1
FLEXIBLE HOSE NOT ALLOWED TO LIE ON GROUND INSTRUCTIONS SIGN RECOMMENDED BY THE MN DEPT OF HEALTH Instructions Connect your hose to holding tank, place other end securely in drain opening while holding cover with foot. Open RV tonk drain valve. Wash away any spillage on concrete into drain. MINIMUM 2' ELEVATION - ----i--t-- -- CONCRETE PAD PITCHED TO DRAIN-~ DANGER Not to be used for drinking or domestic purposes. ,-- -+-+- WATER CONTROL II II VALVE SELF-CLOSING, TIGHT FITTING, FOOT OPERATED HATCH SET FLUSH WITH PAD 3/ 4-INCH POTABLE WATER SUPPLY --...- 1-t- -- 4-INCH SANITARY SEWER PIPED TO APPROVED SEWAGE DISPOSAL SYSTEM NOTE 1: M.R. CHAPTER 4714, SECTION 724.0 ASSE 1001 ATMOSPHERIC VACUUM BREAKER . NO VALVE DOWNSTREAM IS PERMITTED. INSTRUCTIONS SIGN RECOMMENDED BY ===:::::===@ I i: 1 THE MN DEPT OF HEALTH 1GN: 2' x 2' MINIMUM STOP AND WASTE VALVES ARE NOT PERMITTED TO BE INSTALLED UNDERGROUND (SEE SECTION 603 . 5.18) NOTE 2: ---------MINIMUM 10' SEPARATION OF ---- BURIED SEWER AND WATER RISER, UNLESS SEWER MATERIAL IS APPROVED FOR USE WITHIN BUILDINGS (SEE SECTION 609.2). 5' MINIMUM SEPARATION RECOMMENDED. CURB OR BUMPER TO PROTECT RISERS CONCRETE PAD: -MINIMUM 3' X 3' DIMENSIONS -MINIMUM 3-1 /2" THICKNESS -TROWELED SMOOTH FINIISH A DIRECT CONNECTION BETWEEN THE POTABLE NO YARD HYDRANT OR OTHER WATER SUPPLY PIPING IS WATER SYSTEM AND THE RV HOLDING TANK IS ALLOWED WITHIN 1O' HORIZONTALLY OF A HOLDING TANK NOT ALLOWED (SEE SECTION 603.4.4) OR OTHER SOURCE OF CONTAMINATION (SEE SECTION 609.6.1) RV Sanitary Disposal Station Construction DEPARTMENT OF LABOR AND INDUSTRY Telephone: (651) 284-5063 dli.mn.gov/business/plumbing-contractors/2015-minnesota-plumbing-code 12/20

MINNESOTA RULES, CHAPTER 4714. SECTION 724.0 MN DEPT OF HEALTH … · minnesota rules, chapter 4714. section 724.0 . asse 1001 atmospheric vacuum breaker. no valve downstream is permitted

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MINNESOTA RULES, CHAPTER 4714. SECTION 724.0 MN DEPT OF HEALTH … · minnesota rules, chapter 4714. section 724.0 . asse 1001 atmospheric vacuum breaker. no valve downstream is permitted

FLEXIBLE HOSE NOT ALLOWED TO LIE ON GROUND

INSTRUCTIONS SIGN RECOMMENDED BY THE MN DEPT OF HEALTH

Instructions Connect your hose to holding tank, place other end securely in drain opening while holding cover with foot. Open RV tonk drain valve. Wash away any spillage on concrete into drain.

MINIMUM 2' ELEVATION - ----i--t----

CONCRETE PAD PITCHED TO DRAIN-~

DANGER Not to be used for drinking or domestic purposes.

,---+-+- WATER CONTROL

II II

VALVE

SELF-CLOSING, TIGHT FITTING, FOOT OPERATED HATCH SET FLUSH WITH PAD

3/4-INCH POTABLE WATER SUPPLY

--...-1-t--- 4-INCH SANITARY SEWER PIPED TO APPROVED SEWAGE DISPOSAL SYSTEM

NOTE 1:

M.R. CHAPTER 4714, SECTION 724.0

ASSE 1001 ATMOSPHERIC VACUUM BREAKER. NO VALVE DOWNSTREAM IS PERMITTED.

INSTRUCTIONS SIGN RECOMMENDED BY

===:::::===@ Ii: 1

THE MN DEPT OF HEALTH

1GN: 2' x 2' MINIMUM

STOP AND WASTE VALVES ARE NOT PERMITTED TO BE INSTALLED UNDERGROUND (SEE SECTION 603.5.18)

NOTE 2:

---------MINIMUM 10' SEPARATION OF ---- BURIED SEWER AND WATER

RISER, UNLESS SEWER MATERIAL IS APPROVED FOR USE WITHIN BUILDINGS (SEE SECTION 609.2). 5' MINIMUM SEPARATION RECOMMENDED.

CURB OR BUMPER TO PROTECT RISERS

CONCRETE PAD: -MINIMUM 3' X 3' DIMENSIONS -MINIMUM 3-1 /2" THICKNESS -TROWELED SMOOTH FINIISH

A DIRECT CONNECTION BETWEEN THE POTABLE NO YARD HYDRANT OR OTHER WATER SUPPLY PIPING IS WATER SYSTEM AND THE RV HOLDING TANK IS ALLOWED WITHIN 1O' HORIZONTALLY OF A HOLDING TANK NOT ALLOWED (SEE SECTION 603.4.4) OR OTHER SOURCE OF CONTAMINATION (SEE SECTION 609.6.1)

RV Sanitary Disposal Station ConstructionDEPARTMENT OF LABOR AND INDUSTRY

Telephone: (651) 284-5063 dli.mn.gov/business/plumbing-contractors/2015-minnesota-plumbing-code

12/20