Mini 24 Presents the new

Mini 24 Presents the new. Wall-hung boiler Self diagnostic system Electronic thermometer Furnace type: open Output power: 22,66 kW Min. 6,7 kW Stars of

Embed Size (px)

Citation preview

Mini 24

Presents the new

Wall-hung boiler

Self diagnostic system

Electronic thermometer

Furnace type: open

Output power: 22,66 kW Min. 6,7 kW

Stars of efficiency: *

Expansion vessel: 6 lt.

Flow rate raised t 30°: 11,20 lt/min

Width:410mm

Height: 730mm

Depth: 320mm

RBC 24 EMini 2424 kW

Bithermic exchanger

Open chamber

Wall-hung boiler

Self diagnostic system

Electronic thermometer

Furnace type: sealed

Output power: 23,45 kW Min. 6,7 kW

Stars of efficiency: ***

Expansion vessel: 6 lt.

Flow rate raised t 30°: 11,42 lt/min

Width:410mm

Height: 730mm

Depth: 320mm

RBS 24 EMini 2424 kW

Bithermic exchanger

Sealed chamber

Wall-hung boilerBithermic exchanger

Open chamberSealed chamber

RBC 24RBS 24

Component listMini RBC 24 – RBS 24

1. Bithermic heat exchanger2. Atmosferic burner3. Ignition electrode4. Flame sensing electrode5. Safety heating thermostat6. Electronic gas valve7. Expansion vessel8. Circulating pump 9. Automatic air vent10. 3 bar central heating safety valve11. System pressure gauge12. Water gauge 13. Water pressure switch14. Central heating thermostat control 15. Domestic hot water thermostat control16. Flow rate control 17. Electronic DHW flow rate18. By-pass (optional)19. Air pressure switch20. Fan

Electronic panel SM 30001 MINICODE®

1. On-off

2. CH temp.control 30-80°C

3. DHW temp.control. 35-65°C

4. Electronic thermometer

5. CH and DHW sonde

6. Safety thermostat

7. No ignition (Cut off)

8. Exhaust safety thermostat

Air pressure switch

9. No water into CH implant

10. On

Controls

Self diagnostic systemWith flash light

Electronic panel SM 30001 MINICODE®

• Self diagnostic system• Continuous flame modulation in CH - DHW • DHW temperature from 35° to 65°C• CH temperature from 30° to 80°C• Max power regulation• Low CH temperature• Antifrost system• Post circulation pump• No block pump safety• Late starting (for little implant)• Outside temperature • Automatic by-pass (optional)• Remote control system (optional)• IP X5D

Characteristics

Electronic panel SM 30001 MINICODE®

1 2 3 4

MA

XR

MIN

RL

A

SP

AZ

Selector1. Switch for max heating power “MAXR”

2. Switch for the min power “MIN”

3. Switch for step starting power “RLA”

4. Switch for 15 min. max power “SPAZ”

Electronic control SM 30001 MINICODE®

System – combi – storage boiler

Monothermic – Storage- Bithermic

DHW temperature selection

DHW no over pressure

CH temporized (3 minutes)

CH temperature selection

Natural gasLPG

A

B

C

D

E

F

G

NORDGASGas valve

• Motorized valve

• Ignition transformer separated

• Simple regulation

• Quiet work

• More sensibility, quick work

Gas valve

RadiantElectronic flow control

• Flow control with microprocessor, on from 0,2 bar

• Limescale protection

• Stainless steel filter

• Water rate control

Radiant electronic flow control

12 rampsBurner

•Multigas burner

•Very simple change mode:natural gas - LPG

•High efficiency

•Quiet mode

•Ionization flame control with electrode

12 ramps burner

BithermicExchanger

•Limescale control with NTC sondes

•6 thermic exchange passages

Bithermic exchanger

RadiantBithermic exchanger

Bithermic exchanger

Domestic Hot Water

Central Heating Water

No weld point

Case

Front and side insulating panel, for a lower noice level of working

Unsoundtrack

Exhaust control

Exhaust control

In the duct connection is present a disc where two holes does a simple mode of exhaust control

Dimensions

Thermostat with mechanical clock

Optional

Optional accessories

Remote LCD control

Outside temperature sonde

Mini 24

The future now