID processes (mirrors, rebuilds, etc.). The command-line interface CLI Zoning tool (not shown) also has options to view & change drive power status.