Panasonic Professional DisplaysDisplays
The Panasonic family of professional displays can be controlled with Mira Connect™, Aveo Systems’ smart control appliance. Mira Connect communicates and controls the Panasonic displays over an Ethernet network or RS-232, supporting power on/off and source selection of the display.
To get started, create a room in Mira Portal (https://mira.aveosystems.com), and pair a Mira Connect controller to the room or select UI Preview to preview and use simulated equipment.
Add a Panasonic display to the room by clicking ADD and select Panasonic Display from the equipment list.
For the Connection Type, select Ethernet or RS-232 over Ethernet depending on how Mira Connect will communicate with the display. Enter the display’s IP address, and click ‘Add Equipment’. Mira Connect will connect to the Panasonic display and show the status of the connection.
Mira Portal will show the equipment status as a green circle if the IP address is valid and Mira Connect can connect and control the display, otherwise the warning symbol, ! , will appear indicating the IP address is not correct, the RS-232 baud rate is not set correctly on the Global Cache IP2SL interface (for RS-232 over Ethernet), or the device at that IP address is not a Panasonic display.
Select the desired video inputs to used on the display by selecting Edit from the device’s menu, and select the Video Inputs tab. To enable an input, select the input, choose an icon, and enter text labels for the desired input. This will create a display menu as shown in the figure below. While not all inputs are available on all display models, select the inputs that will be used on your display. An optional display name may be entered which is useful if you have multiple displays in a room.
Click ‘Update Equipment’ when done.
See the Mira Connect Administrators Guide for more information about using Mira Portal to configure Mira Connect or see the training videos for examples.
Important information about the integration is summarized below.
1Step Equipment ADD
No equipment is con�gured.
Add Equipment
ADD EQUIPMENT
CONNECTION VIDEO INPUTS
Equipment Type* Select model number*
Connection Type*
Simulate equipment
192.168.80.165
Panasonic Display Universal
RS-232 over Ethernet
Ethernet
CANCEL
192.168.80.165 (Ethernet)Firmware: 003.5200EF1
Panasonic Display
Equipment ADD
2Step
ADD EQUIPMENTCANCEL
Video ConferencingROOM COMPUTER
Corporate InformationDIGITAL SIGNAGE
News ChannelTV TUNER
Select source:
Display Name (Optional)
This menu will appear on Mira Connect. If you have more than one display, enter a name for each. Drag items to change order. The first item is the default selected input.
Panasonic Display
Add Equipment
Equipment Type * Model *
Icon Label
Description (Optional)
HDMI 1 ROOM COMPUTER
Video Conferencing
Description (Optional)
Corporate Information
Icon Label
DIGITAL SIGNAGE
Icon Label
Description (Optional)
Simulate equipmentUniversal
HDMI 2
DISPLAY PORT
DVI-D
Menu Preview
CONNECTION VIDEO INPUTS
TV TUNER
News Channel
Mira Connect Integration
R
S Y S T E M S
Aveo Systems, Inc. • 1791 West Oak Parkway • Suite 8 • Marietta, GA 30062 • Phone: +1.678.653.7090 Fax: +1.844.fax.aveo • Email: [email protected] • www.aveosystems.com
R
S Y S T E M S
3Step
Mira Connect Integration with Panasonic Professional Displays
Control Interface OptionsThere are two network control options for controlling Panasonic displays. Regardless of which control option is used, set a static IP address, or use a ‘reserved’ lease on a DHCP server to ensure the IP address does not change over time.
1. Network connection using TCP, port 1024 (Ethernet).
The network driver is compatible with Protocol 2 in ‘non-protected mode’ as described in the display’s user manual. Non-protected mode requires that there be no web control password set. Protocol 2 can be enabled from the display’s setup menu as described in the display’s user manual.
To remove the web control password, browse into the display using the IP address of the display (default IP is 192.168.0.8) and use the default credentials of admin1 and panasonic for user name and password, respectively. Select Change password, select the Administrator account, and click Next. Enter the existing user name (admin1) and password (panasonic), and enter the new user name as admin1 but don’t enter a new password. Press OK when done.
Status Change passwordSelect Account
AdministratorUser
Next
AccountDisplaycontrol
Display Control Window
Detailedset up
Changepassword
Current
New
Change password
Account Administrator
OK
User name
Password
User name
Password
Password (Retype)
2. Network connection using TCP, port 4999 when using the Global Cache IP2SL for RS-232 control (RS-232 over Ethernet)
If using the RS-232 over Ethernet option, see the Global Cache integration guide for set up information. Ensure the RS-232 baud rate on the Global Cache IP2SL matches the baud rate configured for the display. Default RS-232 settings for Panasonic displays are 9,600 baud, 8 data bits, no parity, 1 stop bit, no flow control.
RS-232 control requires a straight-through RS-232 9-pin Female to Female cable between the Global Cache IP2SL and the display that you provide as shown in the following figure.
Equipment to beControlled
Global Cache IP2SL
Pin 1Pin 5
Pin 9 Pin 6
Pin Signal12 RX3 TX45 Ground6789
DB9 FemalePin 1Pin 5
Pin 9 Pin 6
Pin 5Pin 1
Pin 6 Pin 9
DB9 FemaleDB9 Female
Pin Signal1 2 RX3 TX45 Ground6789
DB9 Male
Straight-Through RS-232 Control Cable DB9F - DB9F
RS-232 Connectoris DB9 Male
RS-232 connectoris DB9 Male
R
S Y S T E M S
For more information please contact our Sales Department at [email protected].
About Aveo SystemsAveo Systems is a leading provider of intuitive and easy-to-use solutions for audio, video, and collaboration, improving how systems are used and managed by customers world-wide.
DS-11033-001 Version 2019_04_29
Specifications subject to change without notice. Aveo Systems and the Aveo logo are registered trademarks. All other trademarks are the property of their respective owners.
Mira Connect Integration with Panasonic Professional Displays
Volume ControlThere is no support for volume control of the display. Use a DSP audio conference device or video conferencing system for volume control.
Supported ModelsMira Connect supports the family of Panasonic displays with a universal driver. Since not all inputs are available on all displays, select the desired inputs and add labels as shown on the Display Menu section.
Software VersionsTested with a Panasonic EF1 with firmware v003.5200EF1